SHELF-MIB
75 objects
The MIB module specific for ADR equipment
Imported Objects
| EQUIPMENT-MIB | SagemBoolean Severity |
| SAGEM-DR-MIB | sagemDr |
| SNMPv2-SMI | Counter32 MODULE-IDENTITY OBJECT-TYPE |
| SNMPv2-TC | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1038.150 | Identityshelf | The MIB module specific for ADR equipment | ||
| 1.3.6.1.4.1.1038.150.1 | ScalaradrHotReset | read-write | current | Software hot reset when this variable is set to TRUE |
| 1.3.6.1.4.1.1038.150.2 | Nodeled | |||
| 1.3.6.1.4.1.1038.150.2.1 | ScalarledNumber | read-only | current | Number of led in equipment. |
| 1.3.6.1.4.1.1038.150.2.2 | TableledTable | not-accessible | current | List of led in equipment. |
| 1.3.6.1.4.1.1038.150.2.2.1 | RowledEntry | not-accessible | current | A particular led of the equipment. |
| 1.3.6.1.4.1.1038.150.2.2.1.1 | ColumnledIndex | read-only | current | A unique value which identify a particular led. |
| 1.3.6.1.4.1.1038.150.2.2.1.2 | ColumnledPosition | read-only | current | A reference to the associated Board on the equipment. |
| 1.3.6.1.4.1.1038.150.2.2.1.3 | ColumnledType | read-only | current | Type of the Led. |
| 1.3.6.1.4.1.1038.150.2.2.1.4 | ColumnledStatus | read-only | current | Status of this Led. |
| 1.3.6.1.4.1.1038.150.3 | NodeholdTime | |||
| 1.3.6.1.4.1.1038.150.3.1 | ScalaradrFailHoldOffTime | read-write | current | Failure hold off time : the time interval during which the defect is present and the failure is not raised |
| 1.3.6.1.4.1.1038.150.3.2 | ScalaradrFailHoldOnTime | read-write | current | Failure hold on time : the time interval during which the defect is cleared and the failure is not |
| 1.3.6.1.4.1.1038.150.20 | Nodeboard | |||
| 1.3.6.1.4.1.1038.150.20.1 | ScalarboardNumber | read-only | current | Number of board in equipment. |
| 1.3.6.1.4.1.1038.150.20.2 | TableboardTable | not-accessible | current | List of board in equipment. |
| 1.3.6.1.4.1.1038.150.20.2.1 | RowboardEntry | not-accessible | current | A particular board of the equipment. |
| 1.3.6.1.4.1.1038.150.20.2.1.1 | ColumnboardIndex | read-only | current | A unique value which identify a particular slot. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to hardwa… |
| 1.3.6.1.4.1.1038.150.20.2.1.2 | ColumnboardSlotName | read-only | current | A DisplayString which identify the name of a particular slot. Its value is fixed at equipment design time. It is usualy related to hardware ex ADR155c : A, B, … |
| 1.3.6.1.4.1.1038.150.20.2.1.3 | ColumnboardExpectType | read-write | current | A value which configure the expected type. If used, this one must be equal to one of existent boardListIndex for the considerated board. Otherwise, the value i… |
| 1.3.6.1.4.1.1038.150.20.2.1.4 | ColumnboardInsertType | read-only | current | When the inserted board doesn't match with the expexted board the boardMismatch failure is generated. The type of the card could be found in hardware inventory. |
| 1.3.6.1.4.1.1038.150.20.2.1.5 | ColumnboardExpectFamily | read-only | current | Board Family corresponding to the specified expected kind. This value is send by the equipment. ex ADR155c : ex ADR2500c : CTRL, FAN, AUX, CCU, PSU, STM1 OPT, … |
| 1.3.6.1.4.1.1038.150.20.2.1.6 | ColumnboardInsertFamily | read-only | current | Board Family corresponding to the type of inserted board. ex ADR155c : ex ADR2500c : CTRL, FAN, AUX, CCU, PSU, STM1 OPT, STM1 ERE, STM4 OPT, STM16 OPT, GBETH, … |
| 1.3.6.1.4.1.1038.150.20.2.1.7 | ColumnboardActive | read-write | current | When the value of this field is set to false, the transmission of this board stop and the board could properly be extracted |
| 1.3.6.1.4.1.1038.150.20.2.1.8 | ColumnboardFirstPortIndex | read-only | current | If the card is a card with physical ports, then the value is the first index of a physical interface (SPI, PPI) in the mib SDH-ETS. Else, the value is 0. |
| 1.3.6.1.4.1.1038.150.20.2.1.9 | ColumnboardProtectionType | read-write | current | The value of this field indicates the kind of wanted card protection. The default value is NONE. if value is changed in cardP(1)then an entry is created in car… |
| 1.3.6.1.4.1.1038.150.20.2.1.10 | ColumnboardMonitor | read-write | current | When the value of this field is set to false, the failure detection is stopped for this board. |
| 1.3.6.1.4.1.1038.150.20.2.1.11 | ColumnboardFailure | read-only | current | Active failures on board |
| 1.3.6.1.4.1.1038.150.20.2.1.12 | ColumnboardSeverity | read-only | current | A reference to failure severity for boards. |
| 1.3.6.1.4.1.1038.150.20.2.1.13 | ColumnboardMissingSev | read-write | current | A reference to failure severity for boards. |
| 1.3.6.1.4.1.1038.150.20.2.1.14 | ColumnboardMismatchSev | read-write | current | A reference to failure severity for boards. |
| 1.3.6.1.4.1.1038.150.20.2.1.15 | ColumnboardDefectiveSev | read-write | current | A reference to failure severity for boards. |
| 1.3.6.1.4.1.1038.150.30 | NodeboardList | |||
| 1.3.6.1.4.1.1038.150.30.1 | ScalarboardListNumber | read-only | current | Number of entry of the boardList Table |
| 1.3.6.1.4.1.1038.150.30.2 | TableboardListTable | not-accessible | current | List of board type able to be managed by this equipment . In order to manage a new type, just insert the board and if the family match with a known family, thi… |
| 1.3.6.1.4.1.1038.150.30.2.1 | RowboardListEntry | not-accessible | current | A particular boardList of the equipment. |
| 1.3.6.1.4.1.1038.150.30.2.1.1 | ColumnboardListIndex | read-only | current | A unique value. |
| 1.3.6.1.4.1.1038.150.30.2.1.2 | ColumnboardListSlot | read-only | current | A reference to the corresponding Slot. |
| 1.3.6.1.4.1.1038.150.30.2.1.3 | ColumnboardListType | read-only | current | In order to manage a new type, just insert the board and if the family match with a known family, this table will be expand automaticaly with the new type inse… |
| 1.3.6.1.4.1.1038.150.40 | NodesoftInv | |||
| 1.3.6.1.4.1.1038.150.40.1 | ScalarsoftInventoryNumber | read-only | current | Number of entry of the softInventory Table |
| 1.3.6.1.4.1.1038.150.40.2 | TablesoftInventoryTable | not-accessible | current | List of software inventory used |
| 1.3.6.1.4.1.1038.150.40.2.1 | RowsoftInventoryEntry | not-accessible | current | A particular boardList of the equipment. |
| 1.3.6.1.4.1.1038.150.40.2.1.1 | ColumnsoftInventoryIndex | read-only | current | A unique value. |
| 1.3.6.1.4.1.1038.150.40.2.1.2 | ColumnsoftInventoryBoard | read-only | current | A reference to the corresponding Slot. This variable is needed because some boards have their owns Applicative and Boot codes. |
| 1.3.6.1.4.1.1038.150.40.2.1.3 | ColumnsoftInventoryType | read-only | current | Indication of type software |
| 1.3.6.1.4.1.1038.150.40.2.1.4 | ColumnsoftInventoryCode | read-only | current | Indication of version code |
| 1.3.6.1.4.1.1038.150.40.2.1.5 | ColumnsoftInventoryExt | read-only | current | Indication of extension code. This one is not mandatory. |
| 1.3.6.1.4.1.1038.150.50 | NodehardInv | |||
| 1.3.6.1.4.1.1038.150.50.1 | ScalarhardInventoryNumber | read-only | current | Number of different hardware inventory in equipment. |
| 1.3.6.1.4.1.1038.150.50.2 | TablehardInventoryTable | not-accessible | current | List of hardware inventory in equipment. A hardware inventory is a description associed to a particular card |
| 1.3.6.1.4.1.1038.150.50.2.1 | RowhardInventoryEntry | not-accessible | current | A particular tInv of the equipment. |
| 1.3.6.1.4.1.1038.150.50.2.1.1 | ColumnhardInventoryIndex | read-only | current | Index of the inventory entry that corresponds to a particular slot |
| 1.3.6.1.4.1.1038.150.50.2.1.2 | ColumnhardInventoryBoard | read-only | current | Family of card inserted in the slot |
| 1.3.6.1.4.1.1038.150.50.2.1.3 | ColumnhardInventoryDescr | read-only | current | The content of the inventory: a textual description |
| 1.3.6.1.4.1.1038.150.100 | Nodelaser | |||
| 1.3.6.1.4.1.1038.150.100.1 | ScalarlaserNumber | read-only | current | Number of optical interface in equipment. |
| 1.3.6.1.4.1.1038.150.100.2 | TablelaserTable | not-accessible | current | List of synchronous physical interface in equipment. |
| 1.3.6.1.4.1.1038.150.100.2.1 | RowlaserEntry | not-accessible | current | A particular synchronous physical interface of the equipment. |
| 1.3.6.1.4.1.1038.150.100.2.1.1 | ColumnlaserIndex | read-only | current | |
| 1.3.6.1.4.1.1038.150.100.2.1.2 | ColumnlaserTxEnable | read-write | current | Enable(true) or disable(false) the laser output of the interface. |
| 1.3.6.1.4.1.1038.150.100.2.1.3 | ColumnlaserALSEnable | read-write | current | Automatic Laser Shutdown enable(true) or disable(false). When enabled, this function cuts the laser output when a los is detected on input signal. |
| 1.3.6.1.4.1.1038.150.100.2.1.4 | ColumnlaserALSRestart2s | read-write | current | Operator command to start a one shot emission during 2s. |
| 1.3.6.1.4.1.1038.150.100.2.1.5 | ColumnlaserALSRestart90s | read-write | current | Operator command to start a one shot emission during 90s. |
| 1.3.6.1.4.1.1038.150.120 | Nodeeow | |||
| 1.3.6.1.4.1.1038.150.120.1 | ScalareowNumber | read-only | current | Number of EOW port in equipment. |
| 1.3.6.1.4.1.1038.150.120.2 | TableeowTable | not-accessible | current | List of EOW port in equipment. |
| 1.3.6.1.4.1.1038.150.120.2.1 | RoweowEntry | not-accessible | current | A particular EOW port of the equipment. |
| 1.3.6.1.4.1.1038.150.120.2.1.1 | ColumneowIndex | read-only | current | A unique value which identify a particular EOW port. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to ha… |
| 1.3.6.1.4.1.1038.150.120.2.1.2 | ColumneowName | read-only | current | A text string which identifies the particular entry among the EOW port entries. |
| 1.3.6.1.4.1.1038.150.120.2.1.6 | ColumneowSrcType | read-write | current | A reference to the object which sends the data flow to this interface. Usually the value is the oid of a vc12 or a connection. |
| 1.3.6.1.4.1.1038.150.120.2.1.7 | ColumneowSrcPtr | read-write | current | A reference to the object which sends the data flow to this interface. Usually the value is the oid of a vc12 or a connection. |
| 1.3.6.1.4.1.1038.150.120.2.1.8 | ColumneowSinkType | read-write | current | A reference to the object which sends the data flow to this interface. Usually the value is the oid of a vc12 or a connection. |
| 1.3.6.1.4.1.1038.150.120.2.1.9 | ColumneowSinkPtr | read-write | current | A reference to the object which sends the data flow to this interface. Usually the value is the oid of a vc12 or a connection. |
| 1.3.6.1.4.1.1038.150.120.2.1.10 | ColumneowClockMode | read-write | current | Select the direction of the two external synchronisation lines. |