MIB Viewer

SCTE-HMS-GEN-MIB

32 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212OBJECT-TYPE
SCTE-HMS-ROOTSgenIdent
OIDNameAccessStatusDescription
1.3.6.1.4.1.5591.1.6.1ScalargenNumberOfGeneratorsread-onlymandatoryNumber of generators connected to this NE.
1.3.6.1.4.1.5591.1.6.2TablegenDeviceTablenot-accessiblemandatoryTable containing information about the individual generators being monitored
1.3.6.1.4.1.5591.1.6.2.1RowgenDeviceEntrynot-accessiblemandatoryList of information about each generator being monitored.
1.3.6.1.4.1.5591.1.6.2.1.1ColumngenDeviceAddressread-onlymandatoryIndex into the psDeviceTable. Address of Generator on the RS-485 Path
1.3.6.1.4.1.5591.1.6.2.1.2ColumngenProtocolVersionread-onlymandatoryVersion of the SCTE HMS protocol implemented in the monitored equipment. The 'Protocol Version' implementation will comply with the defined protocol in the SCT…
1.3.6.1.4.1.5591.1.6.2.1.3ColumngenSoftwareVersionread-onlymandatoryThe contents of this field are vendor specific. The intent is to provide a text representation of the power supply or generator system software version. Any pr…
1.3.6.1.4.1.5591.1.6.2.1.4ColumngenDeviceIdread-onlymandatoryThe content of this field is vendor specific. The intent is to provide manufacturer and/or product specific ASCII text information that will propagate to the m…
1.3.6.1.4.1.5591.1.6.2.1.5ColumngenGasHazardOptionread-onlymandatoryDefines if gas hazard sensor is installed.
1.3.6.1.4.1.5591.1.6.2.1.6ColumngenWaterIntrusionOptionread-onlymandatoryDefines if water intrusion sensor is installed.
1.3.6.1.4.1.5591.1.6.2.1.7ColumngenPadShearOptionread-onlymandatoryDefines if pad shear sensor is installed.
1.3.6.1.4.1.5591.1.6.2.1.8ColumngenDoorOptionread-onlymandatoryDefines if separate generator door is installed.
1.3.6.1.4.1.5591.1.6.2.1.9ColumngenChargerOptionread-onlymandatoryDefines if charger fail signal is supported.
1.3.6.1.4.1.5591.1.6.2.1.10ColumngenFuelOptionread-onlymandatoryDefines if low fuel detection is supported.
1.3.6.1.4.1.5591.1.6.2.1.11ColumngenVBatIgnitionOptionread-onlymandatoryDefines if engine ignition battery voltage is monitored.
1.3.6.1.4.1.5591.1.6.2.1.12ColumngenTempOptionread-onlymandatoryDefines if engine enclosure temperature is monitored.
1.3.6.1.4.1.5591.1.6.2.1.13ColumngenGeneratorStatusread-onlymandatoryDefines the current state of generator operation. 1 = Off 2 = Running(test) 3 = Running 4 = Fail (A condition preventing the generator from functioning) This i…
1.3.6.1.4.1.5591.1.6.2.1.14ColumngenGasHazardread-onlymandatoryThe concentration of hydrocarbon fuel in the generator enclosure has exceeded safe limits. Generator operation is suspended. The alarm is cleared when the sens…
1.3.6.1.4.1.5591.1.6.2.1.15ColumngenWaterIntrusionread-onlymandatoryWater level within the generator or fuel enclosure has exceeded safe limits for generator operation. Generator operation is suspended while this alarm is activ…
1.3.6.1.4.1.5591.1.6.2.1.16ColumngenPadShearread-onlymandatoryIndicates that the generator or fuel enclosure has shifted from its mounting position. Generator operation is suspended. The alarm is reset when the unit its r…
1.3.6.1.4.1.5591.1.6.2.1.17ColumngenEnclosureDoorread-onlymandatoryIndicates current status of the generator and/or auxiliary fuel enclosure door. This item requires entries in the discrete property table.
1.3.6.1.4.1.5591.1.6.2.1.18ColumngenChargerread-onlymandatoryIndicates if the ignition battery charger is operating. This item requires entries in the discrete property table.
1.3.6.1.4.1.5591.1.6.2.1.19ColumngenFuelread-onlymandatoryIndicates if the engine's fuel supply is sufficient for extended operation. Alarm is reset when fuel is replenished. This item requires entries in the discrete…
1.3.6.1.4.1.5591.1.6.2.1.20ColumngenVBatIgnitionread-onlymandatoryScaled representation of the generator's ignition battery in 1/100 Volts. This item requires an entry in the property table.
1.3.6.1.4.1.5591.1.6.2.1.21ColumngenEnclosureTemperatureread-onlymandatoryTemperature inside generator's enclosure in degrees C. This item requires an entry in the property table.
1.3.6.1.4.1.5591.1.6.2.1.22ColumngenEquipmentControlread-writeoptionalWhen written, the appropriate corresponding command action is sent to the generator. 1 = End generator test 2 = Start generator test 3 = Reset latched generato…
1.3.6.1.4.1.5591.1.6.2.1.23ColumngenOilOptionread-onlymandatoryDefines if oil pressure is monitored.
1.3.6.1.4.1.5591.1.6.2.1.24ColumngenMinorAlarmSupportread-onlymandatoryDefines if the minor alarm indicator is supported.
1.3.6.1.4.1.5591.1.6.2.1.25ColumngenMajorAlarmSupportread-onlymandatoryDefines if the major alarm indicator is supported.
1.3.6.1.4.1.5591.1.6.2.1.26ColumngenOilread-onlyoptionalIndicates if the engine's oil is adequate for safe operation. Alarm is reset when the condition returns to normal. This item requires entries in the discrete p…
1.3.6.1.4.1.5591.1.6.2.1.27ColumngenMinorAlarmread-onlyoptionalIndicates if the generator is indicating a minor alarm. The generator requires attention, but does not require an immediate visit to the generator. This item r…
1.3.6.1.4.1.5591.1.6.2.1.28ColumngenMajorAlarmread-onlyoptionalIndicates if the generator is indicating a major alarm. The generator requires immediate attention, and should be visited immediately to remedy the situation. …
1.3.6.1.4.1.5591.1.6.2.1.29ColumngenVendorOIDread-onlyoptionalThis object provides a means for a vendor to point to a vendor specific extension of this MIB.