MIB Viewer

SIAE-MANOP-MIB

14 objects
Manual Operation management.
Imported Objects
SIAE-ALARM-MIBAlarmSeverityCode AlarmStatus
SIAE-TREE-MIBsiaeMib
SNMPv2-SMIInteger32 MODULE-IDENTITY OBJECT-TYPE Unsigned32
OIDNameAccessStatusDescription
1.3.6.1.4.1.3373.1103.71IdentitymanualOperationManual Operation management.
1.3.6.1.4.1.3373.1103.71.0NodemanualOpTrap
1.3.6.1.4.1.3373.1103.71.1ScalarmanualOpMibVersionread-onlycurrentNumerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.0…
1.3.6.1.4.1.3373.1103.71.2TablemanualOpTablenot-accessiblecurrentTable with manual operation record.
1.3.6.1.4.1.3373.1103.71.2.1RowmanualOpRecordnot-accessiblecurrentManual operation record.
1.3.6.1.4.1.3373.1103.71.2.1.1ColumnmanualOpIdread-onlycurrentManual operation index.
1.3.6.1.4.1.3373.1103.71.2.1.2ColumnmanualOpObjectIdread-onlycurrentObject identifier of the manual operation active element.
1.3.6.1.4.1.3373.1103.71.2.1.3ColumnmanualOpEventTimeread-onlycurrentThe time (in seconds since 01-Gen-1970) when the event was registered in the table.
1.3.6.1.4.1.3373.1103.71.2.1.4ColumnmanualOpValueTyperead-onlycurrentThe type of the value. One and only one of the value object that follow is used for a given row in this table, based on this type.
1.3.6.1.4.1.3373.1103.71.2.1.5ColumnmanualOpIntegerValread-onlycurrentThe value when manualOpValueType is 'integer32'.
1.3.6.1.4.1.3373.1103.71.2.1.6ColumnmanualOpOidValread-onlycurrentThe value when manualOpValueType is 'objectId'.
1.3.6.1.4.1.3373.1103.71.3ScalarmanualOpActiveread-onlycurrentManual Operation active on the equipment.
1.3.6.1.4.1.3373.1103.71.4ScalarmanualOpActiveSeverityCoderead-writecurrentDefines the severity associated to manualOpActive and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.71.5ScalarmanualOpTimeOutread-writecurrentThis object defines the time (in seconds) after wich the manual operations are cleared. The maximum value is equivalent to 48 hours. A zero means no Time-out.