PoE-MIB
44 objects
The Structure of PoE management for the proprietary enterprise.
Imported Objects
| DLINK-ID-REC-MIB | dlink-common-mgmt |
| RFC1213-MIB | DisplayString |
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-SMI | MODULE-IDENTITY OBJECT-TYPE |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.171.12.24 | IdentityswPoEMIB | The Structure of PoE management for the proprietary enterprise. | ||
| 1.3.6.1.4.1.171.12.24.1 | NodeswPoESystemCtrl | |||
| 1.3.6.1.4.1.171.12.24.1.1 | ScalarswPoESystemPowerLimit | read-write | current | The power budget (in watts) of the PoE sytem. |
| 1.3.6.1.4.1.171.12.24.1.2 | ScalarswPoESystemPowerDisconnectMethod | read-write | current | The power management disconnection method. When the total consumed power exceeds the power budget, the PoE controller initiates port disconnection, to prevent … |
| 1.3.6.1.4.1.171.12.24.1.3 | ScalarswPoESystemManagementMode | read-write | current | This mode can be either power_limit mode or auto mode. power_limit: If power supplied to the port exceeds the power limit specified for it, this port will be s… |
| 1.3.6.1.4.1.171.12.24.1.4 | ScalarswPoESystemLedMode | read-write | current | Specifies if the system mode will be POE or NORMAL. |
| 1.3.6.1.4.1.171.12.24.1.6 | ScalarswPoESystemCtrlLegacyPD | read-write | current | The legacy PD detection state. Enables or disables legacy PD detection on all PoE port. |
| 1.3.6.1.4.1.171.12.24.1.11 | TableswPoESystemStackingCtrlTable | not-accessible | current | A table that is used to configure PoE system information based on Unit ID. The Unit ID is used for stacking. |
| 1.3.6.1.4.1.171.12.24.1.11.1 | RowswPoESystemStackingCtrlEntry | not-accessible | current | A list of PoE system information based on Unit ID. |
| 1.3.6.1.4.1.171.12.24.1.11.1.1 | ColumnswPoESystemStackingCtrlUnitId | read-only | current | This object indicates the device's Unit ID. A unit ID of zero denotes a stand-alone device. |
| 1.3.6.1.4.1.171.12.24.1.11.1.2 | ColumnswPoESystemStackingCtrlPowerLimit | read-write | current | The power budget (in watts) of the PoE sytem. |
| 1.3.6.1.4.1.171.12.24.1.11.1.3 | ColumnswPoESystemStackingCtrlPowerDisconnectMethod | read-write | current | The power management disconnection method. When the total consumed power exceeds the power budget, the PoE controller initiates port disconnection to prevent o… |
| 1.3.6.1.4.1.171.12.24.1.11.1.4 | ColumnswPoESystemStackingCtrlManagementMode | read-write | current | This mode can be either power_limit mode or auto mode. power_limit: If power supplied to the port exceeds the power limit specified for it, this port will be s… |
| 1.3.6.1.4.1.171.12.24.1.11.1.5 | ColumnswPoESystemStackingCtrlLedMode | read-write | current | Specifies the system mode to be POE or NORMAL. |
| 1.3.6.1.4.1.171.12.24.1.11.1.6 | ColumnswPoESystemStackingCtrlLegacyPD | read-write | current | The legacy PD detection state. Enables or disables legacy PD detection on PoE unit. |
| 1.3.6.1.4.1.171.12.24.2 | NodeswPoESystemInfo | |||
| 1.3.6.1.4.1.171.12.24.2.1 | TableswPoESystemInfoTable | not-accessible | current | A table that contains PoE system information based on Unit ID. The Unit ID is used for stacking. |
| 1.3.6.1.4.1.171.12.24.2.1.1 | RowswPoESystemInfoEntry | not-accessible | current | A list of PoE system information based on Unit ID. |
| 1.3.6.1.4.1.171.12.24.2.1.1.1 | ColumnswPoESystemInfoUnitId | read-only | current | This object indicates the device's Unit ID. A unit ID of zero denotes a stand-alone device. |
| 1.3.6.1.4.1.171.12.24.2.1.1.2 | ColumnswPoESystemInfoPowerConsumption | read-only | current | The actual momentary power consumption (in watts) in the PoE system. |
| 1.3.6.1.4.1.171.12.24.2.1.1.3 | ColumnswPoESystemInfoPowerRemained | read-only | current | The actual momentary remaining power (in watts) in the PoE system. |
| 1.3.6.1.4.1.171.12.24.2.1.1.4 | ColumnswPoESystemInfoPowerLimit | read-only | current | The power budget (in watts) of the PoE sytem. |
| 1.3.6.1.4.1.171.12.24.2.1.1.5 | ColumnswPoESystemInfoPowerDisconnectMethod | read-only | current | The power management disconnection method. When the total consumed power exceeds the power budget, the PoE controller initiates port disconnection to prevent o… |
| 1.3.6.1.4.1.171.12.24.2.1.1.6 | ColumnswPoESystemInfoManagementMode | read-only | current | This mode can be either power_limit mode or auto mode. power_limit: If power supplied to the port exceeds the power limit specified for it, this port will be s… |
| 1.3.6.1.4.1.171.12.24.2.1.1.7 | ColumnswPoESystemInfoLegacyPD | read-only | current | The current status of legacy PD detection. |
| 1.3.6.1.4.1.171.12.24.3 | NodeswPoEPortCtrl | |||
| 1.3.6.1.4.1.171.12.24.3.1 | TableswPoEPortCtrlTable | not-accessible | current | A table that contains PoE configuration about every port in this stack. If a device has N ports, then the 1 N+1 2N+1 ...... |
| 1.3.6.1.4.1.171.12.24.3.1.1 | RowswPoEPortCtrlEntry | not-accessible | current | A list of PoE configurations for each port of the device in this stack. |
| 1.3.6.1.4.1.171.12.24.3.1.1.1 | ColumnswPoEPortCtrlPortIndex | read-only | current | This object indicates the devices' port number in this stack. If a device has N ports, then the 1 N+1 2N+1 ...... |
| 1.3.6.1.4.1.171.12.24.3.1.1.2 | ColumnswPoEPortCtrlState | read-write | current | The PoE port state. Enables or disables the PoE function on the specific port. The default setting is enable. |
| 1.3.6.1.4.1.171.12.24.3.1.1.3 | ColumnswPoEPortCtrlPriority | read-write | current | The PoE port priority. Port priority affects power-up order (after a rest, the ports are powered up according to their priority) and shutdown order (when excee… |
| 1.3.6.1.4.1.171.12.24.3.1.1.4 | ColumnswPoEPortCtrlPowerLimit | read-write | current | There are 4 pre-defined values for users' convenience to set the upper power limit for class 0, class 1, class 2, and class 3. class_0: 15400mW (The maximum po… |
| 1.3.6.1.4.1.171.12.24.3.1.1.5 | ColumnswPoEPortCtrlUserDefined | read-write | current | User defined per-port power limit (in milliwatts). If a port exceeds 10% of its power limit, the PoE system will shut down that port. The default setting is 15… |
| 1.3.6.1.4.1.171.12.24.3.1.1.6 | ColumnswPoEPortCtrlTimeRangeName | read-write | current | Specifies the time_range that applies to the port of the POE.If time range is configured, power can only be supplied during the period specified by the time ra… |
| 1.3.6.1.4.1.171.12.24.4 | NodeswPoEPortInfo | |||
| 1.3.6.1.4.1.171.12.24.4.1 | TableswPoEPortInfoTable | not-accessible | current | A table that contains PoE information about every port in this stack. If a device has N ports, then the 1 N+1 2N+1 ...... |
| 1.3.6.1.4.1.171.12.24.4.1.1 | RowswPoEPortInfoEntry | not-accessible | current | A list of PoE information for each port of the device in this stack. |
| 1.3.6.1.4.1.171.12.24.4.1.1.1 | ColumnswPoEPortInfoPortIndex | read-only | current | This object indicates the devices' port number in this stack. If a device has N ports, then the 1 N+1 2N+1 ...... |
| 1.3.6.1.4.1.171.12.24.4.1.1.2 | ColumnswPoEPortInfoClass | read-only | current | The power class of the PD according to 802.3af definitions: class 0: PD power consumption is within 0.44-12.95 watts, class 1: PD power consumption is within 0… |
| 1.3.6.1.4.1.171.12.24.4.1.1.3 | ColumnswPoEPortInfoPower | read-only | current | The port power consumption (in milliwatts). |
| 1.3.6.1.4.1.171.12.24.4.1.1.4 | ColumnswPoEPortInfoVoltage | read-only | current | The port input line voltage (in decivolts). |
| 1.3.6.1.4.1.171.12.24.4.1.1.5 | ColumnswPoEPortInfoCurrent | read-only | current | The port current (calculated in milliamps). |
| 1.3.6.1.4.1.171.12.24.4.1.1.6 | ColumnswPoEPortInfoStatus | read-only | current | The string describes the PoE port current status. |
| 1.3.6.1.4.1.171.12.24.4.1.1.7 | ColumnswpoEPortInfoLedStatus | read-only | current | The LED display for PoE port status. on (1): power is provided to the port on which a 802.3af-compliant or legacy PD is connected, off(2): no power is provided… |