ROOMALERT12E-MIB
85 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | Counter enterprises IpAddress TimeTicks |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20916 | Nodeavtech | |||
| 1.3.6.1.4.1.20916.1 | Nodeproducts | |||
| 1.3.6.1.4.1.20916.1.10 | Noderoomalert12E | |||
| 1.3.6.1.4.1.20916.1.10.1 | Nodesensors | |||
| 1.3.6.1.4.1.20916.1.10.1 | Nodetempalarm1-12E | A tempalarm1 trap signifies that the current temperature on external sensor 1 is outside the defined high or low threshold. | ||
| 1.3.6.1.4.1.20916.1.10.1.1 | Nodeinternal-sen | |||
| 1.3.6.1.4.1.20916.1.10.1.1.1 | Scalarinternal-sen-1 | read-only | mandatory | This value represents the current internal temperature in Celsius |
| 1.3.6.1.4.1.20916.1.10.1.1.2 | Scalarinternal-sen-2 | read-only | mandatory | This value represents the current internal temperature in Fahrenheit. |
| 1.3.6.1.4.1.20916.1.10.1.1.3 | Scalarinternal-sen-3 | read-only | mandatory | The internal sensor's label |
| 1.3.6.1.4.1.20916.1.10.1.2 | Nodedigital-sen1 | |||
| 1.3.6.1.4.1.20916.1.10.1.2.1 | Scalardigital-sen1-1 | read-only | mandatory | If this sensor is a Temperature, Temp/Humidity, Temp/Analog, or Temp/Active Power sensor, this value represents the current temperature in Celsius. |
| 1.3.6.1.4.1.20916.1.10.1.2.2 | Scalardigital-sen1-2 | read-only | mandatory | If this sensor is a Temperature, Temp/Humidity, Temp/Analog, or Temp/Active Power sensor, this value represents the current temperature in Fahrenheit. |
| 1.3.6.1.4.1.20916.1.10.1.2.3 | Scalardigital-sen1-3 | read-only | mandatory | If this sensor is a Temp/Humidity sensor, this value represents the current relative humidity in % Relative Humidity. If this sensor is a Temp/Analog sensor, t… |
| 1.3.6.1.4.1.20916.1.10.1.2.4 | Scalardigital-sen1-4 | read-only | mandatory | If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Fahrenheit. If this sensor is a Temp/Analog sensor, this value repres… |
| 1.3.6.1.4.1.20916.1.10.1.2.5 | Scalardigital-sen1-5 | read-only | mandatory | If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Celsius. |
| 1.3.6.1.4.1.20916.1.10.1.2.6 | Scalardigital-sen1-6 | read-only | mandatory | If this sensor is a Temp/Humidity sensor, this value represents the current dew point in Celsius. |
| 1.3.6.1.4.1.20916.1.10.1.2.7 | Scalardigital-sen1-7 | read-only | mandatory | If this sensor is a Temp/Humidity sensor, this value represents the current dew point in Fahrenheit. |
| 1.3.6.1.4.1.20916.1.10.1.2.8 | Scalardigital-sen1-8 | read-only | mandatory | The sensor's label |
| 1.3.6.1.4.1.20916.1.10.1.3 | Nodedigital-sen2 | |||
| 1.3.6.1.4.1.20916.1.10.1.3.1 | Scalardigital-sen2-1 | read-only | mandatory | If this sensor is a Temperature, Temp/Humidity, Temp/Analog, or Temp/Active Power sensor, this value represents the current temperature in Celsius. |
| 1.3.6.1.4.1.20916.1.10.1.3.2 | Scalardigital-sen2-2 | read-only | mandatory | If this sensor is a Temperature, Temp/Humidity, Temp/Analog, or Temp/Active Power sensor, this value represents the current temperature in Fahrenheit. |
| 1.3.6.1.4.1.20916.1.10.1.3.3 | Scalardigital-sen2-3 | read-only | mandatory | If this sensor is a Temp/Humidity sensor, this value represents the current relative humidity in % Relative Humidity. If this sensor is a Temp/Analog sensor, t… |
| 1.3.6.1.4.1.20916.1.10.1.3.4 | Scalardigital-sen2-4 | read-only | mandatory | If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Fahrenheit. If this sensor is a Temp/Analog sensor, this value repres… |
| 1.3.6.1.4.1.20916.1.10.1.3.5 | Scalardigital-sen2-5 | read-only | mandatory | If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Celsius. |
| 1.3.6.1.4.1.20916.1.10.1.3.6 | Scalardigital-sen2-6 | read-only | mandatory | If this sensor is a Temp/Humidity sensor, this value represents the current dew point in Celsius. |
| 1.3.6.1.4.1.20916.1.10.1.3.7 | Scalardigital-sen2-7 | read-only | mandatory | If this sensor is a Temp/Humidity sensor, this value represents the current dew point in Fahrenheit. |
| 1.3.6.1.4.1.20916.1.10.1.3.8 | Scalardigital-sen2-8 | read-only | mandatory | The sensor's label |
| 1.3.6.1.4.1.20916.1.10.1.4 | Nodedigital-sen3 | |||
| 1.3.6.1.4.1.20916.1.10.1.4.1 | Scalardigital-sen3-1 | read-only | mandatory | If this sensor is a Temperature, Temp/Humidity, Temp/Analog, or Temp/Active Power sensor, this value represents the current temperature in Celsius. |
| 1.3.6.1.4.1.20916.1.10.1.4.2 | Scalardigital-sen3-2 | read-only | mandatory | If this sensor is a Temperature, Temp/Humidity, Temp/Analog, or Temp/Active Power sensor, this value represents the current temperature in Fahrenheit. |
| 1.3.6.1.4.1.20916.1.10.1.4.3 | Scalardigital-sen3-3 | read-only | mandatory | If this sensor is a Temp/Humidity sensor, this value represents the current relative humidity in % Relative Humidity. If this sensor is a Temp/Analog sensor, t… |
| 1.3.6.1.4.1.20916.1.10.1.4.4 | Scalardigital-sen3-4 | read-only | mandatory | If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Fahrenheit. If this sensor is a Temp/Analog sensor, this value repres… |
| 1.3.6.1.4.1.20916.1.10.1.4.5 | Scalardigital-sen3-5 | read-only | mandatory | If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Celsius. |
| 1.3.6.1.4.1.20916.1.10.1.4.6 | Scalardigital-sen3-6 | read-only | mandatory | If this sensor is a Temp/Humidity sensor, this value represents the current dew point in Celsius. |
| 1.3.6.1.4.1.20916.1.10.1.4.7 | Scalardigital-sen3-7 | read-only | mandatory | If this sensor is a Temp/Humidity sensor, this value represents the current dew point in Fahrenheit. |
| 1.3.6.1.4.1.20916.1.10.1.4.8 | Scalardigital-sen3-8 | read-only | mandatory | The sensor's label |
| 1.3.6.1.4.1.20916.1.10.1.5 | Nodeswitch1 | |||
| 1.3.6.1.4.1.20916.1.10.1.5.1 | Scalarswitch-sen1-1 | read-only | mandatory | The reading for switch sensor 1 (0 = OPEN, 1 = CLOSED). |
| 1.3.6.1.4.1.20916.1.10.1.5.2 | Scalarswitch-sen1-2 | read-only | mandatory | The label for switch sensor 1. |
| 1.3.6.1.4.1.20916.1.10.1.6 | Nodeswitch2 | |||
| 1.3.6.1.4.1.20916.1.10.1.6.1 | Scalarswitch-sen2 | read-only | mandatory | The reading for switch sensor 2 (0 = OPEN, 1 = CLOSED). |
| 1.3.6.1.4.1.20916.1.10.1.6.2 | Scalarswitch-sen2-2 | read-only | mandatory | The label for switch sensor 2. |
| 1.3.6.1.4.1.20916.1.10.1.7 | Nodeswitch3 | |||
| 1.3.6.1.4.1.20916.1.10.1.7.1 | Scalarswitch-sen3 | read-only | mandatory | The reading for switch sensor 3 (0 = OPEN, 1 = CLOSED). |
| 1.3.6.1.4.1.20916.1.10.1.7.2 | Scalarswitch-sen3-2 | read-only | mandatory | The label for switch sensor 3. |
| 1.3.6.1.4.1.20916.1.10.1.8 | Nodeswitch4 | |||
| 1.3.6.1.4.1.20916.1.10.1.8.1 | Scalarswitch-sen4 | read-only | mandatory | The reading for switch sensor 4 (0 = OPEN, 1 = CLOSED). |
| 1.3.6.1.4.1.20916.1.10.1.8.2 | Scalarswitch-sen4-2 | read-only | mandatory | The label for switch sensor 4. |
| 1.3.6.1.4.1.20916.1.10.1.9 | Nodeanalog | |||
| 1.3.6.1.4.1.20916.1.10.1.9.1 | Scalaranalog-1 | read-only | mandatory | The current status of the Room Alert 12E analog input (0-5VDC). |
| 1.3.6.1.4.1.20916.1.10.1.9.2 | Scalaranalog-2 | read-only | mandatory | The analog sensor's label. |
| 1.3.6.1.4.1.20916.1.10.1.9.3 | Scalaranalog-3 | read-only | mandatory | The current status of the Room Alert 12E analog input (user-defined scale). |
| 1.3.6.1.4.1.20916.1.10.1.10 | Noderelay | |||
| 1.3.6.1.4.1.20916.1.10.1.10.1 | Scalarrelay-1 | read-write | mandatory | The current status of the Room Alert 12E relay output. |
| 1.3.6.1.4.1.20916.1.10.1.10.2 | Scalarrelay-2 | read-only | mandatory | The relay output's label. |
| 1.3.6.1.4.1.20916.1.10.2 | NodelightTower | |||
| 1.3.6.1.4.1.20916.1.10.2 | Noderoom-alert-12E-snmp-trap | A room-alert-12E-snmp-trap indicates that an alarm condition has occurred on the sensor inidcated by the alarmMessage variable. | ||
| 1.3.6.1.4.1.20916.1.10.2.1 | ScalarlightTower-RE | read-write | mandatory | The status of the red LED on the Light Tower. |
| 1.3.6.1.4.1.20916.1.10.2.2 | ScalarlightTower-OR | read-write | mandatory | The status of the orange LED on the Light Tower. |
| 1.3.6.1.4.1.20916.1.10.2.3 | ScalarlightTower-GR | read-write | mandatory | The status of the green LED on the Light Tower. |
| 1.3.6.1.4.1.20916.1.10.2.4 | ScalarlightTower-WH | read-write | mandatory | The status of the white LED on the Light Tower. |
| 1.3.6.1.4.1.20916.1.10.2.5 | ScalarlightTower-BL | read-write | mandatory | The status of the blue LED on the Light Tower. |
| 1.3.6.1.4.1.20916.1.10.2.6 | ScalarlightTower-A1 | read-write | mandatory | The status of the 1st audio alarm on the Light Tower. |
| 1.3.6.1.4.1.20916.1.10.2.7 | ScalarlightTower-A2 | read-write | mandatory | The status of the 2nd audio alarm on the Light Tower. |
| 1.3.6.1.4.1.20916.1.10.2.8 | ScalarlightTower-RL | read-write | mandatory | The status of the LTA's on-board relay output |
| 1.3.6.1.4.1.20916.1.10.3 | Nodetempalarm2-12E | A tempalarm2 trap signifies that the current temperature on external sensor 2 is outside the defined high or low threshold. | ||
| 1.3.6.1.4.1.20916.1.10.3 | Nodetraps | |||
| 1.3.6.1.4.1.20916.1.10.3.1 | Scalaralarmmessage | read-only | mandatory | Last Alarm Message |
| 1.3.6.1.4.1.20916.1.10.4 | Nodetempclear2-12E | A tempclear2 trap signifies that the current temperature on external sensor 2 has returned to a normal condition and is within the defined high or low threshol… | ||
| 1.3.6.1.4.1.20916.1.10.5 | Nodetempalarm3-12E | A tempalarm3 trap signifies that the current temperature on external sensor 3 is outside the defined high or low threshold. | ||
| 1.3.6.1.4.1.20916.1.10.6 | Nodetempclear3-12E | A tempclear3 trap signifies that the current temperature on external sensor 3 has returned to a normal condition and is within the defined high or low threshol… | ||
| 1.3.6.1.4.1.20916.1.10.7 | Nodehumidityalarm1-12E | A humidityalarm1 trap signifies that the current humidity on external sensor 1 is outside the defined high or low threshold. | ||
| 1.3.6.1.4.1.20916.1.10.8 | Nodehumidityclear1-12E | A humidityclear1 trap signifies that the current humidity on external sensor 1 has returned to a normal condition and is within the defined high or low thresho… | ||
| 1.3.6.1.4.1.20916.1.10.9 | Nodehumidityalarm2-12E | A humidityalarm2 trap signifies that the current humidity on external sensor 2 is outside the defined high or low threshold. | ||
| 1.3.6.1.4.1.20916.1.10.10 | Nodehumidityclear2-12E | A humidityclear2 trap signifies that the current humidity on external sensor 2 has returned to a normal condition and is within the defined high or low thresho… | ||
| 1.3.6.1.4.1.20916.1.10.11 | Nodehumidityalarm3-12E | A humidityalarm3 trap signifies that the current humidity on external sensor 3 is outside the defined high or low threshold. | ||
| 1.3.6.1.4.1.20916.1.10.12 | Nodehumidityclear3-12E | A humidityclear3 trap signifies that the current humidity on external sensor 3 has returned to a normal condition and is within the defined high or low thresho… | ||
| 1.3.6.1.4.1.20916.1.10.13 | Nodeswitchalarm1-12E | A switchalarm1 trap signifies that switch sensor 1 is in an alarm state. | ||
| 1.3.6.1.4.1.20916.1.10.14 | Nodeswitchclear1-12E | A switchclear1 trap signifies that the switch sensor 1 has returned to a normal state. | ||
| 1.3.6.1.4.1.20916.1.10.15 | Nodeswitchalarm2-12E | A switchalarm2 trap signifies that switch sensor 2 is in an alarm state. | ||
| 1.3.6.1.4.1.20916.1.10.16 | Nodeswitchclear2-12E | A switchclear2 trap signifies that the switch sensor 2 has returned to a normal state. | ||
| 1.3.6.1.4.1.20916.1.10.17 | Nodeswitchalarm3-12E | A switchalarm3 trap signifies that switch sensor 3 is in an alarm state. | ||
| 1.3.6.1.4.1.20916.1.10.18 | Nodeswitchclear3-12E | A switchclear3 trap signifies that the switch sensor 3 has returned to a normal state. | ||
| 1.3.6.1.4.1.20916.1.10.19 | Nodeswitchalarm4-12E | A switchalarm4 trap signifies that switch sensor 4 is in an alarm state. | ||
| 1.3.6.1.4.1.20916.1.10.20 | Nodeswitchclear4-12E | A switchclear4 trap signifies that the switch sensor 4 has returned to a normal state. |