SCTE-HMS-HEADENDIDENT-TC-MIB

14 objects
No module-level DESCRIPTION found.
Imported Objects
SNMPv2-SMIenterprises Integer32 MODULE-IDENTITY Unsigned32
SNMPv2-TCTEXTUAL-CONVENTION
Type Definitions
NameSyntaxStatusDescription
HeAlarmControlINTEGER { alarmEnabled(1), alarmDisabled(2) }currentAlarm Control value for a specific device. This object is used to control sending traps related to this headend entity or enabling disabling of raising an alarm condition for a specific entity.
HeDigitalAlarmSeverityINTEGER { critical(1), major(2), minor(3), warning(4), status(5), clear(6), information(7) }currentThe alarm severity that is determined by the device and sent over in the trap message.
HeDigitalAlarmTypeINTEGER { communication(1), process(2), session(3), capacity(4), maintenance(5), provisioning(6), programMgmt(7), redundancy(8), other(9) }currentThe alarm type that describes the Event that caused the alarm.
HeFaultStatusINTEGER { normal(1), fault(2) }currentAn enumerated value that provides a fault status of a particular hardware or software parameter that usually represent some sort of condition. A value normal(1) indicates the normal condition. A value fault(2) indicates…
HeHundredthNanoMeterUnsigned32currentThis data type represents wavelength values that are normally expressed in nano meters. Units are in hundredths of a NanoMeter; for example, 1550.56 nm will be represented as 155056.
HeHundredthWattsUnsigned32currentThis data type represents power values that are normally expressed in watts. Units are in hundredths of a watt; for example, 420 watts will be represented as 42000.
HeMilliAmpUnsigned32currentThis data type represents current levels that are normally expressed in amperes. Units are in milliamperes; for example, 2.1 Amperes would be expressed as 2100.
HeOnOffControlINTEGER { off(1), on(2), meaningless(3) }currentAn enumerated value that provides a control of a particular hardware or software parameter that usually represent some sort of switch. A SET request with a value off(1) will cause the switch to be shut off. A SET reques…
HeOnOffStatusINTEGER { off(1), on(2) }currentAn enumerated value that provides a status of a particular hardware or software parameter that usually represent some sort of switch. A value off(1) indicates the switch is off. A value on(2) indicates the switch is on.
HeTenthCentigradeInteger32currentThis data type represents temperature values that are normally expressed in Centigrade. Units are in tenths of a Centigrade; for example, -5.1 Centigrade will be represented as -51.
HeTenthdBInteger32currentThis data type represents power levels that are normally expressed in dB. Units are in tenths of a dB; for example, -5.1 dB will be represented as -51.
HeTenthdBmInteger32currentThis data type represents power levels that are normally expressed in dBm. Units are in tenths of a dBm; for example, -5.1 dBm will be represented as -51.
HeTenthdBmVInteger32currentThis data type represents power levels that are normally expressed in dBmV. Units are in tenths of a dBmV; for example, -5.1 dBmV will be represented as -51.
HeTrapRegenerateINTEGER { trapRegenerate(1), trapNormal(2) }currentThis value tells the SNMP Agent to send the Trap Regenerate Trap for all values of Current alarms for this entity. The device can provide for a means to send ALL current alarms, not just one specific entity.