REDLINE-BS-MIB
79 objects
This MIB module contains object definitions applicable only to Redline Base Station.
Imported Objects
| INET-ADDRESS-MIB | InetAddress InetAddressType InetPortNumber |
| REDLINE-MIB | redlineSystem |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DateAndTime DisplayString RowStatus |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.10728.2.1.2 | IdentityredlineBsMib | This MIB module contains object definitions applicable only to Redline Base Station. | ||
| 1.3.6.1.4.1.10728.2.1.2.1 | NoderedlineBsDhcpObjects | |||
| 1.3.6.1.4.1.10728.2.1.2.1.1 | ScalarredlineBsIpAddressSource | read-write | current | Setting this variable to 1 causes the Base Station to obatain its ip address from DHCP server. |
| 1.3.6.1.4.1.10728.2.1.2.1.2 | ScalarredlineBsDhcpPacketsRelay | read-write | current | Setting this variable to 1 causes the Base Station to act as DHCP relay agent for SS. Note: This object can not be set to 'relay' if usage of DHCP server is di… |
| 1.3.6.1.4.1.10728.2.1.2.2 | NoderedlineBsSntpObjects | |||
| 1.3.6.1.4.1.10728.2.1.2.2.1 | ScalarredlineBsRefreshTime | read-write | current | Setting this variable to 1 causes the Base Station to reconect to time server and synchronize the time |
| 1.3.6.1.4.1.10728.2.1.2.2.2 | ScalarredlineBsDayLightSaving | read-write | current | This variable indicates if Dalight saving is on. |
| 1.3.6.1.4.1.10728.2.1.2.2.3 | ScalarredlineBsTimezone | read-write | current | This variable is a time zone set as +/- hours from Greenwich Mean Time (GMT). Note: This object can not be set if usage of DHCP server is enabled. An attempt t… |
| 1.3.6.1.4.1.10728.2.1.2.2.4 | ScalarredlineBsTimeServerIpAddressType | read-write | current | The INET address type of Ip address of time server. IPv4 type supported only. |
| 1.3.6.1.4.1.10728.2.1.2.2.5 | ScalarredlineBsTimeServerIpAddress | read-write | current | The INET address of time server to whom Bs will communicate using SNTP protocol to obtain the GMT time. |
| 1.3.6.1.4.1.10728.2.1.2.2.6 | ScalarredlineBsTimezoneMin | read-write | current | This variable contains a minutes part of time zone defined in 'redlineBsTimezone'. Note: This object can not be set if usage of DHCP server is enabled. An atte… |
| 1.3.6.1.4.1.10728.2.1.2.3 | NoderedlineBsConfigSaveObjects | |||
| 1.3.6.1.4.1.10728.2.1.2.3.1 | ScalarredlineBsSnmpConfigSave | read-write | current | Setting this variable to 1 causes SNMP Configuration to be save in flash. |
| 1.3.6.1.4.1.10728.2.1.2.3.2 | ScalarredlineBsSfConfigSave | read-write | current | Setting this variable to 2 causes Service Flow Configuration to be saved in flash. |
| 1.3.6.1.4.1.10728.2.1.2.4 | NoderedlineBsSystemObjects | |||
| 1.3.6.1.4.1.10728.2.1.2.4.1 | ScalarredlineBsRadioType | read-only | current | This object indicates the radio type of Redline Bs. |
| 1.3.6.1.4.1.10728.2.1.2.5 | NoderedlineBsRfObjects | |||
| 1.3.6.1.4.1.10728.2.1.2.5.1 | ScalarredlineBsDownlinkChanFreq | read-only | current | Current downlink channel frequency (kHz) |
| 1.3.6.1.4.1.10728.2.1.2.5.2 | ScalarredlineBsUplinkChanFreq | read-only | current | Current uplink channel frequency (kHz) |
| 1.3.6.1.4.1.10728.2.1.2.6 | NoderedlineBsPhyObjects | |||
| 1.3.6.1.4.1.10728.2.1.2.6.1 | ScalarredlineBsChannelSize | read-only | current | Current channel size (Khz). |
| 1.3.6.1.4.1.10728.2.1.2.7 | NoderedlineBsEthObjects | |||
| 1.3.6.1.4.1.10728.2.1.2.7.1 | ScalarredlineBsManagementAccess | read-only | current | Indicates current management access configuration( either data or mgt port. |
| 1.3.6.1.4.1.10728.2.1.2.7.2 | ScalarredlineBsDataPortSettings | read-only | current | Indicates current settings of data port. |
| 1.3.6.1.4.1.10728.2.1.2.7.3 | ScalarredlineBsMgtPortSettings | read-only | current | Indicates current settings of mgt port. |
| 1.3.6.1.4.1.10728.2.1.2.8 | NoderedlineBsVlanObjects | |||
| 1.3.6.1.4.1.10728.2.1.2.8.1 | ScalarredlineBsVlanTrafficTagging | read-only | current | Indicates that management with VLAN tagged traffic is enabled. |
| 1.3.6.1.4.1.10728.2.1.2.8.2 | ScalarredlineBsVlanId | read-only | current | VLAN identifier used to tag managment traffic. |
| 1.3.6.1.4.1.10728.2.1.2.9 | NoderedlineBsSmcObjects | |||
| 1.3.6.1.4.1.10728.2.1.2.9.1 | ScalarredlineBsSmcCurrentOperMode | read-write | current | Indicates BS SMC (Secondary Management Channel) operation window. At the beginning of a maintenance window (upgrade, config backup etc), the SMC will be assign… |
| 1.3.6.1.4.1.10728.2.1.2.10 | NoderedlineBsPowerSupplyAndCoolingObjects | |||
| 1.3.6.1.4.1.10728.2.1.2.10.1 | TableredlineBsPowerSupplyTable | not-accessible | current | This table contains identification and status information about base station power supplies. A trap will be generated each time the power supply goes on or off… |
| 1.3.6.1.4.1.10728.2.1.2.10.1.1 | RowredlineBsPowerSupplyEntry | not-accessible | current | This entry contains status information about base station power supply. |
| 1.3.6.1.4.1.10728.2.1.2.10.1.1.1 | ColumnredlineBsPowerSupplyIndex | not-accessible | current | The index of the BS power supply table. |
| 1.3.6.1.4.1.10728.2.1.2.10.1.1.2 | ColumnredlineBsPowerSupplyName | read-only | current | Textual identification of base station power supply. |
| 1.3.6.1.4.1.10728.2.1.2.10.1.1.3 | ColumnredlineBsPowerSupplyType | read-only | current | The power supply type. |
| 1.3.6.1.4.1.10728.2.1.2.10.1.1.4 | ColumnredlineBsPowerSupplyStatus | read-only | current | Indicates if the power supply is on/off. |
| 1.3.6.1.4.1.10728.2.1.2.10.2 | TableredlineBsTemperatureTable | not-accessible | current | This table contains information about current temperature of base station hardware units. |
| 1.3.6.1.4.1.10728.2.1.2.10.2.1 | RowredlineBsTemperatureEntry | not-accessible | current | This entry contains temperature information about single base station hardware unit. |
| 1.3.6.1.4.1.10728.2.1.2.10.2.1.1 | ColumnredlineBsUnitIndex | not-accessible | current | The index of the BS current temperature table. |
| 1.3.6.1.4.1.10728.2.1.2.10.2.1.2 | ColumnredlineBsUnitName | read-only | current | The base station hardware unit name. |
| 1.3.6.1.4.1.10728.2.1.2.10.2.1.3 | ColumnredlineBsUnitType | read-only | current | The base station hardware unit type. |
| 1.3.6.1.4.1.10728.2.1.2.10.2.1.4 | ColumnredlineBsCurrTemperature | read-only | current | Indicates the current temperature of base station hardware unit in Celsius. |
| 1.3.6.1.4.1.10728.2.1.2.10.3 | TableredlineBsTempThresholdTable | not-accessible | current | This table contains various temperature threshold which are used to trigger traps to alarm network manager about unit mulfunction. The table is indexed by 'red… |
| 1.3.6.1.4.1.10728.2.1.2.10.3.1 | RowredlineBsTempThresholdEntry | not-accessible | current | This entry contains single base station hardware unit temperarure threshold information. |
| 1.3.6.1.4.1.10728.2.1.2.10.3.1.1 | ColumnredlineBsTempThresholdIndex | not-accessible | current | The index of the temperature threshold table. |
| 1.3.6.1.4.1.10728.2.1.2.10.3.1.2 | ColumnredlineBsTempTrapThreshold | read-only | current | Indicates the temperature threshold value which will be used to trigger a trap. |
| 1.3.6.1.4.1.10728.2.1.2.10.3.1.3 | ColumnredlineBsTempTrapClrThreshold | read-only | current | Indicates the temperature threshold value which will be used to clear a previosly generated trap. |
| 1.3.6.1.4.1.10728.2.1.2.10.3.1.4 | ColumnredlineBsTempThresholdName | read-only | current | Textual identification of temperature threshold. |
| 1.3.6.1.4.1.10728.2.1.2.10.3.1.5 | ColumnredlineBsTemperatureTrapTrigger | read-only | current | Indicates if temperature traversal in upper or lower value direction is causing the trap. |
| 1.3.6.1.4.1.10728.2.1.2.10.4 | TableredlineBsFanTable | not-accessible | current | This table contains name and status information about base station cooling fans. Up to 3 entries are supported. |
| 1.3.6.1.4.1.10728.2.1.2.10.4.1 | RowredlineBsFanEntry | not-accessible | current | This entry contains information about single cooling fan. |
| 1.3.6.1.4.1.10728.2.1.2.10.4.1.1 | ColumnredlineBsFanIndex | not-accessible | current | The index of the colling fans table. |
| 1.3.6.1.4.1.10728.2.1.2.10.4.1.2 | ColumnredlineBsFanName | read-only | current | Textual identification of base station fan. |
| 1.3.6.1.4.1.10728.2.1.2.10.4.1.3 | ColumnredlineBsFanStatus | read-only | current | Indicates the base station fan is on/off. |
| 1.3.6.1.4.1.10728.2.1.2.11 | NoderedlineBsNotificationObjects | |||
| 1.3.6.1.4.1.10728.2.1.2.11.0 | NoderedlineBsTrapDefinitions | |||
| 1.3.6.1.4.1.10728.2.1.2.11.0.1 | NotificationredlineBsPowerSupplyStatusTrap | current | Event that reports base station power supply status change (on/off). | |
| 1.3.6.1.4.1.10728.2.1.2.11.0.2 | NotificationredlineBsTempThresholdTrap | current | Event that reports SW Upgrade progress and status changes. | |
| 1.3.6.1.4.1.10728.2.1.2.11.1 | NoderedlineBsTrapMibObjects | |||
| 1.3.6.1.4.1.10728.2.1.2.11.1.1 | ScalarredlineBsTrapType | accessible-for-notify | current | Indicates if the trap is for alarm condition or for its clearing. |
| 1.3.6.1.4.1.10728.2.1.2.11.1.2 | ScalarredlineBsTrapPowerSupplyIndex | accessible-for-notify | current | The index in the table representing BS power supply triggering the trap. |
| 1.3.6.1.4.1.10728.2.1.2.11.1.3 | ScalarredlineBsTrapUnitIndex | accessible-for-notify | current | The index of temperature table representing BS unit triggering the trap. |
| 1.3.6.1.4.1.10728.2.1.2.11.1.4 | ScalarredlineBsTrapTempThresholdIndex | accessible-for-notify | current | The index of the temperature threshold table representing the temperature threshold which passing is triggering the trap. |
| 1.3.6.1.4.1.10728.2.1.2.12 | NoderedlineBsConformance | |||
| 1.3.6.1.4.1.10728.2.1.2.12.1 | NoderedlineBsGroups | |||
| 1.3.6.1.4.1.10728.2.1.2.12.1.1 | GroupredlineBsDhcpGroup | current | Dhcp objects. | |
| 1.3.6.1.4.1.10728.2.1.2.12.1.2 | GroupredlineBsSntpGroup | current | Sntp objects. | |
| 1.3.6.1.4.1.10728.2.1.2.12.1.3 | GroupredlineBsConfigSaveGroup | current | Config save objects. | |
| 1.3.6.1.4.1.10728.2.1.2.12.1.4 | GroupredlineBsSystemGroup | current | Config save objects. | |
| 1.3.6.1.4.1.10728.2.1.2.12.1.5 | GroupredlineBsRfGroup | current | Config save objects. | |
| 1.3.6.1.4.1.10728.2.1.2.12.1.6 | GroupredlineBsPhyGroup | current | Config save objects. | |
| 1.3.6.1.4.1.10728.2.1.2.12.1.7 | GroupredlineBsEthGroup | current | Ethernet interface objects. | |
| 1.3.6.1.4.1.10728.2.1.2.12.1.8 | GroupredlineBsVlanGroup | current | Vlan objects. | |
| 1.3.6.1.4.1.10728.2.1.2.12.1.9 | GroupredlineBsSmcGroup | current | Smc objects. | |
| 1.3.6.1.4.1.10728.2.1.2.12.1.10 | GroupredlineBsPowerSupplyAndCoolingGroup | current | Power supply, temperature and fans objects. | |
| 1.3.6.1.4.1.10728.2.1.2.12.1.11 | GroupredlineBsNotificationGroup | current | ||
| 1.3.6.1.4.1.10728.2.1.2.12.2 | NoderedlineBsCompls | |||
| 1.3.6.1.4.1.10728.2.1.2.12.2.1 | ComplianceredlineBsCompliance | current | The compliance statement for SNMP entities that implement this MIB module. |