ROOMALERT7E-MIB
49 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | Counter enterprises IpAddress TimeTicks |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20916 | Nodeavtech | |||
| 1.3.6.1.4.1.20916.1 | Nodeproducts | |||
| 1.3.6.1.4.1.20916.1.2 | Noderoomalert7e | |||
| 1.3.6.1.4.1.20916.1.2.1 | Nodealarmstart1-7e | A alarmstart1 trap signifies that the current temperature on sensor 1 is outside the defined high or low threshold. | ||
| 1.3.6.1.4.1.20916.1.2.1 | Nodesensors | |||
| 1.3.6.1.4.1.20916.1.2.1.1 | Nodetemperature | |||
| 1.3.6.1.4.1.20916.1.2.1.1.1 | Scalartempreading1c | read-only | mandatory | Temperature Sensor 1 (Celsius) |
| 1.3.6.1.4.1.20916.1.2.1.1.2 | Scalartempreading2c | read-only | mandatory | Temperature Sensor 2 (Celsius) |
| 1.3.6.1.4.1.20916.1.2.1.1.3 | Scalartempreading3c | read-only | mandatory | Temperature Sensor 3 (Celsius) |
| 1.3.6.1.4.1.20916.1.2.1.1.4 | Scalartempreading4c | read-only | mandatory | Temperature Sensor 4 (Celsius) |
| 1.3.6.1.4.1.20916.1.2.1.1.5 | Scalartempreading1f | read-only | mandatory | Temperature Sensor 1 (Fahrenheit) |
| 1.3.6.1.4.1.20916.1.2.1.1.6 | Scalartempreading2f | read-only | mandatory | Temperature Sensor 2 (Fahrenheit) |
| 1.3.6.1.4.1.20916.1.2.1.1.7 | Scalartempreading3f | read-only | mandatory | Temperature Sensor 3 (Fahrenheit) |
| 1.3.6.1.4.1.20916.1.2.1.1.8 | Scalartempreading4f | read-only | mandatory | Temperature Sensor 4 (Fahrenheit) |
| 1.3.6.1.4.1.20916.1.2.1.2 | Nodeswitch | |||
| 1.3.6.1.4.1.20916.1.2.1.2.1 | Scalarswitch1 | read-only | mandatory | Switch Sensor 1 (0 = OFF, 1 = ON) |
| 1.3.6.1.4.1.20916.1.2.1.2.2 | Scalarswitch2 | read-only | mandatory | Switch Sensor 2 (0 = OFF, 1 = ON) |
| 1.3.6.1.4.1.20916.1.2.1.2.3 | Scalarswitch3 | read-only | mandatory | Switch Sensor 3 (0 = OFF, 1 = ON) |
| 1.3.6.1.4.1.20916.1.2.2 | Noderoom-alert-7e-snmp-trap | A room-alert-7e-snmp-trap indicates that an alarm condition has occurred on the sensor inidcated by the alarmmessage variable. | ||
| 1.3.6.1.4.1.20916.1.2.2 | Nodetraps | |||
| 1.3.6.1.4.1.20916.1.2.2.1 | Scalaralarmtemp1 | read-only | mandatory | Alarm for temperature 1 0 = temperature OK 1 = temperature too high 2 = temperature too low |
| 1.3.6.1.4.1.20916.1.2.2.2 | Scalaralarmtemp2 | read-only | mandatory | Alarm for temperature 2 0 = temperature OK 1 = temperature too high 2 = temperature too low |
| 1.3.6.1.4.1.20916.1.2.2.3 | Scalaralarmtemp3 | read-only | mandatory | Alarm for temperature 3 0 = temperature OK 1 = temperature too high 2 = temperature too low |
| 1.3.6.1.4.1.20916.1.2.2.4 | Scalaralarmtemp4 | read-only | mandatory | Alarm for temperature 4 0 = temperature OK 1 = temperature too high 2 = temperature too low |
| 1.3.6.1.4.1.20916.1.2.2.5 | Scalaralarmswitch1 | read-only | mandatory | Alarm for switch sensor 1 0 = Switch Open 1 = Switch Closed |
| 1.3.6.1.4.1.20916.1.2.2.6 | Scalaralarmswitch2 | read-only | mandatory | Alarm for switch sensor 2 0 = Switch Open 1 = Switch Closed |
| 1.3.6.1.4.1.20916.1.2.2.7 | Scalaralarmswitch3 | read-only | mandatory | Alarm for switch sensor 3 0 = Switch Open 1 = Switch Closed |
| 1.3.6.1.4.1.20916.1.2.2.8 | Scalaralarmmessage | read-write | mandatory | Message string to send with trap messages |
| 1.3.6.1.4.1.20916.1.2.3 | Nodealarmstart2-7e | A alarmstart2 trap signifies that the current temperature on sensor 2 is outside the defined high or low threshold. | ||
| 1.3.6.1.4.1.20916.1.2.3 | Nodethresholds | |||
| 1.3.6.1.4.1.20916.1.2.3.1 | Scalarupperlimit1 | read-only | mandatory | High temperature threshold for temperature sensor 1 |
| 1.3.6.1.4.1.20916.1.2.3.2 | Scalarlowerlimit1 | read-only | mandatory | Low temperature threshold for temperature sensor 1 |
| 1.3.6.1.4.1.20916.1.2.3.3 | Scalarupperlimit2 | read-only | mandatory | High temperature threshold for temperature sensor 2 |
| 1.3.6.1.4.1.20916.1.2.3.4 | Scalarlowerlimit2 | read-only | mandatory | Low temperature threshold for temperature sensor 2 |
| 1.3.6.1.4.1.20916.1.2.3.5 | Scalarupperlimit3 | read-only | mandatory | High temperature threshold for temperature sensor 3 |
| 1.3.6.1.4.1.20916.1.2.3.6 | Scalarlowerlimit3 | read-only | mandatory | Low temperature threshold for temperature sensor 3 |
| 1.3.6.1.4.1.20916.1.2.3.7 | Scalarupperlimit4 | read-only | mandatory | High temperature threshold for temperature sensor 4 |
| 1.3.6.1.4.1.20916.1.2.3.8 | Scalarlowerlimit4 | read-only | mandatory | Low temperature threshold for temperature sensor 4 |
| 1.3.6.1.4.1.20916.1.2.4 | Nodealarmclear2-7e | A alarmclear2 trap signifies that the current temperature on sensor 2 has returned to a normal condition and is within the defined high or low threshold. | ||
| 1.3.6.1.4.1.20916.1.2.5 | Nodealarmstart3-7e | A alarmstart3 trap signifies that the current temperature on sensor 3 is outside the defined high or low threshold. | ||
| 1.3.6.1.4.1.20916.1.2.6 | Nodealarmclear3-7e | A alarmclear3 trap signifies that the current temperature on sensor 3 has returned to a normal condition and is within the defined high or low threshold. | ||
| 1.3.6.1.4.1.20916.1.2.7 | Nodealarmstart4-7e | A alarmstart4 trap signifies that the current temperature on sensor 4 is outside the defined high or low threshold. | ||
| 1.3.6.1.4.1.20916.1.2.8 | Nodealarmclear4-7e | A alarmclear4 trap signifies that the current temperature on sensor 4 has returned to a normal condition and is within the defined high or low threshold. | ||
| 1.3.6.1.4.1.20916.1.2.9 | Nodealarmstart5-7e | A alarmstart5 trap signifies that the current status of switch sensor 1 is outside the defined threshold. | ||
| 1.3.6.1.4.1.20916.1.2.10 | Nodealarmclear5-7e | A alarmclear5 trap signifies that the current status of switch sensor 1 is outside the defined threshold. | ||
| 1.3.6.1.4.1.20916.1.2.11 | Nodealarmstart6-7e | A alarmstart6 trap signifies that the current status of switch sensor 2 is outside the defined threshold. | ||
| 1.3.6.1.4.1.20916.1.2.12 | Nodealarmclear6-7e | A alarmclear6 trap signifies that the current status of switch sensor 2 is outside the defined threshold. | ||
| 1.3.6.1.4.1.20916.1.2.13 | Nodealarmstart7-7e | A alarmstart7 trap signifies that the current status of switch sensor 3 is outside the defined threshold. | ||
| 1.3.6.1.4.1.20916.1.2.14 | Nodealarmclear7-7e | A alarmclear7 trap signifies that the current status of switch sensor 3 is outside the defined threshold. |