MIB Viewer

RIELLOUPS-MIB

165 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212OBJECT-TYPE
RFC-1215TRAP-TYPE
RFC1155-SMICounter Gauge
RIELLO-MIBrielloMIB
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMICounter32 Gauge32 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-IDENTITY
SNMPv2-TCAutonomousType DisplayString TestAndIncr TEXTUAL-CONVENTION TimeInterval TimeStamp
OIDNameAccessStatusDescription
1.3.6.1.4.1.5491.10NoderupsMIB
1.3.6.1.4.1.5491.10.1NoderupsObjects
1.3.6.1.4.1.5491.10.1.1NoderupsIdent
1.3.6.1.4.1.5491.10.1.1.1ScalarrupsIdentManufacturerread-onlymandatoryThe name of the UPS manufacturer.
1.3.6.1.4.1.5491.10.1.1.2ScalarrupsIdentModelread-onlymandatoryThe UPS Model designation.
1.3.6.1.4.1.5491.10.1.1.3ScalarrupsIdentUPSSoftwareVersionread-onlymandatoryThe UPS firmware/software version(s). This variable may or may not have the same value as upsIdentAgentSoftwareVersion in some implementations.
1.3.6.1.4.1.5491.10.1.1.4ScalarrupsIdentAgentSoftwareVersionread-onlymandatoryThe UPS agent software version. This variable may or may not have the same value as upsIdentUPSSoftwareVersion in some implementations.
1.3.6.1.4.1.5491.10.1.1.5ScalarrupsIdentNameread-writemandatoryA string identifying the UPS. This object should be set by the administrator.
1.3.6.1.4.1.5491.10.1.1.6ScalarrupsIdentAttachedDevicesread-writemandatoryA string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator.
1.3.6.1.4.1.5491.10.1.1.7ScalarrupsIdentIOConfigurationread-onlymandatoryThe UPS IO configuration.
1.3.6.1.4.1.5491.10.1.1.8ScalarrupsIdentUpsTyperead-onlymandatoryThe UPS type.
1.3.6.1.4.1.5491.10.1.1.9ScalarrupsIdentNominalPowerVAread-onlymandatoryThe UPS nominal power VA.
1.3.6.1.4.1.5491.10.1.1.10ScalarrupsIdentNominalPowerWread-onlymandatoryThe UPS nominal power W.
1.3.6.1.4.1.5491.10.1.1.11ScalarrupsIdentBatteryVoltageread-onlymandatoryThe UPS nominal battery voltage.
1.3.6.1.4.1.5491.10.1.1.12ScalarrupsIdentBatteryCapacityread-onlymandatoryThe UPS nominal battery capacity.
1.3.6.1.4.1.5491.10.1.1.13ScalarrupsIdentOutputVoltageread-onlymandatoryThe UPS nominal output voltage.
1.3.6.1.4.1.5491.10.1.1.14ScalarrupsIdentOutputFrequencyread-onlymandatoryThe UPS nominal output frequency.
1.3.6.1.4.1.5491.10.1.2NoderupsBattery
1.3.6.1.4.1.5491.10.1.2.1ScalarrupsBatteryStatusread-onlymandatoryThe indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than rupsConf…
1.3.6.1.4.1.5491.10.1.2.2ScalarrupsSecondsOnBatteryread-onlymandatoryIf the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last res…
1.3.6.1.4.1.5491.10.1.2.3ScalarrupsEstimatedMinutesRemainingread-onlymandatoryAn estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and…
1.3.6.1.4.1.5491.10.1.2.4ScalarrupsEstimatedChargeRemainingread-onlymandatoryAn estimate of the battery charge remaining expressed as a percent of full charge.
1.3.6.1.4.1.5491.10.1.2.5ScalarrupsBatteryVoltageread-onlymandatoryThe magnitude of the present battery voltage.
1.3.6.1.4.1.5491.10.1.2.6ScalarrupsBatteryCurrentread-onlymandatoryThe present battery current.
1.3.6.1.4.1.5491.10.1.2.7ScalarrupsBatteryTemperatureread-onlymandatoryThe ambient temperature at or near the UPS Battery casing.
1.3.6.1.4.1.5491.10.1.2.8ScalarrupsBatteryPositiveVoltageread-onlymandatoryThe UPS Battery positive voltage.
1.3.6.1.4.1.5491.10.1.2.9ScalarrupsBatteryNegativeVoltageread-onlymandatoryThe UPS Battery negative voltage.
1.3.6.1.4.1.5491.10.1.2.10ScalarrupsBatteryPositiveCurrentread-onlymandatoryThe UPS Battery positive current.
1.3.6.1.4.1.5491.10.1.2.11ScalarrupsBatteryNegativeCurrentread-onlymandatoryThe UPS Battery positive current.
1.3.6.1.4.1.5491.10.1.2.12ScalarrupsIsChargingread-onlymandatoryThe charging/discharging status of the battery
1.3.6.1.4.1.5491.10.1.3NoderupsInput
1.3.6.1.4.1.5491.10.1.3.1ScalarrupsInputLineBadsread-onlymandatoryA count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the i…
1.3.6.1.4.1.5491.10.1.3.2ScalarrupsInputNumLinesread-onlymandatoryThe number of input lines utilized in this device. This variable indicates the number of rows in the input table.
1.3.6.1.4.1.5491.10.1.3.3TablerupsInputTablenot-accessiblemandatoryA list of input table entries. The number of entries is given by the value of upsInputNumLines.
1.3.6.1.4.1.5491.10.1.3.3.1RowrupsInputEntrynot-accessiblemandatoryAn entry containing information applicable to a particular input line.
1.3.6.1.4.1.5491.10.1.3.3.1.1ColumnrupsInputLineIndexnot-accessiblemandatoryThe input line identifier.
1.3.6.1.4.1.5491.10.1.3.3.1.2ColumnrupsInputFrequencyread-onlymandatoryThe present input frequency.
1.3.6.1.4.1.5491.10.1.3.3.1.3ColumnrupsInputVoltageread-onlymandatoryThe magnitude of the present input voltage.
1.3.6.1.4.1.5491.10.1.3.3.1.4ColumnrupsInputCurrentread-onlymandatoryThe magnitude of the present input current.
1.3.6.1.4.1.5491.10.1.3.3.1.5ColumnrupsInputTruePowerread-onlymandatoryThe magnitude of the present input true power.
1.3.6.1.4.1.5491.10.1.4NoderupsOutput
1.3.6.1.4.1.5491.10.1.4.1ScalarrupsOutputSourceread-onlymandatoryThe present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the…
1.3.6.1.4.1.5491.10.1.4.2ScalarrupsOutputFrequencyread-onlymandatoryThe present output frequency.
1.3.6.1.4.1.5491.10.1.4.3ScalarrupsOutputNumLinesread-onlymandatoryThe number of output lines utilized in this device. This variable indicates the number of rows in the output table.
1.3.6.1.4.1.5491.10.1.4.4TablerupsOutputTablenot-accessiblemandatoryA list of output table entries. The number of entries is given by the value of rupsOutputNumLines.
1.3.6.1.4.1.5491.10.1.4.4.1RowrupsOutputEntrynot-accessiblemandatoryAn entry containing information applicable to a particular output line.
1.3.6.1.4.1.5491.10.1.4.4.1.1ColumnrupsOutputLineIndexnot-accessiblemandatoryThe output line identifier.
1.3.6.1.4.1.5491.10.1.4.4.1.2ColumnrupsOutputVoltageread-onlymandatoryThe present output voltage.
1.3.6.1.4.1.5491.10.1.4.4.1.3ColumnrupsOutputCurrentread-onlymandatoryThe present output current.
1.3.6.1.4.1.5491.10.1.4.4.1.4ColumnrupsOutputPowerread-onlymandatoryThe present output true power.
1.3.6.1.4.1.5491.10.1.4.4.1.5ColumnrupsOutputPercentLoadread-onlymandatoryThe percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent…
1.3.6.1.4.1.5491.10.1.4.4.1.6ColumnrupsOutputPeakCurrentread-onlymandatoryThe present output peak current.
1.3.6.1.4.1.5491.10.1.5NoderupsBypass
1.3.6.1.4.1.5491.10.1.5.1ScalarrupsBypassFrequencyread-onlymandatoryThe present bypass frequency.
1.3.6.1.4.1.5491.10.1.5.2ScalarrupsBypassNumLinesread-onlymandatoryThe number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table.
1.3.6.1.4.1.5491.10.1.5.3TablerupsBypassTablenot-accessiblemandatoryA list of bypass table entries. The number of entries is given by the value of rupsBypassNumLines.
1.3.6.1.4.1.5491.10.1.5.3.1RowrupsBypassEntrynot-accessiblemandatoryAn entry containing information applicable to a particular bypass input.
1.3.6.1.4.1.5491.10.1.5.3.1.1ColumnrupsBypassLineIndexnot-accessiblemandatoryThe bypass line identifier.
1.3.6.1.4.1.5491.10.1.5.3.1.2ColumnrupsBypassVoltageread-onlymandatoryThe present bypass voltage.
1.3.6.1.4.1.5491.10.1.5.3.1.3ColumnrupsBypassCurrentread-onlymandatoryThe present bypass current.
1.3.6.1.4.1.5491.10.1.5.3.1.4ColumnrupsBypassPowerread-onlymandatoryThe present true power conveyed by the bypass.
1.3.6.1.4.1.5491.10.1.6NoderupsAlarm
1.3.6.1.4.1.5491.10.1.6.1ScalarrupsAlarmsPresentread-onlymandatoryThe present number of active alarm conditions.
1.3.6.1.4.1.5491.10.1.6.2TablerupsAlarmTablenot-accessiblemandatoryA list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is …
1.3.6.1.4.1.5491.10.1.6.2.1RowrupsAlarmEntrynot-accessiblemandatoryAn entry containing information applicable to a particular alarm.
1.3.6.1.4.1.5491.10.1.6.2.1.1ColumnrupsAlarmIdnot-accessiblemandatoryA unique identifier for an alarm condition. This value must remain constant.
1.3.6.1.4.1.5491.10.1.6.2.1.2ColumnrupsAlarmDescrread-onlymandatoryA reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm con…
1.3.6.1.4.1.5491.10.1.6.2.1.3ColumnrupsAlarmTimeread-onlymandatoryThe value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before ag…
1.3.6.1.4.1.5491.10.1.6.3NoderupsWellKnownAlarms
1.3.6.1.4.1.5491.10.1.6.3.1NoderupsAlarmBatteryBad
1.3.6.1.4.1.5491.10.1.6.3.2NoderupsAlarmOnBattery
1.3.6.1.4.1.5491.10.1.6.3.3NoderupsAlarmLowBattery
1.3.6.1.4.1.5491.10.1.6.3.4NoderupsAlarmShutdownImminent
1.3.6.1.4.1.5491.10.1.6.3.5NoderupsAlarmTempBad
1.3.6.1.4.1.5491.10.1.6.3.6NoderupsAlarmFault
1.3.6.1.4.1.5491.10.1.6.3.7NoderupsAlarmInternal
1.3.6.1.4.1.5491.10.1.6.3.8NoderupsAlarmOutputOverload
1.3.6.1.4.1.5491.10.1.6.3.9NoderupsAlarmOnBypass
1.3.6.1.4.1.5491.10.1.6.3.10NoderupsAlarmBypassBad
1.3.6.1.4.1.5491.10.1.7NoderupsTest
1.3.6.1.4.1.5491.10.1.7.1ScalarrupsTestIdread-writeoptionalThe test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this docu…
1.3.6.1.4.1.5491.10.1.7.2ScalarrupsTestSpinLockread-writeoptionalA spin lock on the test subsystem. The spinlock is used as follows. Before starting a test, a manager-station should make sure that a test is not in progress a…
1.3.6.1.4.1.5491.10.1.7.3ScalarrupsTestResultsSummaryread-onlyoptionalThe results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test complete…
1.3.6.1.4.1.5491.10.1.7.4ScalarrupsTestResultsDetailread-onlyoptionalAdditional information about upsTestResultsSummary. If no additional information available, a zero length string is returned.
1.3.6.1.4.1.5491.10.1.7.5ScalarrupsTestStartTimeread-onlyoptionalThe value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of…
1.3.6.1.4.1.5491.10.1.7.6ScalarrupsTestElapsedTimeread-onlyoptionalThe amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of …
1.3.6.1.4.1.5491.10.1.7.7NoderupsWellKnownTests
1.3.6.1.4.1.5491.10.1.7.7.1NoderupsTestNoTestsInitiated
1.3.6.1.4.1.5491.10.1.7.7.2NoderupsTestAbortTestInProgress
1.3.6.1.4.1.5491.10.1.7.7.3NoderupsTestGeneralSystemsTest
1.3.6.1.4.1.5491.10.1.7.7.4NoderupsTestQuickBatteryTest
1.3.6.1.4.1.5491.10.1.7.7.5NoderupsTestDeepBatteryCalibration
1.3.6.1.4.1.5491.10.1.8NoderupsControl
1.3.6.1.4.1.5491.10.1.8.1ScalarrupsShutdownTyperead-writemandatoryThis object determines the nature of the action to be taken at the time when the countdown of the upsShutdownAfterDelay and upsRebootWithDuration objects reach…
1.3.6.1.4.1.5491.10.1.8.2ScalarrupsShutdownAfterDelayread-writemandatorySetting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdo…
1.3.6.1.4.1.5491.10.1.8.3ScalarrupsStartupAfterDelayread-writemandatorySetting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause …
1.3.6.1.4.1.5491.10.1.8.4ScalarrupsRebootWithDurationread-writemandatorySetting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the ti…
1.3.6.1.4.1.5491.10.1.8.5ScalarrupsAutoRestartread-writemandatorySetting this object to 'on' will cause the UPS system to restart after a shutdown if the shutdown occurred during a power loss as a result of either a upsShutd…
1.3.6.1.4.1.5491.10.1.10NoderupsTemperature
1.3.6.1.4.1.5491.10.1.10.1ScalarrupsSystemTemperatureread-onlymandatoryThe present temperature.
1.3.6.1.4.1.5491.10.1.10.2ScalarrupsPowerTemperature1read-onlymandatoryThe present temperature.
1.3.6.1.4.1.5491.10.1.10.3ScalarrupsPowerTemperature2read-onlymandatoryThe present temperature.
1.3.6.1.4.1.5491.10.1.10.4ScalarrupsPowerTemperature3read-onlymandatoryThe present temperature.
1.3.6.1.4.1.5491.10.1.10.5ScalarrupsChargerTemperatureread-onlymandatoryThe present temperature.
1.3.6.1.4.1.5491.10.1.10.6ScalarrupsBatteryPositiveTemperatureread-onlymandatoryThe present temperature.
1.3.6.1.4.1.5491.10.1.10.7ScalarrupsBatteryNegativeTemperatureread-onlymandatoryThe present temperature.
1.3.6.1.4.1.5491.10.1.10.8ScalarrupsBatteryExternalTemperatureread-onlymandatoryThe present temperature.
1.3.6.1.4.1.5491.10.1.20NoderupsMPS
1.3.6.1.4.1.5491.10.1.20.1ScalarmpsAlarmGroupSread-onlymandatoryThe alarm group s.
1.3.6.1.4.1.5491.10.1.20.2ScalarmpsAlarmGroupCread-onlymandatoryThe alarm group c.
1.3.6.1.4.1.5491.10.1.20.3ScalarmpsAlarmGroupBread-onlymandatoryThe alarm group b.
1.3.6.1.4.1.5491.10.1.20.4ScalarmpsAlarmGroupRread-onlymandatoryThe alarm group r.
1.3.6.1.4.1.5491.10.1.20.5ScalarmpsAlarmGroupRIread-onlymandatoryThe alarm group RI.
1.3.6.1.4.1.5491.10.1.20.6ScalarmpsAlarmGroupIread-onlymandatoryThe alarm group I.
1.3.6.1.4.1.5491.10.1.20.7ScalarmpsAlarmGroupA0read-onlymandatoryThe alarm group A0.
1.3.6.1.4.1.5491.10.1.20.8ScalarmpsAlarmGroupA1read-onlymandatoryThe alarm group A1.
1.3.6.1.4.1.5491.10.1.20.9ScalarmpsAlarmGroupA2read-onlymandatoryThe alarm group A2.
1.3.6.1.4.1.5491.10.1.20.10ScalarmpsAlarmGroupA3read-onlymandatoryThe alarm group A3.
1.3.6.1.4.1.5491.10.1.20.11ScalarmpsAlarmGroupA4read-onlymandatoryThe alarm group A4.
1.3.6.1.4.1.5491.10.1.20.12ScalarmpsAlarmGroupA5read-onlymandatoryThe alarm group A5.
1.3.6.1.4.1.5491.10.1.21NoderupsMST
1.3.6.1.4.1.5491.10.1.21.1ScalarmstWarningGroupW0W1read-onlymandatoryThe anomaly group W0W1.
1.3.6.1.4.1.5491.10.1.21.2ScalarmstAnomalyGroupA0A1read-onlymandatoryThe anomaly group A0A1.
1.3.6.1.4.1.5491.10.1.21.3ScalarmstAnomalyGroupA2A3read-onlymandatoryThe anomaly group A2A3.
1.3.6.1.4.1.5491.10.1.21.4ScalarmstAnomalyGroupA4A5read-onlymandatoryThe anomaly group A4A5.
1.3.6.1.4.1.5491.10.1.21.5ScalarmstFaultGroupF0F1read-onlymandatoryThe fault group F0F1.
1.3.6.1.4.1.5491.10.1.21.6ScalarmstFaultGroupF2F3read-onlymandatoryThe fault group F2F3.
1.3.6.1.4.1.5491.10.1.21.7ScalarmstFaultGroupF4F5read-onlymandatoryThe fault group F4F5.
1.3.6.1.4.1.5491.10.1.21.8ScalarmstLockGroupL0L1read-onlymandatoryThe lock group L0L1.
1.3.6.1.4.1.5491.10.1.21.9ScalarmstLockGroupL2L3read-onlymandatoryThe lock group L2L3.
1.3.6.1.4.1.5491.10.1.21.10ScalarmstLockGroupL4L5read-onlymandatoryThe lock group L4L5.
1.3.6.1.4.1.5491.10.1.21.11ScalarmstEventGroupE0E1read-onlymandatoryThe event group E0E1.
1.3.6.1.4.1.5491.10.1.22NoderupsMPW
1.3.6.1.4.1.5491.10.1.22.1ScalarmpwSystemStatusGroup1read-onlymandatoryThe system status group 1.
1.3.6.1.4.1.5491.10.1.22.2ScalarmpwSystemStatusGroup2read-onlymandatoryThe system status group 2.
1.3.6.1.4.1.5491.10.1.22.3ScalarmpwSystemStatusGroup3read-onlymandatoryThe system status group 3.
1.3.6.1.4.1.5491.10.1.22.4ScalarmpwBypassModuleAlarmGroupread-onlymandatoryThe bypass module alarm group.
1.3.6.1.4.1.5491.10.1.22.5ScalarmpwPowerModule1AlarmGroupread-onlymandatoryThe power module 1 alarm group.
1.3.6.1.4.1.5491.10.1.22.6ScalarmpwPowerModule2AlarmGroupread-onlymandatoryThe power module 2 alarm group.
1.3.6.1.4.1.5491.10.1.22.7ScalarmpwPowerModule3AlarmGroupread-onlymandatoryThe power module 3 alarm group.
1.3.6.1.4.1.5491.10.1.22.8ScalarmpwPowerModule4AlarmGroupread-onlymandatoryThe power module 4 alarm group.
1.3.6.1.4.1.5491.10.1.22.9ScalarmpwPowerModule5AlarmGroupread-onlymandatoryThe power module 5 alarm group.
1.3.6.1.4.1.5491.10.1.22.10ScalarmpwPowerModule6AlarmGroupread-onlymandatoryThe power module 6 alarm group.
1.3.6.1.4.1.5491.10.1.22.11ScalarmpwPowerModule7AlarmGroupread-onlymandatoryThe power module 7 alarm group.
1.3.6.1.4.1.5491.10.1.22.12ScalarmpwBypassModuleStatusread-onlymandatoryThe bypass module status.
1.3.6.1.4.1.5491.10.1.22.13ScalarmpwPowerModule1Statusread-onlymandatoryThe status of power module 1.
1.3.6.1.4.1.5491.10.1.22.14ScalarmpwPowerModule2Statusread-onlymandatoryThe status of power module 2.
1.3.6.1.4.1.5491.10.1.22.15ScalarmpwPowerModule3Statusread-onlymandatoryThe status of power module 3.
1.3.6.1.4.1.5491.10.1.22.16ScalarmpwPowerModule4Statusread-onlymandatoryThe status of power module 4.
1.3.6.1.4.1.5491.10.1.22.17ScalarmpwPowerModule5Statusread-onlymandatoryThe status of power module 5.
1.3.6.1.4.1.5491.10.1.22.18ScalarmpwPowerModule6Statusread-onlymandatoryThe status of power module 6.
1.3.6.1.4.1.5491.10.1.22.19ScalarmpwPowerModule7Statusread-onlymandatoryThe status of power module 7.
1.3.6.1.4.1.5491.10.1.22.20NodempwControl
1.3.6.1.4.1.5491.10.1.22.20.1ScalarmpwCommandCoderead-writemandatoryCommand code.
1.3.6.1.4.1.5491.10.1.22.20.2ScalarmpwShutdownDelayread-writemandatoryShutdown delay.
1.3.6.1.4.1.5491.10.1.22.20.3ScalarmpwRestoreDelayread-writemandatoryRestore delay.
1.3.6.1.4.1.5491.10.1.22.20.4ScalarmpwModuleApplyCommandread-writemandatoryModule apply command
1.3.6.1.4.1.5491.10.1.22.20.5ScalarmpwCommandResultread-onlymandatoryResult of command.
1.3.6.1.4.1.5491.10.2NoderupsTraps
1.3.6.1.4.1.5491.10.2.1NoderupsTrapOnBatteryThe UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on …
1.3.6.1.4.1.5491.10.2.2NoderupsTrapTestCompletedThis trap is sent upon completion of a UPS diagnostic test.
1.3.6.1.4.1.5491.10.2.3NoderupsTrapAlarmEntryAddedThis trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for rupsAlarmOnBattery and rupsAlarm…
1.3.6.1.4.1.5491.10.2.4NoderupsTrapAlarmEntryRemovedThis trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for rupsAlarmTestInProgress.
Type Definitions
NameSyntaxStatusDescription
NonNegativeIntegerINTEGER (0..2147483647)currentThis data type is a non-negative value.
PositiveIntegerINTEGER (1..2147483647)currentThis data type is a non-zero and non-negative value.