MIB Viewer

SAVEPOWER-MIB

46 objects
The MIB module is for saving power in blocks that control the physical ports.
Imported Objects
ENTITY-MIBentPhysicalIndex
HP-ICF-OIDhpSwitch
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMIMODULE-IDENTITY OBJECT-TYPE Unsigned32
SNMPv2-TCDateAndTime DisplayString TEXTUAL-CONVENTION TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.11.2.14.11.5.1.56IdentityhpicfSavepowerMIBThe MIB module is for saving power in blocks that control the physical ports.
1.3.6.1.4.1.11.2.14.11.5.1.56.1NodehpicfSavepowerScalars
1.3.6.1.4.1.11.2.14.11.5.1.56.1.1ScalarhpicfSavepowerMaxBlocksread-onlycurrentThe maximum number of Power blocks in the switch which are associated to a group of ports to power on/off. The number of power blocks and ports associated with…
1.3.6.1.4.1.11.2.14.11.5.1.56.1.2ScalarhpicfSavepowerEnabledPortsread-onlycurrentThis indicates the total number of ports in the switch that are powered off.
1.3.6.1.4.1.11.2.14.11.5.1.56.1.3NodehpicfSavepowerLEDScalars
1.3.6.1.4.1.11.2.14.11.5.1.56.1.3.1ScalarhpicfSavePowerLEDOffAlarmStartTimeread-writecurrentThis is the scheduled time at which the all the switch LEDs would be turned off.
1.3.6.1.4.1.11.2.14.11.5.1.56.1.3.2ScalarhpicfSavePowerLEDOffAlarmDurationread-writecurrentThis is the duration of the alarm time during which the switch would be in LED power save mode, and the switch LEDs would be turned off.
1.3.6.1.4.1.11.2.14.11.5.1.56.1.3.3ScalarhpicfSavePowerLEDOffAlarmRecurread-writecurrentThe truth value used to indicate if the timer for LED off will be recurring.
1.3.6.1.4.1.11.2.14.11.5.1.56.2NodehpicfEntitySavepower
1.3.6.1.4.1.11.2.14.11.5.1.56.2.1TablehpicfSavepowerTablenot-accessiblecurrentThis table contains one row for every power block that controls a group of physical ports.
1.3.6.1.4.1.11.2.14.11.5.1.56.2.1.1RowhpicfSavepowerEntrynot-accessiblecurrentInformation about Savepower table.
1.3.6.1.4.1.11.2.14.11.5.1.56.2.1.1.1ColumnhpicfSavepowerBlockIDnot-accessiblecurrentThe index that is used to access the power block entry table.
1.3.6.1.4.1.11.2.14.11.5.1.56.2.1.1.2ColumnhpicfSavepowerControlread-writecurrentThis indicates if the power to the block is powerOn (1) or powerOff (2).
1.3.6.1.4.1.11.2.14.11.5.1.56.2.1.1.3ColumnhpicfSavepowerBlockPortsread-onlycurrentThis indicates the port-range associated to the hpisfSavepowerBlockID.
1.3.6.1.4.1.11.2.14.11.5.1.56.2.2TablehpicfSavepowerGreenFeaturesTablenot-accessiblecurrentThis table contains a row for different entities and shows the admin status and operational status of the power and LED for that entity.
1.3.6.1.4.1.11.2.14.11.5.1.56.2.2.1RowhpicfSavepowerGreenFeaturesEntrynot-accessiblecurrentInformation about SavepowerGreenFeatures table.
1.3.6.1.4.1.11.2.14.11.5.1.56.2.2.1.1ColumnhpicfSavepowerEntityPowerAdminStatusread-writecurrentThe truth value indicates the configured status of the entity power.
1.3.6.1.4.1.11.2.14.11.5.1.56.2.2.1.2ColumnhpicfSavepowerEntityPowerOperStatusread-onlycurrentThis indicates the operational status of the entity as powerOn(1) if turned on or powerOff(2) if turned off.
1.3.6.1.4.1.11.2.14.11.5.1.56.2.2.1.3ColumnhpicfSavepowerEntityLEDAdminStatusread-writecurrentThe truth value indicates the configured status of the entity's LED power status.
1.3.6.1.4.1.11.2.14.11.5.1.56.2.2.1.4ColumnhpicfSavepowerEntityLEDOperStatusread-onlycurrentThis indicates if the operational status of the entity's LED power is powerOn (1) or powerOff (2).
1.3.6.1.4.1.11.2.14.11.5.1.56.2.3TablehpicfSavepowerPHYTablenot-accessiblecurrentThis table contains a row for every port for which the PHY will be put to auto low power mode or normal power mode and contains the admin status and operationa…
1.3.6.1.4.1.11.2.14.11.5.1.56.2.3.1RowhpicfSavepowerPHYEntrynot-accessiblecurrentInformation about PHY power status for ports.
1.3.6.1.4.1.11.2.14.11.5.1.56.2.3.1.1ColumnhpicfSavepowerSlotNumnot-accessiblecurrentThis value serves as an index to identify the slot no. for the PHY.
1.3.6.1.4.1.11.2.14.11.5.1.56.2.3.1.2ColumnhpicfSavepowerPortNumnot-accessiblecurrentThis value serves as an index to identify the port no. for the PHY.
1.3.6.1.4.1.11.2.14.11.5.1.56.2.3.1.3ColumnhpicfSavepowerPHYAdminStatusread-writecurrentThe truth value indicates the configured status of the auto low power mode for the PHY.
1.3.6.1.4.1.11.2.14.11.5.1.56.2.3.1.4ColumnhpicfSavepowerPHYOperStatusread-onlycurrentThis indicates if the operational status of the PHY power is auto low power mode i.e. powerOff(2) or normal power mode i.e. or powerOn(1).
1.3.6.1.4.1.11.2.14.11.5.1.56.2.4TablehpicfSavepowerEntPHYTablenot-accessiblecurrentThis table contains a row for every member in a stack setup or for a standalone device or for every slot in a chassis, for which the PHY will be put to auto lo…
1.3.6.1.4.1.11.2.14.11.5.1.56.2.4.1RowhpicfSavepowerEntPHYEntrynot-accessiblecurrentInformation about PHY power status.
1.3.6.1.4.1.11.2.14.11.5.1.56.2.4.1.1ColumnhpicfSavepowerEntPHYAdminStatusread-writecurrentThe truth value indicates the configured status of the auto low power mode for the PHY. True indicates PHY is in low power mode.
1.3.6.1.4.1.11.2.14.11.5.1.56.2.4.1.2ColumnhpicfSavepowerEntPHYOperStatusread-onlycurrentThis indicates if the operational status of the PHY power is auto low power mode i.e. powerOff(2) or normal power mode i.e. powerOn(1).
1.3.6.1.4.1.11.2.14.11.5.1.56.3NodehpicfSavepowerConformance
1.3.6.1.4.1.11.2.14.11.5.1.56.3.1NodehpicfSavepowerCompliance
1.3.6.1.4.1.11.2.14.11.5.1.56.3.1.1CompliancehpicfSavepowerComplianceInfocurrentThe compliance statement for entries which implement the SAVEPOWER MIB.
1.3.6.1.4.1.11.2.14.11.5.1.56.3.2NodehpicfSavepowerGroups
1.3.6.1.4.1.11.2.14.11.5.1.56.3.2.1GrouphpicfSavepowerScalarsGroupcurrentBasic Scalars required in SAVEPOWER MIB implementation.
1.3.6.1.4.1.11.2.14.11.5.1.56.3.2.2GrouphpicfSavepowerLEDScalarsGroupcurrentScalars required for LED turn off feature.
1.3.6.1.4.1.11.2.14.11.5.1.56.3.2.3GrouphpicfSavepowerGreenFeaturesGroupcurrentSAVEPOWER Green Features parameters
1.3.6.1.4.1.11.2.14.11.5.1.56.3.2.4GrouphpicfSavepowerPHYGroupcurrentSAVEPOWER MIB parameters
1.3.6.1.4.1.11.2.14.11.5.1.56.3.2.5GrouphpicfSavepowerGroupcurrentSAVEPOWER MIB parameters
1.3.6.1.4.1.11.2.14.11.5.1.56.4NodehpicfPHYConformance
1.3.6.1.4.1.11.2.14.11.5.1.56.4.1NodehpicfPHYCompliance
1.3.6.1.4.1.11.2.14.11.5.1.56.4.1.1CompliancehpicfPHYComplianceInfocurrentThe compliance statement for entries which implement the PORT LOW POWER.
1.3.6.1.4.1.11.2.14.11.5.1.56.4.2NodehpicfPHYGroups
1.3.6.1.4.1.11.2.14.11.5.1.56.4.2.1GrouphpicfSavepowerEntPHYGroupcurrentPORT-LOW-POWER MIB parameters
Type Definitions
NameSyntaxStatusDescription
SavepowerBlockIndexUnsigned32currentA unique value that serves as an index to identify the Power block ID that controls power distribution to a group of ports associated with the block-id.
SavepowerControlINTEGER { powerOn(1), powerOff(2) }currentAn enumerated value which provides an indication of the state of the power block. If power to the block is ON the state would be powerOn and if power to the block is OFF the state would be powerOff.