PRVT-SYNC-ETHERNET-MIB
63 objects
This is the MIB module to manage synchronization over ethernet.
Imported Objects
| IF-MIB | ifIndex |
| PRVT-SWITCH-MIB | switch |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DateAndTime RowStatus TEXTUAL-CONVENTION TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.738.1.5.170 | IdentityprvtSyncEthernetMIB | This is the MIB module to manage synchronization over ethernet. | ||
| 1.3.6.1.4.1.738.1.5.170.0 | NodeprvtSyncEthernetMIBNotifications | |||
| 1.3.6.1.4.1.738.1.5.170.0.1 | NotificationsyncEthernetInvalidESMC | current | Invalid ESMC has been received. | |
| 1.3.6.1.4.1.738.1.5.170.0.2 | NotificationsyncEthernetQualityLevelChange | current | Current value of syncEthernetClockSourceQuality has been changed. | |
| 1.3.6.1.4.1.738.1.5.170.0.3 | NotificationsyncEthernetInvalidQualityLevelReceived | current | Invalid Quality level equals to QL-INVx has been received. | |
| 1.3.6.1.4.1.738.1.5.170.0.4 | NotificationsyncEthernetDPLLReferenceChange | current | DPLL's reference clock changed. | |
| 1.3.6.1.4.1.738.1.5.170.0.5 | NotificationsyncEthernetDPLLChanged | current | Some of the DPLL's operational status changes. | |
| 1.3.6.1.4.1.738.1.5.170.0.6 | NotificationsyncEthernetDPLLLockFailed | current | If after new Reference selection the DPLL can't lock onto it, this will affect the Clock Source associated with that reference | |
| 1.3.6.1.4.1.738.1.5.170.1 | NodeprvtSyncEthernetMIBObjects | |||
| 1.3.6.1.4.1.738.1.5.170.1.1 | ScalarsyncEthernetHoldOffTime | read-write | current | Timeout value, in millisseconds, for the hold-off timer. |
| 1.3.6.1.4.1.738.1.5.170.1.2 | ScalarsyncEthernetWaitToRestoreTime | read-write | current | Timeout value, in minutes, for the wait-to-restore timer. |
| 1.3.6.1.4.1.738.1.5.170.1.3 | ScalarsyncEthernetG781OptionMode | read-write | current | Specify which G.781 option mode to operate in. |
| 1.3.6.1.4.1.738.1.5.170.1.10 | TablesyncEthernetClockSourceTable | not-accessible | current | Source clock synchronization table. |
| 1.3.6.1.4.1.738.1.5.170.1.10.1 | RowsyncEthernetClockSourceEntry | not-accessible | current | Source clock synchronization entry. |
| 1.3.6.1.4.1.738.1.5.170.1.10.1.2 | ColumnsyncEthernetClockSourceRowStatus | read-create | current | Clock source synchronization table rowstatus. |
| 1.3.6.1.4.1.738.1.5.170.1.10.1.3 | ColumnsyncEthernetClockSourceAdminStatus | read-create | current | Enable clock source. |
| 1.3.6.1.4.1.738.1.5.170.1.10.1.4 | ColumnsyncEthernetClockSourceEsmc | read-create | current | Enable receiving ESMC messages (Synchronization Status Messages). Only applicable for BITS clock sources. |
| 1.3.6.1.4.1.738.1.5.170.1.10.1.5 | ColumnsyncEthernetClockSourceFrequency | read-create | current | Specify input frequency - N*8kHz Only applicable for BITS clock sources. |
| 1.3.6.1.4.1.738.1.5.170.1.10.1.6 | ColumnsyncEthernetClockSourceQuality | read-create | current | Specify quality level In G781-option I mode, valid values are prs, ssuA, ssuB, dnu. In G781-option II mode, valid values are stu, prs, tnc, st2, st3, smc, st3e… |
| 1.3.6.1.4.1.738.1.5.170.1.10.1.7 | ColumnsyncEthernetClockSourceQualityChangeNotify | read-create | current | Enable quality level change notifications |
| 1.3.6.1.4.1.738.1.5.170.1.10.1.8 | ColumnsyncEthernetClockSourceRecvQualityLevel | read-only | current | The received quality level value. |
| 1.3.6.1.4.1.738.1.5.170.1.10.1.9 | ColumnsyncEthernetClockSourceLastRecvEsmcPduTime | read-only | current | Time elapsed since the last valid ESMC message received |
| 1.3.6.1.4.1.738.1.5.170.1.10.1.10 | ColumnsyncEthernetClockSourceLastRecvEsmcErrorPduTime | read-only | current | Time elapsed since the last invalid ESMC message received |
| 1.3.6.1.4.1.738.1.5.170.1.10.1.11 | ColumnsyncEthernetClockSourceLastRecvEsmcPduType | read-only | current | Last received ESMC message type |
| 1.3.6.1.4.1.738.1.5.170.1.10.1.12 | ColumnsyncEthernetClockSourceLastRecvLastError | read-only | current | Last error code |
| 1.3.6.1.4.1.738.1.5.170.1.10.1.13 | ColumnsyncEthernetClockSourceNumRecvEsmcPdu | read-only | current | Total number of received ESMC messages |
| 1.3.6.1.4.1.738.1.5.170.1.10.1.14 | ColumnsyncEthernetClockSourceNumDiscEsmcPdu | read-only | current | Total number of discarded ESMC messages |
| 1.3.6.1.4.1.738.1.5.170.1.10.1.15 | ColumnsyncEthernetClockSourceNumSignalFail | read-only | current | Total number of generated signal failure events |
| 1.3.6.1.4.1.738.1.5.170.1.10.1.16 | ColumnsyncEthernetClockSourceQualityInvalidNotify | read-create | current | Enable invalid quality notifications |
| 1.3.6.1.4.1.738.1.5.170.1.10.1.17 | ColumnsyncEthernetClockSourceEsmcInvalidNotify | read-create | current | Enable invalid ESMC notifications |
| 1.3.6.1.4.1.738.1.5.170.1.12 | TablesyncEthernetClockOutputTable | not-accessible | current | Output clock synchronization table. |
| 1.3.6.1.4.1.738.1.5.170.1.12.1 | RowsyncEthernetClockOutputEntry | not-accessible | current | Output clock synchronization entry. |
| 1.3.6.1.4.1.738.1.5.170.1.12.1.2 | ColumnsyncEthernetClockOutputRowStatus | read-create | current | syncEthernetClockOutput table rowStatus |
| 1.3.6.1.4.1.738.1.5.170.1.12.1.3 | ColumnsyncEthernetClockOutputEsmc | read-create | current | Enable sending ESMC messages Only applicable for BITS clock outputs. |
| 1.3.6.1.4.1.738.1.5.170.1.12.1.4 | ColumnsyncEthernetClockOutputFrequency | read-create | current | Specify output frequency - N*8kHz Only applicable for BITS clock outputs. |
| 1.3.6.1.4.1.738.1.5.170.1.12.1.5 | ColumnsyncEthernetClockOutputDpll | read-create | current | Assign output clock to DPLL Only applicable for BITS clock outputs. Must be set to the syncEthernetDpllModuleId value of an existing row in syncEthernetDpllTab… |
| 1.3.6.1.4.1.738.1.5.170.1.12.1.6 | ColumnsyncEthernetClockOutputQualityLevel | read-only | current | Last quality level value sent |
| 1.3.6.1.4.1.738.1.5.170.1.12.1.7 | ColumnsyncEthernetClockOutputLastQualityLevelChange | read-only | current | Time elapsed since the last quality level change |
| 1.3.6.1.4.1.738.1.5.170.1.12.1.8 | ColumnsyncEthernetClockOutputMsgEvent | read-only | current | Last ESMC message type sent |
| 1.3.6.1.4.1.738.1.5.170.1.12.1.9 | ColumnsyncEthernetClockOutputNumTransmittedEsmcPdu | read-only | current | Total number of ESMC messages sent |
| 1.3.6.1.4.1.738.1.5.170.1.12.1.10 | ColumnsyncEthernetClockOutputNumTransmittedEventEsmcPdu | read-only | current | Total number of ESMC messages sent |
| 1.3.6.1.4.1.738.1.5.170.1.14 | TablesyncEthernetDpllTable | not-accessible | current | Synchronization DPLL table |
| 1.3.6.1.4.1.738.1.5.170.1.14.1 | RowsyncEthernetDpllEntry | not-accessible | current | Synchronization DPLL entry |
| 1.3.6.1.4.1.738.1.5.170.1.14.1.1 | ColumnsyncEthernetDpllModuleId | not-accessible | current | Synchronization DPLL module index |
| 1.3.6.1.4.1.738.1.5.170.1.14.1.2 | ColumnsyncEthernetDpllRowStatus | read-create | current | Synchronization DPLL rowstatus |
| 1.3.6.1.4.1.738.1.5.170.1.14.1.3 | ColumnsyncEthernetDpllAdminStatus | read-create | current | Administrative status of the DPLL |
| 1.3.6.1.4.1.738.1.5.170.1.14.1.4 | ColumnsyncEthernetDpllReferenceSelection | read-create | current | Specify reference selection mode |
| 1.3.6.1.4.1.738.1.5.170.1.14.1.5 | ColumnsyncEthernetDpllEnableQualityLevel | read-create | current | Enable reference selection based on quality level Only applicable when syncEthernetDpllReferenceSelection equals g781. |
| 1.3.6.1.4.1.738.1.5.170.1.14.1.6 | ColumnsyncEthernetDpllStatusChangeNotify | read-create | current | Enable DPLL status change notifications |
| 1.3.6.1.4.1.738.1.5.170.1.14.1.7 | ColumnsyncEthernetDpllReferenceChangeNotify | read-create | current | Enable reference clock change notifications |
| 1.3.6.1.4.1.738.1.5.170.1.14.1.8 | ColumnsyncEthernetDpllStatus | read-only | current | DPLL operational status |
| 1.3.6.1.4.1.738.1.5.170.1.14.1.9 | ColumnsyncEthernetDpllStatusLastChange | read-only | current | Time since last DPLL status change |
| 1.3.6.1.4.1.738.1.5.170.1.14.1.10 | ColumnsyncEthernetDpllSystemQualityLevel | read-only | current | System quality level |
| 1.3.6.1.4.1.738.1.5.170.1.14.1.11 | ColumnsyncEthernetDpllSystemQualityLevelLastChange | read-only | current | Time since last system quality level change |
| 1.3.6.1.4.1.738.1.5.170.1.14.1.12 | ColumnsyncEthernetDpllSelectedReferenceClock | read-only | current | The selected reference clock source |
| 1.3.6.1.4.1.738.1.5.170.1.14.1.13 | ColumnsyncEthernetDpllSelectedReferenceClockChange | read-only | current | Time since last reference clock change |
| 1.3.6.1.4.1.738.1.5.170.1.16 | TablesyncEthernetDpllClkRefTable | not-accessible | current | Synchronization DPLL clock reference table |
| 1.3.6.1.4.1.738.1.5.170.1.16.1 | RowsyncEthernetDpllClkRefEntry | not-accessible | current | Synchronization DPLL clock reference entry |
| 1.3.6.1.4.1.738.1.5.170.1.16.1.2 | ColumnsyncEthernetDpllClkRefRowStatus | read-create | current | Synchronization DPLL clock reference rowstatus |
| 1.3.6.1.4.1.738.1.5.170.1.16.1.3 | ColumnsyncEthernetDpllClkRefPriority | read-create | current | Specify reference clock priority |
| 1.3.6.1.4.1.738.1.5.170.1.16.1.4 | ColumnsyncEthernetDpllClkRefLockOut | read-create | current | Lock reference clock |
| 1.3.6.1.4.1.738.1.5.170.1.16.1.5 | ColumnsyncEthernetDpllClkRefFailStatus | read-only | current | DPLL reference clock status |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| PrvtSyncEthernetQualityLevelType | INTEGER { prc(2), ssuA(4), ssuB(8), sec(11), dnu(15), stu(16), prs(17), tnc(20), st2(23), st3(26), smc(28), st3e(29), prov(30), dus(31), invalid(64), failed(65) } | current | Clock Quality Levels. |