The MIB module to describe generic objects for AN-D.cz devices - SDS MICRO (all variants: LIGHT, LIGHT E, LIGHT 2 and DIN, ...), firmware of October 2013 and newer. Updates by 2019 and 2020.
Imported Objects
SNMPv2-SMICounter32 enterprises Gauge32 Integer32 IpAddress MODULE-IDENTITY OBJECT-TYPE TimeTicks
OIDNameAccessStatusDescription
1.3.6.1.4.1.33283Identitymib-AN-Dcz-SDSThe MIB module to describe generic objects for AN-D.cz devices - SDS MICRO (all variants: LIGHT, LIGHT E, LIGHT 2 and DIN, ...), firmware of October 2013 and n…
1.3.6.1.4.1.33283.1Nodesdsxpublic
1.3.6.1.4.1.33283.1.2NodesdsMICROLM
1.3.6.1.4.1.33283.1.2.1NodesdsIPWatchdog
1.3.6.1.4.1.33283.1.2.1.1ScalaripwActiveread-onlycurrentThe current IP watchdog status.
1.3.6.1.4.1.33283.1.2.1.2ScalaripwPingIPread-onlycurrentIP address of the wdg-monitored object.
1.3.6.1.4.1.33283.1.2.1.3ScalaripwPauseAfterPwOnread-onlycurrentAmount of time in [sec]. Duration of the IP watchdog disable period, applied when watchdog device itself is first powered on.
1.3.6.1.4.1.33283.1.2.1.4ScalaripwPingTimeoutread-onlycurrentConfig value - the RTT timeout.
1.3.6.1.4.1.33283.1.2.1.5ScalaripwRepeatPingPerread-onlycurrentPING REQUEST packet sending: the configured send repeat period, in [miliseconds].
1.3.6.1.4.1.33283.1.2.1.6ScalaripwIgnoreLostCntread-onlycurrentHow many lost PING REPLY packets should get ignored, before activating the relay.
1.3.6.1.4.1.33283.1.2.1.7ScalaripwPauseWdAfterActread-onlycurrentDelay of the IP watchdog pause, applied when the output relay is activated (e.g. the time for controlled device recovery).
1.3.6.1.4.1.33283.1.2.1.8ScalaripwRelayActTimeread-onlycurrentHow many [seconds] should be the output relay activated.
1.3.6.1.4.1.33283.1.2.1.9ScalaripwActualFailedread-onlycurrentHow many unreceived PING REPLY packets are detected so far.
1.3.6.1.4.1.33283.1.2.1.10ScalaripwLastRTTread-onlycurrentRound Trip Time for the last ping echo.
1.3.6.1.4.1.33283.1.2.1.11ScalaripwActualRelayStateread-onlycurrentActual (virtual) output relay status (before mapping this status to the selected hardware).
1.3.6.1.4.1.33283.1.2.2NodesdsOptoInput
1.3.6.1.4.1.33283.1.2.2.1Scalaropto1read-onlycurrentCurrent OPTO1 binary input status.
1.3.6.1.4.1.33283.1.2.2.2Scalaropto2read-onlycurrentCurrent OPTO2 binary input status.
1.3.6.1.4.1.33283.1.2.2.3Scalaropto3read-onlycurrentCurrent OPTO3 binary input status.
1.3.6.1.4.1.33283.1.2.2.4Scalarlogics0inputread-onlycurrentCurrent LOGIC-S0 binary input status.
1.3.6.1.4.1.33283.1.2.3NodesdsOutputRelay
1.3.6.1.4.1.33283.1.2.3.1ScalarsdsRE1stateread-writecurrentCurrent RELAY 1 output status.
1.3.6.1.4.1.33283.1.2.3.2ScalarsdsRE1cbyread-writecurrentRELAY 1 controled by ...
1.3.6.1.4.1.33283.1.2.3.3ScalarsdsRE1nameread-onlycurrentUser name for RELAY 1.
1.3.6.1.4.1.33283.1.2.3.4ScalarsdsRE2stateread-writecurrentCurrent RELAY 2 output status.
1.3.6.1.4.1.33283.1.2.3.5ScalarsdsRE2cbyread-writecurrentRELAY 2 controled by ...
1.3.6.1.4.1.33283.1.2.3.6ScalarsdsRE2nameread-onlycurrentUser name for RELAY 2.
1.3.6.1.4.1.33283.1.2.4NodesdsPWMoutput
1.3.6.1.4.1.33283.1.2.4.1ScalarsdsPWM1freqread-writecurrentActual PWM1 frequency [Hz].
1.3.6.1.4.1.33283.1.2.4.2ScalarsdsPWM1dutyread-writecurrentActual PWM1 duty control setting.
1.3.6.1.4.1.33283.1.2.5NodesdsADCinput
1.3.6.1.4.1.33283.1.2.5.1ScalarsdsInADC1read-onlycurrentActual analog AD1 input value [raw value 0..1023].
1.3.6.1.4.1.33283.1.2.5.2ScalarsdsInADC2read-onlycurrentActual analog AD1 input value [raw value 0..1023].
1.3.6.1.4.1.33283.1.2.5.3ScalarsdsInADC3read-onlycurrentActual analog AD3 input value [raw value 0..1023].
1.3.6.1.4.1.33283.1.2.5.4ScalarsdsInADC4read-onlycurrentActual analog AD4 input value [raw value 0..1023].
1.3.6.1.4.1.33283.1.2.5.5ScalarsdsSItextADC1read-onlycurrentSI textual value for AD1.
1.3.6.1.4.1.33283.1.2.5.6ScalarsdsSItextADC2read-onlycurrentSI textual value for AD2.
1.3.6.1.4.1.33283.1.2.5.7ScalarsdsSItextADC3read-onlycurrentSI textual value for AD3.
1.3.6.1.4.1.33283.1.2.5.8ScalarsdsSItextADC4read-onlycurrentSI textual value for AD4.
1.3.6.1.4.1.33283.1.2.5.9ScalarsdsNameADC1read-onlycurrentUser name for AD1.
1.3.6.1.4.1.33283.1.2.5.10ScalarsdsNameADC2read-onlycurrentUser name for AD2.
1.3.6.1.4.1.33283.1.2.5.11ScalarsdsNameADC3read-onlycurrentUser name for AD3.
1.3.6.1.4.1.33283.1.2.5.12ScalarsdsNameADC4read-onlycurrentUser name for AD4.
1.3.6.1.4.1.33283.1.2.5.13ScalarsdsUnitADC1read-onlycurrentUser unit for AD1.
1.3.6.1.4.1.33283.1.2.5.14ScalarsdsUnitADC2read-onlycurrentUser unit for AD2.
1.3.6.1.4.1.33283.1.2.5.15ScalarsdsUnitADC3read-onlycurrentUser unit for AD3.
1.3.6.1.4.1.33283.1.2.5.16ScalarsdsUnitADC4read-onlycurrentUser unit for AD4.
1.3.6.1.4.1.33283.1.2.6TablesdsONEWIRETablenot-accessiblecurrentA list of all (1-Wire) devices.
1.3.6.1.4.1.33283.1.2.6.1RowsdsONEWIREEntrynot-accessiblecurrentAn entry containing information applicable to a particular ONEWIRE device.
1.3.6.1.4.1.33283.1.2.6.1.1ColumnsdsONEWIREdeviceROMcoderead-onlycurrentInternal ONEWIRE device ROM unique identification code.
1.3.6.1.4.1.33283.1.2.6.1.2ColumnsdsONEWIREactualTempIntegerread-onlycurrentActual temperature for this ONEWIRE sensor, an integral part.
1.3.6.1.4.1.33283.1.2.6.1.3ColumnsdsONEWIREactualTempFracread-onlycurrentActual temperature for this ONEWIRE sensor, a fractional part.
1.3.6.1.4.1.33283.1.2.6.1.4ColumnsdsONEWIREuserNameread-onlycurrentUser name for the actual ONEWIRE device.
1.3.6.1.4.1.33283.1.2.6.1.5ColumnsdsONEWIREactualTempCompleteMul100read-onlycurrentActual temperature for this ONEWIRE sensor: the complete value multiplied by 100 (target precision: two post-zero digits).
1.3.6.1.4.1.33283.1.2.6.1.6ColumnsdsONEWIREtableRowIndexnot-accessiblecurrentONEWIRE device index in this table.
1.3.6.1.4.1.33283.1.2.6.1.7ColumnsdsONEWIREactualRHpercentread-onlycurrentActual RH value for this ONEWIRE sensor
1.3.6.1.4.1.33283.1.2.7NodesdsVersionEntry
1.3.6.1.4.1.33283.1.2.7.1ScalarsdsVersionTextread-onlycurrentSDS device version text.
1.3.6.1.4.1.33283.1.2.7.2ScalarsdsCustomTrap1read-onlycurrentSDS-C custom int32 TRAP.
1.3.6.1.4.1.33283.1.2.8NodesdsGeneralInfoEntry
1.3.6.1.4.1.33283.1.2.8.1ScalarsdsNTPvalueread-onlycurrentActual NTP UTC time value (SDS device is NTP client).
1.3.6.1.4.1.33283.1.2.8.2ScalarsdsSoCtempValueread-onlycurrentActual SoC chip internal temperature, represented in a special units [0..1023]. This needs to be recalculated to get a degC value.
1.3.6.1.4.1.33283.1.2.8.3ScalarsdsOneWireBUSAcountValueread-onlycurrentNumber of discovered 1-Wire devices on BUS A.
1.3.6.1.4.1.33283.1.2.8.4ScalarsdsOneWireBUSBcountValueread-onlycurrentNumber of discovered 1-Wire devices on BUS B. Note.: there is no BUS B for SDS MICRO LM device.
1.3.6.1.4.1.33283.1.2.8.5ScalarsdsPD0outputStateread-writecurrentPin PD0 actual output status.
1.3.6.1.4.1.33283.1.2.8.6ScalarsdsPD0Directionread-onlycurrentPin PD0 actual port-pin direction (MICROLM:output only) status.
1.3.6.1.4.1.33283.1.2.8.7ScalarsdsBackUpCoinBatteryVoltageValueread-onlycurrentThis is not used for SDS MICRO LM.
1.3.6.1.4.1.33283.1.2.8.10ScalarsdsLOCALTIMEvalueread-onlycurrentActual LOCAL time value (SDS device is NTP client).
1.3.6.1.4.1.33283.1.2.9TablesdsS0Tablenot-accessiblecurrentA list of S0 impulse inputs.
1.3.6.1.4.1.33283.1.2.9.1RowsdsS0Entrynot-accessiblecurrentAn entry containing information applicable to a particular S0 input.
1.3.6.1.4.1.33283.1.2.9.1.1ColumnsdsS0impCountT0read-onlycurrentActual S0 impulse counter value for the tarif state T0 (no tarif signal).
1.3.6.1.4.1.33283.1.2.9.1.2ColumnsdsS0impCountT1read-onlycurrentActual S0 impulse counter value for the tarif state T1 (active tarif signal).
1.3.6.1.4.1.33283.1.2.9.1.3ColumnsdsS0impMoneyOffsetT0read-onlycurrentOffset (impulse count) for cash calculation. Cash value is calculated relatively starting at this offset, for the T0 counter.
1.3.6.1.4.1.33283.1.2.9.1.4ColumnsdsS0impMoneyOffsetT1read-onlycurrentOffset (impulse count) for cash calculation. Cash value is calculated relatively starting at this offset, for the T1 counter.
1.3.6.1.4.1.33283.1.2.9.1.5ColumnsdsS0constantread-onlycurrentS0 output constant (number of impulses for 1 energy unit).
1.3.6.1.4.1.33283.1.2.9.1.6ColumnsdsS0translatedUnitT0read-onlycurrentT0 related S0 impulse count value, recalculated into energy units, in a textual representation.
1.3.6.1.4.1.33283.1.2.9.1.7ColumnsdsS0translatedUnitT1read-onlycurrentT1 related S0 impulse count value, recalculated into energy units, in a textual representation.
1.3.6.1.4.1.33283.1.2.9.1.8ColumnsdsS0translatedCashT0read-onlycurrentT0 related S0 counter value recalculated into cash (total T0 impulse count minus a T0 custom offset), in a textual representation.
1.3.6.1.4.1.33283.1.2.9.1.9ColumnsdsS0translatedCashT1read-onlycurrentT1 related S0 counter value recalculated into cash (total T1 impulse count minus a T1 custom offset), in a textual representation.
1.3.6.1.4.1.33283.1.2.9.1.10ColumnsdsS0actualEnergyFlowread-onlycurrentS0: the actual energy flow value.
1.3.6.1.4.1.33283.1.2.9.1.11ColumnsdsS0constantMTDread-onlycurrentConfiguration: the MTD constant.
1.3.6.1.4.1.33283.1.2.9.1.12ColumnsdsS0tableRowIndexnot-accessiblecurrentS0 table row index.
1.3.6.1.4.1.33283.1.2.10TablesdsSDSCEPTablenot-accessiblecurrentA list of SDS-C SDSCEP user values. Equals to sys[140] thru sys[147].
1.3.6.1.4.1.33283.1.2.10.1RowsdsSDSCEPEntrynot-accessiblecurrentAn entry containing the values for SDS-C SDSCEP items.
1.3.6.1.4.1.33283.1.2.10.1.1ColumnsdsSDSCEPvalueread-writecurrentActual value for the particular SDS-C SDSCEP value. First index is starting at sys[140].
1.3.6.1.4.1.33283.1.2.10.1.2ColumnsdsSDSCEPtableRowIndexnot-accessiblecurrentIndex of the particular SDS-C SDSCEP value. Add a number of 139 to this item value, to get the exact sys[] location. Example: value == 1 -> sys[140].
1.3.6.1.4.1.33283.1.2.11NodesdsEthToSerialEntry
1.3.6.1.4.1.33283.1.2.11.1ScalarsdsETStelnetConnectedread-onlycurrentIs there any Ethernet client connected and using the Eth-to-Serial converter, at this moment.
1.3.6.1.4.1.33283.1.2.11.2ScalarsdsETSbaudrateread-writecurrentActual configured UART baud rate in [bps].
1.3.6.1.4.1.33283.1.2.11.3ScalarsdsETSdataSizeread-writecurrentActual configured UART char data size [number of bits per char].
1.3.6.1.4.1.33283.1.2.11.4ScalarsdsETSstopBitsread-writecurrentActual configured UART number of stop bits [0, 1 or 2 stop bits]
1.3.6.1.4.1.33283.1.2.11.5ScalarsdsETSparityread-writecurrentActual configured UART parity.
1.3.6.1.4.1.33283.1.2.11.6ScalarsdsETSuartInBytesread-onlycurrentTotal number of UART IN bytes.
1.3.6.1.4.1.33283.1.2.11.7ScalarsdsETSuartOutBytesread-onlycurrentTotal number of UART OUT bytes.
1.3.6.1.4.1.33283.70NodeipwActive-trapTRAP: The current IP watchdog status.
1.3.6.1.4.1.33283.71NodeipwPingIP-trapTRAP: IP address of the wdg monitored object.
1.3.6.1.4.1.33283.72NodeipwPauseAfterPwOn-trapTRAP: Duration of the IP watchdog disable period.
1.3.6.1.4.1.33283.73NodeipwPingTimeout-trapTRAP: IP watchdog RTT timeout.
1.3.6.1.4.1.33283.74NodeipwRepeatPingPer-trapTRAP: IP watchdog send repeat period.
1.3.6.1.4.1.33283.75NodeipwIgnoreLostCnt-trapTRAP: IP watchdog: number of missing packets to ignore.
1.3.6.1.4.1.33283.76NodeipwPauseWdAfterAct-trapTRAP: IP watchog pause applied after output activation.
1.3.6.1.4.1.33283.77NodeipwRelayActTime-trapTRAP: Length of IP watchdog notification output active state.
1.3.6.1.4.1.33283.78NodeipwActualFailed-trapTRAP: number of missing IP watchdog ping responses.
1.3.6.1.4.1.33283.79NodeipwLastRTT-trapTRAP: IP watchdog Round Trip Time for the last ping echo.
1.3.6.1.4.1.33283.80NodeipwActualRelayState-trapTRAP: Actual (virtual) output relay status of IP watchdog.
1.3.6.1.4.1.33283.100Nodeopto1-trapTRAP: optical input 1 status.
1.3.6.1.4.1.33283.101Nodeopto2-trapTRAP: optical input 2 status.
1.3.6.1.4.1.33283.102Nodeopto3-trapTRAP: optical input 3 status.
1.3.6.1.4.1.33283.103Nodelogics0-trapTRAP: LOGIC-S0 input status.
1.3.6.1.4.1.33283.150NodesdsRE1state-trapTRAP: Current RELAY 1 output status.
1.3.6.1.4.1.33283.151NodesdsRE1cby-trapTRAP: RELAY 1 controled by ...
1.3.6.1.4.1.33283.152NodesdsRE1name-trapTRAP: User name for RELAY 1.
1.3.6.1.4.1.33283.153NodesdsRE2state-trapTRAP: Current RELAY 2 output status.
1.3.6.1.4.1.33283.154NodesdsRE2cby-trapTRAP: RELAY 2 controled by ...
1.3.6.1.4.1.33283.155NodesdsRE2name-trapTRAP: User name for RELAY 2.
1.3.6.1.4.1.33283.200NodesdsPWM1freq-trapTRAP: Actual PWM1 generator frequency [Hz].
1.3.6.1.4.1.33283.201NodesdsPWM1duty-trapTRAP: Actual PWM1 duty control setting.
1.3.6.1.4.1.33283.250NodesdsInADC1-trapTRAP: Actual analog AD1 input value [raw].
1.3.6.1.4.1.33283.251NodesdsInADC2-trapTRAP: Actual analog AD1 input value [raw].
1.3.6.1.4.1.33283.252NodesdsInADC3-trapTRAP: Actual analog AD3 input value [raw].
1.3.6.1.4.1.33283.253NodesdsInADC4-trapTRAP: Actual analog AD4 input value [raw].
1.3.6.1.4.1.33283.254NodesdsSItextADC1-trapTRAP: SI textual value for AD1.
1.3.6.1.4.1.33283.255NodesdsSItextADC2-trapTRAP: SI textual value for AD2.
1.3.6.1.4.1.33283.256NodesdsSItextADC3-trapTRAP: SI textual value for AD3.
1.3.6.1.4.1.33283.257NodesdsSItextADC4-trapTRAP: SI textual value for AD4.
1.3.6.1.4.1.33283.258NodesdsNameADC1-trapTRAP: User name for AD1.
1.3.6.1.4.1.33283.259NodesdsNameADC2-trapTRAP: User name for AD2.
1.3.6.1.4.1.33283.260NodesdsNameADC3-trapTRAP: User name for AD3.
1.3.6.1.4.1.33283.261NodesdsNameADC4-trapTRAP: User name for AD4.
1.3.6.1.4.1.33283.262NodesdsUnitADC1-trapTRAP: User unit for AD1.
1.3.6.1.4.1.33283.263NodesdsUnitADC2-trapTRAP: User unit for AD2.
1.3.6.1.4.1.33283.264NodesdsUnitADC3-trapTRAP: User unit for AD3.
1.3.6.1.4.1.33283.265NodesdsUnitADC4-trapTRAP: User unit for AD4.
1.3.6.1.4.1.33283.300NodesdsONEWIREactualTempInteger-trapTRAP: Actual temperature [integral part] for this DS18B20 sensor. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.301NodesdsONEWIREactualTempFrac-trapTRAP: Actual temperature [a fractional part] for this DS18B20 sensor. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.302NodesdsONEWIREdeviceROMcode-trapTRAP: DS18B20 device ROM code. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.303NodesdsONEWIREuserName-trapTRAP: User name for this DS18B20 device. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.304NodesdsONEWIREactualTempCompleteMul100-trapTRAP: Actual temperature [a complete value, multiplied by 100]. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.306NodesdsONEWIREactualRHpercent-trapTRAP: Actual RH value for SDS-T-RH sensor on this position. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.400NodesdsVersionText-trapTRAP: SDS device version text.
1.3.6.1.4.1.33283.401NodesdsCustomTrap1-trapTRAP: SDS-C custom int32 trap.
1.3.6.1.4.1.33283.501NodesdsS0impCountT0-trapTRAP: Actual S0 impulse counter value for T0 tarif. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.502NodesdsS0impCountT1-trapTRAP: Actual S0 impulse counter value for T1 tarif. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.503NodesdsS0impMoneyOffsetT0-trapTRAP: Offset (impulse count) for cash calculation for T0. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.504NodesdsS0impMoneyOffsetT1-trapTRAP: Offset (impulse count) for cash calculation for T1. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.505NodesdsS0constant-trapTRAP: S0 output constant (number of impulses for 1 energy unit). INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.506NodesdsS0translatedUnitT0-trapTRAP: T0 related S0 impulse count value as textual energy unit. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.507NodesdsS0translatedUnitT1-trapTRAP: T1 related S0 impulse count value as textual energy unit. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.508NodesdsS0translatedCashT0-trapTRAP: T0 related S0 counter value as textual cash value. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.509NodesdsS0translatedCashT1-trapTRAP: T1 related S0 counter value as textual cash value. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.510NodesdsS0actualEnergyFlow-trapTRAP: S0: the actual energy flow value. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.511NodesdsS0constantMTD-trapTRAP: S0: configuration - the MTD constant. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.600NodesdsNTPvalue-trapTRAP: Actual NTP UTC time value (SDS device is NTP client).
1.3.6.1.4.1.33283.601NodesdsSoCtempValue-trapTRAP: Actual SoC chip internal temperature, in special units.
1.3.6.1.4.1.33283.602NodesdsOneWireBUSAcountValue-trapTRAP: Number of discovered 1-Wire devices on BUS A.
1.3.6.1.4.1.33283.603NodesdsOneWireBUSBcountValue-trapTRAP: Number of discovered 1-Wire devices on BUS B. None for MICRO LM.
1.3.6.1.4.1.33283.604NodesdsPD0outputState-trapTRAP: PD0 actual port-pin bit (log1-log0) status.
1.3.6.1.4.1.33283.605NodesdsPD0Direction-trapTRAP: PD0 actual port-pin direction (in-out) status.
1.3.6.1.4.1.33283.610NodesdsLOCALTIMEvalue-trapTRAP: Actual LOCAL time value (SDS device is NTP client).
1.3.6.1.4.1.33283.700NodesdsSDSCEPvalue-trapTRAP: Actual value for the particular SDS-C SDSCEP value. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS.
1.3.6.1.4.1.33283.800NodesdsETStelnetConnected-trapTRAP: Is any Ethernet client connected to Eth-to-Serial converter.
1.3.6.1.4.1.33283.801NodesdsETSbaudrate-trapTRAP: Actual configured UART baud rate in [bps].
1.3.6.1.4.1.33283.802NodesdsETSdataSize-trapTRAP: Actual configured UART char data size [num of bits].
1.3.6.1.4.1.33283.803NodesdsETSstopBits-trapTRAP: Actual configured UART number of stop bits.
1.3.6.1.4.1.33283.804NodesdsETSparity-trapTRAP: Actual configured UART parity.
1.3.6.1.4.1.33283.805NodesdsETSuartInBytes-trapTRAP: Total number of UART IN bytes.
1.3.6.1.4.1.33283.806NodesdsETSuartOutBytes-trapTRAP: Total number of UART OUT bytes.