MIB Viewer

SCTE-HMS-COMMON-MIB

46 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212OBJECT-TYPE
RFC-1215TRAP-TYPE
RFC1155-SMICounter NetworkAddress
RFC1213-MIBDisplayString
SCTE-HMS-ROOTScommonIdent
SCTE-ROOTscteHmsTree
OIDNameAccessStatusDescription
1.3.6.1.4.1.5591.1.0NodehmsColdStartA hmsColdStart trap signifies that the sending protocol entity is reinitializing itself such that the agent's configuration or the protocol entity implementati…
1.3.6.1.4.1.5591.1.2NodehmsWarmStartA hmsWarmStart trap signifies that the sending protocol entity is reinitializing itself such that neither the agent's configuration nor the protocol entity imp…
1.3.6.1.4.1.5591.1.3.1NodecommonAdminGroup
1.3.6.1.4.1.5591.1.3.1.1ScalarcommonLogicalIDread-writemandatorySpecifies the logical ID for the network element used by network management systems. The ID will often remain with a specific location regardless of any specif…
1.3.6.1.4.1.5591.1.3.1.2ScalarcommonVendorread-onlymandatoryDisplays the manufacturer of the network element. Displayed in human-readable format.
1.3.6.1.4.1.5591.1.3.1.3ScalarcommonModelNumberread-onlymandatoryDisplays the model number of the network element. Displayed in human-readable format.
1.3.6.1.4.1.5591.1.3.1.4ScalarcommonSerialNumberread-onlymandatoryReturns the Serial Number of the Network Element. Displayed in human-readable format.
1.3.6.1.4.1.5591.1.3.1.5ScalarcommonVendorInforead-onlyoptionalReturns vendor-specific information. Displayed in human-readable format.
1.3.6.1.4.1.5591.1.3.1.6ScalarcommonNEStatusread-onlymandatoryBit mask, identical to that used in the Status field of the STATRESP PDU. See SCTE 25-2 (formerly HMS004). Bit 0: CHNLRQST Bit 1: CNTNRM Bit 2: CNTCUR Bit 3: M…
1.3.6.1.4.1.5591.1.3.1.7ScalarcommonResetread-writemandatoryThis object is used to reset the NE by writing 1 to it. Other values written to the object have no effect. Reading the object returns a 1, and has no effect on…
1.3.6.1.4.1.5591.1.3.1.8ScalarcommonAlarmDetectionControlread-writemandatoryThis object is used to control the detection of alarms in this NE. When a threshold from either the property table or the discrete property table is crossed in…
1.3.6.1.4.1.5591.1.3.1.9ScalarcommonNetworkAddressread-onlymandatoryThis variable reports the network address (e.g., IP address) of the NE. This object was added to support the generation of traps. The value is retained in non-…
1.3.6.1.4.1.5591.1.3.1.10ScalarcommonCheckCoderead-writemandatoryThis object reports the Check Code for the transponder's configuration. The check code is generated from objects which are stored in non-volatile memory as wel…
1.3.6.1.4.1.5591.1.3.1.11ScalarcommonTrapCommunityStringread-writemandatoryThis object defines the community string reported in a trap. The default value is 'public'. Use of this object does not preclude the use of enterprise specific…
1.3.6.1.4.1.5591.1.3.1.12ScalarcommonTamperStatusread-onlyoptionalReturns the status of the anti-tamper device of the network element. this object requires an entry in the Discrete Property Table. the intact(1) value represen…
1.3.6.1.4.1.5591.1.3.1.13ScalarcommonInternalTemperatureread-onlyoptionalMeasured temperature inside the NE's case/housing. Units degrees Celsius. This item requires an entry in the properties MIB
1.3.6.1.4.1.5591.1.3.1.14ScalarcommonTimeread-onlyoptionalAll values are unsigned 32 bit integers. Time since the Epoch (00:00:00 UTC, January 1, 1970), measured in seconds(POSIX).
1.3.6.1.4.1.5591.1.3.1.15ScalarcommonVarBindingsread-onlymandatoryThis object indicates the maximum number of entries in the variable-binding list which can be accepted by the unit. A value of 0 indicates no specified limit.
1.3.6.1.4.1.5591.1.3.1.16ScalarcommonResetCauseread-onlymandatoryThis object reports the cause of the last reset.
1.3.6.1.4.1.5591.1.3.1.17ScalarcommonCraftStatusread-onlymandatoryThis object reports the state of the craft interface. The status of this object does not imply any change to the transponder functionality through the MAC inte…
1.3.6.1.4.1.5591.1.3.2NodecommonMACGroup
1.3.6.1.4.1.5591.1.3.2.1ScalarcommonBackoffPeriodread-writemandatoryThe backoff period in millseconds. This parameter is used as part of the random backoff period as defined by the Media Access Control Layer specification SCTE …
1.3.6.1.4.1.5591.1.3.2.2ScalarcommonACKTimeoutWindowread-writemandatoryThe Acknowledgement timeout window in milliseconds. Initial Power up default: 19 milliseconds. The value for this object is maintained in non-volatile memory.
1.3.6.1.4.1.5591.1.3.2.3ScalarcommonMaximumMACLayerRetriesread-writemandatoryThe maximum number of retries a NE can make for a specific packet. This limit is intended to protect the network from a unit with a faulty receiver. Initial Po…
1.3.6.1.4.1.5591.1.3.2.4ScalarcommonMaxPayloadSizeread-onlymandatoryThis object reports the maximum length of the payload supported for a packet on the reverse or forward channel.
1.3.6.1.4.1.5591.1.3.2.5ScalarcommonBackoffMinimumExponentread-writemandatoryThis object is used to define the minimum value of the exponent used for the Backoff Algorithm as defined by the Media Access Control Layer specification SCTE …
1.3.6.1.4.1.5591.1.3.2.6ScalarcommonBackoffMaximumExponentread-writemandatoryThis object is used to define the maximum value of the exponent used for the Backoff Algorithm as defined by the Media Access Control Layer specification SCTE …
1.3.6.1.4.1.5591.1.3.2.7ScalarcommonPhysAddressread-onlymandatoryThis variable reports the media dependant 'physical' address of the NE. This object was added to support the generation of traps.
1.3.6.1.4.1.5591.1.3.3NodecommonMulticastGroup
1.3.6.1.4.1.5591.1.3.3.1ScalarcommonMaxMulticastAddressesread-onlymandatoryMaximum number of multicast data link layer addresses supported by this NE.
1.3.6.1.4.1.5591.1.3.3.2TablecommonMulticastAddressTablenot-accessiblemandatoryThe table containing the multicast addresses. The value for all objects in this table are maintained in non-volatile memory.
1.3.6.1.4.1.5591.1.3.3.2.1RowcommonMulticastAddressEntrynot-accessiblemandatoryA list of information for multicast addresses.
1.3.6.1.4.1.5591.1.3.3.2.1.1ColumncommonMulticastAddressIndexread-onlymandatoryIndex into commonMulticastAddressTable.
1.3.6.1.4.1.5591.1.3.3.2.1.2ColumncommonMulticastAddressNumberread-writemandatoryThe multicast address. Only entries with the I/G bit set are accepted values. An empty entry is designated by setting the object to the broadcast address.
1.3.6.1.4.1.5591.1.3.4NodecommonStatsGroup
1.3.6.1.4.1.5591.1.3.4.1NodecommonMacStats
1.3.6.1.4.1.5591.1.3.4.1.1ScalarcommonForwardPathLOSEventsread-writeoptionalCount of forward path loss of signal (LOS) events. Can be reset to 0.
1.3.6.1.4.1.5591.1.3.4.1.2ScalarcommonForwardPathFramingErrorsread-writeoptionalCount of framing errors on the forward path. Can be reset to 0.
1.3.6.1.4.1.5591.1.3.4.1.3ScalarcommonForwardPathCRCErrorsread-writeoptionalCount of CRC errors on the forward path. Can be reset to 0.
1.3.6.1.4.1.5591.1.3.4.1.4ScalarcommonInvalidMacCmdsread-writeoptionalCount of invalid MAC commands. Can be reset to 0.
1.3.6.1.4.1.5591.1.3.5NodecommonRfGroup
1.3.6.1.4.1.5591.1.3.5.1ScalarcommonReturnPathFrequencyread-onlymandatoryReturn path frequency. Units 1 Hz. The value for this object is maintained in non-volatile memory.
1.3.6.1.4.1.5591.1.3.5.2ScalarcommonForwardPathFrequencyread-onlymandatoryForward path frequency. Units 1 Hz. The value for this object is maintained in non-volatile memory.
1.3.6.1.4.1.5591.1.3.5.3ScalarcommonProvisionedReturnPowerLevelread-writemandatoryReturn path power level to be used. Units 0.1 dBmV. The value used internally will be rounded to the nearest supported value. The object reports the requested …
1.3.6.1.4.1.5591.1.3.5.4ScalarcommonForwardPathReceiveLevelread-onlyoptionalReturns the received forward path power level. Units 0.1 dBmV.
1.3.6.1.4.1.5591.1.3.5.5ScalarcommonMaxReturnPowerread-writemandatoryThe maximum return path power to be used by the NE. Units 0.1 dBmV. The value for this object is maintained in non-volatile memory.