MIB Viewer

REDLINE-BS-MIB

79 objects
This MIB module contains object definitions applicable only to Redline Base Station.
Imported Objects
INET-ADDRESS-MIBInetAddress InetAddressType InetPortNumber
REDLINE-MIBredlineSystem
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIInteger32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCDateAndTime DisplayString RowStatus
OIDNameAccessStatusDescription
1.3.6.1.4.1.10728.2.1.2IdentityredlineBsMibThis MIB module contains object definitions applicable only to Redline Base Station.
1.3.6.1.4.1.10728.2.1.2.1NoderedlineBsDhcpObjects
1.3.6.1.4.1.10728.2.1.2.1.1ScalarredlineBsIpAddressSourceread-writecurrentSetting this variable to 1 causes the Base Station to obatain its ip address from DHCP server.
1.3.6.1.4.1.10728.2.1.2.1.2ScalarredlineBsDhcpPacketsRelayread-writecurrentSetting this variable to 1 causes the Base Station to act as DHCP relay agent for SS. Note: This object can not be set to 'relay' if usage of DHCP server is di…
1.3.6.1.4.1.10728.2.1.2.2NoderedlineBsSntpObjects
1.3.6.1.4.1.10728.2.1.2.2.1ScalarredlineBsRefreshTimeread-writecurrentSetting this variable to 1 causes the Base Station to reconect to time server and synchronize the time
1.3.6.1.4.1.10728.2.1.2.2.2ScalarredlineBsDayLightSavingread-writecurrentThis variable indicates if Dalight saving is on.
1.3.6.1.4.1.10728.2.1.2.2.3ScalarredlineBsTimezoneread-writecurrentThis variable is a time zone set as +/- hours from Greenwich Mean Time (GMT). Note: This object can not be set if usage of DHCP server is enabled. An attempt t…
1.3.6.1.4.1.10728.2.1.2.2.4ScalarredlineBsTimeServerIpAddressTyperead-writecurrentThe INET address type of Ip address of time server. IPv4 type supported only.
1.3.6.1.4.1.10728.2.1.2.2.5ScalarredlineBsTimeServerIpAddressread-writecurrentThe INET address of time server to whom Bs will communicate using SNTP protocol to obtain the GMT time.
1.3.6.1.4.1.10728.2.1.2.2.6ScalarredlineBsTimezoneMinread-writecurrentThis variable contains a minutes part of time zone defined in 'redlineBsTimezone'. Note: This object can not be set if usage of DHCP server is enabled. An atte…
1.3.6.1.4.1.10728.2.1.2.3NoderedlineBsConfigSaveObjects
1.3.6.1.4.1.10728.2.1.2.3.1ScalarredlineBsSnmpConfigSaveread-writecurrentSetting this variable to 1 causes SNMP Configuration to be save in flash.
1.3.6.1.4.1.10728.2.1.2.3.2ScalarredlineBsSfConfigSaveread-writecurrentSetting this variable to 2 causes Service Flow Configuration to be saved in flash.
1.3.6.1.4.1.10728.2.1.2.4NoderedlineBsSystemObjects
1.3.6.1.4.1.10728.2.1.2.4.1ScalarredlineBsRadioTyperead-onlycurrentThis object indicates the radio type of Redline Bs.
1.3.6.1.4.1.10728.2.1.2.5NoderedlineBsRfObjects
1.3.6.1.4.1.10728.2.1.2.5.1ScalarredlineBsDownlinkChanFreqread-onlycurrentCurrent downlink channel frequency (kHz)
1.3.6.1.4.1.10728.2.1.2.5.2ScalarredlineBsUplinkChanFreqread-onlycurrentCurrent uplink channel frequency (kHz)
1.3.6.1.4.1.10728.2.1.2.6NoderedlineBsPhyObjects
1.3.6.1.4.1.10728.2.1.2.6.1ScalarredlineBsChannelSizeread-onlycurrentCurrent channel size (Khz).
1.3.6.1.4.1.10728.2.1.2.7NoderedlineBsEthObjects
1.3.6.1.4.1.10728.2.1.2.7.1ScalarredlineBsManagementAccessread-onlycurrentIndicates current management access configuration( either data or mgt port.
1.3.6.1.4.1.10728.2.1.2.7.2ScalarredlineBsDataPortSettingsread-onlycurrentIndicates current settings of data port.
1.3.6.1.4.1.10728.2.1.2.7.3ScalarredlineBsMgtPortSettingsread-onlycurrentIndicates current settings of mgt port.
1.3.6.1.4.1.10728.2.1.2.8NoderedlineBsVlanObjects
1.3.6.1.4.1.10728.2.1.2.8.1ScalarredlineBsVlanTrafficTaggingread-onlycurrentIndicates that management with VLAN tagged traffic is enabled.
1.3.6.1.4.1.10728.2.1.2.8.2ScalarredlineBsVlanIdread-onlycurrentVLAN identifier used to tag managment traffic.
1.3.6.1.4.1.10728.2.1.2.9NoderedlineBsSmcObjects
1.3.6.1.4.1.10728.2.1.2.9.1ScalarredlineBsSmcCurrentOperModeread-writecurrentIndicates BS SMC (Secondary Management Channel) operation window. At the beginning of a maintenance window (upgrade, config backup etc), the SMC will be assign…
1.3.6.1.4.1.10728.2.1.2.10NoderedlineBsPowerSupplyAndCoolingObjects
1.3.6.1.4.1.10728.2.1.2.10.1TableredlineBsPowerSupplyTablenot-accessiblecurrentThis table contains identification and status information about base station power supplies. A trap will be generated each time the power supply goes on or off…
1.3.6.1.4.1.10728.2.1.2.10.1.1RowredlineBsPowerSupplyEntrynot-accessiblecurrentThis entry contains status information about base station power supply.
1.3.6.1.4.1.10728.2.1.2.10.1.1.1ColumnredlineBsPowerSupplyIndexnot-accessiblecurrentThe index of the BS power supply table.
1.3.6.1.4.1.10728.2.1.2.10.1.1.2ColumnredlineBsPowerSupplyNameread-onlycurrentTextual identification of base station power supply.
1.3.6.1.4.1.10728.2.1.2.10.1.1.3ColumnredlineBsPowerSupplyTyperead-onlycurrentThe power supply type.
1.3.6.1.4.1.10728.2.1.2.10.1.1.4ColumnredlineBsPowerSupplyStatusread-onlycurrentIndicates if the power supply is on/off.
1.3.6.1.4.1.10728.2.1.2.10.2TableredlineBsTemperatureTablenot-accessiblecurrentThis table contains information about current temperature of base station hardware units.
1.3.6.1.4.1.10728.2.1.2.10.2.1RowredlineBsTemperatureEntrynot-accessiblecurrentThis entry contains temperature information about single base station hardware unit.
1.3.6.1.4.1.10728.2.1.2.10.2.1.1ColumnredlineBsUnitIndexnot-accessiblecurrentThe index of the BS current temperature table.
1.3.6.1.4.1.10728.2.1.2.10.2.1.2ColumnredlineBsUnitNameread-onlycurrentThe base station hardware unit name.
1.3.6.1.4.1.10728.2.1.2.10.2.1.3ColumnredlineBsUnitTyperead-onlycurrentThe base station hardware unit type.
1.3.6.1.4.1.10728.2.1.2.10.2.1.4ColumnredlineBsCurrTemperatureread-onlycurrentIndicates the current temperature of base station hardware unit in Celsius.
1.3.6.1.4.1.10728.2.1.2.10.3TableredlineBsTempThresholdTablenot-accessiblecurrentThis table contains various temperature threshold which are used to trigger traps to alarm network manager about unit mulfunction. The table is indexed by 'red…
1.3.6.1.4.1.10728.2.1.2.10.3.1RowredlineBsTempThresholdEntrynot-accessiblecurrentThis entry contains single base station hardware unit temperarure threshold information.
1.3.6.1.4.1.10728.2.1.2.10.3.1.1ColumnredlineBsTempThresholdIndexnot-accessiblecurrentThe index of the temperature threshold table.
1.3.6.1.4.1.10728.2.1.2.10.3.1.2ColumnredlineBsTempTrapThresholdread-onlycurrentIndicates the temperature threshold value which will be used to trigger a trap.
1.3.6.1.4.1.10728.2.1.2.10.3.1.3ColumnredlineBsTempTrapClrThresholdread-onlycurrentIndicates the temperature threshold value which will be used to clear a previosly generated trap.
1.3.6.1.4.1.10728.2.1.2.10.3.1.4ColumnredlineBsTempThresholdNameread-onlycurrentTextual identification of temperature threshold.
1.3.6.1.4.1.10728.2.1.2.10.3.1.5ColumnredlineBsTemperatureTrapTriggerread-onlycurrentIndicates if temperature traversal in upper or lower value direction is causing the trap.
1.3.6.1.4.1.10728.2.1.2.10.4TableredlineBsFanTablenot-accessiblecurrentThis table contains name and status information about base station cooling fans. Up to 3 entries are supported.
1.3.6.1.4.1.10728.2.1.2.10.4.1RowredlineBsFanEntrynot-accessiblecurrentThis entry contains information about single cooling fan.
1.3.6.1.4.1.10728.2.1.2.10.4.1.1ColumnredlineBsFanIndexnot-accessiblecurrentThe index of the colling fans table.
1.3.6.1.4.1.10728.2.1.2.10.4.1.2ColumnredlineBsFanNameread-onlycurrentTextual identification of base station fan.
1.3.6.1.4.1.10728.2.1.2.10.4.1.3ColumnredlineBsFanStatusread-onlycurrentIndicates the base station fan is on/off.
1.3.6.1.4.1.10728.2.1.2.11NoderedlineBsNotificationObjects
1.3.6.1.4.1.10728.2.1.2.11.0NoderedlineBsTrapDefinitions
1.3.6.1.4.1.10728.2.1.2.11.0.1NotificationredlineBsPowerSupplyStatusTrapcurrentEvent that reports base station power supply status change (on/off).
1.3.6.1.4.1.10728.2.1.2.11.0.2NotificationredlineBsTempThresholdTrapcurrentEvent that reports SW Upgrade progress and status changes.
1.3.6.1.4.1.10728.2.1.2.11.1NoderedlineBsTrapMibObjects
1.3.6.1.4.1.10728.2.1.2.11.1.1ScalarredlineBsTrapTypeaccessible-for-notifycurrentIndicates if the trap is for alarm condition or for its clearing.
1.3.6.1.4.1.10728.2.1.2.11.1.2ScalarredlineBsTrapPowerSupplyIndexaccessible-for-notifycurrentThe index in the table representing BS power supply triggering the trap.
1.3.6.1.4.1.10728.2.1.2.11.1.3ScalarredlineBsTrapUnitIndexaccessible-for-notifycurrentThe index of temperature table representing BS unit triggering the trap.
1.3.6.1.4.1.10728.2.1.2.11.1.4ScalarredlineBsTrapTempThresholdIndexaccessible-for-notifycurrentThe index of the temperature threshold table representing the temperature threshold which passing is triggering the trap.
1.3.6.1.4.1.10728.2.1.2.12NoderedlineBsConformance
1.3.6.1.4.1.10728.2.1.2.12.1NoderedlineBsGroups
1.3.6.1.4.1.10728.2.1.2.12.1.1GroupredlineBsDhcpGroupcurrentDhcp objects.
1.3.6.1.4.1.10728.2.1.2.12.1.2GroupredlineBsSntpGroupcurrentSntp objects.
1.3.6.1.4.1.10728.2.1.2.12.1.3GroupredlineBsConfigSaveGroupcurrentConfig save objects.
1.3.6.1.4.1.10728.2.1.2.12.1.4GroupredlineBsSystemGroupcurrentConfig save objects.
1.3.6.1.4.1.10728.2.1.2.12.1.5GroupredlineBsRfGroupcurrentConfig save objects.
1.3.6.1.4.1.10728.2.1.2.12.1.6GroupredlineBsPhyGroupcurrentConfig save objects.
1.3.6.1.4.1.10728.2.1.2.12.1.7GroupredlineBsEthGroupcurrentEthernet interface objects.
1.3.6.1.4.1.10728.2.1.2.12.1.8GroupredlineBsVlanGroupcurrentVlan objects.
1.3.6.1.4.1.10728.2.1.2.12.1.9GroupredlineBsSmcGroupcurrentSmc objects.
1.3.6.1.4.1.10728.2.1.2.12.1.10GroupredlineBsPowerSupplyAndCoolingGroupcurrentPower supply, temperature and fans objects.
1.3.6.1.4.1.10728.2.1.2.12.1.11GroupredlineBsNotificationGroupcurrent
1.3.6.1.4.1.10728.2.1.2.12.2NoderedlineBsCompls
1.3.6.1.4.1.10728.2.1.2.12.2.1ComplianceredlineBsCompliancecurrentThe compliance statement for SNMP entities that implement this MIB module.