RFC1230-MIB
58 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC1155-SMI | experimental |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.3.7 | Nodedot4 | |||
| 1.3.6.1.3.7.1 | Tabledot4Table | not-accessible | mandatory | This table contains Token Bus interface parameters and state variables, one entry per 802.5 interface. |
| 1.3.6.1.3.7.1.1 | Rowdot4Entry | not-accessible | mandatory | A list of Token Bus status and operational parameter values for an 802.4 interface. |
| 1.3.6.1.3.7.1.1.1 | Columndot4IfIndex | read-only | mandatory | The value of this object identifies the 802.4 interface for which this entry contains management information. The value of this object for a particular interfa… |
| 1.3.6.1.3.7.1.1.2 | Columndot4Options | read-only | mandatory | The optional parts of the 802.4 specification which are in use by this station. The options of the 802.4 specification are represented by the following values:… |
| 1.3.6.1.3.7.1.1.3 | Columndot4State | read-only | mandatory | The current state of the 802.4 interface. The value of other(1) is used if the state is unknown (e.g., due to an error condition). |
| 1.3.6.1.3.7.1.1.4 | Columndot4Commands | read-write | mandatory | Setting this object causes the station to change the state of the interface as indicated by the specified value. An initialize(5) command causes the interfacet… |
| 1.3.6.1.3.7.1.1.5 | Columndot4MacAddrLen | read-only | mandatory | This object indicates the size of MAC addresses interpreted by this station. |
| 1.3.6.1.3.7.1.1.6 | Columndot4NextStation | read-only | mandatory | The MAC address of this station's successor in the logical ring. |
| 1.3.6.1.3.7.1.1.7 | Columndot4PreviousStation | read-only | mandatory | The source MAC address of the last token addressed to this station. |
| 1.3.6.1.3.7.1.1.8 | Columndot4SlotTime | read-only | mandatory | The maximum time any station need wait for an immediate MAC-level response from another station. This value must the same in all stations on the 802.4 network. |
| 1.3.6.1.3.7.1.1.9 | Columndot4LastTokenRotTime | read-only | mandatory | The observed token rotation time for the last token rotation, timed from token arrival to token arrival. A value of zero indicates that the token is not rotati… |
| 1.3.6.1.3.7.1.1.10 | Columndot4HiPriTokenHoldTime | read-only | mandatory | The maximum duration for which a station can hold the token to transmit frames of access class 6 (if the priority option is implemented), or of any access clas… |
| 1.3.6.1.3.7.1.1.11 | Columndot4TargetRotTimeClass4 | read-only | mandatory | If the priority scheme is being used, this value specifies a limit on how long a station can transmit frames at access class 4. The limit is measured from the … |
| 1.3.6.1.3.7.1.1.12 | Columndot4TargetRotTimeClass2 | read-only | mandatory | If the priority scheme is being used, this value specifies a limit on how long a station can transmit frames at access class 2. The limit is measured from the … |
| 1.3.6.1.3.7.1.1.13 | Columndot4TargetRotTimeClass0 | read-only | mandatory | If the priority scheme is being used, this value specifies a limit on how long a station can transmit frames at access class 0. The limit is measured from the … |
| 1.3.6.1.3.7.1.1.14 | Columndot4TargetRotTimeRingMaint | read-only | mandatory | A value used to limit the duration of a token rotation. If the duration of a token rotation exceeds this value, the station will not open the response window t… |
| 1.3.6.1.3.7.1.1.15 | Columndot4RingMaintTimerInitValue | read-only | mandatory | The value to which the dot4TargetRotTimeRingMaint is set, each time the station enters the ring. A large value will cause the station to solicit successors imm… |
| 1.3.6.1.3.7.1.1.16 | Columndot4MaxInterSolicitCount | read-only | mandatory | The maximum number of consecutive token rotations without soliciting for a successor. If this count expires, the station opens the response window to solicit f… |
| 1.3.6.1.3.7.1.1.17 | Columndot4MaxRetries | read-only | mandatory | The maximum number of retries of a Request-with-Response (RWR) frame. If the RWR option is not in use, this object has the value 0. |
| 1.3.6.1.3.7.1.1.18 | Columndot4MinPostSilencePreambLen | read-only | mandatory | The minimum number of octets of preamble on the first frame transmitted by this station after a period of 'transmitted' silence. |
| 1.3.6.1.3.7.1.1.19 | Columndot4StandardRevision | read-only | mandatory | The Revision number of the 802.4 standard implemented by this station. |
| 1.3.6.1.3.7.2 | Tabledot4InitTable | not-accessible | mandatory | This table contains Token Bus initialization parameters, one entry per 802.4 interface. |
| 1.3.6.1.3.7.2.1 | Rowdot4InitEntry | not-accessible | mandatory | A list of Token Bus initialization parameters for an 802.4 interface. |
| 1.3.6.1.3.7.2.1.1 | Columndot4InitIfIndex | read-only | mandatory | The value of this object identifies the 802.4 interface for which this entry contains management information. The value of this object for a particular interfa… |
| 1.3.6.1.3.7.2.1.2 | Columndot4InitSlotTime | read-write | mandatory | The value assigned to the object dot4SlotTime when the station is initialized. |
| 1.3.6.1.3.7.2.1.3 | Columndot4InitMaxInterSolicitCount | read-write | mandatory | The value assigned to the object dot4MaxInterSolicitCount when the station is initialized. |
| 1.3.6.1.3.7.2.1.4 | Columndot4InitMaxRetries | read-write | mandatory | The value assigned to the object dot4MaxRetries when the station is initialized. |
| 1.3.6.1.3.7.2.1.5 | Columndot4InitHiPriTokenHoldTime | read-write | mandatory | The value assigned to the object dot4HiPriTokenHoldTime when the station is initialized. |
| 1.3.6.1.3.7.2.1.6 | Columndot4InitTargetRotTimeClass4 | read-write | mandatory | The value assigned to the object dot4TargetRotTimeClass4 when the station is initialized. |
| 1.3.6.1.3.7.2.1.7 | Columndot4InitTargetRotTimeClass2 | read-write | mandatory | The value assigned to the object dot4TargetRotTimeClass2 when the station is initialized. |
| 1.3.6.1.3.7.2.1.8 | Columndot4InitTargetRotTimeClass0 | read-write | mandatory | The value assigned to the object dot4TargetRotTimeClass0 when the station is initialized. |
| 1.3.6.1.3.7.2.1.9 | Columndot4InitTargetRotTimeRingMaint | read-write | mandatory | The value assigned to the object dot4TargetRotTimeRingMaint when the station is initialized. |
| 1.3.6.1.3.7.2.1.10 | Columndot4InitRingMaintTimerInitValue | read-write | mandatory | The value assigned to the object dot4RingMaintTimerInitValue when the station is initialized. |
| 1.3.6.1.3.7.2.1.11 | Columndot4InitMinPostSilencePreambLen | read-write | mandatory | The value assigned to the object dot4MinPostSilencePreambLen when the station is initialized. |
| 1.3.6.1.3.7.2.1.12 | Columndot4InitInRingDesired | read-write | mandatory | This object determines whether the station will attempt to enter the logical ring immediately after initialization. |
| 1.3.6.1.3.7.3 | Tabledot4StatsTable | not-accessible | mandatory | A table containing Token Bus statistics. All the statistics are defined using the syntax Counter as 32 bit wrap around counters. Thus, if an interface's hardwa… |
| 1.3.6.1.3.7.3.1 | Rowdot4StatsEntry | not-accessible | mandatory | An entry containing the 802.4 statistics for a particular interface. |
| 1.3.6.1.3.7.3.1.1 | Columndot4StatsIfIndex | read-only | mandatory | The value of this object identifies the 802.4 interface for which this entry contains management information. The value of this object for a particular interfa… |
| 1.3.6.1.3.7.3.1.2 | Columndot4StatsTokenPasses | read-only | optional | The number of times this station has passed the token. |
| 1.3.6.1.3.7.3.1.3 | Columndot4StatsTokenHeards | read-only | optional | The number of tokens heard by this station. |
| 1.3.6.1.3.7.3.1.4 | Columndot4StatsNoSuccessors | read-only | mandatory | The number of times the station could not find a successor while believing itself not the only station in the ring. This can signify a faulty transmitter condi… |
| 1.3.6.1.3.7.3.1.5 | Columndot4StatsWhoFollows | read-only | mandatory | The number of times the station has had to look for a new next station. |
| 1.3.6.1.3.7.3.1.6 | Columndot4StatsTokenPassFails | read-only | mandatory | The number of times the station failed in passing the token to the next station. |
| 1.3.6.1.3.7.3.1.7 | Columndot4StatsNonSilences | read-only | mandatory | The number of occurrences of non-silence followed by silence in which a start delimiter was not detected. |
| 1.3.6.1.3.7.3.1.8 | Columndot4StatsFcsErrors | read-only | mandatory | The number of frames received with an incorrect FCS and the E-bit reset. |
| 1.3.6.1.3.7.3.1.9 | Columndot4StatsEbitErrors | read-only | mandatory | The number of frames the station received with the E-bit set in the end delimiter. |
| 1.3.6.1.3.7.3.1.10 | Columndot4StatsFrameFrags | read-only | mandatory | The number of occurrences of receiving a start delimiter followed by another start delimiter, an invalid symbol sequence or silence, without an intervening end… |
| 1.3.6.1.3.7.3.1.11 | Columndot4StatsFrameTooLongs | read-only | mandatory | The number of frames that were received that were larger than the media's MTU. |
| 1.3.6.1.3.7.3.1.12 | Columndot4StatsOverRuns | read-only | mandatory | The number of times a FIFO overrun was detected in the station. |
| 1.3.6.1.3.7.3.1.13 | Columndot4StatsDupAddresses | read-only | mandatory | The number of times this station detected another station using the same MAC address. |
| 1.3.6.1.3.7.4 | Nodedot4Errors | |||
| 1.3.6.1.3.7.4.1 | Nodedot4ModemInitFailed | |||
| 1.3.6.1.3.7.5 | Nodedot4Tests | |||
| 1.3.6.1.3.7.5.1 | NodetestFifoPath | |||
| 1.3.6.1.3.7.5.2 | NodetestExternalLoopback | |||
| 1.3.6.1.3.7.6 | Nodedot4ChipSets | |||
| 1.3.6.1.3.7.6.1 | NodechipSetMc68824 |