MIB Viewer

SDS-MACRO-ST-MIB

222 objects
The MIB module to describe generic objects for AN-D.cz device - SDS MACRO ST.
Imported Objects
SNMPv2-SMICounter32 enterprises Gauge32 Integer32 IpAddress MODULE-IDENTITY OBJECT-TYPE TimeTicks
OIDNameAccessStatusDescription
1.3.6.1.4.1.33283Identitymib-AN-Dcz-SDSThe MIB module to describe generic objects for AN-D.cz device - SDS MACRO ST.
1.3.6.1.4.1.33283.1Nodesdsxpublic
1.3.6.1.4.1.33283.1.55NodesdsMACROST
1.3.6.1.4.1.33283.1.55.1NodesdsIPWatchdog
1.3.6.1.4.1.33283.1.55.1.1ScalaripwActiveread-onlycurrentThe current IP watchdog status.
1.3.6.1.4.1.33283.1.55.1.2ScalaripwPingIPread-onlycurrentIP address of the wdg-monitored object.
1.3.6.1.4.1.33283.1.55.1.3ScalaripwPauseAfterPwOnread-onlycurrentAmount of time in [sec]. Duration of the IP watchdog disable period, applied when watchdog device itself is first powered on.
1.3.6.1.4.1.33283.1.55.1.4ScalaripwPingTimeoutread-onlycurrentConfig value - the RTT timeout.
1.3.6.1.4.1.33283.1.55.1.5ScalaripwRepeatPingPerread-onlycurrentPING REQUEST packet sending: the configured send repeat period, in [miliseconds].
1.3.6.1.4.1.33283.1.55.1.6ScalaripwIgnoreLostCntread-onlycurrentHow many lost PING REPLY packets should get ignored, before activating the relay.
1.3.6.1.4.1.33283.1.55.1.7ScalaripwPauseWdAfterActread-onlycurrentDelay of the IP watchdog pause, applied when the output relay is activated (e.g. the time for controlled device recovery).
1.3.6.1.4.1.33283.1.55.1.8ScalaripwRelayActTimeread-onlycurrentHow many [seconds] should be the output relay activated.
1.3.6.1.4.1.33283.1.55.1.9ScalaripwActualFailedread-onlycurrentHow many unreceived PING REPLY packets are detected so far.
1.3.6.1.4.1.33283.1.55.1.10ScalaripwLastRTTread-onlycurrentRound Trip Time for the last ping echo.
1.3.6.1.4.1.33283.1.55.1.11ScalaripwActualRelayStateread-onlycurrentActual (virtual) output relay status (before mapping this status to the selected hardware).
1.3.6.1.4.1.33283.1.55.2NodesdsOptoInput
1.3.6.1.4.1.33283.1.55.2.1Scalaropto1read-onlycurrentCurrent OPTO1 binary input status.
1.3.6.1.4.1.33283.1.55.2.2Scalaropto2read-onlycurrentCurrent OPTO2 binary input status.
1.3.6.1.4.1.33283.1.55.2.3Scalaropto3read-onlycurrentCurrent OPTO3 binary input status.
1.3.6.1.4.1.33283.1.55.2.4Scalaropto4read-onlycurrentCurrent OPTO4 binary input status.
1.3.6.1.4.1.33283.1.55.2.5Scalaropto5read-onlycurrentCurrent OPTO5 binary input status.
1.3.6.1.4.1.33283.1.55.2.6Scalaropto6read-onlycurrentCurrent OPTO6 binary input status.
1.3.6.1.4.1.33283.1.55.2.7Scalaropto7read-onlycurrentCurrent OPTO7 binary input status.
1.3.6.1.4.1.33283.1.55.2.8Scalaropto8read-onlycurrentCurrent OPTO8 binary input status.
1.3.6.1.4.1.33283.1.55.2.9Scalarlogics0inputread-onlycurrentCurrent LOGIC-S0 binary input status.
1.3.6.1.4.1.33283.1.55.3NodesdsOutputRelay
1.3.6.1.4.1.33283.1.55.3.1ScalarsdsRE1stateread-writecurrentCurrent RELAY 1 output status.
1.3.6.1.4.1.33283.1.55.3.2ScalarsdsRE1cbyread-writecurrentRELAY 1 controled by ...
1.3.6.1.4.1.33283.1.55.3.3ScalarsdsRE1nameread-onlycurrentUser name for RELAY 1.
1.3.6.1.4.1.33283.1.55.3.4ScalarsdsRE2stateread-writecurrentCurrent RELAY 2 output status.
1.3.6.1.4.1.33283.1.55.3.5ScalarsdsRE2cbyread-writecurrentRELAY 2 controled by ...
1.3.6.1.4.1.33283.1.55.3.6ScalarsdsRE2nameread-onlycurrentUser name for RELAY 2.
1.3.6.1.4.1.33283.1.55.3.7ScalarsdsRE3stateread-writecurrentCurrent RELAY 3 output status.
1.3.6.1.4.1.33283.1.55.3.8ScalarsdsRE3cbyread-writecurrentRELAY 3 controled by ...
1.3.6.1.4.1.33283.1.55.3.9ScalarsdsRE3nameread-onlycurrentUser name for RELAY 3.
1.3.6.1.4.1.33283.1.55.3.10ScalarsdsRE4stateread-writecurrentCurrent RELAY 4 output status.
1.3.6.1.4.1.33283.1.55.3.11ScalarsdsRE4cbyread-writecurrentRELAY 4 controled by ...
1.3.6.1.4.1.33283.1.55.3.12ScalarsdsRE4nameread-onlycurrentUser name for RELAY 4.
1.3.6.1.4.1.33283.1.55.3.13ScalarsdsRE5stateread-writecurrentCurrent RELAY 5 output status.
1.3.6.1.4.1.33283.1.55.3.14ScalarsdsRE5cbyread-writecurrentRELAY 5 controled by ...
1.3.6.1.4.1.33283.1.55.3.15ScalarsdsRE5nameread-onlycurrentUser name for RELAY 5.
1.3.6.1.4.1.33283.1.55.3.16ScalarsdsRE6stateread-writecurrentCurrent RELAY 6 output status.
1.3.6.1.4.1.33283.1.55.3.17ScalarsdsRE6cbyread-writecurrentRELAY 6 controled by ...
1.3.6.1.4.1.33283.1.55.3.18ScalarsdsRE6nameread-onlycurrentUser name for RELAY 6.
1.3.6.1.4.1.33283.1.55.4NodesdsPWMoutput
1.3.6.1.4.1.33283.1.55.4.1ScalarsdsPWM1p2freqread-writecurrentActual (PWM 1 and PWM2) generator frequency [Hz].
1.3.6.1.4.1.33283.1.55.4.2ScalarsdsPWM1dutyread-writecurrentActual PWM1 duty control setting 0 - 100 [percent].
1.3.6.1.4.1.33283.1.55.4.4ScalarsdsPWM2dutyread-writecurrentActual PWM2 duty control setting 0 - 100 [percent].
1.3.6.1.4.1.33283.1.55.4.5ScalarsdsPWM3p4freqread-writecurrentActual (PWM 3 and PWM4) generator frequency [Hz].
1.3.6.1.4.1.33283.1.55.4.6ScalarsdsPWM3dutyread-writecurrentActual PWM3 duty control setting 0 - 100 [percent].
1.3.6.1.4.1.33283.1.55.4.8ScalarsdsPWM4dutyread-writecurrentActual PWM4 duty control setting 0 - 100 [percent].
1.3.6.1.4.1.33283.1.55.5NodesdsADCinputs
1.3.6.1.4.1.33283.1.55.5.1ScalarsdsADCrawValue1read-onlycurrentActual analog AD1 input value [raw value 0..4095].
1.3.6.1.4.1.33283.1.55.5.2ScalarsdsADCrawValue2read-onlycurrentActual analog AD2 input value [raw value 0..4095].
1.3.6.1.4.1.33283.1.55.5.3ScalarsdsADCrawValue3read-onlycurrentActual analog AD3 input value [raw value 0..4095].
1.3.6.1.4.1.33283.1.55.5.4ScalarsdsADCrawValue4read-onlycurrentActual analog AD4 input value [raw value 0..4095].
1.3.6.1.4.1.33283.1.55.5.5ScalarsdsADCtext1read-onlycurrentSI textual value for AD1 input (conversion result).
1.3.6.1.4.1.33283.1.55.5.6ScalarsdsADCtext2read-onlycurrentSI textual value for AD2 input (conversion result).
1.3.6.1.4.1.33283.1.55.5.7ScalarsdsADCtext3read-onlycurrentSI textual value for AD3 input (conversion result).
1.3.6.1.4.1.33283.1.55.5.8ScalarsdsADCtext4read-onlycurrentSI textual value for AD4 input (conversion result).
1.3.6.1.4.1.33283.1.55.5.9ScalarsdsADCname1read-onlycurrentUser name for AD1 input.
1.3.6.1.4.1.33283.1.55.5.10ScalarsdsADCname2read-onlycurrentUser name for AD2 input.
1.3.6.1.4.1.33283.1.55.5.11ScalarsdsADCname3read-onlycurrentUser name for AD3 input.
1.3.6.1.4.1.33283.1.55.5.12ScalarsdsADCname4read-onlycurrentUser name for AD4 input.
1.3.6.1.4.1.33283.1.55.5.13ScalarsdsADCunit1read-onlycurrentUser unit for AD1 input.
1.3.6.1.4.1.33283.1.55.5.14ScalarsdsADCunit2read-onlycurrentUser unit for AD2 input.
1.3.6.1.4.1.33283.1.55.5.15ScalarsdsADCunit3read-onlycurrentUser unit for AD3 input.
1.3.6.1.4.1.33283.1.55.5.16ScalarsdsADCunit4read-onlycurrentUser unit for AD4 input.
1.3.6.1.4.1.33283.1.55.6TablesdsONEWIRETablenot-accessiblecurrentA list of all (1-Wire) devices.
1.3.6.1.4.1.33283.1.55.6.1RowsdsONEWIREEntrynot-accessiblecurrentAn entry containing information applicable to a particular ONEWIRE device.
1.3.6.1.4.1.33283.1.55.6.1.1ColumnsdsONEWIREdeviceROMcoderead-onlycurrentInternal ONEWIRE device ROM unique identification code.
1.3.6.1.4.1.33283.1.55.6.1.2ColumnsdsONEWIREactualTempIntegerread-onlycurrentActual temperature for this ONEWIRE sensor, an integral part.
1.3.6.1.4.1.33283.1.55.6.1.3ColumnsdsONEWIREactualTempFracread-onlycurrentActual temperature for this ONEWIRE sensor, a fractional part.
1.3.6.1.4.1.33283.1.55.6.1.4ColumnsdsONEWIREuserNameread-onlycurrentUser name for the actual ONEWIRE device.
1.3.6.1.4.1.33283.1.55.6.1.5ColumnsdsONEWIREactualTempCompleteMul100read-onlycurrentActual temperature for this ONEWIRE sensor: the complete value multiplied by 100 (target precision: two post-zero digits).
1.3.6.1.4.1.33283.1.55.6.1.6ColumnsdsONEWIREtableRowIndexnot-accessiblecurrentONEWIRE device index in this table.
1.3.6.1.4.1.33283.1.55.6.1.7ColumnsdsONEWIREactualRHpercentread-onlycurrentActual RH value for this ONEWIRE sensor
1.3.6.1.4.1.33283.1.55.7NodesdsVersionEntry
1.3.6.1.4.1.33283.1.55.7.1ScalarsdsVersionTextread-onlycurrentSDS device version text.
1.3.6.1.4.1.33283.1.55.7.2ScalarsdsCustomTrap1read-onlycurrentSDS-C custom int32 TRAP.
1.3.6.1.4.1.33283.1.55.8NodesdsGeneralInfoEntry
1.3.6.1.4.1.33283.1.55.8.1ScalarsdsNTPvalueread-onlycurrentActual NTP UTC time value (SDS device is NTP client).
1.3.6.1.4.1.33283.1.55.8.2ScalarsdsSoCtempValueread-onlycurrentActual SoC chip internal temperature, represented in a special units [0..4095]. This needs to be recalculated to get a degC value.
1.3.6.1.4.1.33283.1.55.8.3ScalarsdsOneWireBUSAcountValueread-onlycurrentNumber of discovered 1-Wire devices on BUS A.
1.3.6.1.4.1.33283.1.55.8.4ScalarsdsOneWireBUSBcountValueread-onlycurrentNumber of discovered 1-Wire devices on BUS B.
1.3.6.1.4.1.33283.1.55.8.5ScalarsdsPDgpioStateread-writecurrentPD0 + PD1 + TOPB actual port-pin bit (log1/log0) status.
1.3.6.1.4.1.33283.1.55.8.6ScalarsdsPDgpioDirectionread-writecurrentPD0 + PD1 + TOPB actual port-pin direction (in/out) status.
1.3.6.1.4.1.33283.1.55.8.7ScalarsdsBackUpCoinBatteryVoltageValueread-onlycurrentActual voltage reading of the back-up coin battery, represented as raw ADC value [0..4095]. This needs to be recalculated to get a value in Volts.
1.3.6.1.4.1.33283.1.55.8.10ScalarsdsLOCALTIMEvalueread-onlycurrentActual LOCAL time value (SDS device is NTP client).
1.3.6.1.4.1.33283.1.55.9TablesdsS0Tablenot-accessiblecurrentA list of S0 impulse inputs.
1.3.6.1.4.1.33283.1.55.9.1RowsdsS0Entrynot-accessiblecurrentAn entry containing information applicable to a particular S0 input.
1.3.6.1.4.1.33283.1.55.9.1.1ColumnsdsS0impCountT0read-onlycurrentActual S0 impulse counter value for the tarif state T0 (no tarif signal).
1.3.6.1.4.1.33283.1.55.9.1.2ColumnsdsS0impCountT1read-onlycurrentActual S0 impulse counter value for the tarif state T1 (active tarif signal).
1.3.6.1.4.1.33283.1.55.9.1.3ColumnsdsS0impMoneyOffsetT0read-onlycurrentOffset (impulse count) for cash calculation. Cash value is calculated relatively starting at this offset, for the T0 counter.
1.3.6.1.4.1.33283.1.55.9.1.4ColumnsdsS0impMoneyOffsetT1read-onlycurrentOffset (impulse count) for cash calculation. Cash value is calculated relatively starting at this offset, for the T1 counter.
1.3.6.1.4.1.33283.1.55.9.1.5ColumnsdsS0constantread-onlycurrentS0 output constant (number of impulses for 1 energy unit).
1.3.6.1.4.1.33283.1.55.9.1.6ColumnsdsS0translatedUnitT0read-onlycurrentT0 related S0 impulse count value, recalculated into energy units, in a textual representation.
1.3.6.1.4.1.33283.1.55.9.1.7ColumnsdsS0translatedUnitT1read-onlycurrentT1 related S0 impulse count value, recalculated into energy units, in a textual representation.
1.3.6.1.4.1.33283.1.55.9.1.8ColumnsdsS0translatedCashT0read-onlycurrentT0 related S0 counter value recalculated into cash (total T0 impulse count minus a T0 custom offset), in a textual representation.
1.3.6.1.4.1.33283.1.55.9.1.9ColumnsdsS0translatedCashT1read-onlycurrentT1 related S0 counter value recalculated into cash (total T1 impulse count minus a T1 custom offset), in a textual representation.
1.3.6.1.4.1.33283.1.55.9.1.10ColumnsdsS0actualEnergyFlowread-onlycurrentS0: the actual energy flow value.
1.3.6.1.4.1.33283.1.55.9.1.11ColumnsdsS0constantMTDread-onlycurrentS0 MTD constant.
1.3.6.1.4.1.33283.1.55.9.1.12ColumnsdsS0tableRowIndexnot-accessiblecurrentS0 table row index.
1.3.6.1.4.1.33283.1.55.10TablesdsSDSCEPTablenot-accessiblecurrentA list of SDS-C SDSCEP user values. Equals to sys[140] thru sys[147].
1.3.6.1.4.1.33283.1.55.10.1RowsdsSDSCEPEntrynot-accessiblecurrentAn entry containing the values for SDS-C SDSCEP items.
1.3.6.1.4.1.33283.1.55.10.1.1ColumnsdsSDSCEPvalueread-writecurrentActual value for the particular SDS-C SDSCEP value. First index is starting at sys[140].
1.3.6.1.4.1.33283.1.55.10.1.2ColumnsdsSDSCEPtableRowIndexnot-accessiblecurrentIndex of the particular SDS-C SDSCEP value. Add a number of 139 to this item value, to get the exact sys[] location. Example: value == 1 -> sys[140].
1.3.6.1.4.1.33283.1.55.11NodesdsCOMxEntry
1.3.6.1.4.1.33283.1.55.11.1ScalarsdsETStelnetConnected_COM1read-onlycurrentIs there any Ethernet client connected and using the Eth-to-Serial(COM1) converter, at this moment.
1.3.6.1.4.1.33283.1.55.11.2ScalarsdsETSbaudrate_COM1read-writecurrentCOM1: Actual configured UART baud rate in [bps].
1.3.6.1.4.1.33283.1.55.11.3ScalarsdsETSdataSize_COM1read-writecurrentCOM1: Actual configured UART char data size [number of bits per char].
1.3.6.1.4.1.33283.1.55.11.4ScalarsdsETSstopBits_COM1read-writecurrentCOM1: Actual configured UART number of stop bits [0, 1 or 2 stop bits]
1.3.6.1.4.1.33283.1.55.11.5ScalarsdsETSparity_COM1read-writecurrentCOM1: Actual configured UART parity.
1.3.6.1.4.1.33283.1.55.11.6ScalarsdsETSuartInBytes_COM1read-onlycurrentCOM1: Total number of UART IN bytes.
1.3.6.1.4.1.33283.1.55.11.7ScalarsdsETSuartOutBytes_COM1read-onlycurrentCOM1: Total number of UART OUT bytes.
1.3.6.1.4.1.33283.1.55.11.9ScalarsdsCOM6baudrateread-writecurrentCOM6: Actual configured UART baud rate in [bps].
1.3.6.1.4.1.33283.1.55.11.10ScalarsdsCOM6dataSizeread-writecurrentCOM6: Actual configured UART char data size [number of bits per char].
1.3.6.1.4.1.33283.1.55.11.11ScalarsdsCOM6stopBitsread-writecurrentCOM6: Actual configured UART number of stop bits [0, 1 or 2 stop bits]
1.3.6.1.4.1.33283.1.55.11.12ScalarsdsCOM6parityread-writecurrentCOM6: Actual configured UART parity.
1.3.6.1.4.1.33283.1.55.11.13ScalarsdsCOM6uartInBytesread-onlycurrentCOM6: Total number of UART IN bytes.
1.3.6.1.4.1.33283.1.55.11.14ScalarsdsCOM6uartOutBytesread-onlycurrentCOM6: Total number of UART OUT bytes.
1.3.6.1.4.1.33283.70NodeipwActive-trapTRAP: The current IP watchdog status.
1.3.6.1.4.1.33283.71NodeipwPingIP-trapTRAP: IP address of the wdg monitored object.
1.3.6.1.4.1.33283.72NodeipwPauseAfterPwOn-trapTRAP: Duration of the IP watchdog disable period.
1.3.6.1.4.1.33283.73NodeipwPingTimeout-trapTRAP: IP watchdog RTT timeout.
1.3.6.1.4.1.33283.74NodeipwRepeatPingPer-trapTRAP: IP watchdog send repeat period.
1.3.6.1.4.1.33283.75NodeipwIgnoreLostCnt-trapTRAP: IP watchdog: number of missing packets to ignore.
1.3.6.1.4.1.33283.76NodeipwPauseWdAfterAct-trapTRAP: IP watchog pause applied after output activation.
1.3.6.1.4.1.33283.77NodeipwRelayActTime-trapTRAP: Length of IP watchdog notification output active state.
1.3.6.1.4.1.33283.78NodeipwActualFailed-trapTRAP: number of missing IP watchdog ping responses.
1.3.6.1.4.1.33283.79NodeipwLastRTT-trapTRAP: IP watchdog Round Trip Time for the last ping echo.
1.3.6.1.4.1.33283.80NodeipwActualRelayState-trapTRAP: Actual (virtual) output relay status of IP watchdog.
1.3.6.1.4.1.33283.100Nodeopto1-trapTRAP: optical input 1 status.
1.3.6.1.4.1.33283.101Nodeopto2-trapTRAP: optical input 2 status.
1.3.6.1.4.1.33283.102Nodeopto3-trapTRAP: optical input 3 status.
1.3.6.1.4.1.33283.103Nodeopto4-trapTRAP: optical input 4 status.
1.3.6.1.4.1.33283.104Nodeopto5-trapTRAP: optical input 5 status.
1.3.6.1.4.1.33283.105Nodeopto6-trapTRAP: optical input 6 status.
1.3.6.1.4.1.33283.106Nodeopto7-trapTRAP: optical input 7 status.
1.3.6.1.4.1.33283.107Nodeopto8-trapTRAP: optical input 8 status.
1.3.6.1.4.1.33283.108Nodelogics0input-trapTRAP: LOGIC-S0 input status.
1.3.6.1.4.1.33283.150NodesdsRE1state-trapTRAP: Current RELAY 1 output status.
1.3.6.1.4.1.33283.151NodesdsRE1cby-trapTRAP: RELAY 1 controled by ...
1.3.6.1.4.1.33283.152NodesdsRE1name-trapTRAP: User name for RELAY 1.
1.3.6.1.4.1.33283.153NodesdsRE2state-trapTRAP: Current RELAY 2 output status.
1.3.6.1.4.1.33283.154NodesdsRE2cby-trapTRAP: RELAY 2 controled by ...
1.3.6.1.4.1.33283.155NodesdsRE2name-trapTRAP: User name for RELAY 2.
1.3.6.1.4.1.33283.156NodesdsRE3state-trapTRAP: Current RELAY 3 output status.
1.3.6.1.4.1.33283.157NodesdsRE3cby-trapTRAP: RELAY 3 controled by ...
1.3.6.1.4.1.33283.158NodesdsRE3name-trapTRAP: User name for RELAY 3.
1.3.6.1.4.1.33283.159NodesdsRE4state-trapTRAP: Current RELAY 4 output status.
1.3.6.1.4.1.33283.160NodesdsRE4cby-trapTRAP: RELAY 4 controled by ...
1.3.6.1.4.1.33283.161NodesdsRE4name-trapTRAP: User name for RELAY 4.
1.3.6.1.4.1.33283.162NodesdsRE5state-trapTRAP: Current RELAY 5 output status.
1.3.6.1.4.1.33283.163NodesdsRE5cby-trapTRAP: RELAY 5 controled by ...
1.3.6.1.4.1.33283.164NodesdsRE5name-trapTRAP: User name for RELAY 5.
1.3.6.1.4.1.33283.165NodesdsRE6state-trapTRAP: Current RELAY 6 output status.
1.3.6.1.4.1.33283.166NodesdsRE6cby-trapTRAP: RELAY 6 controled by ...
1.3.6.1.4.1.33283.167NodesdsRE6name-trapTRAP: User name for RELAY 6.
1.3.6.1.4.1.33283.200NodesdsPWM1p2freq-trapTRAP: Actual (PWM1 and PWM2) generator frequency [Hz].
1.3.6.1.4.1.33283.201NodesdsPWM1duty-trapTRAP: Actual PWM1 duty control setting.
1.3.6.1.4.1.33283.203NodesdsPWM2duty-trapTRAP: Actual PWM2 duty control setting.
1.3.6.1.4.1.33283.204NodesdsPWM3p4freq-trapTRAP: Actual (PWM3 and PWM4) generator frequency [Hz].
1.3.6.1.4.1.33283.205NodesdsPWM3duty-trapTRAP: Actual PWM3 duty control setting.
1.3.6.1.4.1.33283.207NodesdsPWM4duty-trapTRAP: Actual PWM4 duty control setting.
1.3.6.1.4.1.33283.250NodesdsADCrawValue1-trapTRAP: Actual AD1 input value [raw].
1.3.6.1.4.1.33283.251NodesdsADCrawValue2-trapTRAP: Actual AD2 input value [raw].
1.3.6.1.4.1.33283.252NodesdsADCrawValue3-trapTRAP: Actual AD3 input value [raw].
1.3.6.1.4.1.33283.253NodesdsADCrawValue4-trapTRAP: Actual AD4 input value [raw].
1.3.6.1.4.1.33283.254NodesdsADCtext1-trapTRAP: Textual conversion output for AD1 input.
1.3.6.1.4.1.33283.255NodesdsADCtext2-trapTRAP: Textual conversion output for AD2 input.
1.3.6.1.4.1.33283.256NodesdsADCtext3-trapTRAP: Textual conversion output for AD3 input.
1.3.6.1.4.1.33283.257NodesdsADCtext4-trapTRAP: Textual conversion output for AD4 input.
1.3.6.1.4.1.33283.258NodesdsADCname1-trapTRAP: User name for AD1 input.
1.3.6.1.4.1.33283.259NodesdsADCname2-trapTRAP: User name for AD2 input.
1.3.6.1.4.1.33283.260NodesdsADCname3-trapTRAP: User name for AD3 input.
1.3.6.1.4.1.33283.261NodesdsADCname4-trapTRAP: User name for AD4 input.
1.3.6.1.4.1.33283.262NodesdsADCunit1-trapTRAP: User unit for AD1 input.
1.3.6.1.4.1.33283.263NodesdsADCunit2-trapTRAP: User unit for AD2 input.
1.3.6.1.4.1.33283.264NodesdsADCunit3-trapTRAP: User unit for AD3 input.
1.3.6.1.4.1.33283.265NodesdsADCunit4-trapTRAP: User unit for AD4 input.
1.3.6.1.4.1.33283.300NodesdsONEWIREactualTempInteger-trapTRAP: Actual temperature [integral part] for this DS18B20 sensor. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.301NodesdsONEWIREactualTempFrac-trapTRAP: Actual temperature [a fractional part] for this DS18B20 sensor. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.302NodesdsONEWIREdeviceROMcode-trapTRAP: DS18B20 device ROM code. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.303NodesdsONEWIREuserName-trapTRAP: User name for this DS18B20 device. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.304NodesdsONEWIREactualTempCompleteMul100-trapTRAP: Actual temperature [a complete value, multiplied by 100]. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.306NodesdsONEWIREactualRHpercent-trapTRAP: Actual RH value for SDS-T-RH sensor on this position. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.400NodesdsVersionText-trapTRAP: SDS device version text.
1.3.6.1.4.1.33283.401NodesdsCustomTrap1-trapTRAP: SDS-C custom int32 trap.
1.3.6.1.4.1.33283.501NodesdsS0impCountT0-trapTRAP: Actual S0 impulse counter value for T0 tarif. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.502NodesdsS0impCountT1-trapTRAP: Actual S0 impulse counter value for T1 tarif. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.503NodesdsS0impMoneyOffsetT0-trapTRAP: Offset (impulse count) for cash calculation for T0. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.504NodesdsS0impMoneyOffsetT1-trapTRAP: Offset (impulse count) for cash calculation for T1. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.505NodesdsS0constant-trapTRAP: S0 output constant (number of impulses for 1 energy unit). INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.506NodesdsS0translatedUnitT0-trapTRAP: T0 related S0 impulse count value as textual energy unit. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.507NodesdsS0translatedUnitT1-trapTRAP: T1 related S0 impulse count value as textual energy unit. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.508NodesdsS0translatedCashT0-trapTRAP: T0 related S0 counter value as textual cash value. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.509NodesdsS0translatedCashT1-trapTRAP: T1 related S0 counter value as textual cash value. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.510NodesdsS0actualEnergyFlow-trapTRAP: S0: the actual energy flow value. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.511NodesdsS0constantMTD-trapTRAP: Actual MTD constat configuration value. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.600NodesdsNTPvalue-trapTRAP: Actual NTP UTC time value (SDS device is NTP client).
1.3.6.1.4.1.33283.601NodesdsSoCtempValue-trapTRAP: Actual SoC chip internal temperature, in special units.
1.3.6.1.4.1.33283.602NodesdsOneWireBUSAcountValue-trapTRAP: Number of discovered 1-Wire devices on BUS A.
1.3.6.1.4.1.33283.603NodesdsOneWireBUSBcountValue-trapTRAP: Number of discovered 1-Wire devices on BUS B.
1.3.6.1.4.1.33283.604NodesdsPDgpioState-trapTRAP: actual port-pin bit (log1/log0) status.
1.3.6.1.4.1.33283.605NodesdsPDgpioDirection-trapTRAP: actual port-pin direction (in/out) status.
1.3.6.1.4.1.33283.606NodesdsBackUpCoinBatteryVoltageValue-trapTRAP: Actual voltage reading of the back-up coin battery, raw ADC value.
1.3.6.1.4.1.33283.610NodesdsLOCALTIMEvalue-trapTRAP: Actual LOCAL time value (SDS device is NTP client).
1.3.6.1.4.1.33283.700NodesdsSDSCEPvalue-trapTRAP: Actual value for the particular SDS-C SDSCEP value. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.800NodesdsETStelnetConnected_COM1-trapTRAP: Is any Ethernet client connected to Eth-to-Serial COM1 converter.
1.3.6.1.4.1.33283.801NodesdsETSbaudrate_COM1trapTRAP: COM1 actual configured UART baud rate in [bps].
1.3.6.1.4.1.33283.802NodesdsETSdataSize_COM1-trapTRAP: COM1 actual configured UART char data size [num of bits].
1.3.6.1.4.1.33283.803NodesdsETSstopBits_COM1-trapTRAP: COM1 actual configured UART number of stop bits.
1.3.6.1.4.1.33283.804NodesdsETSparity_COM1-trapTRAP: COM6 actual configured UART parity.
1.3.6.1.4.1.33283.805NodesdsETSuartInBytes_COM1-trapTRAP: COM6 total number of UART IN bytes.
1.3.6.1.4.1.33283.806NodesdsETSuartOutBytes_COM1trapTRAP: COM6 total number of UART OUT bytes.
1.3.6.1.4.1.33283.811NodesdsCOM6baudrate-trapTRAP: COM6 actual configured UART baud rate in [bps].
1.3.6.1.4.1.33283.812NodesdsCOM6dataSize-trapTRAP: COM6 actual configured UART char data size [num of bits].
1.3.6.1.4.1.33283.813NodesdsCOM6stopBits-trapTRAP: COM6 actual configured UART number of stop bits.
1.3.6.1.4.1.33283.814NodesdsCOM6parity-trapTRAP: COM6 actual configured UART parity.
1.3.6.1.4.1.33283.815NodesdsCOM6uartInBytes-trapTRAP: COM1 total number of UART IN bytes.
1.3.6.1.4.1.33283.816NodesdsCOM6uartOutBytes-trapTRAP: COM1 total number of UART OUT bytes.