ROOMALERTST4E-MIB
36 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | Counter enterprises IpAddress TimeTicks |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20916 | Nodeavtech | |||
| 1.3.6.1.4.1.20916.1 | Nodeproducts | |||
| 1.3.6.1.4.1.20916.1.6 | NodeROOMALERTST4E | |||
| 1.3.6.1.4.1.20916.1.6.1 | Nodesensors | |||
| 1.3.6.1.4.1.20916.1.6.1.1 | Nodeinternal | |||
| 1.3.6.1.4.1.20916.1.6.1.1.1 | Nodetemperature | |||
| 1.3.6.1.4.1.20916.1.6.1.1.1.1 | Scalarinternal-tempf | read-only | mandatory | The internal temperature reading in Fahrenheit. Because the SNMP Protocol does not support floating point numbers, values are scaled by 100 and should be divid… |
| 1.3.6.1.4.1.20916.1.6.1.1.1.2 | Scalarinternal-tempc | read-only | mandatory | The internal temperature reading in Celsius. Because the SNMP Protocol does not support floating point numbers, values are scaled by 100 and should be divided … |
| 1.3.6.1.4.1.20916.1.6.1.1.2 | Nodehumidity | |||
| 1.3.6.1.4.1.20916.1.6.1.1.2.1 | Scalarinternal-humidity | read-only | mandatory | The internal relative humidity reading in %RH. Because the SNMP Protocol does not support floating point numbers, values are scaled by 100 and should be divide… |
| 1.3.6.1.4.1.20916.1.6.1.1.3 | Nodeheat-index | |||
| 1.3.6.1.4.1.20916.1.6.1.1.3.1 | Scalarinternal-heat-index | read-only | mandatory | The internal heat index reading in Fahrenheit. Because the SNMP Protocol does not support floating point numbers, values are scaled by 100 and should be divide… |
| 1.3.6.1.4.1.20916.1.6.1.2 | Nodedigital | |||
| 1.3.6.1.4.1.20916.1.6.1.2.1 | Nodedigital-sen1 | |||
| 1.3.6.1.4.1.20916.1.6.1.2.1.1 | Scalardigital-sen1-1 | read-only | mandatory | If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Celsius. If this sensor is a Digital Power Sensor, th… |
| 1.3.6.1.4.1.20916.1.6.1.2.1.2 | Scalardigital-sen1-2 | read-only | mandatory | If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Fahrenheit. If this sensor is a Digital Power Sensor,… |
| 1.3.6.1.4.1.20916.1.6.1.2.1.3 | Scalardigital-sen1-3 | read-only | mandatory | If this sensor is a Temp/Humidity sensor, this value represents the current relative humidity in % Relative Humidity. If this sensor is a Digital Power Sensor,… |
| 1.3.6.1.4.1.20916.1.6.1.2.1.4 | Scalardigital-sen1-4 | read-only | mandatory | If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current heat index in Fahrenheit. If this sensor is a Digital Power Sensor, … |
| 1.3.6.1.4.1.20916.1.6.1.2.2 | Nodedigital-sen2 | |||
| 1.3.6.1.4.1.20916.1.6.1.2.2.1 | Scalardigital-sen2-1 | read-only | mandatory | If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Celsius. If this sensor is a Digital Power Sensor, th… |
| 1.3.6.1.4.1.20916.1.6.1.2.2.2 | Scalardigital-sen2-2 | read-only | mandatory | If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Fahrenheit. If this sensor is a Digital Power Sensor,… |
| 1.3.6.1.4.1.20916.1.6.1.2.2.3 | Scalardigital-sen2-3 | read-only | mandatory | If this sensor is a Temp/Humidity sensor, this value represents the current relative humidity in % Relative Humidity. If this sensor is a Digital Power Sensor,… |
| 1.3.6.1.4.1.20916.1.6.1.2.2.4 | Scalardigital-sen2-4 | read-only | mandatory | If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current heat index in Fahrenheit. If this sensor is a Digital Power Sensor, … |
| 1.3.6.1.4.1.20916.1.6.1.3 | Nodeswitch | |||
| 1.3.6.1.4.1.20916.1.6.1.3.1 | Scalarswitch-sen1 | read-only | mandatory | The reading for switch sensor 1 (0 = OPEN, 1 = CLOSED). |
| 1.3.6.1.4.1.20916.1.6.2 | Noderoom-alert-st4e-snmp-trap | A room-alert-st4e-snmp-trap indicates that an alarm condition has occurred on the sensor indicated by the alarmmessage variable. | ||
| 1.3.6.1.4.1.20916.1.6.2 | Nodesignaltower | |||
| 1.3.6.1.4.1.20916.1.6.2.1 | Scalarred-led | read-write | current | The status of this Signal Tower element (0 = OFF, 1 = ON). |
| 1.3.6.1.4.1.20916.1.6.2.2 | Scalaramber-led | read-write | current | The status of this Signal Tower element (0 = OFF, 1 = ON). |
| 1.3.6.1.4.1.20916.1.6.2.3 | Scalargreen-led | read-write | current | The status of this Signal Tower element (0 = OFF, 1 = ON). |
| 1.3.6.1.4.1.20916.1.6.2.4 | Scalarblue-led | read-write | current | The status of this Signal Tower element (0 = OFF, 1 = ON). |
| 1.3.6.1.4.1.20916.1.6.2.5 | Scalarwhite-led | read-write | current | The status of this Signal Tower element (0 = OFF, 1 = ON). |
| 1.3.6.1.4.1.20916.1.6.2.6 | Scalaralarm1 | read-write | current | The status of this Signal Tower element (0 = OFF, 1 = ON). |
| 1.3.6.1.4.1.20916.1.6.2.7 | Scalaralarm2 | read-write | current | The status of this Signal Tower element (0 = OFF, 1 = ON). |
| 1.3.6.1.4.1.20916.1.6.3 | Nodetraps | |||
| 1.3.6.1.4.1.20916.1.6.3.1 | Scalaralarmmessage | read-only | mandatory | Last Alarm Message |