MIB Viewer

REDLINE-AN80I-MIB

75 objects
This MIB module contains object definitions applicable only to Redline AN80i switched device.
Imported Objects
INET-ADDRESS-MIBInetAddress InetAddressType InetPortNumber
REDLINE-MIBredlineSystem
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIInteger32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE TimeTicks
SNMPv2-TCDisplayString RowStatus
OIDNameAccessStatusDescription
1.3.6.1.4.1.10728.2.1.3IdentityredlineAn80iMibThis MIB module contains object definitions applicable only to Redline AN80i switched device.
1.3.6.1.4.1.10728.2.1.3.0NoderedlineAn80iTrapDefinitions
1.3.6.1.4.1.10728.2.1.3.0.1Notificationan80iPswdChangeFailTrapcurrentAn event to report the failure of a password change.
1.3.6.1.4.1.10728.2.1.3.0.2Notificationan80iFirmwareConfigFailTrapcurrentAn event to report the failure of a firmware config.
1.3.6.1.4.1.10728.2.1.3.0.3Notificationan80iEepromCorruptedTrapcurrentAn event to report the corruption of the EEPROM.
1.3.6.1.4.1.10728.2.1.3.0.4Notificationan80iHardwareFailTrapcurrentAn event to report the hardware failure.
1.3.6.1.4.1.10728.2.1.3.0.5Notificationan80iSaveConfigTrapcurrentAn event to report the saving of configuration
1.3.6.1.4.1.10728.2.1.3.0.6Notificationan80iDFSEventTrapcurrentAn event to report the radar frequency detection
1.3.6.1.4.1.10728.2.1.3.0.7Notificationan80iIdChangedTrapcurrentEvent that reports the modification in the configuration of an ID.
1.3.6.1.4.1.10728.2.1.3.0.8Notificationan80iSWUpgradeFailedcurrentEvent that reports the failure of a software upgrade opration.
1.3.6.1.4.1.10728.2.1.3.0.9Notificationan80iSWUpgradeSuccesscurrentEvent that reports the success of a software upgrade opration.
1.3.6.1.4.1.10728.2.1.3.1NoderedlineAn80iPtpPmpObjects
1.3.6.1.4.1.10728.2.1.3.1.1NoderedlineAn80iSystemObjects
1.3.6.1.4.1.10728.2.1.3.1.1.1Tablean80iOptionsKeyTablenot-accessiblecurrentThis table contains options key information. The maximum number of configured options key is 2.
1.3.6.1.4.1.10728.2.1.3.1.1.1.1Rowan80iOptionsKeyEntrynot-accessiblecurrentThis table provides one row for each option key defined in the AN80i system
1.3.6.1.4.1.10728.2.1.3.1.1.1.1.1Columnan80iOptionsKeyIdnot-accessiblecurrentThe Options Key Identifier.
1.3.6.1.4.1.10728.2.1.3.1.1.1.1.2Columnan80iOptionsKeyread-createcurrentThe options key value.
1.3.6.1.4.1.10728.2.1.3.1.1.1.1.3Columnan80iOptionsKeyStatusread-createcurrentThis object is used to ctivate and deactivate rows in the an80iOptionsKeyTable table. There will be only two rows in the table and only one will be active. Whe…
1.3.6.1.4.1.10728.2.1.3.1.1.2Scalaran80iHardwareTyperead-onlycurrentThe type/version/revision of the hardware.
1.3.6.1.4.1.10728.2.1.3.1.1.3Scalaran80iRadioTyperead-onlycurrentThe radio type.
1.3.6.1.4.1.10728.2.1.3.1.1.4Scalaran80iSaveConfigread-writecurrentThis object will save the configuration in the nonvolatile memory and will activate the new configuration.
1.3.6.1.4.1.10728.2.1.3.1.1.5Scalaran80iActivateConfigread-writecurrentThis object will activate the new configuration without saving it in the nonvolatile memory. If after this event it will elapse more than 5 minutes and no save…
1.3.6.1.4.1.10728.2.1.3.1.2NoderedlineAn80iWirelesObjects
1.3.6.1.4.1.10728.2.1.3.1.2.1Scalaran80iAntennaAllignmentModeread-writecurrentSpecifies if the antenna alignment buzzer is enabled or not. In the future, new alignment methods may be added.
1.3.6.1.4.1.10728.2.1.3.1.2.2Scalaran80iCurrTxPowerread-onlycurrentThe actual Tx Power of the AN-80i Node.
1.3.6.1.4.1.10728.2.1.3.1.2.3Scalaran80iChannelAutoScanread-writecurrentSpecifies if the frequency auto-scanning feature is enabled
1.3.6.1.4.1.10728.2.1.3.1.2.4Scalaran80iCurrFrequencyread-onlycurrentThe central frequency on which the equipment operates. If the auto-scanning feature is enabled then this may be different than the an80iOPeratingFrequency. [KH…
1.3.6.1.4.1.10728.2.1.3.1.2.5Scalaran80iOPeratingFrequencyread-writecurrentSpecifies the operating frequency of the system [KHz].
1.3.6.1.4.1.10728.2.1.3.1.2.6Scalaran80iMaxTxPowerread-writecurrentThe Tx Power of the AN-80i. Specifies the power level of the system, which is preset at the factory and should not be altered. In the event that this parameter…
1.3.6.1.4.1.10728.2.1.3.1.2.7Scalaran80iSystemModeread-writecurrent1 = PMP Slave, 2 = PTP Master, 3 = PMP Slave, 4 = PMP Master
1.3.6.1.4.1.10728.2.1.3.1.2.8Scalaran80iRFStatusCoderead-onlycurrentSpecifies the Error Code for the RF Interface.
1.3.6.1.4.1.10728.2.1.3.1.2.9Scalaran80iDFSActionread-writecurrentAction taken when a radar is detected on the same frequency.
1.3.6.1.4.1.10728.2.1.3.1.2.10Scalaran80iAntennaGainread-writecurrentThe gain of the antenna attached to the system.
1.3.6.1.4.1.10728.2.1.3.1.2.11Scalaran80iActiveRFLinksread-onlycurrentThe actual number of provisioned links.
1.3.6.1.4.1.10728.2.1.3.1.2.12Scalaran80iAtpControlread-writecurrentEnable/disable the automatic Tx power control.
1.3.6.1.4.1.10728.2.1.3.1.2.13Scalaran80iTurboModeControlread-writecurrentEnable/disable the turbo mode. In this mode the system uses a 40MHz channel (20 MHz in normal mode).
1.3.6.1.4.1.10728.2.1.3.1.2.14Scalaran80iChannelWidthread-writecurrentThe width of the channel.
1.3.6.1.4.1.10728.2.1.3.1.3NoderedlineAn80iEthernetObjects
1.3.6.1.4.1.10728.2.1.3.1.3.1Scalaran80iEtherPortConnread-writecurrentSpecifies Ethernet port connection auto(1), mdi(2) or mdix(3)
1.3.6.1.4.1.10728.2.1.3.1.3.2Scalaran80iEtherPortModeread-writecurrentThe attribute specifies the Ethernet LED status of the AN80i.
1.3.6.1.4.1.10728.2.1.3.1.3.3Scalaran80iFlowControlread-writecurrentThis object specifies if flow control is enabled or not.
1.3.6.1.4.1.10728.2.1.3.1.3.4Scalaran80iLowLatencyModeread-writecurrentThis object specifies if prioritized low latency mode is enabled or not.
1.3.6.1.4.1.10728.2.1.3.1.3.5Scalaran80iEthernetFollowsWirelessread-writecurrentThis object specifies if the Ethernet follows wireless mode is enabled or not.
1.3.6.1.4.1.10728.2.1.3.1.3.6Scalaran80iEthernetFollowsWirelessTimeoutread-writecurrentThis object specifies if the timeout (seconds) for the Ethernet follows wireless mode (0=infinite).
1.3.6.1.4.1.10728.2.1.3.1.4NoderedlineAn80iManagObjects
1.3.6.1.4.1.10728.2.1.3.1.4.1Scalaran80iHttpAccessread-writecurrentThis object specifies if Http Access is enabled or not.
1.3.6.1.4.1.10728.2.1.3.1.4.2Scalaran80iTelnetAccessread-writecurrentThis object specifies if Telnet Access is enabled or not.
1.3.6.1.4.1.10728.2.1.3.1.4.3Scalaran80iTelnetPortread-writecurrentThis object specifies the Telnet port number.
1.3.6.1.4.1.10728.2.1.3.1.5NoderedlineAn80iSWUpgradeObjects
1.3.6.1.4.1.10728.2.1.3.1.5.1Scalaran80iSwDownloadTftpAddressTyperead-writecurrentThe INET address type of the software upgrade TFTP server. IPv4 type supported only.
1.3.6.1.4.1.10728.2.1.3.1.5.2Scalaran80iSwDownloadTftpAddressread-writecurrentThe INET address of the TFTP server.
1.3.6.1.4.1.10728.2.1.3.1.5.3Scalaran80iSwDownloadTftpFileread-writecurrentThe image file name as required by the TFTP server.
1.3.6.1.4.1.10728.2.1.3.1.5.4Scalaran80iSwDownloadStatusread-onlycurrentThe status of the current software download.
1.3.6.1.4.1.10728.2.1.3.1.5.5Scalaran80iSwDownloadControlread-writecurrentTrigger software upgrade
1.3.6.1.4.1.10728.2.1.3.2NoderedlineAn80iPmpObjects
1.3.6.1.4.1.10728.2.1.3.2.1NoderedlineAn80iPmpWirelesObjects
1.3.6.1.4.1.10728.2.1.3.2.1.1Scalaran80iRegistrationPeriodread-writecurrentNumber of frames between two consecutive registration periods.
1.3.6.1.4.1.10728.2.1.3.2.1.2Scalaran80iMaximumDistanceread-writecurrentMaximum distance in km between the sector controller and one subscriber station.
1.3.6.1.4.1.10728.2.1.3.2.1.3Scalaran80iRegisteredStationsread-onlycurrentThe number of registered stations on the sector controller.
1.3.6.1.4.1.10728.2.1.3.2.1.4Scalaran80iRegisteredConnectionsread-onlycurrentThe number of registered connections on the sector controller.
1.3.6.1.4.1.10728.2.1.3.2.1.5Scalaran80iMaxIdread-onlycurrentThe maximum number of ID used to identify links, connections and groups
1.3.6.1.4.1.10728.2.1.3.2.1.6Scalaran80iNextAvailIdread-onlycurrentThe next available ID from the ID pool which is not grater then that defined in 'an80iMaxId'
1.3.6.1.4.1.10728.2.1.3.2.1.7Scalaran80iLastModifIdread-onlycurrentThe last modified ID from the ID pool which is not grater then that defined in 'an80iMaxId'
1.3.6.1.4.1.10728.2.1.3.2.1.8Scalaran80iSaveIdConfigurationread-writecurrentSave the ID table in the flash memory
1.3.6.1.4.1.10728.2.1.3.3NoderedlineAn80iPtpObjects
1.3.6.1.4.1.10728.2.1.3.3.1NoderedlineAn80iPtpSystemObjects
1.3.6.1.4.1.10728.2.1.3.3.1.1Scalaran80iResetStatisticsread-writecurrentThis object resets wireless and Ethernet counters
1.3.6.1.4.1.10728.2.1.3.5NoderedlineAn80iConformance
1.3.6.1.4.1.10728.2.1.3.5.1NoderedlineAn80iGroups
1.3.6.1.4.1.10728.2.1.3.5.1.1GroupredlineAn80iPtpPmpGroupcurrentAN80i PTP/PMP objects.
1.3.6.1.4.1.10728.2.1.3.5.1.2GroupredlineAn80iPmpGroupcurrentAN80i PMP objects.
1.3.6.1.4.1.10728.2.1.3.5.1.3GroupredlineAn80iPtpGroupcurrentAN80i PTP objects.
1.3.6.1.4.1.10728.2.1.3.5.1.4GroupredlineAn80iNotificationGroupcurrentThe notifications which indicate specific events within the AN80i unit.
1.3.6.1.4.1.10728.2.1.3.5.2NoderedlineAn80iCompls
1.3.6.1.4.1.10728.2.1.3.5.2.1ComplianceredlineAn80iCompliancecurrentThe compliance statement for AN80i entities that implement this MIB module.