MIB Viewer

SIAE-CARRIER-AGGRL1-MIB

21 objects
Carrier hybrid aggregation management for SIAE equipments.
OIDNameAccessStatusDescription
1.3.6.1.4.1.3373.1103.104IdentitycarrierAggrCarrier hybrid aggregation management for SIAE equipments.
1.3.6.1.4.1.3373.1103.104.1ScalarcarrierAggrMibVersionread-onlycurrentNumerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.0…
1.3.6.1.4.1.3373.1103.104.2TablecarrierAggrSensorTablenot-accessiblecurrentTable with Radio(s) interface(s) that can be associated to an entry of carrierAggrActuatorTable.
1.3.6.1.4.1.3373.1103.104.2.1RowcarrierAggrSensorEntrynot-accessiblecurrentA row in the carrierAggrSensorTable.
1.3.6.1.4.1.3373.1103.104.2.1.1ColumncarrierAggrSensorIndexread-onlycurrentThis object identifies the index of carrierAggrSensorTable.
1.3.6.1.4.1.3373.1103.104.2.1.2ColumncarrierAggrSensorRowstatusread-createcurrentThe status of this sensor entry. An entry may not exist in the active state unless all objects in the entry have an appropriate value: SensorIfIndex must be se…
1.3.6.1.4.1.3373.1103.104.2.1.3ColumncarrierAggrSensorAdminStatusread-createcurrentAdministative status of the sensor. The value down(1) turns off all actuators associated with this sensor.
1.3.6.1.4.1.3373.1103.104.2.1.4ColumncarrierAggrSensorIfIndexread-createcurrentThis object accepts a greater than zero value to identify an interface in ifTable. Some parameters of the radio associated to this interface is monitored and a…
1.3.6.1.4.1.3373.1103.104.2.1.5ColumncarrierAggrSensorHitlessCapabilityread-onlycurrentThis capability is related to HITLESS Behaviour carrierAggrSensorHitlessBehaviour.
1.3.6.1.4.1.3373.1103.104.2.1.6ColumncarrierAggrSensorHitlessBehaviourread-createcurrentThe hitless behaviour. When enabled, data related to the current ACM zone is notified to an external N.E. aggregator, so it can dynamically exclude/include the…
1.3.6.1.4.1.3373.1103.104.2.1.7ColumncarrierAggrSensorHitlessModeread-createcurrentThe policy to select the hitless profile (i.e. the lowest one under which a N.E. aggregator excludes the carrier from an existing aggregation). auto(1): Tx Low…
1.3.6.1.4.1.3373.1103.104.2.1.8ColumncarrierAggrSensorHitlessProfileread-createcurrentThe hitless profile in case of carrierHyAggrHitlessBehaviour set as enabled and carrierHyAggrHitlessMode set as manual.
1.3.6.1.4.1.3373.1103.104.2.1.9ColumncarrierAggrSensorHitlessStatusread-onlycurrentThe working zone of the radio link.
1.3.6.1.4.1.3373.1103.104.3TablecarrierAggrActuatorTablenot-accessiblecurrentTable with Lan(s) interface that can be associated to an entry of carrierAggrSensorTable.
1.3.6.1.4.1.3373.1103.104.3.1RowcarrierAggrActuatorEntrynot-accessiblecurrentA row in the carrierAggrActuatorTable.
1.3.6.1.4.1.3373.1103.104.3.1.1ColumncarrierAggrActuatorIndexread-onlycurrentThis object identifies the carrier aggr Actuator inside the Network Element.
1.3.6.1.4.1.3373.1103.104.3.1.2ColumncarrierAggrActuatorRowStatusread-createcurrentThe status of this entry. An entry may not exist in the active state unless all objects in the entry have an appropriate value: carrierAggrActuatorIfIndex must…
1.3.6.1.4.1.3373.1103.104.3.1.3ColumncarrierAggrActuatorAdminStatusread-createcurrentAdministative status of the actuator. The value down(1) turns it off. Other actuators associated with the same sensor remain active.
1.3.6.1.4.1.3373.1103.104.3.1.4ColumncarrierAggrActuatorIfIndexread-createcurrentThis object accepts a greater than zero value to identify an interface in ifTable. The notify received from the connected sensor is forwarded to the remote agg…
1.3.6.1.4.1.3373.1103.104.3.1.5ColumncarrierAggrActuatorSensorIndexread-createcurrentThis object connects this actuator to a sensor.
1.3.6.1.4.1.3373.1103.104.3.1.6ColumncarrierAggrActuatorConcIpAddrread-onlycurrentThis object is used to contain the Ip address of the equipment connected with this Lan (the concatenator unit)