SDS-TTCPRO-ST-MIB
132 objects
The MIB module to describe generic objects for AN-D.cz device - SDS TTCPRO rev3.
Imported Objects
| SNMPv2-SMI | Counter32 enterprises Gauge32 Integer32 IpAddress MODULE-IDENTITY OBJECT-TYPE TimeTicks |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.33283 | Identitymib-AN-Dcz-SDS | The MIB module to describe generic objects for AN-D.cz device - SDS TTCPRO rev3. | ||
| 1.3.6.1.4.1.33283.1 | Nodesdsxpublic | |||
| 1.3.6.1.4.1.33283.1.21 | NodesdsTTC | |||
| 1.3.6.1.4.1.33283.1.21.1 | NodesdsIPWatchdog | |||
| 1.3.6.1.4.1.33283.1.21.1.1 | ScalaripwActive | read-only | current | The current IP watchdog status. |
| 1.3.6.1.4.1.33283.1.21.1.2 | ScalaripwPingIP | read-only | current | IP address of the wdg-monitored object. |
| 1.3.6.1.4.1.33283.1.21.1.3 | ScalaripwPauseAfterPwOn | read-only | current | Amount of time in [sec]. Duration of the IP watchdog disable period, applied when watchdog device itself is first powered on. |
| 1.3.6.1.4.1.33283.1.21.1.4 | ScalaripwPingTimeout | read-only | current | Config value - the RTT timeout. |
| 1.3.6.1.4.1.33283.1.21.1.5 | ScalaripwRepeatPingPer | read-only | current | PING REQUEST packet sending: the configured send repeat period, in [miliseconds]. |
| 1.3.6.1.4.1.33283.1.21.1.6 | ScalaripwIgnoreLostCnt | read-only | current | How many lost PING REPLY packets should get ignored, before activating the relay. |
| 1.3.6.1.4.1.33283.1.21.1.7 | ScalaripwPauseWdAfterAct | read-only | current | Delay of the IP watchdog pause, applied when the output relay is activated (e.g. the time for controlled device recovery). |
| 1.3.6.1.4.1.33283.1.21.1.8 | ScalaripwRelayActTime | read-only | current | How many [seconds] should be the output relay activated. |
| 1.3.6.1.4.1.33283.1.21.1.9 | ScalaripwActualFailed | read-only | current | How many unreceived PING REPLY packets are detected so far. |
| 1.3.6.1.4.1.33283.1.21.1.10 | ScalaripwLastRTT | read-only | current | Round Trip Time for the last ping echo. |
| 1.3.6.1.4.1.33283.1.21.1.11 | ScalaripwActualRelayState | read-only | current | Actual (virtual) output relay status (before mapping this status to the selected hardware). |
| 1.3.6.1.4.1.33283.1.21.2 | NodesdsOptoInput | |||
| 1.3.6.1.4.1.33283.1.21.2.1 | Scalaropto1 | read-only | current | Current OPTO1 binary input status. |
| 1.3.6.1.4.1.33283.1.21.2.2 | Scalaropto2 | read-only | current | Current OPTO2 binary input status. |
| 1.3.6.1.4.1.33283.1.21.2.3 | Scalaropto3 | read-only | current | Current OPTO3 binary input status. |
| 1.3.6.1.4.1.33283.1.21.2.4 | Scalaropto4 | read-only | current | Current OPTO4 binary input status. |
| 1.3.6.1.4.1.33283.1.21.2.5 | Scalarlogics0input | read-only | current | Current LOGIC-S0 binary input status. |
| 1.3.6.1.4.1.33283.1.21.3 | NodesdsOutputRelay | |||
| 1.3.6.1.4.1.33283.1.21.3.1 | ScalarsdsRE1state | read-write | current | Current RELAY 1 output status. |
| 1.3.6.1.4.1.33283.1.21.3.2 | ScalarsdsRE1cby | read-write | current | RELAY 1 controled by ... |
| 1.3.6.1.4.1.33283.1.21.3.3 | ScalarsdsRE1name | read-only | current | User name for RELAY 1. |
| 1.3.6.1.4.1.33283.1.21.3.4 | ScalarsdsRE2state | read-write | current | Current RELAY 2 output status. |
| 1.3.6.1.4.1.33283.1.21.3.5 | ScalarsdsRE2cby | read-write | current | RELAY 2 controled by ... |
| 1.3.6.1.4.1.33283.1.21.3.6 | ScalarsdsRE2name | read-only | current | User name for RELAY 2. |
| 1.3.6.1.4.1.33283.1.21.6 | TablesdsONEWIRETable | not-accessible | current | A list of all (1-Wire) devices. |
| 1.3.6.1.4.1.33283.1.21.6.1 | RowsdsONEWIREEntry | not-accessible | current | An entry containing information applicable to a particular ONEWIRE device. |
| 1.3.6.1.4.1.33283.1.21.6.1.1 | ColumnsdsONEWIREdeviceROMcode | read-only | current | Internal ONEWIRE device ROM unique identification code. |
| 1.3.6.1.4.1.33283.1.21.6.1.2 | ColumnsdsONEWIREactualTempInteger | read-only | current | Actual temperature for this ONEWIRE sensor, an integral part. |
| 1.3.6.1.4.1.33283.1.21.6.1.3 | ColumnsdsONEWIREactualTempFrac | read-only | current | Actual temperature for this ONEWIRE sensor, a fractional part. |
| 1.3.6.1.4.1.33283.1.21.6.1.4 | ColumnsdsONEWIREuserName | read-only | current | User name for the actual ONEWIRE device. |
| 1.3.6.1.4.1.33283.1.21.6.1.5 | ColumnsdsONEWIREactualTempCompleteMul100 | read-only | current | Actual temperature for this ONEWIRE sensor: the complete value multiplied by 100 (target precision: two post-zero digits). |
| 1.3.6.1.4.1.33283.1.21.6.1.6 | ColumnsdsONEWIREtableRowIndex | not-accessible | current | ONEWIRE device index in this table. |
| 1.3.6.1.4.1.33283.1.21.6.1.7 | ColumnsdsONEWIREactualRHpercent | read-only | current | Actual RH value for this ONEWIRE sensor |
| 1.3.6.1.4.1.33283.1.21.7 | NodesdsVersionEntry | |||
| 1.3.6.1.4.1.33283.1.21.7.1 | ScalarsdsVersionText | read-only | current | SDS device version text. |
| 1.3.6.1.4.1.33283.1.21.7.2 | ScalarsdsCustomTrap1 | read-only | current | SDS-C custom int32 TRAP. |
| 1.3.6.1.4.1.33283.1.21.8 | NodesdsGeneralInfoEntry | |||
| 1.3.6.1.4.1.33283.1.21.8.1 | ScalarsdsNTPvalue | read-only | current | Actual NTP UTC time value (SDS device is NTP client). |
| 1.3.6.1.4.1.33283.1.21.8.2 | ScalarsdsSoCtempValue | read-only | current | Actual SoC chip internal temperature, represented in a special units [0..4095]. This needs to be recalculated to get a degC value. |
| 1.3.6.1.4.1.33283.1.21.8.3 | ScalarsdsOneWireBUSAcountValue | read-only | current | Number of discovered 1-Wire devices on BUS A. |
| 1.3.6.1.4.1.33283.1.21.8.4 | ScalarsdsOneWireBUSBcountValue | read-only | current | Number of discovered 1-Wire devices on BUS B. Note.: there is no BUS B for SDS TTCPRO device. |
| 1.3.6.1.4.1.33283.1.21.8.5 | ScalarsdsPDgpioState | read-write | current | PD port (PD7 to PD0) actual port-pin bit (log1/log0) status. |
| 1.3.6.1.4.1.33283.1.21.8.6 | ScalarsdsPDgpioDirection | read-write | current | PD port (PD7 to PD0) actual port-pin direction (in/out) status. |
| 1.3.6.1.4.1.33283.1.21.8.7 | ScalarsdsBackUpCoinBatteryVoltageValue | read-only | current | Actual voltage reading of the back-up coin battery, represented as raw ADC value [0..4095]. This needs to be recalculated to get a value in Volts. |
| 1.3.6.1.4.1.33283.1.21.8.10 | ScalarsdsLOCALTIMEvalue | read-only | current | Actual LOCAL time value (SDS device is NTP client). |
| 1.3.6.1.4.1.33283.1.21.9 | TablesdsS0Table | not-accessible | current | A list of S0 impulse inputs. |
| 1.3.6.1.4.1.33283.1.21.9.1 | RowsdsS0Entry | not-accessible | current | An entry containing information applicable to a particular S0 input. |
| 1.3.6.1.4.1.33283.1.21.9.1.1 | ColumnsdsS0impCountT0 | read-only | current | Actual S0 impulse counter value for the tarif state T0 (no tarif signal). |
| 1.3.6.1.4.1.33283.1.21.9.1.2 | ColumnsdsS0impCountT1 | read-only | current | Actual S0 impulse counter value for the tarif state T1 (active tarif signal). |
| 1.3.6.1.4.1.33283.1.21.9.1.3 | ColumnsdsS0impMoneyOffsetT0 | read-only | current | Offset (impulse count) for cash calculation. Cash value is calculated relatively starting at this offset, for the T0 counter. |
| 1.3.6.1.4.1.33283.1.21.9.1.4 | ColumnsdsS0impMoneyOffsetT1 | read-only | current | Offset (impulse count) for cash calculation. Cash value is calculated relatively starting at this offset, for the T1 counter. |
| 1.3.6.1.4.1.33283.1.21.9.1.5 | ColumnsdsS0constant | read-only | current | S0 output constant (number of impulses for 1 energy unit). |
| 1.3.6.1.4.1.33283.1.21.9.1.6 | ColumnsdsS0translatedUnitT0 | read-only | current | T0 related S0 impulse count value, recalculated into energy units, in a textual representation. |
| 1.3.6.1.4.1.33283.1.21.9.1.7 | ColumnsdsS0translatedUnitT1 | read-only | current | T1 related S0 impulse count value, recalculated into energy units, in a textual representation. |
| 1.3.6.1.4.1.33283.1.21.9.1.8 | ColumnsdsS0translatedCashT0 | read-only | current | T0 related S0 counter value recalculated into cash (total T0 impulse count minus a T0 custom offset), in a textual representation. |
| 1.3.6.1.4.1.33283.1.21.9.1.9 | ColumnsdsS0translatedCashT1 | read-only | current | T1 related S0 counter value recalculated into cash (total T1 impulse count minus a T1 custom offset), in a textual representation. |
| 1.3.6.1.4.1.33283.1.21.9.1.10 | ColumnsdsS0actualEnergyFlow | read-only | current | S0: the actual energy flow value. |
| 1.3.6.1.4.1.33283.1.21.9.1.11 | ColumnsdsS0constantMTD | read-only | current | S0 MTD constant. |
| 1.3.6.1.4.1.33283.1.21.9.1.12 | ColumnsdsS0tableRowIndex | not-accessible | current | S0 table row index. |
| 1.3.6.1.4.1.33283.1.21.10 | TablesdsSDSCEPTable | not-accessible | current | A list of SDS-C SDSCEP user values. Equals to sys[140] thru sys[147]. |
| 1.3.6.1.4.1.33283.1.21.10.1 | RowsdsSDSCEPEntry | not-accessible | current | An entry containing the values for SDS-C SDSCEP items. |
| 1.3.6.1.4.1.33283.1.21.10.1.1 | ColumnsdsSDSCEPvalue | read-write | current | Actual value for the particular SDS-C SDSCEP value. First index is starting at sys[140]. |
| 1.3.6.1.4.1.33283.1.21.10.1.2 | ColumnsdsSDSCEPtableRowIndex | not-accessible | current | Index of the particular SDS-C SDSCEP value. Add a number of 139 to this item value, to get the exact sys[] location. Example: value == 1 -> sys[140]. |
| 1.3.6.1.4.1.33283.1.21.11 | NodesdsCOMxEntry | |||
| 1.3.6.1.4.1.33283.1.21.11.1 | ScalarsdsETStelnetConnected_COM1 | read-only | current | Is there any Ethernet client connected and using the Eth-to-Serial(COM1) converter, at this moment. |
| 1.3.6.1.4.1.33283.1.21.11.2 | ScalarsdsETSbaudrate_COM1 | read-write | current | COM1: Actual configured UART baud rate in [bps]. |
| 1.3.6.1.4.1.33283.1.21.11.3 | ScalarsdsETSdataSize_COM1 | read-write | current | COM1: Actual configured UART char data size [number of bits per char]. |
| 1.3.6.1.4.1.33283.1.21.11.4 | ScalarsdsETSstopBits_COM1 | read-write | current | COM1: Actual configured UART number of stop bits [0, 1 or 2 stop bits] |
| 1.3.6.1.4.1.33283.1.21.11.5 | ScalarsdsETSparity_COM1 | read-write | current | COM1: Actual configured UART parity. |
| 1.3.6.1.4.1.33283.1.21.11.6 | ScalarsdsETSuartInBytes_COM1 | read-only | current | COM1: Total number of UART IN bytes. |
| 1.3.6.1.4.1.33283.1.21.11.7 | ScalarsdsETSuartOutBytes_COM1 | read-only | current | COM1: Total number of UART OUT bytes. |
| 1.3.6.1.4.1.33283.70 | NodeipwActive-trap | TRAP: The current IP watchdog status. | ||
| 1.3.6.1.4.1.33283.71 | NodeipwPingIP-trap | TRAP: IP address of the wdg monitored object. | ||
| 1.3.6.1.4.1.33283.72 | NodeipwPauseAfterPwOn-trap | TRAP: Duration of the IP watchdog disable period. | ||
| 1.3.6.1.4.1.33283.73 | NodeipwPingTimeout-trap | TRAP: IP watchdog RTT timeout. | ||
| 1.3.6.1.4.1.33283.74 | NodeipwRepeatPingPer-trap | TRAP: IP watchdog send repeat period. | ||
| 1.3.6.1.4.1.33283.75 | NodeipwIgnoreLostCnt-trap | TRAP: IP watchdog: number of missing packets to ignore. | ||
| 1.3.6.1.4.1.33283.76 | NodeipwPauseWdAfterAct-trap | TRAP: IP watchog pause applied after output activation. | ||
| 1.3.6.1.4.1.33283.77 | NodeipwRelayActTime-trap | TRAP: Length of IP watchdog notification output active state. | ||
| 1.3.6.1.4.1.33283.78 | NodeipwActualFailed-trap | TRAP: number of missing IP watchdog ping responses. | ||
| 1.3.6.1.4.1.33283.79 | NodeipwLastRTT-trap | TRAP: IP watchdog Round Trip Time for the last ping echo. | ||
| 1.3.6.1.4.1.33283.80 | NodeipwActualRelayState-trap | TRAP: Actual (virtual) output relay status of IP watchdog. | ||
| 1.3.6.1.4.1.33283.100 | Nodeopto1-trap | TRAP: optical input 1 status. | ||
| 1.3.6.1.4.1.33283.101 | Nodeopto2-trap | TRAP: optical input 2 status. | ||
| 1.3.6.1.4.1.33283.102 | Nodeopto3-trap | TRAP: optical input 3 status. | ||
| 1.3.6.1.4.1.33283.103 | Nodeopto4-trap | TRAP: optical input 4 status. | ||
| 1.3.6.1.4.1.33283.104 | Nodelogics0-trap | TRAP: LOGIC-S0 input status. | ||
| 1.3.6.1.4.1.33283.150 | NodesdsRE1state-trap | TRAP: Current RELAY 1 output status. | ||
| 1.3.6.1.4.1.33283.151 | NodesdsRE1cby-trap | TRAP: RELAY 1 controled by ... | ||
| 1.3.6.1.4.1.33283.152 | NodesdsRE1name-trap | TRAP: User name for RELAY 1. | ||
| 1.3.6.1.4.1.33283.153 | NodesdsRE2state-trap | TRAP: Current RELAY 2 output status. | ||
| 1.3.6.1.4.1.33283.154 | NodesdsRE2cby-trap | TRAP: RELAY 2 controled by ... | ||
| 1.3.6.1.4.1.33283.155 | NodesdsRE2name-trap | TRAP: User name for RELAY 2. | ||
| 1.3.6.1.4.1.33283.300 | NodesdsONEWIREactualTempInteger-trap | TRAP: Actual temperature [integral part] for this DS18B20 sensor. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS. | ||
| 1.3.6.1.4.1.33283.301 | NodesdsONEWIREactualTempFrac-trap | TRAP: Actual temperature [a fractional part] for this DS18B20 sensor. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS. | ||
| 1.3.6.1.4.1.33283.302 | NodesdsONEWIREdeviceROMcode-trap | TRAP: DS18B20 device ROM code. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS. | ||
| 1.3.6.1.4.1.33283.303 | NodesdsONEWIREuserName-trap | TRAP: User name for this DS18B20 device. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS. | ||
| 1.3.6.1.4.1.33283.304 | NodesdsONEWIREactualTempCompleteMul100-trap | TRAP: Actual temperature [a complete value, multiplied by 100]. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS. | ||
| 1.3.6.1.4.1.33283.306 | NodesdsONEWIREactualRHpercent-trap | TRAP: Actual RH value for SDS-T-RH sensor on this position. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS. | ||
| 1.3.6.1.4.1.33283.400 | NodesdsVersionText-trap | TRAP: SDS device version text. | ||
| 1.3.6.1.4.1.33283.401 | NodesdsCustomTrap1-trap | TRAP: SDS-C custom int32 trap. | ||
| 1.3.6.1.4.1.33283.501 | NodesdsS0impCountT0-trap | TRAP: Actual S0 impulse counter value for T0 tarif. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS. | ||
| 1.3.6.1.4.1.33283.502 | NodesdsS0impCountT1-trap | TRAP: Actual S0 impulse counter value for T1 tarif. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS. | ||
| 1.3.6.1.4.1.33283.503 | NodesdsS0impMoneyOffsetT0-trap | TRAP: Offset (impulse count) for cash calculation for T0. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS. | ||
| 1.3.6.1.4.1.33283.504 | NodesdsS0impMoneyOffsetT1-trap | TRAP: Offset (impulse count) for cash calculation for T1. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS. | ||
| 1.3.6.1.4.1.33283.505 | NodesdsS0constant-trap | TRAP: S0 output constant (number of impulses for 1 energy unit). INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS. | ||
| 1.3.6.1.4.1.33283.506 | NodesdsS0translatedUnitT0-trap | TRAP: T0 related S0 impulse count value as textual energy unit. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS. | ||
| 1.3.6.1.4.1.33283.507 | NodesdsS0translatedUnitT1-trap | TRAP: T1 related S0 impulse count value as textual energy unit. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS. | ||
| 1.3.6.1.4.1.33283.508 | NodesdsS0translatedCashT0-trap | TRAP: T0 related S0 counter value as textual cash value. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS. | ||
| 1.3.6.1.4.1.33283.509 | NodesdsS0translatedCashT1-trap | TRAP: T1 related S0 counter value as textual cash value. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS. | ||
| 1.3.6.1.4.1.33283.510 | NodesdsS0actualEnergyFlow-trap | TRAP: S0: the actual energy flow value. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS. | ||
| 1.3.6.1.4.1.33283.511 | NodesdsS0constantMTD-trap | TRAP: Actual MTD constat configuration value. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS. | ||
| 1.3.6.1.4.1.33283.600 | NodesdsNTPvalue-trap | TRAP: Actual NTP UTC time value (SDS device is NTP client). | ||
| 1.3.6.1.4.1.33283.601 | NodesdsSoCtempValue-trap | TRAP: Actual SoC chip internal temperature, in special units. | ||
| 1.3.6.1.4.1.33283.602 | NodesdsOneWireBUSAcountValue-trap | TRAP: Number of discovered 1-Wire devices on BUS A. | ||
| 1.3.6.1.4.1.33283.603 | NodesdsOneWireBUSBcountValue-trap | TRAP: Number of discovered 1-Wire devices on BUS B. None for SDS TTCPRO. | ||
| 1.3.6.1.4.1.33283.604 | NodesdsPDgpioState-trap | TRAP: PD port (PD7 to PD0) actual port-pin bit (log1/log0) status. | ||
| 1.3.6.1.4.1.33283.605 | NodesdsPDgpioDirection-trap | TRAP: PD port (PD7 to PD0) actual port-pin direction (in/out) status. | ||
| 1.3.6.1.4.1.33283.606 | NodesdsBackUpCoinBatteryVoltageValue-trap | TRAP: Actual voltage reading of the back-up coin battery, raw ADC value. | ||
| 1.3.6.1.4.1.33283.610 | NodesdsLOCALTIMEvalue-trap | TRAP: Actual LOCAL time value (SDS device is NTP client). | ||
| 1.3.6.1.4.1.33283.700 | NodesdsSDSCEPvalue-trap | TRAP: Actual value for the particular SDS-C SDSCEP value. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS. | ||
| 1.3.6.1.4.1.33283.800 | NodesdsETStelnetConnected_COM1-trap | TRAP: Is any Ethernet client connected to Eth-to-Serial COM1 converter. | ||
| 1.3.6.1.4.1.33283.801 | NodesdsETSbaudrate_COM1trap | TRAP: COM1 actual configured UART baud rate in [bps]. | ||
| 1.3.6.1.4.1.33283.802 | NodesdsETSdataSize_COM1-trap | TRAP: COM1 actual configured UART char data size [num of bits]. | ||
| 1.3.6.1.4.1.33283.803 | NodesdsETSstopBits_COM1-trap | TRAP: COM1 actual configured UART number of stop bits. | ||
| 1.3.6.1.4.1.33283.804 | NodesdsETSparity_COM1-trap | TRAP: COM6 actual configured UART parity. | ||
| 1.3.6.1.4.1.33283.805 | NodesdsETSuartInBytes_COM1-trap | TRAP: COM6 total number of UART IN bytes. | ||