MIB Viewer

REDLINE-AN80I-MIB

75 objects
This MIB module contains object definitions applicable only to Redline AN80i switched device.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.10728.2.1.3IdentityredlineAn80iMibThis MIB module contains object definitions applicable only to Redline AN80i switched device.
1.3.6.1.4.1.10728.2.1.3.0NoderedlineAn80iTrapDefinitions
1.3.6.1.4.1.10728.2.1.3.0.1Notificationan80iPswdChangeFailTrapcurrentAn event to report the failure of a password change.
1.3.6.1.4.1.10728.2.1.3.0.2Notificationan80iFirmwareConfigFailTrapcurrentAn event to report the failure of a firmware config.
1.3.6.1.4.1.10728.2.1.3.0.3Notificationan80iEepromCorruptedTrapcurrentAn event to report the corruption of the EEPROM.
1.3.6.1.4.1.10728.2.1.3.0.4Notificationan80iHardwareFailTrapcurrentAn event to report the hardware failure.
1.3.6.1.4.1.10728.2.1.3.0.5Notificationan80iSaveConfigTrapcurrentAn event to report the saving of configuration
1.3.6.1.4.1.10728.2.1.3.0.6Notificationan80iDFSEventTrapcurrentAn event to report the radar frequency detection
1.3.6.1.4.1.10728.2.1.3.0.7Notificationan80iIdChangedTrapcurrentEvent that reports the modification in the configuration of an ID.
1.3.6.1.4.1.10728.2.1.3.0.8Notificationan80iSWUpgradeFailedcurrentEvent that reports the failure of a software upgrade opration.
1.3.6.1.4.1.10728.2.1.3.0.9Notificationan80iSWUpgradeSuccesscurrentEvent that reports the success of a software upgrade opration.
1.3.6.1.4.1.10728.2.1.3.1NoderedlineAn80iPtpPmpObjects
1.3.6.1.4.1.10728.2.1.3.1.1NoderedlineAn80iSystemObjects
1.3.6.1.4.1.10728.2.1.3.1.1.1Tablean80iOptionsKeyTablenot-accessiblecurrentThis table contains options key information. The maximum number of configured options key is 2.
1.3.6.1.4.1.10728.2.1.3.1.1.1.1Rowan80iOptionsKeyEntrynot-accessiblecurrentThis table provides one row for each option key defined in the AN80i system
1.3.6.1.4.1.10728.2.1.3.1.1.1.1.1Columnan80iOptionsKeyIdnot-accessiblecurrentThe Options Key Identifier.
1.3.6.1.4.1.10728.2.1.3.1.1.1.1.2Columnan80iOptionsKeyread-createcurrentThe options key value.
1.3.6.1.4.1.10728.2.1.3.1.1.1.1.3Columnan80iOptionsKeyStatusread-createcurrentThis object is used to ctivate and deactivate rows in the an80iOptionsKeyTable table. There will be only two rows in the table and only one will be active. Whe…
1.3.6.1.4.1.10728.2.1.3.1.1.2Scalaran80iHardwareTyperead-onlycurrentThe type/version/revision of the hardware.
1.3.6.1.4.1.10728.2.1.3.1.1.3Scalaran80iRadioTyperead-onlycurrentThe radio type.
1.3.6.1.4.1.10728.2.1.3.1.1.4Scalaran80iSaveConfigread-writecurrentThis object will save the configuration in the nonvolatile memory and will activate the new configuration.
1.3.6.1.4.1.10728.2.1.3.1.1.5Scalaran80iActivateConfigread-writecurrentThis object will activate the new configuration without saving it in the nonvolatile memory. If after this event it will elapse more than 5 minutes and no save…
1.3.6.1.4.1.10728.2.1.3.1.2NoderedlineAn80iWirelesObjects
1.3.6.1.4.1.10728.2.1.3.1.2.1Scalaran80iAntennaAllignmentModeread-writecurrentSpecifies if the antenna alignment buzzer is enabled or not. In the future, new alignment methods may be added.
1.3.6.1.4.1.10728.2.1.3.1.2.2Scalaran80iCurrTxPowerread-onlycurrentThe actual Tx Power of the AN-80i Node.
1.3.6.1.4.1.10728.2.1.3.1.2.3Scalaran80iChannelAutoScanread-writecurrentSpecifies if the frequency auto-scanning feature is enabled
1.3.6.1.4.1.10728.2.1.3.1.2.4Scalaran80iCurrFrequencyread-onlycurrentThe central frequency on which the equipment operates. If the auto-scanning feature is enabled then this may be different than the an80iOPeratingFrequency. [KH…
1.3.6.1.4.1.10728.2.1.3.1.2.5Scalaran80iOPeratingFrequencyread-writecurrentSpecifies the operating frequency of the system [KHz].
1.3.6.1.4.1.10728.2.1.3.1.2.6Scalaran80iMaxTxPowerread-writecurrentThe Tx Power of the AN-80i. Specifies the power level of the system, which is preset at the factory and should not be altered. In the event that this parameter…
1.3.6.1.4.1.10728.2.1.3.1.2.7Scalaran80iSystemModeread-writecurrent1 = PMP Slave, 2 = PTP Master, 3 = PMP Slave, 4 = PMP Master
1.3.6.1.4.1.10728.2.1.3.1.2.8Scalaran80iRFStatusCoderead-onlycurrentSpecifies the Error Code for the RF Interface.
1.3.6.1.4.1.10728.2.1.3.1.2.9Scalaran80iDFSActionread-writecurrentAction taken when a radar is detected on the same frequency.
1.3.6.1.4.1.10728.2.1.3.1.2.10Scalaran80iAntennaGainread-writecurrentThe gain of the antenna attached to the system.
1.3.6.1.4.1.10728.2.1.3.1.2.11Scalaran80iActiveRFLinksread-onlycurrentThe actual number of provisioned links.
1.3.6.1.4.1.10728.2.1.3.1.2.12Scalaran80iAtpControlread-writecurrentEnable/disable the automatic Tx power control.
1.3.6.1.4.1.10728.2.1.3.1.2.13Scalaran80iTurboModeControlread-writecurrentEnable/disable the turbo mode. In this mode the system uses a 40MHz channel (20 MHz in normal mode).
1.3.6.1.4.1.10728.2.1.3.1.2.14Scalaran80iChannelWidthread-writecurrentThe width of the channel.
1.3.6.1.4.1.10728.2.1.3.1.3NoderedlineAn80iEthernetObjects
1.3.6.1.4.1.10728.2.1.3.1.3.1Scalaran80iEtherPortConnread-writecurrentSpecifies Ethernet port connection auto(1), mdi(2) or mdix(3)
1.3.6.1.4.1.10728.2.1.3.1.3.2Scalaran80iEtherPortModeread-writecurrentThe attribute specifies the Ethernet LED status of the AN80i.
1.3.6.1.4.1.10728.2.1.3.1.3.3Scalaran80iFlowControlread-writecurrentThis object specifies if flow control is enabled or not.
1.3.6.1.4.1.10728.2.1.3.1.3.4Scalaran80iLowLatencyModeread-writecurrentThis object specifies if prioritized low latency mode is enabled or not.
1.3.6.1.4.1.10728.2.1.3.1.3.5Scalaran80iEthernetFollowsWirelessread-writecurrentThis object specifies if the Ethernet follows wireless mode is enabled or not.
1.3.6.1.4.1.10728.2.1.3.1.3.6Scalaran80iEthernetFollowsWirelessTimeoutread-writecurrentThis object specifies if the timeout (seconds) for the Ethernet follows wireless mode (0=infinite).
1.3.6.1.4.1.10728.2.1.3.1.4NoderedlineAn80iManagObjects
1.3.6.1.4.1.10728.2.1.3.1.4.1Scalaran80iHttpAccessread-writecurrentThis object specifies if Http Access is enabled or not.
1.3.6.1.4.1.10728.2.1.3.1.4.2Scalaran80iTelnetAccessread-writecurrentThis object specifies if Telnet Access is enabled or not.
1.3.6.1.4.1.10728.2.1.3.1.4.3Scalaran80iTelnetPortread-writecurrentThis object specifies the Telnet port number.
1.3.6.1.4.1.10728.2.1.3.1.5NoderedlineAn80iSWUpgradeObjects
1.3.6.1.4.1.10728.2.1.3.1.5.1Scalaran80iSwDownloadTftpAddressTyperead-writecurrentThe INET address type of the software upgrade TFTP server. IPv4 type supported only.
1.3.6.1.4.1.10728.2.1.3.1.5.2Scalaran80iSwDownloadTftpAddressread-writecurrentThe INET address of the TFTP server.
1.3.6.1.4.1.10728.2.1.3.1.5.3Scalaran80iSwDownloadTftpFileread-writecurrentThe image file name as required by the TFTP server.
1.3.6.1.4.1.10728.2.1.3.1.5.4Scalaran80iSwDownloadStatusread-onlycurrentThe status of the current software download.
1.3.6.1.4.1.10728.2.1.3.1.5.5Scalaran80iSwDownloadControlread-writecurrentTrigger software upgrade
1.3.6.1.4.1.10728.2.1.3.2NoderedlineAn80iPmpObjects
1.3.6.1.4.1.10728.2.1.3.2.1NoderedlineAn80iPmpWirelesObjects
1.3.6.1.4.1.10728.2.1.3.2.1.1Scalaran80iRegistrationPeriodread-writecurrentNumber of frames between two consecutive registration periods.
1.3.6.1.4.1.10728.2.1.3.2.1.2Scalaran80iMaximumDistanceread-writecurrentMaximum distance in km between the sector controller and one subscriber station.
1.3.6.1.4.1.10728.2.1.3.2.1.3Scalaran80iRegisteredStationsread-onlycurrentThe number of registered stations on the sector controller.
1.3.6.1.4.1.10728.2.1.3.2.1.4Scalaran80iRegisteredConnectionsread-onlycurrentThe number of registered connections on the sector controller.
1.3.6.1.4.1.10728.2.1.3.2.1.5Scalaran80iMaxIdread-onlycurrentThe maximum number of ID used to identify links, connections and groups
1.3.6.1.4.1.10728.2.1.3.2.1.6Scalaran80iNextAvailIdread-onlycurrentThe next available ID from the ID pool which is not grater then that defined in 'an80iMaxId'
1.3.6.1.4.1.10728.2.1.3.2.1.7Scalaran80iLastModifIdread-onlycurrentThe last modified ID from the ID pool which is not grater then that defined in 'an80iMaxId'
1.3.6.1.4.1.10728.2.1.3.2.1.8Scalaran80iSaveIdConfigurationread-writecurrentSave the ID table in the flash memory
1.3.6.1.4.1.10728.2.1.3.3NoderedlineAn80iPtpObjects
1.3.6.1.4.1.10728.2.1.3.3.1NoderedlineAn80iPtpSystemObjects
1.3.6.1.4.1.10728.2.1.3.3.1.1Scalaran80iResetStatisticsread-writecurrentThis object resets wireless and Ethernet counters
1.3.6.1.4.1.10728.2.1.3.5NoderedlineAn80iConformance
1.3.6.1.4.1.10728.2.1.3.5.1NoderedlineAn80iGroups
1.3.6.1.4.1.10728.2.1.3.5.1.1GroupredlineAn80iPtpPmpGroupcurrentAN80i PTP/PMP objects.
1.3.6.1.4.1.10728.2.1.3.5.1.2GroupredlineAn80iPmpGroupcurrentAN80i PMP objects.
1.3.6.1.4.1.10728.2.1.3.5.1.3GroupredlineAn80iPtpGroupcurrentAN80i PTP objects.
1.3.6.1.4.1.10728.2.1.3.5.1.4GroupredlineAn80iNotificationGroupcurrentThe notifications which indicate specific events within the AN80i unit.
1.3.6.1.4.1.10728.2.1.3.5.2NoderedlineAn80iCompls
1.3.6.1.4.1.10728.2.1.3.5.2.1ComplianceredlineAn80iCompliancecurrentThe compliance statement for AN80i entities that implement this MIB module.