The management information definitions for the system resources management of a Redback network device. This MIB is viewable under all contexts.
OIDNameAccessStatusDescription
1.3.6.1.4.1.2352.2.24IdentityrbnSysResourcesMibThe management information definitions for the system resources management of a Redback network device. This MIB is viewable under all contexts.
1.3.6.1.4.1.2352.2.24.0NoderbnSRMIBNotifications
1.3.6.1.4.1.2352.2.24.0.1NotificationrbnSRProcessEventcurrentThis notification is sent each time the agent is informed of a process death/birth event.
1.3.6.1.4.1.2352.2.24.0.2NotificationrbnSRSwitchoverEventcurrentThis notification identifies when a switchover occurs from one main processor module to a backup.
1.3.6.1.4.1.2352.2.24.0.3NotificationrbnSRStorageFailedEventcurrentThis notification is sent when the value of rbnSRStorageStatus for a device changes to 'failed'.
1.3.6.1.4.1.2352.2.24.0.4NotificationrbnSRPowerExceededEventcurrentThis notification identifies when a controller card is inserted and results in more power being drawn than recommended.
1.3.6.1.4.1.2352.2.24.0.5NotificationrbnSseDiskHealthDegradedAlarmcurrentA rbnSseDiskHealthDegradedAlarm notification signifies that the hard disk health has degraded.
1.3.6.1.4.1.2352.2.24.0.6NotificationrbnSseDiskFailedAlarmcurrentA rbnSseDiskFailedAlarm notification signifies that the hard disk has failed.
1.3.6.1.4.1.2352.2.24.0.7NotificationrbnSseDiskMissingAlarmcurrentA rbnSseDiskMissingAlarm notification signifies that the hard disk is missing.
1.3.6.1.4.1.2352.2.24.0.8NotificationrbnSseDiskUnsupportedAlarmcurrentA rbnSseDiskUnsupportedAlarm notification signifies that the hard disk is not supported.
1.3.6.1.4.1.2352.2.24.0.9NotificationrbnSseDiskOOSAlarmcurrentA rbnSseDiskOOSAlarm notification signifies that the hard disk is out of service.
1.3.6.1.4.1.2352.2.24.0.10NotificationrbnSseDiskVoltageFailureAlarmcurrentA rbnSseDiskVoltageFailureAlarm notification signifies that the hard disk voltage has failed.
1.3.6.1.4.1.2352.2.24.0.11NotificationrbnSseDiskOverHeatAlarmcurrentA rbnSseDiskOverHeatAlarm notification signifies that the hard disk overheating.
1.3.6.1.4.1.2352.2.24.0.12NotificationrbnSseDiskReadFailureAlarmcurrentA rbnSseDiskReadFailureAlarm notification signifies that the hard disk read failure.
1.3.6.1.4.1.2352.2.24.0.13NotificationrbnIssuStateChangecurrentA notification reporting a change in ISSU state. The new state is returned in the notification.
1.3.6.1.4.1.2352.2.24.0.14NotificationrbnChassisAlarmcurrentA rbnChassisAlarm notification signifies that an alarm has been raised/cleared on the chassis.
1.3.6.1.4.1.2352.2.24.1NoderbnSRMIBObjects
1.3.6.1.4.1.2352.2.24.1.1NoderbnSRProcess
1.3.6.1.4.1.2352.2.24.1.1.1ScalarrbnSRProcessNotifyLastUpdateread-onlycurrentThe value of sysUpTime when an entry in the rbnSRProcessNotifyTable was last added. Because this table is likely to contain many entries, polling of this objec…
1.3.6.1.4.1.2352.2.24.1.1.2ScalarrbnSRProcessEventNotifyEnableread-writecurrentIndicates whether rbnSRProcessEvent notification should be generated for this system.
1.3.6.1.4.1.2352.2.24.1.1.3TablerbnSRProcessNotifyTablenot-accessiblecurrentA list of process event notifications since the agent was last re-initialized. If no process event has ever been generated, this table is empty, i.e., has zero…
1.3.6.1.4.1.2352.2.24.1.1.3.1RowrbnSRProcessNotifyEntrynot-accessiblecurrentInformation about a death/birth process event notification which was last generated on the particular process.
1.3.6.1.4.1.2352.2.24.1.1.3.1.1ColumnrbnSRProcessNotifyProcNamenot-accessiblecurrentA human readable name identifying a particular process in the system.
1.3.6.1.4.1.2352.2.24.1.1.3.1.2ColumnrbnSRProcessNotifyPIDread-onlycurrentA decimal number uniquely identifies the process. The value 0 indicates the process has not been started.
1.3.6.1.4.1.2352.2.24.1.1.3.1.3ColumnrbnSRProcessNotifyEventCauseread-onlycurrentThis identifies the cause of a process death/birth event. The value firstStart(1) indicates the process has been started the first time. The other values ident…
1.3.6.1.4.1.2352.2.24.1.1.3.1.4ColumnrbnSRProcessNotifyEventTyperead-onlycurrentThe type of event notification sent on the process described by this row of the table. The process event type death(1) indicates that the agent has been inform…
1.3.6.1.4.1.2352.2.24.1.1.3.1.5ColumnrbnSRProcessNumOfSpawnread-onlycurrentThe number of times the process has been spawned since the system was last initialized. Note that this is different from the restart of the network management …
1.3.6.1.4.1.2352.2.24.1.1.3.1.6ColumnrbnSRProcessNotifyLastTimeSentread-onlycurrentThe value of sysUpTime at the time this notification was last generated on the process.
1.3.6.1.4.1.2352.2.24.1.2NoderbnSRStorage
1.3.6.1.4.1.2352.2.24.1.2.1TablerbnSRStorageTablenot-accessiblecurrentThe (conceptual) table of long-term storage devices contained by the system. In particular, disk devices accessed remotely over a network are not included here.
1.3.6.1.4.1.2352.2.24.1.2.1.1RowrbnSRStorageEntrynot-accessiblecurrentA (conceptual) entry for one long-term storage device contained by the system.
1.3.6.1.4.1.2352.2.24.1.2.1.1.1ColumnrbnSRStorageIndexnot-accessiblecurrentA unique value for each long-term storage device contained by the system. The value for each physical storage device must remain constant at least from one re-…
1.3.6.1.4.1.2352.2.24.1.2.1.1.2ColumnrbnSRStorageDescrread-onlycurrentA textual description of this storage device, optionally including the device's manufacturer, revision, and its serial number.
1.3.6.1.4.1.2352.2.24.1.2.1.1.3ColumnrbnSRStorageMediaread-onlycurrentAn indication of the type of media used in this long-term storage device.
1.3.6.1.4.1.2352.2.24.1.2.1.1.4ColumnrbnSRStorageRemovableread-onlycurrentDenotes whether or not the storage media may be removed from the drive/slot.
1.3.6.1.4.1.2352.2.24.1.2.1.1.5ColumnrbnSRStorageSizeread-onlycurrentThe total size for this long-term storage device. If the media is removable and is currently removed, this value should be zero.
1.3.6.1.4.1.2352.2.24.1.2.1.1.6ColumnrbnSRStorageUtilizationread-onlycurrentThis object is the percent utilization of the storage space on a scale of 0 to 100 percent. The formula used to calculate the Utilization is as follows. used b…
1.3.6.1.4.1.2352.2.24.1.2.1.1.7ColumnrbnSRStorageSlotread-onlycurrentThe chassis slot number in which the controller card containing this storage device is present.
1.3.6.1.4.1.2352.2.24.1.2.1.1.8ColumnrbnSRStorageMountTimeread-onlycurrentThe value of sysUpTime when this storage device was last mounted.
1.3.6.1.4.1.2352.2.24.1.2.1.1.9ColumnrbnSRStorageStatusread-onlycurrentThe functional status of this storage device.
1.3.6.1.4.1.2352.2.24.1.2.1.1.10ColumnrbnSRStorageErrorsread-onlycurrentThe cumulative count of soft errors on this storage device.
1.3.6.1.4.1.2352.2.24.1.2.2TablerbnSseDiskStorageTablenot-accessiblecurrentFile Server System Blade is a card on the SmartEdge platform that manages data on hard disks connected to the card. This table provides details of these disks.
1.3.6.1.4.1.2352.2.24.1.2.2.1RowrbnSseDiskStorageEntrynot-accessiblecurrentA entry for the disk on the SSE.
1.3.6.1.4.1.2352.2.24.1.2.2.1.1ColumnrbnSseDiskSlotnot-accessiblecurrentThe chassis slot number in which the disk resides.
1.3.6.1.4.1.2352.2.24.1.2.2.1.2ColumnrbnSseDiskNumnot-accessiblecurrentThe disk number used to identity the disk.
1.3.6.1.4.1.2352.2.24.1.2.2.1.3ColumnrbnSseDiskStateread-onlycurrentOperational status of the disk.
1.3.6.1.4.1.2352.2.24.1.2.2.1.4ColumnrbnSseDiskSizeread-onlycurrentTotal size of the disk in GBytes.
1.3.6.1.4.1.2352.2.24.1.2.2.1.5ColumnrbnSseDiskUsedread-onlycurrentTotal disk space utilized in GBytes.
1.3.6.1.4.1.2352.2.24.1.3NoderbnSRSystem
1.3.6.1.4.1.2352.2.24.1.3.1ScalarrbnSRSystemUptimeread-onlycurrentThe amount of time since this system was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the upti…
1.3.6.1.4.1.2352.2.24.1.3.2ScalarrbnSRSystemDateread-writecurrentThe host's notion of the local date and time of day.
1.3.6.1.4.1.2352.2.24.1.4NoderbnPowerExceeded
1.3.6.1.4.1.2352.2.24.1.4.1ScalarrbnSRPowerExceededStatusaccessible-for-notifycurrentThe status of alarm when a controller card is inserted and results in more power being drawn than recommended. If an instance of this object has the value norm…
1.3.6.1.4.1.2352.2.24.1.5ScalarrbnSseDiskAlarmDateAndTimeaccessible-for-notifycurrentThe local date and time when the alarm was raised
1.3.6.1.4.1.2352.2.24.1.6ScalarrbnSseDiskAlarmSeverityaccessible-for-notifycurrentThe perceived severity of the alarm.
1.3.6.1.4.1.2352.2.24.1.7ScalarrbnSseDiskAlarmProbableCauseaccessible-for-notifycurrentThe probable cause for this alarm.
1.3.6.1.4.1.2352.2.24.1.8ScalarrbnSseDiskEventTypeaccessible-for-notifycurrentThe type of the alarm.
1.3.6.1.4.1.2352.2.24.1.9ScalarrbnSseDiskAlarmDescriptionaccessible-for-notifycurrentA text string which conveys additional information about the alarm.
1.3.6.1.4.1.2352.2.24.1.10NoderbnIssuObjects
1.3.6.1.4.1.2352.2.24.1.10.1ScalarrbnIssuStateaccessible-for-notifycurrentThe current state of the inservice system upgrade (ISSU).
1.3.6.1.4.1.2352.2.24.1.11NoderbnChassisGroup
1.3.6.1.4.1.2352.2.24.1.11.1ScalarrbnChassisAlarmIdaccessible-for-notifycurrentThe chassis alarm identifier
1.3.6.1.4.1.2352.2.24.1.11.2ScalarrbnChassisAlarmTypeaccessible-for-notifycurrentThe chassis alarm type.
1.3.6.1.4.1.2352.2.24.1.11.3ScalarrbnChassisAlarmDateAndTimeaccessible-for-notifycurrentThe local date and time when the chassis alarm was raised
1.3.6.1.4.1.2352.2.24.1.11.4ScalarrbnChassisAlarmDescriptionaccessible-for-notifycurrentA text string which conveys additional information about the chassis alarm.
1.3.6.1.4.1.2352.2.24.1.11.5ScalarrbnChassisAlarmProbableCauseaccessible-for-notifycurrentThe probable cause for the chassis alarm.
1.3.6.1.4.1.2352.2.24.1.11.6ScalarrbnChassisAlarmSeverityaccessible-for-notifycurrentThe perceived severity of the chassis alarm.
1.3.6.1.4.1.2352.2.24.2NoderbnSRMIBConformance
1.3.6.1.4.1.2352.2.24.2.1NoderbnSRMIBCompliances
1.3.6.1.4.1.2352.2.24.2.1.1CompliancerbnSRMIBCompliance1read-onlyobsoleteThe requirements for conformance to the Redback System Resources MIB. rbnSRMIBCompliance2 replaces this compliance.
1.3.6.1.4.1.2352.2.24.2.1.2CompliancerbnSRMIBCompliance2read-onlydeprecatedThe requirements for conformance to the Redback System Resources MIB. rbnSRMIBCompliance3 replaces this compliance.
1.3.6.1.4.1.2352.2.24.2.1.3CompliancerbnSRMIBCompliance3read-onlydeprecatedThe requirements for conformance to the Redback System Resources MIB.
1.3.6.1.4.1.2352.2.24.2.1.4CompliancerbnSRMIBCompliance4read-onlydeprecatedThe requirements for conformance to the Redback System Resources MIB.
1.3.6.1.4.1.2352.2.24.2.1.5CompliancerbnSRMIBComplianceread-onlydeprecatedThe requirements for conformance to the Redback System Resources MIB.
1.3.6.1.4.1.2352.2.24.2.1.6CompliancerbnSRMIBCompliance6read-onlycurrentThe requirements for conformance to the System Resources MIB.
1.3.6.1.4.1.2352.2.24.2.2NoderbnSRMIBGroups
1.3.6.1.4.1.2352.2.24.2.2.1GrouprbnSRProcessNotifyGroupcurrentA collection of objects providing for remote monitoring of the system process event notification.
1.3.6.1.4.1.2352.2.24.2.2.2GrouprbnSRStorageGroupdeprecatedThe System Resources Storage Group. Replaced by rbnSRStorageGroup2.
1.3.6.1.4.1.2352.2.24.2.2.3GrouprbnSRProcessEventNotificationGroupobsoleteA collection of notifications that may be implemented for managing the system process. Replaced by rbnSRNotificationGroup.
1.3.6.1.4.1.2352.2.24.2.2.4GrouprbnSRNotificationGroupdeprecatedA collection of notifications that are implemented for managing the system processes. Replaced by rbnSRNotificationGroup2.
1.3.6.1.4.1.2352.2.24.2.2.5GrouprbnSRStorageGroup2currentThe System Resources Storage Group.
1.3.6.1.4.1.2352.2.24.2.2.6GrouprbnSRNotificationGroup2currentA collection of notifications that may be implemented for managing the system resources.
1.3.6.1.4.1.2352.2.24.2.2.7GrouprbnSRSystemGroupcurrentA collection of objects providing for remote monitoring of the system information.
1.3.6.1.4.1.2352.2.24.2.2.8GrouprbnSRPowerNotifyGroupcurrentA notification that may be implemented for tracking power capacity exceeding limit.
1.3.6.1.4.1.2352.2.24.2.2.9GrouprbnSRPowerExceededGroupcurrentA group providing for status of the power capacity exceeding limit.
1.3.6.1.4.1.2352.2.24.2.2.10GrouprbnSseDiskGroupcurrentA group providing SSE disk details.
1.3.6.1.4.1.2352.2.24.2.2.11GrouprbnSseDiskEventObjectGroupcurrentA collection of rbnSseDisk notification objects.
1.3.6.1.4.1.2352.2.24.2.2.12GrouprbnSseDiskNotifyGroupcurrentNotifications that are implemented for SSE disks.
1.3.6.1.4.1.2352.2.24.2.2.13GrouprbnIssuGroupcurrentA collection of ISSU notification objects.
1.3.6.1.4.1.2352.2.24.2.2.14GrouprbnIssuNotifyGroupcurrentNotifications that are implemented for ISSU.
1.3.6.1.4.1.2352.2.24.2.2.15GrouprbnChassisEventObjectGroupcurrentA collection of rbnChassis notification objects.