MIB Viewer

RFC1231-MIB

53 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.2.1.10.9Nodedot5
1.3.6.1.2.1.10.9.1Tabledot5Tablenot-accessiblemandatoryThis table contains Token Ring interface parameters and state variables, one entry per 802.5 interface.
1.3.6.1.2.1.10.9.1.1Rowdot5Entrynot-accessiblemandatoryA list of Token Ring status and parameter values for an 802.5 interface.
1.3.6.1.2.1.10.9.1.1.1Columndot5IfIndexread-onlymandatoryThe value of this object identifies the 802.5 interface for which this entry contains management information. The value of this object for a particular interfa…
1.3.6.1.2.1.10.9.1.1.2Columndot5Commandsread-writemandatoryWhen this object is set to the value of open(2), the station should go into the open state. The progress and success of the open is given by the values of the …
1.3.6.1.2.1.10.9.1.1.3Columndot5RingStatusread-onlymandatoryThe current interface status which can be used to diagnose fluctuating problems that can occur on token rings, after a station has successfully been added to t…
1.3.6.1.2.1.10.9.1.1.4Columndot5RingStateread-onlymandatoryThe current interface state with respect to entering or leaving the ring.
1.3.6.1.2.1.10.9.1.1.5Columndot5RingOpenStatusread-onlymandatoryThis object indicates the success, or the reason for failure, of the station's most recent attempt to enter the ring.
1.3.6.1.2.1.10.9.1.1.6Columndot5RingSpeedread-writemandatoryThe ring's bandwidth.
1.3.6.1.2.1.10.9.1.1.7Columndot5UpStreamread-onlymandatoryThe MAC-address of the up stream neighbor station in the ring.
1.3.6.1.2.1.10.9.1.1.8Columndot5ActMonParticipateread-writemandatoryIf this object has a value of true(1) then this interface will participate in the active monitor selection process. If the value is false(2) then it will not. …
1.3.6.1.2.1.10.9.1.1.9Columndot5Functionalread-writemandatoryThe bit mask of all Token Ring functional addresses for which this interface will accept frames.
1.3.6.1.2.1.10.9.2Tabledot5StatsTablenot-accessiblemandatoryA table containing Token Ring statistics, one entry per 802.5 interface. All the statistics are defined using the syntax Counter as 32-bit wrap around counters…
1.3.6.1.2.1.10.9.2.1Rowdot5StatsEntrynot-accessiblemandatoryAn entry contains the 802.5 statistics for a particular interface.
1.3.6.1.2.1.10.9.2.1.1Columndot5StatsIfIndexread-onlymandatoryThe value of this object identifies the 802.5 interface for which this entry contains management information. The value of this object for a particular interfa…
1.3.6.1.2.1.10.9.2.1.2Columndot5StatsLineErrorsread-onlymandatoryThis counter is incremented when a frame or token is copied or repeated by a station, the E bit is zero in the frame or token and one of the following conditio…
1.3.6.1.2.1.10.9.2.1.3Columndot5StatsBurstErrorsread-onlymandatoryThis counter is incremented when a station detects the absence of transitions for five half-bit timers (burst-five error).
1.3.6.1.2.1.10.9.2.1.4Columndot5StatsACErrorsread-onlymandatoryThis counter is incremented when a station receives an AMP or SMP frame in which A is equal to C is equal to 0, and then receives another SMP frame with A is e…
1.3.6.1.2.1.10.9.2.1.5Columndot5StatsAbortTransErrorsread-onlymandatoryThis counter is incremented when a station transmits an abort delimiter while transmitting.
1.3.6.1.2.1.10.9.2.1.6Columndot5StatsInternalErrorsread-onlymandatoryThis counter is incremented when a station recognizes an internal error.
1.3.6.1.2.1.10.9.2.1.7Columndot5StatsLostFrameErrorsread-onlymandatoryThis counter is incremented when a station is transmitting and its TRR timer expires. This condition denotes a condition where a transmitting station in strip …
1.3.6.1.2.1.10.9.2.1.8Columndot5StatsReceiveCongestionsread-onlymandatoryThis counter is incremented when a station recognizes a frame addressed to its specific address, but has no available buffer space indicating that the station …
1.3.6.1.2.1.10.9.2.1.9Columndot5StatsFrameCopiedErrorsread-onlymandatoryThis counter is incremented when a station recognizes a frame addressed to its specific address and detects that the FS field A bits are set to 1 indicating a …
1.3.6.1.2.1.10.9.2.1.10Columndot5StatsTokenErrorsread-onlymandatoryThis counter is incremented when a station acting as the active monitor recognizes an error condition that needs a token transmitted.
1.3.6.1.2.1.10.9.2.1.11Columndot5StatsSoftErrorsread-onlymandatoryThe number of Soft Errors the interface has detected. It directly corresponds to the number of Report Error MAC frames that this interface has transmitted. Sof…
1.3.6.1.2.1.10.9.2.1.12Columndot5StatsHardErrorsread-onlymandatoryThe number of times this interface has detected an immediately recoverable fatal error. It denotes the number of times this interface is either transmitting or…
1.3.6.1.2.1.10.9.2.1.13Columndot5StatsSignalLossread-onlymandatoryThe number of times this interface has detected the loss of signal condition from the ring.
1.3.6.1.2.1.10.9.2.1.14Columndot5StatsTransmitBeaconsread-onlymandatoryThe number of times this interface has transmitted a beacon frame.
1.3.6.1.2.1.10.9.2.1.15Columndot5StatsRecoverysread-onlymandatoryThe number of Claim Token MAC frames received or transmitted after the interface has received a Ring Purge MAC frame. This counter signifies the number of time…
1.3.6.1.2.1.10.9.2.1.16Columndot5StatsLobeWiresread-onlymandatoryThe number of times the interface has detected an open or short circuit in the lobe data path. The adapter will be closed and dot5RingState will signify this c…
1.3.6.1.2.1.10.9.2.1.17Columndot5StatsRemovesread-onlymandatoryThe number of times the interface has received a Remove Ring Station MAC frame request. When this frame is received the interface will enter the close state an…
1.3.6.1.2.1.10.9.2.1.18Columndot5StatsSinglesread-onlymandatoryThe number of times the interface has sensed that it is the only station on the ring. This will happen if the interface is the first one up on a ring, or if th…
1.3.6.1.2.1.10.9.2.1.19Columndot5StatsFreqErrorsread-onlyoptionalThe number of times the interface has detected that the frequency of the incoming signal differs from the expected frequency by more than that specified by the…
1.3.6.1.2.1.10.9.3Nodedot5Tests
1.3.6.1.2.1.10.9.3.1NodetestInsertFunc
1.3.6.1.2.1.10.9.4Nodedot5ChipSets
1.3.6.1.2.1.10.9.4.1NodechipSetIBM16
1.3.6.1.2.1.10.9.4.2NodechipSetTItms380
1.3.6.1.2.1.10.9.4.3NodechipSetTItms380c16
1.3.6.1.2.1.10.9.5Tabledot5TimerTablenot-accessiblemandatoryThis table contains Token Ring interface timer values, one entry per 802.5 interface.
1.3.6.1.2.1.10.9.5.1Rowdot5TimerEntrynot-accessiblemandatoryA list of Token Ring timer values for an 802.5 interface.
1.3.6.1.2.1.10.9.5.1.1Columndot5TimerIfIndexread-onlymandatoryThe value of this object identifies the 802.5 interface for which this entry contains timer values. The value of this object for a particular interface has the…
1.3.6.1.2.1.10.9.5.1.2Columndot5TimerReturnRepeatread-onlymandatoryThe time-out value used to ensure the interface will return to Repeat State, in units of 100 micro-seconds. The value should be greater than the maximum ring l…
1.3.6.1.2.1.10.9.5.1.3Columndot5TimerHoldingread-onlymandatoryMaximum period of time a station is permitted to transmit frames after capturing a token, in units of 100 micro-seconds. Implementors are encouraged to provide…
1.3.6.1.2.1.10.9.5.1.4Columndot5TimerQueuePDUread-onlymandatoryThe time-out value for enqueuing of an SMP PDU after reception of an AMP or SMP frame in which the A and C bits were equal to 0, in units of 100 micro-seconds.…
1.3.6.1.2.1.10.9.5.1.5Columndot5TimerValidTransmitread-onlymandatoryThe time-out value used by the active monitor to detect the absence of valid transmissions, in units of 100 micro-seconds. Implementors are encouraged to provi…
1.3.6.1.2.1.10.9.5.1.6Columndot5TimerNoTokenread-onlymandatoryThe time-out value used to recover from various-related error situations [9]. If N is the maximum number of stations on the ring, the value of this timer is no…
1.3.6.1.2.1.10.9.5.1.7Columndot5TimerActiveMonread-onlymandatoryThe time-out value used by the active monitor to stimulate the enqueuing of an AMP PDU for transmission, in units of 100 micro-seconds. Implementors are encour…
1.3.6.1.2.1.10.9.5.1.8Columndot5TimerStandbyMonread-onlymandatoryThe time-out value used by the stand-by monitors to ensure that there is an active monitor on the ring and to detect a continuous stream of tokens, in units of…
1.3.6.1.2.1.10.9.5.1.9Columndot5TimerErrorReportread-onlymandatoryThe time-out value which determines how often a station shall send a Report Error MAC frame to report its error counters, in units of 100 micro-seconds. Implem…
1.3.6.1.2.1.10.9.5.1.10Columndot5TimerBeaconTransmitread-onlymandatoryThe time-out value which determines how long a station shall remain in the state of transmitting Beacon frames before entering the Bypass state, in units of 10…
1.3.6.1.2.1.10.9.5.1.11Columndot5TimerBeaconReceiveread-onlymandatoryThe time-out value which determines how long a station shall receive Beacon frames from its downstream neighbor before entering the Bypass state, in units of 1…
Type Definitions
NameSyntaxStatusDescription
MacAddressOCTET STRING (SIZE (6))