PowerNet-MIB
7521 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | enterprises Gauge IpAddress TimeTicks |
| RFC1213-MIB | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.3 | Nodeexperimental | |||
| 1.3.6.1.4.1.318 | Nodeapc | |||
| 1.3.6.1.4.1.318.1 | NodecommunicationLost | SEVERE: Communication to the UPS has been lost. Steps to reestablish communication are in progress. | ||
| 1.3.6.1.4.1.318.1 | Nodeproducts | |||
| 1.3.6.1.4.1.318.1.1 | Nodehardware | |||
| 1.3.6.1.4.1.318.1.1.1 | Nodeups | |||
| 1.3.6.1.4.1.318.1.1.1.1 | NodeupsIdent | |||
| 1.3.6.1.4.1.318.1.1.1.1.1 | NodeupsBasicIdent | |||
| 1.3.6.1.4.1.318.1.1.1.1.1.1 | ScalarupsBasicIdentModel | read-only | mandatory | The UPS model name (e.g. 'APC Smart-UPS 600'). |
| 1.3.6.1.4.1.318.1.1.1.1.1.2 | ScalarupsBasicIdentName | read-write | mandatory | An 8 byte ID string identifying the UPS. This object can be set by the administrator. |
| 1.3.6.1.4.1.318.1.1.1.1.2 | NodeupsAdvIdent | |||
| 1.3.6.1.4.1.318.1.1.1.1.2.1 | ScalarupsAdvIdentFirmwareRevision | read-only | mandatory | The firmware revision of the UPS system's microprocessor. |
| 1.3.6.1.4.1.318.1.1.1.1.2.2 | ScalarupsAdvIdentDateOfManufacture | read-only | mandatory | The date when the UPS was manufactured in mm/dd/yy (or yyyy) format. |
| 1.3.6.1.4.1.318.1.1.1.1.2.3 | ScalarupsAdvIdentSerialNumber | read-only | mandatory | An 8-character string identifying the serial number of the UPS internal microprocessor. This number is set at the factory. NOTE: This number does NOT correspon… |
| 1.3.6.1.4.1.318.1.1.1.1.2.4 | ScalarupsAdvIdentFirmwareRevision2 | read-only | mandatory | The firmware revision of a UPS system co-microprocessor. |
| 1.3.6.1.4.1.318.1.1.1.1.2.5 | ScalarupsAdvIdentSkuNumber | read-only | mandatory | The SKU number of a UPS system. |
| 1.3.6.1.4.1.318.1.1.1.1.2.6 | ScalarupsAdvIdentHardwareRevision | read-only | mandatory | The hardware revision of a UPS system. |
| 1.3.6.1.4.1.318.1.1.1.2 | NodeupsBattery | |||
| 1.3.6.1.4.1.318.1.1.1.2.1 | NodeupsBasicBattery | |||
| 1.3.6.1.4.1.318.1.1.1.2.1.1 | ScalarupsBasicBatteryStatus | read-only | mandatory | The status of the UPS batteries. A batteryLow(3) value indicates the UPS will be unable to sustain the current load, and its services will be lost if power is … |
| 1.3.6.1.4.1.318.1.1.1.2.1.2 | ScalarupsBasicBatteryTimeOnBattery | read-only | mandatory | The elapsed time since the UPS has switched to battery power. |
| 1.3.6.1.4.1.318.1.1.1.2.1.3 | ScalarupsBasicBatteryLastReplaceDate | read-write | mandatory | The date when the UPS system's batteries were last replaced in mm/dd/yy (or yyyy) format. For Smart-UPS models, this value is originally set in the factory. Wh… |
| 1.3.6.1.4.1.318.1.1.1.2.2 | NodeupsAdvBattery | |||
| 1.3.6.1.4.1.318.1.1.1.2.2.1 | ScalarupsAdvBatteryCapacity | read-only | mandatory | The remaining battery capacity expressed in percent of full capacity. |
| 1.3.6.1.4.1.318.1.1.1.2.2.2 | ScalarupsAdvBatteryTemperature | read-only | mandatory | The current internal UPS temperature expressed in Celsius. |
| 1.3.6.1.4.1.318.1.1.1.2.2.3 | ScalarupsAdvBatteryRunTimeRemaining | read-only | mandatory | The UPS battery run time remaining before battery exhaustion. |
| 1.3.6.1.4.1.318.1.1.1.2.2.4 | ScalarupsAdvBatteryReplaceIndicator | read-only | mandatory | Indicates whether the UPS batteries need replacing. |
| 1.3.6.1.4.1.318.1.1.1.2.2.5 | ScalarupsAdvBatteryNumOfBattPacks | read-only | mandatory | The number of external battery packs connected to the UPS. If the UPS does not use smart cells then the agent reports ERROR_NO_SUCH_NAME. |
| 1.3.6.1.4.1.318.1.1.1.2.2.6 | ScalarupsAdvBatteryNumOfBadBattPacks | read-only | mandatory | The number of external battery packs connected to the UPS that are defective. If the UPS does not use smart cells then the agent reports ERROR_NO_SUCH_NAME. |
| 1.3.6.1.4.1.318.1.1.1.2.2.7 | ScalarupsAdvBatteryNominalVoltage | read-only | mandatory | The nominal battery voltage in Volts. |
| 1.3.6.1.4.1.318.1.1.1.2.2.8 | ScalarupsAdvBatteryActualVoltage | read-only | mandatory | The actual battery bus voltage in Volts. |
| 1.3.6.1.4.1.318.1.1.1.2.2.9 | ScalarupsAdvBatteryCurrent | read-only | mandatory | The battery current in Amps. |
| 1.3.6.1.4.1.318.1.1.1.2.2.10 | ScalarupsAdvTotalDCCurrent | read-only | mandatory | The total DC current in Amps. |
| 1.3.6.1.4.1.318.1.1.1.2.2.11 | ScalarupsAdvBatteryFullCapacity | read-only | mandatory | The full chargeable capacity of the battery which is expressed in percentage. |
| 1.3.6.1.4.1.318.1.1.1.2.2.12 | TableupsAdvBatteryActualVoltageTable | not-accessible | mandatory | A list of battery table entries. The number of battery frames present in UPS. |
| 1.3.6.1.4.1.318.1.1.1.2.2.12.1 | RowupsAdvBatteryActualVoltageEntry | not-accessible | mandatory | Information applicable to each of the Battery frames. |
| 1.3.6.1.4.1.318.1.1.1.2.2.12.1.1 | ColumnupsAdvBatteryActualVoltageTableIndex | read-only | mandatory | The Battery Frame identifier. Battery Frame index. |
| 1.3.6.1.4.1.318.1.1.1.2.2.12.1.2 | ColumnupsAdvBatteryActualVoltagePolarity | read-only | mandatory | The selected Battery Voltage Polarity. 0 indicates positive polarity. 1 indicates negative polarity. |
| 1.3.6.1.4.1.318.1.1.1.2.2.12.1.3 | ColumnupsAdvBatteryFrameActualVoltage | read-only | mandatory | The actual battery bus voltage in Volts. |
| 1.3.6.1.4.1.318.1.1.1.2.2.13 | TableupsAdvTotalDCCurrentTable | not-accessible | mandatory | A list of Battery Frame table entries. The number of entries is given by the value of Number of Battery Frames. |
| 1.3.6.1.4.1.318.1.1.1.2.2.13.1 | RowupsAdvTotalDCCurrentEntry | not-accessible | mandatory | An entry containing information applicable to a particular Battery Frame. |
| 1.3.6.1.4.1.318.1.1.1.2.2.13.1.1 | ColumnupsAdvTotalDCCurrentTableIndex | read-only | mandatory | The Battery Frame identifier. Total DC Current Table Index. |
| 1.3.6.1.4.1.318.1.1.1.2.2.13.1.2 | ColumnupsAdvTotalDCCurrentPolarity | read-only | mandatory | The selected Battery Current Polarity. 0 indicates positive polarity. 1 indicates negative polarity. |
| 1.3.6.1.4.1.318.1.1.1.2.2.13.1.3 | ColumnupsAdvTotalFrameDCCurrent | read-only | mandatory | The Total DC Current of battery in Amperes. |
| 1.3.6.1.4.1.318.1.1.1.2.2.14 | TableupsAdvBatteryCurrentTable | not-accessible | mandatory | A list of Battery Frame table entries. The number of entries is given by number of Battery frames present. |
| 1.3.6.1.4.1.318.1.1.1.2.2.14.1 | RowupsAdvBatteryCurrentEntry | not-accessible | mandatory | An entry containing information applicable to a particular battery frame. |
| 1.3.6.1.4.1.318.1.1.1.2.2.14.1.1 | ColumnupsAdvBatteryCurrentTableIndex | read-only | mandatory | The Battery Frame identifier. Battery Current Table Index. |
| 1.3.6.1.4.1.318.1.1.1.2.2.14.1.2 | ColumnupsAdvBatteryCurrentIndex | read-only | mandatory | The battery frame identifier. |
| 1.3.6.1.4.1.318.1.1.1.2.2.14.1.3 | ColumnupsAdvBatteryCurrentPolarity | read-only | mandatory | The selected Battery current polarity. 0 indicates positive polarity. 1 indicates negative polarity |
| 1.3.6.1.4.1.318.1.1.1.2.2.14.1.4 | ColumnupsAdvBatteryFrameCurrent | read-only | mandatory | The Battery current measured in Amperes |
| 1.3.6.1.4.1.318.1.1.1.2.2.15 | ScalarupsAdvBatteryEstimatedChargeTime | read-only | mandatory | The estimated remaining time required to charge the UPS to a full state of charge. |
| 1.3.6.1.4.1.318.1.1.1.2.2.16 | ScalarupsAdvBatteryPower | read-only | mandatory | The measured battery power in kW. |
| 1.3.6.1.4.1.318.1.1.1.2.2.17 | ScalarupsAdvBatteryChargerStatus | read-only | mandatory | The status of the battery charger. If the UPS is unable to find the state of charger, this variable is set to unknown(1). |
| 1.3.6.1.4.1.318.1.1.1.2.2.19 | ScalarupsAdvBatteryInternalSKU | read-only | mandatory | The SKU of the internal battery. |
| 1.3.6.1.4.1.318.1.1.1.2.2.20 | ScalarupsAdvBatteryExternalSKU | read-only | mandatory | The SKU of the external battery. |
| 1.3.6.1.4.1.318.1.1.1.2.2.21 | ScalarupsAdvBatteryRecommendedReplaceDate | read-only | mandatory | The recommended replacement date for the battery based on the UPS internal battery life algorithm. |
| 1.3.6.1.4.1.318.1.1.1.2.2.22 | ScalarupsAdvBatteryNominalBackupTime | read-only | mandatory | Defines the runtime of the user supplied battery in minutes, when battery is new. |
| 1.3.6.1.4.1.318.1.1.1.2.2.23 | ScalarupsAdvBatteryCondition | read-only | mandatory | Health of the battries based on the battery test. |
| 1.3.6.1.4.1.318.1.1.1.2.2.24 | ScalarupsAdvBatteryChargingCurrentRestricted | read-only | mandatory | Indicates whether battery charging current is restricted or not. The value of yes(1) indicates that battery charging current is restricted . The value of no(2)… |
| 1.3.6.1.4.1.318.1.1.1.2.3 | NodeupsHighPrecBattery | |||
| 1.3.6.1.4.1.318.1.1.1.2.3.1 | ScalarupsHighPrecBatteryCapacity | read-only | mandatory | The remaining battery capacity expressed in tenths of percent of full capacity. |
| 1.3.6.1.4.1.318.1.1.1.2.3.2 | ScalarupsHighPrecBatteryTemperature | read-only | mandatory | The current internal UPS temperature expressed in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.1.2.3.3 | ScalarupsHighPrecBatteryNominalVoltage | read-only | mandatory | The nominal battery voltage in tenths of Volts. |
| 1.3.6.1.4.1.318.1.1.1.2.3.4 | ScalarupsHighPrecBatteryActualVoltage | read-only | mandatory | The actual battery bus voltage in tenths of Volts. |
| 1.3.6.1.4.1.318.1.1.1.2.3.5 | ScalarupsHighPrecBatteryCurrent | read-only | mandatory | The battery current in tenths of Amps. |
| 1.3.6.1.4.1.318.1.1.1.2.3.6 | ScalarupsHighPrecTotalDCCurrent | read-only | mandatory | The total DC current in tenths of Amps. |
| 1.3.6.1.4.1.318.1.1.1.2.3.7 | TableupsHighPrecBatteryActualVoltageTable | not-accessible | mandatory | A list of Battery frame table entries. The number of entries is given by the number of Battery frames. |
| 1.3.6.1.4.1.318.1.1.1.2.3.7.1 | RowupsHighPrecBatteryActualVoltageEntry | not-accessible | mandatory | An entry containing information applicable to a particular battery frame. |
| 1.3.6.1.4.1.318.1.1.1.2.3.7.1.1 | ColumnupsHighPrecBatteryActualVoltageTableIndex | read-only | mandatory | The Battery Frame identifier. High Precision Actual Voltage Table Index. |
| 1.3.6.1.4.1.318.1.1.1.2.3.7.1.2 | ColumnupsHighPrecBatteryActualVoltagePolarity | read-only | mandatory | The selected Battery Voltage polarity. 0 indicates positive polarity. 1 indicates negative polarity. |
| 1.3.6.1.4.1.318.1.1.1.2.3.7.1.3 | ColumnupsHighPrecBatteryVoltage | read-only | mandatory | The actual battery bus voltage expressed as tenths of Volts. |
| 1.3.6.1.4.1.318.1.1.1.2.3.8 | TableupsHighPrecTotalDCCurrentTable | not-accessible | mandatory | A list of Battery Frame table entries. The number of entries is given by the number of battery frames. |
| 1.3.6.1.4.1.318.1.1.1.2.3.8.1 | RowupsHighPrecTotalDCCurrentEntry | not-accessible | mandatory | An entry containing information applicable to a particular battery frame. |
| 1.3.6.1.4.1.318.1.1.1.2.3.8.1.1 | ColumnupsHighPrecTotalDCCurrentTableIndex | read-only | mandatory | The Battery Frame identifier. High precision Total DC Current index. |
| 1.3.6.1.4.1.318.1.1.1.2.3.8.1.2 | ColumnupsHighPrecTotalDCCurrentPolarity | read-only | mandatory | The selected Battery Current polarity. 0 indicates positive polarity. 1 indicates negative polarity. |
| 1.3.6.1.4.1.318.1.1.1.2.3.8.1.3 | ColumnupsHighPrecTotalDCFrameCurrent | read-only | mandatory | The total DC current in tenths of Amperes. |
| 1.3.6.1.4.1.318.1.1.1.2.3.9 | TableupsHighPrecBatteryCurrentTable | not-accessible | mandatory | A list of Battery Frame table entries. The number of entries is given by the number of battery frames. |
| 1.3.6.1.4.1.318.1.1.1.2.3.9.1 | RowupsHighPrecBatteryCurrentEntry | not-accessible | mandatory | An entry containing information applicable to a particular battery frame. |
| 1.3.6.1.4.1.318.1.1.1.2.3.9.1.1 | ColumnupsHighPrecBatteryCurrentTableIndex | read-only | mandatory | The Battery frame identifier. Battery Frame index. |
| 1.3.6.1.4.1.318.1.1.1.2.3.9.1.2 | ColumnupsHighPrecBatteryCurrentIndex | read-only | mandatory | The Battery frame identifier. Battery Index for each frame. |
| 1.3.6.1.4.1.318.1.1.1.2.3.9.1.3 | ColumnupsHighPrecBatteryCurrentPolarity | read-only | mandatory | The selected Battery Current polarity. 0 indicates positive polarity. 1 indicates negative polarity. |
| 1.3.6.1.4.1.318.1.1.1.2.3.9.1.4 | ColumnupsHighPrecBatteryFrameCurrent | read-only | mandatory | The Battery current in tenths of Amperes. |
| 1.3.6.1.4.1.318.1.1.1.2.3.10 | NodeupsHighPrecBatteryPacks | |||
| 1.3.6.1.4.1.318.1.1.1.2.3.10.1 | ScalarupsHighPrecBatteryPackTableSize | read-only | mandatory | The number of entries in the upsHighPrecBatteryPacks. |
| 1.3.6.1.4.1.318.1.1.1.2.3.10.2 | TableupsHighPrecBatteryPackTable | not-accessible | mandatory | A list of Battery Pack table entries. The number of entries is given by number of Battery Packs present. |
| 1.3.6.1.4.1.318.1.1.1.2.3.10.2.1 | RowupsHighPrecBatteryPackEntry | not-accessible | mandatory | An entry containing information applicable to a particular battery pack. |
| 1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.1 | ColumnupsHighPrecBatteryPackIndex | read-only | mandatory | The battery pack identifier. |
| 1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.2 | ColumnupsHighPrecBatteryCartridgeIndex | read-only | mandatory | The battery cartridge identifier. |
| 1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.3 | ColumnupsHighPrecBatteryPackFirmwareRevision | read-only | mandatory | The battery pack firmware revision. |
| 1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.4 | ColumnupsHighPrecBatteryPackSerialNumber | read-only | mandatory | The battery pack serial number. |
| 1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.5 | ColumnupsHighPrecBatteryPackTemperature | read-only | mandatory | The battery pack temperature measured in 10ths of degree Celcius |
| 1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.6 | ColumnupsHighPrecBatteryPackStatus | read-only | mandatory | The battery status for the pack only. bit 0 Disconnected bit 1 Overvoltage bit 2 NeedsReplacement bit 3 OvertemperatureCritical bit 4 Charger bit 5 Temperature… |
| 1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.7 | ColumnupsHighPrecBatteryPackCartridgeHealth | read-only | mandatory | The battery cartridge health. bit 0 Battery lifetime okay bit 1 Battery lifetime near end, order replacement cartridge bit 2 Battery lifetime exceeded, replace… |
| 1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.8 | ColumnupsHighPrecBatteryPackCartridgeReplaceDate | read-only | mandatory | The battery cartridge estimated battery replace date. |
| 1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.9 | ColumnupsHighPrecBatteryPackCartridgeInstallDate | read-write | mandatory | The battery cartridge install date. |
| 1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.10 | ColumnupsHighPrecBatteryPackCartridgeStatus | read-only | mandatory | The battery cartridge status. bit 0 Disconnected bit 1 Overvoltage bit 2 NeedsReplacement bit 3 OvertemperatureCritical bit 4 Charger bit 5 TemperatureSensor b… |
| 1.3.6.1.4.1.318.1.1.1.2.3.10.3 | ScalarupsHighPrecBatteryPackOnlyTableSize | read-only | mandatory | The number of entries in the upsHighPrecBatteryPacks. |
| 1.3.6.1.4.1.318.1.1.1.2.3.10.4 | TableupsHighPrecBatteryPackOnlyTable | not-accessible | mandatory | A list of Battery Pack table entries. The number of entries is given by number of Battery Packs present. |
| 1.3.6.1.4.1.318.1.1.1.2.3.10.4.1 | RowupsHighPrecBatteryPackOnlyEntry | not-accessible | mandatory | An entry containing information applicable to a particular battery pack. |
| 1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.1 | ColumnupsHighPrecBatteryPackOnlyIndex | read-only | mandatory | The battery pack identifier. |
| 1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.2 | ColumnupsHighPrecBatteryPackOnlyFirmwareRevision | read-only | mandatory | The battery pack firmware revision. |
| 1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.3 | ColumnupsHighPrecBatteryPackOnlySerialNumber | read-only | mandatory | The battery pack serial number. |
| 1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.4 | ColumnupsHighPrecBatteryPackOnlyTemperature | read-only | mandatory | The battery pack temperature measured in 10ths of degree Celcius |
| 1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.5 | ColumnupsHighPrecBatteryPackOnlyStatus | read-only | mandatory | The battery status for the pack only. bit 0 Disconnected bit 1 Overvoltage bit 2 NeedsReplacement bit 3 OvertemperatureCritical bit 4 Charger bit 5 Temperature… |
| 1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.6 | ColumnupsHighPrecBatteryPackOnlyHealth | read-only | mandatory | The battery pack health. bit 0 Battery lifetime okay bit 1 Battery lifetime near end, order replacement pack bit 2 Battery lifetime exceeded, replace battery b… |
| 1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.7 | ColumnupsHighPrecBatteryPackOnlyReplaceDate | read-only | mandatory | The battery pack estimated battery replace date. |
| 1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.8 | ColumnupsHighPrecBatteryPackOnlyInstallDate | read-write | mandatory | The battery pack install date. |
| 1.3.6.1.4.1.318.1.1.1.2.3.11 | ScalarupsHighPrecBatteryHealth | read-only | mandatory | The battery health. Bit 0 Battery life okay Bit 1 Battery life near end, order battery cartridge Bit 2 Battery life exceeded, replace battery cartridge Bit 3 B… |
| 1.3.6.1.4.1.318.1.1.1.3 | NodeupsInput | |||
| 1.3.6.1.4.1.318.1.1.1.3.1 | NodeupsBasicInput | |||
| 1.3.6.1.4.1.318.1.1.1.3.1.1 | ScalarupsBasicInputPhase | read-only | mandatory | The current AC input phase. |
| 1.3.6.1.4.1.318.1.1.1.3.2 | NodeupsAdvInput | |||
| 1.3.6.1.4.1.318.1.1.1.3.2.1 | ScalarupsAdvInputLineVoltage | read-only | mandatory | The current utility line voltage in VAC. |
| 1.3.6.1.4.1.318.1.1.1.3.2.2 | ScalarupsAdvInputMaxLineVoltage | read-only | mandatory | The maximum utility line voltage in VAC over the previous 1 minute period. |
| 1.3.6.1.4.1.318.1.1.1.3.2.3 | ScalarupsAdvInputMinLineVoltage | read-only | mandatory | The minimum utility line voltage in VAC over the previous 1 minute period. |
| 1.3.6.1.4.1.318.1.1.1.3.2.4 | ScalarupsAdvInputFrequency | read-only | mandatory | The current input frequency to the UPS system in Hz. |
| 1.3.6.1.4.1.318.1.1.1.3.2.5 | ScalarupsAdvInputLineFailCause | read-only | mandatory | The reason for the occurrence of the last transfer to UPS battery power. The variable is set to: - noTransfer(1) - highLineVoltage(2) by an over voltage greate… |
| 1.3.6.1.4.1.318.1.1.1.3.2.6 | ScalarupsAdvInputNominalFrequency | read-only | mandatory | The nominal input frequency of the UPS system in Hz. |
| 1.3.6.1.4.1.318.1.1.1.3.2.7 | ScalarupsAdvInputNominalVoltage | read-only | mandatory | The nominal input voltage of the UPS system in VAC. |
| 1.3.6.1.4.1.318.1.1.1.3.2.8 | ScalarupsAdvInputBypassNominalFrequency | read-only | mandatory | The nominal bypass input frequency of the UPS system in Hz. |
| 1.3.6.1.4.1.318.1.1.1.3.2.9 | ScalarupsAdvInputBypassNominalVoltage | read-only | mandatory | The nominal bypass input voltage of the UPS system in VAC. |
| 1.3.6.1.4.1.318.1.1.1.3.2.10 | TableupsAdvInputStatisticsTable | not-accessible | mandatory | A list of input table entries. The number of entries is given by the value of upsPhaseNumInputs. |
| 1.3.6.1.4.1.318.1.1.1.3.2.10.1 | RowupsAdvInputStatisticsEntry | not-accessible | mandatory | An entry containing information applicable to a particular input. |
| 1.3.6.1.4.1.318.1.1.1.3.2.10.1.1 | ColumnupsAdvInputStatisticsIndex | read-only | mandatory | The input identifier. |
| 1.3.6.1.4.1.318.1.1.1.3.2.10.1.2 | ColumnupsAdvInputApparentPower | read-only | mandatory | The input apparent power(sum of all of the three phases) measured in kVA. |
| 1.3.6.1.4.1.318.1.1.1.3.2.10.1.3 | ColumnupsAdvInputVoltageTHD | read-only | mandatory | The input voltage Total Harmonic Distortion in percent. |
| 1.3.6.1.4.1.318.1.1.1.3.2.10.1.4 | ColumnupsAdvInputBypassVoltageTHD | read-only | mandatory | The bypass input voltage Total Harmonic Distortion in percent. |
| 1.3.6.1.4.1.318.1.1.1.3.2.10.1.5 | ColumnupsAdvInputPeakCurrent | read-only | mandatory | The input peak current in Amperes. |
| 1.3.6.1.4.1.318.1.1.1.3.2.10.1.6 | ColumnupsAdvInputBypassPeakCurrent | read-only | mandatory | The bypass input peak current in Amperes. |
| 1.3.6.1.4.1.318.1.1.1.3.2.10.1.7 | ColumnupsAdvInputActivePower | read-only | mandatory | The input active power measured in kW. |
| 1.3.6.1.4.1.318.1.1.1.3.2.11 | ScalarupsAdvInputTotalApparentPower | read-only | mandatory | The input total apparent power(sum of all three phases) of the UPS system in kVA. |
| 1.3.6.1.4.1.318.1.1.1.3.2.12 | ScalarupsAdvInputTotalActivePower | read-only | mandatory | The input total active power(sum of all three phases) of the UPS system in kW. |
| 1.3.6.1.4.1.318.1.1.1.3.2.13 | ScalarupsAdvInputBypassTotalApparentPower | read-only | mandatory | The input bypass total apparent power(sum of all three phases) of the UPS system in kVA. |
| 1.3.6.1.4.1.318.1.1.1.3.2.14 | ScalarupsAdvInputBypassTotalActivePower | read-only | mandatory | The input bypass total active power(sum of all three phases) of the UPS system in kW. |
| 1.3.6.1.4.1.318.1.1.1.3.2.15 | ScalarupsAdvInputEnergyUsage | read-only | mandatory | The input energy usage of the UPS in kWh. |
| 1.3.6.1.4.1.318.1.1.1.3.3 | NodeupsHighPrecInput | |||
| 1.3.6.1.4.1.318.1.1.1.3.3.1 | ScalarupsHighPrecInputLineVoltage | read-only | mandatory | The current utility line voltage in tenths of VAC. |
| 1.3.6.1.4.1.318.1.1.1.3.3.2 | ScalarupsHighPrecInputMaxLineVoltage | read-only | mandatory | The maximum utility line voltage in tenths of VAC over the previous 1 minute period. |
| 1.3.6.1.4.1.318.1.1.1.3.3.3 | ScalarupsHighPrecInputMinLineVoltage | read-only | mandatory | The minimum utility line voltage in tenths of VAC over the previous 1 minute period. |
| 1.3.6.1.4.1.318.1.1.1.3.3.4 | ScalarupsHighPrecInputFrequency | read-only | mandatory | The current input frequency to the UPS system in tenths of Hz. |
| 1.3.6.1.4.1.318.1.1.1.3.3.5 | ScalarupsHighPrecInputEnergyUsage | read-only | mandatory | The input energy usage of the UPS in hundredths of kWh. |
| 1.3.6.1.4.1.318.1.1.1.3.3.6 | ScalarupsHighPrecInputBypassVoltage | read-only | mandatory | The current bypass line voltage in tenths of VAC. |
| 1.3.6.1.4.1.318.1.1.1.3.3.7 | ScalarupsHighPrecInputBypassFrequency | read-only | mandatory | The current input bypass frequency to the UPS system in tenths of Hz. |
| 1.3.6.1.4.1.318.1.1.1.4 | NodeupsOutput | |||
| 1.3.6.1.4.1.318.1.1.1.4.1 | NodeupsBasicOutput | |||
| 1.3.6.1.4.1.318.1.1.1.4.1.1 | ScalarupsBasicOutputStatus | read-only | mandatory | The current state of the UPS. If the UPS is unable to determine the state of the UPS this variable is set to unknown(1). |
| 1.3.6.1.4.1.318.1.1.1.4.1.2 | ScalarupsBasicOutputPhase | read-only | mandatory | The current output phase. |
| 1.3.6.1.4.1.318.1.1.1.4.1.3 | ScalarupsBasicSystemStatus | read-only | mandatory | Current state for the whole system (UPS and surrounding breakers). If the UPS is unable to determine the state of the system, this variable is set to unknown(1… |
| 1.3.6.1.4.1.318.1.1.1.4.1.4 | ScalarupsBasicSystemInternalTemperature | read-only | mandatory | The actual internal temperature of the UPS system in Celsius. |
| 1.3.6.1.4.1.318.1.1.1.4.1.5 | ScalarupsBasicSystemInverterStatus | read-only | mandatory | The current state of the UPS inverter. If the UPS is unable to determine the state of the inverter, this variable is set to unknown(1). |
| 1.3.6.1.4.1.318.1.1.1.4.1.6 | ScalarupsBasicSystemPFCStatus | read-only | mandatory | The general status of the power factor correction (AC input stage of the UPS). If the UPS is unable to determine the state of PFC, this variable is set to unkn… |
| 1.3.6.1.4.1.318.1.1.1.4.1.7 | ScalarupsBasicOutputACwiringConfiguration | read-only | mandatory | Indicates if neutral wire on output side of the UPS is used (load wired line to neutral). If the UPS is unable to determine the state of neutral, this variable… |
| 1.3.6.1.4.1.318.1.1.1.4.2 | NodeupsAdvOutput | |||
| 1.3.6.1.4.1.318.1.1.1.4.2.1 | ScalarupsAdvOutputVoltage | read-only | mandatory | The output voltage of the UPS system in VAC. |
| 1.3.6.1.4.1.318.1.1.1.4.2.2 | ScalarupsAdvOutputFrequency | read-only | mandatory | The current output frequency of the UPS system in Hz. |
| 1.3.6.1.4.1.318.1.1.1.4.2.3 | ScalarupsAdvOutputLoad | read-only | mandatory | The current UPS load expressed in percent of rated capacity. |
| 1.3.6.1.4.1.318.1.1.1.4.2.4 | ScalarupsAdvOutputCurrent | read-only | mandatory | The current in amperes drawn by the load on the UPS. |
| 1.3.6.1.4.1.318.1.1.1.4.2.5 | ScalarupsAdvOutputRedundancy | read-only | mandatory | The number of power modules which can fail or be removed without causing the UPS to generate a Minimum Redundancy Lost event. |
| 1.3.6.1.4.1.318.1.1.1.4.2.6 | ScalarupsAdvOutputKVACapacity | read-only | mandatory | The maximum load that this UPS can support. |
| 1.3.6.1.4.1.318.1.1.1.4.2.7 | ScalarupsAdvOutputNominalFrequency | read-only | mandatory | The nominal output frequency of the UPS system in Hz. |
| 1.3.6.1.4.1.318.1.1.1.4.2.8 | ScalarupsAdvOutputActivePower | read-only | mandatory | The total output active power of the UPS system in W. The total active power is the sum of phase 1, phase 2 and phase 3 power. |
| 1.3.6.1.4.1.318.1.1.1.4.2.9 | ScalarupsAdvOutputApparentPower | read-only | mandatory | The total output apparent power of all phases of the UPS system in VA. |
| 1.3.6.1.4.1.318.1.1.1.4.2.10 | TableupsAdvOutputStatisticsTable | not-accessible | mandatory | A list of input table entries. The number of entries is given by the value of upsPhaseNumOutputs. |
| 1.3.6.1.4.1.318.1.1.1.4.2.10.1 | RowupsAdvOutputStatisticsEntry | not-accessible | mandatory | An entry containing information applicable to a particular output. |
| 1.3.6.1.4.1.318.1.1.1.4.2.10.1.1 | ColumnupsAdvOutputStatisticsIndex | read-only | mandatory | The output identifier. |
| 1.3.6.1.4.1.318.1.1.1.4.2.10.1.2 | ColumnupsAdvOutputPeakCurrent | read-only | mandatory | The output peak current in Amperes. |
| 1.3.6.1.4.1.318.1.1.1.4.2.10.1.3 | ColumnupsAdvOutputCurrentTHD | read-only | mandatory | The output current Total Harmonic Distortion in percent. |
| 1.3.6.1.4.1.318.1.1.1.4.2.10.1.4 | ColumnupsAdvOutputCrestFactor | read-only | mandatory | The output current crest factor expressed in tenths. |
| 1.3.6.1.4.1.318.1.1.1.4.2.11 | ScalarupsAdvOutputNeutralCurrent | read-only | mandatory | The neutral current in amperes. |
| 1.3.6.1.4.1.318.1.1.1.4.2.12 | ScalarupsAdvOutputEnergyUsage | read-only | mandatory | The output energy usage of the UPS in kWh. |
| 1.3.6.1.4.1.318.1.1.1.4.2.13 | ScalarupsAdvOutputSourceSynchronization | read-only | mandatory | Indicates the synchronization source for the inverter output frequency. 1. Main 2. Internal 3. External 4. On AC Bypass. 5. External / On Bypass For other valu… |
| 1.3.6.1.4.1.318.1.1.1.4.2.14 | ScalarupsAdvOutputInverterFrequency | read-only | mandatory | Output frequency in Hz measured at the output of inverter. |
| 1.3.6.1.4.1.318.1.1.1.4.3 | NodeupsHighPrecOutput | |||
| 1.3.6.1.4.1.318.1.1.1.4.3.1 | ScalarupsHighPrecOutputVoltage | read-only | mandatory | The output voltage of the UPS system in tenths of VAC. |
| 1.3.6.1.4.1.318.1.1.1.4.3.2 | ScalarupsHighPrecOutputFrequency | read-only | mandatory | The current output frequency of the UPS system in tenths of Hz. |
| 1.3.6.1.4.1.318.1.1.1.4.3.3 | ScalarupsHighPrecOutputLoad | read-only | mandatory | The current UPS load expressed in tenths of percent of rated capacity. |
| 1.3.6.1.4.1.318.1.1.1.4.3.4 | ScalarupsHighPrecOutputCurrent | read-only | mandatory | The current in tenths of amperes drawn by the load on the UPS. |
| 1.3.6.1.4.1.318.1.1.1.4.3.5 | ScalarupsHighPrecOutputEfficiency | read-only | mandatory | The positive values represent efficiency of the UPS in tenths of percent. -1 If UPS supports this OID but the result is not available -2 Load is too low to rep… |
| 1.3.6.1.4.1.318.1.1.1.4.3.6 | ScalarupsHighPrecOutputEnergyUsage | read-only | mandatory | The output energy usage of the UPS in hundredths of kWh. |
| 1.3.6.1.4.1.318.1.1.1.5 | NodeupsConfig | |||
| 1.3.6.1.4.1.318.1.1.1.5.1 | NodeupsBasicConfig | |||
| 1.3.6.1.4.1.318.1.1.1.5.1.1 | ScalarupsBasicConfigNumDevices | read-only | mandatory | The number of devices that are plugged into the UPS. This value is customer configurable from the device entry table |
| 1.3.6.1.4.1.318.1.1.1.5.1.2 | TableupsBasicConfigDeviceTable | not-accessible | mandatory | A list of devices that are plugged into the UPS. The number of entries is given by the value of upsBasicConfigNumDevices. |
| 1.3.6.1.4.1.318.1.1.1.5.1.2.1 | RowupsBasicConfigDeviceEntry | not-accessible | mandatory | The devices plugged in to the UPS. |
| 1.3.6.1.4.1.318.1.1.1.5.1.2.1.1 | ColumndeviceIndex | read-only | mandatory | The index of the device that is plugged into the UPS. |
| 1.3.6.1.4.1.318.1.1.1.5.1.2.1.2 | ColumndeviceName | read-write | mandatory | The name/description of the device plugged into the UPS. |
| 1.3.6.1.4.1.318.1.1.1.5.1.2.1.3 | ColumnvaRating | read-write | mandatory | The volt-amp rating of the device plugged into the UPS. |
| 1.3.6.1.4.1.318.1.1.1.5.1.2.1.4 | ColumnacceptThisDevice | read-write | mandatory | An entry is added if yes, the entry is deleted if no. |
| 1.3.6.1.4.1.318.1.1.1.5.2 | NodeupsAdvConfig | |||
| 1.3.6.1.4.1.318.1.1.1.5.2.1 | ScalarupsAdvConfigRatedOutputVoltage | read-write | mandatory | The nominal output voltage from the UPS in VAC. For a list of allowed values supported by your UPS model, see the UPS User's Manual. If a value other than a su… |
| 1.3.6.1.4.1.318.1.1.1.5.2.2 | ScalarupsAdvConfigHighTransferVolt | read-write | mandatory | The maximum line voltage in VAC allowed before the UPS system transfers to battery backup. For a list of allowed values supported by your UPS model, see the UP… |
| 1.3.6.1.4.1.318.1.1.1.5.2.3 | ScalarupsAdvConfigLowTransferVolt | read-write | mandatory | The minimum line voltage in VAC allowed before the UPS system transfers to battery backup. For a list of allowed values supported by your UPS model, see the UP… |
| 1.3.6.1.4.1.318.1.1.1.5.2.4 | ScalarupsAdvConfigAlarm | read-write | mandatory | A flag indicating how the UPS should handle audible line fail alarms: timed(1): UPS alarm will sound after a preset timed duration starting from the line fail … |
| 1.3.6.1.4.1.318.1.1.1.5.2.5 | ScalarupsAdvConfigAlarmTimer | read-write | mandatory | The time after initial line failure at which the UPS begins emitting audible alarms (beeping). This timer is observed only if the value of extControlAlarm is t… |
| 1.3.6.1.4.1.318.1.1.1.5.2.6 | ScalarupsAdvConfigMinReturnCapacity | read-write | mandatory | The minimum battery capacity required before the UPS will return from a low battery shutdown condition. The capacity is measured from 0% battery capacity (or L… |
| 1.3.6.1.4.1.318.1.1.1.5.2.7 | ScalarupsAdvConfigSensitivity | read-write | mandatory | The sensitivity of the UPS to utility line abnormalities or noises. |
| 1.3.6.1.4.1.318.1.1.1.5.2.8 | ScalarupsAdvConfigLowBatteryRunTime | read-write | mandatory | The desired run time of the UPS, in seconds, once the low battery condition is reached. During this time the UPS will produce a constant warning tone which can… |
| 1.3.6.1.4.1.318.1.1.1.5.2.9 | ScalarupsAdvConfigReturnDelay | read-write | mandatory | The delay in seconds after utility line power returns before the UPS will turn on. This value is also used when the UPS comes out of a reboot and before the UP… |
| 1.3.6.1.4.1.318.1.1.1.5.2.10 | ScalarupsAdvConfigShutoffDelay | read-write | mandatory | The delay in seconds the UPS remains on after being told to turn off. For a list of allowed values supported by your UPS model, see the UPS User's Manual. If a… |
| 1.3.6.1.4.1.318.1.1.1.5.2.11 | ScalarupsAdvConfigUpsSleepTime | read-write | mandatory | The time in seconds for the UPS to go to 'sleep' when instructed. When in sleep mode, the UPS will not provide output power regardless of the input line state.… |
| 1.3.6.1.4.1.318.1.1.1.5.2.12 | ScalarupsAdvConfigSetEEPROMDefaults | read-write | mandatory | WRITE: Resets the UPS EEPROM variables to default values. READ: returns 1 |
| 1.3.6.1.4.1.318.1.1.1.5.2.13 | TableupsAdvConfigDipSwitchTable | not-accessible | mandatory | Current settings of UPS dip switches. |
| 1.3.6.1.4.1.318.1.1.1.5.2.13.1 | RowupsAdvConfigDipSwitchEntry | not-accessible | mandatory | The current setting of one dip switch. |
| 1.3.6.1.4.1.318.1.1.1.5.2.13.1.1 | ColumndipSwitchIndex | read-only | mandatory | The index of a UPS dip switch. |
| 1.3.6.1.4.1.318.1.1.1.5.2.13.1.2 | ColumndipSwitchStatus | read-only | mandatory | The setting of a UPS dip switch. |
| 1.3.6.1.4.1.318.1.1.1.5.2.14 | ScalarupsAdvConfigBattExhaustThresh | read-write | mandatory | The number of seconds prior to battery exhaustion when the UPS will switch off power to its load. |
| 1.3.6.1.4.1.318.1.1.1.5.2.15 | ScalarupsAdvConfigPassword | read-write | mandatory | The password entered at the UPS front panel to enable local configuration of the EEProm. If the password is disabled or is not supported, then the agent return… |
| 1.3.6.1.4.1.318.1.1.1.5.2.16 | TableupsAdvConfigAllowedSetTable | not-accessible | mandatory | The table listing the allowed values for all discrete configurable UPS variables. |
| 1.3.6.1.4.1.318.1.1.1.5.2.16.1 | RowupsAdvConfigAllowedSetEntry | not-accessible | mandatory | The table entry for a configurable UPS variable. |
| 1.3.6.1.4.1.318.1.1.1.5.2.16.1.1 | ColumnapcUpsConfigFieldIndex | read-only | mandatory | The index to an eeprom field entry. |
| 1.3.6.1.4.1.318.1.1.1.5.2.16.1.2 | ColumnapcUpsConfigFieldOID | read-only | mandatory | The OID of the current configurable value. |
| 1.3.6.1.4.1.318.1.1.1.5.2.16.1.3 | ColumnapcUpsConfigFieldValueRange | read-only | mandatory | The discrete set of allowed values of a configurable register. Individual values are delimited by a comma. |
| 1.3.6.1.4.1.318.1.1.1.5.2.17 | ScalarupsAdvConfigBattCabAmpHour | read-write | mandatory | Configure the amp-hour setting of the UPS battery cabinet. |
| 1.3.6.1.4.1.318.1.1.1.5.2.18 | ScalarupsAdvConfigPositionSelector | read-write | mandatory | Configure UPS position selector. If the UPS doesn't support this configuration it will report unknown (1). The positions are either rack (2) for rack mounted o… |
| 1.3.6.1.4.1.318.1.1.1.5.2.19 | ScalarupsAdvConfigOutputFreqRange | read-write | mandatory | Configure the output frequency tolerance range. unknown(1) indicates the output frequency is unknown. freqRangeAUTO(2) configure the output frequency range for… |
| 1.3.6.1.4.1.318.1.1.1.5.2.20 | ScalarupsAdvConfigUPSFail | read-write | mandatory | Configure the UPS fail action. If UPS fails, and frequency or voltage is out of range it will either GotoBypass (2) or DropLoad (3). This OID will report unkno… |
| 1.3.6.1.4.1.318.1.1.1.5.2.21 | ScalarupsAdvConfigAlarmRedundancy | read-write | mandatory | Configure settings of UPS alarm if the redundancy is under the current redundancy. Use 0 for never. |
| 1.3.6.1.4.1.318.1.1.1.5.2.22 | ScalarupsAdvConfigAlarmLoadOver | read-write | mandatory | Configure settings of UPS alarm if the load is over the current load in kVA. Use -1 for never. |
| 1.3.6.1.4.1.318.1.1.1.5.2.23 | ScalarupsAdvConfigAlarmRuntimeUnder | read-write | mandatory | Configure settings of UPS alarm if the runtime is under the current time of minutes. Use -1 for never. |
| 1.3.6.1.4.1.318.1.1.1.5.2.24 | ScalarupsAdvConfigVoutReporting | read-write | mandatory | Configure the way the UPS scales its output voltage readings. unknown(1) indicates the Vout Reporting is unknown. voutAUTO(2) configure the Vout Reporting for … |
| 1.3.6.1.4.1.318.1.1.1.5.2.25 | ScalarupsAdvConfigNumExternalBatteries | read-write | mandatory | Configure the number of external batteries connected to the UPS. |
| 1.3.6.1.4.1.318.1.1.1.5.2.26 | ScalarupsAdvConfigSimpleSignalShutdowns | read-write | mandatory | Configure Simple Signal shutdown commands from the Simple Signal port to be issued to the UPS. unknown(1) indicates the Simple Signal Shutdown setting is unkno… |
| 1.3.6.1.4.1.318.1.1.1.5.2.27 | ScalarupsAdvConfigMaxShutdownTime | read-write | mandatory | The maximum amount of time for server shutdown to complete before a UPS shutdown occurs. |
| 1.3.6.1.4.1.318.1.1.1.5.2.28 | ScalarupsAsiUpsControlServerRequestShutdown | read-write | mandatory | Start a server shutdown sequence: serverShutdownOff: Shutdown server and turn off UPS serverShutdownReboot: Shutdown server and turn reboot UPS. |
| 1.3.6.1.4.1.318.1.1.1.5.2.29 | ScalarupsAdvConfigMinReturnRuntime | read-write | mandatory | The minimum amount of run time in seconds required before the output will be turned on, using power calculation captured at start of last shutdown. |
| 1.3.6.1.4.1.318.1.1.1.5.2.30 | ScalarupsAdvConfigBasicSignalLowBatteryDuration | read-write | mandatory | The duration of runtime in seconds during an on-battery condition at which the UPS will signal the basic low battery shutdown condition. |
| 1.3.6.1.4.1.318.1.1.1.5.2.31 | ScalarupsAdvConfigBypassPhaseLockRequired | read-write | mandatory | Sets the condition for when bypass is an acceptable mode of operation as a requirement. |
| 1.3.6.1.4.1.318.1.1.1.5.2.32 | ScalarupsAdvConfigOutputFreqSlewRate | read-write | mandatory | The rate at which the UPS will change its output frequency in response to utility frequency changes. |
| 1.3.6.1.4.1.318.1.1.1.5.2.33 | ScalarupsAdvConfigChargerLevel | read-write | mandatory | Sets the rate at which the UPS charges its batteries. |
| 1.3.6.1.4.1.318.1.1.1.5.2.34 | ScalarupsAdvConfigBypassToleranceSetting | read-write | mandatory | This setting allows selecting from standard bypass tolerance configurations to suit their situation. |
| 1.3.6.1.4.1.318.1.1.1.5.2.35 | ScalarupsAdvConfigMainsSetting | read-only | mandatory | Configure the type of mains supply system. singleInput (1) indicates a single supply system. dualInput (2) indicates a dual supply system. |
| 1.3.6.1.4.1.318.1.1.1.5.2.36 | ScalarupsAdvConfigACWiringSetting | read-only | mandatory | Configure the AC wiring of the system. threeWire (1) indicates 3-wire system configuration. fourWire (2) indicates 4-wire system configuration. |
| 1.3.6.1.4.1.318.1.1.1.5.2.37 | ScalarupsAdvConfigUpperOutputVoltTolerance | read-write | mandatory | Upper tolerance of the output RMS voltage before transferring to bypass. Expressed as percent of nominal voltage. |
| 1.3.6.1.4.1.318.1.1.1.5.2.38 | ScalarupsAdvConfigLowerOutputVoltTolerance | read-write | mandatory | Lower tolerance of the output RMS voltage before transferring to bypass. Expressed as percent of nominal voltage. |
| 1.3.6.1.4.1.318.1.1.1.5.2.39 | ScalarupsAdvConfigUpperBypassVoltTolerance | read-write | mandatory | Upper tolerance of the bypass voltage that allows transfer to bypass by user. Expressed as percent of nominal voltage. |
| 1.3.6.1.4.1.318.1.1.1.5.2.40 | ScalarupsAdvConfigLowerBypassVoltTolerance | read-write | mandatory | Lower tolerance of the bypass voltage that allows transfer to bypass by user. Expressed as percent of nominal voltage. |
| 1.3.6.1.4.1.318.1.1.1.5.2.41 | ScalarupsAdvConfigOutofSyncBypassTransferDelay | read-write | mandatory | Configure the time (in milliseconds), indicating the gap in output voltage if an asynchronous transfer to bypass needs to occur. |
| 1.3.6.1.4.1.318.1.1.1.5.2.43 | ScalarupsAdvConfigWarningAlarmDelay | read-write | mandatory | Configure the time delay for reporting warning alarms (in seconds). |
| 1.3.6.1.4.1.318.1.1.1.5.2.44 | ScalarupsAdvConfigInformationalAlarmDelay | read-write | mandatory | Configure the time delay for reporting informational alarms (in seconds). |
| 1.3.6.1.4.1.318.1.1.1.5.2.45 | ScalarupsAdvConfigGreenMode | read-write | mandatory | Enable/Disable UPS green mode feature. |
| 1.3.6.1.4.1.318.1.1.1.5.2.46 | ScalarupsAdvConfigLCDLocalLanguage | read-write | mandatory | Configure the language setting of the UPS LCD display information. |
| 1.3.6.1.4.1.318.1.1.1.5.2.47 | ScalarupsAdvConfigLCDLockOut | read-write | mandatory | Enable/Disable the control function of the UPS via the LCD Display. |
| 1.3.6.1.4.1.318.1.1.1.5.2.48 | ScalarupsAdvConfigChargerRate | read-write | mandatory | Change the maximum allowed UPS charge rate on select products where 100% represents the manufacturer's recommended rate. A charge/discharge rate of C/10 for a … |
| 1.3.6.1.4.1.318.1.1.1.5.2.49 | ScalarupsAdvConfigBatterySelection | read-write | mandatory | Configure the installed battery type on select products where VRLA is Valve Regulated Lead Acid type battery, Vented Cell is a wet cell type (car) battery, NiC… |
| 1.3.6.1.4.1.318.1.1.1.5.2.50 | ScalarupsAdvConfigBatteryHealthAlarmWarningTime | read-write | mandatory | Configure the number of days before the battery health is depleted that the battery health alarm is activated. Setting this to -1, if supported by the UPS, wil… |
| 1.3.6.1.4.1.318.1.1.1.5.2.51 | ScalarupsAdvConfigBatteryHealthAlarmSleepTime | read-write | mandatory | Configure the number of days that the UPS's battery health alarm should sleep before being activated again after being acknowledged. Setting this to -1, if sup… |
| 1.3.6.1.4.1.318.1.1.1.5.2.52 | ScalarupsAdvConfigSignalFlashVoltage | read-write | mandatory | Configure the signal flash voltage in tenths of volts. |
| 1.3.6.1.4.1.318.1.1.1.5.2.53 | ScalarupsAdvConfigBatteryTemperatureCompensation | read-write | mandatory | Configure the battery temperature compensation voltage in hundreds of volts per degree C. On products which support this field, the charger voltage is reduced … |
| 1.3.6.1.4.1.318.1.1.1.5.2.54 | ScalarupsAdvConfigBatteryChargerType | read-write | mandatory | This OID describes type of battery charger used: standard or extended. 1 - Internal charger, 2 - Extended (CLA), 3 - Large extension (other cases), 4 - Extra l… |
| 1.3.6.1.4.1.318.1.1.1.5.2.55 | ScalarupsAdvConfigAutomaticRestart | read-write | mandatory | Indicates whether Automatic Restart is enabled or disabled. |
| 1.3.6.1.4.1.318.1.1.1.5.2.56 | ScalarupsAdvConfigDeepDischargeProtection | read-write | mandatory | Indicates whether protection against deep discharge is enabled or disabled. |
| 1.3.6.1.4.1.318.1.1.1.5.2.57 | ScalarupsAdvConfigFreqBypassTransferRange | read-write | mandatory | Tolerance of bypass AC frequency to switch on bypass. The frequency must be in range of -X% to +X% around the nominal value. |
| 1.3.6.1.4.1.318.1.1.1.5.2.58 | ScalarupsAdvConfigUpsPowerconverterType | read-write | mandatory | This value indicates the type of UPS in terms of output phase and redundancy. 2 - Galaxy 7000 Unitary 3:3 3 - Galaxy 7000 Redundant 3:3 4 - Galaxy 7000 Paralle… |
| 1.3.6.1.4.1.318.1.1.1.5.2.59 | ScalarupsAdvConfigFrequencyConverterMode | read-write | mandatory | Indicates whether the output frequency is in Auto Ranging or Frequency converter mode. In Auto Ranging mode the inverter provides output frequency in the same … |
| 1.3.6.1.4.1.318.1.1.1.5.2.60 | ScalarupsAdvConfigACQualificationTime | read-write | mandatory | The time in seconds that the voltage is required to be in the acceptable range before being declared to be acceptable. |
| 1.3.6.1.4.1.318.1.1.1.6 | NodeupsControl | |||
| 1.3.6.1.4.1.318.1.1.1.6.1 | NodeupsBasicControl | |||
| 1.3.6.1.4.1.318.1.1.1.6.1.1 | ScalarupsBasicControlConserveBattery | read-write | mandatory | Setting this variable to turnUpsOffToConserveBattery(2) causes a UPS on battery to be put into 'sleep' mode. The UPS will turn back on when utility power is re… |
| 1.3.6.1.4.1.318.1.1.1.6.2 | NodeupsAdvControl | |||
| 1.3.6.1.4.1.318.1.1.1.6.2.1 | ScalarupsAdvControlUpsOff | read-write | mandatory | Setting this variable to turnUpsOff(2) causes the UPS to shut off. When in this state, the UPS will not provide output power regardless of the input line state… |
| 1.3.6.1.4.1.318.1.1.1.6.2.2 | ScalarupsAdvControlRebootShutdownUps | read-write | mandatory | Setting this variable to rebootShutdownUps(2) causes the UPS to shut off and turn back on (as long as good AC input power is available, otherwise the UPS will … |
| 1.3.6.1.4.1.318.1.1.1.6.2.3 | ScalarupsAdvControlUpsSleep | read-write | mandatory | Setting this variable to putUpsToSleep(2) causes the UPS to go to sleep for the time specified by upsAdvConfigUpsSleepTime. Setting this variable to putUpsToSl… |
| 1.3.6.1.4.1.318.1.1.1.6.2.4 | ScalarupsAdvControlSimulatePowerFail | read-write | mandatory | Setting this variable to simulatePowerFailure(2) causes the UPS switch to battery power. Setting this value to noSimulatePowerFailure(1) has no effect. The val… |
| 1.3.6.1.4.1.318.1.1.1.6.2.5 | ScalarupsAdvControlFlashAndBeep | read-write | mandatory | Setting this variable to flashAndBeep(2) causes the UPS to beep and simultaneously turn on the UPS front panel lights (Smart-UPS only). If this UPS is an activ… |
| 1.3.6.1.4.1.318.1.1.1.6.2.6 | ScalarupsAdvControlTurnOnUPS | read-write | mandatory | Setting this variable to turnOnUPS(2) causes the UPS to be turned on immediately. If this UPS is an active member of a Synchronized Control Group (SCG), the tu… |
| 1.3.6.1.4.1.318.1.1.1.6.2.7 | ScalarupsAdvControlBypassSwitch | read-write | mandatory | This switch puts the UPS in or out of bypass mode. |
| 1.3.6.1.4.1.318.1.1.1.6.2.8 | ScalarupsAdvControlRebootUpsWithOrWithoutAC | read-write | mandatory | Setting this variable to rebootUpsImmediatelyWithOrWithoutAC (2) causes the UPS to turn off immediately, wait for a minimum time (typically 8 seconds), and the… |
| 1.3.6.1.4.1.318.1.1.1.6.2.9 | ScalarupsAdvControlFirmwareUpdate | read-write | mandatory | Setting this variable to firmwareUpdate(2) causes the UPS to begin a firmware update if possible. Setting this value to noFirmwareUpdate(1) will clear the prev… |
| 1.3.6.1.4.1.318.1.1.1.7 | NodeupsTest | |||
| 1.3.6.1.4.1.318.1.1.1.7.1 | NodeupsBasicTest | |||
| 1.3.6.1.4.1.318.1.1.1.7.2 | NodeupsAdvTest | |||
| 1.3.6.1.4.1.318.1.1.1.7.2.1 | ScalarupsAdvTestDiagnosticSchedule | read-write | mandatory | The UPS system's automatic battery test schedule. |
| 1.3.6.1.4.1.318.1.1.1.7.2.2 | ScalarupsAdvTestDiagnostics | read-write | mandatory | Setting this variable to testDiagnostics(2) causes the UPS to perform a diagnostic self test. Setting this value to noTestDiagnostics(1) has no effect. The val… |
| 1.3.6.1.4.1.318.1.1.1.7.2.3 | ScalarupsAdvTestDiagnosticsResults | read-only | mandatory | The results of the last UPS diagnostics test performed. |
| 1.3.6.1.4.1.318.1.1.1.7.2.4 | ScalarupsAdvTestLastDiagnosticsDate | read-only | mandatory | The date the last UPS diagnostics test was performed in mm/dd/yy format. |
| 1.3.6.1.4.1.318.1.1.1.7.2.5 | ScalarupsAdvTestRuntimeCalibration | read-write | mandatory | Setting this variable to performCalibration(2) causes the UPS to discharge to calibrate the UPS. The test will only start if the battery capacity is 100%. The … |
| 1.3.6.1.4.1.318.1.1.1.7.2.6 | ScalarupsAdvTestCalibrationResults | read-only | mandatory | The results of the last runtime calibration. Value ok(1) means a successful runtime calibration. Value invalidCalibration(2) indicates last calibration did not… |
| 1.3.6.1.4.1.318.1.1.1.7.2.7 | ScalarupsAdvTestCalibrationDate | read-only | mandatory | The date the last UPS runtime calibration was performed in mm/dd/yy format. |
| 1.3.6.1.4.1.318.1.1.1.7.2.8 | ScalarupsAdvTestDiagnosticTime | read-write | mandatory | The time of the day to perform automatic battery test. Expressed in 24 hour notation - hh:mm. |
| 1.3.6.1.4.1.318.1.1.1.7.2.9 | ScalarupsAdvTestDiagnosticDay | read-write | mandatory | The day of the week to perform automatic battery test. |
| 1.3.6.1.4.1.318.1.1.1.7.2.10 | ScalarupsAdvTestBatteryInterval | read-write | mandatory | The UPS system's automatic battery test period. |
| 1.3.6.1.4.1.318.1.1.1.8 | NodeupsComm | |||
| 1.3.6.1.4.1.318.1.1.1.8.1 | ScalarupsCommStatus | read-only | mandatory | The status of agent's communication with UPS. |
| 1.3.6.1.4.1.318.1.1.1.9 | NodeupsPhase | |||
| 1.3.6.1.4.1.318.1.1.1.9.1 | NodeupsPhaseResetValues | |||
| 1.3.6.1.4.1.318.1.1.1.9.1.1 | ScalarupsPhaseResetMaxMinValues | read-write | mandatory | Reset the maximum and minimum UPS values: upsPhaseInputMaxVoltage, upsPhaseInputMinVoltage, upsPhaseInputMaxCurrent, upsPhaseInputMinCurrent, upsPhaseInputMaxP… |
| 1.3.6.1.4.1.318.1.1.1.9.2 | NodeupsPhaseInput | |||
| 1.3.6.1.4.1.318.1.1.1.9.2.1 | ScalarupsPhaseNumInputs | read-only | mandatory | The number of input feeds to this device. This variable indicates the number of rows in the input table. |
| 1.3.6.1.4.1.318.1.1.1.9.2.2 | TableupsPhaseInputTable | not-accessible | mandatory | A list of input table entries. The number of entries is given by the value of upsPhaseNumInputs. |
| 1.3.6.1.4.1.318.1.1.1.9.2.2.1 | RowupsPhaseInputEntry | not-accessible | mandatory | An entry containing information applicable to a particular input. |
| 1.3.6.1.4.1.318.1.1.1.9.2.2.1.1 | ColumnupsPhaseInputTableIndex | read-only | mandatory | The input identifier. |
| 1.3.6.1.4.1.318.1.1.1.9.2.2.1.2 | ColumnupsPhaseNumInputPhases | read-only | mandatory | The number of input phases utilized in this device. The sum of all the upsPhaseNumInputPhases variable indicates the number of rows in the input phase table. |
| 1.3.6.1.4.1.318.1.1.1.9.2.2.1.3 | ColumnupsPhaseInputVoltageOrientation | read-only | mandatory | The input voltage orientation: 1: unknown for this UPS 2: singlePhase - phase 1 voltage is between Phase 1 and Neutral. 3: splitPhase - phase 1 voltage is betw… |
| 1.3.6.1.4.1.318.1.1.1.9.2.2.1.4 | ColumnupsPhaseInputFrequency | read-only | mandatory | The input frequency in 0.1 Hertz, or -1 if it's unsupported by this UPS. |
| 1.3.6.1.4.1.318.1.1.1.9.2.2.1.5 | ColumnupsPhaseInputType | read-only | mandatory | The input type. |
| 1.3.6.1.4.1.318.1.1.1.9.2.2.1.6 | ColumnupsPhaseInputName | read-write | mandatory | A name given to a particular input. |
| 1.3.6.1.4.1.318.1.1.1.9.2.3 | TableupsPhaseInputPhaseTable | not-accessible | mandatory | A list of input table entries. The number of entries is given by the sum of the upsPhaseNumInputPhases. |
| 1.3.6.1.4.1.318.1.1.1.9.2.3.1 | RowupsPhaseInputPhaseEntry | not-accessible | mandatory | An entry containing information applicable to a particular input phase. |
| 1.3.6.1.4.1.318.1.1.1.9.2.3.1.1 | ColumnupsPhaseInputPhaseTableIndex | read-only | mandatory | The input identifier. |
| 1.3.6.1.4.1.318.1.1.1.9.2.3.1.2 | ColumnupsPhaseInputPhaseIndex | read-only | mandatory | The input phase identifier. |
| 1.3.6.1.4.1.318.1.1.1.9.2.3.1.3 | ColumnupsPhaseInputVoltage | read-only | mandatory | The input voltage in VAC, or -1 if it's unsupported by this UPS. |
| 1.3.6.1.4.1.318.1.1.1.9.2.3.1.4 | ColumnupsPhaseInputMaxVoltage | read-only | mandatory | The maximum input voltage in VAC measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. |
| 1.3.6.1.4.1.318.1.1.1.9.2.3.1.5 | ColumnupsPhaseInputMinVoltage | read-only | mandatory | The minimum input voltage in VAC measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. |
| 1.3.6.1.4.1.318.1.1.1.9.2.3.1.6 | ColumnupsPhaseInputCurrent | read-only | mandatory | The input current in 0.1 amperes, or -1 if it's unsupported by this UPS. |
| 1.3.6.1.4.1.318.1.1.1.9.2.3.1.7 | ColumnupsPhaseInputMaxCurrent | read-only | mandatory | The maximum input current in 0.1 amperes measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 sec… |
| 1.3.6.1.4.1.318.1.1.1.9.2.3.1.8 | ColumnupsPhaseInputMinCurrent | read-only | mandatory | The minimum input current in 0.1 amperes measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 sec… |
| 1.3.6.1.4.1.318.1.1.1.9.2.3.1.9 | ColumnupsPhaseInputPower | read-only | mandatory | The input power in Watts, or -1 if it's unsupported by this UPS. |
| 1.3.6.1.4.1.318.1.1.1.9.2.3.1.10 | ColumnupsPhaseInputMaxPower | read-only | mandatory | The maximum input power in Watts measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. |
| 1.3.6.1.4.1.318.1.1.1.9.2.3.1.11 | ColumnupsPhaseInputMinPower | read-only | mandatory | The minimum input power in Watts measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. |
| 1.3.6.1.4.1.318.1.1.1.9.2.3.1.12 | ColumnupsPhaseInputApparentPower | read-only | mandatory | The input apparent power of the UPS in kVA. |
| 1.3.6.1.4.1.318.1.1.1.9.2.3.1.13 | ColumnupsPhaseInputPowerFactor | read-only | mandatory | The input power factor measured in hundredth. |
| 1.3.6.1.4.1.318.1.1.1.9.3 | NodeupsPhaseOutput | |||
| 1.3.6.1.4.1.318.1.1.1.9.3.1 | ScalarupsPhaseNumOutputs | read-only | mandatory | The number of output feeds to this device. This variable indicates the number of rows in the output table. |
| 1.3.6.1.4.1.318.1.1.1.9.3.2 | TableupsPhaseOutputTable | not-accessible | mandatory | A list of output table entries. The number of entries is given by the value of upsOutputNumPhases. |
| 1.3.6.1.4.1.318.1.1.1.9.3.2.1 | RowupsPhaseOutputEntry | not-accessible | mandatory | An entry containing information applicable to a particular output. |
| 1.3.6.1.4.1.318.1.1.1.9.3.2.1.1 | ColumnupsPhaseOutputTableIndex | read-only | mandatory | The output identifier. |
| 1.3.6.1.4.1.318.1.1.1.9.3.2.1.2 | ColumnupsPhaseNumOutputPhases | read-only | mandatory | The number of output phases utilized in this device. The sum of all the upsPhaseNumOutputPhases variable indicates the number of rows in the output phase table. |
| 1.3.6.1.4.1.318.1.1.1.9.3.2.1.3 | ColumnupsPhaseOutputVoltageOrientation | read-only | mandatory | The output voltage orientation: 1: unknown for this UPS 2: singlePhase - phase 1 voltage is between Phase 1 and Neutral. 3: splitPhase - phase 1 voltage is bet… |
| 1.3.6.1.4.1.318.1.1.1.9.3.2.1.4 | ColumnupsPhaseOutputFrequency | read-only | mandatory | The output frequency in 0.1 Hertz, or -1 if it's unsupported by this UPS. |
| 1.3.6.1.4.1.318.1.1.1.9.3.3 | TableupsPhaseOutputPhaseTable | not-accessible | mandatory | A list of output table entries. The number of entries is given by the sum of the upsPhaseNumOutputPhases. |
| 1.3.6.1.4.1.318.1.1.1.9.3.3.1 | RowupsPhaseOutputPhaseEntry | not-accessible | mandatory | An entry containing information applicable to a particular output phase. |
| 1.3.6.1.4.1.318.1.1.1.9.3.3.1.1 | ColumnupsPhaseOutputPhaseTableIndex | read-only | mandatory | The output identifier. |
| 1.3.6.1.4.1.318.1.1.1.9.3.3.1.2 | ColumnupsPhaseOutputPhaseIndex | read-only | mandatory | The output phase identifier. |
| 1.3.6.1.4.1.318.1.1.1.9.3.3.1.3 | ColumnupsPhaseOutputVoltage | read-only | mandatory | The output voltage in VAC, or -1 if it's unsupported by this UPS. |
| 1.3.6.1.4.1.318.1.1.1.9.3.3.1.4 | ColumnupsPhaseOutputCurrent | read-only | mandatory | The output current in 0.1 amperes drawn by the load on the UPS, or -1 if it's unsupported by this UPS. |
| 1.3.6.1.4.1.318.1.1.1.9.3.3.1.5 | ColumnupsPhaseOutputMaxCurrent | read-only | mandatory | The maximum output current in 0.1 amperes measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 se… |
| 1.3.6.1.4.1.318.1.1.1.9.3.3.1.6 | ColumnupsPhaseOutputMinCurrent | read-only | mandatory | The minimum output current in 0.1 amperes measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 se… |
| 1.3.6.1.4.1.318.1.1.1.9.3.3.1.7 | ColumnupsPhaseOutputLoad | read-only | mandatory | The output load in VA, or -1 if it's unsupported by this UPS. |
| 1.3.6.1.4.1.318.1.1.1.9.3.3.1.8 | ColumnupsPhaseOutputMaxLoad | read-only | mandatory | The maximum output load in VA measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. |
| 1.3.6.1.4.1.318.1.1.1.9.3.3.1.9 | ColumnupsPhaseOutputMinLoad | read-only | mandatory | The minimum output load in VA measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. |
| 1.3.6.1.4.1.318.1.1.1.9.3.3.1.10 | ColumnupsPhaseOutputPercentLoad | read-only | mandatory | The percentage of the UPS load capacity in VA at redundancy @ (n + x) presently being used on this output phase, or -1 if it's unsupported by this UPS. |
| 1.3.6.1.4.1.318.1.1.1.9.3.3.1.11 | ColumnupsPhaseOutputMaxPercentLoad | read-only | mandatory | The maximum percentage of the UPS load capacity in VA measured at redundancy @ (n + x) presently being used on this output phase since the last reset (upsPhase… |
| 1.3.6.1.4.1.318.1.1.1.9.3.3.1.12 | ColumnupsPhaseOutputMinPercentLoad | read-only | mandatory | The minimum percentage of the UPS load capacity in VA measured at redundancy @ (n + x) presently being used on this output phase since the last reset (upsPhase… |
| 1.3.6.1.4.1.318.1.1.1.9.3.3.1.13 | ColumnupsPhaseOutputPower | read-only | mandatory | The output power in Watts, or -1 if it's unsupported by this UPS. |
| 1.3.6.1.4.1.318.1.1.1.9.3.3.1.14 | ColumnupsPhaseOutputMaxPower | read-only | mandatory | The maximum output power in Watts measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. |
| 1.3.6.1.4.1.318.1.1.1.9.3.3.1.15 | ColumnupsPhaseOutputMinPower | read-only | mandatory | The minimum output power in Watts measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. |
| 1.3.6.1.4.1.318.1.1.1.9.3.3.1.16 | ColumnupsPhaseOutputPercentPower | read-only | mandatory | The percentage of the UPS power capacity in Watts at redundancy @ (n + x) presently being used on this output phase, or -1 if it's unsupported by this UPS. |
| 1.3.6.1.4.1.318.1.1.1.9.3.3.1.17 | ColumnupsPhaseOutputMaxPercentPower | read-only | mandatory | The maximum percentage of the UPS power capacity in Watts measured at redundancy @ (n + x) presently being used on this output phase since the last reset (upsP… |
| 1.3.6.1.4.1.318.1.1.1.9.3.3.1.18 | ColumnupsPhaseOutputMinPercentPower | read-only | mandatory | The maximum percentage of the UPS power capacity in Watts measured at redundancy @ (n + x) presently being used on this output phase since the last reset (upsP… |
| 1.3.6.1.4.1.318.1.1.1.9.3.3.1.19 | ColumnupsPhaseOutputPowerFactor | read-only | mandatory | The Output power factor of the UPS in hundredth. |
| 1.3.6.1.4.1.318.1.1.1.9.3.3.1.20 | ColumnupsPhaseOutputApparentPower | read-only | mandatory | Apparent power in kVA |
| 1.3.6.1.4.1.318.1.1.1.9.3.3.1.21 | ColumnupsPhaseOutputInverterVoltage | read-only | mandatory | Output voltage in VAC measured at the output of inverter. |
| 1.3.6.1.4.1.318.1.1.1.10 | NodeupsSyncCtrlGroup | |||
| 1.3.6.1.4.1.318.1.1.1.10.1 | NodeupsSyncCtrlGroupConfig | |||
| 1.3.6.1.4.1.318.1.1.1.10.1.1 | ScalarupsSCGMembershipGroupNumber | read-write | mandatory | The SCG Membership Group number (MGN) is a 16-bit number allowing up to 65534 separate groups that can be identified and distinguished per IP subnet. Zero and … |
| 1.3.6.1.4.1.318.1.1.1.10.1.2 | ScalarupsSCGActiveMembershipStatus | read-write | mandatory | Membership in the configured SCG can be enabled and disabled. If an NMC is configured for an SCG, but has its membership disabled, all synchronized control com… |
| 1.3.6.1.4.1.318.1.1.1.10.1.3 | ScalarupsSCGPowerSynchronizationDelayTime | read-write | mandatory | The Power Synchronization Delay Time (PSD) setting is the maximum number of seconds an SCG Initiator will wait for all SCG members to recover utility power bef… |
| 1.3.6.1.4.1.318.1.1.1.10.1.4 | ScalarupsSCGReturnBatteryCapacityOffset | read-write | mandatory | A reboot command uses the Initiator's Return battery Capacity (RBC) to control when the SCG completes this operation. In a Normal Control Operation (NCC) the U… |
| 1.3.6.1.4.1.318.1.1.1.10.1.5 | ScalarupsSCGMultiCastIP | read-write | mandatory | The MultiCast IP address of the SCG Group. |
| 1.3.6.1.4.1.318.1.1.1.10.2 | NodeupsSyncCtrlGroupStatus | |||
| 1.3.6.1.4.1.318.1.1.1.10.2.1 | ScalarupsSCGNumOfGroupMembers | read-only | mandatory | The number of active, communicating members in the Sync Control Group (SCG). This variable indicates the number of rows in the SCG Status Table. |
| 1.3.6.1.4.1.318.1.1.1.10.2.2 | TableupsSCGStatusTable | not-accessible | mandatory | A list of SCG status table entries. The number of entries is given by the value of upsSCGNumOfGroupMembers. |
| 1.3.6.1.4.1.318.1.1.1.10.2.2.1 | RowupsSCGStatusEntry | not-accessible | mandatory | An entry containing information applicable to a particular SCG Member. |
| 1.3.6.1.4.1.318.1.1.1.10.2.2.1.1 | ColumnupsSCGStatusTableIndex | read-only | mandatory | The index of a status entry for an active, communicating SCG member. |
| 1.3.6.1.4.1.318.1.1.1.10.2.2.1.2 | ColumnupsSCGMemberIP | read-only | mandatory | The IP address of an active, communicating SCG Member. |
| 1.3.6.1.4.1.318.1.1.1.10.2.2.1.3 | ColumnupsSCGACInputStatus | read-only | mandatory | This OID indicates the AC Input Status of the SCG Member. acInGood(1) indicates the AC Input is within tolerance. acInBad(2) indicates the AC Input is not with… |
| 1.3.6.1.4.1.318.1.1.1.10.2.2.1.4 | ColumnupsSCGACOutputStatus | read-only | mandatory | This OID indicates the AC Output Status of the SCG Member. acOutOn(1) indicates the UPS output is providing power to the load. acOutOff(2) indicates the UPS ou… |
| 1.3.6.1.4.1.318.1.1.1.11 | NodeupsState | |||
| 1.3.6.1.4.1.318.1.1.1.11.1 | NodeupsBasicState | |||
| 1.3.6.1.4.1.318.1.1.1.11.1.1 | ScalarupsBasicStateOutputState | read-only | mandatory | An ASCII string containing the 64 flags representing the current state(s) of the UPS. If the Network Card is unable to determine the state of the UPS, this var… |
| 1.3.6.1.4.1.318.1.1.1.11.1.2 | ScalarupsBasicStateAlarmStatus | read-only | mandatory | The alarm status of the Power Module. noAlarms(1) indicates the device has no alarms present. infoAlarm (2) indicates the device has alarms and the highest sev… |
| 1.3.6.1.4.1.318.1.1.1.11.2 | NodeupsAdvState | |||
| 1.3.6.1.4.1.318.1.1.1.11.2.1 | ScalarupsAdvStateAbnormalConditions | read-only | mandatory | An ASCII string containing the 32 flags representing the current active UPS faults. If the Network Card is unable to determine the values of the flags, this va… |
| 1.3.6.1.4.1.318.1.1.1.11.2.2 | ScalarupsAdvStateSymmetra3PhaseSpecificFaults | read-only | mandatory | An ASCII string containing the 64 flags representing the current active UPS specific faults for the Symmetra 3-Phase UPS models. If the Network Card is unable … |
| 1.3.6.1.4.1.318.1.1.1.11.2.3 | ScalarupsAdvStateDP300ESpecificFaults | read-only | mandatory | An ASCII string containing the 64 flags representing the current active UPS specific faults for the Silcon DP300E UPS models. If the Network Card is unable to … |
| 1.3.6.1.4.1.318.1.1.1.11.2.4 | ScalarupsAdvStateSymmetraSpecificFaults | read-only | mandatory | An ASCII string containing the 64 flags representing the current active UPS specific faults for the Symmetra UPS models. If the Network Card is unable to deter… |
| 1.3.6.1.4.1.318.1.1.1.11.2.5 | ScalarupsAdvStateSmartUPSSpecificFaults | read-only | mandatory | An ASCII string containing the 64 flags representing the current active UPS specific faults for the Smart-UPS UPS models. If the Network Card is unable to dete… |
| 1.3.6.1.4.1.318.1.1.1.11.2.6 | ScalarupsAdvStateSystemMessages | read-only | mandatory | An ASCII string containing the 3 digit Decimal code representing the current active message from the System Message Register. Each code should remain active fo… |
| 1.3.6.1.4.1.318.1.1.1.11.2.7 | ScalarupsAdvStateTotaltimeonbattery | read-only | mandatory | Total time the UPS has been in battery operation. |
| 1.3.6.1.4.1.318.1.1.1.11.2.8 | ScalarupsAdvStateTotaltimeonbypass | read-only | mandatory | Total time the UPS has been in bypass operation. |
| 1.3.6.1.4.1.318.1.1.1.11.2.9 | ScalarupsAdvStateTotaltimeonNormal | read-only | mandatory | Total time the UPS has been in normal operation. |
| 1.3.6.1.4.1.318.1.1.1.11.2.10 | ScalarupsAdvStateNumberoftimesonbattery | read-only | mandatory | Number of times the UPS was on battery. Since the last reset of statistical data. |
| 1.3.6.1.4.1.318.1.1.1.11.2.11 | ScalarupsAdvStateNumberoftimesbypass | read-only | mandatory | Number of times the UPS was in bypass. Since the last reset of statistical data. |
| 1.3.6.1.4.1.318.1.1.1.11.2.12 | ScalarupsAdvStateNumberoftimesNormal | read-only | mandatory | Number of times the UPS was in normal operation. Since the last reset of statistical data. |
| 1.3.6.1.4.1.318.1.1.1.11.2.13 | ScalarupsAdvStateEcomode | read-only | mandatory | Eco mode status. 1: UPS is on Eco-mode 2: UPS is not on Eco-mode. |
| 1.3.6.1.4.1.318.1.1.1.11.2.14 | ScalarupsAdvStateLifeCycleManagement | read-only | mandatory | An ASCII string containing the 16 flags representing the life cycle management alerts for the device. If the Network Card is unable to determine the values of … |
| 1.3.6.1.4.1.318.1.1.1.12 | NodeupsOutletGroups | |||
| 1.3.6.1.4.1.318.1.1.1.12.1 | NodeupsOutletGroupStatus | |||
| 1.3.6.1.4.1.318.1.1.1.12.1.1 | ScalarupsOutletGroupStatusTableSize | read-only | mandatory | The number of outlet groups for the UPS. |
| 1.3.6.1.4.1.318.1.1.1.12.1.2 | TableupsOutletGroupStatusTable | not-accessible | mandatory | Allows for getting status of the outlet groups. The number of entries is contained in the upsOutletGroupStatusTableSize OID. |
| 1.3.6.1.4.1.318.1.1.1.12.1.2.1 | RowupsOutletGroupStatusEntry | not-accessible | mandatory | The outlet group status to get. |
| 1.3.6.1.4.1.318.1.1.1.12.1.2.1.1 | ColumnupsOutletGroupStatusIndex | read-only | mandatory | The index to the outlet group entry. |
| 1.3.6.1.4.1.318.1.1.1.12.1.2.1.2 | ColumnupsOutletGroupStatusName | read-only | mandatory | The name of the outlet group. This OID is provided for informational purposes only. This value is set by the upsOutletGroupConfigName OID. |
| 1.3.6.1.4.1.318.1.1.1.12.1.2.1.3 | ColumnupsOutletGroupStatusGroupState | read-only | mandatory | Getting this variable will return the outlet group state. If the outlet group is on, the upsOutletGroupStatusOn (1) value will be returned. If the outlet group… |
| 1.3.6.1.4.1.318.1.1.1.12.1.2.1.4 | ColumnupsOutletGroupStatusCommandPending | read-only | mandatory | Getting this variable will return the command pending state of the outlet group. If a command is pending on the outlet group, the upsOutletGroupCommandPending … |
| 1.3.6.1.4.1.318.1.1.1.12.1.2.1.5 | ColumnupsOutletGroupStatusOutletType | read-only | mandatory | Getting this variable will return the type of outlet group. If present in the system, the main outlet group is 'unswitched' and must be on in order for any of … |
| 1.3.6.1.4.1.318.1.1.1.12.1.2.1.6 | ColumnupsOutletGroupStatusGroupFullState | read-only | mandatory | An ASCII string containing the 32 flags representing the current state(s) of the outlet group. If the Network Card is unable to determine the state of the outl… |
| 1.3.6.1.4.1.318.1.1.1.12.2 | NodeupsOutletGroupConfig | |||
| 1.3.6.1.4.1.318.1.1.1.12.2.1 | ScalarupsOutletGroupConfigTableSize | read-only | mandatory | The number of outlet groups for the UPS. |
| 1.3.6.1.4.1.318.1.1.1.12.2.2 | TableupsOutletGroupConfigTable | not-accessible | mandatory | The list of outlet groups to configure. The number of entries is defined by the upsOutletGroupConfigTableSize OID. |
| 1.3.6.1.4.1.318.1.1.1.12.2.2.1 | RowupsOutletGroupConfigEntry | not-accessible | mandatory | The outlet groups to configure. |
| 1.3.6.1.4.1.318.1.1.1.12.2.2.1.1 | ColumnupsOutletGroupConfigIndex | read-only | mandatory | The index to the outlet group entry. |
| 1.3.6.1.4.1.318.1.1.1.12.2.2.1.2 | ColumnupsOutletGroupConfigName | read-write | mandatory | The name of the outlet group. |
| 1.3.6.1.4.1.318.1.1.1.12.2.2.1.3 | ColumnupsOutletGroupConfigPowerOnDelay | read-write | mandatory | The amount of time (seconds) the outlet group will delay powering on when the delayed on, reboot, or shutdown command is applied. Allowed values vary by UPS mo… |
| 1.3.6.1.4.1.318.1.1.1.12.2.2.1.4 | ColumnupsOutletGroupConfigPowerOffDelay | read-write | mandatory | The amount of time (seconds) the outlet group will delay powering off when the delayed off, reboot, or shutdown command is applied. Allowed values vary by UPS … |
| 1.3.6.1.4.1.318.1.1.1.12.2.2.1.5 | ColumnupsOutletGroupConfigRebootDuration | read-write | mandatory | During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait (seconds) after turning the power off, at the start… |
| 1.3.6.1.4.1.318.1.1.1.12.2.2.1.6 | ColumnupsOutletGroupConfigMinReturnRuntime | read-write | mandatory | In an Outlet Group shutdown sequence, the Outlet Group cycles power off then on. This OID defines the minimum amount of UPS runtime (seconds) that is required … |
| 1.3.6.1.4.1.318.1.1.1.12.2.2.1.7 | ColumnupsOutletGroupConfigOutletType | read-only | mandatory | Getting this variable will return the type of outlet group. If present in the system, the main outlet group is 'unswitched' and must be on in order for any of … |
| 1.3.6.1.4.1.318.1.1.1.12.2.2.1.8 | ColumnupsOutletGroupConfigLoadShedControlSkipOffDelay | read-write | mandatory | Configures whether the outlet group's off delay setting (upsOutletGroupConfigPowerOffDelay) will be used in a load shedding situation, where applicable. |
| 1.3.6.1.4.1.318.1.1.1.12.2.2.1.9 | ColumnupsOutletGroupConfigLoadShedControlAutoRestart | read-write | mandatory | Configures whether the outlet group will automatically restart after a load shedding situation, where applicable. |
| 1.3.6.1.4.1.318.1.1.1.12.2.2.1.10 | ColumnupsOutletGroupConfigLoadShedControlTimeOnBattery | read-write | mandatory | Configures whether the outlet group will load shed (turn off) after the UPS's time on battery has exceeded the upsOutletGroupConfigLoadShedTimeOnBattery OID se… |
| 1.3.6.1.4.1.318.1.1.1.12.2.2.1.11 | ColumnupsOutletGroupConfigLoadShedControlRuntimeRemaining | read-write | mandatory | Configures whether the outlet group will load shed (turn off) when the UPS is on battery and the remaining runtime is less than the upsOutletGroupConfigLoadShe… |
| 1.3.6.1.4.1.318.1.1.1.12.2.2.1.12 | ColumnupsOutletGroupConfigLoadShedControlInOverload | read-write | mandatory | Configures whether the outlet group will load shed (turn off) when the UPS is in an overload condition. The setting for upsOutletGroupConfigLoadShedControlSkip… |
| 1.3.6.1.4.1.318.1.1.1.12.2.2.1.13 | ColumnupsOutletGroupConfigLoadShedTimeOnBattery | read-write | mandatory | When the UPS has been on battery for more time than this value, the outlet group will turn off if this condition is enabled by the upsOutletGroupConfigLoadShed… |
| 1.3.6.1.4.1.318.1.1.1.12.2.2.1.14 | ColumnupsOutletGroupConfigLoadShedRuntimeRemaining | read-write | mandatory | When the runtime remaining is less than this value, the outlet group will turn off if this condition is enabled by the upsOutletGroupConfigLoadShedControlRunti… |
| 1.3.6.1.4.1.318.1.1.1.12.3 | NodeupsOutletGroupControl | |||
| 1.3.6.1.4.1.318.1.1.1.12.3.1 | ScalarupsOutletGroupControlTableSize | read-only | mandatory | The number of outlet groups for the UPS. |
| 1.3.6.1.4.1.318.1.1.1.12.3.2 | TableupsOutletGroupControlTable | not-accessible | mandatory | Allows for control of individual outlet groups. The number of entries is contained in the upsOutletGroupControlTableSize OID. |
| 1.3.6.1.4.1.318.1.1.1.12.3.2.1 | RowupsOutletGroupControlEntry | not-accessible | mandatory | The outlet group to control. |
| 1.3.6.1.4.1.318.1.1.1.12.3.2.1.1 | ColumnupsOutletGroupControlIndex | read-only | mandatory | The index to the outlet group entry. |
| 1.3.6.1.4.1.318.1.1.1.12.3.2.1.2 | ColumnupsOutletGroupControlName | read-only | mandatory | The name of the outlet group. This OID is provided for informational purposes only. This value is set by the upsOutletGroupConfigName OID. |
| 1.3.6.1.4.1.318.1.1.1.12.3.2.1.3 | ColumnupsOutletGroupControlCommand | read-write | mandatory | Getting this variable will return the outlet group state. If the outlet group is on, the upsOutletGroupImmediateOn (1) value will be returned. If the outlet gr… |
| 1.3.6.1.4.1.318.1.1.1.12.3.2.1.4 | ColumnupsOutletGroupControlOutletType | read-only | mandatory | Getting this variable will return the type of outlet group. If present in the system, the main outlet group is 'unswitched' and must be on in order for any of … |
| 1.3.6.1.4.1.318.1.1.1.13 | NodeupsDiagnostics | |||
| 1.3.6.1.4.1.318.1.1.1.13.1 | NodeupsDiagnosticIM | |||
| 1.3.6.1.4.1.318.1.1.1.13.1.1 | ScalarupsDiagIMTableSize | read-only | mandatory | The number of Intelligence Modules in or attached to the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.1.2 | TableupsDiagIMTable | not-accessible | mandatory | Allows for diagnostics of individual Intelligence Modules. The number of entries is contained in the upsDiagIMTableSize OID. |
| 1.3.6.1.4.1.318.1.1.1.13.1.2.1 | RowupsDiagIMEntry | not-accessible | mandatory | The diagnostics and information of an Intelligence Module. |
| 1.3.6.1.4.1.318.1.1.1.13.1.2.1.1 | ColumnupsDiagIMIndex | read-only | mandatory | The index to the Intelligence Module entry. |
| 1.3.6.1.4.1.318.1.1.1.13.1.2.1.2 | ColumnupsDiagIMType | read-only | mandatory | The type of the Intelligence Module. imUnknown(1) indicates the IM type is unknown. imMIM(2) indicates the IM type is a Main Intelligence Module. imRIM(3) indi… |
| 1.3.6.1.4.1.318.1.1.1.13.1.2.1.3 | ColumnupsDiagIMStatus | read-only | mandatory | The status of the Intelligence Module. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indic… |
| 1.3.6.1.4.1.318.1.1.1.13.1.2.1.4 | ColumnupsDiagIMFirmwareRev | read-only | mandatory | The firmware revision of the Intelligence Module. |
| 1.3.6.1.4.1.318.1.1.1.13.1.2.1.5 | ColumnupsDiagIMSlaveFirmwareRev | read-only | mandatory | The slave firmware revision of the Intelligence Module. |
| 1.3.6.1.4.1.318.1.1.1.13.1.2.1.6 | ColumnupsDiagIMHardwareRev | read-only | mandatory | The hardware revision of the Intelligence Module. |
| 1.3.6.1.4.1.318.1.1.1.13.1.2.1.7 | ColumnupsDiagIMSerialNum | read-only | mandatory | The serial number of the Intelligence Module. |
| 1.3.6.1.4.1.318.1.1.1.13.1.2.1.8 | ColumnupsDiagIMManufactureDate | read-only | mandatory | The manufacture date of the Intelligence Module. |
| 1.3.6.1.4.1.318.1.1.1.13.1.2.1.9 | ColumnupsDiagIMInControl | read-only | mandatory | The Intelligence Module state. activeInControl(1) indicates the IM is active and in control. passive(2) indicates the IM is in passive state. unknown(3) indica… |
| 1.3.6.1.4.1.318.1.1.1.13.2 | NodeupsDiagnosticPowerModules | |||
| 1.3.6.1.4.1.318.1.1.1.13.2.1 | ScalarupsDiagPMTableSize | read-only | mandatory | The maximum number of Power Modules supported by the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.2.2 | TableupsDiagPMTable | not-accessible | mandatory | Allows for diagnostics of Individual Power modules. The number of entries is contained in the upsDiagPMTableSize OID. |
| 1.3.6.1.4.1.318.1.1.1.13.2.2.1 | RowupsDiagPMEntry | not-accessible | mandatory | The diagnostics of an Power Module. |
| 1.3.6.1.4.1.318.1.1.1.13.2.2.1.1 | ColumnupsDiagPMIndex | read-only | mandatory | The index to the Power Module entry. |
| 1.3.6.1.4.1.318.1.1.1.13.2.2.1.2 | ColumnupsDiagPMStatus | read-only | mandatory | The status of the Power Module. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates th… |
| 1.3.6.1.4.1.318.1.1.1.13.2.2.1.3 | ColumnupsDiagPMFirmwareRev | read-only | mandatory | The firmware revision of the Power Module. |
| 1.3.6.1.4.1.318.1.1.1.13.2.2.1.4 | ColumnupsDiagPMHardwareRev | read-only | mandatory | The hardware revision of the Power Module. |
| 1.3.6.1.4.1.318.1.1.1.13.2.2.1.5 | ColumnupsDiagPMSerialNum | read-only | mandatory | The serial number of the Power Module. |
| 1.3.6.1.4.1.318.1.1.1.13.2.2.1.6 | ColumnupsDiagPMManufactureDate | read-only | mandatory | The manufacture date of the Power Module. |
| 1.3.6.1.4.1.318.1.1.1.13.2.2.1.7 | ColumnupsDiagPMModelNum | read-only | mandatory | The model number of the Power Module. |
| 1.3.6.1.4.1.318.1.1.1.13.2.3 | TableupsDiagPMLifetimeInfoTable | not-accessible | mandatory | Allows for diagnostics of individual power module's lifetime information. The number of entries is contained in the upsDiagPMTableSize OID. |
| 1.3.6.1.4.1.318.1.1.1.13.2.3.1 | RowupsDiagPMLifetimeInfoEntry | not-accessible | mandatory | The diagnostics of a Power Module lifetime information. |
| 1.3.6.1.4.1.318.1.1.1.13.2.3.1.1 | ColumnupsDiagPMLifetimeInfoIndex | read-only | mandatory | The index to the Power Module lifetime information entry. |
| 1.3.6.1.4.1.318.1.1.1.13.2.3.1.2 | ColumnupsDiagPMLifetimeStatus | read-only | mandatory | The status of the Power Module lifetime information. ok(1) indicates the device lifetime status is OK. nearEnd(2) indicates the device lifetime status is near … |
| 1.3.6.1.4.1.318.1.1.1.13.2.3.1.3 | ColumnupsDiagPMEstmtdLifetimeRmng | read-only | mandatory | Displays the time remaining for the module before it should be replaced. Measured in months. This value is set when you originally install the module. |
| 1.3.6.1.4.1.318.1.1.1.13.2.3.1.4 | ColumnupsDiagPMEstmtdLifetimeRmngPct | read-only | mandatory | Displays the percentage of the total lifetime remaining for the module before it should be replaced. |
| 1.3.6.1.4.1.318.1.1.1.13.2.3.1.5 | ColumnupsDiagPMFanLifetimeStatus | read-only | mandatory | The status of the Power Module Fan lifetime information. ok(1) indicates the device lifetime status is OK. nearEnd(2) indicates the device lifetime status is n… |
| 1.3.6.1.4.1.318.1.1.1.13.2.3.1.6 | ColumnupsDiagPMFanEstmtdLifetimeRmng | read-only | mandatory | Displays the time remaining, measured in months, before the module's fan should be replaced. It is reset by the field service engineer when a new fan is instal… |
| 1.3.6.1.4.1.318.1.1.1.13.2.3.1.7 | ColumnupsDiagPMFanEstmtdLifetimeRmngPct | read-only | mandatory | Displays the percentage of the total lifetime remaining before the module's fan should be replaced. |
| 1.3.6.1.4.1.318.1.1.1.13.2.4 | ScalarupsDiagPMEnclDoorFltrTableSize | read-only | mandatory | The maximum number of power module enclosures attached to the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.2.5 | TableupsDiagPMEnclDoorFltrTable | not-accessible | mandatory | Allows for the diagnostics of individual power module enclosure door filters. The number of entries is contained in the upsDiagPMEnclDoorFltrTableSize OID. |
| 1.3.6.1.4.1.318.1.1.1.13.2.5.1 | RowupsDiagPMEnclDoorFltrEntry | not-accessible | mandatory | Power module door filter diagnostics info. |
| 1.3.6.1.4.1.318.1.1.1.13.2.5.1.1 | ColumnupsDiagPMEnclIndex | read-only | mandatory | The index to the power module enclosure entry. Enclosure 0 indicates the Power enclosure 1. Enclosure 1 indicates the Power enclosure 2. |
| 1.3.6.1.4.1.318.1.1.1.13.2.5.1.2 | ColumnupsDiagPMEnclDoorFltrLifetime | read-only | mandatory | Door filter replacement time interval, based on the installation enivironment. heavyFiltration15days (1) indicates door filter needs to be replaced within 15 d… |
| 1.3.6.1.4.1.318.1.1.1.13.2.5.1.3 | ColumnupsDiagPMEnclDoorFltrStatus | read-only | mandatory | Indicates the current status of the door filter. ok(1) indicates the device lifetime status is OK. nearEnd(2) indicates the device lifetime status is near end.… |
| 1.3.6.1.4.1.318.1.1.1.13.2.5.1.4 | ColumnupsDiagPMEnclDoorFltrEstmtdLifetimeRmng | read-only | mandatory | Displays the time remaining, measured in days, before the module door filter should be replaced. This value is set when you originally install the module. |
| 1.3.6.1.4.1.318.1.1.1.13.2.5.1.5 | ColumnupsDiagPMEnclDoorFltrEstmtdLifetimeRmngPct | read-only | mandatory | Displays the percentage of the total lifetime remaining for the module door filter before it should be replaced. |
| 1.3.6.1.4.1.318.1.1.1.13.3 | NodeupsDiagnosticBatteries | |||
| 1.3.6.1.4.1.318.1.1.1.13.3.1 | ScalarupsDiagBatteryTableSize | read-only | mandatory | The maximum number of batteries supported by the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.3.2 | TableupsDiagBatteryTable | not-accessible | mandatory | Allows for diagnostics of individual batteries. The number of entries is contained in the upsDiagBattTableSize OID. |
| 1.3.6.1.4.1.318.1.1.1.13.3.2.1 | RowupsDiagBatteryEntry | not-accessible | mandatory | The diagnostics of a battery. |
| 1.3.6.1.4.1.318.1.1.1.13.3.2.1.1 | ColumnupsDiagBatteryFrameIndex | read-only | mandatory | The index to the battery frame entry. Frame 0 indicates the Main frame. Extended Run (XR) frames start from index 1. |
| 1.3.6.1.4.1.318.1.1.1.13.3.2.1.2 | ColumnupsDiagBatteryIndex | read-only | mandatory | The index to the battery entry. |
| 1.3.6.1.4.1.318.1.1.1.13.3.2.1.3 | ColumnupsDiagBatteryStatus | read-only | mandatory | The status of the battery. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicates the batter… |
| 1.3.6.1.4.1.318.1.1.1.13.3.2.1.4 | ColumnupsDiagBatterySerialNumber | read-only | mandatory | The serial number of the battery. |
| 1.3.6.1.4.1.318.1.1.1.13.3.2.1.5 | ColumnupsDiagBatteryFirmwareRev | read-only | mandatory | The firmware revision of the battery. |
| 1.3.6.1.4.1.318.1.1.1.13.3.2.1.6 | ColumnupsDiagBatteryManufactureDate | read-only | mandatory | The manufacture date of the battery. |
| 1.3.6.1.4.1.318.1.1.1.13.3.2.1.7 | ColumnupsDiagBatteryType | read-only | mandatory | The battery type or rating for the battery. |
| 1.3.6.1.4.1.318.1.1.1.13.3.2.1.8 | ColumnupsDiagBatteryFramePresent | read-only | mandatory | The battery frame/cabinet status. 0 indicates frame/cabinet is not present. 1 indicates frame/cabinet is present. |
| 1.3.6.1.4.1.318.1.1.1.13.3.2.1.9 | ColumnupsDiagBatteryFrameTemperature | read-only | mandatory | The battery frame/cabinet temperature in tenths of degrees celsius. If the frame/cabinet is not present, this variable is set to (-1). |
| 1.3.6.1.4.1.318.1.1.1.13.3.3 | ScalarupsDiagBatteryFrameTableSize | read-only | mandatory | The maximum number of battery frames supported by the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.3.4 | TableupsDiagBatteryFrameTable | not-accessible | mandatory | Allows for diagnostics of individual battery frame. The number of entries is contained in the upsDiagBatteryFrameTableSize OID. |
| 1.3.6.1.4.1.318.1.1.1.13.3.4.1 | RowupsDiagBatteryFrameEntry | not-accessible | mandatory | The diagnostics of a battery frame. |
| 1.3.6.1.4.1.318.1.1.1.13.3.4.1.1 | ColumnupsDiagBatteryFrameTableIndex | read-only | mandatory | The index to the battery frame entry. |
| 1.3.6.1.4.1.318.1.1.1.13.3.4.1.2 | ColumnupsDiagBatteryModuleStatusPerFrame | read-only | mandatory | An ASCII string containing the 64 flags representing the status of battery modules. 1 indicates battery module installed, 0 indicates battery module not instal… |
| 1.3.6.1.4.1.318.1.1.1.13.3.4.1.3 | ColumnupsDiagBatteryPositiveVoltage | read-only | mandatory | The battery positive voltage, in Volts. |
| 1.3.6.1.4.1.318.1.1.1.13.3.4.1.4 | ColumnupsDiagBatteryNegativeVoltage | read-only | mandatory | The battery negative voltage, in Volts. |
| 1.3.6.1.4.1.318.1.1.1.13.3.4.1.5 | ColumnupsDiagBatteryTemperature | read-only | mandatory | The battery frame/cabinet temperature in tenths of degrees celsius. If the frame/cabinet is not present, this variable is set to (-1). |
| 1.3.6.1.4.1.318.1.1.1.13.4 | NodeupsDiagnosticSubsystem | |||
| 1.3.6.1.4.1.318.1.1.1.13.4.1 | ScalarupsDiagSubSysFrameTableSize | read-only | mandatory | The number of frames attached to the UPS including the Main frame. |
| 1.3.6.1.4.1.318.1.1.1.13.4.2 | TableupsDiagSubSysFrameTable | not-accessible | mandatory | Allows for diagnostics of individual XR Frames. |
| 1.3.6.1.4.1.318.1.1.1.13.4.2.1 | RowupsDiagSubSysFrameEntry | not-accessible | mandatory | The diagnostics of an XR Frame. |
| 1.3.6.1.4.1.318.1.1.1.13.4.2.1.1 | ColumnupsDiagSubSysFrameIndex | read-only | mandatory | The frame index entry. |
| 1.3.6.1.4.1.318.1.1.1.13.4.2.1.2 | ColumnupsDiagSubSysFrameType | read-only | mandatory | The type of Frame. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. frameTypeMain(3) indicates the fra… |
| 1.3.6.1.4.1.318.1.1.1.13.4.2.1.3 | ColumnupsDiagSubSysFrameFirmwareRev | read-only | mandatory | The firmware revision of the frame. |
| 1.3.6.1.4.1.318.1.1.1.13.4.2.1.4 | ColumnupsDiagSubSysFrameHardwareRev | read-only | mandatory | The hardware revision of the frame. |
| 1.3.6.1.4.1.318.1.1.1.13.4.2.1.5 | ColumnupsDiagSubSysFrameSerialNum | read-only | mandatory | The serial number of the frame. |
| 1.3.6.1.4.1.318.1.1.1.13.4.2.1.6 | ColumnupsDiagSubSysFrameManufactureDate | read-only | mandatory | The manufacture date of the frame. |
| 1.3.6.1.4.1.318.1.1.1.13.4.3 | ScalarupsDiagSubSysIntBypSwitchTableSize | read-only | mandatory | The number of Internal Bypass switches attached to the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.4.4 | TableupsDiagSubSysIntBypSwitchTable | not-accessible | mandatory | Allows for diagnostics of the Internal Bypass Switch. |
| 1.3.6.1.4.1.318.1.1.1.13.4.4.1 | RowupsDiagSubSysIntBypSwitchEntry | not-accessible | mandatory | The diagnostics of the Internal Bypass Switch. |
| 1.3.6.1.4.1.318.1.1.1.13.4.4.1.1 | ColumnupsDiagSubSysIntBypSwitchFrameIndex | read-only | mandatory | The frame index entry. |
| 1.3.6.1.4.1.318.1.1.1.13.4.4.1.2 | ColumnupsDiagSubSysIntBypSwitchIndex | read-only | mandatory | The Internal Bypass Switch index entry. |
| 1.3.6.1.4.1.318.1.1.1.13.4.4.1.3 | ColumnupsDiagSubSysIntBypSwitchStatus | read-only | mandatory | The Internal Bypass Switch status. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates… |
| 1.3.6.1.4.1.318.1.1.1.13.4.4.1.4 | ColumnupsDiagSubSysIntBypSwitchFirmwareRev | read-only | mandatory | The firmware revision of the Internal Bypass Switch. |
| 1.3.6.1.4.1.318.1.1.1.13.4.4.1.5 | ColumnupsDiagSubSysIntBypSwitchHardwareRev | read-only | mandatory | The hardware revision of the Internal Bypass Switch. |
| 1.3.6.1.4.1.318.1.1.1.13.4.4.1.6 | ColumnupsDiagSubSysIntBypSwitchSerialNum | read-only | mandatory | The serial number of the Internal Bypass Switch. |
| 1.3.6.1.4.1.318.1.1.1.13.4.4.1.7 | ColumnupsDiagSubSysIntBypSwitchManufactureDate | read-only | mandatory | The manufacture date of the Internal Bypass Switch. |
| 1.3.6.1.4.1.318.1.1.1.13.4.4.1.8 | ColumnupsDiagSubSysIntBypSwitchModelNum | read-only | mandatory | The model number of the Internal Bypass Switch. |
| 1.3.6.1.4.1.318.1.1.1.13.4.5 | ScalarupsDiagSubSysBattMonitorTableSize | read-only | mandatory | The number of Battery Monitor Boards attached to the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.4.6 | TableupsDiagSubSysBattMonitorTable | not-accessible | mandatory | Allows for diagnostics of the Battery Monitor Board. |
| 1.3.6.1.4.1.318.1.1.1.13.4.6.1 | RowupsDiagSubSysBattMonitorEntry | not-accessible | mandatory | The diagnostics of the Battery Monitor Board. |
| 1.3.6.1.4.1.318.1.1.1.13.4.6.1.1 | ColumnupsDiagSubSysBattMonitorFrameIndex | read-only | mandatory | The frame index entry. |
| 1.3.6.1.4.1.318.1.1.1.13.4.6.1.2 | ColumnupsDiagSubSysBattMonitorIndex | read-only | mandatory | The index of the Battery Monitor Board. |
| 1.3.6.1.4.1.318.1.1.1.13.4.6.1.3 | ColumnupsDiagSubSysBattMonitorStatus | read-only | mandatory | The status of the Battery Monitor Board. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) ind… |
| 1.3.6.1.4.1.318.1.1.1.13.4.6.1.4 | ColumnupsDiagSubSysBattMonitorFirmwareRev | read-only | mandatory | The firmware revision of the Battery Monitor Board. |
| 1.3.6.1.4.1.318.1.1.1.13.4.6.1.5 | ColumnupsDiagSubSysBattMonitorHardwareRev | read-only | mandatory | The hardware revision of the Battery Monitor Board. |
| 1.3.6.1.4.1.318.1.1.1.13.4.6.1.6 | ColumnupsDiagSubSysBattMonitorSerialNum | read-only | mandatory | The serial number of the Battery Monitor Board. |
| 1.3.6.1.4.1.318.1.1.1.13.4.6.1.7 | ColumnupsDiagSubSysBattMonitorManufactureDate | read-only | mandatory | The date of the manufacture for the Battery Monitor Board. |
| 1.3.6.1.4.1.318.1.1.1.13.4.7 | ScalarupsDiagSubSysExternalSwitchGearTableSize | read-only | mandatory | The number of External Switch Gears attached to the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.4.8 | TableupsDiagSubSysExternalSwitchGearTable | not-accessible | mandatory | Allows for diagnostics of the individual External Switch Gear. |
| 1.3.6.1.4.1.318.1.1.1.13.4.8.1 | RowupsDiagSubSysExternalSwitchGearEntry | not-accessible | mandatory | The diagnostics of an individual External Switch Gear. |
| 1.3.6.1.4.1.318.1.1.1.13.4.8.1.1 | ColumnupsDiagSubSysExternalSwitchGearFrameIndex | read-only | mandatory | The frame index entry. |
| 1.3.6.1.4.1.318.1.1.1.13.4.8.1.2 | ColumnupsDiagSubSysExternalSwitchGearIndex | read-only | mandatory | The index of the External Switch Gear. |
| 1.3.6.1.4.1.318.1.1.1.13.4.8.1.3 | ColumnupsDiagSubSysExternalSwitchGearStatus | read-only | mandatory | The status of the External Switch Gear. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indi… |
| 1.3.6.1.4.1.318.1.1.1.13.4.8.1.4 | ColumnupsDiagSubSysExternalSwitchGearFirmwareRev | read-only | mandatory | The firmware revision of the External Switch Gear monitor card. |
| 1.3.6.1.4.1.318.1.1.1.13.4.8.1.5 | ColumnupsDiagSubSysExternalSwitchGearHardwareRev | read-only | mandatory | The hardware revision of the External Switch Gear monitor card. |
| 1.3.6.1.4.1.318.1.1.1.13.4.8.1.6 | ColumnupsDiagSubSysExternalSwitchGearSerialNum | read-only | mandatory | The serial number of the External Switch Gear monitor card. |
| 1.3.6.1.4.1.318.1.1.1.13.4.8.1.7 | ColumnupsDiagSubSysExternalSwitchGearManufactureDate | read-only | mandatory | The date of the manufacture for the External Switch Gear monitor card. |
| 1.3.6.1.4.1.318.1.1.1.13.4.8.1.8 | ColumnupsDiagSubSysExternalSwitchGearTemperature | read-only | mandatory | The temperature of the air around the External Switch Gear monitor card in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.1.13.4.9 | ScalarupsDiagSubSysDisplayInterfaceCardTableSize | read-only | mandatory | The number of Display Interface Cards attached to the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.4.10 | TableupsDiagSubSysDisplayInterfaceCardTable | not-accessible | mandatory | Allows for diagnostics of individual Display Interface Cards. |
| 1.3.6.1.4.1.318.1.1.1.13.4.10.1 | RowupsDiagSubSysDisplayInterfaceCardEntry | not-accessible | mandatory | The diagnostics of a Display Interface Card. |
| 1.3.6.1.4.1.318.1.1.1.13.4.10.1.1 | ColumnupsDiagSubSysDisplayInterfaceCardFrameIndex | read-only | mandatory | The frame index entry. |
| 1.3.6.1.4.1.318.1.1.1.13.4.10.1.2 | ColumnupsDiagSubSysDisplayInterfaceCardIndex | read-only | mandatory | The index of the Display Interface Card. |
| 1.3.6.1.4.1.318.1.1.1.13.4.10.1.3 | ColumnupsDiagSubSysDisplayInterfaceCardStatus | read-only | mandatory | The status of the Display Interface Card. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) in… |
| 1.3.6.1.4.1.318.1.1.1.13.4.11 | ScalarupsDiagSubSysDCCircuitBreakerTableSize | read-only | mandatory | The number of DC Circuit Breakers attached to the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.4.12 | TableupsDiagSubSysDCCircuitBreakerTable | not-accessible | mandatory | Allows for diagnostics of individual DC Circuit Breakers. |
| 1.3.6.1.4.1.318.1.1.1.13.4.12.1 | RowupsDiagSubSysDCCircuitBreakerEntry | not-accessible | mandatory | The diagnostics of a DC Circuit Breaker. |
| 1.3.6.1.4.1.318.1.1.1.13.4.12.1.1 | ColumnupsDiagSubSysDCCircuitBreakerFrameIndex | read-only | mandatory | The frame index entry. |
| 1.3.6.1.4.1.318.1.1.1.13.4.12.1.2 | ColumnupsDiagSubSysDCCircuitBreakerIndex | read-only | mandatory | The index of the DC Circuit Breaker. |
| 1.3.6.1.4.1.318.1.1.1.13.4.12.1.3 | ColumnupsDiagSubSysDCCircuitBreakerStatus | read-only | mandatory | The status of the DC Circuit Breaker. unknown(1) indicates the circuit breaker status is unknown. notInstalled(2) indicates the circuit breaker is not installe… |
| 1.3.6.1.4.1.318.1.1.1.13.4.13 | ScalarupsDiagSubSysSystemPowerSupplyTableSize | read-only | mandatory | The number of System Power Supplies attached to the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.4.14 | TableupsDiagSubSysSystemPowerSupplyTable | not-accessible | mandatory | Allows for diagnostics of individual System Power Supplies. |
| 1.3.6.1.4.1.318.1.1.1.13.4.14.1 | RowupsDiagSubSysSystemPowerSupplyEntry | not-accessible | mandatory | The diagnostics of a System Power Supply. |
| 1.3.6.1.4.1.318.1.1.1.13.4.14.1.1 | ColumnupsDiagSubSysSystemPowerSupplyFrameIndex | read-only | mandatory | The frame index entry. |
| 1.3.6.1.4.1.318.1.1.1.13.4.14.1.2 | ColumnupsDiagSubSysSystemPowerSupplyIndex | read-only | mandatory | The index of a System Power Supply. |
| 1.3.6.1.4.1.318.1.1.1.13.4.14.1.3 | ColumnupsDiagSubSysSystemPowerSupplyStatus | read-only | mandatory | The status of the System Power Supply. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indic… |
| 1.3.6.1.4.1.318.1.1.1.13.4.14.1.4 | ColumnupsDiagSubSysSystemPowerSupplyFirmwareRev | read-only | mandatory | The firmware revision of the System Power Supply monitor card. |
| 1.3.6.1.4.1.318.1.1.1.13.4.14.1.5 | ColumnupsDiagSubSysSystemPowerSupplyHardwareRev | read-only | mandatory | The hardware revision of the System Power Supply monitor card. |
| 1.3.6.1.4.1.318.1.1.1.13.4.14.1.6 | ColumnupsDiagSubSysSystemPowerSupplySerialNum | read-only | mandatory | The serial number of the System Power Supply monitor card. |
| 1.3.6.1.4.1.318.1.1.1.13.4.14.1.7 | ColumnupsDiagSubSysSystemPowerSupplyManufactureDate | read-only | mandatory | The date of the manufacture for the System Power Supply monitor card. |
| 1.3.6.1.4.1.318.1.1.1.13.4.15 | ScalarupsDiagSubSysXRCommunicationCardTableSize | read-only | mandatory | The number of XR Communication Cards attached to the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.4.16 | TableupsDiagSubSysXRCommunicationCardTable | not-accessible | mandatory | Allows for diagnostics of individual XR Communication Cards. |
| 1.3.6.1.4.1.318.1.1.1.13.4.16.1 | RowupsDiagSubSysXRCommunicationCardEntry | not-accessible | mandatory | The diagnostics of an XR Communication Card. |
| 1.3.6.1.4.1.318.1.1.1.13.4.16.1.1 | ColumnupsDiagSubSysXRCommunicationCardFrameIndex | read-only | mandatory | The frame index entry. |
| 1.3.6.1.4.1.318.1.1.1.13.4.16.1.2 | ColumnupsDiagSubSysXRCommunicationCardIndex | read-only | mandatory | The index of an XR Communication Card. |
| 1.3.6.1.4.1.318.1.1.1.13.4.16.1.3 | ColumnupsDiagSubSysXRCommunicationCardStatus | read-only | mandatory | The status of the XR Communication Card. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) ind… |
| 1.3.6.1.4.1.318.1.1.1.13.4.16.1.4 | ColumnupsDiagSubSysXRCommunicationCardFirmwareRev | read-only | mandatory | The firmware revision of the XR Communication card. |
| 1.3.6.1.4.1.318.1.1.1.13.4.16.1.5 | ColumnupsDiagSubSysXRCommunicationCardSerialNum | read-only | mandatory | The serial number of the XR Communication card. |
| 1.3.6.1.4.1.318.1.1.1.13.4.17 | ScalarupsDiagSubSysExternalPowerFrameBoardTableSize | read-only | mandatory | The number of External Power Frame Boards attached to the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.4.18 | TableupsDiagSubSysExternalPowerFrameBoardTable | not-accessible | mandatory | Allows for diagnostics of individual External Power Frame Boards. |
| 1.3.6.1.4.1.318.1.1.1.13.4.18.1 | RowupsDiagSubSysExternalPowerFrameBoardEntry | not-accessible | mandatory | The diagnostics of an External Power Frame Board. |
| 1.3.6.1.4.1.318.1.1.1.13.4.18.1.1 | ColumnupsDiagSubSysExternalPowerFrameBoardFrameIndex | read-only | mandatory | The frame index entry. |
| 1.3.6.1.4.1.318.1.1.1.13.4.18.1.2 | ColumnupsDiagSubSysExternalPowerFrameBoardIndex | read-only | mandatory | The index of an External Power Frame Board. |
| 1.3.6.1.4.1.318.1.1.1.13.4.18.1.3 | ColumnupsDiagSubSysExternalPowerFrameBoardStatus | read-only | mandatory | The status of the External Power Frame Board. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3… |
| 1.3.6.1.4.1.318.1.1.1.13.4.19 | ScalarupsDiagSubSysChargerTableSize | read-only | mandatory | The number of Chargers attached to the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.4.20 | TableupsDiagSubSysChargerTable | not-accessible | mandatory | Allows for diagnostics of individual chargers. |
| 1.3.6.1.4.1.318.1.1.1.13.4.20.1 | RowupsDiagSubSysChargerEntry | not-accessible | mandatory | The diagnostics of a charger. |
| 1.3.6.1.4.1.318.1.1.1.13.4.20.1.1 | ColumnupsDiagSubSysChargerFrameIndex | read-only | mandatory | The frame index entry. |
| 1.3.6.1.4.1.318.1.1.1.13.4.20.1.2 | ColumnupsDiagSubSysChargerIndex | read-only | mandatory | The index of a charger. |
| 1.3.6.1.4.1.318.1.1.1.13.4.20.1.3 | ColumnupsDiagSubSysChargerStatus | read-only | mandatory | The status of the Charger. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the dev… |
| 1.3.6.1.4.1.318.1.1.1.13.4.21 | ScalarupsDiagSubSysInverterTableSize | read-only | mandatory | The number of Inverters attached to the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.4.22 | TableupsDiagSubSysInverterTable | not-accessible | mandatory | Allows for diagnostics of individual Inverters. |
| 1.3.6.1.4.1.318.1.1.1.13.4.22.1 | RowupsDiagSubSysInverterEntry | not-accessible | mandatory | The diagnostics of an Inverter. |
| 1.3.6.1.4.1.318.1.1.1.13.4.22.1.1 | ColumnupsDiagSubSysInverterFrameIndex | read-only | mandatory | The frame index entry. |
| 1.3.6.1.4.1.318.1.1.1.13.4.22.1.2 | ColumnupsDiagSubSysInverterIndex | read-only | mandatory | The index of an Inverter. |
| 1.3.6.1.4.1.318.1.1.1.13.4.22.1.3 | ColumnupsDiagSubSysInverterStatus | read-only | mandatory | The status of the Inverter. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the de… |
| 1.3.6.1.4.1.318.1.1.1.13.4.22.1.4 | ColumnupsDiagSubSysInverterFirmwareRev | read-only | mandatory | The firmware revision of the Inverter monitor. |
| 1.3.6.1.4.1.318.1.1.1.13.4.22.1.5 | ColumnupsDiagSubSysInverterHardwareRev | read-only | mandatory | The hardware revision of the Inverter monitor. |
| 1.3.6.1.4.1.318.1.1.1.13.4.22.1.6 | ColumnupsDiagSubSysInverterSerialNum | read-only | mandatory | The serial number of the Inverter monitor. |
| 1.3.6.1.4.1.318.1.1.1.13.4.22.1.7 | ColumnupsDiagSubSysInverterManufactureDate | read-only | mandatory | The date of manufacture for the Inverter monitor. |
| 1.3.6.1.4.1.318.1.1.1.13.4.23 | ScalarupsDiagSubSysPowerFactorCorrectionTableSize | read-only | mandatory | The number of Power Factor Correction devices attached to the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.4.24 | TableupsDiagSubSysPowerFactorCorrectionTable | not-accessible | mandatory | Allows for diagnostics of individual PowerFactorCorrections. |
| 1.3.6.1.4.1.318.1.1.1.13.4.24.1 | RowupsDiagSubSysPowerFactorCorrectionEntry | not-accessible | mandatory | The diagnostics of a Power Factor Correction. |
| 1.3.6.1.4.1.318.1.1.1.13.4.24.1.1 | ColumnupsDiagSubSysPowerFactorCorrectionFrameIndex | read-only | mandatory | The frame index entry. |
| 1.3.6.1.4.1.318.1.1.1.13.4.24.1.2 | ColumnupsDiagSubSysPowerFactorCorrectionIndex | read-only | mandatory | The index of a Power Factor Correction. |
| 1.3.6.1.4.1.318.1.1.1.13.4.24.1.3 | ColumnupsDiagSubSysPowerFactorCorrectionStatus | read-only | mandatory | The status of the Power Factor Correction. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) i… |
| 1.3.6.1.4.1.318.1.1.1.13.4.24.1.4 | ColumnupsDiagSubSysPowerFactorCorrectionFirmwareRev | read-only | mandatory | The firmware revision of the Power Factor Correction monitor. |
| 1.3.6.1.4.1.318.1.1.1.13.4.24.1.5 | ColumnupsDiagSubSysPowerFactorCorrectionHardwareRev | read-only | mandatory | The hardware revision of the Power Factor Correction monitor. |
| 1.3.6.1.4.1.318.1.1.1.13.4.24.1.6 | ColumnupsDiagSubSysPowerFactorCorrectionSerialNum | read-only | mandatory | The serial number of the Power Factor Correction monitor. |
| 1.3.6.1.4.1.318.1.1.1.13.4.24.1.7 | ColumnupsDiagSubSysPowerFactorCorrectionManufactureDate | read-only | mandatory | The date of the manufacture for the Power Factor Correction monitor. |
| 1.3.6.1.4.1.318.1.1.1.13.4.25 | ScalarupsDiagSubSysNetworkComCardTableSize | read-only | mandatory | The number of Network Communication Cards attached to the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.4.26 | TableupsDiagSubSysNetworkComCardTable | not-accessible | mandatory | Allows for getting diagnostics information of an individual Network Communication Card. |
| 1.3.6.1.4.1.318.1.1.1.13.4.26.1 | RowupsDiagSubSysNetworkComCardEntry | not-accessible | mandatory | The diagnostics of a Network Communication Card. |
| 1.3.6.1.4.1.318.1.1.1.13.4.26.1.1 | ColumnupsDiagSubSysNetworkComCardIndex | read-only | mandatory | The UPS network and display interface communication card index entry. |
| 1.3.6.1.4.1.318.1.1.1.13.4.26.1.2 | ColumnupsDiagSubSysNetworkComCardModelNumber | read-only | mandatory | A character string identifying the model number of the UPS network and display interface communication card. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.1.13.4.26.1.3 | ColumnupsDiagSubSysNetworkComCardSerialNumber | read-only | mandatory | A character string identifying the serial number of the UPS network and display interface communication card. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.1.13.4.26.1.4 | ColumnupsDiagSubSysNetworkComCardDateOfManufacture | read-only | mandatory | The date when the UPS network and display interface communication card was manufactured in mm/dd/yyyy format. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.1.13.4.26.1.5 | ColumnupsDiagSubSysNetworkComCardHardwareRev | read-only | mandatory | The hardware revision of the UPS network and display interface communication card. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.1.13.4.26.1.6 | ColumnupsDiagSubSysNetworkComCardFirmwareAppRev | read-only | mandatory | An ID string identifying the application firmware revision of the UPS network and display interface communication card. |
| 1.3.6.1.4.1.318.1.1.1.13.4.26.1.7 | ColumnupsDiagSubSysNetworkComCardFirmwareAppOSRev | read-only | mandatory | An ID string identifying the application operating system firmware revision of the UPS network and display interface communication card. |
| 1.3.6.1.4.1.318.1.1.1.13.4.27 | ScalarupsDiagSubSysUsrSuppBattMonitorTableSize | read-only | mandatory | The number of user supplied Battery Monitor Boards attached to the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.4.28 | TableupsDiagSubSysUsrSuppBattMonitorTable | not-accessible | mandatory | Allows for diagnostics of the user supplied Battery Monitor Board. |
| 1.3.6.1.4.1.318.1.1.1.13.4.28.1 | RowupsDiagSubSysUsrSuppBattMonitorEntry | not-accessible | mandatory | The diagnostics of the user supplied Battery Monitor Board. |
| 1.3.6.1.4.1.318.1.1.1.13.4.28.1.1 | ColumnupsDiagSubSysUsrSuppBattMonitorIndex | read-only | mandatory | The index of the user supplied Battery Monitor Board. |
| 1.3.6.1.4.1.318.1.1.1.13.4.28.1.2 | ColumnupsDiagSubSysUsrSuppBattMonitorStatus | read-only | mandatory | The status of the user supplied Battery Monitor Board. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed… |
| 1.3.6.1.4.1.318.1.1.1.13.4.28.1.3 | ColumnupsDiagSubSysUsrSuppBattMonitorFirmwareRev | read-only | mandatory | The firmware revision of the user supplied Battery Monitor Board. |
| 1.3.6.1.4.1.318.1.1.1.13.4.28.1.4 | ColumnupsDiagSubSysUsrSuppBattMonitorHardwareRev | read-only | mandatory | The hardware revision of the user supplied Battery Monitor Board. |
| 1.3.6.1.4.1.318.1.1.1.13.4.28.1.5 | ColumnupsDiagSubSysUsrSuppBattMonitorSerialNum | read-only | mandatory | The serial number of the user supplied Battery Monitor Board. |
| 1.3.6.1.4.1.318.1.1.1.13.4.28.1.6 | ColumnupsDiagSubSysUsrSuppBattMonitorTemperature | read-only | mandatory | The temperature of the air around the user supplied Battery Monitor Board in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.1.13.4.29 | ScalarupsDiagSubSysUsrSuppBattBreakerStatus | read-only | mandatory | The status of the user supplied Battery Breaker. unknown(1) indicates the circuit breaker status is unknown. notInstalled(2) indicates the circuit breaker is n… |
| 1.3.6.1.4.1.318.1.1.1.13.4.30 | ScalarupsDiagSubSysPSUTableSize | read-only | mandatory | The number of Power Supply Units in the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.4.31 | TableupsDiagSubSysPSUTable | not-accessible | mandatory | Allows for diagnostics of individual Power Supply Units. The number of entries is contained in the upsDiagSubSysPSUTableSize OID. |
| 1.3.6.1.4.1.318.1.1.1.13.4.31.1 | RowupsDiagSubSysPSUEntry | not-accessible | mandatory | The diagnostics information of a Power Supply Unit. |
| 1.3.6.1.4.1.318.1.1.1.13.4.31.1.1 | ColumnupsDiagSubSysPSUIndex | read-only | mandatory | The index to the Power Supply Unit entry. |
| 1.3.6.1.4.1.318.1.1.1.13.4.31.1.2 | ColumnupsDiagSubSysPSUStatus | read-only | mandatory | The status of the Power Supply Unit. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicat… |
| 1.3.6.1.4.1.318.1.1.1.13.4.32 | ScalarupsDiagSubSysIDRCTableSize | read-only | mandatory | The number of ID and Relay Controller Cards attached to the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.4.33 | TableupsDiagSubSysIDRCTable | not-accessible | mandatory | Allows for diagnostics of the ID and Relay Controller Card. |
| 1.3.6.1.4.1.318.1.1.1.13.4.33.1 | RowupsDiagSubSysIDRCEntry | not-accessible | mandatory | The diagnostics of the ID and Relay Controller Card. |
| 1.3.6.1.4.1.318.1.1.1.13.4.33.1.1 | ColumnupsDiagSubSysIDRCIndex | read-only | mandatory | The index of the ID and Relay Controller Card. |
| 1.3.6.1.4.1.318.1.1.1.13.4.33.1.2 | ColumnupsDiagSubSysIDRCStatus | read-only | mandatory | The status of the ID and Relay Controller Card. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk… |
| 1.3.6.1.4.1.318.1.1.1.13.4.33.1.3 | ColumnupsDiagSubSysIDRCFirmwareRev | read-only | mandatory | The firmware revision of the ID and Relay Controller Card. |
| 1.3.6.1.4.1.318.1.1.1.13.4.33.1.4 | ColumnupsDiagSubSysIDRCHardwareRev | read-only | mandatory | The hardware revision of the ID and Relay Controller Card. |
| 1.3.6.1.4.1.318.1.1.1.13.4.33.1.5 | ColumnupsDiagSubSysIDRCSerialNum | read-only | mandatory | The serial number of the ID and Relay Controller Card. |
| 1.3.6.1.4.1.318.1.1.1.13.4.34 | ScalarupsDiagSubSysExternalConnectorStatus | read-only | mandatory | The status of the external connector board. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) … |
| 1.3.6.1.4.1.318.1.1.1.13.4.35 | ScalarupsDiagSubSysBackfeedContactorTableSize | read-only | mandatory | The number of backfeed protection contactor attached to the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.4.36 | TableupsDiagSubSysBackfeedContactorTable | not-accessible | mandatory | Backfeed protection contactor table. |
| 1.3.6.1.4.1.318.1.1.1.13.4.36.1 | RowupsDiagSubSysBackfeedContactorEntry | not-accessible | mandatory | A list of backfeed protection contactors. |
| 1.3.6.1.4.1.318.1.1.1.13.4.36.1.1 | ColumnupsDiagSubSysbackfeedContactorIndex | read-only | mandatory | The index of the backfeed protection contactor. |
| 1.3.6.1.4.1.318.1.1.1.13.4.36.1.2 | ColumnupsDiagSubSysbackfeedContactorName | read-write | mandatory | The name of the backfeed protection contactor. |
| 1.3.6.1.4.1.318.1.1.1.13.4.36.1.3 | ColumnupsDiagSubSysbackfeedContactorType | read-only | mandatory | Indicates the backfeed protection contactor types available in the UPS system. If the UPS is unable to find any attached contactors, this variable is set to un… |
| 1.3.6.1.4.1.318.1.1.1.13.4.36.1.4 | ColumnupsDiagSubSysbackfeedContactorStatus | read-only | mandatory | The status of backfeed protection contactor. unknown(1) indicates the contactor status is unknown. opened (2) indicates the contactor is opened. closed (3) ind… |
| 1.3.6.1.4.1.318.1.1.1.13.4.37 | ScalarupsDiagSubSysIntBypSwitchFanLifetimeInfoTableSize | read-only | mandatory | The number of backfeed protection contactor attached to the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.4.38 | TableupsDiagSubSysIntBypSwitchFanLifetimeInfoTable | not-accessible | mandatory | Allows for diagnostics of the Internal Bypass Switch life time infomation. |
| 1.3.6.1.4.1.318.1.1.1.13.4.38.1 | RowupsDiagSubSysIntBypSwitchFanLifetimeInfoEntry | not-accessible | mandatory | The diagnostics of the Internal Bypass Switch. |
| 1.3.6.1.4.1.318.1.1.1.13.4.38.1.1 | ColumnupsDiagSubSysIntBypSwitchFanLifetimeInfoIndex | read-only | mandatory | The index to the Internal Bypass Switch Fan liftime information entry |
| 1.3.6.1.4.1.318.1.1.1.13.4.38.1.2 | ColumnupsDiagSubSysIntBypSwitchFanLifetimeStatus | read-only | mandatory | The status of the Internal Bypass Switch Fan lifetime information. ok(1) indicates the device lifetime status is OK. nearEnd(2) indicates the device lifetime s… |
| 1.3.6.1.4.1.318.1.1.1.13.4.38.1.3 | ColumnupsDiagSubSysIntBypSwitchFanEstmtdLifetimeRmng | read-only | mandatory | Displays the time remaining for the module before it should be replaced. Measured in months. This value is set when you originally install the module. |
| 1.3.6.1.4.1.318.1.1.1.13.4.38.1.4 | ColumnupsDiagSubSysIntBypSwitchFanEstmtdLifetimeRmngPct | read-only | mandatory | Displays the percentage of the total lifetime remaining for the module before it should be replaced. |
| 1.3.6.1.4.1.318.1.1.1.13.5 | NodeupsDiagnosticExternalDevices | |||
| 1.3.6.1.4.1.318.1.1.1.13.5.1 | NodeupsDiagSwitchGear | |||
| 1.3.6.1.4.1.318.1.1.1.13.5.1.1 | ScalarupsDiagSwitchGearStatus | read-only | mandatory | The status of the Switch Gear. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicates the de… |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.2 | ScalarupsDiagSwitchGearInputSwitchStatus | read-only | mandatory | The status of the Switch Gear Input Switch. unknown(1) indicates the switch status is unknown. notInstalled(2) indicates the switch is not installed. opened(3)… |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.3 | ScalarupsDiagSwitchGearOutputSwitchStatus | read-only | mandatory | The status of the Switch Gear Output Switch. unknown(1) indicates the switch status is unknown. notInstalled(2) indicates the switch is not installed. opened(3… |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.4 | ScalarupsDiagSwitchGearBypassSwitchStatus | read-only | mandatory | The status of the Switch Gear Bypass Switch. unknown(1) indicates the switch status is unknown. notInstalled(2) indicates the switch is not installed. opened(3… |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.5 | ScalarupsDiagSwitchGearBypassInputSwitchStatus | read-only | mandatory | The status of the Switch Gear Bypass Input Switch. unknown(1) indicates the switch status is unknown. notInstalled(2) indicates the switch is not installed. op… |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.6 | ScalarupsDiagSwitchGearBreakerTableSize | read-only | mandatory | The number of switchgear breakers attached to the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.7 | TableupsDiagSwitchGearBreakerTable | not-accessible | mandatory | Switchgear breaker table. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.7.1 | RowupsDiagSwitchGearBreakerEntry | not-accessible | mandatory | A list of switchgear breakers. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.7.1.1 | ColumnswitchgearBreakerIndex | read-only | mandatory | The index of the switchgear breaker. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.7.1.2 | ColumnswitchgearBreakerPresent | read-only | mandatory | Indicates if the switchgear breaker is present. notPresent(1) indicates that the breaker is not present. present(2) indicates that the breaker is present. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.7.1.3 | ColumnswitchgearBreakerName | read-write | mandatory | The name of the switchgear breaker. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.7.1.4 | ColumnswitchgearBreakerType | read-only | mandatory | Indicates the switchgear breaker types available in the UPS system. If the UPS is unable to find any attached breakers, this variable is set to unknown(1). |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.7.1.5 | ColumnswitchgearBreakerStatus | read-only | mandatory | The status of switchgear breaker. unknown(1) indicates the breaker status is unknown. opened (2) indicates the breaker is opened. closed (3) indicates the brea… |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.8 | ScalarupsDiagSubFeedBreakerTableSize | read-only | mandatory | The number of subfeed breakers attached to the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.9 | TableupsDiagSubFeedBreakerTable | not-accessible | mandatory | Subfeed breaker table. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.9.1 | RowupsDiagSubFeedBreakerEntry | not-accessible | mandatory | A list of subfeed breakers. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.1 | ColumnsubfeedBreakerIndex | read-only | mandatory | The index of the subfeed breakers. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.2 | ColumnsubfeedBreakerPresent | read-only | mandatory | Indicates if the subfeed breaker is present. notPresent (1) indicates that the breaker is not present. present (2) indicates that the breaker is present. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.3 | ColumnsubfeedBreakerRating | read-only | mandatory | The current rating of the installed subfeed breaker. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.4 | ColumnsubfeedBreakerUpperAcceptPowerWarning | read-write | mandatory | The maximum acceptable load before warning is issued. Expressed as percent of the subfeed breaker rating. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.5 | ColumnsubfeedBreakerUpperAcceptPowerCritical | read-write | mandatory | The maximum load before a critical alarm occurs. Expressed as percent of the subfeed breaker rating. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.6 | ColumnsubfeedBreakerStatus | read-only | mandatory | The status of the Circuit Breaker. unknown(1) indicates the circuit breaker status is unknown. notInstalled(2) indicates the circuit breaker is not installed. … |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.7 | ColumnsubfeedBreakerName | read-write | mandatory | The name of the subfeed breaker. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.8 | ColumnsubfeedBreakerCurrent | read-only | mandatory | The subfeed current in tenths of Amps. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.10 | ScalarupsDiagSwitchGearInstallationLoadPct | read-only | mandatory | The actual output load expressed as a percentage of the rating of the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.11 | TableupsDiagSubFeedPhaseTable | not-accessible | mandatory | A list of subfeed phase table. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.11.1 | RowupsDiagSubFeedPhaseEntry | not-accessible | mandatory | An entry containing information applicable to a particular phase. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.11.1.1 | ColumnupsDiagSubFeedBreakerIndex | read-only | mandatory | The subfeed breaker index. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.11.1.2 | ColumnupsDiagSubFeedPhaseIndex | read-only | mandatory | The subfeed phase index. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.11.1.3 | ColumnupsDiagSubFeedPhaseCurrent | read-only | mandatory | The subfeed phase current in Amps. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.11.1.4 | ColumnupsDiagSubFeedPhaseCurrentAlternate | read-only | mandatory | The subfeed phase current in tenths of Amps. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.12 | ScalarupsDiagSwitchgearSerialNumber | read-only | mandatory | The serial number of the UPS I/O Cabinet. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.13 | ScalarupsDiagSwitchgearAmbientTemperature | read-only | mandatory | The ambient temperature of I/O Cabinet in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.14 | ScalarupsDiagUsrSuppSwitchgearMonitorTableSize | read-only | mandatory | The number of user supplied Switch Gear Monitor Boards attached to the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.15 | TableupsDiagUsrSuppSwitchgearMonitorTable | not-accessible | mandatory | Allows for diagnostics of the user supplied Switch Gear Monitor Board. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.15.1 | RowupsDiagUsrSuppSwitchgearMonitorEntry | not-accessible | mandatory | The diagnostics of the user supplied Switch Gear Monitor Board. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.15.1.1 | ColumnupsDiagUsrSuppSwitchgearMonitorIndex | read-only | mandatory | The index of the user supplied Switch Gear Monitor Board. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.15.1.2 | ColumnupsDiagUsrSuppSwitchgearMonitorStatus | read-only | mandatory | The status of the user supplied Switch Gear Monitor Board. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not insta… |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.15.1.3 | ColumnupsDiagUsrSuppSwitchgearMonitorFirmwareRev | read-only | mandatory | The firmware revision of the user supplied Switch Gear Monitor Board. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.15.1.4 | ColumnupsDiagUsrSuppSwitchgearMonitorHardwareRev | read-only | mandatory | The hardware revision of the user supplied Switch Gear Monitor Board. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.15.1.5 | ColumnupsDiagUsrSuppSwitchgearMonitorSerialNum | read-only | mandatory | The serial number of the user supplied Switch Gear Monitor Board. |
| 1.3.6.1.4.1.318.1.1.1.13.5.1.15.1.6 | ColumnupsDiagUsrSuppSwitchgearMonitorTemperature | read-only | mandatory | The temperature of the air around the user supplied Switch Gear Monitor Board in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.1.13.5.2 | NodeupsDiagMCCBBox | |||
| 1.3.6.1.4.1.318.1.1.1.13.5.2.1 | ScalarupsDiagMCCBBoxStatus | read-only | mandatory | The status of the MCCB Box (Molded Case Circuit Breaker Box) external device. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the … |
| 1.3.6.1.4.1.318.1.1.1.13.5.3 | NodeupsDiagTransformer | |||
| 1.3.6.1.4.1.318.1.1.1.13.5.3.1 | ScalarupsDiagTransformerStatus | read-only | mandatory | The status of the External Transformer. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicat… |
| 1.3.6.1.4.1.318.1.1.1.13.5.4 | NodeupsDiagFlyWheel | |||
| 1.3.6.1.4.1.318.1.1.1.13.5.4.1 | ScalarupsDiagFlyWheelStatus | read-only | mandatory | Indicates the status of flywheel connected to UPS. If the UPS is unable to determine the state of flywheel, this variable is set to unknown(1). |
| 1.3.6.1.4.1.318.1.1.1.13.6 | NodeupsDiagnosticComBus | |||
| 1.3.6.1.4.1.318.1.1.1.13.6.1 | ScalarupsDiagComBusInternalMIMStatus | read-only | mandatory | The status of the internal MIM communication bus. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(… |
| 1.3.6.1.4.1.318.1.1.1.13.6.2 | ScalarupsDiagComBusInternalRIMStatus | read-only | mandatory | The status of the internal RIM communication bus. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(… |
| 1.3.6.1.4.1.318.1.1.1.13.6.3 | ScalarupsDiagComBusMIMtoRIMStatus | read-only | mandatory | The status of the MIM to RIM communication bus. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3)… |
| 1.3.6.1.4.1.318.1.1.1.13.6.4 | ScalarupsDiagComBusExternalMIMStatus | read-only | mandatory | The status of the external MIM communication bus. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(… |
| 1.3.6.1.4.1.318.1.1.1.13.6.5 | ScalarupsDiagComBusExternalRIMStatus | read-only | mandatory | The status of the external RIM communication bus. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(… |
| 1.3.6.1.4.1.318.1.1.1.13.7 | NodeupsDiagnosticPowerCabinet | |||
| 1.3.6.1.4.1.318.1.1.1.13.7.1 | ScalarupsDiagnosticPowerCabinetTableSize | read-only | mandatory | The maximum number of Power Cabinets supported by the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.7.2 | TableupsDiagnosticPowerCabinetTable | not-accessible | mandatory | Allows for diagnostics of individual Power Cabinets. The number of entries is contained in the upsDiagnosticPowerCabinetTableSize OID. |
| 1.3.6.1.4.1.318.1.1.1.13.7.2.1 | RowupsDiagnosticPowerCabinetEntry | not-accessible | mandatory | The diagnostics of a Power Cabinet. |
| 1.3.6.1.4.1.318.1.1.1.13.7.2.1.1 | ColumnupsDiagnosticPowerCabinetIndex | read-only | mandatory | The index to the Power Cabinet. |
| 1.3.6.1.4.1.318.1.1.1.13.7.2.1.2 | ColumnupsDiagnosticPowerCabinetAmbientTemperature | read-only | mandatory | The ambient temperature of Power Cabinet in tenths of degrees Celsius. If the Power Cabinet is not present, this variable is set to (-1). |
| 1.3.6.1.4.1.318.1.1.1.13.8 | NodeupsDiagnosticDisplay | |||
| 1.3.6.1.4.1.318.1.1.1.13.8.1 | ScalarupsDiagnosticDisplayHardwareRev | read-only | mandatory | The hardware revision of the Display. |
| 1.3.6.1.4.1.318.1.1.1.13.8.2 | ScalarupsDiagnosticDisplaySerialNum | read-only | mandatory | The serial number of the Display. |
| 1.3.6.1.4.1.318.1.1.1.13.8.3 | ScalarupsDiagnosticDisplayFirmwareRev | read-only | mandatory | The firmware revision of the Display. |
| 1.3.6.1.4.1.318.1.1.1.13.8.4 | ScalarupsDiagnosticDisplayModelNum | read-only | mandatory | The model number of the Display. |
| 1.3.6.1.4.1.318.1.1.1.13.8.5 | ScalarupsDiagnosticDisplayStatus | read-only | mandatory | The System Level Controller Status. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicate… |
| 1.3.6.1.4.1.318.1.1.1.13.9 | NodeupsDiagnosticUnitController | |||
| 1.3.6.1.4.1.318.1.1.1.13.9.1 | ScalarupsDiagUnitControllerTableSize | read-only | mandatory | The number of Unit Controllers in or attached to the UPS. |
| 1.3.6.1.4.1.318.1.1.1.13.9.2 | TableupsDiagUnitControllerTable | not-accessible | mandatory | Allows for diagnostics of individual Intelligence Modules. The number of entries is contained in the upsDiagUnitControllerTableSize OID. |
| 1.3.6.1.4.1.318.1.1.1.13.9.2.1 | RowupsDiagUnitControllerEntry | not-accessible | mandatory | The diagnostics and information of an Intelligence Module. |
| 1.3.6.1.4.1.318.1.1.1.13.9.2.1.1 | ColumnupsDiagUnitControllerIndex | read-only | mandatory | The index to the Unit Controller entry. |
| 1.3.6.1.4.1.318.1.1.1.13.9.2.1.2 | ColumnupsDiagUnitControllerStatus | read-only | mandatory | The status of the Unit Controller. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates… |
| 1.3.6.1.4.1.318.1.1.1.13.9.2.1.3 | ColumnupsDiagUnitControllerFirmwareRev | read-only | mandatory | The firmware revision of the Unit Controller. |
| 1.3.6.1.4.1.318.1.1.1.13.9.2.1.4 | ColumnupsDiagUnitControllerHardwareRev | read-only | mandatory | The hardware revision of the Unit Controller. |
| 1.3.6.1.4.1.318.1.1.1.13.9.2.1.5 | ColumnupsDiagUnitControllerSerialNum | read-only | mandatory | The serial number of the Unit Controller. |
| 1.3.6.1.4.1.318.1.1.1.13.9.2.1.6 | ColumnupsDiagUnitControllerModelNum | read-only | mandatory | The model number of the Unit Controller. |
| 1.3.6.1.4.1.318.1.1.1.13.10 | NodeupsDiagnosticSLC | |||
| 1.3.6.1.4.1.318.1.1.1.13.10.1 | ScalarupsDiagnosticSLCHardwareRev | read-only | mandatory | The hardware revision of the System Level Controller. |
| 1.3.6.1.4.1.318.1.1.1.13.10.2 | ScalarupsDiagnosticSLCSerialNum | read-only | mandatory | The serial number of the System Level Controller. |
| 1.3.6.1.4.1.318.1.1.1.13.10.3 | ScalarupsDiagnosticSLCFirmwareRev | read-only | mandatory | The firmware revision of the System Level Controller. |
| 1.3.6.1.4.1.318.1.1.1.13.10.4 | ScalarupsDiagnosticSLCModelNumber | read-only | mandatory | The Model number of the System Level Controller. |
| 1.3.6.1.4.1.318.1.1.1.13.10.5 | ScalarupsDiagSLCStatus | read-only | mandatory | The System Level Controller Status. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicate… |
| 1.3.6.1.4.1.318.1.1.1.14 | NodeupsParallelSystem | |||
| 1.3.6.1.4.1.318.1.1.1.14.1 | ScalarupsParallelSysLocalAddress | read-write | mandatory | Defines the UPS ID number in the parallel system. |
| 1.3.6.1.4.1.318.1.1.1.14.2 | ScalarupsParallelSysRemoteAddress | read-write | mandatory | Defines the total number of UPSs in parallel. |
| 1.3.6.1.4.1.318.1.1.1.14.3 | ScalarupsParallelSysRedundancy | read-write | mandatory | The redundancy warning level for paralleled UPS nplus0 (1) indicates that there are no redundant units. nplus1 (2) indicates that there is one redundant unit. … |
| 1.3.6.1.4.1.318.1.1.1.14.4 | ScalarupsParallelInputMaximumCurrent | read-only | mandatory | Maximum input RMS current of the parallel system measured in Amperes. |
| 1.3.6.1.4.1.318.1.1.1.14.5 | ScalarupsParallelTotalOutputPower | read-only | mandatory | The Total Ouptut power of UPS in KW when UPS are configured in parallel or -1 if it's unsupported by this UPS. |
| 1.3.6.1.4.1.318.1.1.1.14.6 | ScalarupsParallelTotalOutputApparentPower | read-only | mandatory | The Total Ouptut Apparent power of UPS in kVA when UPS are configured in parallel or -1 if it's unsupported by this UPS. |
| 1.3.6.1.4.1.318.1.1.1.14.7 | TableupsParallelInputPhaseTable | not-accessible | mandatory | A list of input table entries. |
| 1.3.6.1.4.1.318.1.1.1.14.7.1 | RowupsParallelInputPhaseEntry | not-accessible | mandatory | An entry containing information applicable to a particular input phase. |
| 1.3.6.1.4.1.318.1.1.1.14.7.1.1 | ColumnupsParallelInputPhaseTableIndex | read-only | mandatory | The parallel unit identifier. |
| 1.3.6.1.4.1.318.1.1.1.14.7.1.2 | ColumnupsParallelInputPhaseIndex | read-only | mandatory | The input phase identifier. |
| 1.3.6.1.4.1.318.1.1.1.14.7.1.3 | ColumnupsParallelInputCurrent | read-only | mandatory | The input current in amperes, or -1 if it's unsupported by this UPS. |
| 1.3.6.1.4.1.318.1.1.1.14.7.1.4 | ColumnupsParallelInputActivePower | read-only | mandatory | The input power in kW, or -1 if it's unsupported by this UPS. |
| 1.3.6.1.4.1.318.1.1.1.14.7.1.5 | ColumnupsParallelInputApparentPower | read-only | mandatory | The input apparent power in kVA, or -1 if it's unsupported by this UPS. |
| 1.3.6.1.4.1.318.1.1.1.14.7.1.6 | ColumnupsParallelInputVoltage | read-only | mandatory | The input voltage of UPS in volts, or -1 if it's unsupported by this UPS. |
| 1.3.6.1.4.1.318.1.1.1.14.7.1.7 | ColumnupsParallelInputMaxVoltage | read-only | mandatory | The peak input voltage in VAC measured since the last reset, or -1 if it's unsupported by this UPS. |
| 1.3.6.1.4.1.318.1.1.1.14.7.1.8 | ColumnupsParallelInputMaxCurrent | read-only | mandatory | The peak input current in amperes measured since last reset, or -1 if it's unsupported by this UPS. |
| 1.3.6.1.4.1.318.1.1.1.14.7.1.9 | ColumnupsParallelInputTotalActivePower | read-only | mandatory | Total active input power of the parallel system in kW. |
| 1.3.6.1.4.1.318.1.1.1.14.7.1.10 | ColumnupsParallelInputTotalApparentPower | read-only | mandatory | Total apparent input power of the parallel system in kVA. |
| 1.3.6.1.4.1.318.1.1.1.14.8 | TableupsParallelOutputPhaseTable | not-accessible | mandatory | A list of output table entries. The number of entries is given by the sum of the upsPhaseNumOutputPhases. |
| 1.3.6.1.4.1.318.1.1.1.14.8.1 | RowupsParallelOutputPhaseEntry | not-accessible | mandatory | An entry containing information applicable to a particular output phase. |
| 1.3.6.1.4.1.318.1.1.1.14.8.1.1 | ColumnupsParallelOutputPhaseTableIndex | read-only | mandatory | The output identifier. |
| 1.3.6.1.4.1.318.1.1.1.14.8.1.2 | ColumnupsParallelOutputPhaseIndex | read-only | mandatory | The output phase identifier. |
| 1.3.6.1.4.1.318.1.1.1.14.8.1.3 | ColumnupsParallelOutputCurrent | read-only | mandatory | The output current in amperes drawn by the load on the UPS, or -1 if it's unsupported by this UPS. |
| 1.3.6.1.4.1.318.1.1.1.14.8.1.4 | ColumnupsParallelOutputLoad | read-only | mandatory | The output load in VA, or -1 if it's unsupported by this UPS. |
| 1.3.6.1.4.1.318.1.1.1.14.8.1.5 | ColumnupsParallelOutputPercentLoad | read-only | mandatory | The percentage of the UPS load capacity in VA at present redundancy being used on this output phase, or -1 if it's unsupported by this UPS. |
| 1.3.6.1.4.1.318.1.1.1.14.8.1.6 | ColumnupsParallelOutputPower | read-only | mandatory | The output power in Watts, or -1 if it's unsupported by this UPS. |
| 1.3.6.1.4.1.318.1.1.1.14.9 | TableupsParallelOutputApparentPowerTable | not-accessible | mandatory | A list of output table entries. The number of entries is given by the value of upsOutputNumPhases. |
| 1.3.6.1.4.1.318.1.1.1.14.9.1 | RowupsParallelOutputApparentPowerEntry | not-accessible | mandatory | An entry containing information applicable to a particular output. |
| 1.3.6.1.4.1.318.1.1.1.14.9.1.1 | ColumnupsParallelOutputApparentPowerTableIndex | read-only | mandatory | The UPS parallel output identifier. |
| 1.3.6.1.4.1.318.1.1.1.14.9.1.2 | ColumnupsParallelOutputApparentPower | read-only | mandatory | The apparent power of each of UPS in kVA when UPS are configured in parallel. |
| 1.3.6.1.4.1.318.1.1.1.14.10 | TableupsParallelDiagSubSysBreakerTable | not-accessible | mandatory | Allows for diagnostics of parallel Circuit Breakers. |
| 1.3.6.1.4.1.318.1.1.1.14.10.1 | RowupsParallelDiagSubSysBreakerEntry | not-accessible | mandatory | The diagnostics of Circuit Breaker. |
| 1.3.6.1.4.1.318.1.1.1.14.10.1.1 | ColumnupsParallelDiagSubSysBreakerFrameIndex | read-only | mandatory | The Parallel UPS index entry. |
| 1.3.6.1.4.1.318.1.1.1.14.10.1.2 | ColumnupsParallelDiagSubSysBreakerIndex | read-only | mandatory | The index of the Circuit Breaker. |
| 1.3.6.1.4.1.318.1.1.1.14.10.1.3 | ColumnupsParallelDiagSubSysBreakerStatus | read-only | mandatory | The status of the Circuit Breaker. unknown(1) indicates the circuit breaker status is unknown. notInstalled(2) indicates the circuit breaker is not installed. … |
| 1.3.6.1.4.1.318.1.1.1.14.10.1.4 | ColumnupsParallelDiagSubSysBreakerName | read-only | mandatory | The name of Circuit Breaker. |
| 1.3.6.1.4.1.318.1.1.1.14.11 | ScalarupsParallelOutputTotalPercentLoad | read-only | mandatory | The percentage of the UPS total load capacity in kVA or -1 if it's unsupported by this UPS. |
| 1.3.6.1.4.1.318.1.1.1.14.12 | TableupsParallelOutputActivePowerTable | not-accessible | mandatory | A list of output table entries. The number of entries is given by the value of upsParallelSysRemoteAddress. |
| 1.3.6.1.4.1.318.1.1.1.14.12.1 | RowupsParallelOutputActivePowerEntry | not-accessible | mandatory | An entry containing information applicable to a particular output. |
| 1.3.6.1.4.1.318.1.1.1.14.12.1.1 | ColumnupsParallelOutputActivePowerTableIndex | read-only | mandatory | The UPS parallel output identifier. |
| 1.3.6.1.4.1.318.1.1.1.14.12.1.2 | ColumnupsParallelOutputActivePower | read-only | mandatory | The active power of each UPS in kW when UPSs are configured in parallel. |
| 1.3.6.1.4.1.318.1.1.1.14.13 | ScalarupsParallelSysSwitchGearInstallationLoadPct | read-only | mandatory | The actual output load expressed as a percentage of the rating of the Parallel UPS system. |
| 1.3.6.1.4.1.318.1.1.1.14.14 | ScalarupsParallelSysRedundancyStatus | read-only | mandatory | Displays the number of backup or redundant UPSs set up on the parallel system. nplus0 (1) no redundant units. nplus1 (2) one redundant unit. nplus2 (3) two red… |
| 1.3.6.1.4.1.318.1.1.1.14.15 | ScalarupsParallelSysName | read-write | mandatory | An ID string for the group of UPS units in the same parallel system. Some products do not allow write operations for this OID. |
| 1.3.6.1.4.1.318.1.1.1.14.16 | ScalarupsParallelSysUpsTableSize | read-only | mandatory | The number of UPSs in parallel. |
| 1.3.6.1.4.1.318.1.1.1.14.17 | TableupsParallelSysUpsTable | not-accessible | mandatory | A list of UPS table entries. The number of entries is given by the value of upsParallelSysUpsTableize. |
| 1.3.6.1.4.1.318.1.1.1.14.17.1 | RowupsParallelSysUpsEntry | not-accessible | mandatory | An entry containing information applicable to a particular UPS in parallel. |
| 1.3.6.1.4.1.318.1.1.1.14.17.1.1 | ColumnupsParallelSysUpsIndex | read-only | mandatory | The index to the Parallel System UPS table entry. |
| 1.3.6.1.4.1.318.1.1.1.14.17.1.2 | ColumnupsParallelSysUpsName | read-only | mandatory | The UPS id as assigned by the system. |
| 1.3.6.1.4.1.318.1.1.1.14.17.1.3 | ColumnupsParallelSysUpsAlarmStatus | read-only | mandatory | The alarm status of the UPS. unknown(1) indicates the UPS status is unknown. normal(2) indicates UPS is functioning normally. informational(3) indicates inform… |
| 1.3.6.1.4.1.318.1.1.1.14.17.1.4 | ColumnupsParallelSysUpsMode | read-only | mandatory | The current operating mode of the UPS. If the UPS is unable to determine the state of the UPS, this variable is set to unknown(1). |
| 1.3.6.1.4.1.318.1.1.1.14.18 | ScalarupsParallelNumOfUpsPoweringLoad | read-only | mandatory | Number of UPS powered and protecting the load which are not defective (no battery fault, no internal fault). |
| 1.3.6.1.4.1.318.1.1.1.14.19 | ScalarupsParallelMinNumOfRequiredUps | read-only | mandatory | Minimal number of UPS required to guarantee the availability of power. |
| 1.3.6.1.4.1.318.1.1.1.15 | NodeupsPhysicalLayout | |||
| 1.3.6.1.4.1.318.1.1.1.15.1 | ScalarupsIOFrameLayoutPositionID | read-only | mandatory | Defines the position ID of UPS frame. |
| 1.3.6.1.4.1.318.1.1.1.15.2 | ScalarupsBottomFeedFrameLayoutPositionID | read-only | mandatory | Defines the position ID of bottom feed frame. |
| 1.3.6.1.4.1.318.1.1.1.15.3 | ScalarupsSwitchGearLayoutPositionID | read-only | mandatory | Defines the position ID of switchgear. |
| 1.3.6.1.4.1.318.1.1.1.15.4 | ScalarupsBatteryFrameLayoutTableSize | read-only | mandatory | The number of battery frames. |
| 1.3.6.1.4.1.318.1.1.1.15.5 | TableupsBatteryFrameLayoutTable | not-accessible | mandatory | Battery frame layout position ID table. |
| 1.3.6.1.4.1.318.1.1.1.15.5.1 | RowupsBatteryFrameLayoutEntry | not-accessible | mandatory | A list of layout position IDs of battery frames. |
| 1.3.6.1.4.1.318.1.1.1.15.5.1.1 | ColumnbatteryFrameIndex | read-only | mandatory | The index of the battery frame. |
| 1.3.6.1.4.1.318.1.1.1.15.5.1.2 | ColumnbatteryFramePositionID | read-only | mandatory | Defines the position ID of each of the battery frames in the row. |
| 1.3.6.1.4.1.318.1.1.1.15.6 | ScalarupsSideCarFrameLayoutTableSize | read-only | mandatory | The number of sidecar frames. |
| 1.3.6.1.4.1.318.1.1.1.15.7 | TableupsSideCarFrameLayoutTable | not-accessible | mandatory | Sidecar frame layout position ID table. |
| 1.3.6.1.4.1.318.1.1.1.15.7.1 | RowupsSideCarFrameLayoutEntry | not-accessible | mandatory | A list of sidecar frame layout position IDs. |
| 1.3.6.1.4.1.318.1.1.1.15.7.1.1 | ColumnsideCarFrameIndex | read-only | mandatory | The index of the sidecar frame. |
| 1.3.6.1.4.1.318.1.1.1.15.7.1.2 | ColumnsideCarFramePositionID | read-only | mandatory | Defines the position ID of each of the sidecar frames in the row. |
| 1.3.6.1.4.1.318.1.1.1.15.8 | ScalarupsPowerFrameLayoutTableSize | read-only | mandatory | The number of power frames. |
| 1.3.6.1.4.1.318.1.1.1.15.9 | TableupsPowerFrameLayoutTable | not-accessible | mandatory | Power frame layout position ID table. |
| 1.3.6.1.4.1.318.1.1.1.15.9.1 | RowupsPowerFrameLayoutEntry | not-accessible | mandatory | A list of power frame layout position IDs. |
| 1.3.6.1.4.1.318.1.1.1.15.9.1.1 | ColumnpowerFrameIndex | read-only | mandatory | The index of the power frame. |
| 1.3.6.1.4.1.318.1.1.1.15.9.1.2 | ColumnpowerFramePositionID | read-only | mandatory | Defines the position ID of each of the power frames in the row. |
| 1.3.6.1.4.1.318.1.1.1.16 | NodeupsIntegratedATS | |||
| 1.3.6.1.4.1.318.1.1.1.16.1 | ScalarupsIntegratedATSSelectedSource | read-only | mandatory | The source which is currently selected by the ATS to supply the UPS. |
| 1.3.6.1.4.1.318.1.1.1.16.2 | ScalarupsIntegratedATSPreferredSource | read-write | mandatory | The preferred source of power when both sources are OK. |
| 1.3.6.1.4.1.318.1.1.1.16.3 | ScalarupsIntegratedATSUpsReturnStaggering | read-write | mandatory | This is a delay factor applied to the retransfer of this UPS with integrated ATS. When multiple UPSs are in use from a single source, each UPS can have a uniqu… |
| 1.3.6.1.4.1.318.1.1.1.16.4 | ScalarupsIntegratedATSSourceTableSize | read-only | mandatory | The number of input sources for this integrated ATS. |
| 1.3.6.1.4.1.318.1.1.1.16.5 | TableupsIntegratedATSSourceTable | not-accessible | mandatory | Allows for getting status and settings for the ATS input sources. The number of entries is contained in the upsIntegratedATSSourceTableSize OID. |
| 1.3.6.1.4.1.318.1.1.1.16.5.1 | RowupsIntegratedATSSourceEntry | not-accessible | mandatory | The input source status to get. |
| 1.3.6.1.4.1.318.1.1.1.16.5.1.1 | ColumnupsIntegratedATSSourceIndex | read-only | mandatory | The index to the input source entry. |
| 1.3.6.1.4.1.318.1.1.1.16.5.1.2 | ColumnupsIntegratedATSSourceName | read-only | mandatory | The name of the input source. This OID is provided for informational purposes only. |
| 1.3.6.1.4.1.318.1.1.1.16.5.1.3 | ColumnupsIntegratedATSSourceStatus | read-only | mandatory | Getting this variable will return the input source status. |
| 1.3.6.1.4.1.318.1.1.1.16.5.1.4 | ColumnupsIntegratedATSLineFailDelay | read-write | mandatory | The delay between a selected input source becoming bad, and the ATS switching away from that source. This delay is used to make sure that the line has truly fa… |
| 1.3.6.1.4.1.318.1.1.1.16.5.1.5 | ColumnupsIntegratedATSLineStabilityDelay | read-write | mandatory | The delay between an unselected input source becoming good, and the ATS switching to that source. This delay is used to make sure that the line has truly retur… |
| 1.3.6.1.4.1.318.1.1.1.17 | NodeupsDCOutput | |||
| 1.3.6.1.4.1.318.1.1.1.17.1 | NodeupsDCOutputStatus | |||
| 1.3.6.1.4.1.318.1.1.1.17.1.1 | ScalarupsDCOutputStatusTableSize | read-only | mandatory | The number of DC outputs on the UPS. |
| 1.3.6.1.4.1.318.1.1.1.17.1.2 | TableupsDCOutputStatusTable | not-accessible | mandatory | Provides status information on UPS DC outputs. The number of entries is contained in the upsDCOutputStatusTableSize OID. |
| 1.3.6.1.4.1.318.1.1.1.17.1.2.1 | RowupsDCOutputStatusEntry | not-accessible | mandatory | The DC output. |
| 1.3.6.1.4.1.318.1.1.1.17.1.2.1.1 | ColumnupsDCOutputStatusTableIndex | read-only | mandatory | The index to the DC output status entry. |
| 1.3.6.1.4.1.318.1.1.1.17.1.2.1.2 | ColumnupsDCOutputStatusVoltageNominal | read-only | mandatory | The desired voltage for this output in tenths of VDC. When the output is on and there are no fault conditions, the actual voltage should be near the nominal. |
| 1.3.6.1.4.1.318.1.1.1.17.1.2.1.3 | ColumnupsDCOutputStatusCurrentRating | read-only | mandatory | The amount of current this output is able to supply in tenths of amperes. |
| 1.3.6.1.4.1.318.1.1.1.17.1.2.1.4 | ColumnupsDCOutputStatusVoltage | read-only | mandatory | The voltage measured on this output in tenths of VDC. |
| 1.3.6.1.4.1.318.1.1.1.17.1.2.1.5 | ColumnupsDCOutputStatusCurrent | read-only | mandatory | The current drawn by the load measured on this output in tenths of amperes. |
| 1.3.6.1.4.1.318.1.1.1.17.1.2.1.6 | ColumnupsDCOutputStatusAbnormalConditions | read-only | mandatory | An ASCII string containing flags representing active output faults. If the Network Card is unable to determine the state of the faults, this variable is set to… |
| 1.3.6.1.4.1.318.1.1.1.18 | NodeupsIntegratedUIO | |||
| 1.3.6.1.4.1.318.1.1.1.18.1 | NodeupsOutputRelays | |||
| 1.3.6.1.4.1.318.1.1.1.18.1.1 | ScalarupsOutputRelayStatusTableSize | read-only | mandatory | The number of integrated output relays on the UPS. |
| 1.3.6.1.4.1.318.1.1.1.18.1.2 | TableupsOutputRelayStatusTable | not-accessible | mandatory | Allows for access of individual relays. |
| 1.3.6.1.4.1.318.1.1.1.18.1.2.1 | RowupsOutputRelayStatusEntry | not-accessible | mandatory | The output relays to access. |
| 1.3.6.1.4.1.318.1.1.1.18.1.2.1.1 | ColumnupsOutputRelayIndex | read-only | mandatory | The index to the output relay entry. |
| 1.3.6.1.4.1.318.1.1.1.18.1.2.1.2 | ColumnupsOutputRelayState | read-only | mandatory | Getting this variable will return the output relay state. 1 - normal state 2 - abnormal state |
| 1.3.6.1.4.1.318.1.1.1.20 | NodeupsEnergyEfficiency | |||
| 1.3.6.1.4.1.318.1.1.1.20.1 | NodeupsECOmode | |||
| 1.3.6.1.4.1.318.1.1.1.20.1.1 | ScalarupsEcoModeFreqTransferRange | read-only | mandatory | Indicates tolerance of bypass AC frequency in Hz to switch on ECO mode. |
| 1.3.6.1.4.1.318.1.1.1.20.1.2 | ScalarupsEcoModeHighVoltThreshold | read-only | mandatory | Indicates high threshold on AC voltage in volts to switch on ECO mode. |
| 1.3.6.1.4.1.318.1.1.1.20.1.3 | ScalarupsEcoModeLowVoltThreshold | read-only | mandatory | Indicates low threshold on AC voltage in volts to switch on ECO mode. |
| 1.3.6.1.4.1.318.1.1.1.20.1.4 | ScalarupsEcoModeSetting | read-only | mandatory | Indicates whether ECO feature is avaiable to this UPS or not. |
| 1.3.6.1.4.1.318.1.1.1.20.1.5 | ScalarupsEcoModeStatus | read-only | mandatory | Indicates whether UPS is running in ECO mode or not. |
| 1.3.6.1.4.1.318.1.1.1.20.1.6 | ScalarupsEcoModeCountSinceReset | read-only | mandatory | Number of times UPS entered into ECO mode since maintenance reset. |
| 1.3.6.1.4.1.318.1.1.1.20.1.7 | ScalarupsEcoModeOnlineSinceCommission | read-only | mandatory | Total runtime in online mode with ECO feature enabled once product is authorized to use (in minutes). |
| 1.3.6.1.4.1.318.1.1.1.20.1.8 | ScalarupsEcoModeOnlineSinceReset | read-only | mandatory | Total runtime in online mode with ECO feature enabled since maintenance reset (in minutes). |
| 1.3.6.1.4.1.318.1.1.1.20.1.9 | ScalarupsEcoModeTotalPercentTimeSinceReset | read-only | mandatory | Indicates percentage of runtime in ECO mode since maintenance reset. |
| 1.3.6.1.4.1.318.1.1.1.20.1.10 | ScalarupsEcoModePercentTimeSinceCommission | read-only | mandatory | Indicates percentage of operation time in ECO mode once product is authorized to use. |
| 1.3.6.1.4.1.318.1.1.1.20.1.11 | ScalarupsEcoModeTotalTimeSinceReset | read-only | mandatory | Total runtime of UPS in ECO mode since maintenance reset (in minutes). |
| 1.3.6.1.4.1.318.1.1.1.20.1.12 | ScalarupsEcoModeTotalTimeSinceCommission | read-only | mandatory | Total runtime in ECO mode once product is authorized to use (in minutes). |
| 1.3.6.1.4.1.318.1.1.1.20.1.13 | ScalarupsEcoModeTotalTimeInMonth | read-only | mandatory | Total runtime of UPS in ECO mode since beginning of month (in minutes). |
| 1.3.6.1.4.1.318.1.1.1.20.2 | NodeupsEBMmode | |||
| 1.3.6.1.4.1.318.1.1.1.20.2.1 | ScalarupsEbmModeSetting | read-only | mandatory | Indicates whether efficiency booster mode feature is avaiable to this UPS or not. |
| 1.3.6.1.4.1.318.1.1.1.20.2.2 | ScalarupsEbmModeStatus | read-only | mandatory | Indicates whether UPS is running on EBM mode or not. |
| 1.3.6.1.4.1.318.1.1.1.20.2.3 | ScalarupsEbmModeCountSinceReset | read-only | mandatory | Number of times UPS entered into efficiency booster mode since maintenance reset. |
| 1.3.6.1.4.1.318.1.1.1.20.2.4 | ScalarupsEbmModeTotalTimeInMonth | read-only | mandatory | Total runtime of UPS in efficiency booster mode since beginning of month (in minutes). |
| 1.3.6.1.4.1.318.1.1.1.20.2.5 | ScalarupsEbmModeTotalTimeSinceReset | read-only | mandatory | Total runtime of UPS in efficiency booster mode since maintenance reset (in minutes). |
| 1.3.6.1.4.1.318.1.1.1.20.2.6 | ScalarupsEbmModeTotalPercentTimeSinceReset | read-only | mandatory | Indicates percentage of runtime in efficiency booster mode since maintenance reset. |
| 1.3.6.1.4.1.318.1.1.1.20.2.7 | ScalarupsEbmModeOnlineSinceCommission | read-only | mandatory | Indicates runtime in online mode with EBM feature enabled once product is authorized to use (in minutes). |
| 1.3.6.1.4.1.318.1.1.1.20.2.8 | ScalarupsEbmModePercentTimeSinceCommission | read-only | mandatory | Indicates percentage of operation time in efficiency booster mode once product is authorized to use. |
| 1.3.6.1.4.1.318.1.1.1.20.2.9 | ScalarupsEbmModeRuntimeSinceCommission | read-only | mandatory | Total runtime in efficiency booster mode once product is authorized to use (in minutes). |
| 1.3.6.1.4.1.318.1.1.1.20.2.10 | ScalarupsEbmModeOnlineSinceReset | read-only | mandatory | Total runtime in online mode with EBM feature enabled since maintenance reset (in minutes). |
| 1.3.6.1.4.1.318.1.1.1.20.2.11 | ScalarupsEbmModeUpsCount | read-only | mandatory | Number of UPS's running in efficiency booster mode. |
| 1.3.6.1.4.1.318.1.1.2 | NodemeasureUps | |||
| 1.3.6.1.4.1.318.1.1.2.1 | NodemUpsEnviron | |||
| 1.3.6.1.4.1.318.1.1.2.1.1 | ScalarmUpsEnvironAmbientTemperature | read-only | mandatory | The ambient temperature in Celsius for Probe 1. |
| 1.3.6.1.4.1.318.1.1.2.1.2 | ScalarmUpsEnvironRelativeHumidity | read-only | mandatory | The relative humidity as a percentage for Probe 1. |
| 1.3.6.1.4.1.318.1.1.2.1.3 | ScalarmUpsEnvironAmbientTemperature2 | read-only | mandatory | The ambient temperature in Celsius for Probe 2. |
| 1.3.6.1.4.1.318.1.1.2.1.4 | ScalarmUpsEnvironRelativeHumidity2 | read-only | mandatory | The relative humidity as a percentage for Probe 2. |
| 1.3.6.1.4.1.318.1.1.2.2 | NodemUpsContact | |||
| 1.3.6.1.4.1.318.1.1.2.2.1 | ScalarmUpsContactNumContacts | read-only | mandatory | The number of contacts supported by the Measure-UPS. |
| 1.3.6.1.4.1.318.1.1.2.2.2 | TablemUpsContactTable | not-accessible | mandatory | A list of contacts supported by the Measure-UPS. |
| 1.3.6.1.4.1.318.1.1.2.2.2.1 | RowmUpsContactEntry | not-accessible | mandatory | A contact entry containing information for a given contact. |
| 1.3.6.1.4.1.318.1.1.2.2.2.1.1 | ColumncontactNumber | read-only | mandatory | An index identifying the contact on the Measure-UPS. |
| 1.3.6.1.4.1.318.1.1.2.2.2.1.2 | ColumnnormalState | read-write | mandatory | The normal operating position of the contact. If the normal operating position cannot be set then it is controlled via the dip switch on the Measure-UPS and is… |
| 1.3.6.1.4.1.318.1.1.2.2.2.1.3 | Columndescription | read-write | mandatory | The description of the purpose/use of the contact. |
| 1.3.6.1.4.1.318.1.1.2.2.2.1.4 | ColumnmonitoringStatus | read-write | mandatory | A flag indicating whether this contact is monitored, or not. |
| 1.3.6.1.4.1.318.1.1.2.2.2.1.5 | ColumncurrentStatus | read-only | mandatory | This value indicates the current state of the contact. If the contact is not in its normal state. This value is set to fault(2). |
| 1.3.6.1.4.1.318.1.1.3 | NodeminiSNMPadapter | |||
| 1.3.6.1.4.1.318.1.1.3.1 | NodeserialPort | |||
| 1.3.6.1.4.1.318.1.1.3.1.1 | NodeserialPort1 | |||
| 1.3.6.1.4.1.318.1.1.3.1.2 | NodeserialPort2 | |||
| 1.3.6.1.4.1.318.1.1.3.1.2.1 | NodeserialPort2Config | |||
| 1.3.6.1.4.1.318.1.1.3.1.2.1.1 | ScalarserialPort2Mode | read-write | obsolete | Setting this variable to passthrough will enable mini's port2 behave like a UPS port. Choosing localConsole will enable the port to be used as local console. |
| 1.3.6.1.4.1.318.1.1.3.1.2.2 | NodeserialPort2Control | |||
| 1.3.6.1.4.1.318.1.1.3.1.2.2.1 | ScalarsetPulseOnTXD | read-write | obsolete | Setting this variable to setPulseOnTXD(2) causes adapter to generate a PULSE on TXD pin of serial port 2. The duration in the prototype implementation will be … |
| 1.3.6.1.4.1.318.1.1.4 | Nodemasterswitch | |||
| 1.3.6.1.4.1.318.1.1.4.1 | NodesPDUIdent | |||
| 1.3.6.1.4.1.318.1.1.4.1.1 | ScalarsPDUIdentHardwareRev | read-only | mandatory | The hardware revision of the PDU. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.4.1.2 | ScalarsPDUIdentFirmwareRev | read-only | mandatory | An 8 byte ID string identifying the PDU firmware revision. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.4.1.3 | ScalarsPDUIdentDateOfManufacture | read-only | mandatory | The date when the PDU was manufactured in mm/dd/yy format. This value is set at the factory. The year 2000 will be represented by 00. |
| 1.3.6.1.4.1.318.1.1.4.1.4 | ScalarsPDUIdentModelNumber | read-only | mandatory | A 10-character string identifying the model number of the PDU internal. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.4.1.5 | ScalarsPDUIdentSerialNumber | read-only | mandatory | A 12-character string identifying the serial number of the PDU internal microprocessor. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.4.2 | NodesPDUMasterControl | |||
| 1.3.6.1.4.1.318.1.1.4.2.1 | ScalarsPDUMasterControlSwitch | read-write | mandatory | Setting this OID to turnAllOnNow (1) will turn all outlets on immediately. Setting this OID to turnAllOnSequence (2) will turn all outlets on as defined by eac… |
| 1.3.6.1.4.1.318.1.1.4.2.2 | ScalarsPDUMasterState | read-only | mandatory | Getting this OID will cause the status of all outlets to be returned. This OID is provided for informational purposes only. To change the outlet state, the use… |
| 1.3.6.1.4.1.318.1.1.4.2.3 | ScalarsPDUMasterPending | read-only | mandatory | Getting this OID will cause the command pending status of all outlets to be returned. The format of the data returned is a character string consisting of the w… |
| 1.3.6.1.4.1.318.1.1.4.3 | NodesPDUMasterConfig | |||
| 1.3.6.1.4.1.318.1.1.4.3.1 | ScalarsPDUMasterConfigPowerOn | read-write | mandatory | The amount of delay, in seconds, between when power is provided to the PDU and when the PDU provides basic master power to the outlets. Allowed values are: -1 … |
| 1.3.6.1.4.1.318.1.1.4.3.2 | ScalarsPDUMasterConfigReboot | read-write | mandatory | During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait, in seconds, after turning the power off, at the st… |
| 1.3.6.1.4.1.318.1.1.4.3.3 | ScalarsPDUMasterConfigPDUName | read-write | mandatory | The name of the PDU. |
| 1.3.6.1.4.1.318.1.1.4.4 | NodesPDUOutletControl | |||
| 1.3.6.1.4.1.318.1.1.4.4.1 | ScalarsPDUOutletControlTableSize | read-only | mandatory | The number of outlets for the PDU. |
| 1.3.6.1.4.1.318.1.1.4.4.2 | TablesPDUOutletControlTable | not-accessible | mandatory | Allows for control of individual outlet switches. The number of entries is contained in the sPDUOutletControlTableSize OID. |
| 1.3.6.1.4.1.318.1.1.4.4.2.1 | RowsPDUOutletControlEntry | not-accessible | mandatory | The outlets to control. |
| 1.3.6.1.4.1.318.1.1.4.4.2.1.1 | ColumnsPDUOutletControlIndex | read-only | mandatory | The index to the outlet entry. |
| 1.3.6.1.4.1.318.1.1.4.4.2.1.2 | ColumnsPDUOutletPending | read-only | mandatory | Reports whether the current outlet has a pending command. If the commandPendingUnknown (3) value is returned, all devices powered by the PDU should be shut dow… |
| 1.3.6.1.4.1.318.1.1.4.4.2.1.3 | ColumnsPDUOutletCtl | read-write | mandatory | Getting this variable will return the outlet state. If the outlet is on, the outletOn (1) value will be returned. If the outlet is off, the outletOff (2) value… |
| 1.3.6.1.4.1.318.1.1.4.4.2.1.4 | ColumnsPDUOutletCtlName | read-only | mandatory | The name of the outlet. Maximum size is 20 characters. This OID is provided for informational purposes only. This value is set by the sPDUOutletName OID. |
| 1.3.6.1.4.1.318.1.1.4.5 | NodesPDUOutletConfig | |||
| 1.3.6.1.4.1.318.1.1.4.5.1 | ScalarsPDUOutletConfigTableSize | read-only | mandatory | The number of outlets for the PDU. |
| 1.3.6.1.4.1.318.1.1.4.5.2 | TablesPDUOutletConfigTable | not-accessible | mandatory | The list of outlets to configure. The number of entries is defined by the sPDUOutletConfigTableSize OID. |
| 1.3.6.1.4.1.318.1.1.4.5.2.1 | RowsPDUOutletConfigEntry | not-accessible | mandatory | The outlets to control. |
| 1.3.6.1.4.1.318.1.1.4.5.2.1.1 | ColumnsPDUOutletConfigIndex | read-only | mandatory | The index to the outlet entry. |
| 1.3.6.1.4.1.318.1.1.4.5.2.1.2 | ColumnsPDUOutletPowerOnTime | read-write | mandatory | The amount of time (in seconds) the outlet will delay powering on when the MasterSwitch is powered on. Allowed values are: -1 never power on automatically. 0 p… |
| 1.3.6.1.4.1.318.1.1.4.5.2.1.3 | ColumnsPDUOutletName | read-write | mandatory | The name of the outlet. Maximum size is 20 characters. |
| 1.3.6.1.4.1.318.1.1.4.5.2.1.4 | ColumnsPDUOutletPowerOffTime | read-write | mandatory | The amount of time (in seconds) the outlet will delay powering off. Allowed values are: -1 never power off automatically. 0 power off with the MasterSwitch. 15… |
| 1.3.6.1.4.1.318.1.1.4.5.2.1.5 | ColumnsPDUOutletRebootDuration | read-write | mandatory | During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait, in seconds, after turning the power off, at the st… |
| 1.3.6.1.4.1.318.1.1.5 | NodemasterswitchVM | |||
| 1.3.6.1.4.1.318.1.1.5.1 | NodesPDUIdentVM | |||
| 1.3.6.1.4.1.318.1.1.5.1.1 | ScalarsPDUIdentVMTableSize | read-only | mandatory | The number of MasterSwitch VMs controllable by this IP address. |
| 1.3.6.1.4.1.318.1.1.5.1.2 | TablesPDUIdentVMTable | not-accessible | mandatory | Allows for query of the individual MasterSwitch VMs. The number of entries is contained in the sPDUIdentVMTableSize OID. |
| 1.3.6.1.4.1.318.1.1.5.1.2.1 | RowsPDUIdentVMEntry | not-accessible | mandatory | The MasterSwitch VMs to query. |
| 1.3.6.1.4.1.318.1.1.5.1.2.1.1 | ColumnsPDUIdentVMIndex | read-only | mandatory | The index to the MasterSwitch VM entry. |
| 1.3.6.1.4.1.318.1.1.5.1.2.1.2 | ColumnsPDUIdentNameVM | read-only | mandatory | A 23-character string identifying the MasterSwitch VM. |
| 1.3.6.1.4.1.318.1.1.5.1.2.1.3 | ColumnsPDUIdentHardwareRevVM | read-only | mandatory | The hardware version of the MasterSwitch VM. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.5.1.2.1.4 | ColumnsPDUIdentFirmwareRevVM | read-only | mandatory | An 6-character ID string identifying the MasterSwitch VM firmware version. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.5.1.2.1.5 | ColumnsPDUIdentDateOfManufactureVM | read-only | mandatory | The date when the MasterSwitch VM was manufactured in mm/dd/yyyy format. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.5.1.2.1.6 | ColumnsPDUIdentModelNumberVM | read-only | mandatory | A 17-character string identifying the model number of the MasterSwitch VM. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.5.1.2.1.7 | ColumnsPDUIdentSerialNumberVM | read-only | mandatory | A 17-character string identifying the serial number of the MasterSwitch VM. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.5.2 | NodesPDUMasterControlVM | |||
| 1.3.6.1.4.1.318.1.1.5.2.1 | ScalarsPDUMasterControlVMTableSize | read-only | mandatory | The number of MasterSwitch VMs controllable by this IP address. |
| 1.3.6.1.4.1.318.1.1.5.2.2 | TablesPDUMasterControlVMTable | not-accessible | mandatory | Allows for control of the individual MasterSwitch VMs. The number of entries is contained in the sPDUMasterControlVMTableSize OID. |
| 1.3.6.1.4.1.318.1.1.5.2.2.1 | RowsPDUMasterControlVMEntry | not-accessible | mandatory | The MasterSwitch VMs to control. |
| 1.3.6.1.4.1.318.1.1.5.2.2.1.1 | ColumnsPDUMasterControlVMIndex | read-only | mandatory | The index to the MasterSwitch VM entry. |
| 1.3.6.1.4.1.318.1.1.5.2.2.1.2 | ColumnsPDUMasterControlVMName | read-only | mandatory | The name of the MasterSwitch VM. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigVMName OID. |
| 1.3.6.1.4.1.318.1.1.5.2.2.1.3 | ColumnsPDUMasterControlVMCommand | read-write | mandatory | Setting this OID to immediateAllOnVM (2) will turn all outlets on immediately. Setting this OID to immediateAllOffVM (3) will turn all outlets off immediately.… |
| 1.3.6.1.4.1.318.1.1.5.3 | NodesPDUMasterConfigVM | |||
| 1.3.6.1.4.1.318.1.1.5.3.1 | ScalarsPDUMasterConfigVMTableSize | read-only | mandatory | The number of MasterSwitch VMs configurable by this IP address. |
| 1.3.6.1.4.1.318.1.1.5.3.2 | TablesPDUMasterConfigVMTable | not-accessible | mandatory | Allows for configuration of the individual MasterSwitch VMs. The number of entries is contained in the sPDUMasterConfigVMTableSize OID. |
| 1.3.6.1.4.1.318.1.1.5.3.2.1 | RowsPDUMasterConfigVMEntry | not-accessible | mandatory | The MasterSwitch VMs to configure. |
| 1.3.6.1.4.1.318.1.1.5.3.2.1.1 | ColumnsPDUMasterConfigVMIndex | read-only | mandatory | The index to the MasterSwitch VM entry. |
| 1.3.6.1.4.1.318.1.1.5.3.2.1.2 | ColumnsPDUMasterConfigVMName | read-write | mandatory | The name of the MasterSwitch VM. Maximum size is 23 characters. |
| 1.3.6.1.4.1.318.1.1.5.3.2.1.3 | ColumnsPDUMasterConfigVMColdstartDelay | read-write | mandatory | The amount of delay, in seconds, between when power is provided to the MasterSwitch VM and when the MasterSwitch VM provides basic master power to the outlets.… |
| 1.3.6.1.4.1.318.1.1.5.3.2.1.4 | ColumnsPDUMasterConfigVMAudioAlarmActivated | read-write | mandatory | Setting this OID to audioAlarmActiveNever (1) will disable the audio alarm on the MasterSwitch VM. Setting this OID to audioAlarmActiveOnOverload (2) will acti… |
| 1.3.6.1.4.1.318.1.1.5.3.2.1.5 | ColumnsPDUMasterConfigVMHighLoadWarningThreshold | read-write | mandatory | A threshold that indicates the power consumption of the load is nearing an overload condition. It is represented as a percentage of full load. |
| 1.3.6.1.4.1.318.1.1.5.3.2.1.6 | ColumnsPDUMasterConfigVMLowLoadWarningThreshold | read-write | mandatory | A threshold that indicates the power consumption of the load is nearing a low consumption condition. It is represented as a percentage of full load. |
| 1.3.6.1.4.1.318.1.1.5.3.2.1.7 | ColumnsPDUMasterConfigVMOverloadRestriction | read-write | mandatory | This OID controls the behavior of the MasterSwitch VM when an overload condition is possible and additional outlets are requested to be turned on. Setting this… |
| 1.3.6.1.4.1.318.1.1.5.4 | NodesPDUMasterStatusVM | |||
| 1.3.6.1.4.1.318.1.1.5.4.1 | ScalarsPDUMasterStatusVMTableSize | read-only | mandatory | The number of MasterSwitch VMs at this IP address. |
| 1.3.6.1.4.1.318.1.1.5.4.2 | TablesPDUMasterStatusVMTable | not-accessible | mandatory | Allows for gathering of status from the individual MasterSwitch VMs. The number of entries is contained in the sPDUMasterStatusVMTableSize OID. |
| 1.3.6.1.4.1.318.1.1.5.4.2.1 | RowsPDUMasterStatusVMEntry | not-accessible | mandatory | The MasterSwitch VMs to gather status from. |
| 1.3.6.1.4.1.318.1.1.5.4.2.1.1 | ColumnsPDUMasterStatusVMIndex | read-only | mandatory | The index to the MasterSwitch VM entry. |
| 1.3.6.1.4.1.318.1.1.5.4.2.1.2 | ColumnsPDUMasterStatusVMName | read-only | mandatory | The name of the MasterSwitch VM. Maximum size is 23 characters. |
| 1.3.6.1.4.1.318.1.1.5.4.2.1.3 | ColumnsPDUMasterStatusVMCommandPending | read-only | mandatory | Getting this OID will return commandPendingMasterTrueVM (1) if the MasterSwitch VM has a pending command on any of its outlets. commandPendingMasterFalseVM (2)… |
| 1.3.6.1.4.1.318.1.1.5.4.2.1.4 | ColumnsPDUMasterStatusVMOverloadCondition | read-only | mandatory | Getting this OID will return overloadConditionTrueVM (1) if the sPDUMasterConfigVMHighLoadWarningThreshold OID is violated. overloadConditionFalseVM (2) will b… |
| 1.3.6.1.4.1.318.1.1.5.4.2.1.5 | ColumnsPDUMasterStatusVMLowLoadCondition | read-only | mandatory | Getting this OID will return lowLoadConditionTrueVM (1) if the sPDUMasterConfigVMLowLoadWarningThreshold OID is violated. lowLoadConditionFalseVM (2) will be r… |
| 1.3.6.1.4.1.318.1.1.5.4.2.1.6 | ColumnsPDUMasterStatusVMCurrentLoad | read-only | mandatory | Getting this OID will return the total amount of power being consumed by the load. It is represented as a percentage of full load. |
| 1.3.6.1.4.1.318.1.1.5.4.2.1.7 | ColumnsPDUMasterStatusVMMaxLoad | read-only | mandatory | Getting this OID will return the total amount of power that this MasterSwitch VM can provide. It is represented in Amps. |
| 1.3.6.1.4.1.318.1.1.5.4.2.1.8 | ColumnsPDUMasterStatusVMOutletCount | read-only | mandatory | Getting this OID will return the number of controllable outlets for this MasterSwitch VM. |
| 1.3.6.1.4.1.318.1.1.5.4.2.1.9 | ColumnsPDUMasterStatusVMRebootDuration | read-only | mandatory | Getting this OID will return the largest sPDUOutletConfigVMRebootDuration OID time for this MasterSwitch VM. |
| 1.3.6.1.4.1.318.1.1.5.5 | NodesPDUOutletControlVM | |||
| 1.3.6.1.4.1.318.1.1.5.5.1 | TablesPDUOutletControlVMTable | not-accessible | mandatory | Allows for control of individual outlet switches. The number of entries is contained in the sPDUMasterStatusOutletCount OID. |
| 1.3.6.1.4.1.318.1.1.5.5.1.1 | RowsPDUOutletControlVMEntry | not-accessible | mandatory | The outlets to control. |
| 1.3.6.1.4.1.318.1.1.5.5.1.1.1 | ColumnsPDUOutletControlVMIndex | read-only | mandatory | The index to the MasterSwitch VM. |
| 1.3.6.1.4.1.318.1.1.5.5.1.1.2 | ColumnsPDUOutletControlVMName | read-only | mandatory | The name of the MasterSwitch VM. Maximum size is 23 characters. This OID is provided for informational purposes only. |
| 1.3.6.1.4.1.318.1.1.5.5.1.1.3 | ColumnsPDUOutletControlVMOutletIndex | read-only | mandatory | The index to the outlet entry. |
| 1.3.6.1.4.1.318.1.1.5.5.1.1.4 | ColumnsPDUOutletControlVMOutletName | read-only | mandatory | The name of the outlet. Maximum size is 23 characters. This OID is provided for informational purposes only. |
| 1.3.6.1.4.1.318.1.1.5.5.1.1.5 | ColumnsPDUOutletControlVMOutletCommand | read-write | mandatory | Getting this variable will return the outlet state. If the outlet is on, the immediateOnVM (1) value will be returned. If the outlet is off, the immediateOffVM… |
| 1.3.6.1.4.1.318.1.1.5.6 | NodesPDUOutletConfigVM | |||
| 1.3.6.1.4.1.318.1.1.5.6.1 | TablesPDUOutletConfigVMTable | not-accessible | mandatory | Allows for configuration of individual outlets. The number of entries is contained in the sPDUMasterStatusOutletCount OID. |
| 1.3.6.1.4.1.318.1.1.5.6.1.1 | RowsPDUOutletConfigVMEntry | not-accessible | mandatory | The outlets to configure. |
| 1.3.6.1.4.1.318.1.1.5.6.1.1.1 | ColumnsPDUOutletConfigVMIndex | read-only | mandatory | The index to the MasterSwitch VM. |
| 1.3.6.1.4.1.318.1.1.5.6.1.1.2 | ColumnsPDUOutletConfigVMName | read-only | mandatory | The name of the MasterSwitch VM. Maximum size is 23 characters. |
| 1.3.6.1.4.1.318.1.1.5.6.1.1.3 | ColumnsPDUOutletConfigVMOutletIndex | read-only | mandatory | The index to the outlet entry. |
| 1.3.6.1.4.1.318.1.1.5.6.1.1.4 | ColumnsPDUOutletConfigVMOutletName | read-write | mandatory | The name of the outlet. Maximum size is 23 characters. |
| 1.3.6.1.4.1.318.1.1.5.6.1.1.5 | ColumnsPDUOutletConfigVMPowerOnTime | read-write | mandatory | The amount of time (in seconds) the outlet will delay powering on at coldstart or when a command that requires a turn-on delay is issued. Allowed values are: -… |
| 1.3.6.1.4.1.318.1.1.5.6.1.1.6 | ColumnsPDUOutletConfigVMPowerOffTime | read-write | mandatory | The amount of time (in seconds) the outlet will delay powering off when a command that requires a turn-off delay is issued. Allowed values are: -1 never power … |
| 1.3.6.1.4.1.318.1.1.5.6.1.1.7 | ColumnsPDUOutletConfigVMRebootDuration | read-write | mandatory | During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait, in seconds, after turning the power off, at the st… |
| 1.3.6.1.4.1.318.1.1.5.7 | NodesPDUOutletStatusVM | |||
| 1.3.6.1.4.1.318.1.1.5.7.1 | TablesPDUOutletStatusVMTable | not-accessible | mandatory | Allows for getting of status of individual outlets. The number of entries is contained in the sPDUMasterStatusOutletCount OID. |
| 1.3.6.1.4.1.318.1.1.5.7.1.1 | RowsPDUOutletStatusVMEntry | not-accessible | mandatory | The outlets to gather status from. |
| 1.3.6.1.4.1.318.1.1.5.7.1.1.1 | ColumnsPDUOutletStatusVMIndex | read-only | mandatory | The index to the MasterSwitch VM. |
| 1.3.6.1.4.1.318.1.1.5.7.1.1.2 | ColumnsPDUOutletStatusVMName | read-only | mandatory | The name of the MasterSwitch VM. Maximum size is 23 characters. |
| 1.3.6.1.4.1.318.1.1.5.7.1.1.3 | ColumnsPDUOutletStatusVMOutletIndex | read-only | mandatory | The index to the outlet entry. |
| 1.3.6.1.4.1.318.1.1.5.7.1.1.4 | ColumnsPDUOutletStatusVMOutletName | read-only | mandatory | The name of the outlet. Maximum size is 23 characters. |
| 1.3.6.1.4.1.318.1.1.5.7.1.1.5 | ColumnsPDUOutletStatusVMOutletState | read-only | mandatory | Getting this variable will return the outlet state. If the outlet is on, the outletStatusOnVM (1) value will be returned. If the outlet is off, the outletStatu… |
| 1.3.6.1.4.1.318.1.1.5.7.1.1.6 | ColumnsPDUOutletStatusVMCommandPending | read-only | mandatory | Getting this variable will return the command pending state of the outlet. If a command is pending on the outlet, the outletStatusVMCommandPending (1) value wi… |
| 1.3.6.1.4.1.318.1.1.6 | NodemasterswitchMSP | |||
| 1.3.6.1.4.1.318.1.1.6.1 | NodesPDUIdentMSP | |||
| 1.3.6.1.4.1.318.1.1.6.1.1 | ScalarsPDUIdentMSPTableSize | read-only | mandatory | The number of MasterSwitch pluses controllable by this IP address. |
| 1.3.6.1.4.1.318.1.1.6.1.2 | TablesPDUIdentMSPTable | not-accessible | mandatory | Allows for query of the individual MasterSwitch pluses. The number of entries is contained in the sPDUIdentMSPTableSize OID. |
| 1.3.6.1.4.1.318.1.1.6.1.2.1 | RowsPDUIdentMSPEntry | not-accessible | mandatory | The MasterSwitch pluses to query. |
| 1.3.6.1.4.1.318.1.1.6.1.2.1.1 | ColumnsPDUIdentMSPIndex | read-only | mandatory | The index to the MasterSwitch plus entry. |
| 1.3.6.1.4.1.318.1.1.6.1.2.1.2 | ColumnsPDUIdentNameMSP | read-only | mandatory | The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID. |
| 1.3.6.1.4.1.318.1.1.6.1.2.1.3 | ColumnsPDUIdentHardwareRevMSP | read-only | mandatory | The hardware version of the MasterSwitch plus. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.6.1.2.1.4 | ColumnsPDUIdentFirmwareRevMSP | read-only | mandatory | An 6-character ID string identifying the MasterSwitch plus firmware version. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.6.1.2.1.5 | ColumnsPDUIdentDateOfManufactureMSP | read-only | mandatory | The date when the MasterSwitch plus was manufactured in mm/dd/yyyy format. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.6.1.2.1.6 | ColumnsPDUIdentModelNumberMSP | read-only | mandatory | A 17-character string identifying the model number of the MasterSwitch plus. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.6.1.2.1.7 | ColumnsPDUIdentSerialNumberMSP | read-only | mandatory | A 17-character string identifying the serial number of the MasterSwitch plus. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.6.2 | NodesPDUMasterControlMSP | |||
| 1.3.6.1.4.1.318.1.1.6.2.1 | ScalarsPDUMasterControlMSPTableSize | read-only | mandatory | The number of MasterSwitch pluses controllable by this IP address. |
| 1.3.6.1.4.1.318.1.1.6.2.2 | TablesPDUMasterControlMSPTable | not-accessible | mandatory | Allows for control of the individual MasterSwitch pluses. The number of entries is contained in the sPDUMasterControlMSPTableSize OID. |
| 1.3.6.1.4.1.318.1.1.6.2.2.1 | RowsPDUMasterControlMSPEntry | not-accessible | mandatory | The MasterSwitch pluses to control. |
| 1.3.6.1.4.1.318.1.1.6.2.2.1.1 | ColumnsPDUMasterControlMSPIndex | read-only | mandatory | The index to the MasterSwitch plus entry. |
| 1.3.6.1.4.1.318.1.1.6.2.2.1.2 | ColumnsPDUMasterControlMSPName | read-only | mandatory | The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID. |
| 1.3.6.1.4.1.318.1.1.6.2.2.1.3 | ColumnsPDUMasterControlMSPCommand | read-write | mandatory | Setting this OID to immediateAllOnMSP (2) will turn all outlets on immediately. Setting this OID to sequencedAllOnMSP (3) will turn all outlets on as defined b… |
| 1.3.6.1.4.1.318.1.1.6.3 | NodesPDUMasterConfigMSP | |||
| 1.3.6.1.4.1.318.1.1.6.3.1 | ScalarsPDUMasterConfigMSPTableSize | read-only | mandatory | The number of MasterSwitch pluses configurable by this IP address. |
| 1.3.6.1.4.1.318.1.1.6.3.2 | TablesPDUMasterConfigMSPTable | not-accessible | mandatory | Allows for configuration of the individual MasterSwitch pluses. The number of entries is contained in the sPDUMasterConfigMSPTableSize OID. |
| 1.3.6.1.4.1.318.1.1.6.3.2.1 | RowsPDUMasterConfigMSPEntry | not-accessible | mandatory | The MasterSwitch pluses to configure. |
| 1.3.6.1.4.1.318.1.1.6.3.2.1.1 | ColumnsPDUMasterConfigMSPIndex | read-only | mandatory | The index to the MasterSwitch plus entry. |
| 1.3.6.1.4.1.318.1.1.6.3.2.1.2 | ColumnsPDUMasterConfigMSPName | read-write | mandatory | The name of the MasterSwitch plus. Maximum size is 23 characters. |
| 1.3.6.1.4.1.318.1.1.6.3.2.1.3 | ColumnsPDUMasterConfigMSPPowerOnTimeDelay | read-write | mandatory | The amount of delay, in seconds, between when power is provided to the MasterSwitch plus and when the MasterSwitch plus provides basic master power to the outl… |
| 1.3.6.1.4.1.318.1.1.6.3.2.1.4 | ColumnsPDUMasterConfigMSPManualButton | read-write | mandatory | Setting this OID to manualButtonDisabled (1) will disable the manual button on the MasterSwitch plus. Setting this OID to manualButtonEnabled (2) will enable t… |
| 1.3.6.1.4.1.318.1.1.6.4 | NodesPDUMasterStatusMSP | |||
| 1.3.6.1.4.1.318.1.1.6.4.1 | ScalarsPDUMasterStatusMSPTableSize | read-only | mandatory | The number of MasterSwitch pluses at this IP address. |
| 1.3.6.1.4.1.318.1.1.6.4.2 | TablesPDUMasterStatusMSPTable | not-accessible | mandatory | Allows for gathering of status from the individual MasterSwitch pluses. The number of entries is contained in the sPDUMasterStatusMSPTableSize OID. |
| 1.3.6.1.4.1.318.1.1.6.4.2.1 | RowsPDUMasterStatusMSPEntry | not-accessible | mandatory | The MasterSwitch pluses to gather status from. |
| 1.3.6.1.4.1.318.1.1.6.4.2.1.1 | ColumnsPDUMasterStatusMSPIndex | read-only | mandatory | The index to the MasterSwitch plus entry. |
| 1.3.6.1.4.1.318.1.1.6.4.2.1.2 | ColumnsPDUMasterStatusMSPName | read-only | mandatory | The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID. |
| 1.3.6.1.4.1.318.1.1.6.4.2.1.3 | ColumnsPDUMasterStatusMSPOutletCount | read-only | mandatory | Getting this OID will return the number of controllable outlets for this MasterSwitch plus. |
| 1.3.6.1.4.1.318.1.1.6.5 | NodesPDUOutletControlMSP | |||
| 1.3.6.1.4.1.318.1.1.6.5.1 | TablesPDUOutletControlMSPTable | not-accessible | mandatory | Allows for control of individual outlet switches. The number of entries is contained in the sPDUMasterStatusMSPOutletCount OID. |
| 1.3.6.1.4.1.318.1.1.6.5.1.1 | RowsPDUOutletControlMSPEntry | not-accessible | mandatory | The outlets to control. |
| 1.3.6.1.4.1.318.1.1.6.5.1.1.1 | ColumnsPDUOutletControlMSPIndex | read-only | mandatory | The index to the MasterSwitch plus. |
| 1.3.6.1.4.1.318.1.1.6.5.1.1.2 | ColumnsPDUOutletControlMSPName | read-only | mandatory | The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID. |
| 1.3.6.1.4.1.318.1.1.6.5.1.1.3 | ColumnsPDUOutletControlMSPOutletIndex | read-only | mandatory | The index to the outlet entry. |
| 1.3.6.1.4.1.318.1.1.6.5.1.1.4 | ColumnsPDUOutletControlMSPOutletName | read-only | mandatory | The name of the outlet. The maximum size is 23 characters. The name is set by using the sPDUOutletConfigMSPallOutletName OID. This OID is provided for informat… |
| 1.3.6.1.4.1.318.1.1.6.5.1.1.5 | ColumnsPDUOutletControlMSPOutletCommand | read-write | mandatory | Getting this variable will return the outlet state. If the outlet is on, the immediateOnMSP (1) value will be returned. If the outlet is off, the immediateOffM… |
| 1.3.6.1.4.1.318.1.1.6.6 | NodesPDUOutletConfigMSP | |||
| 1.3.6.1.4.1.318.1.1.6.6.1 | NodesPDUOutletConfigMSPall | |||
| 1.3.6.1.4.1.318.1.1.6.6.1.1 | TablesPDUOutletConfigMSPallTable | not-accessible | mandatory | Allows for configuration of individual outlets. The number of entries is contained in the sPDUMasterStatusMSPOutletCount OID. |
| 1.3.6.1.4.1.318.1.1.6.6.1.1.1 | RowsPDUOutletConfigMSPallEntry | not-accessible | mandatory | The outlets to configure. |
| 1.3.6.1.4.1.318.1.1.6.6.1.1.1.1 | ColumnsPDUOutletConfigMSPallIndex | read-only | mandatory | The index to the MasterSwitch plus. |
| 1.3.6.1.4.1.318.1.1.6.6.1.1.1.2 | ColumnsPDUOutletConfigMSPallName | read-only | mandatory | The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID. |
| 1.3.6.1.4.1.318.1.1.6.6.1.1.1.3 | ColumnsPDUOutletConfigMSPallOutletIndex | read-only | mandatory | The index to the outlet entry. |
| 1.3.6.1.4.1.318.1.1.6.6.1.1.1.4 | ColumnsPDUOutletConfigMSPallOutletName | read-write | mandatory | The name of the outlet. Maximum size is 23 characters. |
| 1.3.6.1.4.1.318.1.1.6.6.1.1.1.5 | ColumnsPDUOutletConfigMSPallOutletCtrlMode | read-write | mandatory | Setting this OID to modeGracefulShutdown (1) will put this outlet into the Graceful Shutdown control mode. Setting this OID to modeAnnunciator (2) will put thi… |
| 1.3.6.1.4.1.318.1.1.6.6.2 | NodesPDUOutletConfigMSPgs | |||
| 1.3.6.1.4.1.318.1.1.6.6.2.1 | TablesPDUOutletConfigMSPgsTable | not-accessible | mandatory | Allows for configuration of individual outlets. The number of entries is contained in the sPDUMasterStatusMSPOutletCount OID. |
| 1.3.6.1.4.1.318.1.1.6.6.2.1.1 | RowsPDUOutletConfigMSPgsEntry | not-accessible | mandatory | The outlets to configure. |
| 1.3.6.1.4.1.318.1.1.6.6.2.1.1.1 | ColumnsPDUOutletConfigMSPgsIndex | read-only | mandatory | The index to the MasterSwitch plus. |
| 1.3.6.1.4.1.318.1.1.6.6.2.1.1.2 | ColumnsPDUOutletConfigMSPgsName | read-only | mandatory | The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID. |
| 1.3.6.1.4.1.318.1.1.6.6.2.1.1.3 | ColumnsPDUOutletConfigMSPgsOutletIndex | read-only | mandatory | The index to the outlet entry. |
| 1.3.6.1.4.1.318.1.1.6.6.2.1.1.4 | ColumnsPDUOutletConfigMSPgsOutletName | read-only | mandatory | The name of the outlet. The maximum size is 23 characters. The name is set by using the sPDUOutletConfigMSPallOutletName OID. This OID is provided for informat… |
| 1.3.6.1.4.1.318.1.1.6.6.2.1.1.5 | ColumnsPDUOutletConfigMSPgsOutletCtrlMode | read-only | mandatory | The Control Mode of the outlet. This OID is provided for informational purposes only. |
| 1.3.6.1.4.1.318.1.1.6.6.2.1.1.6 | ColumnsPDUOutletConfigMSPgsDeviceConfirm | read-write | mandatory | Setting this OID to deviceConfirmNo (1) cause the outlet to NOT wait for device confirmation while performing graceful operations. Setting this OID to deviceCo… |
| 1.3.6.1.4.1.318.1.1.6.6.2.1.1.7 | ColumnsPDUOutletConfigMSPgsLowBattWarning | read-write | mandatory | The amount of delay, in 6 second intervals, between when the UPS goes on battery and the power down sequence for the outlet is initiated. Allowed values are: -… |
| 1.3.6.1.4.1.318.1.1.6.6.2.1.1.8 | ColumnsPDUOutletConfigMSPgsLowBattMult | read-write | mandatory | Only applicable if sPDUOutletConfigMSPgsLowBattWarning OID is set to -1 (On Runtime Remaining). Allows you to set the value to stagger the shutdown sequence of… |
| 1.3.6.1.4.1.318.1.1.6.6.2.1.1.9 | ColumnsPDUOutletConfigMSPgsRestartDelay | read-write | mandatory | The amount of delay, in 6 minute intervals, between when the outlet is turned off and the outlet is turned back on when performing a Graceful Shutdown. Allowed… |
| 1.3.6.1.4.1.318.1.1.6.6.2.1.1.10 | ColumnsPDUOutletConfigMSPgsPowerOnDelay | read-write | mandatory | The amount of delay, in seconds, between the UPS entering normal (on-line) state and the outlet being powered on. Allowed values are: -1 - Remain Off when the … |
| 1.3.6.1.4.1.318.1.1.6.6.2.1.1.11 | ColumnsPDUOutletConfigMSPgsPowerOffDelay | read-write | mandatory | The amount of delay, in seconds, between when the server shuts down and the outlet is powered off. Allowed values are: 0 - 9999 seconds (0 - 2 hrs, 46 mins, 39… |
| 1.3.6.1.4.1.318.1.1.6.6.2.1.1.12 | ColumnsPDUOutletConfigMSPgsBattCapThresh | read-write | mandatory | The minimum battery capacity, as a percent (0-100%), required of the UPS before an outlet will be allowed to power on. Allowed values are: 0 - 100 percent. |
| 1.3.6.1.4.1.318.1.1.6.6.2.1.1.13 | ColumnsPDUOutletConfigMSPgsRebootDuration | read-write | mandatory | The amount of delay, in seconds, from outlet off until outlet on during a reboot. Allowed values are: 0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs). |
| 1.3.6.1.4.1.318.1.1.6.6.3 | NodesPDUOutletConfigMSPannun | |||
| 1.3.6.1.4.1.318.1.1.6.6.3.1 | TablesPDUOutletConfigMSPannunTable | not-accessible | mandatory | Allows for configuration of individual outlets. The number of entries is contained in the sPDUMasterStatusMSPOutletCount OID. |
| 1.3.6.1.4.1.318.1.1.6.6.3.1.1 | RowsPDUOutletConfigMSPannunEntry | not-accessible | mandatory | The outlets to configure. |
| 1.3.6.1.4.1.318.1.1.6.6.3.1.1.1 | ColumnsPDUOutletConfigMSPannunIndex | read-only | mandatory | The index to the MasterSwitch plus. |
| 1.3.6.1.4.1.318.1.1.6.6.3.1.1.2 | ColumnsPDUOutletConfigMSPannunName | read-only | mandatory | The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID. |
| 1.3.6.1.4.1.318.1.1.6.6.3.1.1.3 | ColumnsPDUOutletConfigMSPannunOutletIndex | read-only | mandatory | The index to the outlet entry. |
| 1.3.6.1.4.1.318.1.1.6.6.3.1.1.4 | ColumnsPDUOutletConfigMSPannunOutletName | read-only | mandatory | The name of the outlet. The maximum size is 23 characters. The name is set by using the sPDUOutletConfigMSPallOutletName OID. This OID is provided for informat… |
| 1.3.6.1.4.1.318.1.1.6.6.3.1.1.5 | ColumnsPDUOutletConfigMSPannunOutletCtrlMode | read-only | mandatory | The Control Mode of the outlet. This OID is provided for informational purposes only. |
| 1.3.6.1.4.1.318.1.1.6.6.3.1.1.6 | ColumnsPDUOutletConfigMSPannunInitialState | read-write | mandatory | Setting this OID to initialStateOff (1) causes the outlet to default to off when in the non-alarmed condition. Setting this OID to initialStateOn (2) causes th… |
| 1.3.6.1.4.1.318.1.1.6.6.3.1.1.7 | ColumnsPDUOutletConfigMSPannunAlarmActionDly | read-write | mandatory | The amount of time, in seconds, that an enabled Measure-UPS alarm must be asserted before an alarm condition is recognized. Allowed values are: 0 - 9999 second… |
| 1.3.6.1.4.1.318.1.1.6.6.4 | NodesPDUOutletConfigMSPmups | |||
| 1.3.6.1.4.1.318.1.1.6.6.4.1 | TablesPDUOutletConfigMSPmupsTable | not-accessible | mandatory | Allows for configuration of individual outlets. The number of entries is contained in the sPDUMasterStatusMSPOutletCount OID. |
| 1.3.6.1.4.1.318.1.1.6.6.4.1.1 | RowsPDUOutletConfigMSPmupsEntry | not-accessible | mandatory | The outlets to configure. |
| 1.3.6.1.4.1.318.1.1.6.6.4.1.1.1 | ColumnsPDUOutletConfigMSPmupsIndex | read-only | mandatory | The index to the MasterSwitch plus. |
| 1.3.6.1.4.1.318.1.1.6.6.4.1.1.2 | ColumnsPDUOutletConfigMSPmupsName | read-only | mandatory | The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID. |
| 1.3.6.1.4.1.318.1.1.6.6.4.1.1.3 | ColumnsPDUOutletConfigMSPmupsOutletIndex | read-only | mandatory | The index to the outlet entry. |
| 1.3.6.1.4.1.318.1.1.6.6.4.1.1.4 | ColumnsPDUOutletConfigMSPmupsOutletName | read-only | mandatory | The name of the outlet. The maximum size is 23 characters. The name is set by using the sPDUOutletConfigMSPallOutletName OID. This OID is provided for informat… |
| 1.3.6.1.4.1.318.1.1.6.6.4.1.1.5 | ColumnsPDUOutletConfigMSPmupsZone1 | read-write | mandatory | Setting this OID to disableAlarm (1) disables the Zone 1 alarm for this outlet. Setting this OID to enableAlarm (2) enables the Zone 1 alarm for this outlet. |
| 1.3.6.1.4.1.318.1.1.6.6.4.1.1.6 | ColumnsPDUOutletConfigMSPmupsZone2 | read-write | mandatory | Setting this OID to disableAlarm (1) disables the Zone 2 alarm for this outlet. Setting this OID to enableAlarm (2) enables the Zone 2 alarm for this outlet. |
| 1.3.6.1.4.1.318.1.1.6.6.4.1.1.7 | ColumnsPDUOutletConfigMSPmupsZone3 | read-write | mandatory | Setting this OID to disableAlarm (1) disables the Zone 3 alarm for this outlet. Setting this OID to enableAlarm (2) enables the Zone 3 alarm for this outlet. |
| 1.3.6.1.4.1.318.1.1.6.6.4.1.1.8 | ColumnsPDUOutletConfigMSPmupsZone4 | read-write | mandatory | Setting this OID to disableAlarm (1) disables the Zone 4 alarm for this outlet. Setting this OID to enableAlarm (2) enables the Zone 4 alarm for this outlet. |
| 1.3.6.1.4.1.318.1.1.6.6.4.1.1.9 | ColumnsPDUOutletConfigMSPmupsP1LowHum | read-write | mandatory | Setting this OID to disableAlarm (1) disables the Probe 1 low humidity alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 1 low humid… |
| 1.3.6.1.4.1.318.1.1.6.6.4.1.1.10 | ColumnsPDUOutletConfigMSPmupsP1HiHum | read-write | mandatory | Setting this OID to disableAlarm (1) disables the Probe 1 high humidity alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 1 high hum… |
| 1.3.6.1.4.1.318.1.1.6.6.4.1.1.11 | ColumnsPDUOutletConfigMSPmupsP1LowTemp | read-write | mandatory | Setting this OID to disableAlarm (1) disables the Probe 1 low temperature alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 1 low te… |
| 1.3.6.1.4.1.318.1.1.6.6.4.1.1.12 | ColumnsPDUOutletConfigMSPmupsP1HiTemp | read-write | mandatory | Setting this OID to disableAlarm (1) disables the Probe 1 high temperature alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 1 high … |
| 1.3.6.1.4.1.318.1.1.6.6.4.1.1.13 | ColumnsPDUOutletConfigMSPmupsP2LowHum | read-write | mandatory | Setting this OID to disableAlarm (1) disables the Probe 2 low humidity alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 2 low humid… |
| 1.3.6.1.4.1.318.1.1.6.6.4.1.1.14 | ColumnsPDUOutletConfigMSPmupsP2HiHum | read-write | mandatory | Setting this OID to disableAlarm (1) disables the Probe 2 high humidity alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 2 high hum… |
| 1.3.6.1.4.1.318.1.1.6.6.4.1.1.15 | ColumnsPDUOutletConfigMSPmupsP2LowTemp | read-write | mandatory | Setting this OID to disableAlarm (1) disables the Probe 2 low temperature alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 2 low te… |
| 1.3.6.1.4.1.318.1.1.6.6.4.1.1.16 | ColumnsPDUOutletConfigMSPmupsP2HiTemp | read-write | mandatory | Setting this OID to disableAlarm (1) disables the Probe 2 high temperature alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 2 high … |
| 1.3.6.1.4.1.318.1.1.6.7 | NodesPDUOutletStatusMSP | |||
| 1.3.6.1.4.1.318.1.1.6.7.1 | TablesPDUOutletStatusMSPTable | not-accessible | mandatory | Allows for getting of status of individual outlets. The number of entries is contained in the sPDUMasterStatusOutletCount OID. |
| 1.3.6.1.4.1.318.1.1.6.7.1.1 | RowsPDUOutletStatusMSPEntry | not-accessible | mandatory | The outlets to gather status from. |
| 1.3.6.1.4.1.318.1.1.6.7.1.1.1 | ColumnsPDUOutletStatusMSPIndex | read-only | mandatory | The index to the MasterSwitch MSP. |
| 1.3.6.1.4.1.318.1.1.6.7.1.1.2 | ColumnsPDUOutletStatusMSPName | read-only | mandatory | The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID. |
| 1.3.6.1.4.1.318.1.1.6.7.1.1.3 | ColumnsPDUOutletStatusMSPOutletIndex | read-only | mandatory | The index to the outlet entry. |
| 1.3.6.1.4.1.318.1.1.6.7.1.1.4 | ColumnsPDUOutletStatusMSPOutletName | read-only | mandatory | The name of the outlet. The maximum size is 23 characters. The name is set by using the sPDUOutletConfigMSPallOutletName OID. This OID is provided for informat… |
| 1.3.6.1.4.1.318.1.1.6.7.1.1.5 | ColumnsPDUOutletStatusMSPOutletState | read-only | mandatory | Getting this variable will return the outlet state. If the outlet is on, the outletStatusMSPOn (1) value will be returned. If the outlet is off, the outletStat… |
| 1.3.6.1.4.1.318.1.1.6.7.1.1.6 | ColumnsPDUOutletStatusMSPCommandPending | read-only | mandatory | Getting this variable will return the command pending state of the outlet. If a command is pending on the outlet, the outletStatusMSPCommandPending (1) value w… |
| 1.3.6.1.4.1.318.1.1.6.7.1.1.7 | ColumnsPDUOutletStatusMSPOutletCtrlMode | read-only | mandatory | The Control Mode of the outlet. This OID is provided for informational purposes only. |
| 1.3.6.1.4.1.318.1.1.7 | NodedcDM3 | |||
| 1.3.6.1.4.1.318.1.1.7.1 | Nodedm3Ident | |||
| 1.3.6.1.4.1.318.1.1.7.1.1 | Nodedm3IdentSystem | |||
| 1.3.6.1.4.1.318.1.1.7.1.1.1 | Scalardm3IdentSysDescriptionTableSize | read-only | mandatory | The number of DC description records. |
| 1.3.6.1.4.1.318.1.1.7.1.1.2 | Tabledm3IdentSysDescriptionTable | not-accessible | mandatory | Allows for accessing description records of the powerplant. The number of entries is contained in the dm3IdentSysDescriptionTableSize OID. |
| 1.3.6.1.4.1.318.1.1.7.1.1.2.1 | Rowdm3IdentSysDescriptionEntry | not-accessible | mandatory | The powerplant description record to reference. |
| 1.3.6.1.4.1.318.1.1.7.1.1.2.1.1 | Columndm3IdentSysDescriptionIndex | read-only | mandatory | The index to the DC powerplant description record. |
| 1.3.6.1.4.1.318.1.1.7.1.1.2.1.2 | Columndm3IdentSysDescriptionText | read-only | mandatory | A 16 character text field describing the DC power plant device. This field can be configured from the dm3ConfigSysDescriptionText OID. |
| 1.3.6.1.4.1.318.1.1.7.1.1.3 | Scalardm3IdentSysModel | read-only | mandatory | Model type of the DC power plant. |
| 1.3.6.1.4.1.318.1.1.7.1.1.4 | Scalardm3IdentSysCntrlRev | read-only | mandatory | Integer representation of the hardware revision of the Master Controller board. |
| 1.3.6.1.4.1.318.1.1.7.1.1.5 | Scalardm3IdentSysFWVersion | read-only | mandatory | Integer representation of the power plant Master Controller firmware revision. |
| 1.3.6.1.4.1.318.1.1.7.2 | Nodedm3Config | |||
| 1.3.6.1.4.1.318.1.1.7.2.1 | Nodedm3ConfigSystem | |||
| 1.3.6.1.4.1.318.1.1.7.2.1.1 | Scalardm3ConfigSysDescriptionTableSize | read-only | mandatory | The number of DC description records. |
| 1.3.6.1.4.1.318.1.1.7.2.1.2 | Tabledm3ConfigSysDescriptionTable | not-accessible | mandatory | Allows for accessing description records of the powerplant. The number of entries is contained in the dm3ConfigSysDescriptionTableSize OID. |
| 1.3.6.1.4.1.318.1.1.7.2.1.2.1 | Rowdm3ConfigSysDescriptionEntry | not-accessible | mandatory | The powerplant description record to reference. |
| 1.3.6.1.4.1.318.1.1.7.2.1.2.1.1 | Columndm3ConfigSysDescriptionIndex | read-only | mandatory | The index to the DC powerplant description record. |
| 1.3.6.1.4.1.318.1.1.7.2.1.2.1.2 | Columndm3ConfigSysDescriptionText | read-write | mandatory | 16 character text field describing the DC power plant device. |
| 1.3.6.1.4.1.318.1.1.7.2.1.3 | Scalardm3ConfigSysHighTempThresh | read-write | mandatory | Ambient high temperature threshold. Temperature sensor located on Master Controller board. Values are represented in thousandths of a degree. Units are display… |
| 1.3.6.1.4.1.318.1.1.7.2.1.4 | Scalardm3ConfigSysHighTempAlarm | read-write | mandatory | For the System High Temperature Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) ca… |
| 1.3.6.1.4.1.318.1.1.7.2.1.5 | Scalardm3ConfigSysLowTempThresh | read-write | mandatory | Ambient low temperature threshold. Temperature sensor located on Master Controller board. Values are represented in thousandths of a degree. Units are displaye… |
| 1.3.6.1.4.1.318.1.1.7.2.1.6 | Scalardm3ConfigSysLowTempAlarm | read-write | mandatory | For the System Low Temperature Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) cau… |
| 1.3.6.1.4.1.318.1.1.7.2.1.7 | Scalardm3ConfigSysHardwareTempAlarm | read-write | mandatory | For the System Hardware Temperature Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2… |
| 1.3.6.1.4.1.318.1.1.7.2.1.8 | Scalardm3ConfigSysRemoteAccess | read-write | mandatory | This OID is used to disable remote write access to the power plant. Setting this OID to accessEnabled (1) will have no affect. Setting this OID to accessDisabl… |
| 1.3.6.1.4.1.318.1.1.7.2.2 | Nodedm3ConfigLVD | |||
| 1.3.6.1.4.1.318.1.1.7.2.2.1 | Scalardm3ConfigLVDTableSize | read-only | mandatory | The number of DC powerplant LVDs controllable by this IP address. |
| 1.3.6.1.4.1.318.1.1.7.2.2.2 | Tabledm3ConfigLVDTable | not-accessible | mandatory | Allows for accessing settings of the LVDs. The number of entries is contained in the dm3ConfigLVDTableSize OID. |
| 1.3.6.1.4.1.318.1.1.7.2.2.2.1 | Rowdm3ConfigLVDEntry | not-accessible | mandatory | The LVD to configure. |
| 1.3.6.1.4.1.318.1.1.7.2.2.2.1.1 | Columndm3ConfigLVDIndex | read-only | mandatory | The index to the DC powerplant LVD. |
| 1.3.6.1.4.1.318.1.1.7.2.2.2.1.2 | Columndm3ConfigLVDName | read-write | mandatory | The name of the LVD. The maximum value is 16 characters. |
| 1.3.6.1.4.1.318.1.1.7.2.2.2.1.3 | Columndm3ConfigLVDEnable | read-write | mandatory | This OID is used to control and indicate if the LVD is on or off. Setting this OID to enabledYes (1) will enable (turn on) the LVD. Setting this OID to enabled… |
| 1.3.6.1.4.1.318.1.1.7.2.2.2.1.4 | Columndm3ConfigLVDTripThresh | read-write | mandatory | LVD Trip threshold. If voltage exceeds threshold, the LVD will trip. Values are represented in thousandths of Volts (mV). Attempts to set the value above or be… |
| 1.3.6.1.4.1.318.1.1.7.2.2.2.1.5 | Columndm3ConfigLVDResetThresh | read-write | mandatory | LVD Reset threshold. If voltage exceeds threshold, the LVD will reset. Values are represented in thousandths of Volts (mV). Attempts to set the value above or … |
| 1.3.6.1.4.1.318.1.1.7.2.2.2.1.6 | Columndm3ConfigLVDOpenAlarm | read-write | mandatory | For the LVD Open Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to… |
| 1.3.6.1.4.1.318.1.1.7.2.2.2.1.7 | Columndm3ConfigLVDHWAlarm | read-write | mandatory | For the LVD Hardware Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay … |
| 1.3.6.1.4.1.318.1.1.7.2.3 | Nodedm3ConfigBattery | |||
| 1.3.6.1.4.1.318.1.1.7.2.3.1 | Scalardm3ConfigBattFloatVolt | read-write | mandatory | Battery Float Voltage. This setting controls the power plant voltage. Values are represented in thousandths of Volts (mV). Attempts to set the value above or b… |
| 1.3.6.1.4.1.318.1.1.7.2.3.2 | Scalardm3ConfigBattMaxRecharge | read-write | mandatory | Battery Maximum Recharge Rate. This setting controls the battery max recharge rate. The value is based on C/20 for 240 AHr battery string. Values are represent… |
| 1.3.6.1.4.1.318.1.1.7.2.3.3 | Scalardm3ConfigBattDischargeThresh | read-write | mandatory | Battery discharge threshold. If battery output current exceeds threshold a battery discharge alarm will occur. Values are represented in thousandths of Amps (m… |
| 1.3.6.1.4.1.318.1.1.7.2.3.4 | Scalardm3ConfigBattDischargeAlarm | read-write | mandatory | For the Battery Discharge Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes r… |
| 1.3.6.1.4.1.318.1.1.7.2.3.5 | Scalardm3ConfigBattHighVoltThresh | read-write | mandatory | Battery high voltage threshold. If system battery voltage exceeds threshold a battery high voltage alarm will occur. Values are represented in thousandths of V… |
| 1.3.6.1.4.1.318.1.1.7.2.3.6 | Scalardm3ConfigBattHighVoltAlarm | read-write | mandatory | For the Battery High Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) cause… |
| 1.3.6.1.4.1.318.1.1.7.2.3.7 | Scalardm3ConfigBattLowVoltThresh | read-write | mandatory | Battery low voltage threshold. If system battery voltage is under threshold a battery low voltage alarm will occur. Values are represented in thousandths of Vo… |
| 1.3.6.1.4.1.318.1.1.7.2.3.8 | Scalardm3ConfigBattLowVoltAlarm | read-write | mandatory | For the Battery Low Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes… |
| 1.3.6.1.4.1.318.1.1.7.2.3.9 | Scalardm3ConfigBattHighTempThresh | read-write | mandatory | Battery high temperature threshold. If system battery temperature exceeds threshold a battery high temperature alarm will occur. Values are represented in thou… |
| 1.3.6.1.4.1.318.1.1.7.2.3.10 | Scalardm3ConfigBattHighTempAlarm | read-write | mandatory | For the Battery High Temperature Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) c… |
| 1.3.6.1.4.1.318.1.1.7.2.3.11 | Scalardm3ConfigBattLowTempThresh | read-write | mandatory | Battery low temperature threshold. If system battery temperature is under threshold a battery low temperature alarm will occur. Values are represented in thous… |
| 1.3.6.1.4.1.318.1.1.7.2.3.12 | Scalardm3ConfigBattLowTempAlarm | read-write | mandatory | For the Battery Low Temperature Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) ca… |
| 1.3.6.1.4.1.318.1.1.7.2.3.13 | Scalardm3ConfigBattAmpHour | read-write | mandatory | Battery Amp-Hour Size. Units are thousandths of Amp hours (mAHr). Attempts to set the value above or below the acceptable range of the powerplant will cause th… |
| 1.3.6.1.4.1.318.1.1.7.2.3.14 | Scalardm3ConfigCompMethod | read-write | mandatory | This OID is used to configure and get the state of the battery temperature compensation. Setting this OID to tempcompOn (1) will enable/turn on the battery tem… |
| 1.3.6.1.4.1.318.1.1.7.2.3.15 | Scalardm3ConfigCompTempCoeff | read-write | mandatory | Compensation Temperature Coefficient. (uV/degC/cell). Units are presented in microvolts. Attempts to set the value above or below the acceptable range of the p… |
| 1.3.6.1.4.1.318.1.1.7.2.3.16 | Scalardm3ConfigHighKneeTemp | read-write | mandatory | High Knee for temperature compensation: Compensation temperature coefficient becomes 0mV/degC/cell. Values are represented in thousandths of degrees Celsius. A… |
| 1.3.6.1.4.1.318.1.1.7.2.3.17 | Scalardm3ConfigLowKneeTemp | read-write | mandatory | Low Knee for temperature compensation: Compensation temperature coefficient becomes 0mV/degC/cell. Values are represented in thousandths of degrees Celsius. At… |
| 1.3.6.1.4.1.318.1.1.7.2.3.18 | Scalardm3ConfigBattHwCurrentAlarm | read-write | mandatory | For the Battery Current Hardware Alarm (indicating current is outside realistic limits, or a possible measurement fault; Setting this OID to alarmIgnore (1) re… |
| 1.3.6.1.4.1.318.1.1.7.2.3.19 | Scalardm3ConfigBattHwTempAlarm | read-write | mandatory | For the Battery Temperature Hardware Alarm (indicating temperature is outside realistic limits, or a possible measurement fault; Setting this OID to alarmIgnor… |
| 1.3.6.1.4.1.318.1.1.7.2.4 | Nodedm3ConfigPowerModules | |||
| 1.3.6.1.4.1.318.1.1.7.2.4.1 | Nodedm3ConfigRectifier | |||
| 1.3.6.1.4.1.318.1.1.7.2.4.1.1 | Nodedm3ConfigRectThresh | |||
| 1.3.6.1.4.1.318.1.1.7.2.4.1.1.1 | Scalardm3ConfigRectHighVoltThresh | read-write | mandatory | Rectifier high voltage threshold. If rectifier voltage exceeds threshold a rectifier high voltage alarm will occur. Values are represented in thousandths of Vo… |
| 1.3.6.1.4.1.318.1.1.7.2.4.1.1.2 | Scalardm3ConfigRectLowVoltThresh | read-write | mandatory | Rectifier low voltage threshold. If rectifier voltage is under threshold a rectifier low voltage alarm will occur. Values are represented in thousandths of Vol… |
| 1.3.6.1.4.1.318.1.1.7.2.4.1.1.3 | Scalardm3ConfigRectFailSafe | read-write | mandatory | Rectifier Fail Safe point. This OID represents the value sent to rectifier controllers to use in the event of communications loss with the Master Controller or… |
| 1.3.6.1.4.1.318.1.1.7.2.4.1.1.4 | Scalardm3ConfigRectFailComm | read-write | mandatory | Rectifier Communication Fail timeout. This OID represents the time interval in which there is no communication between the rectifier and the master controller … |
| 1.3.6.1.4.1.318.1.1.7.2.4.1.2 | Nodedm3ConfigRectAlarms | |||
| 1.3.6.1.4.1.318.1.1.7.2.4.1.2.1 | Scalardm3ConfigRectHighVoltAlarm | read-write | mandatory | For the Rectifier High Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) cau… |
| 1.3.6.1.4.1.318.1.1.7.2.4.1.2.2 | Scalardm3ConfigRectLowVoltAlarm | read-write | mandatory | For the Rectifier Low Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) caus… |
| 1.3.6.1.4.1.318.1.1.7.2.4.1.2.3 | Scalardm3ConfigRectConfigAlarm | read-write | mandatory | This alarm is activated when a new rectifier is detected; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to… |
| 1.3.6.1.4.1.318.1.1.7.2.4.1.2.4 | Scalardm3ConfigRect1ofNAlarm | read-write | mandatory | This setting indicates the action if ONE rectifier of a N+1 system has failed; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored… |
| 1.3.6.1.4.1.318.1.1.7.2.4.1.2.5 | Scalardm3ConfigRect2ofNAlarm | read-write | mandatory | This setting indicates the action if TWO OR MORE rectifiers of a N+1 system have failed; Setting this OID to alarmIgnore (1) results in the alarm condition bei… |
| 1.3.6.1.4.1.318.1.1.7.2.4.1.2.6 | Scalardm3ConfigRectDiagAlarm | read-write | mandatory | For the Rectifier Controller Diagnostics Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRela… |
| 1.3.6.1.4.1.318.1.1.7.2.4.1.2.7 | Scalardm3ConfigRectImbalanceAlarm | read-write | mandatory | For the Rectifier Imbalance Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes… |
| 1.3.6.1.4.1.318.1.1.7.2.4.1.2.8 | Scalardm3ConfigRectCurrLimitAlarm | read-write | mandatory | For the Rectifier Current Limit Alarm (indicating rectifier in the Current Limit state); Setting this OID to alarmIgnore (1) results in the alarm condition bei… |
| 1.3.6.1.4.1.318.1.1.7.2.4.1.2.9 | Scalardm3ConfigRectStandbyAlarm | read-write | mandatory | For the Rectifier Standby Alarm (indicating output DC has been turned off); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. S… |
| 1.3.6.1.4.1.318.1.1.7.2.4.1.2.10 | Scalardm3ConfigRectFanFailAlarm | read-write | mandatory | For the Rectifier Fan Fail Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes … |
| 1.3.6.1.4.1.318.1.1.7.2.4.1.2.11 | Scalardm3ConfigRectFailAlarm | read-write | mandatory | For the Rectifier Fail Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes rela… |
| 1.3.6.1.4.1.318.1.1.7.2.4.1.2.12 | Scalardm3ConfigRectHwVoltAlarm | read-write | mandatory | For the Rectifier Hardware Voltage Alarm (indicating voltage outside realistic limits, or a possible measurement fault); Setting this OID to alarmIgnore (1) re… |
| 1.3.6.1.4.1.318.1.1.7.2.4.2 | Nodedm3ConfigConverter | |||
| 1.3.6.1.4.1.318.1.1.7.2.4.2.1 | Nodedm3ConfigConvThresh | |||
| 1.3.6.1.4.1.318.1.1.7.2.4.2.1.1 | Scalardm3ConfigConvHighVoltThresh | read-write | mandatory | Converter high voltage threshold. If converter voltage exceeds threshold a converter high voltage alarm will occur. Values are represented in thousandths of Vo… |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.1.2 | Scalardm3ConfigConvLowVoltThresh | read-write | mandatory | Converter low voltage threshold. If converter voltage exceeds threshold a converter low voltage alarm will occur. Values are represented in thousandths of Volt… |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.1.3 | Scalardm3ConfigConvFailSafe | read-write | mandatory | Converter Fail Safe point. This OID represents the value sent to converter controllers to use in the event of communications loss with the Master Controller or… |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.1.4 | Scalardm3ConfigConvSetPoint | read-write | mandatory | Converter Set point. This OID represents the initial set point used in the voltage control loop. Units are thousandths of Volts (mV). Attempts to set the value… |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.1.5 | Scalardm3ConfigConvFailMax | read-write | mandatory | Converter Fail Maximum limit. This OID represents the value sent to the converter controllers to define the maximum set point allowed. Units are thousandths of… |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.1.6 | Scalardm3ConfigConvFailMin | read-write | mandatory | Converter Fail Minimum limit. This OID represents the value sent to the converter controllers to define the minimum set point allowed. Units are thousandths of… |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.1.7 | Scalardm3ConfigConvFailComm | read-write | mandatory | Converter Communication Fail timeout. This OID represents the time interval in which there is no communication between the converter and the master controller … |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.2 | Nodedm3ConfigConvAlarms | |||
| 1.3.6.1.4.1.318.1.1.7.2.4.2.2.1 | Scalardm3ConfigConvHighVoltAlarm | read-write | mandatory | For the Converter High Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) cau… |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.2.2 | Scalardm3ConfigConvLowVoltAlarm | read-write | mandatory | For the Converter Low Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) caus… |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.2.3 | Scalardm3ConfigConvConfigAlarm | read-write | mandatory | For the Converter Configuration Alarm (indicating a new converter has been detected); Setting this OID to alarmIgnore (1) results in the alarm condition being … |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.2.4 | Scalardm3ConfigConv1ofNAlarm | read-write | mandatory | For the Converter 1ofN Alarm (indicating action if ONE converter of a N+1 system has failed); Setting this OID to alarmIgnore (1) results in the alarm conditio… |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.2.5 | Scalardm3ConfigConv2ofNAlarm | read-write | mandatory | For the Converter 2ofN Alarm (indicating action if TWO OR MORE converters of a N+1 system has failed); Setting this OID to alarmIgnore (1) results in the alarm… |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.2.6 | Scalardm3ConfigConvDiagAlarm | read-write | mandatory | For the Converter Diagnostics Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) caus… |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.2.7 | Scalardm3ConfigConvImbalanceAlarm | read-write | mandatory | For the Converter Imbalance Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes… |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.2.8 | Scalardm3ConfigConvCurrLimitAlarm | read-write | mandatory | For the Converter Current Limit Alarm (indicating the converter is in the Current Limit state); Setting this OID to alarmIgnore (1) results in the alarm condit… |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.2.9 | Scalardm3ConfigConvStandbyAlarm | read-write | mandatory | For the Converter Standby Alarm (indicating the converter is in the Standby state); Setting this OID to alarmIgnore (1) results in the alarm condition being ig… |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.2.10 | Scalardm3ConfigConvFanFailAlarm | read-write | mandatory | For the Converter Fan Fail Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes … |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.2.11 | Scalardm3ConfigConvFailAlarm | read-write | mandatory | For the Converter Fail Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes rela… |
| 1.3.6.1.4.1.318.1.1.7.2.4.2.2.12 | Scalardm3ConfigConvHwVoltAlarm | read-write | mandatory | For the Converter Voltage Alarm (indicating voltage outside realistic limits, or a possible measurement fault); Setting this OID to alarmIgnore (1) results in … |
| 1.3.6.1.4.1.318.1.1.7.2.5 | Nodedm3ConfigRelays | |||
| 1.3.6.1.4.1.318.1.1.7.2.5.1 | Nodedm3ConfigOutputRelays | |||
| 1.3.6.1.4.1.318.1.1.7.2.5.1.1 | Scalardm3ConfigOutRlyTableSize | read-only | mandatory | The number of DC powerplant Output Relays controllable by this IP address. |
| 1.3.6.1.4.1.318.1.1.7.2.5.1.2 | Tabledm3ConfigOutRlyTable | not-accessible | mandatory | Allows for accessing settings of the Output Relays. The number of entries is contained in the dm3ConfigOutRlyTableSize OID. |
| 1.3.6.1.4.1.318.1.1.7.2.5.1.2.1 | Rowdm3ConfigOutRlyEntry | not-accessible | mandatory | The output relay to configure. |
| 1.3.6.1.4.1.318.1.1.7.2.5.1.2.1.1 | Columndm3ConfigOutRlyIndex | read-only | mandatory | The index to the DC powerplant output relay. |
| 1.3.6.1.4.1.318.1.1.7.2.5.1.2.1.2 | Columndm3ConfigOutRlyName | read-write | mandatory | The name of the output relay. The maximum value is 16 characters. |
| 1.3.6.1.4.1.318.1.1.7.2.5.1.2.1.3 | Columndm3ConfigOutRlyDelay | read-write | mandatory | Output Relay Delay. This OID represents the time delay from the initiation of an output relay action to when the output relay action does occur. If the alarm c… |
| 1.3.6.1.4.1.318.1.1.7.2.5.1.2.1.4 | Columndm3ConfigOutRlyAlarm | read-write | mandatory | Output Relay Alarm. This setting indicates what action to perform in the event of an output relay alarm condition; Setting this OID to alarmIgnore (1) results … |
| 1.3.6.1.4.1.318.1.1.7.2.5.2 | Nodedm3ConfigInputRelays | |||
| 1.3.6.1.4.1.318.1.1.7.2.5.2.1 | Scalardm3ConfigInRlyTableSize | read-only | mandatory | The number of DC powerplant Input Relays controllable by this IP address. |
| 1.3.6.1.4.1.318.1.1.7.2.5.2.2 | Tabledm3ConfigInRlyTable | not-accessible | mandatory | Allows for accessing settings of the Input Relays. The number of entries is contained in the dm3ConfigInRlyTableSize OID. |
| 1.3.6.1.4.1.318.1.1.7.2.5.2.2.1 | Rowdm3ConfigInRlyEntry | not-accessible | mandatory | The input relay to configure. |
| 1.3.6.1.4.1.318.1.1.7.2.5.2.2.1.1 | Columndm3ConfigInRlyIndex | read-only | mandatory | The index to the DC powerplant input relay. |
| 1.3.6.1.4.1.318.1.1.7.2.5.2.2.1.2 | Columndm3ConfigInRlyName | read-write | mandatory | The name of the input relay. The maximum value is 16 characters. |
| 1.3.6.1.4.1.318.1.1.7.2.5.2.2.1.3 | Columndm3ConfigInRlyDelay | read-write | mandatory | Input Relay Delay. This OID represents the time delay from the initiation of an input relay action to when the input relay action does occur. If the alarm cond… |
| 1.3.6.1.4.1.318.1.1.7.2.5.2.2.1.4 | Columndm3ConfigInRlyAlarm | read-write | mandatory | Input Relay Alarm. This setting indicates what action to perform in the event of an input relay alarm condition; Setting this OID to alarmIgnore (1) results in… |
| 1.3.6.1.4.1.318.1.1.7.2.6 | Nodedm3ConfigDistribution | |||
| 1.3.6.1.4.1.318.1.1.7.2.6.1 | Nodedm3ConfigBreakers | |||
| 1.3.6.1.4.1.318.1.1.7.2.6.1.1 | Scalardm3ConfigBreakersTableSize | read-only | mandatory | The number of DC powerplant circuit breakers controllable by this IP address. |
| 1.3.6.1.4.1.318.1.1.7.2.6.1.2 | Tabledm3ConfigBreakersTable | not-accessible | mandatory | Allows for accessing settings of the circuit breakers. The number of entries is contained in the dm3ConfigBreakersTableSize OID. |
| 1.3.6.1.4.1.318.1.1.7.2.6.1.2.1 | Rowdm3ConfigBreakersEntry | not-accessible | mandatory | The circuit breaker to configure. |
| 1.3.6.1.4.1.318.1.1.7.2.6.1.2.1.1 | Columndm3ConfigBreakersIndex | read-only | mandatory | The index to the DC powerplant circuit breaker. |
| 1.3.6.1.4.1.318.1.1.7.2.6.1.2.1.2 | Columndm3ConfigBreakersName | read-write | mandatory | The name of the circuit breaker. The maximum value is 16 characters. |
| 1.3.6.1.4.1.318.1.1.7.2.6.1.2.1.3 | Columndm3ConfigBreakersAlarm | read-write | mandatory | Circuit Breaker Alarm. This setting indicates what action to perform in the event of a circuit breaker alarm condition; Setting this OID to alarmIgnore (1) res… |
| 1.3.6.1.4.1.318.1.1.7.2.6.2 | Nodedm3ConfigFuses | |||
| 1.3.6.1.4.1.318.1.1.7.2.6.2.1 | Scalardm3ConfigFusesTableSize | read-only | mandatory | The number of DC powerplant Fuses controllable by this IP address. |
| 1.3.6.1.4.1.318.1.1.7.2.6.2.2 | Tabledm3ConfigFusesTable | not-accessible | mandatory | Allows for accessing settings of the Fuses. The number of entries is contained in the dm3ConfigFusesTableSize OID. |
| 1.3.6.1.4.1.318.1.1.7.2.6.2.2.1 | Rowdm3ConfigFusesEntry | not-accessible | mandatory | The fuse to configure. |
| 1.3.6.1.4.1.318.1.1.7.2.6.2.2.1.1 | Columndm3ConfigFusesIndex | read-only | mandatory | The index to the DC powerplant fuse. |
| 1.3.6.1.4.1.318.1.1.7.2.6.2.2.1.2 | Columndm3ConfigFusesName | read-write | mandatory | The name of the fuse. The maximum value is 16 characters. |
| 1.3.6.1.4.1.318.1.1.7.2.6.2.2.1.3 | Columndm3ConfigFusesAlarm | read-write | mandatory | Fuses Alarm. This setting indicates what action to perform in the event of a Fuse alarm condition; Setting this OID to alarmIgnore (1) results in the alarm con… |
| 1.3.6.1.4.1.318.1.1.7.3 | Nodedm3Status | |||
| 1.3.6.1.4.1.318.1.1.7.3.1 | Nodedm3StatusSystem | |||
| 1.3.6.1.4.1.318.1.1.7.3.1.1 | Scalardm3StatusSystemTemp | read-only | mandatory | System temperature based on sensor on Master Controller PCB. Values are represented in thousandths of a degree. Units are displayed in the scale shown in the '… |
| 1.3.6.1.4.1.318.1.1.7.3.1.2 | Scalardm3StatusSystemStart | read-only | mandatory | Time stamp at DC powerplant initialization. The time is represented as MMM,DD,YYYY,HH:MM:SS. |
| 1.3.6.1.4.1.318.1.1.7.3.1.3 | Scalardm3StatusSysRemoteAccess | read-only | mandatory | Remote Access indicator This setting indicates if configuration (write) access to the powerplant is enabled or disabled at the powerplant level. This value wil… |
| 1.3.6.1.4.1.318.1.1.7.3.1.4 | Scalardm3StatusSysSecurityLevel | read-only | mandatory | This variable shows the current active security access level of controller. This can only be changed directly from the front panel. |
| 1.3.6.1.4.1.318.1.1.7.3.1.5 | Scalardm3StatusSysTempSanity | read-only | mandatory | System temperature sanity indicator. Indicates if the system temperature is reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1) … |
| 1.3.6.1.4.1.318.1.1.7.3.1.6 | Scalardm3StatusSysAlarmState | read-only | mandatory | System Alarm State. Reflects the alarm status of the overall DC system. If a minor alarm is present, the value will be alarmMinor(1). If a major alarm is prese… |
| 1.3.6.1.4.1.318.1.1.7.3.1.7 | Scalardm3StatusSysTempUnits | read-only | mandatory | The temperature scale used to display the temperature in the DC system, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configurat… |
| 1.3.6.1.4.1.318.1.1.7.3.2 | Nodedm3StatusAlarms | |||
| 1.3.6.1.4.1.318.1.1.7.3.2.1 | Scalardm3StatusAlarmsTableSize | read-only | mandatory | The number of DC powerplant alarms viewable by this IP address. |
| 1.3.6.1.4.1.318.1.1.7.3.2.2 | Tabledm3StatusAlarmsTable | not-accessible | mandatory | Allows for accessing system alarms. The number of entries is contained in the dm3StatusAlarmsTableSize OID. |
| 1.3.6.1.4.1.318.1.1.7.3.2.2.1 | Rowdm3StatusAlarmsEntry | not-accessible | mandatory | The alarm to display. |
| 1.3.6.1.4.1.318.1.1.7.3.2.2.1.1 | Columndm3StatusAlarmsIndex | read-only | mandatory | The index of the system alarm. |
| 1.3.6.1.4.1.318.1.1.7.3.2.2.1.2 | Columndm3StatusAlarmsText | read-only | mandatory | The 16 character text describing the active alarm condition. |
| 1.3.6.1.4.1.318.1.1.7.3.3 | Nodedm3StatusBattery | |||
| 1.3.6.1.4.1.318.1.1.7.3.3.1 | Scalardm3StatusBattCurrent | read-only | mandatory | Battery Current: This OID shows the battery current in thousandths of Amps (mA). |
| 1.3.6.1.4.1.318.1.1.7.3.3.2 | Scalardm3StatusBattTemp | read-only | mandatory | Battery Temperature: Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dm3StatusSysTempUnits' OID (Celsius or F… |
| 1.3.6.1.4.1.318.1.1.7.3.3.3 | Scalardm3StatusBattCurrentSanity | read-only | mandatory | Battery current sanity indicator. Indicates if the battery current is reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1) indica… |
| 1.3.6.1.4.1.318.1.1.7.3.3.4 | Scalardm3StatusBattTempSanity | read-only | mandatory | Battery temperature sanity indicator. Indicates if the battery temperature is reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1… |
| 1.3.6.1.4.1.318.1.1.7.3.4 | Nodedm3StatusOEM | |||
| 1.3.6.1.4.1.318.1.1.7.3.4.1 | Scalardm3StatusOEMrectOffset | read-only | mandatory | This OID shows the rectifier offset value in thousandths of Volts (mV). |
| 1.3.6.1.4.1.318.1.1.7.3.4.2 | Scalardm3StatusOEMrectGain | read-only | mandatory | This OID shows the rectifier gain value in thousandths of Volts (mV/V). |
| 1.3.6.1.4.1.318.1.1.7.3.4.3 | Scalardm3StatusOEMconvOffset | read-only | mandatory | This OID shows the converter offset value in thousandths of Volts (mV). |
| 1.3.6.1.4.1.318.1.1.7.3.4.4 | Scalardm3StatusOEMconvGain | read-only | mandatory | This OID shows the converter gain value in thousandths of Volts (mV/V). |
| 1.3.6.1.4.1.318.1.1.7.3.4.5 | Scalardm3StatusOEMshuntOffset | read-only | mandatory | This OID shows the shunt offset value in thousandths of Amps (mA). |
| 1.3.6.1.4.1.318.1.1.7.3.4.6 | Scalardm3StatusOEMshuntGain | read-only | mandatory | This OID shows the shunt gain value in thousandths of Amps (mA/A). |
| 1.3.6.1.4.1.318.1.1.7.3.5 | Nodedm3StatusLVD | |||
| 1.3.6.1.4.1.318.1.1.7.3.5.1 | Scalardm3StatusLVDTableSize | read-only | mandatory | The number of DC powerplant LVDs viewable by this IP address. |
| 1.3.6.1.4.1.318.1.1.7.3.5.2 | Tabledm3StatusLVDTable | not-accessible | mandatory | Allows for accessing settings of the LVDs. The number of entries is contained in the dm3StatusLVDTableSize OID. |
| 1.3.6.1.4.1.318.1.1.7.3.5.2.1 | Rowdm3StatusLVDEntry | not-accessible | mandatory | The LVD to gather status from. |
| 1.3.6.1.4.1.318.1.1.7.3.5.2.1.1 | Columndm3StatusLVDIndex | read-only | mandatory | The index to the DC powerplant LVD. |
| 1.3.6.1.4.1.318.1.1.7.3.5.2.1.2 | Columndm3StatusLVDName | read-only | mandatory | The name of the LVD. The maximum size is 16 characters. The name is set by using the dm3ConfigLVDName OID. This OID is provided for informational purposes only. |
| 1.3.6.1.4.1.318.1.1.7.3.5.2.1.3 | Columndm3StatusLVDState | read-only | mandatory | Getting this OID will return statusClosed (1) if the LVD is closed. statusOpened (2) will be returned if the LVD is opened. |
| 1.3.6.1.4.1.318.1.1.7.3.5.2.1.4 | Columndm3StatusLVDHwFault | read-only | mandatory | Getting this OID will return statusFault (1) if the LVD is faulted. statusNofault (2) will be returned if the LVD is not faulted. |
| 1.3.6.1.4.1.318.1.1.7.3.6 | Nodedm3StatusPowerModules | |||
| 1.3.6.1.4.1.318.1.1.7.3.6.1 | Nodedm3StatusRectifier | |||
| 1.3.6.1.4.1.318.1.1.7.3.6.1.1 | Scalardm3StatusRectTableSize | read-only | mandatory | The number of DC powerplant rectifiers viewable by this IP address. |
| 1.3.6.1.4.1.318.1.1.7.3.6.1.2 | Tabledm3StatusRectTable | not-accessible | mandatory | Allows for accessing settings of the rectifiers. The number of entries is contained in the dm3StatusRectTableSize OID. |
| 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1 | Rowdm3StatusRectEntry | not-accessible | mandatory | The rectifier to gather status from. |
| 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.1 | Columndm3StatusRectIndex | read-only | mandatory | The index to the DC powerplant rectifier. |
| 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.2 | Columndm3StatusRectID | read-only | mandatory | This OID shows the rectifier ID. This enumerates the number of the rectifier within a group of rectifiers. |
| 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.3 | Columndm3StatusRectDesc | read-only | mandatory | This OID shows the 16-character rectifier description. |
| 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.4 | Columndm3StatusRectCurrent | read-only | mandatory | This OID shows the rectifier current in thousandths of Amps (mA). |
| 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.5 | Columndm3StatusRectCurrentLimit | read-only | mandatory | Getting this OID will return statusTrue (1) if the rectifier is in the Current Limit state. statusFalse (2) will be returned if the rectifier is not in the Cur… |
| 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.6 | Columndm3StatusRectStandby | read-only | mandatory | Getting this OID will return statusTrue (1) if the rectifier is in the Standby state. statusFalse (2) will be returned if the rectifier is not in the Standby s… |
| 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.7 | Columndm3StatusRectFanFail | read-only | mandatory | Getting this OID will return statusTrue (1) if the rectifier Fan has failed. statusFalse (2) will be returned if the rectifier Fan has not failed. |
| 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.8 | Columndm3StatusRectFail | read-only | mandatory | Getting this OID will return statusTrue (1) if the rectifier has failed. statusFalse (2) will be returned if the rectifier has not failed. |
| 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.9 | Columndm3StatusRectDevType | read-only | mandatory | This OID shows the rectifier device type. |
| 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.10 | Columndm3StatusRectPhyAddr | read-only | mandatory | This OID shows the rectifier physical address (the address on the bus). |
| 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.11 | Columndm3StatusRectCfg | read-only | mandatory | Getting this OID will return statusTrue (1) if the rectifier is present after power-up or set-configuration. statusFalse (2) will be returned if the rectifier … |
| 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.12 | Columndm3StatusRectPcbRev | read-only | mandatory | This OID shows the rectifier device PCB serial number. |
| 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.13 | Columndm3StatusRectFwVer | read-only | mandatory | This OID shows the rectifier device firmware revision. |
| 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.14 | Columndm3StatusRectPresent | read-only | mandatory | Getting this OID will return statusTrue (1) if the rectifier is present. statusFalse (2) will be returned if the rectifier is not present. |
| 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.15 | Columndm3StatusRectDiagPass | read-only | mandatory | Getting this OID will return statusTrue (1) if the rectifier diagnostics have passed. statusFalse (2) will be returned if the rectifier diagnostics have not pa… |
| 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.16 | Columndm3StatusRectState | read-only | mandatory | This OID shows the rectifier device state as defined by the device status register. |
| 1.3.6.1.4.1.318.1.1.7.3.6.1.3 | Scalardm3StatusSysRectVoltSanity | read-only | mandatory | Rectifier voltage sanity indicator. Indicates if the rectifier voltage is reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1) in… |
| 1.3.6.1.4.1.318.1.1.7.3.6.1.4 | Scalardm3StatusSysRectAvailable | read-only | mandatory | Getting this OID will return statusTrue (1) if the rectifier is available. statusFalse (2) will be returned if the rectifier is not available. |
| 1.3.6.1.4.1.318.1.1.7.3.6.1.5 | Scalardm3StatusSysRectType | read-only | mandatory | This OID shows the type of rectifier the system has. There can only be a single type of rectifier in the power plant |
| 1.3.6.1.4.1.318.1.1.7.3.6.1.6 | Scalardm3StatusSysRectVoltage | read-only | mandatory | This OID shows the system level rectifier voltage in thousandths of Volts (mV). |
| 1.3.6.1.4.1.318.1.1.7.3.6.1.7 | Scalardm3StatusSysRectCurrent | read-only | mandatory | This OID shows the system level rectifier current in thousandths of Amps (mA). |
| 1.3.6.1.4.1.318.1.1.7.3.6.2 | Nodedm3StatusConverter | |||
| 1.3.6.1.4.1.318.1.1.7.3.6.2.1 | Scalardm3StatusConvTableSize | read-only | mandatory | The number of DC powerplant converters viewable by this IP address. |
| 1.3.6.1.4.1.318.1.1.7.3.6.2.2 | Tabledm3StatusConvTable | not-accessible | mandatory | Allows for viewing status of the converters. The number of entries is contained in the dm3StatusConvTableSize OID. |
| 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1 | Rowdm3StatusConvEntry | not-accessible | mandatory | The converter to gather status from. |
| 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.1 | Columndm3StatusConvIndex | read-only | mandatory | The index to the DC powerplant converter. |
| 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.2 | Columndm3StatusConvID | read-only | mandatory | This OID shows the converter ID. This enumerates the number of the converter within a group of converters. |
| 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.3 | Columndm3StatusConvDesc | read-only | mandatory | This OID shows the 16 character converter description. |
| 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.4 | Columndm3StatusConvCurrent | read-only | mandatory | This OID shows the converter current in thousandths of Amps (mA). |
| 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.5 | Columndm3StatusConvCurrentLimit | read-only | mandatory | Getting this OID will return statusTrue (1) if the converter is in the Current Limit state. statusFalse (2) will be returned if the converter is not in the Cur… |
| 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.6 | Columndm3StatusConvStandby | read-only | mandatory | Getting this OID will return statusTrue (1) if the converter is in the Standby state. statusFalse (2) will be returned if the converter is not in the Standby s… |
| 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.7 | Columndm3StatusConvFanFail | read-only | mandatory | Getting this OID will return statusTrue (1) if the converter Fan has failed. statusFalse (2) will be returned if the converter Fan has not failed. |
| 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.8 | Columndm3StatusConvFail | read-only | mandatory | Getting this OID will return statusTrue (1) if the converter has failed. statusFalse (2) will be returned if the converter has not failed. |
| 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.9 | Columndm3StatusConvDevType | read-only | mandatory | This OID shows the converter device type. |
| 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.10 | Columndm3StatusConvPhyAddr | read-only | mandatory | This OID shows the converter physical address (the address on the bus). |
| 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.11 | Columndm3StatusConvCfg | read-only | mandatory | Getting this OID will return statusTrue (1) if the converter is present after power-up or set-configuration. statusFalse (2) will be returned if the converter … |
| 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.12 | Columndm3StatusConvPcbRev | read-only | mandatory | This OID shows the converter device PCB serial number. |
| 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.13 | Columndm3StatusConvFwVer | read-only | mandatory | This OID shows the converter device firmware version. |
| 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.14 | Columndm3StatusConvPresent | read-only | mandatory | Getting this OID will return statusTrue (1) if the converter is present. statusFalse (2) will be returned if the converter is not present. |
| 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.15 | Columndm3StatusConvDiagPass | read-only | mandatory | Getting this OID will return statusTrue (1) if the converter diagnostics have passed. statusFalse (2) will be returned if the converter diagnostics have not pa… |
| 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.16 | Columndm3StatusConvState | read-only | mandatory | This OID shows the converter state as defined by the device status register. |
| 1.3.6.1.4.1.318.1.1.7.3.6.2.3 | Scalardm3StatusSysConvVoltSanity | read-only | mandatory | Converter voltage sanity indicator. Indicates if the converter voltage is reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1) in… |
| 1.3.6.1.4.1.318.1.1.7.3.6.2.4 | Scalardm3StatusSysConvAvailable | read-only | mandatory | Getting this OID will return statusTrue (1) if the converter is available. statusFalse (2) will be returned if the converter is not available. |
| 1.3.6.1.4.1.318.1.1.7.3.6.2.5 | Scalardm3StatusSysConvType | read-only | mandatory | This OID shows the converter type. |
| 1.3.6.1.4.1.318.1.1.7.3.6.2.6 | Scalardm3StatusSysConvVoltage | read-only | mandatory | This OID shows the system level converter voltage in thousandths of volts (mV). |
| 1.3.6.1.4.1.318.1.1.7.3.6.2.7 | Scalardm3StatusSysConvCurrent | read-only | mandatory | This OID shows the system level converter current in thousandths of Amps (mA). |
| 1.3.6.1.4.1.318.1.1.7.3.7 | Nodedm3StatusRelays | |||
| 1.3.6.1.4.1.318.1.1.7.3.7.1 | Nodedm3StatusOutputRelays | |||
| 1.3.6.1.4.1.318.1.1.7.3.7.1.1 | Scalardm3StatusOutRlyTableSize | read-only | mandatory | The number of DC powerplant output relays viewable by this IP address. |
| 1.3.6.1.4.1.318.1.1.7.3.7.1.2 | Tabledm3StatusOutRlyTable | not-accessible | mandatory | Allows for viewing status of the output relays. The number of entries is contained in the dm3StatusOutRlyTableSize OID. |
| 1.3.6.1.4.1.318.1.1.7.3.7.1.2.1 | Rowdm3StatusOutRlyEntry | not-accessible | mandatory | The output relay to gather status from. |
| 1.3.6.1.4.1.318.1.1.7.3.7.1.2.1.1 | Columndm3StatusOutRlyIndex | read-only | mandatory | The index to the DC powerplant output relay. |
| 1.3.6.1.4.1.318.1.1.7.3.7.1.2.1.2 | Columndm3StatusOutRlyName | read-only | mandatory | The name of the output relay. The maximum size is 16 characters. The name is set by using the dm3ConfigOutRlyName OID. This OID is provided for informational p… |
| 1.3.6.1.4.1.318.1.1.7.3.7.1.2.1.3 | Columndm3StatusOutRlyStatus | read-only | mandatory | Getting this OID will return statusOn (1) if the output relay is enabled/on. statusOff (2) will be returned if the output relay is disabled/off. |
| 1.3.6.1.4.1.318.1.1.7.3.7.2 | Nodedm3StatusInputRelays | |||
| 1.3.6.1.4.1.318.1.1.7.3.7.2.1 | Scalardm3StatusInRlyTableSize | read-only | mandatory | The number of DC powerplant input relays viewable by this IP address. |
| 1.3.6.1.4.1.318.1.1.7.3.7.2.2 | Tabledm3StatusInRlyTable | not-accessible | mandatory | Allows for viewing status of the input relays. The number of entries is contained in the dm3StatusInRlyTableSize OID. |
| 1.3.6.1.4.1.318.1.1.7.3.7.2.2.1 | Rowdm3StatusInRlyEntry | not-accessible | mandatory | The input relays to gather status from. |
| 1.3.6.1.4.1.318.1.1.7.3.7.2.2.1.1 | Columndm3StatusInRlyIndex | read-only | mandatory | The index to the DC powerplant input relay. |
| 1.3.6.1.4.1.318.1.1.7.3.7.2.2.1.2 | Columndm3StatusInRlyName | read-only | mandatory | The name of the input relay. The maximum size is 16 characters. The name is set by using the dm3ConfigInRlyName OID. This OID is provided for informational pur… |
| 1.3.6.1.4.1.318.1.1.7.3.7.2.2.1.3 | Columndm3StatusInRlyStatus | read-only | mandatory | Getting this OID will return statusOn (1) if the input relay is enabled/on. statusOff (2) will be returned if the input relay is disabled/off. |
| 1.3.6.1.4.1.318.1.1.7.3.8 | Nodedm3StatusDistribution | |||
| 1.3.6.1.4.1.318.1.1.7.3.8.1 | Nodedm3StatusBreakers | |||
| 1.3.6.1.4.1.318.1.1.7.3.8.1.1 | Scalardm3StatusBreakersTableSize | read-only | mandatory | The number of DC powerplant circuit breakers viewable by this IP address. |
| 1.3.6.1.4.1.318.1.1.7.3.8.1.2 | Tabledm3StatusBreakersTable | not-accessible | mandatory | Allows for viewing status of the circuit breakers. The number of entries is contained in the dm3StatusBreakersTableSize OID. |
| 1.3.6.1.4.1.318.1.1.7.3.8.1.2.1 | Rowdm3StatusBreakersEntry | not-accessible | mandatory | The circuit breaker to gather status from. |
| 1.3.6.1.4.1.318.1.1.7.3.8.1.2.1.1 | Columndm3StatusBreakersIndex | read-only | mandatory | The index to the DC powerplant circuit breaker. |
| 1.3.6.1.4.1.318.1.1.7.3.8.1.2.1.2 | Columndm3StatusBreakersName | read-only | mandatory | The name of the circuit breaker. The maximum size is 16 characters. The name is set by using the dm3ConfigBreakersName OID. This OID is provided for informatio… |
| 1.3.6.1.4.1.318.1.1.7.3.8.1.2.1.3 | Columndm3StatusBreakersStatus | read-only | mandatory | Getting this OID will return statusClosed (1) if the circuit breaker is closed. statusOpen (2) will be returned if the circuit breaker is open. |
| 1.3.6.1.4.1.318.1.1.7.3.8.2 | Nodedm3StatusFuses | |||
| 1.3.6.1.4.1.318.1.1.7.3.8.2.1 | Scalardm3StatusFusesTableSize | read-only | mandatory | The number of DC powerplant fuses controllable by this IP address. |
| 1.3.6.1.4.1.318.1.1.7.3.8.2.2 | Tabledm3StatusFusesTable | not-accessible | mandatory | Allows for viewing status of the fuses. The number of entries is contained in the dm3StatusFusesTableSize OID. |
| 1.3.6.1.4.1.318.1.1.7.3.8.2.2.1 | Rowdm3StatusFusesEntry | not-accessible | mandatory | The fuse to gather status from. |
| 1.3.6.1.4.1.318.1.1.7.3.8.2.2.1.1 | Columndm3StatusFusesIndex | read-only | mandatory | The index to the DC powerplant fuse. |
| 1.3.6.1.4.1.318.1.1.7.3.8.2.2.1.2 | Columndm3StatusFusesName | read-only | mandatory | The name of the fuse. The maximum size is 16 characters. The name is set by using the dm3ConfigFuseName OID. This OID is provided for informational purposes on… |
| 1.3.6.1.4.1.318.1.1.7.3.8.2.2.1.3 | Columndm3StatusFusesStatus | read-only | mandatory | Getting this OID will return statusClosed (1) if the fuse is closed. statusOpen (2) will be returned if the fuse is open. |
| 1.3.6.1.4.1.318.1.1.8 | NodeautomaticTransferSwitch | |||
| 1.3.6.1.4.1.318.1.1.8.1 | NodeatsIdent | |||
| 1.3.6.1.4.1.318.1.1.8.1.1 | ScalaratsIdentHardwareRev | read-only | mandatory | The hardware revision of the Automatic Transfer Switch. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.8.1.2 | ScalaratsIdentFirmwareRev | read-only | mandatory | A string identifying the Automatic Transfer Switch firmware revision. |
| 1.3.6.1.4.1.318.1.1.8.1.3 | ScalaratsIdentFirmwareDate | read-only | mandatory | The date of release for this Automatic Transfer Switch firmware revision. |
| 1.3.6.1.4.1.318.1.1.8.1.4 | ScalaratsIdentDateOfManufacture | read-only | mandatory | The date when the Automatic Transfer Switch was manufactured in mm/dd/yyyy format. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.8.1.5 | ScalaratsIdentModelNumber | read-only | mandatory | A string identifying the model number of the Automatic Transfer Switch. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.8.1.6 | ScalaratsIdentSerialNumber | read-only | mandatory | A string identifying the serial number of the Automatic Transfer Switch. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.8.1.7 | ScalaratsIdentNominalLineVoltage | read-only | mandatory | RMS Utility Voltage measured in Volts. |
| 1.3.6.1.4.1.318.1.1.8.1.8 | ScalaratsIdentNominalLineFrequency | read-only | mandatory | Utility Power Frequency measured in Hertz. |
| 1.3.6.1.4.1.318.1.1.8.1.9 | ScalaratsIdentDeviceRating | read-only | mandatory | This gives the device rating in Amps |
| 1.3.6.1.4.1.318.1.1.8.2 | NodeatsCalibration | |||
| 1.3.6.1.4.1.318.1.1.8.2.1 | NodeatsCalibrationInput | |||
| 1.3.6.1.4.1.318.1.1.8.2.1.1 | ScalaratsCalibrationNumInputs | read-only | mandatory | The number of inputs to this device. |
| 1.3.6.1.4.1.318.1.1.8.2.1.2 | ScalaratsCalibrationNumInputPhases | read-only | mandatory | The number of phases per input for this device. |
| 1.3.6.1.4.1.318.1.1.8.2.1.3 | TableatsCalibrationInputPhaseTable | not-accessible | mandatory | The number of phases per input line to this device. |
| 1.3.6.1.4.1.318.1.1.8.2.1.3.1 | RowatsCalibrationInputPhaseEntry | not-accessible | mandatory | An entry containing calibration information applicable to a particular input phase. |
| 1.3.6.1.4.1.318.1.1.8.2.1.3.1.1 | ColumnatsCalibrationInputTableIndex | read-only | mandatory | The input identifier. |
| 1.3.6.1.4.1.318.1.1.8.2.1.3.1.2 | ColumnatsCalibrationInputPhaseTableIndex | read-only | mandatory | The input phase identifier. |
| 1.3.6.1.4.1.318.1.1.8.2.1.3.1.3 | ColumnatsLineVoltageCalibrationFactor | read-only | mandatory | The Line Voltage Calibration factor. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.8.2.2 | NodeatsCalibrationPowerSupply | |||
| 1.3.6.1.4.1.318.1.1.8.2.2.1 | ScalaratsCalibrationPowerSupplyVoltages | read-only | mandatory | The number of power supply voltages supported by this device. This variable indicates the number of rows in the atsCalibrationPowerSupplyTable. |
| 1.3.6.1.4.1.318.1.1.8.2.2.2 | TableatsCalibrationPowerSupplyVoltageTable | not-accessible | mandatory | A list of Power Supply table entries. |
| 1.3.6.1.4.1.318.1.1.8.2.2.2.1 | RowatsCalibrationPowerSupplyVoltageEntry | not-accessible | mandatory | An entry containing information applicable to a particular Power Supply Voltage. |
| 1.3.6.1.4.1.318.1.1.8.2.2.2.1.1 | ColumnatsCalibrationPowerSupplyVoltageTableIndex | read-only | mandatory | The power supply voltage identifier. |
| 1.3.6.1.4.1.318.1.1.8.2.2.2.1.2 | ColumnatsCalibrationPowerSupplyVoltage | read-only | mandatory | This value describes the power supply voltage of 24V Source A, 24V Source B, +12V, -12V and 5V. |
| 1.3.6.1.4.1.318.1.1.8.2.2.2.1.3 | ColumnatsPowerSupplyVoltageCalibrationFactor | read-only | mandatory | The Line Voltage Calibration factor. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.8.2.2.3 | Tableats4gCalibrationPowerSupplyVoltageTable | not-accessible | mandatory | A list of Power Supply table entries. It is not applicable to AP77xx ATS units. |
| 1.3.6.1.4.1.318.1.1.8.2.2.3.1 | Rowats4gCalibrationPowerSupplyVoltageEntry | not-accessible | mandatory | An entry containing information applicable to a particular Power Supply Voltage. It is not applicable to AP77xx ATS units. |
| 1.3.6.1.4.1.318.1.1.8.2.2.3.1.1 | Columnats4gCalibrationPowerSupplyVoltageTableIndex | read-only | mandatory | The power supply voltage identifier. It is not applicable to AP77xx ATS units. |
| 1.3.6.1.4.1.318.1.1.8.2.2.3.1.2 | Columnats4gCalibrationPowerSupplyVoltage | read-only | mandatory | This value describes the power supply voltage of 24V Source A, 24V Source B, VBoost Source A, VBoost Source B, 3.3V, 1.0V. It is not applicable to AP77xx ATS u… |
| 1.3.6.1.4.1.318.1.1.8.2.2.3.1.3 | Columnats4gPowerSupplyVoltageCalibrationFactor | read-only | mandatory | The Line Voltage Calibration factor. This value is set at the factory. It is not applicable to AP77xx ATS units. |
| 1.3.6.1.4.1.318.1.1.8.2.3 | NodeatsCalibrationOutput | |||
| 1.3.6.1.4.1.318.1.1.8.2.3.1 | ScalaratsCalibrationNumOutputs | read-only | mandatory | The number of output lines from this device. This variable indicates the number of rows in the atsCalibrationOutputTable. |
| 1.3.6.1.4.1.318.1.1.8.2.3.2 | ScalaratsCalibrationNumOutputPhases | read-only | mandatory | The number of output phases utilized in this device. |
| 1.3.6.1.4.1.318.1.1.8.2.3.3 | TableatsCalibrationOutputTable | not-accessible | mandatory | A list of output table entries. |
| 1.3.6.1.4.1.318.1.1.8.2.3.3.1 | RowatsCalibrationOutputEntry | not-accessible | mandatory | An entry containing information applicable to a particular output. |
| 1.3.6.1.4.1.318.1.1.8.2.3.3.1.1 | ColumnatsCalibrationOutputTableIndex | read-only | mandatory | The output identifier. |
| 1.3.6.1.4.1.318.1.1.8.2.3.3.1.2 | ColumnatsCalibrationOutputPhasesTableIndex | read-only | mandatory | Description of each calibration factor for each output phase utilized in this device and one for neutral. |
| 1.3.6.1.4.1.318.1.1.8.2.3.3.1.3 | ColumnatsOutputCurrentCalibrationFactor | read-only | mandatory | The output current calibration factor measured in Amps. |
| 1.3.6.1.4.1.318.1.1.8.2.3.4 | Tableats4gCalibrationOutputTable | not-accessible | mandatory | A list of output table entries. It is not applicable to AP77xx ATS units. |
| 1.3.6.1.4.1.318.1.1.8.2.3.4.1 | Rowats4gCalibrationOutputEntry | not-accessible | mandatory | An entry containing information applicable to a particular output. |
| 1.3.6.1.4.1.318.1.1.8.2.3.4.1.1 | Columnats4gCalibrationOutputTableIndex | read-only | mandatory | The output identifier. |
| 1.3.6.1.4.1.318.1.1.8.2.3.4.1.2 | Columnats4gCalibrationOutputPhasesTableIndex | read-only | mandatory | Description of each calibration factor for each output phase utilized in this device and one for neutral. Bank 1 and Bank 2 are for units with two circuit brea… |
| 1.3.6.1.4.1.318.1.1.8.2.3.4.1.3 | Columnats4gOutputCurrentCalibrationFactor | read-only | mandatory | The output current calibration factor measured in Amps. It is not applicable to AP7xxx ATS units. |
| 1.3.6.1.4.1.318.1.1.8.3 | NodeatsControl | |||
| 1.3.6.1.4.1.318.1.1.8.3.1 | ScalaratsControlResetATS | read-write | mandatory | Setting this variable will cause the Automatic Transfer Switch to perform a power-on reset. It is not applicable to AP44xx units. |
| 1.3.6.1.4.1.318.1.1.8.3.2 | ScalaratsControlClearAllAlarms | read-write | mandatory | Setting this variable will clear all alarms in the Automatic Transfer Switch. Returns (-1) if unsupported. |
| 1.3.6.1.4.1.318.1.1.8.4 | NodeatsConfig | |||
| 1.3.6.1.4.1.318.1.1.8.4.1 | ScalaratsConfigProductName | read-write | mandatory | A configurable character string. |
| 1.3.6.1.4.1.318.1.1.8.4.2 | ScalaratsConfigPreferredSource | read-write | mandatory | This variable returns the preferred source of power when both sources are OK. |
| 1.3.6.1.4.1.318.1.1.8.4.3 | ScalaratsConfigFrontPanelLockout | read-write | mandatory | Setting this variable to disableFrontPanel(1), prevents source preference configuration of the Automatic Transfer Switch via the Front Panel. Setting this vari… |
| 1.3.6.1.4.1.318.1.1.8.4.4 | ScalaratsConfigVoltageSensitivity | read-write | mandatory | This variable defines the sensitivity to changes in voltage: high(1) for best protection, low(2) for frequent small line voltage changes. |
| 1.3.6.1.4.1.318.1.1.8.4.5 | ScalaratsConfigTransferVoltageRange | read-write | mandatory | This variable defines the range of acceptable voltage from a power source. If the voltage measured from the selected input source is not within this range, the… |
| 1.3.6.1.4.1.318.1.1.8.4.6 | ScalaratsConfigCurrentLimit | read-write | mandatory | The threshold (in Amps) at which an Over Current Alarm will be generated. This OID returns the overload threshold value of the OID atsConfigPhaseOverLoadThresh… |
| 1.3.6.1.4.1.318.1.1.8.4.7 | ScalaratsConfigResetValues | read-write | mandatory | Resets the ATS configuration to its default values. Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.8.4.8 | ScalaratsConfigLineVRMS | read-write | mandatory | To configure the input RMS voltage. |
| 1.3.6.1.4.1.318.1.1.8.4.9 | ScalaratsConfigLineVRMSNarrowLimit | read-write | mandatory | To configure the Line VRMS Narrow Limit. |
| 1.3.6.1.4.1.318.1.1.8.4.10 | ScalaratsConfigLineVRMSMediumLimit | read-write | mandatory | To configure the Line VRMS Medium Limit. |
| 1.3.6.1.4.1.318.1.1.8.4.11 | ScalaratsConfigLineVRMSWideLimit | read-write | mandatory | To configure the Line VRMS Wide Limit. |
| 1.3.6.1.4.1.318.1.1.8.4.12 | ScalaratsConfigFrequencyDeviation | read-write | mandatory | To configure the frequency deviation. AP77xx units uses the options of 1, 2, or 3. AP44xx units uses the options of 3, 5, or 10. |
| 1.3.6.1.4.1.318.1.1.8.4.13 | ScalaratsConfigBankTableSize | read-only | mandatory | The size of the bank table. |
| 1.3.6.1.4.1.318.1.1.8.4.14 | TableatsConfigBankTable | not-accessible | mandatory | Allows for configuration of each ATS bank. |
| 1.3.6.1.4.1.318.1.1.8.4.14.1 | RowatsConfigBankEntry | not-accessible | mandatory | This gives access to bank current threshold |
| 1.3.6.1.4.1.318.1.1.8.4.14.1.1 | ColumnatsConfigBankTableIndex | read-only | mandatory | An index to the bank table entry. |
| 1.3.6.1.4.1.318.1.1.8.4.14.1.2 | ColumnatsConfigBank | read-only | mandatory | The bank number of an ATS |
| 1.3.6.1.4.1.318.1.1.8.4.14.1.3 | ColumnatsConfigBankLowLoadThreshold | read-write | mandatory | A threshold that indicates the current drawn is nearing a low consumption condition. It is represented in Amps. A warning will be issued when the load is less … |
| 1.3.6.1.4.1.318.1.1.8.4.14.1.4 | ColumnatsConfigBankNearOverLoadThreshold | read-write | mandatory | A threshold that indicates the current drawn is nearing an overload condition. It is represented in Amps. A warning will be issued when the load is greater tha… |
| 1.3.6.1.4.1.318.1.1.8.4.14.1.5 | ColumnatsConfigBankOverLoadThreshold | read-write | mandatory | A threshold that indicates the current drawn has entered an overload condition. It is represented in Amps. A warning will be issued when the load is greater th… |
| 1.3.6.1.4.1.318.1.1.8.4.15 | ScalaratsConfigPhaseTableSize | read-only | mandatory | The size of the phase table. |
| 1.3.6.1.4.1.318.1.1.8.4.16 | TableatsConfigPhaseTable | not-accessible | mandatory | Allows for configuration of each ATS phase. |
| 1.3.6.1.4.1.318.1.1.8.4.16.1 | RowatsConfigPhaseEntry | not-accessible | mandatory | This gives access to phase threshold |
| 1.3.6.1.4.1.318.1.1.8.4.16.1.1 | ColumnatsConfigPhaseTableIndex | read-only | mandatory | The index to the phase table entry. |
| 1.3.6.1.4.1.318.1.1.8.4.16.1.2 | ColumnatsConfigPhase | read-only | mandatory | The phase number of an ATS |
| 1.3.6.1.4.1.318.1.1.8.4.16.1.3 | ColumnatsConfigPhaseLowLoadThreshold | read-write | mandatory | A threshold that indicates the current drawn is nearing a low consumption condition. It is represented in Amps. A warning will be issued when the load is less … |
| 1.3.6.1.4.1.318.1.1.8.4.16.1.4 | ColumnatsConfigPhaseNearOverLoadThreshold | read-write | mandatory | A threshold that indicates the current drawn is nearing an overload condition. It is represented in Amps. A warning will be issued when the load is greater tha… |
| 1.3.6.1.4.1.318.1.1.8.4.16.1.5 | ColumnatsConfigPhaseOverLoadThreshold | read-write | mandatory | A threshold that indicates the current drawn has entered an overload condition. It is represented in Amps. A warning will be issued when the load is greater th… |
| 1.3.6.1.4.1.318.1.1.8.5 | NodeatsStatus | |||
| 1.3.6.1.4.1.318.1.1.8.5.1 | NodeatsStatusDeviceStatus | |||
| 1.3.6.1.4.1.318.1.1.8.5.1.1 | ScalaratsStatusCommStatus | read-only | mandatory | This variable returns the current communication status of the Automatic Transfer Switch. |
| 1.3.6.1.4.1.318.1.1.8.5.1.2 | ScalaratsStatusSelectedSource | read-only | mandatory | This variable returns the current source of power. |
| 1.3.6.1.4.1.318.1.1.8.5.1.3 | ScalaratsStatusRedundancyState | read-only | mandatory | This variable returns the current redundancy state of the ATS. atsRedundancyLost(1) indicates that the ATS is unable to switch over to the alternate power sour… |
| 1.3.6.1.4.1.318.1.1.8.5.1.4 | ScalaratsStatusOverCurrentState | read-only | mandatory | This variable returns the output current state of the ATS. atsOverCurrent(1) indicates that the ATS has exceeded the output current threshold and will not allo… |
| 1.3.6.1.4.1.318.1.1.8.5.1.5 | ScalaratsStatus5VPowerSupply | read-only | mandatory | This variable returns the present state of the ATS 5V power supply. atsPowerSupplyFailure(1) indicates the 5V power supply has failed and that the ATS serial p… |
| 1.3.6.1.4.1.318.1.1.8.5.1.6 | ScalaratsStatus24VPowerSupply | read-only | mandatory | This variable returns the present state of the ATS 24V power supply for Source A. atsPowerSupplyFailure(1) indicates the 24V power supply has failed and the AT… |
| 1.3.6.1.4.1.318.1.1.8.5.1.7 | ScalaratsStatus24VSourceBPowerSupply | read-only | mandatory | This variable returns the present state of the ATS 24V power supply for Source B. atsPowerSupplyFailure(1) indicates the 24V power supply has failed and the AT… |
| 1.3.6.1.4.1.318.1.1.8.5.1.8 | ScalaratsStatusPlus12VPowerSupply | read-only | mandatory | This variable returns the present state of the ATS 12V power supply. atsPowerSupplyFailure(1) indicates the 12V power supply has failed and the ATS is unable t… |
| 1.3.6.1.4.1.318.1.1.8.5.1.9 | ScalaratsStatusMinus12VPowerSupply | read-only | mandatory | This variable returns the present state of the ATS -12V power supply. atsPowerSupplyFailure(1) indicates the -12V power supply has failed and the ATS is unable… |
| 1.3.6.1.4.1.318.1.1.8.5.1.10 | ScalaratsStatusSwitchStatus | read-only | mandatory | This variable returns the status of the ATS. |
| 1.3.6.1.4.1.318.1.1.8.5.1.11 | ScalaratsStatusFrontPanel | read-only | mandatory | This variable returns the present state of the ATS front panel. locked(1): Front panel button cannot be used to change the sources. unlocked(2): Front panel bu… |
| 1.3.6.1.4.1.318.1.1.8.5.1.12 | ScalaratsStatusSourceAStatus | read-only | mandatory | This variable returns the status of the Source A. |
| 1.3.6.1.4.1.318.1.1.8.5.1.13 | ScalaratsStatusSourceBStatus | read-only | mandatory | This variable returns the status of the Source B. |
| 1.3.6.1.4.1.318.1.1.8.5.1.14 | ScalaratsStatusPhaseSyncStatus | read-only | mandatory | This variable returns the status of the phase synch. |
| 1.3.6.1.4.1.318.1.1.8.5.1.15 | ScalaratsStatusVoltageOutStatus | read-only | mandatory | This variable returns the output voltage status. |
| 1.3.6.1.4.1.318.1.1.8.5.1.16 | ScalaratsStatusHardwareStatus | read-only | mandatory | This variable returns the status of display board hardware. |
| 1.3.6.1.4.1.318.1.1.8.5.1.17 | ScalaratsStatus3dot3VPowerSupply | read-only | mandatory | This variable returns the present state of the ATS 3.3V power supply. atsPowerSupplyFailure(1) indicates the 3.3V power supply has failed. atsPowerSupplyOK(2) … |
| 1.3.6.1.4.1.318.1.1.8.5.1.18 | ScalaratsStatus1Dot0VPowerSupply | read-only | mandatory | This variable returns the present state of the ATS 1.0V power supply. atsPowerSupplyFailure(1) indicates the 1V power supply has failed. atsPowerSupplyOK(2) in… |
| 1.3.6.1.4.1.318.1.1.8.5.1.19 | ScalaratsStatusVBoostSourceA | read-only | mandatory | This variable returns the present state of the ATS Source A Boost 48V voltage. atsPowerSupplyFailure(1) indicates the ATS Source A Boost 48V voltage has failed… |
| 1.3.6.1.4.1.318.1.1.8.5.1.20 | ScalaratsStatusVBoostSourceB | read-only | mandatory | This variable returns the present state of the ATS Source B Boost 48V voltage. atsPowerSupplyFailure(1) indicates the ATS Source B Boost 48V voltage has failed… |
| 1.3.6.1.4.1.318.1.1.8.5.2 | NodeatsStatusResetValues | |||
| 1.3.6.1.4.1.318.1.1.8.5.2.1 | ScalaratsStatusResetMaxMinValues | read-write | mandatory | Resets the maximum and minimum ATS values: atsInputMaxVoltage, atsInputMinVoltage, atsInputMaxCurrent, atsInputMinCurrent, atsInputMaxPower, atsInputMinPower, … |
| 1.3.6.1.4.1.318.1.1.8.5.3 | NodeatsStatusInput | |||
| 1.3.6.1.4.1.318.1.1.8.5.3.1 | ScalaratsNumInputs | read-only | mandatory | The number of input feeds to this device. This variable indicates the number of rows in the input table. |
| 1.3.6.1.4.1.318.1.1.8.5.3.2 | TableatsInputTable | not-accessible | mandatory | A list of input table entries. The number of entries is given by the value of atsNumInputs. |
| 1.3.6.1.4.1.318.1.1.8.5.3.2.1 | RowatsInputEntry | not-accessible | mandatory | An entry containing information applicable to a particular input. |
| 1.3.6.1.4.1.318.1.1.8.5.3.2.1.1 | ColumnatsInputTableIndex | read-only | mandatory | The input identifier. |
| 1.3.6.1.4.1.318.1.1.8.5.3.2.1.2 | ColumnatsNumInputPhases | read-only | mandatory | The number of input phases utilized in this device. The sum of all the atsNumInputPhases variable indicates the number of rows in the input phase table. |
| 1.3.6.1.4.1.318.1.1.8.5.3.2.1.3 | ColumnatsInputVoltageOrientation | read-only | mandatory | The input voltage orientation: 1: unknown for this Source 2: singlePhase - phase 1 voltage is between Phase 1 and Neutral. 3: splitPhase - phase 1 voltage is b… |
| 1.3.6.1.4.1.318.1.1.8.5.3.2.1.4 | ColumnatsInputFrequency | read-only | mandatory | The input frequency in Hertz, or -1 if it's unsupported by this Source. |
| 1.3.6.1.4.1.318.1.1.8.5.3.2.1.5 | ColumnatsInputType | read-only | mandatory | The input type. |
| 1.3.6.1.4.1.318.1.1.8.5.3.2.1.6 | ColumnatsInputName | read-write | mandatory | A name given to a particular input. |
| 1.3.6.1.4.1.318.1.1.8.5.3.3 | TableatsInputPhaseTable | not-accessible | mandatory | A list of input table entries. The number of entries is given by the sum of the atsNumInputPhases. |
| 1.3.6.1.4.1.318.1.1.8.5.3.3.1 | RowatsInputPhaseEntry | not-accessible | mandatory | An entry containing information applicable to a particular input phase. |
| 1.3.6.1.4.1.318.1.1.8.5.3.3.1.1 | ColumnatsInputPhaseTableIndex | read-only | mandatory | The input identifier. |
| 1.3.6.1.4.1.318.1.1.8.5.3.3.1.2 | ColumnatsInputPhaseIndex | read-only | mandatory | The input phase identifier. |
| 1.3.6.1.4.1.318.1.1.8.5.3.3.1.3 | ColumnatsInputVoltage | read-only | mandatory | The input voltage in VAC, or -1 if it's unsupported by this Source. |
| 1.3.6.1.4.1.318.1.1.8.5.3.3.1.4 | ColumnatsInputMaxVoltage | read-only | mandatory | The maximum input voltage in VAC measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
| 1.3.6.1.4.1.318.1.1.8.5.3.3.1.5 | ColumnatsInputMinVoltage | read-only | mandatory | The minimum input voltage in VAC measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
| 1.3.6.1.4.1.318.1.1.8.5.3.3.1.6 | ColumnatsInputCurrent | read-only | mandatory | The input current in amperes, or -1 if it's unsupported by this Source. |
| 1.3.6.1.4.1.318.1.1.8.5.3.3.1.7 | ColumnatsInputMaxCurrent | read-only | mandatory | The maximum input current in amperes measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
| 1.3.6.1.4.1.318.1.1.8.5.3.3.1.8 | ColumnatsInputMinCurrent | read-only | mandatory | The minimum input current in amperes measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
| 1.3.6.1.4.1.318.1.1.8.5.3.3.1.9 | ColumnatsInputPower | read-only | mandatory | The input power in Watts, or -1 if it's unsupported by this Source. |
| 1.3.6.1.4.1.318.1.1.8.5.3.3.1.10 | ColumnatsInputMaxPower | read-only | mandatory | The maximum input power in Watts measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
| 1.3.6.1.4.1.318.1.1.8.5.3.3.1.11 | ColumnatsInputMinPower | read-only | mandatory | The minimum input power in Watts measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
| 1.3.6.1.4.1.318.1.1.8.5.4 | NodeatsStatusOutput | |||
| 1.3.6.1.4.1.318.1.1.8.5.4.1 | ScalaratsNumOutputs | read-only | mandatory | The number of output feeds to this device. This variable indicates the number of rows in the output table. |
| 1.3.6.1.4.1.318.1.1.8.5.4.2 | TableatsOutputTable | not-accessible | mandatory | A list of output table entries. The number of entries is given by the value of atsOutputNumPhases. |
| 1.3.6.1.4.1.318.1.1.8.5.4.2.1 | RowatsOutputEntry | not-accessible | mandatory | An entry containing information applicable to a particular output. |
| 1.3.6.1.4.1.318.1.1.8.5.4.2.1.1 | ColumnatsOutputTableIndex | read-only | mandatory | The output identifier. |
| 1.3.6.1.4.1.318.1.1.8.5.4.2.1.2 | ColumnatsNumOutputPhases | read-only | mandatory | The number of output phases utilized in this device. The sum of all the atsNumOutputPhases variable indicates the number of rows in the output phase table. |
| 1.3.6.1.4.1.318.1.1.8.5.4.2.1.3 | ColumnatsOutputVoltageOrientation | read-only | mandatory | The output voltage orientation: 1: unknown for this ATS 2: singlePhase - phase 1 voltage is between Phase 1 and Neutral. 3: splitPhase - phase 1 voltage is bet… |
| 1.3.6.1.4.1.318.1.1.8.5.4.2.1.4 | ColumnatsOutputFrequency | read-only | mandatory | The output frequency in Hertz, or -1 if it's unsupported by this ATS. |
| 1.3.6.1.4.1.318.1.1.8.5.4.3 | TableatsOutputPhaseTable | not-accessible | mandatory | A list of output table entries. The number of entries is given by the sum of the atsNumOutputPhases. |
| 1.3.6.1.4.1.318.1.1.8.5.4.3.1 | RowatsOutputPhaseEntry | not-accessible | mandatory | An entry containing information applicable to a particular output phase. |
| 1.3.6.1.4.1.318.1.1.8.5.4.3.1.1 | ColumnatsOutputPhaseTableIndex | read-only | mandatory | The output identifier. |
| 1.3.6.1.4.1.318.1.1.8.5.4.3.1.2 | ColumnatsOutputPhaseIndex | read-only | mandatory | Description of each output phase utilized in this device and one for neutral. |
| 1.3.6.1.4.1.318.1.1.8.5.4.3.1.3 | ColumnatsOutputVoltage | read-only | mandatory | The output voltage in VAC, or -1 if it's unsupported by this ATS. |
| 1.3.6.1.4.1.318.1.1.8.5.4.3.1.4 | ColumnatsOutputCurrent | read-only | mandatory | The output current in 0.1 amperes drawn by the load on the ATS, or -1 if it's unsupported by this ATS. |
| 1.3.6.1.4.1.318.1.1.8.5.4.3.1.5 | ColumnatsOutputMaxCurrent | read-only | mandatory | The maximum output current in 0.1 amperes measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupporte… |
| 1.3.6.1.4.1.318.1.1.8.5.4.3.1.6 | ColumnatsOutputMinCurrent | read-only | mandatory | The minimum output current in 0.1 amperes measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupporte… |
| 1.3.6.1.4.1.318.1.1.8.5.4.3.1.7 | ColumnatsOutputLoad | read-only | mandatory | The output load in VA, or -1 if it's unsupported by this ATS. |
| 1.3.6.1.4.1.318.1.1.8.5.4.3.1.8 | ColumnatsOutputMaxLoad | read-only | mandatory | The maximum output load in VA measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
| 1.3.6.1.4.1.318.1.1.8.5.4.3.1.9 | ColumnatsOutputMinLoad | read-only | mandatory | The minimum output load in VA measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
| 1.3.6.1.4.1.318.1.1.8.5.4.3.1.10 | ColumnatsOutputPercentLoad | read-only | mandatory | The percentage of the ATS load capacity in VA at redundancy @ (n + x) presently being used on this output phase, or -1 if it's unsupported by this ATS. |
| 1.3.6.1.4.1.318.1.1.8.5.4.3.1.11 | ColumnatsOutputMaxPercentLoad | read-only | mandatory | The maximum percentage of the ATS load capacity in VA measured at redundancy @ (n + x) presently being used on this output phase since the last time this varia… |
| 1.3.6.1.4.1.318.1.1.8.5.4.3.1.12 | ColumnatsOutputMinPercentLoad | read-only | mandatory | The minimum percentage of the ATS load capacity in VA measured at redundancy @ (n + x) presently being used on this output phase since the last time this varia… |
| 1.3.6.1.4.1.318.1.1.8.5.4.3.1.13 | ColumnatsOutputPower | read-only | mandatory | The output power in VA, or -1 if it's unsupported by this ATS. |
| 1.3.6.1.4.1.318.1.1.8.5.4.3.1.14 | ColumnatsOutputMaxPower | read-only | mandatory | The maximum output power in VAs measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
| 1.3.6.1.4.1.318.1.1.8.5.4.3.1.15 | ColumnatsOutputMinPower | read-only | mandatory | The minimum output power in VA measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
| 1.3.6.1.4.1.318.1.1.8.5.4.3.1.16 | ColumnatsOutputPercentPower | read-only | mandatory | The percentage of the ATSpower capacity in VA at redundancy @ (n + x) presently being used on this output phase, or -1 if it's unsupported by this ATS. |
| 1.3.6.1.4.1.318.1.1.8.5.4.3.1.17 | ColumnatsOutputMaxPercentPower | read-only | mandatory | The maximum percentage of the ATSpower capacity in VA measured at redundancy @ (n + x) presently being used on this output phase since the last time this varia… |
| 1.3.6.1.4.1.318.1.1.8.5.4.3.1.18 | ColumnatsOutputMinPercentPower | read-only | mandatory | The minimum percentage of the ATSpower capacity in VA measured at redundancy @ (n + x) presently being used on this output phase since the last time this varia… |
| 1.3.6.1.4.1.318.1.1.8.5.4.3.1.19 | ColumnatsOutputPhaseState | read-only | mandatory | Getting this OID will return the phase load state. normal(1) indicates that the bank is operating properly within the atsConfigPhaseLowLoadThreshold and atsCon… |
| 1.3.6.1.4.1.318.1.1.8.5.4.4 | ScalaratsOutputBankTableSize | read-only | mandatory | The size of the bank table. |
| 1.3.6.1.4.1.318.1.1.8.5.4.5 | TableatsOutputBankTable | not-accessible | mandatory | Allows for getting table entries. |
| 1.3.6.1.4.1.318.1.1.8.5.4.5.1 | RowatsOutputBankEntry | not-accessible | mandatory | This gives access to bank table entries |
| 1.3.6.1.4.1.318.1.1.8.5.4.5.1.1 | ColumnatsOutputBankTableIndex | read-only | mandatory | The index to the bank table entry. |
| 1.3.6.1.4.1.318.1.1.8.5.4.5.1.2 | ColumnatsOutputPhase | read-only | mandatory | The phase number of an ATS |
| 1.3.6.1.4.1.318.1.1.8.5.4.5.1.3 | ColumnatsOutputBank | read-only | mandatory | The bank number of an ATS |
| 1.3.6.1.4.1.318.1.1.8.5.4.5.1.4 | ColumnatsOutputBankCurrent | read-only | mandatory | Getting this OID will return the bank current measured in tenths of Amps. |
| 1.3.6.1.4.1.318.1.1.8.5.4.5.1.5 | ColumnatsOutputBankState | read-only | mandatory | Getting this OID will return the bank load state. normal(1) indicates that the bank is operating properly within the atsConfigBankLowLoadThreshold and atsConfi… |
| 1.3.6.1.4.1.318.1.1.8.5.4.5.1.6 | ColumnatsOutputBankOutputVoltage | read-only | mandatory | The output voltage in VAC, or -1 if it's unsupported by this ATS. |
| 1.3.6.1.4.1.318.1.1.8.5.4.5.1.7 | ColumnatsOutputBankMaxCurrent | read-only | mandatory | The maximum output current, on the bank represented by OID atsOutputBank, in 0.1 amperes measured since the last time this variable was read or reset (atsStatu… |
| 1.3.6.1.4.1.318.1.1.8.5.4.5.1.8 | ColumnatsOutputBankMinCurrent | read-only | mandatory | The minimum output current, on the bank represented by OID atsOutputBank, in 0.1 amperes measured since the last time this variable was read or reset (atsStatu… |
| 1.3.6.1.4.1.318.1.1.8.5.4.5.1.9 | ColumnatsOutputBankLoad | read-only | mandatory | The output load, on the bank represented by OID atsOutputBank, in VA, or -1 if it's unsupported by this ATS. |
| 1.3.6.1.4.1.318.1.1.8.5.4.5.1.10 | ColumnatsOutputBankMaxLoad | read-only | mandatory | The maximum output load, on the bank represented by OID atsOutputBank, in VA measured since the last time this variable was read or reset (atsStatusResetMaxMin… |
| 1.3.6.1.4.1.318.1.1.8.5.4.5.1.11 | ColumnatsOutputBankMinLoad | read-only | mandatory | The minimum output load, on the bank represented by OID atsOutputBank, in VA measured since the last time this variable was read or reset (atsStatusResetMaxMin… |
| 1.3.6.1.4.1.318.1.1.8.5.4.5.1.12 | ColumnatsOutputBankPercentLoad | read-only | mandatory | The percentage of the ATS load capacity in VA at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank. Returns (-1) if unsu… |
| 1.3.6.1.4.1.318.1.1.8.5.4.5.1.13 | ColumnatsOutputBankMaxPercentLoad | read-only | mandatory | The maximum percentage of the ATS load capacity in VA measured at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank, sin… |
| 1.3.6.1.4.1.318.1.1.8.5.4.5.1.14 | ColumnatsOutputBankMinPercentLoad | read-only | mandatory | The minimum percentage of the ATS load capacity in VA measured at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank, sin… |
| 1.3.6.1.4.1.318.1.1.8.5.4.5.1.15 | ColumnatsOutputBankPower | read-only | mandatory | The output power in VA on the bank represented by OID atsOutputBank or -1 if it's unsupported by this ATS. |
| 1.3.6.1.4.1.318.1.1.8.5.4.5.1.16 | ColumnatsOutputBankMaxPower | read-only | mandatory | The maximum output power in VA measured on the bank represented by OID atsOutputBank since the last time this variable was read or reset (atsStatusResetMaxMinV… |
| 1.3.6.1.4.1.318.1.1.8.5.4.5.1.17 | ColumnatsOutputBankMinPower | read-only | mandatory | The minimum output power in VA measured on the bank represented by OID atsOutputBank since the last time this variable was read or reset (atsStatusResetMaxMinV… |
| 1.3.6.1.4.1.318.1.1.8.5.4.5.1.18 | ColumnatsOutputBankPercentPower | read-only | mandatory | The percentage of the ATSpower capacity in Watts at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank, or -1 if it's uns… |
| 1.3.6.1.4.1.318.1.1.8.5.4.5.1.19 | ColumnatsOutputBankMaxPercentPower | read-only | mandatory | The maximum percentage of the ATSpower capacity in VA measured at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank, sin… |
| 1.3.6.1.4.1.318.1.1.8.5.4.5.1.20 | ColumnatsOutputBankMinPercentPower | read-only | mandatory | The minimum percentage of the ATSpower capacity in VA measured at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank sinc… |
| 1.3.6.1.4.1.318.1.1.9 | Nodedc2 | |||
| 1.3.6.1.4.1.318.1.1.9.1 | Nodedcmim2Ident | |||
| 1.3.6.1.4.1.318.1.1.9.1.1 | Nodedcmim2IdentSystem | |||
| 1.3.6.1.4.1.318.1.1.9.1.1.1 | Scalardcmim2IdentSysFWVersion | read-only | mandatory | Integer representation of the power plant Master Controller firmware revision. |
| 1.3.6.1.4.1.318.1.1.9.2 | Nodedcmim2Control | |||
| 1.3.6.1.4.1.318.1.1.9.2.1 | Nodedcmim2ControlSystem | |||
| 1.3.6.1.4.1.318.1.1.9.2.1.1 | Scalardcmim2ControlRunFunctBatteryTest | read-write | mandatory | Getting this OID will return the battery functional test state. If the test is off, the battTestOff (1) value will be returned. If the test is on, the battTest… |
| 1.3.6.1.4.1.318.1.1.9.2.1.2 | Scalardcmim2ControlRunCapacityBatteryTest | read-write | mandatory | Getting this OID will return the battery capacity test state. If the test is off, the battTestOff (1) value will be returned. If the test is on, the battTestOn… |
| 1.3.6.1.4.1.318.1.1.9.3 | Nodedcmim2Config | |||
| 1.3.6.1.4.1.318.1.1.9.3.1 | Nodedcmim2ConfigSystem | |||
| 1.3.6.1.4.1.318.1.1.9.3.1.1 | Scalardcmim2ConfigSysHighTempTrip | read-write | mandatory | Trip level (threshold) at which System High Temp alarm condition is created. Range 28 to 100 (degC). Values are represented in thousandths of a degree. Units a… |
| 1.3.6.1.4.1.318.1.1.9.3.1.2 | Scalardcmim2ConfigSysHighTempReset | read-write | mandatory | Level at which System High Temp alarm condition is reset (cleared). Range 25 to (upper temp - 3) (degC). Values are represented in thousandths of a degree. Uni… |
| 1.3.6.1.4.1.318.1.1.9.3.1.3 | Scalardcmim2ConfigSysLowTempTrip | read-write | mandatory | Trip level (threshold) at which System Low Temp alarm condition is created. Range -100 to 10 (degC). Values are represented in thousandths of a degree. Units a… |
| 1.3.6.1.4.1.318.1.1.9.3.1.4 | Scalardcmim2ConfigSysLowTempReset | read-write | mandatory | Level at which System Low Temp alarm condition is reset (cleared). Range (lower temp + 3) to 13 (degC). Values are represented in thousandths of a degree. Unit… |
| 1.3.6.1.4.1.318.1.1.9.3.2 | Nodedcmim2ConfigBattery | |||
| 1.3.6.1.4.1.318.1.1.9.3.2.1 | Scalardcmim2ConfigBattFloatVolt | read-write | mandatory | Battery Float Voltage defined at 25 degrees Celsius. Values are represented in thousandths of Volts (mV). |
| 1.3.6.1.4.1.318.1.1.9.3.2.2 | Scalardcmim2ConfigBattMaxRecharge | read-write | mandatory | Battery Maximum Recharge Rate. This is the maximum current used during battery charging. Values are represented in thousandths of Amps (mA). |
| 1.3.6.1.4.1.318.1.1.9.3.2.3 | Scalardcmim2ConfigBattMfgCapacity | read-write | mandatory | Battery capacity (Amp-Hour Size) as specified by the battery manufacturer. Values are represented in thousandths of Amp hours (mAHr). |
| 1.3.6.1.4.1.318.1.1.9.3.2.4 | Scalardcmim2ConfigBattType | read-write | mandatory | Type of battery in the powerplant Valid values range from 0 to 254. |
| 1.3.6.1.4.1.318.1.1.9.3.2.5 | Scalardcmim2ConfigBattFunctTestDuration | read-write | mandatory | Duration of the battery functional test. Values are represented in thousandths of seconds (mSecs). |
| 1.3.6.1.4.1.318.1.1.9.3.2.6 | Scalardcmim2ConfigBattFunctTestThresh | read-write | mandatory | Threshold the battery voltage of the system must remain above in order to pass the battery functional test. Values are represented in thousandths of Volts (mV). |
| 1.3.6.1.4.1.318.1.1.9.3.2.7 | Scalardcmim2ConfigBattCapacityTestPercent | read-write | mandatory | Threshold for good battery capacity test results. Values range from 0 to 100 percent. |
| 1.3.6.1.4.1.318.1.1.9.3.2.8 | Scalardcmim2ConfigBattCapacityTestEndThresh | read-write | mandatory | Safeguard voltage at which battery capacity test will end if there is a battery problem. Values are represented in thousandths of Volts (mV). |
| 1.3.6.1.4.1.318.1.1.9.3.2.9 | Scalardcmim2ConfigBattCapacityTestCurrent | read-write | mandatory | Constant current value used during battery capacity testing. Values are represented in thousandths of Amps (mA). |
| 1.3.6.1.4.1.318.1.1.9.3.3 | Nodedcmim2ConfigLVD | |||
| 1.3.6.1.4.1.318.1.1.9.3.3.1 | Scalardcmim2ConfigLVDTableSize | read-only | mandatory | The number of DC powerplant LVDs controllable by this IP address. |
| 1.3.6.1.4.1.318.1.1.9.3.3.2 | Tabledcmim2ConfigLVDTable | not-accessible | mandatory | Allows for accessing settings of the LVDs. The number of entries is contained in the dcmim2ConfigLVDTableSize OID. |
| 1.3.6.1.4.1.318.1.1.9.3.3.2.1 | Rowdcmim2ConfigLVDEntry | not-accessible | mandatory | The LVD to configure. |
| 1.3.6.1.4.1.318.1.1.9.3.3.2.1.1 | Columndcmim2ConfigLVDIndex | read-only | mandatory | The index to the DC powerplant LVD. |
| 1.3.6.1.4.1.318.1.1.9.3.3.2.1.2 | Columndcmim2ConfigLVDTrip | read-write | mandatory | LVD Trip threshold. System bus voltage at which LVD will trip (open) during a battery backup operation. Values are represented in thousandths of Volts (mV). |
| 1.3.6.1.4.1.318.1.1.9.3.3.2.1.3 | Columndcmim2ConfigLVDReset | read-write | mandatory | LVD Reset threshold. System bus voltage at which LVD will reset (close) after AC power has been restored. Values are represented in thousandths of Volts (mV). |
| 1.3.6.1.4.1.318.1.1.9.3.3.2.1.4 | Columndcmim2ConfigLVDState | read-only | mandatory | Getting this OID will return statusClosed (1) if the LVD is closed. statusOpened (2) will be returned if the LVD is opened. |
| 1.3.6.1.4.1.318.1.1.9.4 | Nodedcmim2Status | |||
| 1.3.6.1.4.1.318.1.1.9.4.1 | Nodedcmim2StatusSystem | |||
| 1.3.6.1.4.1.318.1.1.9.4.1.1 | Scalardcmim2StatusSysRectCurrent | read-only | mandatory | System (Total Rectifier) current in thousandths of Amps (mA). |
| 1.3.6.1.4.1.318.1.1.9.4.1.2 | Scalardcmim2StatusSysLoadCurrent | read-only | mandatory | Load current in thousandths of Amps (mA). |
| 1.3.6.1.4.1.318.1.1.9.4.1.3 | Scalardcmim2StatusSysBusVoltage | read-only | mandatory | System bus voltage in thousandths of Volts (mV). |
| 1.3.6.1.4.1.318.1.1.9.4.1.4 | Scalardcmim2StatusSysAmbientTemp | read-only | mandatory | System temperature based on sensor on Master Controller PCB. Values are represented in thousandths of a degree. Units are displayed in the scale shown in the '… |
| 1.3.6.1.4.1.318.1.1.9.4.1.5 | Scalardcmim2StatusSysUpTime | read-only | mandatory | Length of time since the DC Powerplant controller has been powered up. |
| 1.3.6.1.4.1.318.1.1.9.4.1.6 | Scalardcmim2StatusSysTempUnits | read-only | mandatory | The temperature scale used to display the temperature in the DC system, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configurat… |
| 1.3.6.1.4.1.318.1.1.9.4.2 | Nodedcmim2StatusRectifier | |||
| 1.3.6.1.4.1.318.1.1.9.4.2.1 | Scalardcmim2StatusRectTableSize | read-only | mandatory | The number of DC powerplant rectifiers viewable by this IP address. |
| 1.3.6.1.4.1.318.1.1.9.4.2.2 | Tabledcmim2StatusRectTable | not-accessible | mandatory | Allows for accessing settings of the rectifiers. The number of entries is contained in the dcmim2StatusRectTableSize OID. |
| 1.3.6.1.4.1.318.1.1.9.4.2.2.1 | Rowdcmim2StatusRectEntry | not-accessible | mandatory | The rectifier to gather status from. |
| 1.3.6.1.4.1.318.1.1.9.4.2.2.1.1 | Columndcmim2StatusRectIndex | read-only | mandatory | The index to the DC powerplant rectifier. |
| 1.3.6.1.4.1.318.1.1.9.4.2.2.1.2 | Columndcmim2StatusRectDevType | read-only | mandatory | This OID shows the rectifier device type. |
| 1.3.6.1.4.1.318.1.1.9.4.2.2.1.3 | Columndcmim2StatusRectID | read-only | mandatory | This OID shows the rectifier ID. This enumerates the number of the rectifier within a group of rectifiers. |
| 1.3.6.1.4.1.318.1.1.9.4.2.2.1.4 | Columndcmim2StatusRectPhyAddr | read-only | mandatory | This OID shows the rectifier physical address (the address on the bus). |
| 1.3.6.1.4.1.318.1.1.9.4.2.2.1.5 | Columndcmim2StatusRectFail | read-only | mandatory | Getting this OID will return statusTrue (1) if the rectifier has failed. statusFalse (2) will be returned if the rectifier has not failed. |
| 1.3.6.1.4.1.318.1.1.9.4.2.2.1.6 | Columndcmim2StatusRectCurrent | read-only | mandatory | This OID shows the individual rectifier current in thousandths of Amps (mA). |
| 1.3.6.1.4.1.318.1.1.9.4.3 | Nodedcmim2StatusBattery | |||
| 1.3.6.1.4.1.318.1.1.9.4.3.1 | Scalardcmim2StatusBattFloatVolt | read-only | mandatory | Battery Float Voltage represented in thousandths of Volts (mV). |
| 1.3.6.1.4.1.318.1.1.9.4.3.2 | Scalardcmim2StatusBattCurrent | read-only | mandatory | Battery Current: This OID shows the battery current in thousandths of Amps (mA). |
| 1.3.6.1.4.1.318.1.1.9.4.3.3 | Scalardcmim2StatusBattTemp | read-only | mandatory | Battery Temperature: Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dcmim2StatusSysTempUnits' OID (Celsius o… |
| 1.3.6.1.4.1.318.1.1.9.4.3.4 | Scalardcmim2StatusBattMfgCapacity | read-only | mandatory | Battery capacity (Amp-Hour Size) as specified by the battery manufacturer. Values are represented in thousandths of Amp hours (mAHr). |
| 1.3.6.1.4.1.318.1.1.9.4.3.5 | Scalardcmim2StatusBattTestCapacity | read-only | mandatory | Battery capacity (Amp-Hour Size) as determined by the battery capacity test. Values are represented in thousandths of Amp hours (mAHr). |
| 1.3.6.1.4.1.318.1.1.9.4.3.6 | Scalardcmim2StatusBattFunctTestResult | read-only | mandatory | Results of the last battery functional test that was run. |
| 1.3.6.1.4.1.318.1.1.9.4.3.7 | Scalardcmim2StatusBattCapacityTestResult | read-only | mandatory | Results of the last battery capacity test that was run. |
| 1.3.6.1.4.1.318.1.1.9.4.4 | Nodedcmim2StatusLVD | |||
| 1.3.6.1.4.1.318.1.1.9.4.4.1 | Scalardcmim2StatusLVDTableSize | read-only | mandatory | The number of DC powerplant LVDs accessible by this IP address. |
| 1.3.6.1.4.1.318.1.1.9.4.4.2 | Tabledcmim2StatusLVDTable | not-accessible | mandatory | Allows for accessing the LVDs. The number of entries is contained in the dcmim2StatusLVDTableSize OID. |
| 1.3.6.1.4.1.318.1.1.9.4.4.2.1 | Rowdcmim2StatusLVDEntry | not-accessible | mandatory | The LVD to access. |
| 1.3.6.1.4.1.318.1.1.9.4.4.2.1.1 | Columndcmim2StatusLVDIndex | read-only | mandatory | The index to the DC powerplant LVD. |
| 1.3.6.1.4.1.318.1.1.9.4.4.2.1.2 | Columndcmim2StatusLVDState | read-only | mandatory | Getting this OID will return statusClosed (1) if the LVD is closed. statusOpened (2) will be returned if the LVD is opened. |
| 1.3.6.1.4.1.318.1.1.9.4.5 | Nodedcmim2StatusAlarms | |||
| 1.3.6.1.4.1.318.1.1.9.4.5.1 | Scalardcmim2StatusAlarmsTableSize | read-only | mandatory | The number of DC powerplant alarms viewable by this IP address. |
| 1.3.6.1.4.1.318.1.1.9.4.5.2 | Tabledcmim2StatusAlarmsTable | not-accessible | mandatory | Allows for accessing system alarms. The number of entries is contained in the dcmim2StatusAlarmsTableSize OID. |
| 1.3.6.1.4.1.318.1.1.9.4.5.2.1 | Rowdcmim2StatusAlarmsEntry | not-accessible | mandatory | The alarm to display. |
| 1.3.6.1.4.1.318.1.1.9.4.5.2.1.1 | Columndcmim2StatusAlarmsIndex | read-only | mandatory | The index of the system alarm. |
| 1.3.6.1.4.1.318.1.1.9.4.5.2.1.2 | Columndcmim2StatusAlarmsText | read-only | mandatory | The 16 character text describing the active alarm condition. |
| 1.3.6.1.4.1.318.1.1.10 | NodeenvironmentalMonitor | |||
| 1.3.6.1.4.1.318.1.1.10.1 | Nodeexternal | |||
| 1.3.6.1.4.1.318.1.1.10.1.1 | NodeemIdent | |||
| 1.3.6.1.4.1.318.1.1.10.1.1.1 | ScalaremIdentFirmwareRevision | read-only | mandatory | The firmware revision of the Environmental Monitor. |
| 1.3.6.1.4.1.318.1.1.10.1.2 | NodeemConfig | |||
| 1.3.6.1.4.1.318.1.1.10.1.2.1 | ScalaremConfigProbesNumProbes | read-only | mandatory | The number of temperature and humidity probes available. |
| 1.3.6.1.4.1.318.1.1.10.1.2.2 | TableemConfigProbesTable | not-accessible | mandatory | A list of probes supported by the Environmental Monitor and their configurations. |
| 1.3.6.1.4.1.318.1.1.10.1.2.2.1 | RowemConfigProbesEntry | not-accessible | mandatory | The Environmental Monitor probe configurations. |
| 1.3.6.1.4.1.318.1.1.10.1.2.2.1.1 | ColumnemConfigProbeNumber | read-only | mandatory | The index into an Environmental Monitor probe entry. |
| 1.3.6.1.4.1.318.1.1.10.1.2.2.1.2 | ColumnemConfigProbeName | read-write | mandatory | A descriptive name of the probe set by the user, possibly denoting its location or purpose. |
| 1.3.6.1.4.1.318.1.1.10.1.2.2.1.3 | ColumnemConfigProbeHighTempThreshold | read-write | mandatory | The high temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.1.2.2.1.4 | ColumnemConfigProbeLowTempThreshold | read-write | mandatory | The low temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.1.2.2.1.5 | ColumnemConfigProbeTempUnits | read-only | mandatory | The temperature scale used to display the temperature thresholds of the probe, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences con… |
| 1.3.6.1.4.1.318.1.1.10.1.2.2.1.6 | ColumnemConfigProbeHighHumidThreshold | read-write | mandatory | The high humidity alarm threshold for the probe in percent relative humidity. |
| 1.3.6.1.4.1.318.1.1.10.1.2.2.1.7 | ColumnemConfigProbeLowHumidThreshold | read-write | mandatory | The low humidity alarm threshold for the probe in percent relative humidity. |
| 1.3.6.1.4.1.318.1.1.10.1.2.2.1.8 | ColumnemConfigProbeHighTempEnable | read-write | mandatory | The high temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this va… |
| 1.3.6.1.4.1.318.1.1.10.1.2.2.1.9 | ColumnemConfigProbeLowTempEnable | read-write | mandatory | The low temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this val… |
| 1.3.6.1.4.1.318.1.1.10.1.2.2.1.10 | ColumnemConfigProbeHighHumidEnable | read-write | mandatory | The high humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value… |
| 1.3.6.1.4.1.318.1.1.10.1.2.2.1.11 | ColumnemConfigProbeLowHumidEnable | read-write | mandatory | The low humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value … |
| 1.3.6.1.4.1.318.1.1.10.1.2.2.1.12 | ColumnemConfigProbeMaxTempThreshold | read-write | mandatory | The maximum temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.1.2.2.1.13 | ColumnemConfigProbeMinTempThreshold | read-write | mandatory | The minimum temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.1.2.2.1.14 | ColumnemConfigProbeMaxHumidThreshold | read-write | mandatory | The maximun humidity alarm threshold for the probe in percent relative humidity. |
| 1.3.6.1.4.1.318.1.1.10.1.2.2.1.15 | ColumnemConfigProbeMinHumidThreshold | read-write | mandatory | The minimum humidity alarm threshold for the probe in percent relative humidity. |
| 1.3.6.1.4.1.318.1.1.10.1.2.2.1.16 | ColumnemConfigProbeMaxTempEnable | read-write | mandatory | The maximum temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this… |
| 1.3.6.1.4.1.318.1.1.10.1.2.2.1.17 | ColumnemConfigProbeMinTempEnable | read-write | mandatory | The minimum temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this… |
| 1.3.6.1.4.1.318.1.1.10.1.2.2.1.18 | ColumnemConfigProbeMaxHumidEnable | read-write | mandatory | The maximum humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this va… |
| 1.3.6.1.4.1.318.1.1.10.1.2.2.1.19 | ColumnemConfigProbeMinHumidEnable | read-write | mandatory | The minimum humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this va… |
| 1.3.6.1.4.1.318.1.1.10.1.2.2.1.20 | ColumnemConfigProbeTempHysteresis | read-write | mandatory | The number of degrees beyond the temperature thresholds at which an active temperature alarm will be cleared. This configuration setting applies to all tempera… |
| 1.3.6.1.4.1.318.1.1.10.1.2.2.1.21 | ColumnemConfigProbeHumidHysteresis | read-write | mandatory | The number of percent RH points beyond the humidity thresholds at which an active humidity alarm will be cleared. This configuration setting applies to all hum… |
| 1.3.6.1.4.1.318.1.1.10.1.2.2.1.22 | ColumnemConfigProbeLocation | read-write | mandatory | A string describing the location of the probe. |
| 1.3.6.1.4.1.318.1.1.10.1.2.3 | ScalaremConfigContactsNumContacts | read-only | mandatory | The number of contacts supported by the Environmental Monitor. |
| 1.3.6.1.4.1.318.1.1.10.1.2.4 | TableemConfigContactsTable | not-accessible | mandatory | A list of contacts supported by the Environmental Monitor and their configurations. |
| 1.3.6.1.4.1.318.1.1.10.1.2.4.1 | RowemConfigContactsEntry | not-accessible | mandatory | The Environmental Monitor contact configurations. |
| 1.3.6.1.4.1.318.1.1.10.1.2.4.1.1 | ColumnemConfigContactNumber | read-only | mandatory | The index of an Environmental Monitor contact. |
| 1.3.6.1.4.1.318.1.1.10.1.2.4.1.2 | ColumnemConfigContactName | read-write | mandatory | A descriptive name for an Environmental Monitor contact set by the user, possibly denoting its location or purpose. |
| 1.3.6.1.4.1.318.1.1.10.1.2.4.1.3 | ColumnemConfigContactEnable | read-write | mandatory | An Environmental Monitor contact alarm enable/disable. No alarm will be generated if the contact is disabled(1). An alarm will be generated if the contact is e… |
| 1.3.6.1.4.1.318.1.1.10.1.2.4.1.4 | ColumnemConfigContactSeverity | read-write | mandatory | The severity of the alarm that will be triggered when the input contact is activated. The alarms can be critical(1), warning(2) or informational(3). |
| 1.3.6.1.4.1.318.1.1.10.1.2.4.1.5 | ColumnemConfigContactNormalState | read-write | mandatory | The contact state that will be considered normal, i.e. will not trigger an alarm. The states are open(1) or closed(2). |
| 1.3.6.1.4.1.318.1.1.10.1.2.4.1.6 | ColumnemConfigContactLocation | read-write | mandatory | A descriptive label for the contact denoting its location or purpose. |
| 1.3.6.1.4.1.318.1.1.10.1.3 | NodeemStatus | |||
| 1.3.6.1.4.1.318.1.1.10.1.3.1 | ScalaremStatusCommStatus | read-only | mandatory | The communication status between the agent and the Environmental Monitor. noComm(1), Communication has never been established. comm(2), Communication has been … |
| 1.3.6.1.4.1.318.1.1.10.1.3.2 | ScalaremStatusProbesNumProbes | read-only | mandatory | The number of available probes on the Environmental Monitor. |
| 1.3.6.1.4.1.318.1.1.10.1.3.3 | TableemStatusProbesTable | not-accessible | mandatory | A list of probes supported by the Environmental Monitor and their status. |
| 1.3.6.1.4.1.318.1.1.10.1.3.3.1 | RowemStatusProbesEntry | not-accessible | mandatory | The status of the probe. |
| 1.3.6.1.4.1.318.1.1.10.1.3.3.1.1 | ColumnemStatusProbeNumber | read-only | mandatory | The index of the probe. |
| 1.3.6.1.4.1.318.1.1.10.1.3.3.1.2 | ColumnemStatusProbeName | read-only | mandatory | A descriptive name for the probe set by the user, possibly denoting its location or purpose. |
| 1.3.6.1.4.1.318.1.1.10.1.3.3.1.3 | ColumnemStatusProbeStatus | read-only | mandatory | The connected status of the probe, either disconnected(1) or connected(2). |
| 1.3.6.1.4.1.318.1.1.10.1.3.3.1.4 | ColumnemStatusProbeCurrentTemp | read-only | mandatory | The current temperature reading from the probe displayed in the units shown in the 'emStatusProbeTempUnits' OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.1.3.3.1.5 | ColumnemStatusProbeTempUnits | read-only | mandatory | The temperature scale used to display the temperature thresholds of the probe, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences con… |
| 1.3.6.1.4.1.318.1.1.10.1.3.3.1.6 | ColumnemStatusProbeCurrentHumid | read-only | mandatory | The current humidity reading from the probe in percent relative humidity. |
| 1.3.6.1.4.1.318.1.1.10.1.3.3.1.7 | ColumnemStatusProbeHighTempViolation | read-only | mandatory | The high temperature violation status of the probe temperature reading. This OID will show a highTempViolation(2) if the current temperature reading shown in t… |
| 1.3.6.1.4.1.318.1.1.10.1.3.3.1.8 | ColumnemStatusProbeLowTempViolation | read-only | mandatory | The high temperature violation status of the probe temperature reading. This OID will show a lowTempViolation(2) if the current temperature reading shown in th… |
| 1.3.6.1.4.1.318.1.1.10.1.3.3.1.9 | ColumnemStatusProbeHighHumidViolation | read-only | mandatory | The high humidity violation status of the probe humidity reading. This OID will show a highTempViolation(2) if the current humidity reading shown in the 'emSta… |
| 1.3.6.1.4.1.318.1.1.10.1.3.3.1.10 | ColumnemStatusProbeLowHumidViolation | read-only | mandatory | The low humidity violation status of the probe humidity reading. This OID will show a lowTempViolation(2) if the current humidity reading shown in the 'emStatu… |
| 1.3.6.1.4.1.318.1.1.10.1.3.3.1.11 | ColumnemStatusProbeMaxTempViolation | read-only | mandatory | The max temperature violation status of the probe temperature reading. This OID will show a maxTempViolation(2) if the current temperature reading shown in the… |
| 1.3.6.1.4.1.318.1.1.10.1.3.3.1.12 | ColumnemStatusProbeMinTempViolation | read-only | mandatory | The minimum temperature violation status of the probe temperature reading. This OID will show a minTempViolation(2) if the current temperature reading shown in… |
| 1.3.6.1.4.1.318.1.1.10.1.3.3.1.13 | ColumnemStatusProbeMaxHumidViolation | read-only | mandatory | The maximum humidity violation status of the probe humidity reading. This OID will show a maxTempViolation(2) if the current humidity reading shown in the 'emS… |
| 1.3.6.1.4.1.318.1.1.10.1.3.3.1.14 | ColumnemStatusProbeMinHumidViolation | read-only | mandatory | The minimum humidity violation status of the probe humidity reading. This OID will show a minTempViolation(2) if the current humidity reading shown in the 'emS… |
| 1.3.6.1.4.1.318.1.1.10.1.3.4 | ScalaremStatusContactsNumContacts | read-only | mandatory | The number of contacts supported by the Environmental Monitor. |
| 1.3.6.1.4.1.318.1.1.10.1.3.5 | TableemStatusContactsTable | not-accessible | mandatory | A list of contacts supported by the Environmental Monitor and their status. |
| 1.3.6.1.4.1.318.1.1.10.1.3.5.1 | RowemStatusContactsEntry | not-accessible | mandatory | The status of the contact. |
| 1.3.6.1.4.1.318.1.1.10.1.3.5.1.1 | ColumnemStatusContactNumber | read-only | mandatory | The index of the Environmental Monitor contact. |
| 1.3.6.1.4.1.318.1.1.10.1.3.5.1.2 | ColumnemStatusContactName | read-only | mandatory | A descriptive name for the Environmental Monitor contact set by the user, possibly denoting its location or purpose. |
| 1.3.6.1.4.1.318.1.1.10.1.3.5.1.3 | ColumnemStatusContactStatus | read-only | mandatory | The status of the Environmental Monitor contact. The status will show noFault(1) if the contact is in the normal state and the 'emConfigContactEnable' OID is e… |
| 1.3.6.1.4.1.318.1.1.10.2 | Nodeintegrated | |||
| 1.3.6.1.4.1.318.1.1.10.2.1 | NodeiemIdent | |||
| 1.3.6.1.4.1.318.1.1.10.2.1.1 | ScalariemIdentHardwareRevision | read-only | mandatory | The hardware revision of the Integrated Environmental Monitor. |
| 1.3.6.1.4.1.318.1.1.10.2.2 | NodeiemConfig | |||
| 1.3.6.1.4.1.318.1.1.10.2.2.1 | ScalariemConfigProbesNumProbes | read-only | mandatory | The number of temperature and humidity probes available. |
| 1.3.6.1.4.1.318.1.1.10.2.2.2 | TableiemConfigProbesTable | not-accessible | mandatory | A list of probes supported by the Environmental Monitor and their configurations. |
| 1.3.6.1.4.1.318.1.1.10.2.2.2.1 | RowiemConfigProbesEntry | not-accessible | mandatory | The Environmental Monitor probe configurations. |
| 1.3.6.1.4.1.318.1.1.10.2.2.2.1.1 | ColumniemConfigProbeNumber | read-only | mandatory | The index to a Environmental Monitor probe entry. |
| 1.3.6.1.4.1.318.1.1.10.2.2.2.1.2 | ColumniemConfigProbeName | read-write | mandatory | A descriptive name for the probe set by the user, possibly denoting its location or purpose. |
| 1.3.6.1.4.1.318.1.1.10.2.2.2.1.3 | ColumniemConfigProbeHighTempThreshold | read-write | mandatory | The high temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.2.2.2.1.4 | ColumniemConfigProbeLowTempThreshold | read-write | mandatory | The low temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.2.2.2.1.5 | ColumniemConfigProbeTempUnits | read-only | mandatory | The temperature scale used to display the temperature thresholds of the probe, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences con… |
| 1.3.6.1.4.1.318.1.1.10.2.2.2.1.6 | ColumniemConfigProbeHighHumidThreshold | read-write | mandatory | The high humidity alarm threshold for the probe in percent relative humidity. |
| 1.3.6.1.4.1.318.1.1.10.2.2.2.1.7 | ColumniemConfigProbeLowHumidThreshold | read-write | mandatory | The low humidity alarm threshold for the probe in percent relative humidity. |
| 1.3.6.1.4.1.318.1.1.10.2.2.2.1.8 | ColumniemConfigProbeHighTempEnable | read-write | mandatory | The high temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this va… |
| 1.3.6.1.4.1.318.1.1.10.2.2.2.1.9 | ColumniemConfigProbeLowTempEnable | read-write | mandatory | The low temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this val… |
| 1.3.6.1.4.1.318.1.1.10.2.2.2.1.10 | ColumniemConfigProbeHighHumidEnable | read-write | mandatory | The high humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value… |
| 1.3.6.1.4.1.318.1.1.10.2.2.2.1.11 | ColumniemConfigProbeLowHumidEnable | read-write | mandatory | The low humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value … |
| 1.3.6.1.4.1.318.1.1.10.2.2.2.1.12 | ColumniemConfigProbeMaxTempThreshold | read-write | mandatory | The maximun temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.2.2.2.1.13 | ColumniemConfigProbeMinTempThreshold | read-write | mandatory | The minimun temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.2.2.2.1.14 | ColumniemConfigProbeMaxHumidThreshold | read-write | mandatory | The maximum humidity alarm threshold for the probe in percent relative humidity. |
| 1.3.6.1.4.1.318.1.1.10.2.2.2.1.15 | ColumniemConfigProbeMinHumidThreshold | read-write | mandatory | The minimum humidity alarm threshold for the probe in percent relative humidity. |
| 1.3.6.1.4.1.318.1.1.10.2.2.2.1.16 | ColumniemConfigProbeMaxTempEnable | read-write | mandatory | The maximum temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this… |
| 1.3.6.1.4.1.318.1.1.10.2.2.2.1.17 | ColumniemConfigProbeMinTempEnable | read-write | mandatory | The low temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this val… |
| 1.3.6.1.4.1.318.1.1.10.2.2.2.1.18 | ColumniemConfigProbeMaxHumidEnable | read-write | mandatory | The maximum humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this va… |
| 1.3.6.1.4.1.318.1.1.10.2.2.2.1.19 | ColumniemConfigProbeMinHumidEnable | read-write | mandatory | The minimum humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this va… |
| 1.3.6.1.4.1.318.1.1.10.2.2.2.1.20 | ColumniemConfigProbeTempHysteresis | read-write | mandatory | The number of degrees beyond the temperature thresholds at which an active temperature alarm will be cleared. This configuration setting applies to all tempera… |
| 1.3.6.1.4.1.318.1.1.10.2.2.2.1.21 | ColumniemConfigProbeHumidHysteresis | read-write | mandatory | The number of percent RH points beyond the humidity thresholds at which an active humidity alarm will be cleared. This configuration setting applies to all hum… |
| 1.3.6.1.4.1.318.1.1.10.2.2.2.1.22 | ColumniemConfigProbeLocation | read-write | mandatory | A string describing the location of the probe. |
| 1.3.6.1.4.1.318.1.1.10.2.2.3 | ScalariemConfigContactsNumContacts | read-only | mandatory | The number of contacts available on the Environmental Monitor. |
| 1.3.6.1.4.1.318.1.1.10.2.2.4 | TableiemConfigContactsTable | not-accessible | mandatory | A list of contacts supported by the Environmental Monitor and their configurations. |
| 1.3.6.1.4.1.318.1.1.10.2.2.4.1 | RowiemConfigContactsEntry | not-accessible | mandatory | The Environmental Monitor contact configurations. |
| 1.3.6.1.4.1.318.1.1.10.2.2.4.1.1 | ColumniemConfigContactNumber | read-only | mandatory | The index of an Environmental Monitor contact. |
| 1.3.6.1.4.1.318.1.1.10.2.2.4.1.2 | ColumniemConfigContactName | read-write | mandatory | A descriptive name for the Environmental Monitor contact set by the user, possibly denoting its location or purpose. |
| 1.3.6.1.4.1.318.1.1.10.2.2.4.1.3 | ColumniemConfigContactEnable | read-write | mandatory | An Environmental Monitor contact alarm enable/disable. |
| 1.3.6.1.4.1.318.1.1.10.2.2.4.1.4 | ColumniemConfigContactSeverity | read-write | mandatory | The severtity of the alarm that will be triggered when the input contact is activated. The alarms can be critical(1), warning(2) or informational(3). NOTE: inf… |
| 1.3.6.1.4.1.318.1.1.10.2.2.4.1.5 | ColumniemConfigContactNormalState | read-write | mandatory | The contact state that will be considered normal, i.e. will not trigger an alarm. The states are open(1) or closed(2). |
| 1.3.6.1.4.1.318.1.1.10.2.2.4.1.6 | ColumniemConfigContactLocation | read-write | mandatory | A descriptive label for the contact denoting its location or purpose. |
| 1.3.6.1.4.1.318.1.1.10.2.2.5 | ScalariemConfigConfigRelaysNumRelays | read-only | mandatory | The number of output relays supported by the Environmental Monitor. |
| 1.3.6.1.4.1.318.1.1.10.2.2.6 | TableiemConfigRelaysTable | not-accessible | mandatory | A list of output relays supported by the Environmental Monitor and their configurations. |
| 1.3.6.1.4.1.318.1.1.10.2.2.6.1 | RowiemConfigRelaysEntry | not-accessible | mandatory | The Environmental Monitor output relay configurations. |
| 1.3.6.1.4.1.318.1.1.10.2.2.6.1.1 | ColumniemConfigRelayNumber | read-only | mandatory | The index of an Environmental Monitor output relay. |
| 1.3.6.1.4.1.318.1.1.10.2.2.6.1.2 | ColumniemConfigRelayName | read-write | mandatory | A descriptive name of an Environmental Monitor output relay, set by the user, describing its location or purpose. |
| 1.3.6.1.4.1.318.1.1.10.2.2.6.1.3 | ColumniemConfigRelayNormalState | read-write | mandatory | The normal state (non-fault state) of an Environmental Monitor output relay, either open(1) or closed(2). |
| 1.3.6.1.4.1.318.1.1.10.2.2.6.1.4 | ColumniemConfigRelayFaultCondition | read-write | mandatory | The fault condition used to activate the output relay. |
| 1.3.6.1.4.1.318.1.1.10.2.3 | NodeiemStatus | |||
| 1.3.6.1.4.1.318.1.1.10.2.3.1 | ScalariemStatusProbesNumProbes | read-only | mandatory | The number of available probes on the Environmental Monitor. |
| 1.3.6.1.4.1.318.1.1.10.2.3.2 | TableiemStatusProbesTable | not-accessible | mandatory | A list of probes supported by the Environmental Monitor and their status. |
| 1.3.6.1.4.1.318.1.1.10.2.3.2.1 | RowiemStatusProbesEntry | not-accessible | mandatory | The status of the probe. |
| 1.3.6.1.4.1.318.1.1.10.2.3.2.1.1 | ColumniemStatusProbeNumber | read-only | mandatory | The index of the probe. |
| 1.3.6.1.4.1.318.1.1.10.2.3.2.1.2 | ColumniemStatusProbeName | read-only | mandatory | A descriptive name for the probe set by the user. |
| 1.3.6.1.4.1.318.1.1.10.2.3.2.1.3 | ColumniemStatusProbeStatus | read-only | mandatory | The connected status of the probe, either disconnected(1) or connected(2). |
| 1.3.6.1.4.1.318.1.1.10.2.3.2.1.4 | ColumniemStatusProbeCurrentTemp | read-only | mandatory | The current temperature reading from the probe displayed in the units shown in the 'iemStatusProbeTempUnits' OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.2.3.2.1.5 | ColumniemStatusProbeTempUnits | read-only | mandatory | The temperature scale used to display the temperature thresholds of the probe, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences con… |
| 1.3.6.1.4.1.318.1.1.10.2.3.2.1.6 | ColumniemStatusProbeCurrentHumid | read-only | mandatory | The current humidity reading from the probe in percent relative humidity. |
| 1.3.6.1.4.1.318.1.1.10.2.3.2.1.7 | ColumniemStatusProbeHighTempViolation | read-only | mandatory | The high temperature violation status of the probe temperature reading. This OID will show a highTempViolation(2) if the current temperature reading shown in t… |
| 1.3.6.1.4.1.318.1.1.10.2.3.2.1.8 | ColumniemStatusProbeLowTempViolation | read-only | mandatory | The high temperature violation status of the probe temperature reading. This OID will show a lowTempViolation(2) if the current temperature reading shown in th… |
| 1.3.6.1.4.1.318.1.1.10.2.3.2.1.9 | ColumniemStatusProbeHighHumidViolation | read-only | mandatory | The high humidity violation status of the probe humidity reading. This OID will show a highTempViolation(2) if the current humidity reading shown in the 'iemSt… |
| 1.3.6.1.4.1.318.1.1.10.2.3.2.1.10 | ColumniemStatusProbeLowHumidViolation | read-only | mandatory | The low humidity violation status of the probe humidity reading. This OID will show a lowTempViolation(2) if the current humidity reading shown in the 'iemStat… |
| 1.3.6.1.4.1.318.1.1.10.2.3.2.1.11 | ColumniemStatusProbeMaxTempViolation | read-only | mandatory | The max temperature violation status of the probe temperature reading. This OID will show a maxTempViolation(2) if the current temperature reading shown in the… |
| 1.3.6.1.4.1.318.1.1.10.2.3.2.1.12 | ColumniemStatusProbeMinTempViolation | read-only | mandatory | The minimum temperature violation status of the probe temperature reading. This OID will show a minTempViolation(2) if the current temperature reading shown in… |
| 1.3.6.1.4.1.318.1.1.10.2.3.2.1.13 | ColumniemStatusProbeMaxHumidViolation | read-only | mandatory | The maximum humidity violation status of the probe humidity reading. This OID will show a maxTempViolation(2) if the current humidity reading shown in the 'iem… |
| 1.3.6.1.4.1.318.1.1.10.2.3.2.1.14 | ColumniemStatusProbeMinHumidViolation | read-only | mandatory | The minimum humidity violation status of the probe humidity reading. This OID will show a minTempViolation(2) if the current humidity reading shown in the 'iem… |
| 1.3.6.1.4.1.318.1.1.10.2.3.2.1.15 | ColumniemStatusProbeLocation | read-only | mandatory | A descriptive location for the probe set by the user. |
| 1.3.6.1.4.1.318.1.1.10.2.3.3 | ScalariemStatusContactsNumContacts | read-only | mandatory | The number of contacts supported on the Environmental Monitor. |
| 1.3.6.1.4.1.318.1.1.10.2.3.4 | TableiemStatusContactsTable | not-accessible | mandatory | A list of contacts supported by the Environmental Monitor and their status. |
| 1.3.6.1.4.1.318.1.1.10.2.3.4.1 | RowiemStatusContactsEntry | not-accessible | mandatory | The status of the contact. |
| 1.3.6.1.4.1.318.1.1.10.2.3.4.1.1 | ColumniemStatusContactNumber | read-only | mandatory | The index of the Environmental Monitor contact. |
| 1.3.6.1.4.1.318.1.1.10.2.3.4.1.2 | ColumniemStatusContactName | read-only | mandatory | A descriptive name for the Environmental Monitor contact set by the user, denoting its location or purpose. |
| 1.3.6.1.4.1.318.1.1.10.2.3.4.1.3 | ColumniemStatusContactStatus | read-only | mandatory | The status of the Environmental Monitor contact. The status will show noFault(1) if the contact is in the normal state and the 'iemConfigContactEnable' OID is … |
| 1.3.6.1.4.1.318.1.1.10.2.3.6 | ScalariemStatusRelaysNumRelays | read-only | mandatory | The number of output relays supported on the Environmental Monitor. |
| 1.3.6.1.4.1.318.1.1.10.2.3.7 | TableiemStatusRelaysTable | not-accessible | mandatory | A list of output relays supported by the Environmental Monitor and their status. |
| 1.3.6.1.4.1.318.1.1.10.2.3.7.1 | RowiemStatusRelaysEntry | not-accessible | mandatory | The status of the relay. |
| 1.3.6.1.4.1.318.1.1.10.2.3.7.1.1 | ColumniemStatusRelayNumber | read-only | mandatory | The index of the output relay. |
| 1.3.6.1.4.1.318.1.1.10.2.3.7.1.2 | ColumniemStatusRelayName | read-only | mandatory | A descriptive name for the output relay set by the user, denoting its location or purpose. |
| 1.3.6.1.4.1.318.1.1.10.2.3.7.1.3 | ColumniemStatusRelayStatus | read-only | mandatory | The status of the output relay, either faultState(1) or normalState(2). |
| 1.3.6.1.4.1.318.1.1.10.3 | NodeenvMgtSystem | |||
| 1.3.6.1.4.1.318.1.1.10.3.1 | NodeemsIdent | |||
| 1.3.6.1.4.1.318.1.1.10.3.1.1 | ScalaremsIdentEMSName | read-only | mandatory | A character string identifying the device. |
| 1.3.6.1.4.1.318.1.1.10.3.1.2 | ScalaremsIdentProductNumber | read-only | mandatory | A character string identifying the model number of the device. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.10.3.1.3 | ScalaremsIdentFirmwareRev | read-only | mandatory | The firmware revision of the device. |
| 1.3.6.1.4.1.318.1.1.10.3.1.4 | ScalaremsIdentHardwareRev | read-only | mandatory | The hardware revision of the device. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.10.3.1.5 | ScalaremsIdentDateOfManufacture | read-only | mandatory | The date when the device was manufactured in mm/dd/yyyy format. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.10.3.1.6 | ScalaremsIdentSerialNumber | read-only | mandatory | A character string identifying the serial number of the device. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.10.3.2 | NodeemsOutputRelayControl | |||
| 1.3.6.1.4.1.318.1.1.10.3.2.1 | TableemsOutputRelayControlTable | not-accessible | mandatory | Allows for control of individual output relays. The number of entries is contained in the emsStatusOutputRelayCount OID. |
| 1.3.6.1.4.1.318.1.1.10.3.2.1.1 | RowemsOutputRelayControlEntry | not-accessible | mandatory | The output relays to control. |
| 1.3.6.1.4.1.318.1.1.10.3.2.1.1.1 | ColumnemsOutputRelayControlOutputRelayIndex | read-only | mandatory | The index to the output relay entry. |
| 1.3.6.1.4.1.318.1.1.10.3.2.1.1.2 | ColumnemsOutputRelayControlOutputRelayName | read-only | mandatory | The name of the output relay. This OID is provided for informational purposes only. |
| 1.3.6.1.4.1.318.1.1.10.3.2.1.1.3 | ColumnemsOutputRelayControlOutputRelayCommand | read-write | mandatory | Getting this variable will return the output relay state. If the output relay is closed, the immediateCloseEMS (1) value will be returned. If the output relay … |
| 1.3.6.1.4.1.318.1.1.10.3.3 | NodeemsOutletControl | |||
| 1.3.6.1.4.1.318.1.1.10.3.3.1 | TableemsOutletControlTable | not-accessible | mandatory | Allows for control of individual outlet switches. The number of entries is contained in the emsStatusOutletCount OID. |
| 1.3.6.1.4.1.318.1.1.10.3.3.1.1 | RowemsOutletControlEntry | not-accessible | mandatory | The outlets to control. |
| 1.3.6.1.4.1.318.1.1.10.3.3.1.1.1 | ColumnemsOutletControlOutletIndex | read-only | mandatory | The index to the outlet entry. |
| 1.3.6.1.4.1.318.1.1.10.3.3.1.1.2 | ColumnemsOutletControlOutletName | read-only | mandatory | The name of the outlet. This OID is provided for informational purposes only. |
| 1.3.6.1.4.1.318.1.1.10.3.3.1.1.3 | ColumnemsOutletControlOutletCommand | read-write | mandatory | Getting this variable will return the outlet state. If the outlet is on, the immediateOnEMS (1) value will be returned. If the outlet is off, the immediateOffE… |
| 1.3.6.1.4.1.318.1.1.10.3.4 | NodeemsSensorControl | |||
| 1.3.6.1.4.1.318.1.1.10.3.4.1 | TableemsSensorControlTable | not-accessible | mandatory | Allows for control/reset of individual sensors. The number of entries is contained in the emsStatusSensorCount OID. |
| 1.3.6.1.4.1.318.1.1.10.3.4.1.1 | RowemsSensorControlEntry | not-accessible | mandatory | The sensors to control/reset. |
| 1.3.6.1.4.1.318.1.1.10.3.4.1.1.1 | ColumnemsSensorControlSensorIndex | read-only | mandatory | The index to the sensor entry. |
| 1.3.6.1.4.1.318.1.1.10.3.4.1.1.2 | ColumnemsSensorControlSensorSystemName | read-only | mandatory | The system name of the sensor. This describes the hardware system intent of this sensor. |
| 1.3.6.1.4.1.318.1.1.10.3.4.1.1.3 | ColumnemsSensorControlSensorUserName | read-only | mandatory | The name of the sensor as given by the system user. |
| 1.3.6.1.4.1.318.1.1.10.3.4.1.1.4 | ColumnemsSensorControlSensorCommand | read-write | mandatory | Getting this variable will return noCommandEMS(1). Setting this variable to resetCommandEMS(2) will issue a reset command to the sensor. Some sensors cannot be… |
| 1.3.6.1.4.1.318.1.1.10.3.5 | NodeemsAlarmDeviceControl | |||
| 1.3.6.1.4.1.318.1.1.10.3.5.1 | TableemsAlarmDeviceControlTable | not-accessible | mandatory | Allows for control of individual alarm devices. Note: Some alarm devices are not controllable. The number of entries is contained in the emsStatusAlarmDeviceCo… |
| 1.3.6.1.4.1.318.1.1.10.3.5.1.1 | RowemsAlarmDeviceControlEntry | not-accessible | mandatory | The alarm devices to control. |
| 1.3.6.1.4.1.318.1.1.10.3.5.1.1.1 | ColumnemsAlarmDeviceControlDeviceIndex | read-only | mandatory | The index to the alarm device entry. |
| 1.3.6.1.4.1.318.1.1.10.3.5.1.1.2 | ColumnemsAlarmDeviceControlDeviceName | read-only | mandatory | The name of the alarm device. This OID is provided for informational purposes only. |
| 1.3.6.1.4.1.318.1.1.10.3.5.1.1.3 | ColumnemsAlarmDeviceControlDeviceCommand | read-write | mandatory | Getting this variable will return the device state. If the device is active, the alarmDeviceOnEMS (1) value will be returned. If the device is inactive, the al… |
| 1.3.6.1.4.1.318.1.1.10.3.6 | NodeemsConfig | |||
| 1.3.6.1.4.1.318.1.1.10.3.6.1 | ScalaremsConfigName | read-write | mandatory | The name of the device. |
| 1.3.6.1.4.1.318.1.1.10.3.6.2 | ScalaremsConfigCheckLogLight | read-write | mandatory | The setting of this OID determines the level of event that will trigger the check-log light on the EMS. This is not available on the EMU2. lightDisabled (1) di… |
| 1.3.6.1.4.1.318.1.1.10.3.7 | NodeemsProbeConfig | |||
| 1.3.6.1.4.1.318.1.1.10.3.7.1 | TableemsProbeConfigTable | not-accessible | mandatory | Allows for configuration of individual probes. The number of entries is contained in the emsStatusProbeCount OID. |
| 1.3.6.1.4.1.318.1.1.10.3.7.1.1 | RowemsProbeConfigEntry | not-accessible | mandatory | The probes to configure. |
| 1.3.6.1.4.1.318.1.1.10.3.7.1.1.1 | ColumnemsProbeConfigProbeIndex | read-only | mandatory | The index to the probe entry. |
| 1.3.6.1.4.1.318.1.1.10.3.7.1.1.2 | ColumnemsProbeConfigProbeName | read-write | mandatory | The name of the probe. |
| 1.3.6.1.4.1.318.1.1.10.3.7.1.1.3 | ColumnemsProbeConfigProbeHighTempThresh | read-write | mandatory | Probe high temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Cels… |
| 1.3.6.1.4.1.318.1.1.10.3.7.1.1.4 | ColumnemsProbeConfigProbeLowTempThresh | read-write | mandatory | Probe low temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsi… |
| 1.3.6.1.4.1.318.1.1.10.3.7.1.1.5 | ColumnemsProbeConfigProbeHighHumidityThresh | read-write | mandatory | Probe high humidity threshold. Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.3.7.1.1.6 | ColumnemsProbeConfigProbeLowHumidityThresh | read-write | mandatory | Probe low humidity threshold. Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.3.7.1.1.7 | ColumnemsProbeConfigProbeMaxTempThresh | read-write | mandatory | Probe maximum temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (C… |
| 1.3.6.1.4.1.318.1.1.10.3.7.1.1.8 | ColumnemsProbeConfigProbeMinTempThresh | read-write | mandatory | Probe minimum temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (C… |
| 1.3.6.1.4.1.318.1.1.10.3.7.1.1.9 | ColumnemsProbeConfigProbeDeltaTemp | read-write | mandatory | Probe delta temperature. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fa… |
| 1.3.6.1.4.1.318.1.1.10.3.7.1.1.10 | ColumnemsProbeConfigProbeMaxHumidityThresh | read-write | mandatory | Probe maximum humidity threshold. Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.3.7.1.1.11 | ColumnemsProbeConfigProbeMinHumidityThresh | read-write | mandatory | Probe minimum humidity threshold. Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.3.7.1.1.12 | ColumnemsProbeConfigProbeDeltaHumidity | read-write | mandatory | Probe delta humidity. Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.3.7.1.1.13 | ColumnemsProbeConfigProbeSTIncTempVariance | read-write | mandatory | Probe short-term increasing temperature variance used for rate of change alarms. Values are represented in whole number degrees. Units are displayed in the sca… |
| 1.3.6.1.4.1.318.1.1.10.3.7.1.1.14 | ColumnemsProbeConfigProbeSTIncTempTime | read-write | mandatory | Probe short-term increasing temperature time used for rate of change alarms. Values are represented in whole number minutes. |
| 1.3.6.1.4.1.318.1.1.10.3.7.1.1.15 | ColumnemsProbeConfigProbeSTDecTempVariance | read-write | mandatory | Probe short-term decreasing temperature variance used for rate of change alarms. Values are represented in whole number degrees. Units are displayed in the sca… |
| 1.3.6.1.4.1.318.1.1.10.3.7.1.1.16 | ColumnemsProbeConfigProbeSTDecTempTime | read-write | mandatory | Probe short-term decreasing temperature time used for rate of change alarms. Values are represented in whole number minutes. |
| 1.3.6.1.4.1.318.1.1.10.3.7.1.1.17 | ColumnemsProbeConfigProbeLTIncTempVariance | read-write | mandatory | Probe long-term increasing temperature variance used for rate of change alarms. Values are represented in whole number degrees. Units are displayed in the scal… |
| 1.3.6.1.4.1.318.1.1.10.3.7.1.1.18 | ColumnemsProbeConfigProbeLTIncTempTime | read-write | mandatory | Probe long-term increasing temperature time used for rate of change alarms. Values are represented in whole number hours. |
| 1.3.6.1.4.1.318.1.1.10.3.7.1.1.19 | ColumnemsProbeConfigProbeLTDecTempVariance | read-write | mandatory | Probe long-term decreasing temperature variance used for rate of change alarms. Values are represented in whole number degrees. Units are displayed in the scal… |
| 1.3.6.1.4.1.318.1.1.10.3.7.1.1.20 | ColumnemsProbeConfigProbeLTDecTempTime | read-write | mandatory | Probe long-term decreasing temperature time used for rate of change alarms. Values are represented in whole number hours. |
| 1.3.6.1.4.1.318.1.1.10.3.8 | NodeemsInputContactConfig | |||
| 1.3.6.1.4.1.318.1.1.10.3.8.1 | TableemsInputContactConfigTable | not-accessible | mandatory | Allows for configuration of individual input contacts. The number of entries is contained in the emsStatusInputContactCount OID. |
| 1.3.6.1.4.1.318.1.1.10.3.8.1.1 | RowemsInputContactConfigEntry | not-accessible | mandatory | The input contacts to configure. |
| 1.3.6.1.4.1.318.1.1.10.3.8.1.1.1 | ColumnemsInputContactConfigInputContactIndex | read-only | mandatory | The index to the input contact entry. |
| 1.3.6.1.4.1.318.1.1.10.3.8.1.1.2 | ColumnemsInputContactConfigInputContactName | read-write | mandatory | The name of the input contact. |
| 1.3.6.1.4.1.318.1.1.10.3.8.1.1.3 | ColumnemsInputContactConfigInputContactNormalState | read-write | mandatory | Getting this variable will return the normal state of the input contact. If the normal state is closed, the normallyClosedEMS (1) value will be returned. If th… |
| 1.3.6.1.4.1.318.1.1.10.3.9 | NodeemsOutputRelayConfig | |||
| 1.3.6.1.4.1.318.1.1.10.3.9.1 | TableemsOutputRelayConfigTable | not-accessible | mandatory | Allows for configuration of individual output relays. The number of entries is contained in the emsStatusOutputRelayCount OID. |
| 1.3.6.1.4.1.318.1.1.10.3.9.1.1 | RowemsOutputRelayConfigEntry | not-accessible | mandatory | The output relays to configure. |
| 1.3.6.1.4.1.318.1.1.10.3.9.1.1.1 | ColumnemsOutputRelayConfigOutputRelayIndex | read-only | mandatory | The index to the output relay entry. |
| 1.3.6.1.4.1.318.1.1.10.3.9.1.1.2 | ColumnemsOutputRelayConfigOutputRelayName | read-write | mandatory | The name of the output relay. |
| 1.3.6.1.4.1.318.1.1.10.3.9.1.1.3 | ColumnemsOutputRelayConfigOutputRelayNormalState | read-write | mandatory | Getting this variable will return the normal state of the output relay. If the normal state is closed, the normallyClosedEMS (1) value will be returned. If the… |
| 1.3.6.1.4.1.318.1.1.10.3.10 | NodeemsOutletConfig | |||
| 1.3.6.1.4.1.318.1.1.10.3.10.1 | TableemsOutletConfigTable | not-accessible | mandatory | Allows for configuration of individual outlets. The number of entries is contained in the emsStatusOutletCount OID. |
| 1.3.6.1.4.1.318.1.1.10.3.10.1.1 | RowemsOutletConfigEntry | not-accessible | mandatory | The outlets to configure. |
| 1.3.6.1.4.1.318.1.1.10.3.10.1.1.1 | ColumnemsOutletConfigOutletIndex | read-only | mandatory | The index to the outlet entry. |
| 1.3.6.1.4.1.318.1.1.10.3.10.1.1.2 | ColumnemsOutletConfigOutletName | read-write | mandatory | The name of the outlet. |
| 1.3.6.1.4.1.318.1.1.10.3.10.1.1.3 | ColumnemsOutletConfigOutletNormalState | read-write | mandatory | Getting this variable will return the normal state of the outlet. If the normal state is on, the normallyOnEMS (1) value will be returned. If the normal state … |
| 1.3.6.1.4.1.318.1.1.10.3.11 | NodeemsSensorConfig | |||
| 1.3.6.1.4.1.318.1.1.10.3.11.1 | TableemsSensorConfigTable | not-accessible | mandatory | Allows for configuration of individual sensors. The number of entries is contained in the emsStatusSensorCount OID. |
| 1.3.6.1.4.1.318.1.1.10.3.11.1.1 | RowemsSensorConfigEntry | not-accessible | mandatory | The sensors to configure. |
| 1.3.6.1.4.1.318.1.1.10.3.11.1.1.1 | ColumnemsSensorConfigSensorIndex | read-only | mandatory | The index to the sensor entry. |
| 1.3.6.1.4.1.318.1.1.10.3.11.1.1.2 | ColumnemsSensorConfigSensorSystemName | read-only | mandatory | The system name of the sensor. This describes the hardware system intent of this sensor. |
| 1.3.6.1.4.1.318.1.1.10.3.11.1.1.3 | ColumnemsSensorConfigSensorUserName | read-write | mandatory | The name of the sensor as given by the system user. |
| 1.3.6.1.4.1.318.1.1.10.3.11.1.1.4 | ColumnemsSensorConfigSensorNormalState | read-write | mandatory | Getting this variable will return the normal state of the sensor. If the normal state is closed, the normallyClosedEMS (1) value will be returned. If the norma… |
| 1.3.6.1.4.1.318.1.1.10.3.11.1.1.5 | ColumnemsSensorConfigSensorAlarmDelay | read-write | mandatory | The delay (in seconds) after a sensor detects an alarm condition before the condition is reported. |
| 1.3.6.1.4.1.318.1.1.10.3.12 | NodeemsStatus | |||
| 1.3.6.1.4.1.318.1.1.10.3.12.1 | ScalaremsStatusEMSName | read-only | mandatory | A character string identifying the device. |
| 1.3.6.1.4.1.318.1.1.10.3.12.2 | ScalaremsStatusCommStatus | read-only | mandatory | The communication status between the agent and the device. noComm(1), Communication has never been established. comm(2), Communication has been established. co… |
| 1.3.6.1.4.1.318.1.1.10.3.12.3 | ScalaremsStatusProbeCount | read-only | mandatory | The total number of T/H probes (both local and remote) that is supported by this device. |
| 1.3.6.1.4.1.318.1.1.10.3.12.4 | ScalaremsStatusInputContactCount | read-only | mandatory | The total number of Input Contacts that is supported by this device. |
| 1.3.6.1.4.1.318.1.1.10.3.12.5 | ScalaremsStatusOutputRelayCount | read-only | mandatory | The total number of Output Relays that is supported by this device. |
| 1.3.6.1.4.1.318.1.1.10.3.12.6 | ScalaremsStatusOutletCount | read-only | mandatory | The total number of AC Outlets that is supported by this device. |
| 1.3.6.1.4.1.318.1.1.10.3.12.7 | ScalaremsStatusSensorCount | read-only | mandatory | The total number of Sensors that is supported by this device. |
| 1.3.6.1.4.1.318.1.1.10.3.12.8 | ScalaremsStatusAlinkAruDeviceCount | read-only | mandatory | The total number of remote Aru's supported by this device. |
| 1.3.6.1.4.1.318.1.1.10.3.12.9 | ScalaremsStatusAlinkProbeDeviceCount | read-only | mandatory | The total number of remote T/H probes supported by this device. |
| 1.3.6.1.4.1.318.1.1.10.3.12.10 | ScalaremsStatusAlarmDeviceCount | read-only | mandatory | The number of alarm devices supported by this device. |
| 1.3.6.1.4.1.318.1.1.10.3.12.11 | ScalaremsStatusSysTempUnits | read-only | mandatory | The temperature scale used to display the temperature in the system, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration… |
| 1.3.6.1.4.1.318.1.1.10.3.12.12 | ScalaremsStatusCheckLogLight | read-only | mandatory | The status of the check-log light on the device. For the EMU2, this will always indicate lightOff(1). lightOff (1) indicates the light is off (no new log entri… |
| 1.3.6.1.4.1.318.1.1.10.3.12.13 | ScalaremsStatusHardwareStatus | read-only | mandatory | The status of the EMS hardware. This integer should be interpreted as a bit map, with each bit representing the presence or absence of a specific hardware erro… |
| 1.3.6.1.4.1.318.1.1.10.3.13 | NodeemsProbeStatus | |||
| 1.3.6.1.4.1.318.1.1.10.3.13.1 | TableemsProbeStatusTable | not-accessible | mandatory | Allows for access of individual probes. The number of entries is contained in the emsStatusProbeCount OID. |
| 1.3.6.1.4.1.318.1.1.10.3.13.1.1 | RowemsProbeStatusEntry | not-accessible | mandatory | The probes to access. |
| 1.3.6.1.4.1.318.1.1.10.3.13.1.1.1 | ColumnemsProbeStatusProbeIndex | read-only | mandatory | The index to the probe entry. |
| 1.3.6.1.4.1.318.1.1.10.3.13.1.1.2 | ColumnemsProbeStatusProbeName | read-only | mandatory | The name of the probe. |
| 1.3.6.1.4.1.318.1.1.10.3.13.1.1.3 | ColumnemsProbeStatusProbeTemperature | read-only | mandatory | Probe temperature reading. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or … |
| 1.3.6.1.4.1.318.1.1.10.3.13.1.1.4 | ColumnemsProbeStatusProbeHighTempThresh | read-only | mandatory | Probe high temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Cels… |
| 1.3.6.1.4.1.318.1.1.10.3.13.1.1.5 | ColumnemsProbeStatusProbeLowTempThresh | read-only | mandatory | Probe low temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsi… |
| 1.3.6.1.4.1.318.1.1.10.3.13.1.1.6 | ColumnemsProbeStatusProbeHumidity | read-only | mandatory | Probe humidity reading. Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.3.13.1.1.7 | ColumnemsProbeStatusProbeHighHumidityThresh | read-only | mandatory | Probe high humidity threshold. Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.3.13.1.1.8 | ColumnemsProbeStatusProbeLowHumidityThresh | read-only | mandatory | Probe low humidity threshold. Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.3.13.1.1.9 | ColumnemsProbeStatusProbeSerialNumber | read-only | mandatory | A label indicating the type (Local[L] or Remote[R]) and Number of the probe. For example, the first local probe would be L1 and the third remote probe would be… |
| 1.3.6.1.4.1.318.1.1.10.3.13.1.1.10 | ColumnemsProbeStatusProbeCommStatus | read-only | mandatory | The state of communications to the probe. commNeverDiscovered(1) indicates there has never been communications with this device. commsEstablished(2) indicates … |
| 1.3.6.1.4.1.318.1.1.10.3.13.1.1.11 | ColumnemsProbeStatusProbeAlarmStatus | read-only | mandatory | The alarm status of the probe. This integer should be interpreted as a bit map, with each bit representing the presence or absence of the specific alarm condit… |
| 1.3.6.1.4.1.318.1.1.10.3.13.1.1.12 | ColumnemsProbeStatusProbeMaxTempThresh | read-only | mandatory | Probe maximum temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (C… |
| 1.3.6.1.4.1.318.1.1.10.3.13.1.1.13 | ColumnemsProbeStatusProbeMinTempThresh | read-only | mandatory | Probe minimum temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (C… |
| 1.3.6.1.4.1.318.1.1.10.3.13.1.1.14 | ColumnemsProbeStatusProbeMaxHumidityThresh | read-only | mandatory | Probe maximum humidity threshold. Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.3.13.1.1.15 | ColumnemsProbeStatusProbeMinHumidityThresh | read-only | mandatory | Probe minimum humidity threshold. Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.3.14 | NodeemsInputContactStatus | |||
| 1.3.6.1.4.1.318.1.1.10.3.14.1 | TableemsInputContactStatusTable | not-accessible | mandatory | Allows for access of individual input contacts. The number of entries is contained in the emsStatusInputContactCount OID. |
| 1.3.6.1.4.1.318.1.1.10.3.14.1.1 | RowemsInputContactStatusEntry | not-accessible | mandatory | The input contacts to access. |
| 1.3.6.1.4.1.318.1.1.10.3.14.1.1.1 | ColumnemsInputContactStatusInputContactIndex | read-only | mandatory | The index to the input contact entry. |
| 1.3.6.1.4.1.318.1.1.10.3.14.1.1.2 | ColumnemsInputContactStatusInputContactName | read-only | mandatory | The name of the input contact. |
| 1.3.6.1.4.1.318.1.1.10.3.14.1.1.3 | ColumnemsInputContactStatusInputContactState | read-only | mandatory | Getting this variable will return the state of the input contact. If the input contact is closed, the contactClosedEMS (1) value will be returned. If the input… |
| 1.3.6.1.4.1.318.1.1.10.3.14.1.1.4 | ColumnemsInputContactStatusInputContactNormalState | read-only | mandatory | Getting this variable will return the normal state of the input contact. If the normal state is closed, the normallyClosedEMS (1) value will be returned. If th… |
| 1.3.6.1.4.1.318.1.1.10.3.15 | NodeemsOutputRelayStatus | |||
| 1.3.6.1.4.1.318.1.1.10.3.15.1 | TableemsOutputRelayStatusTable | not-accessible | mandatory | Allows for access of individual output relays. The number of entries is contained in the emsStatusOutputRelayCount OID. |
| 1.3.6.1.4.1.318.1.1.10.3.15.1.1 | RowemsOutputRelayStatusEntry | not-accessible | mandatory | The output relays to access. |
| 1.3.6.1.4.1.318.1.1.10.3.15.1.1.1 | ColumnemsOutputRelayStatusOutputRelayIndex | read-only | mandatory | The index to the output relay entry. |
| 1.3.6.1.4.1.318.1.1.10.3.15.1.1.2 | ColumnemsOutputRelayStatusOutputRelayName | read-only | mandatory | The name of the output relay. |
| 1.3.6.1.4.1.318.1.1.10.3.15.1.1.3 | ColumnemsOutputRelayStatusOutputRelayState | read-only | mandatory | Getting this variable will return the state of the output relay. If the output relay is closed, the relayClosedEMS (1) value will be returned. If the output re… |
| 1.3.6.1.4.1.318.1.1.10.3.15.1.1.4 | ColumnemsOutputRelayStatusOutputRelayNormalState | read-only | mandatory | Getting this variable will return the normal state of the output relay. If the normal state is closed, the normallyClosedEMS (1) value will be returned. If the… |
| 1.3.6.1.4.1.318.1.1.10.3.16 | NodeemsOutletStatus | |||
| 1.3.6.1.4.1.318.1.1.10.3.16.1 | TableemsOutletStatusTable | not-accessible | mandatory | Allows for access of individual outlets. The number of entries is contained in the emsStatusOutletCount OID. |
| 1.3.6.1.4.1.318.1.1.10.3.16.1.1 | RowemsOutletStatusEntry | not-accessible | mandatory | The outlets to access. |
| 1.3.6.1.4.1.318.1.1.10.3.16.1.1.1 | ColumnemsOutletStatusOutletIndex | read-only | mandatory | The index to the outlet entry. |
| 1.3.6.1.4.1.318.1.1.10.3.16.1.1.2 | ColumnemsOutletStatusOutletName | read-only | mandatory | The name of the outlet. |
| 1.3.6.1.4.1.318.1.1.10.3.16.1.1.3 | ColumnemsOutletStatusOutletState | read-only | mandatory | Getting this variable will return the state of the outlet. If the outlet is on, the outletOnEMS (1) value will be returned. If the outlet is off, the outletOff… |
| 1.3.6.1.4.1.318.1.1.10.3.16.1.1.4 | ColumnemsOutletStatusOutletNormalState | read-only | mandatory | Getting this variable will return the normal state of the outlet. If the normal state is on, the normallyOnEMS (1) value will be returned. If the normal state … |
| 1.3.6.1.4.1.318.1.1.10.3.17 | NodeemsAlarmDeviceStatus | |||
| 1.3.6.1.4.1.318.1.1.10.3.17.1 | TableemsAlarmDeviceStatusTable | not-accessible | mandatory | Allows for access of individual alarm devices. The number of entries is contained in the emsStatusAlarmDeviceCount OID. |
| 1.3.6.1.4.1.318.1.1.10.3.17.1.1 | RowemsAlarmDeviceStatusEntry | not-accessible | mandatory | The alarm devices to access. |
| 1.3.6.1.4.1.318.1.1.10.3.17.1.1.1 | ColumnemsAlarmDeviceStatusDeviceIndex | read-only | mandatory | The index to the alarm device entry. |
| 1.3.6.1.4.1.318.1.1.10.3.17.1.1.2 | ColumnemsAlarmDeviceStatusDeviceName | read-only | mandatory | The name of the alarm device. This OID is provided for informational purposes only. |
| 1.3.6.1.4.1.318.1.1.10.3.17.1.1.3 | ColumnemsAlarmDeviceStatusDeviceState | read-only | mandatory | Getting this variable will return the device state. If the device is active, the alarmDeviceOnEMS (1) value will be returned. If the device is inactive, the al… |
| 1.3.6.1.4.1.318.1.1.10.3.18 | NodeemsSensorStatus | |||
| 1.3.6.1.4.1.318.1.1.10.3.18.1 | TableemsSensorStatusTable | not-accessible | mandatory | Allows for access of individual sensors. The number of entries is contained in the emsStatusSensorCount OID. |
| 1.3.6.1.4.1.318.1.1.10.3.18.1.1 | RowemsSensorStatusEntry | not-accessible | mandatory | The sensors to access. |
| 1.3.6.1.4.1.318.1.1.10.3.18.1.1.1 | ColumnemsSensorStatusSensorIndex | read-only | mandatory | The index to the sensor entry. |
| 1.3.6.1.4.1.318.1.1.10.3.18.1.1.2 | ColumnemsSensorStatusSensorSystemName | read-only | mandatory | The system name of the sensor. This describes the hardware system intent of this sensor. |
| 1.3.6.1.4.1.318.1.1.10.3.18.1.1.3 | ColumnemsSensorStatusSensorName | read-only | mandatory | The name of the sensor as given by the system user. |
| 1.3.6.1.4.1.318.1.1.10.3.18.1.1.4 | ColumnemsSensorStatusSensorState | read-only | mandatory | Getting this variable will return the sensor state. If the sensor is faulted, the sensorFaultedEMS (1) value will be returned. If the sensor is not faulted, th… |
| 1.3.6.1.4.1.318.1.1.10.3.18.1.1.5 | ColumnemsSensorStatusSensorNormalState | read-only | mandatory | Getting this variable will return the normal state of the sensor. If the normal state is closed, the normallyClosedEMS (1) value will be returned. If the norma… |
| 1.3.6.1.4.1.318.1.1.10.3.18.1.1.6 | ColumnemsSensorStatusSensorAlarmDelay | read-only | mandatory | The delay (in seconds) after a sensor detects an alarm condition before the condition is reported. |
| 1.3.6.1.4.1.318.1.1.10.3.19 | NodeemsInputStateSensorConfig | |||
| 1.3.6.1.4.1.318.1.1.10.3.19.1 | TableemsSmokeSensorConfigTable | not-accessible | mandatory | Allows for the configuration of individual sensors. |
| 1.3.6.1.4.1.318.1.1.10.3.19.1.1 | RowemsSmokeSensorConfigEntry | not-accessible | mandatory | The sensors to configure. |
| 1.3.6.1.4.1.318.1.1.10.3.19.1.1.1 | ColumnemsSmokeSensorConfigSensorIndex | read-only | mandatory | The index to the sensor entry. |
| 1.3.6.1.4.1.318.1.1.10.3.19.1.1.2 | ColumnemsSmokeSensorConfigSensorName | read-write | mandatory | The user defined name of the smoke sensor. |
| 1.3.6.1.4.1.318.1.1.10.3.19.1.1.3 | ColumnemsSmokeSensorConfigSensorLocation | read-write | mandatory | The user defined location of the smoke sensor. |
| 1.3.6.1.4.1.318.1.1.10.3.19.1.1.4 | ColumnemsSmokeSensorConfigSensorSeverity | read-write | mandatory | The severity of the alarm that will be triggered when the smoke sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
| 1.3.6.1.4.1.318.1.1.10.3.19.2 | TableemsVibrationSensorConfigTable | not-accessible | mandatory | Allows for the configuration of individual sensors. |
| 1.3.6.1.4.1.318.1.1.10.3.19.2.1 | RowemsVibrationSensorConfigEntry | not-accessible | mandatory | The sensors to configure. |
| 1.3.6.1.4.1.318.1.1.10.3.19.2.1.1 | ColumnemsVibrationSensorConfigSensorIndex | read-only | mandatory | The index to the sensor entry. |
| 1.3.6.1.4.1.318.1.1.10.3.19.2.1.2 | ColumnemsVibrationSensorConfigSensorName | read-write | mandatory | The user defined name of the vibration sensor. |
| 1.3.6.1.4.1.318.1.1.10.3.19.2.1.3 | ColumnemsVibrationSensorConfigSensorLocation | read-write | mandatory | The user defined location of the vibration sensor. |
| 1.3.6.1.4.1.318.1.1.10.3.19.2.1.4 | ColumnemsVibrationSensorConfigSensorSeverity | read-write | mandatory | The severity of the alarm that will be triggered when the vibration sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
| 1.3.6.1.4.1.318.1.1.10.3.19.3 | TableemsFluidSensorConfigTable | not-accessible | mandatory | Allows for the configuration of individual sensors. |
| 1.3.6.1.4.1.318.1.1.10.3.19.3.1 | RowemsFluidSensorConfigEntry | not-accessible | mandatory | The sensors to configure. |
| 1.3.6.1.4.1.318.1.1.10.3.19.3.1.1 | ColumnemsFluidSensorConfigSensorIndex | read-only | mandatory | The index to the sensor entry. |
| 1.3.6.1.4.1.318.1.1.10.3.19.3.1.2 | ColumnemsFluidSensorConfigSensorName | read-write | mandatory | The user defined name of the fluid sensor. |
| 1.3.6.1.4.1.318.1.1.10.3.19.3.1.3 | ColumnemsFluidSensorConfigSensorLocation | read-write | mandatory | The user defined location of the fluid sensor. |
| 1.3.6.1.4.1.318.1.1.10.3.19.3.1.4 | ColumnemsFluidSensorConfigSensorSeverity | read-write | mandatory | The severity of the alarm that will be triggered when the fluid sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
| 1.3.6.1.4.1.318.1.1.10.3.19.4 | TableemsDoorSensorConfigTable | not-accessible | mandatory | Allows for the configuration of individual sensors. |
| 1.3.6.1.4.1.318.1.1.10.3.19.4.1 | RowemsDoorSensorConfigEntry | not-accessible | mandatory | The sensors to configure. |
| 1.3.6.1.4.1.318.1.1.10.3.19.4.1.1 | ColumnemsDoorSensorConfigSensorIndex | read-only | mandatory | The index to the sensor entry. |
| 1.3.6.1.4.1.318.1.1.10.3.19.4.1.2 | ColumnemsDoorSensorConfigSensorName | read-write | mandatory | The user defined name of the door sensor. |
| 1.3.6.1.4.1.318.1.1.10.3.19.4.1.3 | ColumnemsDoorSensorConfigSensorLocation | read-write | mandatory | The user defined location of the door sensor. |
| 1.3.6.1.4.1.318.1.1.10.3.19.4.1.4 | ColumnemsDoorSensorConfigSensorSeverity | read-write | mandatory | The severity of the alarm that will be triggered when the door sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
| 1.3.6.1.4.1.318.1.1.10.3.20 | NodeemsInputStateSensorStatus | |||
| 1.3.6.1.4.1.318.1.1.10.3.20.1 | ScalaremsSmokeSensorStatusTableSize | read-only | mandatory | The number of entries in the emsSmokeSensorStatusTable. |
| 1.3.6.1.4.1.318.1.1.10.3.20.2 | TableemsSmokeSensorStatusTable | not-accessible | mandatory | Allows for the access of individual sensors. |
| 1.3.6.1.4.1.318.1.1.10.3.20.2.1 | RowemsSmokeSensorStatusEntry | not-accessible | mandatory | The sensor to access. |
| 1.3.6.1.4.1.318.1.1.10.3.20.2.1.1 | ColumnemsSmokeSensorStatusSensorIndex | read-only | mandatory | The index to the sensor entry. |
| 1.3.6.1.4.1.318.1.1.10.3.20.2.1.2 | ColumnemsSmokeSensorStatusSensorName | read-only | mandatory | The user defined name of the smoke sensor. |
| 1.3.6.1.4.1.318.1.1.10.3.20.2.1.3 | ColumnemsSmokeSensorStatusSensorLocation | read-only | mandatory | The user defined location of the smoke sensor. |
| 1.3.6.1.4.1.318.1.1.10.3.20.2.1.4 | ColumnemsSmokeSensorStatusSensorState | read-only | mandatory | The state of the smoke sensor. smokeDetected (1) indicates there is smoke. noSmoke (2) indicates there is no smoke. unknown (3) indicates the state is unknown. |
| 1.3.6.1.4.1.318.1.1.10.3.20.2.1.5 | ColumnemsSmokeSensorStatusSensorSeverity | read-only | mandatory | The severity of the alarm that will be triggered when the smoke sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
| 1.3.6.1.4.1.318.1.1.10.3.20.2.1.6 | ColumnemsSmokeSensorCommStatus | read-only | mandatory | The communication status of the smoke sensor. |
| 1.3.6.1.4.1.318.1.1.10.3.20.3 | ScalaremsVibrationSensorStatusTableSize | read-only | mandatory | The number of entries in the emsVibrationSensorStatusTable. |
| 1.3.6.1.4.1.318.1.1.10.3.20.4 | TableemsVibrationSensorStatusTable | not-accessible | mandatory | Allows for the access of individual sensors. |
| 1.3.6.1.4.1.318.1.1.10.3.20.4.1 | RowemsVibrationSensorStatusEntry | not-accessible | mandatory | The sensor to access. |
| 1.3.6.1.4.1.318.1.1.10.3.20.4.1.1 | ColumnemsVibrationSensorStatusSensorIndex | read-only | mandatory | The index to the sensor entry. |
| 1.3.6.1.4.1.318.1.1.10.3.20.4.1.2 | ColumnemsVibrationSensorStatusSensorName | read-only | mandatory | The user defined name of the vibration sensor. |
| 1.3.6.1.4.1.318.1.1.10.3.20.4.1.3 | ColumnemsVibrationSensorStatusSensorLocation | read-only | mandatory | The user defined location of the vibration sensor. |
| 1.3.6.1.4.1.318.1.1.10.3.20.4.1.4 | ColumnemsVibrationSensorStatusSensorState | read-only | mandatory | The state of the vibration sensor. vibrationDetected (1) indicates there is vibration. noVibration (2) indicates there is no vibration. unknown (3) indicates t… |
| 1.3.6.1.4.1.318.1.1.10.3.20.4.1.5 | ColumnemsVibrationSensorStatusSensorSeverity | read-only | mandatory | The severity of the alarm that will be triggered when the vibration sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
| 1.3.6.1.4.1.318.1.1.10.3.20.4.1.6 | ColumnemsVibrationSensorCommStatus | read-only | mandatory | The communication status of the vibration sensor. |
| 1.3.6.1.4.1.318.1.1.10.3.20.5 | ScalaremsFluidSensorStatusTableSize | read-only | mandatory | The number of entries in the emsFluidSensorStatusTable. |
| 1.3.6.1.4.1.318.1.1.10.3.20.6 | TableemsFluidSensorStatusTable | not-accessible | mandatory | Allows for the access of individual sensors. |
| 1.3.6.1.4.1.318.1.1.10.3.20.6.1 | RowemsFluidSensorStatusEntry | not-accessible | mandatory | The sensors to access. |
| 1.3.6.1.4.1.318.1.1.10.3.20.6.1.1 | ColumnemsFluidSensorStatusSensorIndex | read-only | mandatory | The index to the sensor entry. |
| 1.3.6.1.4.1.318.1.1.10.3.20.6.1.2 | ColumnemsFluidSensorStatusSensorName | read-only | mandatory | The user defined name of the fluid sensor. |
| 1.3.6.1.4.1.318.1.1.10.3.20.6.1.3 | ColumnemsFluidSensorStatusSensorLocation | read-only | mandatory | The user defined location of the fluid sensor. |
| 1.3.6.1.4.1.318.1.1.10.3.20.6.1.4 | ColumnemsFluidSensorStatusSensorState | read-only | mandatory | The state of the fluid sensor. fluidDetected (1) indicates there is fluid leak. noFluid (2) indicates there is no fluid leak. unknown (3) indicates the state i… |
| 1.3.6.1.4.1.318.1.1.10.3.20.6.1.5 | ColumnemsFluidSensorStatusSensorSeverity | read-only | mandatory | The severity of the alarm that will be triggered when the fluid sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
| 1.3.6.1.4.1.318.1.1.10.3.20.6.1.6 | ColumnemsFluidSensorCommStatus | read-only | mandatory | The communication status of the fluid sensor. |
| 1.3.6.1.4.1.318.1.1.10.3.20.7 | ScalaremsDoorSensorStatusTableSize | read-only | mandatory | The number of entries in the emsDoorSensorStatusTable. |
| 1.3.6.1.4.1.318.1.1.10.3.20.8 | TableemsDoorSensorStatusTable | not-accessible | mandatory | Allows for the access of individual sensors. |
| 1.3.6.1.4.1.318.1.1.10.3.20.8.1 | RowemsDoorSensorStatusEntry | not-accessible | mandatory | The sensor to access. |
| 1.3.6.1.4.1.318.1.1.10.3.20.8.1.1 | ColumnemsDoorSensorStatusSensorIndex | read-only | mandatory | The index to the sensor entry. |
| 1.3.6.1.4.1.318.1.1.10.3.20.8.1.2 | ColumnemsDoorSensorStatusSensorName | read-only | mandatory | The user defined name of the door sensor. |
| 1.3.6.1.4.1.318.1.1.10.3.20.8.1.3 | ColumnemsDoorSensorStatusSensorLocation | read-only | mandatory | The user defined location of the door sensor. |
| 1.3.6.1.4.1.318.1.1.10.3.20.8.1.4 | ColumnemsDoorSensorStatusSensorState | read-only | mandatory | The state of the door sensor. open (1) indicates door open. closed (2) indicates door closed. unknown (3) indicates the state is unknown. |
| 1.3.6.1.4.1.318.1.1.10.3.20.8.1.5 | ColumnemsDoorSensorStatusSensorSeverity | read-only | mandatory | The severity of the alarm that will be triggered when the door sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
| 1.3.6.1.4.1.318.1.1.10.3.20.8.1.6 | ColumnemsDoorSensorCommStatus | read-only | mandatory | The communication status of the door sensor. |
| 1.3.6.1.4.1.318.1.1.10.4 | NodemodEnvMgr | |||
| 1.3.6.1.4.1.318.1.1.10.4.1 | NodememModules | |||
| 1.3.6.1.4.1.318.1.1.10.4.1.1 | ScalarmemModulesStatusTableSize | read-only | mandatory | The number of entries in the memModulesStatusTable. |
| 1.3.6.1.4.1.318.1.1.10.4.1.2 | TablememModulesStatusTable | not-accessible | mandatory | Allows for getting status information from the modules attached to the system. |
| 1.3.6.1.4.1.318.1.1.10.4.1.2.1 | RowmemModulesStatusEntry | not-accessible | mandatory | The unit to get data from. |
| 1.3.6.1.4.1.318.1.1.10.4.1.2.1.1 | ColumnmemModulesStatusModuleNumber | read-only | mandatory | The module number. |
| 1.3.6.1.4.1.318.1.1.10.4.1.2.1.2 | ColumnmemModulesStatusModuleName | read-only | mandatory | The module name. |
| 1.3.6.1.4.1.318.1.1.10.4.1.2.1.3 | ColumnmemModulesStatusModuleLocation | read-only | mandatory | The location of the module. |
| 1.3.6.1.4.1.318.1.1.10.4.1.2.1.4 | ColumnmemModulesStatusModelNumber | read-only | mandatory | The model number of the module. |
| 1.3.6.1.4.1.318.1.1.10.4.1.2.1.5 | ColumnmemModulesStatusSerialNumber | read-only | mandatory | The serial number of the module. |
| 1.3.6.1.4.1.318.1.1.10.4.1.2.1.6 | ColumnmemModulesStatusFirmwareRev | read-only | mandatory | The firmware revision of the module. |
| 1.3.6.1.4.1.318.1.1.10.4.1.2.1.7 | ColumnmemModulesStatusHardwareRev | read-only | mandatory | The hardware revision. |
| 1.3.6.1.4.1.318.1.1.10.4.1.3 | ScalarmemModulesConfigTableSize | read-only | mandatory | The number of entries in the memModulesConfigTable. |
| 1.3.6.1.4.1.318.1.1.10.4.1.4 | TablememModulesConfigTable | not-accessible | mandatory | Allows for getting status information from the modules attached to the system. |
| 1.3.6.1.4.1.318.1.1.10.4.1.4.1 | RowmemModulesConfigEntry | not-accessible | mandatory | The unit to get data from. |
| 1.3.6.1.4.1.318.1.1.10.4.1.4.1.1 | ColumnmemModulesConfigModuleNumber | read-only | mandatory | The module number. |
| 1.3.6.1.4.1.318.1.1.10.4.1.4.1.2 | ColumnmemModulesConfigModuleName | read-write | mandatory | The module name. |
| 1.3.6.1.4.1.318.1.1.10.4.1.4.1.3 | ColumnmemModulesConfigModuleLocation | read-write | mandatory | The location of the module. |
| 1.3.6.1.4.1.318.1.1.10.4.2 | NodememSensors | |||
| 1.3.6.1.4.1.318.1.1.10.4.2.1 | ScalarmemSensorsStatusSysTempUnits | read-only | mandatory | The temperature scale used to display the temperature in the system, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration… |
| 1.3.6.1.4.1.318.1.1.10.4.2.2 | ScalarmemSensorsStatusTableSize | read-only | mandatory | The number of entries in the memSensorsStatusTable. |
| 1.3.6.1.4.1.318.1.1.10.4.2.3 | TablememSensorsStatusTable | not-accessible | mandatory | Allows for getting sensor status information. |
| 1.3.6.1.4.1.318.1.1.10.4.2.3.1 | RowmemSensorsStatusEntry | not-accessible | mandatory | The unit to get data from. |
| 1.3.6.1.4.1.318.1.1.10.4.2.3.1.1 | ColumnmemSensorsStatusModuleNumber | read-only | mandatory | The number of the module that the sensor is attached to. |
| 1.3.6.1.4.1.318.1.1.10.4.2.3.1.2 | ColumnmemSensorsStatusSensorNumber | read-only | mandatory | The number of this sensor on the module. |
| 1.3.6.1.4.1.318.1.1.10.4.2.3.1.3 | ColumnmemSensorsStatusSensorName | read-only | mandatory | The sensor name. |
| 1.3.6.1.4.1.318.1.1.10.4.2.3.1.4 | ColumnmemSensorsStatusSensorLocation | read-only | mandatory | The location of the sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.2.3.1.5 | ColumnmemSensorsTemperature | read-only | mandatory | The sensor's current temperature reading. Units are displayed in the scale shown in the memSensorsStatusSysTempUnits OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.4.2.3.1.6 | ColumnmemSensorsHumidity | read-only | mandatory | The current humidity reading from the sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.2.3.1.7 | ColumnmemSensorsCommStatus | read-only | mandatory | The communications status of the sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.2.3.1.8 | ColumnmemSensorsAlarmStatus | read-only | mandatory | The alarm status of the sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.2.3.1.9 | ColumnmemSensorsTemperatureHighPrec | read-only | mandatory | The current temperature is displayed in tenths of degrees in the scale shown in the memSensorsStatusSysTempUnits OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.4.2.4 | ScalarmemSensorsConfigTableSize | read-only | mandatory | The number of entries in the memSensorsConfigTable. |
| 1.3.6.1.4.1.318.1.1.10.4.2.5 | TablememSensorsConfigTable | not-accessible | mandatory | Allows for getting configuration information from sensors attached to the system. |
| 1.3.6.1.4.1.318.1.1.10.4.2.5.1 | RowmemSensorsConfigEntry | not-accessible | mandatory | The unit to get data from. |
| 1.3.6.1.4.1.318.1.1.10.4.2.5.1.1 | ColumnmemSensorsConfigModuleNumber | read-only | mandatory | The number of the module that the sensor is attached to. |
| 1.3.6.1.4.1.318.1.1.10.4.2.5.1.2 | ColumnmemSensorsConfigSensorNumber | read-only | mandatory | The number of this sensor on the module. |
| 1.3.6.1.4.1.318.1.1.10.4.2.5.1.3 | ColumnmemSensorsName | read-write | mandatory | A descriptive name for the sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.2.5.1.4 | ColumnmemSensorsLocation | read-write | mandatory | The location of the sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.2.5.1.5 | ColumnmemSensorsAlarmGeneration | read-write | mandatory | Enable or disable alarm generation on this sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.2.5.1.6 | ColumnmemSensorsTempMaxThresh | read-write | mandatory | The temperature at which the MEM will generate a maximum temperature threshold violation alarm on this sensor. The temperature scale is based on the memSensors… |
| 1.3.6.1.4.1.318.1.1.10.4.2.5.1.7 | ColumnmemSensorsTempHighThresh | read-write | mandatory | The temperature at which the MEM will generate a high temperature threshold violation alarm on this sensor. The temperature scale is based on the memSensorsSta… |
| 1.3.6.1.4.1.318.1.1.10.4.2.5.1.8 | ColumnmemSensorsTempLowThresh | read-write | mandatory | The temperature at which the MEM will generate a low temperature threshold violation alarm on this sensor. The temperature scale is based on the memSensorsStat… |
| 1.3.6.1.4.1.318.1.1.10.4.2.5.1.9 | ColumnmemSensorsTempMinThresh | read-write | mandatory | The temperature at which the MEM will generate a minimum temperature threshold violation alarm on this sensor. The temperature scale is based on the memSensors… |
| 1.3.6.1.4.1.318.1.1.10.4.2.5.1.10 | ColumnmemSensorsTempThreshHysteresis | read-write | mandatory | The change in temperature required to cause a temperature alarm to change from an active to an inactive state. The temperature scale is based on the memSensors… |
| 1.3.6.1.4.1.318.1.1.10.4.2.5.1.11 | ColumnmemSensorsTempShortDecRateThreshValue | read-write | mandatory | The value of the temperature short-term decreasing rate time that will cause an alarm to be generated. The temperature scale is based on the memSensorsStatusSy… |
| 1.3.6.1.4.1.318.1.1.10.4.2.5.1.12 | ColumnmemSensorsTempShortDecRateThreshTime | read-write | mandatory | The time over which the temperature may not decrease beyond the value specified by the temperature short-term decreasing rate threshold value. |
| 1.3.6.1.4.1.318.1.1.10.4.2.5.1.13 | ColumnmemSensorsTempShortIncRateThreshValue | read-write | mandatory | The value of the temperature short-term increasing rate time that will cause an alarm to be generated. The temperature scale is based on the memSensorsStatusSy… |
| 1.3.6.1.4.1.318.1.1.10.4.2.5.1.14 | ColumnmemSensorsTempShortIncRateThreshTime | read-write | mandatory | The time over which the temperature may not increase beyond the value specified by the temperature short-term increasing rate threshold value. |
| 1.3.6.1.4.1.318.1.1.10.4.2.5.1.15 | ColumnmemSensorsTempLongDecRateThreshValue | read-write | mandatory | The value of the temperature long-term decreasing rate time that will cause an alarm to be generated. The temperature scale is based on the memSensorsStatusSys… |
| 1.3.6.1.4.1.318.1.1.10.4.2.5.1.16 | ColumnmemSensorsTempLongDecRateThreshTime | read-write | mandatory | The time over which the temperature may not decrease beyond the value specified by the temperature long-term decreasing rate threshold value. |
| 1.3.6.1.4.1.318.1.1.10.4.2.5.1.17 | ColumnmemSensorsTempLongIncRateThreshValue | read-write | mandatory | The value of the temperature long-term increasing rate time that will cause an alarm to be generated. The temperature scale is based on the memSensorsStatusSys… |
| 1.3.6.1.4.1.318.1.1.10.4.2.5.1.18 | ColumnmemSensorsTempLongIncRateThreshTime | read-write | mandatory | The time over which the temperature may not increase beyond the value specified by the temperature long-term increasing rate threshold value. |
| 1.3.6.1.4.1.318.1.1.10.4.2.5.1.19 | ColumnmemSensorsHumidityMaxThresh | read-write | mandatory | The humidity at which the maximum humidity threshold alarm will be generated. |
| 1.3.6.1.4.1.318.1.1.10.4.2.5.1.20 | ColumnmemSensorsHumidityHighThresh | read-write | mandatory | The humidity at which the high humidity threshold alarm will be generated. |
| 1.3.6.1.4.1.318.1.1.10.4.2.5.1.21 | ColumnmemSensorsHumidityLowThresh | read-write | mandatory | The humidity at which the low humidity threshold alarm will be generated. |
| 1.3.6.1.4.1.318.1.1.10.4.2.5.1.22 | ColumnmemSensorsHumidityMinThresh | read-write | mandatory | The humidity at which the minimum humidity threshold alarm will be generated. |
| 1.3.6.1.4.1.318.1.1.10.4.2.5.1.23 | ColumnmemSensorsHumidityThreshHysteresis | read-write | mandatory | The change in humidity required to cause an active humidity alarm to change to the inactive state. |
| 1.3.6.1.4.1.318.1.1.10.4.3 | NodememInputs | |||
| 1.3.6.1.4.1.318.1.1.10.4.3.1 | ScalarmemInputsStatusTableSize | read-only | mandatory | The number of entries in the memInputsStatusTable. |
| 1.3.6.1.4.1.318.1.1.10.4.3.2 | TablememInputsStatusTable | not-accessible | mandatory | Allows for getting input status information. |
| 1.3.6.1.4.1.318.1.1.10.4.3.2.1 | RowmemInputsStatusEntry | not-accessible | mandatory | The unit to get data from. |
| 1.3.6.1.4.1.318.1.1.10.4.3.2.1.1 | ColumnmemInputsStatusModuleNumber | read-only | mandatory | The number of the module that the input is attached to. |
| 1.3.6.1.4.1.318.1.1.10.4.3.2.1.2 | ColumnmemInputsStatusInputNumber | read-only | mandatory | The number of this input on the module. |
| 1.3.6.1.4.1.318.1.1.10.4.3.2.1.3 | ColumnmemInputsStatusInputName | read-only | mandatory | The input name. |
| 1.3.6.1.4.1.318.1.1.10.4.3.2.1.4 | ColumnmemInputsStatusInputLocation | read-only | mandatory | The location of the input. |
| 1.3.6.1.4.1.318.1.1.10.4.3.2.1.5 | ColumnmemInputsStatusCurrentState | read-only | mandatory | The current state of the input. This OID will return inputStateNotAplicable(4) for analog input types. |
| 1.3.6.1.4.1.318.1.1.10.4.3.2.1.6 | ColumnmemInputsStatusCurrentAnalogValue | read-only | mandatory | The current analog value of the input in the units defined by the user. |
| 1.3.6.1.4.1.318.1.1.10.4.3.2.1.7 | ColumnmemInputsStatusAlarmStatus | read-only | mandatory | The alarm status of the input. |
| 1.3.6.1.4.1.318.1.1.10.4.3.2.1.8 | ColumnmemInputsCommStatus | read-only | mandatory | The communications status of the input. This OID is only supported by NBRK0200. |
| 1.3.6.1.4.1.318.1.1.10.4.3.3 | ScalarmemInputsConfigTableSize | read-only | mandatory | The number of entries in the memInputsConfigTable. |
| 1.3.6.1.4.1.318.1.1.10.4.3.4 | TablememInputsConfigTable | not-accessible | mandatory | Allows for getting input configuration information. |
| 1.3.6.1.4.1.318.1.1.10.4.3.4.1 | RowmemInputsConfigEntry | not-accessible | mandatory | The unit to get data from. |
| 1.3.6.1.4.1.318.1.1.10.4.3.4.1.1 | ColumnmemInputsConfigModuleNumber | read-only | mandatory | The number of the module that the input is attached to. |
| 1.3.6.1.4.1.318.1.1.10.4.3.4.1.2 | ColumnmemInputsConfigInputNumber | read-only | mandatory | The number of this input on the module. |
| 1.3.6.1.4.1.318.1.1.10.4.3.4.1.3 | ColumnmemInputName | read-write | mandatory | The name of the input. |
| 1.3.6.1.4.1.318.1.1.10.4.3.4.1.4 | ColumnmemInputLocation | read-write | mandatory | The location of the input. |
| 1.3.6.1.4.1.318.1.1.10.4.3.4.1.5 | ColumnmemInputType | read-write | mandatory | The type of input this contact will take. |
| 1.3.6.1.4.1.318.1.1.10.4.3.4.1.6 | ColumnmemInputAlarmGeneration | read-write | mandatory | Enable or disable alarm generation on this input. |
| 1.3.6.1.4.1.318.1.1.10.4.3.4.1.7 | ColumnmemInputNormalState | read-write | mandatory | Defines the normal (no alarm) state of the input. |
| 1.3.6.1.4.1.318.1.1.10.4.3.4.1.8 | ColumnmemInputAbnormalSeverity | read-write | mandatory | Defines the severity of the event that is associated with the abnormal state of the input. This OID will return inputSeverityNotApplicable(4) for analog input … |
| 1.3.6.1.4.1.318.1.1.10.4.3.4.1.9 | ColumnmemInputNumberCalibrationPoints | read-write | mandatory | The number of calibration points that are required for this input. |
| 1.3.6.1.4.1.318.1.1.10.4.3.4.1.10 | ColumnmemInputAnalogCalibrationPoint1 | read-write | mandatory | The electrical value that the input sensor will measure at the first calibration point. This OID is relevant only for inputs configured as analog type (ma or V… |
| 1.3.6.1.4.1.318.1.1.10.4.3.4.1.11 | ColumnmemInputAnalogCalibrationPoint2 | read-write | mandatory | The electrical value that the input sensor will measure at the second calibration point. This OID is relevant only for inputs configured as analog type (ma or … |
| 1.3.6.1.4.1.318.1.1.10.4.3.4.1.12 | ColumnmemInputAnalogCalibrationPoint3 | read-write | mandatory | The electrical value that the input sensor will measure at the third calibration point. This OID is relevant only for inputs configured as analog type (ma or V… |
| 1.3.6.1.4.1.318.1.1.10.4.3.4.1.13 | ColumnmemInputAnalogCalibrationPoint4 | read-write | mandatory | The electrical value that the input sensor will measure at the fourth calibration point. This OID is relevant only for inputs configured as analog type (ma or … |
| 1.3.6.1.4.1.318.1.1.10.4.3.4.1.14 | ColumnmemInputAnalogCalibrationPoint5 | read-write | mandatory | The electrical value that the input sensor will measure at the fifth calibration point. This OID is relevant only for inputs configured as analog type (ma or V… |
| 1.3.6.1.4.1.318.1.1.10.4.3.4.1.15 | ColumnmemInputAnalogCalibrationPoint1Value | read-write | mandatory | The value of the input, in units of measure defined by the user, that corresponds to the current setting at the first calibration point. |
| 1.3.6.1.4.1.318.1.1.10.4.3.4.1.16 | ColumnmemInputAnalogCalibrationPoint2Value | read-write | mandatory | The value of the input, in units of measure defined by the user, that corresponds to the current setting at the second calibration point. |
| 1.3.6.1.4.1.318.1.1.10.4.3.4.1.17 | ColumnmemInputAnalogCalibrationPoint3Value | read-write | mandatory | The value of the input, in units of measure defined by the user, that corresponds to the current setting at the third calibration point. |
| 1.3.6.1.4.1.318.1.1.10.4.3.4.1.18 | ColumnmemInputAnalogCalibrationPoint4Value | read-write | mandatory | The value of the input, in units of measure defined by the user, that corresponds to the current setting at the fourth calibration point. |
| 1.3.6.1.4.1.318.1.1.10.4.3.4.1.19 | ColumnmemInputAnalogCalibrationPoint5Value | read-write | mandatory | The value of the input, in units of measure defined by the user, that corresponds to the current setting at the fifth calibration point. |
| 1.3.6.1.4.1.318.1.1.10.4.3.4.1.20 | ColumnmemInputAnalogMeasurementUnits | read-write | mandatory | The units of measure to be used for this input. |
| 1.3.6.1.4.1.318.1.1.10.4.3.4.1.21 | ColumnmemInputAnalogMaxThresh | read-write | mandatory | The input value at which a maximum threshold violation alarm will be generated on this input. |
| 1.3.6.1.4.1.318.1.1.10.4.3.4.1.22 | ColumnmemInputAnalogHighThresh | read-write | mandatory | The input value at which a high threshold violation alarm will be generated on this input. |
| 1.3.6.1.4.1.318.1.1.10.4.3.4.1.23 | ColumnmemInputAnalogLowThresh | read-write | mandatory | The input value at which a low threshold violation alarm will be generated on this input. |
| 1.3.6.1.4.1.318.1.1.10.4.3.4.1.24 | ColumnmemInputAnalogMinThresh | read-write | mandatory | The input value at which a minimum threshold violation alarm will be generated on this input. |
| 1.3.6.1.4.1.318.1.1.10.4.3.4.1.25 | ColumnmemInputAnalogThreshHysteresis | read-write | mandatory | The change in value required to cause an alarm on this input to change from active to inactive. |
| 1.3.6.1.4.1.318.1.1.10.4.4 | NodememOutputs | |||
| 1.3.6.1.4.1.318.1.1.10.4.4.1 | ScalarmemOutputStatusTableSize | read-only | mandatory | The number of entries in the memOutputStatusTable. |
| 1.3.6.1.4.1.318.1.1.10.4.4.2 | TablememOutputStatusTable | not-accessible | mandatory | Allows for getting output status information. |
| 1.3.6.1.4.1.318.1.1.10.4.4.2.1 | RowmemOutputStatusEntry | not-accessible | mandatory | The unit to get data from. |
| 1.3.6.1.4.1.318.1.1.10.4.4.2.1.1 | ColumnmemOutputStatusModuleNumber | read-only | mandatory | The number of the module that the output is attached to. |
| 1.3.6.1.4.1.318.1.1.10.4.4.2.1.2 | ColumnmemOutputStatusOutputNumber | read-only | mandatory | The number of this output on the module. |
| 1.3.6.1.4.1.318.1.1.10.4.4.2.1.3 | ColumnmemOutputStatusOutputName | read-only | mandatory | The output name. |
| 1.3.6.1.4.1.318.1.1.10.4.4.2.1.4 | ColumnmemOutputStatusOutputLocation | read-only | mandatory | The location of the output. |
| 1.3.6.1.4.1.318.1.1.10.4.4.2.1.5 | ColumnmemOutputStatusCurrentState | read-only | mandatory | The state of the output. |
| 1.3.6.1.4.1.318.1.1.10.4.4.2.1.6 | ColumnmemOutputStatusAlarmState | read-only | mandatory | The alarm state of the output. |
| 1.3.6.1.4.1.318.1.1.10.4.4.3 | ScalarmemOutputConfigTableSize | read-only | mandatory | The number of entries in the memOutputConfigTable. |
| 1.3.6.1.4.1.318.1.1.10.4.4.4 | TablememOutputConfigTable | not-accessible | mandatory | Allows for getting output configuration information. |
| 1.3.6.1.4.1.318.1.1.10.4.4.4.1 | RowmemOutputConfigEntry | not-accessible | mandatory | The unit to get data from. |
| 1.3.6.1.4.1.318.1.1.10.4.4.4.1.1 | ColumnmemOutputConfigModuleNumber | read-only | mandatory | The number of the module that the output is attached to. |
| 1.3.6.1.4.1.318.1.1.10.4.4.4.1.2 | ColumnmemOutputConfigOutputNumber | read-only | mandatory | The number of this output on the module. |
| 1.3.6.1.4.1.318.1.1.10.4.4.4.1.3 | ColumnmemOutputName | read-write | mandatory | The name of the output. |
| 1.3.6.1.4.1.318.1.1.10.4.4.4.1.4 | ColumnmemOutputLocation | read-write | mandatory | The location of the output. |
| 1.3.6.1.4.1.318.1.1.10.4.4.4.1.5 | ColumnmemOutputNormalState | read-write | mandatory | The state of the output that will not generate an alarm. |
| 1.3.6.1.4.1.318.1.1.10.4.4.4.1.6 | ColumnmemOutputAction | read-write | mandatory | Manual control actions for the output. SNMP get command will return the state of the output, SNMP set of this OID controls the output. |
| 1.3.6.1.4.1.318.1.1.10.4.5 | NodememOutlets | |||
| 1.3.6.1.4.1.318.1.1.10.4.5.1 | ScalarmemOutletStatusTableSize | read-only | mandatory | The number of entries in the memOutletStatusTable. |
| 1.3.6.1.4.1.318.1.1.10.4.5.2 | TablememOutletStatusTable | not-accessible | mandatory | Allows for getting outlet status information. |
| 1.3.6.1.4.1.318.1.1.10.4.5.2.1 | RowmemOutletStatusEntry | not-accessible | mandatory | The unit to get data from. |
| 1.3.6.1.4.1.318.1.1.10.4.5.2.1.1 | ColumnmemOutletStatusModuleNumber | read-only | mandatory | The number of the module that the outlet is attached to. |
| 1.3.6.1.4.1.318.1.1.10.4.5.2.1.2 | ColumnmemOutletStatusOutletNumber | read-only | mandatory | The number of this outlet on the module. |
| 1.3.6.1.4.1.318.1.1.10.4.5.2.1.3 | ColumnmemOutletStatusOutletName | read-only | mandatory | The outlet name. |
| 1.3.6.1.4.1.318.1.1.10.4.5.2.1.4 | ColumnmemOutletStatusOutletLocation | read-only | mandatory | The location of the outlet. |
| 1.3.6.1.4.1.318.1.1.10.4.5.2.1.5 | ColumnmemOutletStatusCurrentState | read-only | mandatory | The state of the outlet. |
| 1.3.6.1.4.1.318.1.1.10.4.5.2.1.6 | ColumnmemOutletStatusAlarmState | read-only | mandatory | The alarm state of the outlet. |
| 1.3.6.1.4.1.318.1.1.10.4.5.3 | ScalarmemOutletConfigTableSize | read-only | mandatory | The number of entries in the memOutletConfigTable. |
| 1.3.6.1.4.1.318.1.1.10.4.5.4 | TablememOutletConfigTable | not-accessible | mandatory | Allows for getting outlet configuration information. |
| 1.3.6.1.4.1.318.1.1.10.4.5.4.1 | RowmemOutletConfigEntry | not-accessible | mandatory | The unit to get data from. |
| 1.3.6.1.4.1.318.1.1.10.4.5.4.1.1 | ColumnmemOutletConfigModuleNumber | read-only | mandatory | The number of the module that the Outlet is attached to. |
| 1.3.6.1.4.1.318.1.1.10.4.5.4.1.2 | ColumnmemOutletConfigOutletNumber | read-only | mandatory | The number of this Outlet on the module. |
| 1.3.6.1.4.1.318.1.1.10.4.5.4.1.3 | ColumnmemOutletName | read-write | mandatory | The name of the Outlet. |
| 1.3.6.1.4.1.318.1.1.10.4.5.4.1.4 | ColumnmemOutletLocation | read-write | mandatory | The location of the Outlet. |
| 1.3.6.1.4.1.318.1.1.10.4.5.4.1.5 | ColumnmemOutletNormalState | read-write | mandatory | The state of the Outlet that will not generate an alarm. |
| 1.3.6.1.4.1.318.1.1.10.4.5.4.1.6 | ColumnmemOutletAction | read-write | mandatory | Manual control actions for the Outlet. Get displays state of outlet, set controls outlet. |
| 1.3.6.1.4.1.318.1.1.10.4.6 | NodememBeacons | |||
| 1.3.6.1.4.1.318.1.1.10.4.6.1 | ScalarmemBeaconStatusTableSize | read-only | mandatory | The number of entries in the memBeaconStatusTable. |
| 1.3.6.1.4.1.318.1.1.10.4.6.2 | TablememBeaconStatusTable | not-accessible | mandatory | Allows for getting beacon status information. |
| 1.3.6.1.4.1.318.1.1.10.4.6.2.1 | RowmemBeaconStatusEntry | not-accessible | mandatory | The unit to get data from. |
| 1.3.6.1.4.1.318.1.1.10.4.6.2.1.1 | ColumnmemBeaconStatusModuleNumber | read-only | mandatory | The number of the module that the beacon is attached to. |
| 1.3.6.1.4.1.318.1.1.10.4.6.2.1.2 | ColumnmemBeaconStatusBeaconNumber | read-only | mandatory | The number of this beacon on the module. |
| 1.3.6.1.4.1.318.1.1.10.4.6.2.1.3 | ColumnmemBeaconStatusBeaconName | read-only | mandatory | The beacon name. |
| 1.3.6.1.4.1.318.1.1.10.4.6.2.1.4 | ColumnmemBeaconStatusBeaconLocation | read-only | mandatory | The location of the beacon. |
| 1.3.6.1.4.1.318.1.1.10.4.6.2.1.5 | ColumnmemBeaconStatusCurrentState | read-only | mandatory | The state of the beacon. |
| 1.3.6.1.4.1.318.1.1.10.4.6.2.1.6 | ColumnmemBeaconStatusAlarmState | read-only | mandatory | The alarm state of the beacon. |
| 1.3.6.1.4.1.318.1.1.10.4.6.3 | ScalarmemBeaconConfigTableSize | read-only | mandatory | The number of entries in the memBeaconConfigTable. |
| 1.3.6.1.4.1.318.1.1.10.4.6.4 | TablememBeaconConfigTable | not-accessible | mandatory | Allows for getting beacon configuration information. |
| 1.3.6.1.4.1.318.1.1.10.4.6.4.1 | RowmemBeaconConfigEntry | not-accessible | mandatory | The unit to get data from. |
| 1.3.6.1.4.1.318.1.1.10.4.6.4.1.1 | ColumnmemBeaconConfigModuleNumber | read-only | mandatory | The number of the module that the beacon is attached to. |
| 1.3.6.1.4.1.318.1.1.10.4.6.4.1.2 | ColumnmemBeaconConfigBeaconNumber | read-only | mandatory | The number of this beacon on the module. |
| 1.3.6.1.4.1.318.1.1.10.4.6.4.1.3 | ColumnmemBeaconConfigName | read-write | mandatory | The name of the beacon. |
| 1.3.6.1.4.1.318.1.1.10.4.6.4.1.4 | ColumnmemBeaconConfigLocation | read-write | mandatory | The location of the beacon. |
| 1.3.6.1.4.1.318.1.1.10.4.6.4.1.5 | ColumnmemBeaconAction | read-write | mandatory | Control action (on/off) for the beacon. Setting this OID will turn the beacon on/off. Getting this OID will respond with the current state. |
| 1.3.6.1.4.1.318.1.1.10.4.7 | NodememInputStateSensors | |||
| 1.3.6.1.4.1.318.1.1.10.4.7.1 | ScalarmemSmokeSensorStatusTableSize | read-only | mandatory | The number of entries in the memSmokeSensorStatusTable. |
| 1.3.6.1.4.1.318.1.1.10.4.7.2 | TablememSmokeSensorStatusTable | not-accessible | mandatory | Allows for the access of individual sensors. |
| 1.3.6.1.4.1.318.1.1.10.4.7.2.1 | RowmemSmokeSensorStatusEntry | not-accessible | mandatory | The sensor to access. |
| 1.3.6.1.4.1.318.1.1.10.4.7.2.1.1 | ColumnmemSmokeSensorStatusModuleIndex | read-only | mandatory | The index to the module entry. |
| 1.3.6.1.4.1.318.1.1.10.4.7.2.1.2 | ColumnmemSmokeSensorStatusSensorIndex | read-only | mandatory | The index to the sensor entry. |
| 1.3.6.1.4.1.318.1.1.10.4.7.2.1.3 | ColumnmemSmokeSensorStatusSensorName | read-only | mandatory | The user defined name of the smoke sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.7.2.1.4 | ColumnmemSmokeSensorStatusSensorLocation | read-only | mandatory | The user defined location of the smoke sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.7.2.1.5 | ColumnmemSmokeSensorStatusSensorState | read-only | mandatory | The state of the smoke sensor. smokeDetected (1) indicates there is smoke. noSmoke (2) indicates there is no smoke. unknown (3) indicates the state is unknown. |
| 1.3.6.1.4.1.318.1.1.10.4.7.2.1.6 | ColumnmemSmokeSensorStatusSensorSeverity | read-only | mandatory | The severity of the alarm that will be triggered when the smoke sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
| 1.3.6.1.4.1.318.1.1.10.4.7.2.1.7 | ColumnmemSmokeStatusAlarmStatus | read-only | mandatory | The alarm status of the smoke sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.7.2.1.8 | ColumnmemSmokeSensorCommStatus | read-only | mandatory | The communication status of the smoke sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.7.3 | ScalarmemVibrationSensorStatusTableSize | read-only | mandatory | The number of entries in the memVibrationSensorStatusTable. |
| 1.3.6.1.4.1.318.1.1.10.4.7.4 | TablememVibrationSensorStatusTable | not-accessible | mandatory | Allows for the access of individual sensors. |
| 1.3.6.1.4.1.318.1.1.10.4.7.4.1 | RowmemVibrationSensorStatusEntry | not-accessible | mandatory | The sensors to access. |
| 1.3.6.1.4.1.318.1.1.10.4.7.4.1.1 | ColumnmemVibrationSensorStatusModuleIndex | read-only | mandatory | The index to the sensor module entry. |
| 1.3.6.1.4.1.318.1.1.10.4.7.4.1.2 | ColumnmemVibrationSensorStatusSensorIndex | read-only | mandatory | The index to the sensor entry. |
| 1.3.6.1.4.1.318.1.1.10.4.7.4.1.3 | ColumnmemVibrationSensorStatusSensorName | read-only | mandatory | The user defined name of the vibration sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.7.4.1.4 | ColumnmemVibrationSensorStatusSensorLocation | read-only | mandatory | The user defined location of the vibration sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.7.4.1.5 | ColumnmemVibrationSensorStatusSensorState | read-only | mandatory | The state of the vibration sensor. vibrationDetected (1) indicates there is vibration. noVibration (2) indicates there is no vibration. unknown (3) indicates t… |
| 1.3.6.1.4.1.318.1.1.10.4.7.4.1.6 | ColumnmemVibrationSensorStatusSensorSeverity | read-only | mandatory | The severity of the alarm that will be triggered when the vibration sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
| 1.3.6.1.4.1.318.1.1.10.4.7.4.1.7 | ColumnmemVibrationStatusAlarmStatus | read-only | mandatory | The alarm status of the vibration sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.7.4.1.8 | ColumnmemVibrationSensorCommStatus | read-only | mandatory | The communication status of the vibration sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.7.5 | ScalarmemFluidSensorStatusTableSize | read-only | mandatory | The number of entries in the memFluidSensorStatusTable. |
| 1.3.6.1.4.1.318.1.1.10.4.7.6 | TablememFluidSensorStatusTable | not-accessible | mandatory | Allows for access of individual sensors. |
| 1.3.6.1.4.1.318.1.1.10.4.7.6.1 | RowmemFluidSensorStatusEntry | not-accessible | mandatory | The sensor to access. |
| 1.3.6.1.4.1.318.1.1.10.4.7.6.1.1 | ColumnmemFluidSensorStatusModuleIndex | read-only | mandatory | The index to the sensor module entry. |
| 1.3.6.1.4.1.318.1.1.10.4.7.6.1.2 | ColumnmemFluidSensorStatusSensorIndex | read-only | mandatory | The index to the sensor entry. |
| 1.3.6.1.4.1.318.1.1.10.4.7.6.1.3 | ColumnmemFluidSensorStatusSensorName | read-only | mandatory | The user defined name of the fluid sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.7.6.1.4 | ColumnmemFluidSensorStatusSensorLocation | read-only | mandatory | The user defined location of the fluid sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.7.6.1.5 | ColumnmemFluidSensorStatusSensorState | read-only | mandatory | The state of the fluid sensor. fluidDetected (1) indicates there is fluid leak. noFluid (2) indicates there is no fluid leak. unknown (3) indicates the state i… |
| 1.3.6.1.4.1.318.1.1.10.4.7.6.1.6 | ColumnmemFluidSensorStatusSensorSeverity | read-only | mandatory | The severity of the alarm that will be triggered when the fluid sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
| 1.3.6.1.4.1.318.1.1.10.4.7.6.1.7 | ColumnmemFluidStatusAlarmStatus | read-only | mandatory | The alarm status of the fluid sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.7.6.1.8 | ColumnmemFluidSensorCommStatus | read-only | mandatory | The communication status of the fluid sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.7.7 | ScalarmemDoorSensorStatusTableSize | read-only | mandatory | The number of entries in the memDoorSensorStatusTable. |
| 1.3.6.1.4.1.318.1.1.10.4.7.8 | TablememDoorSensorStatusTable | not-accessible | mandatory | Allows for the access of individual sensors. |
| 1.3.6.1.4.1.318.1.1.10.4.7.8.1 | RowmemDoorSensorStatusEntry | not-accessible | mandatory | The sensor to access. |
| 1.3.6.1.4.1.318.1.1.10.4.7.8.1.1 | ColumnmemDoorSensorStatusModuleIndex | read-only | mandatory | The index to the sensor module entry. |
| 1.3.6.1.4.1.318.1.1.10.4.7.8.1.2 | ColumnmemDoorSensorStatusSensorIndex | read-only | mandatory | The index to the sensor entry. |
| 1.3.6.1.4.1.318.1.1.10.4.7.8.1.3 | ColumnmemDoorSensorStatusSensorName | read-only | mandatory | The user defined name of the door sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.7.8.1.4 | ColumnmemDoorSensorStatusSensorLocation | read-only | mandatory | The user defined location of the door sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.7.8.1.5 | ColumnmemDoorSensorStatusSensorState | read-only | mandatory | The state of the door sensor. open (1) indicates door open. closed (2) indicates door closed. unknown (3) indicates the state is unknown. |
| 1.3.6.1.4.1.318.1.1.10.4.7.8.1.6 | ColumnmemDoorSensorStatusSensorSeverity | read-only | mandatory | The severity of the alarm that will be triggered when the door sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
| 1.3.6.1.4.1.318.1.1.10.4.7.8.1.7 | ColumnmemDoorStatusAlarmStatus | read-only | mandatory | The alarm status of the door sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.7.8.1.8 | ColumnmemDoorSensorCommStatus | read-only | mandatory | The communication status of the door sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.7.9 | TablememSmokeSensorConfigTable | not-accessible | mandatory | Allows for the configuration of individual sensors. |
| 1.3.6.1.4.1.318.1.1.10.4.7.9.1 | RowmemSmokeSensorConfigEntry | not-accessible | mandatory | The sensors to configure. |
| 1.3.6.1.4.1.318.1.1.10.4.7.9.1.1 | ColumnmemSmokeSensorConfigSensorModuleIndex | read-only | mandatory | The index to the sensor module entry. |
| 1.3.6.1.4.1.318.1.1.10.4.7.9.1.2 | ColumnmemSmokeSensorConfigSensorIndex | read-only | mandatory | The index to the sensor entry. |
| 1.3.6.1.4.1.318.1.1.10.4.7.9.1.3 | ColumnmemSmokeSensorConfigSensorName | read-write | mandatory | The user defined name of the smoke sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.7.9.1.4 | ColumnmemSmokeSensorConfigSensorLocation | read-write | mandatory | The user defined location of the smoke sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.7.9.1.5 | ColumnmemSmokeSensorConfigSensorSeverity | read-write | mandatory | The severity of the alarm that will be triggered when the smoke sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
| 1.3.6.1.4.1.318.1.1.10.4.7.9.1.6 | ColumnmemSmokeSensorConfigAlarmGeneration | read-write | mandatory | Enable or disable alarm generation on this input. |
| 1.3.6.1.4.1.318.1.1.10.4.7.10 | TablememVibrationSensorConfigTable | not-accessible | mandatory | Allows for the configuration of individual sensors. |
| 1.3.6.1.4.1.318.1.1.10.4.7.10.1 | RowmemVibrationSensorConfigEntry | not-accessible | mandatory | The sensor to configure. |
| 1.3.6.1.4.1.318.1.1.10.4.7.10.1.1 | ColumnmemVibrationSensorModuleConfigIndex | read-only | mandatory | The index to the sensor module entry. |
| 1.3.6.1.4.1.318.1.1.10.4.7.10.1.2 | ColumnmemVibrationSensorConfigSensorIndex | read-only | mandatory | The index to the sensor entry. |
| 1.3.6.1.4.1.318.1.1.10.4.7.10.1.3 | ColumnmemVibrationSensorConfigSensorName | read-write | mandatory | The user defined name of the vibration sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.7.10.1.4 | ColumnmemVibrationSensorConfigSensorLocation | read-write | mandatory | The user defined location of the vibration sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.7.10.1.5 | ColumnmemVibrationSensorConfigSensorSeverity | read-write | mandatory | The severity of the alarm that will be triggered when the vibration sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
| 1.3.6.1.4.1.318.1.1.10.4.7.10.1.6 | ColumnmemVibrationSensorConfigAlarmGeneration | read-write | mandatory | Enable or disable alarm generation on this input. |
| 1.3.6.1.4.1.318.1.1.10.4.7.11 | TablememFluidSensorConfigTable | not-accessible | mandatory | Allows for the configuration of individual sensors. |
| 1.3.6.1.4.1.318.1.1.10.4.7.11.1 | RowmemFluidSensorConfigEntry | not-accessible | mandatory | The sensor to configure. |
| 1.3.6.1.4.1.318.1.1.10.4.7.11.1.1 | ColumnmemFluidSensorModuleConfigIndex | read-only | mandatory | The index to the sensor module entry. |
| 1.3.6.1.4.1.318.1.1.10.4.7.11.1.2 | ColumnmemFluidSensorConfigSensorIndex | read-only | mandatory | The index to the sensor entry. |
| 1.3.6.1.4.1.318.1.1.10.4.7.11.1.3 | ColumnmemFluidSensorConfigSensorName | read-write | mandatory | The user defined name of the fluid sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.7.11.1.4 | ColumnmemFluidSensorConfigSensorLocation | read-write | mandatory | The user defined location of the fluid sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.7.11.1.5 | ColumnmemFluidSensorConfigSensorSeverity | read-write | mandatory | The severity of the alarm that will be triggered when the fluid sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
| 1.3.6.1.4.1.318.1.1.10.4.7.11.1.6 | ColumnmemFluidSensorConfigAlarmGeneration | read-write | mandatory | Enable or disable alarm generation on this input. |
| 1.3.6.1.4.1.318.1.1.10.4.7.12 | TablememDoorSensorConfigTable | not-accessible | mandatory | Allows for the configuration of individual sensors. |
| 1.3.6.1.4.1.318.1.1.10.4.7.12.1 | RowmemDoorSensorConfigEntry | not-accessible | mandatory | The sensors to configure. |
| 1.3.6.1.4.1.318.1.1.10.4.7.12.1.1 | ColumnmemDoorSensorModuleConfigIndex | read-only | mandatory | The index to the sensor module entry. |
| 1.3.6.1.4.1.318.1.1.10.4.7.12.1.2 | ColumnmemDoorSensorConfigSensorIndex | read-only | mandatory | The index to the sensor entry. |
| 1.3.6.1.4.1.318.1.1.10.4.7.12.1.3 | ColumnmemDoorSensorConfigSensorName | read-write | mandatory | The user defined name of the door sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.7.12.1.4 | ColumnmemDoorSensorConfigSensorLocation | read-write | mandatory | The user defined location of the door sensor. |
| 1.3.6.1.4.1.318.1.1.10.4.7.12.1.5 | ColumnmemDoorSensorConfigSensorSeverity | read-write | mandatory | The severity of the alarm that will be triggered when the door sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
| 1.3.6.1.4.1.318.1.1.10.4.7.12.1.6 | ColumnmemDoorSensorConfigAlarmGeneration | read-write | mandatory | Enable or disable alarm generation on this input. |
| 1.3.6.1.4.1.318.1.1.10.5 | NodeenvWireless | |||
| 1.3.6.1.4.1.318.1.1.10.5.1 | NodewirelessSensorStatus | |||
| 1.3.6.1.4.1.318.1.1.10.5.1.1 | TablewirelessSensorStatusTable | not-accessible | mandatory | Allows for the access of individual sensors. |
| 1.3.6.1.4.1.318.1.1.10.5.1.1.1 | RowwirelessSensorStatusEntry | not-accessible | mandatory | A list of wireless sensor status table entries. |
| 1.3.6.1.4.1.318.1.1.10.5.1.1.1.1 | ColumnwirelessSensorStatusIndex | read-only | mandatory | The index to the sensor entry. |
| 1.3.6.1.4.1.318.1.1.10.5.1.1.1.2 | ColumnwirelessSensorStatusExtAddr | read-only | mandatory | The extended address is the combination of the unique 10 byte MAC address of the sensor concatenated with its short address. |
| 1.3.6.1.4.1.318.1.1.10.5.1.1.1.3 | ColumnwirelessSensorStatusName | read-only | mandatory | The name of the wireless sensor. |
| 1.3.6.1.4.1.318.1.1.10.5.1.1.1.4 | ColumnwirelessSensorStatusAlarmGeneration | read-only | mandatory | Indicates whether alarm generation is enabled or disabled for the sensor. |
| 1.3.6.1.4.1.318.1.1.10.5.1.1.1.5 | ColumnwirelessSensorStatusTemperature | read-only | mandatory | The current temperature are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.5.1.1.1.6 | ColumnwirelessSensorStatusHighTempThresh | read-only | mandatory | Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.5.1.1.1.7 | ColumnwirelessSensorStatusLowTempThresh | read-only | mandatory | Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.5.1.1.1.8 | ColumnwirelessSensorStatusHumidity | read-only | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.1.1.1.9 | ColumnwirelessSensorStatusHighHumidityThresh | read-only | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.1.1.1.10 | ColumnwirelessSensorStatusLowHumidityThresh | read-only | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.1.1.1.11 | ColumnwirelessSensorStatusCommStatus | read-only | mandatory | The communication status of the wireless sensor. inactive(0) indicates sensor is in the wireless network but not sending information. active(1) indicates wirel… |
| 1.3.6.1.4.1.318.1.1.10.5.1.1.1.12 | ColumnwirelessSensorStatusMaxTempThresh | read-only | mandatory | Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.5.1.1.1.13 | ColumnwirelessSensorStatusMinTempThresh | read-only | mandatory | Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.5.1.1.1.14 | ColumnwirelessSensorStatusMaxHumidityThresh | read-only | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.1.1.1.15 | ColumnwirelessSensorStatusMinHumidityThresh | read-only | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.1.1.1.16 | ColumnwirelessSensorStatusBattery | read-only | mandatory | Values are displayed in tenths of Volts DC. |
| 1.3.6.1.4.1.318.1.1.10.5.1.1.1.17 | ColumnwirelessSensorStatusLowBatteryThresh | read-only | mandatory | Values are displayed in tenths of Volts DC. |
| 1.3.6.1.4.1.318.1.1.10.5.1.1.1.18 | ColumnwirelessSensorStatusMinBatteryThresh | read-only | mandatory | Values are displayed in tenths of Volts DC. |
| 1.3.6.1.4.1.318.1.1.10.5.1.1.1.19 | ColumnwirelessSensorStatusRssi | read-only | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.1.1.1.20 | ColumnwirelessSensorStatusLowRssiThresh | read-only | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.1.1.1.21 | ColumnwirelessSensorStatusMinRssiThresh | read-only | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.1.1.1.22 | ColumnwirelessSensorStatusLocation | read-only | mandatory | A user-defined string identifying the location of the wireless sensor. |
| 1.3.6.1.4.1.318.1.1.10.5.1.1.1.23 | ColumnwirelessSensorStatusAlarmStatus | read-only | mandatory | The alarm status of the wireless sensor. This integer should be interpreted as a bit map, with each bit representing the presence or absence of the specific al… |
| 1.3.6.1.4.1.318.1.1.10.5.2 | NodewirelessSensorPodStatus | |||
| 1.3.6.1.4.1.318.1.1.10.5.2.1 | TablewirelessSensorPodStatusTable | not-accessible | mandatory | Allows for the access of individual pod sensors. |
| 1.3.6.1.4.1.318.1.1.10.5.2.1.1 | RowwirelessSensorPodStatusEntry | not-accessible | mandatory | The sensor pod to access. |
| 1.3.6.1.4.1.318.1.1.10.5.2.1.1.1 | ColumnwirelessSensorPodStatusIndex | read-only | mandatory | The index to the pod sensor entry. |
| 1.3.6.1.4.1.318.1.1.10.5.2.1.1.2 | ColumnwirelessSensorPodPortIndex | read-only | mandatory | The pod sensor port index. |
| 1.3.6.1.4.1.318.1.1.10.5.2.1.1.3 | ColumnwirelessSensorPodStatusExtAddr | read-only | mandatory | The extended address is the combination of the unique 10 byte MAC address of the sensor concatenated with its short address. |
| 1.3.6.1.4.1.318.1.1.10.5.2.1.1.4 | ColumnwirelessSensorPodStatusName | read-only | mandatory | The name of the sensor pod. |
| 1.3.6.1.4.1.318.1.1.10.5.2.1.1.5 | ColumnwirelessSensorPodStatusAlarmGeneration | read-only | mandatory | Status of whether alarm generation is enabled or disabled. |
| 1.3.6.1.4.1.318.1.1.10.5.2.1.1.6 | ColumnwirelessSensorPodStatusTemperature | read-only | mandatory | Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.5.2.1.1.7 | ColumnwirelessSensorPodStatusHighTempThresh | read-only | mandatory | Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.5.2.1.1.8 | ColumnwirelessSensorPodStatusLowTempThresh | read-only | mandatory | Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.5.2.1.1.9 | ColumnwirelessSensorPodStatusHumidity | read-only | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.2.1.1.10 | ColumnwirelessSensorPodStatusHighHumidityThresh | read-only | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.2.1.1.11 | ColumnwirelessSensorPodStatusLowHumidityThresh | read-only | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.2.1.1.12 | ColumnwirelessSensorPodStatusCommStatus | read-only | mandatory | The communication status of the wireless sensor. inactive(0) indicates pod sensor is in the wireless network but not sending information. active(1) indicates w… |
| 1.3.6.1.4.1.318.1.1.10.5.2.1.1.13 | ColumnwirelessSensorPodStatusMaxTempThresh | read-only | mandatory | Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.5.2.1.1.14 | ColumnwirelessSensorPodStatusMinTempThresh | read-only | mandatory | Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.5.2.1.1.15 | ColumnwirelessSensorPodStatusMaxHumidityThresh | read-only | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.2.1.1.16 | ColumnwirelessSensorPodStatusMinHumidityThresh | read-only | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.2.1.1.17 | ColumnwirelessSensorPodStatusDryContactState | read-only | mandatory | State of the dry contact. If the dry contact is closed, the drycontactClosed (1) value will be returned. If the dry contact state is open, the drycontactOpen (… |
| 1.3.6.1.4.1.318.1.1.10.5.2.1.1.18 | ColumnwirelessSensorPodStatusDryContactNormalState | read-only | mandatory | The normal state of the dry contact. If the normal state is closed, the normallyClosed (1) value will be returned. If the normal state is open, the normallyOpe… |
| 1.3.6.1.4.1.318.1.1.10.5.2.1.1.19 | ColumnwirelessSensorPodStatusBattery | read-only | mandatory | Values are displayed in tenths of Volts DC. |
| 1.3.6.1.4.1.318.1.1.10.5.2.1.1.20 | ColumnwirelessSensorPodStatusLowBatteryThresh | read-only | mandatory | Values are displayed in tenths of Volts DC. |
| 1.3.6.1.4.1.318.1.1.10.5.2.1.1.21 | ColumnwirelessSensorPodStatusMinBatteryThresh | read-only | mandatory | Values are displayed in tenths of Volts DC. |
| 1.3.6.1.4.1.318.1.1.10.5.2.1.1.22 | ColumnwirelessSensorPodStatusRssi | read-only | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.2.1.1.23 | ColumnwirelessSensorPodStatusLowRssiThresh | read-only | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.2.1.1.24 | ColumnwirelessSensorPodStatusMinRssiThresh | read-only | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.2.1.1.25 | ColumnwirelessSensorPodStatusLocation | read-only | mandatory | The location of the wireless sensor pod. |
| 1.3.6.1.4.1.318.1.1.10.5.2.1.1.26 | ColumnwirelessSensorPodStatusAlarmStatus | read-only | mandatory | The alarm status of the wireless pod sensor. This integer should be interpreted as a bit map, with each bit representing the presence or absence of the specifi… |
| 1.3.6.1.4.1.318.1.1.10.5.3 | NodewirelessSensorConfig | |||
| 1.3.6.1.4.1.318.1.1.10.5.3.1 | TablewirelessSensorConfigTable | not-accessible | mandatory | Allows for the configuration of individual sensors. |
| 1.3.6.1.4.1.318.1.1.10.5.3.1.1 | RowwirelessSensorConfigEntry | not-accessible | mandatory | The sensor to configure. |
| 1.3.6.1.4.1.318.1.1.10.5.3.1.1.1 | ColumnwirelessSensorConfigIndex | read-only | mandatory | The index to the entry. |
| 1.3.6.1.4.1.318.1.1.10.5.3.1.1.2 | ColumnwirelessSensorConfigName | read-write | mandatory | The user-defined wireless sensor ID string. |
| 1.3.6.1.4.1.318.1.1.10.5.3.1.1.3 | ColumnwirelessSensorConfigAlarmGeneration | read-write | mandatory | Enable or disable alarm generation for this sensor. |
| 1.3.6.1.4.1.318.1.1.10.5.3.1.1.4 | ColumnwirelessSensorConfigHighTempThresh | read-write | mandatory | Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.5.3.1.1.5 | ColumnwirelessSensorConfigLowTempThresh | read-write | mandatory | Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.5.3.1.1.6 | ColumnwirelessSensorConfigHighHumidityThresh | read-write | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.3.1.1.7 | ColumnwirelessSensorConfigLowHumidityThresh | read-write | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.3.1.1.8 | ColumnwirelessSensorConfigMaxTempThresh | read-write | mandatory | Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.5.3.1.1.9 | ColumnwirelessSensorConfigMinTempThresh | read-write | mandatory | Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.5.3.1.1.10 | ColumnwirelessSensorConfigMaxHumidityThresh | read-write | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.3.1.1.11 | ColumnwirelessSensorConfigMinHumidityThresh | read-write | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.3.1.1.12 | ColumnwirelessSensorConfigLowBatteryThresh | read-write | mandatory | Values are displayed in tenths of Volts DC. |
| 1.3.6.1.4.1.318.1.1.10.5.3.1.1.13 | ColumnwirelessSensorConfigMinBatteryThresh | read-write | mandatory | Values are displayed in tenths of Volts DC. |
| 1.3.6.1.4.1.318.1.1.10.5.3.1.1.14 | ColumnwirelessSensorConfigLowRssiThresh | read-write | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.3.1.1.15 | ColumnwirelessSensorConfigMinRssiThresh | read-write | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.3.1.1.16 | ColumnwirelessSensorConfigLocation | read-write | mandatory | A user-defined string identifying the location of the wireless sensor. Maximum text input is 20 characters. |
| 1.3.6.1.4.1.318.1.1.10.5.4 | NodewirelessSensorPodConfig | |||
| 1.3.6.1.4.1.318.1.1.10.5.4.1 | TablewirelessSensorPodConfigTable | not-accessible | mandatory | Allows for the configuration of individual sensors. |
| 1.3.6.1.4.1.318.1.1.10.5.4.1.1 | RowwirelessSensorPodConfigEntry | not-accessible | mandatory | The sensor to configure. |
| 1.3.6.1.4.1.318.1.1.10.5.4.1.1.1 | ColumnwirelessSensorPodConfigIndex | read-only | mandatory | The index to the entry. |
| 1.3.6.1.4.1.318.1.1.10.5.4.1.1.2 | ColumnwirelessSensorPodConfigPortIndex | read-only | mandatory | The sensor pod port index. |
| 1.3.6.1.4.1.318.1.1.10.5.4.1.1.3 | ColumnwirelessSensorPodConfigName | read-write | mandatory | The user defined name of the sensor pod. |
| 1.3.6.1.4.1.318.1.1.10.5.4.1.1.4 | ColumnwirelessSensorPodConfigAlarmGeneration | read-write | mandatory | Enable or disable alarm generation for this sensor. |
| 1.3.6.1.4.1.318.1.1.10.5.4.1.1.5 | ColumnwirelessSensorPodConfigDryContactNormalState | read-write | mandatory | The normal state of the dry contact. If the normal state is closed, the normallyClosed (1) value will be returned. If the normal state is open, the normallyOpe… |
| 1.3.6.1.4.1.318.1.1.10.5.4.1.1.6 | ColumnwirelessSensorPodConfigHighTempThresh | read-write | mandatory | Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.5.4.1.1.7 | ColumnwirelessSensorPodConfigLowTempThresh | read-write | mandatory | Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.5.4.1.1.8 | ColumnwirelessSensorPodConfigHighHumidityThresh | read-write | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.4.1.1.9 | ColumnwirelessSensorPodConfigLowHumidityThresh | read-write | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.4.1.1.10 | ColumnwirelessSensorPodConfigMaxTempThresh | read-write | mandatory | Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.5.4.1.1.11 | ColumnwirelessSensorPodConfigMinTempThresh | read-write | mandatory | Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
| 1.3.6.1.4.1.318.1.1.10.5.4.1.1.12 | ColumnwirelessSensorPodConfigMaxHumidityThresh | read-write | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.4.1.1.13 | ColumnwirelessSensorPodConfigMinHumidityThresh | read-write | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.4.1.1.14 | ColumnwirelessSensorPodConfigLowBatteryThresh | read-write | mandatory | Values are displayed in tenths of Volts DC. |
| 1.3.6.1.4.1.318.1.1.10.5.4.1.1.15 | ColumnwirelessSensorPodConfigMinBatteryThresh | read-write | mandatory | Values are displayed in tenths of Volts DC. |
| 1.3.6.1.4.1.318.1.1.10.5.4.1.1.16 | ColumnwirelessSensorPodConfigLowRssiThresh | read-write | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.4.1.1.17 | ColumnwirelessSensorPodConfigMinRssiThresh | read-write | mandatory | Values are represented in whole number percentage. |
| 1.3.6.1.4.1.318.1.1.10.5.4.1.1.18 | ColumnwirelessSensorPodConfigLocation | read-write | mandatory | A user-defined string identifying the location of the wireless pod sensor. Maximum text input is 20 characters. |
| 1.3.6.1.4.1.318.1.1.11 | Nodenetlock | |||
| 1.3.6.1.4.1.318.1.1.11.1 | NodenlIdent | |||
| 1.3.6.1.4.1.318.1.1.11.2 | NodenlStatus | |||
| 1.3.6.1.4.1.318.1.1.12 | NoderPDU | |||
| 1.3.6.1.4.1.318.1.1.12.1 | NoderPDUIdent | |||
| 1.3.6.1.4.1.318.1.1.12.1.1 | ScalarrPDUIdentName | read-write | mandatory | The name of the Rack PDU. The maximum string size is device dependent. |
| 1.3.6.1.4.1.318.1.1.12.1.2 | ScalarrPDUIdentHardwareRev | read-only | mandatory | The hardware revision of the Rack PDU. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.12.1.3 | ScalarrPDUIdentFirmwareRev | read-only | mandatory | An 8-byte ID string identifying the Rack PDU firmware revision. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.12.1.4 | ScalarrPDUIdentDateOfManufacture | read-only | mandatory | The date when the Rack PDU was manufactured in mm/dd/yyyy format. This value is set at the factory. The year 2000 will be represented by 00. |
| 1.3.6.1.4.1.318.1.1.12.1.5 | ScalarrPDUIdentModelNumber | read-only | mandatory | A 10-character string identifying the model number of the Rack PDU. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.12.1.6 | ScalarrPDUIdentSerialNumber | read-only | mandatory | A 12-character string identifying the serial number of the Rack PDU. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.12.1.7 | ScalarrPDUIdentDeviceRating | read-only | mandatory | Getting this OID will return the electrical rating of the device in Amps. |
| 1.3.6.1.4.1.318.1.1.12.1.8 | ScalarrPDUIdentDeviceNumOutlets | read-only | mandatory | Getting this OID will return the number of outlets contained in the device. |
| 1.3.6.1.4.1.318.1.1.12.1.9 | ScalarrPDUIdentDeviceNumPhases | read-only | mandatory | Getting this OID will return the number of phases supported by the device. |
| 1.3.6.1.4.1.318.1.1.12.1.10 | ScalarrPDUIdentDeviceNumBreakers | read-only | mandatory | Getting this OID will return the number of circuit breakers supported by the device. This is the same as the number of banks of outlets. 0 will be returned if … |
| 1.3.6.1.4.1.318.1.1.12.1.11 | ScalarrPDUIdentDeviceBreakerRating | read-only | mandatory | Getting this OID will return rating of the circuit breakers on the device in Amps if it has any. |
| 1.3.6.1.4.1.318.1.1.12.1.12 | ScalarrPDUIdentDeviceOrientation | read-only | mandatory | Getting this OID will return the intended physical orientation of the device. OrientHorizonatal(1) indicates Horizontal. OrientVertical(2) indicates Vertical. |
| 1.3.6.1.4.1.318.1.1.12.1.13 | ScalarrPDUIdentDeviceOutletLayout | read-only | mandatory | Getting this OID will return outlet layout for the device. seqPhaseToNeutral(1) indicates outlet layout as follows: 1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,... seqPhaseT… |
| 1.3.6.1.4.1.318.1.1.12.1.14 | ScalarrPDUIdentDeviceDisplayOrientation | read-write | mandatory | Getting this OID will return the intended physical orientation of the Seven-Segment Display. Normal(1) indicates Normal. Reverse(2)indicates Upside-Down. |
| 1.3.6.1.4.1.318.1.1.12.1.15 | ScalarrPDUIdentDeviceLinetoLineVoltage | read-write | mandatory | Getting/Setting this OID will return/set the Line to Line Voltage. This OID defaults to the nominal input line voltage in volts AC. This setting is used to cal… |
| 1.3.6.1.4.1.318.1.1.12.1.16 | ScalarrPDUIdentDevicePowerWatts | read-only | mandatory | Getting this OID will return the Power in Watts. |
| 1.3.6.1.4.1.318.1.1.12.1.17 | ScalarrPDUIdentDevicePowerFactor | read-write | mandatory | Getting/setting this OID will return/set the Power Factor in thousanths (1000 is power factor of 1). For AP8XXX SKUs, this OID is read-only Valid range is from… |
| 1.3.6.1.4.1.318.1.1.12.1.18 | ScalarrPDUIdentDevicePowerVA | read-only | mandatory | Getting this OID will return the Power in VA. |
| 1.3.6.1.4.1.318.1.1.12.1.19 | ScalarrPDUIdentDeviceLinetoNeutralVoltage | read-write | mandatory | Getting/Setting this OID will return/set the Line to Neutral Voltage. This OID defaults to the nominal line to neutral voltage in volts AC. This setting is use… |
| 1.3.6.1.4.1.318.1.1.12.2 | NoderPDULoad | |||
| 1.3.6.1.4.1.318.1.1.12.2.1 | NoderPDULoadDevice | |||
| 1.3.6.1.4.1.318.1.1.12.2.1.1 | ScalarrPDULoadDevMaxPhaseLoad | read-only | mandatory | Getting this OID will return the maximum rated power that each phase of the Rack PDU can provide. It is represented in Amps. 0 will be returned if the unit is … |
| 1.3.6.1.4.1.318.1.1.12.2.1.2 | ScalarrPDULoadDevNumPhases | read-only | mandatory | The number of phases available with this Rack PDU. |
| 1.3.6.1.4.1.318.1.1.12.2.1.3 | ScalarrPDULoadDevMaxBankLoad | read-only | mandatory | Getting this OID will return the maximum rated power that a bank of the Rack PDU can provide. It is represented in Amps. 0 will be returned if the device does … |
| 1.3.6.1.4.1.318.1.1.12.2.1.4 | ScalarrPDULoadDevNumBanks | read-only | mandatory | The number of banks of outlets available with this Rack PDU. A bank of outlets has a unique circuit breaker for a subset of the total number of outlets on the … |
| 1.3.6.1.4.1.318.1.1.12.2.1.5 | ScalarrPDULoadDevBankTableSize | read-only | mandatory | The size of the Bank Table. |
| 1.3.6.1.4.1.318.1.1.12.2.1.6 | TablerPDULoadDevBankTable | not-accessible | mandatory | Allows for getting the Bank Max Load in the Rack PDU. |
| 1.3.6.1.4.1.318.1.1.12.2.1.6.1 | RowrPDULoadDevBankEntry | not-accessible | mandatory | The Rack PDU Banks Access. |
| 1.3.6.1.4.1.318.1.1.12.2.1.6.1.1 | ColumnrPDULoadDevBankIndex | read-only | mandatory | The index to the Rack PDU bank entry. |
| 1.3.6.1.4.1.318.1.1.12.2.1.6.1.2 | ColumnrPDULoadDevBankNumber | read-only | mandatory | Getting this OID will return the bank number. |
| 1.3.6.1.4.1.318.1.1.12.2.1.6.1.3 | ColumnrPDULoadDevBankMaxLoad | read-only | mandatory | Getting this OID will return the maximum rated power that each bank of the Rack PDU can provide. It is represented in Amps. |
| 1.3.6.1.4.1.318.1.1.12.2.1.7 | ScalarrPDULoadDevMaxOutletTableSize | read-only | mandatory | The size of the Outlet Table. |
| 1.3.6.1.4.1.318.1.1.12.2.1.8 | TablerPDULoadDevMaxOutletTable | not-accessible | mandatory | Allows for getting the Max Outlet Load in an Outlet Monitored Rack PDU. |
| 1.3.6.1.4.1.318.1.1.12.2.1.8.1 | RowrPDULoadDevMaxOutletEntry | not-accessible | mandatory | This gives access to Max Outlet Load of an Outlet Monitored Rack PDU |
| 1.3.6.1.4.1.318.1.1.12.2.1.8.1.1 | ColumnrPDULoadDevOutletIndex | read-only | mandatory | The index to the Outlet Monitored Rack PDU Max Outlet Load entry. |
| 1.3.6.1.4.1.318.1.1.12.2.1.8.1.2 | ColumnrPDULoadDevOutletNumber | read-only | mandatory | Getting this OID will return the Outlet number. |
| 1.3.6.1.4.1.318.1.1.12.2.1.8.1.3 | ColumnrPDULoadDevMaxOutletLoad | read-only | mandatory | Getting this OID will return the maximum rated power that each Outlet of an Outlet Monitored Rack PDU can provide. It is represented in Amps. |
| 1.3.6.1.4.1.318.1.1.12.2.2 | NoderPDULoadPhaseConfig | |||
| 1.3.6.1.4.1.318.1.1.12.2.2.1 | TablerPDULoadPhaseConfigTable | not-accessible | mandatory | Allows for configuration of each Rack PDU phase. The number of entries is contained in the rPDULoadDevNumPhases OID. |
| 1.3.6.1.4.1.318.1.1.12.2.2.1.1 | RowrPDULoadPhaseConfigEntry | not-accessible | mandatory | The Rack PDU phase to configure. |
| 1.3.6.1.4.1.318.1.1.12.2.2.1.1.1 | ColumnrPDULoadPhaseConfigIndex | read-only | mandatory | The index to the Rack PDU phase entry. |
| 1.3.6.1.4.1.318.1.1.12.2.2.1.1.2 | ColumnrPDULoadPhaseConfigLowLoadThreshold | read-write | mandatory | A threshold that indicates the power consumption of the load is nearing a low consumption condition. It is represented in Amps. A warning will be issued when t… |
| 1.3.6.1.4.1.318.1.1.12.2.2.1.1.3 | ColumnrPDULoadPhaseConfigNearOverloadThreshold | read-write | mandatory | A threshold that indicates the power consumption of the load is nearing an overload condition. It is represented in Amps. A warning will be issued when the loa… |
| 1.3.6.1.4.1.318.1.1.12.2.2.1.1.4 | ColumnrPDULoadPhaseConfigOverloadThreshold | read-write | mandatory | A threshold that indicates the power consumption of the load has entered an overload condition. It is represented in Amps. A warning will be issued when the lo… |
| 1.3.6.1.4.1.318.1.1.12.2.2.1.1.5 | ColumnrPDULoadPhaseConfigAlarm | read-only | mandatory | Getting this OID will return the current Phase Alarm. |
| 1.3.6.1.4.1.318.1.1.12.2.3 | NoderPDULoadStatus | |||
| 1.3.6.1.4.1.318.1.1.12.2.3.1 | TablerPDULoadStatusTable | not-accessible | mandatory | Allows for getting of status of each Rack PDU phase/bank. The number of entries is calculated by adding the number of phases (rPDULoadDevNumPhases OID) and the… |
| 1.3.6.1.4.1.318.1.1.12.2.3.1.1 | RowrPDULoadStatusEntry | not-accessible | mandatory | The Rack PDU phase/bank to gather status from. |
| 1.3.6.1.4.1.318.1.1.12.2.3.1.1.1 | ColumnrPDULoadStatusIndex | read-only | mandatory | The index to the Rack PDU phase/bank entry. All phase information will precede any bank information |
| 1.3.6.1.4.1.318.1.1.12.2.3.1.1.2 | ColumnrPDULoadStatusLoad | read-only | mandatory | Getting this OID will return the phase/bank load measured in tenths of Amps. |
| 1.3.6.1.4.1.318.1.1.12.2.3.1.1.3 | ColumnrPDULoadStatusLoadState | read-only | mandatory | Getting this OID will return the phase/bank load state. phaseLoadNormal(1) indicates that the phase/bank is operating properly within the rPDULoadConfigLowLoad… |
| 1.3.6.1.4.1.318.1.1.12.2.3.1.1.4 | ColumnrPDULoadStatusPhaseNumber | read-only | mandatory | The phase number to which this record refers. |
| 1.3.6.1.4.1.318.1.1.12.2.3.1.1.5 | ColumnrPDULoadStatusBankNumber | read-only | mandatory | The bank number to which this record refers. A value of 0 will be returned if any bank is not present or if it is phase related. |
| 1.3.6.1.4.1.318.1.1.12.2.4 | NoderPDULoadBankConfig | |||
| 1.3.6.1.4.1.318.1.1.12.2.4.1 | TablerPDULoadBankConfigTable | not-accessible | mandatory | Allows for configuration of each Rack PDU bank. The number of entries is contained in the rPDULoadDevNumBanks OID. |
| 1.3.6.1.4.1.318.1.1.12.2.4.1.1 | RowrPDULoadBankConfigEntry | not-accessible | mandatory | The Rack PDU bank to configure. |
| 1.3.6.1.4.1.318.1.1.12.2.4.1.1.1 | ColumnrPDULoadBankConfigIndex | read-only | mandatory | The index to the Rack PDU bank entry. |
| 1.3.6.1.4.1.318.1.1.12.2.4.1.1.2 | ColumnrPDULoadBankConfigLowLoadThreshold | read-write | mandatory | A threshold that indicates the power consumption of the load is nearing a low consumption condition. It is represented in Amps. A warning will be issued when t… |
| 1.3.6.1.4.1.318.1.1.12.2.4.1.1.3 | ColumnrPDULoadBankConfigNearOverloadThreshold | read-write | mandatory | A threshold that indicates the power consumption of the load is nearing an overload condition. It is represented in Amps. A warning will be issued when the loa… |
| 1.3.6.1.4.1.318.1.1.12.2.4.1.1.4 | ColumnrPDULoadBankConfigOverloadThreshold | read-write | mandatory | A threshold that indicates the power consumption of the load has entered an overload condition. It is represented in Amps. A warning will be issued when the lo… |
| 1.3.6.1.4.1.318.1.1.12.2.4.1.1.5 | ColumnrPDULoadBankConfigAlarm | read-only | mandatory | Getting this OID will return the current Bank Alarm. |
| 1.3.6.1.4.1.318.1.1.12.3 | NoderPDUOutlet | |||
| 1.3.6.1.4.1.318.1.1.12.3.1 | NoderPDUOutletDevice | |||
| 1.3.6.1.4.1.318.1.1.12.3.1.1 | ScalarrPDUOutletDevCommand | read-write | mandatory | Setting this OID to immediateAllOn (2) will turn all outlets on immediately. Setting this OID to immediateAllOff (3) will turn all outlets off immediately. Set… |
| 1.3.6.1.4.1.318.1.1.12.3.1.2 | ScalarrPDUOutletDevColdstartDelay | read-write | mandatory | The amount of delay, in seconds, between when power is provided to the Switched Rack PDU and when the Switched Rack PDU provides basic master power to the outl… |
| 1.3.6.1.4.1.318.1.1.12.3.1.3 | ScalarrPDUOutletDevNumCntrlOutlets | read-only | mandatory | The number of controlled outlets on this Switched Rack PDU. |
| 1.3.6.1.4.1.318.1.1.12.3.1.4 | ScalarrPDUOutletDevNumTotalOutlets | read-only | mandatory | The total number of outlets on this Rack PDU. |
| 1.3.6.1.4.1.318.1.1.12.3.1.5 | ScalarrPDUOutletDevMonitoredOutlets | read-only | mandatory | The total number of monitored outlets on this Rack PDU. |
| 1.3.6.1.4.1.318.1.1.12.3.2 | NoderPDUOutletPhase | |||
| 1.3.6.1.4.1.318.1.1.12.3.2.1 | TablerPDUOutletPhaseTable | not-accessible | mandatory | Allows for management of outlets on a per phase basis. |
| 1.3.6.1.4.1.318.1.1.12.3.2.1.1 | RowrPDUOutletPhaseEntry | not-accessible | mandatory | The phase to manage. |
| 1.3.6.1.4.1.318.1.1.12.3.2.1.1.1 | ColumnrPDUOutletPhaseIndex | read-only | mandatory | The index to the Switched Rack PDU phase entry. |
| 1.3.6.1.4.1.318.1.1.12.3.2.1.1.2 | ColumnrPDUOutletPhaseOverloadRestriction | read-write | mandatory | This OID controls the behavior of a Switched Rack PDU phase when an overload condition is possible and additional outlets are requested to be turned on. Settin… |
| 1.3.6.1.4.1.318.1.1.12.3.3 | NoderPDUOutletControl | |||
| 1.3.6.1.4.1.318.1.1.12.3.3.1 | TablerPDUOutletControlTable | not-accessible | mandatory | Allows for control of the individual outlets. The number of entries is contained in the rPDUOutletDevNumCntrlOutlets OID. |
| 1.3.6.1.4.1.318.1.1.12.3.3.1.1 | RowrPDUOutletControlEntry | not-accessible | mandatory | The outlet to control. |
| 1.3.6.1.4.1.318.1.1.12.3.3.1.1.1 | ColumnrPDUOutletControlIndex | read-only | mandatory | The index to the outlet entry. |
| 1.3.6.1.4.1.318.1.1.12.3.3.1.1.2 | ColumnrPDUOutletControlOutletName | read-only | mandatory | The name of the outlet. The maximum string size is device dependent. An error will be returned if the set request exceeds the max size. This OID is provided fo… |
| 1.3.6.1.4.1.318.1.1.12.3.3.1.1.3 | ColumnrPDUOutletControlOutletPhase | read-only | mandatory | The phase/s associated with this outlet. For single phase devices, this object will always return phase1(1). For 3-phase devices, this object will return phase… |
| 1.3.6.1.4.1.318.1.1.12.3.3.1.1.4 | ColumnrPDUOutletControlOutletCommand | read-write | mandatory | Getting this variable will return the outlet state. If the outlet is on, the immediateOn (1) value will be returned. If the outlet is off, the immediateOff (2)… |
| 1.3.6.1.4.1.318.1.1.12.3.3.1.1.5 | ColumnrPDUOutletControlOutletBank | read-only | mandatory | The bank associated with this outlet. |
| 1.3.6.1.4.1.318.1.1.12.3.4 | NoderPDUOutletConfig | |||
| 1.3.6.1.4.1.318.1.1.12.3.4.1 | TablerPDUOutletConfigTable | not-accessible | mandatory | Allows for configuration of individual outlets. The number of entries is contained in the rPDUOutletDevNumCntrlOutlets OID. |
| 1.3.6.1.4.1.318.1.1.12.3.4.1.1 | RowrPDUOutletConfigEntry | not-accessible | mandatory | The outlet to configure. |
| 1.3.6.1.4.1.318.1.1.12.3.4.1.1.1 | ColumnrPDUOutletConfigIndex | read-only | mandatory | The index to the outlet entry. |
| 1.3.6.1.4.1.318.1.1.12.3.4.1.1.2 | ColumnrPDUOutletConfigOutletName | read-write | mandatory | The name of the outlet. The maximum string size is device dependent. An error will be returned if the set request exceeds the max size. |
| 1.3.6.1.4.1.318.1.1.12.3.4.1.1.3 | ColumnrPDUOutletConfigOutletPhase | read-only | mandatory | The phase/s associated with this outlet. For single phase devices, this object will always return phase1(1). For 3-phase devices, this object will return phase… |
| 1.3.6.1.4.1.318.1.1.12.3.4.1.1.4 | ColumnrPDUOutletConfigPowerOnTime | read-write | mandatory | The amount of time (in seconds) the outlet will delay powering on at coldstart or when a command that requires a turn-on delay is issued. Allowed values are: -… |
| 1.3.6.1.4.1.318.1.1.12.3.4.1.1.5 | ColumnrPDUOutletConfigPowerOffTime | read-write | mandatory | The amount of time (in seconds) the outlet will delay powering off when a command that requires a turn-off delay is issued. Allowed values are: -1 - never powe… |
| 1.3.6.1.4.1.318.1.1.12.3.4.1.1.6 | ColumnrPDUOutletConfigRebootDuration | read-write | mandatory | During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait, in seconds, after turning the power off, at the st… |
| 1.3.6.1.4.1.318.1.1.12.3.4.1.1.7 | ColumnrPDUOutletConfigOutletBank | read-only | mandatory | The bank associated with this outlet. |
| 1.3.6.1.4.1.318.1.1.12.3.4.2 | ScalarrPDUOutletConfigMonitoredTableSize | read-only | mandatory | The size of the Outlet Config Monitored Table |
| 1.3.6.1.4.1.318.1.1.12.3.4.3 | TablerPDUOutletConfigMonitoredTable | not-accessible | mandatory | Allows for getting/setting of outlet thresholds of an Outlet Monitored Rack PDU. |
| 1.3.6.1.4.1.318.1.1.12.3.4.3.1 | RowrPDUOutletConfigMonitoredEntry | not-accessible | mandatory | This gives access to Monitored Outlet entries |
| 1.3.6.1.4.1.318.1.1.12.3.4.3.1.1 | ColumnrPDUOutletConfigMonitoredIndex | read-only | mandatory | The index to the RACK PDU Phase entry. |
| 1.3.6.1.4.1.318.1.1.12.3.4.3.1.2 | ColumnrPDUOutletConfigMonitoredName | read-write | mandatory | The name of the Monitored Outlet. The maximum string size is device dependent. An error will be returned if the set request exceeds the max size. |
| 1.3.6.1.4.1.318.1.1.12.3.4.3.1.3 | ColumnrPDUOutletConfigMonitoredNumber | read-only | mandatory | The outlet number of an Outlet Monitored RACK PDU. |
| 1.3.6.1.4.1.318.1.1.12.3.4.3.1.4 | ColumnrPDUOutletConfigMonitoredLowLoadThreshold | read-write | mandatory | A threshold that indicates the power consumption of the load is nearing a low consumption condition. It is represented in Amps. A warning will be issued when t… |
| 1.3.6.1.4.1.318.1.1.12.3.4.3.1.5 | ColumnrPDUOutletConfigMonitoredNearOverloadThreshold | read-write | mandatory | A threshold that indicates the power consumption of the load is nearing an overload condition. It is represented in Amps. A warning will be issued when the loa… |
| 1.3.6.1.4.1.318.1.1.12.3.4.3.1.6 | ColumnrPDUOutletConfigMonitoredOverloadThreshold | read-write | mandatory | A threshold that indicates the power consumption of the load has entered an overload condition. It is represented in Amps. A warning will be issued when the lo… |
| 1.3.6.1.4.1.318.1.1.12.3.5 | NoderPDUOutletStatus | |||
| 1.3.6.1.4.1.318.1.1.12.3.5.1 | TablerPDUOutletStatusTable | not-accessible | mandatory | Allows for getting of status of individual outlets. The number of entries is contained in the rPDUOutletDevNumCntrlOutlets OID or rPDUOutletDevMonitoredOutlets… |
| 1.3.6.1.4.1.318.1.1.12.3.5.1.1 | RowrPDUOutletStatusEntry | not-accessible | mandatory | The outlet to gather status from. |
| 1.3.6.1.4.1.318.1.1.12.3.5.1.1.1 | ColumnrPDUOutletStatusIndex | read-only | mandatory | The index to the outlet entry. |
| 1.3.6.1.4.1.318.1.1.12.3.5.1.1.2 | ColumnrPDUOutletStatusOutletName | read-only | mandatory | The name of the outlet. The maximum string size is device dependent. This OID is provided for informational purposes only. |
| 1.3.6.1.4.1.318.1.1.12.3.5.1.1.3 | ColumnrPDUOutletStatusOutletPhase | read-only | mandatory | The phase/s associated with this outlet. For single phase devices, this object will always return phase1(1). For 3-phase devices, this object will return phase… |
| 1.3.6.1.4.1.318.1.1.12.3.5.1.1.4 | ColumnrPDUOutletStatusOutletState | read-only | mandatory | Getting this variable will return the outlet state. If the outlet is on, the outletStatusOn (1) value will be returned. If the outlet is off, the outletStatusO… |
| 1.3.6.1.4.1.318.1.1.12.3.5.1.1.5 | ColumnrPDUOutletStatusCommandPending | read-only | mandatory | Getting this variable will return the command pending state of the outlet. If a command is pending on the outlet, the outletStatusCommandPending (1) value will… |
| 1.3.6.1.4.1.318.1.1.12.3.5.1.1.6 | ColumnrPDUOutletStatusOutletBank | read-only | mandatory | The bank associated with this outlet. |
| 1.3.6.1.4.1.318.1.1.12.3.5.1.1.7 | ColumnrPDUOutletStatusLoad | read-only | mandatory | Getting this OID will return the measured Outlet load for an Outlet Monitored Rack PDU in tenths of Amps. For other models this OID is not supported. |
| 1.3.6.1.4.1.318.1.1.12.3.6 | NoderPDUOutletBank | |||
| 1.3.6.1.4.1.318.1.1.12.3.6.1 | TablerPDUOutletBankTable | not-accessible | mandatory | Allows for management of outlets on a per bank basis. |
| 1.3.6.1.4.1.318.1.1.12.3.6.1.1 | RowrPDUOutletBankEntry | not-accessible | mandatory | The bank to manage. |
| 1.3.6.1.4.1.318.1.1.12.3.6.1.1.1 | ColumnrPDUOutletBankIndex | read-only | mandatory | The index to the Switched Rack PDU bank entry. |
| 1.3.6.1.4.1.318.1.1.12.3.6.1.1.2 | ColumnrPDUOutletBankOverloadRestriction | read-write | mandatory | This OID controls the behavior of a Switched Rack PDU bank when an overload condition is possible and additional outlets are requested to be turned on. Setting… |
| 1.3.6.1.4.1.318.1.1.12.4 | NoderPDUPowerSupply | |||
| 1.3.6.1.4.1.318.1.1.12.4.1 | NoderPDUPowerSupplyDevice | |||
| 1.3.6.1.4.1.318.1.1.12.4.1.1 | ScalarrPDUPowerSupply1Status | read-only | mandatory | Getting this OID will return powerSupply1Ok(1) if power supply 1 is functioning normally. If not functioning normally, this OID will return powerSupply1Failed(… |
| 1.3.6.1.4.1.318.1.1.12.4.1.2 | ScalarrPDUPowerSupply2Status | read-only | mandatory | Getting this OID will return powerSupply2Ok(1) if power supply 2 is functioning normally. If not functioning normally, this OID will return powerSupply2Failed(… |
| 1.3.6.1.4.1.318.1.1.12.4.1.3 | ScalarrPDUPowerSupplyAlarm | read-only | mandatory | Getting this OID will return powerSupply Alarm |
| 1.3.6.1.4.1.318.1.1.12.5 | NoderPDUStatus | |||
| 1.3.6.1.4.1.318.1.1.12.5.1 | ScalarrPDUStatusBankTableSize | read-only | mandatory | The size of the Status Bank Table |
| 1.3.6.1.4.1.318.1.1.12.5.2 | TablerPDUStatusBankTable | not-accessible | mandatory | Allows for getting of status of each Rack PDU Bank |
| 1.3.6.1.4.1.318.1.1.12.5.2.1 | RowrPDUStatusBankEntry | not-accessible | mandatory | This gives access to Bank entries |
| 1.3.6.1.4.1.318.1.1.12.5.2.1.1 | ColumnrPDUStatusBankIndex | read-only | mandatory | The index to the RACK PDU Bank entry. |
| 1.3.6.1.4.1.318.1.1.12.5.2.1.2 | ColumnrPDUStatusBankNumber | read-only | mandatory | Getting this OID will return the bank number. |
| 1.3.6.1.4.1.318.1.1.12.5.2.1.3 | ColumnrPDUStatusBankState | read-only | mandatory | Getting this OID will return the bank load state. bankLoadNormal(1) indicates that the bank is operating properly within the rPDULoadBankConfigLowLoadThreshold… |
| 1.3.6.1.4.1.318.1.1.12.5.3 | ScalarrPDUStatusPhaseTableSize | read-only | mandatory | The size of the Status Phase Table |
| 1.3.6.1.4.1.318.1.1.12.5.4 | TablerPDUStatusPhaseTable | not-accessible | mandatory | Allows for getting of status of each Rack PDU Phase |
| 1.3.6.1.4.1.318.1.1.12.5.4.1 | RowrPDUStatusPhaseEntry | not-accessible | mandatory | This gives access to Phase entries |
| 1.3.6.1.4.1.318.1.1.12.5.4.1.1 | ColumnrPDUStatusPhaseIndex | read-only | mandatory | The index to the RACK PDU Phase entry. |
| 1.3.6.1.4.1.318.1.1.12.5.4.1.2 | ColumnrPDUStatusPhaseNumber | read-only | mandatory | Getting this OID will return the phase number. |
| 1.3.6.1.4.1.318.1.1.12.5.4.1.3 | ColumnrPDUStatusPhaseState | read-only | mandatory | Getting this OID will return the Phase load state. phaseLoadNormal(1) indicates that the Phase is operating properly within the rPDULoadPhaseConfigLowLoadThres… |
| 1.3.6.1.4.1.318.1.1.12.5.5 | ScalarrPDUStatusOutletTableSize | read-only | mandatory | The size of the Status Outlet Table |
| 1.3.6.1.4.1.318.1.1.12.5.6 | TablerPDUStatusOutletTable | not-accessible | mandatory | Allows for getting of status of each Outlet of an Outlet Monitored Rack PDU. |
| 1.3.6.1.4.1.318.1.1.12.5.6.1 | RowrPDUStatusOutletEntry | not-accessible | mandatory | This gives access to Outlet entries |
| 1.3.6.1.4.1.318.1.1.12.5.6.1.1 | ColumnrPDUStatusOutletIndex | read-only | mandatory | The index to the RACK PDU Outlet entry. |
| 1.3.6.1.4.1.318.1.1.12.5.6.1.2 | ColumnrPDUStatusOutletNumber | read-only | mandatory | Getting this OID will return the Outlet number. |
| 1.3.6.1.4.1.318.1.1.12.5.6.1.3 | ColumnrPDUStatusOutletState | read-only | mandatory | Getting this OID will return the Outlet load state. outletLoadNormal(1) indicates that the Outlet is operating properly within the rPDUOutletConfigMonitoredLow… |
| 1.3.6.1.4.1.318.1.1.13 | NodeairConditioners | |||
| 1.3.6.1.4.1.318.1.1.13.1 | NodeairFM | |||
| 1.3.6.1.4.1.318.1.1.13.1.1 | NodeairFMIdent | |||
| 1.3.6.1.4.1.318.1.1.13.1.1.1 | ScalarairFMIdentName | read-write | mandatory | A character string identifying the device. |
| 1.3.6.1.4.1.318.1.1.13.1.1.2 | ScalarairFMIdentTableSize | read-only | mandatory | The number of entries in the airFMIdentTable. |
| 1.3.6.1.4.1.318.1.1.13.1.1.3 | TableairFMIdentTable | not-accessible | mandatory | Allows for getting identification information from each module in the system. |
| 1.3.6.1.4.1.318.1.1.13.1.1.3.1 | RowairFMIdentEntry | not-accessible | mandatory | The module to get information from. |
| 1.3.6.1.4.1.318.1.1.13.1.1.3.1.1 | ColumnairFMIdentModuleIndex | read-only | mandatory | The index of the module information. |
| 1.3.6.1.4.1.318.1.1.13.1.1.3.1.2 | ColumnairFMIdentModuleModelNumber | read-only | mandatory | A character string identifying the model number. |
| 1.3.6.1.4.1.318.1.1.13.1.1.3.1.3 | ColumnairFMIdentModuleDateOfMfg | read-only | mandatory | A character string identifying the manufacture date. |
| 1.3.6.1.4.1.318.1.1.13.1.1.3.1.4 | ColumnairFMIdentModuleSerialNumber | read-only | mandatory | A character string identifying the unit serial number. |
| 1.3.6.1.4.1.318.1.1.13.1.1.3.1.5 | ColumnairFMIdentModuleFirmwareRev | read-only | mandatory | A character string identifying the firmware revision. |
| 1.3.6.1.4.1.318.1.1.13.1.1.3.1.6 | ColumnairFMIdentModuleHardwareRev | read-only | mandatory | A character string identifying the hardware revision. |
| 1.3.6.1.4.1.318.1.1.13.1.1.4 | ScalarairFMIdentLocation | read-write | mandatory | A character string identifying the location of the device. |
| 1.3.6.1.4.1.318.1.1.13.1.1.5 | ScalarairFMIdentContact | read-write | mandatory | A character string identifying the person to contact regarding the device. |
| 1.3.6.1.4.1.318.1.1.13.1.2 | NodeairFMStatus | |||
| 1.3.6.1.4.1.318.1.1.13.1.2.1 | ScalarairFMStatusSystemOn | read-only | mandatory | The operating state of the system. This OID has been deprecated in favor of airFMGroupSysStatus. |
| 1.3.6.1.4.1.318.1.1.13.1.2.2 | ScalarairFMStatusSystemAverageRetTempC | read-only | mandatory | The system average return air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMSysAvgReturnTempC. |
| 1.3.6.1.4.1.318.1.1.13.1.2.3 | ScalarairFMStatusSystemAverageRetTempF | read-only | mandatory | The system average return air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMSysAvgReturnTempF. |
| 1.3.6.1.4.1.318.1.1.13.1.2.4 | ScalarairFMStatusSystemAverageRetHum | read-only | mandatory | The system average return air humidity in tenths of percent RH. This OID has been deprecated in favor of airFMSysAvgReturnHum. |
| 1.3.6.1.4.1.318.1.1.13.1.2.5 | ScalarairFMStatusSystemActionTempC | read-only | mandatory | The system action air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMSysCtrlTempC. |
| 1.3.6.1.4.1.318.1.1.13.1.2.6 | ScalarairFMStatusSystemActionTempF | read-only | mandatory | The system action air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMSysCtrlTempF. |
| 1.3.6.1.4.1.318.1.1.13.1.2.7 | ScalarairFMStatusSystemActionHum | read-only | mandatory | The system action air humidity in tenths of percent RH. This OID has been deprecated in favor of airFMSysCtrlHum. |
| 1.3.6.1.4.1.318.1.1.13.1.2.8 | ScalarairFMStatusSystemRemoteHighTempC | read-only | mandatory | The system remote high air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMSysMaxRemoteTempC. |
| 1.3.6.1.4.1.318.1.1.13.1.2.9 | ScalarairFMStatusSystemRemoteHighTempF | read-only | mandatory | The system remote high air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMSysMaxRemoteTempF. |
| 1.3.6.1.4.1.318.1.1.13.1.2.10 | ScalarairFMStatusSystemRemoteAvgTempC | read-only | mandatory | The system remote average air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMSysAvgRemoteTempC. |
| 1.3.6.1.4.1.318.1.1.13.1.2.11 | ScalarairFMStatusSystemRemoteAvgTempF | read-only | mandatory | The system remote average air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMSysAvgRemoteTempF. |
| 1.3.6.1.4.1.318.1.1.13.1.2.12 | ScalarairFMStatusSystemRemoteAvgHum | read-only | mandatory | The system remote average air humidity in tenths of percent RH. This OID has been deprecated in favor of airFMSysAvgRemoteHum. |
| 1.3.6.1.4.1.318.1.1.13.1.2.13 | ScalarairFMStatusSystemRemoteLowTempC | read-only | mandatory | The system remote low air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMSysMinRemoteTempC. |
| 1.3.6.1.4.1.318.1.1.13.1.2.14 | ScalarairFMStatusSystemRemoteLowTempF | read-only | mandatory | The system remote low air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMSysMinRemoteTempF. |
| 1.3.6.1.4.1.318.1.1.13.1.2.15 | ScalarairFMStatusSystemCoolingEnabled | read-only | mandatory | The state of the system cooling function enable. This OID has been deprecated in favor of airFMSysCoolState. |
| 1.3.6.1.4.1.318.1.1.13.1.2.16 | ScalarairFMStatusSystemReheatingEnabled | read-only | mandatory | The state of the system reheating function enable. This OID has been deprecated in favor of airFMSysReheatState. |
| 1.3.6.1.4.1.318.1.1.13.1.2.17 | ScalarairFMStatusSystemHumidifyEnabled | read-only | mandatory | The state of the system humidify function enable. This OID has been deprecated in favor of airFMSysHumState. |
| 1.3.6.1.4.1.318.1.1.13.1.2.18 | ScalarairFMStatusSystemDehumidifyEnabled | read-only | mandatory | The state of the system dehumidify function enable. This OID has been deprecated in favor of airFMSysDehumState. |
| 1.3.6.1.4.1.318.1.1.13.1.2.19 | ScalarairFMStatusModuleTableSize | read-only | mandatory | The number of entries in the airFMStatusModuleTable. |
| 1.3.6.1.4.1.318.1.1.13.1.2.20 | TableairFMStatusModuleTable | not-accessible | mandatory | Allows for getting information from each module in the system. |
| 1.3.6.1.4.1.318.1.1.13.1.2.20.1 | RowairFMStatusModuleEntry | not-accessible | mandatory | The module to get status from. |
| 1.3.6.1.4.1.318.1.1.13.1.2.20.1.1 | ColumnairFMStatusModuleIndex | read-only | mandatory | The index of the module information. |
| 1.3.6.1.4.1.318.1.1.13.1.2.20.1.2 | ColumnairFMStatusModuleOutputCapacity | read-only | mandatory | The module output capacity in kilowatts. This OID has been deprecated in favor of airFMModOutputCapacity. |
| 1.3.6.1.4.1.318.1.1.13.1.2.20.1.3 | ColumnairFMStatusModuleSupplyTempC | read-only | mandatory | The module supply air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMModSupplyTempC. |
| 1.3.6.1.4.1.318.1.1.13.1.2.20.1.4 | ColumnairFMStatusModuleSupplyTempF | read-only | mandatory | The module supply air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMModSupplyTempF. |
| 1.3.6.1.4.1.318.1.1.13.1.2.20.1.5 | ColumnairFMStatusModuleSupplyHum | read-only | mandatory | The module supply air humidity in tenths of percent RH. This OID has been deprecated in favor of airFMModSupplyHum. |
| 1.3.6.1.4.1.318.1.1.13.1.2.20.1.6 | ColumnairFMStatusModuleReturnTempC | read-only | mandatory | The module return air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMModReturnTempC. |
| 1.3.6.1.4.1.318.1.1.13.1.2.20.1.7 | ColumnairFMStatusModuleReturnTempF | read-only | mandatory | The module return air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMModReturnTempF. |
| 1.3.6.1.4.1.318.1.1.13.1.2.20.1.8 | ColumnairFMStatusModuleReturnHum | read-only | mandatory | The module return air humidity in tenths of percent RH. This OID has been deprecated in favor of airFMModReturnHum. |
| 1.3.6.1.4.1.318.1.1.13.1.3 | NodeairFMGroup | |||
| 1.3.6.1.4.1.318.1.1.13.1.3.1 | ScalarairFMGroupSysStatus | read-only | mandatory | The status of this system within the group. |
| 1.3.6.1.4.1.318.1.1.13.1.3.2 | ScalarairFMGroupSysRuntime | read-only | mandatory | The number of hours the system has been running. |
| 1.3.6.1.4.1.318.1.1.13.1.3.3 | ScalarairFMGroupSysRole | read-only | mandatory | The role of this system within the group. |
| 1.3.6.1.4.1.318.1.1.13.1.3.4 | NodeairFMGroupSysRoles | |||
| 1.3.6.1.4.1.318.1.1.13.1.3.4.1 | ScalarairFMGroupSysRolesTableSize | read-only | mandatory | The number of entries in the airFMGroupSysRolesTable. |
| 1.3.6.1.4.1.318.1.1.13.1.3.4.2 | TableairFMGroupSysRolesTable | not-accessible | mandatory | Allows for getting information from each system in the group. |
| 1.3.6.1.4.1.318.1.1.13.1.3.4.2.1 | RowairFMGroupSysRolesEntry | not-accessible | mandatory | The system to get status from. |
| 1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.1 | ColumnairFMGroupSysIndex | read-only | mandatory | The index of the system information. |
| 1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.2 | ColumnairFMGroupSysRoleStatus | read-only | mandatory | The present mode of the System. |
| 1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.3 | ColumnairFMGroupSysPresentRole | read-only | mandatory | The present role of the System in a Group. |
| 1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.4 | ColumnairFMGroupSysManualRoleSetting | read-write | mandatory | The manual role setting of the System in a Group. Only applies if Role Assignment Method is set to static (Manually Assigned Roles). |
| 1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.5 | ColumnairFMGroupSysRunHours | read-only | mandatory | The total number of hours the System has been contributing to environmental control. |
| 1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.6 | ColumnairFMGroupSysComm | read-only | mandatory | Indicates whether a system is communicating with the other Systems in the Group. |
| 1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.7 | ColumnairFMGroupSysIPAddress | read-only | mandatory | The IP Address of the System. |
| 1.3.6.1.4.1.318.1.1.13.1.3.4.3 | ScalarairFMGroupSysRoleAssignment | read-write | mandatory | The method used to assign roles (i.e. Primary, Backup) to the Systems in a Group. staticManual: Manually assign Primary or Backup to regulate run hours across … |
| 1.3.6.1.4.1.318.1.1.13.1.3.4.4 | ScalarairFMGroupAutoRoleNumPrimary | read-write | mandatory | The number of Systems assigned the 'primary' role in this Group. Only applies if Role Assignment Method is set to dynamic (Automatic Run Hour Balancing). |
| 1.3.6.1.4.1.318.1.1.13.1.3.5 | NodeairFMGroupCfg | |||
| 1.3.6.1.4.1.318.1.1.13.1.3.5.1 | ScalarairFMGroupCfgName | read-write | mandatory | A character string identifying the group name. |
| 1.3.6.1.4.1.318.1.1.13.1.3.5.2 | ScalarairFMGroupCfgNumSystems | read-write | mandatory | The number of Systems in this Group. |
| 1.3.6.1.4.1.318.1.1.13.1.3.5.3 | ScalarairFMGroupCfgIdleBlower | read-write | mandatory | Blower behavior for backup Systems and Systems that have entered a failure mode. |
| 1.3.6.1.4.1.318.1.1.13.1.3.5.4 | ScalarairFMGroupCfgShutdownSmoke | read-write | mandatory | If enabled, all Systems in the Group will shut down if smoke is detected. |
| 1.3.6.1.4.1.318.1.1.13.1.3.5.5 | ScalarairFMGroupCfgShutdownFire | read-write | mandatory | If enabled, all Systems in the Group will shut down if fire is detected. |
| 1.3.6.1.4.1.318.1.1.13.1.3.5.6 | ScalarairFMGroupCfgFailoverCommLoss | read-write | mandatory | Failover on Comm Loss enables an available backup System to run in place of a System that has lost communication with the Group. |
| 1.3.6.1.4.1.318.1.1.13.1.3.5.7 | ScalarairFMGroupCfgDmdFightStatus | read-only | mandatory | Demand Fighting and Setpoint Sharing are automatically enabled when a System is responding to a Load Sharing Request. |
| 1.3.6.1.4.1.318.1.1.13.1.3.5.8 | ScalarairFMGroupCfgDmdFightSetting | read-write | mandatory | Demand Fighting prevents a System from engaging reheat in a Group where any System is cooling. |
| 1.3.6.1.4.1.318.1.1.13.1.3.5.9 | ScalarairFMGroupCfgSetpointShareStatus | read-only | mandatory | Demand Fighting and Setpoint Sharing are automatically enabled when a System is responding to Load Sharing Request. |
| 1.3.6.1.4.1.318.1.1.13.1.3.5.10 | ScalarairFMGroupCfgSetpointShareSetting | read-write | mandatory | All Systems in the Group use the same setpoints. |
| 1.3.6.1.4.1.318.1.1.13.1.3.5.11 | ScalarairFMGroupCfgResetFieldServiceDefaults | read-write | mandatory | Setting this OID to reset(2) will reset all Group parameters, which can only be edited by a field service engineer, to their factory default values. Getting th… |
| 1.3.6.1.4.1.318.1.1.13.1.3.6 | NodeairFMGroupLoadShare | |||
| 1.3.6.1.4.1.318.1.1.13.1.3.6.1 | ScalarairFMGroupLoadShareCoolRequests | read-write | mandatory | Systems that are cooling may request assistance from other Systems in the Group. |
| 1.3.6.1.4.1.318.1.1.13.1.3.6.2 | ScalarairFMGroupLoadShareCoolThreshC | read-write | mandatory | Temperature threshold at which a System will generate a load sharing request for cooling. Measured in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.1.3.6.3 | ScalarairFMGroupLoadShareCoolThreshF | read-write | mandatory | Temperature threshold at which a System will generate a load sharing request for cooling. Measured in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.1.3.6.4 | ScalarairFMGroupLoadShareReheatRequests | read-write | mandatory | Systems that are reheating may request assistance from other Systems in the Group. |
| 1.3.6.1.4.1.318.1.1.13.1.3.6.5 | ScalarairFMGroupLoadShareReheatThreshC | read-write | mandatory | Temperature threshold at which a System will generate a load sharing request for reheating. Measured in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.1.3.6.6 | ScalarairFMGroupLoadShareReheatThreshF | read-write | mandatory | Temperature threshold at which a System will generate a load sharing request for reheating. Measured in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.1.3.6.7 | ScalarairFMGroupLoadShareHumRequests | read-write | mandatory | Systems that are humidifying may request humidification assistance from other Systems in the Group. |
| 1.3.6.1.4.1.318.1.1.13.1.3.6.8 | ScalarairFMGroupLoadShareHumThresh | read-write | mandatory | Humidity threshold at which a System will generate a load sharing request for humidification. Measured in tenths of percent relative humidity. |
| 1.3.6.1.4.1.318.1.1.13.1.3.6.9 | ScalarairFMGroupLoadShareDehumRequests | read-write | mandatory | Systems that are dehumidifying may request assistance from other Systems in the Group. |
| 1.3.6.1.4.1.318.1.1.13.1.3.6.10 | ScalarairFMGroupLoadShareDehumThresh | read-write | mandatory | Humidity threshold at which a System will generate a load sharing request for dehumidification. Measured in tenths of percent relative humidity. |
| 1.3.6.1.4.1.318.1.1.13.1.3.7 | NodeairFMGroupFailover | |||
| 1.3.6.1.4.1.318.1.1.13.1.3.7.1 | NodeairFMGroupFailoverSys | |||
| 1.3.6.1.4.1.318.1.1.13.1.3.7.1.1 | ScalarairFMGroupFailoverSysAnyMinorAlarm | read-write | mandatory | Enabling this OID will cause the system to enter a failure state if any minor system alarm is active. Once in the failure state, environmental control ceases f… |
| 1.3.6.1.4.1.318.1.1.13.1.3.7.1.2 | ScalarairFMGroupFailoverSysAnyMajorAlarm | read-write | mandatory | Enabling this OID will cause the system to enter a failure state if any major system alarm is active. Once in the failure state, environmental control ceases f… |
| 1.3.6.1.4.1.318.1.1.13.1.3.7.1.3 | ScalarairFMGroupFailoverSysHighEnvTemp | read-write | mandatory | Enabling this OID will cause the system to enter a failure state if the high environmental temperature alarm is active. Once in the failure state, environmenta… |
| 1.3.6.1.4.1.318.1.1.13.1.3.7.1.4 | ScalarairFMGroupFailoverSysLowEnvTemp | read-write | mandatory | Enabling this OID will cause the system to enter a failure state if the low environmental temperature alarm is active. Once in the failure state, environmental… |
| 1.3.6.1.4.1.318.1.1.13.1.3.7.1.5 | ScalarairFMGroupFailoverSysHighEnvHum | read-write | mandatory | Enabling this OID will cause the system to enter a failure state if the high environmental humidity alarm is active. Once in the failure state, environmental c… |
| 1.3.6.1.4.1.318.1.1.13.1.3.7.1.6 | ScalarairFMGroupFailoverSysLowEnvHum | read-write | mandatory | Enabling this OID will cause the system to enter a failure state if the low environmental humidity alarm is active. Once in the failure state, environmental co… |
| 1.3.6.1.4.1.318.1.1.13.1.3.7.1.7 | ScalarairFMGroupFailoverSysFireAlarm | read-write | mandatory | Enabling this OID will cause the system to enter a failure state if the fire alarm is active. Once in the failure state, environmental control ceases for the s… |
| 1.3.6.1.4.1.318.1.1.13.1.3.7.1.8 | ScalarairFMGroupFailoverSysSmokeAlarm | read-write | mandatory | Enabling this OID will cause the system to enter a failure state if the smoke alarm is active. Once in the failure state, environmental control ceases for the … |
| 1.3.6.1.4.1.318.1.1.13.1.3.7.1.9 | ScalarairFMGroupFailoverSysCommLost | read-write | mandatory | Enabling this OID will cause the system to enter a failure state if the system has lost comm. Once in the failure state, environmental control ceases for the s… |
| 1.3.6.1.4.1.318.1.1.13.1.3.7.1.10 | ScalarairFMGroupFailoverSysSupplySensorFail | read-write | mandatory | Enabling this OID will cause the system to enter a failure state if the supply sensor has failed. Once in the failure state, environmental control ceases for t… |
| 1.3.6.1.4.1.318.1.1.13.1.3.7.1.11 | ScalarairFMGroupFailoverSysReturnSensorFail | read-write | mandatory | Enabling this OID will cause the system to enter a failure state if the return sensor has failed. Once in the failure state, environmental control ceases for t… |
| 1.3.6.1.4.1.318.1.1.13.1.3.7.1.12 | ScalarairFMGroupFailoverSysPrimarySensorFail | read-write | mandatory | Enabling this OID will cause the system to enter a failure state if the primary sensor has failed. Once in the failure state, environmental control ceases for … |
| 1.3.6.1.4.1.318.1.1.13.1.3.7.1.13 | ScalarairFMGroupFailoverSysSecondarySensorFail | read-write | mandatory | Enabling this OID will cause the system to enter a failure state if the secondary sensor has failed. Once in the failure state, environmental control ceases fo… |
| 1.3.6.1.4.1.318.1.1.13.1.3.7.1.14 | ScalarairFMGroupFailoverSysNoSensorsAvailable | read-write | mandatory | Enabling this OID will cause the system to enter a failure state if no sensors are available. Once in the failure state, environmental control ceases for the s… |
| 1.3.6.1.4.1.318.1.1.13.1.3.7.2 | NodeairFMGroupFailoverMod | |||
| 1.3.6.1.4.1.318.1.1.13.1.3.7.2.1 | ScalarairFMGroupFailoverModMaintRequired | read-write | mandatory | Enabling this OID will cause the system to enter a failure state if maintenance is required on a module. Once in the failure state, environmental control cease… |
| 1.3.6.1.4.1.318.1.1.13.1.3.7.2.2 | ScalarairFMGroupFailoverModCoolFail | read-write | mandatory | Enabling this OID will cause the system to enter a failure state if cooling has failed on a module. Once in the failure state, environmental control ceases for… |
| 1.3.6.1.4.1.318.1.1.13.1.3.7.2.3 | ScalarairFMGroupFailoverModHumFail | read-write | mandatory | Enabling this OID will cause the system to enter a failure state if the humidifier has failed on a module. Once in the failure state, environmental control cea… |
| 1.3.6.1.4.1.318.1.1.13.1.3.7.2.4 | ScalarairFMGroupFailoverModBlwrCntrl1Fail | read-write | mandatory | Enabling this OID will cause the system to enter a failure state if blower controller 1 has failed on a module. Once in the failure state, environmental contro… |
| 1.3.6.1.4.1.318.1.1.13.1.3.7.2.5 | ScalarairFMGroupFailoverModBlwrCntrl2Fail | read-write | mandatory | Enabling this OID will cause the system to enter a failure state if blower controller 2 has failed on a module. Once in the failure state, environmental contro… |
| 1.3.6.1.4.1.318.1.1.13.1.3.7.2.6 | ScalarairFMGroupFailoverModHighFilterDP | read-write | mandatory | Enabling this OID will cause the system to enter a failure state if a high filter differential pressure is present on a module. Once in the failure state, envi… |
| 1.3.6.1.4.1.318.1.1.13.1.3.7.2.7 | ScalarairFMGroupFailoverModHighSupplyTemp | read-write | mandatory | Enabling this OID will cause the system to enter a failure state if a high supply temperature is active on a module. Once in the failure state, environmental c… |
| 1.3.6.1.4.1.318.1.1.13.1.3.7.2.8 | ScalarairFMGroupFailoverModLowSupplyTemp | read-write | mandatory | Enabling this OID will cause the system to enter a failure state if a low supply temperature is active on a module. Once in the failure state, environmental co… |
| 1.3.6.1.4.1.318.1.1.13.1.3.7.2.9 | ScalarairFMGroupFailoverModLossOrLowAirFlow | read-write | mandatory | Enabling this OID will cause the system to enter a failure state if there is a loss of air flow or low air flow on a module. Once in the failure state, environ… |
| 1.3.6.1.4.1.318.1.1.13.1.3.7.2.10 | ScalarairFMGroupFailoverModHumReplaceCylinder | read-write | mandatory | Enabling this OID will cause the system to enter a failure state if a humidifier needs its cylinder replaced on a module. Once in the failure state, environmen… |
| 1.3.6.1.4.1.318.1.1.13.1.3.7.2.11 | ScalarairFMGroupFailoverModAirBlockInterlockOpen | read-write | mandatory | Enabling this OID will cause the system to enter a failure state if the air block interlock is open on a module. Once in the failure state, environmental contr… |
| 1.3.6.1.4.1.318.1.1.13.1.3.7.2.12 | ScalarairFMGroupFailoverModWaterDetected | read-write | mandatory | Enabling this OID will cause the system to enter a failure state if water is detected by a module. Once in the failure state, environmental control ceases for … |
| 1.3.6.1.4.1.318.1.1.13.1.3.7.2.13 | ScalarairFMGroupFailoverModCondensatePumpFail | read-write | mandatory | Enabling this OID will cause the system to enter a failure state if the condensate pump has failed in a module. Once in the failure state, environmental contro… |
| 1.3.6.1.4.1.318.1.1.13.1.4 | NodeairFMSystem | |||
| 1.3.6.1.4.1.318.1.1.13.1.4.1 | NodeairFMSysStatus | |||
| 1.3.6.1.4.1.318.1.1.13.1.4.1.1 | ScalarairFMSysNumber | read-only | mandatory | The number of the system within the group. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.1.2 | ScalarairFMSysPresentStatus | read-only | mandatory | The present mode of the System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.1.3 | ScalarairFMSysPresentRole | read-only | mandatory | The present role of the System in the Group. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.1.4 | ScalarairFMSysRunHours | read-only | mandatory | The total number of hours the System has been contributing to environmental control. A value of -2147483648 indicates that this OID does not apply to this devi… |
| 1.3.6.1.4.1.318.1.1.13.1.4.1.5 | ScalarairFMSysCoilFluidTempC | read-only | mandatory | The temperature of the coolant at the fluid coil inlet. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this devi… |
| 1.3.6.1.4.1.318.1.1.13.1.4.1.6 | ScalarairFMSysCoilFluidTempF | read-only | mandatory | The temperature of the coolant at the fluid coil inlet. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this d… |
| 1.3.6.1.4.1.318.1.1.13.1.4.1.7 | ScalarairFMSysHotWaterTempC | read-only | mandatory | The hot water temperature. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.1.8 | ScalarairFMSysHotWaterTempF | read-only | mandatory | The hot water temperature. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuratio… |
| 1.3.6.1.4.1.318.1.1.13.1.4.1.9 | ScalarairFMSysAvgReturnTempC | read-only | mandatory | The average return temperature calculated from all present modules. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does … |
| 1.3.6.1.4.1.318.1.1.13.1.4.1.10 | ScalarairFMSysAvgReturnTempF | read-only | mandatory | The average return temperature calculated from all present modules. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID do… |
| 1.3.6.1.4.1.318.1.1.13.1.4.1.11 | ScalarairFMSysAvgReturnHum | read-only | mandatory | The average return humidity calculated from all present modules. Measured in tenths of percent RH. A value of -2147483648 indicates that this OID does not appl… |
| 1.3.6.1.4.1.318.1.1.13.1.4.1.12 | ScalarairFMSysAvgRemoteTempC | read-only | mandatory | The average temperature calculated from all operational remote sensors. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID d… |
| 1.3.6.1.4.1.318.1.1.13.1.4.1.13 | ScalarairFMSysAvgRemoteTempF | read-only | mandatory | The average temperature calculated from all operational remote sensors. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OI… |
| 1.3.6.1.4.1.318.1.1.13.1.4.1.14 | ScalarairFMSysAvgRemoteHum | read-only | mandatory | The average return humidity calculated from all present modules. Measured in tenths of percent RH. A value of -2147483648 indicates that this OID does not appl… |
| 1.3.6.1.4.1.318.1.1.13.1.4.1.15 | ScalarairFMSysMaxRemoteTempC | read-only | mandatory | The maximum temperature reading from all operational remote sensors. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does… |
| 1.3.6.1.4.1.318.1.1.13.1.4.1.16 | ScalarairFMSysMaxRemoteTempF | read-only | mandatory | The maximum temperature reading from all operational remote sensors. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID d… |
| 1.3.6.1.4.1.318.1.1.13.1.4.1.17 | ScalarairFMSysMinRemoteTempC | read-only | mandatory | The minimum temperature reading from all operational remote sensors. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does… |
| 1.3.6.1.4.1.318.1.1.13.1.4.1.18 | ScalarairFMSysMinRemoteTempF | read-only | mandatory | The minimum temperature reading from all operational remote sensors. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID d… |
| 1.3.6.1.4.1.318.1.1.13.1.4.1.19 | ScalarairFMSysTempCtrlMethod | read-only | mandatory | The method of environment temperature control selected to regulate the temperature. A value of notApplicable indicates that this OID does not apply to this dev… |
| 1.3.6.1.4.1.318.1.1.13.1.4.1.20 | ScalarairFMSysActualTempCtrlMethod | read-only | mandatory | The actual method of environment temperature control being used to regulate the temperature. A value of notApplicable indicates that this OID does not apply to… |
| 1.3.6.1.4.1.318.1.1.13.1.4.1.21 | ScalarairFMSysHumCtrlMethod | read-only | mandatory | The method of environment humidity control selected to regulate the humidity. A value of notApplicable indicates that this OID does not apply to this device du… |
| 1.3.6.1.4.1.318.1.1.13.1.4.1.22 | ScalarairFMSysActualHumCtrlMethod | read-only | mandatory | The actual method of environment humidity control being used to regulate the humidity. A value of notApplicable indicates that this OID does not apply to this … |
| 1.3.6.1.4.1.318.1.1.13.1.4.1.23 | ScalarairFMSysCtrlTempC | read-only | mandatory | The system environmental control air temperature from the sensor denoted by airFMSysActualTempCtrl. Measured in tenths of degrees Celsius. A value of -21474836… |
| 1.3.6.1.4.1.318.1.1.13.1.4.1.24 | ScalarairFMSysCtrlTempF | read-only | mandatory | The system environmental control air temperature from the sensor denoted by airFMSysActualTempCtrl. Measured in tenths of degrees Fahrenheit. A value of -21474… |
| 1.3.6.1.4.1.318.1.1.13.1.4.1.25 | ScalarairFMSysCtrlHum | read-only | mandatory | The system environmental control air humidity from the sensor denoted by airFMSysActualHumCtrl. Measured in percent relative humidity. A value of -2147483648 i… |
| 1.3.6.1.4.1.318.1.1.13.1.4.2 | NodeairFMSysDemands | |||
| 1.3.6.1.4.1.318.1.1.13.1.4.2.1 | ScalarairFMSysDXCoolingDmd | read-only | mandatory | The direct expansion cooling output demanded by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device d… |
| 1.3.6.1.4.1.318.1.1.13.1.4.2.2 | ScalarairFMSysDXDehumDmd | read-only | mandatory | The direct expansion dehumidification output demanded by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this… |
| 1.3.6.1.4.1.318.1.1.13.1.4.2.3 | ScalarairFMSysDXActualCoolDehum | read-only | mandatory | The direct expansion cooling or dehumidification output measured by the System. Measured in percent. A value of -2147483648 indicates that this OID does not ap… |
| 1.3.6.1.4.1.318.1.1.13.1.4.2.4 | ScalarairFMSysCoilFluidCoolDmd | read-only | mandatory | The fluid coil cooling output demanded by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to … |
| 1.3.6.1.4.1.318.1.1.13.1.4.2.5 | ScalarairFMSysCoilFluidDehumDmd | read-only | mandatory | The fluid coil dehumidification output demanded by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this devic… |
| 1.3.6.1.4.1.318.1.1.13.1.4.2.6 | ScalarairFMSysCoilFluidActualCoolDehum | read-only | mandatory | The fluid coil cooling or dehumidification output measured by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to… |
| 1.3.6.1.4.1.318.1.1.13.1.4.2.7 | ScalarairFMSysElectricReheatDmd | read-only | mandatory | The electric reheating output demanded by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to … |
| 1.3.6.1.4.1.318.1.1.13.1.4.2.8 | ScalarairFMSysActualElectricReheat | read-only | mandatory | The electric reheating output of the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its confi… |
| 1.3.6.1.4.1.318.1.1.13.1.4.2.9 | ScalarairFMSysSteamHotGasReheatDmd | read-only | mandatory | The steam, hot water, or hot gas reheating output demanded by the System. A value of notApplicable indicates that this OID does not apply to this device due to… |
| 1.3.6.1.4.1.318.1.1.13.1.4.2.10 | ScalarairFMSysActualSteamHotGasReheat | read-only | mandatory | The steam, hot water, or hot gas reheating output of the System. A value of notApplicable indicates that this OID does not apply to this device due to its conf… |
| 1.3.6.1.4.1.318.1.1.13.1.4.2.11 | ScalarairFMSysSteamElectrodeHumDmd | read-only | mandatory | The steam electrode humidification output demanded by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this de… |
| 1.3.6.1.4.1.318.1.1.13.1.4.2.12 | ScalarairFMSysActualSteamElectrodeHum | read-only | mandatory | The average steam electrode humidification output measured for the Modules in the System. Measured in percent. A value of -2147483648 indicates that this OID d… |
| 1.3.6.1.4.1.318.1.1.13.1.4.2.13 | ScalarairFMSysSteamHumDmd | read-only | mandatory | The steam humidification output demanded by the System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.2.14 | ScalarairFMSysActualSteamHum | read-only | mandatory | The steam humidification output for the System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.3 | NodeairFMSysSetup | |||
| 1.3.6.1.4.1.318.1.1.13.1.4.3.1 | ScalarairFMSysNumModules | read-only | mandatory | The number of Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.3.2 | ScalarairFMSysNumPCIOMs | read-only | mandatory | The number of Programmable Customer Input/Output Modules (PCIOMs) installed in the Main Module of this System. Each PCIOM adds four input contacts and four out… |
| 1.3.6.1.4.1.318.1.1.13.1.4.3.3 | ScalarairFMSysMainsVlt | read-only | mandatory | The mains voltage for the Modules in this System. A value of N/A indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.3.4 | ScalarairFMSysUPSVlt | read-only | mandatory | The UPS voltage for the Modules in this System. A value of N/A indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.3.5 | ScalarairFMSysCoilCfg | read-only | mandatory | The type of cooling coils installed in the Modules in this System: DX coil, DX and MultiCool (chilled water) coils, DX and Economizer coils, or only a Chilled … |
| 1.3.6.1.4.1.318.1.1.13.1.4.3.6 | ScalarairFMSysRefrigType | read-only | mandatory | The type of refrigerant used by each compressor in the system. A value of notApplicable indicates that this OID does not apply to this device due to its config… |
| 1.3.6.1.4.1.318.1.1.13.1.4.3.7 | ScalarairFMSysHeatRejection | read-only | mandatory | The method the Modules in this System use to transfer heat away from the refrigerant. A value of notApplicable indicates that this OID does not apply to this d… |
| 1.3.6.1.4.1.318.1.1.13.1.4.3.8 | ScalarairFMSysDischAirPtrn | read-only | mandatory | The discharge air pattern for the Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to its configurati… |
| 1.3.6.1.4.1.318.1.1.13.1.4.3.9 | ScalarairFMSysAirFltr | read-only | mandatory | The type of air filters (standard or high efficiency) installed in the Modules of this System. A value of notApplicable indicates that this OID does not apply … |
| 1.3.6.1.4.1.318.1.1.13.1.4.3.10 | ScalarairFMSysFlowSwitch | read-only | mandatory | The location of the optional flow switch. None: No flow switch is installed in this System. DX: Coolant input to the heat exchanger (condenser). MultiCool: Chi… |
| 1.3.6.1.4.1.318.1.1.13.1.4.3.11 | ScalarairFMSysCoilFluidVlvAct | read-only | mandatory | The type of valve actuator installed on the coil fluid valve. The coil fluid valve controls the flow of coolant into a fluid cooling coil, such as a MultiCool … |
| 1.3.6.1.4.1.318.1.1.13.1.4.3.12 | ScalarairFMSysCoilFluidVlvType | read-only | mandatory | The type of coil fluid valve installed for the Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to it… |
| 1.3.6.1.4.1.318.1.1.13.1.4.3.13 | ScalarairFMSysCndsrFluidVlvAct | read-only | mandatory | The type of valve actuator installed on the Condenser fluid valve. The Condenser fluid valve controls the flow of coolant into the heat exchanger (condenser) t… |
| 1.3.6.1.4.1.318.1.1.13.1.4.3.14 | ScalarairFMSysCndsrFluidVlvType | read-only | mandatory | The type of Condenser fluid valve installed for the Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due … |
| 1.3.6.1.4.1.318.1.1.13.1.4.3.15 | ScalarairFMSysHotWaterVlvAct | read-only | mandatory | The type of valve actuator installed on the hot water valve. A value of notApplicable indicates that this OID does not apply to this device due to its configur… |
| 1.3.6.1.4.1.318.1.1.13.1.4.3.16 | ScalarairFMSysNumRemoteSensors | read-only | mandatory | The number of remote sensors detected by the system. |
| 1.3.6.1.4.1.318.1.1.13.1.4.4 | NodeairFMSysConfig | |||
| 1.3.6.1.4.1.318.1.1.13.1.4.4.1 | ScalarairFMSysPrimaryControlSensor | read-write | mandatory | Selects whether return or remote sensors will control the system. A value of notApplicable indicates that this OID does not apply to this device due to its con… |
| 1.3.6.1.4.1.318.1.1.13.1.4.4.2 | ScalarairFMSysRemoteSensorData | read-write | mandatory | Selects whether average temperature or max temperature will be used when remote sensors are selected for control of the system. A value of notApplicable indica… |
| 1.3.6.1.4.1.318.1.1.13.1.4.4.3 | ScalarairFMSysFastStartup | read-write | mandatory | Minimizes the time for the cooling process to begin after other delay constraints have been met. A value of notApplicable indicates that this OID does not appl… |
| 1.3.6.1.4.1.318.1.1.13.1.4.4.4 | ScalarairFMSysStartupDelay | read-write | mandatory | Set the delay that begins when power is applied and ends when the System starts. This allows you to create a staged restart among your Systems after a power lo… |
| 1.3.6.1.4.1.318.1.1.13.1.4.4.5 | ScalarairFMSysModeDelay | read-write | mandatory | Set the delay between starting the blowers and engaging the modes. It allows the sensors to read room conditions accurately and allows the controller to check … |
| 1.3.6.1.4.1.318.1.1.13.1.4.4.6 | ScalarairFMSysCommLossShutdownDelay | read-write | mandatory | Set the delay between an Expansion Module losing communication with the Main Module and the Expansion Module shutting down. A value of -1 will keep the Expansi… |
| 1.3.6.1.4.1.318.1.1.13.1.4.4.7 | ScalarairFMSysResetSysFailure | read-write | mandatory | Setting this OID to reset(2) will allows the system to return from any failure condition, if the failure(s) have cleared. Getting this OID will do nothing and … |
| 1.3.6.1.4.1.318.1.1.13.1.4.4.8 | ScalarairFMSysResetUserDflts | read-write | mandatory | Setting this OID to reset(2) will reset all system parameters that can be edited by the user to their factory default values. Getting this OID will do nothing … |
| 1.3.6.1.4.1.318.1.1.13.1.4.4.9 | ScalarairFMSysResetFldSrvcDflts | read-write | mandatory | Setting this OID to reset(2) will reset all system parameters that can only be edited by the field service engineer to their factory default values. Getting th… |
| 1.3.6.1.4.1.318.1.1.13.1.4.4.10 | ScalarairFMSysResetRunHours | read-write | mandatory | Setting this OID to reset(2) will reset the system Run Hours. Getting this OID will do nothing and return the noOperation(1) value. A value of notApplicable in… |
| 1.3.6.1.4.1.318.1.1.13.1.4.5 | NodeairFMSysCooling | |||
| 1.3.6.1.4.1.318.1.1.13.1.4.5.1 | ScalarairFMSysCompMinOnTime | read-write | mandatory | Set the minimum time the compressor continues to operate after it is started. The delay protects the compressor from damage. Caution: Reducing this delay short… |
| 1.3.6.1.4.1.318.1.1.13.1.4.5.2 | ScalarairFMSysCompMinOffTime | read-write | mandatory | Set the minimum time the compressor will remain off after it ceases operation. The delay protects the compressor from damage. Caution: Reducing this delay shor… |
| 1.3.6.1.4.1.318.1.1.13.1.4.5.3 | ScalarairFMSysCompRotPeriod | read-write | mandatory | Set how often to perform compressor runtime balancing. Measured in hours. A value of -2147483648 indicates that this OID does not apply to this device due to i… |
| 1.3.6.1.4.1.318.1.1.13.1.4.5.4 | ScalarairFMSysEconIsolVlvOpenDelay | read-write | mandatory | Set the delay between opening the Economizer Isolator output relay and engaging the compressors. Measured in seconds. A value of -2147483648 indicates that thi… |
| 1.3.6.1.4.1.318.1.1.13.1.4.5.5 | ScalarairFMSysEconIsolVlvCloseDelay | read-write | mandatory | Set the delay between disengaging the compressor and closing the Economizer Isolator output relay. Measured in seconds. A value of -2147483648 indicates that t… |
| 1.3.6.1.4.1.318.1.1.13.1.4.5.6 | ScalarairFMSysCndsrFluidVlvCloseDelay | read-write | mandatory | Set the time the condenser valve remains open after the compressors disengage. Measured in seconds. A value of -2147483648 indicates that this OID does not app… |
| 1.3.6.1.4.1.318.1.1.13.1.4.5.7 | ScalarairFMSysInterstageDelay | read-write | mandatory | The DX interstage delay allows the first compressor's cooling to take effect before engaging the second compressor. This prevents the second compressor from cy… |
| 1.3.6.1.4.1.318.1.1.13.1.4.5.8 | ScalarairFMSysCoolState | read-write | mandatory | Set the mode to enabled or disabled. Disabled modes will not operate, and you cannot make changes to their settings while they are disabled. A value of notAppl… |
| 1.3.6.1.4.1.318.1.1.13.1.4.5.9 | ScalarairFMSysCoolEssFunction | read-write | mandatory | Set the priority of the mode for alarms and events with the nonessential stop behavior. Nonessential modes are disabled during nonessential stop alarms and eve… |
| 1.3.6.1.4.1.318.1.1.13.1.4.5.10 | ScalarairFMSysCoolSetpointC | read-write | mandatory | The target value for the selected control sensor air for this mode. It must be at least 1.0 C above the reheat setpoint if a heater is installed. Measured in t… |
| 1.3.6.1.4.1.318.1.1.13.1.4.5.11 | ScalarairFMSysCoolSetpointF | read-write | mandatory | The target value for the selected control sensor air for this mode. It must be at least 1.0 C above the reheat setpoint if a heater is installed. Measured in t… |
| 1.3.6.1.4.1.318.1.1.13.1.4.5.12 | ScalarairFMSysCoolDeadbandC | read-write | mandatory | The temperature range that controls output when the selected control sensor temperature is above the setpoint. At the top of this range, the cool mode outputs … |
| 1.3.6.1.4.1.318.1.1.13.1.4.5.13 | ScalarairFMSysCoolDeadbandF | read-write | mandatory | The temperature range that controls output when the selected control sensor temperature is above the setpoint. At the top of this range, the cool mode outputs … |
| 1.3.6.1.4.1.318.1.1.13.1.4.5.14 | ScalarairFMSysCoolEconIsolFunction | read-write | mandatory | Set the Economizer Automatic Coolant Isolation valve to enabled or disabled. This valve anticipates a cooling demand and opens the coil fluid valve. A value of… |
| 1.3.6.1.4.1.318.1.1.13.1.4.5.15 | ScalarairFMSysSuctPresCompensation | read-write | mandatory | Set the Suction Pressure Compensation to enabled or disabled. This function attempts to keep the suction pressure from exceeding 95 psi. A value of notApplicab… |
| 1.3.6.1.4.1.318.1.1.13.1.4.5.16 | ScalarairFMSysCoilFluidActivThreshC | read-write | mandatory | The minimum coolant temperature required to use the optional MultiCool or Economizer coil. Measured in tenths of degrees Celsius. A value of -2147483648 indica… |
| 1.3.6.1.4.1.318.1.1.13.1.4.5.17 | ScalarairFMSysCoilFluidActivThreshF | read-write | mandatory | The minimum coolant temperature required to use the optional MultiCool or Economizer coil. Measured in tenths of degrees Fahrenheit. A value of -2147483648 ind… |
| 1.3.6.1.4.1.318.1.1.13.1.4.5.18 | ScalarairFMSysCoilFluidActivDeadbandC | read-write | mandatory | The controller will disengage the MultiCool or Economizer coil when the coolant temperature reaches the coil fluid temperature activation threshold plus the de… |
| 1.3.6.1.4.1.318.1.1.13.1.4.5.19 | ScalarairFMSysCoilFluidActivDeadbandF | read-write | mandatory | The controller will disengage the MultiCool or Economizer coil when the coolant temperature reaches the coil fluid temperature activation threshold plus the de… |
| 1.3.6.1.4.1.318.1.1.13.1.4.5.20 | ScalarairFMSysCoolPIDMethod | read-write | mandatory | Set the multipliers that the PID algorithm will use to calculate the cool output. Proportional, Proportional + Integral, or Proportional + Integral + Derivativ… |
| 1.3.6.1.4.1.318.1.1.13.1.4.5.21 | ScalarairFMSysCoolPIDGainP | read-write | mandatory | Set the proportional multiplier to correct for differences between the selected control sensor actual temperature and the setpoint. Measured in %/C. A value of… |
| 1.3.6.1.4.1.318.1.1.13.1.4.5.22 | ScalarairFMSysCoolPIDResetRateI | read-write | mandatory | Set the integral multiplier to correct for the proportional offset. Measured in %/(C * min). A value of -2147483648 indicates that this OID does not apply to t… |
| 1.3.6.1.4.1.318.1.1.13.1.4.5.23 | ScalarairFMSysCoolPIDDerivativeD | read-write | mandatory | Set the derivative multiplier to counteract overshoot and droop during changes in the room load. Measured in %/(C / min). A value of -2147483648 indicates that… |
| 1.3.6.1.4.1.318.1.1.13.1.4.6 | NodeairFMSysHumidify | |||
| 1.3.6.1.4.1.318.1.1.13.1.4.6.1 | ScalarairFMSysHumState | read-write | mandatory | Set the mode to enabled or disabled. Disabled modes will not operate, and you cannot make changes to their settings while they are disabled. A value of notAppl… |
| 1.3.6.1.4.1.318.1.1.13.1.4.6.2 | ScalarairFMSysHumEssFunction | read-write | mandatory | Set the priority of the mode for alarms and events with the nonessential stop behavior. Nonessential modes are disabled during nonessential stop alarms and eve… |
| 1.3.6.1.4.1.318.1.1.13.1.4.6.3 | ScalarairFMSysHumSetpoint | read-write | mandatory | The target value for the selected control sensor air for this mode. It must be at least 1.0 % RH below the dehumidification setpoint. Measured in tenths of per… |
| 1.3.6.1.4.1.318.1.1.13.1.4.6.4 | ScalarairFMSysHumDeadband | read-write | mandatory | The humidity range that controls output when the selected control sensor humidity is below the setpoint. At the top of this range, the humidification mode outp… |
| 1.3.6.1.4.1.318.1.1.13.1.4.6.5 | ScalarairFMSysHumCtrlSetting | read-write | mandatory | Set the method to control the humidity in the room. The two methods are Relative Humidity (RH) or Dew Point of the selected control sensor air. The dew point m… |
| 1.3.6.1.4.1.318.1.1.13.1.4.6.6 | ScalarairFMSysActualHumCtrl | read-only | mandatory | The humidity control method the system is using. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.6.7 | ScalarairFMSysHumSensBand | read-write | mandatory | The percentage of relative humidity below the setpoint at which the humidifier will output at 100% of capacity. Measured in percent relative humidity. A value … |
| 1.3.6.1.4.1.318.1.1.13.1.4.7 | NodeairFMSysDehumidify | |||
| 1.3.6.1.4.1.318.1.1.13.1.4.7.1 | ScalarairFMSysDehumState | read-write | mandatory | Set the mode to enabled or disabled. Disabled modes will not operate, and you cannot make changes to their settings while they are disabled. A value of notAppl… |
| 1.3.6.1.4.1.318.1.1.13.1.4.7.2 | ScalarairFMSysDehumEssFunction | read-write | mandatory | Set the priority of the mode for alarms and events with the nonessential stop behavior. Nonessential modes are disabled during nonessential stop alarms and eve… |
| 1.3.6.1.4.1.318.1.1.13.1.4.7.3 | ScalarairFMSysDehumSetpoint | read-write | mandatory | The target value for the selected control sensor air for this mode. It must be at least 1.0 % RH above the humidification setpoint if a humidifier is installed… |
| 1.3.6.1.4.1.318.1.1.13.1.4.7.4 | ScalarairFMSysDehumDeadband | read-write | mandatory | The humidity range above the setpoint at which the dehumidification mode will output at 100%. The deadband does not apply to PID controlled modes. Measured in … |
| 1.3.6.1.4.1.318.1.1.13.1.4.7.5 | ScalarairFMSysDehumCapacity | read-write | mandatory | Set the dehumidification mode to use either half of the cooling coil or the full coil when dehumidifying the room. A value of notApplicable indicates that this… |
| 1.3.6.1.4.1.318.1.1.13.1.4.7.6 | ScalarairFMSysDehumPIDMethod | read-write | mandatory | Set the multipliers that the PID algorithm will use to calculate the output. Proportional, Proportional + Integral, or Proportional + Integral + Derivative. A … |
| 1.3.6.1.4.1.318.1.1.13.1.4.7.7 | ScalarairFMSysDehumPIDGainP | read-write | mandatory | Set the proportional multiplier to correct for differences between the selected control sensor actual humidity and the setpoint. Measured in %/%RH. A value of … |
| 1.3.6.1.4.1.318.1.1.13.1.4.7.8 | ScalarairFMSysDehumPIDResetRateI | read-write | mandatory | Set the integral multiplier to correct for the proportional offset. Measured in %/(%RH * min). A value of -2147483648 indicates that this OID does not apply to… |
| 1.3.6.1.4.1.318.1.1.13.1.4.7.9 | ScalarairFMSysDehumPIDDerivativeD | read-write | mandatory | Set the derivative multiplier to counteract overshoot and droop during changes in the room humidity. Measure in %/(%RH / min). A value of -2147483648 indicates… |
| 1.3.6.1.4.1.318.1.1.13.1.4.8 | NodeairFMSysReheat | |||
| 1.3.6.1.4.1.318.1.1.13.1.4.8.1 | ScalarairFMSysReheatState | read-write | mandatory | Set the mode to enabled or disabled. Disabled modes will not operate, and you cannot make changes to their settings while they are disabled. A value of notAppl… |
| 1.3.6.1.4.1.318.1.1.13.1.4.8.2 | ScalarairFMSysReheatEssFunction | read-write | mandatory | Set the priority of the mode for alarms and events with the nonessential stop behavior. Nonessential modes are disabled during nonessential stop alarms and eve… |
| 1.3.6.1.4.1.318.1.1.13.1.4.8.3 | ScalarairFMSysReheatSetpointC | read-write | mandatory | The target value for the selected control sensor air for this mode. It must be at least 1.0 C below the cooling setpoint. Measured in tenths of degrees Celsius… |
| 1.3.6.1.4.1.318.1.1.13.1.4.8.4 | ScalarairFMSysReheatSetpointF | read-write | mandatory | The target value for the selected control sensor air for this mode. It must be at least 1.0 C below the cooling setpoint. Measured in tenths of degrees Fahrenh… |
| 1.3.6.1.4.1.318.1.1.13.1.4.8.5 | ScalarairFMSysReheatDeadbandC | read-write | mandatory | The temperature range that controls output when the selected control sensor temperature is below the setpoint. At the bottom of this range, the reheat mode out… |
| 1.3.6.1.4.1.318.1.1.13.1.4.8.6 | ScalarairFMSysReheatDeadbandF | read-write | mandatory | The temperature range that controls output when the selected control sensor temperature is below the setpoint. At the bottom of this range, the reheat mode out… |
| 1.3.6.1.4.1.318.1.1.13.1.4.8.7 | ScalarairFMSysReheatPIDMethod | read-write | mandatory | Set the multipliers that the PID algorithm will use to calculate the output. Proportional, Proportional + Integral, or Proportional + Integral + Derivative. A … |
| 1.3.6.1.4.1.318.1.1.13.1.4.8.8 | ScalarairFMSysReheatPIDGainP | read-write | mandatory | Set the proportional multiplier to correct for differences between the selected control sensor actual temperature and the setpoint. Measured in %/C. A value of… |
| 1.3.6.1.4.1.318.1.1.13.1.4.8.9 | ScalarairFMSysReheatPIDResetRateI | read-write | mandatory | Set the integral multiplier to correct for the proportional offset. Measured in %/(C * min). A value of -2147483648 indicates that this OID does not apply to t… |
| 1.3.6.1.4.1.318.1.1.13.1.4.8.10 | ScalarairFMSysReheatPIDDerivativeD | read-write | mandatory | Set the derivative multiplier to counteract overshoot and droop during changes in the room load. Measured in %/(C / min). A value of -2147483648 indicates that… |
| 1.3.6.1.4.1.318.1.1.13.1.4.9 | NodeairFMSysThresholds | |||
| 1.3.6.1.4.1.318.1.1.13.1.4.9.1 | ScalarairFMSysHighSplyTempC | read-write | mandatory | The high temperature threshold for air blown into the room (supply). If the supply temperature exceeds the threshold, an alarm will occur. Measured in tenths o… |
| 1.3.6.1.4.1.318.1.1.13.1.4.9.2 | ScalarairFMSysHighSplyTempF | read-write | mandatory | The high temperature threshold for air blown into the room (supply). If the supply temperature exceeds the threshold, an alarm will occur. Measured in tenths o… |
| 1.3.6.1.4.1.318.1.1.13.1.4.9.3 | ScalarairFMSysLowSplyTempC | read-write | mandatory | The low temperature threshold for air blown into the room (supply). If the supply temperature drops below the threshold, an alarm will occur. Measured in tenth… |
| 1.3.6.1.4.1.318.1.1.13.1.4.9.4 | ScalarairFMSysLowSplyTempF | read-write | mandatory | The low temperature threshold for air blown into the room (supply). If the supply temperature drops below the threshold, an alarm will occur. Measured in tenth… |
| 1.3.6.1.4.1.318.1.1.13.1.4.9.5 | ScalarairFMSysHighCoilFluidTempC | read-write | mandatory | The high temperature threshold for coolant at the inlet to the fluid coil. If the fluid coil coolant temperature exceeds the threshold, an alarm will occur. Me… |
| 1.3.6.1.4.1.318.1.1.13.1.4.9.6 | ScalarairFMSysHighCoilFluidTempF | read-write | mandatory | The high temperature threshold for coolant at the inlet to the fluid coil. If the fluid coil coolant temperature exceeds the threshold, an alarm will occur. Me… |
| 1.3.6.1.4.1.318.1.1.13.1.4.9.7 | ScalarairFMSysLowCoilFluidTempC | read-write | mandatory | The low temperature threshold for coolant at the inlet to the fluid coil. If the fluid coil coolant temperature drops below the threshold, an alarm will occur.… |
| 1.3.6.1.4.1.318.1.1.13.1.4.9.8 | ScalarairFMSysLowCoilFluidTempF | read-write | mandatory | The low temperature threshold for coolant at the inlet to the fluid coil. If the fluid coil coolant temperature drops below the threshold, an alarm will occur.… |
| 1.3.6.1.4.1.318.1.1.13.1.4.9.9 | ScalarairFMSysHighCtrlTempC | read-write | mandatory | The high temperature threshold for air monitored by the System. If the temperature exceeds the threshold, an alarm will occur. Measured in tenths of degrees Ce… |
| 1.3.6.1.4.1.318.1.1.13.1.4.9.10 | ScalarairFMSysHighCtrlTempF | read-write | mandatory | The high temperature threshold for air monitored by the System. If the temperature exceeds the threshold, an alarm will occur. Measured in tenths of degrees Fa… |
| 1.3.6.1.4.1.318.1.1.13.1.4.9.11 | ScalarairFMSysLowCtrlTempC | read-write | mandatory | The low temperature threshold for air monitored by the System. If the temperature drops below the threshold, an alarm will occur. Measured in tenths of degrees… |
| 1.3.6.1.4.1.318.1.1.13.1.4.9.12 | ScalarairFMSysLowCtrlTempF | read-write | mandatory | The low temperature threshold for air monitored by the System. If the temperature drops below the threshold, an alarm will occur. Measured in tenths of degrees… |
| 1.3.6.1.4.1.318.1.1.13.1.4.9.13 | ScalarairFMSysHighCtrlHum | read-write | mandatory | The high humidity threshold for air monitored by the System. If the humidity exceeds the threshold, an alarm will occur. Measured in tenths of percent relative… |
| 1.3.6.1.4.1.318.1.1.13.1.4.9.14 | ScalarairFMSysLowCtrlHum | read-write | mandatory | The low humidity threshold for air monitored by the System. If the humidity drops below the threshold, an alarm will occur. Measured in tenths of percent relat… |
| 1.3.6.1.4.1.318.1.1.13.1.4.9.15 | ScalarairFMSysTempAlarmDelay | read-write | mandatory | The amount of time the blower must be on before a temperature alarm can be issued. Measured in seconds. A value of -2147483648 indicates that this OID does not… |
| 1.3.6.1.4.1.318.1.1.13.1.4.9.16 | ScalarairFMSysHumAlarmDelay | read-write | mandatory | The amount of time the blower must be on before a humidity alarm can be issued. Measured in seconds. A value of -2147483648 indicates that this OID does not ap… |
| 1.3.6.1.4.1.318.1.1.13.1.4.10 | NodeairFMSysInputs | |||
| 1.3.6.1.4.1.318.1.1.13.1.4.10.1 | ScalarairFMSysInputTableSize | read-only | mandatory | The number of entries in the airFMSysInputTable. |
| 1.3.6.1.4.1.318.1.1.13.1.4.10.2 | TableairFMSysInputTable | not-accessible | mandatory | Allows for getting information from each input contact. |
| 1.3.6.1.4.1.318.1.1.13.1.4.10.2.1 | RowairFMSysInputEntry | not-accessible | mandatory | The input contact to obtain status from. |
| 1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.1 | ColumnairFMSysInputIndex | read-only | mandatory | The number designator of the Input Contact. |
| 1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.2 | ColumnairFMSysInputName | read-write | mandatory | The configurable name for the Input Contact. Maximum text input is 13 characters. |
| 1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.3 | ColumnairFMSysInputStatus | read-only | mandatory | The state of this contact: Open or Closed. A violation will occur when this relay is not in its normal state. |
| 1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.4 | ColumnairFMSysInputNormalState | read-write | mandatory | Set the normal state of this contact (the state when no alarm/event exists). |
| 1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.5 | ColumnairFMSysInputDelay | read-write | mandatory | Set the delay between this contact exiting its normal state and an alarm being triggered. Measured in seconds. |
| 1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.6 | ColumnairFMSysInputAlarmAction | read-write | mandatory | Sets the behavior for this contact when it exits its normal state. |
| 1.3.6.1.4.1.318.1.1.13.1.4.11 | NodeairFMSysOutputs | |||
| 1.3.6.1.4.1.318.1.1.13.1.4.11.1 | ScalarairFMSysOutputTableSize | read-only | mandatory | The number of entries in the airFMSysOutputTable. |
| 1.3.6.1.4.1.318.1.1.13.1.4.11.2 | TableairFMSysOutputTable | not-accessible | mandatory | Allows for getting information from each output relay. |
| 1.3.6.1.4.1.318.1.1.13.1.4.11.2.1 | RowairFMSysOutputEntry | not-accessible | mandatory | The output relay to obtain status from. |
| 1.3.6.1.4.1.318.1.1.13.1.4.11.2.1.1 | ColumnairFMSysOutputIndex | read-only | mandatory | The number designator of the output relay. |
| 1.3.6.1.4.1.318.1.1.13.1.4.11.2.1.2 | ColumnairFMSysOutputStatus | read-only | mandatory | The state of this relay: Open or Closed. A violation will occur when this relay is not in its normal state. |
| 1.3.6.1.4.1.318.1.1.13.1.4.11.2.1.3 | ColumnairFMSysOutputNormalState | read-write | mandatory | Set the normal state of this relay (the state when no alarm/event exists). |
| 1.3.6.1.4.1.318.1.1.13.1.4.12 | NodeairFMSysAlarmMap | |||
| 1.3.6.1.4.1.318.1.1.13.1.4.12.1 | NodeairFMSysAlarmMapSys | |||
| 1.3.6.1.4.1.318.1.1.13.1.4.12.1.1 | ScalarairFMSysAlarmMapSysTableSize | read-only | mandatory | The number of entries in the airFMSysAlarmMapSysTable. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2 | TableairFMSysAlarmMapSysTable | not-accessible | mandatory | Allows for getting alarm map information. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1 | RowairFMSysAlarmMapSysEntry | not-accessible | mandatory | The system alarm map type to reference. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.1 | ColumnairFMSysAlarmMapSysOutputIndex | read-only | mandatory | The index of the output relay. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.2 | ColumnairFMSysAlarmMapSysAnyAlarm | read-write | mandatory | System alarm map setting for Any Alarm. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.3 | ColumnairFMSysAlarmMapSystemOn | read-write | mandatory | System alarm map setting for System On. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.4 | ColumnairFMSysAlarmMapSystemOffline | read-write | mandatory | System alarm map setting for System Offline. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.5 | ColumnairFMSysAlarmMapSysHighEnvTemp | read-write | mandatory | System alarm map setting for High Environmental Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configur… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.6 | ColumnairFMSysAlarmMapSysLowEnvTemp | read-write | mandatory | System alarm map setting for Low Environmental Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configura… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.7 | ColumnairFMSysAlarmMapSysHighEnvHum | read-write | mandatory | System alarm map setting for High Environmental Humidity. A value of notApplicable indicates that this OID does not apply to this device due to its configurati… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.8 | ColumnairFMSysAlarmMapSysLowEnvHum | read-write | mandatory | System alarm map setting for Low Environmental Humidity. A value of notApplicable indicates that this OID does not apply to this device due to its configuratio… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.9 | ColumnairFMSysAlarmMapSysFireDet | read-write | mandatory | System alarm map setting for Fire Detected. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.10 | ColumnairFMSysAlarmMapSysSmokeDet | read-write | mandatory | System alarm map setting for Smoke Detected. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.11 | ColumnairFMSysAlarmMapSysEconIsol | read-write | mandatory | System alarm map setting for Econ Isolator. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.12 | ColumnairFMSysAlarmMapSysSupplySensFail | read-write | mandatory | System alarm map setting for Supply Sensor Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.13 | ColumnairFMSysAlarmMapSysReturnSensFail | read-write | mandatory | System alarm map setting for Return Sensor Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.14 | ColumnairFMSysAlarmMapSysRemSensRemoved | read-write | mandatory | System alarm map setting for Remote Sensor Removed. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.15 | ColumnairFMSysAlarmMapSysPrimSensFail | read-write | mandatory | System alarm map setting for Primary Sensor Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.16 | ColumnairFMSysAlarmMapSysSecSensFail | read-write | mandatory | System alarm map setting for Secondary Sensor Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.17 | ColumnairFMSysAlarmMapSysSecSensActive | read-write | mandatory | System alarm map setting for Secondary Sensor Active. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.2 | NodeairFMSysAlarmMapMainMod | |||
| 1.3.6.1.4.1.318.1.1.13.1.4.12.2.1 | ScalarairFMSysAlarmMapMainModTableSize | read-only | mandatory | The number of entries in the airFMSysAlarmMapMainModTable. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2 | TableairFMSysAlarmMapMainModTable | not-accessible | mandatory | Allows for getting alarm map information. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1 | RowairFMSysAlarmMapMainModEntry | not-accessible | mandatory | The main module alarm map type to reference. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.1 | ColumnairFMSysAlarmMapMainModOutputIndex | read-only | mandatory | The index of the output relay. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.2 | ColumnairFMSysAlarmMapMainModAnyAlarm | read-write | mandatory | Main Module alarm map setting for Any Alarm. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.3 | ColumnairFMSysAlarmMapMainModMaintReq | read-write | mandatory | Main Module alarm map setting for Module Maintenance Required. A value of notApplicable indicates that this OID does not apply to this device due to its config… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.4 | ColumnairFMSysAlarmMapMainModCoolFail | read-write | mandatory | Main Module alarm map setting for Module Cooling Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configurati… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.5 | ColumnairFMSysAlarmMapMainModHighSupplyTemp | read-write | mandatory | Main Module alarm map setting for High Supply Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configurat… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.6 | ColumnairFMSysAlarmMapMainModLowSupplyTemp | read-write | mandatory | Main Module alarm map setting for Low Supply Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configurati… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.7 | ColumnairFMSysAlarmMapMainModHumFail | read-write | mandatory | Main Module alarm map setting for Humidifier Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.8 | ColumnairFMSysAlarmMapMainModHumReplCyl | read-write | mandatory | Main Module alarm map setting for Humidifier Replace Cylinder. A value of notApplicable indicates that this OID does not apply to this device due to its config… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.9 | ColumnairFMSysAlarmMapMainModCondPumpFail | read-write | mandatory | Main Module alarm map setting for Condensate Pump Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configurat… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.10 | ColumnairFMSysAlarmMapMainModBlwrCntl1Fail | read-write | mandatory | Main Module alarm map setting for Blower Controller 1 Failure. A value of notApplicable indicates that this OID does not apply to this device due to its config… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.11 | ColumnairFMSysAlarmMapMainModBlwrCntl2Fail | read-write | mandatory | Main Module alarm map setting for Blower Controller 2 Failure. A value of notApplicable indicates that this OID does not apply to this device due to its config… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.12 | ColumnairFMSysAlarmMapMainModHighFltrDP | read-write | mandatory | Main Module alarm map setting for High Filter Differential Pressure. A value of notApplicable indicates that this OID does not apply to this device due to its … |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.13 | ColumnairFMSysAlarmMapMainModLowAirFlow | read-write | mandatory | Main Module alarm map setting for Low Air Flow. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.14 | ColumnairFMSysAlarmMapMainModAirBlckIntOpen | read-write | mandatory | Main Module alarm map setting for Air Block Interlock Open. A value of notApplicable indicates that this OID does not apply to this device due to its configura… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.15 | ColumnairFMSysAlarmMapMainModWaterDetected | read-write | mandatory | Main Module alarm map setting for Water Detected. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.3 | NodeairFMSysAlarmMapExpMod1 | |||
| 1.3.6.1.4.1.318.1.1.13.1.4.12.3.1 | ScalarairFMSysAlarmMapExpMod1TableSize | read-only | mandatory | The number of entries in the airFMSysAlarmMapExpMod1Table. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2 | TableairFMSysAlarmMapExpMod1Table | not-accessible | mandatory | Allows for getting alarm map information. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1 | RowairFMSysAlarmMapExpMod1Entry | not-accessible | mandatory | The expansion module 1 alarm map type to reference. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.1 | ColumnairFMSysAlarmMapExpMod1OutputIndex | read-only | mandatory | The index of the output relay. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.2 | ColumnairFMSysAlarmMapExpMod1AnyAlarm | read-write | mandatory | Exp Module 1 alarm map setting for Any Alarm. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.3 | ColumnairFMSysAlarmMapExpMod1MaintReq | read-write | mandatory | Exp Module 1 alarm map setting for Module Maintenance Required. A value of notApplicable indicates that this OID does not apply to this device due to its confi… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.4 | ColumnairFMSysAlarmMapExpMod1CoolFail | read-write | mandatory | Exp Module 1 alarm map setting for Module Cooling Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configurat… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.5 | ColumnairFMSysAlarmMapExpMod1HighSupplyTemp | read-write | mandatory | Exp Module 1 alarm map setting for High Supply Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configura… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.6 | ColumnairFMSysAlarmMapExpMod1LowSupplyTemp | read-write | mandatory | Exp Module 1 alarm map setting for Low Supply Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configurat… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.7 | ColumnairFMSysAlarmMapExpMod1HumFail | read-write | mandatory | Exp Module 1 alarm map setting for Humidifier Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.8 | ColumnairFMSysAlarmMapExpMod1HumReplCyl | read-write | mandatory | Exp Module 1 alarm map setting for Humidifier Replace Cylinder. A value of notApplicable indicates that this OID does not apply to this device due to its confi… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.9 | ColumnairFMSysAlarmMapExpMod1CondPumpFail | read-write | mandatory | Exp Module 1 alarm map setting for Condensate Pump Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configura… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.10 | ColumnairFMSysAlarmMapExpMod1BlwrCntl1Fail | read-write | mandatory | Exp Module 1 alarm map setting for Blower Controller 1 Failure. A value of notApplicable indicates that this OID does not apply to this device due to its confi… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.11 | ColumnairFMSysAlarmMapExpMod1BlwrCntl2Fail | read-write | mandatory | Exp Module 1 alarm map setting for Blower Controller 2 Failure. A value of notApplicable indicates that this OID does not apply to this device due to its confi… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.12 | ColumnairFMSysAlarmMapExpMod1HighFltrDP | read-write | mandatory | Exp Module 1 alarm map setting for High Filter Differential Pressure. A value of notApplicable indicates that this OID does not apply to this device due to its… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.13 | ColumnairFMSysAlarmMapExpMod1LowAirFlow | read-write | mandatory | Exp Module 1 alarm map setting for Low Air Flow. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.14 | ColumnairFMSysAlarmMapExpMod1AirBlckIntOpen | read-write | mandatory | Exp Module 1 alarm map setting for Air Block Interlock Open. A value of notApplicable indicates that this OID does not apply to this device due to its configur… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.15 | ColumnairFMSysAlarmMapExpMod1WaterDetected | read-write | mandatory | Exp Module 1 alarm map setting for Water Detected. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.4 | NodeairFMSysAlarmMapExpMod2 | |||
| 1.3.6.1.4.1.318.1.1.13.1.4.12.4.1 | ScalarairFMSysAlarmMapExpMod2TableSize | read-only | mandatory | The number of entries in the airFMSysAlarmMapExpMod2Table. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2 | TableairFMSysAlarmMapExpMod2Table | not-accessible | mandatory | Allows for getting alarm map information. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1 | RowairFMSysAlarmMapExpMod2Entry | not-accessible | mandatory | The expansion module 2 alarm map type to reference. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.1 | ColumnairFMSysAlarmMapExpMod2OutputIndex | read-only | mandatory | The index of the output relay. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.2 | ColumnairFMSysAlarmMapExpMod2AnyAlarm | read-write | mandatory | Exp Module 2 alarm map setting for Any Alarm. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.3 | ColumnairFMSysAlarmMapExpMod2MaintReq | read-write | mandatory | Exp Module 2 alarm map setting for Module Maintenance Required. A value of notApplicable indicates that this OID does not apply to this device due to its confi… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.4 | ColumnairFMSysAlarmMapExpMod2CoolFail | read-write | mandatory | Exp Module 2 alarm map setting for Module Cooling Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configurat… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.5 | ColumnairFMSysAlarmMapExpMod2HighSupplyTemp | read-write | mandatory | Exp Module 2 alarm map setting for High Supply Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configura… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.6 | ColumnairFMSysAlarmMapExpMod2LowSupplyTemp | read-write | mandatory | Exp Module 2 alarm map setting for Low Supply Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configurat… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.7 | ColumnairFMSysAlarmMapExpMod2HumFail | read-write | mandatory | Exp Module 2 alarm map setting for Humidifier Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.8 | ColumnairFMSysAlarmMapExpMod2HumReplCyl | read-write | mandatory | Exp Module 2 alarm map setting for Humidifier Replace Cylinder. A value of notApplicable indicates that this OID does not apply to this device due to its confi… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.9 | ColumnairFMSysAlarmMapExpMod2CondPumpFail | read-write | mandatory | Exp Module 2 alarm map setting for Condensate Pump Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configura… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.10 | ColumnairFMSysAlarmMapExpMod2BlwrCntl1Fail | read-write | mandatory | Exp Module 2 alarm map setting for Blower Controller 1 Failure. A value of notApplicable indicates that this OID does not apply to this device due to its confi… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.11 | ColumnairFMSysAlarmMapExpMod2BlwrCntl2Fail | read-write | mandatory | Exp Module 2 alarm map setting for Blower Controller 2 Failure. A value of notApplicable indicates that this OID does not apply to this device due to its confi… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.12 | ColumnairFMSysAlarmMapExpMod2HighFltrDP | read-write | mandatory | Exp Module 2 alarm map setting for High Filter Differential Pressure. A value of notApplicable indicates that this OID does not apply to this device due to its… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.13 | ColumnairFMSysAlarmMapExpMod2LowAirFlow | read-write | mandatory | Exp Module 2 alarm map setting for Low Air Flow. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.14 | ColumnairFMSysAlarmMapExpMod2AirBlckIntOpen | read-write | mandatory | Exp Module 2 alarm map setting for Air Block Interlock Open. A value of notApplicable indicates that this OID does not apply to this device due to its configur… |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.15 | ColumnairFMSysAlarmMapExpMod2WaterDetected | read-write | mandatory | Exp Module 2 alarm map setting for Water Detected. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.5 | NodeairFMSysAlarmMapInput | |||
| 1.3.6.1.4.1.318.1.1.13.1.4.12.5.1 | ScalarairFMSysAlarmMapInputTableSize | read-only | mandatory | The number of entries in the airFMSysAlarmMapInputTable. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2 | TableairFMSysAlarmMapInputTable | not-accessible | mandatory | Allows for getting alarm map information. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1 | RowairFMSysAlarmMapInputEntry | not-accessible | mandatory | The input contact alarm map type to reference. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.1 | ColumnairFMSysAlarmMapInputOutputIndex | read-only | mandatory | The index of the output relay. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.2 | ColumnairFMSysAlarmMapInput1 | read-write | mandatory | Input contact 1 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.3 | ColumnairFMSysAlarmMapInput2 | read-write | mandatory | Input contact 2 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.4 | ColumnairFMSysAlarmMapInput3 | read-write | mandatory | Input contact 3 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.5 | ColumnairFMSysAlarmMapInput4 | read-write | mandatory | Input contact 4 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.6 | ColumnairFMSysAlarmMapInput5 | read-write | mandatory | Input contact 5 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.7 | ColumnairFMSysAlarmMapInput6 | read-write | mandatory | Input contact 6 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.8 | ColumnairFMSysAlarmMapInput7 | read-write | mandatory | Input contact 7 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.9 | ColumnairFMSysAlarmMapInput8 | read-write | mandatory | Input contact 8 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.10 | ColumnairFMSysAlarmMapInput9 | read-write | mandatory | Input contact 9 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.11 | ColumnairFMSysAlarmMapInput10 | read-write | mandatory | Input contact 10 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.12 | ColumnairFMSysAlarmMapInput11 | read-write | mandatory | Input contact 11 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.13 | ColumnairFMSysAlarmMapInput12 | read-write | mandatory | Input contact 12 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.14 | ColumnairFMSysAlarmMapInput13 | read-write | mandatory | Input contact 13 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.15 | ColumnairFMSysAlarmMapInput14 | read-write | mandatory | Input contact 14 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.16 | ColumnairFMSysAlarmMapInput15 | read-write | mandatory | Input contact 15 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.17 | ColumnairFMSysAlarmMapInput16 | read-write | mandatory | Input contact 16 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.6 | NodeairFMSysAlarmMapOutput | |||
| 1.3.6.1.4.1.318.1.1.13.1.4.12.6.1 | ScalarairFMSysAlarmMapOutputTableSize | read-only | mandatory | The number of entries in the airFMSysAlarmMapOutputTable. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2 | TableairFMSysAlarmMapOutputTable | not-accessible | mandatory | Allows for getting alarm map information. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1 | RowairFMSysAlarmMapOutputEntry | not-accessible | mandatory | The input contact alarm map type to reference. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.1 | ColumnairFMSysAlarmMapOutputIndex | read-only | mandatory | The index of the output relay. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.2 | ColumnairFMSysAlarmMapOutput1 | read-write | mandatory | Output relay 1 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.3 | ColumnairFMSysAlarmMapOutput2 | read-write | mandatory | Output relay 2 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.4 | ColumnairFMSysAlarmMapOutput3 | read-write | mandatory | Output relay 3 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.5 | ColumnairFMSysAlarmMapOutput4 | read-write | mandatory | Output relay 4 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.6 | ColumnairFMSysAlarmMapOutput5 | read-write | mandatory | Output relay 5 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.7 | ColumnairFMSysAlarmMapOutput6 | read-write | mandatory | Output relay 6 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.8 | ColumnairFMSysAlarmMapOutput7 | read-write | mandatory | Output relay 7 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.9 | ColumnairFMSysAlarmMapOutput8 | read-write | mandatory | Output relay 8 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.10 | ColumnairFMSysAlarmMapOutput9 | read-write | mandatory | Output relay 9 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.11 | ColumnairFMSysAlarmMapOutput10 | read-write | mandatory | Output relay 10 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.12 | ColumnairFMSysAlarmMapOutput11 | read-write | mandatory | Output relay 11 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.13 | ColumnairFMSysAlarmMapOutput12 | read-write | mandatory | Output relay 12 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.14 | ColumnairFMSysAlarmMapOutput13 | read-write | mandatory | Output relay 13 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.15 | ColumnairFMSysAlarmMapOutput14 | read-write | mandatory | Output relay 14 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.16 | ColumnairFMSysAlarmMapOutput15 | read-write | mandatory | Output relay 15 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.17 | ColumnairFMSysAlarmMapOutput16 | read-write | mandatory | Output relay 16 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.5 | NodeairFMModule | |||
| 1.3.6.1.4.1.318.1.1.13.1.5.1 | NodeairFMModIdent | |||
| 1.3.6.1.4.1.318.1.1.13.1.5.1.1 | ScalarairFMModIdentTableSize | read-only | mandatory | The number of entries in the airFMModIdentTable. |
| 1.3.6.1.4.1.318.1.1.13.1.5.1.2 | TableairFMModIdentTable | not-accessible | mandatory | Allows for getting information from each module in the system. |
| 1.3.6.1.4.1.318.1.1.13.1.5.1.2.1 | RowairFMModIdentEntry | not-accessible | mandatory | The module to get information from. |
| 1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.1 | ColumnairFMModIdentModuleIndex | read-only | mandatory | The index of the module. |
| 1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.2 | ColumnairFMModModelNumber | read-only | mandatory | Model number of the Module. |
| 1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.3 | ColumnairFMModSerialNumber | read-only | mandatory | Unique identification number for this Module. |
| 1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.4 | ColumnairFMModManufactureDate | read-only | mandatory | Date the Module was manufactured. |
| 1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.5 | ColumnairFMModFirmwareRev | read-only | mandatory | Revision number of the firmware installed on this Module. |
| 1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.6 | ColumnairFMModHardwareRev | read-only | mandatory | Revision number of the hardware installed on this Module. |
| 1.3.6.1.4.1.318.1.1.13.1.5.2 | NodeairFMModStatus | |||
| 1.3.6.1.4.1.318.1.1.13.1.5.2.1 | ScalarairFMModStatusTableSize | read-only | mandatory | The number of entries in the airFMModStatusTable. |
| 1.3.6.1.4.1.318.1.1.13.1.5.2.2 | TableairFMModStatusTable | not-accessible | mandatory | Allows for getting information from each module in the system. |
| 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1 | RowairFMModStatusEntry | not-accessible | mandatory | The module to get information from. |
| 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.1 | ColumnairFMModStatusModuleIndex | read-only | mandatory | The index of the module. |
| 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.2 | ColumnairFMModSupplyTempC | read-only | mandatory | The temperature measured at the supply sensor. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this dev… |
| 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.3 | ColumnairFMModSupplyTempF | read-only | mandatory | The temperature measured at the supply sensor. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this … |
| 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.4 | ColumnairFMModSupplyHum | read-only | mandatory | The humidity measured at the supply sensor. Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to t… |
| 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.5 | ColumnairFMModReturnTempC | read-only | mandatory | The temperature measured at the return sensor. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this dev… |
| 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.6 | ColumnairFMModReturnTempF | read-only | mandatory | The temperature measured at the return sensor. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this … |
| 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.7 | ColumnairFMModReturnHum | read-only | mandatory | The humidity measured at the return sensor. Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to t… |
| 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.8 | ColumnairFMModFilterDiffPresPa | read-only | mandatory | The difference in pressure on either side of the air filters. A high differential pressure indicates a clogged filter. Measured in Pascals. A value of -2147483… |
| 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.9 | ColumnairFMModFilterDiffPresInWC | read-only | mandatory | The difference in pressure on either side of the air filters. A high differential pressure indicates a clogged filter. Measured in hundredths of inches water c… |
| 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.10 | ColumnairFMModCoilDiffPresPa | read-only | mandatory | The difference in pressure on either side of the cooling/dehumidification coils. Measured in Pascals. A value of -2147483648 indicates that this OID does not a… |
| 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.11 | ColumnairFMModCoilDiffPresInWC | read-only | mandatory | The difference in pressure on either side of the cooling/dehumidification coils. Measured in hundredths of inches water column. A value of -2147483648 indicate… |
| 1.3.6.1.4.1.318.1.1.13.1.5.3 | NodeairFMModProperties | |||
| 1.3.6.1.4.1.318.1.1.13.1.5.3.1 | ScalarairFMModPropTableSize | read-only | mandatory | The number of entries in the airFMModPropTable. |
| 1.3.6.1.4.1.318.1.1.13.1.5.3.2 | TableairFMModPropTable | not-accessible | mandatory | Allows for getting information from each module in the system. |
| 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1 | RowairFMModPropEntry | not-accessible | mandatory | The module to get information from. |
| 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.1 | ColumnairFMModPropModuleIndex | read-only | mandatory | The index of the module. |
| 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.2 | ColumnairFMModOutputCapacity | read-only | mandatory | The cooling capacity (in Kilowatts) of the displayed Module. A value of notApplicable indicates that this OID does not apply to this device due to its configur… |
| 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.3 | ColumnairFMModCapacityCtrl | read-only | mandatory | The method used to load and unload the compressors. Tandem compressor Modules use two stages (one compressor each). Single compressor Modules use hot gas bypas… |
| 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.4 | ColumnairFMModHeaterType | read-only | mandatory | The type of reheating device installed in this Module. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.5 | ColumnairFMModElectricHeaterType | read-only | mandatory | The type/capacity of the electric heater, if installed. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.6 | ColumnairFMModHumidifierType | read-only | mandatory | The type of equipment installed in the Module to run the humidification mode. A value of notApplicable indicates that this OID does not apply to this device du… |
| 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.7 | ColumnairFMModBlwrFreqSetting | read-only | mandatory | Frequency of the blower in tenths of hertz. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.8 | ColumnairFMModNomCoilDiffPresPa | read-only | mandatory | The difference in pressure on either side of the cooling/dehumidification coils. Measured in Pascals. A value of -2147483648 indicates that this OID does not a… |
| 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.9 | ColumnairFMModNomCoilDiffPresInWC | read-only | mandatory | The difference in pressure on either side of the cooling/dehumidification coils. Measured in hundredths of inches water column. A value of -2147483648 indicate… |
| 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.10 | ColumnairFMModCondPump | read-only | mandatory | Indicates the presence of a condensate pump in the Modules of this System. A value of notApplicable indicates that this OID does not apply to this device due t… |
| 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.11 | ColumnairFMModFireDetector | read-only | mandatory | Indicates the presence of a fire detector for each of the Modules in this System. A value of notApplicable indicates that this OID does not apply to this devic… |
| 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.12 | ColumnairFMModSmokeDetector | read-only | mandatory | Indicates the presence of a smoke detector for each of the Modules in this System. A value of notApplicable indicates that this OID does not apply to this devi… |
| 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.13 | ColumnairFMModWaterDetector | read-only | mandatory | Indicates the presence of a water leak detector for each of the Modules in this System. A value of notApplicable indicates that this OID does not apply to this… |
| 1.3.6.1.4.1.318.1.1.13.1.5.4 | NodeairFMModCooling | |||
| 1.3.6.1.4.1.318.1.1.13.1.5.4.1 | ScalarairFMModCoolTableSize | read-only | mandatory | The number of entries in the airFMModCoolTable. |
| 1.3.6.1.4.1.318.1.1.13.1.5.4.2 | TableairFMModCoolTable | not-accessible | mandatory | Allows for getting information from each module in the system. |
| 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1 | RowairFMModCoolEntry | not-accessible | mandatory | The module to get information from. |
| 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.1 | ColumnairFMModCoolModuleIndex | read-only | mandatory | The index of the module. |
| 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.2 | ColumnairFMModComp1 | read-only | mandatory | The status of compressor 1 of the tandem compressor unit (on or off). A value of notApplicable indicates that this OID does not apply to this device due to its… |
| 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.3 | ColumnairFMModComp2 | read-only | mandatory | The status of compressor 2 of the tandem compressor unit (on or off). A value of notApplicable indicates that this OID does not apply to this device due to its… |
| 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.4 | ColumnairFMModSuctPresKPa | read-only | mandatory | The refrigerant pressure measured at the suction inlet of the compressor. Measured in kiloPascals. A value of -2147483648 indicates that this OID does not appl… |
| 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.5 | ColumnairFMModSuctPresPSI | read-only | mandatory | The refrigerant pressure measured at the suction inlet of the compressor. Measured in pounds per square inch. A value of -2147483648 indicates that this OID do… |
| 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.6 | ColumnairFMModDischPresKPa | read-only | mandatory | The refrigerant pressure measured at the discharge outlet of the compressor. Measured in kiloPascals. A value of -2147483648 indicates that this OID does not a… |
| 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.7 | ColumnairFMModDischPresPSI | read-only | mandatory | The refrigerant pressure measured at the discharge outlet of the compressor. Measured in pounds per square inch. A value of -2147483648 indicates that this OID… |
| 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.8 | ColumnairFMModCondFluidVlvPos | read-only | mandatory | The position of the condenser fluid valve. The valve regulates the flow of liquid coolant into the heat exchanger (condenser). 100% indicates the valve is comp… |
| 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.9 | ColumnairFMModCoilFluidVlvPos | read-only | mandatory | The position of the coil fluid valve. The valve regulates the flow of liquid coolant in the fluid cooling coil (MultiCool, Economizer, or Chilled Water). 100% … |
| 1.3.6.1.4.1.318.1.1.13.1.5.5 | NodeairFMModHumidity | |||
| 1.3.6.1.4.1.318.1.1.13.1.5.5.1 | ScalarairFMModHumTableSize | read-only | mandatory | The number of entries in the airFMModHumTable. |
| 1.3.6.1.4.1.318.1.1.13.1.5.5.2 | TableairFMModHumTable | not-accessible | mandatory | Allows for getting information from each module in the system. |
| 1.3.6.1.4.1.318.1.1.13.1.5.5.2.1 | RowairFMModHumEntry | not-accessible | mandatory | The module to get information from. |
| 1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.1 | ColumnairFMModHumModuleIndex | read-only | mandatory | The index of the module. |
| 1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.2 | ColumnairFMModHumidifier | read-only | mandatory | The type of equipment installed in the Module to run the humidification mode. A value of notApplicable indicates that this OID does not apply to this device du… |
| 1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.3 | ColumnairFMModElectrodeCurrent | read-only | mandatory | The current drawn by the electrodes of the steam cylinder humidifier. Measured in tenths of amps. A value of -2147483648 indicates that this OID does not apply… |
| 1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.4 | ColumnairFMModHumActualOutput | read-only | mandatory | The humidification output of an individual Module. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its… |
| 1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.5 | ColumnairFMModWaterConductivity | read-only | mandatory | The conductivity of the water in the humidifier cylinder. Measured in microSiemens per centimeter. A value of -2147483648 indicates that this OID does not appl… |
| 1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.6 | ColumnairFMModHotWaterVlvPos | read-only | mandatory | The position of the hot water valve. 100% indicates the valve is completely open, and 0% indicates that the valve is closed. Measured in percent. A value of -2… |
| 1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.7 | ColumnairFMModStmElectHumMode | read-write | mandatory | Set the humidifier function mode. Off: Remove power from electrodes. Auto: Humidifier controlled by Module controller. Drain: Remove power from electrodes and … |
| 1.3.6.1.4.1.318.1.1.13.1.5.6 | NodeairFMModBlower1 | |||
| 1.3.6.1.4.1.318.1.1.13.1.5.6.1 | ScalarairFMModBlwr1TableSize | read-only | mandatory | The number of entries in the airFMModBlwr1Table. |
| 1.3.6.1.4.1.318.1.1.13.1.5.6.2 | TableairFMModBlwr1Table | not-accessible | mandatory | Allows for getting information from each module in the system. |
| 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1 | RowairFMModBlwr1Entry | not-accessible | mandatory | The module to get information from. |
| 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.1 | ColumnairFMModBlwr1ModuleIndex | read-only | mandatory | The index of the module. |
| 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.2 | ColumnairFMModBlwr1CtrlType | read-only | mandatory | The type of blower controller. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.3 | ColumnairFMModBlwr1CmdFreq | read-only | mandatory | The requested operating frequency for the blower. Measured in tenths of hertz. A value of -2147483648 indicates that this OID does not apply to this device due… |
| 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.4 | ColumnairFMModBlwr1ActFreq | read-only | mandatory | The frequency at which the blower controller is operating. Measured in tenths of hertz. A value of -2147483648 indicates that this OID does not apply to this d… |
| 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.5 | ColumnairFMModBlwr1Poles | read-only | mandatory | The number of poles of the blower motor that the blower controller is controlling. A value of -2147483648 indicates that this OID does not apply to this device… |
| 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.6 | ColumnairFMModBlwr1RatedHorsePower | read-only | mandatory | The power rating of the blower motor. Measured in hundredths of horsepower. A value of -2147483648 indicates that this OID does not apply to this device due to… |
| 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.7 | ColumnairFMModBlwr1RatedCurrent | read-only | mandatory | The current rating of the blower motor. Measured in hundredths of amps. A value of -2147483648 indicates that this OID does not apply to this device due to its… |
| 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.8 | ColumnairFMModBlwr1ActTorq | read-only | mandatory | The actual torque of the blower motor. Measured in hundredths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to i… |
| 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.9 | ColumnairFMModBlwr1Current | read-only | mandatory | The percent of rated current drawn by the blower motor. Measured in hundredths of percent. A value of -2147483648 indicates that this OID does not apply to thi… |
| 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.10 | ColumnairFMModBlwr1Vlt | read-only | mandatory | The voltage supplied to the blower motor. Measured in tenths of volts RMS. A value of -2147483648 indicates that this OID does not apply to this device due to … |
| 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.11 | ColumnairFMModBlwr1DCLinkVlt | read-only | mandatory | The voltage of the blower controller's DC bus. Measured in volts DC. A value of -2147483648 indicates that this OID does not apply to this device due to its co… |
| 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.12 | ColumnairFMModBlwr1AccTime | read-only | mandatory | The time to accelerate the blower to the specified frequency. Measured in tenths of seconds. A value of -2147483648 indicates that this OID does not apply to t… |
| 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.13 | ColumnairFMModBlwr1DecTime | read-only | mandatory | The time to decelerate the blower frequency to zero. Measured in tenths of seconds. A value of -2147483648 indicates that this OID does not apply to this devic… |
| 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.14 | ColumnairFMModBlwr1CapLife | read-only | mandatory | The remaining life of the main circuit capacitor. Measured in tenths of percent. A value of -2147483648 indicates that this OID does not apply to this device d… |
| 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.15 | ColumnairFMModBlwr1CtrlCoolFanLife | read-only | mandatory | The total operation time of the blower controller cooling fan. Measured in hours. A value of -2147483648 indicates that this OID does not apply to this device … |
| 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.16 | ColumnairFMModBlwr1ElOvMode | read-only | mandatory | Enables or disables the electronic overload relay. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.17 | ColumnairFMModBlwr1ElOvSetting | read-only | mandatory | The electronic overload relay is activated when the current exceeds this threshold. Measured in hundredths of amps. A value of -2147483648 indicates that this … |
| 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.18 | ColumnairFMModBlwr1ElOvTimeConst | read-only | mandatory | The delay between the current exceeding the overload threshold and the activation of the electronic overload relay. Measured in tenths of minutes. A value of -… |
| 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.19 | ColumnairFMModBlwr1FanPower | read-only | mandatory | The actual power of the blower motor. Measured in tenths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its co… |
| 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.20 | ColumnairFMModBlwr1HeatsinkTempC | read-only | mandatory | The temperature of the heatsink on the blower controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this de… |
| 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.21 | ColumnairFMModBlwr1HeatsinkTempF | read-only | mandatory | The temperature of the heatsink on the blower controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this… |
| 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.22 | ColumnairFMModBlwr1ChokeTempC | read-only | mandatory | The temperature of the choke on the blower controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this devic… |
| 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.23 | ColumnairFMModBlwr1ChokeTempF | read-only | mandatory | The temperature of the choke on the blower controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this de… |
| 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.24 | ColumnairFMModBlwr1InverterTempC | read-only | mandatory | The temperature of the inverter on the blower controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this de… |
| 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.25 | ColumnairFMModBlwr1InverterTempF | read-only | mandatory | The temperature of the inverter on the blower controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this… |
| 1.3.6.1.4.1.318.1.1.13.1.5.7 | NodeairFMModBlower2 | |||
| 1.3.6.1.4.1.318.1.1.13.1.5.7.1 | ScalarairFMModBlwr2TableSize | read-only | mandatory | The number of entries in the airFMModBlwr2Table. |
| 1.3.6.1.4.1.318.1.1.13.1.5.7.2 | TableairFMModBlwr2Table | not-accessible | mandatory | Allows for getting information from each module in the system. |
| 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1 | RowairFMModBlwr2Entry | not-accessible | mandatory | The module to get information from. |
| 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.1 | ColumnairFMModBlwr2ModuleIndex | read-only | mandatory | The index of the module. |
| 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.2 | ColumnairFMModBlwr2CtrlType | read-only | mandatory | The type of blower controller. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.3 | ColumnairFMModBlwr2CmdFreq | read-only | mandatory | The requested operating frequency for the blower. Measured in tenths of hertz. A value of -2147483648 indicates that this OID does not apply to this device due… |
| 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.4 | ColumnairFMModBlwr2ActFreq | read-only | mandatory | The frequency at which the blower controller is operating. Measured in tenths of hertz. A value of -2147483648 indicates that this OID does not apply to this d… |
| 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.5 | ColumnairFMModBlwr2Poles | read-only | mandatory | The number of poles of the blower motor that the blower controller is controlling. A value of -2147483648 indicates that this OID does not apply to this device… |
| 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.6 | ColumnairFMModBlwr2RatedHorsePower | read-only | mandatory | The power rating of the blower motor. Measured in hundredths of horsepower. A value of -2147483648 indicates that this OID does not apply to this device due to… |
| 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.7 | ColumnairFMModBlwr2RatedCurrent | read-only | mandatory | The current rating of the blower motor. Measured in hundredths of amps. A value of -2147483648 indicates that this OID does not apply to this device due to its… |
| 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.8 | ColumnairFMModBlwr2ActTorq | read-only | mandatory | The actual torque of the blower motor. Measured in hundredths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to i… |
| 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.9 | ColumnairFMModBlwr2Current | read-only | mandatory | The percent of rated current drawn by the blower motor. Measured in hundredths of percent. A value of -2147483648 indicates that this OID does not apply to thi… |
| 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.10 | ColumnairFMModBlwr2Vlt | read-only | mandatory | The voltage supplied to the blower motor. Measured in tenths of volts RMS. A value of -2147483648 indicates that this OID does not apply to this device due to … |
| 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.11 | ColumnairFMModBlwr2DCLinkVlt | read-only | mandatory | The voltage of the blower controller's DC bus. Measured in volts DC. A value of -2147483648 indicates that this OID does not apply to this device due to its co… |
| 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.12 | ColumnairFMModBlwr2AccTime | read-only | mandatory | The time to accelerate the blower to the specified frequency. Measured in tenths of seconds. A value of -2147483648 indicates that this OID does not apply to t… |
| 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.13 | ColumnairFMModBlwr2DecTime | read-only | mandatory | The time to decelerate the blower frequency to zero. Measured in tenths of seconds. A value of -2147483648 indicates that this OID does not apply to this devic… |
| 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.14 | ColumnairFMModBlwr2CapLife | read-only | mandatory | The remaining life of the main circuit capacitor. Measured in tenths of percent. A value of -2147483648 indicates that this OID does not apply to this device d… |
| 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.15 | ColumnairFMModBlwr2CtrlCoolFanLife | read-only | mandatory | The total operation time of the blower controller cooling fan. Measured in hours. A value of -2147483648 indicates that this OID does not apply to this device … |
| 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.16 | ColumnairFMModBlwr2ElOvMode | read-only | mandatory | Enables or disables the electronic overload relay. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.17 | ColumnairFMModBlwr2ElOvSetting | read-only | mandatory | The electronic overload relay is activated when the current exceeds this threshold. Measured in hundredths of amps. A value of -2147483648 indicates that this … |
| 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.18 | ColumnairFMModBlwr2ElOvTimeConst | read-only | mandatory | The delay between the current exceeding the overload threshold and the activation of the electronic overload relay. Measured in tenths of minutes. A value of -… |
| 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.19 | ColumnairFMModBlwr2FanPower | read-only | mandatory | The actual power of the blower motor. Measured in tenths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its co… |
| 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.20 | ColumnairFMModBlwr2HeatsinkTempC | read-only | mandatory | The temperature of the heatsink on the blower controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this de… |
| 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.21 | ColumnairFMModBlwr2HeatsinkTempF | read-only | mandatory | The temperature of the heatsink on the blower controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this… |
| 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.22 | ColumnairFMModBlwr2ChokeTempC | read-only | mandatory | The temperature of the choke on the blower controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this devic… |
| 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.23 | ColumnairFMModBlwr2ChokeTempF | read-only | mandatory | The temperature of the choke on the blower controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this de… |
| 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.24 | ColumnairFMModBlwr2InverterTempC | read-only | mandatory | The temperature of the inverter on the blower controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this de… |
| 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.25 | ColumnairFMModBlwr2InverterTempF | read-only | mandatory | The temperature of the inverter on the blower controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this… |
| 1.3.6.1.4.1.318.1.1.13.1.5.8 | NodeairFMModRunHours | |||
| 1.3.6.1.4.1.318.1.1.13.1.5.8.1 | ScalarairFMModRHTableSize | read-only | mandatory | The number of entries in the airFMModRHTable. |
| 1.3.6.1.4.1.318.1.1.13.1.5.8.2 | TableairFMModRHTable | not-accessible | mandatory | Allows for getting information from each module in the system. |
| 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1 | RowairFMModRHEntry | not-accessible | mandatory | The module to get information from. |
| 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.1 | ColumnairFMModRHModuleIndex | read-only | mandatory | The index of the module. |
| 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.2 | ColumnairFMModRHComp1 | read-only | mandatory | Compressor 1 run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.3 | ColumnairFMModRHComp2 | read-only | mandatory | Compressor 2 run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.4 | ColumnairFMModRHHeater | read-only | mandatory | Heater run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.5 | ColumnairFMModRHHum | read-only | mandatory | Humidifier run hours A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.6 | ColumnairFMModRHBlwr1 | read-only | mandatory | Blower 1 run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.7 | ColumnairFMModRHBlwr2 | read-only | mandatory | Blower 2 run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.8 | ColumnairFMModRHBlwrCtrl1 | read-only | mandatory | Blower Controller 1 run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.9 | ColumnairFMModRHBlwrCtrl2 | read-only | mandatory | Blower Controller 2 run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
| 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.10 | ColumnairFMModRHComp1Reset | read-write | mandatory | Reset the compressor 1 run hours. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not … |
| 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.11 | ColumnairFMModRHComp2Reset | read-write | mandatory | Reset the compressor 2 run hours. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not … |
| 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.12 | ColumnairFMModRHHeaterReset | read-write | mandatory | Reset the heater run hours. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply … |
| 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.13 | ColumnairFMModRHHumReset | read-write | mandatory | Reset the humidifier run hours. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not ap… |
| 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.14 | ColumnairFMModRHBlwr1Reset | read-write | mandatory | Reset the blower 1 run hours. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not appl… |
| 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.15 | ColumnairFMModRHBlwr2Reset | read-write | mandatory | Reset the blower 2 run hours. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not appl… |
| 1.3.6.1.4.1.318.1.1.13.1.5.9 | NodeairFMModServIntervals | |||
| 1.3.6.1.4.1.318.1.1.13.1.5.9.1 | ScalarairFMModServIntComp1 | read-write | mandatory | The interval at which to generate a maintenance alarm for compressor 1. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OI… |
| 1.3.6.1.4.1.318.1.1.13.1.5.9.2 | ScalarairFMModServIntComp2 | read-write | mandatory | The interval at which to generate a maintenance alarm for compressor 2. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OI… |
| 1.3.6.1.4.1.318.1.1.13.1.5.9.3 | ScalarairFMModServIntHeater | read-write | mandatory | The interval at which to generate a maintenance alarm for the reheat components. Values stored in increments of 100 hours. A value of -2147483648 indicates tha… |
| 1.3.6.1.4.1.318.1.1.13.1.5.9.4 | ScalarairFMModServIntHum | read-write | mandatory | The interval at which to generate a maintenance alarm for the humidifier. Values stored in increments of 100 hours. A value of -2147483648 indicates that this … |
| 1.3.6.1.4.1.318.1.1.13.1.5.9.5 | ScalarairFMModServIntBlwr1 | read-write | mandatory | The interval at which to generate a maintenance alarm for blower 1. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OID do… |
| 1.3.6.1.4.1.318.1.1.13.1.5.9.6 | ScalarairFMModServIntBlwr2 | read-write | mandatory | The interval at which to generate a maintenance alarm for blower 2. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OID do… |
| 1.3.6.1.4.1.318.1.1.13.1.5.9.7 | ScalarairFMModServIntBlwrCtrl1 | read-write | mandatory | The interval at which to generate a maintenance alarm for blower controller 1. Values stored in increments of 100 hours. A value of -2147483648 indicates that … |
| 1.3.6.1.4.1.318.1.1.13.1.5.9.8 | ScalarairFMModServIntBlwrCtrl2 | read-write | mandatory | The interval at which to generate a maintenance alarm for blower controller 2. Values stored in increments of 100 hours. A value of -2147483648 indicates that … |
| 1.3.6.1.4.1.318.1.1.13.1.5.10 | NodeairFMModServIntResets | |||
| 1.3.6.1.4.1.318.1.1.13.1.5.10.1 | ScalarairFMModServIntResetTableSize | read-only | mandatory | The number of entries in the airFMModServIntTable. |
| 1.3.6.1.4.1.318.1.1.13.1.5.10.2 | TableairFMModServIntResetTable | not-accessible | mandatory | Allows for getting information from each module in the system. |
| 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1 | RowairFMModServIntResetEntry | not-accessible | mandatory | The module to get information from. |
| 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.1 | ColumnairFMModServIntResetModuleIndex | read-only | mandatory | The index of the module. |
| 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.2 | ColumnairFMModServIntComp1Reset | read-write | mandatory | Reset the compressor 1 service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicate… |
| 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.3 | ColumnairFMModServIntComp2Reset | read-write | mandatory | Reset the compressor 2 service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicate… |
| 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.4 | ColumnairFMModServIntHeaterReset | read-write | mandatory | Reset the heater service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that… |
| 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.5 | ColumnairFMModServIntHumReset | read-write | mandatory | Reset the humidifier service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates … |
| 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.6 | ColumnairFMModServIntBlwr1Reset | read-write | mandatory | Reset the blower 1 service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates th… |
| 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.7 | ColumnairFMModServIntBlwr2Reset | read-write | mandatory | Reset the blower 2 service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates th… |
| 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.8 | ColumnairFMModServIntBlwrCtrl1Reset | read-write | mandatory | Reset the blower controller 1 service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable i… |
| 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.9 | ColumnairFMModServIntBlwrCtrl2Reset | read-write | mandatory | Reset the blower controller 2 service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable i… |
| 1.3.6.1.4.1.318.1.1.13.1.6 | NodeairFMAlarms | |||
| 1.3.6.1.4.1.318.1.1.13.1.6.1 | ScalarairFMAlarmClearActiveGroupAlarms | read-write | mandatory | Clear active group alarms. If alarm conditions are still present, new alarms will be generated for those conditions. Getting this OID will do nothing and retur… |
| 1.3.6.1.4.1.318.1.1.13.1.6.2 | ScalarairFMAlarmClearActiveSysModAlarms | read-write | mandatory | Clear active system and module alarms. If alarm conditions are still present, new alarms will be generated for those conditions. Getting this OID will do nothi… |
| 1.3.6.1.4.1.318.1.1.13.1.6.3 | ScalarairFMAlarmConditionsTableSize | read-only | mandatory | The number of active alarm conditions in the airFMAlarmConditionTable. |
| 1.3.6.1.4.1.318.1.1.13.1.6.4 | TableairFMAlarmConditionsTable | not-accessible | mandatory | Table of active alarm conditions for the device. |
| 1.3.6.1.4.1.318.1.1.13.1.6.4.1 | RowairFMAlarmConditionsEntry | not-accessible | mandatory | Alarm condition specification |
| 1.3.6.1.4.1.318.1.1.13.1.6.4.1.1 | ColumnairFMAlarmConditionsIndex | read-only | mandatory | Alarm condition index. |
| 1.3.6.1.4.1.318.1.1.13.1.6.4.1.2 | ColumnairFMAlarmSeverity | read-only | mandatory | Severity of the alarm. |
| 1.3.6.1.4.1.318.1.1.13.1.6.4.1.3 | ColumnairFMAlarmType | read-only | mandatory | Type of alarm. |
| 1.3.6.1.4.1.318.1.1.13.1.6.4.1.4 | ColumnairFMEventCode | read-only | mandatory | APC event code for the alarm. |
| 1.3.6.1.4.1.318.1.1.13.1.6.4.1.5 | ColumnairFMAlarmDate | read-only | mandatory | Date the alarm was recorded. |
| 1.3.6.1.4.1.318.1.1.13.1.6.4.1.6 | ColumnairFMAlarmTime | read-only | mandatory | Time the alarm was recorded. |
| 1.3.6.1.4.1.318.1.1.13.1.6.4.1.7 | ColumnairFMAlarmDescription | read-only | mandatory | Description of the alarm. |
| 1.3.6.1.4.1.318.1.1.13.2 | NodeairPA | |||
| 1.3.6.1.4.1.318.1.1.13.2.1 | NodeairPAIdent | |||
| 1.3.6.1.4.1.318.1.1.13.2.1.1 | ScalarairPAIdentName | read-only | mandatory | A character string identifying the device name. |
| 1.3.6.1.4.1.318.1.1.13.2.1.2 | ScalarairPAModelNumber | read-only | mandatory | A character string identifying the device model number. |
| 1.3.6.1.4.1.318.1.1.13.2.1.3 | ScalarairPADateOfManufacture | read-only | mandatory | A character string identifying when the device was produced. |
| 1.3.6.1.4.1.318.1.1.13.2.1.4 | ScalarairPASerialNumber | read-only | mandatory | A character string identifying the device serial number. |
| 1.3.6.1.4.1.318.1.1.13.2.1.5 | ScalarairPAFirmwareRevision | read-only | mandatory | A character string identifying the device firmware revision. |
| 1.3.6.1.4.1.318.1.1.13.2.1.6 | ScalarairPAHardwareRevision | read-only | mandatory | A character string identifying the device hardware revision. |
| 1.3.6.1.4.1.318.1.1.13.2.2 | NodeairPAStatus | |||
| 1.3.6.1.4.1.318.1.1.13.2.2.1 | ScalarairPASystemPower | read-only | mandatory | The status of the unit's system power setting. ON(1) The system power is turned on. OFF(2) The system power is turned off. |
| 1.3.6.1.4.1.318.1.1.13.2.2.2 | ScalarairPAOperatingMode | read-only | mandatory | The current operating mode of the unit. OFF(1) The system is off. VENTING(2) The system's venting function is active. COOLING(3) The system's cooling function … |
| 1.3.6.1.4.1.318.1.1.13.2.2.3 | ScalarairPASetpointTempF | read-only | mandatory | The temperature setpoint in Fahrenheit to which the unit is controlling. |
| 1.3.6.1.4.1.318.1.1.13.2.2.4 | ScalarairPASetpointTempC | read-only | mandatory | The temperature setpoint in Celsius to which the unity is controlling. |
| 1.3.6.1.4.1.318.1.1.13.2.2.5 | ScalarairPABlowerSpeed | read-only | mandatory | The unit's blower speed setting. LOW(1) The blower speed is low. HIGH(2) The blower speed is high. |
| 1.3.6.1.4.1.318.1.1.13.2.2.6 | ScalarairPACompressor | read-only | mandatory | The unit's compressor status. ON(1) The compressor is turned on. OFF(2) The compressor is turned off. |
| 1.3.6.1.4.1.318.1.1.13.2.2.7 | ScalarairPACondenserFan | read-only | mandatory | The unit's condenser fan status. ON(1) The condenser fan is turned on. OFF(2) The condenser fan is turned off. |
| 1.3.6.1.4.1.318.1.1.13.2.2.8 | ScalarairPACondensatePump | read-only | mandatory | The unit's condensate pump status. ON(1) The condensate pump is turned on. OFF(2) The condensate pump is turned off. |
| 1.3.6.1.4.1.318.1.1.13.2.2.9 | ScalarairPASupplyTempF | read-only | mandatory | The supply temperature in degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.2.2.10 | ScalarairPASupplyTempC | read-only | mandatory | The supply temperature in degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.2.2.11 | ScalarairPAReturnTempF | read-only | mandatory | The return temperature in degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.2.2.12 | ScalarairPAReturnTempC | read-only | mandatory | The return temperature in degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.2.2.13 | ScalarairPARemoteTempF | read-only | mandatory | The remote temperature in degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.2.2.14 | ScalarairPARemoteTempC | read-only | mandatory | The remote temperature in degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.2.2.15 | ScalarairPARemoteHumidity | read-only | mandatory | The remote humidity. |
| 1.3.6.1.4.1.318.1.1.13.3 | NodeairIR | |||
| 1.3.6.1.4.1.318.1.1.13.3.1 | NodeairIRAlarms | |||
| 1.3.6.1.4.1.318.1.1.13.3.1.1 | ScalarairIRAlarmConditionsTableSize | read-only | mandatory | The number of active alarm conditions in the airIRAlarmConditionTable. |
| 1.3.6.1.4.1.318.1.1.13.3.1.2 | TableairIRAlarmConditionsTable | not-accessible | mandatory | Table of active alarm conditions for the device. |
| 1.3.6.1.4.1.318.1.1.13.3.1.2.1 | RowairIRAlarmConditionsEntry | not-accessible | mandatory | Alarm condition specification |
| 1.3.6.1.4.1.318.1.1.13.3.1.2.1.1 | ColumnairIRAlarmConditionsIndex | read-only | mandatory | Alarm condition index. |
| 1.3.6.1.4.1.318.1.1.13.3.1.2.1.2 | ColumnairIREventCode | read-only | mandatory | Code for the alarm. |
| 1.3.6.1.4.1.318.1.1.13.3.1.2.1.3 | ColumnairIRAlarmDescription | read-only | mandatory | Description of the alarm. |
| 1.3.6.1.4.1.318.1.1.13.3.2 | NodeairIRRC | |||
| 1.3.6.1.4.1.318.1.1.13.3.2.1 | NodeairIRRCGroup | |||
| 1.3.6.1.4.1.318.1.1.13.3.2.1.1 | NodeairIRRCGroupStatus | |||
| 1.3.6.1.4.1.318.1.1.13.3.2.1.1.1 | ScalarairIRRCGroupStatusCoolOutput | read-only | mandatory | Group coolant output in tenths of kW. |
| 1.3.6.1.4.1.318.1.1.13.3.2.1.1.2 | ScalarairIRRCGroupStatusCoolDemand | read-only | mandatory | Group coolant demand in tenths of kW. |
| 1.3.6.1.4.1.318.1.1.13.3.2.1.1.3 | ScalarairIRRCGroupStatusAirFlowUS | read-only | mandatory | Group air flow in cubic feet per minute. |
| 1.3.6.1.4.1.318.1.1.13.3.2.1.1.4 | ScalarairIRRCGroupStatusAirFlowMetric | read-only | mandatory | Group air flow in liters per second. |
| 1.3.6.1.4.1.318.1.1.13.3.2.1.1.5 | ScalarairIRRCGroupStatusMaxRackInletTempUS | read-only | mandatory | Group maximum rack inlet temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.2.1.1.6 | ScalarairIRRCGroupStatusMaxRackInletTempMetric | read-only | mandatory | Group maximum rack inlet temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.2.1.1.7 | ScalarairIRRCGroupStatusMinRackInletTempUS | read-only | mandatory | Group minimum rack inlet temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.2.1.1.8 | ScalarairIRRCGroupStatusMinRackInletTempMetric | read-only | mandatory | Group minimum rack inlet temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.2.1.1.9 | ScalarairIRRCGroupStatusActiveFlowControlStatus | read-only | mandatory | Status of the active flow control system. |
| 1.3.6.1.4.1.318.1.1.13.3.2.1.2 | NodeairIRRCGroupSetpoints | |||
| 1.3.6.1.4.1.318.1.1.13.3.2.1.2.1 | ScalarairIRRCGroupSetpointsCoolUS | read-write | mandatory | Group cooling setpoint in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.2.1.2.2 | ScalarairIRRCGroupSetpointsCoolMetric | read-write | mandatory | Group cooling setpoint in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.2.1.2.3 | ScalarairIRRCGroupSetpointsSupplyAirUS | read-write | mandatory | Group supply air setpoint in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.2.1.2.4 | ScalarairIRRCGroupSetpointsSupplyAirMetric | read-write | mandatory | Group supply air setpoint in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.2.1.2.5 | ScalarairIRRCGroupSetpointsFanSpeedPreference | read-write | mandatory | The preferred fan speed setting. |
| 1.3.6.1.4.1.318.1.1.13.3.2.1.2.6 | ScalarairIRRCGroupSetpointsFanSpeedControl | read-write | mandatory | The fan speed control setting. Automatic(1) - controller manages fan speed. Manual(2) - fan speed is fixed and set by the fan speed preference. See airIRRCGrou… |
| 1.3.6.1.4.1.318.1.1.13.3.2.1.2.7 | ScalarairIRRCGroupSetpointsActiveFlowControlBias | read-write | mandatory | The active flow control bias setting. |
| 1.3.6.1.4.1.318.1.1.13.3.2.1.3 | NodeairIRRCGroupConfig | |||
| 1.3.6.1.4.1.318.1.1.13.3.2.1.3.1 | ScalarairIRRCGroupConfigNumberofCoolingUnits | read-write | mandatory | The number of cooling units present in the group. |
| 1.3.6.1.4.1.318.1.1.13.3.2.1.3.2 | ScalarairIRRCGroupConfigConfigurationType | read-write | mandatory | The group configuration type. |
| 1.3.6.1.4.1.318.1.1.13.3.2.1.3.3 | ScalarairIRRCGroupConfigPctGlycol | read-write | mandatory | The glycol mixture in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.2.1.3.4 | ScalarairIRRCGroupConfigCoolGainP | read-write | mandatory | The gain component of the PID in hundredths. |
| 1.3.6.1.4.1.318.1.1.13.3.2.1.3.5 | ScalarairIRRCGroupConfigCoolResetRateI | read-write | mandatory | The integral component of the PID in hundredths. |
| 1.3.6.1.4.1.318.1.1.13.3.2.1.3.6 | ScalarairIRRCGroupConfigCoolDerivativeD | read-write | mandatory | The derivative component of the PID in hundredths. |
| 1.3.6.1.4.1.318.1.1.13.3.2.1.3.7 | ScalarairIRRCGroupConfigMaxFanSpeed | read-write | mandatory | The maximum desired fan speed setting in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.2.1.3.8 | ScalarairIRRCGroupConfigNumberOfActiveFlowControllers | read-write | mandatory | The number of active flow controllers present in the group. |
| 1.3.6.1.4.1.318.1.1.13.3.2.1.3.9 | ScalarairIRRCGroupConfigActiveFlowControllerLampTest | read-write | mandatory | Turns off/on the active flow controller lamp test. |
| 1.3.6.1.4.1.318.1.1.13.3.2.1.3.10 | ScalarairIRRCGroupConfigAltitudeUS | read-write | mandatory | The group altitude of the units above sea level in feet. |
| 1.3.6.1.4.1.318.1.1.13.3.2.1.3.11 | ScalarairIRRCGroupConfigAltitudeMetric | read-write | mandatory | The group altitude of the units above sea level in meters. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2 | NodeairIRRCUnit | |||
| 1.3.6.1.4.1.318.1.1.13.3.2.2.1 | NodeairIRRCUnitIdent | |||
| 1.3.6.1.4.1.318.1.1.13.3.2.2.1.1 | ScalarairIRRCUnitIdentID | read-write | mandatory | The unit identification number. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.1.2 | ScalarairIRRCUnitIdentName | read-write | mandatory | A character string identifying the unit name. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.1.3 | ScalarairIRRCUnitIdentLocation | read-write | mandatory | A character string identifying the unit location. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.1.4 | ScalarairIRRCUnitIdentModelNumber | read-only | mandatory | A character string identifying the unit model number. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.1.5 | ScalarairIRRCUnitIdentSerialNumber | read-only | mandatory | A character string identifying the unit serial number. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.1.6 | ScalarairIRRCUnitIdentFirmwareRevision | read-only | mandatory | A character string identifying the unit firmware version. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.1.7 | ScalarairIRRCUnitIdentHardwareRevision | read-only | mandatory | A character string identifying the unit controller hardware revision. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.1.8 | ScalarairIRRCUnitIdentManufactureDate | read-only | mandatory | A character string identifying the unit manufacture date. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2 | NodeairIRRCUnitStatus | |||
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2.1 | ScalarairIRRCUnitStatusOperateMode | read-only | mandatory | The cooling unit operating mode. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2.2 | ScalarairIRRCUnitStatusCoolOutput | read-only | mandatory | The unit cooling output in tenths of kW. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2.3 | ScalarairIRRCUnitStatusCoolDemand | read-only | mandatory | The unit cooling demand in tenths of kW. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2.4 | ScalarairIRRCUnitStatusAirFlowUS | read-only | mandatory | The unit air flow in cubic feet per minute. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2.5 | ScalarairIRRCUnitStatusAirFlowMetric | read-only | mandatory | The unit air flow in hundredths of liters per second. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2.6 | ScalarairIRRCUnitStatusRackInletTempUS | read-only | mandatory | The unit rack inlet temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2.7 | ScalarairIRRCUnitStatusRackInletTempMetric | read-only | mandatory | The unit rack inlet temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2.8 | ScalarairIRRCUnitStatusSupplyAirTempUS | read-only | mandatory | The unit supply air temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2.9 | ScalarairIRRCUnitStatusSupplyAirTempMetric | read-only | mandatory | The unit supply air temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2.10 | ScalarairIRRCUnitStatusReturnAirTempUS | read-only | mandatory | The unit return air temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2.11 | ScalarairIRRCUnitStatusReturnAirTempMetric | read-only | mandatory | The unit return air temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2.12 | ScalarairIRRCUnitStatusContainmtDPUS | read-only | mandatory | The unit containment differential pressure in hundredths of inches of water. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2.13 | ScalarairIRRCUnitStatusContainmtDPMetric | read-only | mandatory | The unit containment differential pressure in Pa. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2.14 | ScalarairIRRCUnitStatusFilterDPUS | read-only | mandatory | The unit air filter differential pressure in hundredths of inches of water. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2.15 | ScalarairIRRCUnitStatusFilterDPMetric | read-only | mandatory | The unit air filter differential pressure in Pa. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2.16 | ScalarairIRRCUnitStatusFanSpeed | read-only | mandatory | The unit average fan speed in tenths of percent. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2.17 | ScalarairIRRCUnitStatusInputState | read-only | mandatory | The state of the input contact. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2.18 | ScalarairIRRCUnitStatusOutputState | read-only | mandatory | The state of the output relay. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2.19 | ScalarairIRRCUnitStatusActivePowerSource | read-only | mandatory | The power source that is powering the unit. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2.20 | ScalarairIRRCUnitStatusFluidValvePosition | read-only | mandatory | The fluid valve position in percent open. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2.21 | ScalarairIRRCUnitStatusFluidFlowUS | read-only | mandatory | The fluid flow in tenths of gallons per minute. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2.22 | ScalarairIRRCUnitStatusFluidFlowMetric | read-only | mandatory | The fluid flow in hundredths of liters per second. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2.23 | ScalarairIRRCUnitStatusEnteringFluidTemperatureUS | read-only | mandatory | The temperature of the entering fluid in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2.24 | ScalarairIRRCUnitStatusEnteringFluidTemperatureMetric | read-only | mandatory | The temperature of the entering fluid in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2.25 | ScalarairIRRCUnitStatusLeavingFluidTemperatureUS | read-only | mandatory | The temperature of the Leaving fluid in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2.26 | ScalarairIRRCUnitStatusLeavingFluidTemperatureMetric | read-only | mandatory | The temperature of the Leaving fluid in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.2.27 | ScalarairIRRCUnitStatusLeakSensor | read-only | mandatory | The state (no-leak/leak) of the leak sensor. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.3 | NodeairIRRCUnitRunHours | |||
| 1.3.6.1.4.1.318.1.1.13.3.2.2.3.1 | ScalarairIRRCUnitRunHoursAirFilter | read-only | mandatory | Unit air filter run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.3.2 | ScalarairIRRCUnitRunHoursFan1 | read-only | mandatory | Unit fan 1 run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.3.3 | ScalarairIRRCUnitRunHoursFan2 | read-only | mandatory | Unit fan 2 run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.3.4 | ScalarairIRRCUnitRunHoursFan3 | read-only | mandatory | Unit fan 3 run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.3.5 | ScalarairIRRCUnitRunHoursFan4 | read-only | mandatory | Unit fan 4 run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.3.6 | ScalarairIRRCUnitRunHoursFan5 | read-only | mandatory | Unit fan 5 run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.3.7 | ScalarairIRRCUnitRunHoursFan6 | read-only | mandatory | Unit fan 6 run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.3.8 | ScalarairIRRCUnitRunHoursFan7 | read-only | mandatory | Unit fan 7 run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.3.9 | ScalarairIRRCUnitRunHoursFan8 | read-only | mandatory | Unit fan 8 run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.3.10 | ScalarairIRRCUnitRunHoursFanPowerSupplyLeft | read-only | mandatory | Unit fan left power supply run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.3.11 | ScalarairIRRCUnitRunHoursFanPowerSupplyRight | read-only | mandatory | Unit fan right power supply run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.3.12 | ScalarairIRRCUnitRunHoursCondensatePump | read-only | mandatory | Unit condensate pump run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.3.13 | ScalarairIRRCUnitRunHoursFanPowerSupplyFeedALeft | read-only | mandatory | Unit fan, DC power feed A, left power supply run hours. This is only valid for a DC input unit. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.3.14 | ScalarairIRRCUnitRunHoursFanPowerSupplyFeedARight | read-only | mandatory | Unit fan, DC power feed A, right power supply run hours. This is only valid for a DC input unit. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.3.15 | ScalarairIRRCUnitRunHoursFanPowerSupplyFeedBLeft | read-only | mandatory | Unit fan, DC power feed B, left power supply run hours. This is only valid for a DC input unit. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.3.16 | ScalarairIRRCUnitRunHoursFanPowerSupplyFeedBRight | read-only | mandatory | Unit fan, DC power feed B, right power supply run hours. This is only valid for a DC input unit. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.4 | NodeairIRRCUnitServiceIntervals | |||
| 1.3.6.1.4.1.318.1.1.13.3.2.2.4.1 | ScalarairIRRCUnitServiceIntervalsAirFilter | read-write | mandatory | Air filter service interval in weeks. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.4.2 | ScalarairIRRCUnitServiceIntervalsAirFilterAlarm | read-write | mandatory | The air filter service interval alarm enable/disable. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.5 | NodeairIRRCUnitThresholds | |||
| 1.3.6.1.4.1.318.1.1.13.3.2.2.5.1 | ScalarairIRRCUnitThresholdsRackInletHighTempUS | read-write | mandatory | Unit rack inlet air high temperature threshold in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.5.2 | ScalarairIRRCUnitThresholdsRackInletHighTempMetric | read-write | mandatory | Unit rack inlet air high temperature threshold in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.5.3 | ScalarairIRRCUnitThresholdsSupplyAirHighTempUS | read-write | mandatory | Unit supply air high temperature threshold in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.5.4 | ScalarairIRRCUnitThresholdsSupplyAirHighTempMetric | read-write | mandatory | Unit supply air high temperature threshold in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.5.5 | ScalarairIRRCUnitThresholdsReturnAirHighTempUS | read-write | mandatory | Unit return air high temperature threshold in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.5.6 | ScalarairIRRCUnitThresholdsReturnAirHighTempMetric | read-write | mandatory | Unit return air high temperature threshold in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.5.7 | ScalarairIRRCUnitThresholdsEnteringFluidHighTempUS | read-write | mandatory | Unit entering fluid high temperature threshold in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.5.8 | ScalarairIRRCUnitThresholdsEnteringFluidHighTempMetric | read-write | mandatory | Unit incoming fluid high temperature threshold in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.6 | NodeairIRRCUnitConfig | |||
| 1.3.6.1.4.1.318.1.1.13.3.2.2.6.1 | ScalarairIRRCUnitConfigCoolCapacity | read-write | mandatory | The cooling capacity options setting. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.6.2 | ScalarairIRRCUnitConfigStartupDelay | read-write | mandatory | The startup delay in seconds. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.6.3 | ScalarairIRRCUnitConfigIdleOnLeakDetect | read-write | mandatory | The idle on leak options setting. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.6.4 | ScalarairIRRCUnitConfigPowerSource | read-write | mandatory | The configured power source of the unit. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.6.5 | ScalarairIRRCUnitConfigInputNormalState | read-write | mandatory | The normal state of the input contact. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.6.6 | ScalarairIRRCUnitConfigOutputNormalState | read-write | mandatory | The normal state of the output relay. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.6.7 | ScalarairIRRCUnitConfigOutputSource | read-write | mandatory | The source of output relay change. |
| 1.3.6.1.4.1.318.1.1.13.3.2.2.6.8 | ScalarairIRRCUnitConfigIdleOnCoolFail | read-write | mandatory | The idle on cool fail options setting. If yes, the system will go into idle mode when a cooling failure is detected. If no, the system will not go into idle mo… |
| 1.3.6.1.4.1.318.1.1.13.3.3 | NodeairIRRP | |||
| 1.3.6.1.4.1.318.1.1.13.3.3.1 | NodeairIRRP100 | |||
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1 | NodeairIRRP100Group | |||
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1 | NodeairIRRP100GroupStatus | |||
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.1 | ScalarairIRRP100GroupStatusAirFlowUS | read-only | mandatory | Group air flow in cubic feet per minute. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.2 | ScalarairIRRP100GroupStatusAirFlowMetric | read-only | mandatory | Group air flow in liters per second. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.3 | ScalarairIRRP100GroupStatusMaxRackInletTempUS | read-only | mandatory | Group maximum rack inlet temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.4 | ScalarairIRRP100GroupStatusMaxRackInletTempMetric | read-only | mandatory | Group maximum rack inlet temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.5 | ScalarairIRRP100GroupStatusMinRackInletTempUS | read-only | mandatory | Group minimum rack inlet temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.6 | ScalarairIRRP100GroupStatusMinRackInletTempMetric | read-only | mandatory | Group minimum rack inlet temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.7 | ScalarairIRRP100GroupStatusCoolDemand | read-only | mandatory | Group coolant demand in tenths of kiloWatts. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.8 | ScalarairIRRP100GroupStatusCoolOutput | read-only | mandatory | Group coolant output in tenths of kiloWatts. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.9 | ScalarairIRRP100GroupStatusHumidifyDemand | read-only | mandatory | The amount of humidification the group is demanding from the humidifiers in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.10 | ScalarairIRRP100GroupStatusHumidifyOutput | read-only | mandatory | The actual amount of humidification the group is supplying in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.11 | ScalarairIRRP100GroupStatusDehumidifyDemand | read-only | mandatory | The amount of dehumidification the group is demanding from the electric heaters in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.12 | ScalarairIRRP100GroupStatusDehumidifyOutput | read-only | mandatory | The actual amount of dehumidification the group is supplying in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.13 | ScalarairIRRP100GroupStatusReheatDemand | read-only | mandatory | The amount of heating the group is demanding from the electric heaters in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.14 | ScalarairIRRP100GroupStatusReheatOutput | read-only | mandatory | The actual amount of heating the group is supplying in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.15 | ScalarairIRRP100GroupStatusActiveFlowControlStatus | read-only | mandatory | Status of the active flow control system. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.16 | ScalarairIRRP100GroupStatusDewPointTempUS | read-only | mandatory | Group average dew point temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.17 | ScalarairIRRP100GroupStatusDewPointTempMetric | read-only | mandatory | Group average dew point temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2 | NodeairIRRP100GroupSetpoints | |||
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.1 | ScalarairIRRP100GroupSetpointsCoolUS | read-write | mandatory | Group cooling setpoint in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.2 | ScalarairIRRP100GroupSetpointsCoolMetric | read-write | mandatory | Group cooling setpoint in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.3 | ScalarairIRRP100GroupSetpointsSupplyAirUS | read-write | mandatory | Group supply air setpoint in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.4 | ScalarairIRRP100GroupSetpointsSupplyAirMetric | read-write | mandatory | Group supply air setpoint in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.5 | ScalarairIRRP100GroupSetpointsHumidify | read-write | mandatory | Group humidify setpoint in tenths of percent relative humidity. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.6 | ScalarairIRRP100GroupSetpointsDehumidify | read-write | mandatory | Group dehumidify setpoint in tenths of percent relative humidity. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.7 | ScalarairIRRP100GroupSetpointsDehumidifyDeadband | read-write | mandatory | Group dehumidify deadband in percent relative humidity. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.8 | ScalarairIRRP100GroupSetpointsReheatUS | read-write | mandatory | Group supply air setpoint in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.9 | ScalarairIRRP100GroupSetpointsReheatMetric | read-write | mandatory | Group supply air setpoint in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.10 | ScalarairIRRP100GroupSetpointsFanSpeedPreference | read-write | mandatory | The preferred fan speed setting. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.11 | ScalarairIRRP100GroupSetpointsFanSpeedControl | read-write | mandatory | The fan speed control setting. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.12 | ScalarairIRRP100GroupSetpointsActiveFlowControlBias | read-write | mandatory | The active flow control bias setting. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3 | NodeairIRRP100GroupConfig | |||
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.1 | ScalarairIRRP100GroupConfigNumberofCoolingUnits | read-write | mandatory | The number of cooling units present in the group. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.2 | ScalarairIRRP100GroupConfigConfigurationType | read-write | mandatory | The group configuration type. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.3 | ScalarairIRRP100GroupConfigCoolGainP | read-write | mandatory | The gain component of the cool PID in hundredths. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.4 | ScalarairIRRP100GroupConfigCoolResetRateI | read-write | mandatory | The integral component of the cool PID in hundredths. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.5 | ScalarairIRRP100GroupConfigCoolDerivativeD | read-write | mandatory | The derivative component of the cool PID in hundredths. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.6 | ScalarairIRRP100GroupConfigHumidifySensitivityBand | read-write | mandatory | The percent relative humidity below the setpoint that will cause the humidifier to run at 100% capacity. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.7 | ScalarairIRRP100GroupConfigReheatGainP | read-write | mandatory | The gain component of the reheat PID in hundredths. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.8 | ScalarairIRRP100GroupConfigReheatResetRateI | read-write | mandatory | The integral component of the reheat PID in hundredths. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.9 | ScalarairIRRP100GroupConfigReheatDerivativeD | read-write | mandatory | The derivative component of the reheat PID in hundredths. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.10 | ScalarairIRRP100GroupConfigNumberofBackupUnits | read-write | mandatory | The number of backup units. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.11 | ScalarairIRRP100GroupConfigRuntimeBalancingEnable | read-write | mandatory | Enable or disable runtime balancing feature. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.12 | ScalarairIRRP100GroupConfigLoadAssistEnable | read-write | mandatory | Enable or disable load assist feature. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.13 | ScalarairIRRP100GroupConfigFullRPBackups | read-write | mandatory | The number of full featured RPs that can be used as backup units. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.14 | ScalarairIRRP100GroupConfigMaxFanSpeed | read-write | mandatory | The maximum desired fan speed setting in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.15 | ScalarairIRRP100GroupConfigNumberOfActiveFlowControllers | read-write | mandatory | The number of active flow controllers present in the group. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.16 | ScalarairIRRP100GroupConfigActiveFlowControllerLampTest | read-write | mandatory | Turns off/on the active flow controller lamp test. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.17 | ScalarairIRRP100GroupConfigAltitudeUS | read-write | mandatory | The group altitude of the units above sea level in feet. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.18 | ScalarairIRRP100GroupConfigAltitudeMetric | read-write | mandatory | The group altitude of the units above sea level in meters. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2 | NodeairIRRP100Unit | |||
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.1 | NodeairIRRP100UnitIdent | |||
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.1 | ScalarairIRRP100UnitIdentID | read-write | mandatory | The unit identification number. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.2 | ScalarairIRRP100UnitIdentName | read-write | mandatory | A character string identifying the unit name. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.3 | ScalarairIRRP100UnitIdentLocation | read-write | mandatory | A character string identifying the unit location. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.4 | ScalarairIRRP100UnitIdentModelNumber | read-only | mandatory | A character string identifying the unit model number. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.5 | ScalarairIRRP100UnitIdentSerialNumber | read-only | mandatory | A character string identifying the unit serial number. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.6 | ScalarairIRRP100UnitIdentFirmwareRevision | read-only | mandatory | A character string identifying the unit firmware version. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.7 | ScalarairIRRP100UnitIdentHardwareRevision | read-only | mandatory | A character string identifying the unit controller hardware revision. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.8 | ScalarairIRRP100UnitIdentManufactureDate | read-only | mandatory | A character string identifying the unit manufacture date. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2 | NodeairIRRP100UnitStatus | |||
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.1 | ScalarairIRRP100UnitStatusOperateMode | read-only | mandatory | The cooling unit operating mode. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.2 | ScalarairIRRP100UnitStatusRackInletTempUS | read-only | mandatory | The unit rack inlet temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.3 | ScalarairIRRP100UnitStatusRackInletTempMetric | read-only | mandatory | The unit rack inlet temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.4 | ScalarairIRRP100UnitStatusSupplyAirTempUS | read-only | mandatory | The unit supply air temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.5 | ScalarairIRRP100UnitStatusSupplyAirTempMetric | read-only | mandatory | The unit supply air temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.6 | ScalarairIRRP100UnitStatusReturnAirTempUS | read-only | mandatory | The unit return air temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.7 | ScalarairIRRP100UnitStatusReturnAirTempMetric | read-only | mandatory | The unit return air temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.8 | ScalarairIRRP100UnitStatusSupplyHumidity | read-only | mandatory | The relative humidity of the supply air in tenths of percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.9 | ScalarairIRRP100UnitStatusReturnHumidity | read-only | mandatory | The relative humidity of the return air in tenths of percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.10 | ScalarairIRRP100UnitStatusAirFlowUS | read-only | mandatory | The unit air flow in cubic feet per minute. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.11 | ScalarairIRRP100UnitStatusAirFlowMetric | read-only | mandatory | The unit air flow in hundredths of liters per second. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.12 | ScalarairIRRP100UnitStatusFanSpeed | read-only | mandatory | The unit average fan speed in tenths of percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.13 | ScalarairIRRP100UnitStatusCoolDemand | read-only | mandatory | The unit cooling demand in tenths of kiloWatts. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.14 | ScalarairIRRP100UnitStatusCoolOutput | read-only | mandatory | The unit cooling output in tenths of kiloWatts. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.15 | ScalarairIRRP100UnitStatusHumidifyDemand | read-only | mandatory | The amount of humidification the unit is demanding from the humidifier in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.16 | ScalarairIRRP100UnitStatusHumidifyOutput | read-only | mandatory | The actual humidification output of the unit in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.17 | ScalarairIRRP100UnitStatusDehumidifyDemand | read-only | mandatory | The amount of dehumidification the unit is demanding in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.18 | ScalarairIRRP100UnitStatusDehumidifyOutput | read-only | mandatory | The actual dehumidification output of the unit in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.19 | ScalarairIRRP100UnitStatusReheatDemand | read-only | mandatory | The amount of heating the unit is demanding from the electric heater in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.20 | ScalarairIRRP100UnitStatusReheatOutput | read-only | mandatory | The actual heating output of the unit in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.21 | ScalarairIRRP100UnitStatusInputState | read-only | mandatory | The state of the input contact. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.22 | ScalarairIRRP100UnitStatusOutputState | read-only | mandatory | The state of the output relay. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.23 | ScalarairIRRP100UnitStatusRackInletTemperature1US | read-only | mandatory | The unit rack inlet temperature sensor in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.24 | ScalarairIRRP100UnitStatusRackInletTemperature1Metric | read-only | mandatory | The unit rack inlet temperature sensor in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.25 | ScalarairIRRP100UnitStatusRackInletTemperature2US | read-only | mandatory | The unit rack inlet temperature sensor in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.26 | ScalarairIRRP100UnitStatusRackInletTemperature2Metric | read-only | mandatory | The unit rack inlet temperature sensor in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.27 | ScalarairIRRP100UnitStatusRackInletTemperature3US | read-only | mandatory | The unit rack inlet temperature sensor in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.28 | ScalarairIRRP100UnitStatusRackInletTemperature3Metric | read-only | mandatory | The unit rack inlet temperature sensor in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.29 | ScalarairIRRP100UnitStatusFilterDPUS | read-only | mandatory | The unit air filter differential pressure in hundredths of inches of water. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.30 | ScalarairIRRP100UnitStatusFilterDPMetric | read-only | mandatory | The unit air filter differential pressure in Pa. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.31 | ScalarairIRRP100UnitStatusContainmtDPUS | read-only | mandatory | The unit containment differential pressure in hundredths of inches of water. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.32 | ScalarairIRRP100UnitStatusContainmtDPMetric | read-only | mandatory | The unit containment differential pressure in Pa. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.33 | ScalarairIRRP100UnitStatusHumidifierCurrent | read-only | mandatory | The humidifier current of the unit in tenths of amperes. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.34 | ScalarairIRRP100UnitStatusHumidifierWaterConductivity | read-only | mandatory | The water conductivity in the humidifier of the unit in microSiemens/cm. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.35 | ScalarairIRRP100UnitStatusCompressorDriveSpeed | read-only | mandatory | The compressor drive speed in hundredths of Hertz. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.36 | ScalarairIRRP100UnitStatusCompressorDrivePower | read-only | mandatory | The compressor drive power consumption in tenths of kiloWatts. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.37 | ScalarairIRRP100UnitStatusCompressorDriveVoltage | read-only | mandatory | The compressor drive voltage consumption in tenths of volts. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.38 | ScalarairIRRP100UnitStatusCompressorDriveCurrent | read-only | mandatory | The compressor drive voltage consumption in tenths of amperes. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.39 | ScalarairIRRP100UnitStatusCompressorDriveDCLinkVoltage | read-only | mandatory | The compressor drive DC link voltage in tenths of volts. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.40 | ScalarairIRRP100UnitStatusCompressorDriveHeatSinkTempUS | read-only | mandatory | The temperature of the compressor drive heatsink in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.41 | ScalarairIRRP100UnitStatusCompressorDriveHeatSinkTempMetric | read-only | mandatory | The temperature of the compressor drive heatsink in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.42 | ScalarairIRRP100UnitStatusCompressorDriveControlCardTempUS | read-only | mandatory | The temperature of the compressor drive control card in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.43 | ScalarairIRRP100UnitStatusCompressorDriveControlCardTempMetric | read-only | mandatory | The temperature of the compressor drive control card in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.44 | ScalarairIRRP100UnitStatusCompressorDriveWarningStatus | read-only | mandatory | The four byte warning status of the compressor drive in hexadecimal. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.45 | ScalarairIRRP100UnitStatusCompressorDriveAlarmStatus | read-only | mandatory | The four byte alarm status of the compressor drive in hexadecimal. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.46 | ScalarairIRRP100UnitStatusSuctionPressureUS | read-only | mandatory | Unit suction pressure in pounds per square inch (PSI). |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.47 | ScalarairIRRP100UnitStatusSuctionPressureMetric | read-only | mandatory | Unit suction pressure in kiloPascals (kPa). |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.48 | ScalarairIRRP100UnitStatusDischargePressureUS | read-only | mandatory | Unit discharge pressure in pounds per square inch (PSI). |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.49 | ScalarairIRRP100UnitStatusDischargePressureMetric | read-only | mandatory | Unit discharge pressure in kiloPascals (kPa). |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.50 | ScalarairIRRP100UnitStatusLeakSensor | read-only | mandatory | The state (no-leak/leak) of the leak sensor. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3 | NodeairIRRP100UnitRunHours | |||
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.1 | ScalarairIRRP100UnitRunHoursAirFilter | read-only | mandatory | Unit air filter run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.2 | ScalarairIRRP100UnitRunHoursCondensatePump | read-only | mandatory | Unit condensate pump run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.3 | ScalarairIRRP100UnitRunHoursHumidifier | read-only | mandatory | Unit fan right power supply run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.4 | ScalarairIRRP100UnitRunHoursFan1 | read-only | mandatory | Unit fan 1 run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.5 | ScalarairIRRP100UnitRunHoursHeater1 | read-only | mandatory | Unit heater 1 run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.6 | ScalarairIRRP100UnitRunHoursFan2 | read-only | mandatory | Unit fan 2 run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.7 | ScalarairIRRP100UnitRunHoursHeater2 | read-only | mandatory | Unit Heater 2 run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.8 | ScalarairIRRP100UnitRunHoursCompressor | read-only | mandatory | Unit compressor run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.9 | ScalarairIRRP100UnitRunHoursSystem | read-only | mandatory | Total system run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4 | NodeairIRRP100UnitServiceIntervals | |||
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.1 | ScalarairIRRP100UnitServiceIntervalAirFilter | read-write | mandatory | Air filter service interval in weeks. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.2 | ScalarairIRRP100UnitServiceIntervalAirFilterAlarm | read-write | mandatory | The air filter service interval alarm enable/disable. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.3 | ScalarairIRRP100UnitServiceIntervalHumidifier | read-write | mandatory | Humidifier service interval in weeks. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.4 | ScalarairIRRP100UnitServiceIntervalHumidifierAlarm | read-write | mandatory | The humidifier service interval alarm enable/disable. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.5 | ScalarairIRRP100UnitServiceIntervalHeater | read-write | mandatory | Heater service interval in weeks. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.6 | ScalarairIRRP100UnitServiceIntervalHeaterAlarm | read-write | mandatory | The heater service interval alarm enable/disable. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.7 | ScalarairIRRP100UnitServiceIntervalCompressor | read-write | mandatory | Compressor service interval in weeks. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.8 | ScalarairIRRP100UnitServiceIntervalCompressorAlarm | read-write | mandatory | The compressor service interval alarm enable/disable. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.9 | ScalarairIRRP100UnitServiceIntervalCondensatePump | read-write | mandatory | Condensate pump service interval in weeks. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.10 | ScalarairIRRP100UnitServiceIntervalCondensatePumpAlarm | read-write | mandatory | The condensate pump service interval alarm enable/disable. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.11 | ScalarairIRRP100UnitServiceIntervalFans | read-write | mandatory | Fans service interval in weeks. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.12 | ScalarairIRRP100UnitServiceIntervalFansAlarm | read-write | mandatory | The fans service interval alarm enable/disable. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.5 | NodeairIRRP100UnitThresholds | |||
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.1 | ScalarairIRRP100UnitThresholdsRackInletHighTempUS | read-write | mandatory | Unit rack inlet air high temperature threshold in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.2 | ScalarairIRRP100UnitThresholdsRackInletHighTempMetric | read-write | mandatory | Unit rack inlet air high temperature threshold in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.3 | ScalarairIRRP100UnitThresholdsSupplyAirHighTempUS | read-write | mandatory | Unit supply air high temperature threshold in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.4 | ScalarairIRRP100UnitThresholdsSupplyAirHighTempMetric | read-write | mandatory | Unit supply air high temperature threshold in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.5 | ScalarairIRRP100UnitThresholdsReturnAirHighTempUS | read-write | mandatory | Unit return air high temperature threshold in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.6 | ScalarairIRRP100UnitThresholdsReturnAirHighTempMetric | read-write | mandatory | Unit return air high temperature threshold in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.7 | ScalarairIRRP100UnitThresholdsSupplyHumidityHigh | read-write | mandatory | Unit supply humidity high threshold in tenths of percent relative humidity. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.8 | ScalarairIRRP100UnitThresholdsSupplyHumidityLow | read-write | mandatory | Unit supply humidity low threshold in tenths of percent relative humidity. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6 | NodeairIRRP100UnitConfig | |||
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.1 | ScalarairIRRP100UnitConfigStartupDelay | read-write | mandatory | The startup delay in seconds. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.2 | ScalarairIRRP100UnitConfigCoolCapacity | read-write | mandatory | The cooling capacity options setting. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.3 | ScalarairIRRP100UnitConfigIdleOnLeakDetect | read-write | mandatory | The idle on leak options setting. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.4 | ScalarairIRRP100UnitConfigInputNormalState | read-write | mandatory | The normal state of the input contact. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.5 | ScalarairIRRP100UnitConfigOutputNormalState | read-write | mandatory | The normal state of the output relay. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.6 | ScalarairIRRP100UnitConfigOutputSource | read-write | mandatory | The source of output relay change. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.7 | ScalarairIRRP100UnitConfigHumidifyEnable | read-write | mandatory | Enable/disable humidification. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.8 | ScalarairIRRP100UnitConfigHumidifierControl | read-write | mandatory | The humidifier drain control. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.9 | ScalarairIRRP100UnitConfigDehumidifyEnable | read-write | mandatory | Enable/disable dehumidification. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.10 | ScalarairIRRP100UnitConfigReheatEnable | read-write | mandatory | Enable/disable reheat. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.11 | ScalarairIRRP100UnitConfigHeatAssistEnable | read-write | mandatory | Enable/disable heat assist. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.12 | ScalarairIRRP100UnitConfigPowerSourceConfig | read-write | mandatory | Configure the input power source: (1) single feed or (2) dual feed. |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.13 | ScalarairIRRP100UnitConfigUnitRoleOverride | read-write | mandatory | When this OID value is (1) automatic, the system determines which units are used as primary units and which units are used as backups. When this OID value is (… |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.14 | ScalarairIRRP100UnitConfigSecondaryPowerFeedCapability | read-write | mandatory | Available on chilled water units. When the power source config setting is set to dual, setting this value to reduced (2) will inhibit the heater and humdifier … |
| 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.15 | ScalarairIRRP100UnitConfigIdleOnCoolFail | read-write | mandatory | When this OID value is (1) enable, the unit idles if it detects that it is blowing warm air into the cold aisle. The unit will attempt to restart at 5 minute i… |
| 1.3.6.1.4.1.318.1.1.13.3.3.2 | NodeairIRRP500 | |||
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1 | NodeairIRRP500Group | |||
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1 | NodeairIRRP500GroupStatus | |||
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.1 | ScalarairIRRP500GroupStatusAirFlowUS | read-only | mandatory | Group air flow in cubic feet per minute. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.2 | ScalarairIRRP500GroupStatusAirFlowMetric | read-only | mandatory | Group air flow in liters per second. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.3 | ScalarairIRRP500GroupStatusMaxRackInletTempUS | read-only | mandatory | Group maximum rack inlet temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.4 | ScalarairIRRP500GroupStatusMaxRackInletTempMetric | read-only | mandatory | Group maximum rack inlet temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.5 | ScalarairIRRP500GroupStatusMinRackInletTempUS | read-only | mandatory | Group minimum rack inlet temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.6 | ScalarairIRRP500GroupStatusMinRackInletTempMetric | read-only | mandatory | Group minimum rack inlet temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.7 | ScalarairIRRP500GroupStatusCoolDemand | read-only | mandatory | Group coolant demand in tenths of kiloWatts. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.8 | ScalarairIRRP500GroupStatusCoolOutput | read-only | mandatory | Group coolant output in tenths of kiloWatts. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.9 | ScalarairIRRP500GroupStatusHumidifyDemand | read-only | mandatory | The amount of humidification the group is demanding from the humidifiers in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.10 | ScalarairIRRP500GroupStatusHumidifyOutput | read-only | mandatory | The actual amount of humidification the group is supplying in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.11 | ScalarairIRRP500GroupStatusDehumidifyDemand | read-only | mandatory | The amount of dehumidification the group is demanding from the electric heaters in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.12 | ScalarairIRRP500GroupStatusDehumidifyOutput | read-only | mandatory | The actual amount of dehumidification the group is supplying in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.13 | ScalarairIRRP500GroupStatusReheatDemand | read-only | mandatory | The amount of heating the group is demanding from the electric heaters in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.14 | ScalarairIRRP500GroupStatusReheatOutput | read-only | mandatory | The actual amount of heating the group is supplying in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.15 | ScalarairIRRP500GroupStatusActiveFlowControlStatus | read-only | mandatory | Status of the active flow control system. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.16 | ScalarairIRRP500GroupStatusDewPointTempUS | read-only | mandatory | Group average dew point temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.17 | ScalarairIRRP500GroupStatusDewPointTempMetric | read-only | mandatory | Group average dew point temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2 | NodeairIRRP500GroupSetpoints | |||
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.1 | ScalarairIRRP500GroupSetpointsCoolUS | read-write | mandatory | Group cooling setpoint in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.2 | ScalarairIRRP500GroupSetpointsCoolMetric | read-write | mandatory | Group cooling setpoint in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.3 | ScalarairIRRP500GroupSetpointsSupplyAirUS | read-write | mandatory | Group supply air setpoint in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.4 | ScalarairIRRP500GroupSetpointsSupplyAirMetric | read-write | mandatory | Group supply air setpoint in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.5 | ScalarairIRRP500GroupSetpointsHumidify | read-write | mandatory | Group humidify setpoint in tenths of percent relative humidity. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.6 | ScalarairIRRP500GroupSetpointsDehumidify | read-write | mandatory | Group dehumidify setpoint in tenths of percent relative humidity. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.7 | ScalarairIRRP500GroupSetpointsDehumidifyDeadband | read-write | mandatory | Group dehumidify deadband in percent relative humidity. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.8 | ScalarairIRRP500GroupSetpointsReheatUS | read-write | mandatory | Group supply air setpoint in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.9 | ScalarairIRRP500GroupSetpointsReheatMetric | read-write | mandatory | Group supply air setpoint in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.10 | ScalarairIRRP500GroupSetpointsFanSpeedPreference | read-write | mandatory | The preferred fan speed setting. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.11 | ScalarairIRRP500GroupSetpointsFanSpeedControl | read-write | mandatory | The fan speed control setting. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.12 | ScalarairIRRP500GroupSetpointsActiveFlowControlBias | read-write | mandatory | The active flow control bias setting. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3 | NodeairIRRP500GroupConfig | |||
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.1 | ScalarairIRRP500GroupConfigNumberofCoolingUnits | read-write | mandatory | The number of cooling units. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.2 | ScalarairIRRP500GroupConfigConfigurationType | read-write | mandatory | The group configuration type. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.3 | ScalarairIRRP500GroupConfigPercentGlycol | read-write | mandatory | The glycol mixture in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.4 | ScalarairIRRP500GroupConfigCoolGainP | read-write | mandatory | The gain component of the cool PID in hundredths. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.5 | ScalarairIRRP500GroupConfigCoolResetRateI | read-write | mandatory | The integral component of the cool PID in hundredths. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.6 | ScalarairIRRP500GroupConfigCoolDerivativeD | read-write | mandatory | The derivative component of the cool PID in hundredths. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.7 | ScalarairIRRP500GroupConfigHumidifySensitivityBand | read-write | mandatory | The percent relative humidity below the setpoint that will cause the humidifier to run at 100% capacity. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.8 | ScalarairIRRP500GroupConfigReheatGainP | read-write | mandatory | The gain component of the reheat PID in hundredths. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.9 | ScalarairIRRP500GroupConfigReheatResetRateI | read-write | mandatory | The integral component of the reheat PID in hundredths. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.10 | ScalarairIRRP500GroupConfigReheatDerivativeD | read-write | mandatory | The derivative component of the reheat PID in hundredths. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.11 | ScalarairIRRP500GroupConfigMaxFanSpeed | read-write | mandatory | The maximum desired fan speed setting in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.12 | ScalarairIRRP500GroupConfigNumberofBackupUnits | read-write | mandatory | The number of backup units. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.13 | ScalarairIRRP500GroupConfigRuntimeBalancingEnable | read-write | mandatory | Enable or disable runtime balancing feature. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.14 | ScalarairIRRP500GroupConfigLoadAssistEnable | read-write | mandatory | Enable or disable load assist feature. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.15 | ScalarairIRRP500GroupConfigFullRPBackups | read-write | mandatory | The number of full featured RPs that can be used as backup units. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.16 | ScalarairIRRP500GroupConfigNumberOfActiveFlowControllers | read-write | mandatory | The number of active flow controllers present in the group. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.17 | ScalarairIRRP500GroupConfigActiveFlowControllerLampTest | read-write | mandatory | Turns off/on the active flow controller lamp test. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.18 | ScalarairIRRP500GroupConfigAltitudeUS | read-write | mandatory | The group altitude of the units above sea level in feet. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.19 | ScalarairIRRP500GroupConfigAltitudeMetric | read-write | mandatory | The group altitude of the units above sea level in meters. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2 | NodeairIRRP500Unit | |||
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.1 | NodeairIRRP500UnitIdent | |||
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.1 | ScalarairIRRP500UnitIdentID | read-write | mandatory | The unit identification number. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.2 | ScalarairIRRP500UnitIdentName | read-write | mandatory | A character string identifying the unit name. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.3 | ScalarairIRRP500UnitIdentLocation | read-write | mandatory | A character string identifying the unit location. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.4 | ScalarairIRRP500UnitIdentModelNumber | read-only | mandatory | A character string identifying the unit model number. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.5 | ScalarairIRRP500UnitIdentSerialNumber | read-only | mandatory | A character string identifying the unit serial number. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.6 | ScalarairIRRP500UnitIdentFirmwareRevision | read-only | mandatory | A character string identifying the unit firmware version. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.7 | ScalarairIRRP500UnitIdentHardwareRevision | read-only | mandatory | A character string identifying the unit controller hardware revision. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.8 | ScalarairIRRP500UnitIdentManufactureDate | read-only | mandatory | A character string identifying the unit manufacture date. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2 | NodeairIRRP500UnitStatus | |||
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.1 | ScalarairIRRP500UnitStatusOperateMode | read-only | mandatory | The cooling unit operating mode. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.2 | ScalarairIRRP500UnitStatusMaximumRackInletTempUS | read-only | mandatory | The maximum unit rack inlet temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.3 | ScalarairIRRP500UnitStatusMaximumRackInletTempMetric | read-only | mandatory | The maximum unit rack inlet temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.4 | ScalarairIRRP500UnitStatusSupplyAirTempUS | read-only | mandatory | The unit supply air temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.5 | ScalarairIRRP500UnitStatusSupplyAirTempMetric | read-only | mandatory | The unit supply air temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.6 | ScalarairIRRP500UnitStatusReturnAirTempUS | read-only | mandatory | The unit return air temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.7 | ScalarairIRRP500UnitStatusReturnAirTempMetric | read-only | mandatory | The unit return air temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.8 | ScalarairIRRP500UnitStatusSupplyHumidity | read-only | mandatory | The relative humidity of the supply air in tenths of percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.9 | ScalarairIRRP500UnitStatusReturnHumidity | read-only | mandatory | The relative humidity of the return air in tenths of percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.10 | ScalarairIRRP500UnitStatusAirFlowUS | read-only | mandatory | The unit air flow in cubic feet per minute. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.11 | ScalarairIRRP500UnitStatusAirFlowMetric | read-only | mandatory | The unit air flow in hundredths of liters per second. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.12 | ScalarairIRRP500UnitStatusFanSpeed | read-only | mandatory | The unit average fan speed in tenths of percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.13 | ScalarairIRRP500UnitStatusCoolDemand | read-only | mandatory | The unit cooling demand in tenths of kiloWatts. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.14 | ScalarairIRRP500UnitStatusCoolOutput | read-only | mandatory | The unit cooling output in tenths of kiloWatts. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.15 | ScalarairIRRP500UnitStatusHumidifyDemand | read-only | mandatory | The amount of humidification the unit is demanding from the humidifier in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.16 | ScalarairIRRP500UnitStatusHumidifyOutput | read-only | mandatory | The actual humidification output of the unit in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.17 | ScalarairIRRP500UnitStatusDehumidifyDemand | read-only | mandatory | The amount of dehumidification the unit is demanding in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.18 | ScalarairIRRP500UnitStatusDehumidifyOutput | read-only | mandatory | The actual dehumidification output of the unit in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.19 | ScalarairIRRP500UnitStatusReheatDemand | read-only | mandatory | The amount of heating the unit is demanding from the electric heater in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.20 | ScalarairIRRP500UnitStatusReheatOutput | read-only | mandatory | The actual heating output of the unit in percent. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.21 | ScalarairIRRP500UnitStatusInputState | read-only | mandatory | The state of the input contact. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.22 | ScalarairIRRP500UnitStatusOutputState | read-only | mandatory | The state of the output relay. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.23 | ScalarairIRRP500UnitStatusRackInletTemperature1US | read-only | mandatory | The unit rack inlet temperature sensor in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.24 | ScalarairIRRP500UnitStatusRackInletTemperature1Metric | read-only | mandatory | The unit rack inlet temperature sensor in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.25 | ScalarairIRRP500UnitStatusRackInletTemperature2US | read-only | mandatory | The unit rack inlet temperature sensor in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.26 | ScalarairIRRP500UnitStatusRackInletTemperature2Metric | read-only | mandatory | The unit rack inlet temperature sensor in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.27 | ScalarairIRRP500UnitStatusRackInletTemperature3US | read-only | mandatory | The unit rack inlet temperature sensor in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.28 | ScalarairIRRP500UnitStatusRackInletTemperature3Metric | read-only | mandatory | The unit rack inlet temperature sensor in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.29 | ScalarairIRRP500UnitStatusContainmtDPUS | read-only | mandatory | The unit containment differential pressure in hundredths of inches of water. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.30 | ScalarairIRRP500UnitStatusContainmtDPMetric | read-only | mandatory | The unit containment differential pressure in Pa. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.31 | ScalarairIRRP500UnitStatusFilterDPUS | read-only | mandatory | The unit air filter differential pressure in hundredths of inches of water. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.32 | ScalarairIRRP500UnitStatusFilterDPMetric | read-only | mandatory | The unit air filter differential pressure in Pa. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.33 | ScalarairIRRP500UnitStatusHumidifierCurrent | read-only | mandatory | The humidifier current of the unit in tenths of amperes. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.34 | ScalarairIRRP500UnitStatusHumidifierWaterConductivity | read-only | mandatory | The water conductivity in the humidifier of the unit in microSiemens/cm. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.35 | ScalarairIRRP500UnitStatusActivePowerSource | read-only | mandatory | The power source that is powering the unit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.36 | ScalarairIRRP500UnitStatusFluidValvePosition | read-only | mandatory | The fluid valve position in percent open. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.37 | ScalarairIRRP500UnitStatusFluidFlowUS | read-only | mandatory | The fluid flow in tenths of gallons per minute. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.38 | ScalarairIRRP500UnitStatusFluidFlowMetric | read-only | mandatory | The fluid flow in hundredths of liters per second. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.39 | ScalarairIRRP500UnitStatusEnteringFluidTemperatureUS | read-only | mandatory | The temperature of the entering fluid in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.40 | ScalarairIRRP500UnitStatusEnteringFluidTemperatureMetric | read-only | mandatory | The temperature of the entering fluid in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.41 | ScalarairIRRP500UnitStatusLeavingFluidTemperatureUS | read-only | mandatory | The temperature of the Leaving fluid in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.42 | ScalarairIRRP500UnitStatusLeavingFluidTemperatureMetric | read-only | mandatory | The temperature of the Leaving fluid in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.43 | ScalarairIRRP500UnitStatusLeakSensor | read-only | mandatory | The state (no-leak/leak) of the leak sensor. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3 | NodeairIRRP500UnitRunHours | |||
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.1 | ScalarairIRRP500UnitRunHoursAirFilter | read-only | mandatory | Unit air filter run hours in hours. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.2 | ScalarairIRRP500UnitRunHoursCondensatePump | read-only | mandatory | Unit condensate pump run hours in hours. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.3 | ScalarairIRRP500UnitRunHoursHumidifier | read-only | mandatory | Unit fan right power supply run hours in hours. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.4 | ScalarairIRRP500UnitRunHoursFan1 | read-only | mandatory | Unit fan 1 run hours in hours. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.5 | ScalarairIRRP500UnitRunHoursHeater1 | read-only | mandatory | Unit heater 1 run hours in hours. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.6 | ScalarairIRRP500UnitRunHoursFan2 | read-only | mandatory | Unit fan 2 run hours in hours. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.7 | ScalarairIRRP500UnitRunHoursHeater2 | read-only | mandatory | Unit Heater 2 run hours in hours. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.8 | ScalarairIRRP500UnitRunHoursFan3 | read-only | mandatory | Unit fan 3 run hours in hours. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.9 | ScalarairIRRP500UnitRunHoursHeater3 | read-only | mandatory | Unit heater 3 run hours in hours. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.10 | ScalarairIRRP500UnitRunHoursSystem | read-only | mandatory | Total system run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4 | NodeairIRRP500UnitServiceIntervals | |||
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.1 | ScalarairIRRP500UnitServiceIntervalAirFilter | read-write | mandatory | Air filter service interval in weeks. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.2 | ScalarairIRRP500UnitServiceIntervalAirFilterAlarm | read-write | mandatory | The air filter service interval alarm enable/disable. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.3 | ScalarairIRRP500UnitServiceIntervalHumidifier | read-write | mandatory | Humidifier service interval in weeks. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.4 | ScalarairIRRP500UnitServiceIntervalHumidifierAlarm | read-write | mandatory | The humidifier service interval alarm enable/disable. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.5 | ScalarairIRRP500UnitServiceIntervalHeater | read-write | mandatory | Heater service interval in weeks. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.6 | ScalarairIRRP500UnitServiceIntervalHeaterAlarm | read-write | mandatory | The heater service interval alarm enable/disable. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.7 | ScalarairIRRP500UnitServiceIntervalCondensatePump | read-write | mandatory | Condensate pump service interval in weeks. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.8 | ScalarairIRRP500UnitServiceIntervalCondensatePumpAlarm | read-write | mandatory | The condensate pump service interval alarm enable/disable. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.9 | ScalarairIRRP500UnitServiceIntervalFans | read-write | mandatory | Fans service interval in weeks. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.10 | ScalarairIRRP500UnitServiceIntervalFansAlarm | read-write | mandatory | The fans service interval alarm enable/disable. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5 | NodeairIRRP500UnitThresholds | |||
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.1 | ScalarairIRRP500UnitThresholdsRackInletHighTempUS | read-write | mandatory | Unit rack inlet air high temperature threshold in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.2 | ScalarairIRRP500UnitThresholdsRackInletHighTempMetric | read-write | mandatory | Unit rack inlet air high temperature threshold in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.3 | ScalarairIRRP500UnitThresholdsSupplyAirHighTempUS | read-write | mandatory | Unit supply air temperature high threshold in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.4 | ScalarairIRRP500UnitThresholdsSupplyAirHighTempMetric | read-write | mandatory | Unit supply air high temperature high threshold in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.5 | ScalarairIRRP500UnitThresholdsReturnAirHighTempUS | read-write | mandatory | Unit return air high temperature threshold in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.6 | ScalarairIRRP500UnitThresholdsReturnAirHighTempMetric | read-write | mandatory | Unit return air high temperature threshold in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.7 | ScalarairIRRP500UnitThresholdsReturnHumidityHigh | read-write | mandatory | Unit return humidity high threshold in tenths of percent relative humidity. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.8 | ScalarairIRRP500UnitThresholdsReturnHumidityLow | read-write | mandatory | Unit return humidity low threshold in tenths of percent relative humidity. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.9 | ScalarairIRRP500UnitThresholdsEnteringFluidHighTempUS | read-write | mandatory | Entering fluid high temperature threshold in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.10 | ScalarairIRRP500UnitThresholdsEnteringFluidHighTempMetric | read-write | mandatory | Entering fluid high temperature threshold in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6 | NodeairIRRP500UnitConfig | |||
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.1 | ScalarairIRRP500UnitConfigStartupDelay | read-write | mandatory | The startup delay in seconds. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.2 | ScalarairIRRP500UnitConfigCoolCapacity | read-write | mandatory | The cooling capacity options setting. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.3 | ScalarairIRRP500UnitConfigIdleOnLeakDetect | read-write | mandatory | The idle on leak options setting. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.4 | ScalarairIRRP500UnitConfigInputNormalState | read-write | mandatory | The normal state of the input contact. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.5 | ScalarairIRRP500UnitConfigOutputNormalState | read-write | mandatory | The normal state of the output relay. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.6 | ScalarairIRRP500UnitConfigOutputSource | read-write | mandatory | The source of output relay change. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.7 | ScalarairIRRP500UnitConfigHumidifyEnable | read-write | mandatory | Enable/disable humidification. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.8 | ScalarairIRRP500UnitConfigHumidifierControl | read-write | mandatory | The humidifier drain control. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.9 | ScalarairIRRP500UnitConfigDehumidifyEnable | read-write | mandatory | Enable/disable dehumidification. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.10 | ScalarairIRRP500UnitConfigReheatEnable | read-write | mandatory | Enable/disable reheat. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.11 | ScalarairIRRP500UnitConfigHeatAssistEnable | read-write | mandatory | Enable/disable heat assist. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.12 | ScalarairIRRP500UnitConfigPowerSourceConfig | read-write | mandatory | Configure the input power source: (1) single feed or (2) dual feed. |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.13 | ScalarairIRRP500UnitConfigUnitRoleOverride | read-write | mandatory | When this OID value is (1) automatic, the system determines which units are used as primary units and which units are used as backups. When this OID value is (… |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.14 | ScalarairIRRP500UnitConfigSecondaryPowerFeedCapability | read-write | mandatory | Available on chilled water units. When the power source config setting is set to dual, setting this value to reduced (2) will inhibit the heater and humdifier … |
| 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.15 | ScalarairIRRP500UnitConfigIdleOnCoolFail | read-write | mandatory | When this OID value is (1) enable, the unit idles if it detects that it is blowing warm air into the cold aisle. The unit will attempt to restart at 5 minute i… |
| 1.3.6.1.4.1.318.1.1.13.3.4 | NodeairIRSC | |||
| 1.3.6.1.4.1.318.1.1.13.3.4.1 | NodeairIRSCUnit | |||
| 1.3.6.1.4.1.318.1.1.13.3.4.1.1 | NodeairIRSCUnitIdent | |||
| 1.3.6.1.4.1.318.1.1.13.3.4.1.1.1 | ScalarairIRSCUnitIdentName | read-write | mandatory | A character string identifying the unit name. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.1.2 | ScalarairIRSCUnitIdentLocation | read-write | mandatory | A character string identifying the unit location. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.1.3 | ScalarairIRSCUnitIdentModelNumber | read-only | mandatory | A character string identifying the unit model number. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.1.4 | ScalarairIRSCUnitIdentSerialNumber | read-only | mandatory | A character string identifying the unit serial number. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.1.5 | ScalarairIRSCUnitIdentFirmwareRevision | read-only | mandatory | A character string identifying the unit firmware version. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.1.6 | ScalarairIRSCUnitIdentHardwareRevision | read-only | mandatory | A character string identifying the unit controller hardware revision. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.1.7 | ScalarairIRSCUnitIdentManufactureDate | read-only | mandatory | A character string identifying the unit manufacture date. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2 | NodeairIRSCUnitStatus | |||
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.1 | ScalarairIRSCUnitStatusOperateMode | read-only | mandatory | The cooling unit operating mode. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.2 | ScalarairIRSCUnitStatusCoolOutput | read-only | mandatory | The unit cooling output in tenths of kW. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.3 | ScalarairIRSCUnitStatusCoolDemand | read-only | mandatory | The unit cooling demand in tenths of kW. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.4 | ScalarairIRSCUnitStatusAirFlowUS | read-only | mandatory | The unit air flow in cubic feet per minute. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.5 | ScalarairIRSCUnitStatusAirFlowMetric | read-only | mandatory | The unit air flow in liters per second. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.6 | ScalarairIRSCUnitStatusRackInletTempUS | read-only | mandatory | The unit rack inlet temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.7 | ScalarairIRSCUnitStatusRackInletTempMetric | read-only | mandatory | The unit rack inlet temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.8 | ScalarairIRSCUnitStatusSupplyAirTempUS | read-only | mandatory | The unit supply air temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.9 | ScalarairIRSCUnitStatusSupplyAirTempMetric | read-only | mandatory | The unit supply air temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.10 | ScalarairIRSCUnitStatusReturnAirTempUS | read-only | mandatory | The unit return air temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.11 | ScalarairIRSCUnitStatusReturnAirTempMetric | read-only | mandatory | The unit return air temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.12 | ScalarairIRSCUnitStatusSuctionTempUS | read-only | mandatory | The unit suction temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.13 | ScalarairIRSCUnitStatusSuctionTempMetric | read-only | mandatory | The unit suction temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.14 | ScalarairIRSCUnitStatusSuperheatTempUS | read-only | mandatory | The unit superheat temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.15 | ScalarairIRSCUnitStatusSuperheatTempMetric | read-only | mandatory | The unit superheat temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.16 | ScalarairIRSCUnitStatusContainmtDPUS | read-only | mandatory | The unit containment differential pressure in hundredths of inches of water. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.17 | ScalarairIRSCUnitStatusContainmtDPMetric | read-only | mandatory | The unit containment differential pressure in Pa. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.18 | ScalarairIRSCUnitStatusFilterDPUS | read-only | mandatory | The unit air filter differential pressure in hundredths of inches of water. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.19 | ScalarairIRSCUnitStatusFilterDPMetric | read-only | mandatory | The unit air filter differential pressure in Pa. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.20 | ScalarairIRSCUnitStatusSuctionPressureUS | read-only | mandatory | Unit suction pressure in pounds per square inch (PSI). |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.21 | ScalarairIRSCUnitStatusSuctionPressureMetric | read-only | mandatory | Unit suction pressure in kiloPascals (kPa). |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.22 | ScalarairIRSCUnitStatusDischargePressureUS | read-only | mandatory | Unit discharge pressure in pounds per square inch (PSI). |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.23 | ScalarairIRSCUnitStatusDischargePressureMetric | read-only | mandatory | Unit discharge pressure in kiloPascals (kPa). |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.24 | ScalarairIRSCUnitStatusEvaporatorFanSpeed | read-only | mandatory | The unit average evaporator fan speed in tenths of percent. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.25 | ScalarairIRSCUnitStatusCondenserFanSpeed | read-only | mandatory | The unit average condenser fan speed in tenths of percent. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.26 | ScalarairIRSCUnitStatusInputState | read-only | mandatory | The state of the input contact. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.27 | ScalarairIRSCUnitStatusOutputState | read-only | mandatory | The state of the output relay. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.28 | ScalarairIRSCUnitStatusCondOutletTempUS | read-only | mandatory | The unit condenser outlet air temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.29 | ScalarairIRSCUnitStatusCondOutletTempMetric | read-only | mandatory | The unit condenser outlet air temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.30 | ScalarairIRSCUnitStatusCondInletTempUS | read-only | mandatory | The unit condenser inlet air temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.31 | ScalarairIRSCUnitStatusCondInletTempMetric | read-only | mandatory | The unit condenser inlet air temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.32 | ScalarairIRSCUnitStatusCompressor | read-only | mandatory | The state (off/on) of the compressor. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.2.33 | ScalarairIRSCUnitStatusLeakSensor | read-only | mandatory | The state (no-leak/leak) of the leak sensor. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.3 | NodeairIRSCUnitRunHours | |||
| 1.3.6.1.4.1.318.1.1.13.3.4.1.3.1 | ScalarairIRSCUnitRunHoursAirFilter | read-only | mandatory | Unit air filter run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.3.2 | ScalarairIRSCUnitRunHoursEvaporatorFan1 | read-only | mandatory | Unit evaporator fan 1 run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.3.3 | ScalarairIRSCUnitRunHoursEvaporatorFan2 | read-only | mandatory | Unit evaporator fan 2 run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.3.4 | ScalarairIRSCUnitRunHoursEvaporatorFan3 | read-only | mandatory | Unit evaporator fan 3 run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.3.5 | ScalarairIRSCUnitRunHoursCondenserFan1 | read-only | mandatory | Unit condenser fan 1 run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.3.6 | ScalarairIRSCUnitRunHoursCondenserFan2 | read-only | mandatory | Unit condenser fan 2 run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.3.7 | ScalarairIRSCUnitRunHoursCondenserFan3 | read-only | mandatory | Unit condenser fan 3 run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.3.8 | ScalarairIRSCUnitRunHoursFanPowerSupplyLeft | read-only | mandatory | Unit fan left power supply run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.3.9 | ScalarairIRSCUnitRunHoursFanPowerSupplyRight | read-only | mandatory | Unit fan right power supply run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.3.10 | ScalarairIRSCUnitRunHoursCondensatePump | read-only | mandatory | Unit condensate pump run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.3.11 | ScalarairIRSCUnitRunHoursCompressor | read-only | mandatory | Unit compressor run hours. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.4 | NodeairIRSCUnitServiceIntervals | |||
| 1.3.6.1.4.1.318.1.1.13.3.4.1.4.1 | ScalarairIRSCUnitServiceIntervalsAirFilter | read-write | mandatory | Air filter service interval in weeks. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.4.2 | ScalarairIRSCUnitServiceIntervalsAirFilterAlarm | read-write | mandatory | The air filter service interval alarm enable/disable. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.5 | NodeairIRSCUnitThresholds | |||
| 1.3.6.1.4.1.318.1.1.13.3.4.1.5.1 | ScalarairIRSCUnitThresholdsRackInletHighTempUS | read-write | mandatory | Unit rack inlet air high temperature threshold in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.5.2 | ScalarairIRSCUnitThresholdsRackInletHighTempMetric | read-write | mandatory | Unit rack inlet air high temperature threshold in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.5.3 | ScalarairIRSCUnitThresholdsSupplyAirHighTempUS | read-write | mandatory | Unit supply air high temperature threshold in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.5.4 | ScalarairIRSCUnitThresholdsSupplyAirHighTempMetric | read-write | mandatory | Unit supply air high temperature threshold in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.5.5 | ScalarairIRSCUnitThresholdsReturnAirHighTempUS | read-write | mandatory | Unit return air high temperature threshold in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.5.6 | ScalarairIRSCUnitThresholdsReturnAirHighTempMetric | read-write | mandatory | Unit return air high temperature threshold in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.6 | NodeairIRSCUnitSetpoints | |||
| 1.3.6.1.4.1.318.1.1.13.3.4.1.6.1 | ScalarairIRSCUnitSetptsCoolSetpointUS | read-write | mandatory | Unit cooling setpoint in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.6.2 | ScalarairIRSCUnitSetptsCoolSetpointMetric | read-write | mandatory | Unit cooling setpoint in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.6.3 | ScalarairIRSCUnitSetptsCoolDeadbandUS | read-write | mandatory | Unit cooling deadband in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.6.4 | ScalarairIRSCUnitSetptsCoolDeadbandMetric | read-write | mandatory | Unit cooling deadband in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.6.5 | ScalarairIRSCUnitSetptsFanSpeedPreference | read-write | mandatory | The preferred fan speed setting. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.6.6 | ScalarairIRSCUnitSetptsSupplyAirSetpointUS | read-write | mandatory | Unit supply air setpoint in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.6.7 | ScalarairIRSCUnitSetptsSupplyAirSetpointMetric | read-write | mandatory | Unit supply air setpoint in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.7 | NodeairIRSCUnitConfig | |||
| 1.3.6.1.4.1.318.1.1.13.3.4.1.7.1 | ScalarairIRSCUnitConfigConfigurationType | read-write | mandatory | The unit configuration type. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.7.2 | ScalarairIRSCUnitConfigCapacityControlType | read-write | mandatory | The unit capacity control. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.7.3 | ScalarairIRSCUnitConfigStartupDelay | read-write | mandatory | The startup delay in seconds. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.7.4 | ScalarairIRSCUnitConfigIdleOnLeakDetect | read-write | mandatory | The idle on leak options setting. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.7.5 | ScalarairIRSCUnitConfigInputNormalState | read-write | mandatory | The normal state of the input contact. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.7.6 | ScalarairIRSCUnitConfigOutputNormalState | read-write | mandatory | The normal state of the output relay. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.7.7 | ScalarairIRSCUnitConfigOutputSource | read-write | mandatory | The source of output relay change. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.7.8 | ScalarairIRSCUnitConfigAltitudeUS | read-write | mandatory | The altitude of the unit above sea level in feet. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.7.9 | ScalarairIRSCUnitConfigAltitudeMetric | read-write | mandatory | The altitude of the unit above sea level in meters. |
| 1.3.6.1.4.1.318.1.1.13.3.4.1.7.10 | ScalarairIRSCUnitConfigOpControl | read-write | mandatory | The unit operational control. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2 | NodeairIRSCGroup | |||
| 1.3.6.1.4.1.318.1.1.13.3.4.2.1 | NodeairIRSCGroupStatus | |||
| 1.3.6.1.4.1.318.1.1.13.3.4.2.1.1 | ScalarairIRSCGroupStatusCoolOutput | read-only | mandatory | The group cooling output in tenths of kW. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.1.2 | ScalarairIRSCGroupStatusCoolDemand | read-only | mandatory | The group cooling demand in tenths of kW. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.1.3 | ScalarairIRSCGroupStatusAirFlowUS | read-only | mandatory | The group air flow in cubic feet per minute. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.1.4 | ScalarairIRSCGroupStatusAirFlowMetric | read-only | mandatory | The group air flow in liters per second. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.1.5 | ScalarairIRSCGroupStatusMaxRackInletTempUS | read-only | mandatory | The group maximum rack inlet temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.1.6 | ScalarairIRSCGroupStatusMaxRackInletTempMetric | read-only | mandatory | The group maximum rack inlet temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.1.7 | ScalarairIRSCGroupStatusMinRackInletTempUS | read-only | mandatory | The group minimum rack inlet temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.1.8 | ScalarairIRSCGroupStatusMinRackInletTempMetric | read-only | mandatory | The group minimum rack inlet temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.1.9 | ScalarairIRSCGroupStatusMaxReturnAirTempUS | read-only | mandatory | The group maximum return air temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.1.10 | ScalarairIRSCGroupStatusMaxReturnAirTempMetric | read-only | mandatory | The group maximum return air temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.1.11 | ScalarairIRSCGroupStatusMinReturnAirTempUS | read-only | mandatory | The group minimum return air temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.1.12 | ScalarairIRSCGroupStatusMinReturnAirTempMetric | read-only | mandatory | The group minimum return air temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.1.13 | ScalarairIRSCGroupStatusActiveFlowControlStatus | read-only | mandatory | Status of the active flow control system. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.2 | NodeairIRSCGroupSetpoints | |||
| 1.3.6.1.4.1.318.1.1.13.3.4.2.2.1 | ScalarairIRSCGroupSetptsCoolSetpointUS | read-write | mandatory | Group cooling setpoint in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.2.2 | ScalarairIRSCGroupSetptsCoolSetpointMetric | read-write | mandatory | Group cooling setpoint in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.2.3 | ScalarairIRSCGroupSetptsCoolDeadbandUS | read-write | mandatory | Group cooling deadband in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.2.4 | ScalarairIRSCGroupSetptsCoolDeadbandMetric | read-write | mandatory | Group cooling deadband in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.2.5 | ScalarairIRSCGroupSetptsFanSpeedPreference | read-write | mandatory | The group preferred fan speed setting. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.2.6 | ScalarairIRSCGroupSetptsSupplyAirSetpointUS | read-write | mandatory | Group supply air setpoint in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.2.7 | ScalarairIRSCGroupSetptsSupplyAirSetpointMetric | read-write | mandatory | Group supply air setpoint in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.2.8 | ScalarairIRSCGroupSetpointsActiveFlowControlBias | read-write | mandatory | The active flow control bias setting. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.3 | NodeairIRSCGroupConfig | |||
| 1.3.6.1.4.1.318.1.1.13.3.4.2.3.1 | ScalarairIRSCGroupConfigNumberofCoolingUnits | read-write | mandatory | The number of cooling units. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.3.2 | ScalarairIRSCGroupConfigConfigurationType | read-write | mandatory | The group configuration type. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.3.3 | ScalarairIRSCGroupConfigCapacityControlType | read-write | mandatory | The group capacity control. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.3.4 | ScalarairIRSCGroupConfigAltitudeUS | read-write | mandatory | The group altitude of the units above sea level in feet. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.3.5 | ScalarairIRSCGroupConfigAltitudeMetric | read-write | mandatory | The group altitude of the units above sea level in meters. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.3.6 | ScalarairIRSCGroupConfigFanSpeedControl | read-write | mandatory | The group fan speed control. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.3.7 | ScalarairIRSCGroupConfigNumberOfActiveFlowControllers | read-write | mandatory | The number of active flow controllers present in the group. |
| 1.3.6.1.4.1.318.1.1.13.3.4.2.3.8 | ScalarairIRSCGroupConfigActiveFlowControllerLampTest | read-write | mandatory | Turns off/on the active flow controller lamp test. |
| 1.3.6.1.4.1.318.1.1.13.4 | NodeairIRGen2 | |||
| 1.3.6.1.4.1.318.1.1.13.4.1 | NodeairIRG2Ident | |||
| 1.3.6.1.4.1.318.1.1.13.4.1.1 | ScalarairIRG2IdentName | read-write | mandatory | A character string identifying the unit name. |
| 1.3.6.1.4.1.318.1.1.13.4.1.2 | ScalarairIRG2IdentLocation | read-write | mandatory | A character string identifying the unit location. |
| 1.3.6.1.4.1.318.1.1.13.4.1.3 | ScalarairIRG2IdentModelNumber | read-only | mandatory | A character string identifying the unit model number. |
| 1.3.6.1.4.1.318.1.1.13.4.1.4 | ScalarairIRG2IdentSerialNumber | read-only | mandatory | A character string identifying the unit serial number. |
| 1.3.6.1.4.1.318.1.1.13.4.1.5 | ScalarairIRG2IdentFirmwareRevision | read-only | mandatory | A character string identifying the unit firmware version. |
| 1.3.6.1.4.1.318.1.1.13.4.1.6 | ScalarairIRG2IdentHardwareRevision | read-only | mandatory | A character string identifying the unit controller hardware revision. |
| 1.3.6.1.4.1.318.1.1.13.4.1.7 | ScalarairIRG2IdentManufactureDate | read-only | mandatory | A character string identifying the unit manufacture date. |
| 1.3.6.1.4.1.318.1.1.13.4.1.8 | ScalarairIRG2IdentUnitSysOID | read-only | mandatory | This OID contains an OID path to the device's top level unit data. |
| 1.3.6.1.4.1.318.1.1.13.4.1.9 | ScalarairIRG2IdentGroupSysOID | read-only | mandatory | This OID contains an OID path to the device's top level group data. |
| 1.3.6.1.4.1.318.1.1.13.4.2 | NodeairIRG2Group | |||
| 1.3.6.1.4.1.318.1.1.13.4.2.1 | NodeairIRG2GroupStatus | |||
| 1.3.6.1.4.1.318.1.1.13.4.2.1.1 | ScalarairIRG2GroupStatusCoolOutput | read-only | mandatory | The group cooling output in tenths of kilowatts (kW). |
| 1.3.6.1.4.1.318.1.1.13.4.2.1.2 | ScalarairIRG2GroupStatusCoolDemand | read-only | mandatory | The group cooling demand in tenths of kilowatts (kW). |
| 1.3.6.1.4.1.318.1.1.13.4.2.1.3 | ScalarairIRG2GroupStatusAirFlowUS | read-only | mandatory | The group air flow in cubic feet per minute. |
| 1.3.6.1.4.1.318.1.1.13.4.2.1.4 | ScalarairIRG2GroupStatusAirFlowMetric | read-only | mandatory | The group air flow in hundredths of liters per second. |
| 1.3.6.1.4.1.318.1.1.13.4.2.1.5 | ScalarairIRG2GroupStatusMaxRackInletTempUS | read-only | mandatory | The group maximum rack inlet temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.4.2.1.6 | ScalarairIRG2GroupStatusMaxRackInletTempMetric | read-only | mandatory | The group maximum rack inlet temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.4.2.1.7 | ScalarairIRG2GroupStatusMinRackInletTempUS | read-only | mandatory | The group minimum rack inlet temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.4.2.1.8 | ScalarairIRG2GroupStatusMinRackInletTempMetric | read-only | mandatory | The group minimum rack inlet temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.4.2.1.9 | ScalarairIRG2GroupStatusMaxReturnAirTempUS | read-only | mandatory | The group maximum return air temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.4.2.1.10 | ScalarairIRG2GroupStatusMaxReturnAirTempMetric | read-only | mandatory | The group maximum return air temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.4.2.1.11 | ScalarairIRG2GroupStatusMinReturnAirTempUS | read-only | mandatory | The group minimum return air temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.4.2.1.12 | ScalarairIRG2GroupStatusMinReturnAirTempMetric | read-only | mandatory | The group minimum return air temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.4.2.1.13 | ScalarairIRG2GroupStatusActiveFlowControlStatus | read-only | mandatory | Status of the active flow control system. |
| 1.3.6.1.4.1.318.1.1.13.4.2.2 | NodeairIRG2GroupSetpoints | |||
| 1.3.6.1.4.1.318.1.1.13.4.2.2.1 | ScalarairIRG2GroupSetptsCoolSetpointUS | read-write | mandatory | Group cooling setpoint in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.4.2.2.2 | ScalarairIRG2GroupSetptsCoolSetpointMetric | read-write | mandatory | Group cooling setpoint in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.4.2.2.3 | ScalarairIRG2GroupSetptsCoolDeadbandUS | read-write | mandatory | Group cooling deadband in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.4.2.2.4 | ScalarairIRG2GroupSetptsCoolDeadbandMetric | read-write | mandatory | Group cooling deadband in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.4.2.2.5 | ScalarairIRG2GroupSetptsFanSpeedPreference | read-write | mandatory | The group preferred fan speed setting. |
| 1.3.6.1.4.1.318.1.1.13.4.2.2.6 | ScalarairIRG2GroupSetptsSupplyAirSetpointUS | read-write | mandatory | Group supply air setpoint in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.4.2.2.7 | ScalarairIRG2GroupSetptsSupplyAirSetpointMetric | read-write | mandatory | Group supply air setpoint in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.4.2.2.8 | ScalarairIRG2GroupSetpointsActiveFlowControlBias | read-write | mandatory | The active flow control bias setting. |
| 1.3.6.1.4.1.318.1.1.13.4.2.3 | NodeairIRG2GroupConfig | |||
| 1.3.6.1.4.1.318.1.1.13.4.2.3.1 | ScalarairIRG2GroupConfigNumberofCoolingUnits | read-write | mandatory | The number of cooling units. |
| 1.3.6.1.4.1.318.1.1.13.4.2.3.2 | ScalarairIRG2GroupConfigConfigurationType | read-write | mandatory | The group configuration type. |
| 1.3.6.1.4.1.318.1.1.13.4.2.3.3 | ScalarairIRG2GroupConfigCapacityControlType | read-write | mandatory | The group capacity control. |
| 1.3.6.1.4.1.318.1.1.13.4.2.3.4 | ScalarairIRG2GroupConfigFanSpeedControl | read-write | mandatory | The group fan speed control. |
| 1.3.6.1.4.1.318.1.1.13.4.2.3.5 | ScalarairIRG2GroupConfigCoolGainP | read-write | mandatory | The gain component of the PID in hundredths. |
| 1.3.6.1.4.1.318.1.1.13.4.2.3.6 | ScalarairIRG2GroupConfigCoolResetRateI | read-write | mandatory | The integral component of the PID in hundredths. |
| 1.3.6.1.4.1.318.1.1.13.4.2.3.7 | ScalarairIRG2GroupConfigCoolDerivativeD | read-write | mandatory | The derivative component of the PID in hundredths. |
| 1.3.6.1.4.1.318.1.1.13.4.2.3.8 | ScalarairIRG2GroupConfigCoolPIDReset | read-write | mandatory | Will reset the PID coefficients back to the factory defaults. |
| 1.3.6.1.4.1.318.1.1.13.4.2.3.9 | ScalarairIRG2GroupConfigNumberofBackupUnits | read-write | mandatory | The number of backup units. |
| 1.3.6.1.4.1.318.1.1.13.4.2.3.10 | ScalarairIRG2GroupConfigRuntimeBalancingEnable | read-write | mandatory | Enable or disable runtime balancing feature. |
| 1.3.6.1.4.1.318.1.1.13.4.2.3.11 | ScalarairIRG2GroupConfigLoadAssistEnable | read-write | mandatory | Enable or disable load assist feature. |
| 1.3.6.1.4.1.318.1.1.13.4.2.3.12 | ScalarairIRG2GroupConfigNumberOfActiveFlowControllers | read-write | mandatory | The number of active flow controllers present in the group. |
| 1.3.6.1.4.1.318.1.1.13.4.2.3.13 | ScalarairIRG2GroupConfigActiveFlowControllerLampTest | read-write | mandatory | Turns off/on the active flow controller lamp test. |
| 1.3.6.1.4.1.318.1.1.13.4.2.3.14 | ScalarairIRG2GroupConfigAltitudeUS | read-write | mandatory | The group altitude of the units above sea level in feet. |
| 1.3.6.1.4.1.318.1.1.13.4.2.3.15 | ScalarairIRG2GroupConfigAltitudeMetric | read-write | mandatory | The group altitude of the units above sea level in meters. |
| 1.3.6.1.4.1.318.1.1.13.4.3 | NodeairIRG2Alarms | |||
| 1.3.6.1.4.1.318.1.1.13.4.3.1 | ScalarairIRG2AlarmsTableSize | read-only | mandatory | The number of active alarms in the airIRG2AlarmsTable. |
| 1.3.6.1.4.1.318.1.1.13.4.3.2 | TableairIRG2AlarmsTable | not-accessible | mandatory | Table of active alarms for the device. |
| 1.3.6.1.4.1.318.1.1.13.4.3.2.1 | RowairIRG2AlarmsEntry | not-accessible | mandatory | Alarms specification |
| 1.3.6.1.4.1.318.1.1.13.4.3.2.1.1 | ColumnairIRG2AlarmsIndex | read-only | mandatory | Alarm index. |
| 1.3.6.1.4.1.318.1.1.13.4.3.2.1.2 | ColumnairIRG2AlarmsEventCode | read-only | mandatory | Code for the alarm. |
| 1.3.6.1.4.1.318.1.1.13.4.3.2.1.3 | ColumnairIRG2AlarmsDescription | read-only | mandatory | Description of the alarm. |
| 1.3.6.1.4.1.318.1.1.13.4.4 | NodeairIRG2RC | |||
| 1.3.6.1.4.1.318.1.1.13.4.5 | NodeairIRG2RD | |||
| 1.3.6.1.4.1.318.1.1.13.4.5.1 | NodeairIRG2RDType1 | |||
| 1.3.6.1.4.1.318.1.1.13.4.5.2 | NodeairIRG2RDType2 | |||
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1 | NodeairIRG2RDT2Status | |||
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.1 | ScalarairIRG2RDT2StatusOperateMode | read-only | mandatory | The cooling unit operating mode. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.2 | ScalarairIRG2RDT2StatusCoolOutput | read-only | mandatory | The unit cooling output in tenths of kilowatts (kW). |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.3 | ScalarairIRG2RDT2StatusCoolDemand | read-only | mandatory | The unit cooling demand in tenths of kilowatts (kW). |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.4 | ScalarairIRG2RDT2StatusAirFlowUS | read-only | mandatory | The unit air flow in cubic feet per minute. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.5 | ScalarairIRG2RDT2StatusAirFlowMetric | read-only | mandatory | The unit air flow in liters per second. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.6 | ScalarairIRG2RDT2StatusRackInletTempUS | read-only | mandatory | The unit rack inlet temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.7 | ScalarairIRG2RDT2StatusRackInletTempMetric | read-only | mandatory | The unit rack inlet temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.8 | ScalarairIRG2RDT2StatusSupplyAirTempUS | read-only | mandatory | The unit supply air temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.9 | ScalarairIRG2RDT2StatusSupplyAirTempMetric | read-only | mandatory | The unit supply air temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.10 | ScalarairIRG2RDT2StatusReturnAirTempUS | read-only | mandatory | The unit return air temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.11 | ScalarairIRG2RDT2StatusReturnAirTempMetric | read-only | mandatory | The unit return air temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.12 | ScalarairIRG2RDT2StatusSuctionTempUS | read-only | mandatory | The unit suction temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.13 | ScalarairIRG2RDT2StatusSuctionTempMetric | read-only | mandatory | The unit suction temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.14 | ScalarairIRG2RDT2StatusSuperheatTempUS | read-only | mandatory | The unit superheat temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.15 | ScalarairIRG2RDT2StatusSuperheatTempMetric | read-only | mandatory | The unit superheat temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.16 | ScalarairIRG2RDT2StatusFilterDPUS | read-only | mandatory | The unit air filter differential pressure in hundredths of inches of water. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.17 | ScalarairIRG2RDT2StatusFilterDPMetric | read-only | mandatory | The unit air filter differential pressure in pascals (Pa). |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.18 | ScalarairIRG2RDT2StatusSuctionPressureUS | read-only | mandatory | Unit suction pressure in pounds per square inch (PSI). |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.19 | ScalarairIRG2RDT2StatusSuctionPressureMetric | read-only | mandatory | Unit suction pressure in kiloPascals (kPa). |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.20 | ScalarairIRG2RDT2StatusDischargePressureUS | read-only | mandatory | Unit discharge pressure in pounds per square inch (PSI). |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.21 | ScalarairIRG2RDT2StatusDischargePressureMetric | read-only | mandatory | Unit discharge pressure in kiloPascals (kPa). |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.22 | ScalarairIRG2RDT2StatusEvaporatorFanSpeed | read-only | mandatory | The unit average evaporator fan speed in tenths of percent. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.23 | ScalarairIRG2RDT2StatusInputState | read-only | mandatory | The state of the input contact. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.24 | ScalarairIRG2RDT2StatusOutputState | read-only | mandatory | The state of the output relay. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.25 | ScalarairIRG2RDT2StatusOHEInputState | read-only | mandatory | The state of the outside heat exchanger(OHE) input contact. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.26 | ScalarairIRG2RDT2StatusOHEOutputState | read-only | mandatory | The state of the outside heat exchanger(OHE) output relay. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.27 | ScalarairIRG2RDT2StatusCompressor | read-only | mandatory | The state (off/on) of the compressor. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.28 | ScalarairIRG2RDT2StatusFluidValvePos | read-only | mandatory | The position of the fluid valve in percent. This OID is only valid when airIRG2RDT2ConfigUnitType indicates fluidCooled(1). |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.29 | ScalarairIRG2RDT2StatusHotGasBypassValvePos | read-only | mandatory | The position of the hot gas bypass valve in hundredths of percent. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.1.30 | ScalarairIRG2RDT2StatusLeakSensor | read-only | mandatory | The state (no-leak/leak) of the leak sensor. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.2 | NodeairIRG2RDT2RunHours | |||
| 1.3.6.1.4.1.318.1.1.13.4.5.2.2.1 | ScalarairIRG2RDT2RunHoursAirFilter | read-only | mandatory | Unit air filter run hours. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.2.2 | ScalarairIRG2RDT2RunHoursCondensatePump | read-only | mandatory | Unit condensate pump run hours. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.2.3 | ScalarairIRG2RDT2RunHoursCompressor | read-only | mandatory | Unit compressor run hours. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.2.4 | ScalarairIRG2RDT2RunHoursFanPSTableSize | read-only | mandatory | The number of entries in the run hour fan power supply table (airIRG2RDT2RunHoursFanPSTable). |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.2.5 | TableairIRG2RDT2RunHoursFanPSTable | not-accessible | mandatory | Allows for getting run hour information from each power supply. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.2.5.1 | RowairIRG2RDT2RunHoursFanPSEntry | not-accessible | mandatory | The run hours fan power supply table entry. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.2.5.1.1 | ColumnairIRG2RDT2RunHoursFanPSIndex | read-only | mandatory | Index of run hours fan power supply table. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.2.5.1.2 | ColumnairIRG2RDT2RunHoursFanPSHours | read-only | mandatory | Fan power supply run time in hours. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.2.5.1.3 | ColumnairIRG2RDT2RunHoursFanPSPosition | read-only | mandatory | Position of fan power supply within the unit. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.2.6 | ScalarairIRG2RDT2RunHoursEvapFanTableSize | read-only | mandatory | The number of entries in the run hour evaporator fan table (airIRG2RDT2RunHoursEvapFanTable). |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.2.7 | TableairIRG2RDT2RunHoursEvapFanTable | not-accessible | mandatory | Allows for getting information from each evaporator fan run hour in the system. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.2.7.1 | RowairIRG2RDT2RunHoursEvapFanEntry | not-accessible | mandatory | Allows for getting information from each evaporator fan run hour in the system. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.2.7.1.1 | ColumnairIRG2RDT2RunHoursEvapFanIndex | read-only | mandatory | Index of run hours evaporator fan table. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.2.7.1.2 | ColumnairIRG2RDT2RunHoursEvapFanHours | read-only | mandatory | Evaporator fan run time in hours. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.2.8 | ScalarairIRG2RDT2RunHoursUnit | read-only | mandatory | Unit run time in hours. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.3 | NodeairIRG2RDT2ServiceIntervals | |||
| 1.3.6.1.4.1.318.1.1.13.4.5.2.3.1 | ScalarairIRG2RDT2ServiceIntervalsAirFilter | read-write | mandatory | Air filter service interval in weeks. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.3.2 | ScalarairIRG2RDT2ServiceIntervalsAirFilterAlarm | read-write | mandatory | The air filter service interval alarm enable/disable. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.4 | NodeairIRG2RDT2Thresholds | |||
| 1.3.6.1.4.1.318.1.1.13.4.5.2.4.1 | ScalarairIRG2RDT2ThresholdsRackInletHighTempUS | read-write | mandatory | Unit rack inlet air high temperature threshold in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.4.2 | ScalarairIRG2RDT2ThresholdsRackInletHighTempMetric | read-write | mandatory | Unit rack inlet air high temperature threshold in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.4.3 | ScalarairIRG2RDT2ThresholdsSupplyAirHighTempUS | read-write | mandatory | Unit supply air high temperature threshold in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.4.4 | ScalarairIRG2RDT2ThresholdsSupplyAirHighTempMetric | read-write | mandatory | Unit supply air high temperature threshold in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.4.5 | ScalarairIRG2RDT2ThresholdsReturnAirHighTempUS | read-write | mandatory | Unit return air high temperature threshold in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.4.6 | ScalarairIRG2RDT2ThresholdsReturnAirHighTempMetric | read-write | mandatory | Unit return air high temperature threshold in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.5 | NodeairIRG2RDT2Setpoints | |||
| 1.3.6.1.4.1.318.1.1.13.4.5.2.6 | NodeairIRG2RDT2Config | |||
| 1.3.6.1.4.1.318.1.1.13.4.5.2.6.1 | ScalarairIRG2RDT2ConfigUnitType | read-only | mandatory | The type of the unit. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.6.2 | ScalarairIRG2RDT2ConfigStartupDelay | read-write | mandatory | The startup delay in seconds. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.6.3 | ScalarairIRG2RDT2ConfigIdleOnLeakDetect | read-write | mandatory | The idle on leak options setting. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.6.4 | ScalarairIRG2RDT2ConfigInputNormalState | read-write | mandatory | The normal state of the input contact. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.6.5 | ScalarairIRG2RDT2ConfigOutputNormalState | read-write | mandatory | The normal state of the output relay. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.6.6 | ScalarairIRG2RDT2ConfigOutputSource | read-write | mandatory | The source of output relay change. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.6.7 | ScalarairIRG2RDT2ConfigOHEInputNormalState | read-write | mandatory | The normal state of the outside heat exchanger(OHE) input relay. |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.6.8 | ScalarairIRG2RDT2ConfigUnitRoleOverride | read-write | mandatory | When this OID value is (1) automatic, the system determines which units are used as primary units and which units are used as backups. When this OID value is (… |
| 1.3.6.1.4.1.318.1.1.13.4.5.2.6.9 | ScalarairIRG2RDT2ConfigUnitIdleOnCoolFail | read-write | mandatory | When this OID value is (2) yes, the unit idles if it detects that it is blowing warm air into the cold aisle. The unit will attempt to restart at 5 minute inte… |
| 1.3.6.1.4.1.318.1.1.13.4.6 | NodeairIRG2SC | |||
| 1.3.6.1.4.1.318.1.1.13.4.7 | NodeairIRG2RA | |||
| 1.3.6.1.4.1.318.1.1.13.5 | NodeairInRoom | |||
| 1.3.6.1.4.1.318.1.1.13.5.1 | NodeairIRmIdent | |||
| 1.3.6.1.4.1.318.1.1.13.5.1.1 | ScalarairIRmIdentName | read-write | mandatory | A character string identifying the unit name. |
| 1.3.6.1.4.1.318.1.1.13.5.1.2 | ScalarairIRmIdentLocation | read-write | mandatory | A character string identifying the unit location. |
| 1.3.6.1.4.1.318.1.1.13.5.1.3 | ScalarairIRmIdentModelNumber | read-only | mandatory | A character string identifying the unit model number. |
| 1.3.6.1.4.1.318.1.1.13.5.1.4 | ScalarairIRmIdentSerialNumber | read-only | mandatory | A character string identifying the unit serial number. |
| 1.3.6.1.4.1.318.1.1.13.5.1.5 | ScalarairIRmIdentFirmwareRevision | read-only | mandatory | A character string identifying the unit firmware version. |
| 1.3.6.1.4.1.318.1.1.13.5.1.6 | ScalarairIRmIdentHardwareRevision | read-only | mandatory | A character string identifying the unit controller hardware revision. |
| 1.3.6.1.4.1.318.1.1.13.5.1.7 | ScalarairIRmIdentManufactureDate | read-only | mandatory | A character string identifying the unit manufacture date. |
| 1.3.6.1.4.1.318.1.1.13.5.1.8 | ScalarairIRmIdentSysOID | read-only | mandatory | This OID contains an OID path to the device's top level data. |
| 1.3.6.1.4.1.318.1.1.13.5.2 | NodeairIRmAlarms | |||
| 1.3.6.1.4.1.318.1.1.13.5.2.1 | ScalarairIRmAlarmsTableSize | read-only | mandatory | The number of active alarms in the airIRG2AlarmsTable. |
| 1.3.6.1.4.1.318.1.1.13.5.2.2 | TableairIRmAlarmsTable | not-accessible | mandatory | Table of active alarms for the device. |
| 1.3.6.1.4.1.318.1.1.13.5.2.2.1 | RowairIRmAlarmsEntry | not-accessible | mandatory | Alarms specification |
| 1.3.6.1.4.1.318.1.1.13.5.2.2.1.1 | ColumnairIRmAlarmsIndex | read-only | mandatory | Alarm index. |
| 1.3.6.1.4.1.318.1.1.13.5.2.2.1.2 | ColumnairIRmAlarmsEventCode | read-only | mandatory | Code for the alarm. |
| 1.3.6.1.4.1.318.1.1.13.5.2.2.1.3 | ColumnairIRmAlarmsDescription | read-only | mandatory | Description of the alarm. |
| 1.3.6.1.4.1.318.1.1.13.5.3 | NodeairIRmPerimeter | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.2 | NodeairIRmPmCommon1 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.2.1 | ScalarairIRmPmUnitType | read-only | mandatory | Unit type (1). |
| 1.3.6.1.4.1.318.1.1.13.5.3.2.3 | ScalarairIRmPmSwVersion | read-only | mandatory | Software version (3). |
| 1.3.6.1.4.1.318.1.1.13.5.3.2.5 | ScalarairIRmPmBusAddress | read-only | mandatory | Bus addresss of unit (5). |
| 1.3.6.1.4.1.318.1.1.13.5.3.2.7 | ScalarairIRmPmControllerType | read-only | mandatory | Controller type (7). |
| 1.3.6.1.4.1.318.1.1.13.5.3.2.8 | ScalarairIRmPmGeneralError | read-only | mandatory | General Error (8) |
| 1.3.6.1.4.1.318.1.1.13.5.3.2.9 | ScalarairIRmPmErrorOnBus | read-only | mandatory | Error On Bus (9) |
| 1.3.6.1.4.1.318.1.1.13.5.3.3 | NodeairIRmPmCommon2 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.3.1 | ScalarairIRmPmPCStop | read-only | mandatory | PC-STOP (1000) |
| 1.3.6.1.4.1.318.1.1.13.5.3.3.2 | ScalarairIRmPmRemoteStop | read-only | mandatory | Remote Stop (1001) |
| 1.3.6.1.4.1.318.1.1.13.5.3.3.3 | ScalarairIRmPmLocalStop | read-only | mandatory | Local Stop (1002) |
| 1.3.6.1.4.1.318.1.1.13.5.3.3.4 | ScalarairIRmPmTimerStop | read-only | mandatory | Timer Stop (1003) |
| 1.3.6.1.4.1.318.1.1.13.5.3.3.5 | ScalarairIRmPmSeqStop | read-only | mandatory | Seq. Stop (1004) |
| 1.3.6.1.4.1.318.1.1.13.5.3.3.7 | ScalarairIRmPmRemoteUPS | read-only | mandatory | Remote UPS (1006) |
| 1.3.6.1.4.1.318.1.1.13.5.3.3.8 | ScalarairIRmPmLocalUPS | read-only | mandatory | Local UPS (1007) |
| 1.3.6.1.4.1.318.1.1.13.5.3.3.11 | ScalarairIRmPmCommonAlarm | read-only | mandatory | Common alarm (1010). |
| 1.3.6.1.4.1.318.1.1.13.5.3.3.12 | ScalarairIRmPmResetAllAlarms | read-write | mandatory | Reset all alarms control (1011). |
| 1.3.6.1.4.1.318.1.1.13.5.3.3.14 | ScalarairIRmPmUnitOnOff | read-only | mandatory | Unit running state (1013). |
| 1.3.6.1.4.1.318.1.1.13.5.3.3.15 | ScalarairIRmPmMaintenance | read-only | mandatory | Maintenance necessary state (1014). |
| 1.3.6.1.4.1.318.1.1.13.5.3.3.23 | ScalarairIRmPmUnitTemperatureScale | read-only | mandatory | Current Unit Temperature Scale (1022). |
| 1.3.6.1.4.1.318.1.1.13.5.3.3.24 | ScalarairIRmPmUnitWinterMode | read-only | mandatory | Winter or summer configuration mode (1023). |
| 1.3.6.1.4.1.318.1.1.13.5.3.3.25 | ScalarairIRmPmDayNightMode | read-only | mandatory | Day or night configuration mode (1024). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4 | NodeairIRmPmCommon3 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.4.1 | ScalarairIRmPmLastMaintenanceYear | read-only | mandatory | Last maintenance year (1160). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.2 | ScalarairIRmPmLastMaintenanceMonth | read-only | mandatory | Last maintenance month (1161). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.3 | ScalarairIRmPmLastMaintenanceDay | read-only | mandatory | Last maintenance day (1162). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.4 | ScalarairIRmPmUnitMaintenanceInterval | read-only | mandatory | Unit maintenance interval in months (1163). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.5 | ScalarairIRmPmRuntimeUnit | read-only | mandatory | Runtime unit in hours (1164). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.6 | ScalarairIRmPmStoptimeUnit | read-only | mandatory | Unit stoptime in hours (1165) |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.7 | ScalarairIRmPmRuntimeCooling | read-only | mandatory | Cooling runtime in hours (1166) |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.8 | ScalarairIRmPmRuntimeHeating | read-only | mandatory | Heating runtime in hours (1167) |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.9 | ScalarairIRmPmRuntimeHumidification | read-only | mandatory | Humidification runtime in hours (1168) |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.10 | ScalarairIRmPmRuntimeDehumidification | read-only | mandatory | Dehumidification runtime in hours (1169) |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.11 | NodeairIRmPmUnitTemperature | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.4.11.1 | ScalarairIRmPmUnitTemperatureC | read-only | mandatory | Unit temperature in tenths of degrees Celsius (1170). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.11.2 | ScalarairIRmPmUnitTemperatureF | read-only | mandatory | Unit temperature in tenths of degrees Fahrenheit (1170). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.12 | ScalarairIRmPmUnitHumidity | read-only | mandatory | Unit humidity in tenths of %RH (1171). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.14 | NodeairIRmPmSetpointTemperatureDay | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.4.14.1 | ScalarairIRmPmSetpointTemperatureDayC | read-write | mandatory | Setpoint daytime temperature in tenths of degrees Celsius (1173). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.14.2 | ScalarairIRmPmSetpointTemperatureDayF | read-write | mandatory | Setpoint daytime temperature in tenths of degrees Fahrenheit (1173). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.15 | NodeairIRmPmSetpointTemperatureNight | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.4.15.1 | ScalarairIRmPmSetpointTemperatureNightC | read-write | mandatory | Setpoint nighttime temperature in tenths of degrees Celsius (1174). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.15.2 | ScalarairIRmPmSetpointTemperatureNightF | read-write | mandatory | Setpoint nighttime temperature in tenths of degrees Fahrenheit (1174). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.17 | ScalarairIRmPmSetpointHumidity | read-write | mandatory | Setpoint humidity in tenths of %RH (1176). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.24 | ScalarairIRmPmUnitControlType | read-only | mandatory | Current unit control type (1183). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.29 | NodeairIRmPmWinterModeStartTemp | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.4.29.1 | ScalarairIRmPmWinterModeStartTempC | read-only | mandatory | Winter mode start temperature in tenths of degrees Celsius (1188). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.29.2 | ScalarairIRmPmWinterModeStartTempF | read-only | mandatory | Winter mode start temperature in tenths of degrees Fahrenheit (1188). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.30 | NodeairIRmPmWinterModeHysteresis | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.4.30.1 | ScalarairIRmPmWinterModeHysteresisK | read-only | mandatory | Winter mode hysteresis in tenths of Kelvins (1189) |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.30.2 | ScalarairIRmPmWinterModeHysteresisF | read-only | mandatory | Winter mode hysteresis in tenths of degrees Fahrenheit (1189) |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.32 | NodeairIRmPmWaterTemperature | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.4.32.1 | ScalarairIRmPmWaterTemperatureC | read-only | mandatory | Water temperature in tenths of degrees Celsius (1191). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.32.2 | ScalarairIRmPmWaterTemperatureF | read-only | mandatory | Water temperature in tenths of degrees Fahrenheit (1191). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.33 | NodeairIRmPmReturnAirTemperature | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.4.33.1 | ScalarairIRmPmReturnAirTemperatureC | read-only | mandatory | Return air temperature in tenths of degrees Celsius (1192). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.33.2 | ScalarairIRmPmReturnAirTemperatureF | read-only | mandatory | Return air temperature in tenths of degrees Fahrenheit (1192). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.34 | NodeairIRmPmSupplyAirTemperature | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.4.34.1 | ScalarairIRmPmSupplyAirTemperatureC | read-only | mandatory | Supply air temperature in tenths of degrees Celsius (1193). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.34.2 | ScalarairIRmPmSupplyAirTemperatureF | read-only | mandatory | Supply air temperature in tenths of degrees Fahrenheit (1193). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.35 | ScalarairIRmPmReturnAirHumidity | read-only | mandatory | Return air humidity in tenths of %RH (1194). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.36 | ScalarairIRmPmSupplyAirHumidity | read-only | mandatory | Supply air humidity in tenths of %RH (1195). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.37 | NodeairIRmPmOutsideAirTemperature | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.4.37.1 | ScalarairIRmPmOutsideAirTemperatureC | read-only | mandatory | Outside air temperature in tenths of degrees Celsius (1196) |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.37.2 | ScalarairIRmPmOutsideAirTemperatureF | read-only | mandatory | Outside air temperature in tenths of degrees Fahrenheit (1196) |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.38 | ScalarairIRmPmOutsideAirHumidity | read-only | mandatory | Outside air humidity in tenths of percent relative humidity (1197) |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.39 | ScalarairIRmPmCoolingPriority | read-write | mandatory | Cooling priority (1198). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.43 | NodeairIRmPmWaterTemperature2 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.4.43.1 | ScalarairIRmPmWaterTemperature2C | read-only | mandatory | Water temperature 2 in tenths of degrees Celsius (1202). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.43.2 | ScalarairIRmPmWaterTemperature2F | read-only | mandatory | Water temperature 2 in tenths of degrees Fahrenheit (1202). |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.44 | ScalarairIRmPmRuntimeFreeCooling | read-only | mandatory | Freecooling runtime in hours (1203) |
| 1.3.6.1.4.1.318.1.1.13.5.3.4.45 | ScalarairIRmPmRuntimeMixedModeFreeCooling | read-only | mandatory | Mixed mode freecooling runtime in hours (1203) |
| 1.3.6.1.4.1.318.1.1.13.5.3.5 | NodeairIRmPmCommon4 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.5.4 | ScalarairIRmPmNumberOfCompressors | read-only | mandatory | Number of compressors (1761) |
| 1.3.6.1.4.1.318.1.1.13.5.3.5.5 | ScalarairIRmPmNumberOfSuctionValves | read-only | mandatory | Number of suction valves (1762) |
| 1.3.6.1.4.1.318.1.1.13.5.3.5.6 | ScalarairIRmPmNumberOfDryCoolers | read-only | mandatory | Number of drycoolers (1763) |
| 1.3.6.1.4.1.318.1.1.13.5.3.5.7 | ScalarairIRmPmNumberOfPumps | read-only | mandatory | Number of pumps (1764) |
| 1.3.6.1.4.1.318.1.1.13.5.3.5.8 | ScalarairIRmPmNumberOfElectricHeaters | read-only | mandatory | Number of electric heaters (1765) |
| 1.3.6.1.4.1.318.1.1.13.5.3.5.9 | ScalarairIRmPmNumberOfHumidifiers | read-only | mandatory | Number of humidifiers (1766) |
| 1.3.6.1.4.1.318.1.1.13.5.3.5.10 | ScalarairIRmPmNumberOfFans | read-only | mandatory | Number of fans (1767) |
| 1.3.6.1.4.1.318.1.1.13.5.3.5.11 | ScalarairIRmPmNumberOfLouvers | read-only | mandatory | Number of louvers (1768) |
| 1.3.6.1.4.1.318.1.1.13.5.3.5.12 | ScalarairIRmPmNumberOfSensors | read-only | mandatory | Number of sensors (1769) |
| 1.3.6.1.4.1.318.1.1.13.5.3.5.13 | ScalarairIRmPmNumberOfExternalAlarmInputs | read-only | mandatory | Number of external alarm inputs (1770) |
| 1.3.6.1.4.1.318.1.1.13.5.3.5.14 | ScalarairIRmPmNumberOfGECWValves | read-only | mandatory | Number of GE/CW valves (1771) |
| 1.3.6.1.4.1.318.1.1.13.5.3.5.15 | ScalarairIRmPmNumberOfHotGasReheat | read-only | mandatory | Number of hot gas reheaters (1772) |
| 1.3.6.1.4.1.318.1.1.13.5.3.5.16 | ScalarairIRmPmNumberOfPWWReheat | read-only | mandatory | Number of PWW reheaters (1773) |
| 1.3.6.1.4.1.318.1.1.13.5.3.5.17 | ScalarairIRmPmNumberOfDehumidifiers | read-only | mandatory | Number of dehumidifiers (1774) |
| 1.3.6.1.4.1.318.1.1.13.5.3.6 | NodeairIRmPmCommon5 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.6.1 | NodeairIRmPmUnitEvaporationTemperature1 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.6.1.1 | ScalarairIRmPmUnitEvaporationTemperature1C | read-only | mandatory | Unit evaporation temperature 1 in tenths of degrees Celsius (2232) |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.1.2 | ScalarairIRmPmUnitEvaporationTemperature1F | read-only | mandatory | Unit evaporation temperature 1 in tenths of degrees Fahrenheit (2232) |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.2 | ScalarairIRmPmUnitEvaporationPressure1 | read-only | mandatory | Unit evaporation pressure 1 in tenths of Bars (2233) |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.3 | NodeairIRmPmUnitCondensationTemperature1 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.6.3.1 | ScalarairIRmPmUnitCondensationTemperature1C | read-only | mandatory | Unit condensation temperature 1 in tenths of degrees Celsius (2234) |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.3.2 | ScalarairIRmPmUnitCondensationTemperature1F | read-only | mandatory | Unit condensation temperature 1 in tenths of degrees Fahrenheit (2234) |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.4 | ScalarairIRmPmUnitCondensationPressure1 | read-only | mandatory | Unit condensation pressure 1 in tenths of Bars (2235) |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.8 | NodeairIRmPmMaxLimitReturnAirTemperature | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.6.8.1 | ScalarairIRmPmMaxLimitReturnAirTemperatureC | read-write | mandatory | Maximum limit return air temperature in tenths of degrees Celsius (2239). |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.8.2 | ScalarairIRmPmMaxLimitReturnAirTemperatureF | read-write | mandatory | Maximum limit return air temperature in tenths of degrees Fahrenheit (2239). |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.9 | NodeairIRmPmMinLimitReturnAirTemperature | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.6.9.1 | ScalarairIRmPmMinLimitReturnAirTemperatureC | read-write | mandatory | Minimum limit return air temperature in tenths of degrees Celsius (2240). |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.9.2 | ScalarairIRmPmMinLimitReturnAirTemperatureF | read-write | mandatory | Minimum limit return air temperature in tenths of degrees Fahrenheit (2240). |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.10 | NodeairIRmPmMaxLimitSupplyAirTemperature | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.6.10.1 | ScalarairIRmPmMaxLimitSupplyAirTemperatureC | read-write | mandatory | Maximum limit supply air temperature in tenths of degrees Celsius (2241). |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.10.2 | ScalarairIRmPmMaxLimitSupplyAirTemperatureF | read-write | mandatory | Maximum limit supply air temperature in tenths of degrees Fahrenheit (2241). |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.11 | NodeairIRmPmMinLimitSupplyAirTemperature | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.6.11.1 | ScalarairIRmPmMinLimitSupplyAirTemperatureC | read-write | mandatory | Minimum limit supply air temperature in tenths of degrees Celsius (2242). |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.11.2 | ScalarairIRmPmMinLimitSupplyAirTemperatureF | read-write | mandatory | Minimum limit supply air temperature in tenths of degrees Fahrenheit (2242). |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.12 | NodeairIRmPmMaxLimitWaterTemperature | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.6.12.1 | ScalarairIRmPmMaxLimitWaterTemperatureC | read-write | mandatory | Maximum limit water temperature in tenths of degrees Celsius (2243). |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.12.2 | ScalarairIRmPmMaxLimitWaterTemperatureF | read-write | mandatory | Maximum limit water temperature in tenths of degrees Fahrenheit (2243). |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.13 | NodeairIRmPmMinLimitWaterTemperature | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.6.13.1 | ScalarairIRmPmMinLimitWaterTemperatureC | read-write | mandatory | Minimum limit water temperature in tenths of degrees Celsius (2244). |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.13.2 | ScalarairIRmPmMinLimitWaterTemperatureF | read-write | mandatory | Minimum limit water temperature in tenths of degrees Fahrenheit (2244). |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.14 | ScalarairIRmPmMaxLimitReturnAirHumidity | read-write | mandatory | Maximum limit return air humidity in tenths of %RH (2245). |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.15 | ScalarairIRmPmMinLimitReturnAirHumidity | read-write | mandatory | Minimum limit return air humidity in tenths of %RH (2246). |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.16 | ScalarairIRmPmMaxLimitSupplyAirHumidity | read-write | mandatory | Maximum limit supply air humidity in tenths of %RH (2247). |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.17 | ScalarairIRmPmMinLimitSupplyAirHumidity | read-write | mandatory | Minimum limit supply air humidity in tenths of %RH (2248). |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.18 | ScalarairIRmPmLowPressureWinterDelay | read-only | mandatory | Winter mode low pressure delay in seconds (2249) |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.19 | ScalarairIRmPmUnitCondensationPressure2 | read-only | mandatory | Unit condensation pressure 2 in tenths of Bars (2250) |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.20 | ScalarairIRmPmUnitOverloadSwitch | read-only | mandatory | Unit overload switch setting in tenths of Kelvins (2251) |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.41 | NodeairIRmPmUnitCondensationTemperature2 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.6.41.1 | ScalarairIRmPmUnitCondensationTemperature2C | read-only | mandatory | Unit condensation temperature 2 in tenths of degrees Celsius (2272) |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.41.2 | ScalarairIRmPmUnitCondensationTemperature2F | read-only | mandatory | Unit condensation temperature 2 in tenths of degrees Fahrenheit (2272) |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.42 | ScalarairIRmPmUnitEvaporationPressure2 | read-only | mandatory | Unit evaporation pressure 2 in tenths of Bars (2273) |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.43 | NodeairIRmPmUnitEvaporationTemperature2 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.6.43.1 | ScalarairIRmPmUnitEvaporationTemperature2C | read-only | mandatory | Unit evaporation temperature 2 in tenths of degrees Celsius (2274) |
| 1.3.6.1.4.1.318.1.1.13.5.3.6.43.2 | ScalarairIRmPmUnitEvaporationTemperature2F | read-only | mandatory | Unit evaporation temperature 2 in tenths of degrees Fahrenheit (2274) |
| 1.3.6.1.4.1.318.1.1.13.5.3.7 | NodeairIRmPmCompressor1 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.7.2 | ScalarairIRmPmCmp1ManOperationActive | read-only | mandatory | Compressor 1 manual operation active (4401) |
| 1.3.6.1.4.1.318.1.1.13.5.3.7.3 | ScalarairIRmPmCmp1ManOperationState | read-only | mandatory | Compressor 1 manual operation state (4402) |
| 1.3.6.1.4.1.318.1.1.13.5.3.7.4 | ScalarairIRmPmCmp1Running | read-only | mandatory | Compressor 1 running (4403) |
| 1.3.6.1.4.1.318.1.1.13.5.3.7.17 | NodeairIRmPmCmp1StartTempSummer | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.7.17.1 | ScalarairIRmPmCmp1StartTempSummerK | read-write | mandatory | Compressor 1 summer mode start temperature in tenths of Kelvins (4416) |
| 1.3.6.1.4.1.318.1.1.13.5.3.7.17.2 | ScalarairIRmPmCmp1StartTempSummerF | read-write | mandatory | Compressor 1 summer mode start temperature in tenths of degrees Fahrenheit (4416) |
| 1.3.6.1.4.1.318.1.1.13.5.3.7.18 | NodeairIRmPmCmp1HysteresisSummer | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.7.18.1 | ScalarairIRmPmCmp1HysteresisSummerK | read-write | mandatory | Compressor 1 summer mode hysteresis setting in tenths of Kelvins (4417) |
| 1.3.6.1.4.1.318.1.1.13.5.3.7.18.2 | ScalarairIRmPmCmp1HysteresisSummerF | read-write | mandatory | Compressor 1 summer mode hysteresis setting in tenths of Fahrenheit (4417) |
| 1.3.6.1.4.1.318.1.1.13.5.3.7.19 | NodeairIRmPmCmp1StartTempWinter | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.7.19.1 | ScalarairIRmPmCmp1StartTempWinterK | read-write | mandatory | Compressor 1 winter mode start temperature in tenths of Kelvins (4418) |
| 1.3.6.1.4.1.318.1.1.13.5.3.7.19.2 | ScalarairIRmPmCmp1StartTempWinterF | read-write | mandatory | Compressor 1 winter mode start temperature in tenths of degrees Fahrenheit (4418) |
| 1.3.6.1.4.1.318.1.1.13.5.3.7.20 | NodeairIRmPmCmp1HysteresisWinter | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.7.20.1 | ScalarairIRmPmCmp1HysteresisWinterK | read-write | mandatory | Compressor 1 Winter mode hysteresis setting in tenths of Kelvins (4419) |
| 1.3.6.1.4.1.318.1.1.13.5.3.7.20.2 | ScalarairIRmPmCmp1HysteresisWinterF | read-write | mandatory | Compressor 1 Winter mode hysteresis setting in tenths of Fahrenheit (4419) |
| 1.3.6.1.4.1.318.1.1.13.5.3.7.29 | ScalarairIRmPmCmp1Runtime | read-only | mandatory | Compressor 1 runtime in hours (4428) |
| 1.3.6.1.4.1.318.1.1.13.5.3.8 | NodeairIRmPmCompressor2 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.8.2 | ScalarairIRmPmCmp2ManOperationActive | read-only | mandatory | Compressor 2 manual operation active (4501) |
| 1.3.6.1.4.1.318.1.1.13.5.3.8.3 | ScalarairIRmPmCmp2ManOperationState | read-only | mandatory | Compressor 2 manual operation state (4502) |
| 1.3.6.1.4.1.318.1.1.13.5.3.8.4 | ScalarairIRmPmCmp2Running | read-only | mandatory | Compressor 2 running (4503) |
| 1.3.6.1.4.1.318.1.1.13.5.3.8.17 | NodeairIRmPmCmp2StartTempSummer | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.8.17.1 | ScalarairIRmPmCmp2StartTempSummerK | read-write | mandatory | Compressor 2 summer mode start temperature in tenths of Kelvins (4516) |
| 1.3.6.1.4.1.318.1.1.13.5.3.8.17.2 | ScalarairIRmPmCmp2StartTempSummerF | read-write | mandatory | Compressor 2 summer mode start temperature in tenths of degrees Fahrenheit (4516) |
| 1.3.6.1.4.1.318.1.1.13.5.3.8.18 | NodeairIRmPmCmp2HysteresisSummer | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.8.18.1 | ScalarairIRmPmCmp2HysteresisSummerK | read-write | mandatory | Compressor 2 summer mode hysteresis setting in tenths of Kelvins (4517) |
| 1.3.6.1.4.1.318.1.1.13.5.3.8.18.2 | ScalarairIRmPmCmp2HysteresisSummerF | read-write | mandatory | Compressor 2 summer mode hysteresis setting in tenths of Fahrenheit (4517) |
| 1.3.6.1.4.1.318.1.1.13.5.3.8.19 | NodeairIRmPmCmp2StartTempWinter | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.8.19.1 | ScalarairIRmPmCmp2StartTempWinterK | read-write | mandatory | Compressor 2 winter mode start temperature in tenths of Kelvins (4518) |
| 1.3.6.1.4.1.318.1.1.13.5.3.8.19.2 | ScalarairIRmPmCmp2StartTempWinterF | read-write | mandatory | Compressor 2 winter mode start temperature in tenths of degrees Fahrenheit (4518) |
| 1.3.6.1.4.1.318.1.1.13.5.3.8.20 | NodeairIRmPmCmp2HysteresisWinter | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.8.20.1 | ScalarairIRmPmCmp2HysteresisWinterK | read-write | mandatory | Compressor 2 Winter mode hysteresis setting in tenths of Kelvins (4519) |
| 1.3.6.1.4.1.318.1.1.13.5.3.8.20.2 | ScalarairIRmPmCmp2HysteresisWinterF | read-write | mandatory | Compressor 2 Winter mode hysteresis setting in tenths of Fahrenheit (4519) |
| 1.3.6.1.4.1.318.1.1.13.5.3.8.29 | ScalarairIRmPmCmp2Runtime | read-only | mandatory | Compressor 2 runtime in hours (4528) |
| 1.3.6.1.4.1.318.1.1.13.5.3.9 | NodeairIRmPmSuctionValve1 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.10 | NodeairIRmPmSuctionValve2 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.11 | NodeairIRmPmEheating1 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.11.2 | ScalarairIRmPmEheating1ManOpEnable | read-only | mandatory | Electric heater #1 manual operation enable (4801) |
| 1.3.6.1.4.1.318.1.1.13.5.3.11.4 | ScalarairIRmPmEheating1Running | read-only | mandatory | Electric heater #1 running state (4803) |
| 1.3.6.1.4.1.318.1.1.13.5.3.11.5 | ScalarairIRmPmEheating1ManOpRunning | read-only | mandatory | Electric heater #1 running in manual operation mode (4804) |
| 1.3.6.1.4.1.318.1.1.13.5.3.11.9 | ScalarairIRmPmEheating1Type | read-only | mandatory | Electric heater #1 type (4808) |
| 1.3.6.1.4.1.318.1.1.13.5.3.11.10 | NodeairIRmPmEheating1StartTemperature | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.11.10.1 | ScalarairIRmPmEheating1StartTemperatureK | read-write | mandatory | Electric heater #1 start temperature in tenths of Kelvins (4809) |
| 1.3.6.1.4.1.318.1.1.13.5.3.11.10.2 | ScalarairIRmPmEheating1StartTemperatureF | read-write | mandatory | Electric heater #1 start temperature in tenths of degrees Fahrenheit (4809) |
| 1.3.6.1.4.1.318.1.1.13.5.3.11.11 | NodeairIRmPmEheating1Hysteresis | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.11.11.1 | ScalarairIRmPmEheating1HysteresisK | read-write | mandatory | Electric heater #1 hysteresis in tenths of Kelvins (4810) |
| 1.3.6.1.4.1.318.1.1.13.5.3.11.11.2 | ScalarairIRmPmEheating1HysteresisF | read-write | mandatory | Electric heater #1 hysteresis in tenths of degrees Fahrenheit (4810) |
| 1.3.6.1.4.1.318.1.1.13.5.3.11.17 | ScalarairIRmPmEheating1Runtime | read-only | mandatory | Electric heater #1 runtime in hours (4816) |
| 1.3.6.1.4.1.318.1.1.13.5.3.12 | NodeairIRmPmEheating2 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.12.2 | ScalarairIRmPmEheating2ManOpEnable | read-only | mandatory | Electric heater #2 manual operation enable (4901) |
| 1.3.6.1.4.1.318.1.1.13.5.3.12.4 | ScalarairIRmPmEheating2Running | read-only | mandatory | Electric heater #2 running state (4903) |
| 1.3.6.1.4.1.318.1.1.13.5.3.12.5 | ScalarairIRmPmEheating2ManOpRunning | read-only | mandatory | Electric heater #2 running in manual operation mode (4904) |
| 1.3.6.1.4.1.318.1.1.13.5.3.12.9 | ScalarairIRmPmEheating2Type | read-only | mandatory | Electric heater #2 type (4908) |
| 1.3.6.1.4.1.318.1.1.13.5.3.12.10 | NodeairIRmPmEheating2StartTemperature | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.12.10.1 | ScalarairIRmPmEheating2StartTemperatureK | read-write | mandatory | Electric heater #2 start temperature in tenths of Kelvins (4909) |
| 1.3.6.1.4.1.318.1.1.13.5.3.12.10.2 | ScalarairIRmPmEheating2StartTemperatureF | read-write | mandatory | Electric heater #2 start temperature in tenths of degrees Fahrenheit (4909) |
| 1.3.6.1.4.1.318.1.1.13.5.3.12.11 | NodeairIRmPmEheating2Hysteresis | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.12.11.1 | ScalarairIRmPmEheating2HysteresisK | read-write | mandatory | Electric heater #2 hysteresis in tenths of Kelvins (4910) |
| 1.3.6.1.4.1.318.1.1.13.5.3.12.11.2 | ScalarairIRmPmEheating2HysteresisF | read-write | mandatory | Electric heater #2 hysteresis in tenths of degrees Fahrenheit (4910) |
| 1.3.6.1.4.1.318.1.1.13.5.3.12.17 | ScalarairIRmPmEheating2Runtime | read-only | mandatory | Electric heater #2 runtime in hours (4916) |
| 1.3.6.1.4.1.318.1.1.13.5.3.13 | NodeairIRmPmEheating3 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.13.2 | ScalarairIRmPmEheating3ManOpEnable | read-only | mandatory | Electric heater #3 manual operation enable (5001) |
| 1.3.6.1.4.1.318.1.1.13.5.3.13.4 | ScalarairIRmPmEheating3Running | read-only | mandatory | Electric heater #3 running state (5003) |
| 1.3.6.1.4.1.318.1.1.13.5.3.13.5 | ScalarairIRmPmEheating3ManOpRunning | read-only | mandatory | Electric heater #3 running in manual operation mode (5004) |
| 1.3.6.1.4.1.318.1.1.13.5.3.13.9 | ScalarairIRmPmEheating3Type | read-only | mandatory | Electric heater #3 type (5008) |
| 1.3.6.1.4.1.318.1.1.13.5.3.13.10 | NodeairIRmPmEheating3StartTemperature | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.13.10.1 | ScalarairIRmPmEheating3StartTemperatureK | read-write | mandatory | Electric heater #3 start temperature in tenths of Kelvins (5009) |
| 1.3.6.1.4.1.318.1.1.13.5.3.13.10.2 | ScalarairIRmPmEheating3StartTemperatureF | read-write | mandatory | Electric heater #3 start temperature in tenths of degrees Fahrenheit (5009) |
| 1.3.6.1.4.1.318.1.1.13.5.3.13.11 | NodeairIRmPmEheating3Hysteresis | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.13.11.1 | ScalarairIRmPmEheating3HysteresisK | read-write | mandatory | Electric heater #3 hysteresis in tenths of Kelvins (5010) |
| 1.3.6.1.4.1.318.1.1.13.5.3.13.11.2 | ScalarairIRmPmEheating3HysteresisF | read-write | mandatory | Electric heater #3 hysteresis in tenths of degrees Fahrenheit (5010) |
| 1.3.6.1.4.1.318.1.1.13.5.3.13.17 | ScalarairIRmPmEheating3Runtime | read-only | mandatory | Electric heater #3 runtime in hours (5016) |
| 1.3.6.1.4.1.318.1.1.13.5.3.14 | NodeairIRmPmEheating4 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.14.2 | ScalarairIRmPmEheating4ManOpEnable | read-only | mandatory | Electric heater #4 manual operation enable (5101) |
| 1.3.6.1.4.1.318.1.1.13.5.3.14.4 | ScalarairIRmPmEheating4Running | read-only | mandatory | Electric heater #4 running state (5103) |
| 1.3.6.1.4.1.318.1.1.13.5.3.14.5 | ScalarairIRmPmEheating4ManOpRunning | read-only | mandatory | Electric heater #4 running in manual operation mode (5104) |
| 1.3.6.1.4.1.318.1.1.13.5.3.14.9 | ScalarairIRmPmEheating4Type | read-only | mandatory | Electric heater #4 type (5108) |
| 1.3.6.1.4.1.318.1.1.13.5.3.14.10 | NodeairIRmPmEheating4StartTemperature | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.14.10.1 | ScalarairIRmPmEheating4StartTemperatureK | read-write | mandatory | Electric heater #4 start temperature in tenths of Kelvins (5109) |
| 1.3.6.1.4.1.318.1.1.13.5.3.14.10.2 | ScalarairIRmPmEheating4StartTemperatureF | read-write | mandatory | Electric heater #4 start temperature in tenths of degrees Fahrenheit (5109) |
| 1.3.6.1.4.1.318.1.1.13.5.3.14.11 | NodeairIRmPmEheating4Hysteresis | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.14.11.1 | ScalarairIRmPmEheating4HysteresisK | read-write | mandatory | Electric heater #4 hysteresis in tenths of Kelvins (5110) |
| 1.3.6.1.4.1.318.1.1.13.5.3.14.11.2 | ScalarairIRmPmEheating4HysteresisF | read-write | mandatory | Electric heater #4 hysteresis in tenths of degrees Fahrenheit (5110) |
| 1.3.6.1.4.1.318.1.1.13.5.3.14.17 | ScalarairIRmPmEheating4Runtime | read-only | mandatory | Electric heater #4 runtime in hours (5116) |
| 1.3.6.1.4.1.318.1.1.13.5.3.15 | NodeairIRmPmGECWvalve | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.15.2 | ScalarairIRmPmGECWvalveManOpEnable | read-only | mandatory | GE/CW valve manual operation enable (5201) |
| 1.3.6.1.4.1.318.1.1.13.5.3.15.9 | NodeairIRmPmGECWvalveStartTemperature | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.15.9.1 | ScalarairIRmPmGECWvalveStartTemperatureK | read-write | mandatory | GE/CW valve start temperature in tenths of Kelvins (5208) |
| 1.3.6.1.4.1.318.1.1.13.5.3.15.9.2 | ScalarairIRmPmGECWvalveStartTemperatureF | read-write | mandatory | GE/CW valve start temperature in tenths of degrees Fahrenheit (5208) |
| 1.3.6.1.4.1.318.1.1.13.5.3.15.10 | NodeairIRmPmGECWvalveLinearRange | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.15.10.1 | ScalarairIRmPmGECWvalveLinearRangeK | read-write | mandatory | GE/CW valve linear range in tenths of Kelvins (5209) |
| 1.3.6.1.4.1.318.1.1.13.5.3.15.10.2 | ScalarairIRmPmGECWvalveLinearRangeF | read-write | mandatory | GE/CW valve linear range in tenths of degrees Fahrenheit (5209) |
| 1.3.6.1.4.1.318.1.1.13.5.3.15.12 | NodeairIRmPmGECWvalveGEOffTemp | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.15.12.1 | ScalarairIRmPmGECWvalveGEOffTempC | read-write | mandatory | GE/CW valve GE off temperature in tenths of degrees Celsius (5211) |
| 1.3.6.1.4.1.318.1.1.13.5.3.15.12.2 | ScalarairIRmPmGECWvalveGEOffTempF | read-write | mandatory | GE/CW valve GE off temperature in tenths of degrees Fahrenheit (5211) |
| 1.3.6.1.4.1.318.1.1.13.5.3.15.15 | ScalarairIRmPmGECWvalveOpeningGrade | read-only | mandatory | GE/CW valve opening grade in percent (5214) |
| 1.3.6.1.4.1.318.1.1.13.5.3.15.16 | ScalarairIRmPmGECWvalveManOpOpeningGrade | read-only | mandatory | GE/CW valve manual operation opening grade in percent (5215) |
| 1.3.6.1.4.1.318.1.1.13.5.3.16 | NodeairIRmPmGvalve | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.16.2 | ScalarairIRmPmGvalveManOperationEnable | read-only | mandatory | G-valve manual operation enable (5301) |
| 1.3.6.1.4.1.318.1.1.13.5.3.16.11 | ScalarairIRmPmGvalvePreOpeningTime | read-only | mandatory | G-valve pre-opening time in seconds (5310) |
| 1.3.6.1.4.1.318.1.1.13.5.3.16.12 | ScalarairIRmPmGvalvePreOpeningGrade | read-only | mandatory | G-valve pre-opening grade in percent (5311) |
| 1.3.6.1.4.1.318.1.1.13.5.3.16.13 | ScalarairIRmPmGvalveOpeningGrade | read-only | mandatory | G-valve opening grade in percent (5312) |
| 1.3.6.1.4.1.318.1.1.13.5.3.16.14 | ScalarairIRmPmGvalveManOpOpeningGrade | read-only | mandatory | G-valve manual operation opening grade in percent (5313) |
| 1.3.6.1.4.1.318.1.1.13.5.3.17 | NodeairIRmPmDrycooler1 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.17.2 | ScalarairIRmPmDrycooler1ManOpEnable | read-only | mandatory | Drycooler 1 manual operation enable setting (5401) |
| 1.3.6.1.4.1.318.1.1.13.5.3.17.3 | ScalarairIRmPmDrycooler1Running | read-only | mandatory | Drycooler 1 running (5402) |
| 1.3.6.1.4.1.318.1.1.13.5.3.17.5 | ScalarairIRmPmDrycooler1ManOpRunning | read-only | mandatory | Drycooler 1 manual operation running (5404) |
| 1.3.6.1.4.1.318.1.1.13.5.3.17.9 | NodeairIRmPmDrycooler1WinterStartTemp | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.17.9.1 | ScalarairIRmPmDrycooler1WinterStartTempC | read-write | mandatory | Drycooler 1 winter mode start temperature in tenths of degrees Celsius (5408) |
| 1.3.6.1.4.1.318.1.1.13.5.3.17.9.2 | ScalarairIRmPmDrycooler1WinterStartTempF | read-write | mandatory | Drycooler 1 winter mode start temperature in tenths of degrees Fahrenheit (5408) |
| 1.3.6.1.4.1.318.1.1.13.5.3.17.10 | NodeairIRmPmDrycooler1SummerStartTemp | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.17.10.1 | ScalarairIRmPmDrycooler1SummerStartTempC | read-write | mandatory | Drycooler 1 summer mode start temperature in tenths of degrees Celsius (5409) |
| 1.3.6.1.4.1.318.1.1.13.5.3.17.10.2 | ScalarairIRmPmDrycooler1SummerStartTempF | read-write | mandatory | Drycooler 1 summer mode start temperature in tenths of degrees Fahrenheit (5409) |
| 1.3.6.1.4.1.318.1.1.13.5.3.17.11 | NodeairIRmPmDrycooler1Hysteresis | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.17.11.1 | ScalarairIRmPmDrycooler1HysteresisK | read-write | mandatory | Drycooler 1 hysteresis in tenths of Kelvins (5410) |
| 1.3.6.1.4.1.318.1.1.13.5.3.17.11.2 | ScalarairIRmPmDrycooler1HysteresisF | read-write | mandatory | Drycooler 1 hysteresis in tenths of degrees Fahrenheit (5410) |
| 1.3.6.1.4.1.318.1.1.13.5.3.17.16 | ScalarairIRmPmDrycooler1Runtime | read-only | mandatory | Drycooler 1 runtime in hours (5415) |
| 1.3.6.1.4.1.318.1.1.13.5.3.18 | NodeairIRmPmDrycooler2 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.18.2 | ScalarairIRmPmDrycooler2ManOpEnable | read-only | mandatory | Drycooler 2 manual operation enable setting (5501) |
| 1.3.6.1.4.1.318.1.1.13.5.3.18.3 | ScalarairIRmPmDrycooler2Running | read-only | mandatory | Drycooler 2 running (5502) |
| 1.3.6.1.4.1.318.1.1.13.5.3.18.5 | ScalarairIRmPmDrycooler2ManOpRunning | read-only | mandatory | Drycooler 2 manual operation running (5504) |
| 1.3.6.1.4.1.318.1.1.13.5.3.18.9 | NodeairIRmPmDrycooler2WinterStartTemp | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.18.9.1 | ScalarairIRmPmDrycooler2WinterStartTempC | read-write | mandatory | Drycooler 2 winter mode start temperature in tenths of degrees Celsius (5508) |
| 1.3.6.1.4.1.318.1.1.13.5.3.18.9.2 | ScalarairIRmPmDrycooler2WinterStartTempF | read-write | mandatory | Drycooler 2 winter mode start temperature in tenths of degrees Fahrenheit (5508) |
| 1.3.6.1.4.1.318.1.1.13.5.3.18.10 | NodeairIRmPmDrycooler2SummerStartTemp | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.18.10.1 | ScalarairIRmPmDrycooler2SummerStartTempC | read-write | mandatory | Drycooler 2 summer mode start temperature in tenths of degrees Celsius (5509) |
| 1.3.6.1.4.1.318.1.1.13.5.3.18.10.2 | ScalarairIRmPmDrycooler2SummerStartTempF | read-write | mandatory | Drycooler 2 summer mode start temperature in tenths of degrees Fahrenheit (5509) |
| 1.3.6.1.4.1.318.1.1.13.5.3.18.11 | NodeairIRmPmDrycooler2Hysteresis | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.18.11.1 | ScalarairIRmPmDrycooler2HysteresisK | read-write | mandatory | Drycooler 2 hysteresis in tenths of Kelvins (5510) |
| 1.3.6.1.4.1.318.1.1.13.5.3.18.11.2 | ScalarairIRmPmDrycooler2HysteresisF | read-write | mandatory | Drycooler 2 hysteresis in tenths of degrees Fahrenheit (5510) |
| 1.3.6.1.4.1.318.1.1.13.5.3.18.16 | ScalarairIRmPmDrycooler2Runtime | read-only | mandatory | Drycooler 2 runtime in hours (5515) |
| 1.3.6.1.4.1.318.1.1.13.5.3.19 | NodeairIRmPmDrycooler3 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.19.2 | ScalarairIRmPmDrycooler3ManOpEnable | read-only | mandatory | Drycooler 3 manual operation enable setting (5601) |
| 1.3.6.1.4.1.318.1.1.13.5.3.19.3 | ScalarairIRmPmDrycooler3Running | read-only | mandatory | Drycooler 3 running (5602) |
| 1.3.6.1.4.1.318.1.1.13.5.3.19.5 | ScalarairIRmPmDrycooler3ManOpRunning | read-only | mandatory | Drycooler 3 manual operation running (5604) |
| 1.3.6.1.4.1.318.1.1.13.5.3.19.9 | NodeairIRmPmDrycooler3WinterStartTemp | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.19.9.1 | ScalarairIRmPmDrycooler3WinterStartTempC | read-write | mandatory | Drycooler 3 winter mode start temperature in tenths of degrees Celsius (5608) |
| 1.3.6.1.4.1.318.1.1.13.5.3.19.9.2 | ScalarairIRmPmDrycooler3WinterStartTempF | read-write | mandatory | Drycooler 3 winter mode start temperature in tenths of degrees Fahrenheit (5608) |
| 1.3.6.1.4.1.318.1.1.13.5.3.19.10 | NodeairIRmPmDrycooler3SummerStartTemp | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.19.10.1 | ScalarairIRmPmDrycooler3SummerStartTempC | read-write | mandatory | Drycooler 3 summer mode start temperature in tenths of degrees Celsius (5609) |
| 1.3.6.1.4.1.318.1.1.13.5.3.19.10.2 | ScalarairIRmPmDrycooler3SummerStartTempF | read-write | mandatory | Drycooler 3 summer mode start temperature in tenths of degrees Fahrenheit (5609) |
| 1.3.6.1.4.1.318.1.1.13.5.3.19.11 | NodeairIRmPmDrycooler3Hysteresis | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.19.11.1 | ScalarairIRmPmDrycooler3HysteresisK | read-write | mandatory | Drycooler 3 hysteresis in tenths of Kelvins (5610) |
| 1.3.6.1.4.1.318.1.1.13.5.3.19.11.2 | ScalarairIRmPmDrycooler3HysteresisF | read-write | mandatory | Drycooler 3 hysteresis in tenths of degrees Fahrenheit (5610) |
| 1.3.6.1.4.1.318.1.1.13.5.3.19.16 | ScalarairIRmPmDrycooler3Runtime | read-only | mandatory | Drycooler 3 runtime in hours (5615) |
| 1.3.6.1.4.1.318.1.1.13.5.3.20 | NodeairIRmPmDrycooler4 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.20.2 | ScalarairIRmPmDrycooler4ManOpEnable | read-only | mandatory | Drycooler 4 manual operation enable setting (5701) |
| 1.3.6.1.4.1.318.1.1.13.5.3.20.3 | ScalarairIRmPmDrycooler4Running | read-only | mandatory | Drycooler 4 running (5702) |
| 1.3.6.1.4.1.318.1.1.13.5.3.20.5 | ScalarairIRmPmDrycooler4ManOpRunning | read-only | mandatory | Drycooler 4 manual operation running (5704) |
| 1.3.6.1.4.1.318.1.1.13.5.3.20.9 | NodeairIRmPmDrycooler4WinterStartTemp | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.20.9.1 | ScalarairIRmPmDrycooler4WinterStartTempC | read-write | mandatory | Drycooler 4 winter mode start temperature in tenths of degrees Celsius (5708) |
| 1.3.6.1.4.1.318.1.1.13.5.3.20.9.2 | ScalarairIRmPmDrycooler4WinterStartTempF | read-write | mandatory | Drycooler 4 winter mode start temperature in tenths of degrees Fahrenheit (5708) |
| 1.3.6.1.4.1.318.1.1.13.5.3.20.10 | NodeairIRmPmDrycooler4SummerStartTemp | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.20.10.1 | ScalarairIRmPmDrycooler4SummerStartTempC | read-write | mandatory | Drycooler 4 summer mode start temperature in tenths of degrees Celsius (5709) |
| 1.3.6.1.4.1.318.1.1.13.5.3.20.10.2 | ScalarairIRmPmDrycooler4SummerStartTempF | read-write | mandatory | Drycooler 4 summer mode start temperature in tenths of degrees Fahrenheit (5709) |
| 1.3.6.1.4.1.318.1.1.13.5.3.20.11 | NodeairIRmPmDrycooler4Hysteresis | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.20.11.1 | ScalarairIRmPmDrycooler4HysteresisK | read-write | mandatory | Drycooler 4 hysteresis in tenths of Kelvins (5710) |
| 1.3.6.1.4.1.318.1.1.13.5.3.20.11.2 | ScalarairIRmPmDrycooler4HysteresisF | read-write | mandatory | Drycooler 4 hysteresis in tenths of degrees Fahrenheit (5710) |
| 1.3.6.1.4.1.318.1.1.13.5.3.20.16 | ScalarairIRmPmDrycooler4Runtime | read-only | mandatory | Drycooler 4 runtime in hours (5715) |
| 1.3.6.1.4.1.318.1.1.13.5.3.21 | NodeairIRmPmPump1 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.21.2 | ScalarairIRmPmPump1ManOpEnable | read-only | mandatory | Pump 1 manual operation enable state (5801) |
| 1.3.6.1.4.1.318.1.1.13.5.3.21.3 | ScalarairIRmPmPump1Running | read-only | mandatory | Pump 1 running (5802) |
| 1.3.6.1.4.1.318.1.1.13.5.3.21.6 | ScalarairIRmPmPump1ManOpRunning | read-only | mandatory | Pump 1 manual operation running (5805) |
| 1.3.6.1.4.1.318.1.1.13.5.3.21.10 | NodeairIRmPmPump1StartTemperature | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.21.10.1 | ScalarairIRmPmPump1StartTemperatureK | read-write | mandatory | Pump 1 starting temperature in tenths of Kelvins (5809) |
| 1.3.6.1.4.1.318.1.1.13.5.3.21.10.2 | ScalarairIRmPmPump1StartTemperatureF | read-write | mandatory | Pump 1 starting temperature in tenths of degrees Fahrenheit (5809) |
| 1.3.6.1.4.1.318.1.1.13.5.3.21.11 | NodeairIRmPmPump1Hysteresis | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.21.11.1 | ScalarairIRmPmPump1HysteresisK | read-write | mandatory | Pump 1 hysteresis in tenths of Kelvins (5810) |
| 1.3.6.1.4.1.318.1.1.13.5.3.21.11.2 | ScalarairIRmPmPump1HysteresisF | read-write | mandatory | Pump 1 hysteresis in tenths of degrees Fahrenheit (5810) |
| 1.3.6.1.4.1.318.1.1.13.5.3.21.12 | NodeairIRmPmPump1LinearRange | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.21.12.1 | ScalarairIRmPmPump1LinearRangeK | read-write | mandatory | Pump 1 linear range in tenths of Kelvins (5811) |
| 1.3.6.1.4.1.318.1.1.13.5.3.21.12.2 | ScalarairIRmPmPump1LinearRangeF | read-write | mandatory | Pump 1 linear range in tenths of degrees Fahrenheit (5811) |
| 1.3.6.1.4.1.318.1.1.13.5.3.21.13 | ScalarairIRmPmPump1PressureSetpoint | read-write | mandatory | Pump 1 pressure setpoint in tenths of Bars (5812) |
| 1.3.6.1.4.1.318.1.1.13.5.3.21.21 | ScalarairIRmPmPump1Runtime | read-only | mandatory | Pump 1 runtime in hours (5820) |
| 1.3.6.1.4.1.318.1.1.13.5.3.21.22 | ScalarairIRmPmPump1Speed | read-only | mandatory | Pump 1 speed in percent (5821) |
| 1.3.6.1.4.1.318.1.1.13.5.3.21.28 | ScalarairIRmPmPump1ControlCycle | read-write | mandatory | Pump 1 control cycle length in seconds (5827) |
| 1.3.6.1.4.1.318.1.1.13.5.3.21.29 | ScalarairIRmPmPump1MaxAdjust | read-write | mandatory | Pump 1 maximum adjustment in percent (5828) |
| 1.3.6.1.4.1.318.1.1.13.5.3.21.30 | ScalarairIRmPmPump1ControlFactor | read-write | mandatory | Pump 1 control factor setting (5829) |
| 1.3.6.1.4.1.318.1.1.13.5.3.22 | NodeairIRmPmPump2 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.22.2 | ScalarairIRmPmPump2ManOpEnable | read-only | mandatory | Pump 2 manual operation enable state (5901) |
| 1.3.6.1.4.1.318.1.1.13.5.3.22.3 | ScalarairIRmPmPump2Running | read-only | mandatory | Pump 2 running (5902) |
| 1.3.6.1.4.1.318.1.1.13.5.3.22.6 | ScalarairIRmPmPump2ManOpRunning | read-only | mandatory | Pump 2 manual operation running (5905) |
| 1.3.6.1.4.1.318.1.1.13.5.3.22.10 | NodeairIRmPmPump2StartTemperature | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.22.10.1 | ScalarairIRmPmPump2StartTemperatureK | read-write | mandatory | Pump 2 starting temperature in tenths of Kelvins (5909) |
| 1.3.6.1.4.1.318.1.1.13.5.3.22.10.2 | ScalarairIRmPmPump2StartTemperatureF | read-write | mandatory | Pump 2 starting temperature in tenths of degrees Fahrenheit (5909) |
| 1.3.6.1.4.1.318.1.1.13.5.3.22.11 | NodeairIRmPmPump2Hysteresis | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.22.11.1 | ScalarairIRmPmPump2HysteresisK | read-write | mandatory | Pump 2 hysteresis in tenths of Kelvins (5910) |
| 1.3.6.1.4.1.318.1.1.13.5.3.22.11.2 | ScalarairIRmPmPump2HysteresisF | read-write | mandatory | Pump 2 hysteresis in tenths of degrees Fahrenheit (5910) |
| 1.3.6.1.4.1.318.1.1.13.5.3.22.12 | NodeairIRmPmPump2LinearRange | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.22.12.1 | ScalarairIRmPmPump2LinearRangeK | read-write | mandatory | Pump 2 linear range in tenths of Kelvins (5911) |
| 1.3.6.1.4.1.318.1.1.13.5.3.22.12.2 | ScalarairIRmPmPump2LinearRangeF | read-write | mandatory | Pump 2 linear range in tenths of degrees Fahrenheit (5911) |
| 1.3.6.1.4.1.318.1.1.13.5.3.22.13 | ScalarairIRmPmPump2PressureSetpoint | read-write | mandatory | Pump 2 pressure setpoint in tenths of Bars (5912) |
| 1.3.6.1.4.1.318.1.1.13.5.3.22.21 | ScalarairIRmPmPump2Runtime | read-only | mandatory | Pump 2 runtime in hours (5920) |
| 1.3.6.1.4.1.318.1.1.13.5.3.22.22 | ScalarairIRmPmPump2Speed | read-only | mandatory | Pump 2 speed in percent (5921) |
| 1.3.6.1.4.1.318.1.1.13.5.3.22.28 | ScalarairIRmPmPump2ControlCycle | read-write | mandatory | Pump 2 control cycle length in seconds (5927) |
| 1.3.6.1.4.1.318.1.1.13.5.3.22.29 | ScalarairIRmPmPump2MaxAdjust | read-write | mandatory | Pump 2 maximum adjustment in percent (5928) |
| 1.3.6.1.4.1.318.1.1.13.5.3.22.30 | ScalarairIRmPmPump2ControlFactor | read-write | mandatory | Pump 2 control factor setting (5929) |
| 1.3.6.1.4.1.318.1.1.13.5.3.23 | NodeairIRmPmPump3 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.23.2 | ScalarairIRmPmPump3ManOpEnable | read-only | mandatory | Pump 3 manual operation enable state (6001) |
| 1.3.6.1.4.1.318.1.1.13.5.3.23.3 | ScalarairIRmPmPump3Running | read-only | mandatory | Pump 3 running (6002) |
| 1.3.6.1.4.1.318.1.1.13.5.3.23.6 | ScalarairIRmPmPump3ManOpRunning | read-only | mandatory | Pump 3 manual operation running (6005) |
| 1.3.6.1.4.1.318.1.1.13.5.3.23.10 | NodeairIRmPmPump3StartTemperature | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.23.10.1 | ScalarairIRmPmPump3StartTemperatureK | read-write | mandatory | Pump 3 starting temperature in tenths of Kelvins (6009) |
| 1.3.6.1.4.1.318.1.1.13.5.3.23.10.2 | ScalarairIRmPmPump3StartTemperatureF | read-write | mandatory | Pump 3 starting temperature in tenths of degrees Fahrenheit (6009) |
| 1.3.6.1.4.1.318.1.1.13.5.3.23.11 | NodeairIRmPmPump3Hysteresis | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.23.11.1 | ScalarairIRmPmPump3HysteresisK | read-write | mandatory | Pump 3 hysteresis in tenths of Kelvins (6010) |
| 1.3.6.1.4.1.318.1.1.13.5.3.23.11.2 | ScalarairIRmPmPump3HysteresisF | read-write | mandatory | Pump 3 hysteresis in tenths of degrees Fahrenheit (6010) |
| 1.3.6.1.4.1.318.1.1.13.5.3.23.12 | NodeairIRmPmPump3LinearRange | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.23.12.1 | ScalarairIRmPmPump3LinearRangeK | read-write | mandatory | Pump 3 linear range in tenths of Kelvins (6011) |
| 1.3.6.1.4.1.318.1.1.13.5.3.23.12.2 | ScalarairIRmPmPump3LinearRangeF | read-write | mandatory | Pump 3 linear range in tenths of degrees Fahrenheit (6011) |
| 1.3.6.1.4.1.318.1.1.13.5.3.23.13 | ScalarairIRmPmPump3PressureSetpoint | read-write | mandatory | Pump 3 pressure setpoint in tenths of Bars (6012) |
| 1.3.6.1.4.1.318.1.1.13.5.3.23.21 | ScalarairIRmPmPump3Runtime | read-only | mandatory | Pump 3 runtime in hours (6020) |
| 1.3.6.1.4.1.318.1.1.13.5.3.23.22 | ScalarairIRmPmPump3Speed | read-only | mandatory | Pump 3 speed in percent (6021) |
| 1.3.6.1.4.1.318.1.1.13.5.3.23.28 | ScalarairIRmPmPump3ControlCycle | read-write | mandatory | Pump 3 control cycle length in seconds (6027) |
| 1.3.6.1.4.1.318.1.1.13.5.3.23.29 | ScalarairIRmPmPump3MaxAdjust | read-write | mandatory | Pump 3 maximum adjustment in percent (6028) |
| 1.3.6.1.4.1.318.1.1.13.5.3.23.30 | ScalarairIRmPmPump3ControlFactor | read-write | mandatory | Pump 3 control factor setting (6029) |
| 1.3.6.1.4.1.318.1.1.13.5.3.24 | NodeairIRmPmPump4 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.24.2 | ScalarairIRmPmPump4ManOpEnable | read-only | mandatory | Pump 4 manual operation enable state (6101) |
| 1.3.6.1.4.1.318.1.1.13.5.3.24.3 | ScalarairIRmPmPump4Running | read-only | mandatory | Pump 4 running (6102) |
| 1.3.6.1.4.1.318.1.1.13.5.3.24.6 | ScalarairIRmPmPump4ManOpRunning | read-only | mandatory | Pump 4 manual operation running (6105) |
| 1.3.6.1.4.1.318.1.1.13.5.3.24.10 | NodeairIRmPmPump4StartTemperature | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.24.10.1 | ScalarairIRmPmPump4StartTemperatureK | read-write | mandatory | Pump 4 starting temperature in tenths of Kelvins (6109) |
| 1.3.6.1.4.1.318.1.1.13.5.3.24.10.2 | ScalarairIRmPmPump4StartTemperatureF | read-write | mandatory | Pump 4 starting temperature in tenths of degrees Fahrenheit (6109) |
| 1.3.6.1.4.1.318.1.1.13.5.3.24.11 | NodeairIRmPmPump4Hysteresis | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.24.11.1 | ScalarairIRmPmPump4HysteresisK | read-write | mandatory | Pump 4 hysteresis in tenths of Kelvins (6110) |
| 1.3.6.1.4.1.318.1.1.13.5.3.24.11.2 | ScalarairIRmPmPump4HysteresisF | read-write | mandatory | Pump 4 hysteresis in tenths of degrees Fahrenheit (6110) |
| 1.3.6.1.4.1.318.1.1.13.5.3.24.12 | NodeairIRmPmPump4LinearRange | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.24.12.1 | ScalarairIRmPmPump4LinearRangeK | read-write | mandatory | Pump 4 linear range in tenths of Kelvins (6111) |
| 1.3.6.1.4.1.318.1.1.13.5.3.24.12.2 | ScalarairIRmPmPump4LinearRangeF | read-write | mandatory | Pump 4 linear range in tenths of degrees Fahrenheit (6111) |
| 1.3.6.1.4.1.318.1.1.13.5.3.24.13 | ScalarairIRmPmPump4PressureSetpoint | read-write | mandatory | Pump 4 pressure setpoint in tenths of Bars (6112) |
| 1.3.6.1.4.1.318.1.1.13.5.3.24.21 | ScalarairIRmPmPump4Runtime | read-only | mandatory | Pump 4 runtime in hours (6120) |
| 1.3.6.1.4.1.318.1.1.13.5.3.24.22 | ScalarairIRmPmPump4Speed | read-only | mandatory | Pump 4 speed in percent (6121) |
| 1.3.6.1.4.1.318.1.1.13.5.3.24.28 | ScalarairIRmPmPump4ControlCycle | read-write | mandatory | Pump 4 control cycle length in seconds (6127) |
| 1.3.6.1.4.1.318.1.1.13.5.3.24.29 | ScalarairIRmPmPump4MaxAdjust | read-write | mandatory | Pump 4 maximum adjustment in percent (6128) |
| 1.3.6.1.4.1.318.1.1.13.5.3.24.30 | ScalarairIRmPmPump4ControlFactor | read-write | mandatory | Pump 4 control factor setting (6129) |
| 1.3.6.1.4.1.318.1.1.13.5.3.25 | NodeairIRmPmHotgasHeating | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.25.3 | ScalarairIRmPmHotgasHeatRunning | read-only | mandatory | Hotgas heat running state. (6202) |
| 1.3.6.1.4.1.318.1.1.13.5.3.26 | NodeairIRmPmPWWHeating | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.26.2 | ScalarairIRmPmPWWHeatingManOpEnable | read-only | mandatory | PWW-heating manual operation enable (6301) |
| 1.3.6.1.4.1.318.1.1.13.5.3.26.3 | ScalarairIRmPmPWWHeatingRunning | read-only | mandatory | PWW-heating running (6302) |
| 1.3.6.1.4.1.318.1.1.13.5.3.26.4 | ScalarairIRmPmPWWHeatingManOpRunning | read-only | mandatory | PWW-heating manual operation running (6303) |
| 1.3.6.1.4.1.318.1.1.13.5.3.26.9 | ScalarairIRmPmPWWHeatingType | read-only | mandatory | PWW-heating type (6308) |
| 1.3.6.1.4.1.318.1.1.13.5.3.26.10 | NodeairIRmPmPWWHeatingStartTemp | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.26.10.1 | ScalarairIRmPmPWWHeatingStartTempK | read-write | mandatory | PWW-heating starting temperature in Kelvins (6309) |
| 1.3.6.1.4.1.318.1.1.13.5.3.26.10.2 | ScalarairIRmPmPWWHeatingStartTempF | read-write | mandatory | PWW-heating starting temperature in degrees Fahrenheit (6309) |
| 1.3.6.1.4.1.318.1.1.13.5.3.26.12 | NodeairIRmPmPWWHeatingHysteresis | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.26.12.1 | ScalarairIRmPmPWWHeatingHysteresisK | read-write | mandatory | PWW-heating hysteresis in Kelvins (6311) |
| 1.3.6.1.4.1.318.1.1.13.5.3.26.12.2 | ScalarairIRmPmPWWHeatingHysteresisF | read-write | mandatory | PWW-heating hysteresis in degrees Fahrenheit (6311) |
| 1.3.6.1.4.1.318.1.1.13.5.3.26.13 | NodeairIRmPmPWWHeatingLinearRange | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.26.13.1 | ScalarairIRmPmPWWHeatingLinearRangeK | read-write | mandatory | PWW-heating linear range in Kelvins (6312) |
| 1.3.6.1.4.1.318.1.1.13.5.3.26.13.2 | ScalarairIRmPmPWWHeatingLinearRangeF | read-write | mandatory | PWW-heating linear range in degrees Fahrenheit (6312) |
| 1.3.6.1.4.1.318.1.1.13.5.3.26.16 | ScalarairIRmPmPWWHeatingCurrentValue | read-write | mandatory | PWW-heating current value in percent (6315) |
| 1.3.6.1.4.1.318.1.1.13.5.3.26.17 | ScalarairIRmPmPWWHeatingManOpValue | read-write | mandatory | PWW-heating manual operation value in percent (6316) |
| 1.3.6.1.4.1.318.1.1.13.5.3.27 | NodeairIRmPmHumidifier1 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.27.2 | ScalarairIRmPmHumidifier1ManOpEnable | read-only | mandatory | Humidifier #1 manual operation enable (6401) |
| 1.3.6.1.4.1.318.1.1.13.5.3.27.3 | ScalarairIRmPmHumidifier1Running | read-only | mandatory | Humidifier #1 running state (6402) |
| 1.3.6.1.4.1.318.1.1.13.5.3.27.5 | ScalarairIRmPmHumidifier1ManOpRunning | read-only | mandatory | Humidifier #1 manual operation running state (6404) |
| 1.3.6.1.4.1.318.1.1.13.5.3.27.17 | ScalarairIRmPmHumidifier1Type | read-only | mandatory | Humidifier #1 type (6416) |
| 1.3.6.1.4.1.318.1.1.13.5.3.27.18 | ScalarairIRmPmHumidifier1StartHumidity | read-write | mandatory | Humidifier #1 start humidity in tenths of percent relative humidity (6417) |
| 1.3.6.1.4.1.318.1.1.13.5.3.27.20 | ScalarairIRmPmHumidifier1Hysteresis | read-write | mandatory | Humidifier #1 hysteresis in tenths of percent relative humidity (6419) |
| 1.3.6.1.4.1.318.1.1.13.5.3.27.21 | ScalarairIRmPmHumidifier1LinearRange | read-write | mandatory | Humidifier #1 linear range in tenths of percent relative humidity per Kelvin (6420) |
| 1.3.6.1.4.1.318.1.1.13.5.3.27.27 | ScalarairIRmPmHumidifier1Runtime | read-only | mandatory | Humidifier #1 runtime in hours (6426) |
| 1.3.6.1.4.1.318.1.1.13.5.3.27.28 | ScalarairIRmPmHumidifier1CurrentValue | read-only | mandatory | Humidifier #1 current value in percent (6427) |
| 1.3.6.1.4.1.318.1.1.13.5.3.27.29 | ScalarairIRmPmHumidifier1ManOpValue | read-write | mandatory | Humidifier #1 manual operation value in percent (6428) |
| 1.3.6.1.4.1.318.1.1.13.5.3.28 | NodeairIRmPmHumidifier2 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.28.2 | ScalarairIRmPmHumidifier2ManOpEnable | read-only | mandatory | Humidifier #2 manual operation enable (6501) |
| 1.3.6.1.4.1.318.1.1.13.5.3.28.3 | ScalarairIRmPmHumidifier2Running | read-only | mandatory | Humidifier #2 running state (6502) |
| 1.3.6.1.4.1.318.1.1.13.5.3.28.5 | ScalarairIRmPmHumidifier2ManOpRunning | read-only | mandatory | Humidifier #2 manual operation running state (6504) |
| 1.3.6.1.4.1.318.1.1.13.5.3.28.17 | ScalarairIRmPmHumidifier2Type | read-only | mandatory | Humidifier #2 type (6516) |
| 1.3.6.1.4.1.318.1.1.13.5.3.28.18 | ScalarairIRmPmHumidifier2StartHumidity | read-write | mandatory | Humidifier #2 start humidity in tenths of percent relative humidity (6517) |
| 1.3.6.1.4.1.318.1.1.13.5.3.28.20 | ScalarairIRmPmHumidifier2Hysteresis | read-write | mandatory | Humidifier #2 hysteresis in tenths of percent relative humidity (6519) |
| 1.3.6.1.4.1.318.1.1.13.5.3.28.21 | ScalarairIRmPmHumidifier2LinearRange | read-write | mandatory | Humidifier #2 linear range in tenths of percent relative humidity per Kelvin (6520) |
| 1.3.6.1.4.1.318.1.1.13.5.3.28.27 | ScalarairIRmPmHumidifier2Runtime | read-only | mandatory | Humidifier #2 runtime in hours (6526) |
| 1.3.6.1.4.1.318.1.1.13.5.3.28.28 | ScalarairIRmPmHumidifier2CurrentValue | read-only | mandatory | Humidifier #2 current value in percent (6527) |
| 1.3.6.1.4.1.318.1.1.13.5.3.28.29 | ScalarairIRmPmHumidifier2ManOpValue | read-write | mandatory | Humidifier #2 manual operation value in percent (6528) |
| 1.3.6.1.4.1.318.1.1.13.5.3.31 | NodeairIRmPmDehumidification | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.31.2 | ScalarairIRmPmDehumidificManOpEnable | read-only | mandatory | Dehumidifier manual operation enable setting (6801) |
| 1.3.6.1.4.1.318.1.1.13.5.3.31.3 | ScalarairIRmPmDehumidificRunning | read-only | mandatory | Dehumidifier running state (6802) |
| 1.3.6.1.4.1.318.1.1.13.5.3.31.5 | ScalarairIRmPmDehumidificManOpRunning | read-only | mandatory | Dehumidifier manual operation running (6804) |
| 1.3.6.1.4.1.318.1.1.13.5.3.31.10 | ScalarairIRmPmDehumidificStartHumidity | read-write | mandatory | Dehumidifier start humidity in tenths of percent relative humidity (6809) |
| 1.3.6.1.4.1.318.1.1.13.5.3.31.12 | ScalarairIRmPmDehumidificHysteresis | read-write | mandatory | Dehumidifier hysteresis in tenths of percent relative humidity (6811) |
| 1.3.6.1.4.1.318.1.1.13.5.3.31.18 | NodeairIRmPmDehumidificMinWaterTemp | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.31.18.1 | ScalarairIRmPmDehumidificMinWaterTempC | read-write | mandatory | Dehumidifier minimum water temperature in tenths of degrees Celsius (6817) |
| 1.3.6.1.4.1.318.1.1.13.5.3.31.18.2 | ScalarairIRmPmDehumidificMinWaterTempF | read-write | mandatory | Dehumidifier minimum water temperature in tenths of degrees Fahrenheit (6817) |
| 1.3.6.1.4.1.318.1.1.13.5.3.31.19 | NodeairIRmPmDehumidificMaxWaterTemp | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.31.19.1 | ScalarairIRmPmDehumidificMaxWaterTempC | read-write | mandatory | Dehumidifier maximum water temperature in tenths of degrees Celsius (6818) |
| 1.3.6.1.4.1.318.1.1.13.5.3.31.19.2 | ScalarairIRmPmDehumidificMaxWaterTempF | read-write | mandatory | Dehumidifier maximum water temperature in tenths of degrees Fahrenheit (6818) |
| 1.3.6.1.4.1.318.1.1.13.5.3.31.21 | ScalarairIRmPmDehumidificRuntime | read-write | mandatory | Dehumidifier runtime in hours (6820) |
| 1.3.6.1.4.1.318.1.1.13.5.3.32 | NodeairIRmPmFan1 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.32.2 | ScalarairIRmPmFan1ManOpEnable | read-only | mandatory | Fan 1 manual operation enable (6901) |
| 1.3.6.1.4.1.318.1.1.13.5.3.32.3 | ScalarairIRmPmFan1Running | read-only | mandatory | Fan 1 running (6902) |
| 1.3.6.1.4.1.318.1.1.13.5.3.32.6 | ScalarairIRmPmFan1ManOpRunning | read-only | mandatory | Fan 1 manual operation running (6905) |
| 1.3.6.1.4.1.318.1.1.13.5.3.32.9 | ScalarairIRmPmFan1Type | read-only | mandatory | Fan 1 type (6908) |
| 1.3.6.1.4.1.318.1.1.13.5.3.32.32 | ScalarairIRmPmFan1Runtime | read-only | mandatory | Fan 1 runtime in hours (6931) |
| 1.3.6.1.4.1.318.1.1.13.5.3.32.33 | ScalarairIRmPmFan1Speed | read-only | mandatory | Fan 1 speed in percent (6932) |
| 1.3.6.1.4.1.318.1.1.13.5.3.32.34 | ScalarairIRmPmFan1ManOpSpeed | read-only | mandatory | Fan 1 manual operation speed in percent (6933) |
| 1.3.6.1.4.1.318.1.1.13.5.3.33 | NodeairIRmPmFan2 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.33.2 | ScalarairIRmPmFan2ManOpEnable | read-only | mandatory | Fan 1 manual operation enable (7001) |
| 1.3.6.1.4.1.318.1.1.13.5.3.33.3 | ScalarairIRmPmFan2Running | read-only | mandatory | Fan 1 running (7002) |
| 1.3.6.1.4.1.318.1.1.13.5.3.33.6 | ScalarairIRmPmFan2ManOpRunning | read-only | mandatory | Fan 1 manual operation running (7005) |
| 1.3.6.1.4.1.318.1.1.13.5.3.33.9 | ScalarairIRmPmFan2Type | read-only | mandatory | Fan 2 type (7008) |
| 1.3.6.1.4.1.318.1.1.13.5.3.33.32 | ScalarairIRmPmFan2Runtime | read-only | mandatory | Fan 1 runtime in hours (7031) |
| 1.3.6.1.4.1.318.1.1.13.5.3.33.33 | ScalarairIRmPmFan2Speed | read-only | mandatory | Fan 1 speed in percent (7032) |
| 1.3.6.1.4.1.318.1.1.13.5.3.33.34 | ScalarairIRmPmFan2ManOpSpeed | read-only | mandatory | Fan 1 manual operation speed in percent (7033) |
| 1.3.6.1.4.1.318.1.1.13.5.3.34 | NodeairIRmPmFan3 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.34.2 | ScalarairIRmPmFan3ManOpEnable | read-only | mandatory | Fan 1 manual operation enable (7101) |
| 1.3.6.1.4.1.318.1.1.13.5.3.34.3 | ScalarairIRmPmFan3Running | read-only | mandatory | Fan 1 running (7102) |
| 1.3.6.1.4.1.318.1.1.13.5.3.34.6 | ScalarairIRmPmFan3ManOpRunning | read-only | mandatory | Fan 1 manual operation running (7105) |
| 1.3.6.1.4.1.318.1.1.13.5.3.34.9 | ScalarairIRmPmFan3Type | read-only | mandatory | Fan 3 type (7108) |
| 1.3.6.1.4.1.318.1.1.13.5.3.34.32 | ScalarairIRmPmFan3Runtime | read-only | mandatory | Fan 1 runtime in hours (7131) |
| 1.3.6.1.4.1.318.1.1.13.5.3.34.33 | ScalarairIRmPmFan3Speed | read-only | mandatory | Fan 1 speed in percent (7132) |
| 1.3.6.1.4.1.318.1.1.13.5.3.34.34 | ScalarairIRmPmFan3ManOpSpeed | read-only | mandatory | Fan 1 manual operation speed in percent (7133) |
| 1.3.6.1.4.1.318.1.1.13.5.3.35 | NodeairIRmPmLouver1 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.35.2 | ScalarairIRmPmLouver1ManOpEnable | read-only | mandatory | Louver 1 manual operation enable (7201) |
| 1.3.6.1.4.1.318.1.1.13.5.3.35.3 | ScalarairIRmPmLouver1Position | read-only | mandatory | Louver 1 position (7202) |
| 1.3.6.1.4.1.318.1.1.13.5.3.35.4 | ScalarairIRmPmLouver1ManOpPosition | read-only | mandatory | Louver 1 manual operation position setting (7203) |
| 1.3.6.1.4.1.318.1.1.13.5.3.36 | NodeairIRmPmLouver2 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.36.2 | ScalarairIRmPmLouver2ManOpEnable | read-only | mandatory | Louver 2 manual operation enable (7301) |
| 1.3.6.1.4.1.318.1.1.13.5.3.36.3 | ScalarairIRmPmLouver2Position | read-only | mandatory | Louver 2 position (7302) |
| 1.3.6.1.4.1.318.1.1.13.5.3.36.4 | ScalarairIRmPmLouver2ManOpPosition | read-only | mandatory | Louver 2 manual operation position setting (7303) |
| 1.3.6.1.4.1.318.1.1.13.5.3.37 | NodeairIRmPmLouver3 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.37.2 | ScalarairIRmPmLouver3ManOpEnable | read-only | mandatory | Louver 3 manual operation enable (7401) |
| 1.3.6.1.4.1.318.1.1.13.5.3.37.3 | ScalarairIRmPmLouver3Position | read-only | mandatory | Louver 3 position (7402) |
| 1.3.6.1.4.1.318.1.1.13.5.3.37.4 | ScalarairIRmPmLouver3ManOpPosition | read-only | mandatory | Louver 3 manual operation position setting (7403) |
| 1.3.6.1.4.1.318.1.1.13.5.3.38 | NodeairIRmPmAuxAlarm1 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.39 | NodeairIRmPmAuxAlarm2 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.40 | NodeairIRmPmAuxAlarm3 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.41 | NodeairIRmPmAuxAlarm4 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.42 | NodeairIRmPmAuxAlarm5 | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.43 | NodeairIRmPmAlarmBits | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.43.1 | ScalarairIRmPmFan1Failure | read-only | mandatory | Fan #1 failure (8500). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.2 | ScalarairIRmPmFan2Failure | read-only | mandatory | Fan #2 failure (8501). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.3 | ScalarairIRmPmFan3Failure | read-only | mandatory | Fan #3 failure (8502). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.4 | ScalarairIRmPmCompressor1Failure | read-only | mandatory | Compressor #1 failure (8503). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.5 | ScalarairIRmPmCompressor2Failure | read-only | mandatory | Compressor #2 failure (8504). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.6 | ScalarairIRmPmWaterDetector | read-only | mandatory | Water detector alarm (8505). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.7 | ScalarairIRmPmPhaseFailure | read-only | mandatory | Phase failure (8506). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.8 | ScalarairIRmPmFireSmokeDetector | read-only | mandatory | Fire/smoke detector (8507). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.9 | ScalarairIRmPmReturnAirTemperatureTooHigh | read-only | mandatory | Return air temperature too high (8508). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.10 | ScalarairIRmPmReturnAirHumidityTooHigh | read-only | mandatory | Return air humidity too high (8509). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.11 | ScalarairIRmPmSupplyAirTemperatureTooHigh | read-only | mandatory | Supply air temperature too high (8510). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.12 | ScalarairIRmPmSupplyAirHumidityTooHigh | read-only | mandatory | Supply air humidity too high (8511). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.13 | ScalarairIRmPmWaterTemperatureTooHigh | read-only | mandatory | Water temperature too high (8512). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.14 | ScalarairIRmPmReturnAirTemperatureTooLow | read-only | mandatory | Return air temperature too low (8513). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.15 | ScalarairIRmPmReturnAirHumidityTooLow | read-only | mandatory | Return air humidity too low (8514). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.16 | ScalarairIRmPmSupplyAirTemperatureTooLow | read-only | mandatory | Supply air temperature too low (8515). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.17 | ScalarairIRmPmSupplyAirHumidityTooLow | read-only | mandatory | Supply air humidity too low (8516). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.18 | ScalarairIRmPmWaterTemperatureTooLow | read-only | mandatory | Water temperature too low (8517). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.19 | ScalarairIRmPmSensor1Failure | read-only | mandatory | Sensor #1 failure (8518). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.20 | ScalarairIRmPmSensor2Failure | read-only | mandatory | Sensor #2 failure (8519). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.21 | ScalarairIRmPmSensor3Failure | read-only | mandatory | Sensor #3 failure (8520). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.22 | ScalarairIRmPmSensor4Failure | read-only | mandatory | Sensor #4 failure (8521). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.23 | ScalarairIRmPmSensor5Failure | read-only | mandatory | Sensor #5 failure (8522). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.24 | ScalarairIRmPmSensor6Failure | read-only | mandatory | Sensor #6 failure (8523). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.25 | ScalarairIRmPmSensor7Failure | read-only | mandatory | Sensor #7 failure (8524). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.26 | ScalarairIRmPmSensor8Failure | read-only | mandatory | Sensor #8 failure (8525). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.27 | ScalarairIRmPmSensor9Failure | read-only | mandatory | Sensor #9 failure (8526). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.28 | ScalarairIRmPmSensor10Failure | read-only | mandatory | Sensor #10 failure (8527). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.29 | ScalarairIRmPmSensor11Failure | read-only | mandatory | Sensor #11 failure (8528). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.30 | ScalarairIRmPmSensor12Failure | read-only | mandatory | Sensor #12 failure (8529). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.31 | ScalarairIRmPmSensor13Failure | read-only | mandatory | Sensor #13 failure (8530). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.32 | ScalarairIRmPmSensor14Failure | read-only | mandatory | Sensor #14 failure (8531). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.33 | ScalarairIRmPmSensor15Failure | read-only | mandatory | Sensor #15 failure (8532). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.34 | ScalarairIRmPmSensor16Failure | read-only | mandatory | Sensor #16 failure (8533). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.35 | ScalarairIRmPmSensor17Failure | read-only | mandatory | Sensor #17 failure (8534). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.36 | ScalarairIRmPmSensor18Failure | read-only | mandatory | Sensor #18 failure (8535). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.37 | ScalarairIRmPmSensor19Failure | read-only | mandatory | Sensor #19 failure (8536). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.38 | ScalarairIRmPmSensor20Failure | read-only | mandatory | Sensor #20 failure (8537). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.39 | ScalarairIRmPmSensor21Failure | read-only | mandatory | Sensor #21 failure (8538). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.40 | ScalarairIRmPmSensor1Defect | read-only | mandatory | Sensor #1 defect (8539). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.41 | ScalarairIRmPmSensor2Defect | read-only | mandatory | Sensor #2 defect (8540). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.42 | ScalarairIRmPmSensor3Defect | read-only | mandatory | Sensor #3 defect (8541). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.43 | ScalarairIRmPmSensor4Defect | read-only | mandatory | Sensor #4 defect (8542). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.44 | ScalarairIRmPmSensor5Defect | read-only | mandatory | Sensor #5 defect (8543). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.45 | ScalarairIRmPmSensor6Defect | read-only | mandatory | Sensor #6 defect (8544). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.46 | ScalarairIRmPmSensor7Defect | read-only | mandatory | Sensor #7 defect (8545). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.47 | ScalarairIRmPmSensor8Defect | read-only | mandatory | Sensor #8 defect (8546). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.48 | ScalarairIRmPmSensor9Defect | read-only | mandatory | Sensor #9 defect (8547). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.49 | ScalarairIRmPmSensor10Defect | read-only | mandatory | Sensor #10 defect (8548). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.50 | ScalarairIRmPmSensor11Defect | read-only | mandatory | Sensor #11 defect (8549). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.51 | ScalarairIRmPmSensor12Defect | read-only | mandatory | Sensor #12 defect (8550). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.52 | ScalarairIRmPmSensor13Defect | read-only | mandatory | Sensor #13 defect (8551). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.53 | ScalarairIRmPmSensor14Defect | read-only | mandatory | Sensor #14 defect (8552). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.54 | ScalarairIRmPmSensor15Defect | read-only | mandatory | Sensor #15 defect (8553). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.55 | ScalarairIRmPmSensor16Defect | read-only | mandatory | Sensor #16 defect (8554). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.56 | ScalarairIRmPmSensor17Defect | read-only | mandatory | Sensor #17 defect (8555). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.57 | ScalarairIRmPmSensor18Defect | read-only | mandatory | Sensor #18 defect (8556) |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.58 | ScalarairIRmPmSensor19Defect | read-only | mandatory | Sensor #19 defect (8557). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.59 | ScalarairIRmPmSensor20Defect | read-only | mandatory | Sensor #20 defect (8558). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.60 | ScalarairIRmPmSensor21Defect | read-only | mandatory | Sensor #21 defect (8559). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.61 | ScalarairIRmPmCompressor1Alarm | read-only | mandatory | Compressor #1 alarm (8560). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.62 | ScalarairIRmPmCompressor2Alarm | read-only | mandatory | Compressor #2 alarm (8561). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.63 | ScalarairIRmPmCompressor1LowPressure | read-only | mandatory | Compressor #1 low pressure (8562). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.64 | ScalarairIRmPmCompressor2LowPressure | read-only | mandatory | Compressor #2 low pressure (8563). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.65 | ScalarairIRmPmReheat1Failure | read-only | mandatory | Reheat #1 failure (8564). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.66 | ScalarairIRmPmReheat2Failure | read-only | mandatory | Reheat #2 failure (8565). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.67 | ScalarairIRmPmReheat3Failure | read-only | mandatory | Reheat #3 failure (8566). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.68 | ScalarairIRmPmReheat4Failure | read-only | mandatory | Reheat #4 failure (8567). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.69 | ScalarairIRmPmDrycooler1Failure | read-only | mandatory | Drycooler #1 failure (8568). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.70 | ScalarairIRmPmDrycooler2Failure | read-only | mandatory | Drycooler #2 failure (8569). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.71 | ScalarairIRmPmDrycooler3Failure | read-only | mandatory | Drycooler #3 failure (8570). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.72 | ScalarairIRmPmDrycooler4Failure | read-only | mandatory | Drycooler #4 failure (8571). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.73 | ScalarairIRmPmPump1Failure | read-only | mandatory | Pump #1 failure (8572). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.74 | ScalarairIRmPmPump2Failure | read-only | mandatory | Pump #2 failure (8573). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.75 | ScalarairIRmPmPump3Failure | read-only | mandatory | Pump #3 failure (8574). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.76 | ScalarairIRmPmPump4Failure | read-only | mandatory | Pump #4 failure (8575). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.77 | ScalarairIRmPmHumidifier1Failure | read-only | mandatory | Humidifier #1 failure (8576). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.78 | ScalarairIRmPmHumidifier2Failure | read-only | mandatory | Humidifier #2 failure (8577). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.79 | ScalarairIRmPmHumidifier3Failure | read-only | mandatory | Humidifier #3 failure (8578). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.80 | ScalarairIRmPmHumidifier1Alarm5us | read-only | mandatory | Humidifier #1 5us alarm (8579). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.81 | ScalarairIRmPmHumidifier2Alarm5us | read-only | mandatory | Humidifier #2 5us alarm (8580). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.82 | ScalarairIRmPmHumidifier3Alarm5us | read-only | mandatory | Humidifier #3 5us alarm (8581). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.83 | ScalarairIRmPmHumidifier1Alarm20us | read-only | mandatory | Humidifier #1 20us alarm (8582). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.84 | ScalarairIRmPmHumidifier2Alarm20us | read-only | mandatory | Humidifier #2 20us alarm (8583). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.85 | ScalarairIRmPmHumidifier3Alarm20us | read-only | mandatory | Humidifier #3 20us alarm (8584). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.86 | ScalarairIRmPmFan1Alarm | read-only | mandatory | Fan #1 alarm (8585). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.87 | ScalarairIRmPmFan2Alarm | read-only | mandatory | Fan #2 alarm (8586). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.88 | ScalarairIRmPmFan3Alarm | read-only | mandatory | Fan #3 alarm (8587). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.89 | ScalarairIRmPmFilter1Clogged | read-only | mandatory | Filter #1 clogged (8588). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.90 | ScalarairIRmPmFilter2Clogged | read-only | mandatory | Filter #2 clogged (8589). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.91 | ScalarairIRmPmFilter3Clogged | read-only | mandatory | Filter #3 clogged (8590). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.92 | ScalarairIRmPmAuxiliaryAlarm1 | read-only | mandatory | Auxiliary #1 alarm (8591). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.93 | ScalarairIRmPmAuxiliaryAlarm2 | read-only | mandatory | Auxiliary #2 alarm (8592). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.94 | ScalarairIRmPmAuxiliaryAlarm3 | read-only | mandatory | Auxiliary #3 alarm (8593). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.95 | ScalarairIRmPmAuxiliaryAlarm4 | read-only | mandatory | Auxiliary #4 alarm (8594). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.96 | ScalarairIRmPmAuxiliaryAlarm5 | read-only | mandatory | Auxiliary #5 alarm (8595). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.97 | ScalarairIRmPmAuxiliaryAlarm6 | read-only | mandatory | Auxiliary #6 alarm (8596). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.98 | ScalarairIRmPmAuxiliaryAlarm7 | read-only | mandatory | Auxiliary #7 alarm (8597). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.99 | ScalarairIRmPmAuxiliaryAlarm8 | read-only | mandatory | Auxiliary #8 alarm (8598). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.100 | ScalarairIRmPmAuxiliaryAlarm9 | read-only | mandatory | Auxiliary #9 alarm (8599). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.101 | ScalarairIRmPmAuxiliaryAlarm10 | read-only | mandatory | Auxiliary #10 alarm (8600). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.102 | ScalarairIRmPmHotGasHeatingAlarm | read-only | mandatory | Hot gas heating alarm (8601). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.103 | ScalarairIRmPmEEV1PressureSensorError | read-only | mandatory | EEV1 pressure sensor error (8602). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.104 | ScalarairIRmPmEEV1TemperatureSensorError | read-only | mandatory | EEV1 temperature sensor error (8603). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.105 | ScalarairIRmPmEEV1StepperMotorError | read-only | mandatory | EEV1 stepper motor error (8604). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.106 | ScalarairIRmPmEEV2PressureSensorError | read-only | mandatory | EEV2 pressure sensor error (8605). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.107 | ScalarairIRmPmEEV2TemperatureSensorError | read-only | mandatory | EEV2 temperature sensor error (8606). |
| 1.3.6.1.4.1.318.1.1.13.5.3.43.108 | ScalarairIRmPmEEV2StepperMotorError | read-only | mandatory | EEV2 stepper motor error (8607). |
| 1.3.6.1.4.1.318.1.1.13.5.3.44 | NodeairIRmPmMyZone | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.44.1 | ScalarairIRmPmMyZoneNumber | read-only | mandatory | My zone number (11700). |
| 1.3.6.1.4.1.318.1.1.13.5.3.44.2 | NodeairIRmPmMyZoneRoomTemperature | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.44.2.1 | ScalarairIRmPmMyZoneRoomTemperatureC | read-only | mandatory | My zone room temperature in tenths of degrees Celsius (11701). |
| 1.3.6.1.4.1.318.1.1.13.5.3.44.2.2 | ScalarairIRmPmMyZoneRoomTemperatureF | read-only | mandatory | My zone room temperature in tenths of degrees Fahrenheit (11701). |
| 1.3.6.1.4.1.318.1.1.13.5.3.44.3 | ScalarairIRmPmMyZoneRoomHumidity | read-only | mandatory | My zone room humidity in tenths of %RH (11702). |
| 1.3.6.1.4.1.318.1.1.13.5.3.44.4 | NodeairIRmPmMyZoneSupplyTemperature | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.44.4.1 | ScalarairIRmPmMyZoneSupplyTemperatureC | read-only | mandatory | My zone supply temperature in tenths of degrees Celsius (11703). |
| 1.3.6.1.4.1.318.1.1.13.5.3.44.4.2 | ScalarairIRmPmMyZoneSupplyTemperatureF | read-only | mandatory | My zone supply temperature in tenths of degrees Fahrenheit (11703). |
| 1.3.6.1.4.1.318.1.1.13.5.3.44.5 | ScalarairIRmPmMyZoneSupplyHumidity | read-only | mandatory | My zone supply humidity in tenths of %RH (11704). |
| 1.3.6.1.4.1.318.1.1.13.5.3.44.6 | ScalarairIRmPmMyZoneSequencingTime | read-only | mandatory | My zone sequencing time in minutes (11705). |
| 1.3.6.1.4.1.318.1.1.13.5.3.44.7 | ScalarairIRmPmMyZoneNumberOfErrorUnits | read-only | mandatory | Number of error units in my zone (11706). |
| 1.3.6.1.4.1.318.1.1.13.5.3.44.8 | NodeairIRmPmMyZoneEmergencyTemperature | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.44.8.1 | ScalarairIRmPmMyZoneEmergencyTemperatureC | read-only | mandatory | My zone emergency temperature in tenths of degrees Celsius (11707). |
| 1.3.6.1.4.1.318.1.1.13.5.3.44.8.2 | ScalarairIRmPmMyZoneEmergencyTemperatureF | read-only | mandatory | My zone emergency temperature in tenths of degrees Fahrenheit (11707). |
| 1.3.6.1.4.1.318.1.1.13.5.3.44.9 | ScalarairIRmPmMyZoneCWEnergySaveMode | read-only | mandatory | My zone CW energy save mode (11708). |
| 1.3.6.1.4.1.318.1.1.13.5.3.45 | NodeairIRmPmGlobalZoneData | |||
| 1.3.6.1.4.1.318.1.1.13.5.3.45.1 | ScalarairIRmPmGlobalZoneDataEmergencyOpMode | read-only | mandatory | Emergency operation mode (11800). |
| 1.3.6.1.4.1.318.1.1.13.6 | NodeairIRGen3 | |||
| 1.3.6.1.4.1.318.1.1.13.6.1 | NodeairIRG3Ident | |||
| 1.3.6.1.4.1.318.1.1.13.6.1.1 | ScalarairIRG3IdentTableSize | read-only | mandatory | The ident table size. |
| 1.3.6.1.4.1.318.1.1.13.6.1.2 | TableairIRG3IdentTable | not-accessible | mandatory | Allows to get ident information of current RDU and its assigned CM's. |
| 1.3.6.1.4.1.318.1.1.13.6.1.2.1 | RowairIRG3IdentEntry | not-accessible | mandatory | The ident table entry. |
| 1.3.6.1.4.1.318.1.1.13.6.1.2.1.1 | ColumnairIRG3IdentIndex | read-only | mandatory | Index of ident table. |
| 1.3.6.1.4.1.318.1.1.13.6.1.2.1.2 | ColumnairIRG3IdentName | read-write | mandatory | A character string identifying the unit name. |
| 1.3.6.1.4.1.318.1.1.13.6.1.2.1.3 | ColumnairIRG3IdentLocation | read-write | mandatory | A character string identifying the unit location. |
| 1.3.6.1.4.1.318.1.1.13.6.1.2.1.4 | ColumnairIRG3IdentModelNumber | read-only | mandatory | A character string identifying the unit model number. |
| 1.3.6.1.4.1.318.1.1.13.6.1.2.1.5 | ColumnairIRG3IdentSerialNumber | read-only | mandatory | A character string identifying the unit serial number. |
| 1.3.6.1.4.1.318.1.1.13.6.1.2.1.6 | ColumnairIRG3IdentFirmwareRevision | read-only | mandatory | A character string identifying the unit firmware version. |
| 1.3.6.1.4.1.318.1.1.13.6.1.2.1.7 | ColumnairIRG3IdentHardwareRevision | read-only | mandatory | A character string identifying the unit controller hardware revision. |
| 1.3.6.1.4.1.318.1.1.13.6.1.2.1.8 | ColumnairIRG3IdentManufactureDate | read-only | mandatory | A character string identifying the unit manufacture date. |
| 1.3.6.1.4.1.318.1.1.13.6.1.2.1.9 | ColumnairIRG3IdentRDUSysOID | read-only | mandatory | This OID contains an OID path to the RDU data. |
| 1.3.6.1.4.1.318.1.1.13.6.1.2.1.10 | ColumnairIRG3IdentCMSysOID | read-only | mandatory | This OID contains an OID path to the cooling module data. |
| 1.3.6.1.4.1.318.1.1.13.6.1.2.1.11 | ColumnairIRG3IdentGroupSysOID | read-only | mandatory | This OID contains an OID path to the group data. |
| 1.3.6.1.4.1.318.1.1.13.6.2 | NodeairIRG3Group | |||
| 1.3.6.1.4.1.318.1.1.13.6.2.1 | ScalarairIRG3GroupTableSize | read-only | mandatory | The group table size. |
| 1.3.6.1.4.1.318.1.1.13.6.2.2 | TableairIRG3GroupStatusTable | not-accessible | mandatory | Allows to get group status information. |
| 1.3.6.1.4.1.318.1.1.13.6.2.2.1 | RowairIRG3GroupStatusEntry | not-accessible | mandatory | The group staus table entry. |
| 1.3.6.1.4.1.318.1.1.13.6.2.2.1.1 | ColumnairIRG3GroupStatusIndex | read-only | mandatory | Index of group status table. |
| 1.3.6.1.4.1.318.1.1.13.6.2.2.1.2 | ColumnairIRG3GroupStatusCoolOutput | read-only | mandatory | The group cooling output in tenths of kilowatts (kW). Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.2.2.1.3 | ColumnairIRG3GroupStatusCoolDemand | read-only | mandatory | The group cooling demand in tenths of kilowatts (kW). Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.2.2.1.4 | ColumnairIRG3GroupStatusAirFlowUS | read-only | mandatory | The group air flow in cubic feet per minute (CFM). Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.2.2.1.5 | ColumnairIRG3GroupStatusAirFlowMetric | read-only | mandatory | The group air flow in liters per second (L/s). Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.2.2.1.6 | ColumnairIRG3GroupStatusMaxRackInletTempUS | read-only | mandatory | The group maximum rack inlet temperature in tenths of degrees Fahrenheit. Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.2.2.1.7 | ColumnairIRG3GroupStatusMaxRackInletTempMetric | read-only | mandatory | The group maximum rack inlet temperature in tenths of degrees Celsius. Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.2.2.1.8 | ColumnairIRG3GroupStatusMinRackInletTempUS | read-only | mandatory | The group minimum rack inlet temperature in tenths of degrees Fahrenheit. Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.2.2.1.9 | ColumnairIRG3GroupStatusMinRackInletTempMetric | read-only | mandatory | The group minimum rack inlet temperature in tenths of degrees Celsius. Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.2.2.1.10 | ColumnairIRG3GroupStatusMaxReturnAirTempUS | read-only | mandatory | The group maximum return air temperature in tenths of degrees Fahrenheit. Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.2.2.1.11 | ColumnairIRG3GroupStatusMaxReturnAirTempMetric | read-only | mandatory | The group maximum return air temperature in tenths of degrees Celsius. Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.2.2.1.12 | ColumnairIRG3GroupStatusMinReturnAirTempUS | read-only | mandatory | The group minimum return air temperature in tenths of degrees Fahrenheit. Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.2.2.1.13 | ColumnairIRG3GroupStatusMinReturnAirTempMetric | read-only | mandatory | The group minimum return air temperature in tenths of degrees Celsius. Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.2.2.1.14 | ColumnairIRG3GroupStatusAvgSupplyTempUS | read-only | mandatory | The group average supply air temperature in tenths of degrees Fahrenheit. Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.2.2.1.15 | ColumnairIRG3GroupStatusAvgSupplyTempMetric | read-only | mandatory | The group average supply air temperature in tenths of degrees Celsius. Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.2.2.1.16 | ColumnairIRG3GroupStatusAvgReturnTempUS | read-only | mandatory | The group average return air temperature in tenths of degrees Fahrenheit. Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.2.2.1.17 | ColumnairIRG3GroupStatusAvgReturnTempMetric | read-only | mandatory | The group average return air temperature in tenths of degrees Celsius. Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.2.2.1.18 | ColumnairIRG3GroupStatusAvgFanSpeed | read-only | mandatory | The group average fan speed in revolutions per minute (RPM). Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.2.2.1.19 | ColumnairIRG3GroupStatusAvgAirFlowUS | read-only | mandatory | The group average air flow in cubic feet per minute (CFM). Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.2.2.1.20 | ColumnairIRG3GroupStatusAvgAirFlowMetric | read-only | mandatory | The group average air flow in liters per second (L/s). Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.2.2.1.21 | ColumnairIRG3GroupStatusTotalAirFlowUS | read-only | mandatory | The group total air flow in cubic feet per minute (CFM). Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.2.2.1.22 | ColumnairIRG3GroupStatusTotalAirFlowMetric | read-only | mandatory | The group total air flow in liters per second (L/s). Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.2.3 | TableairIRG3GroupSetpointsTable | not-accessible | mandatory | Allows to access the group setpoints. |
| 1.3.6.1.4.1.318.1.1.13.6.2.3.1 | RowairIRG3GroupSetpointsEntry | not-accessible | mandatory | The group setpoints table entry. |
| 1.3.6.1.4.1.318.1.1.13.6.2.3.1.1 | ColumnairIRG3GroupSetpointsIndex | read-only | mandatory | Index of group setpoints table. |
| 1.3.6.1.4.1.318.1.1.13.6.2.3.1.2 | ColumnairIRG3GroupSetpointsCoolSetpointUS | read-write | mandatory | Group cooling setpoint in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.6.2.3.1.3 | ColumnairIRG3GroupSetpointsCoolSetpointMetric | read-write | mandatory | Group cooling setpoint in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.6.2.3.1.4 | ColumnairIRG3GroupSetpointsCoolDeadbandUS | read-write | mandatory | Group cooling deadband in tenths of degrees Fahrenheit. Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.2.3.1.5 | ColumnairIRG3GroupSetpointsCoolDeadbandMetric | read-write | mandatory | Group cooling deadband in tenths of degrees Celsius. Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.2.3.1.6 | ColumnairIRG3GroupSetpointsFanSpeedPreference | read-write | mandatory | The group preferred fan speed setting. |
| 1.3.6.1.4.1.318.1.1.13.6.2.3.1.7 | ColumnairIRG3GroupSetpointsSupplyAirSetpointUS | read-write | mandatory | Group supply air setpoint in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.6.2.3.1.8 | ColumnairIRG3GroupSetpointsSupplyAirSetpointMetric | read-write | mandatory | Group supply air setpoint in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.6.2.3.1.9 | ColumnairIRG3GroupSetpointsAirFlowControl | read-write | mandatory | The group air flow control. |
| 1.3.6.1.4.1.318.1.1.13.6.2.3.1.10 | ColumnairIRG3GroupSetpointsLightingOnTime | read-write | mandatory | The group lighting on time in minutes. |
| 1.3.6.1.4.1.318.1.1.13.6.2.4 | TableairIRG3GroupConfigTable | not-accessible | mandatory | Allows to access group configuration table. |
| 1.3.6.1.4.1.318.1.1.13.6.2.4.1 | RowairIRG3GroupConfigEntry | not-accessible | mandatory | The group config table entry. |
| 1.3.6.1.4.1.318.1.1.13.6.2.4.1.1 | ColumnairIRG3GroupConfigIndex | read-only | mandatory | Index of group config table. |
| 1.3.6.1.4.1.318.1.1.13.6.2.4.1.2 | ColumnairIRG3GroupConfigNumberofCoolingUnits | read-write | mandatory | The number of cooling units. |
| 1.3.6.1.4.1.318.1.1.13.6.2.4.1.3 | ColumnairIRG3GroupConfigConfigurationType | read-write | mandatory | The group configuration type. The spot configuration type is not supported. Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.2.4.1.4 | ColumnairIRG3GroupConfigCapacityControlType | read-write | mandatory | The group capacity control. Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.2.4.1.5 | ColumnairIRG3GroupConfigFanSpeedControl | read-write | mandatory | The group fan speed control. |
| 1.3.6.1.4.1.318.1.1.13.6.2.4.1.6 | ColumnairIRG3GroupConfigCoolGainP | read-write | mandatory | The gain component of the PID in hundredths. |
| 1.3.6.1.4.1.318.1.1.13.6.2.4.1.7 | ColumnairIRG3GroupConfigCoolResetRateI | read-write | mandatory | The integral component of the PID in hundredths. |
| 1.3.6.1.4.1.318.1.1.13.6.2.4.1.8 | ColumnairIRG3GroupConfigCoolDerivativeD | read-write | mandatory | The derivative component of the PID in hundredths. |
| 1.3.6.1.4.1.318.1.1.13.6.2.4.1.9 | ColumnairIRG3GroupConfigCoolPIDReset | read-write | mandatory | Will reset the PID coefficients back to the factory defaults. Readback is not supported, returns -1. |
| 1.3.6.1.4.1.318.1.1.13.6.2.4.1.10 | ColumnairIRG3GroupConfigNumberofBackupUnits | read-write | mandatory | The number of backup units. |
| 1.3.6.1.4.1.318.1.1.13.6.2.4.1.11 | ColumnairIRG3GroupConfigRuntimeBalancingEnable | read-write | mandatory | Enable or disable runtime balancing feature. |
| 1.3.6.1.4.1.318.1.1.13.6.2.4.1.12 | ColumnairIRG3GroupConfigLoadAssistEnable | read-write | mandatory | Enable or disable load assist feature. |
| 1.3.6.1.4.1.318.1.1.13.6.3 | NodeairIRG3Alarms | |||
| 1.3.6.1.4.1.318.1.1.13.6.3.1 | ScalarairIRG3AlarmsTableSize | read-only | mandatory | The number of active alarms in the airIRG3AlarmsTable. |
| 1.3.6.1.4.1.318.1.1.13.6.3.2 | TableairIRG3AlarmsTable | not-accessible | mandatory | Table of active alarms for the device. |
| 1.3.6.1.4.1.318.1.1.13.6.3.2.1 | RowairIRG3AlarmsEntry | not-accessible | mandatory | Alarms specification |
| 1.3.6.1.4.1.318.1.1.13.6.3.2.1.1 | ColumnairIRG3AlarmsIndex | read-only | mandatory | Alarm index. |
| 1.3.6.1.4.1.318.1.1.13.6.3.2.1.2 | ColumnairIRG3AlarmsEventCode | read-only | mandatory | Event Code for the alarm. Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.3.2.1.3 | ColumnairIRG3AlarmsDescription | read-only | mandatory | Description of the alarm. Returns (-1) if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.4 | NodeairIRG3RDU | |||
| 1.3.6.1.4.1.318.1.1.13.6.4.1 | ScalarairIRG3RDUTableSize | read-only | mandatory | The RDU table size. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2 | TableairIRG3RDUStatusTable | not-accessible | mandatory | Allows to access RDU status table. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1 | RowairIRG3RDUStatusEntry | not-accessible | mandatory | The RDU status table entry. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.1 | ColumnairIRG3RDUStatusDeviceIndex | read-only | mandatory | Index of RDU status table. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.2 | ColumnairIRG3RDUID | read-only | mandatory | The current RDU ID (1 to F). Configured RDU only shall display ID, else return -1. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.3 | ColumnairIRG3RDUStatusOnReadyStandby | read-only | mandatory | The RDU current status. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.4 | ColumnairIRG3RDUStatusOperatingMode | read-only | mandatory | The RDU actual operating mode. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.5 | ColumnairIRG3RDUStatusLeadPump | read-only | mandatory | The RDU lead pump. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.6 | ColumnairIRG3RDUStatusStartupDelay | read-only | mandatory | The RDU start up delay in seconds. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.7 | ColumnairIRG3RDUStatusPumpChangeOverInterval | read-only | mandatory | The RDU pump change over interval in days. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.8 | ColumnairIRG3RDUStatusStopOnLeakDetect | read-only | mandatory | The RDU status of stop on leak detect. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.9 | ColumnairIRG3RDUStatusPowerSource | read-only | mandatory | The RDU power source status. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.10 | ColumnairIRG3RDUStatusTotalRDUOutputPower | read-only | mandatory | The RDU output power in tenths of kilowatts (kW). |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.11 | ColumnairIRG3RDUStatusInletWaterTempUS | read-only | mandatory | The RDU inlet water temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.12 | ColumnairIRG3RDUStatusInletWaterTempMetric | read-only | mandatory | The RDU inlet water temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.13 | ColumnairIRG3RDUStatusOutletWaterTempUS | read-only | mandatory | The RDU outlet water temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.14 | ColumnairIRG3RDUStatusOutletWaterTempMetric | read-only | mandatory | The RDU outlet water temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.15 | ColumnairIRG3RDUStatusCondenserSaturationTempUS | read-only | mandatory | The RDU condenser saturation temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.16 | ColumnairIRG3RDUStatusCondenserSaturationTempMetric | read-only | mandatory | The RDU condenser saturation temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.17 | ColumnairIRG3RDUStatusDewPointTempUS | read-only | mandatory | The RDU dew point temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.18 | ColumnairIRG3RDUStatusDewPointTempMetric | read-only | mandatory | The RDU dew point temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.19 | ColumnairIRG3RDUStatusPumpOutletTempUS | read-only | mandatory | The RDU pump outlet temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.20 | ColumnairIRG3RDUStatusPumpOutletTempMetric | read-only | mandatory | The RDU pump outlet temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.21 | ColumnairIRG3RDUStatusSubcoolerOutletTempUS | read-only | mandatory | The RDU sub cooler outlet temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.22 | ColumnairIRG3RDUStatusSubcoolerOutletTempMetric | read-only | mandatory | The RDU sub cooler outlet temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.23 | ColumnairIRG3RDUStatusCondenserOutletTempUS | read-only | mandatory | The RDU condenser outlet temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.24 | ColumnairIRG3RDUStatusCondenserOutletTempMetric | read-only | mandatory | The RDU condenser outlet temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.25 | ColumnairIRG3RDUStatusCondenserInletTempUS | read-only | mandatory | The RDU condenser inlet temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.26 | ColumnairIRG3RDUStatusCondenserInletTempMetric | read-only | mandatory | The RDU condenser inlet temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.27 | ColumnairIRG3RDUStatusCondenserOutletPressureUS | read-only | mandatory | The RDU condenser outlet pressure in pounds per square inch (PSI). |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.28 | ColumnairIRG3RDUStatusCondenserOutletPressureMetric | read-only | mandatory | The RDU condenser outlet pressure in kiloPascals (KPa). |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.29 | ColumnairIRG3RDUStatusPump1HeadPressureUS | read-only | mandatory | The RDU Pump 1 head pressure in pounds per square inch (PSI). |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.30 | ColumnairIRG3RDUStatusPump1HeadPressureMetric | read-only | mandatory | The RDU Pump 1 head pressure in kiloPascals (KPa). |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.31 | ColumnairIRG3RDUStatusPump2HeadPressureUS | read-only | mandatory | The RDU Pump 2 head pressure in pounds per square inch (PSI). |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.32 | ColumnairIRG3RDUStatusPump2HeadPressureMetric | read-only | mandatory | The RDU Pump 2 head pressure in kiloPascals (KPa). |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.33 | ColumnairIRG3RDUStatusPump1Speed | read-only | mandatory | The RDU Pump 1 speed in revolutions per minute (RPM). |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.34 | ColumnairIRG3RDUStatusPump2Speed | read-only | mandatory | The RDU Pump 2 speed in revolutions per minute (RPM). |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.35 | ColumnairIRG3RDUStatusCWValvePosition | read-only | mandatory | The RDU CW Valve position in % open |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.36 | ColumnairIRG3RDUStatusReceiverLiquidLevel | read-only | mandatory | The RDU receiver liquid level in % Full |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.37 | ColumnairIRG3RDUStatusDCPowerSupply1Current | read-only | mandatory | The RDU DC Power Supply 1 Current in Amps |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.38 | ColumnairIRG3RDUStatusDCPowerSupply2Current | read-only | mandatory | The RDU DC Power Supply 2 Current in Amps |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.39 | ColumnairIRG3RDUStatusTotalDCPowerSupplyCurrent | read-only | mandatory | The RDU Total DC Power Supply Current in Amps |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.40 | ColumnairIRG3RDUStatusInputState | read-only | mandatory | The RDU Input state. |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.41 | ColumnairIRG3RDUStatusOutputState | read-only | mandatory | The RDU Output state |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.42 | ColumnairIRG3RDUStatusByPassValvePosition | read-only | mandatory | The RDU By Pass Valve position in % open |
| 1.3.6.1.4.1.318.1.1.13.6.4.2.1.43 | ColumnairIRG3RDUStatusRefrigerantLeakDetector | read-only | mandatory | The RDU refrigerant leak detector status. |
| 1.3.6.1.4.1.318.1.1.13.6.4.3 | TableairIRG3RDURunHoursTable | not-accessible | mandatory | Allows to access RDU run hours table. |
| 1.3.6.1.4.1.318.1.1.13.6.4.3.1 | RowairIRG3RDURunHoursEntry | not-accessible | mandatory | The RDU run hours table entry. |
| 1.3.6.1.4.1.318.1.1.13.6.4.3.1.1 | ColumnairIRG3RDURunHoursDeviceIndex | read-only | mandatory | Index of RDU run hours table. |
| 1.3.6.1.4.1.318.1.1.13.6.4.3.1.2 | ColumnairIRG3RDURunHoursRDUID | read-only | mandatory | The current RDU ID (1 to F). Configured RDU only shall display ID, else return -1. |
| 1.3.6.1.4.1.318.1.1.13.6.4.3.1.3 | ColumnairIRG3RDURunHoursPump1 | read-only | mandatory | The RDU run hours of Pump 1. |
| 1.3.6.1.4.1.318.1.1.13.6.4.3.1.4 | ColumnairIRG3RDURunHoursPump2 | read-only | mandatory | The RDU run hours of Pump 2. |
| 1.3.6.1.4.1.318.1.1.13.6.4.3.1.5 | ColumnairIRG3RDURunHoursPowerSupply1 | read-only | mandatory | The RDU run hours of power supply 1. |
| 1.3.6.1.4.1.318.1.1.13.6.4.3.1.6 | ColumnairIRG3RDURunHoursPowerSupply2 | read-only | mandatory | The RDU run hours of power supply 2. |
| 1.3.6.1.4.1.318.1.1.13.6.4.4 | TableairIRG3RDUServiceIntervalsTable | not-accessible | mandatory | Allows to access RDU service intervals table. |
| 1.3.6.1.4.1.318.1.1.13.6.4.4.1 | RowairIRG3RDUServiceIntervalsEntry | not-accessible | mandatory | The service interval table entry. |
| 1.3.6.1.4.1.318.1.1.13.6.4.4.1.1 | ColumnairIRG3RDUServiceIntervalsDeviceIndex | read-only | mandatory | Index of service interval table. |
| 1.3.6.1.4.1.318.1.1.13.6.4.4.1.2 | ColumnairIRG3RDUServiceIntervalsRDUID | read-only | mandatory | The current RDU ID (1 to F). Configured RDU only shall display ID, else return -1. |
| 1.3.6.1.4.1.318.1.1.13.6.4.4.1.3 | ColumnairIRG3RDUServiceIntervalsAirFilterInterval | read-write | mandatory | The RDU service interval for air filter in hours. Returns -1 if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.4.4.1.4 | ColumnairIRG3RDUServiceIntervalsAirFilterAlarm | read-write | mandatory | The RDU service interval air filter alarm status. Returns -1 if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.4.5 | TableairIRG3RDUThresholdsTable | not-accessible | mandatory | Allows to access RDU thresholds table. |
| 1.3.6.1.4.1.318.1.1.13.6.4.5.1 | RowairIRG3RDUThresholdsEntry | not-accessible | mandatory | The RDU thresholds table entry. |
| 1.3.6.1.4.1.318.1.1.13.6.4.5.1.1 | ColumnairIRG3RDUThresholdsDeviceIndex | read-only | mandatory | Index of RDU thresholds table. |
| 1.3.6.1.4.1.318.1.1.13.6.4.5.1.2 | ColumnairIRG3RDUThresholdsRDUID | read-only | mandatory | The current RDU ID (1 to F). Configured RDU only shall display ID, else return -1. |
| 1.3.6.1.4.1.318.1.1.13.6.4.5.1.3 | ColumnairIRG3RDUThresholdsEnteringFluidTempHighUS | read-write | mandatory | The RDU threshold for entering fluid temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.6.4.5.1.4 | ColumnairIRG3RDUThresholdsEnteringFluidTempHighMetric | read-write | mandatory | The RDU threshold for entering fluid temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.6.4.6 | TableairIRG3RDUSetpointsTable | not-accessible | mandatory | Allows to access RDU set points table. |
| 1.3.6.1.4.1.318.1.1.13.6.4.6.1 | RowairIRG3RDUSetpointsEntry | not-accessible | mandatory | The RDU set points table entry. |
| 1.3.6.1.4.1.318.1.1.13.6.4.6.1.1 | ColumnairIRG3RDUSetpointsDeviceIndex | read-only | mandatory | Index of RDU set points table. |
| 1.3.6.1.4.1.318.1.1.13.6.4.7 | TableairIRG3RDUConfigTable | not-accessible | mandatory | Allows to access RDU configuration table. |
| 1.3.6.1.4.1.318.1.1.13.6.4.7.1 | RowairIRG3RDUConfigEntry | not-accessible | mandatory | The RDU configuration table entry. |
| 1.3.6.1.4.1.318.1.1.13.6.4.7.1.1 | ColumnairIRG3RDUConfigDeviceIndex | read-only | mandatory | Index of RDU configuration table. |
| 1.3.6.1.4.1.318.1.1.13.6.4.7.1.2 | ColumnairIRG3RDUConfigRDUID | read-only | mandatory | The current RDU ID (1 to F). Configured RDU only shall display ID, else return -1. |
| 1.3.6.1.4.1.318.1.1.13.6.4.7.1.3 | ColumnairIRG3RDUConfigStopOnLeakDetect | read-write | mandatory | The RDU stop on leak detect set. |
| 1.3.6.1.4.1.318.1.1.13.6.4.7.1.4 | ColumnairIRG3RDUConfigStartupDelay | read-write | mandatory | The RDU start up delay in seconds. |
| 1.3.6.1.4.1.318.1.1.13.6.4.7.1.5 | ColumnairIRG3RDUConfigPumpChangeOverInterval | read-write | mandatory | The RDU pump change over interval in days. |
| 1.3.6.1.4.1.318.1.1.13.6.4.7.1.6 | ColumnairIRG3RDUConfigPowerSource | read-write | mandatory | The RDU power source. |
| 1.3.6.1.4.1.318.1.1.13.6.4.7.1.7 | ColumnairIRG3RDUConfigOutputSource | read-write | mandatory | The RDU output source. |
| 1.3.6.1.4.1.318.1.1.13.6.4.7.1.8 | ColumnairIRG3RDUConfigInputNormalState | read-write | mandatory | The RDU Input Normal State. |
| 1.3.6.1.4.1.318.1.1.13.6.4.7.1.9 | ColumnairIRG3RDUConfigOutputNormalState | read-write | mandatory | The RDU Output Normal State. |
| 1.3.6.1.4.1.318.1.1.13.6.4.7.1.10 | ColumnairIRG3RDUConfigByPassValveEnabled | read-write | mandatory | The RDU By Pass Valve Enabled State. |
| 1.3.6.1.4.1.318.1.1.13.6.4.7.1.11 | ColumnairIRG3RDUConfigRefrigerantLeakDetectorEnabled | read-write | mandatory | The RDU Refrigerant Leak Detector Enabled State. |
| 1.3.6.1.4.1.318.1.1.13.6.4.7.1.12 | ColumnairIRG3RDUConfigCalibrateRefrigerantLeakDetector | read-write | mandatory | This parameter allows to calibrate the RDU Refrigerant Leak Detector and is write only. The read returns -1. Only 'yes' is supported. |
| 1.3.6.1.4.1.318.1.1.13.6.4.7.1.13 | ColumnairIRG3RDUConfigOnReadyStandby | read-write | mandatory | This parameter allows to configure RDU on/standby parameter. Ready is currently not supported. If unsupported returns -1. |
| 1.3.6.1.4.1.318.1.1.13.6.5 | NodeairIRG3CM | |||
| 1.3.6.1.4.1.318.1.1.13.6.5.1 | ScalarairIRG3CMTableSize | read-only | mandatory | The cooling module table size. |
| 1.3.6.1.4.1.318.1.1.13.6.5.2 | TableairIRG3CMStatusTable | not-accessible | mandatory | Allows to access CM status table. |
| 1.3.6.1.4.1.318.1.1.13.6.5.2.1 | RowairIRG3CMStatusEntry | not-accessible | mandatory | The CM status table entry. |
| 1.3.6.1.4.1.318.1.1.13.6.5.2.1.1 | ColumnairIRG3CMStatusDeviceIndex | read-only | mandatory | Index of CM status table. |
| 1.3.6.1.4.1.318.1.1.13.6.5.2.1.2 | ColumnairIRG3CMStatusCMID | read-only | mandatory | The CM ID (RDU Number - Group Number - CM Unit Number). |
| 1.3.6.1.4.1.318.1.1.13.6.5.2.1.3 | ColumnairIRG3CMStatusOperatingMode | read-only | mandatory | The current operating mode of the CM. |
| 1.3.6.1.4.1.318.1.1.13.6.5.2.1.4 | ColumnairIRG3CMStatusUnitType | read-only | mandatory | The current CM unit type. |
| 1.3.6.1.4.1.318.1.1.13.6.5.2.1.5 | ColumnairIRG3CMStatusRackInletTempUS | read-only | mandatory | The CM rack inlet temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.6.5.2.1.6 | ColumnairIRG3CMStatusRackInletTempMetric | read-only | mandatory | The CM rack inlet temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.6.5.2.1.7 | ColumnairIRG3CMStatusReturnAirTempUS | read-only | mandatory | The CM return air temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.6.5.2.1.8 | ColumnairIRG3CMStatusReturnAirTempMetric | read-only | mandatory | The CM return air temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.6.5.2.1.9 | ColumnairIRG3CMStatusLiquidTempUS | read-only | mandatory | The CM liquid temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.6.5.2.1.10 | ColumnairIRG3CMStatusLiquidTempMetric | read-only | mandatory | The CM liquid temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.6.5.2.1.11 | ColumnairIRG3CMStatusVaporTempUS | read-only | mandatory | The CM vapor temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.6.5.2.1.12 | ColumnairIRG3CMStatusVaporTempMetric | read-only | mandatory | The CM vapor temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.6.5.2.1.13 | ColumnairIRG3CMStatusEvaporatorTempUS | read-only | mandatory | The CM saturation temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.6.5.2.1.14 | ColumnairIRG3CMStatusEvaporatorTempMetric | read-only | mandatory | The CM saturation temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.6.5.2.1.15 | ColumnairIRG3CMStatusLiquidInletPressureUS | read-only | mandatory | The CM Liquid Inlet pressure in pounds per square inch (PSI). |
| 1.3.6.1.4.1.318.1.1.13.6.5.2.1.16 | ColumnairIRG3CMStatusLiquidInletPressureMetric | read-only | mandatory | The CM Liquid Inlet pressure in kiloPascals (kPa). |
| 1.3.6.1.4.1.318.1.1.13.6.5.2.1.17 | ColumnairIRG3CMStatusVaporOutletPressureUS | read-only | mandatory | The CM Vapor Outlet pressure in pounds per square inch (PSI). |
| 1.3.6.1.4.1.318.1.1.13.6.5.2.1.18 | ColumnairIRG3CMStatusVaporOutletPressureMetric | read-only | mandatory | The CM Vapor Outlet pressure in kiloPascals (kPa). |
| 1.3.6.1.4.1.318.1.1.13.6.5.2.1.19 | ColumnairIRG3CMStatusExpansionValvePosition | read-only | mandatory | The CM expansion valve position in % open |
| 1.3.6.1.4.1.318.1.1.13.6.5.2.1.20 | ColumnairIRG3CMStatusEPRValvePosition | read-only | mandatory | The CM Evaporator Pressure Regulator Valve Position in tenths of percent open |
| 1.3.6.1.4.1.318.1.1.13.6.5.2.1.21 | ColumnairIRG3CMStatusLocalDisplayOnOffEnabled | read-only | mandatory | The status of the on/off control on the CM local display. |
| 1.3.6.1.4.1.318.1.1.13.6.5.2.1.22 | ColumnairIRG3CMStatusAverageFanSpeed | read-only | mandatory | The CM Average Fan Speed. |
| 1.3.6.1.4.1.318.1.1.13.6.5.3 | TableairIRG3CMRunHoursTable | not-accessible | mandatory | Allows to access CM run hours table. |
| 1.3.6.1.4.1.318.1.1.13.6.5.3.1 | RowairIRG3CMRunHoursEntry | not-accessible | mandatory | The CM run hours table entry. |
| 1.3.6.1.4.1.318.1.1.13.6.5.3.1.1 | ColumnairIRG3CMRunHoursDeviceIndex | read-only | mandatory | Index of CM run hours table. |
| 1.3.6.1.4.1.318.1.1.13.6.5.3.1.2 | ColumnairIRG3CMRunHoursCMID | read-only | mandatory | The CM ID (RDU Number - Group Number - CM Unit Number). |
| 1.3.6.1.4.1.318.1.1.13.6.5.3.1.3 | ColumnairIRG3CMRunHoursFan1 | read-only | mandatory | The CM run hours for Fan1. Returns (-1) if not appilcable. |
| 1.3.6.1.4.1.318.1.1.13.6.5.3.1.4 | ColumnairIRG3CMRunHoursFan2 | read-only | mandatory | The CM run hours for Fan2. Returns (-1) if not appilcable. |
| 1.3.6.1.4.1.318.1.1.13.6.5.3.1.5 | ColumnairIRG3CMRunHoursFan3 | read-only | mandatory | The CM run hours for Fan3. Returns (-1) if not appilcable. |
| 1.3.6.1.4.1.318.1.1.13.6.5.3.1.6 | ColumnairIRG3CMRunHoursFan4 | read-only | mandatory | The CM run hours for Fan4. Returns (-1) if not appilcable. |
| 1.3.6.1.4.1.318.1.1.13.6.5.3.1.7 | ColumnairIRG3CMRunHoursFan5 | read-only | mandatory | The CM run hours for Fan5. Returns (-1) if not appilcable. |
| 1.3.6.1.4.1.318.1.1.13.6.5.3.1.8 | ColumnairIRG3CMRunHoursAirFilter | read-only | mandatory | The CM run hours for air filter. |
| 1.3.6.1.4.1.318.1.1.13.6.5.4 | TableairIRG3CMServiceIntervalsTable | not-accessible | mandatory | Allows to access CM service intervals table. |
| 1.3.6.1.4.1.318.1.1.13.6.5.4.1 | RowairIRG3CMServiceIntervalsEntry | not-accessible | mandatory | The CM service interval table entry. |
| 1.3.6.1.4.1.318.1.1.13.6.5.4.1.1 | ColumnairIRG3CMServiceIntervalsDeviceIndex | read-only | mandatory | Index of CM service intervals table. |
| 1.3.6.1.4.1.318.1.1.13.6.5.4.1.2 | ColumnairIRG3CMServiceIntervalsCMID | read-only | mandatory | The CM ID (RDU Number - Group Number - CM Unit Number). |
| 1.3.6.1.4.1.318.1.1.13.6.5.4.1.3 | ColumnairIRG3CMServiceIntervalsAirFilterInterval | read-write | mandatory | The CM service interval for air filter in weeks. Supported only for RA. Returns -1 if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.5.4.1.4 | ColumnairIRG3CMServiceIntervalsAirFilterAlarm | read-write | mandatory | The CM service interval air filter alarm status. Supported only for RA. Returns -1 if not supported. |
| 1.3.6.1.4.1.318.1.1.13.6.5.5 | TableairIRG3CMThresholdsTable | not-accessible | mandatory | Allows to access CM thresholds table. |
| 1.3.6.1.4.1.318.1.1.13.6.5.5.1 | RowairIRG3CMThresholdsEntry | not-accessible | mandatory | The CM thresholds table entry. |
| 1.3.6.1.4.1.318.1.1.13.6.5.5.1.1 | ColumnairIRG3CMThresholdsDeviceIndex | read-only | mandatory | Index for CM thresholds table. |
| 1.3.6.1.4.1.318.1.1.13.6.5.5.1.2 | ColumnairIRG3CMThresholdsCMID | read-only | mandatory | The CM ID (RDU Number - Group Number - CM Unit Number). |
| 1.3.6.1.4.1.318.1.1.13.6.5.5.1.3 | ColumnairIRG3CMThresholdsRackInletTempHighUS | read-write | mandatory | The CM high threshold for rack inlet temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.6.5.5.1.4 | ColumnairIRG3CMThresholdsRackInletTempHighMetric | read-write | mandatory | The CM high threshold for rack inlet temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.6.5.5.1.5 | ColumnairIRG3CMThresholdsSupplyAirTempHighUS | read-write | mandatory | The CM high threshold for supply air temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.6.5.5.1.6 | ColumnairIRG3CMThresholdsSupplyAirTempHighMetric | read-write | mandatory | The CM high threshold for supply air temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.6.5.5.1.7 | ColumnairIRG3CMThresholdsReturnAirTempHighUS | read-write | mandatory | The CM high threshold for return air temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.13.6.5.5.1.8 | ColumnairIRG3CMThresholdsReturnAirTempHighMetric | read-write | mandatory | The CM high threshold for return air temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.13.6.5.6 | TableairIRG3CMSetpointsTable | not-accessible | mandatory | Allows to access CM set points table. |
| 1.3.6.1.4.1.318.1.1.13.6.5.6.1 | RowairIRG3CMSetpointsEntry | not-accessible | mandatory | The CM set points table entry. |
| 1.3.6.1.4.1.318.1.1.13.6.5.6.1.1 | ColumnairIRG3CMSetpointsDeviceIndex | read-only | mandatory | Index of CM set points table. |
| 1.3.6.1.4.1.318.1.1.13.6.5.7 | TableairIRG3CMConfigTable | not-accessible | mandatory | Allows to access CM configuration table. |
| 1.3.6.1.4.1.318.1.1.13.6.5.7.1 | RowairIRG3CMConfigEntry | not-accessible | mandatory | The CM configuration table entry. |
| 1.3.6.1.4.1.318.1.1.13.6.5.7.1.1 | ColumnairIRG3CMConfigDeviceIndex | read-only | mandatory | Index of CM configuration table. |
| 1.3.6.1.4.1.318.1.1.13.6.5.7.1.2 | ColumnairIRG3CMConfigCMID | read-only | mandatory | The CM ID (RDU Number - Group Number - CM Unit Number). |
| 1.3.6.1.4.1.318.1.1.13.6.5.7.1.3 | ColumnairIRG3CMConfigStopOnCoolFail | read-write | mandatory | Enable/Disable Stop On cool fail. When enabled, stops the unit if it detects that it is blowing warm air into the cold aisle. |
| 1.3.6.1.4.1.318.1.1.13.6.5.7.1.4 | ColumnairIRG3CMConfigStartupDelay | read-write | mandatory | The CM start up delay in seconds. |
| 1.3.6.1.4.1.318.1.1.13.6.5.7.1.5 | ColumnairIRG3CMConfigRemoteOnStandby | read-write | mandatory | The CM configuration for operating mode. |
| 1.3.6.1.4.1.318.1.1.13.6.5.7.1.6 | ColumnairIRG3CMConfigPowerSource | read-write | mandatory | The CM power source. |
| 1.3.6.1.4.1.318.1.1.14 | NoderARU | |||
| 1.3.6.1.4.1.318.1.1.14.1 | NoderARUIdent | |||
| 1.3.6.1.4.1.318.1.1.14.1.1 | TablerARUIdentTable | not-accessible | mandatory | Allows for query of the individual devices. The number of entries is contained in the rARUStatusAruDeviceCount OID. |
| 1.3.6.1.4.1.318.1.1.14.1.1.1 | RowrARUIdentEntry | not-accessible | mandatory | The device to query. |
| 1.3.6.1.4.1.318.1.1.14.1.1.1.1 | ColumnrARUIdentAruIndex | read-only | mandatory | The index to the ARU entry. |
| 1.3.6.1.4.1.318.1.1.14.1.1.1.2 | ColumnrARUIdentName | read-only | mandatory | A character string identifying the device. |
| 1.3.6.1.4.1.318.1.1.14.2 | NoderARUConfig | |||
| 1.3.6.1.4.1.318.1.1.14.2.1 | TablerARUConfigTable | not-accessible | mandatory | Allows for configuration of the individual ARU devices accessible from this IP address. The number of entries is contained in the rARUStatusAruDeviceCount OID. |
| 1.3.6.1.4.1.318.1.1.14.2.1.1 | RowrARUConfigEntry | not-accessible | mandatory | The ARUs to configure. |
| 1.3.6.1.4.1.318.1.1.14.2.1.1.1 | ColumnrARUConfigAruIndex | read-only | mandatory | The index to the ARU entry. |
| 1.3.6.1.4.1.318.1.1.14.2.1.1.2 | ColumnrARUConfigAruName | read-write | mandatory | The name of the ARU. |
| 1.3.6.1.4.1.318.1.1.14.2.1.1.3 | ColumnrARUConfigAruRemoteSetpoint | read-write | mandatory | This OID defines the desired base airflow of the ARU, and sets the speed of the ARU fans when the temperature override is inactive. Values specified in cfm (cu… |
| 1.3.6.1.4.1.318.1.1.14.2.1.1.4 | ColumnrARUConfigAruTempOvrdEnableDisable | read-write | mandatory | This OID is used to enable/disable the remote temperature override setting of the ARU. If this OID is set to 1, the remote setting for temperature override is … |
| 1.3.6.1.4.1.318.1.1.14.2.1.1.5 | ColumnrARUConfigAruTempOvrdSetpoint | read-write | mandatory | This OID is the Temperature Override setpoint of the ARU. NOTE: -1 will be returned if the ARU is not communicating. Values are represented in whole number deg… |
| 1.3.6.1.4.1.318.1.1.14.2.1.1.6 | ColumnrARUConfigAruMasterControl | read-write | mandatory | This is the master on/off control for the ARU. |
| 1.3.6.1.4.1.318.1.1.14.3 | NoderARUStatus | |||
| 1.3.6.1.4.1.318.1.1.14.3.1 | ScalarrARUStatusAruDeviceCount | read-only | mandatory | The total number of ARUs accessible from this IP. |
| 1.3.6.1.4.1.318.1.1.14.3.2 | ScalarrARUStatusSysTempUnits | read-only | mandatory | The temperature scale used to display the temperature in the system, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration… |
| 1.3.6.1.4.1.318.1.1.14.3.3 | TablerARUStatusTable | not-accessible | mandatory | Allows for query of the individual ARUs accessible from this IP address. The number of entries is contained in the rARUStatusAruDeviceCount OID. |
| 1.3.6.1.4.1.318.1.1.14.3.3.1 | RowrARUStatusEntry | not-accessible | mandatory | The ARUs to access. |
| 1.3.6.1.4.1.318.1.1.14.3.3.1.1 | ColumnrARUStatusAruIndex | read-only | mandatory | The index to the ARU entry. |
| 1.3.6.1.4.1.318.1.1.14.3.3.1.2 | ColumnrARUStatusAruName | read-only | mandatory | The name of the ARU. |
| 1.3.6.1.4.1.318.1.1.14.3.3.1.3 | ColumnrARUStatusAruRemoteSetpoint | read-only | mandatory | This OID defines the desired base airflow of the ARU, or the speed of the ARU fans when the temperature override is inactive. See also the rARUConfigAruRemoteS… |
| 1.3.6.1.4.1.318.1.1.14.3.3.1.4 | ColumnrARUStatusAruManualSetpoint | read-only | mandatory | Manual operating setpoint of the ARU, which is set on the panel of the ARU. If the ARU doesn't have a manual , the OID will always return a value of aruRem (10… |
| 1.3.6.1.4.1.318.1.1.14.3.3.1.5 | ColumnrARUStatusAruTemp1 | read-only | mandatory | ARU temperature probe #1 reading. The summary exhaust temperature on 2nd generation ARUs. NOTE: -1 will be returned if the ARU is not communicating. Values are… |
| 1.3.6.1.4.1.318.1.1.14.3.3.1.6 | ColumnrARUStatusAruTemp2 | read-only | mandatory | ARU temperature probe #2 reading. The exhaust temperature in the upper plenum on 2nd generation ARUs. NOTE: -1 will be returned if the ARU is not communicating… |
| 1.3.6.1.4.1.318.1.1.14.3.3.1.7 | ColumnrARUStatusAruTemp3 | read-only | mandatory | ARU temperature probe #3 reading. The exhaust temperature in the lower plenum on 2nd generation ARUs. NOTE: -1 will be returned if the ARU is not communicating… |
| 1.3.6.1.4.1.318.1.1.14.3.3.1.8 | ColumnrARUStatusAruTempOvrdEnableDisable | read-only | mandatory | This OID indicates whether the ARU remote temperature override is enabled or disabled. If this OID is a 1, the remote setting for temperature override is disab… |
| 1.3.6.1.4.1.318.1.1.14.3.3.1.9 | ColumnrARUStatusAruTempOvrdSetpoint | read-only | mandatory | ARU remote temperature override setpoint setting. NOTE: -1 will be returned if the ARU is not communicating. Values are represented in whole number degrees. Un… |
| 1.3.6.1.4.1.318.1.1.14.3.3.1.10 | ColumnrARUStatusAruAlarmState | read-only | mandatory | An ASCII string containing the 8 flags representing the current alarm state of the ARU. If the state of the ARU is unknown, this variable is set to 'UNKNOWN'. … |
| 1.3.6.1.4.1.318.1.1.14.3.3.1.11 | ColumnrARUStatusAruCommStatus | read-only | mandatory | The state of communications to the device. commNeverDiscovered(1) indicates there has never been communications with this device. commsEstablished(2) indicates… |
| 1.3.6.1.4.1.318.1.1.14.3.3.1.12 | ColumnrARUStatusAruTempOvrdStatus | read-only | mandatory | Specifies whether the ARU is increasing airflow because exhaust air temperature has exceeded the setting specified in the rARUConfigAruTempOvrdSetpoint OID. |
| 1.3.6.1.4.1.318.1.1.14.3.3.1.13 | ColumnrARUStatusAruMasterControl | read-only | mandatory | This is the master on/off control for the ARU. |
| 1.3.6.1.4.1.318.1.1.14.3.3.1.14 | ColumnrARUStatusAruTotalAirflow | read-only | mandatory | The total airflow provided by the aru. Specified in cfm (cubic feet per minute). Can be converted to metric values using the conversion factor: 1 cfm = 1.70 m^… |
| 1.3.6.1.4.1.318.1.1.14.4 | NoderARUFanStatus | |||
| 1.3.6.1.4.1.318.1.1.14.4.1 | TablerARUFanStatusTable | not-accessible | mandatory | Allows for query of the individual devices. The number of entries is contained in the rARUStatusAruDeviceCount OID. |
| 1.3.6.1.4.1.318.1.1.14.4.1.1 | RowrARUFanStatusEntry | not-accessible | mandatory | The device to query. |
| 1.3.6.1.4.1.318.1.1.14.4.1.1.1 | ColumnrARUFanStatusAruIndex | read-only | mandatory | The index to the ARU entry. |
| 1.3.6.1.4.1.318.1.1.14.4.1.1.2 | ColumnrARUFanStatusNominalFanSpeed | read-only | mandatory | The nominal rotational speed (RPM) of the fans when they are operating at the 100% level. |
| 1.3.6.1.4.1.318.1.1.14.4.1.1.3 | ColumnrARUFanStatusSelectedFanLevel | read-only | mandatory | The currently selected ARU speed level, specified in percent of full capacity. |
| 1.3.6.1.4.1.318.1.1.14.4.1.1.4 | ColumnrARUFanStatusReplacementThreshold | read-write | mandatory | Threshold above which a run hour alarm will exist, indicating that it might be time to proactively replace a fan. |
| 1.3.6.1.4.1.318.1.1.14.4.1.1.5 | ColumnrARUFanStatusFanIndex | read-only | mandatory | The index to an individual fan table entry. |
| 1.3.6.1.4.1.318.1.1.14.4.1.1.6 | ColumnrARUFanStatusFanOperatingStatus | read-only | mandatory | The current operating state of the fan. |
| 1.3.6.1.4.1.318.1.1.14.4.1.1.7 | ColumnrARUFanStatusFanRpmSpeed | read-only | mandatory | The current rotational speed of the fan, specified in rotations per minute (RPM). |
| 1.3.6.1.4.1.318.1.1.14.4.1.1.8 | ColumnrARUFanStatusFanFlowRate | read-only | mandatory | The flow rate provided by the fan, based on its measured rotational speed. Specified in cfm (cubic feet per minute). Can be converted to metric values using th… |
| 1.3.6.1.4.1.318.1.1.14.4.1.1.9 | ColumnrARUFanStatusFanInServiceDate | read-write | mandatory | The installation/replacement date of the fan. |
| 1.3.6.1.4.1.318.1.1.14.4.1.1.10 | ColumnrARUFanStatusFanRunhourCounter | read-only | mandatory | The total time for which the fan has been running. Specified in 10ths of hours. |
| 1.3.6.1.4.1.318.1.1.14.4.1.1.11 | ColumnrARUFanStatusFanRunhourReset | read-write | mandatory | Writing yes to this This OID will reset a fan's total run hour counter, which is shown in the rARUFanStatusFanRunhourCounter OID. |
| 1.3.6.1.4.1.318.1.1.14.5 | NoderARUPower | |||
| 1.3.6.1.4.1.318.1.1.14.5.1 | TablerARUPowerStatusTable | not-accessible | mandatory | Allows for query of the individual ARUs accessible from this IP address. The number of entries is contained in the rARUStatusAruDeviceCount OID. |
| 1.3.6.1.4.1.318.1.1.14.5.1.1 | RowrARUPowerStatusEntry | not-accessible | mandatory | The device to query. |
| 1.3.6.1.4.1.318.1.1.14.5.1.1.1 | ColumnrARUPowerStatusAruIndex | read-only | mandatory | The index to the ARU entry. |
| 1.3.6.1.4.1.318.1.1.14.5.1.1.2 | ColumnrARUPowerStatusPrimaryAcPresent | read-only | mandatory | Indicates whether or not line voltage is present on AC input 1. |
| 1.3.6.1.4.1.318.1.1.14.5.1.1.3 | ColumnrARUPowerStatusAuxiliaryAcPresent | read-only | mandatory | Indicates whether or not line voltage is present on AC input 2. |
| 1.3.6.1.4.1.318.1.1.14.5.1.1.4 | ColumnrARUPowerStatusRedundantAcConfig | read-write | mandatory | Indicates whether or not a dual cord is in use. When this setting is set to dualCord (2), aruRedundantPowerLostAlarm traps will be generated when either primar… |
| 1.3.6.1.4.1.318.1.1.14.6 | NoderARUSensors | |||
| 1.3.6.1.4.1.318.1.1.14.6.1 | ScalarrARUSensorsStatusTableSize | read-only | mandatory | The number of entries in the rARUSensorsStatusTable. |
| 1.3.6.1.4.1.318.1.1.14.6.2 | TablerARUSensorsStatusTable | not-accessible | mandatory | Allows for getting environmental sensor status information. |
| 1.3.6.1.4.1.318.1.1.14.6.2.1 | RowrARUSensorsStatusEntry | not-accessible | mandatory | The unit to get data from. |
| 1.3.6.1.4.1.318.1.1.14.6.2.1.1 | ColumnrARUSensorsStatusAruIndex | read-only | mandatory | The index to the ARU entry. |
| 1.3.6.1.4.1.318.1.1.14.6.2.1.2 | ColumnrARUSensorsStatusSensorNumber | read-only | mandatory | The number of the sensor on the device. |
| 1.3.6.1.4.1.318.1.1.14.6.2.1.3 | ColumnrARUSensorsTemperature | read-only | mandatory | The sensor's current temperature reading. The temperature scale is based on the system preferences configuration. |
| 1.3.6.1.4.1.318.1.1.14.6.3 | ScalarrARUSensorsConfigTableSize | read-only | mandatory | The number of entries in the rARUSensorsConfigTable. |
| 1.3.6.1.4.1.318.1.1.14.6.4 | TablerARUSensorsConfigTable | not-accessible | mandatory | Allows for getting configuration information from environmental sensors attached to the device. |
| 1.3.6.1.4.1.318.1.1.14.6.4.1 | RowrARUSensorsConfigEntry | not-accessible | mandatory | The unit to get data from. |
| 1.3.6.1.4.1.318.1.1.14.6.4.1.1 | ColumnrARUSensorsConfigAruIndex | read-only | mandatory | The index to the ARU entry. |
| 1.3.6.1.4.1.318.1.1.14.6.4.1.2 | ColumnrARUSensorsConfigSensorNumber | read-only | mandatory | The number of the sensor on the device. |
| 1.3.6.1.4.1.318.1.1.14.6.4.1.3 | ColumnrARUSensorsName | read-write | mandatory | A descriptive name for the sensor. |
| 1.3.6.1.4.1.318.1.1.14.6.4.1.4 | ColumnrARUSensorsLocation | read-write | mandatory | The location of the sensor. |
| 1.3.6.1.4.1.318.1.1.14.6.4.1.5 | ColumnrARUSensorsTempMaxThresh | read-write | mandatory | The temperature at which a maximum temperature threshold violation alarm will be generated for this sensor. The temperature scale is based on the system prefer… |
| 1.3.6.1.4.1.318.1.1.14.6.4.1.6 | ColumnrARUSensorsTempHighThresh | read-write | mandatory | The temperature at which a high temperature threshold violation alarm will be generated for this sensor. The temperature scale is based on the system preferenc… |
| 1.3.6.1.4.1.318.1.1.14.6.4.1.7 | ColumnrARUSensorsTempLowThresh | read-write | mandatory | The temperature at which a low temperature threshold violation alarm will be generated for this sensor. The temperature scale is based on the system preference… |
| 1.3.6.1.4.1.318.1.1.14.6.4.1.8 | ColumnrARUSensorsTempMinThresh | read-write | mandatory | The temperature at which a min temperature threshold violation alarm will be generated for this sensor. The temperature scale is based on the system preference… |
| 1.3.6.1.4.1.318.1.1.14.6.4.1.9 | ColumnrARUSensorsTempThreshHysteresis | read-write | mandatory | The change in temperature required to cause a temperature alarm to change from an active to an inactive state. The temperature scale is based on the system pre… |
| 1.3.6.1.4.1.318.1.1.14.6.4.1.10 | ColumnrARUSensorsTempShortDecRateThreshValue | read-write | mandatory | The value of the temperature short-term decreasing rate time that will cause an alarm to be generated. The temperature scale is based on the system preferences… |
| 1.3.6.1.4.1.318.1.1.14.6.4.1.11 | ColumnrARUSensorsTempShortDecRateThreshTime | read-write | mandatory | The time over which the temperature may not decrease beyond the value specified by the temperature short-term decreasing rate threshold value. |
| 1.3.6.1.4.1.318.1.1.14.6.4.1.12 | ColumnrARUSensorsTempShortIncRateThreshValue | read-write | mandatory | The value of the temperature short-term increasing rate time that will cause an alarm to be generated. The temperature scale is based on the system preferences… |
| 1.3.6.1.4.1.318.1.1.14.6.4.1.13 | ColumnrARUSensorsTempShortIncRateThreshTime | read-write | mandatory | The time over which the temperature may not increase beyond the value specified by the temperature short-term increasing rate threshold value. |
| 1.3.6.1.4.1.318.1.1.14.6.4.1.14 | ColumnrARUSensorsTempLongDecRateThreshValue | read-write | mandatory | The value of the temperature long-term decreasing rate time that will cause an alarm to be generated. The temperature scale is based on the system preferences … |
| 1.3.6.1.4.1.318.1.1.14.6.4.1.15 | ColumnrARUSensorsTempLongDecRateThreshTime | read-write | mandatory | The time over which the temperature may not decrease beyond the value specified by the temperature long-term decreasing rate threshold value. |
| 1.3.6.1.4.1.318.1.1.14.6.4.1.16 | ColumnrARUSensorsTempLongIncRateThreshValue | read-write | mandatory | The value of the temperature long-term increasing rate time that will cause an alarm to be generated. The temperature scale is based on the system preferences … |
| 1.3.6.1.4.1.318.1.1.14.6.4.1.17 | ColumnrARUSensorsTempLongIncRateThreshTime | read-write | mandatory | The time over which the temperature may not increase beyond the value specified by the temperature long-term increasing rate threshold value. |
| 1.3.6.1.4.1.318.1.1.15 | NodexPDU | |||
| 1.3.6.1.4.1.318.1.1.15.1 | NodexPDUIdent | |||
| 1.3.6.1.4.1.318.1.1.15.1.1 | ScalarxPDUIdentProductName | read-write | mandatory | The name of the PDU. |
| 1.3.6.1.4.1.318.1.1.15.1.2 | ScalarxPDUIdentHardwareRev | read-only | mandatory | The hardware revision of the PDU. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.15.1.3 | ScalarxPDUIdentFirmwareAppRev | read-only | mandatory | An ID string identifying the application firmware revision of the PDU. |
| 1.3.6.1.4.1.318.1.1.15.1.4 | ScalarxPDUIdentFirmwareAppOSRev | read-only | mandatory | An ID string identifying the application operating system firmware revision of the PDU. |
| 1.3.6.1.4.1.318.1.1.15.1.5 | ScalarxPDUIdentFirmwareControllerRev | read-only | mandatory | An ID string identifying the PDU controller firmware revision. |
| 1.3.6.1.4.1.318.1.1.15.1.6 | ScalarxPDUIdentDateOfManufacture | read-only | mandatory | The date when the PDU was manufactured in mm/dd/yyyy format. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.15.1.7 | ScalarxPDUIdentModelNumber | read-only | mandatory | A character string identifying the model number of the PDU. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.15.1.8 | ScalarxPDUIdentSerialNumber | read-only | mandatory | A character string identifying the serial number of the PDU. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.15.2 | NodexPDUDevice | |||
| 1.3.6.1.4.1.318.1.1.15.2.1 | ScalarxPDUDeviceNominalMainInputVoltage | read-only | mandatory | The nominal main input voltage to the PDU. Measured in Volts, line-to-line for a 3-wire (delta) service or line-to-neutral for a 4-wire (wye) service. |
| 1.3.6.1.4.1.318.1.1.15.2.2 | ScalarxPDUDeviceServiceType | read-only | mandatory | The type of utility input to the PDU. Either 3 wires (delta), or 4 wires (wye). |
| 1.3.6.1.4.1.318.1.1.15.2.3 | ScalarxPDUDeviceNominalOutputVoltage | read-only | mandatory | The nominal line-to-neutral output voltage to the load measured in Volts. |
| 1.3.6.1.4.1.318.1.1.15.2.4 | ScalarxPDUDeviceMainInputBreakerRating | read-only | mandatory | The rating of the main input breaker measured in Amps. |
| 1.3.6.1.4.1.318.1.1.15.2.5 | ScalarxPDUDevicePanelBreakerRating | read-only | mandatory | The rating of the panel breaker measured in Amps. |
| 1.3.6.1.4.1.318.1.1.15.2.6 | ScalarxPDUDeviceTransformerPresent | read-only | mandatory | Indicates whether or not a transformer is installed in the PDU. |
| 1.3.6.1.4.1.318.1.1.15.2.7 | ScalarxPDUDeviceLoadTieBreakerPresent | read-only | mandatory | Indicates whether or not a load tie breaker is installed in the PDU. |
| 1.3.6.1.4.1.318.1.1.15.2.8 | ScalarxPDUDeviceLoadTestPortPresent | read-only | mandatory | Indicates whether or not a load test port is installed in the PDU. |
| 1.3.6.1.4.1.318.1.1.15.2.9 | ScalarxPDUDeviceFusesPresent | read-only | mandatory | Indicates whether or not the UPS feed from the PDU includes fuses. |
| 1.3.6.1.4.1.318.1.1.15.2.10 | ScalarxPDUDeviceFansPresent | read-only | mandatory | Indicates whether or not cooling fans are installed in the PDU. |
| 1.3.6.1.4.1.318.1.1.15.2.11 | ScalarxPDUDeviceBypassInputPresent | read-only | mandatory | Indicates whether or not the PDU is equipped with a second feed for the UPS's bypass input. |
| 1.3.6.1.4.1.318.1.1.15.2.12 | ScalarxPDUDeviceCrossTieOutputPresent | read-only | mandatory | Indicates whether or not the PDU is equipped with a cross-tie output. |
| 1.3.6.1.4.1.318.1.1.15.2.13 | ScalarxPDUDeviceEarthGroundMonitorPresent | read-only | mandatory | Indicates whether or not the PDU can provide ground current measurements. |
| 1.3.6.1.4.1.318.1.1.15.2.14 | ScalarxPDUDeviceInfraStruXureType | read-only | mandatory | Indicates the configuration of this PDU system. Type-B PDU is in a distributed UPS system and has bypass capabilities. Type-C PDU receives power from a larger … |
| 1.3.6.1.4.1.318.1.1.15.3 | NodexPDUACMonitoringPoint | |||
| 1.3.6.1.4.1.318.1.1.15.3.1 | NodexPDUMainInput | |||
| 1.3.6.1.4.1.318.1.1.15.3.1.1 | ScalarxPDUMainInputOverVoltThreshold | read-write | mandatory | Threshold above which an input over voltage condition will be generated. Specified as percent deviation from nominal. |
| 1.3.6.1.4.1.318.1.1.15.3.1.2 | ScalarxPDUMainInputUnderVoltThreshold | read-write | mandatory | Threshold below which an input under voltage condition will be generated. Specified as percent deviation from nominal. A value of zero indicates that the thres… |
| 1.3.6.1.4.1.318.1.1.15.3.1.3 | ScalarxPDUMainInputVoltageTableSize | read-only | mandatory | The number of Main input voltage entries. |
| 1.3.6.1.4.1.318.1.1.15.3.1.4 | TablexPDUMainInputVoltagePhaseTable | not-accessible | mandatory | A list of input voltage table entries. The number of entries are the phase entries. The number of entries is contained in the xPDUMainInputVoltageTableSize OID. |
| 1.3.6.1.4.1.318.1.1.15.3.1.4.1 | RowxPDUMainInputVoltagePhaseEntry | not-accessible | mandatory | An entry containing information applicable to a particular main input voltage phase. |
| 1.3.6.1.4.1.318.1.1.15.3.1.4.1.1 | ColumnxPDUMainInputVoltagePhaseIndex | read-only | mandatory | Description of each input phase entry in the table. |
| 1.3.6.1.4.1.318.1.1.15.3.1.4.1.2 | ColumnxPDUMainInputVoltageLtoL | read-only | mandatory | Line-to-line PDU input voltage when an isolation transformer is present, or -1 if no transformer present in this PDU. Measured in tenths of Volts. |
| 1.3.6.1.4.1.318.1.1.15.3.1.4.1.3 | ColumnxPDUMainInputVoltageLtoN | read-only | mandatory | Line-to-neutral PDU input voltage when an isolation transformer is not present, or -1 if a transformer is present in this PDU. Measured in tenths of Volts. |
| 1.3.6.1.4.1.318.1.1.15.3.2 | NodexPDUBypassInput | |||
| 1.3.6.1.4.1.318.1.1.15.3.2.1 | ScalarxPDUBypassInputOverVoltThreshold | read-write | mandatory | Threshold above which a bypass input over voltage condition will be generated. Specified as percent deviation from nominal. |
| 1.3.6.1.4.1.318.1.1.15.3.2.2 | ScalarxPDUBypassInputUnderVoltThreshold | read-write | mandatory | Threshold below which an bypass input under voltage condition will be generated. Specified as percent deviation from nominal. A value of zero indicates that th… |
| 1.3.6.1.4.1.318.1.1.15.3.2.3 | ScalarxPDUBypassInputVoltagePhaseTableSize | read-only | mandatory | The number of bypass input voltage entries. |
| 1.3.6.1.4.1.318.1.1.15.3.2.4 | TablexPDUBypassInputVoltagePhaseTable | not-accessible | mandatory | A list of output table entries. The number of entries are the phase entries. The number of entries is contained in the xPDUBypassInputVoltagePhaseTableSize OID. |
| 1.3.6.1.4.1.318.1.1.15.3.2.4.1 | RowxPDUBypassInputVoltagePhaseEntry | not-accessible | mandatory | An entry containing information applicable to a particular bypass input voltage phase. |
| 1.3.6.1.4.1.318.1.1.15.3.2.4.1.1 | ColumnxPDUBypassInputVoltagePhaseIndex | read-only | mandatory | Index of each bypass input phase entry in the table. |
| 1.3.6.1.4.1.318.1.1.15.3.2.4.1.2 | ColumnxPDUBypassInputVoltageLtoL | read-only | mandatory | Line-to-line bypass input voltage, or -1 if no bypass feed is present in this PDU. Measured in tenths of Volts. |
| 1.3.6.1.4.1.318.1.1.15.3.2.4.1.3 | ColumnxPDUBypassInputVoltageLtoN | read-only | mandatory | Line-to-neutral bypass input voltage, or -1 if no bypass feed is present in this PDU. Measured in tenths of Volts. |
| 1.3.6.1.4.1.318.1.1.15.3.3 | NodexPDUUPSInput | |||
| 1.3.6.1.4.1.318.1.1.15.3.3.1 | ScalarxPDUUPSInputVoltagePhaseTableSize | read-only | mandatory | The number of UPS input voltage entries. |
| 1.3.6.1.4.1.318.1.1.15.3.3.2 | TablexPDUUPSInputVoltagePhaseTable | not-accessible | mandatory | A list of UPS input table entries. The number of entries are the phase entries. The number of entries is contained in the xPDUUPSInputVoltagePhaseTableSize OID. |
| 1.3.6.1.4.1.318.1.1.15.3.3.2.1 | RowxPDUUPSInputVoltagePhaseEntry | not-accessible | mandatory | An entry containing information applicable to a particular UPS input voltage phase. |
| 1.3.6.1.4.1.318.1.1.15.3.3.2.1.1 | ColumnxPDUUPSInputVoltagePhaseIndex | read-only | mandatory | Description of each UPS input phase entry in the table. |
| 1.3.6.1.4.1.318.1.1.15.3.3.2.1.2 | ColumnxPDUUPSInputVoltageLtoNPresent | read-only | mandatory | Indicates whether or not voltage is present at the UPS feed. |
| 1.3.6.1.4.1.318.1.1.15.3.4 | NodexPDUSystemOutput | |||
| 1.3.6.1.4.1.318.1.1.15.3.4.1 | ScalarxPDUSystemOutputFrequency | read-only | mandatory | The system output frequency in tenths of Hertz. |
| 1.3.6.1.4.1.318.1.1.15.3.4.2 | ScalarxPDUSystemOutputNeutralCurrent | read-only | mandatory | Shows the neutral current measured at the system output in tenths of Amps. |
| 1.3.6.1.4.1.318.1.1.15.3.4.3 | ScalarxPDUSystemOutputTotalPower | read-only | mandatory | Shows the total system output power in tenths of kW. |
| 1.3.6.1.4.1.318.1.1.15.3.4.4 | ScalarxPDUSystemOutputTotalApparentPower | read-only | mandatory | Shows the total system output power in tenths of kVA. |
| 1.3.6.1.4.1.318.1.1.15.3.4.5 | ScalarxPDUSystemOutputTotalPowerFactor | read-only | mandatory | Indicates the total power factor of the system output. A value of 100 representing a unity power factor (1.00). Measured in hundredths. |
| 1.3.6.1.4.1.318.1.1.15.3.4.6 | ScalarxPDUSystemOutputFrequencyTolerance | read-write | mandatory | Shows the circuit panel output frequency tolerance in Hertz. |
| 1.3.6.1.4.1.318.1.1.15.3.4.7 | ScalarxPDUSystemOutputMaxKWPower | read-write | mandatory | Defines 100% load in kW. Purpose is to set to match UPS capabilities. |
| 1.3.6.1.4.1.318.1.1.15.3.4.8 | ScalarxPDUSystemOutputOverVoltThreshold | read-write | mandatory | Threshold above which an output over voltage condition will be generated. Specified as percent deviation from nominal. |
| 1.3.6.1.4.1.318.1.1.15.3.4.9 | ScalarxPDUSystemOutputUnderVoltThreshold | read-write | mandatory | Threshold below which an output under voltage condition will be generated. Specified as percent deviation from nominal. A value of zero indicates that the thre… |
| 1.3.6.1.4.1.318.1.1.15.3.4.10 | ScalarxPDUSystemOutputOverCurrentThreshold | read-write | mandatory | Threshold above which an over current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the thres… |
| 1.3.6.1.4.1.318.1.1.15.3.4.11 | ScalarxPDUSystemOutputOverCurrentNeutralThreshold | read-write | mandatory | Threshold above which an Over current neutral condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that t… |
| 1.3.6.1.4.1.318.1.1.15.3.4.12 | ScalarxPDUSystemOutputUnderCurrentThreshold | read-write | mandatory | Threshold below which an under current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the thre… |
| 1.3.6.1.4.1.318.1.1.15.3.4.13 | ScalarxPDUSystemOutputTableSize | read-only | mandatory | The number of System Output phase entries. |
| 1.3.6.1.4.1.318.1.1.15.3.4.14 | TablexPDUSystemOutputPhaseTable | not-accessible | mandatory | A list of system output table entries. The number of entries is contained in the xPDUSystemOutputTableSize OID. |
| 1.3.6.1.4.1.318.1.1.15.3.4.14.1 | RowxPDUSystemOutputPhaseEntry | not-accessible | mandatory | An entry containing information applicable to a particular system output phase. |
| 1.3.6.1.4.1.318.1.1.15.3.4.14.1.1 | ColumnxPDUSystemOutputPhaseIndex | read-only | mandatory | Description of each output phase entry in the table. |
| 1.3.6.1.4.1.318.1.1.15.3.4.14.1.2 | ColumnxPDUSystemOutputVoltageLtoL | read-only | mandatory | Line-to-line system output voltage available at the circuit panel. Measured in tenths of Volts. |
| 1.3.6.1.4.1.318.1.1.15.3.4.14.1.3 | ColumnxPDUSystemOutputVoltageLtoN | read-only | mandatory | Line-to-neutral system output voltage available at the circuit panel. Measured in tenths of Volts. |
| 1.3.6.1.4.1.318.1.1.15.3.4.14.1.4 | ColumnxPDUSystemOutputPhaseCurrent | read-only | mandatory | System load current per phase. Measured in tenths of Amps. |
| 1.3.6.1.4.1.318.1.1.15.3.4.14.1.5 | ColumnxPDUSystemOutputPower | read-only | mandatory | System output power per phase. Measured in tenths of kW. |
| 1.3.6.1.4.1.318.1.1.15.3.4.14.1.6 | ColumnxPDUSystemOutputApparentPower | read-only | mandatory | System output power per phase. Measured in tenths of kVA. |
| 1.3.6.1.4.1.318.1.1.15.3.4.14.1.7 | ColumnxPDUSystemOutputPowerFactor | read-only | mandatory | Indicates the Power Factor of the system output per phase. A value of 100 representing a unity Power Factor (1.00). Measured in hundredths. |
| 1.3.6.1.4.1.318.1.1.15.3.5 | NodexPDUGroundMonitorPoint | |||
| 1.3.6.1.4.1.318.1.1.15.3.5.1 | ScalarxPDUGroundCurrent | read-only | mandatory | Shows the current measured in the earth ground conductor. Measured in tenths of Amps, or -1 if not available. |
| 1.3.6.1.4.1.318.1.1.15.3.5.2 | ScalarxPDUGroundCurrentThreshold | read-write | mandatory | Threshold above which a ground current over current condition will be generated. Specified in tenths of Amps. |
| 1.3.6.1.4.1.318.1.1.15.4 | NodexPDUCircuitBreakers | |||
| 1.3.6.1.4.1.318.1.1.15.4.1 | NodexPDUSystemBreakers | |||
| 1.3.6.1.4.1.318.1.1.15.4.1.1 | ScalarxPDUSystemBreakerTableSize | read-only | mandatory | The number of system breaker entries. |
| 1.3.6.1.4.1.318.1.1.15.4.1.2 | TablexPDUSystemBreakerTable | not-accessible | mandatory | A list of system breaker entries. The number of entries is contained in the xPDUSystemBreakerTableSize OID. |
| 1.3.6.1.4.1.318.1.1.15.4.1.2.1 | RowxPDUSystemBreakerEntry | not-accessible | mandatory | An entry containing information applicable to a particular system breaker. |
| 1.3.6.1.4.1.318.1.1.15.4.1.2.1.1 | ColumnxPDUSystemBreakerTableIndex | read-only | mandatory | Index of system breaker entries in the table. |
| 1.3.6.1.4.1.318.1.1.15.4.1.2.1.2 | ColumnxPDUSystemBreakerDescription | read-only | mandatory | A brief description of the system breakers. |
| 1.3.6.1.4.1.318.1.1.15.4.1.2.1.3 | ColumnxPDUSystemBreakerPosition | read-only | mandatory | Indicates whether this breaker is open(1) or closed(2). |
| 1.3.6.1.4.1.318.1.1.15.4.2 | NodexPDUBranchBreakers | |||
| 1.3.6.1.4.1.318.1.1.15.4.2.1 | ScalarxPDUNumOfBranchBreakers | read-only | mandatory | The number of branch breakers (panel positions) in the Panel. returns 42 for a 1-panel or 84 for a 2-panel system. |
| 1.3.6.1.4.1.318.1.1.15.4.2.2 | ScalarxPDUBranchBreakerTableSize | read-only | mandatory | The number of branch breaker entries determined by the xPDUNumOfBranchBreakers OID. |
| 1.3.6.1.4.1.318.1.1.15.4.2.3 | TablexPDUBranchBreakerTable | not-accessible | mandatory | A list of branch breaker table entries. The number of entries is given by the value of xPDUBranchBreakerTableSize The number of entries is contained in the xPD… |
| 1.3.6.1.4.1.318.1.1.15.4.2.3.1 | RowxPDUBranchBreakerEntry | not-accessible | mandatory | An entry containing information applicable to a particular branch breaker (panel position). |
| 1.3.6.1.4.1.318.1.1.15.4.2.3.1.1 | ColumnxPDUBranchBreakerTableIndex | read-only | mandatory | Index of branch breaker entries in the table. |
| 1.3.6.1.4.1.318.1.1.15.4.2.3.1.2 | ColumnxPDUBranchBreakerRating | read-write | mandatory | Indicates current rating of this breaker. 0=Breaker is not present. 1=Earth leakage connection. 2=Neutral connection. A value greater than 2 indicates breaker … |
| 1.3.6.1.4.1.318.1.1.15.4.2.3.1.3 | ColumnxPDUBranchBreakerRDPFeed | read-only | mandatory | Indicates that a breaker position is feeding a remote distribution panel. |
| 1.3.6.1.4.1.318.1.1.15.4.2.3.1.4 | ColumnxPDUBranchBreakerTieIndicator | read-write | mandatory | Indicates whether or not the breaker in this position is logically associated with the breaker immediately below it. This setting is used grouping the breakers… |
| 1.3.6.1.4.1.318.1.1.15.4.2.3.1.5 | ColumnxPDUBranchBreakerCurrent | read-only | mandatory | Indicates the branch current in tenths of Amps or -1 when not available. |
| 1.3.6.1.4.1.318.1.1.15.4.2.3.1.6 | ColumnxPDUBranchBreakerOverCurrentThreshold | read-write | mandatory | Threshold above which a branch circuit high current condition will be generated. Specified as a percent of the branch breaker rating. A value of zero indicates… |
| 1.3.6.1.4.1.318.1.1.15.4.2.3.1.7 | ColumnxPDUBranchBreakerUnderCurrentThreshold | read-write | mandatory | Threshold below which a branch circuit low current condition will be generated. Specified as a percent of the branch breaker rating. A value of zero indicates … |
| 1.3.6.1.4.1.318.1.1.15.4.2.3.1.8 | ColumnxPDUBranchBreakerMaxCurrentThreshold | read-write | mandatory | Threshold above which a branch circuit maximum current condition will be generated. Specified as a percent of the branch breaker rating. A value of zero indica… |
| 1.3.6.1.4.1.318.1.1.15.4.2.3.1.9 | ColumnxPDUBranchBreakerMinCurrentThreshold | read-write | mandatory | Threshold below which a branch circuit minimum current condition will be generated. Specified as a percent of the branch breaker rating. A value of zero indica… |
| 1.3.6.1.4.1.318.1.1.15.4.2.3.1.10 | ColumnxPDUBranchBreakerName | read-write | mandatory | The description of the purpose/use of the breaker. |
| 1.3.6.1.4.1.318.1.1.15.4.2.3.1.11 | ColumnxPDUBranchBreakerLocation | read-write | mandatory | The description of the location of the breaker. |
| 1.3.6.1.4.1.318.1.1.15.5 | NodexPDUInputContacts | |||
| 1.3.6.1.4.1.318.1.1.15.5.1 | ScalarxPDUInputContactNumContacts | read-only | mandatory | The number of contacts supported by the PDU. |
| 1.3.6.1.4.1.318.1.1.15.5.2 | ScalarxPDUInputContactTableSize | read-only | mandatory | The number of input contact entries. |
| 1.3.6.1.4.1.318.1.1.15.5.3 | TablexPDUInputContactTable | not-accessible | mandatory | A list of contacts supported by the PDU. The number of entries is contained in the xPDUInputContactTableSize OID. |
| 1.3.6.1.4.1.318.1.1.15.5.3.1 | RowxPDUInputContactEntry | not-accessible | mandatory | A contact entry containing information for a given contact. |
| 1.3.6.1.4.1.318.1.1.15.5.3.1.1 | ColumnxPDUInputContactNumber | read-only | mandatory | An index identifying the contact on the PDU. |
| 1.3.6.1.4.1.318.1.1.15.5.3.1.2 | ColumnxPDUInputContactName | read-write | mandatory | The description of the purpose/use of the contact. |
| 1.3.6.1.4.1.318.1.1.15.5.3.1.3 | ColumnxPDUInputContactNormalState | read-write | mandatory | The normal operating position of the contact. |
| 1.3.6.1.4.1.318.1.1.15.5.3.1.4 | ColumnxPDUInputContactCurrentState | read-only | mandatory | This value indicates the current state of the contact. |
| 1.3.6.1.4.1.318.1.1.15.6 | NodexPDUOutputRelays | |||
| 1.3.6.1.4.1.318.1.1.15.6.1 | ScalarxPDUOutputRelaysNumRelays | read-only | mandatory | The number of output relays supported by the PDU. |
| 1.3.6.1.4.1.318.1.1.15.6.2 | ScalarxPDUOutputRelaysTableSize | read-only | mandatory | The number of output relay entries. |
| 1.3.6.1.4.1.318.1.1.15.6.3 | TablexPDUOutputRelayTable | not-accessible | mandatory | A list of output relays supported by the PDU. The number of entries is contained in the xPDUOutputRelayTableSize OID. |
| 1.3.6.1.4.1.318.1.1.15.6.3.1 | RowxPDUOutputRelayEntry | not-accessible | mandatory | A output relay entry containing information for a given contact. |
| 1.3.6.1.4.1.318.1.1.15.6.3.1.1 | ColumnxPDUOutputRelayNumber | read-only | mandatory | An index identifying the output relay on the PDU. |
| 1.3.6.1.4.1.318.1.1.15.6.3.1.2 | ColumnxPDUOutputRelayName | read-write | mandatory | The description of the purpose/use of the output relay. |
| 1.3.6.1.4.1.318.1.1.15.6.3.1.3 | ColumnxPDUOutputRelayNormalState | read-write | mandatory | The normal operating position of the output relay. |
| 1.3.6.1.4.1.318.1.1.15.6.3.1.4 | ColumnxPDUOutputRelayCurrentState | read-only | mandatory | This value indicates the current state of the output relay. |
| 1.3.6.1.4.1.318.1.1.15.7 | NodexPDUMiscGroup | |||
| 1.3.6.1.4.1.318.1.1.15.7.1 | ScalarxPDUEPOMode | read-only | mandatory | Indicates whether the EPO System is armed(1) or disarmed(2). |
| 1.3.6.1.4.1.318.1.1.15.7.2 | ScalarxPDUTransformTempStatus | read-only | mandatory | Indicates if the PDU's isolation transformer is over temperature. |
| 1.3.6.1.4.1.318.1.1.15.7.3 | ScalarxPDUCoolingFanStatus | read-only | mandatory | Indicates if one or more of the PDU's cooling fans have failed. |
| 1.3.6.1.4.1.318.1.1.16 | NodebattMan | |||
| 1.3.6.1.4.1.318.1.1.16.1 | NodebattManIdent | |||
| 1.3.6.1.4.1.318.1.1.16.1.1 | ScalarbattManIdentProductName | read-write | mandatory | The name of the battery manager. |
| 1.3.6.1.4.1.318.1.1.16.1.2 | ScalarbattManIdentHardwareRev | read-only | mandatory | The battery manager network interface hardware revision. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.16.1.3 | ScalarbattManIdentFirmwareRev | read-only | mandatory | The battery manager network interface firmware revision. This value is set at the factory and can change with firmware update. |
| 1.3.6.1.4.1.318.1.1.16.1.4 | ScalarbattManIdentDateOfManufacture | read-only | mandatory | The date the battery manager was manufactured in mm/dd/yyyy format. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.16.1.5 | ScalarbattManIdentModelNumber | read-only | mandatory | The battery manager model number character string. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.16.1.6 | ScalarbattManIdentSerialNumber | read-only | mandatory | The battery manager serial number character string. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.16.2 | NodebattManSystemCalib | |||
| 1.3.6.1.4.1.318.1.1.16.2.1 | ScalarbattManOhmicValueCorrectionFactor | read-write | mandatory | The system ohmic value correction factor in percent. |
| 1.3.6.1.4.1.318.1.1.16.3 | NodebattManUnitCalib | |||
| 1.3.6.1.4.1.318.1.1.16.3.1 | ScalarbattManUnitCalibTableSize | read-only | mandatory | The number of entries in the battManUnitCalibTable. |
| 1.3.6.1.4.1.318.1.1.16.3.2 | TablebattManUnitCalibTable | not-accessible | mandatory | Allows for getting calibration information from each unit in the system. |
| 1.3.6.1.4.1.318.1.1.16.3.2.1 | RowbattManUnitCalibEntry | not-accessible | mandatory | The unit to get data from. |
| 1.3.6.1.4.1.318.1.1.16.3.2.1.1 | ColumnbattManUnitCalibIndex | read-only | mandatory | Index of unit calibration entries in the table. |
| 1.3.6.1.4.1.318.1.1.16.3.2.1.2 | ColumnbattManUnitSerialNumber | read-only | mandatory | The serial number of the unit. |
| 1.3.6.1.4.1.318.1.1.16.3.2.1.3 | ColumnbattManBatteryVoltageZeroCalib | read-write | mandatory | The unit battery voltage zero calibration in millivolts. |
| 1.3.6.1.4.1.318.1.1.16.3.2.1.4 | ColumnbattManBatteryVoltageSpanCalib | read-write | mandatory | The unit battery voltage span calibration in hundredths of percent. |
| 1.3.6.1.4.1.318.1.1.16.4 | NodebattManStringCalib | |||
| 1.3.6.1.4.1.318.1.1.16.4.1 | ScalarbattManStringCalibTableSize | read-only | mandatory | The number of entries in the battManStringCalibTable. |
| 1.3.6.1.4.1.318.1.1.16.4.2 | TablebattManStringCalibTable | not-accessible | mandatory | Allows for getting calibration information from each string in the system. |
| 1.3.6.1.4.1.318.1.1.16.4.2.1 | RowbattManStringCalibEntry | not-accessible | mandatory | The string to get data from. |
| 1.3.6.1.4.1.318.1.1.16.4.2.1.1 | ColumnbattManStringCalibIndex | read-only | mandatory | Index of string calibration entries in the table. |
| 1.3.6.1.4.1.318.1.1.16.4.2.1.2 | ColumnbattManDCCurrentZeroCalib | read-write | mandatory | The string DC current zero calibration in tenths of amps. |
| 1.3.6.1.4.1.318.1.1.16.4.2.1.3 | ColumnbattManACCurrentZeroCalib | read-write | mandatory | The string AC current zero calibration in tenths of amps. |
| 1.3.6.1.4.1.318.1.1.16.4.2.1.4 | ColumnbattManProbeRange | read-write | mandatory | The string probe range in amps. |
| 1.3.6.1.4.1.318.1.1.16.5 | NodebattManBatteryCalib | |||
| 1.3.6.1.4.1.318.1.1.16.5.1 | ScalarbattManString1BatteryCalibTableSize | read-only | mandatory | The number of entries in the battManString1BatteryCalibTable. |
| 1.3.6.1.4.1.318.1.1.16.5.2 | TablebattManString1BatteryCalibTable | not-accessible | mandatory | Allows for getting calibration information from each battery in String 1. |
| 1.3.6.1.4.1.318.1.1.16.5.2.1 | RowbattManString1BatteryCalibEntry | not-accessible | mandatory | The string to get data from. |
| 1.3.6.1.4.1.318.1.1.16.5.2.1.1 | ColumnbattManString1BatteryCalibIndex | read-only | mandatory | Index of battery calibration entries in the table. |
| 1.3.6.1.4.1.318.1.1.16.5.2.1.2 | ColumnbattManString1BatteryInterTierOhmicValue | read-write | mandatory | The battery inter-tier ohmic value in ohms. This corresponds to the ohmic value for the positive terminal of the battery. |
| 1.3.6.1.4.1.318.1.1.16.5.3 | ScalarbattManString2BatteryCalibTableSize | read-only | mandatory | The number of entries in the battManString2BatteryCalibTable. |
| 1.3.6.1.4.1.318.1.1.16.5.4 | TablebattManString2BatteryCalibTable | not-accessible | mandatory | Allows for getting calibration information from each battery in String 2. |
| 1.3.6.1.4.1.318.1.1.16.5.4.1 | RowbattManString2BatteryCalibEntry | not-accessible | mandatory | The string to get data from. |
| 1.3.6.1.4.1.318.1.1.16.5.4.1.1 | ColumnbattManString2BatteryCalibIndex | read-only | mandatory | Index of battery calibration entries in the table. |
| 1.3.6.1.4.1.318.1.1.16.5.4.1.2 | ColumnbattManString2BatteryInterTierOhmicValue | read-write | mandatory | The battery inter-tier ohmic value in ohms. |
| 1.3.6.1.4.1.318.1.1.16.6 | NodebattManConfig | |||
| 1.3.6.1.4.1.318.1.1.16.6.1 | ScalarbattManConfigApplication | read-write | deprecated | This OID has been deprecated. |
| 1.3.6.1.4.1.318.1.1.16.6.2 | ScalarbattManConfigBatteryChemistry | read-write | mandatory | The battery chemistry of the monitored batteries: LeadAcid(1) Lead Acid or Nickel-Cadmium(2) Nickel-Cadmium. |
| 1.3.6.1.4.1.318.1.1.16.6.3 | ScalarbattManConfigBatteryAHCapacity | read-write | mandatory | The amp hour capacity of the monitored batteries 5-4000 AH. |
| 1.3.6.1.4.1.318.1.1.16.6.4 | ScalarbattManConfigNumberofStrings | read-write | mandatory | The number of strings in the battery manager system. |
| 1.3.6.1.4.1.318.1.1.16.6.5 | ScalarbattManConfigBatteriesperString | read-write | mandatory | The number of batteries per string. |
| 1.3.6.1.4.1.318.1.1.16.6.6 | ScalarbattManConfigCellsperBattery | read-write | mandatory | The number of cells per battery (1, 2, 4 or 6 for lead-acid, 1 or 2 for NiCd. |
| 1.3.6.1.4.1.318.1.1.16.6.7 | ScalarbattManConfigMinCellVoltage | read-write | mandatory | The minimum battery cell voltage alarm limit in millivolts DC. |
| 1.3.6.1.4.1.318.1.1.16.6.8 | ScalarbattManConfigMaxCellVoltage | read-write | mandatory | The maximum battery cell voltage alarm limit in millivolts DC. |
| 1.3.6.1.4.1.318.1.1.16.6.9 | ScalarbattManConfigMaxPilotTempF | read-write | mandatory | The maximum pilot battery temperature alarm limit in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.16.6.10 | ScalarbattManConfigMaxPilotTempC | read-write | mandatory | The maximum pilot battery temperature alarm limit in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.16.6.11 | ScalarbattManConfigMaxAmbientTempF | read-write | mandatory | The maximum ambient temperature alarm limit in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.16.6.12 | ScalarbattManConfigMaxAmbientTempC | read-write | mandatory | The maximum ambient temperature alarm limit in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.16.6.13 | ScalarbattManConfigMinAmbientTempF | read-write | mandatory | The Minimum Ambient Temperature alarm limit in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.16.6.14 | ScalarbattManConfigMinAmbientTempC | read-write | mandatory | The Minimum Ambient Temperature alarm limit in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.16.6.15 | ScalarbattManConfigMaxRippleCurrent | read-write | mandatory | The maximum ripple current alarm limit for the monitored battery strings in percent of AH capacity. |
| 1.3.6.1.4.1.318.1.1.16.6.16 | ScalarbattManConfigMaxCurrentAcceptanceDeviation | read-write | mandatory | The maximum current acceptance deviation alarm limit in percent. |
| 1.3.6.1.4.1.318.1.1.16.6.17 | ScalarbattManConfigMonitorWireLength | read-write | mandatory | The monitor wire length: fiftyFeetOrLess (1) indicates that the wire length is less than or equal to 50 feet. moreThanFiftyFeet (2) indicates that the wire len… |
| 1.3.6.1.4.1.318.1.1.16.6.18 | ScalarbattManConfigDischargeVoltageAlarmLevel | read-write | mandatory | The discharge voltage alarm level in percent. |
| 1.3.6.1.4.1.318.1.1.16.6.19 | ScalarbattManConfigAutoAnnunciatorReset | read-write | mandatory | The annunciator output signal reset method: disabled(1) means the annunciator signal output will be reset when the reset button is pressed. enabled(2) means th… |
| 1.3.6.1.4.1.318.1.1.16.6.20 | ScalarbattManConfigSuspendCellVoltage | read-write | mandatory | This is used along with the number of cells per battery and the number of batteries per string to determine if a battery string has violated the low voltage li… |
| 1.3.6.1.4.1.318.1.1.16.6.21 | ScalarbattManConfigOhmicTestWaitTime | read-write | mandatory | The amount of time in seconds after a discharge event before data will be collected for the ohmic value calculation. |
| 1.3.6.1.4.1.318.1.1.16.6.22 | ScalarbattManConfigNumberOfBoosts | read-write | mandatory | The number of consecutive times the Battery Management System applies a charge to each battery during a boost cycle. Batteries with a Rated Battery AH Capacity… |
| 1.3.6.1.4.1.318.1.1.16.7 | NodebattManAlarm | |||
| 1.3.6.1.4.1.318.1.1.16.7.1 | ScalarbattManAlarmManagementController | read-only | mandatory | The Management Controller Alarm is : normal(1) no alarm conditions identified alarm(2) an alarm condition exists. |
| 1.3.6.1.4.1.318.1.1.16.7.2 | ScalarbattManAlarmBatteries | read-only | mandatory | The Batteries Alarm is : normal(1) no alarm conditions identified alarm(2) an alarm condition exists. |
| 1.3.6.1.4.1.318.1.1.16.7.3 | ScalarbattManAlarmCharger | read-only | mandatory | The Charger Alarm is : normal(1) no alarm conditions identified alarm(2) an alarm condition exists. |
| 1.3.6.1.4.1.318.1.1.16.7.4 | ScalarbattManAlarmEnvironment | read-only | mandatory | The Environment Alarm is : normal(1) no alarm conditions identified alarm(2) an alarm condition exists. |
| 1.3.6.1.4.1.318.1.1.16.8 | NodebattManSystemStatus | |||
| 1.3.6.1.4.1.318.1.1.16.8.1 | ScalarbattManSystemAmbientTempC | read-only | mandatory | The system ambient temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.16.8.2 | ScalarbattManSystemAmbientTempF | read-only | mandatory | The system ambient temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.16.8.3 | ScalarbattManSystemPilotTempC | read-only | mandatory | The system pilot temperature in tenths of degrees Celsius. |
| 1.3.6.1.4.1.318.1.1.16.8.4 | ScalarbattManSystemPilotTempF | read-only | mandatory | The system pilot temperature in tenths of degrees Fahrenheit. |
| 1.3.6.1.4.1.318.1.1.16.8.5 | ScalarbattManSystemAmbientHighTempAlarm | read-only | mandatory | When set to alarm(2), indicates that the system has a high temperature alarm. |
| 1.3.6.1.4.1.318.1.1.16.8.6 | ScalarbattManSystemAmbientLowTempAlarm | read-only | mandatory | When set to alarm(2), indicates that the system has a low temperature alarm. |
| 1.3.6.1.4.1.318.1.1.16.8.7 | ScalarbattManSystemPilotBatteryHighTempAlarm | read-only | mandatory | When set to alarm(2), indicates that the system has a pilot battery high temperature alarm. |
| 1.3.6.1.4.1.318.1.1.16.8.8 | ScalarbattManSystemPilotProbeDisconnected | read-only | mandatory | When set to alarm(2), indicates that the system pilot probe is disconnected. |
| 1.3.6.1.4.1.318.1.1.16.8.9 | ScalarbattManSystemAmbientProbeDisconnected | read-only | mandatory | When set to alarm(2), indicates that the system ambient probe is disconnected. |
| 1.3.6.1.4.1.318.1.1.16.8.10 | ScalarbattManSystemConfigurationInvalid | read-only | mandatory | When set to alarm(2), indicates that the system is not configured correctly. |
| 1.3.6.1.4.1.318.1.1.16.8.11 | ScalarbattManSystemSuspendVoltage | read-only | mandatory | When set to alarm(2), indicates that the system has suspended voltage scans. |
| 1.3.6.1.4.1.318.1.1.16.9 | NodebattManStringStatus | |||
| 1.3.6.1.4.1.318.1.1.16.9.1 | ScalarbattManStringTableSize | read-only | mandatory | The number of entries in the battManStringTable. |
| 1.3.6.1.4.1.318.1.1.16.9.2 | TablebattManStringTable | not-accessible | mandatory | Allows for getting information from each string in the system. |
| 1.3.6.1.4.1.318.1.1.16.9.2.1 | RowbattManStringEntry | not-accessible | mandatory | The string to get data from. |
| 1.3.6.1.4.1.318.1.1.16.9.2.1.1 | ColumnbattManStringIndex | read-only | mandatory | Index of string entries in the table. |
| 1.3.6.1.4.1.318.1.1.16.9.2.1.2 | ColumnbattManStringCurrent | read-only | mandatory | The string current in tenths of amps. |
| 1.3.6.1.4.1.318.1.1.16.9.2.1.3 | ColumnbattManStringRippleCurrent | read-only | mandatory | The string ripple current in tenths of amps. |
| 1.3.6.1.4.1.318.1.1.16.9.2.1.4 | ColumnbattManStringChargerHighVoltageAlarm | read-only | mandatory | When set to alarm(2), indicates that the string charger has a high voltage alarm. |
| 1.3.6.1.4.1.318.1.1.16.9.2.1.5 | ColumnbattManStringChargerLowVoltageAlarm | read-only | mandatory | When set to alarm(2), indicates that the string charger has a low voltage alarm. |
| 1.3.6.1.4.1.318.1.1.16.9.2.1.6 | ColumnbattManStringCurrentProbeDisconnected | read-only | mandatory | When set to alarm(2), indicates that the string charger probe is disconnected. |
| 1.3.6.1.4.1.318.1.1.16.9.2.1.7 | ColumnbattManStringOnBattery | read-only | mandatory | When set to alarm(2), indicates that the string is in the on-battery state. |
| 1.3.6.1.4.1.318.1.1.16.9.2.1.8 | ColumnbattManStringHighRippleCurrent | read-only | mandatory | When set to alarm(2), indicates that the string has a high ripple current. |
| 1.3.6.1.4.1.318.1.1.16.9.2.1.9 | ColumnbattManStringVoltage | read-only | mandatory | The sum of the voltages for all of the batteries on a string in millivolts DC. |
| 1.3.6.1.4.1.318.1.1.16.9.2.1.10 | ColumnbattManStringDischargeLess5Seconds | read-only | mandatory | The number of recorded discharges lasting less than 5 seconds. |
| 1.3.6.1.4.1.318.1.1.16.9.2.1.11 | ColumnbattManStringDischarge5to10Seconds | read-only | mandatory | The number of recorded discharges lasting between 5 and 10 seconds. |
| 1.3.6.1.4.1.318.1.1.16.9.2.1.12 | ColumnbattManStringDischarge10to60Seconds | read-only | mandatory | The number of recorded discharges lasting between 10 and 60 seconds. |
| 1.3.6.1.4.1.318.1.1.16.9.2.1.13 | ColumnbattManStringDischargeMore60Seconds | read-only | mandatory | The number of recorded discharges lasting more than 60 seconds (1 minute). |
| 1.3.6.1.4.1.318.1.1.16.10 | NodebattManBatteryStatus | |||
| 1.3.6.1.4.1.318.1.1.16.10.1 | ScalarbattManString1BatteryTableSize | read-only | mandatory | The number of entries in the battManString1BatteryTable. |
| 1.3.6.1.4.1.318.1.1.16.10.2 | TablebattManString1BatteryTable | not-accessible | mandatory | Allows for getting information from each string in the system. |
| 1.3.6.1.4.1.318.1.1.16.10.2.1 | RowbattManString1BatteryEntry | not-accessible | mandatory | The string to get data from. |
| 1.3.6.1.4.1.318.1.1.16.10.2.1.1 | ColumnbattManString1BatteryIndex | read-only | mandatory | Index of string entries in the table. |
| 1.3.6.1.4.1.318.1.1.16.10.2.1.2 | ColumnbattManString1BatteryVoltage | read-only | mandatory | The battery voltage in millivolts DC. |
| 1.3.6.1.4.1.318.1.1.16.10.2.1.3 | ColumnbattManString1BatteryLowestVoltage | read-only | mandatory | The lowest battery discharge voltage during the last power event in millivolts DC. |
| 1.3.6.1.4.1.318.1.1.16.10.2.1.4 | ColumnbattManString1BatteryCellShorted | read-only | mandatory | When set to alarm(2), indicates that a battery cell is shorted. |
| 1.3.6.1.4.1.318.1.1.16.10.2.1.5 | ColumnbattManString1BatteryOpenFuseOrConnection | read-only | mandatory | When set to alarm(2), indicates that a fuse or connection is open. |
| 1.3.6.1.4.1.318.1.1.16.10.2.1.6 | ColumnbattManString1BatteryLowCapacity | read-only | mandatory | When set to alarm(2), indicates a battery has low capacity. |
| 1.3.6.1.4.1.318.1.1.16.10.2.1.7 | ColumnbattManString1BatteryHighOhmicValue | read-only | mandatory | When set to alarm(2), indicates a battery has a high ohmic value. |
| 1.3.6.1.4.1.318.1.1.16.10.2.1.8 | ColumnbattManString1BatteryThermalRunaway | read-only | mandatory | When set to alarm(2), indicates a battery has a thermal runaway condition. |
| 1.3.6.1.4.1.318.1.1.16.10.2.1.9 | ColumnbattManString1BatteryDryout | read-only | mandatory | When set to alarm(2), indicates a battery has a dryout condition. |
| 1.3.6.1.4.1.318.1.1.16.10.2.1.10 | ColumnbattManString1BatteryUserHighVoltageAlarm | read-only | mandatory | When set to alarm(2), indicates a battery has violated the user level high voltage limit. |
| 1.3.6.1.4.1.318.1.1.16.10.2.1.11 | ColumnbattManString1BatteryUserLowVoltageAlarm | read-only | mandatory | When set to alarm(2), indicates a battery has violated the user level low voltage limit. |
| 1.3.6.1.4.1.318.1.1.16.10.2.1.12 | ColumnbattManString1BatteryChemHighVoltageAlarm | read-only | mandatory | When set to alarm(2), indicates a battery has violated the chemistry level high voltage limit. |
| 1.3.6.1.4.1.318.1.1.16.10.2.1.13 | ColumnbattManString1BatteryChemLowVoltageAlarm | read-only | mandatory | When set to alarm(2), indicates a battery has violated the chemistry level low voltage limit. |
| 1.3.6.1.4.1.318.1.1.16.10.2.1.14 | ColumnbattManString1BatteryOpenCell | read-only | mandatory | When set to alarm(2), indicates the battery has an open cell or an inter-connection is abnormal. |
| 1.3.6.1.4.1.318.1.1.16.10.3 | ScalarbattManString2BatteryTableSize | read-only | mandatory | The number of entries in the battManString2BatteryTable. |
| 1.3.6.1.4.1.318.1.1.16.10.4 | TablebattManString2BatteryTable | not-accessible | mandatory | Allows for getting information from each string in the system. |
| 1.3.6.1.4.1.318.1.1.16.10.4.1 | RowbattManString2BatteryEntry | not-accessible | mandatory | The string to get data from. |
| 1.3.6.1.4.1.318.1.1.16.10.4.1.1 | ColumnbattManString2BatteryIndex | read-only | mandatory | Index of string entries in the table. |
| 1.3.6.1.4.1.318.1.1.16.10.4.1.2 | ColumnbattManString2BatteryVoltage | read-only | mandatory | The battery voltage in millivolts DC. |
| 1.3.6.1.4.1.318.1.1.16.10.4.1.3 | ColumnbattManString2BatteryLowestVoltage | read-only | mandatory | The lowest battery discharge voltage during the last power event in millivolts DC. |
| 1.3.6.1.4.1.318.1.1.16.10.4.1.4 | ColumnbattManString2BatteryCellShorted | read-only | mandatory | When set to alarm(2), indicates that a battery cell is shorted. |
| 1.3.6.1.4.1.318.1.1.16.10.4.1.5 | ColumnbattManString2BatteryOpenFuseOrConnection | read-only | mandatory | When set to alarm(2), indicates that a fuse or connection is open. |
| 1.3.6.1.4.1.318.1.1.16.10.4.1.6 | ColumnbattManString2BatteryLowCapacity | read-only | mandatory | When set to alarm(2), indicates a battery has low capacity. |
| 1.3.6.1.4.1.318.1.1.16.10.4.1.7 | ColumnbattManString2BatteryHighOhmicValue | read-only | mandatory | When set to alarm(2), indicates a battery has a high ohmic value. |
| 1.3.6.1.4.1.318.1.1.16.10.4.1.8 | ColumnbattManString2BatteryThermalRunaway | read-only | mandatory | When set to alarm(2), indicates a battery has a thermal runaway condition. |
| 1.3.6.1.4.1.318.1.1.16.10.4.1.9 | ColumnbattManString2BatteryDryout | read-only | mandatory | When set to alarm(2), indicates a battery has a dryout condition. |
| 1.3.6.1.4.1.318.1.1.16.10.4.1.10 | ColumnbattManString2BatteryUserHighVoltageAlarm | read-only | mandatory | When set to alarm(2), indicates a battery has violated the user level high voltage limit. |
| 1.3.6.1.4.1.318.1.1.16.10.4.1.11 | ColumnbattManString2BatteryUserLowVoltageAlarm | read-only | mandatory | When set to alarm(2), indicates a battery has violated the user level low voltage limit. |
| 1.3.6.1.4.1.318.1.1.16.10.4.1.12 | ColumnbattManString2BatteryChemHighVoltageAlarm | read-only | mandatory | When set to alarm(2), indicates a battery has violated the chemistry level high voltage limit. |
| 1.3.6.1.4.1.318.1.1.16.10.4.1.13 | ColumnbattManString2BatteryChemLowVoltageAlarm | read-only | mandatory | When set to alarm(2), indicates a battery has violated the chemistry level low voltage limit. |
| 1.3.6.1.4.1.318.1.1.16.10.4.1.14 | ColumnbattManString2BatteryOpenCell | read-only | mandatory | When set to alarm(2), indicates the battery has an open cell or an inter-connection is abnormal. |
| 1.3.6.1.4.1.318.1.1.16.11 | NodebattManInputContactStatus | |||
| 1.3.6.1.4.1.318.1.1.16.11.1 | ScalarbattManInputContactTableSize | read-only | mandatory | The number of entries in the battManInputContactTable. |
| 1.3.6.1.4.1.318.1.1.16.11.2 | TablebattManInputContactTable | not-accessible | mandatory | Allows for getting information from each contact in the system. |
| 1.3.6.1.4.1.318.1.1.16.11.2.1 | RowbattManInputContactEntry | not-accessible | mandatory | The contact to get data from. |
| 1.3.6.1.4.1.318.1.1.16.11.2.1.1 | ColumnbattManInputContactIndex | read-only | mandatory | Index of contact entries in the table. |
| 1.3.6.1.4.1.318.1.1.16.11.2.1.2 | ColumnbattManInputContactName | read-write | mandatory | The name of the input contact. |
| 1.3.6.1.4.1.318.1.1.16.11.2.1.3 | ColumnbattManInputContactAlarmState | read-only | mandatory | When set to alarm(2), indicates that the alarm condition is active for this contact. |
| 1.3.6.1.4.1.318.1.1.16.11.2.1.4 | ColumnbattManInputContactState | read-only | mandatory | When set to open(1), the input contact is in the open state. When set to closed(2), the input contact is in the closed state. |
| 1.3.6.1.4.1.318.1.1.16.11.2.1.5 | ColumnbattManInputContactNormalState | read-write | mandatory | When set to open(1), the input contact is normally open. When set to closed(2), the input contact is normally closed. |
| 1.3.6.1.4.1.318.1.1.16.11.2.1.6 | ColumnbattManInputContactAlarmDelay | read-write | mandatory | The input contact alarm delay time in seconds. |
| 1.3.6.1.4.1.318.1.1.16.12 | NodebattManControl | |||
| 1.3.6.1.4.1.318.1.1.16.12.1 | ScalarbattManRemoteAnnunciatorReset | read-write | mandatory | Setting this OID to reset(2) will reset the user interface annunciator. Getting this OID will do nothing and return the noOperation(1) value. |
| 1.3.6.1.4.1.318.1.1.16.12.2 | ScalarbattManResetChargeCurrentDeviationBenchmark | read-write | mandatory | Setting this OID to reset(2) will reset the charge current deviation benchmark. Getting this OID will do nothing and return the noOperation(1) value. |
| 1.3.6.1.4.1.318.1.1.16.12.3 | ScalarbattManResetLowestDischargeVoltages | read-write | mandatory | Setting this OID to reset(2) will reset the lowest discharge voltages. Getting this OID will do nothing and return the noOperation(1) value. |
| 1.3.6.1.4.1.318.1.1.16.12.4 | ScalarbattManResetDischargeCounters | read-write | mandatory | Setting this OID to reset(2) will reset all discharge event counters. Getting this OID will do nothing and return the noOperation(1) value. |
| 1.3.6.1.4.1.318.1.1.16.13 | NodebattManTestResults | |||
| 1.3.6.1.4.1.318.1.1.16.13.1 | ScalarbattManString1OhmicValueLastDischargeInfo | read-only | mandatory | Informational text showing the date/time, load, and pilot temperature for the string during the last discharge when ohmic values were recorded. |
| 1.3.6.1.4.1.318.1.1.16.13.2 | ScalarbattManString1OhmicValueTableSize | read-only | mandatory | The number of entries in the battManString1OhmicValueTable. |
| 1.3.6.1.4.1.318.1.1.16.13.3 | TablebattManString1OhmicValueTable | not-accessible | mandatory | Allows for getting ohmic value information from each battery in String 1. |
| 1.3.6.1.4.1.318.1.1.16.13.3.1 | RowbattManString1OhmicValueEntry | not-accessible | mandatory | The string to get data from. |
| 1.3.6.1.4.1.318.1.1.16.13.3.1.1 | ColumnbattManString1OhmicValueIndex | read-only | mandatory | The battery number. |
| 1.3.6.1.4.1.318.1.1.16.13.3.1.2 | ColumnbattManString1OhmicValueData | read-only | mandatory | The battery inter-tier ohmic value in ohms. Note: Zero or negative values are invalid and may indicate faulty calibration of ohmic value correction factors. |
| 1.3.6.1.4.1.318.1.1.16.13.4 | ScalarbattManString1ResponseTestChangeTableSize | read-only | mandatory | The number of entries in the battManString1ResponseTestChangeTable. |
| 1.3.6.1.4.1.318.1.1.16.13.5 | TablebattManString1ResponseTestChangeTable | not-accessible | mandatory | Allows for getting response test change information from each battery in String 1. |
| 1.3.6.1.4.1.318.1.1.16.13.5.1 | RowbattManString1ResponseTestChangeEntry | not-accessible | mandatory | The string to get data from. |
| 1.3.6.1.4.1.318.1.1.16.13.5.1.1 | ColumnbattManString1ResponseTestChangeIndex | read-only | mandatory | Index of the entries in the table. |
| 1.3.6.1.4.1.318.1.1.16.13.5.1.2 | ColumnbattManString1ResponseTestChangeData | read-only | mandatory | The battery response test change in percent. |
| 1.3.6.1.4.1.318.1.1.16.13.6 | ScalarbattManString2OhmicValueLastDischargeInfo | read-only | mandatory | Informational text showing the date/time, load, and pilot temperature for the string during the last discharge when ohmic values were recorded. |
| 1.3.6.1.4.1.318.1.1.16.13.7 | ScalarbattManString2OhmicValueTableSize | read-only | mandatory | The number of entries in the battManString2OhmicValueTable. |
| 1.3.6.1.4.1.318.1.1.16.13.8 | TablebattManString2OhmicValueTable | not-accessible | mandatory | Allows for getting ohmic value information from each battery in String 2. |
| 1.3.6.1.4.1.318.1.1.16.13.8.1 | RowbattManString2OhmicValueEntry | not-accessible | mandatory | The string to get data from. |
| 1.3.6.1.4.1.318.1.1.16.13.8.1.1 | ColumnbattManString2OhmicValueIndex | read-only | mandatory | Index of battery calibration entries in the table. |
| 1.3.6.1.4.1.318.1.1.16.13.8.1.2 | ColumnbattManString2OhmicValueData | read-only | mandatory | The battery inter-tier ohmic value in ohms. Note: Zero or negative values are invalid and may indicate faulty calibration of ohmic value correction factors. |
| 1.3.6.1.4.1.318.1.1.16.13.9 | ScalarbattManString2ResponseTestChangeTableSize | read-only | mandatory | The number of entries in the battManString2ResponseTestChangeTable. |
| 1.3.6.1.4.1.318.1.1.16.13.10 | TablebattManString2ResponseTestChangeTable | not-accessible | mandatory | Allows for getting response test change information from each battery in String 2. |
| 1.3.6.1.4.1.318.1.1.16.13.10.1 | RowbattManString2ResponseTestChangeEntry | not-accessible | mandatory | The string to get data from. |
| 1.3.6.1.4.1.318.1.1.16.13.10.1.1 | ColumnbattManString2ResponseTestChangeIndex | read-only | mandatory | Index of the entries in the table. |
| 1.3.6.1.4.1.318.1.1.16.13.10.1.2 | ColumnbattManString2ResponseTestChangeData | read-only | mandatory | The battery response test change in percent. |
| 1.3.6.1.4.1.318.1.1.16.13.11 | ScalarbattManString1ResponseTestCurrentTableSize | read-only | mandatory | The number of entries in the battManString1ResponseTestCurrentTable. |
| 1.3.6.1.4.1.318.1.1.16.13.12 | TablebattManString1ResponseTestCurrentTable | not-accessible | mandatory | Allows for getting response test current information from each battery in String 1. |
| 1.3.6.1.4.1.318.1.1.16.13.12.1 | RowbattManString1ResponseTestCurrentEntry | not-accessible | mandatory | The string to get data from. |
| 1.3.6.1.4.1.318.1.1.16.13.12.1.1 | ColumnbattManString1ResponseTestCurrentIndex | read-only | mandatory | Index of the entries in the table. |
| 1.3.6.1.4.1.318.1.1.16.13.12.1.2 | ColumnbattManString1ResponseTestCurrentData | read-only | mandatory | The battery response test current in milliamps. |
| 1.3.6.1.4.1.318.1.1.16.13.13 | ScalarbattManString2ResponseTestCurrentTableSize | read-only | mandatory | The number of entries in the battManString2ResponseTestCurrentTable. |
| 1.3.6.1.4.1.318.1.1.16.13.14 | TablebattManString2ResponseTestCurrentTable | not-accessible | mandatory | Allows for getting response test current information from each battery in String 2. |
| 1.3.6.1.4.1.318.1.1.16.13.14.1 | RowbattManString2ResponseTestCurrentEntry | not-accessible | mandatory | The string to get data from. |
| 1.3.6.1.4.1.318.1.1.16.13.14.1.1 | ColumnbattManString2ResponseTestCurrentIndex | read-only | mandatory | Index of the entries in the table. |
| 1.3.6.1.4.1.318.1.1.16.13.14.1.2 | ColumnbattManString2ResponseTestCurrentData | read-only | mandatory | The battery response test current in milliamps. |
| 1.3.6.1.4.1.318.1.1.16.13.15 | ScalarbattManString1ResponseTestCurrentBenchmarkTableSize | read-only | mandatory | The number of entries in the battManString1ResponseTestCurrentBenchmarkTable. |
| 1.3.6.1.4.1.318.1.1.16.13.16 | TablebattManString1ResponseTestCurrentBenchmarkTable | not-accessible | mandatory | Allows for getting response test current benchmark information from each battery in String 1. |
| 1.3.6.1.4.1.318.1.1.16.13.16.1 | RowbattManString1ResponseTestCurrentBenchmarkEntry | not-accessible | mandatory | The string to get data from. |
| 1.3.6.1.4.1.318.1.1.16.13.16.1.1 | ColumnbattManString1ResponseTestCurrentBenchmarkIndex | read-only | mandatory | Index of the entries in the table. |
| 1.3.6.1.4.1.318.1.1.16.13.16.1.2 | ColumnbattManString1ResponseTestCurrentBenchmarkData | read-only | mandatory | The battery response test current benchmark in milliamps. |
| 1.3.6.1.4.1.318.1.1.16.13.17 | ScalarbattManString2ResponseTestCurrentBenchmarkTableSize | read-only | mandatory | The number of entries in the battManString2ResponseTestCurrentBenchmarkTable. |
| 1.3.6.1.4.1.318.1.1.16.13.18 | TablebattManString2ResponseTestCurrentBenchmarkTable | not-accessible | mandatory | Allows for getting response test current benchmark information from each battery in String 2. |
| 1.3.6.1.4.1.318.1.1.16.13.18.1 | RowbattManString2ResponseTestCurrentBenchmarkEntry | not-accessible | mandatory | The string to get data from. |
| 1.3.6.1.4.1.318.1.1.16.13.18.1.1 | ColumnbattManString2ResponseTestCurrentBenchmarkIndex | read-only | mandatory | Index of the entries in the table. |
| 1.3.6.1.4.1.318.1.1.16.13.18.1.2 | ColumnbattManString2ResponseTestCurrentBenchmarkData | read-only | mandatory | The battery response test current benchmark in milliamps. |
| 1.3.6.1.4.1.318.1.1.16.14 | NodebattManUnitStatus | |||
| 1.3.6.1.4.1.318.1.1.16.14.1 | ScalarbattManUnitStatusTableSize | read-only | mandatory | The number of entries in the battManUnitStatusTable. |
| 1.3.6.1.4.1.318.1.1.16.14.2 | TablebattManUnitStatusTable | not-accessible | mandatory | Allows for getting status information from each unit in the system. |
| 1.3.6.1.4.1.318.1.1.16.14.2.1 | RowbattManUnitStatusEntry | not-accessible | mandatory | The unit to get data from. |
| 1.3.6.1.4.1.318.1.1.16.14.2.1.1 | ColumnbattManUnitStatusIndex | read-only | mandatory | Index of unit status entries in the table. |
| 1.3.6.1.4.1.318.1.1.16.14.2.1.2 | ColumnbattManUnitStatusSerialNumber | read-only | mandatory | The battery manager unit serial number character string. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.16.14.2.1.3 | ColumnbattManUnitHardwareRev | read-only | mandatory | The battery manager unit hardware revision. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.16.14.2.1.4 | ColumnbattManUnitFirmwareRev | read-only | mandatory | The battery manager unit firmware revision. This value is set at the factory and can change with firmware update. |
| 1.3.6.1.4.1.318.1.1.16.14.2.1.5 | ColumnbattManUnitCommLoss | read-only | mandatory | When set to alarm(2), indicates the system has lost communication with the unit. |
| 1.3.6.1.4.1.318.1.1.16.14.2.1.6 | ColumnbattManUnitRelayStuck | read-only | mandatory | When set to alarm(2), indicates the unit monitor relay is stuck. |
| 1.3.6.1.4.1.318.1.1.17 | NodexATS | |||
| 1.3.6.1.4.1.318.1.1.17.1 | NodexATSIdent | |||
| 1.3.6.1.4.1.318.1.1.17.1.1 | ScalarxATSIdentProductName | read-write | mandatory | The name of the transfer switch unit. |
| 1.3.6.1.4.1.318.1.1.17.1.2 | ScalarxATSIdentHardwareRev | read-only | mandatory | The hardware revision of the transfer switch. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.17.1.3 | ScalarxATSIdentFirmwareAppRev | read-only | mandatory | An ID string identifying the application firmware revision of the transfer switch. |
| 1.3.6.1.4.1.318.1.1.17.1.4 | ScalarxATSIdentFirmwareAppOSRev | read-only | mandatory | An ID string identifying the application operating system firmware revision of the transfer switch. |
| 1.3.6.1.4.1.318.1.1.17.1.5 | ScalarxATSIdentFirmwareControllerRev | read-only | mandatory | An ID string identifying the transfer switch controller firmware revision. |
| 1.3.6.1.4.1.318.1.1.17.1.6 | ScalarxATSIdentDateOfManufacture | read-only | mandatory | The date when the transfer switch was manufactured in mm/dd/yyyy format. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.17.1.7 | ScalarxATSIdentModelNumber | read-only | mandatory | A character string identifying the model number of the transfer switch. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.17.1.8 | ScalarxATSIdentSerialNumber | read-only | mandatory | A character string identifying the serial number of the transfer switch. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.17.2 | NodexATSDevice | |||
| 1.3.6.1.4.1.318.1.1.17.2.1 | ScalarxATSDeviceServiceType | read-only | mandatory | The type of utility input to the transfer switch. Either 3 wires (delta), or 4 wires (wye). |
| 1.3.6.1.4.1.318.1.1.17.2.2 | ScalarxATSDeviceNominalVoltage | read-only | mandatory | The nominal line-to-neutral system voltage. Measured in Volts, line-to-line for a 3-wire service or line-to-neutral for a 4-wire service. -1 if not available. |
| 1.3.6.1.4.1.318.1.1.17.2.3 | ScalarxATSDeviceNominalFrequency | read-only | mandatory | The nominal system frequency. Measured in tenths of Hertz. -1 if not available. |
| 1.3.6.1.4.1.318.1.1.17.2.4 | ScalarxATSDeviceTransferSwitchRating | read-only | mandatory | The rating of the transfer switch. Measured in Amps. |
| 1.3.6.1.4.1.318.1.1.17.2.5 | ScalarxATSDeviceDCBackUpPresent | read-write | mandatory | Indicates if a DC backup is present or not. |
| 1.3.6.1.4.1.318.1.1.17.3 | NodexATSSwitch | |||
| 1.3.6.1.4.1.318.1.1.17.3.1 | NodexATSSwitchStatus | |||
| 1.3.6.1.4.1.318.1.1.17.3.1.1 | ScalarxATSSwitchStatusSelectedSource | read-only | mandatory | The source which is currently selected, i.e. supplying power to the load. |
| 1.3.6.1.4.1.318.1.1.17.3.1.2 | ScalarxATSSwitchStatusOperationalMode | read-only | mandatory | The current operating mode of the transfer switch. When the ATS is in automatic mode, generator starting and ATS transferring is all done automatically as need… |
| 1.3.6.1.4.1.318.1.1.17.3.1.3 | ScalarxATSSwitchStatusAutomaticOperationSwitch | read-only | mandatory | The position of the automatic operation switch on the front of the transfer switch. |
| 1.3.6.1.4.1.318.1.1.17.3.1.4 | ScalarxATSSwitchStatusEngineStartSignal | read-only | mandatory | The position of the Start/Stop contact which signals the generator engine to start/run. When the ATS is in automatic mode, generator starting/stopping is under… |
| 1.3.6.1.4.1.318.1.1.17.3.2 | NodexATSSwitchSettings | |||
| 1.3.6.1.4.1.318.1.1.17.3.2.1 | ScalarxATSSwitchSettingsLowVoltageTransferPoint | read-write | mandatory | The lowest acceptable voltage condition at source 1. When any phase of source 1 is lower than this voltage, source quality is considered bad and the generator … |
| 1.3.6.1.4.1.318.1.1.17.3.2.2 | ScalarxATSSwitchSettingsHighVoltageTransferPoint | read-write | mandatory | The highest acceptable voltage condition at source 1. When any phase of source 1 is greater than this voltage, source quality is considered bad and the generat… |
| 1.3.6.1.4.1.318.1.1.17.3.2.3 | ScalarxATSSwitchSettingsMaxFrequencyDeviation | read-write | mandatory | The maximum acceptable frequency deviation condition from nominal at source 1. When source 1 frequency is outside the specified range, source quality is consid… |
| 1.3.6.1.4.1.318.1.1.17.3.2.4 | ScalarxATSSwitchSettingsMinPhaseBalance | read-write | mandatory | The minimum required phase balance at source 1. When the percentage difference between the minimum and maximum phase voltage measurements at source 1 is greate… |
| 1.3.6.1.4.1.318.1.1.17.3.2.5 | ScalarxATSSwitchSettingsNominalRotation | read-write | mandatory | The nominal phase rotation (or phase sequence) required by the load. For certain types of equipment, such as rotating machinery, phase rotation is critical for… |
| 1.3.6.1.4.1.318.1.1.17.3.2.6 | ScalarxATSSwitchSettingsAllowClosedTransfer | read-write | mandatory | This setting enables seamless (closed) transfers between sources. When possible, both source 1 and source 2 are closed to the output for a brief time. If close… |
| 1.3.6.1.4.1.318.1.1.17.3.2.7 | ScalarxATSSwitchSettingsMaxSyncTime | read-write | mandatory | When attempting/seeking to perform a closed transfer, this setting defines the maximum time allowed before the transfer switch will give up and perform an open… |
| 1.3.6.1.4.1.318.1.1.17.3.2.8 | ScalarxATSSwitchSettingsNeutralTransferTime | read-write | mandatory | This setting defines how long both source 1 and source 2 will be disconnected from the output, during an open transfer. Specified in seconds. -1 if not availab… |
| 1.3.6.1.4.1.318.1.1.17.3.2.9 | ScalarxATSSwitchSettingsClearLatchedAlarms | read-write | mandatory | Clears any latched alarm conditions. |
| 1.3.6.1.4.1.318.1.1.17.3.2.10 | ScalarxATSSwitchSettingsSetToFactoryDefaults | read-write | mandatory | Sets all transfer switch settings to factory default values. |
| 1.3.6.1.4.1.318.1.1.17.3.3 | NodexATSSwitchTimers | |||
| 1.3.6.1.4.1.318.1.1.17.3.3.1 | ScalarxATSSwitchTimersTableSize | read-only | mandatory | The number of transfer switch timer entries. |
| 1.3.6.1.4.1.318.1.1.17.3.3.2 | TablexATSSwitchTimersTable | not-accessible | mandatory | A list of timers supported by ATS. The number of entries is contained in the xATSSwitchTimersTableSize OID. |
| 1.3.6.1.4.1.318.1.1.17.3.3.2.1 | RowxATSSwitchTimersEntry | not-accessible | mandatory | An entry containing information about an individual ATS timer. |
| 1.3.6.1.4.1.318.1.1.17.3.3.2.1.1 | ColumnxATSSwitchTimersIndex | read-only | mandatory | Index of timer entries in the table. |
| 1.3.6.1.4.1.318.1.1.17.3.3.2.1.2 | ColumnxATSSwitchTimersName | read-only | mandatory | Name of the individual timer.Refer to ATS operation manual, or on-line help, for detailed descriptions of ATS timers. |
| 1.3.6.1.4.1.318.1.1.17.3.3.2.1.3 | ColumnxATSSwitchTimersAbort | read-write | mandatory | This aborts the individual timer. |
| 1.3.6.1.4.1.318.1.1.17.3.3.2.1.4 | ColumnxATSSwitchTimersStatus | read-only | mandatory | The status of the individual timer. Designates whether this timer entry is currently running or inactive. |
| 1.3.6.1.4.1.318.1.1.17.3.3.2.1.5 | ColumnxATSSwitchTimersRemainingTime | read-only | mandatory | The time remaining for this timer entry. Specified in seconds. |
| 1.3.6.1.4.1.318.1.1.17.3.3.2.1.6 | ColumnxATSSwitchTimersDelaySetting | read-write | mandatory | The delay settings associated with this timer entry. When this timer entry is active, the timer value must exceed this setting before the ATS behavior associat… |
| 1.3.6.1.4.1.318.1.1.17.3.4 | NodexATSSwitchBlockMap | |||
| 1.3.6.1.4.1.318.1.1.17.3.4.1 | ScalarxATSSwitchBlockMapTableSize | read-only | mandatory | The number of blocking map entries, or how many ATS actions can be blocked. |
| 1.3.6.1.4.1.318.1.1.17.3.4.2 | TablexATSSwitchBlockMapTable | not-accessible | mandatory | A list of blocking maps supported by the ATS. The number of entries is contained in the xATSSwitchBlockMapTableSize OID. |
| 1.3.6.1.4.1.318.1.1.17.3.4.2.1 | RowxATSSwitchBlockMapEntry | not-accessible | mandatory | An entry containing information about a specific ATS blocking map. |
| 1.3.6.1.4.1.318.1.1.17.3.4.2.1.1 | ColumnxATSSwitchBlockMapIndex | read-only | mandatory | Index of blocking map entries in the table. |
| 1.3.6.1.4.1.318.1.1.17.3.4.2.1.2 | ColumnxATSSwitchBlockMapName | read-only | mandatory | A string describing the ATS action to be blocked. |
| 1.3.6.1.4.1.318.1.1.17.3.4.2.1.3 | ColumnxATSSwitchBlockMapStatus | read-only | mandatory | Represents the status of this blocking map entry, in bit-mapped format. A non-zero value indicates that this entry's ATS action is currently being blocked. The… |
| 1.3.6.1.4.1.318.1.1.17.3.4.2.1.4 | ColumnxATSSwitchBlockMapSetting | read-write | mandatory | This setting designates the inputs that block the ATS action The mapping is specified as a bit-field, where each bit set indicates the input that blocks the AT… |
| 1.3.6.1.4.1.318.1.1.17.3.5 | NodexATSSwitchStatistics | |||
| 1.3.6.1.4.1.318.1.1.17.3.5.1 | ScalarxATSSwitchStatisticsTableSize | read-only | mandatory | The number of transfer switch statistics entries. |
| 1.3.6.1.4.1.318.1.1.17.3.5.2 | TablexATSSwitchStatisticsTable | not-accessible | mandatory | A list of statistics supported by ATS. The number of entries is contained in the xATSSwitchStatisticsTableSize OID. |
| 1.3.6.1.4.1.318.1.1.17.3.5.2.1 | RowxATSSwitchStatisticsEntry | not-accessible | mandatory | An entry containing information about an individual ATS statistic. |
| 1.3.6.1.4.1.318.1.1.17.3.5.2.1.1 | ColumnxATSSwitchStatisticsIndex | read-only | mandatory | Index of ATS statistics entries in the table. |
| 1.3.6.1.4.1.318.1.1.17.3.5.2.1.2 | ColumnxATSSwitchStatisticsName | read-only | mandatory | This is the name of the ATS statistic associated with this entry. |
| 1.3.6.1.4.1.318.1.1.17.3.5.2.1.3 | ColumnxATSSwitchStatisticsValue | read-only | mandatory | This is the value of the ATS statistic associated with this entry. |
| 1.3.6.1.4.1.318.1.1.17.3.5.2.1.4 | ColumnxATSSwitchStatisticsReset | read-write | mandatory | This will reset the individual ATS statistic associated with this entry. |
| 1.3.6.1.4.1.318.1.1.17.4 | NodexATSACMonitoringPoint | |||
| 1.3.6.1.4.1.318.1.1.17.4.1 | NodexATSSource1 | |||
| 1.3.6.1.4.1.318.1.1.17.4.1.1 | ScalarxATSSource1Name | read-write | mandatory | String used to identify source 1. |
| 1.3.6.1.4.1.318.1.1.17.4.1.2 | ScalarxATSSource1Position | read-only | mandatory | The current position of the switch at source 1. |
| 1.3.6.1.4.1.318.1.1.17.4.1.3 | ScalarxATSSource1Frequency | read-only | mandatory | The frequency at source 1 in tenths of Hertz. -1 if unavailable. |
| 1.3.6.1.4.1.318.1.1.17.4.1.4 | ScalarxATSSource1Quality | read-only | mandatory | The current line quality of source 1. |
| 1.3.6.1.4.1.318.1.1.17.4.1.5 | ScalarxATSSource1Rotation | read-only | mandatory | The phase rotation measured at the source 1 input of the ATS. The sequence is a reference to the order in which the three phases pass the zero-crossing boundar… |
| 1.3.6.1.4.1.318.1.1.17.4.1.6 | ScalarxATSSource1TableSize | read-only | mandatory | The number of input voltage entries at the source 1 input of the ATS. |
| 1.3.6.1.4.1.318.1.1.17.4.1.7 | TablexATSSource1PhaseTable | not-accessible | mandatory | A list of voltage table entries for source 1. The number of entries are the phase entries. The number of entries is contained in the xATSSource1TableSize OID. |
| 1.3.6.1.4.1.318.1.1.17.4.1.7.1 | RowxATSSource1PhaseEntry | not-accessible | mandatory | An entry containing information applicable to a particular input voltage phase at the source 1 input of the ATS. |
| 1.3.6.1.4.1.318.1.1.17.4.1.7.1.1 | ColumnxATSSource1Index | read-only | mandatory | Description of each phase utilized at source 1. |
| 1.3.6.1.4.1.318.1.1.17.4.1.7.1.2 | ColumnxATSSource1VoltageLtoL | read-only | mandatory | Source 1 line-to-line input voltage. Measured in tenths of Volts. |
| 1.3.6.1.4.1.318.1.1.17.4.1.7.1.3 | ColumnxATSSource1VoltageLtoN | read-only | mandatory | Source 1 line-to-neutral input voltage. Measured in tenths of Volts. -1 for a 3-wire service type. |
| 1.3.6.1.4.1.318.1.1.17.4.2 | NodexATSSource2 | |||
| 1.3.6.1.4.1.318.1.1.17.4.2.1 | ScalarxATSSource2Name | read-write | mandatory | String used to identify source 2. |
| 1.3.6.1.4.1.318.1.1.17.4.2.2 | ScalarxATSSource2Position | read-only | mandatory | The current position of the switch at source 2. |
| 1.3.6.1.4.1.318.1.1.17.4.2.3 | ScalarxATSSource2Frequency | read-only | mandatory | The frequency at source 2 in tenths of Hertz. -1 if not available. |
| 1.3.6.1.4.1.318.1.1.17.4.2.4 | ScalarxATSSource2Quality | read-only | mandatory | The current line quality of source 2. |
| 1.3.6.1.4.1.318.1.1.17.4.2.5 | ScalarxATSSource2Rotation | read-only | mandatory | The phase rotation measured at the source 2 input of the ATS. -1 if not available. |
| 1.3.6.1.4.1.318.1.1.17.4.2.6 | ScalarxATSSource2TableSize | read-only | mandatory | The number of input voltage entries at the source 2 input of the ATS. |
| 1.3.6.1.4.1.318.1.1.17.4.2.7 | TablexATSSource2PhaseTable | not-accessible | mandatory | A list of voltage table entries for the source 2. The number of entries are the phase entries. The number of entries is contained in the xATSSource2TableSize O… |
| 1.3.6.1.4.1.318.1.1.17.4.2.7.1 | RowxATSSource2PhaseEntry | not-accessible | mandatory | An entry containing information applicable to a particular input voltage phase at the source 2 input of the ATS. |
| 1.3.6.1.4.1.318.1.1.17.4.2.7.1.1 | ColumnxATSSource2Index | read-only | mandatory | Description of each phase utilized at the source 2. |
| 1.3.6.1.4.1.318.1.1.17.4.2.7.1.2 | ColumnxATSSource2VoltageLtoL | read-only | mandatory | Source 2 line-to-line input voltage. Measured in tenths of Volts. |
| 1.3.6.1.4.1.318.1.1.17.4.2.7.1.3 | ColumnxATSSource2VoltageLtoN | read-only | mandatory | Source 2 line-to-neutral input voltage. Measured in tenths of Volts. -1 for a 3-wire service type. |
| 1.3.6.1.4.1.318.1.1.17.4.3 | NodexATSSystemOutput | |||
| 1.3.6.1.4.1.318.1.1.17.4.3.1 | ScalarxATSSystemOutputFrequency | read-only | mandatory | The system output frequency in tenths of Hertz. |
| 1.3.6.1.4.1.318.1.1.17.4.3.2 | ScalarxATSSystemOutputTotalPower | read-only | mandatory | Shows the total system output power in tenths of kW. |
| 1.3.6.1.4.1.318.1.1.17.4.3.3 | ScalarxATSSystemOutputTotalApparentPower | read-only | mandatory | Shows the total system output power in tenths of kVA. |
| 1.3.6.1.4.1.318.1.1.17.4.3.4 | ScalarxATSSystemOutputTotalPowerFactor | read-only | mandatory | Indicates the total power factor of the system output. A value of 100 representing a unity power factor (1.00) Specified in hundredths. |
| 1.3.6.1.4.1.318.1.1.17.4.3.5 | ScalarxATSSystemOutputFrequencyTolerance | read-write | mandatory | Shows the panel output frequency tolerance in +/- Hertz. |
| 1.3.6.1.4.1.318.1.1.17.4.3.6 | ScalarxATSSystemOutputOverVoltThreshold | read-write | mandatory | Threshold above which an output over voltage condition will be generated. Specified as tenths of percent deviation from nominal. A value of zero indicates that… |
| 1.3.6.1.4.1.318.1.1.17.4.3.7 | ScalarxATSSystemOutputUnderVoltThreshold | read-write | mandatory | Threshold below which an output under voltage condition will be generated. Specified as tenths of percent deviation from nominal. A value of zero indicates tha… |
| 1.3.6.1.4.1.318.1.1.17.4.3.8 | ScalarxATSSystemOutputOverCurrentThreshold | read-write | mandatory | Threshold above which an over current condition will be generated. Specified as a percent of the transfer switch rating (xATSDeviceTransferSwitchRating OID). A… |
| 1.3.6.1.4.1.318.1.1.17.4.3.9 | ScalarxATSSystemOutputUnderCurrentThreshold | read-write | mandatory | Threshold below which an under current condition will be generated. Specified as a percent of the transfer switch rating (xATSDeviceTransferSwitchRating OID). … |
| 1.3.6.1.4.1.318.1.1.17.4.3.10 | ScalarxATSSystemOutputAlarmDelayThreshold | read-write | mandatory | Delay the generation of an output alarm. Specified in seconds. |
| 1.3.6.1.4.1.318.1.1.17.4.3.11 | ScalarxATSSystemOutputTableSize | read-only | mandatory | The number of system output phase entries. |
| 1.3.6.1.4.1.318.1.1.17.4.3.12 | TablexATSSystemOutputPhaseTable | not-accessible | mandatory | A list of system output table entries. The number of entries is contained in the xATSSystemOutputTableSize OID. |
| 1.3.6.1.4.1.318.1.1.17.4.3.12.1 | RowxATSSystemOutputPhaseEntry | not-accessible | mandatory | An entry containing information applicable to a particular system output phase. |
| 1.3.6.1.4.1.318.1.1.17.4.3.12.1.1 | ColumnxATSSystemOutputPhaseIndex | read-only | mandatory | Description of each system output phase utilized in this device. |
| 1.3.6.1.4.1.318.1.1.17.4.3.12.1.2 | ColumnxATSSystemOutputVoltageLtoL | read-only | mandatory | Line-to-line system output voltage available at the circuit panel. Measured in tenths of Volts. -1 if not available. |
| 1.3.6.1.4.1.318.1.1.17.4.3.12.1.3 | ColumnxATSSystemOutputVoltageLtoN | read-only | mandatory | Line-to-neutral system output voltage available at the circuit panel. Measured in tenths of Volts. -1 for a 3-wire service type or if not available. |
| 1.3.6.1.4.1.318.1.1.17.4.3.12.1.4 | ColumnxATSSystemOutputPhaseCurrent | read-only | mandatory | System load current per phase. Measured in Amps. -1 if not available. |
| 1.3.6.1.4.1.318.1.1.17.4.3.12.1.5 | ColumnxATSSystemOutputPower | read-only | mandatory | System output power per phase. Measured in tenths of kW. |
| 1.3.6.1.4.1.318.1.1.17.4.3.12.1.6 | ColumnxATSSystemOutputApparentPower | read-only | mandatory | system output power per phase. Measured in tenths of kVA. |
| 1.3.6.1.4.1.318.1.1.17.4.3.12.1.7 | ColumnxATSSystemOutputPowerFactor | read-only | mandatory | indicates the power factor of the system output per phase. A value of 100 representing a unity power factor (1.00). Measured in hundredths. |
| 1.3.6.1.4.1.318.1.1.17.5 | NodexATSTesting | |||
| 1.3.6.1.4.1.318.1.1.17.5.1 | NodexATSTestingStatus | |||
| 1.3.6.1.4.1.318.1.1.17.5.1.1 | ScalarxATSTestingStatusSelectTestProcess | read-write | mandatory | Type of tests that can be selected when no test has been scheduled. engineStartTest and systemLoadTest may be selected when no tests are running. Tests that ar… |
| 1.3.6.1.4.1.318.1.1.17.5.1.2 | ScalarxATSTestingStatusTestStatus | read-only | mandatory | The present system test status/state. |
| 1.3.6.1.4.1.318.1.1.17.5.1.3 | ScalarxATSTestingStatusProfileWarmupTime | read-write | mandatory | The amount of time that the generator will warm up during a test. This is portion of the test when the xATSTestingStatusTestStatus OID returns the value engine… |
| 1.3.6.1.4.1.318.1.1.17.5.1.4 | ScalarxATSTestingStatusProfileLoadedTime | read-write | mandatory | The amount of time that ATS will apply the system load to the generator during a system load test. This is portion of the test when the xATSTestingStatusTestSt… |
| 1.3.6.1.4.1.318.1.1.17.5.1.5 | ScalarxATSTestingStatusProfileUnloadedTime | read-write | mandatory | The amount of time that the generator will run following the warm up portion of a start test, or the loaded portion of a load test. This is portion of the test… |
| 1.3.6.1.4.1.318.1.1.17.5.2 | NodexATSTestingResults | |||
| 1.3.6.1.4.1.318.1.1.17.5.2.1 | ScalarxATSTestingResultsLastDateOfTest | read-only | mandatory | Date of the last test that was performed, either scheduled or manual. Test results are available in the xATSTestingResultsLastResult OID. Specified in the dd/m… |
| 1.3.6.1.4.1.318.1.1.17.5.2.2 | ScalarxATSTestingResultsLastResult | read-only | mandatory | The result of the last ATS/generator system test. |
| 1.3.6.1.4.1.318.1.1.17.5.2.3 | ScalarxATSTestingResultsTestLastTestTime | read-only | mandatory | Time of day at which the last test was performed, either scheduled or manual. Test results are available in the xATSTestingResultsLastResult OID. Specified in … |
| 1.3.6.1.4.1.318.1.1.17.5.2.4 | ScalarxATSTestingResultsLastCrankDuration | read-only | mandatory | The time spent cranking the generator before it started during the last test. Specified in seconds, or -1 if not available. |
| 1.3.6.1.4.1.318.1.1.17.5.2.5 | ScalarxATSTestingResultsLastWarmupDuration | read-only | mandatory | The time spent in the engineWarmingUp state during the last system test. Specified in seconds, or -1 if not available. |
| 1.3.6.1.4.1.318.1.1.17.5.2.6 | ScalarxATSTestingResultsLastLoadedDuration | read-only | mandatory | The time spent in the testingWithLoad state during the last system test. Specified in seconds, or -1 if not available. |
| 1.3.6.1.4.1.318.1.1.17.5.2.7 | ScalarxATSTestingResultsLastUnloadedDuration | read-only | mandatory | The time spent in the testingWithoutLoad state during the last system test. Specified in seconds, or -1 if not available. |
| 1.3.6.1.4.1.318.1.1.17.5.3 | NodexATSTestingSchedule | |||
| 1.3.6.1.4.1.318.1.1.17.5.3.1 | ScalarxATSTestingScheduleFrequency | read-write | mandatory | The frequency of running scheduled tests. |
| 1.3.6.1.4.1.318.1.1.17.5.3.2 | ScalarxATSTestingScheduleTestDay | read-write | mandatory | The desired day for the scheduled test. This object applies only when the xATSTestingScheduleFrequency OID is set to weekly or monthly. For weekly test frequen… |
| 1.3.6.1.4.1.318.1.1.17.5.3.3 | ScalarxATSTestingScheduleTestTime | read-write | mandatory | The time of day that the scheduled test will occur. Specified in the format hh:mm. |
| 1.3.6.1.4.1.318.1.1.17.5.3.4 | ScalarxATSTestingScheduleTestWithLoadInterval | read-write | mandatory | This setting specifies which system tests should include applying the load to the generator. The applyLoadMonthlyDetailed entry in the list will apply load onc… |
| 1.3.6.1.4.1.318.1.1.17.5.3.5 | ScalarxATSTestingScheduleTestWithLoadSelectMonth | read-write | mandatory | The detailed selection for testing with load on a month-by-month basis. This object is applicable when the xATSTestingScheduleTestWithLoadInterval is set to ap… |
| 1.3.6.1.4.1.318.1.1.17.5.3.6 | ScalarxATSTestingScheduleNextTestDate | read-only | mandatory | The date of the next scheduled test, in the format dd-mmm-yyyy. |
| 1.3.6.1.4.1.318.1.1.17.5.4 | NodexATSTestingSimulatePowerFail | |||
| 1.3.6.1.4.1.318.1.1.17.5.4.1 | ScalarxATSTestingSimulatePowerFailTest | read-write | mandatory | This object executes a simulated power failure for the duration indicated. Simulation can be aborted by selecting cancelSimulation. |
| 1.3.6.1.4.1.318.1.1.17.5.4.2 | ScalarxATSTestingSimulatePowerFailTimeRemaining | read-only | mandatory | Indicates the time remaining in seconds, for a simulated power failure. a value of zero indicates that simulated power failure is not active. |
| 1.3.6.1.4.1.318.1.1.17.6 | NodexATSInputContacts | |||
| 1.3.6.1.4.1.318.1.1.17.6.1 | ScalarxATSInputContactNumContacts | read-only | mandatory | The number of contacts supported by the ATS. |
| 1.3.6.1.4.1.318.1.1.17.6.2 | ScalarxATSInputContactTableSize | read-only | mandatory | The number of input contact entries. |
| 1.3.6.1.4.1.318.1.1.17.6.3 | TablexATSInputContactTable | not-accessible | mandatory | A list of contacts supported by the ATS. The number of entries is contained in the xATSInputContactTableSize OID. |
| 1.3.6.1.4.1.318.1.1.17.6.3.1 | RowxATSInputContactEntry | not-accessible | mandatory | A contact entry containing information for a given contact. |
| 1.3.6.1.4.1.318.1.1.17.6.3.1.1 | ColumnxATSInputContactNumber | read-only | mandatory | An index identifying the contact on the ATS. |
| 1.3.6.1.4.1.318.1.1.17.6.3.1.2 | ColumnxATSInputContactName | read-write | mandatory | The description of the purpose/use of the contact. |
| 1.3.6.1.4.1.318.1.1.17.6.3.1.3 | ColumnxATSInputContactNormalState | read-write | mandatory | The normal operating position of the contact. |
| 1.3.6.1.4.1.318.1.1.17.6.3.1.4 | ColumnxATSInputContactCurrentState | read-only | mandatory | This value indicates the current state of the contact. |
| 1.3.6.1.4.1.318.1.1.17.7 | NodexATSOutputRelays | |||
| 1.3.6.1.4.1.318.1.1.17.7.1 | ScalarxATSOutputRelayNumRelays | read-only | mandatory | The number of output relays supported by the ATS. |
| 1.3.6.1.4.1.318.1.1.17.7.2 | ScalarxATSOutputRelayTableSize | read-only | mandatory | The number of output relay entries. |
| 1.3.6.1.4.1.318.1.1.17.7.3 | TablexATSOutputRelayTable | not-accessible | mandatory | A list of output relays supported by the ATS. The number of entries is contained in the xATSOutputRelayTableSize OID. |
| 1.3.6.1.4.1.318.1.1.17.7.3.1 | RowxATSOutputRelayEntry | not-accessible | mandatory | A output relay entry containing information for a given contact. |
| 1.3.6.1.4.1.318.1.1.17.7.3.1.1 | ColumnxATSOutputRelayNumber | read-only | mandatory | An index identifying the output relay on the ATS. |
| 1.3.6.1.4.1.318.1.1.17.7.3.1.2 | ColumnxATSOutputRelayName | read-write | mandatory | The description of the purpose/use of the output relay. |
| 1.3.6.1.4.1.318.1.1.17.7.3.1.3 | ColumnxATSOutputRelayNormalState | read-write | mandatory | The normal operating position of the output relay. |
| 1.3.6.1.4.1.318.1.1.17.7.3.1.4 | ColumnxATSOutputRelayCurrentState | read-only | mandatory | This value indicates the current state of the output relay. |
| 1.3.6.1.4.1.318.1.1.17.8 | NodexATSMisc | |||
| 1.3.6.1.4.1.318.1.1.18 | Nodegenerator | |||
| 1.3.6.1.4.1.318.1.1.18.1 | NodexATSGenerator | |||
| 1.3.6.1.4.1.318.1.1.18.1.1 | NodexATSGeneratorIdent | |||
| 1.3.6.1.4.1.318.1.1.18.1.1.1 | ScalarxATSGeneratorIdentModelNumber | read-only | mandatory | A character string identifying the model number of the generator. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.18.1.1.2 | ScalarxATSGeneratorIdentSerialNumber | read-only | mandatory | A character string identifying the serial number of the generator. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.18.1.1.3 | ScalarxATSGeneratorIdentDateofManufacture | read-only | mandatory | A character string identifying when the generator was manufactured in mm/dd/yyyy format. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.18.1.1.4 | ScalarxATSGeneratorIdentVoltageConfiguration | read-only | mandatory | The voltage for which the generator's alternator is designed. Specified in Volts line-to-line. |
| 1.3.6.1.4.1.318.1.1.18.1.1.5 | ScalarxATSGeneratorIdentMaxPowerRating | read-only | mandatory | The max power rating of the generator. Specified in kW. |
| 1.3.6.1.4.1.318.1.1.18.1.1.6 | ScalarxATSGeneratorIdentAlternatorFrequency | read-only | mandatory | The frequency for which the generator's alternator is designed. Specified in Hertz. |
| 1.3.6.1.4.1.318.1.1.18.1.2 | NodexATSGeneratorStatus | |||
| 1.3.6.1.4.1.318.1.1.18.1.2.1 | ScalarxATSGeneratorStatusGeneratorName | read-write | mandatory | The name or label for the generator connected to the source 2 of the ATS. |
| 1.3.6.1.4.1.318.1.1.18.1.2.2 | ScalarxATSGeneratorStatusOperational | read-only | mandatory | The operational status of the generator. unavailable when unrecognized status is received. |
| 1.3.6.1.4.1.318.1.1.18.1.2.3 | ScalarxATSGeneratorStatusModeSwitchPosition | read-only | mandatory | The position of the generator's auto-mode switch. In automatic mode, the generator is started and stopped via the remote start contact, which has state indicat… |
| 1.3.6.1.4.1.318.1.1.18.1.2.4 | ScalarxATSGeneratorStatusRemoteStart | read-only | mandatory | The status of the generator's remote start contact, which is provided as an output from the transfer switch to start/stop the generator when in automatic mode. |
| 1.3.6.1.4.1.318.1.1.18.1.3 | NodexATSGeneratorAdvStatus | |||
| 1.3.6.1.4.1.318.1.1.18.1.3.1 | ScalarxATSGeneratorAdvStatusBatteryVoltage | read-only | mandatory | The voltage of the generator's starting battery. Measured in tenths of VDC, or -1 if not available. |
| 1.3.6.1.4.1.318.1.1.18.1.3.2 | ScalarxATSGeneratorAdvStatusOilPressure | read-only | mandatory | The generator's engine oil pressure. Measured in tenths of Psi or kPa, based on the value of the xATSGeneratorSettingsMetricUnit OID, or -1 if not available. |
| 1.3.6.1.4.1.318.1.1.18.1.3.3 | ScalarxATSGeneratorAdvStatusCoolantTemperature | read-only | mandatory | Current coolant temperature in the generator. Measured in degrees Celsius or Fahrenheit, based on the value of the xATSGeneratorSettingsMetricUnit OID, or -1 i… |
| 1.3.6.1.4.1.318.1.1.18.1.3.4 | ScalarxATSGeneratorAdvStatusEngineRPM | read-only | mandatory | Current engine speed of the generator. Measured in RPM, or -1 if not available. |
| 1.3.6.1.4.1.318.1.1.18.1.3.5 | ScalarxATSGeneratorAdvStatusOilLevel | read-only | mandatory | Indicates adequate oil level in the generator. |
| 1.3.6.1.4.1.318.1.1.18.1.3.6 | ScalarxATSGeneratorAdvStatusCoolantLevel | read-only | mandatory | Indicates adequate coolant level in the generator. |
| 1.3.6.1.4.1.318.1.1.18.1.4 | NodexATSGeneratorOutput | |||
| 1.3.6.1.4.1.318.1.1.18.1.4.1 | ScalarxATSGeneratorOutputFrequency | read-only | mandatory | The output frequency of the generator. Measured in tenths of Hertz, or -1 if not available. |
| 1.3.6.1.4.1.318.1.1.18.1.4.2 | ScalarxATSGeneratorOutputTotalPower | read-only | mandatory | The total output power of the generator. Measured in tenths of tenths of kW, or -1 if not available. |
| 1.3.6.1.4.1.318.1.1.18.1.4.3 | ScalarxATSGeneratorOutputTotalApparentPower | read-only | mandatory | The total output power of the generator. Measured in tenths of kVA, or -1 if not available. |
| 1.3.6.1.4.1.318.1.1.18.1.4.4 | ScalarxATSGeneratorOutputTotalPowerFactor | read-only | mandatory | Indicates the total load power factor of the generator. A value of 100 representing a unity power factor (1.00), or -1 when if not available. |
| 1.3.6.1.4.1.318.1.1.18.1.4.5 | ScalarxATSGeneratorOutputTableSize | read-only | mandatory | The number of generator output phase entries. |
| 1.3.6.1.4.1.318.1.1.18.1.4.6 | TablexATSGeneratorOutputPhaseTable | not-accessible | mandatory | A list of generator output table entries. The number of entries is contained in the xATSGeneratorOutputTableSize OID. |
| 1.3.6.1.4.1.318.1.1.18.1.4.6.1 | RowxATSGeneratorOutputPhaseEntry | not-accessible | mandatory | An entry containing information applicable to a particular generator output phase. |
| 1.3.6.1.4.1.318.1.1.18.1.4.6.1.1 | ColumnxATSGeneratorOutputPhaseIndex | read-only | mandatory | Description of each generator output phase utilized in this device. |
| 1.3.6.1.4.1.318.1.1.18.1.4.6.1.2 | ColumnxATSGeneratorOutputVoltageLtoL | read-only | mandatory | Line-to-line generator output voltage. Measured in Volts, or -1 if not available. |
| 1.3.6.1.4.1.318.1.1.18.1.4.6.1.3 | ColumnxATSGeneratorOutputVoltageLtoN | read-only | mandatory | Line-to-neutral generator output voltage. Measured in volts, or -1 if not available. |
| 1.3.6.1.4.1.318.1.1.18.1.4.6.1.4 | ColumnxATSGeneratorOutputPhaseCurrent | read-only | mandatory | Generator load current per phase. Measured in Amps, or -1 if not available. |
| 1.3.6.1.4.1.318.1.1.18.1.4.6.1.5 | ColumnxATSGeneratorOutputPower | read-only | mandatory | Generator output power per phase. Measured in tenths of kW, or -1 if not available. |
| 1.3.6.1.4.1.318.1.1.18.1.4.6.1.6 | ColumnxATSGeneratorOutputApparentPower | read-only | mandatory | Generator output power per phase. Measured in tenths of kVA, or -1 if not available. |
| 1.3.6.1.4.1.318.1.1.18.1.4.6.1.7 | ColumnxATSGeneratorOutputPowerFactor | read-only | mandatory | Indicates the load power factor of the generator output per phase. A value of 100 representing a unity power factor (1.00), or -1 if not available. |
| 1.3.6.1.4.1.318.1.1.18.1.5 | NodexATSGeneratorSettings | |||
| 1.3.6.1.4.1.318.1.1.18.1.5.1 | ScalarxATSGeneratorSettingsVoltageAdjust | read-only | mandatory | The voltage adjust of the generator. Specified in volts line-to-line, or -1 if not available. |
| 1.3.6.1.4.1.318.1.1.18.1.5.2 | ScalarxATSGeneratorSettingsFrequencyAdjust | read-only | mandatory | The frequency adjust of the generator. Specified in tenths of Hertz. |
| 1.3.6.1.4.1.318.1.1.18.1.5.3 | ScalarxATSGeneratorSettingsStartDelay | read-only | mandatory | The delay, in seconds, after the remote run signal is activated before the generator's engine will be cranked to start, or -1 if not available. |
| 1.3.6.1.4.1.318.1.1.18.1.5.4 | ScalarxATSGeneratorSettingsStopDelay | read-only | mandatory | The delay, in seconds, before the generator will stop after the remote run signal is deactivated, or -1 if not available. |
| 1.3.6.1.4.1.318.1.1.18.1.5.5 | ScalarxATSGeneratorSettingsCrankCycleEnable | read-only | mandatory | When Crank Cycle is enabled, the engine will be cranked up to the time specified by the xATSGeneratorSettingsCrankTime OID. If the generator's engine does not … |
| 1.3.6.1.4.1.318.1.1.18.1.5.6 | ScalarxATSGeneratorSettingsCrankTime | read-only | mandatory | The duration of engine cranking, in seconds, when starting the generator. Applicable when the xATSGeneratorSettingsCrankCycleEnable OID is enabled. -1 if not a… |
| 1.3.6.1.4.1.318.1.1.18.1.5.7 | ScalarxATSGeneratorSettingsCrankRestTime | read-only | mandatory | The pause duration, in seconds, following an unsuccessful attempt to start the generator. Applicable when the xATSGeneratorSettingsCrankCycleEnable OID is enab… |
| 1.3.6.1.4.1.318.1.1.18.1.5.8 | ScalarxATSGeneratorSettingsNumberCrank | read-only | mandatory | The number of failed crank attempts before giving up on starting the generator. Applicable when the xATSGeneratorSettingsCrankCycleEnable OID is enabled. -1 if… |
| 1.3.6.1.4.1.318.1.1.18.1.5.9 | ScalarxATSGeneratorSettingsMetricUnit | read-write | mandatory | Specifies the use of metric units in generator related OIDs, as well as on all other interfaces including the generator's local interface. |
| 1.3.6.1.4.1.318.1.1.18.1.6 | NodexATSGeneratorService | |||
| 1.3.6.1.4.1.318.1.1.18.1.6.1 | ScalarxATSGeneratorServiceTotalRunHoursLifetime | read-only | mandatory | Total time that the generator engine has been run, over the life of the generator. Measured in hours. -1 if not available. |
| 1.3.6.1.4.1.318.1.1.18.1.6.2 | ScalarxATSGeneratorServiceEngineStartsLifetime | read-only | mandatory | Number of engine starts over the life of the generator. -1 if not available. |
| 1.3.6.1.4.1.318.1.1.18.1.6.3 | ScalarxATSGeneratorServiceTotalkWhLifetime | read-only | mandatory | Total kWh of operation over the life of the generator. -1 if not available. |
| 1.3.6.1.4.1.318.1.1.18.1.6.4 | ScalarxATSGeneratorServiceTotalRunHoursSinceMaintenance | read-only | mandatory | Total time that the generator engine has been run, since last service maintenance. Measured in tenths of hours. -1 if not available. |
| 1.3.6.1.4.1.318.1.1.18.1.6.5 | ScalarxATSGeneratorServiceEngineStartsSinceMaintenance | read-only | mandatory | Number of engine starts since last service maintenance. -1 if not available. |
| 1.3.6.1.4.1.318.1.1.18.1.6.6 | ScalarxATSGeneratorServiceTotalkWhMaintenance | read-only | mandatory | Total kWh of operation since last service maintenance. -1 if not available. |
| 1.3.6.1.4.1.318.1.1.18.1.6.7 | ScalarxATSGeneratorServiceResetRecord | read-write | mandatory | Resets the engine start counter, engine run-hours, and kWh values that have accumulated in the generator since last maintenance. Also, the last service date wi… |
| 1.3.6.1.4.1.318.1.1.18.1.6.8 | ScalarxATSGeneratorServiceRecordResetDate | read-only | mandatory | Date at which the generator's service record was reset, in dd-mmm-yyyy format. |
| 1.3.6.1.4.1.318.1.1.18.1.6.9 | ScalarxATSGeneratorServiceNextServiceDate | read-only | mandatory | Date at which the next generator service is due in dd-mmm-yyyy format. Based on the xATSGeneratorServiceCalendarIntervalThreshold OID or '' if the calendar-bas… |
| 1.3.6.1.4.1.318.1.1.18.1.6.10 | ScalarxATSGeneratorServiceRunHoursUntilServiceDate | read-only | mandatory | Run hours until the next generator service is due, in hours. Based on the xATSGeneratorServiceRunHoursThreshold OID or -1 if the run hour-based threshold is se… |
| 1.3.6.1.4.1.318.1.1.18.1.6.11 | ScalarxATSGeneratorServiceRunHoursThreshold | read-write | mandatory | Run hour-based service interval. When the run-hours since service surpasses this threshold, generator service is due. |
| 1.3.6.1.4.1.318.1.1.18.1.6.12 | ScalarxATSGeneratorServiceCalendarIntervalThreshold | read-write | mandatory | Calendar-based service interval. When the next service date, as indicated by the xATSGeneratorServiceNextServiceDate OID is in the past, generator is due for s… |
| 1.3.6.1.4.1.318.1.1.18.1.7 | NodexATSGeneratorFuelSystem | |||
| 1.3.6.1.4.1.318.1.1.18.1.7.1 | ScalarxATSGeneratorFuelSystemType | read-only | mandatory | The type of fuel used by the generator. |
| 1.3.6.1.4.1.318.1.1.18.1.7.2 | ScalarxATSGeneratorFuelSystemTankSize | read-only | mandatory | Size of the generator's fuel tank. Specified in gallons or liters, based on the value of the xATSGeneratorSettingsMetricUnit OID, or -1 if not available. |
| 1.3.6.1.4.1.318.1.1.18.1.7.3 | ScalarxATSGeneratorFuelSystemFuelLevel | read-only | mandatory | Fuel remaining in the generator tank. Measured in percent of tank fill, or -1 if not available. |
| 1.3.6.1.4.1.318.1.1.18.1.7.4 | ScalarxATSGeneratorFuelSystemRuntimePower | read-only | mandatory | The power value used in the runtime remaining calculation. Measured in tenths of kW, or -1 if not available. |
| 1.3.6.1.4.1.318.1.1.18.1.7.5 | ScalarxATSGeneratorFuelSystemEstimatedRunTime | read-only | mandatory | An estimate of available runtime for the generator, based on available fuel as specified in the xATSGeneratorFuelSystemFuelLevel OID and kW load as specified i… |
| 1.3.6.1.4.1.318.1.1.18.1.7.6 | ScalarxATSGeneratorFuelSystemLowRunTimeThreshold | read-write | mandatory | Threshold below which a low runtime alarm will exist. |
| 1.3.6.1.4.1.318.1.1.18.1.7.7 | ScalarxATSGeneratorFuelSystemVeryLowRunTimeThreshold | read-write | mandatory | Threshold below which a very low runtime alarm will exist. |
| 1.3.6.1.4.1.318.1.1.18.1.7.8 | ScalarxATSGeneratorFuelSystemLowFuelLevelThreshold | read-write | mandatory | Threshold below which a low fuel alarm will exist, with a value of 0 indicating disabled. Specified as percent of tank fill. |
| 1.3.6.1.4.1.318.1.1.18.1.7.9 | ScalarxATSGeneratorFuelSystemVeryLowFuelLevelThreshold | read-write | mandatory | Threshold below which a very low fuel alarm will exist, with a value of 0 indicating disabled. Specified as percent of tank fill. |
| 1.3.6.1.4.1.318.1.1.19 | NodeconsolePortServer | |||
| 1.3.6.1.4.1.318.1.1.19.1 | NodecpsAP930x | |||
| 1.3.6.1.4.1.318.1.1.19.1.1 | NodecpsAP930xSys | |||
| 1.3.6.1.4.1.318.1.1.19.1.1.1 | ScalarapCPSpname | read-only | mandatory | The product's name. |
| 1.3.6.1.4.1.318.1.1.19.1.1.2 | ScalarapCPSversion | read-only | mandatory | The firmware's version. |
| 1.3.6.1.4.1.318.1.1.19.1.1.3 | NodeapCPSPower | |||
| 1.3.6.1.4.1.318.1.1.19.1.1.3.1 | ScalarapCPSPwNum | read-only | mandatory | The number of the power supplies. |
| 1.3.6.1.4.1.318.1.1.19.1.1.3.2 | ScalarapCPSPw1 | read-only | mandatory | State of the first power supply. 0 will indicate not installed, 1 will indicate power ON, 2 will indicate power OFF. |
| 1.3.6.1.4.1.318.1.1.19.1.1.3.3 | ScalarapCPSPw2 | read-only | mandatory | State of the second power supply. 0 will indicate not installed, 1 will indicate power ON, 2 will indicate power OFF. |
| 1.3.6.1.4.1.318.1.1.19.1.1.4 | NodeapCPSPcmcia | |||
| 1.3.6.1.4.1.318.1.1.19.1.1.4.1 | ScalarapCPSNPcmcia | read-only | mandatory | Number of PCMCIA cards available. |
| 1.3.6.1.4.1.318.1.1.19.1.1.4.2 | TablecpsCardIdentTable | not-accessible | mandatory | A table of PCMCIA card identifications. |
| 1.3.6.1.4.1.318.1.1.19.1.1.4.2.1 | RowcpsCardIdentEntry | not-accessible | mandatory | Identification information for a PCMCIA card. |
| 1.3.6.1.4.1.318.1.1.19.1.1.4.2.1.1 | ColumncpsCardIdentIndex | read-only | mandatory | Number to identify the socket Card. |
| 1.3.6.1.4.1.318.1.1.19.1.1.4.2.1.2 | ColumncpsCardIdentProd | read-only | mandatory | Product identification string. |
| 1.3.6.1.4.1.318.1.1.19.1.1.4.2.1.3 | ColumncpsCardIdentMan | read-only | mandatory | Manufacturer ID code. |
| 1.3.6.1.4.1.318.1.1.19.1.1.4.2.1.4 | ColumncpsCardIdentFunc | read-only | mandatory | Function ID code. |
| 1.3.6.1.4.1.318.1.1.19.1.1.4.2.1.5 | ColumncpsCardIdentPCI | read-only | mandatory | PCI ID |
| 1.3.6.1.4.1.318.1.1.19.1.1.4.3 | TablecpsCardConfTable | not-accessible | mandatory | A table of socket configuration information. |
| 1.3.6.1.4.1.318.1.1.19.1.1.4.3.1 | RowcpsCardConfEntry | not-accessible | mandatory | Configuration information for a socket. |
| 1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.1 | ColumncpsCardConfIndex | read-only | mandatory | Number to identify the socket PCMCIA. |
| 1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.2 | ColumncpsCardConfPower | read-only | mandatory | Power Settings. |
| 1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.3 | ColumncpsCardConfType | read-only | mandatory | Interface Type. |
| 1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.4 | ColumncpsCardConfInter | read-only | mandatory | Interrupt number. |
| 1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.5 | ColumncpsCardConfFunc | read-only | mandatory | Function. |
| 1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.6 | ColumncpsCardConfCardv | read-only | mandatory | Card values. |
| 1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.7 | ColumncpsCardConfPort1 | read-only | mandatory | I/O Port 1. |
| 1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.8 | ColumncpsCardConfPort2 | read-only | mandatory | I/O Port 2. |
| 1.3.6.1.4.1.318.1.1.19.1.1.4.4 | TablecpsCardStatusTable | not-accessible | mandatory | A table of current socket status information. |
| 1.3.6.1.4.1.318.1.1.19.1.1.4.4.1 | RowcpsCardStatusEntry | not-accessible | mandatory | Current status information for a socket. |
| 1.3.6.1.4.1.318.1.1.19.1.1.4.4.1.1 | ColumncpsCardStatusIndex | read-only | mandatory | Number to identify the socket PCMCIA. |
| 1.3.6.1.4.1.318.1.1.19.1.1.4.4.1.2 | ColumncpsCardStatusCard | read-only | mandatory | Current Card State. |
| 1.3.6.1.4.1.318.1.1.19.1.1.4.4.1.3 | ColumncpsCardStatusFunc | read-only | mandatory | Current Function. |
| 1.3.6.1.4.1.318.1.1.19.1.1.5 | ScalarapCPSFlashSize | read-only | mandatory | Total amount of flash memory in Mbytes. |
| 1.3.6.1.4.1.318.1.1.19.1.1.6 | ScalarapCPSRAMSize | read-only | mandatory | Total amount of RAM in Mbytes. |
| 1.3.6.1.4.1.318.1.1.19.1.1.7 | ScalarapCPSCPUfreq | read-only | mandatory | CPU clock in MHz. |
| 1.3.6.1.4.1.318.1.1.19.1.1.8 | ScalarapCPSDevId | read-only | mandatory | The product's identifier. |
| 1.3.6.1.4.1.318.1.1.19.1.2 | NodecpsAP930xConf | |||
| 1.3.6.1.4.1.318.1.1.19.1.2.1 | ScalarcpsHostName | read-write | mandatory | The Host Name. |
| 1.3.6.1.4.1.318.1.1.19.1.2.2 | ScalarcpsConsoleBanner | read-write | mandatory | The console banner. |
| 1.3.6.1.4.1.318.1.1.19.1.2.3 | ScalarcpsMotd | read-write | mandatory | The motd message. |
| 1.3.6.1.4.1.318.1.1.19.1.2.4 | NodecpsEthItf | |||
| 1.3.6.1.4.1.318.1.1.19.1.2.4.1 | ScalarcpsEthDhcpc | read-write | mandatory | 0 will indicate DHCP inactive, 1 will indicate DHCP active, 2 will indicate DHCP active and the last parameter is saved. |
| 1.3.6.1.4.1.318.1.1.19.1.2.4.2 | ScalarcpsEthIPaddr | read-write | mandatory | This is the IP address of the Ethernet Interface. |
| 1.3.6.1.4.1.318.1.1.19.1.2.4.3 | ScalarcpsEthIPmask | read-write | mandatory | The mask for the Ethernet network. |
| 1.3.6.1.4.1.318.1.1.19.1.2.4.4 | ScalarcpsEthMTU | read-write | mandatory | The Maximum Transmission Unit size, which determines whether packets should be broken up. |
| 1.3.6.1.4.1.318.1.1.19.1.2.4.5 | ScalarcpsEthIPaddr2 | read-write | mandatory | The Ethernet secondary IP address. |
| 1.3.6.1.4.1.318.1.1.19.1.2.4.6 | ScalarcpsEthIPmask2 | read-write | mandatory | The Ethernet secondary IP mask. |
| 1.3.6.1.4.1.318.1.1.19.1.2.5 | NodecpsNameService | |||
| 1.3.6.1.4.1.318.1.1.19.1.2.5.1 | ScalarcpsResolverOrder | read-write | mandatory | Specifies how host lookups are to be performed. Valid values : empty, 'hosts', 'bind', 'hosts, bind', 'bind, hosts' |
| 1.3.6.1.4.1.318.1.1.19.1.2.5.2 | ScalarcpsMultipleIP | read-write | mandatory | Valid values are ON or OFF. If set to ON, the resolve library will return all valid addresses for a host that appears in the /etc/hosts file, instead of only t… |
| 1.3.6.1.4.1.318.1.1.19.1.2.5.3 | NodecpsDNSserv | |||
| 1.3.6.1.4.1.318.1.1.19.1.2.5.3.1 | ScalarcpsDNSpriserv | read-write | mandatory | Internet Address (in dot notation) of primary name server that the resolver should query. |
| 1.3.6.1.4.1.318.1.1.19.1.2.5.3.2 | ScalarcpsDNSsecserv | read-write | mandatory | Internet Address (in dot notation) of secondary name server that the resolver should query. |
| 1.3.6.1.4.1.318.1.1.19.1.2.5.3.3 | ScalarcpsDNSdomain | read-write | mandatory | Local domain name. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6 | NodecpsSerialPortConf | |||
| 1.3.6.1.4.1.318.1.1.19.1.2.6.1 | NodecpsSerialGlobal | |||
| 1.3.6.1.4.1.318.1.1.19.1.2.6.1.1 | ScalarcpsSerialInclude | read-write | mandatory | File used in centralized management. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.1.2 | ScalarcpsSerialNFS | read-write | mandatory | Remote Network File System where data buffering will be written instead of the default directory '/var/run/DB'. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.1.3 | ScalarcpsSerialLockDir | read-write | mandatory | The lock directory. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.1.4 | ScalarcpsSerialRlogin | read-write | mandatory | Location of the rlogin binary that accepts the -i flag. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.1.5 | ScalarcpsSerialPppd | read-write | mandatory | Location of the pppd binary. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.1.6 | ScalarcpsSerialTelnet | read-write | mandatory | Location of the telnet application. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.1.7 | ScalarcpsSerialSsh | read-write | mandatory | Location of the ssh application. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.1.8 | ScalarcpsSerialLocalLogins | read-write | mandatory | This parameter is only necessary when authentication is being performed for a port. This is useful if the Radius authentication server is down. 0 indicates OFF… |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.1.9 | ScalarcpsSerialFacility | read-write | mandatory | This value (0-7) is the Local facility sent to the syslog daemon. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.1.10 | ScalarcpsSerialDBFacility | read-write | mandatory | This value (0-7) is the Local facility sent to the syslog daemon. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.1.11 | TablecpsSerialGroupTable | not-accessible | mandatory | |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.1.11.1 | RowcpsSerialGroupEntry | not-accessible | mandatory | |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.1.11.1.1 | ColumncpsSerialGroupIndex | read-only | mandatory | Number to identify the group. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.1.11.1.2 | ColumncpsSerialGroupName | read-write | mandatory | The group name. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.1.11.1.3 | ColumncpsSerialGroupUsers | read-write | mandatory | The user's names. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2 | NodecpsSerialSpec | |||
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1 | TablecpsSerialPortTable | not-accessible | mandatory | This is the specific configuration per serial port. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1 | RowcpsSerialPortEntry | not-accessible | mandatory | One particular serial port configuration. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.1 | ColumncpsSerialPortNumber | read-only | mandatory | Number to identify the serial port. Value 0 is ALL. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.2 | ColumncpsSerialPortTty | read-write | mandatory | The device name for the serial port. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.3 | ColumncpsSerialPortName | read-write | mandatory | Alias name given to the server connected to the serial port. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.4 | ColumncpsSerialPortSpeed | read-write | mandatory | The speed of the serial port. Supported values are: 50, 75, 110, 134, 150, 200, 300, 600, 1200, 1800, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 1152… |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.5 | ColumncpsSerialPortDataSize | read-write | mandatory | The data size for the serial port. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.6 | ColumncpsSerialPortStopBits | read-write | mandatory | The number of stop bits for the serial port. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.7 | ColumncpsSerialPortParity | read-write | mandatory | The parity for the serial port. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.8 | ColumncpsSerialPortFlowCtrl | read-write | mandatory | The flow control for the serial port. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.9 | ColumncpsSerialPortDTRdelay | read-write | mandatory | This specifies how long (in milliseconds) a DTR signal will be turned off before it is turned on again. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.10 | ColumncpsSerialPortDCDCtrl | read-write | mandatory | DCD signal controls the connection request. 0 will indicate nocontrol, 1 will indicate control. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.11 | ColumncpsSerialPortLogUtmp | read-write | mandatory | Update the login records in /var/run/utmp file. 0 will indicate inactive, 1 will indicate active. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.12 | ColumncpsSerialPortLogWtmp | read-write | mandatory | Update the login records in /var/run/wtmp file. 0 will indicate inactive, 1 will indicate active. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.13 | ColumncpsSerialPortLogform | read-write | mandatory | This is the format to write the login record. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.14 | ColumncpsSerialPortAuthtype | read-write | mandatory | Authentication type. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.15 | ColumncpsSerialPortAuthSrv1 | read-write | mandatory | IP address of the primary authentication server. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.16 | ColumncpsSerialPortAccSrv1 | read-write | mandatory | IP address of the primary accounting server. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.17 | ColumncpsSerialPortAuthTmo | read-write | mandatory | This is the timeout (in seconds) for the authentication query to be answered. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.18 | ColumncpsSerialPortAuthRetr | read-write | mandatory | This defines the number of times each server is tried before another is contacted. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.19 | ColumncpsSerialPortAuthSrv2 | read-write | mandatory | IP address of the secondary authentication server. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.20 | ColumncpsSerialPortAccSrv2 | read-write | mandatory | IP address of the secondary accounting server. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.21 | ColumncpsSerialPortAuthSecret | read-write | mandatory | This is the shared secret with authentication servers. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.22 | ColumncpsSerialPortAuthRadP | read-write | mandatory | Radius state. 0 will indicate inactive, 1 will indicate active. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.23 | ColumncpsSerialPortAuthAcc | read-write | mandatory | Access restriction. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.24 | ColumncpsSerialPortProtocol | read-write | mandatory | Defines the serial port's protocol. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.25 | ColumncpsSerialPortRemoteIP | read-write | mandatory | This is the default IP address of the serial port. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.26 | ColumncpsSerialPortSocketPort | read-write | mandatory | This defines an alternative labeling system for the serial port. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.27 | ColumncpsSerialPortRemHost | read-write | mandatory | The IP address of the host to which the serial port will connect. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.28 | ColumncpsSerialPortBanner | read-write | mandatory | This defines the banner. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.29 | ColumncpsSerialPortPrompt | read-write | mandatory | This defines the login prompt to the serial port. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.30 | ColumncpsSerialPortTermType | read-write | mandatory | This defines the terminal type. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.31 | ColumncpsSerialPortAutomUsr | read-write | mandatory | This defines the automatic user. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.32 | ColumncpsSerialPortNetMask | read-write | mandatory | The network mask used in dial in connection. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.33 | ColumncpsSerialPortPppMtu | read-write | mandatory | The PPP MTU - dial in connection. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.34 | ColumncpsSerialPortPppMru | read-write | mandatory | The PPP MRU - dial in connection. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.35 | ColumncpsSerialPortPppOptions | read-write | mandatory | The PPP options when the PPP session is autodetected. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.36 | ColumncpsSerialPortPppFoption | read-write | mandatory | The PPP forced options when the user has already been authenticated. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.37 | ColumncpsSerialPortModemChat | read-write | mandatory | The initchat send to modem connected. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.38 | ColumncpsSerialPortSttyCmd | read-write | mandatory | The tty settings after socket connection is established. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.39 | ColumncpsSerialPortSockTx | read-write | mandatory | Defines the delay (in milliseconds) before transmission to the Ethernet of data received through a serial port. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.40 | ColumncpsSerialPortSockPoll | read-write | mandatory | Keep-alive timer (milliseconds) for the TCP connection. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.41 | ColumncpsSerialPortSockIdle | read-write | mandatory | The idle timeout in seconds. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.42 | ColumncpsSerialPortDBsize | read-write | mandatory | Maximum size of the data buffering file. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.43 | ColumncpsSerialPortDBtime | read-write | mandatory | Timestamp in data buffering. 0 will indicate inactive, 1 will indicate active. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.44 | ColumncpsSerialPortDBmode | read-write | mandatory | Data buffering mode : circ or line. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.45 | ColumncpsSerialPortDBsyslog | read-write | mandatory | Size of the data buffer sent to syslog. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.46 | ColumncpsSerialPortDBmenu | read-write | mandatory | Menu type for data buffering. 0 will indicate display Menu, 1 will indicate inactive, 2 will indicate DB, 3 will indicate Parc. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.47 | ColumncpsSerialPortDBalarm | read-write | mandatory | Alarm generation status. 0 will indicate inactive, 1 will indicate active. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.48 | ColumncpsSerialPortSSHbreak | read-write | mandatory | Break sequence - ssh session. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.49 | ColumncpsSerialPortSniffSess | read-write | mandatory | Sniff session type. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.50 | ColumncpsSerialPortSniffAdm | read-write | mandatory | List of admin users allowed to sniff session. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.51 | ColumncpsSerialPortSniffEsc | read-write | mandatory | Escape sequence used in sniff session. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.52 | ColumncpsSerialPortSniffMsess | read-write | mandatory | |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.53 | ColumncpsSerialPortTelnetMode | read-write | mandatory | Mode negotiated by client telnet with the server. 0 will indicate text, 1 will indicate binary. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.54 | ColumncpsSerialPortSysBufSess | read-write | mandatory | Syslog Buffering at all times. 0 will indicate yes, 1 will indicate no. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.55 | ColumncpsSerialPortLFSuppress | read-write | mandatory | LF suppression in socket_server session. 0 will indicate inactive, 1 will indicate active. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.56 | ColumncpsSerialPortAutoInput | read-write | mandatory | Input string used for auto answer. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.57 | ColumncpsSerialPortAutoOutput | read-write | mandatory | Output string used for auto answer. |
| 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.58 | ColumncpsSerialPortBreakInterval | read-write | mandatory | The break interval in milliseconds. |
| 1.3.6.1.4.1.318.1.1.19.1.3 | NodecpsAP930xInfo | |||
| 1.3.6.1.4.1.318.1.1.19.1.3.1 | TablecpsInfoSerialPortTable | not-accessible | mandatory | This is the information of the specific serial port. |
| 1.3.6.1.4.1.318.1.1.19.1.3.1.1 | RowcpsInfoSerialPortEntry | not-accessible | mandatory | One particular serial port. |
| 1.3.6.1.4.1.318.1.1.19.1.3.1.1.1 | ColumncpsInfoSerialPortNumber | read-only | mandatory | Number to identify the serial port. |
| 1.3.6.1.4.1.318.1.1.19.1.3.1.1.2 | ColumncpsInfoSerialPortTty | read-only | mandatory | The device name for the serial port. |
| 1.3.6.1.4.1.318.1.1.19.1.3.1.1.3 | ColumncpsInfoSerialPortName | read-only | mandatory | Alias name given to the server connected to the serial port. |
| 1.3.6.1.4.1.318.1.1.19.1.3.1.1.4 | ColumncpsInfoSerialPortSpeed | read-only | mandatory | The speed for serial port. |
| 1.3.6.1.4.1.318.1.1.19.1.3.1.1.5 | ColumncpsInfoSerialPortTxBytes | read-only | mandatory | The number of transmitted bytes by the serial port. |
| 1.3.6.1.4.1.318.1.1.19.1.3.1.1.6 | ColumncpsInfoSerialPortRXBytes | read-only | mandatory | The number of received bytes by the serial port. |
| 1.3.6.1.4.1.318.1.1.19.1.3.1.1.7 | ColumncpsInfoSerialPortErrFrame | read-only | mandatory | The number of frame errors. |
| 1.3.6.1.4.1.318.1.1.19.1.3.1.1.8 | ColumncpsInfoSerialPortErrParity | read-only | mandatory | The number of parity errors. |
| 1.3.6.1.4.1.318.1.1.19.1.3.1.1.9 | ColumncpsInfoSerialPortErrBreaks | read-only | mandatory | The number of breaks errors. |
| 1.3.6.1.4.1.318.1.1.19.1.3.1.1.10 | ColumncpsInfoSerialPortErrOverrun | read-only | mandatory | The number of overrun errors. |
| 1.3.6.1.4.1.318.1.1.19.1.3.1.1.11 | ColumncpsInfoSerialPortSigDTR | read-only | mandatory | The state of the DTR signal. 0 will indicate down, 1 will indicate up. |
| 1.3.6.1.4.1.318.1.1.19.1.3.1.1.12 | ColumncpsInfoSerialPortSigCD | read-only | mandatory | The state of the DCD signal. 0 will indicate down, 1 will indicate up. |
| 1.3.6.1.4.1.318.1.1.19.1.3.1.1.13 | ColumncpsInfoSerialPortSigDSR | read-only | mandatory | The state of the DSR signal. 0 will indicate down, 1 will indicate up. |
| 1.3.6.1.4.1.318.1.1.19.1.3.1.1.14 | ColumncpsInfoSerialPortSigRTS | read-only | mandatory | The state of the RTS signal. 0 will indicate down, 1 will indicate up. |
| 1.3.6.1.4.1.318.1.1.19.1.3.1.1.15 | ColumncpsInfoSerialPortSigCTS | read-only | mandatory | The state of the CTS signal. 0 will indicate down, 1 will indicate up. |
| 1.3.6.1.4.1.318.1.1.19.1.3.1.1.16 | ColumncpsInfoSerialPortSigRI | read-only | mandatory | The state of the RI signal. 0 will indicate down, 1 will indicate up. |
| 1.3.6.1.4.1.318.1.1.19.1.4 | NodecpsAP930xAdm | |||
| 1.3.6.1.4.1.318.1.1.19.1.4.1 | ScalarapCPSSave | read-write | mandatory | Exec saveconf command. 0 will indicate don't save, 1 will indicate save. |
| 1.3.6.1.4.1.318.1.1.19.1.4.2 | ScalarapCPSSerialHUP | read-write | mandatory | Exec signal_ras hup command. 0 will indicate no restart, 1 will indicate restart. |
| 1.3.6.1.4.1.318.1.1.20 | NodeaccessControl | |||
| 1.3.6.1.4.1.318.1.1.20.1 | NodeaccessPX | |||
| 1.3.6.1.4.1.318.1.1.20.1.1 | NodeaccessPXIdent | |||
| 1.3.6.1.4.1.318.1.1.20.1.1.1 | ScalaraccessPXIdentAlarmStatus | read-only | mandatory | Access PX alarm status 1 = Normal 2 = Warning 3 = Critical. |
| 1.3.6.1.4.1.318.1.1.20.1.1.2 | ScalaraccessPXIdentProductNumber | read-only | mandatory | The product number of the Access PX. |
| 1.3.6.1.4.1.318.1.1.20.1.1.3 | ScalaraccessPXIdentHardwareRev | read-only | mandatory | The hardware revision number of the Access PX. |
| 1.3.6.1.4.1.318.1.1.20.1.1.4 | ScalaraccessPXIdentDateOfManufacture | read-only | mandatory | The date of manufacture of the Access PX. |
| 1.3.6.1.4.1.318.1.1.20.1.1.5 | ScalaraccessPXIdentSerialNumber | read-only | mandatory | The serial number of the Access PX. |
| 1.3.6.1.4.1.318.1.1.20.1.2 | NodeaccessPXConfig | |||
| 1.3.6.1.4.1.318.1.1.20.1.2.1 | ScalaraccessPXConfigCardReaderEnableDisableAction | read-write | mandatory | Action to disable/enable the card reader. |
| 1.3.6.1.4.1.318.1.1.20.1.2.2 | ScalaraccessPXConfigAutoRelockTime | read-write | mandatory | Time (10 - 60) in seconds when the door will automatically relock after it has been unlocked and the handle has not been opened. |
| 1.3.6.1.4.1.318.1.1.20.1.2.3 | ScalaraccessPXConfigCardFormat | read-write | mandatory | Indicates and controls the various card format. |
| 1.3.6.1.4.1.318.1.1.20.1.3 | NodeaccessPXConfigFront | |||
| 1.3.6.1.4.1.318.1.1.20.1.3.1 | ScalaraccessPXConfigFrontDoorLockControl | read-write | mandatory | Control action (unlock, lock) for the front door. Setting this OID will unlock or lock the front door. Getting this OID will respond with the current state of … |
| 1.3.6.1.4.1.318.1.1.20.1.3.2 | ScalaraccessPXConfigFrontDoorMaxOpenTime | read-write | mandatory | Time in minutes, (1 - 120), that the front door can be allowed to remain open without generating an alarm condition. |
| 1.3.6.1.4.1.318.1.1.20.1.4 | NodeaccessPXStatusFront | |||
| 1.3.6.1.4.1.318.1.1.20.1.4.1 | ScalaraccessPXStatusFrontDoorLock | read-only | mandatory | Present state of the front door lock: unlocked, locked, not installed, or disconnected. |
| 1.3.6.1.4.1.318.1.1.20.1.4.2 | ScalaraccessPXStatusFrontDoor | read-only | mandatory | Present state of the front door: open, closed, not installed, or disconnected. |
| 1.3.6.1.4.1.318.1.1.20.1.4.3 | ScalaraccessPXStatusFrontDoorHandle | read-only | mandatory | Present state of the front door handle: open, closed, not installed, or disconnected. |
| 1.3.6.1.4.1.318.1.1.20.1.4.4 | ScalaraccessPXStatusFrontDoorMaxOpenTime | read-only | mandatory | Time in minutes, (1 - 120), that the front door can be allowed to remain open without generating an alarm condition. |
| 1.3.6.1.4.1.318.1.1.20.1.4.5 | ScalaraccessPXStatusFrontDoorAlarmStatus | read-only | mandatory | Front door alarm status 1 = Normal 2 = Warning 3 = Critical 4 = Front door not installed. |
| 1.3.6.1.4.1.318.1.1.20.1.5 | NodeaccessPXConfigRear | |||
| 1.3.6.1.4.1.318.1.1.20.1.5.1 | ScalaraccessPXConfigRearDoorLockControl | read-write | mandatory | Control action (unlock, lock) for the rear door. Setting this OID will unlock or lock the rear door. Getting this OID will respond with the current state of th… |
| 1.3.6.1.4.1.318.1.1.20.1.5.2 | ScalaraccessPXConfigRearDoorMaxOpenTime | read-write | mandatory | Time in minutes, (1 - 120), that the rear door can be allowed to remain open without generating an alarm condition. |
| 1.3.6.1.4.1.318.1.1.20.1.6 | NodeaccessPXStatusRear | |||
| 1.3.6.1.4.1.318.1.1.20.1.6.1 | ScalaraccessPXStatusRearDoorLock | read-only | mandatory | Present state of the rear door lock: unlocked, locked, not installed, or disconnected. |
| 1.3.6.1.4.1.318.1.1.20.1.6.2 | ScalaraccessPXStatusRearDoor | read-only | mandatory | Present state of the rear door: open, closed, not installed, or disconnected. |
| 1.3.6.1.4.1.318.1.1.20.1.6.3 | ScalaraccessPXStatusRearDoorHandle | read-only | mandatory | Present state of the rear door handle: open, closed, not installed, or disconnected. |
| 1.3.6.1.4.1.318.1.1.20.1.6.4 | ScalaraccessPXStatusRearDoorMaxOpenTime | read-only | mandatory | Time in minutes, (1 - 120), that the rear door can be allowed to remain open without generating an alarm condition. |
| 1.3.6.1.4.1.318.1.1.20.1.6.5 | ScalaraccessPXStatusRearDoorAlarmStatus | read-only | mandatory | Rear door alarm status 1 = Normal 2 = Warning 3 = Critical 4 = Rear door not installed. |
| 1.3.6.1.4.1.318.1.1.20.1.7 | NodeaccessPXConfigBeacon | |||
| 1.3.6.1.4.1.318.1.1.20.1.7.1 | ScalaraccessPXConfigBeaconName | read-write | mandatory | A descriptive name for the Beacon. |
| 1.3.6.1.4.1.318.1.1.20.1.7.2 | ScalaraccessPXConfigBeaconLocation | read-write | mandatory | A descriptive name for the location of the Beacon. |
| 1.3.6.1.4.1.318.1.1.20.1.7.3 | ScalaraccessPXConfigBeaconAction | read-write | mandatory | Control action (turnOff, turnOn) for the beacon. Setting this OID will turn the beacon off or on. Getting this OID will respond with the current state which co… |
| 1.3.6.1.4.1.318.1.1.20.1.8 | NodeaccessPXStatusBeacon | |||
| 1.3.6.1.4.1.318.1.1.20.1.8.1 | ScalaraccessPXStatusBeaconName | read-only | mandatory | The name of the beacon. |
| 1.3.6.1.4.1.318.1.1.20.1.8.2 | ScalaraccessPXStatusBeaconLocation | read-only | mandatory | The name of the location of the beacon. |
| 1.3.6.1.4.1.318.1.1.20.1.8.3 | ScalaraccessPXStatusBeaconCurrentState | read-only | mandatory | The current state of the beacon: off, on, not installed, or disconnected. |
| 1.3.6.1.4.1.318.1.1.21 | NodeapcLocalDisplay | |||
| 1.3.6.1.4.1.318.1.1.21.1 | NodeapcLocalDisplayIdent | |||
| 1.3.6.1.4.1.318.1.1.21.1.1 | ScalarapcLocalDisplayIdentDisplayType | read-only | mandatory | Numeric value used to identify the type of display in use. |
| 1.3.6.1.4.1.318.1.1.21.1.2 | ScalarapcLocalDisplayIdentModelNumber | read-only | mandatory | The model number of the local display. |
| 1.3.6.1.4.1.318.1.1.21.1.3 | ScalarapcLocalDisplayIdentFirmwareRev | read-only | mandatory | The firmware revision number of the local display. |
| 1.3.6.1.4.1.318.1.1.21.1.4 | ScalarapcLocalDisplayIdentOptions | read-only | mandatory | A display-specific string identifying options in the local display. |
| 1.3.6.1.4.1.318.1.1.21.1.5 | ScalarapcLocalDisplayIdentDateOfManufacture | read-only | mandatory | The date of manufacture of the local display, if available. |
| 1.3.6.1.4.1.318.1.1.21.1.6 | ScalarapcLocalDisplayIdentSerialNumber | read-only | mandatory | The serial number of the local display, if available. |
| 1.3.6.1.4.1.318.1.1.21.2 | NodeapcLocalDisplayConfig | |||
| 1.3.6.1.4.1.318.1.1.21.2.1 | ScalarapcLocalDisplayConfigAlarmBeeper | read-write | mandatory | The alarm beeper setting for the local display. When enabled, the alarm beeper will begin to sound whenever there a new alarm becomes active. The alarm beeper … |
| 1.3.6.1.4.1.318.1.1.21.2.2 | ScalarapcLocalDisplayConfigBeeperVolume | read-write | mandatory | The volume setting of the beeper on the local display. |
| 1.3.6.1.4.1.318.1.1.21.2.3 | ScalarapcLocalDisplayConfigCheckLogIndicator | read-write | mandatory | The minimum level event severity level required to illuminate the check log light on the local display. notPresent (1) indicates that the display does not have… |
| 1.3.6.1.4.1.318.1.1.21.2.4 | ScalarapcLocalDisplayConfigKeyClick | read-write | mandatory | The key click setting of the local display. |
| 1.3.6.1.4.1.318.1.1.21.2.5 | ScalarapcLocalDisplayConfigContrast | read-write | mandatory | The contrast level of the local display. |
| 1.3.6.1.4.1.318.1.1.22 | NodeisxModularDistribution | |||
| 1.3.6.1.4.1.318.1.1.22.1 | NodeisxModularDistInfo | |||
| 1.3.6.1.4.1.318.1.1.22.1.1 | ScalarisxModularDistInfoTableSize | read-only | mandatory | The number of entries in the isxModularDistInfoTable. |
| 1.3.6.1.4.1.318.1.1.22.1.2 | TableisxModularDistInfoTable | not-accessible | mandatory | Allows for getting information about the modular distribution metering equipment. |
| 1.3.6.1.4.1.318.1.1.22.1.2.1 | RowisxModularDistInfoEntry | not-accessible | mandatory | An entry containing information about an individual metering segment. |
| 1.3.6.1.4.1.318.1.1.22.1.2.1.1 | ColumnisxModularDistInfoSegmentIndex | read-only | mandatory | The index of the metering segment. |
| 1.3.6.1.4.1.318.1.1.22.1.2.1.2 | ColumnisxModularDistInfoMeterModelNumber | read-only | mandatory | The model number of the metering board for this segment. |
| 1.3.6.1.4.1.318.1.1.22.1.2.1.3 | ColumnisxModularDistInfoMeterSerialNumber | read-only | mandatory | The serial number of the metering board for this segment. |
| 1.3.6.1.4.1.318.1.1.22.1.2.1.4 | ColumnisxModularDistInfoMeterDateOfManufacture | read-only | mandatory | The date of manufacture for the metering board for this segment, in the format mm/dd/yyyy. |
| 1.3.6.1.4.1.318.1.1.22.1.2.1.5 | ColumnisxModularDistInfoMeterFirmwareRev | read-only | mandatory | The firmware revision number of the metering board for this segment. |
| 1.3.6.1.4.1.318.1.1.22.1.2.1.6 | ColumnisxModularDistInfoMeterHardwareRev | read-only | mandatory | The hardware revision number of the metering board for this segment. |
| 1.3.6.1.4.1.318.1.1.22.2 | NodeisxModularDistModules | |||
| 1.3.6.1.4.1.318.1.1.22.2.1 | ScalarisxModularDistModuleInfoTableSize | read-only | mandatory | The number of entries in the isxModularDistModuleInfoTable. |
| 1.3.6.1.4.1.318.1.1.22.2.2 | TableisxModularDistModuleInfoTable | not-accessible | mandatory | Allows for getting basic information about the distribution modules installed in the system. |
| 1.3.6.1.4.1.318.1.1.22.2.2.1 | RowisxModularDistModuleInfoEntry | not-accessible | mandatory | An entry containing information about a specific distribution module. |
| 1.3.6.1.4.1.318.1.1.22.2.2.1.1 | ColumnisxModularDistModuleInfoModIndex | read-only | mandatory | The number of the distribution module. |
| 1.3.6.1.4.1.318.1.1.22.2.2.1.2 | ColumnisxModularDistModuleInfoAlarmStatus | read-only | mandatory | The status of this module. This reflects the indicator lamp(s) on the front of the module. A value of notPresent indicates that the module is not installed. A … |
| 1.3.6.1.4.1.318.1.1.22.2.2.1.3 | ColumnisxModularDistModuleInfoModelNumber | read-only | mandatory | The model number of the distribution module. |
| 1.3.6.1.4.1.318.1.1.22.2.2.1.4 | ColumnisxModularDistModuleInfoSerialNumber | read-only | mandatory | The serial number of the distribution module. |
| 1.3.6.1.4.1.318.1.1.22.2.2.1.5 | ColumnisxModularDistModuleInfoDateOfManufacture | read-only | mandatory | The date that the distribution module was manufactured. |
| 1.3.6.1.4.1.318.1.1.22.2.2.1.6 | ColumnisxModularDistModuleInfoNumCables | read-only | mandatory | The number of cables provided by this distribution module. |
| 1.3.6.1.4.1.318.1.1.22.2.3 | ScalarisxModularDistModuleBreakerTableSize | read-only | mandatory | The number of entries in the isxModularDistModuleBreakerTable. |
| 1.3.6.1.4.1.318.1.1.22.2.4 | TableisxModularDistModuleBreakerTable | not-accessible | mandatory | Allows for getting operational information about the distribution modules. |
| 1.3.6.1.4.1.318.1.1.22.2.4.1 | RowisxModularDistModuleBreakerEntry | not-accessible | mandatory | An entry containing information about a specific distribution modules and circuit breakers. |
| 1.3.6.1.4.1.318.1.1.22.2.4.1.1 | ColumnisxModularDistModuleBreakerModIndex | read-only | mandatory | The distribution module number. |
| 1.3.6.1.4.1.318.1.1.22.2.4.1.2 | ColumnisxModularDistModuleBreakerPhaseIndex | read-only | mandatory | The index to an individual breaker in the distribution module. The index also corresponds to the system phase to which the breaker is attached. |
| 1.3.6.1.4.1.318.1.1.22.2.4.1.3 | ColumnisxModularDistModuleBreakerAlarmStatus | read-only | mandatory | This is a bit map representing the active alarms for this breaker: b0 - Minimum current threshold exceeded (critical) b1 - Low current threshold exceeded (warn… |
| 1.3.6.1.4.1.318.1.1.22.2.4.1.4 | ColumnisxModularDistModuleBreakerRating | read-only | mandatory | The current rating of the breaker. |
| 1.3.6.1.4.1.318.1.1.22.2.4.1.5 | ColumnisxModularDistModuleBreakerPhysicalGroup | read-only | mandatory | Numeric value used to indicate that a breaker is a part of a multi-pole breaker. Breakers within a distribution module, with equivalent physical group numbers,… |
| 1.3.6.1.4.1.318.1.1.22.2.4.1.6 | ColumnisxModularDistModuleBreakerCableNum | read-only | mandatory | Numeric value used to indicate the distribution cable to which this breaker is connected. These distribution cables are described in the table isxModularDistMo… |
| 1.3.6.1.4.1.318.1.1.22.2.4.1.7 | ColumnisxModularDistModuleBreakerPosition | read-only | mandatory | The physical status of this breaker pole, either closed or open (including tripped). |
| 1.3.6.1.4.1.318.1.1.22.2.4.1.8 | ColumnisxModularDistModuleBreakerPositionAlarms | read-write | mandatory | Enable or disable breaker position alarms for this circuit breaker. |
| 1.3.6.1.4.1.318.1.1.22.2.4.1.9 | ColumnisxModularDistModuleBreakerCurrent | read-only | mandatory | The current flowing though this breaker. Measured in tenths of amps. |
| 1.3.6.1.4.1.318.1.1.22.2.4.1.10 | ColumnisxModularDistModuleBreakerPercent | read-only | mandatory | The loading on this breaker as a percentage of the breaker's current rating. Expressed in tenths of percent. |
| 1.3.6.1.4.1.318.1.1.22.2.4.1.11 | ColumnisxModularDistModuleBreakerPower | read-only | mandatory | The power being supplied through this breaker. Measured in tenths of kW. |
| 1.3.6.1.4.1.318.1.1.22.2.5 | ScalarisxModularDistModuleOutputsTableSize | read-only | mandatory | The number of entries in the isxModularDistModuleOutputTable. |
| 1.3.6.1.4.1.318.1.1.22.2.6 | TableisxModularDistModuleOutputTable | not-accessible | mandatory | Allows for getting and setting information related to the load equipment being fed by the distribution modules in the ISX Modular Distribution System. |
| 1.3.6.1.4.1.318.1.1.22.2.6.1 | RowisxModularDistModuleOutputEntry | not-accessible | mandatory | An entry containing information about a specific distribution module and its output distribution cables. |
| 1.3.6.1.4.1.318.1.1.22.2.6.1.1 | ColumnisxModularDistModuleOutputModIndex | read-only | mandatory | The number of the distribution module supplying power to the load equipment. |
| 1.3.6.1.4.1.318.1.1.22.2.6.1.2 | ColumnisxModularDistModuleOutputNumCables | read-only | mandatory | The number of distribution cables provided by this module. |
| 1.3.6.1.4.1.318.1.1.22.2.6.1.3 | ColumnisxModularDistModuleOutputCordIndex | read-only | mandatory | The index of an individual distribution cable supplied by this module. |
| 1.3.6.1.4.1.318.1.1.22.2.6.1.4 | ColumnisxModularDistModuleOutputName | read-write | mandatory | A string describing the load equipment being supplied by this distribution cable. |
| 1.3.6.1.4.1.318.1.1.22.2.6.1.5 | ColumnisxModularDistModuleOutputLocation | read-write | mandatory | A string describing the location of equipment being supplied by distribution cable. |
| 1.3.6.1.4.1.318.1.1.22.2.6.1.6 | ColumnisxModularDistModuleOutputStatus | read-only | mandatory | This reflects the worse case severity for alarms associated with this distribution cable. A value of notPresent indicates that the cable does not exist for thi… |
| 1.3.6.1.4.1.318.1.1.22.2.6.1.7 | ColumnisxModularDistModuleOutputAlarmGeneration | read-write | mandatory | Enable or disable all alarm generation related to this distribution cable. |
| 1.3.6.1.4.1.318.1.1.22.2.6.1.8 | ColumnisxModularDistModuleOutputBreakerMap | read-only | mandatory | This is a bit map representing the breaker poles within the module that are associated with this distribution cable. The following 3 bits are used to indicate … |
| 1.3.6.1.4.1.318.1.1.22.2.6.1.9 | ColumnisxModularDistModuleOutputThresholdMin | read-write | mandatory | When the current drops below this value a critical alarm will exist. |
| 1.3.6.1.4.1.318.1.1.22.2.6.1.10 | ColumnisxModularDistModuleOutputThresholdLow | read-write | mandatory | When the current drops below this value a warning alarm will exist. |
| 1.3.6.1.4.1.318.1.1.22.2.6.1.11 | ColumnisxModularDistModuleOutputThresholdHigh | read-write | mandatory | When the current exceeds this value a warning alarm will exist. |
| 1.3.6.1.4.1.318.1.1.22.2.6.1.12 | ColumnisxModularDistModuleOutputThresholdMax | read-write | mandatory | When the current exceeds this value a critical alarm will exist. |
| 1.3.6.1.4.1.318.1.1.22.2.6.1.13 | ColumnisxModularDistModuleOutputAlarmMinEnable | read-write | mandatory | Enable or disable minimum current alarm generation for this distribution cable. |
| 1.3.6.1.4.1.318.1.1.22.2.6.1.14 | ColumnisxModularDistModuleOutputAlarmLowEnable | read-write | mandatory | Enable or disable low current alarm generation for this distribution cable. |
| 1.3.6.1.4.1.318.1.1.22.2.6.1.15 | ColumnisxModularDistModuleOutputAlarmHighEnable | read-write | mandatory | Enable or disable high current alarm generation for this distribution cable. |
| 1.3.6.1.4.1.318.1.1.22.2.6.1.16 | ColumnisxModularDistModuleOutputAlarmMaxEnable | read-write | mandatory | Enable or disable maximum current alarm generation for this distribution cable. |
| 1.3.6.1.4.1.318.1.1.22.2.6.1.17 | ColumnisxModularDistModuleOutputCableLength | read-only | mandatory | The length of this distribution cable. Specified in tenths of meters. |
| 1.3.6.1.4.1.318.1.1.22.2.6.1.18 | ColumnisxModularDistModuleOutputConnectorType | read-only | mandatory | A string describing the connector on the end of this distribution cable. |
| 1.3.6.1.4.1.318.1.1.22.2.6.1.19 | ColumnisxModularDistModuleOutputAvailableVoltages | read-only | mandatory | This is a bit map representing the voltages that are available at the connector. 6 bits are used to indicate the following: b0 - L1 b1 - L2 b2 - L3 b3 - L1-2 b… |
| 1.3.6.1.4.1.318.1.1.22.2.6.1.20 | ColumnisxModularDistModuleOutputTotalPower | read-only | mandatory | The total power being consumed by the load equipment supplied by this distribution cable. Measured in tenths of kW. |
| 1.3.6.1.4.1.318.1.1.22.2.6.1.21 | ColumnisxModularDistModuleOutputKwhUsage | read-only | mandatory | The total energy consumed by the load equipment fed by this distribution cable. This is the total since the date specified in the isxModularDistModuleOutputKwh… |
| 1.3.6.1.4.1.318.1.1.22.2.6.1.22 | ColumnisxModularDistModuleOutputKwhReset | read-write | mandatory | Writing yes to this OID will reset the total kWh usage shown in the isxModularDistModuleOutputKwhUsage OID. |
| 1.3.6.1.4.1.318.1.1.22.2.6.1.23 | ColumnisxModularDistModuleOutputKwhResetDate | read-only | mandatory | The date that the kWh usage was reset, in the format mm/dd/yyyy. Example: 01/01/2000. |
| 1.3.6.1.4.1.318.1.1.22.3 | NodeisxModularDistSubFeeds | |||
| 1.3.6.1.4.1.318.1.1.22.3.1 | ScalarisxModularDistSubFeedInfoTableSize | read-only | mandatory | The number of entries in the isxModularDistSubFeedInfoTable. |
| 1.3.6.1.4.1.318.1.1.22.3.2 | TableisxModularDistSubFeedInfoTable | not-accessible | mandatory | Allows for getting information about distribution subfeed breakers. |
| 1.3.6.1.4.1.318.1.1.22.3.2.1 | RowisxModularDistSubFeedInfoEntry | not-accessible | mandatory | An entry containing information about a specific distribution subfeed. |
| 1.3.6.1.4.1.318.1.1.22.3.2.1.1 | ColumnisxModularDistSubFeedInfoSubIndex | read-only | mandatory | The index of an individual subfeed. |
| 1.3.6.1.4.1.318.1.1.22.3.2.1.2 | ColumnisxModularDistSubFeedInfoName | read-write | mandatory | A string describing the load equipment being supplied by this subfeed. |
| 1.3.6.1.4.1.318.1.1.22.3.2.1.3 | ColumnisxModularDistSubFeedInfoLocation | read-write | mandatory | A string describing the location of the equipment being supplied by this subfeed. |
| 1.3.6.1.4.1.318.1.1.22.3.2.1.4 | ColumnisxModularDistSubFeedInfoBreakerRating | read-only | mandatory | The current rating of this subfeed breaker. |
| 1.3.6.1.4.1.318.1.1.22.3.2.1.5 | ColumnisxModularDistSubFeedInfoBreakerPosition | read-only | mandatory | The operational status of this breaker, either closed or open (including tripped). |
| 1.3.6.1.4.1.318.1.1.22.3.2.1.6 | ColumnisxModularDistSubFeedInfoAlarmStatus | read-only | mandatory | The worst case alarm status for this subfeed. |
| 1.3.6.1.4.1.318.1.1.22.3.2.1.7 | ColumnisxModularDistSubFeedInfoAlarmGeneration | read-write | mandatory | Enable or disable all alarm generation related to this subfeed. |
| 1.3.6.1.4.1.318.1.1.22.3.2.1.8 | ColumnisxModularDistSubFeedInfoThresholdMin | read-write | mandatory | When the current drops below this value a critical alarm will exist. |
| 1.3.6.1.4.1.318.1.1.22.3.2.1.9 | ColumnisxModularDistSubFeedInfoThresholdLow | read-write | mandatory | When the current drops below this value a warning alarm will exist. |
| 1.3.6.1.4.1.318.1.1.22.3.2.1.10 | ColumnisxModularDistSubFeedInfoThresholdHigh | read-write | mandatory | When the current exceeds this value a warning alarm will exist. |
| 1.3.6.1.4.1.318.1.1.22.3.2.1.11 | ColumnisxModularDistSubFeedInfoThresholdMax | read-write | mandatory | When the current exceeds this value a critical alarm will exist. |
| 1.3.6.1.4.1.318.1.1.22.3.2.1.12 | ColumnisxModularDistSubFeedInfoAlarmMinEnable | read-write | mandatory | Enable or disable minimum current alarm generation for this subfeed. |
| 1.3.6.1.4.1.318.1.1.22.3.2.1.13 | ColumnisxModularDistSubFeedInfoAlarmLowEnable | read-write | mandatory | Enable or disable low current alarm generation for this subfeed. |
| 1.3.6.1.4.1.318.1.1.22.3.2.1.14 | ColumnisxModularDistSubFeedInfoAlarmHighEnable | read-write | mandatory | Enable or disable high current alarm generation for this subfeed. |
| 1.3.6.1.4.1.318.1.1.22.3.2.1.15 | ColumnisxModularDistSubFeedInfoAlarmMaxEnable | read-write | mandatory | Enable or disable maximum current alarm generation for this subfeed. |
| 1.3.6.1.4.1.318.1.1.22.3.2.1.16 | ColumnisxModularDistSubFeedInfoBreakerAlarmEnable | read-write | mandatory | Enable or disable breaker position alarms for this subfeed. |
| 1.3.6.1.4.1.318.1.1.22.3.2.1.17 | ColumnisxModularDistSubFeedInfoTotalPower | read-only | mandatory | The total power being supplied by this subfeed. Measured in tenths of kW. |
| 1.3.6.1.4.1.318.1.1.22.3.2.1.18 | ColumnisxModularDistSubFeedInfoKwhUsage | read-only | mandatory | The total energy consumed by the load equipment fed by this subfeed. This is the total since the date specified in the isxModularDistSubFeedInfoKwhResetDate OI… |
| 1.3.6.1.4.1.318.1.1.22.3.2.1.19 | ColumnisxModularDistSubFeedInfoKwhReset | read-write | mandatory | Writing yes to this OID will reset the total kWh usage shown in the isxModularDistSubFeedInfoKwhUsage OID. |
| 1.3.6.1.4.1.318.1.1.22.3.2.1.20 | ColumnisxModularDistSubFeedInfoKwhResetDate | read-only | mandatory | The date that the kWh usage was reset, in the format mm/dd/yyyy. Example: 01/01/2000. |
| 1.3.6.1.4.1.318.1.1.22.3.3 | ScalarisxModularDistSubFeedLoadingTableSize | read-only | mandatory | The number of entries in the isxModularDistSubFeedLoadingTable. |
| 1.3.6.1.4.1.318.1.1.22.3.4 | TableisxModularDistSubFeedLoadingTable | not-accessible | mandatory | Allows for getting subfeed phase loading information. |
| 1.3.6.1.4.1.318.1.1.22.3.4.1 | RowisxModularDistSubFeedLoadingEntry | not-accessible | mandatory | An entry containing data for an individual subfeed. |
| 1.3.6.1.4.1.318.1.1.22.3.4.1.1 | ColumnisxModularDistSubFeedLoadingSubIndex | read-only | mandatory | The index of an individual subfeed. |
| 1.3.6.1.4.1.318.1.1.22.3.4.1.2 | ColumnisxModularDistSubFeedLoadingPhaseIndex | read-only | mandatory | Description of each input phase entry in the table. |
| 1.3.6.1.4.1.318.1.1.22.3.4.1.3 | ColumnisxModularDistSubFeedLoadingAlarmStatus | read-only | mandatory | This is a bit map representing the active alarms for this subfeed: b0 - Minimum current threshold exceeded (critical) b1 - Low current threshold exceeded (warn… |
| 1.3.6.1.4.1.318.1.1.22.3.4.1.4 | ColumnisxModularDistSubFeedLoadingCurrent | read-only | mandatory | The current flowing though this subfeed phase. Measured in tenths of amps. |
| 1.3.6.1.4.1.318.1.1.22.3.4.1.5 | ColumnisxModularDistSubFeedLoadingPercent | read-only | mandatory | The loading on this subfeed phase as a percentage of the subfeed's current rating. Expressed in tenths of percent. |
| 1.3.6.1.4.1.318.1.1.22.3.4.1.6 | ColumnisxModularDistSubFeedLoadingPower | read-only | mandatory | The power being supplied by this subfeed phase. Measured in tenths of kW. |
| 1.3.6.1.4.1.318.1.1.22.4 | NodeisxModularDistTotals | |||
| 1.3.6.1.4.1.318.1.1.22.4.1 | NodeisxModularDistSysVoltage | |||
| 1.3.6.1.4.1.318.1.1.22.4.1.1 | ScalarisxModularDistSysOutputVoltageNominalLineToNeutral | read-only | mandatory | The nominal line-to-neutral voltage available at the distribution panel. |
| 1.3.6.1.4.1.318.1.1.22.4.1.2 | ScalarisxModularDistSysOutputVoltageNominalLineToLine | read-only | mandatory | The nominal line-to-line voltage available at the distribution panel. |
| 1.3.6.1.4.1.318.1.1.22.4.1.3 | ScalarisxModularDistSysOutputNominalFrequency | read-only | mandatory | The nominal system output frequency. Measured in tenths of Hertz. |
| 1.3.6.1.4.1.318.1.1.22.4.1.4 | ScalarisxModularDistSysOutputFrequency | read-only | mandatory | The system output frequency in tenths of Hertz. -1 if not available. |
| 1.3.6.1.4.1.318.1.1.22.4.1.5 | ScalarisxModularDistSysOutputVoltageMonitoring | read-only | mandatory | Indicates whether or not output voltage alarm generation is present. |
| 1.3.6.1.4.1.318.1.1.22.4.1.6 | ScalarisxModularDistSysOutputVoltageThresholdMin | read-write | mandatory | When the line-to-neutral voltage of any phase drops below this value a critical alarm will exist. Specified as a percent of the nominal voltage, isxModularDist… |
| 1.3.6.1.4.1.318.1.1.22.4.1.7 | ScalarisxModularDistSysOutputVoltageThresholdLow | read-write | mandatory | When the line-to-neutral voltage of any phase drops below this value a warning alarm will exist. Specified as a percent of the nominal voltage, isxModularDistS… |
| 1.3.6.1.4.1.318.1.1.22.4.1.8 | ScalarisxModularDistSysOutputVoltageThresholdHigh | read-write | mandatory | When the line-to-neutral voltage of any phase exceeds this value a warning alarm will exist. Specified as a percent of the nominal voltage, isxModularDistSysOu… |
| 1.3.6.1.4.1.318.1.1.22.4.1.9 | ScalarisxModularDistSysOutputVoltageThresholdMax | read-write | mandatory | When the line-to-neutral voltage of any phase exceeds this value a critical alarm will exist. Specified as a percent of the nominal voltage, isxModularDistSysO… |
| 1.3.6.1.4.1.318.1.1.22.4.1.10 | ScalarisxModularDistSysOutputVoltageAlarmMinEnable | read-write | mandatory | Enable or disable minimum voltage alarm generation for the distribution panel. |
| 1.3.6.1.4.1.318.1.1.22.4.1.11 | ScalarisxModularDistSysOutputVoltageAlarmLowEnable | read-write | mandatory | Enable or disable low voltage alarm generation for the distribution panel. |
| 1.3.6.1.4.1.318.1.1.22.4.1.12 | ScalarisxModularDistSysOutputVoltageAlarmHighEnable | read-write | mandatory | Enable or disable high voltage alarm generation for the distribution panel. |
| 1.3.6.1.4.1.318.1.1.22.4.1.13 | ScalarisxModularDistSysOutputVoltageAlarmMaxEnable | read-write | mandatory | Enable or disable maximum voltage alarm generation for the distribution panel. |
| 1.3.6.1.4.1.318.1.1.22.4.1.14 | ScalarisxModularDistSysOutputVoltageFrequencyTolerance | read-write | mandatory | The circuit panel output frequency tolerance in Hertz. When the system output frequency deviates from the nominal by more than this range, a critical alarm wil… |
| 1.3.6.1.4.1.318.1.1.22.4.1.15 | TableisxModularDistSysVoltageTable | not-accessible | mandatory | Allows for getting the system output voltage information. |
| 1.3.6.1.4.1.318.1.1.22.4.1.15.1 | RowisxModularDistSysVoltageEntry | not-accessible | mandatory | An entry containing data for an individual system output phase. |
| 1.3.6.1.4.1.318.1.1.22.4.1.15.1.1 | ColumnisxModularDistSysVoltagePhaseIndex | read-only | mandatory | Description of each phase entry in the table. |
| 1.3.6.1.4.1.318.1.1.22.4.1.15.1.2 | ColumnisxModularDistSysVoltageAlarmStatus | read-only | mandatory | This is a bit map representing the active alarms for this output phase: b0 - Minimum voltage threshold exceeded (critical) b1 - Low voltage threshold exceeded … |
| 1.3.6.1.4.1.318.1.1.22.4.1.15.1.3 | ColumnisxModularDistSysVoltageLtoN | read-only | mandatory | Line-to-neutral system output voltage available at the distribution panel. Measured in tenths of Volts. |
| 1.3.6.1.4.1.318.1.1.22.4.1.15.1.4 | ColumnisxModularDistSysVoltageLtoL | read-only | mandatory | Line-to-line system output voltage available at the distribution panel. Measured in tenths of Volts. |
| 1.3.6.1.4.1.318.1.1.22.4.2 | NodeisxModularDistSysCurrent | |||
| 1.3.6.1.4.1.318.1.1.22.4.2.1 | ScalarisxModularDistSysCurrentRating | read-only | mandatory | The 100 percent current rating of the distribution panel. |
| 1.3.6.1.4.1.318.1.1.22.4.2.2 | ScalarisxModularDistSysCurrentMonitoring | read-only | mandatory | Indicates whether or not total output current measurements and alarm generation are present. |
| 1.3.6.1.4.1.318.1.1.22.4.2.3 | ScalarisxModularDistSysCurrentThresholdMin | read-write | mandatory | When total system current in any phase drops below this value a critical alarm will exist. Specified as a percent of the panel rating, isxModularDistSysCurrent… |
| 1.3.6.1.4.1.318.1.1.22.4.2.4 | ScalarisxModularDistSysCurrentThresholdLow | read-write | mandatory | When total system current in any phase drops below this value a warning alarm will exist. Specified as a percent of the panel rating, isxModularDistSysCurrentR… |
| 1.3.6.1.4.1.318.1.1.22.4.2.5 | ScalarisxModularDistSysCurrentThresholdHigh | read-write | mandatory | When total system current in any phase exceeds this value a warning alarm will exist. Specified as a percent of the panel rating, isxModularDistSysCurrentRatin… |
| 1.3.6.1.4.1.318.1.1.22.4.2.6 | ScalarisxModularDistSysCurrentThresholdMax | read-write | mandatory | When total system current in any phase exceeds this value a critical alarm will exist. Specified as a percent of the panel rating, isxModularDistSysCurrentRati… |
| 1.3.6.1.4.1.318.1.1.22.4.2.7 | ScalarisxModularDistSysCurrentAlarmMinEnable | read-write | mandatory | Enable or disable minimum total output current alarm generation. |
| 1.3.6.1.4.1.318.1.1.22.4.2.8 | ScalarisxModularDistSysCurrentAlarmLowEnable | read-write | mandatory | Enable or disable low total output current alarm generation. |
| 1.3.6.1.4.1.318.1.1.22.4.2.9 | ScalarisxModularDistSysCurrentAlarmHighEnable | read-write | mandatory | Enable or disable high total output current alarm generation. |
| 1.3.6.1.4.1.318.1.1.22.4.2.10 | ScalarisxModularDistSysCurrentAlarmMaxEnable | read-write | mandatory | Enable or disable maximum total output current alarm generation. |
| 1.3.6.1.4.1.318.1.1.22.4.2.11 | TableisxModularDistSysCurrentTable | not-accessible | mandatory | Allows for getting the total system phase current information. |
| 1.3.6.1.4.1.318.1.1.22.4.2.11.1 | RowisxModularDistSysCurrentEntry | not-accessible | mandatory | An entry containing data for an individual system output phase. |
| 1.3.6.1.4.1.318.1.1.22.4.2.11.1.1 | ColumnisxModularDistSysCurrentPhaseIndex | read-only | mandatory | Description of each phase entry in the table. |
| 1.3.6.1.4.1.318.1.1.22.4.2.11.1.2 | ColumnisxModularDistSysCurrentAlarmStatus | read-only | mandatory | This is a bit map representing the active alarms for this output phase: b0 - Minimum current threshold exceeded (critical) b1 - Low current threshold exceeded … |
| 1.3.6.1.4.1.318.1.1.22.4.2.11.1.3 | ColumnisxModularDistSysCurrentAmps | read-only | mandatory | The current flowing though this system output phase. Measured in tenths of amps. |
| 1.3.6.1.4.1.318.1.1.22.4.2.11.1.4 | ColumnisxModularDistSysCurrentPercent | read-only | mandatory | The loading on this system output phase as a percentage of the panel current rating. Expressed in tenths of percent. |
| 1.3.6.1.4.1.318.1.1.22.4.3 | NodeisxModularDistSysPower | |||
| 1.3.6.1.4.1.318.1.1.22.4.3.1 | ScalarisxModularDistSysPowerTotal | read-only | mandatory | The total system power being supplied. Measured in tenths of kW. |
| 1.3.6.1.4.1.318.1.1.22.4.3.2 | ScalarisxModularDistSysPowerKwhUsage | read-only | mandatory | The total system energy consumed by the load equipment. This is the total since the date specified in the isxModularDistSysOutputKwhResetDate OID, and may be c… |
| 1.3.6.1.4.1.318.1.1.22.4.3.3 | ScalarisxModularDistSysPowerKwhReset | read-write | mandatory | Writing yes to this OID will reset the total kWh usage shown in the isxModularDistSysPowerKwhUsage OID. |
| 1.3.6.1.4.1.318.1.1.22.4.3.4 | ScalarisxModularDistSysPowerKwhResetDate | read-only | mandatory | The date that the kWh usage was reset, in the format mm/dd/yyyy. Example: 01/01/2000. |
| 1.3.6.1.4.1.318.1.1.22.4.3.5 | TableisxModularDistSysPowerTable | not-accessible | mandatory | Allows for getting the total system phase power loading information. |
| 1.3.6.1.4.1.318.1.1.22.4.3.5.1 | RowisxModularDistSysPowerEntry | not-accessible | mandatory | An entry containing data for an individual system output phase. |
| 1.3.6.1.4.1.318.1.1.22.4.3.5.1.1 | ColumnisxModularDistSysPowerPhaseIndex | read-only | mandatory | Description of each phase entry in the table. |
| 1.3.6.1.4.1.318.1.1.22.4.3.5.1.2 | ColumnisxModularDistSysPowerKw | read-only | mandatory | The power being supplied by this system output phase. Measured in tenths of kW. |
| 1.3.6.1.4.1.318.1.1.22.4.3.5.1.3 | ColumnisxModularDistSysPowerKwhPhaseUsage | read-only | mandatory | The energy consumed by the load equipment on this system output phase. This is the total since the date specified in the isxModularDistSysPowerKwhResetDate OID… |
| 1.3.6.1.4.1.318.1.1.23 | NodeisxModularPdu | |||
| 1.3.6.1.4.1.318.1.1.23.1 | NodeisxModularPduIdent | |||
| 1.3.6.1.4.1.318.1.1.23.1.1 | ScalarisxModularPduIdentModelNumber | read-only | mandatory | A character string identifying the model number of the PDU. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.23.1.2 | ScalarisxModularPduIdentSerialNumber | read-only | mandatory | A character string identifying the serial number of the PDU. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.23.1.3 | ScalarisxModularPduIdentDateOfManufacture | read-only | mandatory | The date when the PDU was manufactured in mm/dd/yyyy format. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.23.1.4 | ScalarisxModularPduIdentMonitorCardSerialNumber | read-only | mandatory | A character string identifying the serial number of the PDU monitor card. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.23.1.5 | ScalarisxModularPduIdentMonitorCardHardwareRev | read-only | mandatory | The hardware revision of the PDU monitor card. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.23.1.6 | ScalarisxModularPduIdentMonitorCardFirmwareAppRev | read-only | mandatory | An ID string identifying the application firmware revision of the PDU monitor card. |
| 1.3.6.1.4.1.318.1.1.23.1.7 | ScalarisxModularPduIdentMonitorCardFirmwareAppOSRev | read-only | mandatory | An ID string identifying the application operating system firmware revision of the PDU monitor card. |
| 1.3.6.1.4.1.318.1.1.23.2 | NodeisxModularPduDevice | |||
| 1.3.6.1.4.1.318.1.1.23.2.1 | ScalarisxModularPduDeviceTransformerPresent | read-only | mandatory | Indicates the type of transformer present in this PDU. |
| 1.3.6.1.4.1.318.1.1.23.2.2 | ScalarisxModularPduDeviceServiceType | read-only | mandatory | The type of utility input to the PDU. Either 3 wires (delta), or 4 wires (wye). |
| 1.3.6.1.4.1.318.1.1.23.2.3 | ScalarisxModularPduDeviceFansPresent | read-only | mandatory | Indicates whether or not cooling fans are installed in the PDU. |
| 1.3.6.1.4.1.318.1.1.23.2.4 | ScalarisxModularPduDeviceNominalMainInputVoltage | read-only | mandatory | The nominal main input voltage to the system. Measured in Volts, line-to-line for a 3-wire (delta) service or line-to-neutral for a 4-wire (wye) service. -1 if… |
| 1.3.6.1.4.1.318.1.1.23.3 | NodeisxModularPduStatus | |||
| 1.3.6.1.4.1.318.1.1.23.3.1 | ScalarisxModularPduAlarmStatus | read-only | mandatory | The overall status (worst case) of this PDU. |
| 1.3.6.1.4.1.318.1.1.23.3.2 | ScalarisxModularPduTransformerTempStatus | read-only | mandatory | Indicates if the PDU isolation transformer is over temperature. |
| 1.3.6.1.4.1.318.1.1.23.3.3 | ScalarisxModularPduFanStatus | read-only | mandatory | Indicates if one or more of the PDU's cooling fans have failed. |
| 1.3.6.1.4.1.318.1.1.25 | NodeuniversalInputOutput | |||
| 1.3.6.1.4.1.318.1.1.25.1 | NodeuioSensor | |||
| 1.3.6.1.4.1.318.1.1.25.1.1 | ScalaruioSensorStatusTableSize | read-only | mandatory | The number of entries in the uioSensorStatusTable. |
| 1.3.6.1.4.1.318.1.1.25.1.2 | TableuioSensorStatusTable | not-accessible | mandatory | Allows for getting sensor status information. |
| 1.3.6.1.4.1.318.1.1.25.1.2.1 | RowuioSensorStatusEntry | not-accessible | mandatory | The unit from which to get data. |
| 1.3.6.1.4.1.318.1.1.25.1.2.1.1 | ColumnuioSensorStatusPortID | read-only | mandatory | The ID of the port to which the sensor is attached. |
| 1.3.6.1.4.1.318.1.1.25.1.2.1.2 | ColumnuioSensorStatusSensorID | read-only | mandatory | The ID of the sensor. |
| 1.3.6.1.4.1.318.1.1.25.1.2.1.3 | ColumnuioSensorStatusSensorName | read-only | mandatory | The sensor name. |
| 1.3.6.1.4.1.318.1.1.25.1.2.1.4 | ColumnuioSensorStatusSensorLocation | read-only | mandatory | The location of the sensor. |
| 1.3.6.1.4.1.318.1.1.25.1.2.1.5 | ColumnuioSensorStatusTemperatureDegF | read-only | mandatory | The sensor's current temperature reading in degrees Fahrenheit. -1 indicates an invalid reading due to lost communications. |
| 1.3.6.1.4.1.318.1.1.25.1.2.1.6 | ColumnuioSensorStatusTemperatureDegC | read-only | mandatory | The sensor's current temperature reading in degrees Celsius. -1 indicates an invalid reading due to lost communications. |
| 1.3.6.1.4.1.318.1.1.25.1.2.1.7 | ColumnuioSensorStatusHumidity | read-only | mandatory | The sensor's current humidity reading in percent relative humidity. -1 indicates an invalid reading due to either a sensor that doesn't read humidity or lost c… |
| 1.3.6.1.4.1.318.1.1.25.1.2.1.8 | ColumnuioSensorStatusViolationStatus | read-only | mandatory | The violation status of the sensor. This integer should be interpreted as a bit map, with each bit representing the presence or absence of the specific alarm c… |
| 1.3.6.1.4.1.318.1.1.25.1.2.1.9 | ColumnuioSensorStatusAlarmStatus | read-only | mandatory | The alarm status of the sensor. |
| 1.3.6.1.4.1.318.1.1.25.1.2.1.10 | ColumnuioSensorStatusCommStatus | read-only | mandatory | The communications status of the sensor. |
| 1.3.6.1.4.1.318.1.1.25.1.3 | ScalaruioSensorConfigTableSize | read-only | mandatory | The number of entries in the uioSensorConfigTable. |
| 1.3.6.1.4.1.318.1.1.25.1.4 | TableuioSensorConfigTable | not-accessible | mandatory | Allows for configuring the sensor. |
| 1.3.6.1.4.1.318.1.1.25.1.4.1 | RowuioSensorConfigEntry | not-accessible | mandatory | The sensor from which to get configuration. |
| 1.3.6.1.4.1.318.1.1.25.1.4.1.1 | ColumnuioSensorConfigPortID | read-only | mandatory | The ID of the port to which the sensor is attached. |
| 1.3.6.1.4.1.318.1.1.25.1.4.1.2 | ColumnuioSensorConfigSensorID | read-only | mandatory | The ID of the sensor. |
| 1.3.6.1.4.1.318.1.1.25.1.4.1.3 | ColumnuioSensorConfigSensorName | read-write | mandatory | The sensor name. |
| 1.3.6.1.4.1.318.1.1.25.1.4.1.4 | ColumnuioSensorConfigSensorLocation | read-write | mandatory | The location of the sensor. |
| 1.3.6.1.4.1.318.1.1.25.1.4.1.5 | ColumnuioSensorConfigMinTemperatureThreshold | read-write | mandatory | The minimum (critical) temperature alarm threshold for the probe in degrees C. Must be lower than the low threshold to ensure proper sensor alarm behavior. |
| 1.3.6.1.4.1.318.1.1.25.1.4.1.6 | ColumnuioSensorConfigLowTemperatureThreshold | read-write | mandatory | The low (warning) temperature alarm threshold for the probe in degrees C. Must be higher than the minimum threshold and lower than the high threshold to ensure… |
| 1.3.6.1.4.1.318.1.1.25.1.4.1.7 | ColumnuioSensorConfigHighTemperatureThreshold | read-write | mandatory | The high (warning) temperature alarm threshold for the probe in degrees C. Must be lower than the maximum threshold and higher than the low threshold to ensure… |
| 1.3.6.1.4.1.318.1.1.25.1.4.1.8 | ColumnuioSensorConfigMaxTemperatureThreshold | read-write | mandatory | The maximum (critical) temperature alarm threshold for the probe in degrees C. Must be higher than the high threshold to ensure proper sensor alarm behavior. |
| 1.3.6.1.4.1.318.1.1.25.1.4.1.9 | ColumnuioSensorConfigTemperatureHysteresis | read-write | mandatory | The number of degrees C beyond the temperature thresholds at which an active temperature alarm will be cleared. This value applies to all temperature threshold… |
| 1.3.6.1.4.1.318.1.1.25.1.4.1.10 | ColumnuioSensorConfigMinTemperatureEnable | read-write | mandatory | The minimum temperature alarm enable/disable for the sensor. 1 - disabled 2 - enabled |
| 1.3.6.1.4.1.318.1.1.25.1.4.1.11 | ColumnuioSensorConfigLowTemperatureEnable | read-write | mandatory | The low temperature alarm enable/disable for the sensor. 1 - disabled 2 - enabled |
| 1.3.6.1.4.1.318.1.1.25.1.4.1.12 | ColumnuioSensorConfigHighTemperatureEnable | read-write | mandatory | The high temperature alarm enable/disable for the sensor. 1 - disabled 2 - enabled |
| 1.3.6.1.4.1.318.1.1.25.1.4.1.13 | ColumnuioSensorConfigMaxTemperatureEnable | read-write | mandatory | The maximum temperature alarm enable/disable for the sensor. 1 - disabled 2 - enabled |
| 1.3.6.1.4.1.318.1.1.25.1.4.1.14 | ColumnuioSensorConfigMinHumidityThreshold | read-write | mandatory | The minimum (critical) humidity alarm threshold for the probe in percent relative humidity. Must be lower than the low threshold to ensure proper sensor alarm … |
| 1.3.6.1.4.1.318.1.1.25.1.4.1.15 | ColumnuioSensorConfigLowHumidityThreshold | read-write | mandatory | The low (warning) humidity alarm threshold for the probe in percent relative humidity. Must be higher than the minimum threshold and lower than the high thresh… |
| 1.3.6.1.4.1.318.1.1.25.1.4.1.16 | ColumnuioSensorConfigHighHumidityThreshold | read-write | mandatory | The high (warning) humidity alarm threshold for the probe in percent relative humidity. Must be lower than the maximum threshold and higher than the low thresh… |
| 1.3.6.1.4.1.318.1.1.25.1.4.1.17 | ColumnuioSensorConfigMaxHumidityThreshold | read-write | mandatory | The maximum (critical) humidity alarm threshold for the probe in percent relative humidity. Must be higher than the high threshold to ensure proper sensor alar… |
| 1.3.6.1.4.1.318.1.1.25.1.4.1.18 | ColumnuioSensorConfigHumidityHysteresis | read-write | mandatory | The number of percent relative humidity beyond the humidity thresholds at which an active humidity alarm will be cleared. This value applies to all humidity th… |
| 1.3.6.1.4.1.318.1.1.25.1.4.1.19 | ColumnuioSensorConfigMinHumidityEnable | read-write | mandatory | The minimum humidity alarm enable/disable for the sensor. 1 - disabled (always set if the sensor doesn't read humidity) 2 - enabled |
| 1.3.6.1.4.1.318.1.1.25.1.4.1.20 | ColumnuioSensorConfigLowHumidityEnable | read-write | mandatory | The low humidity alarm enable/disable for the sensor. 1 - disabled (always set if the sensor doesn't read humidity) 2 - enabled |
| 1.3.6.1.4.1.318.1.1.25.1.4.1.21 | ColumnuioSensorConfigHighHumidityEnable | read-write | mandatory | The high humidity alarm enable/disable for the sensor. 1 - disabled (always set if the sensor doesn't read humidity) 2 - enabled |
| 1.3.6.1.4.1.318.1.1.25.1.4.1.22 | ColumnuioSensorConfigMaxHumidityEnable | read-write | mandatory | The maximum humidity alarm enable/disable for the sensor. 1 - disabled (always set if the sensor doesn't read humidity) 2 - enabled |
| 1.3.6.1.4.1.318.1.1.25.2 | NodeuioInputContact | |||
| 1.3.6.1.4.1.318.1.1.25.2.1 | ScalaruioInputContactStatusTableSize | read-only | mandatory | The number of entries in the uioInputContactStatusTable. |
| 1.3.6.1.4.1.318.1.1.25.2.2 | TableuioInputContactStatusTable | not-accessible | mandatory | Allows for getting input contact status information. |
| 1.3.6.1.4.1.318.1.1.25.2.2.1 | RowuioInputContactStatusEntry | not-accessible | mandatory | The input contact from which to get data. |
| 1.3.6.1.4.1.318.1.1.25.2.2.1.1 | ColumnuioInputContactStatusPortID | read-only | mandatory | The ID of the port to which the input contact is attached. |
| 1.3.6.1.4.1.318.1.1.25.2.2.1.2 | ColumnuioInputContactStatusContactID | read-only | mandatory | The ID of the input contact on the module. |
| 1.3.6.1.4.1.318.1.1.25.2.2.1.3 | ColumnuioInputContactStatusContactName | read-only | mandatory | The input contact name. |
| 1.3.6.1.4.1.318.1.1.25.2.2.1.4 | ColumnuioInputContactStatusContactLocation | read-only | mandatory | The location of the input contact. |
| 1.3.6.1.4.1.318.1.1.25.2.2.1.5 | ColumnuioInputContactStatusCurrentState | read-only | mandatory | The current state of the input contact. |
| 1.3.6.1.4.1.318.1.1.25.2.2.1.6 | ColumnuioInputContactStatusAlarmStatus | read-only | mandatory | The alarm status of the input contact. |
| 1.3.6.1.4.1.318.1.1.25.2.2.1.7 | ColumnuioInputContactStatusCommStatus | read-only | mandatory | The communications status of the input contact. |
| 1.3.6.1.4.1.318.1.1.25.2.3 | ScalaruioInputContactConfigTableSize | read-only | mandatory | The number of entries in the uioInputContactConfigTable. |
| 1.3.6.1.4.1.318.1.1.25.2.4 | TableuioInputContactConfigTable | not-accessible | mandatory | Allows for configuring the input contacts. |
| 1.3.6.1.4.1.318.1.1.25.2.4.1 | RowuioInputContactConfigEntry | not-accessible | mandatory | The input contact from which to get configuration. |
| 1.3.6.1.4.1.318.1.1.25.2.4.1.1 | ColumnuioInputContactConfigPortID | read-only | mandatory | The ID of the port to which the input contact is attached. |
| 1.3.6.1.4.1.318.1.1.25.2.4.1.2 | ColumnuioInputContactConfigContactID | read-only | mandatory | The ID of the input contact on the module. |
| 1.3.6.1.4.1.318.1.1.25.2.4.1.3 | ColumnuioInputContactConfigContactName | read-write | mandatory | The input contact name. |
| 1.3.6.1.4.1.318.1.1.25.2.4.1.4 | ColumnuioInputContactConfigContactLocation | read-write | mandatory | The location of the input contact. |
| 1.3.6.1.4.1.318.1.1.25.2.4.1.5 | ColumnuioInputContactConfigEnable | read-write | mandatory | Enable or disable this input contact. 1 - disabled 2 - enabled |
| 1.3.6.1.4.1.318.1.1.25.2.4.1.6 | ColumnuioInputContactConfigNormalState | read-write | mandatory | The normal (non-alarm) state of the input contact. 1 - normally open 2 - normally closed |
| 1.3.6.1.4.1.318.1.1.25.2.4.1.7 | ColumnuioInputContactConfigSeverity | read-write | mandatory | The severity of the alarm that this input contact will generate in the abnormal state. 1 - critical severity 2 - warning severity |
| 1.3.6.1.4.1.318.1.1.25.3 | NodeuioOutputRelay | |||
| 1.3.6.1.4.1.318.1.1.25.3.1 | ScalaruioOutputRelayStatusTableSize | read-only | mandatory | The number of entries in the uioOutputRelayStatusTable. |
| 1.3.6.1.4.1.318.1.1.25.3.2 | TableuioOutputRelayStatusTable | not-accessible | mandatory | Allows for getting output relay status information. |
| 1.3.6.1.4.1.318.1.1.25.3.2.1 | RowuioOutputRelayStatusEntry | not-accessible | mandatory | The unit from which to get data. |
| 1.3.6.1.4.1.318.1.1.25.3.2.1.1 | ColumnuioOutputRelayStatusPortID | read-only | mandatory | The ID of the port to which the output relay is attached. |
| 1.3.6.1.4.1.318.1.1.25.3.2.1.2 | ColumnuioOutputRelayStatusRelayID | read-only | mandatory | The ID of the output relay on the module. |
| 1.3.6.1.4.1.318.1.1.25.3.2.1.3 | ColumnuioOutputRelayStatusRelayName | read-only | mandatory | The output relay name. |
| 1.3.6.1.4.1.318.1.1.25.3.2.1.4 | ColumnuioOutputRelayStatusRelayLocation | read-only | mandatory | The location of the output relay. |
| 1.3.6.1.4.1.318.1.1.25.3.2.1.5 | ColumnuioOutputRelayStatusCurrentState | read-only | mandatory | The current state of the output relay. |
| 1.3.6.1.4.1.318.1.1.25.3.2.1.6 | ColumnuioOutputRelayStatusAlarmStatus | read-only | mandatory | The alarm status of the output relay. |
| 1.3.6.1.4.1.318.1.1.25.3.2.1.7 | ColumnuioOutputRelayStatusCommStatus | read-only | mandatory | The communications status of the output relay. |
| 1.3.6.1.4.1.318.1.1.25.3.3 | ScalaruioOutputRelayConfigTableSize | read-only | mandatory | The number of entries in the uioOutputRelayConfigTable. |
| 1.3.6.1.4.1.318.1.1.25.3.4 | TableuioOutputRelayConfigTable | not-accessible | mandatory | Allows for configuring the output relay. |
| 1.3.6.1.4.1.318.1.1.25.3.4.1 | RowuioOutputRelayConfigEntry | not-accessible | mandatory | The unit from which to get configuration. |
| 1.3.6.1.4.1.318.1.1.25.3.4.1.1 | ColumnuioOutputRelayConfigPortID | read-only | mandatory | The ID of the port to which the output relay is attached. |
| 1.3.6.1.4.1.318.1.1.25.3.4.1.2 | ColumnuioOutputRelayConfigRelayID | read-only | mandatory | The ID of the output relay on the module. |
| 1.3.6.1.4.1.318.1.1.25.3.4.1.3 | ColumnuioOutputRelayConfigRelayName | read-write | mandatory | The output relay name. |
| 1.3.6.1.4.1.318.1.1.25.3.4.1.4 | ColumnuioOutputRelayConfigRelayLocation | read-write | mandatory | The location of the output relay. |
| 1.3.6.1.4.1.318.1.1.25.3.4.1.5 | ColumnuioOutputRelayConfigNormalState | read-write | mandatory | The normal state of the output relay. 1 - normally open 2 - normally closed |
| 1.3.6.1.4.1.318.1.1.25.3.4.1.6 | ColumnuioOutputRelayConfigControlState | read-write | mandatory | Close or open the output relay for testing purposes. Always returns 1 when read. 1 - close output relay 2 - open output relay |
| 1.3.6.1.4.1.318.1.1.25.3.4.1.7 | ColumnuioOutputRelayConfigDelay | read-write | mandatory | The time a selected alarm condition must exist before the output relay is activated. Valid values are whole seconds from 0 to 65535. |
| 1.3.6.1.4.1.318.1.1.25.3.4.1.8 | ColumnuioOutputRelayConfigHold | read-write | mandatory | The minimum time the output relay remains activated after the alarm occurs. Valid values are whole seconds from 0 to 65535. |
| 1.3.6.1.4.1.318.1.1.26 | NoderPDU2 | |||
| 1.3.6.1.4.1.318.1.1.26.1 | ScalarrPDU2IdentTableSize | read-only | mandatory | The total number of Rack PDUs |
| 1.3.6.1.4.1.318.1.1.26.2 | TablerPDU2IdentTable | not-accessible | mandatory | A table of Rack PDU identification data |
| 1.3.6.1.4.1.318.1.1.26.2.1 | RowrPDU2IdentEntry | not-accessible | mandatory | Identification data from Rack PDU being queried |
| 1.3.6.1.4.1.318.1.1.26.2.1.1 | ColumnrPDU2IdentIndex | read-only | mandatory | The index to the Rack PDU identification table entry |
| 1.3.6.1.4.1.318.1.1.26.2.1.2 | ColumnrPDU2IdentModule | read-only | mandatory | The user-defined Rack PDU numeric ID |
| 1.3.6.1.4.1.318.1.1.26.2.1.3 | ColumnrPDU2IdentName | read-only | mandatory | A user-defined string identifying the Rack PDU |
| 1.3.6.1.4.1.318.1.1.26.2.1.4 | ColumnrPDU2IdentLocation | read-only | mandatory | A user-defined string identifying the location of the Rack PDU |
| 1.3.6.1.4.1.318.1.1.26.2.1.5 | ColumnrPDU2IdentHardwareRev | read-only | mandatory | The Rack PDU hardware version |
| 1.3.6.1.4.1.318.1.1.26.2.1.6 | ColumnrPDU2IdentFirmwareRev | read-only | mandatory | The Rack PDU firmware version |
| 1.3.6.1.4.1.318.1.1.26.2.1.7 | ColumnrPDU2IdentDateOfManufacture | read-only | mandatory | The date the Rack PDU was manufactured in mm/dd/yyyy format |
| 1.3.6.1.4.1.318.1.1.26.2.1.8 | ColumnrPDU2IdentModelNumber | read-only | mandatory | The Rack PDU model number |
| 1.3.6.1.4.1.318.1.1.26.2.1.9 | ColumnrPDU2IdentSerialNumber | read-only | mandatory | The Rack PDU serial number |
| 1.3.6.1.4.1.318.1.1.26.2.1.10 | ColumnrPDU2IdentContact | read-only | mandatory | A user-defined string identifying the person to contact regarding the Rack PDU |
| 1.3.6.1.4.1.318.1.1.26.2.1.11 | ColumnrPDU2IdentBootMonitorRev | read-only | mandatory | The Rack PDU Boot Monitor version |
| 1.3.6.1.4.1.318.1.1.26.2.1.12 | ColumnrPDU2IdentLongDescription | read-only | mandatory | The Rack PDU Long Description name |
| 1.3.6.1.4.1.318.1.1.26.2.1.13 | ColumnrPDU2IdentNMCSerialNumber | read-only | mandatory | The Rack PDU Network Management Card (NMC) serial number |
| 1.3.6.1.4.1.318.1.1.26.3 | ScalarrPDU2DeviceTableSize | read-only | mandatory | The total number of Rack PDUs |
| 1.3.6.1.4.1.318.1.1.26.4 | NoderPDU2Device | |||
| 1.3.6.1.4.1.318.1.1.26.4.1 | TablerPDU2DeviceConfigTable | not-accessible | mandatory | A table of Rack PDU configuration data |
| 1.3.6.1.4.1.318.1.1.26.4.1.1 | RowrPDU2DeviceConfigEntry | not-accessible | mandatory | Configuration data from Rack PDU being queried |
| 1.3.6.1.4.1.318.1.1.26.4.1.1.1 | ColumnrPDU2DeviceConfigIndex | read-only | mandatory | The index to the Rack PDU table entry |
| 1.3.6.1.4.1.318.1.1.26.4.1.1.2 | ColumnrPDU2DeviceConfigModule | read-write | mandatory | The user-defined Rack PDU numeric ID |
| 1.3.6.1.4.1.318.1.1.26.4.1.1.3 | ColumnrPDU2DeviceConfigName | read-write | mandatory | A user-defined string identifying the Rack PDU |
| 1.3.6.1.4.1.318.1.1.26.4.1.1.4 | ColumnrPDU2DeviceConfigLocation | read-write | mandatory | A user-defined string identifying the location of the Rack PDU |
| 1.3.6.1.4.1.318.1.1.26.4.1.1.5 | ColumnrPDU2DeviceConfigDisplayOrientation | read-write | mandatory | Indicates the intended physical orientation of the display. displayNormal(1) indicates normal orientation displayReverse(2) indicates upside down orientation |
| 1.3.6.1.4.1.318.1.1.26.4.1.1.6 | ColumnrPDU2DeviceConfigColdstartDelay | read-write | mandatory | The amount of delay, measured in seconds, between when power is provided to the Rack PDU and when the Rack PDU provides basic master power to the outlets. Allo… |
| 1.3.6.1.4.1.318.1.1.26.4.1.1.7 | ColumnrPDU2DeviceConfigLowLoadPowerThreshold | read-write | mandatory | User-defined low power draw alarm threshold, measured in tenths of kilowatts. Models that do not support this feature will respond to this OID with a value of … |
| 1.3.6.1.4.1.318.1.1.26.4.1.1.8 | ColumnrPDU2DeviceConfigNearOverloadPowerThreshold | read-write | mandatory | User-defined near power overload threshold, measured in tenths of kilowatts. Models that do not support this feature will respond to this OID with a value of -… |
| 1.3.6.1.4.1.318.1.1.26.4.1.1.9 | ColumnrPDU2DeviceConfigOverloadPowerThreshold | read-write | mandatory | User-defined power overload threshold, measured in tenths of kilowatts. Models that do not support this feature will respond to this OID with a value of -1. |
| 1.3.6.1.4.1.318.1.1.26.4.1.1.10 | ColumnrPDU2DeviceConfigDevicePeakPowerReset | read-write | mandatory | Setting this OID to reset (2) will cause the existing peak power value to be replaced by the current load power value. Getting this OID will do nothing and ret… |
| 1.3.6.1.4.1.318.1.1.26.4.1.1.11 | ColumnrPDU2DeviceConfigDeviceEnergyReset | read-write | mandatory | Setting this OID to reset (2) will cause the device energy meter value to be reset to zero. Getting this OID in models that support this feature will do nothin… |
| 1.3.6.1.4.1.318.1.1.26.4.1.1.12 | ColumnrPDU2DeviceConfigOutletsEnergyReset | read-write | mandatory | Setting this OID to reset (2) will cause the all outlet energy meter values to be reset to zero. Getting this OID will do nothing and return the noOperation(1)… |
| 1.3.6.1.4.1.318.1.1.26.4.1.1.13 | ColumnrPDU2DeviceConfigOutletsPeakLoadReset | read-write | mandatory | Setting this OID to reset (2) will cause the all outlet peak load values to be reset to zero. Getting this OID will do nothing and return the noOperation(1) va… |
| 1.3.6.1.4.1.318.1.1.26.4.1.1.14 | ColumnrPDU2DeviceConfigContact | read-write | mandatory | A user-defined string identifying the person to contact regarding the Rack PDU |
| 1.3.6.1.4.1.318.1.1.26.4.2 | TablerPDU2DevicePropertiesTable | not-accessible | mandatory | A table of Rack PDU properties |
| 1.3.6.1.4.1.318.1.1.26.4.2.1 | RowrPDU2DevicePropertiesEntry | not-accessible | mandatory | Properties of the Rack PDU being queried |
| 1.3.6.1.4.1.318.1.1.26.4.2.1.1 | ColumnrPDU2DevicePropertiesIndex | read-only | mandatory | The index to the Rack PDU properties table entry |
| 1.3.6.1.4.1.318.1.1.26.4.2.1.2 | ColumnrPDU2DevicePropertiesModule | read-only | mandatory | The user-defined Rack PDU numeric ID |
| 1.3.6.1.4.1.318.1.1.26.4.2.1.3 | ColumnrPDU2DevicePropertiesName | read-only | mandatory | A user-defined string identifying the Rack PDU |
| 1.3.6.1.4.1.318.1.1.26.4.2.1.4 | ColumnrPDU2DevicePropertiesNumOutlets | read-only | mandatory | The number of outlets on the Rack PDU |
| 1.3.6.1.4.1.318.1.1.26.4.2.1.5 | ColumnrPDU2DevicePropertiesNumSwitchedOutlets | read-only | mandatory | The number of switched outlets on the Rack PDU |
| 1.3.6.1.4.1.318.1.1.26.4.2.1.6 | ColumnrPDU2DevicePropertiesNumMeteredOutlets | read-only | mandatory | The number of metered outlets on the Rack PDU |
| 1.3.6.1.4.1.318.1.1.26.4.2.1.7 | ColumnrPDU2DevicePropertiesNumPhases | read-only | mandatory | The number of phases present in the Rack PDU |
| 1.3.6.1.4.1.318.1.1.26.4.2.1.8 | ColumnrPDU2DevicePropertiesNumMeteredBanks | read-only | mandatory | The number of metered banks present in the Rack PDU |
| 1.3.6.1.4.1.318.1.1.26.4.2.1.9 | ColumnrPDU2DevicePropertiesMaxCurrentRating | read-only | mandatory | The maximum current rating, measured in Amps, for the Rack PDU |
| 1.3.6.1.4.1.318.1.1.26.4.2.1.10 | ColumnrPDU2DevicePropertiesOrientation | read-only | mandatory | Rack PDU orientation |
| 1.3.6.1.4.1.318.1.1.26.4.2.1.11 | ColumnrPDU2DevicePropertiesOutletLayout | read-only | mandatory | Getting this OID will return outlet layout for the device. seqPhaseToNeutral(1) indicates outlet layout as follows: 1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,... or for si… |
| 1.3.6.1.4.1.318.1.1.26.4.2.1.12 | ColumnrPDU2DevicePropertiesMaxPhaseCurrentRating | read-only | mandatory | The maximum current rating, measured in Amps, for the Rack PDU |
| 1.3.6.1.4.1.318.1.1.26.4.2.1.13 | ColumnrPDU2DevicePropertiesDevicePowerRating | read-only | mandatory | The maximum power rating, measured in Watts, for the Rack PDU |
| 1.3.6.1.4.1.318.1.1.26.4.3 | TablerPDU2DeviceStatusTable | not-accessible | mandatory | A table of Rack PDU status information |
| 1.3.6.1.4.1.318.1.1.26.4.3.1 | RowrPDU2DeviceStatusEntry | not-accessible | mandatory | Status information from the Rack PDU being queried |
| 1.3.6.1.4.1.318.1.1.26.4.3.1.1 | ColumnrPDU2DeviceStatusIndex | read-only | mandatory | The index to the Rack PDU status table entry |
| 1.3.6.1.4.1.318.1.1.26.4.3.1.2 | ColumnrPDU2DeviceStatusModule | read-only | mandatory | The user-defined Rack PDU numeric ID |
| 1.3.6.1.4.1.318.1.1.26.4.3.1.3 | ColumnrPDU2DeviceStatusName | read-only | mandatory | A user-defined string identifying the Rack PDU |
| 1.3.6.1.4.1.318.1.1.26.4.3.1.4 | ColumnrPDU2DeviceStatusLoadState | read-only | mandatory | Indicates the present load status of the Rack PDU. Models that do not support this feature will respond to this OID with a value of notsupported (5). |
| 1.3.6.1.4.1.318.1.1.26.4.3.1.5 | ColumnrPDU2DeviceStatusPower | read-only | mandatory | The power consumption of the Rack PDU load in hundredths of kilowatts. Models that do not support this feature will respond to this OID with a value of -1. |
| 1.3.6.1.4.1.318.1.1.26.4.3.1.6 | ColumnrPDU2DeviceStatusPeakPower | read-only | mandatory | The peak power consumption of the Rack PDU load in hundredths of kilowatts. Models that do not support this feature will respond to this OID with a value of -1. |
| 1.3.6.1.4.1.318.1.1.26.4.3.1.7 | ColumnrPDU2DeviceStatusPeakPowerTimestamp | read-only | mandatory | Indicates the date and time that peak power consumption occurred. Models that do not support this feature will respond to this OID with string 'notsupported'. |
| 1.3.6.1.4.1.318.1.1.26.4.3.1.8 | ColumnrPDU2DeviceStatusPeakPowerStartTime | read-only | mandatory | Indicates the date and time of the last device peak power reset. Models that do not support this feature will respond to this OID with string 'notsupported'. |
| 1.3.6.1.4.1.318.1.1.26.4.3.1.9 | ColumnrPDU2DeviceStatusEnergy | read-only | mandatory | A user resettable energy meter measuring Rack PDU load energy consumption in tenths of kilowatt-hours. Models that do not support this feature will respond to … |
| 1.3.6.1.4.1.318.1.1.26.4.3.1.10 | ColumnrPDU2DeviceStatusEnergyStartTime | read-only | mandatory | Indicates the date and time of the last device energy meter reset. Models that do not support this feature will respond to this OID with string 'notsupported'. |
| 1.3.6.1.4.1.318.1.1.26.4.3.1.11 | ColumnrPDU2DeviceStatusCommandPending | read-only | mandatory | Indicates whether or not the device is processing a pending command. If the commandPendingUnknown (3) value is returned, all devices powered by the Rack PDU sh… |
| 1.3.6.1.4.1.318.1.1.26.4.3.1.12 | ColumnrPDU2DeviceStatusPowerSupplyAlarm | read-only | mandatory | Indicates a power supply alarm is active when value equals alarm (2) |
| 1.3.6.1.4.1.318.1.1.26.4.3.1.13 | ColumnrPDU2DeviceStatusPowerSupply1Status | read-only | mandatory | Indicates whether or not an alarm is active in Power Supply 1 |
| 1.3.6.1.4.1.318.1.1.26.4.3.1.14 | ColumnrPDU2DeviceStatusPowerSupply2Status | read-only | mandatory | Indicates whether or not an alarm is active in Power Supply 2 |
| 1.3.6.1.4.1.318.1.1.26.4.3.1.15 | ColumnrPDU2DeviceStatusOutletsEnergyStartTime | read-only | mandatory | Indicates the date and time of the last outlets energy meter reset. Models that do not support this feature will respond to this OID with string 'notsupported'. |
| 1.3.6.1.4.1.318.1.1.26.4.3.1.16 | ColumnrPDU2DeviceStatusApparentPower | read-only | mandatory | The apparent power consumption of the Rack PDU load in hundredths of kiloVoltAmps (kVA). Models that do not support this feature will respond to this OID with … |
| 1.3.6.1.4.1.318.1.1.26.4.3.1.17 | ColumnrPDU2DeviceStatusPowerFactor | read-only | mandatory | The power factor of the Rack PDU load in hundredths. Models that do not support this feature will respond to this OID with a value of -1. |
| 1.3.6.1.4.1.318.1.1.26.4.3.1.18 | ColumnrPDU2DeviceStatusNPSType | read-only | mandatory | The device NPS status: notNPS (1) indicates the Rack PDU is not in an NPS group. host (2) indicates the Rack PDU has been designated as a host in an NPS group.… |
| 1.3.6.1.4.1.318.1.1.26.4.4 | TablerPDU2DeviceControlTable | not-accessible | mandatory | A table of Rack PDU control data |
| 1.3.6.1.4.1.318.1.1.26.4.4.1 | RowrPDU2DeviceControlEntry | not-accessible | mandatory | Control data from Rack PDU being queried |
| 1.3.6.1.4.1.318.1.1.26.4.4.1.1 | ColumnrPDU2DeviceControlIndex | read-only | mandatory | The index to the Rack PDU control table entry |
| 1.3.6.1.4.1.318.1.1.26.4.4.1.2 | ColumnrPDU2DeviceControlModule | read-only | mandatory | The user-defined Rack PDU numeric ID |
| 1.3.6.1.4.1.318.1.1.26.4.4.1.3 | ColumnrPDU2DeviceControlName | read-only | mandatory | A user-defined string identifying the Rack PDU |
| 1.3.6.1.4.1.318.1.1.26.4.4.1.4 | ColumnrPDU2DeviceControlCommand | read-write | mandatory | Setting this OID to immediateAllOn (1) will turn all outlets on immediately. Setting this OID to delayedAllOn (2) will turn all outlets on as defined by each o… |
| 1.3.6.1.4.1.318.1.1.26.5 | ScalarrPDU2PhaseTableSize | read-only | mandatory | The number of connected Rack PDU phases |
| 1.3.6.1.4.1.318.1.1.26.6 | NoderPDU2Phase | |||
| 1.3.6.1.4.1.318.1.1.26.6.1 | TablerPDU2PhaseConfigTable | not-accessible | mandatory | A table of Rack PDU phase configuration data |
| 1.3.6.1.4.1.318.1.1.26.6.1.1 | RowrPDU2PhaseConfigEntry | not-accessible | mandatory | Configuration data from currently queried Rack PDU phase |
| 1.3.6.1.4.1.318.1.1.26.6.1.1.1 | ColumnrPDU2PhaseConfigIndex | read-only | mandatory | The index to the Rack PDU phase configuration table entry |
| 1.3.6.1.4.1.318.1.1.26.6.1.1.2 | ColumnrPDU2PhaseConfigModule | read-only | mandatory | The user-defined Rack PDU numeric ID |
| 1.3.6.1.4.1.318.1.1.26.6.1.1.3 | ColumnrPDU2PhaseConfigNumber | read-only | mandatory | The numeric phase ID |
| 1.3.6.1.4.1.318.1.1.26.6.1.1.4 | ColumnrPDU2PhaseConfigOverloadRestriction | read-write | mandatory | This OID controls the behavior of a Switched Rack PDU phase when an overload condition is possible and additional outlets are requested to be turned on. Settin… |
| 1.3.6.1.4.1.318.1.1.26.6.1.1.5 | ColumnrPDU2PhaseConfigLowLoadCurrentThreshold | read-write | mandatory | User-defined low load phase current threshold in Amps |
| 1.3.6.1.4.1.318.1.1.26.6.1.1.6 | ColumnrPDU2PhaseConfigNearOverloadCurrentThreshold | read-write | mandatory | User-defined near phase overload warning threshold in Amps |
| 1.3.6.1.4.1.318.1.1.26.6.1.1.7 | ColumnrPDU2PhaseConfigOverloadCurrentThreshold | read-write | mandatory | User-defined phase overload current threshold in Amps |
| 1.3.6.1.4.1.318.1.1.26.6.1.1.8 | ColumnrPDU2PhaseConfigPhasePeakCurrentReset | read-write | mandatory | Setting this OID to reset (2) will cause the existing peak current value to be replaced by the present load current value. Getting this OID will do nothing and… |
| 1.3.6.1.4.1.318.1.1.26.6.2 | TablerPDU2PhasePropertiesTable | not-accessible | mandatory | A table of Rack PDU phase properties |
| 1.3.6.1.4.1.318.1.1.26.6.2.1 | RowrPDU2PhasePropertiesEntry | not-accessible | mandatory | Properties of the currently queried Rack PDU phase |
| 1.3.6.1.4.1.318.1.1.26.6.2.1.1 | ColumnrPDU2PhasePropertiesIndex | read-only | mandatory | The index to the Rack PDU phase properties table entry |
| 1.3.6.1.4.1.318.1.1.26.6.2.1.2 | ColumnrPDU2PhasePropertiesModule | read-only | mandatory | The user-defined Rack PDU numeric ID |
| 1.3.6.1.4.1.318.1.1.26.6.2.1.3 | ColumnrPDU2PhasePropertiesNumber | read-only | mandatory | The numeric phase ID |
| 1.3.6.1.4.1.318.1.1.26.6.3 | TablerPDU2PhaseStatusTable | not-accessible | mandatory | A table of Rack PDU phase status data |
| 1.3.6.1.4.1.318.1.1.26.6.3.1 | RowrPDU2PhaseStatusEntry | not-accessible | mandatory | Status data from currently queried Rack PDU phase |
| 1.3.6.1.4.1.318.1.1.26.6.3.1.1 | ColumnrPDU2PhaseStatusIndex | read-only | mandatory | The index to the Rack PDU phase status table entry |
| 1.3.6.1.4.1.318.1.1.26.6.3.1.2 | ColumnrPDU2PhaseStatusModule | read-only | mandatory | The user-defined Rack PDU numeric ID |
| 1.3.6.1.4.1.318.1.1.26.6.3.1.3 | ColumnrPDU2PhaseStatusNumber | read-only | mandatory | The numeric phase ID |
| 1.3.6.1.4.1.318.1.1.26.6.3.1.4 | ColumnrPDU2PhaseStatusLoadState | read-only | mandatory | Indicates the present load status of the Rack PDU phase being queried |
| 1.3.6.1.4.1.318.1.1.26.6.3.1.5 | ColumnrPDU2PhaseStatusCurrent | read-only | mandatory | Indicates the current draw, in tenths of Amps, of the load on the Rack PDU phase being queried |
| 1.3.6.1.4.1.318.1.1.26.6.3.1.6 | ColumnrPDU2PhaseStatusVoltage | read-only | mandatory | Indicates the Voltage, in Volts, of the Rack PDU phase being queried. Models that do not support this feature will respond to this OID with a value of -1. |
| 1.3.6.1.4.1.318.1.1.26.6.3.1.7 | ColumnrPDU2PhaseStatusPower | read-only | mandatory | Indicates the load power, in hundredths of kilowatts (kW), consumed on the Rack PDU phase being queried. Models that do not support this feature will respond t… |
| 1.3.6.1.4.1.318.1.1.26.6.3.1.8 | ColumnrPDU2PhaseStatusApparentPower | read-only | mandatory | Indicates the load apparent power, in hundredths of kiloVoltAmps (kVA), consumed on the Rack PDU phase being queried. Models that do not support this feature w… |
| 1.3.6.1.4.1.318.1.1.26.6.3.1.9 | ColumnrPDU2PhaseStatusPowerFactor | read-only | mandatory | Indicates the load power factor, in hundredths, of the Rack PDU phase being queried. Models that do not support this feature will respond to this OID with a va… |
| 1.3.6.1.4.1.318.1.1.26.6.3.1.10 | ColumnrPDU2PhaseStatusPeakCurrent | read-only | mandatory | The peak current of the Rack PDU phase load in tenths of Amps |
| 1.3.6.1.4.1.318.1.1.26.6.3.1.11 | ColumnrPDU2PhaseStatusPeakCurrentTimestamp | read-only | mandatory | Indicates the date and time that the peak current occurred |
| 1.3.6.1.4.1.318.1.1.26.6.3.1.12 | ColumnrPDU2PhaseStatusPeakCurrentStartTime | read-only | mandatory | Indicates the date and time of the last phase peak current reset |
| 1.3.6.1.4.1.318.1.1.26.7 | ScalarrPDU2BankTableSize | read-only | mandatory | The number of connected Rack PDU banks |
| 1.3.6.1.4.1.318.1.1.26.8 | NoderPDU2Bank | |||
| 1.3.6.1.4.1.318.1.1.26.8.1 | TablerPDU2BankConfigTable | not-accessible | mandatory | A table of Rack PDU bank configuration data |
| 1.3.6.1.4.1.318.1.1.26.8.1.1 | RowrPDU2BankConfigEntry | not-accessible | mandatory | Configuration data from currently queried Rack PDU bank |
| 1.3.6.1.4.1.318.1.1.26.8.1.1.1 | ColumnrPDU2BankConfigIndex | read-only | mandatory | The index to the Rack PDU bank configuration table entry |
| 1.3.6.1.4.1.318.1.1.26.8.1.1.2 | ColumnrPDU2BankConfigModule | read-only | mandatory | The user-defined Rack PDU numeric ID |
| 1.3.6.1.4.1.318.1.1.26.8.1.1.3 | ColumnrPDU2BankConfigNumber | read-only | mandatory | The numeric bank ID |
| 1.3.6.1.4.1.318.1.1.26.8.1.1.4 | ColumnrPDU2BankConfigOverloadRestriction | read-write | mandatory | This OID controls the behavior of a Switched Rack PDU bank when an overload condition is possible and additional outlets are requested to be turned on. Setting… |
| 1.3.6.1.4.1.318.1.1.26.8.1.1.5 | ColumnrPDU2BankConfigLowLoadCurrentThreshold | read-write | mandatory | User-defined low load bank current threshold in Amps |
| 1.3.6.1.4.1.318.1.1.26.8.1.1.6 | ColumnrPDU2BankConfigNearOverloadCurrentThreshold | read-write | mandatory | User-defined near bank overload current warning threshold in Amps |
| 1.3.6.1.4.1.318.1.1.26.8.1.1.7 | ColumnrPDU2BankConfigOverloadCurrentThreshold | read-write | mandatory | User-defined bank overload current threshold in Amps |
| 1.3.6.1.4.1.318.1.1.26.8.1.1.8 | ColumnrPDU2BankConfigBankPeakCurrentReset | read-write | mandatory | Setting this OID to reset (2) will cause the existing peak current value to be replaced by the present load current value. Getting this OID will do nothing and… |
| 1.3.6.1.4.1.318.1.1.26.8.2 | TablerPDU2BankPropertiesTable | not-accessible | mandatory | A table of Rack PDU bank properties |
| 1.3.6.1.4.1.318.1.1.26.8.2.1 | RowrPDU2BankPropertiesEntry | not-accessible | mandatory | Properties of the currently queried Rack PDU bank |
| 1.3.6.1.4.1.318.1.1.26.8.2.1.1 | ColumnrPDU2BankPropertiesIndex | read-only | mandatory | The index to the Rack PDU bank properties table entry |
| 1.3.6.1.4.1.318.1.1.26.8.2.1.2 | ColumnrPDU2BankPropertiesModule | read-only | mandatory | The user-defined Rack PDU numeric ID |
| 1.3.6.1.4.1.318.1.1.26.8.2.1.3 | ColumnrPDU2BankPropertiesNumber | read-only | mandatory | The numeric bank ID |
| 1.3.6.1.4.1.318.1.1.26.8.2.1.4 | ColumnrPDU2BankPropertiesPhaseLayout | read-only | mandatory | This OID describes the outlet phase connections on the referenced bank as follows: seqPhase1ToNeutral(1) indicates that bank outlets are wired from Phase 1 to … |
| 1.3.6.1.4.1.318.1.1.26.8.2.1.5 | ColumnrPDU2BankPropertiesBreakerRating | read-only | mandatory | If bank circuit breakers are present on the device, this OID will return the rating of the breaker in Amps. |
| 1.3.6.1.4.1.318.1.1.26.8.3 | TablerPDU2BankStatusTable | not-accessible | mandatory | A table of Rack PDU bank status data |
| 1.3.6.1.4.1.318.1.1.26.8.3.1 | RowrPDU2BankStatusEntry | not-accessible | mandatory | Status data from currently queried Rack PDU bank |
| 1.3.6.1.4.1.318.1.1.26.8.3.1.1 | ColumnrPDU2BankStatusIndex | read-only | mandatory | The index to the Rack PDU bank status table entry |
| 1.3.6.1.4.1.318.1.1.26.8.3.1.2 | ColumnrPDU2BankStatusModule | read-only | mandatory | The user-defined Rack PDU numeric ID |
| 1.3.6.1.4.1.318.1.1.26.8.3.1.3 | ColumnrPDU2BankStatusNumber | read-only | mandatory | The numeric bank ID |
| 1.3.6.1.4.1.318.1.1.26.8.3.1.4 | ColumnrPDU2BankStatusLoadState | read-only | mandatory | Indicates the present load status of the Rack PDU bank being queried |
| 1.3.6.1.4.1.318.1.1.26.8.3.1.5 | ColumnrPDU2BankStatusCurrent | read-only | mandatory | Indicates the current draw, in tenths of Amps, of the load on the Rack PDU bank being queried |
| 1.3.6.1.4.1.318.1.1.26.8.3.1.6 | ColumnrPDU2BankStatusPeakCurrent | read-only | mandatory | The peak current of the Rack PDU bank load in tenths of Amps |
| 1.3.6.1.4.1.318.1.1.26.8.3.1.7 | ColumnrPDU2BankStatusPeakCurrentTimestamp | read-only | mandatory | Indicates the date and time the bank peak current occurred |
| 1.3.6.1.4.1.318.1.1.26.8.3.1.8 | ColumnrPDU2BankStatusPeakCurrentStartTime | read-only | mandatory | Indicates the date and time of the last bank peak current reset |
| 1.3.6.1.4.1.318.1.1.26.9 | NoderPDU2Outlet | |||
| 1.3.6.1.4.1.318.1.1.26.9.1 | ScalarrPDU2OutletSwitchedTableSize | read-only | mandatory | The number of switched outlets on connected Rack PDUs |
| 1.3.6.1.4.1.318.1.1.26.9.2 | NoderPDU2OutletSwitched | |||
| 1.3.6.1.4.1.318.1.1.26.9.2.1 | TablerPDU2OutletSwitchedConfigTable | not-accessible | mandatory | A table of Rack PDU switched outlet configuration data |
| 1.3.6.1.4.1.318.1.1.26.9.2.1.1 | RowrPDU2OutletSwitchedConfigEntry | not-accessible | mandatory | Configuration data from currently queried Rack PDU switched outlet |
| 1.3.6.1.4.1.318.1.1.26.9.2.1.1.1 | ColumnrPDU2OutletSwitchedConfigIndex | read-only | mandatory | The index to the Rack PDU switched outlet configuration table entry |
| 1.3.6.1.4.1.318.1.1.26.9.2.1.1.2 | ColumnrPDU2OutletSwitchedConfigModule | read-only | mandatory | The user-defined Rack PDU numeric ID |
| 1.3.6.1.4.1.318.1.1.26.9.2.1.1.3 | ColumnrPDU2OutletSwitchedConfigName | read-write | mandatory | The user-defined switched outlet ID string |
| 1.3.6.1.4.1.318.1.1.26.9.2.1.1.4 | ColumnrPDU2OutletSwitchedConfigNumber | read-only | mandatory | The numeric switched outlet ID |
| 1.3.6.1.4.1.318.1.1.26.9.2.1.1.5 | ColumnrPDU2OutletSwitchedConfigPowerOnTime | read-write | mandatory | The amount of delay, in seconds, between when power is provided to the Rack PDU and when this switched outlet starts providing power. Range -1...300 where -1 =… |
| 1.3.6.1.4.1.318.1.1.26.9.2.1.1.6 | ColumnrPDU2OutletSwitchedConfigPowerOffTime | read-write | mandatory | The amount of time, in seconds, this outlet will delay powering off. Range -1...300 where -1 = Never power off, 0 = immediate power off, and 1-300 = seconds to… |
| 1.3.6.1.4.1.318.1.1.26.9.2.1.1.7 | ColumnrPDU2OutletSwitchedConfigRebootDuration | read-write | mandatory | After turning power off during a reboot sequence, the amount of time to wait before turning power to this outlet back on. Range 5-60 seconds delay. |
| 1.3.6.1.4.1.318.1.1.26.9.2.1.1.8 | ColumnrPDU2OutletSwitchedConfigExternalLink | read-write | mandatory | User-defined external device web link. Possible use cases could be the IP address of the external device plugged into the outlet or its manufacturer web page f… |
| 1.3.6.1.4.1.318.1.1.26.9.2.2 | TablerPDU2OutletSwitchedPropertiesTable | not-accessible | mandatory | A table of Rack PDU switched outlet properties |
| 1.3.6.1.4.1.318.1.1.26.9.2.2.1 | RowrPDU2OutletSwitchedPropertiesEntry | not-accessible | mandatory | Properties of the currently queried Rack PDU switched outlet |
| 1.3.6.1.4.1.318.1.1.26.9.2.2.1.1 | ColumnrPDU2OutletSwitchedPropertiesIndex | read-only | mandatory | The index to the Rack PDU switched outlet properties table entry |
| 1.3.6.1.4.1.318.1.1.26.9.2.2.1.2 | ColumnrPDU2OutletSwitchedPropertiesModule | read-only | mandatory | The user-defined Rack PDU numeric ID |
| 1.3.6.1.4.1.318.1.1.26.9.2.2.1.3 | ColumnrPDU2OutletSwitchedPropertiesName | read-only | mandatory | The user-defined switched outlet ID string |
| 1.3.6.1.4.1.318.1.1.26.9.2.2.1.4 | ColumnrPDU2OutletSwitchedPropertiesNumber | read-only | mandatory | The numeric switched outlet ID |
| 1.3.6.1.4.1.318.1.1.26.9.2.2.1.5 | ColumnrPDU2OutletSwitchedPropertiesPhaseLayout | read-only | mandatory | This OID describes the phase connections of the referenced outlet as follows: seqPhase1ToNeutral(1) indicates that the outlet is wired from Phase 1 to Neutral.… |
| 1.3.6.1.4.1.318.1.1.26.9.2.2.1.6 | ColumnrPDU2OutletSwitchedPropertiesBank | read-only | mandatory | The numeric bank ID |
| 1.3.6.1.4.1.318.1.1.26.9.2.3 | TablerPDU2OutletSwitchedStatusTable | not-accessible | mandatory | A table of Rack PDU switched outlet status information |
| 1.3.6.1.4.1.318.1.1.26.9.2.3.1 | RowrPDU2OutletSwitchedStatusEntry | not-accessible | mandatory | Status information for currently queried Rack PDU switched outlet |
| 1.3.6.1.4.1.318.1.1.26.9.2.3.1.1 | ColumnrPDU2OutletSwitchedStatusIndex | read-only | mandatory | The index to the Rack PDU switched outlet status information table entry |
| 1.3.6.1.4.1.318.1.1.26.9.2.3.1.2 | ColumnrPDU2OutletSwitchedStatusModule | read-only | mandatory | The user-defined Rack PDU numeric ID |
| 1.3.6.1.4.1.318.1.1.26.9.2.3.1.3 | ColumnrPDU2OutletSwitchedStatusName | read-only | mandatory | The user-defined switched outlet ID string |
| 1.3.6.1.4.1.318.1.1.26.9.2.3.1.4 | ColumnrPDU2OutletSwitchedStatusNumber | read-only | mandatory | The numeric switched outlet ID |
| 1.3.6.1.4.1.318.1.1.26.9.2.3.1.5 | ColumnrPDU2OutletSwitchedStatusState | read-only | mandatory | Indicates the present switch state of the Rack PDU switched outlet being queried |
| 1.3.6.1.4.1.318.1.1.26.9.2.3.1.6 | ColumnrPDU2OutletSwitchedStatusCommandPending | read-only | mandatory | Indicates whether or not the device is processing a command for this outlet. If the commandPendingUnknown (3) value is returned, all devices powered by the Rac… |
| 1.3.6.1.4.1.318.1.1.26.9.2.3.1.7 | ColumnrPDU2OutletSwitchedStatusExternalLink | read-only | mandatory | Each RPDU outlet can have its own external web URL link. This can be configured in the rPDU2OutletSwitchedConfigExternalLink OID. When this link is clicked in … |
| 1.3.6.1.4.1.318.1.1.26.9.2.4 | TablerPDU2OutletSwitchedControlTable | not-accessible | mandatory | A table of Rack PDU switched outlet control data |
| 1.3.6.1.4.1.318.1.1.26.9.2.4.1 | RowrPDU2OutletSwitchedControlEntry | not-accessible | mandatory | Control data for currently queried Rack PDU switched outlet |
| 1.3.6.1.4.1.318.1.1.26.9.2.4.1.1 | ColumnrPDU2OutletSwitchedControlIndex | read-only | mandatory | The index to the Rack PDU switched outlet control data table entry |
| 1.3.6.1.4.1.318.1.1.26.9.2.4.1.2 | ColumnrPDU2OutletSwitchedControlModule | read-only | mandatory | The user-defined Rack PDU numeric ID |
| 1.3.6.1.4.1.318.1.1.26.9.2.4.1.3 | ColumnrPDU2OutletSwitchedControlName | read-only | mandatory | The user-defined switched outlet ID string |
| 1.3.6.1.4.1.318.1.1.26.9.2.4.1.4 | ColumnrPDU2OutletSwitchedControlNumber | read-only | mandatory | The numeric switched outlet ID |
| 1.3.6.1.4.1.318.1.1.26.9.2.4.1.5 | ColumnrPDU2OutletSwitchedControlCommand | read-write | mandatory | Getting this variable will return the outlet state. If the outlet is on, the immediateOn (1) value will be returned. If the outlet is off, the immediateOff (2)… |
| 1.3.6.1.4.1.318.1.1.26.9.3 | ScalarrPDU2OutletMeteredTableSize | read-only | mandatory | The number of metered outlets on connect Rack PDUs |
| 1.3.6.1.4.1.318.1.1.26.9.4 | NoderPDU2OutletMetered | |||
| 1.3.6.1.4.1.318.1.1.26.9.4.1 | TablerPDU2OutletMeteredConfigTable | not-accessible | mandatory | A table of Rack PDU metered outlet configuration data |
| 1.3.6.1.4.1.318.1.1.26.9.4.1.1 | RowrPDU2OutletMeteredConfigEntry | not-accessible | mandatory | Configuration data from currently queried Rack PDU metered outlet |
| 1.3.6.1.4.1.318.1.1.26.9.4.1.1.1 | ColumnrPDU2OutletMeteredConfigIndex | read-only | mandatory | The index to the Rack PDU metered outlet configuration table entry |
| 1.3.6.1.4.1.318.1.1.26.9.4.1.1.2 | ColumnrPDU2OutletMeteredConfigModule | read-only | mandatory | The user-defined Rack PDU numeric ID |
| 1.3.6.1.4.1.318.1.1.26.9.4.1.1.3 | ColumnrPDU2OutletMeteredConfigName | read-write | mandatory | The user-defined metered outlet ID string |
| 1.3.6.1.4.1.318.1.1.26.9.4.1.1.4 | ColumnrPDU2OutletMeteredConfigNumber | read-only | mandatory | The numeric switched outlet ID |
| 1.3.6.1.4.1.318.1.1.26.9.4.1.1.5 | ColumnrPDU2OutletMeteredConfigLowLoadCurrentThreshold | read-write | mandatory | User-defined low load outlet current threshold in Watts |
| 1.3.6.1.4.1.318.1.1.26.9.4.1.1.6 | ColumnrPDU2OutletMeteredConfigNearOverloadCurrentThreshold | read-write | mandatory | User-defined near outlet overload warning threshold in Watts |
| 1.3.6.1.4.1.318.1.1.26.9.4.1.1.7 | ColumnrPDU2OutletMeteredConfigOverloadCurrentThreshold | read-write | mandatory | User-defined outlet overload current threshold in Watts |
| 1.3.6.1.4.1.318.1.1.26.9.4.1.1.8 | ColumnrPDU2OutletMeteredConfigExternalLink | read-write | mandatory | User-defined external device web link. Possible use cases could be the IP address of the external device plugged into the outlet or its manufacturer web page f… |
| 1.3.6.1.4.1.318.1.1.26.9.4.2 | TablerPDU2OutletMeteredPropertiesTable | not-accessible | mandatory | A table of Rack PDU metered outlet properties |
| 1.3.6.1.4.1.318.1.1.26.9.4.2.1 | RowrPDU2OutletMeteredPropertiesEntry | not-accessible | mandatory | Properties of currently queried Rack PDU metered outlet |
| 1.3.6.1.4.1.318.1.1.26.9.4.2.1.1 | ColumnrPDU2OutletMeteredPropertiesIndex | read-only | mandatory | The index to the Rack PDU metered properties table entry |
| 1.3.6.1.4.1.318.1.1.26.9.4.2.1.2 | ColumnrPDU2OutletMeteredPropertiesModule | read-only | mandatory | The user-defined Rack PDU numeric ID |
| 1.3.6.1.4.1.318.1.1.26.9.4.2.1.3 | ColumnrPDU2OutletMeteredPropertiesName | read-only | mandatory | The user-defined metered outlet ID string |
| 1.3.6.1.4.1.318.1.1.26.9.4.2.1.4 | ColumnrPDU2OutletMeteredPropertiesNumber | read-only | mandatory | The numeric metered outlet ID |
| 1.3.6.1.4.1.318.1.1.26.9.4.2.1.5 | ColumnrPDU2OutletMeteredPropertiesLayout | read-only | mandatory | This OID describes the phase connections of the referenced outlet as follows: seqPhase1ToNeutral(1) indicates that the outlet is wired from Phase 1 to Neutral.… |
| 1.3.6.1.4.1.318.1.1.26.9.4.2.1.6 | ColumnrPDU2OutletMeteredPropertiesPowerRating | read-only | mandatory | Maximum power rating of Rack PDU metered outlet |
| 1.3.6.1.4.1.318.1.1.26.9.4.2.1.7 | ColumnrPDU2OutletMeteredPropertiesBank | read-only | mandatory | This outlet's numeric bank ID |
| 1.3.6.1.4.1.318.1.1.26.9.4.3 | TablerPDU2OutletMeteredStatusTable | not-accessible | mandatory | A table of Rack PDU metered outlet status data |
| 1.3.6.1.4.1.318.1.1.26.9.4.3.1 | RowrPDU2OutletMeteredStatusEntry | not-accessible | mandatory | Status data from currently queried Rack PDU metered outlet |
| 1.3.6.1.4.1.318.1.1.26.9.4.3.1.1 | ColumnrPDU2OutletMeteredStatusIndex | read-only | mandatory | The index to the Rack PDU metered status table entry |
| 1.3.6.1.4.1.318.1.1.26.9.4.3.1.2 | ColumnrPDU2OutletMeteredStatusModule | read-only | mandatory | The user-defined Rack PDU numeric ID |
| 1.3.6.1.4.1.318.1.1.26.9.4.3.1.3 | ColumnrPDU2OutletMeteredStatusName | read-only | mandatory | The user-defined metered outlet ID string |
| 1.3.6.1.4.1.318.1.1.26.9.4.3.1.4 | ColumnrPDU2OutletMeteredStatusNumber | read-only | mandatory | The numeric metered outlet ID |
| 1.3.6.1.4.1.318.1.1.26.9.4.3.1.5 | ColumnrPDU2OutletMeteredStatusState | read-only | mandatory | Indicates the present load status of the Rack PDU metered outlet being queried |
| 1.3.6.1.4.1.318.1.1.26.9.4.3.1.6 | ColumnrPDU2OutletMeteredStatusCurrent | read-only | mandatory | Indicates the current draw, in tenths of Amps, of the load on the Rack PDU outlet being queried |
| 1.3.6.1.4.1.318.1.1.26.9.4.3.1.7 | ColumnrPDU2OutletMeteredStatusPower | read-only | mandatory | Indicates the power draw of the load on the Rack PDU outlet being queried |
| 1.3.6.1.4.1.318.1.1.26.9.4.3.1.8 | ColumnrPDU2OutletMeteredStatusPeakPower | read-only | mandatory | Indicates the peak power load draw on the Rack PDU outlet being queried |
| 1.3.6.1.4.1.318.1.1.26.9.4.3.1.9 | ColumnrPDU2OutletMeteredStatusPeakPowerTimestamp | read-only | mandatory | Indicates the date and time that this metered outlet's peak power consumption occurred |
| 1.3.6.1.4.1.318.1.1.26.9.4.3.1.10 | ColumnrPDU2OutletMeteredStatusPeakPowerStartTime | read-only | mandatory | Indicates the start date and time that this metered outlet began recording peak power observations |
| 1.3.6.1.4.1.318.1.1.26.9.4.3.1.11 | ColumnrPDU2OutletMeteredStatusEnergy | read-only | mandatory | A user resettable energy meter measuring Rack PDU load energy consumption in tenths of kilowatt-hours |
| 1.3.6.1.4.1.318.1.1.26.9.4.3.1.12 | ColumnrPDU2OutletMeteredStatusReceptacleType | read-only | mandatory | Indicates receptacle type for the outlet. |
| 1.3.6.1.4.1.318.1.1.26.9.4.3.1.13 | ColumnrPDU2OutletMeteredStatusExternalLink | read-only | mandatory | Each RPDU outlet can have its own external web URL link. This can be configured in the rPDU2OutletMeteredConfigExternalLink OID. When this link is clicked in t… |
| 1.3.6.1.4.1.318.1.1.26.10 | NoderPDU2Sensor | |||
| 1.3.6.1.4.1.318.1.1.26.10.1 | ScalarrPDU2SensorTempHumidityTableSize | read-only | mandatory | The number of connected temperature-humidity sensors |
| 1.3.6.1.4.1.318.1.1.26.10.2 | NoderPDU2SensorTempHumidity | |||
| 1.3.6.1.4.1.318.1.1.26.10.2.1 | TablerPDU2SensorTempHumidityConfigTable | not-accessible | mandatory | A table of temperature-humidity sensor configuration data |
| 1.3.6.1.4.1.318.1.1.26.10.2.1.1 | RowrPDU2SensorTempHumidityConfigEntry | not-accessible | mandatory | Configuration data from temperature-humidity sensor being queried |
| 1.3.6.1.4.1.318.1.1.26.10.2.1.1.1 | ColumnrPDU2SensorTempHumidityConfigIndex | read-only | mandatory | The index to the temperature-humidity sensor configuration data table entry |
| 1.3.6.1.4.1.318.1.1.26.10.2.1.1.2 | ColumnrPDU2SensorTempHumidityConfigModule | read-only | mandatory | The user-defined Rack PDU numeric ID |
| 1.3.6.1.4.1.318.1.1.26.10.2.1.1.3 | ColumnrPDU2SensorTempHumidityConfigName | read-write | mandatory | The user-defined temperature-humidity sensor ID string |
| 1.3.6.1.4.1.318.1.1.26.10.2.1.1.4 | ColumnrPDU2SensorTempHumidityConfigNumber | read-only | mandatory | The temperature-humidity sensor numeric ID |
| 1.3.6.1.4.1.318.1.1.26.10.2.1.1.5 | ColumnrPDU2SensorTempHumidityConfigTemperatureAlarmEnable | read-write | mandatory | Setting this OID enables or disables generation of sensor temperature alarm. Getting this OID returns the current value of the temperature alarm enable. |
| 1.3.6.1.4.1.318.1.1.26.10.2.1.1.6 | ColumnrPDU2SensorTempHumidityConfigHumidityAlarmEnable | read-write | mandatory | Setting this OID enables or disables generation of sensor humidity alarm. Getting this OID returns the current value of the humidity alarm enable. |
| 1.3.6.1.4.1.318.1.1.26.10.2.1.1.7 | ColumnrPDU2SensorTempHumidityConfigTempMaxThreshF | read-write | mandatory | Sensor maximum temperature alarm threshold in Fahrenheit. Attempting to set this OID to a value less than or equal to that of rPDU2SensorTempHumidityConfigTemp… |
| 1.3.6.1.4.1.318.1.1.26.10.2.1.1.8 | ColumnrPDU2SensorTempHumidityConfigTempHighThreshF | read-write | mandatory | Sensor high temperature warning alarm threshold in Fahrenheit. Attempting to set this OID to a value greater than or equal to that of rPDU2SensorTempHumidityCo… |
| 1.3.6.1.4.1.318.1.1.26.10.2.1.1.9 | ColumnrPDU2SensorTempHumidityConfigTempHysteresisF | read-write | mandatory | Sensor temperature hysteresis setting in Fahrenheit |
| 1.3.6.1.4.1.318.1.1.26.10.2.1.1.10 | ColumnrPDU2SensorTempHumidityConfigTempMaxThreshC | read-write | mandatory | Sensor maximum temperature alarm threshold in Celsius. Attempting to set this OID to a value less than or equal to that of rPDU2SensorTempHumidityConfigTempHig… |
| 1.3.6.1.4.1.318.1.1.26.10.2.1.1.11 | ColumnrPDU2SensorTempHumidityConfigTempHighThreshC | read-write | mandatory | Sensor high temperature warning alarm threshold in Celsius. Attempting to set this OID to a value greater than or equal to that of rPDU2SensorTempHumidityConfi… |
| 1.3.6.1.4.1.318.1.1.26.10.2.1.1.12 | ColumnrPDU2SensorTempHumidityConfigTempHysteresisC | read-write | mandatory | Sensor temperature hysteresis setting in Celsius |
| 1.3.6.1.4.1.318.1.1.26.10.2.1.1.13 | ColumnrPDU2SensorTempHumidityConfigHumidityLowThresh | read-write | mandatory | Sensor low humidity warning alarm threshold in percent relative humidity. Attempting to set this OID to a value less than or equal to that of rPDU2SensorTempHu… |
| 1.3.6.1.4.1.318.1.1.26.10.2.1.1.14 | ColumnrPDU2SensorTempHumidityConfigHumidityMinThresh | read-write | mandatory | Sensor minimum humidity alarm threshold in percent relative humidity. Attempting to set this OID to a value greater than or equal to that of rPDU2SensorTempHum… |
| 1.3.6.1.4.1.318.1.1.26.10.2.1.1.15 | ColumnrPDU2SensorTempHumidityConfigHumidityHysteresis | read-write | mandatory | Sensor humidity hysteresis setting in percent relative humidity |
| 1.3.6.1.4.1.318.1.1.26.10.2.1.1.16 | ColumnrPDU2SensorTempHumidityConfigTempPeakReset | read-write | mandatory | Setting this OID to reset (2) will cause the existing peak temperature to be replaced by the present temperature reading. Getting this OID will do nothing and … |
| 1.3.6.1.4.1.318.1.1.26.10.2.2 | TablerPDU2SensorTempHumidityStatusTable | not-accessible | mandatory | A table of temperature-humidity sensor status data |
| 1.3.6.1.4.1.318.1.1.26.10.2.2.1 | RowrPDU2SensorTempHumidityStatusEntry | not-accessible | mandatory | Status information from temperature-humidity sensor being queried |
| 1.3.6.1.4.1.318.1.1.26.10.2.2.1.1 | ColumnrPDU2SensorTempHumidityStatusIndex | read-only | mandatory | The index to the temperature-humidity status data table entry |
| 1.3.6.1.4.1.318.1.1.26.10.2.2.1.2 | ColumnrPDU2SensorTempHumidityStatusModule | read-only | mandatory | The user-defined Rack PDU numeric ID |
| 1.3.6.1.4.1.318.1.1.26.10.2.2.1.3 | ColumnrPDU2SensorTempHumidityStatusName | read-only | mandatory | The user-defined temperature-humidity sensor ID string |
| 1.3.6.1.4.1.318.1.1.26.10.2.2.1.4 | ColumnrPDU2SensorTempHumidityStatusNumber | read-only | mandatory | The temperature-humidity sensor numeric ID |
| 1.3.6.1.4.1.318.1.1.26.10.2.2.1.5 | ColumnrPDU2SensorTempHumidityStatusType | read-only | mandatory | The type of the sensor |
| 1.3.6.1.4.1.318.1.1.26.10.2.2.1.6 | ColumnrPDU2SensorTempHumidityStatusCommStatus | read-only | mandatory | The communications status of the sensor |
| 1.3.6.1.4.1.318.1.1.26.10.2.2.1.7 | ColumnrPDU2SensorTempHumidityStatusTempF | read-only | mandatory | Sensor temperature reading in tenths of degrees Fahrenheit |
| 1.3.6.1.4.1.318.1.1.26.10.2.2.1.8 | ColumnrPDU2SensorTempHumidityStatusTempC | read-only | mandatory | Sensor temperature reading in tenths of degrees Celsius |
| 1.3.6.1.4.1.318.1.1.26.10.2.2.1.9 | ColumnrPDU2SensorTempHumidityStatusTempStatus | read-only | mandatory | This OID reports the current state of the temperature probe. A notPresent (1) response indicates that no probe is attached. A belowMin (2) response indicates t… |
| 1.3.6.1.4.1.318.1.1.26.10.2.2.1.10 | ColumnrPDU2SensorTempHumidityStatusRelativeHumidity | read-only | mandatory | Sensor humidity reading in percent relative humidity |
| 1.3.6.1.4.1.318.1.1.26.10.2.2.1.11 | ColumnrPDU2SensorTempHumidityStatusHumidityStatus | read-only | mandatory | This OID reports the current state of the humidity probe. A notPresent (1) response indicates that no probe is attached. A belowMin (2) response indicates that… |
| 1.3.6.1.4.1.318.1.1.26.10.2.2.1.12 | ColumnrPDU2SensorTempHumidityStatusTempPeakF | read-only | mandatory | Sensor peak temperature in tenths of degrees Fahrenheit |
| 1.3.6.1.4.1.318.1.1.26.10.2.2.1.13 | ColumnrPDU2SensorTempHumidityStatusTempPeakC | read-only | mandatory | Sensor peak temperature in tenths of degrees Celsius |
| 1.3.6.1.4.1.318.1.1.26.10.2.2.1.14 | ColumnrPDU2SensorTempHumidityStatusTempPeakTimestamp | read-only | mandatory | Indicates the date and time that the peak temperature occurred |
| 1.3.6.1.4.1.318.1.1.26.10.2.2.1.15 | ColumnrPDU2SensorTempHumidityStatusTempPeakStartTime | read-only | mandatory | Indicates the date and time of the last temperature peak reset |
| 1.3.6.1.4.1.318.1.1.26.10.3 | ScalarrPDU2SensorDiscreteTableSize | read-only | mandatory | The number of connected discrete sensors |
| 1.3.6.1.4.1.318.1.1.26.10.4 | NoderPDU2SensorDiscrete | |||
| 1.3.6.1.4.1.318.1.1.26.10.4.1 | TablerPDU2SensorDiscreteConfigTable | not-accessible | mandatory | A table of discrete sensor configuration data |
| 1.3.6.1.4.1.318.1.1.26.10.4.1.1 | RowrPDU2SensorDiscreteConfigEntry | not-accessible | mandatory | Configuration data from discreste sensor being queried |
| 1.3.6.1.4.1.318.1.1.26.10.4.1.1.1 | ColumnrPDU2SensorDiscreteConfigIndex | read-only | mandatory | The index to the discrete sensor configuration data table entry |
| 1.3.6.1.4.1.318.1.1.26.10.4.1.1.2 | ColumnrPDU2SensorDiscreteConfigModule | read-only | mandatory | The user-defined Rack PDU numeric ID |
| 1.3.6.1.4.1.318.1.1.26.10.4.1.1.3 | ColumnrPDU2SensorDiscreteConfigName | read-write | mandatory | The user-defined discrete sensor ID string |
| 1.3.6.1.4.1.318.1.1.26.10.4.1.1.4 | ColumnrPDU2SensorDiscreteConfigNumber | read-only | mandatory | The discrete sensor numeric ID |
| 1.3.6.1.4.1.318.1.1.26.10.4.1.1.5 | ColumnrPDU2SensorDiscreteConfigNormalState | read-write | mandatory | Indicates the normal state of the discrete input contact |
| 1.3.6.1.4.1.318.1.1.26.10.4.1.1.6 | ColumnrPDU2SensorDiscreteConfigAbnormalSeverity | read-write | mandatory | Indicates the severity of alarm triggered by abnormal discrete input contact state |
| 1.3.6.1.4.1.318.1.1.26.10.4.2 | TablerPDU2SensorDiscreteStatusTable | not-accessible | mandatory | A table of discrete sensor status data |
| 1.3.6.1.4.1.318.1.1.26.10.4.2.1 | RowrPDU2SensorDiscreteStatusEntry | not-accessible | mandatory | Status information from discrete sensor being queried |
| 1.3.6.1.4.1.318.1.1.26.10.4.2.1.1 | ColumnrPDU2SensorDiscreteStatusIndex | read-only | mandatory | The index to the discrete sensor status data table entry |
| 1.3.6.1.4.1.318.1.1.26.10.4.2.1.2 | ColumnrPDU2SensorDiscreteStatusModule | read-only | mandatory | The user-defined Rack PDU numeric ID |
| 1.3.6.1.4.1.318.1.1.26.10.4.2.1.3 | ColumnrPDU2SensorDiscreteStatusName | read-only | mandatory | The user-defined discrete sensor ID string |
| 1.3.6.1.4.1.318.1.1.26.10.4.2.1.4 | ColumnrPDU2SensorDiscreteStatusNumber | read-only | mandatory | The discrete sensor numeric ID |
| 1.3.6.1.4.1.318.1.1.26.10.4.2.1.5 | ColumnrPDU2SensorDiscreteStatusType | read-only | mandatory | The type of discrete sensor currently being queried |
| 1.3.6.1.4.1.318.1.1.26.10.4.2.1.6 | ColumnrPDU2SensorDiscreteStatusCommStatus | read-only | mandatory | The communications status of the sensor |
| 1.3.6.1.4.1.318.1.1.26.10.4.2.1.7 | ColumnrPDU2SensorDiscreteStatusCurrentState | read-only | mandatory | The current open/close state of the discrete sensor |
| 1.3.6.1.4.1.318.1.1.26.10.4.2.1.8 | ColumnrPDU2SensorDiscreteStatusAlarmState | read-only | mandatory | Indicates alarm status of discrete sensor input |
| 1.3.6.1.4.1.318.1.1.26.11 | NoderPDU2Group | |||
| 1.3.6.1.4.1.318.1.1.26.11.1 | ScalarrPDU2GroupNumberOfDevices | read-only | mandatory | Getting this OID will return the number of Rack PDU devices contributing to the Network Port Sharing (NPS) group power and energy values. Queries to guest unit… |
| 1.3.6.1.4.1.318.1.1.26.11.2 | ScalarrPDU2GroupTotalPower | read-only | mandatory | Getting this OID will return the total power consumption of the Rack PDU Network Port Sharing (NPS) group devices in hundredths of kilowatts. Queries to guest … |
| 1.3.6.1.4.1.318.1.1.26.11.3 | ScalarrPDU2GroupTotalEnergy | read-only | mandatory | Getting this OID will return the total energy consumption of the Rack PDU Network Port Sharing (NPS) group devices in tenths of kilowatt-hours. To reset the en… |
| 1.3.6.1.4.1.318.1.1.26.11.4 | ScalarrPDU2GroupEnergyReset | read-write | mandatory | Setting this OID to reset (2) will cause the device energy meter value on each device in the Rack PDU Network Port Sharing (NPS) group to be reset to zero. Eac… |
| 1.3.6.1.4.1.318.1.1.26.12 | ScalarrPDU2PhaseToPhaseStatusTableSize | read-only | mandatory | The number of connected Rack PDU banks |
| 1.3.6.1.4.1.318.1.1.26.13 | NoderPDU2PhaseToPhase | |||
| 1.3.6.1.4.1.318.1.1.26.13.1 | TablerPDU2PhaseToPhaseStatusTable | not-accessible | mandatory | A table of Rack PDU phase to phase status data. This table is only applicable to SKUs that have phase to phase outputs. |
| 1.3.6.1.4.1.318.1.1.26.13.1.1 | RowrPDU2PhaseToPhaseStatusEntry | not-accessible | mandatory | Status data from currently queried Rack PDU phase to phase outputs |
| 1.3.6.1.4.1.318.1.1.26.13.1.1.1 | ColumnrPDU2PhaseToPhaseStatusIndex | read-only | mandatory | The index to the Rack PDU phase to phase status table entry |
| 1.3.6.1.4.1.318.1.1.26.13.1.1.2 | ColumnrPDU2PhaseToPhaseStatusModule | read-only | mandatory | The user-defined Rack PDU numeric ID |
| 1.3.6.1.4.1.318.1.1.26.13.1.1.3 | ColumnrPDU2PhaseToPhaseStatusVoltage1to2 | read-only | mandatory | Indicates the Voltage, in Volts, of the Rack PDU phase 1 to phase 2 output being queried |
| 1.3.6.1.4.1.318.1.1.26.13.1.1.4 | ColumnrPDU2PhaseToPhaseStatusVoltage2to3 | read-only | mandatory | Indicates the Voltage, in Volts, of the Rack PDU phase 2 to phase 3 output being queried |
| 1.3.6.1.4.1.318.1.1.26.13.1.1.5 | ColumnrPDU2PhaseToPhaseStatusVoltage3to1 | read-only | mandatory | Indicates the Voltage, in Volts, of the Rack PDU phase 3 to phase 2 output being queried |
| 1.3.6.1.4.1.318.1.1.27 | Nodecooling | |||
| 1.3.6.1.4.1.318.1.1.27.1 | NodecoolingUnit | |||
| 1.3.6.1.4.1.318.1.1.27.1.1 | ScalarcoolingUnitTableSize | read-only | mandatory | The number of cooling units accessible via this agent. |
| 1.3.6.1.4.1.318.1.1.27.1.2 | TablecoolingUnitTable | not-accessible | mandatory | A table of cooling unit level data. |
| 1.3.6.1.4.1.318.1.1.27.1.2.1 | RowcoolingUnitEntry | not-accessible | mandatory | An element of coolingUnitTable. |
| 1.3.6.1.4.1.318.1.1.27.1.2.1.1 | ColumncoolingUnitTableIndex | not-accessible | mandatory | The unit reference identifier for this table and all other table entries subordinate to coolingUnits. |
| 1.3.6.1.4.1.318.1.1.27.1.3 | NodecoolingUnitAbout | |||
| 1.3.6.1.4.1.318.1.1.27.1.3.1 | ScalarcoolingUnitAboutTableSize | read-only | mandatory | The potential number of entries available in coolingUnitAboutTable. |
| 1.3.6.1.4.1.318.1.1.27.1.3.2 | TablecoolingUnitAboutTable | not-accessible | mandatory | A table of unit reference information. |
| 1.3.6.1.4.1.318.1.1.27.1.3.2.1 | RowcoolingUnitAboutEntry | not-accessible | mandatory | An element of coolingUnitAboutTable. |
| 1.3.6.1.4.1.318.1.1.27.1.3.2.1.1 | ColumncoolingUnitAboutTableIndex | not-accessible | mandatory | The static reference identifier for each table entry. |
| 1.3.6.1.4.1.318.1.1.27.1.3.2.1.2 | ColumncoolingUnitAboutDescription | read-only | mandatory | A text description of the information presented in coolingUnitAboutValue. |
| 1.3.6.1.4.1.318.1.1.27.1.3.2.1.3 | ColumncoolingUnitAboutValue | read-only | mandatory | The actual value of the current table entry. |
| 1.3.6.1.4.1.318.1.1.27.1.4 | NodecoolingUnitStatus | |||
| 1.3.6.1.4.1.318.1.1.27.1.4.1 | NodecoolingUnitStatusAnalog | |||
| 1.3.6.1.4.1.318.1.1.27.1.4.1.1 | ScalarcoolingUnitStatusAnalogTableSize | read-only | mandatory | The potential number of entries available in coolingUnitStatusAnalogTable. |
| 1.3.6.1.4.1.318.1.1.27.1.4.1.2 | TablecoolingUnitStatusAnalogTable | not-accessible | mandatory | A table of analog unit status data. |
| 1.3.6.1.4.1.318.1.1.27.1.4.1.2.1 | RowcoolingUnitStatusAnalogEntry | not-accessible | mandatory | An element of coolingUnitStatusAnalogTable. |
| 1.3.6.1.4.1.318.1.1.27.1.4.1.2.1.1 | ColumncoolingUnitStatusAnalogTableIndex | not-accessible | mandatory | The static reference identifier for each table entry. |
| 1.3.6.1.4.1.318.1.1.27.1.4.1.2.1.2 | ColumncoolingUnitStatusAnalogDescription | read-only | mandatory | A text description of the information presented in coolingUnitStatusAnalogValue. |
| 1.3.6.1.4.1.318.1.1.27.1.4.1.2.1.3 | ColumncoolingUnitStatusAnalogValue | read-only | mandatory | The scaled value of the current table entry (multiplied by coolingUnitStatusAnalogScale for integer presentation). |
| 1.3.6.1.4.1.318.1.1.27.1.4.1.2.1.4 | ColumncoolingUnitStatusAnalogUnits | read-only | mandatory | The unit of measure by which coolingUnitStatusAnalogValue is expressed. |
| 1.3.6.1.4.1.318.1.1.27.1.4.1.2.1.5 | ColumncoolingUnitStatusAnalogScale | read-only | mandatory | The factor by which coolingUnitStatusAnalogValue is expressed. |
| 1.3.6.1.4.1.318.1.1.27.1.4.2 | NodecoolingUnitStatusDiscrete | |||
| 1.3.6.1.4.1.318.1.1.27.1.4.2.1 | ScalarcoolingUnitStatusDiscreteTableSize | read-only | mandatory | The potential number of entries available in coolingUnitStatusDiscreteTable. |
| 1.3.6.1.4.1.318.1.1.27.1.4.2.2 | TablecoolingUnitStatusDiscreteTable | not-accessible | mandatory | A table of discrete unit status data. |
| 1.3.6.1.4.1.318.1.1.27.1.4.2.2.1 | RowcoolingUnitStatusDiscreteEntry | not-accessible | mandatory | An element of coolingUnitStatusDiscreteTable. |
| 1.3.6.1.4.1.318.1.1.27.1.4.2.2.1.1 | ColumncoolingUnitStatusDiscreteTableIndex | not-accessible | mandatory | The static reference identifier for each table entry. |
| 1.3.6.1.4.1.318.1.1.27.1.4.2.2.1.2 | ColumncoolingUnitStatusDiscreteDescription | read-only | mandatory | A text description of the information presented in this table's 'value' OIDs. |
| 1.3.6.1.4.1.318.1.1.27.1.4.2.2.1.3 | ColumncoolingUnitStatusDiscreteValueAsString | read-only | mandatory | The actual value of the current table entry expressed as a string. |
| 1.3.6.1.4.1.318.1.1.27.1.4.2.2.1.4 | ColumncoolingUnitStatusDiscreteValueAsInteger | read-only | mandatory | The actual value of the current table entry expressed as an integer value. |
| 1.3.6.1.4.1.318.1.1.27.1.4.2.2.1.5 | ColumncoolingUnitStatusDiscreteIntegerReferenceKey | read-only | mandatory | A complete listing of all possible coolingUnitStatusDiscreteValueAsInteger values paired with their identifying strings. |
| 1.3.6.1.4.1.318.1.1.27.1.5 | NodecoolingUnitConfiguration | |||
| 1.3.6.1.4.1.318.1.1.27.1.5.1 | NodecoolingUnitConfigurationAnalog | |||
| 1.3.6.1.4.1.318.1.1.27.1.5.1.1 | ScalarcoolingUnitConfigurationAnalogTableSize | read-only | mandatory | The potential number of entries available in coolingUnitConfigurationAnalogTable. |
| 1.3.6.1.4.1.318.1.1.27.1.5.1.2 | TablecoolingUnitConfigurationAnalogTable | not-accessible | mandatory | A table of analog unit configuration data. |
| 1.3.6.1.4.1.318.1.1.27.1.5.1.2.1 | RowcoolingUnitConfigurationAnalogEntry | not-accessible | mandatory | An element of coolingUnitConfigurationAnalogTable. |
| 1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.1 | ColumncoolingUnitConfigurationAnalogTableIndex | not-accessible | mandatory | The static reference identifier for each table entry. |
| 1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.2 | ColumncoolingUnitConfigurationAnalogDescription | read-only | mandatory | A text description of the information presented in coolingUnitConfigurationAnalogValue. |
| 1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.3 | ColumncoolingUnitConfigurationAnalogValue | read-write | mandatory | The scaled value of the current table entry (multiplied by coolingUnitConfigurationAnalogScale for integer presentation). |
| 1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.4 | ColumncoolingUnitConfigurationAnalogUnits | read-only | mandatory | The unit of measure by which coolingUnitConfigurationAnalogValue is expressed. |
| 1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.5 | ColumncoolingUnitConfigurationAnalogScale | read-only | mandatory | The factor by which coolingUnitConfigurationAnalogValue is expressed. |
| 1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.6 | ColumncoolingUnitConfigurationAnalogAccess | read-only | mandatory | A description of available access to coolingUnitConfigurationAnalogValue via SNMP client. |
| 1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.7 | ColumncoolingUnitConfigurationAnalogMinimum | read-only | mandatory | The minimum possible value of coolingUnitConfigurationAnalogValue. |
| 1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.8 | ColumncoolingUnitConfigurationAnalogMaximum | read-only | mandatory | The maximum possible value of coolingUnitConfigurationAnalogValue. |
| 1.3.6.1.4.1.318.1.1.27.1.5.2 | NodecoolingUnitConfigurationDiscrete | |||
| 1.3.6.1.4.1.318.1.1.27.1.5.2.1 | ScalarcoolingUnitConfigurationDiscreteTableSize | read-only | mandatory | The potential number of entries available in coolingUnitConfigurationDiscreteTable. |
| 1.3.6.1.4.1.318.1.1.27.1.5.2.2 | TablecoolingUnitConfigurationDiscreteTable | not-accessible | mandatory | A table of discrete unit configuration data. |
| 1.3.6.1.4.1.318.1.1.27.1.5.2.2.1 | RowcoolingUnitConfigurationDiscreteEntry | not-accessible | mandatory | An element of coolingUnitConfigurationDiscreteTable. |
| 1.3.6.1.4.1.318.1.1.27.1.5.2.2.1.1 | ColumncoolingUnitConfigurationDiscreteTableIndex | not-accessible | mandatory | The static reference identifier for each table entry. |
| 1.3.6.1.4.1.318.1.1.27.1.5.2.2.1.2 | ColumncoolingUnitConfigurationDiscreteDescription | read-only | mandatory | A text description of the information presented in this table's 'value' OIDs. |
| 1.3.6.1.4.1.318.1.1.27.1.5.2.2.1.3 | ColumncoolingUnitConfigurationDiscreteValueAsString | read-only | mandatory | The actual value of the current table entry expressed as a string. |
| 1.3.6.1.4.1.318.1.1.27.1.5.2.2.1.4 | ColumncoolingUnitConfigurationDiscreteValueAsInteger | read-write | mandatory | The actual value of the current table entry expressed as an integer value. |
| 1.3.6.1.4.1.318.1.1.27.1.5.2.2.1.5 | ColumncoolingUnitConfigurationDiscreteIntegerReferenceKey | read-only | mandatory | A complete listing of all possible coolingUnitConfigurationDiscreteValueAsInteger values paired with their identifying strings. |
| 1.3.6.1.4.1.318.1.1.27.1.5.2.2.1.6 | ColumncoolingUnitConfigurationDiscreteAccess | read-only | mandatory | A description of available access to coolingUnitConfigurationDiscreteValueAsInteger via SNMP client. |
| 1.3.6.1.4.1.318.1.1.27.1.5.3 | NodecoolingUnitConfigurationString | |||
| 1.3.6.1.4.1.318.1.1.27.1.5.3.1 | ScalarcoolingUnitConfigurationStringTableSize | read-only | mandatory | The potential number of entries available in coolingUnitConfigurationStringTable. |
| 1.3.6.1.4.1.318.1.1.27.1.5.3.2 | TablecoolingUnitConfigurationStringTable | not-accessible | mandatory | A table of unit configuration strings. |
| 1.3.6.1.4.1.318.1.1.27.1.5.3.2.1 | RowcoolingUnitConfigurationStringEntry | not-accessible | mandatory | An element of coolingUnitConfigurationStringTable. |
| 1.3.6.1.4.1.318.1.1.27.1.5.3.2.1.1 | ColumncoolingUnitConfigurationStringTableIndex | not-accessible | mandatory | The static reference identifier for each table entry. |
| 1.3.6.1.4.1.318.1.1.27.1.5.3.2.1.2 | ColumncoolingUnitConfigurationStringDescription | read-only | mandatory | A text description of the information presented in coolingUnitConfigurationStringValue. |
| 1.3.6.1.4.1.318.1.1.27.1.5.3.2.1.3 | ColumncoolingUnitConfigurationStringValue | read-write | mandatory | The actual value of the current table entry. |
| 1.3.6.1.4.1.318.1.1.27.1.5.3.2.1.4 | ColumncoolingUnitConfigurationStringMaxLength | read-only | mandatory | The maximum string length supported by coolingUnitConfigurationStringValue. |
| 1.3.6.1.4.1.318.1.1.27.1.5.3.2.1.5 | ColumncoolingUnitConfigurationStringAccess | read-only | mandatory | A description of available access to coolingUnitConfigurationStringValue via SNMP client. |
| 1.3.6.1.4.1.318.1.1.27.1.6 | NodecoolingUnitExtended | |||
| 1.3.6.1.4.1.318.1.1.27.1.6.1 | NodecoolingUnitExtendedAnalog | |||
| 1.3.6.1.4.1.318.1.1.27.1.6.1.1 | ScalarcoolingUnitExtendedAnalogTableSize | read-only | mandatory | The potential number of entries available in coolingUnitExtendedAnalogTable. |
| 1.3.6.1.4.1.318.1.1.27.1.6.1.2 | TablecoolingUnitExtendedAnalogTable | not-accessible | mandatory | A table of secondary analog data for the cooling unit or one of its components. |
| 1.3.6.1.4.1.318.1.1.27.1.6.1.2.1 | RowcoolingUnitExtendedAnalogEntry | not-accessible | mandatory | An element of coolingUnitExtendedAnalogTable. |
| 1.3.6.1.4.1.318.1.1.27.1.6.1.2.1.1 | ColumncoolingUnitExtendedAnalogTableIndex | not-accessible | mandatory | The static reference identifier for each table entry. This identifier may reference different table entries in different unit models. |
| 1.3.6.1.4.1.318.1.1.27.1.6.1.2.1.2 | ColumncoolingUnitExtendedAnalogDescription | read-only | mandatory | A text description of the information presented in coolingUnitExtendedAnalogValue. |
| 1.3.6.1.4.1.318.1.1.27.1.6.1.2.1.3 | ColumncoolingUnitExtendedAnalogValue | read-only | mandatory | The scaled value of the current table entry (multiplied by coolingUnitExtendedAnalogScale for integer presentation). |
| 1.3.6.1.4.1.318.1.1.27.1.6.1.2.1.4 | ColumncoolingUnitExtendedAnalogUnits | read-only | mandatory | The unit of measure by which coolingUnitExtendedAnalogValue is expressed. |
| 1.3.6.1.4.1.318.1.1.27.1.6.1.2.1.5 | ColumncoolingUnitExtendedAnalogScale | read-only | mandatory | The factor by which coolingUnitExtendedAnalogValue is expressed. |
| 1.3.6.1.4.1.318.1.1.27.1.6.2 | NodecoolingUnitExtendedDiscrete | |||
| 1.3.6.1.4.1.318.1.1.27.1.6.2.1 | ScalarcoolingUnitExtendedDiscreteTableSize | read-only | mandatory | The potential number of entries available in coolingUnitExtendedDiscreteTable. |
| 1.3.6.1.4.1.318.1.1.27.1.6.2.2 | TablecoolingUnitExtendedDiscreteTable | not-accessible | mandatory | A table of secondary discrete cooling unit data. |
| 1.3.6.1.4.1.318.1.1.27.1.6.2.2.1 | RowcoolingUnitExtendedDiscreteEntry | not-accessible | mandatory | An element of coolingUnitExtendedDiscreteTable. |
| 1.3.6.1.4.1.318.1.1.27.1.6.2.2.1.1 | ColumncoolingUnitExtendedDiscreteTableIndex | not-accessible | mandatory | The static reference identifier for each table entry. This identifier may reference different table entries in different unit models. |
| 1.3.6.1.4.1.318.1.1.27.1.6.2.2.1.2 | ColumncoolingUnitExtendedDiscreteDescription | read-only | mandatory | A text description of the information presented in this table's 'value' OIDs. |
| 1.3.6.1.4.1.318.1.1.27.1.6.2.2.1.3 | ColumncoolingUnitExtendedDiscreteValueAsString | read-only | mandatory | The actual value of the current table entry expressed as a string. |
| 1.3.6.1.4.1.318.1.1.27.1.6.2.2.1.4 | ColumncoolingUnitExtendedDiscreteValueAsInteger | read-only | mandatory | The actual value of the current table entry expressed as an integer value. |
| 1.3.6.1.4.1.318.1.1.27.1.6.2.2.1.5 | ColumncoolingUnitExtendedDiscreteIntegerReferenceKey | read-only | mandatory | A complete listing of all possible coolingUnitExtendedDiscreteValueAsInteger values paired with their identifying strings. |
| 1.3.6.1.4.1.318.1.1.27.1.6.3 | NodecoolingUnitExtendedString | |||
| 1.3.6.1.4.1.318.1.1.27.1.6.3.1 | ScalarcoolingUnitExtendedStringTableSize | read-only | mandatory | The potential number of entries available in coolingUnitExtendedStringTable. |
| 1.3.6.1.4.1.318.1.1.27.1.6.3.2 | TablecoolingUnitExtendedStringTable | not-accessible | mandatory | A table of secondary unit reference data. |
| 1.3.6.1.4.1.318.1.1.27.1.6.3.2.1 | RowcoolingUnitExtendedStringEntry | not-accessible | mandatory | An element of coolingUnitExtendedStringTable. |
| 1.3.6.1.4.1.318.1.1.27.1.6.3.2.1.1 | ColumncoolingUnitExtendedStringTableIndex | not-accessible | mandatory | The static reference identifier for each table entry. This identifier may reference different table entries in different unit models. |
| 1.3.6.1.4.1.318.1.1.27.1.6.3.2.1.2 | ColumncoolingUnitExtendedStringDescription | read-only | mandatory | A text description of the information presented in coolingUnitExtendedStringValue. |
| 1.3.6.1.4.1.318.1.1.27.1.6.3.2.1.3 | ColumncoolingUnitExtendedStringValue | read-only | mandatory | The actual value of the current table entry. |
| 1.3.6.1.4.1.318.1.1.28 | NodepowerManagementModule | |||
| 1.3.6.1.4.1.318.1.1.28.1 | NodepmmIdent | |||
| 1.3.6.1.4.1.318.1.1.28.1.1 | ScalarpmmIdentModelNumber | read-only | mandatory | A character string identifying the model number of the PMM. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.28.1.2 | ScalarpmmIdentSerialNumber | read-only | mandatory | A character string identifying the serial number of the PMM. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.28.1.3 | ScalarpmmIdentDateOfManufacture | read-only | mandatory | The date when the PMM was manufactured in mm/dd/yyyy format. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.28.1.4 | ScalarpmmIdentHMISerialNumber | read-only | mandatory | A character string identifying the serial number of the HMI. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.28.1.5 | ScalarpmmIdentHMIHardwareRev | read-only | mandatory | The hardware revision of the HMI. This value is set at the factory. |
| 1.3.6.1.4.1.318.1.1.28.1.6 | ScalarpmmIdentHMIFirmwareAppRev | read-only | mandatory | An ID string identifying the application firmware revision of the HMI. |
| 1.3.6.1.4.1.318.1.1.28.1.7 | ScalarpmmIdentHMIFirmwareAppOSRev | read-only | mandatory | An ID string identifying the application operating system firmware revision of the HMI. |
| 1.3.6.1.4.1.318.1.1.28.2 | NodepmmDevice | |||
| 1.3.6.1.4.1.318.1.1.28.2.1 | ScalarpmmDeviceNominalInputVoltage | read-only | mandatory | The nominal input voltage to the PMM. Measured in Volts, line-to-line for a 3-wire (delta) service or line-to-neutral for a 4-wire (wye) service. |
| 1.3.6.1.4.1.318.1.1.28.2.2 | ScalarpmmDeviceServiceType | read-only | mandatory | The type of utility input to the PMM. Either 3 wires (delta), or 4 wires (wye). |
| 1.3.6.1.4.1.318.1.1.28.2.3 | ScalarpmmDeviceNominalOutputVoltage | read-only | mandatory | The nominal line-to-neutral output voltage to the load measured in Volts. |
| 1.3.6.1.4.1.318.1.1.28.3 | NodepmmMonitoring | |||
| 1.3.6.1.4.1.318.1.1.28.3.1 | NodepmmInput | |||
| 1.3.6.1.4.1.318.1.1.28.3.1.1 | ScalarpmmInputMeterTableSize | read-only | mandatory | The number of input meters attached to the system. |
| 1.3.6.1.4.1.318.1.1.28.3.1.2 | TablepmmInputTable | not-accessible | mandatory | A list of input meter entries. |
| 1.3.6.1.4.1.318.1.1.28.3.1.2.1 | RowpmmInputEntry | not-accessible | mandatory | An entry containing information applicable to a particular input meter. |
| 1.3.6.1.4.1.318.1.1.28.3.1.2.1.1 | ColumnpmmInputMeterIndex | read-only | mandatory | The input meter identifier. |
| 1.3.6.1.4.1.318.1.1.28.3.1.2.1.2 | ColumnpmmInputFrequency | read-only | mandatory | The input frequency in tenths of Hertz. |
| 1.3.6.1.4.1.318.1.1.28.3.1.2.1.3 | ColumnpmmInputTotalActivePower | read-only | mandatory | Shows the total input active power in tenths of kW. |
| 1.3.6.1.4.1.318.1.1.28.3.1.2.1.4 | ColumnpmmInputTotalApparentPower | read-only | mandatory | Shows the total input apparent power in tenths of kVA. |
| 1.3.6.1.4.1.318.1.1.28.3.1.2.1.5 | ColumnpmmInputTotalPowerFactor | read-only | mandatory | Indicates the total power factor. A value of 100 representing a unity power factor (1.00). Specified in hundredths. |
| 1.3.6.1.4.1.318.1.1.28.3.1.2.1.6 | ColumnpmmInputActiveEnergyDelivered | read-only | mandatory | Shows the input active energy delivered in tenths of kWh. |
| 1.3.6.1.4.1.318.1.1.28.3.1.2.1.7 | ColumnpmmInputActiveEnergyReceived | read-only | mandatory | Shows the input active energy received in tenths of kWh. |
| 1.3.6.1.4.1.318.1.1.28.3.1.2.1.8 | ColumnpmmInputApparentEnergyDelivered | read-only | mandatory | Shows the input apparent energy delivered in tenths of kVAh. |
| 1.3.6.1.4.1.318.1.1.28.3.1.2.1.9 | ColumnpmmInputApparentEnergyReceived | read-only | mandatory | Shows the input apparent energy received in tenths of kVAh. |
| 1.3.6.1.4.1.318.1.1.28.3.1.2.1.10 | ColumnpmmInputFrequencyDeviation | read-write | mandatory | Shows the input frequency deviation in Hertz. |
| 1.3.6.1.4.1.318.1.1.28.3.1.2.1.11 | ColumnpmmInputPowerFactorDeviation | read-write | mandatory | Shows the input power factor deviation. Specified in tenths. A value of zero indicates that the threshold is disabled. |
| 1.3.6.1.4.1.318.1.1.28.3.1.2.1.12 | ColumnpmmInputMinVoltThreshold | read-write | mandatory | Threshold below which an input minimum voltage condition will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDevic… |
| 1.3.6.1.4.1.318.1.1.28.3.1.2.1.13 | ColumnpmmInputLowVoltThreshold | read-write | mandatory | Threshold below which an input low voltage condition will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceNom… |
| 1.3.6.1.4.1.318.1.1.28.3.1.2.1.14 | ColumnpmmInputHighVoltThreshold | read-write | mandatory | Threshold above which an input high voltage condition will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceNo… |
| 1.3.6.1.4.1.318.1.1.28.3.1.2.1.15 | ColumnpmmInputMaxVoltThreshold | read-write | mandatory | Threshold above which an input maximum voltage condition will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDevic… |
| 1.3.6.1.4.1.318.1.1.28.3.1.2.1.16 | ColumnpmmInputMinCurrentThreshold | read-write | mandatory | Threshold below which an input minimum current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that … |
| 1.3.6.1.4.1.318.1.1.28.3.1.2.1.17 | ColumnpmmInputLowCurrentThreshold | read-write | mandatory | Threshold below which an input low current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the … |
| 1.3.6.1.4.1.318.1.1.28.3.1.2.1.18 | ColumnpmmInputHighCurrentThreshold | read-write | mandatory | Threshold above which an input high current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the… |
| 1.3.6.1.4.1.318.1.1.28.3.1.2.1.19 | ColumnpmmInputMaxCurrentThreshold | read-write | mandatory | Threshold above which an input maximum current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that … |
| 1.3.6.1.4.1.318.1.1.28.3.1.2.1.20 | ColumnpmmInputMinApparentPowerThreshold | read-write | mandatory | Threshold below which an input minimum apparent power condition will be generated. Specified as a percent deviation from nominal power rating. A value of zero … |
| 1.3.6.1.4.1.318.1.1.28.3.1.2.1.21 | ColumnpmmInputMaxApparentPowerThreshold | read-write | mandatory | Threshold above which an input maximum apparent power condition will be generated. Specified as a percent deviation from nominal power rating. A value of zero … |
| 1.3.6.1.4.1.318.1.1.28.3.1.2.1.22 | ColumnpmmInputOverActivePowerThreshold | read-write | mandatory | Threshold above which an input over active power condition will be generated. Specified as a percent deviation from nominal power rating. A value of zero indic… |
| 1.3.6.1.4.1.318.1.1.28.3.1.2.1.23 | ColumnpmmInputBreakerState | read-only | mandatory | This value indicates the current state of input breaker. 1 will indicate open, 2 will indicate closed, 3 will indicate unknown. |
| 1.3.6.1.4.1.318.1.1.28.3.1.2.1.24 | ColumnpmmInputBreakerOpenAlarm | read-write | mandatory | Breaker open alarm status. 1 will indicate enabled, 2 will indicate disabled, 3 will indicate unknown. |
| 1.3.6.1.4.1.318.1.1.28.3.1.3 | TablepmmInputPhaseTable | not-accessible | mandatory | A list of input table entries. The number of entries is given by the value of pmmInputMeterTableSize OID. |
| 1.3.6.1.4.1.318.1.1.28.3.1.3.1 | RowpmmInputPhaseEntry | not-accessible | mandatory | An entry containing information applicable to a particular input phase. |
| 1.3.6.1.4.1.318.1.1.28.3.1.3.1.1 | ColumnpmmInputMeterNum | read-only | mandatory | The input meter identifier. |
| 1.3.6.1.4.1.318.1.1.28.3.1.3.1.2 | ColumnpmmInputPhase | read-only | mandatory | Input phase index. |
| 1.3.6.1.4.1.318.1.1.28.3.1.3.1.3 | ColumnpmmInputVoltageLtoL | read-only | mandatory | Line-to-line input voltage available. Measured in tenths of Volts. |
| 1.3.6.1.4.1.318.1.1.28.3.1.3.1.4 | ColumnpmmInputVoltageLtoN | read-only | mandatory | Line-to-neutral input voltage available. Measured in tenths of Volts. |
| 1.3.6.1.4.1.318.1.1.28.3.1.3.1.5 | ColumnpmmInputPhaseCurrent | read-only | mandatory | Input current per phase. Measured in tenths of Amps. |
| 1.3.6.1.4.1.318.1.1.28.3.1.3.1.6 | ColumnpmmInputActivePower | read-only | mandatory | Input power per phase. Measured in tenths of kW. |
| 1.3.6.1.4.1.318.1.1.28.3.1.3.1.7 | ColumnpmmInputApparentPower | read-only | mandatory | Input power per phase. Measured in tenths of kVA. |
| 1.3.6.1.4.1.318.1.1.28.3.1.3.1.8 | ColumnpmmInputPowerFactor | read-only | mandatory | Indicates the power factor of the input per phase. A value of 100 representing a unity power factor (1.00). Specified in hundredths. |
| 1.3.6.1.4.1.318.1.1.28.3.2 | NodepmmOutput | |||
| 1.3.6.1.4.1.318.1.1.28.3.2.1 | ScalarpmmOutputMeterTableSize | read-only | mandatory | The number of output meters attached to the system. |
| 1.3.6.1.4.1.318.1.1.28.3.2.2 | TablepmmOutputTable | not-accessible | mandatory | A list of output meter entries. |
| 1.3.6.1.4.1.318.1.1.28.3.2.2.1 | RowpmmOutputEntry | not-accessible | mandatory | An entry containing information applicable to a particular output meter. |
| 1.3.6.1.4.1.318.1.1.28.3.2.2.1.1 | ColumnpmmOutputMeterIndex | read-only | mandatory | The output meter identifier. |
| 1.3.6.1.4.1.318.1.1.28.3.2.2.1.2 | ColumnpmmOutputFrequency | read-only | mandatory | The output frequency in tenths of Hertz. |
| 1.3.6.1.4.1.318.1.1.28.3.2.2.1.3 | ColumnpmmOutputTotalActivePower | read-only | mandatory | Shows the total output active power in tenths of kW. |
| 1.3.6.1.4.1.318.1.1.28.3.2.2.1.4 | ColumnpmmOutputTotalApparentPower | read-only | mandatory | Shows the total output apparent power in tenths of kVA. |
| 1.3.6.1.4.1.318.1.1.28.3.2.2.1.5 | ColumnpmmOutputTotalPowerFactor | read-only | mandatory | Indicates the total power factor. A value of 100 representing a unity power factor (1.00). Specified in hundredths. |
| 1.3.6.1.4.1.318.1.1.28.3.2.2.1.6 | ColumnpmmOutputActiveEnergyDelivered | read-only | mandatory | Shows the output active energy delivered in tenths of kWh. |
| 1.3.6.1.4.1.318.1.1.28.3.2.2.1.7 | ColumnpmmOutputActiveEnergyReceived | read-only | mandatory | Shows the output active energy received in tenths of kWh. |
| 1.3.6.1.4.1.318.1.1.28.3.2.2.1.8 | ColumnpmmOutputApparentEnergyDelivered | read-only | mandatory | Shows the output apparent energy delivered in tenths of kVAh. |
| 1.3.6.1.4.1.318.1.1.28.3.2.2.1.9 | ColumnpmmOutputApparentEnergyReceived | read-only | mandatory | Shows the output apparent energy received in tenths of kVAh. |
| 1.3.6.1.4.1.318.1.1.28.3.2.2.1.10 | ColumnpmmOutputFrequencyDeviation | read-write | mandatory | Shows the output frequency deviation in Hertz. |
| 1.3.6.1.4.1.318.1.1.28.3.2.2.1.11 | ColumnpmmOutputPowerFactorDeviation | read-write | mandatory | Shows the output power factor deviation. Specified in tenths. A value of zero indicates that the threshold is disabled. |
| 1.3.6.1.4.1.318.1.1.28.3.2.2.1.12 | ColumnpmmOutputMinVoltThreshold | read-write | mandatory | Threshold below which an output minimum voltage condition will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDevi… |
| 1.3.6.1.4.1.318.1.1.28.3.2.2.1.13 | ColumnpmmOutputLowVoltThreshold | read-write | mandatory | Threshold below which an output low voltage condition will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceNo… |
| 1.3.6.1.4.1.318.1.1.28.3.2.2.1.14 | ColumnpmmOutputHighVoltThreshold | read-write | mandatory | Threshold above which an output high voltage condition will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceN… |
| 1.3.6.1.4.1.318.1.1.28.3.2.2.1.15 | ColumnpmmOutputMaxVoltThreshold | read-write | mandatory | Threshold above which an output maximum voltage condition will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDevi… |
| 1.3.6.1.4.1.318.1.1.28.3.2.2.1.16 | ColumnpmmOutputMinCurrentThreshold | read-write | mandatory | Threshold below which an output minimum current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that… |
| 1.3.6.1.4.1.318.1.1.28.3.2.2.1.17 | ColumnpmmOutputLowCurrentThreshold | read-write | mandatory | Threshold below which an output low current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the… |
| 1.3.6.1.4.1.318.1.1.28.3.2.2.1.18 | ColumnpmmOutputHighCurrentThreshold | read-write | mandatory | Threshold above which an output high current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that th… |
| 1.3.6.1.4.1.318.1.1.28.3.2.2.1.19 | ColumnpmmOutputMaxCurrentThreshold | read-write | mandatory | Threshold above which an output maximum current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that… |
| 1.3.6.1.4.1.318.1.1.28.3.2.2.1.20 | ColumnpmmOutputMinApparentPowerThreshold | read-write | mandatory | Threshold below which an output minimum apparent power condition will be generated. Specified as a percent deviation from nominal power rating. A value of zero… |
| 1.3.6.1.4.1.318.1.1.28.3.2.2.1.21 | ColumnpmmOutputMaxApparentPowerThreshold | read-write | mandatory | Threshold above which an output maximum apparent power condition will be generated. Specified as a percent deviation from nominal power rating. A value of zero… |
| 1.3.6.1.4.1.318.1.1.28.3.2.2.1.22 | ColumnpmmOutputOverActivePowerThreshold | read-write | mandatory | Threshold above which an output over active power condition will be generated. Specified as a percent deviation from nominal power rating. A value of zero indi… |
| 1.3.6.1.4.1.318.1.1.28.3.2.2.1.23 | ColumnpmmOutputPhaseLossThreshold | read-write | mandatory | Threshold below which an output phase loss condition will be generated. Specified as a percent deviation from nominal voltage represented in the OID pmmDeviceN… |
| 1.3.6.1.4.1.318.1.1.28.3.2.2.1.24 | ColumnpmmOutputBreakerState | read-only | mandatory | This value indicates the current state of output breaker. 1 will indicate open, 2 will indicate closed, 3 will indicate unknown. |
| 1.3.6.1.4.1.318.1.1.28.3.2.2.1.25 | ColumnpmmOutputBreakerOpenAlarm | read-write | mandatory | Breaker open alarm status. 1 will indicate enabled, 2 will indicate disabled, 3 will indicate unknown. |
| 1.3.6.1.4.1.318.1.1.28.3.2.3 | TablepmmOutputPhaseTable | not-accessible | mandatory | A list of output table entries. The number of entries is given by the value of pmmOutputMeterTableSize OID. |
| 1.3.6.1.4.1.318.1.1.28.3.2.3.1 | RowpmmOutputPhaseEntry | not-accessible | mandatory | An entry containing information applicable to a particular output phase. |
| 1.3.6.1.4.1.318.1.1.28.3.2.3.1.1 | ColumnpmmOutputMeterNum | read-only | mandatory | The output meter identifier. |
| 1.3.6.1.4.1.318.1.1.28.3.2.3.1.2 | ColumnpmmOutputPhase | read-only | mandatory | Output phase index. |
| 1.3.6.1.4.1.318.1.1.28.3.2.3.1.3 | ColumnpmmOutputVoltageLtoL | read-only | mandatory | Line-to-line output voltage available. Measured in tenths of Volts. |
| 1.3.6.1.4.1.318.1.1.28.3.2.3.1.4 | ColumnpmmOutputVoltageLtoN | read-only | mandatory | Line-to-neutral output voltage available. Measured in tenths of Volts. |
| 1.3.6.1.4.1.318.1.1.28.3.2.3.1.5 | ColumnpmmOutputPhaseCurrent | read-only | mandatory | Load current per phase. Measured in tenths of Amps. |
| 1.3.6.1.4.1.318.1.1.28.3.2.3.1.6 | ColumnpmmOutputActivePower | read-only | mandatory | Output power per phase. Measured in tenths of kW. |
| 1.3.6.1.4.1.318.1.1.28.3.2.3.1.7 | ColumnpmmOutputApparentPower | read-only | mandatory | Output power per phase. Measured in tenths of kVA. |
| 1.3.6.1.4.1.318.1.1.28.3.2.3.1.8 | ColumnpmmOutputPowerFactor | read-only | mandatory | Indicates the power factor of the output per phase. A value of 100 representing a unity power factor (1.00). Specified in hundredths. |
| 1.3.6.1.4.1.318.1.1.28.3.3 | NodepmmBranch | |||
| 1.3.6.1.4.1.318.1.1.28.3.3.1 | ScalarpmmnumofBranchMeters | read-only | mandatory | The number of branch meters attached to the system. |
| 1.3.6.1.4.1.318.1.1.28.3.3.2 | ScalarpmmBranchBreakerTableSize | read-only | mandatory | The number of branch breaker entries. |
| 1.3.6.1.4.1.318.1.1.28.3.3.3 | TablepmmBranchBreakerTable | not-accessible | mandatory | A list of branch breaker table entries. The number of entries is contained in the pmmBranchBreakerTableSize OID. |
| 1.3.6.1.4.1.318.1.1.28.3.3.3.1 | RowpmmBranchBreakerEntry | not-accessible | mandatory | An entry containing information applicable to a particular branch breaker (panel/circuit position). |
| 1.3.6.1.4.1.318.1.1.28.3.3.3.1.1 | ColumnpmmBranchCircuitMeterIndex | read-only | mandatory | Index of branch circuit meter in the table. |
| 1.3.6.1.4.1.318.1.1.28.3.3.3.1.2 | ColumnpmmBranchCircuitIndex | read-only | mandatory | The branch circuit index. |
| 1.3.6.1.4.1.318.1.1.28.3.3.3.1.3 | ColumnpmmBranchCircuitNumberOfPoles | read-only | mandatory | The number of poles. |
| 1.3.6.1.4.1.318.1.1.28.3.3.3.1.4 | ColumnpmmBranchCircuitPhase | read-only | mandatory | The phase associated with branch circuit. |
| 1.3.6.1.4.1.318.1.1.28.3.3.3.1.5 | ColumnpmmBranchCircuitBreakerIdentifier | read-only | mandatory | The branch circuit identifier. |
| 1.3.6.1.4.1.318.1.1.28.3.3.3.1.6 | ColumnpmmBranchCircuitLoadIdentifier | read-only | mandatory | Identifies the name or location of the branch circuit load. |
| 1.3.6.1.4.1.318.1.1.28.3.3.3.1.7 | ColumnpmmBranchCircuitCurrent | read-only | mandatory | The branch circuit current Measured in tenths of Amps. |
| 1.3.6.1.4.1.318.1.1.28.3.3.3.1.8 | ColumnpmmBranchCircuitBreakerRating | read-only | mandatory | The rating of the branch circuit breaker in Amps. |
| 1.3.6.1.4.1.318.1.1.28.3.3.3.1.9 | ColumnpmmBranchCircuitTotalActivePower | read-only | mandatory | Branch circuit total power. Measured in tenths of kW. |
| 1.3.6.1.4.1.318.1.1.28.3.3.3.1.10 | ColumnpmmBranchCircuitTotalApparentPower | read-only | mandatory | Branch circuit total apparent power. Measured in tenths of kVA. |
| 1.3.6.1.4.1.318.1.1.28.3.3.3.1.11 | ColumnpmmBranchCircuitEnergyUsage | read-only | mandatory | Indicates the energy usage in tenths of kWh or -1 when not available. |
| 1.3.6.1.4.1.318.1.1.28.3.3.3.1.12 | ColumnpmmBranchCircuitEnergyUsageResetDate | read-only | mandatory | The date that the kWh usage was reset, in the format mm/dd/yyyy. |
| 1.3.6.1.4.1.318.1.1.28.3.3.3.1.13 | ColumnpmmBranchCircuitTotalPowerFactor | read-only | mandatory | Indicates the total power factor of the branch circuit output. A value of 100 representing a unity power factor (1.00) Specified in hundredths. |
| 1.3.6.1.4.1.318.1.1.28.3.3.3.1.14 | ColumnpmmBranchCircuitBreakerState | read-only | mandatory | This value indicates the current state of branch circuit breaker. 1 will indicate open, 2 will indicate closed, 3 will indicate unknown. |
| 1.3.6.1.4.1.318.1.1.28.3.3.3.1.15 | ColumnpmmBranchCircuitMinCurrentThreshold | read-write | mandatory | Threshold below which a branch circuit minimum current condition will be generated. Specified as a percent of the branch breaker rating represented in the OID … |
| 1.3.6.1.4.1.318.1.1.28.3.3.3.1.16 | ColumnpmmBranchCircuitLowCurrentThreshold | read-write | mandatory | Threshold below which a branch circuit low current condition will be generated. Specified as a percent of the branch breaker rating represented in the OID pmmB… |
| 1.3.6.1.4.1.318.1.1.28.3.3.3.1.17 | ColumnpmmBranchCircuitHighCurrentThreshold | read-write | mandatory | Threshold below which a branch circuit high current condition will be generated. Specified as a percent of the branch breaker rating represented in the OID pmm… |
| 1.3.6.1.4.1.318.1.1.28.3.3.3.1.18 | ColumnpmmBranchCircuitMaxCurrentThreshold | read-write | mandatory | Threshold below which a branch circuit maximum current condition will be generated. Specified as a percent of the branch breaker rating represented in the OID … |
| 1.3.6.1.4.1.318.1.1.28.3.3.3.1.19 | ColumnpmmBranchCircuitMinApparentPowerThreshold | read-write | mandatory | Threshold below which a branch circuit minimum apparent power condition will be generated. Specified as a percent of the branch breaker apparent power rating. … |
| 1.3.6.1.4.1.318.1.1.28.3.3.3.1.20 | ColumnpmmBranchCircuitMaxApparentPowerThreshold | read-write | mandatory | Threshold below which a branch circuit maximum apparent power condition will be generated. Specified as a percent of the branch breaker apparent power rating. … |
| 1.3.6.1.4.1.318.1.1.28.3.3.3.1.21 | ColumnpmmBranchCircuitAlaramGeneration | read-only | mandatory | Alarm generation status. 1 will indicate enabled, 2 will indicate disabled, 3 will indicate unknown. |
| 1.3.6.1.4.1.318.1.1.28.3.3.3.1.22 | ColumnpmmBranchCircuitBreakerOpenAlarm | read-write | mandatory | Breaker open alarm status. 1 will indicate enabled, 2 will indicate disabled, 3 will indicate unknown. |
| 1.3.6.1.4.1.318.1.2 | Nodesoftware | |||
| 1.3.6.1.4.1.318.1.2.1 | NodepowerNetSubAgent | |||
| 1.3.6.1.4.1.318.1.2.1.1 | NodepowerNetSoftwareSystem | |||
| 1.3.6.1.4.1.318.1.2.1.1.1 | ScalarpowerNetSoftwareSystemDescription | read-only | mandatory | A brief description of the PowerNet sub-agent. |
| 1.3.6.1.4.1.318.1.2.1.1.2 | ScalarpowerNetSoftwareOid | read-only | mandatory | The object identifier of the PowerNet sub-agent. |
| 1.3.6.1.4.1.318.1.2.1.1.3 | ScalarpowerNetSoftwareSystemUpTime | read-only | mandatory | The time that the sub-agent has been running. |
| 1.3.6.1.4.1.318.1.2.1.2 | NodepowerNetSoftwareConfig | |||
| 1.3.6.1.4.1.318.1.2.1.2.1 | ScalarpowerNetSoftwareTableSize | read-only | mandatory | The number of software modules supporting the UPS. |
| 1.3.6.1.4.1.318.1.2.1.2.2 | TablepowerNetSoftwareTable | not-accessible | mandatory | A list of the software monitoring the UPS. |
| 1.3.6.1.4.1.318.1.2.1.2.2.1 | RowpowerNetSoftwareEntry | not-accessible | mandatory | An entry containing information on a software module. |
| 1.3.6.1.4.1.318.1.2.1.2.2.1.1 | ColumnmoduleNumber | read-only | mandatory | The index into the Software Entry Table |
| 1.3.6.1.4.1.318.1.2.1.2.2.1.2 | ColumnmoduleName | read-only | mandatory | The name of the software module. |
| 1.3.6.1.4.1.318.1.2.1.2.2.1.3 | ColumnmoduleVersion | read-only | mandatory | The version of the software module. |
| 1.3.6.1.4.1.318.1.2.1.2.2.1.4 | ColumnmoduleDate | read-only | mandatory | The date of the software module represented as mm-dd-yy. |
| 1.3.6.1.4.1.318.1.2.2 | NodestruxureWareOperations | |||
| 1.3.6.1.4.1.318.1.2.2.1 | NodestruxureWareOperationsStatus | |||
| 1.3.6.1.4.1.318.1.2.2.1.1 | ScalarserverStatus | read-only | mandatory | The status of the StruxureWare Operations server: 1: The status of the application server is unknown. Check Webmin and if the problem persists, contact Technic… |
| 1.3.6.1.4.1.318.1.2.2.1.2 | ScalardatabaseStatus | read-only | mandatory | The status of the StruxureWare Operations database: 1: The status of the database is unknown. Check Webmin and if the problem persists, contact Technical Suppo… |
| 1.3.6.1.4.1.318.1.2.2.1.3 | ScalarloadBalancerStatus | read-only | mandatory | The status of the StruxureWare Operations load balancer: 1: Load Balancer status is unknown. Check Webmin and if the problem persists, contact Technical Suppor… |
| 1.3.6.1.4.1.318.1.2.2.1.4 | ScalaressentialServicesStatus | read-only | mandatory | The status of the StruxureWare Operations essential services: 1: Unknown status. Check Webmin and if the problem persists, contact Technical Support. 2: Essent… |
| 1.3.6.1.4.1.318.1.2.2.1.5 | ScalaretlStatus | read-only | mandatory | The status of the StruxureWare Operations ETL services: 1: Unknown status. Check the network configuration and the server network settings. If the problem pers… |
| 1.3.6.1.4.1.318.1.2.3 | NodepowerChuteNetworkShutdown | |||
| 1.3.6.1.4.1.318.1.2.3.1 | NodepcnsIdent | |||
| 1.3.6.1.4.1.318.1.2.3.1.1 | Scalarpcnshostname | read-only | mandatory | The hostname of the PCNS instance. |
| 1.3.6.1.4.1.318.1.2.3.1.2 | ScalarpcnsVersion | read-only | mandatory | The version of PCNS installed. x.x.x |
| 1.3.6.1.4.1.318.1.2.3.1.3 | ScalarpcnsOS | read-only | mandatory | The version of OS PCNS is Installed on. |
| 1.3.6.1.4.1.318.1.2.3.1.4 | ScalarpcnsJavaVersion | read-only | mandatory | The version of Java PCNS is running on. |
| 1.3.6.1.4.1.318.1.2.3.2 | NodepcnsNetworking | |||
| 1.3.6.1.4.1.318.1.2.3.2.1 | ScalarpcnsUIProtocol | read-only | mandatory | Web Protocol used to connect to the PCNS UI. |
| 1.3.6.1.4.1.318.1.2.3.2.2 | ScalarpcnsHttpPort | read-only | mandatory | Port used for PCNS http UI. |
| 1.3.6.1.4.1.318.1.2.3.2.3 | ScalarpcnsHttpsPort | read-only | mandatory | Port used for PCNS https UI. |
| 1.3.6.1.4.1.318.1.2.3.2.4 | ScalarpcnsNetworkConfig | read-only | mandatory | Configuration of the TCP Network. |
| 1.3.6.1.4.1.318.1.2.3.2.5 | ScalarpcnsVirtualInstall | read-only | mandatory | Virtualization technology in use by PCNS. |
| 1.3.6.1.4.1.318.1.2.3.3 | NodepcnsNMC | |||
| 1.3.6.1.4.1.318.1.2.3.3.1 | ScalarpcnsMode | read-only | mandatory | Configuration mode of the UPS(s) which PCNS is monitoring. |
| 1.3.6.1.4.1.318.1.2.3.3.2 | ScalarpcnsNMCPort | read-only | mandatory | Port used to connect to all of the Network Management Card(s). |
| 1.3.6.1.4.1.318.1.2.3.3.3 | ScalarpcnsNMCProtocol | read-only | mandatory | Web Protocol used to connect to all of the Network Management Card(s). |
| 1.3.6.1.4.1.318.1.2.3.3.4 | TablepcnsNmcTable | not-accessible | mandatory | The Network Management Cards in the UPS's which PCNS is monitoring to provide safe shutdown. |
| 1.3.6.1.4.1.318.1.2.3.3.4.1 | RowpcnsNmcEntry | not-accessible | mandatory | Details of the NMC. |
| 1.3.6.1.4.1.318.1.2.3.3.4.1.1 | ColumnpcnsNmcIndex | read-only | mandatory | Index of the NMC within PCNS setup. |
| 1.3.6.1.4.1.318.1.2.3.3.4.1.2 | ColumnpcnsNmcAddr | read-only | mandatory | The IP address of the NMC. |
| 1.3.6.1.4.1.318.1.2.3.3.4.1.3 | ColumnpcnsNmcOutlet | read-only | mandatory | The Outlet Group which PCNS is enrolled with on the NMC. |
| 1.3.6.1.4.1.318.1.2.3.4 | NodepcnsEvents | |||
| 1.3.6.1.4.1.318.1.2.3.4.1 | NodepcnsPowerFailed | |||
| 1.3.6.1.4.1.318.1.2.3.4.1.1 | ScalarpcnsPowerFailedDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.1.2 | ScalarpcnsPowerFailedEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.1.3 | ScalarpcnsPowerFailedEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.1.4 | ScalarpcnsPowerFailedCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.1.5 | ScalarpcnsPowerFailedCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.1.6 | ScalarpcnsPowerFailedEnableShutdown | read-write | mandatory | Perform a graceful shutdown of the server when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.1.7 | ScalarpcnsPowerFailedShutdownDelay | read-write | mandatory | How long to wait after event occurs before performing a graceful shutdown of the server (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.2 | NodepcnsPowerRestored | |||
| 1.3.6.1.4.1.318.1.2.3.4.2.1 | ScalarpcnsPowerRestoredDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.2.2 | ScalarpcnsPowerRestoredEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.2.3 | ScalarpcnsPowerRestoredEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.2.4 | ScalarpcnsPowerRestoredCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.2.5 | ScalarpcnsPowerRestoredCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.3 | NodepcnsOverload | |||
| 1.3.6.1.4.1.318.1.2.3.4.3.1 | ScalarpcnsOverloadDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.3.2 | ScalarpcnsOverloadEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.3.3 | ScalarpcnsOverloadEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.3.4 | ScalarpcnsOverloadCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.3.5 | ScalarpcnsOverloadCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.3.6 | ScalarpcnsOverloadEnableShutdown | read-write | mandatory | Perform a graceful shutdown of the server when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.3.7 | ScalarpcnsOverloadShutdownDelay | read-write | mandatory | How long to wait after event occurs before performing a graceful shutdown of the server (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.4 | NodepcnsOverloadSolved | |||
| 1.3.6.1.4.1.318.1.2.3.4.4.1 | ScalarpcnsOverloadSolvedDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.4.2 | ScalarpcnsOverloadSolvedEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.4.3 | ScalarpcnsOverloadSolvedEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.4.4 | ScalarpcnsOverloadSolvedCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.4.5 | ScalarpcnsOverloadSolvedCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.5 | NodepcnsRunTimeExceeded | |||
| 1.3.6.1.4.1.318.1.2.3.4.5.1 | ScalarpcnsRunTimeExceededDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.5.2 | ScalarpcnsRunTimeExceededEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.5.3 | ScalarpcnsRunTimeExceededEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.5.4 | ScalarpcnsRunTimeExceededCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.5.5 | ScalarpcnsRunTimeExceededCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.5.6 | ScalarpcnsRunTimeExceededEnableShutdown | read-write | mandatory | Perform a graceful shutdown of the server when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.5.7 | ScalarpcnsRunTimeExceededShutdownDelay | read-write | mandatory | How long to wait after event occurs before performing a graceful shutdown of the server (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.6 | NodepcnsRunTimeWithinRange | |||
| 1.3.6.1.4.1.318.1.2.3.4.6.1 | ScalarpcnsRunTimeWithinRangeDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.6.2 | ScalarpcnsRunTimeWithinRangeEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.6.3 | ScalarpcnsRunTimeWithinRangeEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.6.4 | ScalarpcnsRunTimeWithinRangeCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.6.5 | ScalarpcnsRunTimeWithinRangeCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.7 | NodepcnsRunTimeBelowThreshold | |||
| 1.3.6.1.4.1.318.1.2.3.4.7.1 | ScalarpcnsRunTimeBelowThresholdDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.7.2 | ScalarpcnspcnsRunTimeBelowThresholdEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.7.3 | ScalarpcnsRunTimeBelowThresholdEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.7.4 | ScalarpcnsRunTimeBelowThresholdCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.7.6 | ScalarpcnsRunTimeBelowThresholdEnableShutdown | read-write | mandatory | Perform a graceful shutdown of the server when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.7.8 | ScalarpcnsRunTimeBelowThresholdCommandFileThreshold | read-write | mandatory | If the Runtime Remaining falls below this (seconds), the command file will run. |
| 1.3.6.1.4.1.318.1.2.3.4.7.9 | ScalarpcnsRunTimeBelowThresholdShutdownThreshold | read-write | mandatory | If the Runtime Remaining falls below this (seconds), the shutdown will begin. |
| 1.3.6.1.4.1.318.1.2.3.4.8 | NodepcnsRunTimeAboveThreshold | |||
| 1.3.6.1.4.1.318.1.2.3.4.8.1 | ScalarpcnsRunTimeAboveThresholdDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.8.2 | ScalarpcnsRunTimeAboveThresholdEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.8.3 | ScalarpcnsRunTimeAboveThresholdEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.8.4 | ScalarpcnsRunTimeAboveThresholdCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.8.5 | ScalarpcnsRunTimeAboveThresholdCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.10 | NodepcnsBatteryDischarged | |||
| 1.3.6.1.4.1.318.1.2.3.4.10.1 | ScalarpcnsBatteryDischargedDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.10.2 | ScalarpcnsBatteryDischargedEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.10.3 | ScalarpcnsBatteryDischargedEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.10.4 | ScalarpcnsBatteryDischargedCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.10.5 | ScalarpcnsBatteryDischargedCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.10.6 | ScalarpcnsBatteryDischargedEnableShutdown | read-write | mandatory | Perform a graceful shutdown of the server when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.10.7 | ScalarpcnsBatteryDischargedShutdownDelay | read-write | mandatory | How long to wait after event occurs before performing a graceful shutdown of the server (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.11 | NodepcnsBatteryChargeInRange | |||
| 1.3.6.1.4.1.318.1.2.3.4.11.1 | ScalarpcnsBatteryChargeInRangeDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.11.2 | ScalarpcnsBatteryChargeInRangeEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.11.3 | ScalarpcnsBatteryChargeInRangeEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.11.4 | ScalarpcnsBatteryChargeInRangeCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.11.5 | ScalarpcnsBatteryChargeInRangeCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.12 | NodepcnsFaultBypassEnabled | |||
| 1.3.6.1.4.1.318.1.2.3.4.12.1 | ScalarpcnsFaultBypassEnabledDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.12.2 | ScalarpcnsFaultBypassEnabledEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.12.3 | ScalarpcnsFaultBypassEnabledEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.12.4 | ScalarpcnsFaultBypassEnabledCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.12.5 | ScalarpcnsFaultBypassEnabledCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.12.6 | ScalarpcnsFaultBypassEnabledEnableShutdown | read-write | mandatory | Perform a graceful shutdown of the server when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.12.7 | ScalarpcnsFaultBypassEnabledShutdownDelay | read-write | mandatory | How long to wait after event occurs before performing a graceful shutdown of the server (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.13 | NodepcnsBypassEnabled | |||
| 1.3.6.1.4.1.318.1.2.3.4.13.1 | ScalarpcnsBypassEnabledDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.13.2 | ScalarpcnsBypassEnabledEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.13.3 | ScalarpcnsBypassEnabledEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.13.4 | ScalarpcnsBypassEnabledCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.13.5 | ScalarpcnsBypassEnabledCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.13.6 | ScalarpcnsBypassEnabledEnableShutdown | read-write | mandatory | Perform a graceful shutdown of the server when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.13.7 | ScalarpcnsBypassEnabledShutdownDelay | read-write | mandatory | How long to wait after event occurs before performing a graceful shutdown of the server (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.14 | NodepcnsBypassManualEnabled | |||
| 1.3.6.1.4.1.318.1.2.3.4.14.1 | ScalarpcnsBypassManualEnabledDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.14.2 | ScalarpcnsBypassManualEnabledEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.14.3 | ScalarpcnsBypassManualEnabledEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.14.4 | ScalarpcnsBypassManualEnabledCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.14.5 | ScalarpcnsBypassManualEnabledCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.14.6 | ScalarpcnsBypassManualEnabledEnableShutdown | read-write | mandatory | Perform a graceful shutdown of the server when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.14.7 | ScalarpcnsBypassManualEnabledShutdownDelay | read-write | mandatory | How long to wait after event occurs before performing a graceful shutdown of the server (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.15 | NodepcnsBypassDisabled | |||
| 1.3.6.1.4.1.318.1.2.3.4.15.1 | ScalarpcnsBypassDisabledDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.15.2 | ScalarpcnsBypassDisabledEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.15.3 | ScalarpcnsBypassDisabledEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.15.4 | ScalarpcnsBypassDisabledCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.15.5 | ScalarpcnsBypassDisabledCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.16 | NodepcnsBypassContactorFailed | |||
| 1.3.6.1.4.1.318.1.2.3.4.16.1 | ScalarpcnsBypassContactorFailedDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.16.2 | ScalarpcnsBypassContactorFailedEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.16.3 | ScalarpcnsBypassContactorFailedEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.16.4 | ScalarpcnsBypassContactorFailedCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.16.5 | ScalarpcnsBypassContactorFailedCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.16.6 | ScalarpcnsBypassContactorFailedEnableShutdown | read-write | mandatory | Perform a graceful shutdown of the server when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.16.7 | ScalarpcnsBypassContactorFailedShutdownDelay | read-write | mandatory | How long to wait after event occurs before performing a graceful shutdown of the server (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.17 | NodepcnsBypassContactorOk | |||
| 1.3.6.1.4.1.318.1.2.3.4.17.1 | ScalarpcnsBypassContactorOkDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.17.2 | ScalarpcnsBypassContactorOkEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.17.3 | ScalarpcnsBypassContactorOkEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.17.4 | ScalarpcnsBypassContactorOkCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.17.5 | ScalarpcnsBypassContactorOkCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.18 | NodepcnsCommunicationLostOnBattery | |||
| 1.3.6.1.4.1.318.1.2.3.4.18.1 | ScalarpcnsCommunicationLostOnBatteryDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.18.2 | ScalarpcnsCommunicationLostOnBatteryEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.18.3 | ScalarpcnsCommunicationLostOnBatteryEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.18.4 | ScalarpcnsCommunicationLostOnBatteryCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.18.5 | ScalarpcnsCommunicationLostOnBatteryCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.18.6 | ScalarpcnsCommunicationLostOnBatteryEnableShutdown | read-write | mandatory | Perform a graceful shutdown of the server when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.18.7 | ScalarpcnsCommunicationLostOnBatteryShutdownDelay | read-write | mandatory | How long to wait after event occurs before performing a graceful shutdown of the server (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.19 | NodepcnsCommunicationLost | |||
| 1.3.6.1.4.1.318.1.2.3.4.19.1 | ScalarpcnsCommunicationLostDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.19.2 | ScalarpcnsCommunicationLostEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.19.3 | ScalarpcnsCommunicationLostEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.19.4 | ScalarpcnsCommunicationLostCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.19.5 | ScalarpcnsCommunicationLostCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.19.6 | ScalarpcnsCommunicationLostEnableShutdown | read-write | mandatory | Perform a graceful shutdown of the server when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.19.7 | ScalarpcnsCommunicationLostShutdownDelay | read-write | mandatory | How long to wait after event occurs before performing a graceful shutdown of the server (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.20 | NodepcnsNetCommunicationLost | |||
| 1.3.6.1.4.1.318.1.2.3.4.20.1 | ScalarpcnsNetCommunicationLostDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.20.2 | ScalarpcnsNetCommunicationLostEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.20.3 | ScalarpcnsNetCommunicationLostEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.20.4 | ScalarpcnsNetCommunicationLostCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.20.5 | ScalarpcnsNetCommunicationLostCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.20.6 | ScalarpcnsNetCommunicationLostEnableShutdown | read-write | mandatory | Perform a graceful shutdown of the server when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.20.7 | ScalarpcnsNetCommunicationLostShutdownDelay | read-write | mandatory | How long to wait after event occurs before performing a graceful shutdown of the server (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.21 | NodepcnsCommunicationEstablished | |||
| 1.3.6.1.4.1.318.1.2.3.4.21.1 | ScalarpcnsCommunicationEstablishedDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.21.2 | ScalarpcnsCommunicationEstablishedEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.21.3 | ScalarpcnsCommunicationEstablishedEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.21.4 | ScalarpcnsCommunicationEstablishedCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.21.5 | ScalarpcnsCommunicationEstablishedCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.22 | NodepcnsMinRedundancyLost | |||
| 1.3.6.1.4.1.318.1.2.3.4.22.1 | ScalarpcnsMinRedundancyLostDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.22.2 | ScalarpcnsMinRedundancyLostEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.22.3 | ScalarpcnsMinRedundancyLostEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.22.4 | ScalarpcnsMinRedundancyLostCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.22.5 | ScalarpcnsMinRedundancyLostCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.22.6 | ScalarpcnsMinRedundancyLostEnableShutdown | read-write | mandatory | Perform a graceful shutdown of the server when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.22.7 | ScalarpcnsMinRedundancyLostShutdownDelay | read-write | mandatory | How long to wait after event occurs before performing a graceful shutdown of the server (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.23 | NodepcnsMinRedundancyRegained | |||
| 1.3.6.1.4.1.318.1.2.3.4.23.1 | ScalarpcnsMinRedundancyRegainedDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.23.2 | ScalarpcnsMinRedundancyRegainedEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.23.3 | ScalarpcnsMinRedundancyRegainedEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.23.4 | ScalarpcnsMinRedundancyRegainedCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.23.5 | ScalarpcnsMinRedundancyRegainedCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.24 | NodepcnsParallelRedundancyLost | |||
| 1.3.6.1.4.1.318.1.2.3.4.24.1 | ScalarpcnsParallelRedundancyLostDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.24.2 | ScalarpcnsParallelRedundancyLostEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.24.3 | ScalarpcnsParallelRedundancyLostEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.24.4 | ScalarpcnsParallelRedundancyLostCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.24.5 | ScalarpcnsParallelRedundancyLostCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.24.6 | ScalarpcnsParallelRedundancyLostEnableShutdown | read-write | mandatory | Perform a graceful shutdown of the server when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.24.7 | ScalarpcnsParallelRedundancyLostShutdownDelay | read-write | mandatory | How long to wait after event occurs before performing a graceful shutdown of the server (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.25 | NodepcnsParallelRedundancyRegained | |||
| 1.3.6.1.4.1.318.1.2.3.4.25.1 | ScalarpcnsParallelRedundancyRegainedDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.25.2 | ScalarpcnsParallelRedundancyRegainedEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.25.3 | ScalarpcnsParallelRedundancyRegainedEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.25.4 | ScalarpcnsParallelRedundancyRegainedCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.25.5 | ScalarpcnsParallelRedundancyRegainedCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.26 | NodepcnsMaxInternalTempExceeded | |||
| 1.3.6.1.4.1.318.1.2.3.4.26.1 | ScalarpcnsMaxInternalTempExceededDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.26.2 | ScalarpcnsMaxInternalTempExceededEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.26.3 | ScalarpcnsMaxInternalTempExceededEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.26.4 | ScalarpcnsMaxInternalTempExceededCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.26.5 | ScalarpcnsMaxInternalTempExceededCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.26.6 | ScalarpcnsMaxInternalTempExceededEnableShutdown | read-write | mandatory | Perform a graceful shutdown of the server when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.26.7 | ScalarpcnsMaxInternalTempExceededShutdownDelay | read-write | mandatory | How long to wait after event occurs before performing a graceful shutdown of the server (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.27 | NodepcnsMaxInternalTempInRange | |||
| 1.3.6.1.4.1.318.1.2.3.4.27.1 | ScalarpcnsMaxInternalTempInRangeDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.27.2 | ScalarpcnsMaxInternalTempInRangeEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.27.3 | ScalarpcnsMaxInternalTempInRangeEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.27.4 | ScalarpcnsMaxInternalTempInRangeCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.27.5 | ScalarpcnsMaxInternalTempInRangeCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.28 | NodepcnsMinLoadCapabilityLost | |||
| 1.3.6.1.4.1.318.1.2.3.4.28.1 | ScalarpcnsMinLoadCapabilityLostDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.28.2 | ScalarpcnsMinLoadCapabilityLostEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.28.3 | ScalarpcnsMinLoadCapabilityLostEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.28.4 | ScalarpcnsMinLoadCapabilityLostCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.28.5 | ScalarpcnsMinLoadCapabilityLostCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.28.6 | ScalarpcnsMinLoadCapabilityLostEnableShutdown | read-write | mandatory | Perform a graceful shutdown of the server when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.28.7 | ScalarpcnsMinLoadCapabilityLostShutdownDelay | read-write | mandatory | How long to wait after event occurs before performing a graceful shutdown of the server (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.29 | NodepcnsMinLoadCapabilityRegained | |||
| 1.3.6.1.4.1.318.1.2.3.4.29.1 | ScalarpcnsMinLoadCapabilityRegainedDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.29.2 | ScalarpcnsMinLoadCapabilityRegainedEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.29.3 | ScalarpcnsMinLoadCapabilityRegainedEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.29.4 | ScalarpcnsMinLoadCapabilityRegainedCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.29.5 | ScalarpcnsMinLoadCapabilityRegainedCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.30 | NodepcnsEnvironmentCommunicationEstablished | |||
| 1.3.6.1.4.1.318.1.2.3.4.30.1 | ScalarpcnsEnvironmentCommunicationEstablishedDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.30.2 | ScalarpcnsEnvironmentCommunicationEstablishedEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.30.3 | ScalarpcnsEnvironmentCommunicationEstablishedEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.30.4 | ScalarpcnsEnvironmentCommunicationEstablishedCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.30.5 | ScalarpcnsEnvironmentCommunicationEstablishedCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.31 | NodepcnsEnvironmentCommunicationLost | |||
| 1.3.6.1.4.1.318.1.2.3.4.31.1 | ScalarpcnsEnvironmentCommunicationLostDesc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.31.2 | ScalarpcnsEnvironmentCommunicationLostEnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.31.3 | ScalarpcnsEnvironmentCommunicationLostEnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.31.4 | ScalarpcnsEnvironmentCommunicationLostCommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.31.5 | ScalarpcnsEnvironmentCommunicationLostCommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.32 | NodepcnsTempInRangeProbe1 | |||
| 1.3.6.1.4.1.318.1.2.3.4.32.1 | ScalarpcnsTempInRangeProbe1Desc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.32.2 | ScalarpcnsTempInRangeProbe1EnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.32.3 | ScalarpcnsTempInRangeProbe1EnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.32.4 | ScalarpcnsTempInRangeProbe1CommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.32.5 | ScalarpcnsTempInRangeProbe1CommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.33 | NodepcnsTempOutOfRangeProbe1 | |||
| 1.3.6.1.4.1.318.1.2.3.4.33.1 | ScalarpcnsTempOutOfRangeProbe1Desc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.33.2 | ScalarpcnsTempOutOfRangeProbe1EnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.33.3 | ScalarpcnsTempOutOfRangeProbe1EnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.33.4 | ScalarpcnsTempOutOfRangeProbe1CommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.33.5 | ScalarpcnsTempOutOfRangeProbe1CommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.33.6 | ScalarpcnsTempOutOfRangeProbe1EnableShutdown | read-write | mandatory | Perform a graceful shutdown of the server when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.33.7 | ScalarpcnsTempOutOfRangeProbe1ShutdownDelay | read-write | mandatory | How long to wait after event occurs before performing a graceful shutdown of the server (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.34 | NodepcnsHumidityInRangeProbe1 | |||
| 1.3.6.1.4.1.318.1.2.3.4.34.1 | ScalarpcnsHumidityInRangeProbe1Desc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.34.2 | ScalarpcnsHumidityInRangeProbe1EnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.34.3 | ScalarpcnsHumidityInRangeProbe1EnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.34.4 | ScalarpcnsHumidityInRangeProbe1CommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.34.5 | ScalarpcnsHumidityInRangeProbe1CommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.35 | NodepcnsHumidityOutOfRangeProbe1 | |||
| 1.3.6.1.4.1.318.1.2.3.4.35.1 | ScalarpcnsHumidityOutOfRangeProbe1Desc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.35.2 | ScalarpcnsHumidityOutOfRangeProbe1EnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.35.3 | ScalarpcnsHumidityOutOfRangeProbe1EnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.35.4 | ScalarpcnsHumidityOutOfRangeProbe1CommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.35.5 | ScalarpcnsHumidityOutOfRangeProbe1CommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.35.6 | ScalarpcnsHumidityOutOfRangeProbe1EnableShutdown | read-write | mandatory | Perform a graceful shutdown of the server when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.35.7 | ScalarpcnsHumidityOutOfRangeProbe1ShutdownDelay | read-write | mandatory | How long to wait after event occurs before performing a graceful shutdown of the server (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.36 | NodepcnsTempInRangeProbe2 | |||
| 1.3.6.1.4.1.318.1.2.3.4.36.1 | ScalarpcnsTempInRangeProbe2Desc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.36.2 | ScalarpcnsTempInRangeProbe2EnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.36.3 | ScalarpcnsTempInRangeProbe2EnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.36.4 | ScalarpcnsTempInRangeProbe2CommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.36.5 | ScalarpcnsTempInRangeProbe2CommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.37 | NodepcnsTempOutOfRangeProbe2 | |||
| 1.3.6.1.4.1.318.1.2.3.4.37.1 | ScalarpcnsTempOutOfRangeProbe2Desc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.37.2 | ScalarpcnsTempOutOfRangeProbe2EnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.37.3 | ScalarpcnsTempOutOfRangeProbe2EnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.37.4 | ScalarpcnsTempOutOfRangeProbe2CommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.37.5 | ScalarpcnsTempOutOfRangeProbe2CommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.37.6 | ScalarpcnsTempOutOfRangeProbe2EnableShutdown | read-write | mandatory | Perform a graceful shutdown of the server when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.37.7 | ScalarpcnsTempOutOfRangeProbe2ShutdownDelay | read-write | mandatory | How long to wait after event occurs before performing a graceful shutdown of the server (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.38 | NodepcnsHumidityInRangeProbe2 | |||
| 1.3.6.1.4.1.318.1.2.3.4.38.1 | ScalarpcnsHumidityInRangeProbe2Desc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.38.2 | ScalarpcnsHumidityInRangeProbe2EnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.38.3 | ScalarpcnsHumidityInRangeProbe2EnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.38.4 | ScalarpcnsHumidityInRangeProbe2CommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.38.5 | ScalarpcnsHumidityInRangeProbe2CommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.39 | NodepcnsHumidityOutOfRangeProbe2 | |||
| 1.3.6.1.4.1.318.1.2.3.4.39.1 | ScalarpcnsHumidityOutOfRangeProbe2Desc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.39.2 | ScalarpcnsHumidityOutOfRangeProbe2EnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.39.3 | ScalarpcnsHumidityOutOfRangeProbe2EnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.39.4 | ScalarpcnsHumidityOutOfRangeProbe2CommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.39.5 | ScalarpcnsHumidityOutOfRangeProbe2CommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.39.6 | ScalarpcnsHumidityOutOfRangeProbe2EnableShutdown | read-write | mandatory | Perform a graceful shutdown of the server when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.39.7 | ScalarpcnsHumidityOutOfRangeProbe2ShutdownDelay | read-write | mandatory | How long to wait after event occurs before performing a graceful shutdown of the server (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.40 | NodepcnsContactFault1 | |||
| 1.3.6.1.4.1.318.1.2.3.4.40.1 | ScalarpcnsContactFault1Desc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.40.2 | ScalarpcnsContactFault1EnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.40.3 | ScalarpcnsContactFault1EnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.40.4 | ScalarpcnsContactFault1CommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.40.5 | ScalarpcnsContactFault1CommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.40.6 | ScalarpcnsContactFault1EnableShutdown | read-write | mandatory | Perform a graceful shutdown of the server when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.40.7 | ScalarpcnsContactFault1ShutdownDelay | read-write | mandatory | How long to wait after event occurs before performing a graceful shutdown of the server (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.41 | NodepcnsContactFault2 | |||
| 1.3.6.1.4.1.318.1.2.3.4.41.1 | ScalarpcnsContactFault2Desc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.41.2 | ScalarpcnsContactFault2EnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.41.3 | ScalarpcnsContactFault2EnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.41.4 | ScalarpcnsContactFault2CommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.41.5 | ScalarpcnsContactFault2CommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.41.6 | ScalarpcnsContactFault2EnableShutdown | read-write | mandatory | Perform a graceful shutdown of the server when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.41.7 | ScalarpcnsContactFault2ShutdownDelay | read-write | mandatory | How long to wait after event occurs before performing a graceful shutdown of the server (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.42 | NodepcnsContactFault3 | |||
| 1.3.6.1.4.1.318.1.2.3.4.42.1 | ScalarpcnsContactFault3Desc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.42.2 | ScalarpcnsContactFault3EnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.42.3 | ScalarpcnsContactFault3EnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.42.4 | ScalarpcnsContactFault3CommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.42.5 | ScalarpcnsContactFault3CommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.42.6 | ScalarpcnsContactFault3EnableShutdown | read-write | mandatory | Perform a graceful shutdown of the server when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.42.7 | ScalarpcnsContactFault3ShutdownDelay | read-write | mandatory | How long to wait after event occurs before performing a graceful shutdown of the server (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.43 | NodepcnsContactFault4 | |||
| 1.3.6.1.4.1.318.1.2.3.4.43.1 | ScalarpcnsContactFault4Desc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.43.2 | ScalarpcnsContactFault4EnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.43.3 | ScalarpcnsContactFault4EnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.43.4 | ScalarpcnsContactFault4CommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.43.5 | ScalarpcnsContactFault4CommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.43.6 | ScalarpcnsContactFault4EnableShutdown | read-write | mandatory | Perform a graceful shutdown of the server when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.43.7 | ScalarpcnsContactFault4ShutdownDelay | read-write | mandatory | How long to wait after event occurs before performing a graceful shutdown of the server (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.44 | NodepcnsContactNormal1 | |||
| 1.3.6.1.4.1.318.1.2.3.4.44.1 | ScalarpcnsContactNormal1Desc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.44.2 | ScalarpcnsContactNormal1EnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.44.3 | ScalarpcnsContactNormal1EnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.44.4 | ScalarpcnsContactNormal1CommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.44.5 | ScalarpcnsContactNormal1CommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.45 | NodepcnsContactNormal2 | |||
| 1.3.6.1.4.1.318.1.2.3.4.45.1 | ScalarpcnsContactNormal2Desc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.45.2 | ScalarpcnsContactNormal2EnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.45.3 | ScalarpcnsContactNormal2EnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.45.4 | ScalarpcnsContactNormal2CommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.45.5 | ScalarpcnsContactNormal2CommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.46 | NodepcnsContactNormal3 | |||
| 1.3.6.1.4.1.318.1.2.3.4.46.1 | ScalarpcnsContactNormal3Desc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.46.2 | ScalarpcnsContactNormal3EnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.46.3 | ScalarpcnsContactNormal3EnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.46.4 | ScalarpcnsContactNormal3CommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.46.5 | ScalarpcnsContactNormal3CommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.4.47 | NodepcnsContactNormal4 | |||
| 1.3.6.1.4.1.318.1.2.3.4.47.1 | ScalarpcnsContactNormal4Desc | read-only | mandatory | The Description of the event. |
| 1.3.6.1.4.1.318.1.2.3.4.47.2 | ScalarpcnsContactNormal4EnableLogging | read-write | mandatory | Log occurrences of this event in PCNS log. |
| 1.3.6.1.4.1.318.1.2.3.4.47.3 | ScalarpcnsContactNormal4EnableCommandFile | read-write | mandatory | Execute a command file when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.47.4 | ScalarpcnsContactNormal4CommandFilePath | read-write | mandatory | Path of command file to execute when this event occurs. |
| 1.3.6.1.4.1.318.1.2.3.4.47.5 | ScalarpcnsContactNormal4CommandFileDelay | read-write | mandatory | How long to wait after event occurs before executing command file (seconds). |
| 1.3.6.1.4.1.318.1.2.3.5 | NodepcnsShutdown | |||
| 1.3.6.1.4.1.318.1.2.3.5.1 | ScalarpcnsShutdownCommandFileEnabled | read-write | mandatory | Run a shutdown command file before performing graceful shutdown. |
| 1.3.6.1.4.1.318.1.2.3.5.2 | ScalarpcnsShutdownCommandFileDelay | read-write | mandatory | How long in seconds to wait before running a shutdown command file before graceful shutdown. |
| 1.3.6.1.4.1.318.1.2.3.5.3 | ScalarpcnsShutdownCommandFile | read-write | mandatory | Full name of the shutdown command file to run before graceful shutdown. |
| 1.3.6.1.4.1.318.1.2.3.5.4 | ScalarpcnsShutdownCommandFileDuration | read-write | mandatory | How long in seconds shutdown command file takes to run. |
| 1.3.6.1.4.1.318.1.2.3.5.5 | ScalarpcnsTurnOffUps | read-write | mandatory | Turn off the UPS when performing a graceful shutdown. |
| 1.3.6.1.4.1.318.1.2.3.5.6 | ScalarpcnsTurnOffSOG | read-write | mandatory | Turn off the Outlet Group on the UPS when performing a graceful shutdown. |
| 1.3.6.1.4.1.318.1.2.3.5.7 | ScalarpcnsRuntimeRemainingThreshold | read-write | mandatory | This defines a threshold for runtime remaining. When the UPS is running on battery power and the runtime remaining on the UPS drops below the threshold, PowerC… |
| 1.3.6.1.4.1.318.1.2.3.5.8 | ScalarpcnsRuntimeRemainingCmdFileThreshold | read-write | mandatory | This defines a threshold for runtime remaining. When runtime remaining drops below this threshold, PowerChute will execute the command file. |
| 1.3.6.1.4.1.318.1.2.3.5.9 | TablepcnsAdvancedShutdownTable | not-accessible | mandatory | The Network Management Cards in the UPS's which PCNS is monitoring to provide safe shutdown. |
| 1.3.6.1.4.1.318.1.2.3.5.9.1 | RowpcnsAdvancedShutdownEntry | not-accessible | mandatory | Details of the NMC. |
| 1.3.6.1.4.1.318.1.2.3.5.9.1.1 | ColumnpcnsAdvancedGroupNo | read-only | mandatory | Index of the Advanced Shutdown Group. |
| 1.3.6.1.4.1.318.1.2.3.5.9.1.2 | ColumnpcnsAdvancedGroupName | read-write | mandatory | Name of the Advanced Shutdown Group. |
| 1.3.6.1.4.1.318.1.2.3.5.9.1.3 | ColumnpcnsAdvancedGroupNMC | read-only | mandatory | List of NMCs in the Advanced Shutdown Group. |
| 1.3.6.1.4.1.318.1.2.3.5.9.1.4 | ColumnpcnsAdvancedShutdownUPSRequiredForLoad | read-write | mandatory | Number of UPS's required to power load. |
| 1.3.6.1.4.1.318.1.2.3.5.9.1.5 | ColumnpcnsAdvancedShutdownCommandFileEnabled | read-write | mandatory | Run a shutdown command file before performing graceful shutdown. |
| 1.3.6.1.4.1.318.1.2.3.5.9.1.6 | ColumnpcnsAdvancedShutdownCommandFile | read-write | mandatory | Full name of the shutdown command file to run before graceful shutdown. |
| 1.3.6.1.4.1.318.1.2.3.5.9.1.7 | ColumnpcnsAdvancedShutdownCommandFileDuration | read-write | mandatory | How long in seconds shutdown command file takes to run. |
| 1.3.6.1.4.1.318.1.2.3.5.9.1.8 | ColumnpcnsAdvancedShutdownPowerchuteServer | read-write | mandatory | Shut down PowerChute Server. |
| 1.3.6.1.4.1.318.1.2.3.5.9.1.9 | ColumnpcnsAdvancedShutdownOnLostRedundancy | read-write | mandatory | Shut down if Redundancy lost. |
| 1.3.6.1.4.1.318.1.2.3.5.9.1.10 | ColumnpcnsAdvancedTurnOffUps | read-write | mandatory | Turn off the UPS when performing a graceful shutdown. |
| 1.3.6.1.4.1.318.1.2.3.5.9.1.11 | ColumnpcnsAdvancedTurnOffSOG | read-write | mandatory | Turn off the Outlet Group on the UPS when performing a graceful shutdown. |
| 1.3.6.1.4.1.318.1.2.3.6 | NodepcnsAlarms | |||
| 1.3.6.1.4.1.318.1.2.3.6.1 | ScalarpcnsCriticalFlag | read-only | mandatory | PowerChute Network Shutdown has begun a safe shutdown of the host. |
| 1.3.6.1.4.1.318.1.2.3.6.2 | ScalarpcnsCriticalCause | read-only | mandatory | The reason PowerChute Network Shutdown has begun a safe shutdown. |
| 1.3.6.1.4.1.318.1.2.3.6.3 | ScalarpcnsNetComsLostFlag | read-only | mandatory | PowerChute cannot communicate with NMC. |
| 1.3.6.1.4.1.318.1.2.3.6.4 | ScalarpcnsNMCComsLostFlag | read-only | mandatory | NMC cannot communicate with UPS. |
| 1.3.6.1.4.1.318.1.2.3.6.5 | ScalarpcnsUpdateAvailableFlag | read-only | mandatory | PowerChute has detected that a newer version is available. |
| 1.3.6.1.4.1.318.1.2.3.6.6 | ScalarpcnsUpdateDesc | read-only | mandatory | Details of the newer version of PowerChute. |
| 1.3.6.1.4.1.318.1.2.3.7 | ScalarpcnsLoggingLevel | read-write | mandatory | Override the Root Logging level for PCNS. Possible Values: CLEAR, DEBUG |
| 1.3.6.1.4.1.318.1.2.4 | NodepowerChuteBusinessEdition | |||
| 1.3.6.1.4.1.318.1.2.4.1 | NodepcbeIdent | |||
| 1.3.6.1.4.1.318.1.2.4.1.1 | ScalarpcbeHostname | read-only | mandatory | The hostname of the PCBE instance. |
| 1.3.6.1.4.1.318.1.2.4.1.2 | ScalarpcbeVersion | read-only | mandatory | The version of PCBE installed. x.x.x |
| 1.3.6.1.4.1.318.1.2.4.1.3 | ScalarpcbeOS | read-only | mandatory | The version of OS PCBE is installed on. |
| 1.3.6.1.4.1.318.1.2.4.1.4 | ScalarpcbeJavaVersion | read-only | mandatory | The version of Java PCBE is running on. |
| 1.3.6.1.4.1.318.1.2.4.1.5 | ScalarpcbeUIProtocol | read-only | mandatory | Web Protocol used to connect to the PCBE UI. |
| 1.3.6.1.4.1.318.1.2.4.1.6 | ScalarpcbeHttpPort | read-only | mandatory | Port used for PCBE http UI. |
| 1.3.6.1.4.1.318.1.2.4.1.7 | ScalarpcbeHttpsPort | read-only | mandatory | Port used for PCBE https UI. |
| 1.3.6.1.4.1.318.1.2.4.6 | NodepcbeAlarms | |||
| 1.3.6.1.4.1.318.1.2.4.6.1 | ScalarpcbeCriticalFlag | read-only | mandatory | PowerChute Business Edition has begun a safe shutdown of the host. |
| 1.3.6.1.4.1.318.1.2.4.6.2 | ScalarpcbeCriticalCause | read-only | mandatory | The reason PowerChute Business Edition has begun a safe shutdown. |
| 1.3.6.1.4.1.318.1.2.4.6.3 | ScalarpcbeComsLostFlag | read-only | mandatory | If active (1), PowerChute cannot communicate with UPS |
| 1.3.6.1.4.1.318.1.2.4.6.5 | ScalarpcbeUpdateAvailableFlag | read-only | mandatory | PowerChute has detected that a newer version is available. |
| 1.3.6.1.4.1.318.1.2.4.6.6 | ScalarpcbeUpdateDesc | read-only | mandatory | Details of the newer version of PowerChute. |
| 1.3.6.1.4.1.318.1.3 | Nodesystem | |||
| 1.3.6.1.4.1.318.1.3.1 | NodebackUPS | |||
| 1.3.6.1.4.1.318.1.3.2 | NodesmartUPS | |||
| 1.3.6.1.4.1.318.1.3.2.1 | NodesmartUPS250 | |||
| 1.3.6.1.4.1.318.1.3.2.2 | NodesmartUPS400 | |||
| 1.3.6.1.4.1.318.1.3.2.3 | NodesmartUPS600 | |||
| 1.3.6.1.4.1.318.1.3.2.4 | NodesmartUPS900 | |||
| 1.3.6.1.4.1.318.1.3.2.5 | NodesmartUPS1250 | |||
| 1.3.6.1.4.1.318.1.3.2.6 | NodesmartUPS2000 | |||
| 1.3.6.1.4.1.318.1.3.2.7 | NodesmartUPS450 | |||
| 1.3.6.1.4.1.318.1.3.2.8 | NodesmartUPS700 | |||
| 1.3.6.1.4.1.318.1.3.2.9 | NodesmartUPS1000 | |||
| 1.3.6.1.4.1.318.1.3.2.10 | NodesmartUPS1400 | |||
| 1.3.6.1.4.1.318.1.3.2.11 | NodesmartUPS2200 | |||
| 1.3.6.1.4.1.318.1.3.2.12 | NodesmartUPS3000 | |||
| 1.3.6.1.4.1.318.1.3.2.13 | NodesmartUPS5000 | |||
| 1.3.6.1.4.1.318.1.3.2.14 | NodesmartUPS7500 | |||
| 1.3.6.1.4.1.318.1.3.2.15 | NodesmartUPS10000 | |||
| 1.3.6.1.4.1.318.1.3.2.16 | NodesmartUPS1500 | |||
| 1.3.6.1.4.1.318.1.3.2.17 | NodesmartUPS3000DSP | |||
| 1.3.6.1.4.1.318.1.3.2.18 | NodesmartUPS5000DSP | |||
| 1.3.6.1.4.1.318.1.3.2.19 | NodesmartUPS8000 | |||
| 1.3.6.1.4.1.318.1.3.3 | NodematrixUPS | |||
| 1.3.6.1.4.1.318.1.3.3.1 | NodematrixUPS3000 | |||
| 1.3.6.1.4.1.318.1.3.3.2 | NodematrixUPS5000 | |||
| 1.3.6.1.4.1.318.1.3.4 | NodemasterSwitch | |||
| 1.3.6.1.4.1.318.1.3.4.1 | NodemasterSwitchV1 | |||
| 1.3.6.1.4.1.318.1.3.4.2 | NodemasterSwitchV2 | |||
| 1.3.6.1.4.1.318.1.3.4.3 | NodemasterSwitchVM | |||
| 1.3.6.1.4.1.318.1.3.4.4 | NodemasterSwitchMSP | |||
| 1.3.6.1.4.1.318.1.3.4.5 | NodemasterSwitchrPDU | |||
| 1.3.6.1.4.1.318.1.3.4.6 | NodemasterSwitchrPDU2 | |||
| 1.3.6.1.4.1.318.1.3.4.7 | NodemasterSwitchsPDU | |||
| 1.3.6.1.4.1.318.1.3.4.8 | NodemasterSwitchrPDUB | |||
| 1.3.6.1.4.1.318.1.3.5 | NodesymmetraUPS | |||
| 1.3.6.1.4.1.318.1.3.5.1 | NodesymmetraUPS4kVA | |||
| 1.3.6.1.4.1.318.1.3.5.2 | NodesymmetraUPS8kVA | |||
| 1.3.6.1.4.1.318.1.3.5.3 | NodesymmetraUPS12kVA | |||
| 1.3.6.1.4.1.318.1.3.5.4 | NodesymmetraUPS16kVA | |||
| 1.3.6.1.4.1.318.1.3.6 | Nodedp100E | |||
| 1.3.6.1.4.1.318.1.3.7 | Nodedp300E | |||
| 1.3.6.1.4.1.318.1.3.8 | Nodemonitors | |||
| 1.3.6.1.4.1.318.1.3.8.1 | Nodeenvironmental | |||
| 1.3.6.1.4.1.318.1.3.8.2 | NodeenvironmentalMgtSystem | |||
| 1.3.6.1.4.1.318.1.3.8.3 | Nodeemu2 | |||
| 1.3.6.1.4.1.318.1.3.8.4 | Nodemem | |||
| 1.3.6.1.4.1.318.1.3.9 | NoderedundantSwitch | |||
| 1.3.6.1.4.1.318.1.3.10 | NodedcPower | |||
| 1.3.6.1.4.1.318.1.3.10.1 | Nodedm3 | |||
| 1.3.6.1.4.1.318.1.3.10.2 | Nodedcmim2 | |||
| 1.3.6.1.4.1.318.1.3.11 | NodeautomaticXferSwitch | |||
| 1.3.6.1.4.1.318.1.3.12 | NodenetLock | |||
| 1.3.6.1.4.1.318.1.3.13 | Nodesymmetra3PhaseUPS | |||
| 1.3.6.1.4.1.318.1.3.13.1 | Nodesymmetra3PhaseUPS40kVA | |||
| 1.3.6.1.4.1.318.1.3.13.2 | Nodesymmetra3PhaseUPS60kVA | |||
| 1.3.6.1.4.1.318.1.3.13.3 | Nodesymmetra3PhaseUPS80kVA | |||
| 1.3.6.1.4.1.318.1.3.13.4 | Nodesymmetra3PhaseUPS20kVA | |||
| 1.3.6.1.4.1.318.1.3.14 | NodenetworkAir | |||
| 1.3.6.1.4.1.318.1.3.14.1 | NodeairFMSeries | |||
| 1.3.6.1.4.1.318.1.3.14.2 | NoderackAirRemovalUnit | |||
| 1.3.6.1.4.1.318.1.3.14.3 | NodeairPASeries | |||
| 1.3.6.1.4.1.318.1.3.14.4 | NodeairIRSC100Series | |||
| 1.3.6.1.4.1.318.1.3.14.5 | NodeairIRRC100Series | |||
| 1.3.6.1.4.1.318.1.3.14.6 | NodeairIRRP100Series | |||
| 1.3.6.1.4.1.318.1.3.14.7 | NodeairIRRP500Series | |||
| 1.3.6.1.4.1.318.1.3.14.8 | NodeairIRRD100Series | |||
| 1.3.6.1.4.1.318.1.3.14.9 | NodeairInRoomPerimeter | |||
| 1.3.6.1.4.1.318.1.3.14.10 | NodeairACRC300Series | |||
| 1.3.6.1.4.1.318.1.3.14.11 | NodeairLESeries | |||
| 1.3.6.1.4.1.318.1.3.14.12 | NodeairIRRDU | |||
| 1.3.6.1.4.1.318.1.3.14.13 | NodeairEcoBreeze | |||
| 1.3.6.1.4.1.318.1.3.14.14 | NodeairLELSeries | |||
| 1.3.6.1.4.1.318.1.3.14.15 | NodeairACRC600Series | |||
| 1.3.6.1.4.1.318.1.3.14.16 | NodeairACRD600Series | |||
| 1.3.6.1.4.1.318.1.3.14.17 | NodeairEconomizer | |||
| 1.3.6.1.4.1.318.1.3.14.18 | NodeairTSAChillers | |||
| 1.3.6.1.4.1.318.1.3.14.19 | NodeairLEG2Series | |||
| 1.3.6.1.4.1.318.1.3.14.20 | NodeairAmico | |||
| 1.3.6.1.4.1.318.1.3.14.21 | NodeairUniflarSP | |||
| 1.3.6.1.4.1.318.1.3.14.22 | NodeairTrimChiller | |||
| 1.3.6.1.4.1.318.1.3.14.23 | NodeairACRD300Series | |||
| 1.3.6.1.4.1.318.1.3.15 | NodeinfraStruXurePDU | |||
| 1.3.6.1.4.1.318.1.3.16 | Nodeais5000UPS | |||
| 1.3.6.1.4.1.318.1.3.16.1 | Nodeais5000UPS10kVA | |||
| 1.3.6.1.4.1.318.1.3.16.2 | Nodeais5000UPS20kVA | |||
| 1.3.6.1.4.1.318.1.3.16.3 | Nodeais5000UPS30kVA | |||
| 1.3.6.1.4.1.318.1.3.16.4 | Nodeais5000UPS40kVA | |||
| 1.3.6.1.4.1.318.1.3.16.5 | Nodeais5000UPS60kVA | |||
| 1.3.6.1.4.1.318.1.3.16.6 | Nodeais5000UPS80kVA | |||
| 1.3.6.1.4.1.318.1.3.16.7 | Nodeais5000UPS100kVA | |||
| 1.3.6.1.4.1.318.1.3.17 | NodesmartUPS3Phase | |||
| 1.3.6.1.4.1.318.1.3.17.1 | NodesmartUPS3Phase10kVA | |||
| 1.3.6.1.4.1.318.1.3.17.2 | NodesmartUPS3Phase15kVA | |||
| 1.3.6.1.4.1.318.1.3.17.3 | NodesmartUPS3Phase20kVA | |||
| 1.3.6.1.4.1.318.1.3.17.4 | NodesmartUPS3Phase30kVA | |||
| 1.3.6.1.4.1.318.1.3.17.5 | NodesmartUPS3Phase40kVA | |||
| 1.3.6.1.4.1.318.1.3.18 | NodebattManager | |||
| 1.3.6.1.4.1.318.1.3.19 | NodeinfraStruXureATS | |||
| 1.3.6.1.4.1.318.1.3.20 | NodeconPortServ | |||
| 1.3.6.1.4.1.318.1.3.20.1 | NodeconPortServAP930x | |||
| 1.3.6.1.4.1.318.1.3.21 | Nodegutor | |||
| 1.3.6.1.4.1.318.1.3.21.1 | NodegutorPEW | |||
| 1.3.6.1.4.1.318.1.3.21.2 | NodegutorPDW | |||
| 1.3.6.1.4.1.318.1.3.21.3 | NodegutorWEW | |||
| 1.3.6.1.4.1.318.1.3.21.4 | NodegutorWDW | |||
| 1.3.6.1.4.1.318.1.3.21.5 | NodegutorSDC | |||
| 1.3.6.1.4.1.318.1.3.21.6 | NodegutorPXP | |||
| 1.3.6.1.4.1.318.1.3.21.7 | NodegutorPXC | |||
| 1.3.6.1.4.1.318.1.3.22 | NodeaccControl | |||
| 1.3.6.1.4.1.318.1.3.22.1 | NodeaccPX | |||
| 1.3.6.1.4.1.318.1.3.23 | NodesymmetraPX | |||
| 1.3.6.1.4.1.318.1.3.23.1 | NodesymmetraPx48kVA | |||
| 1.3.6.1.4.1.318.1.3.23.2 | NodesymmetraPx160kVA | |||
| 1.3.6.1.4.1.318.1.3.23.3 | NodesymmetraPx250kVA | |||
| 1.3.6.1.4.1.318.1.3.23.4 | NodesymmetraPx500kVA | |||
| 1.3.6.1.4.1.318.1.3.23.5 | NodesymmetraPx100kVA | |||
| 1.3.6.1.4.1.318.1.3.23.6 | NodesymmetraPxDisplay | |||
| 1.3.6.1.4.1.318.1.3.24 | NodeisxModDistribution | |||
| 1.3.6.1.4.1.318.1.3.24.1 | Nodeisx24ModuleHalfRackPdu | |||
| 1.3.6.1.4.1.318.1.3.24.2 | Nodeisx6ModuleRackPdu | |||
| 1.3.6.1.4.1.318.1.3.25 | NodeisxServers | |||
| 1.3.6.1.4.1.318.1.3.25.1 | NodeisxcBasic | |||
| 1.3.6.1.4.1.318.1.3.25.2 | NodeisxcStandard | |||
| 1.3.6.1.4.1.318.1.3.25.3 | NodeisxcEnterprise | |||
| 1.3.6.1.4.1.318.1.3.25.4 | NodeisxcVirtual | |||
| 1.3.6.1.4.1.318.1.3.27 | NodesmartUPS2 | |||
| 1.3.6.1.4.1.318.1.3.28 | Nodegalaxy | |||
| 1.3.6.1.4.1.318.1.3.28.1 | Nodegalaxy7000UPS200kVA | |||
| 1.3.6.1.4.1.318.1.3.28.2 | Nodegalaxy7000UPS250kVA | |||
| 1.3.6.1.4.1.318.1.3.28.3 | Nodegalaxy7000UPS300kVA | |||
| 1.3.6.1.4.1.318.1.3.28.4 | Nodegalaxy7000UPS400kVA | |||
| 1.3.6.1.4.1.318.1.3.28.5 | Nodegalaxy7000UPS500kVA | |||
| 1.3.6.1.4.1.318.1.3.28.6 | Nodegalaxy7000SSC800kVA | |||
| 1.3.6.1.4.1.318.1.3.28.7 | Nodegalaxy7000SSC1200kVA | |||
| 1.3.6.1.4.1.318.1.3.28.8 | Nodegalaxy7000SSC2000kVA | |||
| 1.3.6.1.4.1.318.1.3.28.9 | Nodegalaxy300UPS10kVA33 | |||
| 1.3.6.1.4.1.318.1.3.28.10 | Nodegalaxy300UPS15kVA33 | |||
| 1.3.6.1.4.1.318.1.3.28.11 | Nodegalaxy300UPS20kVA33 | |||
| 1.3.6.1.4.1.318.1.3.28.12 | Nodegalaxy300UPS30kVA33 | |||
| 1.3.6.1.4.1.318.1.3.28.13 | Nodegalaxy300UPS40kVA33 | |||
| 1.3.6.1.4.1.318.1.3.28.14 | Nodegalaxy300UPS10kVA31 | |||
| 1.3.6.1.4.1.318.1.3.28.15 | Nodegalaxy300UPS15kVA31 | |||
| 1.3.6.1.4.1.318.1.3.28.16 | Nodegalaxy300UPS20kVA31 | |||
| 1.3.6.1.4.1.318.1.3.28.17 | Nodegalaxy300UPS30kVA31 | |||
| 1.3.6.1.4.1.318.1.3.28.18 | Nodegalaxy5000UPS20KVA | |||
| 1.3.6.1.4.1.318.1.3.28.19 | Nodegalaxy5000UPS30KVA | |||
| 1.3.6.1.4.1.318.1.3.28.20 | Nodegalaxy5000UPS40KVA | |||
| 1.3.6.1.4.1.318.1.3.28.21 | Nodegalaxy5000UPS50KVA | |||
| 1.3.6.1.4.1.318.1.3.28.22 | Nodegalaxy5000UPS60KVA | |||
| 1.3.6.1.4.1.318.1.3.28.23 | Nodegalaxy5000UPS80KVA | |||
| 1.3.6.1.4.1.318.1.3.28.24 | Nodegalaxy5000UPS100KVA | |||
| 1.3.6.1.4.1.318.1.3.28.25 | Nodegalaxy5000UPS120KVA | |||
| 1.3.6.1.4.1.318.1.3.28.26 | Nodegalaxy5000UPS130KVA | |||
| 1.3.6.1.4.1.318.1.3.28.27 | Nodegalaxy5500UPS20KVA | |||
| 1.3.6.1.4.1.318.1.3.28.28 | Nodegalaxy5500UPS30KVA | |||
| 1.3.6.1.4.1.318.1.3.28.29 | Nodegalaxy5500UPS40KVA | |||
| 1.3.6.1.4.1.318.1.3.28.30 | Nodegalaxy5500UPS50KVA | |||
| 1.3.6.1.4.1.318.1.3.28.31 | Nodegalaxy5500UPS60KVA | |||
| 1.3.6.1.4.1.318.1.3.28.32 | Nodegalaxy5500UPS80KVA | |||
| 1.3.6.1.4.1.318.1.3.28.33 | Nodegalaxy5500UPS100KVA | |||
| 1.3.6.1.4.1.318.1.3.28.34 | Nodegalaxy5500UPS120KVA | |||
| 1.3.6.1.4.1.318.1.3.28.35 | Nodegalaxy5500UPS130KVA | |||
| 1.3.6.1.4.1.318.1.3.28.36 | NodegalaxyVMUPS50kVA | |||
| 1.3.6.1.4.1.318.1.3.28.37 | NodegalaxyVMUPS60kVA | |||
| 1.3.6.1.4.1.318.1.3.28.38 | NodegalaxyVMUPS80kVA | |||
| 1.3.6.1.4.1.318.1.3.28.39 | NodegalaxyVMUPS90kVA | |||
| 1.3.6.1.4.1.318.1.3.28.40 | NodegalaxyVMUPS100kVA | |||
| 1.3.6.1.4.1.318.1.3.28.41 | NodegalaxyVMUPS110kVA | |||
| 1.3.6.1.4.1.318.1.3.28.42 | NodegalaxyVMUPS120kVA | |||
| 1.3.6.1.4.1.318.1.3.28.43 | NodegalaxyVMUPS130kVA | |||
| 1.3.6.1.4.1.318.1.3.28.44 | NodegalaxyVMUPS160kVA | |||
| 1.3.6.1.4.1.318.1.3.28.45 | NodegalaxyVMUPS180kVA | |||
| 1.3.6.1.4.1.318.1.3.28.46 | NodegalaxyVMUPS200kVA | |||
| 1.3.6.1.4.1.318.1.3.28.47 | NodegalaxyVMUPS225kVA | |||
| 1.3.6.1.4.1.318.1.3.28.48 | Nodegalaxy9000UPS | |||
| 1.3.6.1.4.1.318.1.3.28.49 | Nodegalaxy9000SSC | |||
| 1.3.6.1.4.1.318.1.3.28.50 | Nodegalaxy9000UPSWithSSC | |||
| 1.3.6.1.4.1.318.1.3.28.51 | Nodegalaxy9000FreqConverter | |||
| 1.3.6.1.4.1.318.1.3.28.56 | NodegalaxyVXUPS625kVA | |||
| 1.3.6.1.4.1.318.1.3.28.57 | NodegalaxyVXUPS750kVA | |||
| 1.3.6.1.4.1.318.1.3.28.58 | NodegalaxyVXUPS1000kVA | |||
| 1.3.6.1.4.1.318.1.3.28.59 | NodegalaxyVXUPS1250kVA | |||
| 1.3.6.1.4.1.318.1.3.28.60 | NodegalaxyVXUPS1500kVA | |||
| 1.3.6.1.4.1.318.1.3.28.61 | Nodegalaxy300UPS60kVA33 | |||
| 1.3.6.1.4.1.318.1.3.28.62 | Nodegalaxy300UPS80kVA33 | |||
| 1.3.6.1.4.1.318.1.3.28.63 | NodegalaxyVXUPS500kVA | |||
| 1.3.6.1.4.1.318.1.3.28.64 | NodegalaxyVXUPS250kVA | |||
| 1.3.6.1.4.1.318.1.3.28.65 | NodegalaxyVXUPS400kVA | |||
| 1.3.6.1.4.1.318.1.3.28.66 | NodegalaxyVSUPS100kW | |||
| 1.3.6.1.4.1.318.1.3.28.67 | Nodegalaxy7000UPS160kVA | |||
| 1.3.6.1.4.1.318.1.3.28.68 | NodegalaxyVXUPS300kVA | |||
| 1.3.6.1.4.1.318.1.3.28.69 | NodegalaxyVXUPS1100kVA | |||
| 1.3.6.1.4.1.318.1.3.30 | Nodeeps | |||
| 1.3.6.1.4.1.318.1.3.30.1 | Nodeeps6000UPS | |||
| 1.3.6.1.4.1.318.1.3.30.2 | Nodeeps6000SSC | |||
| 1.3.6.1.4.1.318.1.3.30.3 | Nodeeps6000UPSWithSSC | |||
| 1.3.6.1.4.1.318.1.3.30.4 | Nodeeps6000FreqConverter | |||
| 1.3.6.1.4.1.318.1.3.30.5 | Nodeeps7000UPS | |||
| 1.3.6.1.4.1.318.1.3.30.6 | Nodeeps7000SSC | |||
| 1.3.6.1.4.1.318.1.3.30.7 | Nodeeps7000UPSWithSSC | |||
| 1.3.6.1.4.1.318.1.3.30.8 | Nodeeps7000FreqConverter | |||
| 1.3.6.1.4.1.318.1.3.30.9 | Nodeeps8000UPS | |||
| 1.3.6.1.4.1.318.1.3.30.10 | Nodeeps8000SSC | |||
| 1.3.6.1.4.1.318.1.3.30.11 | Nodeeps8000UPSWithSSC | |||
| 1.3.6.1.4.1.318.1.3.30.12 | Nodeeps8000FreqConverter | |||
| 1.3.6.1.4.1.318.1.3.31 | Nodepcns | |||
| 1.3.6.1.4.1.318.1.3.31.1 | Nodepcns4 | |||
| 1.3.6.1.4.1.318.1.3.33 | Nodepcbe | |||
| 1.3.6.1.4.1.318.1.3.33.1 | Nodepcbe9 | |||
| 1.3.6.1.4.1.318.1.3.34 | Nodepmm | |||
| 1.3.6.1.4.1.318.1.3.34.1 | Nodepmm400kVA | |||
| 1.3.6.1.4.1.318.1.3.34.2 | Nodepmm500kVA | |||
| 1.3.6.1.4.1.318.2 | Nodeapcmgmt | |||
| 1.3.6.1.4.1.318.2 | NodeupsOverload | SEVERE: The UPS has sensed a load greater than 100 percent of its rated capacity. | ||
| 1.3.6.1.4.1.318.2.1 | Nodemconfig | |||
| 1.3.6.1.4.1.318.2.1.1 | ScalarmconfigNumTrapReceivers | read-only | mandatory | The number of managers to send traps to. |
| 1.3.6.1.4.1.318.2.1.2 | TablemconfigTrapReceiverTable | not-accessible | mandatory | A list of managers to send traps to. The number of entries is given by the value of mconfigNumTrapReceivers. |
| 1.3.6.1.4.1.318.2.1.2.1 | RowmconfigTrapReceiverEntry | not-accessible | mandatory | The managers to send traps to. |
| 1.3.6.1.4.1.318.2.1.2.1.1 | ColumntrapIndex | read-only | mandatory | The index to a trap receiver entry. |
| 1.3.6.1.4.1.318.2.1.2.1.2 | ColumnreceiverAddr | read-write | mandatory | The IP address of the manager to send a trap to. |
| 1.3.6.1.4.1.318.2.1.2.1.3 | ColumncommunityString | read-write | mandatory | The community name to use in the trap when sent to the manager. |
| 1.3.6.1.4.1.318.2.1.2.1.4 | Columnseverity | read-only | obsolete | The severity threshold of traps to send to the manager. traps are labeled in severity as informational(1), warning(2), severe(3). Only traps of equal or greate… |
| 1.3.6.1.4.1.318.2.1.2.1.5 | ColumnacceptThisReceiver | read-write | mandatory | The value of yes(1) indicates that trap generation for this manager is enabled. The value of no(2) indicates that trap generation for this manager is disabled |
| 1.3.6.1.4.1.318.2.1.2.1.6 | ColumnreceiveTrapType | read-only | obsolete | Type of trap. |
| 1.3.6.1.4.1.318.2.1.3 | ScalarmconfigBOOTPEnabled | read-only | mandatory | The value of yes(1) indicates the PowerNet Adapter is configured to obtain its IP configuration parameters from a BOOTP server. The value of no(2) indicates ad… |
| 1.3.6.1.4.1.318.2.1.4 | ScalarmconfigTFTPServerIP | read-write | mandatory | The IP address of TFTP server. If mconfigBOOTPEnabled is yes(1), then this IP address is provided by BOOTP server and not allowed to be modified; otherwise, th… |
| 1.3.6.1.4.1.318.2.1.5 | ScalarnewCodeAuthentViaTFTP | read-only | mandatory | Once mcontrolRestartAgent is set to loadAndExecuteNewAgent (3), PowerNet adapter will start to load the remote image file, for authentication only, instead of … |
| 1.3.6.1.4.1.318.2.1.6 | NodemconfigClock | |||
| 1.3.6.1.4.1.318.2.1.6.1 | ScalarmconfigClockDate | read-write | mandatory | The current date in the mm/dd/yyyy format. Example: 01/01/2000. |
| 1.3.6.1.4.1.318.2.1.6.2 | ScalarmconfigClockTime | read-write | mandatory | The current time in the hh:mm:ss am/pm format. Example: 12:00:00 am. |
| 1.3.6.1.4.1.318.2.2 | Nodemcontrol | |||
| 1.3.6.1.4.1.318.2.2.1 | ScalarmcontrolRestartAgent | read-write | mandatory | Setting this OID to restartCurrentAgent (1) will restart the same SNMP agent code currently saved in flash memory. Setting this OID to loadAndExecuteNewAgent (… |
| 1.3.6.1.4.1.318.2.3 | Nodemtrapargs | |||
| 1.3.6.1.4.1.318.2.3.1 | ScalarmtrapargsInteger | read-only | mandatory | This OID allows APC traps to be sent with an integer argument that my not be defined in the APC MIB. A get of this OID will return 0. |
| 1.3.6.1.4.1.318.2.3.2 | ScalarmtrapargsIpAddress | read-only | mandatory | This OID allows APC traps to be sent with an IP address argument that my not be defined in the APC MIB. A get of this OID will return 0.0.0.0. |
| 1.3.6.1.4.1.318.2.3.3 | ScalarmtrapargsString | read-only | mandatory | This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. |
| 1.3.6.1.4.1.318.2.3.4 | ScalarmtrapargsGauge | read-only | mandatory | This OID allows APC traps to be sent with a Gauge argument that my not be defined in the APC MIB. A get of this OID will return 0. |
| 1.3.6.1.4.1.318.2.3.5 | ScalarmtrapargsTimeTicks | read-only | mandatory | This OID allows APC traps to be sent with a TimeTicks argument that my not be defined in the APC MIB. A get of this OID will return 0. |
| 1.3.6.1.4.1.318.2.3.6 | ScalarmtrapargsInteger02 | read-only | mandatory | This OID allows APC traps to be sent with an integer argument that my not be defined in the APC MIB. A get of this OID will return 0. |
| 1.3.6.1.4.1.318.2.3.7 | ScalarmtrapargsInteger03 | read-only | mandatory | This OID allows APC traps to be sent with an integer argument that my not be defined in the APC MIB. A get of this OID will return 0. |
| 1.3.6.1.4.1.318.2.3.8 | ScalarmtrapargsIpAddress02 | read-only | mandatory | This OID allows APC traps to be sent with an IP address argument that my not be defined in the APC MIB. A get of this OID will return 0.0.0.0. |
| 1.3.6.1.4.1.318.2.3.9 | ScalarmtrapargsIpAddress03 | read-only | mandatory | This OID allows APC traps to be sent with an IP address argument that my not be defined in the APC MIB. A get of this OID will return 0.0.0.0. |
| 1.3.6.1.4.1.318.2.3.10 | ScalarmtrapargsString02 | read-only | mandatory | This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. |
| 1.3.6.1.4.1.318.2.3.11 | ScalarmtrapargsString03 | read-only | mandatory | This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. |
| 1.3.6.1.4.1.318.2.3.12 | ScalarmtrapargsGauge02 | read-only | mandatory | This OID allows APC traps to be sent with a Gauge argument that my not be defined in the APC MIB. A get of this OID will return 0. |
| 1.3.6.1.4.1.318.2.3.13 | ScalarmtrapargsGauge03 | read-only | mandatory | This OID allows APC traps to be sent with a Gauge argument that my not be defined in the APC MIB. A get of this OID will return 0. |
| 1.3.6.1.4.1.318.2.3.14 | ScalarmtrapargsTimeTicks02 | read-only | mandatory | This OID allows APC traps to be sent with a TimeTicks argument that my not be defined in the APC MIB. A get of this OID will return 0. |
| 1.3.6.1.4.1.318.2.3.15 | ScalarmtrapargsTimeTicks03 | read-only | mandatory | This OID allows APC traps to be sent with a TimeTicks argument that my not be defined in the APC MIB. A get of this OID will return 0. |
| 1.3.6.1.4.1.318.2.3.16 | ScalarmtrapargsString04 | read-only | mandatory | This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. |
| 1.3.6.1.4.1.318.2.3.17 | ScalarmtrapargsString05 | read-only | mandatory | This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. |
| 1.3.6.1.4.1.318.2.3.18 | ScalarmtrapargsInteger04 | read-only | mandatory | This OID allows APC traps to be sent with an integer argument that my not be defined in the APC MIB. A get of this OID will return 0. |
| 1.3.6.1.4.1.318.2.3.19 | ScalarmtrapargsInteger05 | read-only | mandatory | This OID allows APC traps to be sent with an integer argument that my not be defined in the APC MIB. A get of this OID will return 0. |
| 1.3.6.1.4.1.318.2.3.20 | ScalarmtrapargsString06 | read-only | mandatory | This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. |
| 1.3.6.1.4.1.318.2.3.21 | ScalarmtrapargsString07 | read-only | mandatory | This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. |
| 1.3.6.1.4.1.318.2.3.22 | ScalarmtrapargsString08 | read-only | mandatory | This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. |
| 1.3.6.1.4.1.318.2.3.23 | ScalarmtrapargsOctetString | read-only | mandatory | This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. |
| 1.3.6.1.4.1.318.2.3.24 | ScalarmtrapargsOctetString02 | read-only | mandatory | This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. |
| 1.3.6.1.4.1.318.2.3.25 | ScalarmtrapargsOctetString03 | read-only | mandatory | This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. |
| 1.3.6.1.4.1.318.2.3.26 | ScalarmtrapargsOctetString04 | read-only | mandatory | This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. |
| 1.3.6.1.4.1.318.2.3.27 | ScalarmtrapargsOctetString05 | read-only | mandatory | This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. |
| 1.3.6.1.4.1.318.2.3.28 | ScalarmtrapargsOctetString06 | read-only | mandatory | This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. |
| 1.3.6.1.4.1.318.2.3.29 | ScalarmtrapargsOctetString07 | read-only | mandatory | This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. |
| 1.3.6.1.4.1.318.2.3.30 | ScalarmtrapargsOctetString08 | read-only | mandatory | This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. |
| 1.3.6.1.4.1.318.2.4 | Nodemfiletransfer | |||
| 1.3.6.1.4.1.318.2.4.1 | NodemfiletransferStatus | |||
| 1.3.6.1.4.1.318.2.4.1.1 | ScalarmfiletransferStatusLastTransferResult | read-only | deprecated | This OID has been deprecated. Once mfiletransferControlInitiateFileTransfer is set to a value other than doNotInitiateFileTransfer a file transfer of mfiletran… |
| 1.3.6.1.4.1.318.2.4.2 | NodemfiletransferConfig | |||
| 1.3.6.1.4.1.318.2.4.2.1 | NodemfiletransferConfigSettings | |||
| 1.3.6.1.4.1.318.2.4.2.1.1 | ScalarmfiletransferConfigSettingsFilename | read-write | deprecated | This OID has been deprecated. The path and name of the file to transfer using the mfiletransferControlInitiateFileTransfer OID. If the file to transfer exists … |
| 1.3.6.1.4.1.318.2.4.2.2 | NodemfiletransferConfigTFTP | |||
| 1.3.6.1.4.1.318.2.4.2.2.1 | ScalarmfiletransferConfigTFTPServerAddress | read-write | deprecated | This OID has been deprecated. The IP Address in dotted decimal notation of the TFTP server involved in the file transfer. |
| 1.3.6.1.4.1.318.2.4.2.3 | NodemfiletransferConfigFTP | |||
| 1.3.6.1.4.1.318.2.4.2.3.1 | ScalarmfiletransferConfigFTPServerAddress | read-write | deprecated | This OID has been deprecated. The IP Address in dotted decimal notation of the FTP server involved in the file transfer. |
| 1.3.6.1.4.1.318.2.4.2.3.2 | ScalarmfiletransferConfigFTPServerUser | read-write | deprecated | This OID has been deprecated. The user identification for logging into the FTP server specified with mfiletransferConfigFTPServerAddress. |
| 1.3.6.1.4.1.318.2.4.2.3.3 | ScalarmfiletransferConfigFTPServerPassword | read-write | deprecated | This OID has been deprecated. The password for logging into the FTP server specified with mfiletransferConfigFTPServerAddress. |
| 1.3.6.1.4.1.318.2.4.3 | NodemfiletransferControl | |||
| 1.3.6.1.4.1.318.2.4.3.1 | ScalarmfiletransferControlInitiateFileTransfer | read-write | deprecated | This OID has been deprecated. Setting this OID to doNotInitiateFileTransfer (1) will do nothing. Setting this OID to initiateFileTransferDownloadViaTFTP (2) wi… |
| 1.3.6.1.4.1.318.3 | NodeupsDiagnosticsFailed | SEVERE: The UPS failed its internal diagnostic self-test. | ||
| 1.3.6.1.4.1.318.4 | NodeupsDischarged | SEVERE: The UPS batteries are discharged; if utility power fails an immediate low battery condition will exist. Sufficient runtime for necessary action cannot … | ||
| 1.3.6.1.4.1.318.5 | NodeupsOnBattery | WARNING: The UPS has switched to battery backup power. | ||
| 1.3.6.1.4.1.318.6 | NodesmartBoostOn | WARNING: The UPS has enabled SmartBoost(TM). | ||
| 1.3.6.1.4.1.318.7 | NodelowBattery | SEVERE: The UPS batteries are low and will soon be exhausted. If utility power is not restored the UPS will put itself to 'sleep' and immediately cut power to … | ||
| 1.3.6.1.4.1.318.8 | NodecommunicationEstablished | INFORMATIONAL: Communication with the UPS has been established. | ||
| 1.3.6.1.4.1.318.9 | NodepowerRestored | INFORMATIONAL: Utility power has been restored. | ||
| 1.3.6.1.4.1.318.10 | NodeupsDiagnosticsPassed | INFORMATIONAL: The UPS passed its internal self-test. | ||
| 1.3.6.1.4.1.318.11 | NodereturnFromLowBattery | INFORMATIONAL: The UPS has returned from a low battery condition. | ||
| 1.3.6.1.4.1.318.12 | NodeupsTurnedOff | WARNING: The UPS has been turned 'off' by the management station. | ||
| 1.3.6.1.4.1.318.13 | NodeupsSleeping | WARNING: The UPS is entering 'sleep' mode. Power to the load will be cut off. | ||
| 1.3.6.1.4.1.318.14 | NodeupsWokeUp | INFORMATION: The UPS has returned from 'sleep' mode. Power to the load has been restored. | ||
| 1.3.6.1.4.1.318.15 | NodeupsRebootStarted | WARNING: The UPS has started its reboot sequence. The UPS will reboot itself at this time. | ||
| 1.3.6.1.4.1.318.16 | NodeupsDipSwitchChanged | WARNING: The dip switch settings on the UPS have been changed, possibly altering UPS performance. | ||
| 1.3.6.1.4.1.318.17 | NodeupsBatteryNeedsReplacement | SEVERE: The batteries of the UPS need immediate replacement. | ||
| 1.3.6.1.4.1.318.18 | NodecontactFault | SEVERE: One of the contacts on the Environmental Monitor has changed from its default position. The first variable is the contact number that is faulted. | ||
| 1.3.6.1.4.1.318.19 | NodecontactFaultResolved | INFORMATIONAL: A fault on one of the Environmental Monitor contacts has been resolved. The first variable is the contact number that has been resolved. | ||
| 1.3.6.1.4.1.318.20 | NodehardwareFailureBypass | SEVERE: UPS on bypass due to internal fault | ||
| 1.3.6.1.4.1.318.21 | NodesoftwareBypass | WARNING: UPS on bypass - user set via software or panel | ||
| 1.3.6.1.4.1.318.22 | NodeswitchedBypass | WARNING: UPS on bypass - initiated by user | ||
| 1.3.6.1.4.1.318.23 | NodereturnFromBypass | INFORMATIONAL: UPS has returned from bypass | ||
| 1.3.6.1.4.1.318.24 | NodebypassPowerSupplyFailure | SEVERE: Base module bypass power supply needs repair | ||
| 1.3.6.1.4.1.318.25 | NodebaseFanFailure | SEVERE: Base module fan needs repair | ||
| 1.3.6.1.4.1.318.26 | NodebatteryPackCommLost | SEVERE: Check installation of external battery packs signal cable | ||
| 1.3.6.1.4.1.318.27 | NodebatteryPackCommEstablished | INFORMATIONAL: UPS is communicating with the external battery packs. | ||
| 1.3.6.1.4.1.318.28 | NodecalibrationStart | INFORMATIONAL: A battery calibration test has been initiated on the UPS. | ||
| 1.3.6.1.4.1.318.29 | NoderestartAgent | INFORMATIONAL: Agent restarting as commanded by manager. | ||
| 1.3.6.1.4.1.318.30 | NodeupsTurnedOn | INFORMATIONAL: A UPS is turned on. | ||
| 1.3.6.1.4.1.318.31 | NodesmartAvrReducing | WARNING: The UPS is reducing the line voltage via SmartTrim(TM). | ||
| 1.3.6.1.4.1.318.32 | NodecodeAuthenticationDone | INFORMATIONAL: Authentication on agent code image is done. | ||
| 1.3.6.1.4.1.318.33 | NodeupsOverloadCleared | INFORMATIONAL: The overload condition has been cleared. | ||
| 1.3.6.1.4.1.318.34 | NodesmartBoostOff | INFORMATIONAL: The UPS has returned from SmartBoost(TM). | ||
| 1.3.6.1.4.1.318.35 | NodesmartAvrReducingOff | INFORMATIONAL: The UPS has returned from SmartTrim(TM). | ||
| 1.3.6.1.4.1.318.36 | NodeupsBatteryReplaced | INFORMATIONAL: A bad battery fault has been cleared. | ||
| 1.3.6.1.4.1.318.37 | NodecalibrationEnd | INFORMATIONAL: The UPS has finished calibrating. | ||
| 1.3.6.1.4.1.318.38 | NodedischargeCleared | INFORMATIONAL: A UPS discharge condition has been cleared. | ||
| 1.3.6.1.4.1.318.39 | NodegracefulShutdown | INFORMATIONAL: A graceful shutdown has been initiated. | ||
| 1.3.6.1.4.1.318.41 | NodeoutletOn | WARNING: The specified PDU outlet has turned on. If sPDUOutletControlIndex equals zero, then all outlets have turned on. | ||
| 1.3.6.1.4.1.318.42 | NodeoutletOff | WARNING: The specified PDU outlet has turned off. If sPDUOutletControlIndex equals zero, then all outlets have turned off. | ||
| 1.3.6.1.4.1.318.43 | NodeoutletReboot | WARNING: The specified PDU outlet has rebooted. If sPDUOutletControlIndex equals zero, then all outlets have rebooted. | ||
| 1.3.6.1.4.1.318.44 | NodeconfigChangeSNMP | WARNING: The SNMP configuration has been changed. | ||
| 1.3.6.1.4.1.318.45 | NodeconfigChangeOutlet | WARNING: The specified PDU outlet has changed configuration. If sPDUOutletConfigIndex equals zero, then the Master outlet has changed configuration. | ||
| 1.3.6.1.4.1.318.46 | NodeaccessViolationConsole | WARNING: Someone has attempted to login via the console with the incorrect password. | ||
| 1.3.6.1.4.1.318.47 | NodeaccessViolationHTTP | WARNING: Someone has attempted to login via HTTP with the incorrect password. | ||
| 1.3.6.1.4.1.318.48 | NodepasswordChange | WARNING: The password for the device has been changed. | ||
| 1.3.6.1.4.1.318.49 | NodebadVoltage | WARNING: The output voltage is not within acceptable range. | ||
| 1.3.6.1.4.1.318.50 | NodebadVoltageCleared | INFORMATIONAL: The output voltage has returned to an acceptable level. | ||
| 1.3.6.1.4.1.318.51 | NodechargerFailure | WARNING: The battery charger has failed. | ||
| 1.3.6.1.4.1.318.52 | NodechargerFailureCleared | INFORMATIONAL: The battery charger failure condition has been cleared. | ||
| 1.3.6.1.4.1.318.53 | NodebatteryOverTemperature | WARNING: The battery temperature threshold has been violated. | ||
| 1.3.6.1.4.1.318.54 | NodebatteryOverTemperatureCleared | INFORMATIONAL: The battery over temperature has been cleared. | ||
| 1.3.6.1.4.1.318.55 | NodesmartRelayFault | WARNING: SmartBoost(TM) or SmartTrim(TM) relay fault. | ||
| 1.3.6.1.4.1.318.56 | NodesmartRelayFaultCleared | INFORMATIONAL: SmartBoost(TM) or SmartTrim(TM) relay fault has been cleared. | ||
| 1.3.6.1.4.1.318.57 | NodehumidityThresholdViolation1 | SEVERE: Probe 1 humidity threshold violated. The first variable is the current humidity. | ||
| 1.3.6.1.4.1.318.58 | NodehumidityThresholdViolationCleared1 | INFORMATIONAL: An Environmental Monitor humidity threshold violation has been cleared on probe 1. | ||
| 1.3.6.1.4.1.318.59 | NodetemperatureThresholdViolation1 | SEVERE: An Environmental Monitor temperature threshold has been violated on probe 1. The first variable is the current temperature. | ||
| 1.3.6.1.4.1.318.60 | NodetemperatureThresholdViolationCleared1 | INFORMATIONAL: An Environmental Monitor temperature threshold violation has been cleared on probe 1. | ||
| 1.3.6.1.4.1.318.61 | NodehumidityThresholdViolation2 | SEVERE: An Environmental Monitor humidity threshold has been violated on probe 2. The first variable is the current humidity. | ||
| 1.3.6.1.4.1.318.62 | NodehumidityThresholdViolationCleared2 | INFORMATIONAL: An Environmental Monitor humidity threshold violation has been cleared on probe 2. | ||
| 1.3.6.1.4.1.318.63 | NodetemperatureThresholdViolation2 | SEVERE: An Environmental Monitor temperature threshold has been violated on probe 2. The first variable is the current temperature. | ||
| 1.3.6.1.4.1.318.64 | NodetemperatureThresholdViolationCleared2 | INFORMATIONAL: An Environmental Monitor temperature threshold violation has been cleared on probe 2. | ||
| 1.3.6.1.4.1.318.65 | NodemupsCommunicationEstablished | INFORMATIONAL: Communication with the Environmental Monitor has been established. | ||
| 1.3.6.1.4.1.318.66 | NodemupsCommunicationLost | SEVERE: Communication to the Environmental Monitor has been lost. Steps to reestablish communication are in progress. | ||
| 1.3.6.1.4.1.318.67 | NodebatteryIncrease | INFORMATIONAL: The number of batteries has increased. | ||
| 1.3.6.1.4.1.318.68 | NodebatteryDecrease | INFORMATIONAL: The number of batteries has decreased. | ||
| 1.3.6.1.4.1.318.69 | NodepowerModuleIncrease | INFORMATIONAL: The number of power modules has increased. | ||
| 1.3.6.1.4.1.318.70 | NodepowerModuleDecrease | INFORMATIONAL: The number of power modules has decreased. | ||
| 1.3.6.1.4.1.318.71 | NodeintelligenceModuleInserted | INFORMATIONAL: An intelligence module has been inserted. | ||
| 1.3.6.1.4.1.318.72 | NodeintelligenceModuleRemoved | INFORMATIONAL: An intelligence module has been removed. | ||
| 1.3.6.1.4.1.318.73 | NoderintelligenceModuleInserted | INFORMATIONAL: A redundant intelligence module has been inserted. | ||
| 1.3.6.1.4.1.318.74 | NoderintelligenceModuleRemoved | INFORMATIONAL: A redundant intelligence module has been removed. | ||
| 1.3.6.1.4.1.318.75 | NodeextBatteryFrameIncease | INFORMATIONAL: An external battery frame has been added. | ||
| 1.3.6.1.4.1.318.76 | NodeextBatteryFrameDecrease | INFORMATIONAL: An external battery frame has been removed. | ||
| 1.3.6.1.4.1.318.77 | NodeabnormalCondition | SEVERE: An abnormal condition has been detected. The first variable is the fault condition. | ||
| 1.3.6.1.4.1.318.78 | NodeabnormalConditionCleared | INFORMATIONAL: An abnormal condition has been cleared. The first variable is the fault condition. | ||
| 1.3.6.1.4.1.318.79 | NodedeviceStatusChange | INFORMATIONAL: The status of the device being monitored has changed. | ||
| 1.3.6.1.4.1.318.80 | NodenoBatteries | WARNING: The UPS has no batteries attached. | ||
| 1.3.6.1.4.1.318.81 | NodenoBatteriesCleared | INFORMATIONAL: The UPS's batteries have been attached. | ||
| 1.3.6.1.4.1.318.82 | NodeuserAdded | INFORMATIONAL: A new user has been added. | ||
| 1.3.6.1.4.1.318.83 | NodeuserDeleted | INFORMATIONAL: A user has been deleted. | ||
| 1.3.6.1.4.1.318.84 | NodeuserModified | INFORMATIONAL: A user has been modified. | ||
| 1.3.6.1.4.1.318.85 | NodemsvmCommunicationEstablished | INFORMATIONAL: Communications with the MasterSwitch VM has been established. | ||
| 1.3.6.1.4.1.318.86 | NodemsvmCommunicationLost | SEVERE: Communications with the MasterSwitch VM has been lost. | ||
| 1.3.6.1.4.1.318.87 | NodemsvmOverload | SEVERE: The MasterSwitch VM in an overload condition. | ||
| 1.3.6.1.4.1.318.88 | NodemsvmOverloadCleared | INFORMATIONAL: The overload condition on the MasterSwitch VM has been cleared. | ||
| 1.3.6.1.4.1.318.89 | NodemsvmOutletOn | INFORMATIONAL: An outlet on the MasterSwitch VM has turned on. | ||
| 1.3.6.1.4.1.318.90 | NodemsvmOutletOff | INFORMATIONAL: An outlet on the MasterSwitch VM has turned off. | ||
| 1.3.6.1.4.1.318.91 | NodemsvmDeviceConfigChange | INFORMATIONAL: A device configuration change has been made on a MasterSwitch VM. | ||
| 1.3.6.1.4.1.318.92 | NodemsvmOutletConfigChange | INFORMATIONAL: An outlet configuration change has been made on a MasterSwitch VM. | ||
| 1.3.6.1.4.1.318.93 | NodemsvmLowLoad | INFORMATIONAL: The MasterSwitch VM has violated the low load threshold. | ||
| 1.3.6.1.4.1.318.94 | NodemsvmLowLoadCleared | INFORMATIONAL: The low load condition on the MasterSwitch VM has been cleared. | ||
| 1.3.6.1.4.1.318.95 | NodemsvmNearOverload | SEVERE: The MasterSwitch VM is approaching an overload condition. | ||
| 1.3.6.1.4.1.318.96 | NodemsvmNearOverloadCleared | INFORMATIONAL: The near overload condition on the MasterSwitch VM has been cleared. | ||
| 1.3.6.1.4.1.318.97 | NodemsvmPowerSupplyStatusChange | WARNING: The power supply status of the MasterSwitch VM has changed. | ||
| 1.3.6.1.4.1.318.98 | NodemspCommunicationEstablished | INFORMATIONAL: Communications with the MasterSwitch plus has been established. | ||
| 1.3.6.1.4.1.318.99 | NodemspCommunicationLost | SEVERE: Communications with the MasterSwitch plus has been lost. | ||
| 1.3.6.1.4.1.318.100 | NodemspOutletOn | INFORMATIONAL: An outlet on the MasterSwitch plus has turned on. | ||
| 1.3.6.1.4.1.318.101 | NodemspOutletOff | INFORMATIONAL: An outlet on the MasterSwitch plus has turned off. | ||
| 1.3.6.1.4.1.318.102 | NodemspDeviceConfigChange | INFORMATIONAL: A device configuration change has been made on a MasterSwitch plus. | ||
| 1.3.6.1.4.1.318.103 | NodemspOutletConfigChange | INFORMATIONAL: An outlet configuration change has been made on a MasterSwitch plus. | ||
| 1.3.6.1.4.1.318.104 | NodersSourceSwitched | INFORMATIONAL: The Redundant Switch has switched source. The first variable is an integer representing the current source: 0=A, 1=B. The second variable is the… | ||
| 1.3.6.1.4.1.318.105 | NodersLostRedundancy | SEVERE: The Redundant Switch has lost redundancy. The first variable is an integer representing the source which is no longer available: 0=A, 1=B. The second v… | ||
| 1.3.6.1.4.1.318.106 | NodersRedundancyRestored | INFORMATIONAL: Redundancy has been restored to the Redundant Switch . The first variable is an integer representing the source which has been restored: 0=A, 1=… | ||
| 1.3.6.1.4.1.318.107 | NodersConfigChange | INFORMATIONAL: A configuration change has been made on a Redundant Switch. | ||
| 1.3.6.1.4.1.318.108 | NodersCommunicationEstablished | INFORMATIONAL: Communications with the Redundant Switch has been established. | ||
| 1.3.6.1.4.1.318.109 | NodersCommunicationLost | SEVERE: Communications with the Redundant Switch has been lost. | ||
| 1.3.6.1.4.1.318.110 | NodedcCommunicationEstablished | INFORMATIONAL: Communications with the DC power plant has been established. | ||
| 1.3.6.1.4.1.318.111 | NodedcCommunicationLost | SEVERE: Communications with the DC power plant has been lost. | ||
| 1.3.6.1.4.1.318.112 | NodedcPINChanged | INFORMATIONAL: The active PIN on the DC controller has been changed. | ||
| 1.3.6.1.4.1.318.113 | NodedcMajorAlarm | SEVERE: A Major alarm is active in the DC power plant. | ||
| 1.3.6.1.4.1.318.114 | NodedcMajorAlarmCleared | INFORMATIONAL: A Major alarm is no longer active in the DC power plant. | ||
| 1.3.6.1.4.1.318.115 | NodedcMinorAlarm | WARNING: A Minor alarm is active in the DC power plant. | ||
| 1.3.6.1.4.1.318.116 | NodedcMinorAlarmCleared | INFORMATIONAL: A Minor alarm is no longer active in the DC power plant. | ||
| 1.3.6.1.4.1.318.117 | NodedcOutputRelayOn | WARNING: An output relay for the powerplant has been activated (state changed to on). The first variable is an integer representing the output relay number tha… | ||
| 1.3.6.1.4.1.318.118 | NodedcOutputRelayOff | INFORMATIONAL: An output relay for the powerplant has been deactivated (state changed to off). The first variable is an integer representing the output relay n… | ||
| 1.3.6.1.4.1.318.119 | NodedcInputRelayOn | WARNING: An input relay for the powerplant has been activated (state changed to on). The first variable is an integer representing the input relay number that … | ||
| 1.3.6.1.4.1.318.120 | NodedcInputRelayOff | INFORMATIONAL: An input relay for the powerplant has been deactivated (state changed to off). The first variable is an integer representing the input relay num… | ||
| 1.3.6.1.4.1.318.121 | NodelogicPowerSuppliesIncreased | INFORMATIONAL: The number of system power supplies has increased. | ||
| 1.3.6.1.4.1.318.122 | NodelogicPowerSuppliesDecreased | INFORMATIONAL: The number of system power supplies has decreased. | ||
| 1.3.6.1.4.1.318.123 | NodeexternalSwitchGearClosed | INFORMATIONAL: External Switch Gear closed. | ||
| 1.3.6.1.4.1.318.124 | NodeexternalSwitchGearOpened | INFORMATIONAL: External Switch Gear opened. | ||
| 1.3.6.1.4.1.318.125 | NodegeneralDeviceEvent | INFORMATIONAL: APC Device event. | ||
| 1.3.6.1.4.1.318.126 | NodeatsSourceSwitched | INFORMATIONAL: The Automatic Transfer Switch has switched source. The first variable is an integer representing the current source: 0=A, 1=B. The second variab… | ||
| 1.3.6.1.4.1.318.127 | NodeatsLostRedundancy | SEVERE: The Automatic Transfer Switch has lost redundancy. The first variable is an integer representing the source which is no longer available: 0=A, 1=B. The… | ||
| 1.3.6.1.4.1.318.128 | NodeatsRedundancyRestored | INFORMATIONAL: Redundancy has been restored to the Automatic Transfer Switch . The first variable is an integer representing the source which has been restored… | ||
| 1.3.6.1.4.1.318.129 | NodeatsConfigChange | INFORMATIONAL: A configuration change has been made on the Automatic Transfer Switch. The first variable is an integer representing the configuration setting w… | ||
| 1.3.6.1.4.1.318.130 | NodeatsCommunicationEstablished | INFORMATIONAL: Communications with the Automatic Transfer Switch has been established. | ||
| 1.3.6.1.4.1.318.131 | NodeatsCommunicationLost | SEVERE: Communications with the Automatic Transfer Switch has been lost. | ||
| 1.3.6.1.4.1.318.132 | NodeatsOverCurrent | SEVERE: Output Current has exceeded threshold. This is same as atsOverload Trap for phase or total in case banked units | ||
| 1.3.6.1.4.1.318.133 | NodeatsOverCurrentCleared | INFORMATIONAL: Output Current has returned below threshold.This is same as atsOverloadCleared Trap for phase or total in case banked units | ||
| 1.3.6.1.4.1.318.134 | NodeatsPowerSupplyFailure | SEVERE: The Automatic Transfer Switch Power Supply has failed. The first variable is an integer representing the Power Supply which has failed: 0 = Source A 24… | ||
| 1.3.6.1.4.1.318.135 | NodeatsPowerSupplyFailureCleared | INFORMATIONAL: The Automatic Transfer Power Supply Failure Cleared. The first variable is an integer representing the Power Supply which has cleared: 0 = Sourc… | ||
| 1.3.6.1.4.1.318.136 | NodedcMainsFailAlarm | WARNING: A Mains Fail alarm is active in the DC power plant. | ||
| 1.3.6.1.4.1.318.137 | NodedcMainsFailAlarmCleared | INFORMATIONAL: Mains Fail alarm is no longer active in the DC power plant. | ||
| 1.3.6.1.4.1.318.138 | NodedcFanFailAlarm | WARNING: A Fan Fail alarm is active in the DC power plant. | ||
| 1.3.6.1.4.1.318.139 | NodedcFanFailAlarmCleared | INFORMATIONAL: A Fan Fail alarm is no longer active in the DC power plant. | ||
| 1.3.6.1.4.1.318.140 | NodedcRectifierOvertempAlarm | WARNING: Rect. Overtemp alarm is active in the power plant. | ||
| 1.3.6.1.4.1.318.141 | NodedcRectifierOvertempAlarmCleared | INFORMATIONAL: Rect. Overtemp alarm is no longer active in the power plant. | ||
| 1.3.6.1.4.1.318.142 | NodedcCurrentLimitAlarm | WARNING: A Current Limit alarm is active in the power plant. | ||
| 1.3.6.1.4.1.318.143 | NodedcCurrentLimitAlarmCleared | INFORMATIONAL: Current Limit alarm is no longer active in the power plant. | ||
| 1.3.6.1.4.1.318.144 | NodedcRectifierFailAlarm | WARNING: A Rect. Fail alarm is active in the power plant. | ||
| 1.3.6.1.4.1.318.145 | NodedcRectifierFailAlarmCleared | INFORMATIONAL: Rect. Fail alarm is no longer active in the power plant. | ||
| 1.3.6.1.4.1.318.146 | NodedcMultRectFailAlarm | WARNING: Multiple Rect. Fail alarm is active in the powerplant. | ||
| 1.3.6.1.4.1.318.147 | NodedcMultRectFailAlarmCleared | INFORMATIONAL: Multiple Rect Fail alarm is no longer active in the powerplant. | ||
| 1.3.6.1.4.1.318.148 | NodedcBatteryBreakerAlarm | WARNING: Batt. Breaker alarm is active in the power plant. | ||
| 1.3.6.1.4.1.318.149 | NodedcBatteryBreakerAlarmCleared | INFORMATIONAL: Batt. Breaker alarm is no longer active in the power plant. | ||
| 1.3.6.1.4.1.318.150 | NodedcRectifierOVPAlarm | WARNING: A Rect. OVP alarm is active in the power plant. | ||
| 1.3.6.1.4.1.318.151 | NodedcRectifierOVPAlarmCleared | INFORMATIONAL: A Rect. OVP alarm is no longer active in the power plant. | ||
| 1.3.6.1.4.1.318.152 | NodedcLVDImminentAlarm | WARNING: A LVD Imminent alarm is active in the powerplant. | ||
| 1.3.6.1.4.1.318.153 | NodedcLVDImminentAlarmCleared | INFORMATIONAL: A LVD Imminent alarm is no longer active in the powerplant. | ||
| 1.3.6.1.4.1.318.154 | NodedcFuseCBAlarm | WARNING: A Fuse/CB alarm is active in the DC power plant. | ||
| 1.3.6.1.4.1.318.155 | NodedcFuseCBAlarmCleared | INFORMATIONAL: A Fuse/CB alarm is no longer active in the DC power plant. | ||
| 1.3.6.1.4.1.318.156 | NodedcBatteryTestFail | WARNING: A Battery Test failed in the DC power plant. | ||
| 1.3.6.1.4.1.318.157 | NodedcTemperatureAlarm | WARNING: A Temperature is active in the power plant. | ||
| 1.3.6.1.4.1.318.158 | NodedcTemperatureAlarmCleared | INFORMATIONAL: A Temperature alarm is no longer active in the power plant. | ||
| 1.3.6.1.4.1.318.159 | NodedcHumidityAlarm | WARNING: A Humidity alarm is active in the DC power plant. | ||
| 1.3.6.1.4.1.318.160 | NodedcHumidityAlarmCleared | INFORMATIONAL: A Humidity alarm is no longer active in the DC power plant. | ||
| 1.3.6.1.4.1.318.161 | NodedcBBCommunicationEstablished | INFORMATIONAL: Power plant bridging board communications established. | ||
| 1.3.6.1.4.1.318.162 | NodedcBBCommunicationLost | SEVERE: Power plant bridging board communications lost. | ||
| 1.3.6.1.4.1.318.163 | NodeiemHighTempThresholdViolation | SEVERE: High temperature threshold violated on Integrated Environmental Monitor probe. The first variable is the current temperature. The second variable is th… | ||
| 1.3.6.1.4.1.318.164 | NodeiemHighTempThresholdViolationCleared | INFORMATIONAL: High temperature threshold violated on Integrated Environmental Monitor probe has been cleared. The first variable is the probe number. The seco… | ||
| 1.3.6.1.4.1.318.165 | NodeiemLowTempThresholdViolation | SEVERE: Low temperature threshold violated on integrated probe. The first variable is the current temperature. The second variable is the temperature scale. Th… | ||
| 1.3.6.1.4.1.318.166 | NodeiemLowTempThresholdViolationCleared | INFORMATIONAL: Low temperature threshold violated on integrated probe has been cleared. The first variable is the probe number. The second variable is the prob… | ||
| 1.3.6.1.4.1.318.167 | NodeiemHighHumidThresholdViolation | SEVERE: High humidity threshold violated on integrated probe. The first variable is the current humidity. The second variable is the probe number. The third va… | ||
| 1.3.6.1.4.1.318.168 | NodeiemHighHumidThresholdViolationCleared | INFORMATIONAL: High humidity threshold violated on integrated probe cleared. The first variable is the probe number. The second variable is the probe name. | ||
| 1.3.6.1.4.1.318.169 | NodeiemLowHumidThresholdViolation | SEVERE: Low humidity threshold violated on integrated probe. The first variable is the current humidity. The second variable is the probe number. The third var… | ||
| 1.3.6.1.4.1.318.170 | NodeiemLowHumidThresholdViolationCleared | INFORMATIONAL: Low humidity threshold violated on integrated probe cleared. The first variable is the probe number. The second variable is the probe name. | ||
| 1.3.6.1.4.1.318.171 | NodeiemProbeDisconnected | WARNING: The temperature/humidity probe on the Integrated Environmental Monitor has been disconnected. This trap is generated when a probe that has been in com… | ||
| 1.3.6.1.4.1.318.172 | NodeiemProbeConnected | INFORMATIONAL: The temperature/humidity probe on the Integrated Environmental Monitor has been connected. This trap is generated when the Environmental Monitor… | ||
| 1.3.6.1.4.1.318.173 | NodeiemContactFault | SEVERE: There is a contact fault on the Integrated Environmental Monitor. The first argument is the number of the contact. The second argument is the name of t… | ||
| 1.3.6.1.4.1.318.174 | NodeiemContactFaultCleared | INFORMATIONAL: The contact fault on the Integrated Environmental Monitor has been cleared. The first argument is the number of the contact. The second argument… | ||
| 1.3.6.1.4.1.318.175 | NodeiemRelayFault | SEVERE: The output relay on the Integrated Environmental Monitor has switched to the fault state. The first argument is the number of the output relay. The sec… | ||
| 1.3.6.1.4.1.318.176 | NodeiemRelayFaultCleared | INFORMATIONAL: The fault condition on the output relay on the Integrated Environmental Monitor has cleared. The first argument is the number of the output rela… | ||
| 1.3.6.1.4.1.318.177 | NodebmBatManCommEstab | INFORMATIONAL: Serial Communications Established with Battery Manager. | ||
| 1.3.6.1.4.1.318.178 | NodebmBatManCommLost | SEVERE: Serial Communications Lost with Battery Manager. | ||
| 1.3.6.1.4.1.318.179 | NodebmBatManKneeAlarm | SEVERE: Battery Voltage Knee Threshold Alarm Detected. | ||
| 1.3.6.1.4.1.318.180 | NodebmBatManKneeAlarmCleared | INFORMATIONAL: Battery Voltage Knee Threshold Alarm Cleared. | ||
| 1.3.6.1.4.1.318.181 | NodebmBatManChargerAlarm | WARNING: Charger Alarm Detected. | ||
| 1.3.6.1.4.1.318.182 | NodebmBatManChargerAlarmCleared | INFORMATIONAL: Charger Alarm Cleared. | ||
| 1.3.6.1.4.1.318.183 | NodebmBatManBatteryAlarm | WARNING: Battery Alarm Detected. | ||
| 1.3.6.1.4.1.318.184 | NodebmBatManBatteryAlarmCleared | INFORMATIONAL: Battery Alarm Cleared. | ||
| 1.3.6.1.4.1.318.185 | NodebmBatManEnvironmentAlarm | WARNING: Environment Alarm Detected. | ||
| 1.3.6.1.4.1.318.186 | NodebmBatManEnvironmentAlarmCleared | INFORMATIONAL: Environment Alarm Cleared. | ||
| 1.3.6.1.4.1.318.187 | NodebmBatManMaintenanceAlarm | INFORMATIONAL: Maintenance Alarm Detected. | ||
| 1.3.6.1.4.1.318.188 | NodebmBatManMaintenanceAlarmCleared | INFORMATIONAL: Maintenance Alarm Cleared. | ||
| 1.3.6.1.4.1.318.189 | NodepduCommunicationEstablished | INFORMATIONAL: Communication Established. The first argument is the serial number. The second argument is the device name. | ||
| 1.3.6.1.4.1.318.190 | NodepduCommunicationLost | SEVERE: Communication Lost. The first argument is the serial number. The second argument is the device name. | ||
| 1.3.6.1.4.1.318.191 | NodepduUtilityLineUndervoltage | SEVERE: Utility Line Undervoltage. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | ||
| 1.3.6.1.4.1.318.192 | NodepduUtilityLineUndervoltageCleared | INFORMATIONAL: Utility Line Undervoltage Cleared. The first argument is the serial number. The second argument is the device name. The third argument is the ph… | ||
| 1.3.6.1.4.1.318.193 | NodepduUtilityLineOvervoltage | SEVERE: Utility Line Overvoltage. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | ||
| 1.3.6.1.4.1.318.194 | NodepduUtilityLineOvervoltageCleared | INFORMATIONAL: Utility Line Overvoltage Cleared. The first argument is the serial number. The second argument is the device name. The third argument is the pha… | ||
| 1.3.6.1.4.1.318.195 | NodepduGroundOvercurrent | SEVERE: Ground Overcurrent. The first argument is the serial number. The second argument is the device name. | ||
| 1.3.6.1.4.1.318.196 | NodepduGroundOvercurrentCleared | INFORMATIONAL: Ground Overcurrent Cleared. The first argument is the serial number. The second argument is the device name. | ||
| 1.3.6.1.4.1.318.197 | NodepduCircuitPanelInputUndervoltage | SEVERE: Circuit Panel Input Undervoltage. The first argument is the serial number. The second argument is the device name. The third argument is the phase numb… | ||
| 1.3.6.1.4.1.318.198 | NodepduCircuitPanelInputUndervoltageCleared | INFORMATIONAL: Circuit Panel Input Undervoltage Cleared. The first argument is the serial number. The second argument is the device name. The third argument is… | ||
| 1.3.6.1.4.1.318.199 | NodepduCircuitPanelInputOvervoltage | SEVERE: Circuit Panel Input Overvoltage. The first argument is the serial number. The second argument is the device name. The third argument is the phase numbe… | ||
| 1.3.6.1.4.1.318.200 | NodepduCircuitPanelInputOvervoltageCleared | INFORMATIONAL: Circuit Panel Input Overvoltage Cleared. The first argument is the serial number. The second argument is the device name. The third argument is … | ||
| 1.3.6.1.4.1.318.201 | NodepduCircuitPanelInputUndercurrent | SEVERE: Circuit Panel Input Undercurrent. The first argument is the serial number. The second argument is the device name. The third argument is the phase numb… | ||
| 1.3.6.1.4.1.318.202 | NodepduCircuitPanelInputUndercurrentCleared | INFORMATIONAL: Circuit Panel Input Undercurrent Cleared. The first argument is the serial number. The second argument is the device name. The third argument is… | ||
| 1.3.6.1.4.1.318.203 | NodepduCircuitPanelInputOvercurrent | SEVERE: Circuit Panel Input Overcurrent. The first argument is the serial number. The second argument is the device name. The third argument is the phase numbe… | ||
| 1.3.6.1.4.1.318.204 | NodepduCircuitPanelInputOvercurrentCleared | INFORMATIONAL: Circuit Panel Input Overcurrent Cleared. The first argument is the serial number. The second argument is the device name. The third argument is … | ||
| 1.3.6.1.4.1.318.205 | NodepduCircuitPanelFrequencyOutOfRange | SEVERE: Circuit Panel Input Frequency Out Of Range. The first argument is the serial number. The second argument is the device name. | ||
| 1.3.6.1.4.1.318.206 | NodepduCircuitPanelFrequencyOutofRangeCleared | INFORMATIONAL: Circuit Panel Input Frequency No Longer Out Of Range. The first argument is the serial number. The second argument is the device name. | ||
| 1.3.6.1.4.1.318.207 | NodepduCircuitPanelNeutralOvercurrent | SEVERE: Circuit Panel Input Neutral Overcurrent. The first argument is the serial number. The second argument is the device name. | ||
| 1.3.6.1.4.1.318.208 | NodepduCircuitPanelNeutralOvercurrentCleared | INFORMATIONAL: Circuit Panel Input Neutral Overcurrent Cleared. The first argument is the serial number. The second argument is the device name. | ||
| 1.3.6.1.4.1.318.209 | NodepduSystemOff | SEVERE: PDU System Off. The first argument is the serial number. The second argument is the device name. | ||
| 1.3.6.1.4.1.318.210 | NodepduOnBatteryMode | SEVERE: PDU is in On Battery Mode. The first argument is the serial number. The second argument is the device name. | ||
| 1.3.6.1.4.1.318.211 | NodepduMaintenanceBypassMode | INFORMATIONAL: PDU is in Maintenance Bypass Mode. The first argument is the serial number. The second argument is the device name. | ||
| 1.3.6.1.4.1.318.212 | NodepduAtypicalBypassMode | WARNING: PDU is in Atypical Bypass Mode. The first argument is the serial number. The second argument is the device name. | ||
| 1.3.6.1.4.1.318.213 | NodepduNoPanelFeedMode | SEVERE: PDU is in No Panel Feed Mode. The first argument is the serial number. The second argument is the device name. | ||
| 1.3.6.1.4.1.318.214 | NodepduUpsOperationMode | INFORMATIONAL: PDU is in Ups Operation Mode. The first argument is the serial number. The second argument is the device name. | ||
| 1.3.6.1.4.1.318.215 | NodepduForcedBypassMode | WARNING: PDU is in Forced Bypass Mode. The first argument is the serial number. The second argument is the device name. | ||
| 1.3.6.1.4.1.318.216 | NodepduInputTransformerOverTemperature | SEVERE: Input Transformer Over Temperature. The first argument is the serial number. The second argument is the device name. | ||
| 1.3.6.1.4.1.318.217 | NodepduInputTransformerOverTemperatureCleared | INFORMATIONAL: Input Transformer Over Temperature Cleared. The first argument is the serial number. The second argument is the device name. | ||
| 1.3.6.1.4.1.318.218 | NodepduUPSInputVoltageLost | SEVERE: UPS Input Voltage phase-N Lost. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | ||
| 1.3.6.1.4.1.318.219 | NodepduUPSInputVoltageRestored | INFORMATIONAL: UPS Input Voltage phase-N Restored. The first argument is the serial number. The second argument is the device name. The third argument is the p… | ||
| 1.3.6.1.4.1.318.220 | NodepduContactFault | SEVERE: A contact closure in the PDU is in an abnormal position. The first argument is the serial number. The second argument is the device name. The third arg… | ||
| 1.3.6.1.4.1.318.221 | NodepduContactFaultCleared | INFORMATIONAL: A contact closure in the PDU is in a normal position. The first argument is the serial number. The second argument is the device name. The third… | ||
| 1.3.6.1.4.1.318.222 | NoderPDUBankPhaseLowLoad | WARNING: A bank or phase on the Rack PDU has violated the low load threshold. The first argument is the serial number. The second argument is the device name. … | ||
| 1.3.6.1.4.1.318.223 | NoderPDUBankPhaseLowLoadCleared | INFORMATIONAL: The bank or phase low load condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device … | ||
| 1.3.6.1.4.1.318.224 | NoderPDUBankPhaseNearOverload | WARNING: A bank or phase of the Rack PDU is near an overload condition. The first argument is the serial number. The second argument is the device name. The th… | ||
| 1.3.6.1.4.1.318.225 | NoderPDUBankPhaseNearOverloadCleared | INFORMATIONAL: The bank or phase near overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the de… | ||
| 1.3.6.1.4.1.318.226 | NoderPDUBankPhaseOverload | SEVERE: A bank or phase of the Rack PDU is in an overload condition. The first argument is the serial number. The second argument is the device name. The third… | ||
| 1.3.6.1.4.1.318.227 | NoderPDUBankPhaseOverloadCleared | INFORMATIONAL: The bank or phase overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device … | ||
| 1.3.6.1.4.1.318.228 | NodearuDeviceConfigChange | INFORMATIONAL: Remote ARU Device Configuration change. The first argument is the host device serial number. The second argument is the host device name. The th… | ||
| 1.3.6.1.4.1.318.229 | NodermPDUCommunicationLost | SEVERE: Communication Lost. The first argument is the serial number. The second argument is the device name. | ||
| 1.3.6.1.4.1.318.230 | NodeemsCommunicationEstablished | INFORMATIONAL: Communication Established. The first argument is the serial number. The second argument is the device name. | ||
| 1.3.6.1.4.1.318.231 | NodeemsCommunicationLost | SEVERE: Communication Lost. The first argument is the serial number. The second argument is the device name. | ||
| 1.3.6.1.4.1.318.232 | NodeemsProbeConnected | INFORMATIONAL: A probe has been connected to the EMS. The first argument is the host device serial number. The second argument is the host device name. The thi… | ||
| 1.3.6.1.4.1.318.233 | NodeemsProbeDisconnected | SEVERE: A probe has been disconnected from the EMS. The first argument is the host device serial number. The second argument is the host device name. The third… | ||
| 1.3.6.1.4.1.318.234 | NodeemsSensorConnected | INFORMATIONAL: A sensor has been connected to the EMS. The first argument is the host device serial number. The second argument is the host device name. The th… | ||
| 1.3.6.1.4.1.318.235 | NodeemsSensorDisconnected | SEVERE: A sensor has been disconnected from the EMS. The first argument is the host device serial number. The second argument is the host device name. The thir… | ||
| 1.3.6.1.4.1.318.236 | NodeemsSensorFault | SEVERE: A EMS sensor is in the fault condition. The first argument is the host device serial number. The second argument is the host device name. The third arg… | ||
| 1.3.6.1.4.1.318.237 | NodeemsSensorFaultCleared | INFORMATIONAL: A EMS sensor fault condition has cleared. The first argument is the host device serial number. The second argument is the host device name. The … | ||
| 1.3.6.1.4.1.318.238 | NodeemsBeaconConnected | INFORMATIONAL: A beacon has been connected to the EMS. The first argument is the host device serial number. The second argument is the host device name. | ||
| 1.3.6.1.4.1.318.239 | NodeemsBeaconDisconnected | SEVERE: A beacon has been disconnected from the EMS. The first argument is the host device serial number. The second argument is the host device name. | ||
| 1.3.6.1.4.1.318.240 | NodeemsBeaconOn | INFORMATIONAL: A EMS beacon has gone on. The first argument is the host device serial number. The second argument is the host device name. | ||
| 1.3.6.1.4.1.318.241 | NodeemsBeaconOff | INFORMATIONAL: A EMS beacon has gone off. The first argument is the host device serial number. The second argument is the host device name. | ||
| 1.3.6.1.4.1.318.242 | NodeemsMajorAlarm | SEVERE: A Major Alarm is present in the EMS. The first argument is the EMS serial number. The second argument is the EMS name. | ||
| 1.3.6.1.4.1.318.243 | NodeemsMajorAlarmCleared | INFORMATIONAL: A Major Alarm condition has been cleared in the EMS. The first argument is the EMS serial number. The second argument is the EMS name. | ||
| 1.3.6.1.4.1.318.244 | NodeemsMinorAlarm | SEVERE: A Minor Alarm is present in the EMS. The first argument is the EMS serial number. The second argument is the EMS name. | ||
| 1.3.6.1.4.1.318.245 | NodeemsMinorAlarmCleared | INFORMATIONAL: A Minor Alarm condition has been cleared in the EMS. The first argument is the EMS serial number. The second argument is the EMS name. | ||
| 1.3.6.1.4.1.318.246 | NodeemsOutletStateAbnormal | WARNING: An outlet on the EMS has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device na… | ||
| 1.3.6.1.4.1.318.247 | NodeemsOutletStateNormal | INFORMATIONAL: An outlet on the EMS has changed to its normal state. The first argument is the host device serial number. The second argument is the host devic… | ||
| 1.3.6.1.4.1.318.248 | NodeemsInputContactStateAbnormal | WARNING: An input contact on the EMS has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host de… | ||
| 1.3.6.1.4.1.318.249 | NodeemsInputContactStateNormal | INFORMATIONAL: An input contact on the EMS has changed to its normal state. The first argument is the host device serial number. The second argument is the hos… | ||
| 1.3.6.1.4.1.318.250 | NodeemsOutputRelayStateAbnormal | WARNING: An output relay on the EMS has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host dev… | ||
| 1.3.6.1.4.1.318.251 | NodeemsOutputRelayStateNormal | INFORMATIONAL: An output relay on the EMS has changed to its normal state. The first argument is the host device serial number. The second argument is the host… | ||
| 1.3.6.1.4.1.318.252 | NodeemsDeviceConfigChange | INFORMATIONAL: A device configuration change has been made on the EMS. The first argument is the EMS serial number. The second argument is the EMS name. | ||
| 1.3.6.1.4.1.318.253 | NodeenvHighTempThresholdViolation | SEVERE: High temperature threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The… | ||
| 1.3.6.1.4.1.318.254 | NodeenvHighTempThresholdViolationCleared | INFORMATIONAL: High temperature threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host … | ||
| 1.3.6.1.4.1.318.255 | NodeenvLowTempThresholdViolation | SEVERE: Low temperature threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The … | ||
| 1.3.6.1.4.1.318.256 | NodeenvLowTempThresholdViolationCleared | INFORMATIONAL: Low temperature threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host d… | ||
| 1.3.6.1.4.1.318.257 | NodeenvHighHumidityThresholdViolation | SEVERE: High humidity threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The th… | ||
| 1.3.6.1.4.1.318.258 | NodeenvHighHumidityThresholdViolationCleared | INFORMATIONAL: High humidity threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host dev… | ||
| 1.3.6.1.4.1.318.259 | NodeenvLowHumidityThresholdViolation | SEVERE: Low humidity threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The thi… | ||
| 1.3.6.1.4.1.318.260 | NodeenvLowHumidityThresholdViolationCleared | INFORMATIONAL: Low humidity threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host devi… | ||
| 1.3.6.1.4.1.318.266 | NoderPDUCommunicationEstablished | INFORMATIONAL: Communication with a Rack PDU has been established. The first argument is the serial number. The second argument is the device name. | ||
| 1.3.6.1.4.1.318.267 | NoderPDUCommunicationLost | SEVERE: Communication with a Rack PDU has been lost. The first argument is the serial number. The second argument is the device name. | ||
| 1.3.6.1.4.1.318.268 | NoderPDUOutletOn | INFORMATIONAL: An outlet on a Switched Rack PDU has turned on. The first argument is the serial number. The second argument is the device name. The third argum… | ||
| 1.3.6.1.4.1.318.269 | NoderPDUOutletOff | INFORMATIONAL: An outlet on a Switched Rack PDU has turned off. The first argument is the serial number. The second argument is the device name. The third argu… | ||
| 1.3.6.1.4.1.318.270 | NoderPDUDeviceConfigChange | INFORMATIONAL: A device configuration change has been made on a Rack PDU. The first argument is the serial number. The second argument is the device name. | ||
| 1.3.6.1.4.1.318.271 | NoderPDUOutletConfigChange | INFORMATIONAL: An outlet configuration change has been made on a Switched Rack PDU. The first argument is the serial number. The second argument is the device … | ||
| 1.3.6.1.4.1.318.272 | NoderPDULowLoad | WARNING: A Rack PDU has violated the low load threshold. The first argument is the serial number. The second argument is the device name. The third argument is… | ||
| 1.3.6.1.4.1.318.273 | NoderPDULowLoadCleared | INFORMATIONAL: The low load condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The thir… | ||
| 1.3.6.1.4.1.318.274 | NoderPDUNearOverload | WARNING: A Rack PDU is near an overload condition. The first argument is the serial number. The second argument is the device name. The third argument is the p… | ||
| 1.3.6.1.4.1.318.275 | NoderPDUNearOverloadCleared | INFORMATIONAL: The near overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The… | ||
| 1.3.6.1.4.1.318.276 | NoderPDUOverload | SEVERE: A Rack PDU is in an overload condition. The first argument is the serial number. The second argument is the device name. The third argument is the phas… | ||
| 1.3.6.1.4.1.318.277 | NoderPDUOverloadCleared | INFORMATIONAL: The overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The thir… | ||
| 1.3.6.1.4.1.318.278 | NoderPDUPowerSupply1Fail | SEVERE: Power Supply 1 on Rack PDU is in FAIL state. The first argument is the serial number. The second argument is the device name. | ||
| 1.3.6.1.4.1.318.279 | NoderPDUPowerSupply1Ok | INFORMATIONAL: Power Supply 1 on Rack PDU is operating normally. The first argument is the serial number. The second argument is the device name. | ||
| 1.3.6.1.4.1.318.280 | NoderPDUPowerSupply2Fail | SEVERE: Power Supply 2 on Rack PDU is in FAIL state. The first argument is the serial number. The second argument is the device name. | ||
| 1.3.6.1.4.1.318.281 | NoderPDUPowerSupply2Ok | INFORMATIONAL: Power Supply 2 on Rack PDU is operating normally. The first argument is the serial number. The second argument is the device name. | ||
| 1.3.6.1.4.1.318.282 | NoderPDUPhaseConfigChange | INFORMATIONAL: A phase configuration change has been made on a Rack PDU. The first argument is the serial number. The second argument is the device name. The t… | ||
| 1.3.6.1.4.1.318.283 | NoderPDUCancelPendingCommand | INFORMATIONAL: A cancel pending command has been made on a Switched Rack PDU. The first argument is the serial number. The second argument is the device name. … | ||
| 1.3.6.1.4.1.318.284 | NodearuAlinkCommunicationEstablished | INFORMATIONAL: Remote ARU Communication Established. The first argument is the host device serial number. The second argument is the host device name. The thir… | ||
| 1.3.6.1.4.1.318.285 | NodearuAlinkCommunicationLost | SEVERE: Remote ARU Communication Lost. The first argument is the host device serial number. The second argument is the host device name. The third argument is … | ||
| 1.3.6.1.4.1.318.286 | NodearuFanFail | SEVERE: Remote ARU Fan Fail. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU nu… | ||
| 1.3.6.1.4.1.318.287 | NodearuFanFailCleared | INFORMATIONAL: Remote ARU Fan Fail Cleared. The first argument is the host device serial number. The second argument is the host device name. The third argumen… | ||
| 1.3.6.1.4.1.318.288 | NodearuSmokeAlarm | SEVERE: Remote ARU Smoke Alarm. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU… | ||
| 1.3.6.1.4.1.318.289 | NodearuSmokeAlarmCleared | INFORMATIONAL: Remote ARU Smoke Alarm Cleared. The first argument is the host device serial number. The second argument is the host device name. The third argu… | ||
| 1.3.6.1.4.1.318.290 | NodearuHighTemperatureAlarm | WARNING: ARU Exhaust temperature has exceeded the override threshold and the ARU has increased fan speed to maintain a safe environment in the rack. The first … | ||
| 1.3.6.1.4.1.318.291 | NodearuHighTemperatureAlarmCleared | INFORMATIONAL: ARU temperature override state has been cleared. The first argument is the host device serial number. The second argument is the host device nam… | ||
| 1.3.6.1.4.1.318.292 | NodearuExhaustTemperatureAlarm | SEVERE: ARU Extreme Exhaust Temperature Alarm. The ARU is unable to control the temperature within the rack The first argument is the host device serial number… | ||
| 1.3.6.1.4.1.318.293 | NodearuExhaustTemperatureAlarmCleared | INFORMATIONAL: Remote ARU Exhaust Temperature Alarm Cleared. The first argument is the host device serial number. The second argument is the host device name. … | ||
| 1.3.6.1.4.1.318.294 | NodeenvAlinkCommunicationEstablished | INFORMATIONAL: Remote Probe Communication Established. The first argument is the host device serial number. The second argument is the host device name. The th… | ||
| 1.3.6.1.4.1.318.295 | NodeenvAlinkCommunicationLost | SEVERE: Remote Probe Communication Lost. The first argument is the host device serial number. The second argument is the host device name. The third argument i… | ||
| 1.3.6.1.4.1.318.296 | NodeemsAlinkPowerOverload | SEVERE: Alink Power Overload. The first argument is the host device serial number. The second argument is the host device name. | ||
| 1.3.6.1.4.1.318.297 | NodeemsAlinkPowerOverloadCleared | INFORMATIONAL: Alink Power Overload Cleared. The first argument is the host device serial number. The second argument is the host device name. | ||
| 1.3.6.1.4.1.318.298 | NodeupsOutletGroupTurnedOn | INFORMATIONAL: The specified Outlet Group turned on. | ||
| 1.3.6.1.4.1.318.299 | NodeupsOutletGroupTurnedOff | WARNING: The specified Outlet Group turned off. | ||
| 1.3.6.1.4.1.318.300 | NodesmwCriticalCondition | SEVERE: A Symmetra MW UPS critical condition has been detected. The first variable is the fault condition. | ||
| 1.3.6.1.4.1.318.301 | NodesmwCriticalConditionCleared | INFORMATIONAL: A Symmetra MW UPS critical condition has been cleared. The first variable is the fault condition. | ||
| 1.3.6.1.4.1.318.302 | NodesmwWarningCondition | WARNING: A Symmetra MW UPS warning condition has been detected. The first variable is the fault condition. | ||
| 1.3.6.1.4.1.318.303 | NodesmwWarningConditionCleared | WARNING: A Symmetra MW UPS warning condition has been cleared. The first variable is the fault condition. | ||
| 1.3.6.1.4.1.318.304 | NodesmwInformationalCondition | INFORMATIONAL: A Symmetra MW UPS informational condition has been detected. The first variable is the fault condition. | ||
| 1.3.6.1.4.1.318.305 | NodesmwInformationalConditionCleared | INFORMATIONAL: A Symmetra MW UPS informational condition has been cleared. The first variable is the fault condition. | ||
| 1.3.6.1.4.1.318.306 | NodeairCriticalCondition | SEVERE: An Air critical condition was detected. The first variable is the error condition text message. The second variable is the error number. | ||
| 1.3.6.1.4.1.318.307 | NodeairCriticalConditionCleared | INFORMATIONAL: An Air critical condition was cleared. The first variable is the error condition text message. The second variable is the error number. | ||
| 1.3.6.1.4.1.318.308 | NodeairWarningCondition | WARNING: An Air warning condition was detected. The first variable is the error condition text message. The second variable is the error number. | ||
| 1.3.6.1.4.1.318.309 | NodeairWarningConditionCleared | WARNING: An Air warning condition was cleared. The first variable is the error condition text message. The second variable is the error number. | ||
| 1.3.6.1.4.1.318.310 | NodeairInformationalCondition | INFORMATIONAL: An Air informational condition was detected. The first variable is the error condition text message. The second variable is the error number. | ||
| 1.3.6.1.4.1.318.311 | NodeairInformationalConditionCleared | INFORMATIONAL: An Air informational condition was cleared. The first variable is the error condition text message. The second variable is the error number. | ||
| 1.3.6.1.4.1.318.312 | NodexPDUInputVoltageLowAlarm | SEVERE: Three-phase input voltage to the device is outside the specified limits. The first argument is the host device serial number. The second argument is th… | ||
| 1.3.6.1.4.1.318.313 | NodexPDUInputVoltageLowAlarmCleared | INFORMATIONAL: Three-phase input voltage to the device is back within the specified limits. The first argument is the host device serial number. The second arg… | ||
| 1.3.6.1.4.1.318.314 | NodexPDUInputVoltageHighAlarm | SEVERE: Three-phase input voltage to the device is outside the specified limits. The first argument is the host device serial number. The second argument is th… | ||
| 1.3.6.1.4.1.318.315 | NodexPDUInputVoltageHighAlarmCleared | INFORMATIONAL: Three-phase input voltage to the device is back within the specified limits. The first argument is the host device serial number. The second arg… | ||
| 1.3.6.1.4.1.318.316 | NodexPDUBypassVoltageLowAlarm | SEVERE: Three-phase bypass input voltage to the device is outside the specified limits. The first argument is the host device serial number. The second argumen… | ||
| 1.3.6.1.4.1.318.317 | NodexPDUBypassVoltageLowAlarmCleared | INFORMATIONAL: Three-phase bypass input voltage to the device is back within the specified limits. The first argument is the host device serial number. The sec… | ||
| 1.3.6.1.4.1.318.318 | NodexPDUBypassVoltageHighAlarm | SEVERE: Three-phase bypass input voltage to the device is outside the specified limits. The first argument is the host device serial number. The second argumen… | ||
| 1.3.6.1.4.1.318.319 | NodexPDUBypassVoltageHighAlarmCleared | INFORMATIONAL: Three-phase bypass input voltage to the device is back within the specified limits. The first argument is the host device serial number. The sec… | ||
| 1.3.6.1.4.1.318.320 | NodexPDUOutputVoltageLowAlarm | SEVERE: The three-phase output voltage of the device is outside the specified limits. The first argument is the host device serial number. The second argument … | ||
| 1.3.6.1.4.1.318.321 | NodexPDUOutputVoltageLowAlarmCleared | INFORMATIONAL: The three-phase output voltage of the device is back within the specified limits. The first argument is the host device serial number. The secon… | ||
| 1.3.6.1.4.1.318.322 | NodexPDUOutputVoltageHighAlarm | SEVERE: The three-phase output voltage of the device is outside the specified limits. The first argument is the host device serial number. The second argument … | ||
| 1.3.6.1.4.1.318.323 | NodexPDUOutputVoltageHighAlarmCleared | INFORMATIONAL: The three-phase output voltage of the device is back within the specified limits. The first argument is the host device serial number. The secon… | ||
| 1.3.6.1.4.1.318.324 | NodexPDUOutputCurrentLowAlarm | SEVERE: The three-phase output load current of the device is outside the specified limits. The first argument is the host device serial number. The second argu… | ||
| 1.3.6.1.4.1.318.325 | NodexPDUOutputCurrentLowAlarmCleared | INFORMATIONAL: The three-phase output load current of the device is back within the specified limits. The first argument is the host device serial number. The … | ||
| 1.3.6.1.4.1.318.326 | NodexPDUOutputCurrentHighAlarm | SEVERE: The three-phase load current of the device is outside the specified limits. The first argument is the host device serial number. The second argument is… | ||
| 1.3.6.1.4.1.318.327 | NodexPDUOutputCurrentHighAlarmCleared | INFORMATIONAL: The three-phase output current of the device is back within the specified limits. The first argument is the host device serial number. The secon… | ||
| 1.3.6.1.4.1.318.328 | NodexPDUOutputFrequencyAlarm | SEVERE: The devices output frequency is outside the specified limits. The first argument is the host device serial number. The second argument is the host devi… | ||
| 1.3.6.1.4.1.318.329 | NodexPDUOutputFrequencyAlarmCleared | INFORMATIONAL: The devices output frequency is back within the specified limits. The first argument is the host device serial number. The second argument is th… | ||
| 1.3.6.1.4.1.318.330 | NodexPDUSystemGroundCurrentAlarm | SEVERE: The earth ground current of the device is over the specified limits. The first argument is the host device serial number. The second argument is the ho… | ||
| 1.3.6.1.4.1.318.331 | NodexPDUSystemGroundCurrentAlarmCleared | INFORMATIONAL: The earth ground current of the device is back within the specified limits. The first argument is the host device serial number. The second argu… | ||
| 1.3.6.1.4.1.318.332 | NodexPDUInputContactStateAbnormal | SEVERE: A user input contact on the device has changed to its abnormal state. The first argument is the host device serial number. The second argument is the h… | ||
| 1.3.6.1.4.1.318.333 | NodexPDUInputContactStateNormal | INFORMATIONAL: A user input contact on the device has changed to its normal state. The first argument is the host device serial number. The second argument is … | ||
| 1.3.6.1.4.1.318.334 | NodexPDUOutputNeutralCurrentHighAlarm | WARNING: The three-phase neutral current of the device is outside the specified limits. The first argument is the host device serial number. The second argumen… | ||
| 1.3.6.1.4.1.318.335 | NodexPDUOutputNeutralCurrentHighAlarmCleared | INFORMATIONAL: The output neutral current of the device is back within the specified limits. The first argument is the host device serial number. The second ar… | ||
| 1.3.6.1.4.1.318.336 | NodexPDUCoolingFanAlarm | SEVERE: The device's internal cooling fans have failed. The first argument is the host device serial number. The second argument is the host device name. | ||
| 1.3.6.1.4.1.318.337 | NodexPDUCoolingFanAlarmCleared | INFORMATIONAL: The device's cooling fans are now functioning properly. The first argument is the host device serial number. The second argument is the host dev… | ||
| 1.3.6.1.4.1.318.338 | NodexPDUTransformerTempAlarm | SEVERE: The device's isolation transformer is over temperature. The first argument is the host device serial number. The second argument is the host device nam… | ||
| 1.3.6.1.4.1.318.339 | NodexPDUTransformerTempAlarmCleared | INFORMATIONAL: The device's isolation transformer is no longer over temperature. The first argument is the host device serial number. The second argument is th… | ||
| 1.3.6.1.4.1.318.340 | NodexPDUBranchCurrentLowAlarm | WARNING: The current in a branch circuit is outside the limits specified for that branch circuit. The first argument is the host device serial number. The seco… | ||
| 1.3.6.1.4.1.318.341 | NodexPDUBranchCurrentLowAlarmCleared | INFORMATIONAL: The current in a branch circuit is back within the limits specified for that branch circuit. The first argument is the host device serial number… | ||
| 1.3.6.1.4.1.318.342 | NodexPDUBranchCurrentHighAlarm | WARNING: The current in a branch circuit is outside the limits specified for that branch circuit. The first argument is the host device serial number. The seco… | ||
| 1.3.6.1.4.1.318.343 | NodexPDUBranchCurrentHighAlarmCleared | INFORMATIONAL: The current in a branch circuit is back within the limits specified for that branch circuit. The first argument is the host device serial number… | ||
| 1.3.6.1.4.1.318.344 | NodexPDUInternalCommError | SEVERE: There is an internal communication error in the device. The first argument is the host device serial number. The second argument is the host device nam… | ||
| 1.3.6.1.4.1.318.345 | NodeemsHardwareStateAbnormal | SEVERE: The device's hardware is improperly configured and operating outside normal bounds for the hardware. This can be caused by improper devices being conne… | ||
| 1.3.6.1.4.1.318.346 | NodeemsHardwareStateNormal | INFORMATIONAL: The device's hardware is in its normal operational state. The first argument is the host device serial number. | ||
| 1.3.6.1.4.1.318.347 | NodeceSevereCondition | SEVERE: A Custom Event severe condition was detected. The first variable is the custom event text message. The second variable is the custom event number. | ||
| 1.3.6.1.4.1.318.348 | NodeceSevereConditionCleared | INFORMATIONAL: A Custom Event severe condition was cleared. The first variable is the custom event text message. The second variable is the custom event number. | ||
| 1.3.6.1.4.1.318.349 | NodeceWarningCondition | WARNING: A Custom Event warning condition was detected. The first variable is the custom event text message. The second variable is the custom event number. | ||
| 1.3.6.1.4.1.318.350 | NodeceWarningConditionCleared | INFORMATIONAL: A Custom Event warning condition was cleared. The first variable is the custom event text message. The second variable is the custom event numbe… | ||
| 1.3.6.1.4.1.318.351 | NodeceInformationalCondition | INFORMATIONAL: A Custom Event informational condition was detected. The first variable is the custom event text message. The second variable is the custom even… | ||
| 1.3.6.1.4.1.318.352 | NodeceInformationalConditionCleared | INFORMATIONAL: A Custom Event informational condition was cleared. The first variable is the custom event text message. The second variable is the custom event… | ||
| 1.3.6.1.4.1.318.353 | NodeupsInternalOverTemperature | WARNING: The internal over temperature condition exists. | ||
| 1.3.6.1.4.1.318.354 | NodeupsInternalOverTemperatureCleared | INFORMATIONAL: The internal over temperature condition cleared. | ||
| 1.3.6.1.4.1.318.355 | NodeupsMpuReset | INFORMATIONAL: The MPU has been reset. | ||
| 1.3.6.1.4.1.318.356 | NodeupsOutputSwitchClosed | INFORMATIONAL: The Output Switch is closed. | ||
| 1.3.6.1.4.1.318.357 | NodeupsOutputSwitchOpened | INFORMATIONAL: The Output Switch is open. | ||
| 1.3.6.1.4.1.318.358 | NodeupsCalibrationStackChanged | INFORMATIONAL: A calibration value in the stack was changed. | ||
| 1.3.6.1.4.1.318.359 | NodeenvMaxTempThresholdViolation | SEVERE: Max temperature threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The … | ||
| 1.3.6.1.4.1.318.360 | NodeenvMaxTempThresholdViolationCleared | INFORMATIONAL: Max temperature threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host d… | ||
| 1.3.6.1.4.1.318.361 | NodeenvMinTempThresholdViolation | SEVERE: Min temperature threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The … | ||
| 1.3.6.1.4.1.318.362 | NodeenvMinTempThresholdViolationCleared | INFORMATIONAL: Min temperature threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host d… | ||
| 1.3.6.1.4.1.318.363 | NodeenvMaxHumidityThresholdViolation | SEVERE: Max humidity threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The thi… | ||
| 1.3.6.1.4.1.318.364 | NodeenvMaxHumidityThresholdViolationCleared | INFORMATIONAL: Max humidity threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host devi… | ||
| 1.3.6.1.4.1.318.365 | NodeenvMinHumidityThresholdViolation | SEVERE: Min humidity threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The thi… | ||
| 1.3.6.1.4.1.318.366 | NodeenvMinHumidityThresholdViolationCleared | INFORMATIONAL: Min humidity threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host devi… | ||
| 1.3.6.1.4.1.318.367 | NodeenvSTIncTempRateViolation | SEVERE: Short-term increasing temperature rate violated on the probe. The first argument is the host device serial number. The second argument is the host devi… | ||
| 1.3.6.1.4.1.318.368 | NodeenvSTIncTempRateViolationCleared | INFORMATIONAL: Short-term increasing temperature rate cleared on the probe. The first argument is the host device serial number. The second argument is the hos… | ||
| 1.3.6.1.4.1.318.369 | NodeenvSTDecTempRateViolation | SEVERE: Short-term decreasing temperature rate violated on the probe. The first argument is the host device serial number. The second argument is the host devi… | ||
| 1.3.6.1.4.1.318.370 | NodeenvSTDecTempRateViolationCleared | INFORMATIONAL: Short-term decreasing temperature rate cleared on the probe. The first argument is the host device serial number. The second argument is the hos… | ||
| 1.3.6.1.4.1.318.371 | NodeenvLTIncTempRateViolation | SEVERE: Long-term increasing temperature rate violated on the probe. The first argument is the host device serial number. The second argument is the host devic… | ||
| 1.3.6.1.4.1.318.372 | NodeenvLTIncTempRateViolationCleared | INFORMATIONAL: Long-term increasing temperature rate cleared on the probe. The first argument is the host device serial number. The second argument is the host… | ||
| 1.3.6.1.4.1.318.373 | NodeenvLTDecTempRateViolation | SEVERE: Long-term decreasing temperature rate violated on the probe. The first argument is the host device serial number. The second argument is the host devic… | ||
| 1.3.6.1.4.1.318.374 | NodeenvLTDecTempRateViolationCleared | INFORMATIONAL: Long-term decreasing temperature rate cleared on the probe. The first argument is the host device serial number. The second argument is the host… | ||
| 1.3.6.1.4.1.318.375 | NodebmsCriticalCondition | SEVERE: A Battery Management System critical condition was detected. The first variable is the error condition text message. The second variable is the error n… | ||
| 1.3.6.1.4.1.318.376 | NodebmsCriticalConditionCleared | INFORMATIONAL: A Battery Management System critical condition was cleared. The first variable is the error condition text message. The second variable is the e… | ||
| 1.3.6.1.4.1.318.377 | NodebmsWarningCondition | WARNING: A Battery Management System warning condition was detected. The first variable is the error condition text message. The second variable is the error n… | ||
| 1.3.6.1.4.1.318.378 | NodebmsWarningConditionCleared | WARNING: A Battery Management System warning condition was cleared. The first variable is the error condition text message. The second variable is the error nu… | ||
| 1.3.6.1.4.1.318.379 | NodebmsInformationalCondition | INFORMATIONAL: A Battery Management System informational condition was detected. The first variable is the error condition text message. The second variable is… | ||
| 1.3.6.1.4.1.318.380 | NodebmsInformationalConditionCleared | INFORMATIONAL: A Battery Management System informational condition was cleared. The first variable is the error condition text message. The second variable is … | ||
| 1.3.6.1.4.1.318.381 | NodexATSOutputVoltageLowAlarm | SEVERE: The device three-phase output voltage of the device is outside the specified limits. The first argument is the host device serial number. The second ar… | ||
| 1.3.6.1.4.1.318.382 | NodexATSOutputVoltageLowAlarmCleared | INFORMATIONAL: The devices three-phase output voltage is back within the specified limits. The first argument is the host device serial number. The second argu… | ||
| 1.3.6.1.4.1.318.383 | NodexATSOutputVoltageHighAlarm | SEVERE: The device three-phase output voltage of the device is outside the specified limits. The first argument is the host device serial number. The second ar… | ||
| 1.3.6.1.4.1.318.384 | NodexATSOutputVoltageHighAlarmCleared | INFORMATIONAL: The devices three-phase output voltage is back within the specified limits. The first argument is the host device serial number. The second argu… | ||
| 1.3.6.1.4.1.318.385 | NodexATSOutputCurrentLowAlarm | SEVERE: The three-phase load current of the device is outside the specified limits. The first argument is the host device serial number. The second argument is… | ||
| 1.3.6.1.4.1.318.386 | NodexATSOutputCurrentLowAlarmCleared | INFORMATIONAL: The three-phase load current of the device is back within the specified limits. The first argument is the host device serial number. The second … | ||
| 1.3.6.1.4.1.318.387 | NodexATSOutputCurrentHighAlarm | SEVERE: The three-phase output load current of the device is outside the specified limits. The first argument is the host device serial number. The second argu… | ||
| 1.3.6.1.4.1.318.388 | NodexATSOutputCurrentHighAlarmCleared | INFORMATIONAL: The three-phase output load current of the device is back within the specified limits. The first argument is the host device serial number. The … | ||
| 1.3.6.1.4.1.318.389 | NodexATSOutputFrequencyAlarm | SEVERE: The devices output frequency is outside the specified limits. The first argument is the host device serial number. The second argument is the host devi… | ||
| 1.3.6.1.4.1.318.390 | NodexATSOutputFrequencyAlarmCleared | INFORMATIONAL: The devices output frequency is back within the specified limits. The first argument is the host device serial number. The second argument is th… | ||
| 1.3.6.1.4.1.318.391 | NodexATSInternalCommError | SEVERE: There is an internal communication error in the device. The first argument is the host device serial number. The second argument is the host device nam… | ||
| 1.3.6.1.4.1.318.392 | NodexATSInternalCommErrorCleared | INFORMATIONAL: Internal communication has been restored. The first argument is the host device serial number. The second argument is the host device name. | ||
| 1.3.6.1.4.1.318.393 | NodexATSDataCommMismatchError | SEVERE: A data incompatibility exists within the device. This is typically the result of mismatches between firmware revisions of the transfer switch controlle… | ||
| 1.3.6.1.4.1.318.394 | NodexATSDataCommMismatchErrorCleared | INFORMATIONAL: The internal data incompatibility has been resolved. The first argument is the host device serial number. The second argument is the host device… | ||
| 1.3.6.1.4.1.318.395 | NodexATSGenCommLost | WARNING: The XATS cannot communicate with the generator. This will make unavailable all the xATSGenerator OIDs. The first argument is the host device serial nu… | ||
| 1.3.6.1.4.1.318.396 | NodexATSGenCommEstablished | INFORMATIONAL: The XATS has established communication with the generator. The first argument is the host device serial number. The second argument is the host … | ||
| 1.3.6.1.4.1.318.397 | NodexATSNeutralPosition | WARNING: XATS has transferred to neutral position. In this position neither Source 1 nor Source 2 is selected, and the XATS will have no output voltage. The fi… | ||
| 1.3.6.1.4.1.318.398 | NodexATSSwitchTransferEvent | INFORMATIONAL: XATS has transferred from one source to the other. The first argument is the host device serial number. The second argument is the host device n… | ||
| 1.3.6.1.4.1.318.399 | NodexATSInternalATSFault | SEVERE: An internal XATS fault has been detected. The XATS may have forced itself to not-in-auto mode (abnormal condition), as indicated by the xATSSwitchStatu… | ||
| 1.3.6.1.4.1.318.400 | NodexATSInternalATSFaultCleared | INFORMATIONAL: The detected internal XATS fault has been cleared. The first argument is the host device serial number. The second argument is the host device n… | ||
| 1.3.6.1.4.1.318.401 | NodexATSEngineStartAsserted | INFORMATIONAL: The XATS has asserted the Engine Start contact. This should result in the generator producing output voltage. The first argument is the host dev… | ||
| 1.3.6.1.4.1.318.402 | NodexATSEngineStopAsserted | INFORMATIONAL: The XATS has de-asserted the Engine Start contact. This should result in the generator shutting down, and producing no output voltage. The first… | ||
| 1.3.6.1.4.1.318.403 | NodexATSStartFailure | SEVERE: The generator failed to start. After assertion of the Engine Start signal, the quality of Source 2 was not seen as good. This alarm can be cleared usin… | ||
| 1.3.6.1.4.1.318.404 | NodexATSStopFailure | WARNING: The generator failed to stop. After de-assertion of the Engine Start signal, the quality of Source 2 continued to be seen as good. This alarm can be c… | ||
| 1.3.6.1.4.1.318.405 | NodexATSNotInAutomaticMode | SEVERE: Automatic Transfer Switch is not in automatic mode. The first argument is the host device serial number. The second argument is the host device name. T… | ||
| 1.3.6.1.4.1.318.406 | NodexATSNotInAutomaticModeCleared | INFORMATIONAL: Automatic Transfer Switch is in automatic mode. The first argument is the host device serial number. The second argument is the host device name. | ||
| 1.3.6.1.4.1.318.407 | NodexATSEpoTripped | SEVERE: The device's Emergency Power Off (EPO) circuit is tripped. The first argument is the host device serial number. The second argument is the host device … | ||
| 1.3.6.1.4.1.318.408 | NodexATSEpoReset | INFORMATIONAL: The device's Emergency Power Off (EPO) circuit has been reset to the armed position. The first argument is the host device serial number. The se… | ||
| 1.3.6.1.4.1.318.409 | NodexATSEpoTestMode | WARNING: The device's Emergency Power Off (EPO) circuit has been switched back to the test position. The first argument is the host device serial number. The s… | ||
| 1.3.6.1.4.1.318.410 | NodexATSEpoArmed | INFORMATIONAL: The device's Emergency Power Off (EPO) circuit has been switched back to the armed position. The first argument is the host device serial number… | ||
| 1.3.6.1.4.1.318.411 | NodexATSTestInitiated | INFORMATIONAL: A scheduled test has been initiated. The first argument is the host device serial number. The second argument is the host device name. The third… | ||
| 1.3.6.1.4.1.318.412 | NodexATSTestCanceled | INFORMATIONAL: The scheduled test has been canceled The first argument is the host device serial number. The second argument is the host device name. The third… | ||
| 1.3.6.1.4.1.318.413 | NodexATSTestFailed | SEVERE: The initiated test has failed. This alarm can be cleared using the xATSSwitchStatusClearLatchedAlarms OID. The first argument is the host device serial… | ||
| 1.3.6.1.4.1.318.414 | NodexATSTestPassed | INFORMATIONAL: The initiated test has passed switched back to the armed position. The first argument is the host device serial number. The second argument is t… | ||
| 1.3.6.1.4.1.318.415 | NodexATSInputContactStateAbnormal | SEVERE: A user input contact on the device has changed to its abnormal state. The first argument is the host device serial number. The second argument is the h… | ||
| 1.3.6.1.4.1.318.416 | NodexATSInputContactStateNormal | INFORMATIONAL: A user input contact on the device has changed to its normal state. The first argument is the host device serial number. The second argument is … | ||
| 1.3.6.1.4.1.318.417 | NodexATSRemoteStartContactMismatch | SEVERE: The state of the generator's Remote Start input and the ATS's Engine Start output do not match. This indicates something wrong in the Engine Start wiri… | ||
| 1.3.6.1.4.1.318.418 | NodexATSRemoteStartContactMismatchCleared | INFORMATIONAL: Mismatch in the state of the generator's Remote Start input and the ATS's Engine Start output as been resolved. This indicates something wrong i… | ||
| 1.3.6.1.4.1.318.419 | NodexATSDoorOpenAlarm | WARNING: The XATS exterior panel door is open. The first argument is the host device serial number. The second argument is the host device name. | ||
| 1.3.6.1.4.1.318.420 | NodexATSDoorOpenAlarmCleared | INFORMATIONAL: The external door to the device is closed. The first argument is the host device serial number. The second argument is the host device name. | ||
| 1.3.6.1.4.1.318.421 | NodexATSDCBackupAlarm | WARNING: The XATS's DC backup has been lost. The XATS will lose power on Source 1 failure, causing the Engine Start signal to be asserted. The XATS will then r… | ||
| 1.3.6.1.4.1.318.422 | NodexATSDCBackupAlarmCleared | INFORMATIONAL: DC backup alarm has been cleared in the device. The first argument is the host device serial number. The second argument is the host device name. | ||
| 1.3.6.1.4.1.318.423 | NodexATSGeneratorLowCoolantLevelAlarm | SEVERE: Low coolant level has been detected in the generator. The first argument is the host device serial number. The second argument is the host device name.… | ||
| 1.3.6.1.4.1.318.424 | NodexATSGeneratorLowCoolantLevelAlarmCleared | INFORMATIONAL: The detected low coolant level has been cleared in the generator. The first argument is the host device serial number. The second argument is th… | ||
| 1.3.6.1.4.1.318.425 | NodexATSGeneratorVeryLowCoolantLevelAlarm | SEVERE: Very low coolant level has been detected in the generator. The first argument is the host device serial number. The second argument is the host device … | ||
| 1.3.6.1.4.1.318.426 | NodexATSGeneratorVeryLowCoolantLevelAlarmCleared | INFORMATIONAL: The detected Very low coolant level has been cleared in the generator. The first argument is the host device serial number. The second argument … | ||
| 1.3.6.1.4.1.318.427 | NodexATSGeneratorHighCoolantTempAlarm | SEVERE: High coolant temperature has been detected in the generator. The first argument is the host device serial number. The second argument is the host devic… | ||
| 1.3.6.1.4.1.318.428 | NodexATSGeneratorHighCoolantTempAlarmCleared | INFORMATIONAL: The detected high coolant temperature has been cleared in the generator. The first argument is the host device serial number. The second argumen… | ||
| 1.3.6.1.4.1.318.429 | NodexATSGeneratorVeryHighCoolantTempAlarm | SEVERE: Very high coolant temperature has been detected in the generator. The first argument is the host device serial number. The second argument is the host … | ||
| 1.3.6.1.4.1.318.430 | NodexATSGeneratorVeryHighCoolantTempAlarmCleared | INFORMATIONAL: The Very high coolant temperature condition has been cleared in the generator. The first argument is the host device serial number. The second a… | ||
| 1.3.6.1.4.1.318.431 | NodexATSGeneratorLowCoolantTempAlarm | WARNING: Low coolant temperature has been detected in the generator. The first argument is the host device serial number. The second argument is the host devic… | ||
| 1.3.6.1.4.1.318.432 | NodexATSGeneratorLowCoolantTempAlarmCleared | INFORMATIONAL: The low coolant temperature condition has been cleared in the generator. The first argument is the host device serial number. The second argumen… | ||
| 1.3.6.1.4.1.318.433 | NodexATSGeneratorLowOilLevelAlarm | SEVERE: Low oil level has been detected in the generator. The first argument is the host device serial number. The second argument is the host device name. The… | ||
| 1.3.6.1.4.1.318.434 | NodexATSGeneratorLowOilLevelAlarmCleared | INFORMATIONAL: Low oil level alarm has been cleared in the generator. The first argument is the host device serial number. The second argument is the host devi… | ||
| 1.3.6.1.4.1.318.435 | NodexATSGeneratorLowBatteryVoltDuringCrankAlarm | SEVERE: The generator's battery voltage has been detected as low while cranking the engine. The first argument is the host device serial number. The second arg… | ||
| 1.3.6.1.4.1.318.436 | NodexATSGeneratorLowBatteryVoltDuringCrankAlarmCleared | INFORMATIONAL: The generator's low battery voltage while cranking condition has been cleared. The second argument is the host device name. The third argument i… | ||
| 1.3.6.1.4.1.318.437 | NodexATSGeneratorVeryLowBatteryVoltDuringCrankAlarm | SEVERE: The generator's battery voltage has been detected as very low while cranking the engine. The first argument is the host device serial number. The secon… | ||
| 1.3.6.1.4.1.318.438 | NodexATSGeneratorVeryLowBatteryVoltDuringCrankAlarmCleared | INFORMATIONAL: The generator's high battery voltage while cranking condition has been cleared. The first argument is the host device serial number. The second … | ||
| 1.3.6.1.4.1.318.439 | NodexATSGeneratorEStop | SEVERE: The generator's emergency stop input has been activated. After the emergency stop signal has been removed, the E-Stop condition must be cleared before … | ||
| 1.3.6.1.4.1.318.440 | NodexATSGeneratorEStopCleared | INFORMATIONAL: The generator's emergency stop condition has been cleared. The first argument is the host device serial number. The second argument is the host … | ||
| 1.3.6.1.4.1.318.441 | NodexATSGeneratorHighBatteryVolt | WARNING: The generator's battery voltage has been detected as high. The first argument is the host device serial number. The second argument is the host device… | ||
| 1.3.6.1.4.1.318.442 | NodexATSGeneratorHighBatteryVoltCleared | INFORMATIONAL: The detected high battery voltage has been cleared, on the generator. The first argument is the host device serial number. The second argument i… | ||
| 1.3.6.1.4.1.318.443 | NodexATSGeneratorLowBatteryVolt | SEVERE: The generator's battery voltage has been detected as low. The first argument is the host device serial number. The second argument is the host device n… | ||
| 1.3.6.1.4.1.318.444 | NodexATSGeneratorLowBatteryVoltCleared | INFORMATIONAL: The detected low battery voltage has been cleared, on the generator. The first argument is the host device serial number. The second argument is… | ||
| 1.3.6.1.4.1.318.445 | NodexATSGeneratorControlSwitchNotAuto | SEVERE: The control switch on the generator is not in auto position. The first argument is the host device serial number. The second argument is the host devic… | ||
| 1.3.6.1.4.1.318.446 | NodexATSGeneratorControlSwitchNotAutoCleared | INFORMATIONAL: The control switch on the generator is in auto position. The first argument is the host device serial number. The second argument is the host de… | ||
| 1.3.6.1.4.1.318.447 | NodexATSGeneratorLowOilPressure | SEVERE: The generator's oil pressure has been detected as low. The first argument is the host device serial number. The second argument is the host device name… | ||
| 1.3.6.1.4.1.318.448 | NodexATSGeneratorLowOilPressureCleared | INFORMATIONAL: The detected low oil pressure has been cleared, on the generator. The first argument is the host device serial number. The second argument is th… | ||
| 1.3.6.1.4.1.318.449 | NodexATSGeneratorVeryLowOilPressure | SEVERE: The generator's oil pressure has been detected as very low. The first argument is the host device serial number. The second argument is the host device… | ||
| 1.3.6.1.4.1.318.450 | NodexATSGeneratorVeryLowOilPressureCleared | INFORMATIONAL: The detected v.low oil pressure has been cleared, on the generator. The first argument is the host device serial number. The second argument is … | ||
| 1.3.6.1.4.1.318.451 | NodexATSGeneratorOverload | SEVERE: The generator is overloaded. The first argument is the host device serial number. The second argument is the host device name. The third argument is th… | ||
| 1.3.6.1.4.1.318.452 | NodexATSGeneratorOverloadCleared | INFORMATIONAL: The generator is running within loading limits. The first argument is the host device serial number. The second argument is the host device name… | ||
| 1.3.6.1.4.1.318.453 | NodexATSGeneratorLowACVEvent | SEVERE: The generator AC voltage is outside the acceptable bounds. The first argument is the host device serial number. The second argument is the host device … | ||
| 1.3.6.1.4.1.318.454 | NodexATSGeneratorLowACVEventCleared | INFORMATIONAL: The generator AC voltage is within normal bounds. The first argument is the host device serial number. The second argument is the host device na… | ||
| 1.3.6.1.4.1.318.455 | NodexATSGeneratorHighACVEvent | SEVERE: The generator AC voltage is outside the acceptable bounds. The first argument is the host device serial number. The second argument is the host device … | ||
| 1.3.6.1.4.1.318.456 | NodexATSGeneratorHighACVEventCleared | INFORMATIONAL: The generator AC voltage is within normal bounds. The first argument is the host device serial number. The second argument is the host device na… | ||
| 1.3.6.1.4.1.318.457 | NodexATSGeneratorOverspeed | SEVERE: The generator is running over the acceptable RPM. The first argument is the host device serial number. The second argument is the host device name. The… | ||
| 1.3.6.1.4.1.318.458 | NodexATSGeneratorOverspeedCleared | INFORMATIONAL: The generator overspeed shutdown has been cleared. The first argument is the host device serial number. The second argument is the host device n… | ||
| 1.3.6.1.4.1.318.459 | NodexATSGeneratorEngineCold | SEVERE: The generator engine is cold, may not start. The first argument is the host device serial number. The second argument is the host device name. The thir… | ||
| 1.3.6.1.4.1.318.460 | NodexATSGeneratorEngineColdCleared | INFORMATIONAL: The engine is not cold to start. The first argument is the host device serial number. The second argument is the host device name. The third arg… | ||
| 1.3.6.1.4.1.318.461 | NodexATSGeneratorOutputBreakerOpen | SEVERE: The generators output breaker has been detected as open. The first argument is the host device serial number. The second argument is the host device na… | ||
| 1.3.6.1.4.1.318.462 | NodexATSGeneratorOutputBreakerOpenCleared | INFORMATIONAL: The engine is not cold to start. The first argument is the host device serial number. The second argument is the host device name. The third arg… | ||
| 1.3.6.1.4.1.318.463 | NodexATSGeneratorLowFuelLevelAlarm | WARNING: The tank fuel level is below the limits specified in the xATSGeneratorFuelSystemLowFuelLevelThreshold OID. The first argument is the host device seria… | ||
| 1.3.6.1.4.1.318.464 | NodexATSGeneratorLowFuelLevelAlarmCleared | INFORMATIONAL: The tank fuel level is back above the specified limit. The first argument is the host device serial number. The second argument is the host devi… | ||
| 1.3.6.1.4.1.318.465 | NodexATSGeneratorVeryLowFuelLevelAlarm | SEVERE: The tank fuel level is below the low threshold limits. The first argument is the host device serial number. The second argument is the host device name… | ||
| 1.3.6.1.4.1.318.466 | NodexATSGeneratorVeryLowFuelLevelAlarmCleared | INFORMATIONAL: The detected low tank level has been cleared in the device. The first argument is the host device serial number. The second argument is the host… | ||
| 1.3.6.1.4.1.318.467 | NodexATSGeneratorLowRunTimeAlarm | WARNING: The estimated runtime is below the limits specified. The first argument is the host device serial number. The second argument is the host device name.… | ||
| 1.3.6.1.4.1.318.468 | NodexATSGeneratorLowRunTimeAlarmCleared | INFORMATIONAL: The detected low runtime has been cleared in the device. The first argument is the host device serial number. The second argument is the host de… | ||
| 1.3.6.1.4.1.318.469 | NodexATSGeneratorVeryLowRunTimeAlarm | SEVERE: The estimated runtime is below the limits specified in the xATSGeneratorFuelSystemVeryLowRunTimeThreshold OID. The first argument is the host device se… | ||
| 1.3.6.1.4.1.318.470 | NodexATSGeneratorVeryLowRunTimeAlarmCleared | INFORMATIONAL: The detected low runtime has been cleared in the device. The first argument is the host device serial number. The second argument is the host de… | ||
| 1.3.6.1.4.1.318.471 | NodexATSGeneratorServiceDueAlarm | WARNING: The generator is due for scheduled service. Generation of this alarm is based on calendar days since and/or actual generator run-hours since last serv… | ||
| 1.3.6.1.4.1.318.472 | NodexATSGeneratorServiceDueAlarmCleared | INFORMATIONAL: The generator's service registers have been reset. The first argument is the host device serial number. The second argument is the host device n… | ||
| 1.3.6.1.4.1.318.473 | NodexATSGeneratorShutdown | SEVERE: The generator is shutdown. The first argument is the host device serial number. The second argument is the host device name. The third argument is the … | ||
| 1.3.6.1.4.1.318.474 | NodexATSGeneratorShutdownCleared | INFORMATIONAL: The generator shutdown alarm is cleared. The first argument is the host device serial number. The second argument is the host device name. The t… | ||
| 1.3.6.1.4.1.318.475 | NodexATSGeneratorBatteryCharger | SEVERE: The generator battery charger is nonfunctional. The first argument is the host device serial number. The second argument is the host device name. The t… | ||
| 1.3.6.1.4.1.318.476 | NodexATSGeneratorBatteryChargerCleared | INFORMATIONAL: Fault in the generator battery charger is cleared. The first argument is the host device serial number. The second argument is the host device n… | ||
| 1.3.6.1.4.1.318.477 | NodexATSGeneratorGenericEvent | WARNING: Any generic generator event. The first argument is the host device serial number. The second argument is the host device name. The third argument is t… | ||
| 1.3.6.1.4.1.318.478 | NodexATSGeneratorGenericEventCleared | INFORMATIONAL: Generated generic generator event is cleared. The first argument is the host device serial number. The second argument is the host device name. … | ||
| 1.3.6.1.4.1.318.479 | NodexPDUInternalCommErrorCleared | INFORMATIONAL: Internal communication has been restored. The first argument is the host device serial number. The second argument is the host device name. | ||
| 1.3.6.1.4.1.318.480 | NodexPDUSystemStateAlarm | SEVERE: The PDU's breakers (Q1, Q2 & Q3) are in a configuration that might lead to system unavailability. it may signify a temporary condition, when the breake… | ||
| 1.3.6.1.4.1.318.481 | NodexPDUSystemStateAlarmCleared | INFORMATIONAL: The PDU's breakers (Q1, Q2 & Q3) are set in a configuration that is a non-alarm state. The first argument is the host device serial number. The … | ||
| 1.3.6.1.4.1.318.482 | NodexPDUEpoTestMode | WARNING: The device's Emergency Power Off (EPO) circuit has been switched back to the test position. The first argument is the host device serial number. The s… | ||
| 1.3.6.1.4.1.318.483 | NodexPDUEpoArmed | INFORMATIONAL: The device's Emergency Power Off (EPO) circuit has been switched back to the armed position. The first argument is the host device serial number… | ||
| 1.3.6.1.4.1.318.484 | NodexPDUFuseBlownAlarm | SEVERE: One or more fuses in this PDU have been detected as open. These fuses are in the feed to the UPS associated with this PDU. The first argument is the ho… | ||
| 1.3.6.1.4.1.318.485 | NodexPDUFuseBlownAlarmCleared | INFORMATIONAL: A previous check fuse alarm in this PDU has cleared. These fuses are in the feed to the UPS associated with this PDU. The first argument is the … | ||
| 1.3.6.1.4.1.318.486 | NodexPDUBreakerPositionAlarm | SEVERE: A PDU breaker is in a state that compromises system availability. The first argument is the host device serial number. The second argument is the host … | ||
| 1.3.6.1.4.1.318.487 | NodexPDUBreakerPositionAlarmCleared | INFORMATIONAL: A PDU breaker is no longer in a state that compromises system availability. The first argument is the host device serial number. The second argu… | ||
| 1.3.6.1.4.1.318.488 | NodexPDUBreakerChangeEvent | INFORMATIONAL: A system breaker or switch within the device has changed state. They are generated when any of the Q1, Q2 or Q3 breakers have changed states. Th… | ||
| 1.3.6.1.4.1.318.489 | NodexPDUDataCommMismatchError | SEVERE: A data incompatibility exists within the device. This is typically the result of mismatches between firmware revisions of the transfer switch controlle… | ||
| 1.3.6.1.4.1.318.490 | NodexPDUDataCommMismatchErrorCleared | INFORMATIONAL: The internal data incompatibility has been resolved. The first argument is the host device serial number. The second argument is the host device… | ||
| 1.3.6.1.4.1.318.491 | NodexPDUSystemInMaintenanceBypassMode | WARNING: The PDU state has changed to maintenance bypass mode. The first argument is the host device serial number. The second argument is the host device name. | ||
| 1.3.6.1.4.1.318.492 | NodexPDUSystemInUPSOperationalMode | INFORMATIONAL: The PDU state has changed to UPS operational mode. The first argument is the host device serial number. The second argument is the host device n… | ||
| 1.3.6.1.4.1.318.493 | NodexATSGeneratorFuelTankRuptureAlarm | WARNING: Detected a rupture in the inner wall of the generator fuel tank. The first argument is the host device serial number. The second argument is the host … | ||
| 1.3.6.1.4.1.318.494 | NodexATSGeneratorFuelTankRuptureAlarmCleared | INFORMATIONAL: The rupture in the inner wall of the generator is not detected. The first argument is the host device serial number. The second argument is the … | ||
| 1.3.6.1.4.1.318.495 | NodexATSGeneratorGroundFaultAlarm | SEVERE: Generator ground fault alarm. The first argument is the host device serial number. The second argument is the host device name. The third argument is t… | ||
| 1.3.6.1.4.1.318.496 | NodexATSGeneratorGroundFaultAlarmCleared | INFORMATIONAL: Generator ground fault alarm cleared. The first argument is the host device serial number. The second argument is the host device name. The thir… | ||
| 1.3.6.1.4.1.318.497 | NodexATSOutputLoadPoweredByGeneratorAlarm | WARNING: The system load on the output of the ATS is being powered by source 2 (generator). The first argument is the host device serial number. The second arg… | ||
| 1.3.6.1.4.1.318.498 | NodexATSOutputLoadPoweredByGeneratorAlarmCleared | INFORMATIONAL: The system load on the output of the ATS is no longer being powered by source 2 (generator). The first argument is the host device serial number… | ||
| 1.3.6.1.4.1.318.499 | NodexAPCControllerFirmwareUpdateTransferStart | INFORMATIONAL: Start controller firmware transfer in the device. The first argument is the host device serial number. The second argument is the host model nam… | ||
| 1.3.6.1.4.1.318.500 | NodexAPCControllerFirmwareUpdateTransferComplete | INFORMATIONAL: Transfer of controller firmware was completed in the device. The first argument is the host device serial number. The second argument is the hos… | ||
| 1.3.6.1.4.1.318.501 | NodexAPCControllerFirmwareUpdateTransferFailed | SEVERE: Transfer of controller firmware failed. The first argument is the host device serial number. The second argument is the host device model name that fai… | ||
| 1.3.6.1.4.1.318.502 | NodeupsPfcInputRelayFailure | WARNING: The PFC (Power Factor Correction) input relay failure exists. | ||
| 1.3.6.1.4.1.318.503 | NodeupsPfcInputRelayFailureCleared | INFORMATIONAL: The PFC (Power Factor Correction) input relay failure cleared. | ||
| 1.3.6.1.4.1.318.504 | NodeupsInverterOverTemperature | WARNING: The inverter over temperature condition exists. | ||
| 1.3.6.1.4.1.318.505 | NodeupsInverterOverTemperatureCleared | INFORMATIONAL: The inverter over temperature condition cleared. | ||
| 1.3.6.1.4.1.318.506 | NodeupsBatteryOverVoltage | WARNING: The battery over voltage condition exists. | ||
| 1.3.6.1.4.1.318.507 | NodeupsBatteryOverVoltageCleared | INFORMATIONAL: The battery over voltage condition cleared. | ||
| 1.3.6.1.4.1.318.508 | NodeupsEepromFault | WARNING: The EEPROM fault exists. | ||
| 1.3.6.1.4.1.318.509 | NodeupsEepromFaultCleared | INFORMATIONAL: The EEPROM fault cleared. | ||
| 1.3.6.1.4.1.318.510 | NodearuFanRuntimeAlarm | WARNING: The total running hours for a fan has exceeded the run hour threshold. The first argument is the host device serial number. The second argument is the… | ||
| 1.3.6.1.4.1.318.511 | NodearuFanRuntimeAlarmCleared | INFORMATIONAL: The total running hours for a fan is no longer above the fan runhour threshold. The first argument is the host device serial number. The second … | ||
| 1.3.6.1.4.1.318.512 | NodearuFanPoorPerformanceAlarm | WARNING: Poor fan performance has been detected in the ARU, indicating that the fan may be close to failing. The first argument is the host device serial numbe… | ||
| 1.3.6.1.4.1.318.513 | NodearuFanPoorPerformanceAlarmCleared | INFORMATIONAL: Fan performance is no longer degraded. The first argument is the host device serial number. The second argument is the host device name. The thi… | ||
| 1.3.6.1.4.1.318.514 | NodearuRedundantPowerLostAlarm | WARNING: One of the redundant line cords on the ARU is no longer receiving AC power. The first argument is the host device serial number. The second argument i… | ||
| 1.3.6.1.4.1.318.515 | NodearuRedundantPowerLostAlarmCleared | INFORMATIONAL: Line-cord redundancy has been restored to the ARU. The first argument is the host device serial number. The second argument is the host device n… | ||
| 1.3.6.1.4.1.318.516 | NodeapcDeviceConfigChange | INFORMATIONAL: A device configuration change has been made on the device. The first argument is the device serial number. The second argument is the device nam… | ||
| 1.3.6.1.4.1.318.517 | NodeapcEnvSensorConnected | INFORMATIONAL: A sensor has been connected to the host device. The first argument is the host device serial number. The second argument is the host device name… | ||
| 1.3.6.1.4.1.318.518 | NodeapcEnvSensorDisconnected | SEVERE: A sensor has been disconnected from the device. The first argument is the host device serial number. The second argument is the host device name. The t… | ||
| 1.3.6.1.4.1.318.519 | NodeapcEnvMaxTempThresholdViolation | SEVERE: Max temperature threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The… | ||
| 1.3.6.1.4.1.318.520 | NodeapcEnvMaxTempThresholdViolationCleared | INFORMATIONAL: Max temperature threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host … | ||
| 1.3.6.1.4.1.318.521 | NodeapcEnvHighTempThresholdViolation | WARNING: High temperature threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. T… | ||
| 1.3.6.1.4.1.318.522 | NodeapcEnvHighTempThresholdViolationCleared | INFORMATIONAL: High temperature threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host… | ||
| 1.3.6.1.4.1.318.523 | NodeapcEnvLowTempThresholdViolation | WARNING: Low temperature threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. Th… | ||
| 1.3.6.1.4.1.318.524 | NodeapcEnvLowTempThresholdViolationCleared | INFORMATIONAL: Low temperature threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host … | ||
| 1.3.6.1.4.1.318.525 | NodeapcEnvMinTempThresholdViolation | SEVERE: Min temperature threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The… | ||
| 1.3.6.1.4.1.318.526 | NodeapcEnvMinTempThresholdViolationCleared | INFORMATIONAL: Min temperature threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host … | ||
| 1.3.6.1.4.1.318.527 | NodeapcEnvSTIncTempRateViolation | SEVERE: Short-term increasing temperature rate violated on the sensor. The first argument is the host device serial number. The second argument is the host dev… | ||
| 1.3.6.1.4.1.318.528 | NodeapcEnvSTIncTempRateViolationCleared | INFORMATIONAL: Short-term increasing temperature rate cleared on the sensor. The first argument is the host device serial number. The second argument is the ho… | ||
| 1.3.6.1.4.1.318.529 | NodeapcEnvSTDecTempRateViolation | SEVERE: Short-term decreasing temperature rate violated on the sensor. The first argument is the host device serial number. The second argument is the host dev… | ||
| 1.3.6.1.4.1.318.530 | NodeapcEnvSTDecTempRateViolationCleared | INFORMATIONAL: Short-term decreasing temperature rate cleared on the sensor. The first argument is the host device serial number. The second argument is the ho… | ||
| 1.3.6.1.4.1.318.531 | NodeapcEnvLTIncTempRateViolation | SEVERE: Long-term increasing temperature rate violated on the sensor. The first argument is the host device serial number. The second argument is the host devi… | ||
| 1.3.6.1.4.1.318.532 | NodeapcEnvLTIncTempRateViolationCleared | INFORMATIONAL: Long-term increasing temperature rate cleared on the sensor. The first argument is the host device serial number. The second argument is the hos… | ||
| 1.3.6.1.4.1.318.533 | NodeapcEnvLTDecTempRateViolation | SEVERE: Long-term decreasing temperature rate violated on the sensor. The first argument is the host device serial number. The second argument is the host devi… | ||
| 1.3.6.1.4.1.318.534 | NodeapcEnvLTDecTempRateViolationCleared | INFORMATIONAL: Long-term decreasing temperature rate cleared on the sensor. The first argument is the host device serial number. The second argument is the hos… | ||
| 1.3.6.1.4.1.318.535 | NodeapcEnvMaxHumidityThresholdViolation | SEVERE: Max humidity threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The th… | ||
| 1.3.6.1.4.1.318.536 | NodeapcEnvMaxHumidityThresholdViolationCleared | INFORMATIONAL: Max humidity threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host dev… | ||
| 1.3.6.1.4.1.318.537 | NodeapcEnvHighHumidityThresholdViolation | WARNING: High humidity threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The … | ||
| 1.3.6.1.4.1.318.538 | NodeapcEnvHighHumidityThresholdViolationCleared | INFORMATIONAL: High humidity threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host de… | ||
| 1.3.6.1.4.1.318.539 | NodeapcEnvLowHumidityThresholdViolation | WARNING: Low humidity threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The t… | ||
| 1.3.6.1.4.1.318.540 | NodeapcEnvLowHumidityThresholdViolationCleared | INFORMATIONAL: Low humidity threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host dev… | ||
| 1.3.6.1.4.1.318.541 | NodeapcEnvMinHumidityThresholdViolation | SEVERE: Min humidity threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The th… | ||
| 1.3.6.1.4.1.318.542 | NodeapcEnvMinHumidityThresholdViolationCleared | INFORMATIONAL: Min humidity threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host dev… | ||
| 1.3.6.1.4.1.318.543 | NodeapcBeaconConnected | INFORMATIONAL: A beacon has been connected to the device. The first argument is the host device serial number. The second argument is the host device name. The… | ||
| 1.3.6.1.4.1.318.544 | NodeapcBeaconDisconnected | SEVERE: A beacon has been disconnected from the device. The first argument is the host device serial number. The second argument is the host device name. The t… | ||
| 1.3.6.1.4.1.318.545 | NodeapcBeaconOn | INFORMATIONAL: A beacon has gone on (activated). The first argument is the host device serial number. The second argument is the host device name. The third ar… | ||
| 1.3.6.1.4.1.318.546 | NodeapcBeaconOff | INFORMATIONAL: A beacon has gone off (deactivated). The first argument is the host device serial number. The second argument is the host device name. The third… | ||
| 1.3.6.1.4.1.318.547 | NodeapcOutletStateAbnormal | WARNING: An outlet on the device has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device… | ||
| 1.3.6.1.4.1.318.548 | NodeapcOutletStateNormal | INFORMATIONAL: An outlet on the device has changed to its normal state. The first argument is the host device serial number. The second argument is the host de… | ||
| 1.3.6.1.4.1.318.549 | NodeapcOutputRelayStateAbnormal | WARNING: An output relay on the device has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host … | ||
| 1.3.6.1.4.1.318.550 | NodeapcOutputRelayStateNormal | INFORMATIONAL: An output relay on the device has changed to its normal state. The first argument is the host device serial number. The second argument is the h… | ||
| 1.3.6.1.4.1.318.551 | NodeapcHardwareStateAbnormal | SEVERE: The device's hardware is improperly configured and operating outside normal bounds for the hardware. This can be caused by improper devices being conne… | ||
| 1.3.6.1.4.1.318.552 | NodeapcHardwareStateNormal | INFORMATIONAL: The device's hardware is in its normal operational state. The first argument is the host device serial number. The second argument is the host d… | ||
| 1.3.6.1.4.1.318.553 | NodeapcCriticalDiscreteInputContactStateAbnormal | SEVERE: A discrete input contact on the device has changed to its abnormal state. The first argument is the host device serial number. The second argument is t… | ||
| 1.3.6.1.4.1.318.554 | NodeapcCriticalDiscreteInputContactStateNormal | INFORMATIONAL: A discrete input contact on the device has changed to its normal state. The first argument is the host device serial number. The second argument… | ||
| 1.3.6.1.4.1.318.555 | NodeapcWarningDiscreteInputContactStateAbnormal | WARNING: A discrete input contact on the device has changed to its abnormal state. The first argument is the host device serial number. The second argument is … | ||
| 1.3.6.1.4.1.318.556 | NodeapcWarningDiscreteInputContactStateNormal | INFORMATIONAL: A discrete input contact on the device has changed to its normal state. The first argument is the host device serial number. The second argument… | ||
| 1.3.6.1.4.1.318.557 | NodeapcInformationalDiscreteInputContactStateAbnormal | INFORMATIONAL: A discrete input contact on the device has changed to its abnormal state. The first argument is the host device serial number. The second argume… | ||
| 1.3.6.1.4.1.318.558 | NodeapcInformationalDiscreteInputContactStateNormal | INFORMATIONAL: A discrete input contact on the device has changed to its normal state. The first argument is the host device serial number. The second argument… | ||
| 1.3.6.1.4.1.318.559 | NodeapcAnalogInputMaxThresholdViolation | SEVERE: Maximum threshold violated on an analog input. The first argument is the host device serial number. The second argument is the host device name. The th… | ||
| 1.3.6.1.4.1.318.560 | NodeapcAnalogInputMaxThresholdViolationCleared | INFORMATIONAL: Maximum threshold violation cleared on the analog input. The first argument is the host device serial number. The second argument is the host de… | ||
| 1.3.6.1.4.1.318.561 | NodeapcAnalogInputHighThresholdViolation | WARNING: High threshold violated on an analog input. The first argument is the host device serial number. The second argument is the host device name. The thir… | ||
| 1.3.6.1.4.1.318.562 | NodeapcAnalogInputHighThresholdViolationCleared | INFORMATIONAL: High threshold violation cleared on the analog input. The first argument is the host device serial number. The second argument is the host devic… | ||
| 1.3.6.1.4.1.318.563 | NodeapcAnalogInputLowThresholdViolation | WARNING: Low threshold violated on an analog input. The first argument is the host device serial number. The second argument is the host device name. The third… | ||
| 1.3.6.1.4.1.318.564 | NodeapcAnalogInputLowThresholdViolationCleared | INFORMATIONAL: Low threshold violation cleared on the analog input. The first argument is the host device serial number. The second argument is the host device… | ||
| 1.3.6.1.4.1.318.565 | NodeapcAnalogInputMinThresholdViolation | SEVERE: Minimum threshold violated on an analog input. The first argument is the host device serial number. The second argument is the host device name. The th… | ||
| 1.3.6.1.4.1.318.566 | NodeapcAnalogInputMinThresholdViolationCleared | INFORMATIONAL: Minimum threshold violation cleared on the analog input. The first argument is the host device serial number. The second argument is the host de… | ||
| 1.3.6.1.4.1.318.567 | NodeapcDeviceClearLostComms | INFORMATIONAL: Lost communications reset command has been issued. The first argument is the device serial number. The second argument is the device name. The t… | ||
| 1.3.6.1.4.1.318.568 | NodeapcDeviceConnected | INFORMATIONAL: A device has been connected to the host. The first argument is the host serial number. The second argument is the host name. The third argument … | ||
| 1.3.6.1.4.1.318.569 | NodeapcDeviceDisconnected | SEVERE: A device has been disconnected from the host. The first argument is the host serial number. The second argument is the host name. The third argument is… | ||
| 1.3.6.1.4.1.318.570 | NodeapcUnregisteredUserAccessDenied | INFORMATIONAL: An unregistered user has tried to access the device. The first argument is the host device serial number. The second argument is the host device… | ||
| 1.3.6.1.4.1.318.571 | NodeapcRegisteredUserAccessDenied | INFORMATIONAL: A registered user has been denied access to the device. The first argument is the host device serial number. The second argument is the host dev… | ||
| 1.3.6.1.4.1.318.572 | NodeapcRegisteredUserConfigChange | INFORMATIONAL: Registered user configuration change. The first argument is the host device serial number. The second argument is the host device name. The thir… | ||
| 1.3.6.1.4.1.318.573 | NodeapcDoorUnlocked | INFORMATIONAL: A door has been unlocked. The first argument is the host device serial number. The second argument is the host device name. The third argument i… | ||
| 1.3.6.1.4.1.318.574 | NodeapcDoorLocked | INFORMATIONAL: A door has been locked. The first argument is the host device serial number. The second argument is the host device name. The third argument is … | ||
| 1.3.6.1.4.1.318.575 | NodeapcHandleOpened | INFORMATIONAL: A door handle has been opened. The first argument is the host device serial number. The second argument is the host device name. The third argum… | ||
| 1.3.6.1.4.1.318.576 | NodeapcHandleClosed | INFORMATIONAL: A door handle has been closed. The first argument is the host device serial number. The second argument is the host device name. The third argum… | ||
| 1.3.6.1.4.1.318.577 | NodeapcDoorOpened | INFORMATIONAL: A door has been opened. The first argument is the host device serial number. The second argument is the host device name. The third argument is … | ||
| 1.3.6.1.4.1.318.578 | NodeapcDoorClosed | INFORMATIONAL: A door has been closed. The first argument is the host device serial number. The second argument is the host device name. The third argument is … | ||
| 1.3.6.1.4.1.318.580 | NodeapcKeyOverrideUnlocked | SEVERE: Key override unlock has occurred. The first argument is the host device serial number. The second argument is the host device name. The third argument … | ||
| 1.3.6.1.4.1.318.581 | NodeapcKeyOverrideLocked | INFORMATIONAL: Key override lock has occurred. The first argument is the host device serial number. The second argument is the host device name. The third argu… | ||
| 1.3.6.1.4.1.318.582 | NodeapcForcedEntry | SEVERE: A forced entry condition has occurred. The first argument is the host device serial number. The second argument is the host device name. The third argu… | ||
| 1.3.6.1.4.1.318.583 | NodeapcForcedEntryCleared | INFORMATIONAL: A forced entry condition has been cleared. The first argument is the host device serial number. The second argument is the host device name. The… | ||
| 1.3.6.1.4.1.318.584 | NodeapcRelockTimeout | SEVERE: A relock timout has occurred. The first argument is the host device serial number. The second argument is the host device name. The third argument is t… | ||
| 1.3.6.1.4.1.318.585 | NodeapcRelockTimeoutCleared | INFORMATIONAL: A relock timout has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third ar… | ||
| 1.3.6.1.4.1.318.586 | NodeapcDoorSenseDisconnected | SEVERE: A door sensor was disconnected. The first argument is the host device serial number. The second argument is the host device name. The third argument is… | ||
| 1.3.6.1.4.1.318.587 | NodeapcDoorSenseConnected | INFORMATIONAL: A forced entry condition has been cleared. The first argument is the host device serial number. The second argument is the host device name. The… | ||
| 1.3.6.1.4.1.318.588 | NodeapcDoorLostComms | SEVERE: Communications have been lost with the door. The first argument is the host device serial number. The second argument is the host device name. The thir… | ||
| 1.3.6.1.4.1.318.589 | NodeapcDoorEstablishedComms | INFORMATIONAL: Communications have been established with the door. The first argument is the host device serial number. The second argument is the host device … | ||
| 1.3.6.1.4.1.318.590 | NodeapcRegisteredUserAccessChange | INFORMATIONAL: Registered user access changed. The first argument is the host device serial number. The second argument is the host device name. The third argu… | ||
| 1.3.6.1.4.1.318.591 | NodeapcUnregisteredUserStatusChange | INFORMATIONAL: Unregistered user status changed. The first argument is the host device serial number. The second argument is the host device name. The third ar… | ||
| 1.3.6.1.4.1.318.592 | NodeapcDeviceClearUserConfigs | INFORMATIONAL: User configurations reset command has been issued. The first argument is the device serial number. The second argument is the device name. The t… | ||
| 1.3.6.1.4.1.318.600 | NodeupsBatteryTempSensorFault | WARNING: The battery temperature sensor fault exists. | ||
| 1.3.6.1.4.1.318.601 | NodeupsBatteryTempSensorFaultCleared | INFORMATIONAL: The battery temperature sensor fault cleared. | ||
| 1.3.6.1.4.1.318.602 | NodeupsBatterySoftBusStartFault | WARNING: A battery bus soft start fault exists. | ||
| 1.3.6.1.4.1.318.603 | NodeupsBatterySoftBusStartFaultCleared | INFORMATIONAL: A battery bus soft start fault exists cleared. | ||
| 1.3.6.1.4.1.318.604 | NodeapcOutputShortCircuit | WARNING: An output short circuit condition exists. | ||
| 1.3.6.1.4.1.318.605 | NodeapcOutputShortCircuitCleared | INFORMATIONAL: An output short circuit condition cleared. | ||
| 1.3.6.1.4.1.318.606 | NodeapcOutputRelayFault | WARNING: An output relay (or its driver) fault exists. | ||
| 1.3.6.1.4.1.318.607 | NodeapcOutputRelayFaultCleared | INFORMATIONAL: An output relay (or its driver) fault cleared. | ||
| 1.3.6.1.4.1.318.608 | NodeupsPfcFault | WARNING: A PFC fault exists. | ||
| 1.3.6.1.4.1.318.609 | NodeupsPfcFaultCleared | INFORMATIONAL: The PFC fault cleared. | ||
| 1.3.6.1.4.1.318.610 | NodeapcDcBusOverVoltage | WARNING: The DC bus voltage is too high. | ||
| 1.3.6.1.4.1.318.611 | NodeapcDcBusOverVoltageCleared | INFORMATIONAL: The DC bus voltage is too high cleared. | ||
| 1.3.6.1.4.1.318.612 | NodeupsInverterFault | WARNING: The inverter fault exists. | ||
| 1.3.6.1.4.1.318.613 | NodeupsInverterFaultCleared | INFORMATIONAL: The inverter fault cleared. | ||
| 1.3.6.1.4.1.318.614 | NodeapcAdConverterFault | WARNING: The A/D converter fault exists. | ||
| 1.3.6.1.4.1.318.615 | NodeapcAdConverterFaultCleared | INFORMATIONAL: The A/D converter fault cleared. | ||
| 1.3.6.1.4.1.318.616 | NodeapcLogicPowerSupplyFault | WARNING: A logic power supply fault exists. | ||
| 1.3.6.1.4.1.318.617 | NodeapcLogicPowerSupplyFaultCleared | INFORMATIONAL: A logic power supply fault cleared. | ||
| 1.3.6.1.4.1.318.618 | NodeapcTransformerDCImbalanceFault | WARNING: The DC component of the transformer's current is too high. | ||
| 1.3.6.1.4.1.318.619 | NodeapcTransformerDCImbalanceFaultCleared | WARNING: The DC component of the transformer's current is normal. | ||
| 1.3.6.1.4.1.318.620 | NodeupsBackfeedRelayFault | WARNING: The backfeed relay (or its driver) has a fault. | ||
| 1.3.6.1.4.1.318.621 | NodeupsBackfeedRelayFaultCleared | WARNING: The backfeed relay (or its driver) has a fault cleared. | ||
| 1.3.6.1.4.1.318.622 | NodeupsBypassRelayFault | WARNING: A bypass relay (or its driver) has a fault. | ||
| 1.3.6.1.4.1.318.623 | NodeupsBypassRelayFaultCleared | WARNING: A bypass relay (or its driver) has a fault cleared. | ||
| 1.3.6.1.4.1.318.626 | NodexPDUBranchCurrentMinAlarm | SEVERE: The current in a branch circuit is outside the limits specified for that branch circuit. The first argument is the host device serial number. The secon… | ||
| 1.3.6.1.4.1.318.627 | NodexPDUBranchCurrentMinAlarmCleared | INFORMATIONAL: The current in a branch circuit is back within the limits specified for that branch circuit. The first argument is the host device serial number… | ||
| 1.3.6.1.4.1.318.628 | NodexPDUBranchCurrentMaxAlarm | SEVERE: The current in a branch circuit is outside the limits specified for that branch circuit. The first argument is the host device serial number. The secon… | ||
| 1.3.6.1.4.1.318.629 | NodexPDUBranchCurrentMaxAlarmCleared | INFORMATIONAL: The current in a branch circuit is back within the limits specified for that branch circuit. The first argument is the host device serial number… | ||
| 1.3.6.1.4.1.318.630 | NoderPDUOutletLowLoad | WARNING: A Rack PDU has violated the outlet low load threshold. The first argument is the serial number. The second argument is the device name. The third argu… | ||
| 1.3.6.1.4.1.318.631 | NoderPDUOutletLowLoadCleared | INFORMATIONAL: The outlet low load condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. T… | ||
| 1.3.6.1.4.1.318.632 | NoderPDUOutletNearOverload | WARNING: A Rack PDU is near an outlet overload condition. The first argument is the serial number. The second argument is the device name. The third argument i… | ||
| 1.3.6.1.4.1.318.633 | NoderPDUOutletNearOverloadCleared | INFORMATIONAL: The outlet near overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device na… | ||
| 1.3.6.1.4.1.318.634 | NoderPDUOutletOverload | SEVERE: A Rack PDU is in an overload condition. The first argument is the serial number. The second argument is the device name. The third argument is the outl… | ||
| 1.3.6.1.4.1.318.635 | NoderPDUOutletOverloadCleared | INFORMATIONAL: The outlet overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. T… | ||
| 1.3.6.1.4.1.318.636 | NodeapcTestTrap | INFORMATIONAL: Trap used to test SNMP trap functionality. The first argument is a place holder for test variables. | ||
| 1.3.6.1.4.1.318.637 | NodebaseFanFailureCleared | INFORMATIONAL: Base module fan has been repaired | ||
| 1.3.6.1.4.1.318.638 | NodeatsLowLoad | WARNING: ATS has violated the bank or phase low load threshold. The first argument is the serial number. The second argument is the product name. The third arg… | ||
| 1.3.6.1.4.1.318.639 | NodeatsLowLoadCleared | INFORMATIONAL: The bank or phase low load condition on an ATS has been cleared. The first argument is the serial number. The second argument is the product nam… | ||
| 1.3.6.1.4.1.318.640 | NodeatsNearOverload | WARNING: ATS has violated the bank or phase near overload threshold. The first argument is the serial number. The second argument is the product name. The thir… | ||
| 1.3.6.1.4.1.318.641 | NodeatsNearOverloadCleared | INFORMATIONAL: The bank or phase near overload condition on an ATS has been cleared. The first argument is the serial number. The second argument is the produc… | ||
| 1.3.6.1.4.1.318.642 | NodeatsOverload | SEVERE: ATS is in an overload condition. The first argument is the serial number. The second argument is the product name. The third argument is the phase numb… | ||
| 1.3.6.1.4.1.318.643 | NodeatsOverloadCleared | INFORMATIONAL: The bank or phase overload condition on an ATS has been cleared. The first argument is the serial number. The second argument is the product nam… | ||
| 1.3.6.1.4.1.318.644 | NodeatsRMSOverVoltage | SEVERE: Overvoltage condition violated. The first argument is the serial number. The second argument is the product name. The third argument is an integer repr… | ||
| 1.3.6.1.4.1.318.645 | NodeatsRMSOverVoltageCleared | INFORMATIONAL: Overvoltage condition cleared. The first argument is the serial number. The second argument is the product name. The third argument is an intege… | ||
| 1.3.6.1.4.1.318.646 | NodeatsRMSUnderVoltage | SEVERE: Undervoltage condition violated. The first argument is the serial number. The second argument is the product name. The third argument is an integer rep… | ||
| 1.3.6.1.4.1.318.647 | NodeatsRMSUnderVoltageCleared | INFORMATIONAL: Undervoltage condition cleared. The first argument is the serial number. The second argument is the product name. The third argument is an integ… | ||
| 1.3.6.1.4.1.318.648 | NodeatsRMSOverFrequency | SEVERE: OverFrequency condition violated. The first argument is the serial number. The second argument is the product name. The third argument is an integer re… | ||
| 1.3.6.1.4.1.318.649 | NodeatsRMSOverFrequencyCleared | INFORMATIONAL: OverFrequency condition cleared. The first argument is the serial number. The second argument is the product name. The third argument is an inte… | ||
| 1.3.6.1.4.1.318.650 | NodeatsRMSUnderFrequency | SEVERE: UnderFrequency condition violated. The first argument is the serial number. The second argument is the product name. The third argument is an integer r… | ||
| 1.3.6.1.4.1.318.651 | NodeatsRMSUnderFrequencyCleared | INFORMATIONAL: UnderFrequency condition cleared. The first argument is the serial number. The second argument is the product name. The third argument is an int… | ||
| 1.3.6.1.4.1.318.652 | NodeisxModularDistributionCommLost | SEVERE: Communication with a metering segment of the modular distribution system has been lost. The first argument is the host device serial number. The second… | ||
| 1.3.6.1.4.1.318.653 | NodeisxModularDistributionCommEstablished | INFORMATIONAL: Communication with a metering segment of the modular distribution system has been restored. The first argument is the host device serial number.… | ||
| 1.3.6.1.4.1.318.654 | NodeisxModularDistributionModuleInserted | INFORMATIONAL: A distribution module has been inserted into the system. The first argument is the host device serial number. The second argument is the host de… | ||
| 1.3.6.1.4.1.318.655 | NodeisxModularDistributionModuleRemoved | INFORMATIONAL: A distribution module has been removed from the system. The first argument is the host device serial number. The second argument is the host dev… | ||
| 1.3.6.1.4.1.318.656 | NodeisxModularBreakerOpenAlarm | SEVERE: A distribution module breaker is open and in an alarm condition. The first argument is the host device serial number. The second argument is the host d… | ||
| 1.3.6.1.4.1.318.657 | NodeisxModularBreakerOpenAlarmCleared | INFORMATIONAL: An alarm caused by a distribution breaker being open has been cleared. The first argument is the host device serial number. The second argument … | ||
| 1.3.6.1.4.1.318.658 | NodeisxModularMinCurrentThresholdViolation | SEVERE: The current in a distribution module is below the minimum/critical limit specified for the circuit/cable. The first argument is the host device serial … | ||
| 1.3.6.1.4.1.318.659 | NodeisxModularMinCurrentThresholdViolationCleared | INFORMATIONAL: The current in a distribution module is no longer below the minimum/critical limit specified for the circuit/cable. The first argument is the ho… | ||
| 1.3.6.1.4.1.318.660 | NodeisxModularLowCurrentThresholdViolation | WARNING: The current in a distribution module is below the low/warning limit specified for the circuit/cable. The first argument is the host device serial numb… | ||
| 1.3.6.1.4.1.318.661 | NodeisxModularLowCurrentThresholdViolationCleared | INFORMATIONAL: The current in a distribution module is no longer below the low/warning limit specified for the circuit/cable. The first argument is the host de… | ||
| 1.3.6.1.4.1.318.662 | NodeisxModularHighCurrentThresholdViolation | WARNING: The current in a distribution module is above the high/warning limit specified for the circuit/cable. The first argument is the host device serial num… | ||
| 1.3.6.1.4.1.318.663 | NodeisxModularHighCurrentThresholdViolationCleared | INFORMATIONAL: The current in a distribution module is no longer above the high/warning limit specified for the circuit/cable. The first argument is the host d… | ||
| 1.3.6.1.4.1.318.664 | NodeisxModularMaxCurrentThresholdViolation | SEVERE: The current in a distribution module is above the maximum/critical limit specified for the circuit/cable. The first argument is the host device serial … | ||
| 1.3.6.1.4.1.318.665 | NodeisxModularMaxCurrentThresholdViolationCleared | INFORMATIONAL: The current in a distribution module is no longer above the maximum/critical limit specified for the circuit/cable. The first argument is the ho… | ||
| 1.3.6.1.4.1.318.666 | NodeisxModularSubfeedBreakerOpenAlarm | SEVERE: A distribution subfeed breaker is open and in an alarm condition. The first argument is the host device serial number. The second argument is the host … | ||
| 1.3.6.1.4.1.318.667 | NodeisxModularSubfeedBreakerOpenAlarmCleared | INFORMATIONAL: An alarm caused by a distribution subfeed breaker being open has been cleared. The first argument is the host device serial number. The second a… | ||
| 1.3.6.1.4.1.318.668 | NodeisxModularSubfeedMinCurrentThresholdViolation | SEVERE: The current in a distribution subfeed is below the minimum/critical limit specified. The first argument is the host device serial number. The second ar… | ||
| 1.3.6.1.4.1.318.669 | NodeisxModularSubfeedMinCurrentThresholdViolationCleared | INFORMATIONAL: The current in a distribution subfeed is no longer below the minimum/critical limit specified. The first argument is the host device serial numb… | ||
| 1.3.6.1.4.1.318.670 | NodeisxModularSubfeedLowCurrentThresholdViolation | WARNING: The current in a distribution subfeed is below the low/warning limit specified. The first argument is the host device serial number. The second argume… | ||
| 1.3.6.1.4.1.318.671 | NodeisxModularSubfeedLowCurrentThresholdViolationCleared | INFORMATIONAL: The current in a distribution subfeed is no longer below the low/warning limit specified. The first argument is the host device serial number. T… | ||
| 1.3.6.1.4.1.318.672 | NodeisxModularSubfeedHighCurrentThresholdViolation | WARNING: The current in a distribution subfeed is above the high/warning limit specified. The first argument is the host device serial number. The second argum… | ||
| 1.3.6.1.4.1.318.673 | NodeisxModularSubfeedHighCurrentThresholdViolationCleared | INFORMATIONAL: The current in a distribution subfeed is no longer above the high/warning limit specified. The first argument is the host device serial number. … | ||
| 1.3.6.1.4.1.318.674 | NodeisxModularSubfeedMaxCurrentThresholdViolation | SEVERE: The current in a distribution subfeed is above the maximum/critical limit specified. The first argument is the host device serial number. The second ar… | ||
| 1.3.6.1.4.1.318.675 | NodeisxModularSubfeedMaxCurrentThresholdViolationCleared | INFORMATIONAL: The current in a distribution subfeed is no longer above the maximum/critical limit specified. The first argument is the host device serial numb… | ||
| 1.3.6.1.4.1.318.676 | NodeisxModularTotalOutputCurrentMinThresholdViolation | SEVERE: The total output current of the distribution is below the minimum/critical limit specified. The first argument is the host device serial number. The se… | ||
| 1.3.6.1.4.1.318.677 | NodeisxModularTotalOutputCurrentMinThresholdViolationCleared | INFORMATIONAL: The total output current of the distribution is no longer below the minimum/critical limit specified. The first argument is the host device seri… | ||
| 1.3.6.1.4.1.318.678 | NodeisxModularTotalOutputCurrentLowThresholdViolation | WARNING: The total output current of the distribution is below the low/warning limit specified. The first argument is the host device serial number. The second… | ||
| 1.3.6.1.4.1.318.679 | NodeisxModularTotalOutputCurrentLowThresholdViolationCleared | INFORMATIONAL: The total output current of the distribution is no longer below the low/warning limit specified. The first argument is the host device serial nu… | ||
| 1.3.6.1.4.1.318.680 | NodeisxModularTotalOutputCurrentHighThresholdViolation | WARNING: The total output current of the distribution is above the high/warning limit specified. The first argument is the host device serial number. The secon… | ||
| 1.3.6.1.4.1.318.681 | NodeisxModularTotalOutputCurrentHighThresholdViolationCleared | INFORMATIONAL: The total output current of the distribution is no longer above the high/warning limit specified. The first argument is the host device serial n… | ||
| 1.3.6.1.4.1.318.682 | NodeisxModularTotalOutputCurrentMaxThresholdViolation | SEVERE: The total output current of the distribution is above the maximum/critical limit specified. The first argument is the host device serial number. The se… | ||
| 1.3.6.1.4.1.318.683 | NodeisxModularTotalOutputCurrentMaxThresholdViolationCleared | INFORMATIONAL: The total output current of the distribution is no longer above the maximum/critical limit specified. The first argument is the host device seri… | ||
| 1.3.6.1.4.1.318.684 | NodeisxModularOutputVoltageMinThresholdViolation | SEVERE: The distribution output voltage is below the minimum/critical limit specified. The first argument is the host device serial number. The second argument… | ||
| 1.3.6.1.4.1.318.685 | NodeisxModularOutputVoltageMinThresholdViolationCleared | INFORMATIONAL: The distribution output voltage is no longer below the minimum/critical limit specified. The first argument is the host device serial number. Th… | ||
| 1.3.6.1.4.1.318.686 | NodeisxModularOutputVoltageLowThresholdViolation | WARNING: The distribution output voltage is below the low/warning limit specified. The first argument is the host device serial number. The second argument is … | ||
| 1.3.6.1.4.1.318.687 | NodeisxModularOutputVoltageLowThresholdViolationCleared | INFORMATIONAL: The distribution output voltage is no longer below the low/warning limit specified. The first argument is the host device serial number. The sec… | ||
| 1.3.6.1.4.1.318.688 | NodeisxModularOutputVoltageHighThresholdViolation | WARNING: The distribution output voltage is above the high/warning limit specified. The first argument is the host device serial number. The second argument is… | ||
| 1.3.6.1.4.1.318.689 | NodeisxModularOutputVoltageHighThresholdViolationCleared | INFORMATIONAL: The distribution output voltage is no longer above the high/warning limit specified. The first argument is the host device serial number. The se… | ||
| 1.3.6.1.4.1.318.690 | NodeisxModularOutputVoltageMaxThresholdViolation | SEVERE: The distribution output voltage is above the maximum/critical limit specified. The first argument is the host device serial number. The second argument… | ||
| 1.3.6.1.4.1.318.691 | NodeisxModularOutputVoltageMaxThresholdViolationCleared | INFORMATIONAL: The distribution output voltage is no longer above the maximum/critical limit specified. The first argument is the host device serial number. Th… | ||
| 1.3.6.1.4.1.318.692 | NodeapcDoorClosedImproperly | SEVERE: A door has been closed improperly. The first argument is the host device serial number. The second argument is the host device name. The third argument… | ||
| 1.3.6.1.4.1.318.693 | NodeapcDoorClosedImproperlyCleared | INFORMATIONAL: A door is no longer closed improperly. The first argument is the host device serial number. The second argument is the host device name. The thi… | ||
| 1.3.6.1.4.1.318.694 | NodeapcUserScheduleViolation | SEVERE: A user has had a door opened past the scheduled access period. The first argument is the host device serial number. The second argument is the host dev… | ||
| 1.3.6.1.4.1.318.695 | NodeapcUserScheduleViolationCleared | INFORMATIONAL: User schedule violation has been cleared. The first argument is the host device serial number. The second argument is the host device name. The … | ||
| 1.3.6.1.4.1.318.696 | NodeisxModularOutputFrequencyThresholdViolation | SEVERE: The distribution output frequency is outside of the operating range specified. The first argument is the host device serial number. The second argument… | ||
| 1.3.6.1.4.1.318.697 | NodeisxModularOutputFrequencyViolationCleared | INFORMATIONAL: The distribution output frequency is no longer out of range. The first argument is the host device serial number. The second argument is the hos… | ||
| 1.3.6.1.4.1.318.698 | NodeatsSourceStatusFail | SEVERE: ATS Source failed. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the … | ||
| 1.3.6.1.4.1.318.699 | NodeatsSourceStatusOk | INFORMATIONAL: ATS Source OK. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing t… | ||
| 1.3.6.1.4.1.318.700 | NodeatsHardwareStatusFail | SEVERE: ATS display board hardware failed. The first argument is the serial number. The second argument is the product name. The third argument is an integer r… | ||
| 1.3.6.1.4.1.318.701 | NodeatsHardwareStatusOk | INFORMATIONAL: ATS display board hardware ok. The first argument is the serial number. The second argument is the product name. The third argument is an intege… | ||
| 1.3.6.1.4.1.318.702 | NodeatsControllerRestart | INFORMATIONAL: ATS Controller restarted. | ||
| 1.3.6.1.4.1.318.703 | NodeinputWarningError | WARNING: Input warning error has been detected. The first variable is the fault condition. | ||
| 1.3.6.1.4.1.318.704 | NodeinputOK | INFORMATIONAL: Input warning error has been cleared. The first variable is the fault condition. | ||
| 1.3.6.1.4.1.318.705 | NodebypassWarningError | WARNING: Bypass warning error has been detected. The first variable is the fault condition. | ||
| 1.3.6.1.4.1.318.706 | NodebypassOK | INFORMATIONAL: Bypass warning error has been cleared. The first variable is the fault condition. | ||
| 1.3.6.1.4.1.318.707 | NodecommunicationWarningError | WARNING: Communication warning error has been detected. The first variable is the fault condition. | ||
| 1.3.6.1.4.1.318.708 | NodecommunicationOK | INFORMATIONAL: Communication warning error has been cleared. The first variable is the fault condition. | ||
| 1.3.6.1.4.1.318.709 | NodepowerModuleSevereError | SEVERE: Power module severe error has been detected. The first variable is the fault condition. | ||
| 1.3.6.1.4.1.318.710 | NodepowerModuleOK | INFORMATIONAL: Power module severe error has been cleared. The first variable is the fault condition. | ||
| 1.3.6.1.4.1.318.711 | NodeoutputVoltageWaveformError | SEVERE: Output voltage waveform error has been detected. | ||
| 1.3.6.1.4.1.318.712 | NodeoutputVoltageWaveformOK | INFORMATIONAL: Output voltage waveform is OK. | ||
| 1.3.6.1.4.1.318.713 | NodebypassStaticSwitchOverload | SEVERE: Overload on bypass static switch has been detected. | ||
| 1.3.6.1.4.1.318.714 | NodenoOverloadOnBypassStaticSwitch | INFORMATIONAL: Overload on static bypass switch no longer present. | ||
| 1.3.6.1.4.1.318.715 | NodebatteryVoltageCollapse | SEVERE: Battery voltage collapse has been detected. | ||
| 1.3.6.1.4.1.318.716 | NodebatteryVoltageOK | INFORMATIONAL: Battery voltage OK. | ||
| 1.3.6.1.4.1.318.717 | NodeoverloadOnInstallation | SEVERE: Overload on installation has been detected. | ||
| 1.3.6.1.4.1.318.718 | NodenoOverloadOnInstallation | INFORMATIONAL: Overload on installation no longer present. | ||
| 1.3.6.1.4.1.318.719 | NodebypassStaticSwitchError | SEVERE: Bypass static switch error, module has critical error. | ||
| 1.3.6.1.4.1.318.720 | NodebypassStaticSwitchOK | INFORMATIONAL: Bypass static switch OK. | ||
| 1.3.6.1.4.1.318.721 | NodeforcedBypassSwitchActivated | SEVERE: Forced bypass switch has been activated. | ||
| 1.3.6.1.4.1.318.722 | NodeforcedBypassSwitchReleased | INFORMATIONAL: Forced bypass switch has been released. | ||
| 1.3.6.1.4.1.318.723 | NodeepoActivated | SEVERE: Emergency Power Off (EPO) switch has been activated. | ||
| 1.3.6.1.4.1.318.724 | NodexATSS1BadPhaseRotation | SEVERE: The device's source 1 phase rotation is bad. The first argument is the host device serial number. The second argument is the host device name. | ||
| 1.3.6.1.4.1.318.725 | NodexATSS1BadPhaseRotationCleared | INFORMATIONAL: The device's source 1 phase rotation is back to normal. The first argument is the host device serial number. The second argument is the host dev… | ||
| 1.3.6.1.4.1.318.726 | NodexATSS1BadPhaseBalance | SEVERE: The device's source 1 phase balance is out of bounds. The first argument is the host device serial number. The second argument is the host device name.… | ||
| 1.3.6.1.4.1.318.727 | NodexATSS1BadPhaseBalanceCleared | INFORMATIONAL: The device's source 1 phase balance is back to normal. The first argument is the host device serial number. The second argument is the host devi… | ||
| 1.3.6.1.4.1.318.728 | NodeisxModularTransformerOverheating | SEVERE: The distribution transformer temperature is too hot. The first argument is the host device serial number. The second argument is the host device name. | ||
| 1.3.6.1.4.1.318.729 | NodeisxModularTransformerOverheatingCleared | INFORMATIONAL: The distribution transformer temperature has returned to normal. The first argument is the host device serial number. The second argument is the… | ||
| 1.3.6.1.4.1.318.730 | NodeapcInternalCommunicationFault | SEVERE: An internal UPS communication fault exists. | ||
| 1.3.6.1.4.1.318.731 | NodeapcInternalCommunicationFaultCleared | INFORMATIONAL: An internal UPS communication fault no longer exists. | ||
| 1.3.6.1.4.1.318.732 | NodeupsOutletGroupCommand | WARNING: The specified Outlet Group command has been issued. | ||
| 1.3.6.1.4.1.318.733 | NodeonbatterycommunicationLost | SEVERE: Communication to the UPS when the UPS is on Battery. Steps to reestablish communication are in progress. | ||
| 1.3.6.1.4.1.318.734 | NodeupsCriticalCondition | SEVERE: A UPS critical condition was detected. The first variable is the error condition text message. The second variable is the error number. | ||
| 1.3.6.1.4.1.318.735 | NodeupsCriticalConditionCleared | INFORMATIONAL: A UPS critical condition has been cleared. The first variable is the fault condition. | ||
| 1.3.6.1.4.1.318.736 | NodeupsWarningCondition | WARNING: A UPS warning condition has been detected. The first variable is the fault condition. | ||
| 1.3.6.1.4.1.318.737 | NodeupsWarningConditionCleared | WARNING: A UPS warning condition has been cleared. The first variable is the fault condition. | ||
| 1.3.6.1.4.1.318.738 | NodeupsInformationalCondition | INFORMATIONAL: A UPS informational condition has been detected. The first variable is the fault condition. | ||
| 1.3.6.1.4.1.318.739 | NodeupsInformationalConditionCleared | INFORMATIONAL: A UPS informational condition has been cleared. The first variable is the fault condition. | ||
| 1.3.6.1.4.1.318.740 | NodeisxcInformationalAlarm | INFORMATIONAL: An ISXC Alarm exists. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third ar… | ||
| 1.3.6.1.4.1.318.741 | NodeisxcInformationalAlarmCleared | INFORMATIONAL: An ISXC Alarm has been cleared. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. Th… | ||
| 1.3.6.1.4.1.318.742 | NodeisxcWarningAlarm | WARNING: An ISXC Alarm exists. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument… | ||
| 1.3.6.1.4.1.318.743 | NodeisxcWarningAlarmCleared | WARNING: An ISXC Alarm has been cleared. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The thir… | ||
| 1.3.6.1.4.1.318.744 | NodeisxcErrorAlarm | ERROR: An ISXC Alarm exists. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument i… | ||
| 1.3.6.1.4.1.318.745 | NodeisxcErrorAlarmCleared | ERROR: An ISXC Alarm has been cleared. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third … | ||
| 1.3.6.1.4.1.318.746 | NodeisxcCriticalAlarm | CRITICAL: An ISXC Alarm exists. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argumen… | ||
| 1.3.6.1.4.1.318.747 | NodeisxcCriticalAlarmCleared | CRITICAL: An ISXC Alarm has been cleared. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The thi… | ||
| 1.3.6.1.4.1.318.748 | NodeisxcFailureAlarm | FAILURE: An ISXC Alarm exists. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument… | ||
| 1.3.6.1.4.1.318.749 | NodeisxcFailureAlarmCleared | FAILURE: An ISXC Alarm has been cleared. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The thir… | ||
| 1.3.6.1.4.1.318.750 | NoderpduCriticalCondition | SEVERE: A RPDU critical condition has been detected. The first variable is the serial number. The second variable is the device name. The third variable is the… | ||
| 1.3.6.1.4.1.318.751 | NoderpduCriticalConditionCleared | INFORMATIONAL: A RPDU critical condition has been cleared. The first variable is the serial number. The second variable is the device name. The third variable … | ||
| 1.3.6.1.4.1.318.752 | NoderpduWarningCondition | WARNING: A RPDU warning condition has been detected. The first variable is the serial number. The second variable is the device name. The third variable is the… | ||
| 1.3.6.1.4.1.318.753 | NoderpduWarningConditionCleared | WARNING: A RPDU warning condition has been cleared. The first variable is the serial number. The second variable is the device name. The third variable is the … | ||
| 1.3.6.1.4.1.318.754 | NoderpduInformationalCondition | INFORMATIONAL: A RPDU informational condition has been detected. The first variable is the serial number. The second variable is the device name. The third var… | ||
| 1.3.6.1.4.1.318.755 | NoderpduInformationalConditionCleared | INFORMATIONAL: A RPDU informational condition has been cleared. The first variable is the serial number. The second variable is the device name. The third vari… | ||
| 1.3.6.1.4.1.318.756 | NodeisxModularCoolingFanAlarm | SEVERE: The device's internal cooling fans have failed. The first argument is the host device serial number. The second argument is the host device name. | ||
| 1.3.6.1.4.1.318.757 | NodeisxModularCoolingFanAlarmCleared | INFORMATIONAL: The device's internal cooling fans are now functioning properly. The first argument is the host device serial number. The second argument is the… | ||
| 1.3.6.1.4.1.318.758 | NodeupsFirmwareUpdateStarted | WARNING: Updating UPS firmware. | ||
| 1.3.6.1.4.1.318.759 | NodeupsFirmwareUpdateFinished | INFORMATIONAL: Finished updating UPS firmware. | ||
| 1.3.6.1.4.1.318.760 | NodeupsFirmwareUpdateSucceeded | INFORMATIONAL: UPS firmware update succeeded. | ||
| 1.3.6.1.4.1.318.761 | NodeupsFirmwareUpdateFailed | WARNING: UPS firmware update failed. | ||
| 1.3.6.1.4.1.318.762 | NodeupsHasNoValidFirmware | SEVERE: UPS has no valid firmware. | ||
| 1.3.6.1.4.1.318.763 | NodeupsHasNoValidFirmwareCleared | INFORMATIONAL: UPS now has a valid firmware. | ||
| 1.3.6.1.4.1.318.767 | NodeupsLocalDisplayButtonFault | WARNING: A local display button fault exists. | ||
| 1.3.6.1.4.1.318.768 | NodeupsLocalDisplayButtonFaultCleared | INFORMATIONAL: A local display button fault no longer exists. | ||
| 1.3.6.1.4.1.318.769 | NodeupsNeedsFactorySetupFault | SEVERE: UPS needs factory setup. | ||
| 1.3.6.1.4.1.318.770 | NodeupsNeedsFactorySetupFaultCleared | INFORMATIONAL: UPS no longer needs factory setup. | ||
| 1.3.6.1.4.1.318.771 | NodeupsEPOActive | SEVERE: Emergency Power Off (EPO) active. | ||
| 1.3.6.1.4.1.318.772 | NodeupsEPOActiveCleared | INFORMATIONAL: Emergency Power Off (EPO) now inactive. | ||
| 1.3.6.1.4.1.318.773 | NodeupsFirmwareMismatch | SEVERE: A firmware mismatch error exists. | ||
| 1.3.6.1.4.1.318.774 | NodeupsFirmwareMismatchCleared | INFORMATIONAL: A firmware mismatch error no longer exists. | ||
| 1.3.6.1.4.1.318.775 | NodeupsOscillatorFailed | SEVERE: An oscillator error exists. | ||
| 1.3.6.1.4.1.318.776 | NodeupsOscillatorFailedCleared | INFORMATIONAL: An oscillator error no longer exists. | ||
| 1.3.6.1.4.1.318.777 | NodeupsOnBatteryDueToFault | SEVERE: The UPS is on battery due to an error. Symmetra UPSes: Intelligence module has reported being in self-test for too long. When this happens, the UPS is … | ||
| 1.3.6.1.4.1.318.778 | NodeupsOnBatteryDueToFaultCleared | INFORMATIONAL: The UPS is no longer on battery due to an error. | ||
| 1.3.6.1.4.1.318.779 | NodepcnsCriticalEventActive | SEVERE: PowerChute Network Shutdown has begun a safe shutdown of the host. | ||
| 1.3.6.1.4.1.318.780 | NodepcnsCriticalEventResolved | INFORMATIONAL: PowerChute Network Shutdown critical event resolved. Safe shutdown will continue. | ||
| 1.3.6.1.4.1.318.781 | NodepcnsNetworkComsLost | SEVERE: PowerChute cannot communicate with NMC | ||
| 1.3.6.1.4.1.318.782 | NodepcnsNetworkComsLostResolved | INFORMATIONAL: PowerChute can communicate with NMC again. | ||
| 1.3.6.1.4.1.318.783 | NodepcnsNMCComsLost | SEVERE: NMC cannot communicate with UPS. | ||
| 1.3.6.1.4.1.318.784 | NodepcnsNMCComsLostResolved | INFORMATIONAL: NMC can communicate with UPS again. | ||
| 1.3.6.1.4.1.318.785 | NodepcnsTest | INFORMATIONAL: PowerChute has sent a test trap. | ||
| 1.3.6.1.4.1.318.786 | NodepcnsUpdateAvailable | INFORMATIONAL: PowerChute has detected that a newer version is available. | ||
| 1.3.6.1.4.1.318.787 | NodetemporaryBypass | WARNING: UPS on temporary bypass | ||
| 1.3.6.1.4.1.318.790 | NodepcbeCriticalEventActive | SEVERE: PowerChute Business Edition has begun a safe shutdown of the host. | ||
| 1.3.6.1.4.1.318.791 | NodepcbeCriticalEventResolved | INFORMATIONAL: PowerChute Business Edition critical event resolved. Safe shutdown will continue. | ||
| 1.3.6.1.4.1.318.792 | NodepcbeComsLost | SEVERE: PowerChute cannot communicate with UPS | ||
| 1.3.6.1.4.1.318.793 | NodepcbeComsLostResolved | INFORMATIONAL: PowerChute can communicate with UPS again. | ||
| 1.3.6.1.4.1.318.794 | NodepcbeTest | INFORMATIONAL: PowerChute has sent a test trap. | ||
| 1.3.6.1.4.1.318.795 | NodepcbeUpdateAvailable | INFORMATIONAL: PowerChute has detected that a newer version is available. | ||
| 1.3.6.1.4.1.318.796 | NodepmmCriticalCondition | SEVERE: A PMM critical condition has been detected. The first variable is the serial number. The second variable is the device name. The third variable is the … | ||
| 1.3.6.1.4.1.318.797 | NodepmmCriticalConditionCleared | INFORMATIONAL: A PMM critical condition has been cleared. The first variable is the serial number. The second variable is the device name. The third variable i… | ||
| 1.3.6.1.4.1.318.798 | NodepmmWarningCondition | WARNING: A PMM warning condition has been detected. The first variable is the serial number. The second variable is the device name. The third variable is the … | ||
| 1.3.6.1.4.1.318.799 | NodepmmWarningConditionCleared | WARNING: A PMM warning condition has been cleared. The first variable is the serial number. The second variable is the device name. The third variable is the e… | ||
| 1.3.6.1.4.1.318.800 | NodepmmInformationalCondition | INFORMATIONAL: A PMM informational condition has been detected. The first variable is the serial number. The second variable is the device name. The third vari… | ||
| 1.3.6.1.4.1.318.801 | NodepmmInformationalConditionCleared | INFORMATIONAL: A PMM informational condition has been cleared. The first variable is the serial number. The second variable is the device name. The third varia… |