MIB Viewer

READYDATAOS-MIB

82 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212OBJECT-TYPE
RFC-1215TRAP-TYPE
RFC1155-SMIenterprises
RFC1213-MIBDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.4526Nodenetgear
1.3.6.1.4.1.4526.22NodengNasManager
1.3.6.1.4.1.4526.22.1ScalarnasMgrSoftwareVersionread-onlycurrentVersion information for the ReadyDATAOS ngNasManager software.
1.3.6.1.4.1.4526.22.3TablediskTablenot-accessiblemandatoryA table of physical disks attached to the storage device.
1.3.6.1.4.1.4526.22.3.1RowdiskEntrynot-accessiblemandatoryAn entry in the physical disk table.
1.3.6.1.4.1.4526.22.3.1.1ColumndiskNumberread-onlymandatoryInstance number of the disk entry.
1.3.6.1.4.1.4526.22.3.1.2ColumndiskIDread-onlymandatoryDisk ID.
1.3.6.1.4.1.4526.22.3.1.3ColumndiskSlotNameread-onlymandatoryThe slot location of the disk.
1.3.6.1.4.1.4526.22.3.1.4ColumndiskSerialread-onlymandatoryDisk Serial number.
1.3.6.1.4.1.4526.22.3.1.5ColumndiskModelread-onlymandatoryThe disk drive's model name.
1.3.6.1.4.1.4526.22.3.1.6ColumnataErrorread-onlymandatoryATA error number for this disk from S.M.A.R.T read.
1.3.6.1.4.1.4526.22.3.1.7ColumndiskCapacityread-onlymandatoryThe capacity of the disk in bytes.
1.3.6.1.4.1.4526.22.3.1.8ColumndiskInterfaceread-onlymandatoryThe disk connect interface, such as SATA, USB etc.
1.3.6.1.4.1.4526.22.3.1.9ColumndiskStateread-onlymandatoryThe current state of the Disk. Possible states: 0: Online 1: Offline
1.3.6.1.4.1.4526.22.3.1.10ColumndiskTemperatureread-onlymandatorytemperature of this disk(in Fahrenheit unit).
1.3.6.1.4.1.4526.22.4TablefanTablenot-accessiblecurrent
1.3.6.1.4.1.4526.22.4.1RowfanEntrynot-accessiblecurrent
1.3.6.1.4.1.4526.22.4.1.1ColumnfanNumberread-onlymandatoryInstance number of this fan entry.
1.3.6.1.4.1.4526.22.4.1.2ColumnfanRPMread-onlymandatoryThe current speed of the fan.
1.3.6.1.4.1.4526.22.4.1.3ColumnfanStatusread-onlymandatoryThe status of Fan
1.3.6.1.4.1.4526.22.4.1.4ColumnfanTyperead-onlymandatoryWhat fan is used for: SYS: for system board CPU: for CPU CASE: for system case
1.3.6.1.4.1.4526.22.5TabletemperatureTablenot-accessiblemandatory
1.3.6.1.4.1.4526.22.5.1RowtemperatureEntrynot-accessiblemandatory
1.3.6.1.4.1.4526.22.5.1.1ColumntemperatureNumberread-onlymandatoryInstance number of this temperature probe entry.
1.3.6.1.4.1.4526.22.5.1.2ColumntemperatureValueread-onlymandatoryThe current temperature of this probe (in Fahrenheit unit).
1.3.6.1.4.1.4526.22.5.1.3ColumntemperatureTyoeread-onlymandatoryThe current temperature refer to
1.3.6.1.4.1.4526.22.5.1.4ColumntemperatureMinread-onlymandatoryThe min temperature of this probe (in Fahrenheit unit).
1.3.6.1.4.1.4526.22.5.1.5ColumntemperatureMaxread-onlymandatoryThe max temperature of this probe (in Fahrenheit unit).
1.3.6.1.4.1.4526.22.7TablevolumeTablenot-accessiblemandatoryA table of active volumes on the storage device.
1.3.6.1.4.1.4526.22.7.1RowvolumeEntrynot-accessiblemandatoryAn entry in the volume table.
1.3.6.1.4.1.4526.22.7.1.1ColumnvolumeNumberread-onlymandatoryInstance number of the volume entry.
1.3.6.1.4.1.4526.22.7.1.2ColumnvolumeNameread-onlymandatoryThe name of the volume.
1.3.6.1.4.1.4526.22.7.1.3ColumnvolumeRAIDLevelread-onlymandatoryThe RAID level of the volume.
1.3.6.1.4.1.4526.22.7.1.4ColumnvolumeStatusread-onlymandatoryThe severity of the volume. Possible values: 1: ONLINE 2: OFFLINE 3: DEGRADED 4: FAULTED 5: REMOVED 6: UNAVAILABLE 7: UNKNOWN
1.3.6.1.4.1.4526.22.7.1.5ColumnvolumeSizeread-onlymandatoryThe size of the volume in megabytes.
1.3.6.1.4.1.4526.22.7.1.6ColumnvolumeFreeSpaceread-onlymandatoryFree space on the volume in megabytes.
1.3.6.1.4.1.4526.22.8TablepsuTablenot-accessiblemandatory
1.3.6.1.4.1.4526.22.8.1RowpsuEntryread-onlymandatory
1.3.6.1.4.1.4526.22.8.1.1ColumnpsuNumberread-onlymandatoryInstance number of this power supply unit.
1.3.6.1.4.1.4526.22.8.1.2ColumnpsuDescread-onlymandatoryThe description of this PSU.
1.3.6.1.4.1.4526.22.8.1.3ColumnpsuStatusread-onlymandatoryThe current PSU status.
1.3.6.1.4.1.4526.22.200NodearyMgrEvts
1.3.6.1.4.1.4526.22.200.201ScalarcontrollerNameEvread-onlymandatoryController Name for which trap is generated.
1.3.6.1.4.1.4526.22.200.202ScalarchannelNumberEvread-onlymandatoryChannel Number for which trap is generated.
1.3.6.1.4.1.4526.22.200.203ScalartargetIDEvread-onlymandatorySCSI ID of the device for which trap is generated.
1.3.6.1.4.1.4526.22.200.204ScalarvirtualDiskNameEvread-onlymandatoryVirtual Disk for which trap is generated.
1.3.6.1.4.1.4526.22.200.205ScalararrayDiskNameEvread-onlymandatoryArray Disk for which trap is generated.
1.3.6.1.4.1.4526.22.200.206ScalaroldVDConfigEvread-onlymandatoryCurrent Virtual Disk configuration for which trap is generated
1.3.6.1.4.1.4526.22.200.207ScalarnewVDConfigEvread-onlymandatoryNew Virtual Disk configuration for which trap is generated.
1.3.6.1.4.1.4526.22.200.208ScalarenclosureNumberEvread-onlymandatoryEnclosure Number for which trap is generated.
1.3.6.1.4.1.4526.22.200.209ScalarunitNumberEvread-onlymandatoryUnit Number for which trap is generated. (Fan, Power Supply, Temperature Probe)
1.3.6.1.4.1.4526.22.200.210ScalarenclosureNameEvread-onlymandatoryEnclosure Name for which trap is generated.
1.3.6.1.4.1.4526.22.200.211ScalarunitNameEvread-onlymandatoryUnit Number for which trap is generated. (Fan, Power Supply, Temperature Probe)
1.3.6.1.4.1.4526.22.200.212ScalartimeEvread-onlymandatoryAmount of time specified in the trap message.
1.3.6.1.4.1.4526.22.200.213ScalarvolumeNameEvread-onlymandatoryVolume Drive Letter for which trap is generated.
1.3.6.1.4.1.4526.22.300NodenasTraps
1.3.6.1.4.1.4526.22.300.10NodefanFailureFan failure, fan speed is %s.
1.3.6.1.4.1.4526.22.300.20NodetempFailureTemperature sensor reports out of normal range.
1.3.6.1.4.1.4526.22.300.30NodepowerVoltageSystem power is out of spec, please check system status!
1.3.6.1.4.1.4526.22.300.40NoderaidEventNoticeRAID event detected!
1.3.6.1.4.1.4526.22.300.50NodesnapshotEventNoticeSnapshot event detected!
1.3.6.1.4.1.4526.22.300.60NodehotplugDiskNoticeHotplug disk event detected!
1.3.6.1.4.1.4526.22.300.70NodeupsEventNoticeUPS status.
1.3.6.1.4.1.4526.22.300.80NodevolumeNoticeVolume is approaching capacity.
1.3.6.1.4.1.4526.22.300.90NodediskTempWarningDisk temperature warning.
1.3.6.1.4.1.4526.22.300.100NodebackupNoticeBackup job status.
1.3.6.1.4.1.4526.22.300.110NodediskSmartWarningDisk SMART warning.
1.3.6.1.4.1.4526.22.300.120NodepsuWarningPower supply unit warning.
1.3.6.1.4.1.4526.22.400ScalarfanFailureMesgread-onlycurrentFailure message for Fan
1.3.6.1.4.1.4526.22.401ScalartempFailureMesgread-onlycurrentFailure message for system temperature
1.3.6.1.4.1.4526.22.402ScalarpowerVoltageMesgread-onlycurrentFailure message for system power
1.3.6.1.4.1.4526.22.403ScalarraidEventNoticeMesgread-onlycurrentRAID hotplug event message
1.3.6.1.4.1.4526.22.404ScalarsnapshotEventNoticeMesgread-onlycurrentSnapshot messages
1.3.6.1.4.1.4526.22.405ScalarupsEventNoticeMesgread-onlycurrentUPS status message
1.3.6.1.4.1.4526.22.406ScalarhotplugDiskNoticeMesgread-onlycurrentDisk hotplug event messages
1.3.6.1.4.1.4526.22.407ScalarvolumeNoticeMesgread-onlycurrentDisk usage warning
1.3.6.1.4.1.4526.22.408ScalardiskTempWarningMesgread-onlycurrentDisk temperature warning messages
1.3.6.1.4.1.4526.22.409ScalarbackupNoticeMesgread-onlycurrentBackup job status messages
1.3.6.1.4.1.4526.22.410ScalardiskSmartWarningMesgread-onlycurrentDisk SMART messages
1.3.6.1.4.1.4526.22.411ScalarpsuWarningMesgread-onlycurrentPSU status messages
1.3.6.1.4.1.4526.100NodeproductID
1.3.6.1.4.1.4526.100.15NodeReadyDATAOS