ROOMALERT32S-MIB
178 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC1155-SMI | enterprises Gauge IpAddress TimeTicks |
| RFC1213-MIB | DisplayString system |
| SNMPv2-SMI | NOTIFICATION-TYPE |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20916 | Nodeavtech | |||
| 1.3.6.1.4.1.20916.1 | Nodeproducts | |||
| 1.3.6.1.4.1.20916.1.11 | Noderoomalert32S | |||
| 1.3.6.1.4.1.20916.1.11.1 | Nodesensors | |||
| 1.3.6.1.4.1.20916.1.11.1.1 | Nodeinternal | |||
| 1.3.6.1.4.1.20916.1.11.1.1.1 | Nodetemperature | |||
| 1.3.6.1.4.1.20916.1.11.1.1.1.1 | Scalarinternal-tempf | read-only | mandatory | The internal temperature reading in Fahrenheit. |
| 1.3.6.1.4.1.20916.1.11.1.1.1.2 | Scalarinternal-tempc | read-only | mandatory | The internal temperature reading in Celsius. |
| 1.3.6.1.4.1.20916.1.11.1.1.2 | Nodehumidity | |||
| 1.3.6.1.4.1.20916.1.11.1.1.2.1 | Scalarinternal-humidity | read-only | mandatory | The internal relative humidity reading in %RH. |
| 1.3.6.1.4.1.20916.1.11.1.1.3 | Nodepower | |||
| 1.3.6.1.4.1.20916.1.11.1.1.3.1 | Scalarinternal-power | read-only | mandatory | The current status of the Room Alert 32S power supply. A '1' indicates the unit is running on AC/Utility power. A '0' indicates the unit is running on battery … |
| 1.3.6.1.4.1.20916.1.11.1.1.4 | Nodeheat-index | |||
| 1.3.6.1.4.1.20916.1.11.1.1.4.1 | Scalarinternal-heat-index | read-only | optional | The internal heat index reading in Fahrenheit. |
| 1.3.6.1.4.1.20916.1.11.1.1.4.2 | Scalarinternal-heat-indexC | read-only | optional | The internal heat index reading in Celsius. |
| 1.3.6.1.4.1.20916.1.11.1.1.5 | Nodeanalog | |||
| 1.3.6.1.4.1.20916.1.11.1.1.5.1 | Scalarinternal-analog1 | read-only | mandatory | The current status of the Room Alert 32S analog input (0-5VDC). |
| 1.3.6.1.4.1.20916.1.11.1.1.5.2 | Scalarinternal-analog2 | read-only | mandatory | The current status of the Room Alert 32S analog input (0-5VDC). |
| 1.3.6.1.4.1.20916.1.11.1.1.5.3 | Scalarinternal-analog-computed1 | read-only | mandatory | The current computed value of the Room Alert 32S analog input. |
| 1.3.6.1.4.1.20916.1.11.1.1.5.4 | Scalarinternal-analog-computed-units1 | read-only | mandatory | The computed analog units for the Room Alert 32S analog input.. |
| 1.3.6.1.4.1.20916.1.11.1.1.5.5 | Scalarinternal-analog-computed2 | read-only | mandatory | The current computed value of the Room Alert 32S analog input. |
| 1.3.6.1.4.1.20916.1.11.1.1.5.6 | Scalarinternal-analog-computed-units2 | read-only | mandatory | The computed analog units for the Room Alert 32S analog input.. |
| 1.3.6.1.4.1.20916.1.11.1.1.6 | Noderelay | |||
| 1.3.6.1.4.1.20916.1.11.1.1.6.1 | Scalarinternal-relay1 | read-write | mandatory | The status of the on-board relay output |
| 1.3.6.1.4.1.20916.1.11.1.1.6.2 | Scalarinternal-relay2 | read-write | mandatory | The status of the on-board relay output |
| 1.3.6.1.4.1.20916.1.11.1.1.7 | Nodedew-point | |||
| 1.3.6.1.4.1.20916.1.11.1.1.7.1 | Scalarinternal-dew-point-c | read-only | optional | The internal dew-point reading in Celsius. |
| 1.3.6.1.4.1.20916.1.11.1.1.7.2 | Scalarinternal-dew-point-f | read-only | optional | The internal dew-point reading in Fahrenheit. |
| 1.3.6.1.4.1.20916.1.11.1.2 | Nodedigital | |||
| 1.3.6.1.4.1.20916.1.11.1.2.1 | Nodedigital-sen1 | |||
| 1.3.6.1.4.1.20916.1.11.1.2.1.1 | Scalardigital-sen1-1 | read-only | mandatory | The sensor's current temperature in Celsius. |
| 1.3.6.1.4.1.20916.1.11.1.2.1.2 | Scalardigital-sen1-2 | read-only | mandatory | The sensor's current temperature in Fahrenheit. |
| 1.3.6.1.4.1.20916.1.11.1.2.1.3 | Scalardigital-sen1-3 | read-only | mandatory | Varies by sensor type: current % relative humidity, voltage reading (V), power state (1=Power Detected, 0=No Power Detected), thermocouple temperature (C), air… |
| 1.3.6.1.4.1.20916.1.11.1.2.1.4 | Scalardigital-sen1-4 | read-only | mandatory | Varies by sensor type: current heat index (F), custom analog reading, thermocouple temperature (F), air speed (f/m), or PM10 (mcg/m3). |
| 1.3.6.1.4.1.20916.1.11.1.2.1.5 | Scalardigital-sen1-5 | read-only | mandatory | Varies by sensor type: current heat index (C), thermocouple fault code (0=No Fault), air flow (CMH), or particulate fault code (0=No Fault). |
| 1.3.6.1.4.1.20916.1.11.1.2.1.6 | Scalardigital-sen1-6 | read-only | mandatory | Varies by sensor type: current dew point (C) or air flow (CFM). |
| 1.3.6.1.4.1.20916.1.11.1.2.1.7 | Scalardigital-sen1-7 | read-only | mandatory | Varies by sensor type: current dew point (F). |
| 1.3.6.1.4.1.20916.1.11.1.2.1.8 | Scalardigital-sen1-8 | read-only | mandatory | The computed analog units for the Room Alert 32S analog input.. |
| 1.3.6.1.4.1.20916.1.11.1.2.2 | Nodedigital-sen2 | |||
| 1.3.6.1.4.1.20916.1.11.1.2.2.1 | Scalardigital-sen2-1 | read-only | mandatory | The sensor's current temperature in Celsius. |
| 1.3.6.1.4.1.20916.1.11.1.2.2.2 | Scalardigital-sen2-2 | read-only | mandatory | The sensor's current temperature in Fahrenheit. |
| 1.3.6.1.4.1.20916.1.11.1.2.2.3 | Scalardigital-sen2-3 | read-only | mandatory | Varies by sensor type: current % relative humidity, voltage reading (V), power state (1=Power Detected, 0=No Power Detected), thermocouple temperature (C), air… |
| 1.3.6.1.4.1.20916.1.11.1.2.2.4 | Scalardigital-sen2-4 | read-only | mandatory | Varies by sensor type: current heat index (F), custom analog reading, thermocouple temperature (F), air speed (f/m), or PM10 (mcg/m3). |
| 1.3.6.1.4.1.20916.1.11.1.2.2.5 | Scalardigital-sen2-5 | read-only | mandatory | Varies by sensor type: current heat index (C), thermocouple fault code (0=No Fault), air flow (CMH), or particulate fault code (0=No Fault). |
| 1.3.6.1.4.1.20916.1.11.1.2.2.6 | Scalardigital-sen2-6 | read-only | mandatory | Varies by sensor type: current dew point (C) or air flow (CFM). |
| 1.3.6.1.4.1.20916.1.11.1.2.2.7 | Scalardigital-sen2-7 | read-only | mandatory | Varies by sensor type: current dew point (F). |
| 1.3.6.1.4.1.20916.1.11.1.2.2.8 | Scalardigital-sen2-8 | read-only | mandatory | The computed analog units for the Room Alert 32S analog input.. |
| 1.3.6.1.4.1.20916.1.11.1.2.3 | Nodedigital-sen3 | |||
| 1.3.6.1.4.1.20916.1.11.1.2.3.1 | Scalardigital-sen3-1 | read-only | mandatory | The sensor's current temperature in Celsius. |
| 1.3.6.1.4.1.20916.1.11.1.2.3.2 | Scalardigital-sen3-2 | read-only | mandatory | The sensor's current temperature in Fahrenheit. |
| 1.3.6.1.4.1.20916.1.11.1.2.3.3 | Scalardigital-sen3-3 | read-only | mandatory | Varies by sensor type: current % relative humidity, voltage reading (V), power state (1=Power Detected, 0=No Power Detected), thermocouple temperature (C), air… |
| 1.3.6.1.4.1.20916.1.11.1.2.3.4 | Scalardigital-sen3-4 | read-only | mandatory | Varies by sensor type: current heat index (F), custom analog reading, thermocouple temperature (F), air speed (f/m), or PM10 (mcg/m3). |
| 1.3.6.1.4.1.20916.1.11.1.2.3.5 | Scalardigital-sen3-5 | read-only | mandatory | Varies by sensor type: current heat index (C), thermocouple fault code (0=No Fault), air flow (CMH), or particulate fault code (0=No Fault). |
| 1.3.6.1.4.1.20916.1.11.1.2.3.6 | Scalardigital-sen3-6 | read-only | mandatory | Varies by sensor type: current dew point (C) or air flow (CFM). |
| 1.3.6.1.4.1.20916.1.11.1.2.3.7 | Scalardigital-sen3-7 | read-only | mandatory | Varies by sensor type: current dew point (F). |
| 1.3.6.1.4.1.20916.1.11.1.2.3.8 | Scalardigital-sen3-8 | read-only | mandatory | The computed analog units for the Room Alert 32S analog input.. |
| 1.3.6.1.4.1.20916.1.11.1.2.4 | Nodedigital-sen4 | |||
| 1.3.6.1.4.1.20916.1.11.1.2.4.1 | Scalardigital-sen4-1 | read-only | mandatory | The sensor's current temperature in Celsius. |
| 1.3.6.1.4.1.20916.1.11.1.2.4.2 | Scalardigital-sen4-2 | read-only | mandatory | The sensor's current temperature in Fahrenheit. |
| 1.3.6.1.4.1.20916.1.11.1.2.4.3 | Scalardigital-sen4-3 | read-only | mandatory | Varies by sensor type: current % relative humidity, voltage reading (V), power state (1=Power Detected, 0=No Power Detected), thermocouple temperature (C), air… |
| 1.3.6.1.4.1.20916.1.11.1.2.4.4 | Scalardigital-sen4-4 | read-only | mandatory | Varies by sensor type: current heat index (F), custom analog reading, thermocouple temperature (F), air speed (f/m), or PM10 (mcg/m3). |
| 1.3.6.1.4.1.20916.1.11.1.2.4.5 | Scalardigital-sen4-5 | read-only | mandatory | Varies by sensor type: current heat index (C), thermocouple fault code (0=No Fault), air flow (CMH), or particulate fault code (0=No Fault). |
| 1.3.6.1.4.1.20916.1.11.1.2.4.6 | Scalardigital-sen4-6 | read-only | mandatory | Varies by sensor type: current dew point (C) or air flow (CFM). |
| 1.3.6.1.4.1.20916.1.11.1.2.4.7 | Scalardigital-sen4-7 | read-only | mandatory | Varies by sensor type: current dew point (F). |
| 1.3.6.1.4.1.20916.1.11.1.2.4.8 | Scalardigital-sen4-8 | read-only | mandatory | The computed analog units for the Room Alert 32S analog input.. |
| 1.3.6.1.4.1.20916.1.11.1.2.5 | Nodedigital-sen5 | |||
| 1.3.6.1.4.1.20916.1.11.1.2.5.1 | Scalardigital-sen5-1 | read-only | mandatory | The sensor's current temperature in Celsius. |
| 1.3.6.1.4.1.20916.1.11.1.2.5.2 | Scalardigital-sen5-2 | read-only | mandatory | The sensor's current temperature in Fahrenheit. |
| 1.3.6.1.4.1.20916.1.11.1.2.5.3 | Scalardigital-sen5-3 | read-only | mandatory | Varies by sensor type: current % relative humidity, voltage reading (V), power state (1=Power Detected, 0=No Power Detected), thermocouple temperature (C), air… |
| 1.3.6.1.4.1.20916.1.11.1.2.5.4 | Scalardigital-sen5-4 | read-only | mandatory | Varies by sensor type: current heat index (F), custom analog reading, thermocouple temperature (F), air speed (f/m), or PM10 (mcg/m3). |
| 1.3.6.1.4.1.20916.1.11.1.2.5.5 | Scalardigital-sen5-5 | read-only | mandatory | Varies by sensor type: current heat index (C), thermocouple fault code (0=No Fault), air flow (CMH), or particulate fault code (0=No Fault). |
| 1.3.6.1.4.1.20916.1.11.1.2.5.6 | Scalardigital-sen5-6 | read-only | mandatory | Varies by sensor type: current dew point (C) or air flow (CFM). |
| 1.3.6.1.4.1.20916.1.11.1.2.5.7 | Scalardigital-sen5-7 | read-only | mandatory | Varies by sensor type: current dew point (F). |
| 1.3.6.1.4.1.20916.1.11.1.2.5.8 | Scalardigital-sen5-8 | read-only | mandatory | The computed analog units for the Room Alert 32S analog input.. |
| 1.3.6.1.4.1.20916.1.11.1.2.6 | Nodedigital-sen6 | |||
| 1.3.6.1.4.1.20916.1.11.1.2.6.1 | Scalardigital-sen6-1 | read-only | mandatory | The sensor's current temperature in Celsius. |
| 1.3.6.1.4.1.20916.1.11.1.2.6.2 | Scalardigital-sen6-2 | read-only | mandatory | The sensor's current temperature in Fahrenheit. |
| 1.3.6.1.4.1.20916.1.11.1.2.6.3 | Scalardigital-sen6-3 | read-only | mandatory | Varies by sensor type: current % relative humidity, voltage reading (V), power state (1=Power Detected, 0=No Power Detected), thermocouple temperature (C), air… |
| 1.3.6.1.4.1.20916.1.11.1.2.6.4 | Scalardigital-sen6-4 | read-only | mandatory | Varies by sensor type: current heat index (F), custom analog reading, thermocouple temperature (F), air speed (f/m), or PM10 (mcg/m3). |
| 1.3.6.1.4.1.20916.1.11.1.2.6.5 | Scalardigital-sen6-5 | read-only | mandatory | Varies by sensor type: current heat index (C), thermocouple fault code (0=No Fault), air flow (CMH), or particulate fault code (0=No Fault). |
| 1.3.6.1.4.1.20916.1.11.1.2.6.6 | Scalardigital-sen6-6 | read-only | mandatory | Varies by sensor type: current dew point (C) or air flow (CFM). |
| 1.3.6.1.4.1.20916.1.11.1.2.6.7 | Scalardigital-sen6-7 | read-only | mandatory | Varies by sensor type: current dew point (F). |
| 1.3.6.1.4.1.20916.1.11.1.2.6.8 | Scalardigital-sen6-8 | read-only | mandatory | The computed analog units for the Room Alert 32S analog input.. |
| 1.3.6.1.4.1.20916.1.11.1.2.7 | Nodedigital-sen7 | |||
| 1.3.6.1.4.1.20916.1.11.1.2.7.1 | Scalardigital-sen7-1 | read-only | mandatory | The sensor's current temperature in Celsius. |
| 1.3.6.1.4.1.20916.1.11.1.2.7.2 | Scalardigital-sen7-2 | read-only | mandatory | The sensor's current temperature in Fahrenheit. |
| 1.3.6.1.4.1.20916.1.11.1.2.7.3 | Scalardigital-sen7-3 | read-only | mandatory | Varies by sensor type: current % relative humidity, voltage reading (V), power state (1=Power Detected, 0=No Power Detected), thermocouple temperature (C), air… |
| 1.3.6.1.4.1.20916.1.11.1.2.7.4 | Scalardigital-sen7-4 | read-only | mandatory | Varies by sensor type: current heat index (F), custom analog reading, thermocouple temperature (F), air speed (f/m), or PM10 (mcg/m3). |
| 1.3.6.1.4.1.20916.1.11.1.2.7.5 | Scalardigital-sen7-5 | read-only | mandatory | Varies by sensor type: current heat index (C), thermocouple fault code (0=No Fault), air flow (CMH), or particulate fault code (0=No Fault). |
| 1.3.6.1.4.1.20916.1.11.1.2.7.6 | Scalardigital-sen7-6 | read-only | mandatory | Varies by sensor type: current dew point (C) or air flow (CFM). |
| 1.3.6.1.4.1.20916.1.11.1.2.7.7 | Scalardigital-sen7-7 | read-only | mandatory | Varies by sensor type: current dew point (F). |
| 1.3.6.1.4.1.20916.1.11.1.2.7.8 | Scalardigital-sen7-8 | read-only | mandatory | The computed analog units for the Room Alert 32S analog input.. |
| 1.3.6.1.4.1.20916.1.11.1.2.8 | Nodedigital-sen8 | |||
| 1.3.6.1.4.1.20916.1.11.1.2.8.1 | Scalardigital-sen8-1 | read-only | mandatory | The sensor's current temperature in Celsius. |
| 1.3.6.1.4.1.20916.1.11.1.2.8.2 | Scalardigital-sen8-2 | read-only | mandatory | The sensor's current temperature in Fahrenheit. |
| 1.3.6.1.4.1.20916.1.11.1.2.8.3 | Scalardigital-sen8-3 | read-only | mandatory | Varies by sensor type: current % relative humidity, voltage reading (V), power state (1=Power Detected, 0=No Power Detected), thermocouple temperature (C), air… |
| 1.3.6.1.4.1.20916.1.11.1.2.8.4 | Scalardigital-sen8-4 | read-only | mandatory | Varies by sensor type: current heat index (F), custom analog reading, thermocouple temperature (F), air speed (f/m), or PM10 (mcg/m3). |
| 1.3.6.1.4.1.20916.1.11.1.2.8.5 | Scalardigital-sen8-5 | read-only | mandatory | Varies by sensor type: current heat index (C), thermocouple fault code (0=No Fault), air flow (CMH), or particulate fault code (0=No Fault). |
| 1.3.6.1.4.1.20916.1.11.1.2.8.6 | Scalardigital-sen8-6 | read-only | mandatory | Varies by sensor type: current dew point (C) or air flow (CFM). |
| 1.3.6.1.4.1.20916.1.11.1.2.8.7 | Scalardigital-sen8-7 | read-only | mandatory | Varies by sensor type: current dew point (F). |
| 1.3.6.1.4.1.20916.1.11.1.2.8.8 | Scalardigital-sen8-8 | read-only | mandatory | The computed analog units for the Room Alert 32S analog input.. |
| 1.3.6.1.4.1.20916.1.11.1.3 | Nodeswitch | |||
| 1.3.6.1.4.1.20916.1.11.1.3.1 | Scalarswitch-sen1 | read-only | mandatory | The reading for switch sensor 1 (0 = OPEN, 1 = CLOSED). |
| 1.3.6.1.4.1.20916.1.11.1.3.2 | Scalarswitch-sen2 | read-only | mandatory | The reading for switch sensor 2 (0 = OPEN, 1 = CLOSED). |
| 1.3.6.1.4.1.20916.1.11.1.3.3 | Scalarswitch-sen3 | read-only | mandatory | The reading for switch sensor 3 (0 = OPEN, 1 = CLOSED). |
| 1.3.6.1.4.1.20916.1.11.1.3.4 | Scalarswitch-sen4 | read-only | mandatory | The reading for switch sensor 4 (0 = OPEN, 1 = CLOSED). |
| 1.3.6.1.4.1.20916.1.11.1.3.5 | Scalarswitch-sen5 | read-only | mandatory | The reading for switch sensor 5 (0 = OPEN, 1 = CLOSED). |
| 1.3.6.1.4.1.20916.1.11.1.3.6 | Scalarswitch-sen6 | read-only | mandatory | The reading for switch sensor 6 (0 = OPEN, 1 = CLOSED). |
| 1.3.6.1.4.1.20916.1.11.1.3.7 | Scalarswitch-sen7 | read-only | mandatory | The reading for switch sensor 7 (0 = OPEN, 1 = CLOSED). |
| 1.3.6.1.4.1.20916.1.11.1.3.8 | Scalarswitch-sen8 | read-only | mandatory | The reading for switch sensor 8 (0 = OPEN, 1 = CLOSED). |
| 1.3.6.1.4.1.20916.1.11.1.3.9 | Scalarswitch-sen9 | read-only | mandatory | The reading for switch sensor 9 (0 = OPEN, 1 = CLOSED). |
| 1.3.6.1.4.1.20916.1.11.1.3.10 | Scalarswitch-sen10 | read-only | mandatory | The reading for switch sensor 10 (0 = OPEN, 1 = CLOSED). |
| 1.3.6.1.4.1.20916.1.11.1.3.11 | Scalarswitch-sen11 | read-only | mandatory | The reading for switch sensor 11 (0 = OPEN, 1 = CLOSED). |
| 1.3.6.1.4.1.20916.1.11.1.3.12 | Scalarswitch-sen12 | read-only | mandatory | The reading for switch sensor 12 (0 = OPEN, 1 = CLOSED). |
| 1.3.6.1.4.1.20916.1.11.1.3.13 | Scalarswitch-sen13 | read-only | mandatory | The reading for switch sensor 13 (0 = OPEN, 1 = CLOSED). |
| 1.3.6.1.4.1.20916.1.11.1.3.14 | Scalarswitch-sen14 | read-only | mandatory | The reading for switch sensor 14 (0 = OPEN, 1 = CLOSED). |
| 1.3.6.1.4.1.20916.1.11.1.3.15 | Scalarswitch-sen15 | read-only | mandatory | The reading for switch sensor 15 (0 = OPEN, 1 = CLOSED). |
| 1.3.6.1.4.1.20916.1.11.1.3.16 | Scalarswitch-sen16 | read-only | mandatory | The reading for switch sensor 16 (0 = OPEN, 1 = CLOSED). |
| 1.3.6.1.4.1.20916.1.11.1.4 | Nodelabels | |||
| 1.3.6.1.4.1.20916.1.11.1.4.1 | Nodeint-labels | |||
| 1.3.6.1.4.1.20916.1.11.1.4.1.1 | Scalarlabels-internal-sen1 | read-only | mandatory | Internal Sensor Label |
| 1.3.6.1.4.1.20916.1.11.1.4.1.2 | Scalarlabels-internal-sen2 | read-only | mandatory | Internal Power Sensor Label |
| 1.3.6.1.4.1.20916.1.11.1.4.2 | Nodedigital-labels | |||
| 1.3.6.1.4.1.20916.1.11.1.4.2.1 | Scalarlabels-digital-sen1 | read-only | mandatory | Digital Sensor Port 1 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.2.2 | Scalarlabels-digital-sen2 | read-only | mandatory | Digital Sensor Port 2 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.2.3 | Scalarlabels-digital-sen3 | read-only | mandatory | Digital Sensor Port 3 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.2.4 | Scalarlabels-digital-sen4 | read-only | mandatory | Digital Sensor Port 4 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.2.5 | Scalarlabels-digital-sen5 | read-only | mandatory | Digital Sensor Port 5 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.2.6 | Scalarlabels-digital-sen6 | read-only | mandatory | Digital Sensor Port 6 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.2.7 | Scalarlabels-digital-sen7 | read-only | mandatory | Digital Sensor Port 7 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.2.8 | Scalarlabels-digital-sen8 | read-only | mandatory | Digital Sensor Port 8 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.3 | Nodeswitch-labels | |||
| 1.3.6.1.4.1.20916.1.11.1.4.3.1 | Scalarlabels-switch-sen1 | read-only | mandatory | Switch 1 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.3.2 | Scalarlabels-switch-sen2 | read-only | mandatory | Switch 2 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.3.3 | Scalarlabels-switch-sen3 | read-only | mandatory | Switch 3 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.3.4 | Scalarlabels-switch-sen4 | read-only | mandatory | Switch 4 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.3.5 | Scalarlabels-switch-sen5 | read-only | mandatory | Switch 5 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.3.6 | Scalarlabels-switch-sen6 | read-only | mandatory | Switch 6 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.3.7 | Scalarlabels-switch-sen7 | read-only | mandatory | Switch 7 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.3.8 | Scalarlabels-switch-sen8 | read-only | mandatory | Switch 8 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.3.9 | Scalarlabels-switch-sen9 | read-only | mandatory | Switch 9 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.3.10 | Scalarlabels-switch-sen10 | read-only | mandatory | Switch 10 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.3.11 | Scalarlabels-switch-sen11 | read-only | mandatory | Switch 11 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.3.12 | Scalarlabels-switch-sen12 | read-only | mandatory | Switch 12 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.3.13 | Scalarlabels-switch-sen13 | read-only | mandatory | Switch 13 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.3.14 | Scalarlabels-switch-sen14 | read-only | mandatory | Switch 14 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.3.15 | Scalarlabels-switch-sen15 | read-only | mandatory | Switch 15 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.3.16 | Scalarlabels-switch-sen16 | read-only | mandatory | Switch 16 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.4 | Nodeanalog-labels | |||
| 1.3.6.1.4.1.20916.1.11.1.4.4.1 | Scalarlabels-analog-sen1 | read-only | mandatory | Analog Sensor 1 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.4.2 | Scalarlabels-analog-sen2 | read-only | mandatory | Analog Sensor 2 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.5 | Nodeinternal-relay-labels | |||
| 1.3.6.1.4.1.20916.1.11.1.4.5.1 | Scalarinternal-relay-labels1 | read-only | mandatory | Internal Relay 1 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.5.2 | Scalarinternal-relay-labels2 | read-only | mandatory | Internal Relay 2 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.6 | Nodeexternal-relay-labels | |||
| 1.3.6.1.4.1.20916.1.11.1.4.6.1 | Scalarexternal-relay-labels1 | read-only | mandatory | External Relay 1 Label |
| 1.3.6.1.4.1.20916.1.11.1.4.6.2 | Scalarexternal-relay-labels2 | read-only | mandatory | External Relay 2 Label |
| 1.3.6.1.4.1.20916.1.11.2 | Nodetraps | |||
| 1.3.6.1.4.1.20916.1.11.2.1 | Notificationalarmmessage | current | Indicates that an alarm condition has occurred on the sensor indicated by the alarmMessage variable. | |
| 1.3.6.1.4.1.20916.1.11.3 | Nodeexternalrelays | |||
| 1.3.6.1.4.1.20916.1.11.3.1 | Nodeexternalrelay1 | |||
| 1.3.6.1.4.1.20916.1.11.3.1.1 | Scalarexternalrelay1-element-one | read-write | mandatory | The status of the first element on external relay 1. |
| 1.3.6.1.4.1.20916.1.11.3.1.2 | Scalarexternalrelay1-element-two | read-write | mandatory | The status of the second element on external relay 1. |
| 1.3.6.1.4.1.20916.1.11.3.1.3 | Scalarexternalrelay1-element-three | read-write | mandatory | The status of the third element on external relay 1. |
| 1.3.6.1.4.1.20916.1.11.3.1.4 | Scalarexternalrelay1-element-four | read-write | mandatory | The status of the fourth element on external relay 1. |
| 1.3.6.1.4.1.20916.1.11.3.1.5 | Scalarexternalrelay1-element-five | read-write | mandatory | The status of the fifth element on external relay 1. |
| 1.3.6.1.4.1.20916.1.11.3.1.6 | Scalarexternalrelay1-element-six | read-write | mandatory | The status of the sixth element on external relay 1. |
| 1.3.6.1.4.1.20916.1.11.3.1.7 | Scalarexternalrelay1-element-seven | read-write | mandatory | The status of the seventh element on external relay 1. |
| 1.3.6.1.4.1.20916.1.11.3.1.8 | Scalarexternalrelay1-element-eight | read-write | mandatory | The status of the eighth element on external relay 1 |
| 1.3.6.1.4.1.20916.1.11.3.2 | Nodeexternalrelay2 | |||
| 1.3.6.1.4.1.20916.1.11.3.2.1 | Scalarexternalrelay2-element-one | read-write | mandatory | The status of the first element on external relay 2. |
| 1.3.6.1.4.1.20916.1.11.3.2.2 | Scalarexternalrelay2-element-two | read-write | mandatory | The status of the second element on external relay 2. |
| 1.3.6.1.4.1.20916.1.11.3.2.3 | Scalarexternalrelay2-element-three | read-write | mandatory | The status of the third element on external relay 2. |
| 1.3.6.1.4.1.20916.1.11.3.2.4 | Scalarexternalrelay2-element-four | read-write | mandatory | The status of the fourth element on external relay 2. |
| 1.3.6.1.4.1.20916.1.11.3.2.5 | Scalarexternalrelay2-element-five | read-write | mandatory | The status of the fifth element on external relay 2. |
| 1.3.6.1.4.1.20916.1.11.3.2.6 | Scalarexternalrelay2-element-six | read-write | mandatory | The status of the sixth element on external relay 2. |
| 1.3.6.1.4.1.20916.1.11.3.2.7 | Scalarexternalrelay2-element-seven | read-write | mandatory | The status of the seventh element on external relay 2. |
| 1.3.6.1.4.1.20916.1.11.3.2.8 | Scalarexternalrelay2-element-eight | read-write | mandatory | The status of the eighth element on external relay 2 |