MIB Viewer

PRVT-INTERWORKING-OS-MIB

68 objects
The MIB enables display configuration of the device OS features.
OIDNameAccessStatusDescription
1.3.6.1.4.1.738.1.111Nodesoftware
1.3.6.1.4.1.738.1.111.1IdentityprvtInterworkOsMibThe MIB enables display configuration of the device OS features.
1.3.6.1.4.1.738.1.111.1.0NodeprvtInterworkOsNotifications
1.3.6.1.4.1.738.1.111.1.0.1NotificationimageCrcCheckFailedcurrentThe imageCrcCheckFailed notification indicates that the image loaded via TFTP has not passed the CRC check and has been discarded.
1.3.6.1.4.1.738.1.111.1.0.2NotificationconfigurationLoadFailedcurrentThe configurationLoadFailed notification indicates that the sending agent did not succeed to upload or download the configuration file.
1.3.6.1.4.1.738.1.111.1.0.3NotificationunauthorizedAccessViaCLIcurrentThe unauthorizedAccessViaCLI notification indicates that the last attempt to login to the device via CLI cannot be authorized.
1.3.6.1.4.1.738.1.111.1.0.4NotificationsnmpSetExecutedcurrentThis notification indicates that a successful set request has been performed.
1.3.6.1.4.1.738.1.111.1.0.5NotificationmanagementOptionSupportChangedcurrentThis notification indicates that a management option license has been changed.
1.3.6.1.4.1.738.1.111.1.1Nodeversion
1.3.6.1.4.1.738.1.111.1.1.1ScalarbootVersionNumberread-onlycurrentThis object identifies version number of the Boot program
1.3.6.1.4.1.738.1.111.1.1.2ScalarbootVersionDateread-onlycurrentThis object identifies creation date/time of the Boot program
1.3.6.1.4.1.738.1.111.1.1.3ScalarbootVersionStringread-onlycurrentThis object contains text for the current version of the Boot program
1.3.6.1.4.1.738.1.111.1.1.4ScalaroSversionNumberread-onlycurrentThis object identifies version number of the OS
1.3.6.1.4.1.738.1.111.1.1.5ScalaroSversionDateread-onlycurrentThis object identifies creation date/time of the OS
1.3.6.1.4.1.738.1.111.1.1.6ScalaroSversionStringread-onlycurrentThis object contains text for the current version of the OS
1.3.6.1.4.1.738.1.111.1.1.7ScalarappletVersionNumberread-onlycurrentThis object contains text for the current version of the embedded applet
1.3.6.1.4.1.738.1.111.1.1.8ScalarappletVersionDateread-onlycurrentThis object contains text for the creation date of the current embedded applet version
1.3.6.1.4.1.738.1.111.1.2Nodeoption
1.3.6.1.4.1.738.1.111.1.2.1ScalaroptionInstalledread-onlycurrentThis object identifies creation date/time of the OS
1.3.6.1.4.1.738.1.111.1.3Nodemanagement
1.3.6.1.4.1.738.1.111.1.3.1NodemanagementConnectivity
1.3.6.1.4.1.738.1.111.1.3.1.1ScalarmanagementConnectivityMACAddrread-onlycurrentGet the agent MAC address.
1.3.6.1.4.1.738.1.111.1.3.1.2ScalarmanagementConnectivityIpAddressread-writecurrentSet IP Address for the device.
1.3.6.1.4.1.738.1.111.1.3.1.3ScalarmanagementConnectivityIPNetMaskread-writecurrentSet IP NetMask for the device.
1.3.6.1.4.1.738.1.111.1.3.1.4ScalarmanagementIPGateAddressread-writecurrentSet Gateway Address for the device - only applies for devices without L3 capabilities.
1.3.6.1.4.1.738.1.111.1.3.1.5ScalarmanagementSerialBaudread-writecurrentThe Serial port BAUD Rate. Attributes are 8 Start Bits, no parity, and 1 stop bits (8N1) and Hardware Flow Control. Valid values are 2400, 9600, 19200, and 384…
1.3.6.1.4.1.738.1.111.1.3.2NodemanagementLoad
1.3.6.1.4.1.738.1.111.1.3.2.1ScalarmanagementLoadTftpServerAddressread-writecurrentSet IP Address for the TFTP server used for downloading and uploading files.
1.3.6.1.4.1.738.1.111.1.3.2.2ScalarmanagementLoadFileNameread-writecurrentSet TFTP file path and name.
1.3.6.1.4.1.738.1.111.1.3.2.3ScalarmanagementLoadTyperead-writecurrentThe type of file to download or upload upon a managementLoadExecute.
1.3.6.1.4.1.738.1.111.1.3.2.4ScalarmanagementLoadExecuteread-writecurrentExecute file download or upload procedure. A SET of this object starts the load procedure. Note that the Application and Boot images can only be downloaded. Th…
1.3.6.1.4.1.738.1.111.1.3.2.5ScalarmanagementLoadExecuteStatusread-onlycurrentProvides status on the execute file load procedure. The status return is given by one of the enumerated codes not-started (download has not yet started) in-pro…
1.3.6.1.4.1.738.1.111.1.3.3NodemanagementMisc
1.3.6.1.4.1.738.1.111.1.3.3.1ScalarmanagementMiscSaveToNvmread-writecurrentWhen set to save (2), all nonvolatile configuration parameters are saved to NVM (Nonvolatile Memory). NVM save operations may be slow (e.g., erasing/writing Fl…
1.3.6.1.4.1.738.1.111.1.3.3.2ScalarmanagementMiscResetread-writecurrentPhysically performs a hardware reset of the unit. Use with care. A reset (2) resets the unit, the reset-to-defaults (3) resets the configuration file to factor…
1.3.6.1.4.1.738.1.111.1.3.3.3ScalarmanagementMiscReloadread-writecurrentReload the unit software, the unit hardware will not be affected. A value of noop (1) is always returned for a GET operation.
1.3.6.1.4.1.738.1.111.1.3.3.4ScalarmanagementMiscReloadInTimeread-writecurrentIndicates time for scheduled reload without save in hour:min. octets contents range 1 day 0x01..0x1f (1-31) 2 month 0x01..0x0C (1..12) where january = 1 decemb…
1.3.6.1.4.1.738.1.111.1.3.3.5ScalarmanagementMiscReloadAtTimeread-writecurrentIndicates time for scheduled reload without save at day:month:hour:min. octets contents range 1 day 0x01..0x1f (1-31) 2 month 0x01..0x0C (1..12) where january …
1.3.6.1.4.1.738.1.111.1.3.3.6ScalarmanagementMiscReloadSaveInTimeread-writecurrentIndicates time for scheduled reload with save in hour:min. octets contents range 1 day 0x01..0x1f (1-31) 2 month 0x01..0x0C (1..12) where january = 1 december …
1.3.6.1.4.1.738.1.111.1.3.3.7ScalarmanagementMiscReloadSaveAtTimeread-writecurrentIndicates time for scheduled reload with save at day:month:hour:min. octets contents range 1 day 0x01..0x1f (1-31) 2 month 0x01..0x0C (1..12) where january = 1…
1.3.6.1.4.1.738.1.111.1.3.4NodemanagementLicense
1.3.6.1.4.1.738.1.111.1.3.4.1ScalarmanagementOptionSupportStatusread-onlycurrentIndicates active software support options (license).
1.3.6.1.4.1.738.1.111.1.3.4.2ScalarmanagementOptionSupportKeyread-writecurrentSpecify the software support option key (license). After set, device must be reloaded the new option to take affect.
1.3.6.1.4.1.738.1.111.1.3.4.3ScalarmanagementOptionSupportAddressaccessible-for-notifycurrentShows the address of SNMP NMS that has configured last the option.
1.3.6.1.4.1.738.1.111.1.3.4.4ScalarmanagementOptionSupportL3Capableread-onlycurrentIndicates if the swicth is capable for L3 features - true The switch is capable for L3 features - false The switch is not capable for L3 features
1.3.6.1.4.1.738.1.111.1.3.5NodeprvtBootConfigUpgrade
1.3.6.1.4.1.738.1.111.1.3.5.1ScalarprvtBootUpgradeSrcURIread-writecurrentThe object represents an address from where the application will be copied and used by the device. The address must be given in a valid URI format. It will be …
1.3.6.1.4.1.738.1.111.1.3.5.2ScalarprvtBootApplicationNameURIread-writecurrentThis object represents the name of the application to be used by the network device to boot. The name of the application is given in URI format to indicate the…
1.3.6.1.4.1.738.1.111.1.3.5.3ScalarprvtBootConfigURIread-writecurrentThis object represents the configuration file's name of a network device. The value must be set in URI format. It can point to either local or remote configura…
1.3.6.1.4.1.738.1.111.1.3.5.4ScalarprvtBootUpgradeCmdread-writecurrentThis field is used to apply the configuration. When a get request is executed, the returned value should be always ready. When apply(2) command is executed, th…
1.3.6.1.4.1.738.1.111.1.3.5.5ScalarprvtBootOperStatusread-onlycurrentThe object is used to show the current status of the upgrating process. The default value is ready(1), indicating that the process is idle. when the value is s…
1.3.6.1.4.1.738.1.111.1.3.5.6ScalarprvtBootErrorConditionread-onlycurrentThe object can be used for feedback. How the upgrading process have finished
1.3.6.1.4.1.738.1.111.1.4Nodecpu
1.3.6.1.4.1.738.1.111.1.4.1NodecpuMonitoring
1.3.6.1.4.1.738.1.111.1.4.1.1ScalarcpuMonitoringStatusread-writecurrentThe object shows the status of the CPU monitor
1.3.6.1.4.1.738.1.111.1.4.1.2ScalarcpuMonitoringUtilizationread-onlycurrentThe object shows the current CPU utilization
1.3.6.1.4.1.738.1.111.1.4.2NodecpuRedundancy
1.3.6.1.4.1.738.1.111.1.4.2.1ScalarcpuHwRedundancySupportread-onlycurrentThis object shows if the backplan of this unit support CPU redundancy.
1.3.6.1.4.1.738.1.111.1.4.2.2TablecpuRedundancyTablenot-accessiblecurrentThis table contains the CPU redundancy information.
1.3.6.1.4.1.738.1.111.1.4.2.2.1RowcpuRedundancyEntrynot-accessiblecurrentInformation about one CPU
1.3.6.1.4.1.738.1.111.1.4.2.2.1.1ColumncpuIdnot-accessiblecurrentThe ID of the CPU in the system
1.3.6.1.4.1.738.1.111.1.4.2.2.1.2ColumncpuNameread-onlycurrentTextual representation of the CPU
1.3.6.1.4.1.738.1.111.1.4.2.2.1.3ColumncpuStatusread-onlycurrentThe CPU status
1.3.6.1.4.1.738.1.111.1.4.2.2.1.4ColumncpuRedundancySupportread-onlycurrentThis object shows if the CPU card supports redundancy.
1.3.6.1.4.1.738.1.111.1.4.2.2.1.5ColumncpuSWVersionStringread-onlycurrentThe OS version currently running on the CPU
1.3.6.1.4.1.738.1.111.1.4.3NodecpuHW
1.3.6.1.4.1.738.1.111.1.4.3.1ScalarcpuRAMsizeread-onlycurrentThis object returns the CPU card RAM size
1.3.6.1.4.1.738.1.111.1.5NodeprvtInterworkOsConformance