RB-MICRO-ATE-MIB
40 objects
Rainbow Micro-BST ATE
Imported Objects
| SNMPv2-SMI | enterprises Integer32 MODULE-IDENTITY OBJECT-TYPE |
| SNMPv2-TC | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.12394 | Nodealvarion | |||
| 1.3.6.1.4.1.12394.1 | Nodeproducts | |||
| 1.3.6.1.4.1.12394.1.2 | Noderainbow | |||
| 1.3.6.1.4.1.12394.1.2.302 | IdentityrainbowMicroBSTAteMib | Rainbow Micro-BST ATE | ||
| 1.3.6.1.4.1.12394.1.2.302.1 | NoderbAteMicroConfig | |||
| 1.3.6.1.4.1.12394.1.2.302.1.1 | ScalarrbAteMicroStartTest | read-write | current | To start ATE test perform SET with startFullTest (The NPU will reset and start Full test in ATE mode). When startHostTest the NPU will Start the only the host … |
| 1.3.6.1.4.1.12394.1.2.302.1.2 | ScalarrbAteMicroTimeToRunPhysicalTest | read-write | current | Time to run Physical test |
| 1.3.6.1.4.1.12394.1.2.302.1.3 | ScalarrbAteMicroNumOfPacketsToRunPhysTest | read-write | current | Number of Packets to run in Physical test |
| 1.3.6.1.4.1.12394.1.2.302.1.4 | ScalarrbAteMicroTestStatus | read-only | current | readyForTest - any test can be started. |
| 1.3.6.1.4.1.12394.1.2.302.1.5 | ScalarrbAteSnmpRelaySupport | read-write | current | rbAteSnmpRelaySupport - relay SNMP messages to AU/SU ON/OFF. Relaying is done according to community: @ATE@@AU.x = relay to AU in slot x. @ATE@@SU.xx-xx-xx-xx-… |
| 1.3.6.1.4.1.12394.1.2.302.2 | NoderbAteMicroClockConfig | |||
| 1.3.6.1.4.1.12394.1.2.302.2.1 | ScalarrbAteMicroDateDay | read-write | current | For reading or setting the date |
| 1.3.6.1.4.1.12394.1.2.302.2.2 | ScalarrbAteMicroDateDayOfWeek | read-write | current | For reading or setting the date |
| 1.3.6.1.4.1.12394.1.2.302.2.3 | ScalarrbAteMicroDateMonth | read-write | current | For reading or setting the date |
| 1.3.6.1.4.1.12394.1.2.302.2.4 | ScalarrbAteMicroDateYear | read-write | current | For reading or setting the date |
| 1.3.6.1.4.1.12394.1.2.302.2.5 | ScalarrbAteMicroDateHour | read-write | current | For reading or setting the time of day |
| 1.3.6.1.4.1.12394.1.2.302.2.6 | ScalarrbAteMicroDateMin | read-write | current | For reading or setting the time of day |
| 1.3.6.1.4.1.12394.1.2.302.2.7 | ScalarrbAteMicroDateSec | read-write | current | For reading or setting the time of day |
| 1.3.6.1.4.1.12394.1.2.302.3 | NoderbAteMicroTestResults | |||
| 1.3.6.1.4.1.12394.1.2.302.3.1 | NoderbAteMicroTestResultsConfig | |||
| 1.3.6.1.4.1.12394.1.2.302.3.1.1 | ScalarrbAteMicroSaveTestResultsToFlash | read-write | current | The NPU will save last test results to flash |
| 1.3.6.1.4.1.12394.1.2.302.3.1.2 | ScalarrbAteMicroRecallTestResultsFromFlash | read-write | current | The NPU will recall test results from flash into Memory |
| 1.3.6.1.4.1.12394.1.2.302.3.2 | NoderbAteMicroTestResultsTab | |||
| 1.3.6.1.4.1.12394.1.2.302.3.2.1 | TablerbAteMicroTestResultsTable | not-accessible | current | Table to get all Test Results |
| 1.3.6.1.4.1.12394.1.2.302.3.2.1.1 | RowrbAteMicroTestResultsEntry | not-accessible | current | Row Description |
| 1.3.6.1.4.1.12394.1.2.302.3.2.1.1.1 | ColumnrbAteMicroTestType | read-only | current | Type Of Test |
| 1.3.6.1.4.1.12394.1.2.302.3.2.1.1.2 | ColumnrbAteMicroTestResult | read-only | current | Last Test Result! |
| 1.3.6.1.4.1.12394.1.2.302.3.2.1.1.3 | ColumnrbAteMicroTestResultVal | read-only | current | Last Test Result Value! |
| 1.3.6.1.4.1.12394.1.2.302.3.2.1.1.4 | ColumnrbAteMicroTestResultDescription | read-only | current | Test Result Description! |
| 1.3.6.1.4.1.12394.1.2.302.4 | NoderbAteMicroBurnFuncs | |||
| 1.3.6.1.4.1.12394.1.2.302.4.1 | ScalarrbAteMicroEnterSerialNum | read-write | current | To start ATE burn functionality! locked after first burn! |
| 1.3.6.1.4.1.12394.1.2.302.4.2 | ScalarrbAteMicroEnterDataMacAddr | read-write | current | To start ATE burn functionality! locked after first burn! |
| 1.3.6.1.4.1.12394.1.2.302.4.3 | ScalarrbAteMicroEnterMngmntMacAddr | read-write | current | To start ATE burn functionality! locked after first burn! |
| 1.3.6.1.4.1.12394.1.2.302.4.4 | ScalarrbAteMicroGetIduHwRevision | read-only | current | To start ATE burn functionality! locked after first burn! |
| 1.3.6.1.4.1.12394.1.2.302.5 | NoderbAteMicroCleanUpParams | |||
| 1.3.6.1.4.1.12394.1.2.302.5.1 | ScalarrbAteMicroDeleteNpuShadowFile | read-write | current | Deletes the existing file name! |
| 1.3.6.1.4.1.12394.1.2.302.5.2 | ScalarrbAteMicroSetServiceDefault | read-write | current | Sets a Services to default and reboots NPU! |
| 1.3.6.1.4.1.12394.1.2.302.5.3 | ScalarrbAteMicroPowerOnCntReset | read-write | current | Resets the Cumulative Power On Time Counter |
| 1.3.6.1.4.1.12394.1.2.302.6 | NoderbAteManualTests | |||
| 1.3.6.1.4.1.12394.1.2.302.6.1 | ScalarrbAteLedTest | read-write | current | Activates/deactivates LED test! |