READYDATAOS-MIB
82 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | enterprises |
| RFC1213-MIB | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4526 | Nodenetgear | |||
| 1.3.6.1.4.1.4526.22 | NodengNasManager | |||
| 1.3.6.1.4.1.4526.22.1 | ScalarnasMgrSoftwareVersion | read-only | current | Version information for the ReadyDATAOS ngNasManager software. |
| 1.3.6.1.4.1.4526.22.3 | TablediskTable | not-accessible | mandatory | A table of physical disks attached to the storage device. |
| 1.3.6.1.4.1.4526.22.3.1 | RowdiskEntry | not-accessible | mandatory | An entry in the physical disk table. |
| 1.3.6.1.4.1.4526.22.3.1.1 | ColumndiskNumber | read-only | mandatory | Instance number of the disk entry. |
| 1.3.6.1.4.1.4526.22.3.1.2 | ColumndiskID | read-only | mandatory | Disk ID. |
| 1.3.6.1.4.1.4526.22.3.1.3 | ColumndiskSlotName | read-only | mandatory | The slot location of the disk. |
| 1.3.6.1.4.1.4526.22.3.1.4 | ColumndiskSerial | read-only | mandatory | Disk Serial number. |
| 1.3.6.1.4.1.4526.22.3.1.5 | ColumndiskModel | read-only | mandatory | The disk drive's model name. |
| 1.3.6.1.4.1.4526.22.3.1.6 | ColumnataError | read-only | mandatory | ATA error number for this disk from S.M.A.R.T read. |
| 1.3.6.1.4.1.4526.22.3.1.7 | ColumndiskCapacity | read-only | mandatory | The capacity of the disk in bytes. |
| 1.3.6.1.4.1.4526.22.3.1.8 | ColumndiskInterface | read-only | mandatory | The disk connect interface, such as SATA, USB etc. |
| 1.3.6.1.4.1.4526.22.3.1.9 | ColumndiskState | read-only | mandatory | The current state of the Disk. Possible states: 0: Online 1: Offline |
| 1.3.6.1.4.1.4526.22.3.1.10 | ColumndiskTemperature | read-only | mandatory | temperature of this disk(in Fahrenheit unit). |
| 1.3.6.1.4.1.4526.22.4 | TablefanTable | not-accessible | current | |
| 1.3.6.1.4.1.4526.22.4.1 | RowfanEntry | not-accessible | current | |
| 1.3.6.1.4.1.4526.22.4.1.1 | ColumnfanNumber | read-only | mandatory | Instance number of this fan entry. |
| 1.3.6.1.4.1.4526.22.4.1.2 | ColumnfanRPM | read-only | mandatory | The current speed of the fan. |
| 1.3.6.1.4.1.4526.22.4.1.3 | ColumnfanStatus | read-only | mandatory | The status of Fan |
| 1.3.6.1.4.1.4526.22.4.1.4 | ColumnfanType | read-only | mandatory | What fan is used for: SYS: for system board CPU: for CPU CASE: for system case |
| 1.3.6.1.4.1.4526.22.5 | TabletemperatureTable | not-accessible | mandatory | |
| 1.3.6.1.4.1.4526.22.5.1 | RowtemperatureEntry | not-accessible | mandatory | |
| 1.3.6.1.4.1.4526.22.5.1.1 | ColumntemperatureNumber | read-only | mandatory | Instance number of this temperature probe entry. |
| 1.3.6.1.4.1.4526.22.5.1.2 | ColumntemperatureValue | read-only | mandatory | The current temperature of this probe (in Fahrenheit unit). |
| 1.3.6.1.4.1.4526.22.5.1.3 | ColumntemperatureTyoe | read-only | mandatory | The current temperature refer to |
| 1.3.6.1.4.1.4526.22.5.1.4 | ColumntemperatureMin | read-only | mandatory | The min temperature of this probe (in Fahrenheit unit). |
| 1.3.6.1.4.1.4526.22.5.1.5 | ColumntemperatureMax | read-only | mandatory | The max temperature of this probe (in Fahrenheit unit). |
| 1.3.6.1.4.1.4526.22.7 | TablevolumeTable | not-accessible | mandatory | A table of active volumes on the storage device. |
| 1.3.6.1.4.1.4526.22.7.1 | RowvolumeEntry | not-accessible | mandatory | An entry in the volume table. |
| 1.3.6.1.4.1.4526.22.7.1.1 | ColumnvolumeNumber | read-only | mandatory | Instance number of the volume entry. |
| 1.3.6.1.4.1.4526.22.7.1.2 | ColumnvolumeName | read-only | mandatory | The name of the volume. |
| 1.3.6.1.4.1.4526.22.7.1.3 | ColumnvolumeRAIDLevel | read-only | mandatory | The RAID level of the volume. |
| 1.3.6.1.4.1.4526.22.7.1.4 | ColumnvolumeStatus | read-only | mandatory | The severity of the volume. Possible values: 1: ONLINE 2: OFFLINE 3: DEGRADED 4: FAULTED 5: REMOVED 6: UNAVAILABLE 7: UNKNOWN |
| 1.3.6.1.4.1.4526.22.7.1.5 | ColumnvolumeSize | read-only | mandatory | The size of the volume in megabytes. |
| 1.3.6.1.4.1.4526.22.7.1.6 | ColumnvolumeFreeSpace | read-only | mandatory | Free space on the volume in megabytes. |
| 1.3.6.1.4.1.4526.22.8 | TablepsuTable | not-accessible | mandatory | |
| 1.3.6.1.4.1.4526.22.8.1 | RowpsuEntry | read-only | mandatory | |
| 1.3.6.1.4.1.4526.22.8.1.1 | ColumnpsuNumber | read-only | mandatory | Instance number of this power supply unit. |
| 1.3.6.1.4.1.4526.22.8.1.2 | ColumnpsuDesc | read-only | mandatory | The description of this PSU. |
| 1.3.6.1.4.1.4526.22.8.1.3 | ColumnpsuStatus | read-only | mandatory | The current PSU status. |
| 1.3.6.1.4.1.4526.22.200 | NodearyMgrEvts | |||
| 1.3.6.1.4.1.4526.22.200.201 | ScalarcontrollerNameEv | read-only | mandatory | Controller Name for which trap is generated. |
| 1.3.6.1.4.1.4526.22.200.202 | ScalarchannelNumberEv | read-only | mandatory | Channel Number for which trap is generated. |
| 1.3.6.1.4.1.4526.22.200.203 | ScalartargetIDEv | read-only | mandatory | SCSI ID of the device for which trap is generated. |
| 1.3.6.1.4.1.4526.22.200.204 | ScalarvirtualDiskNameEv | read-only | mandatory | Virtual Disk for which trap is generated. |
| 1.3.6.1.4.1.4526.22.200.205 | ScalararrayDiskNameEv | read-only | mandatory | Array Disk for which trap is generated. |
| 1.3.6.1.4.1.4526.22.200.206 | ScalaroldVDConfigEv | read-only | mandatory | Current Virtual Disk configuration for which trap is generated |
| 1.3.6.1.4.1.4526.22.200.207 | ScalarnewVDConfigEv | read-only | mandatory | New Virtual Disk configuration for which trap is generated. |
| 1.3.6.1.4.1.4526.22.200.208 | ScalarenclosureNumberEv | read-only | mandatory | Enclosure Number for which trap is generated. |
| 1.3.6.1.4.1.4526.22.200.209 | ScalarunitNumberEv | read-only | mandatory | Unit Number for which trap is generated. (Fan, Power Supply, Temperature Probe) |
| 1.3.6.1.4.1.4526.22.200.210 | ScalarenclosureNameEv | read-only | mandatory | Enclosure Name for which trap is generated. |
| 1.3.6.1.4.1.4526.22.200.211 | ScalarunitNameEv | read-only | mandatory | Unit Number for which trap is generated. (Fan, Power Supply, Temperature Probe) |
| 1.3.6.1.4.1.4526.22.200.212 | ScalartimeEv | read-only | mandatory | Amount of time specified in the trap message. |
| 1.3.6.1.4.1.4526.22.200.213 | ScalarvolumeNameEv | read-only | mandatory | Volume Drive Letter for which trap is generated. |
| 1.3.6.1.4.1.4526.22.300 | NodenasTraps | |||
| 1.3.6.1.4.1.4526.22.300.10 | NodefanFailure | Fan failure, fan speed is %s. | ||
| 1.3.6.1.4.1.4526.22.300.20 | NodetempFailure | Temperature sensor reports out of normal range. | ||
| 1.3.6.1.4.1.4526.22.300.30 | NodepowerVoltage | System power is out of spec, please check system status! | ||
| 1.3.6.1.4.1.4526.22.300.40 | NoderaidEventNotice | RAID event detected! | ||
| 1.3.6.1.4.1.4526.22.300.50 | NodesnapshotEventNotice | Snapshot event detected! | ||
| 1.3.6.1.4.1.4526.22.300.60 | NodehotplugDiskNotice | Hotplug disk event detected! | ||
| 1.3.6.1.4.1.4526.22.300.70 | NodeupsEventNotice | UPS status. | ||
| 1.3.6.1.4.1.4526.22.300.80 | NodevolumeNotice | Volume is approaching capacity. | ||
| 1.3.6.1.4.1.4526.22.300.90 | NodediskTempWarning | Disk temperature warning. | ||
| 1.3.6.1.4.1.4526.22.300.100 | NodebackupNotice | Backup job status. | ||
| 1.3.6.1.4.1.4526.22.300.110 | NodediskSmartWarning | Disk SMART warning. | ||
| 1.3.6.1.4.1.4526.22.300.120 | NodepsuWarning | Power supply unit warning. | ||
| 1.3.6.1.4.1.4526.22.400 | ScalarfanFailureMesg | read-only | current | Failure message for Fan |
| 1.3.6.1.4.1.4526.22.401 | ScalartempFailureMesg | read-only | current | Failure message for system temperature |
| 1.3.6.1.4.1.4526.22.402 | ScalarpowerVoltageMesg | read-only | current | Failure message for system power |
| 1.3.6.1.4.1.4526.22.403 | ScalarraidEventNoticeMesg | read-only | current | RAID hotplug event message |
| 1.3.6.1.4.1.4526.22.404 | ScalarsnapshotEventNoticeMesg | read-only | current | Snapshot messages |
| 1.3.6.1.4.1.4526.22.405 | ScalarupsEventNoticeMesg | read-only | current | UPS status message |
| 1.3.6.1.4.1.4526.22.406 | ScalarhotplugDiskNoticeMesg | read-only | current | Disk hotplug event messages |
| 1.3.6.1.4.1.4526.22.407 | ScalarvolumeNoticeMesg | read-only | current | Disk usage warning |
| 1.3.6.1.4.1.4526.22.408 | ScalardiskTempWarningMesg | read-only | current | Disk temperature warning messages |
| 1.3.6.1.4.1.4526.22.409 | ScalarbackupNoticeMesg | read-only | current | Backup job status messages |
| 1.3.6.1.4.1.4526.22.410 | ScalardiskSmartWarningMesg | read-only | current | Disk SMART messages |
| 1.3.6.1.4.1.4526.22.411 | ScalarpsuWarningMesg | read-only | current | PSU status messages |
| 1.3.6.1.4.1.4526.100 | NodeproductID | |||
| 1.3.6.1.4.1.4526.100.15 | NodeReadyDATAOS |