MIB Viewer

SIAE-PMG828-MIB

47 objects
Perforfamce Monitoring according to ITU-T G.829 for Radio Link and E1 Tributaries
OIDNameAccessStatusDescription
1.3.6.1.4.1.3373.1103.11IdentitypmG828calusePerforfamce Monitoring according to ITU-T G.829 for Radio Link and E1 Tributaries
1.3.6.1.4.1.3373.1103.11.1ScalarpmG828MibVersionread-onlycurrentNumerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.0…
1.3.6.1.4.1.3373.1103.11.2TablepmG828CounterTablenot-accessiblecurrentTable with PmG828 records: one record for 1+0 configuration and two record for 1+1 configuration.
1.3.6.1.4.1.3373.1103.11.2.1RowpmG828CounterRecordnot-accessiblecurrentPmG828Counter record.
1.3.6.1.4.1.3373.1103.11.2.1.1ColumnpmG828TPointIdread-onlycurrentThis object identifies the Termination Point.
1.3.6.1.4.1.3373.1103.11.2.1.2ColumnpmG828CounterBlockIdread-onlycurrentThis object identifies the counters block and the counter type according to the following code: 1 Current Daily counters 2 Daily counters (Day before counters)…
1.3.6.1.4.1.3373.1103.11.2.1.3ColumnpmG828CounterBlockTyperead-onlycurrentThe type of the counter block.
1.3.6.1.4.1.3373.1103.11.2.1.4ColumnpmG828CounterBlockStatusread-onlycurrentStatus of the block counter.
1.3.6.1.4.1.3373.1103.11.2.1.5ColumnpmG828CounterTimeStampread-onlycurrentThe object is the time when the performance record is closed reported as the second number since 1-Gen-1970.
1.3.6.1.4.1.3373.1103.11.2.1.6ColumnpmG828BBECounterread-onlycurrentG828 BBE counter.
1.3.6.1.4.1.3373.1103.11.2.1.7ColumnpmG828ESCounterread-onlycurrentG828 Es counter.
1.3.6.1.4.1.3373.1103.11.2.1.8ColumnpmG828SESCounterread-onlycurrentG828 SES counter.
1.3.6.1.4.1.3373.1103.11.2.1.9ColumnpmG828UASCounterread-onlycurrentG828 UAS counter.
1.3.6.1.4.1.3373.1103.11.2.1.10ColumnpmG828SEPCounterread-onlycurrentG828 SEP counter.
1.3.6.1.4.1.3373.1103.11.3TablepmG828TpClassTablenot-accessiblecurrentTable with PmG828TpClass records: one record for 1+0 configuration and two record for 1+1 configuration.
1.3.6.1.4.1.3373.1103.11.3.1RowpmG828TpClassRecordnot-accessiblecurrentPmG828TpClass record.
1.3.6.1.4.1.3373.1103.11.3.1.1ColumnpmG828TpClassIdread-onlycurrentThis object identifies the Termination Point.
1.3.6.1.4.1.3373.1103.11.3.1.2ColumnpmG828TpClassStartStopread-createcurrentThis object is used to start and to stop the Perfomance Monitoring counter evaluation.
1.3.6.1.4.1.3373.1103.11.3.1.3ColumnpmG828TpClassLabelread-onlycurrentASCII string used to identify the Tp class: for example: pmG828TpClassBranchId = 1 label = Radio 1 pmG828TpClassBranchId = 2 label = Radio 2 pmG828TpClassBranc…
1.3.6.1.4.1.3373.1103.11.3.1.4ColumnpmG828TpClassTimeStampread-onlycurrent
1.3.6.1.4.1.3373.1103.11.3.1.5ColumnpmG828TpClass15MEsAlarmread-onlycurrent15 minutes ES threshold cross alarm with associated severity.
1.3.6.1.4.1.3373.1103.11.3.1.6ColumnpmG828TpClass15MSesAlarmread-onlycurrent15 minutes SES threshold cross alarm with associated severity.
1.3.6.1.4.1.3373.1103.11.3.1.7ColumnpmG828TpClass15MSepAlarmread-onlycurrent15 minutes SEP threshold cross alarm with associated severity.
1.3.6.1.4.1.3373.1103.11.3.1.8ColumnpmG828TpClass24HEsAlarmread-onlycurrentDaily ES threshold cross alarm with associated severity.
1.3.6.1.4.1.3373.1103.11.3.1.9ColumnpmG828TpClass24HSesAlarmread-onlycurrentDaily SES threshold cross alarm with associated severity.
1.3.6.1.4.1.3373.1103.11.3.1.10ColumnpmG828TpClass24HSepAlarmread-onlycurrentDaily SEP threshold cross alarm with associated severity.
1.3.6.1.4.1.3373.1103.11.3.1.11ColumnpmG828TpClassUasAlarmread-onlycurrentUAS alarm with associated severity.
1.3.6.1.4.1.3373.1103.11.3.1.12ColumnpmG828TpClass15MEsThresholdread-createcurrentNumber of ES within 15 minutes to set pmG828TpClass15MEsAlarm (zero value disables the alarm).
1.3.6.1.4.1.3373.1103.11.3.1.13ColumnpmG828TpClass15MSesThresholdread-createcurrentNumber of SES within 15 minutes to set pmG828TpClass15MSesAlarm (zero value disables the alarm).
1.3.6.1.4.1.3373.1103.11.3.1.14ColumnpmG828TpClass15MSepThresholdread-createcurrentNumber of SEP within 15 minutes to set pmG828TpClass15MSepAlarm (zero value disables the alarm).
1.3.6.1.4.1.3373.1103.11.3.1.15ColumnpmG828TpClass24HEsThresholdread-createcurrentNumber of ES within one day to set pmG828TpClass24HEsAlarm (zero value disables the alarm).
1.3.6.1.4.1.3373.1103.11.3.1.16ColumnpmG828TpClass24HSesThresholdread-createcurrentNumber of SES within one day to set pmG828TpClass24HSesAlarm (zero value disables the alarm).
1.3.6.1.4.1.3373.1103.11.3.1.17ColumnpmG828TpClass24HSepThresholdread-createcurrentNumber of SEP within one day to set pmG828TpClass24HSepAlarm (zero value disables the alarm).
1.3.6.1.4.1.3373.1103.11.3.1.18ColumnpmG828TpClassRowStatusread-createcurrentStatus of this row of pmRxPwrTpClass.
1.3.6.1.4.1.3373.1103.11.4TablepmG828TpMaintTablenot-accessiblecurrentTable with Command for maintenance of Termination Point. Objects in this table is not persistent. An Instance of this table is created on creation of pmG828TpC…
1.3.6.1.4.1.3373.1103.11.4.1RowpmG828TpMaintRecordnot-accessiblecurrentPmG828 Termination Point Maintenance record.
1.3.6.1.4.1.3373.1103.11.4.1.1ColumnpmG828TpMaintCounterClearread-writecurrentThis object is used to clear the Perfomance Monitoring counters.
1.3.6.1.4.1.3373.1103.11.4.1.2ColumnpmG828TpMaintAlarmClearread-writecurrentThis object is used to clear the Perfomance Monitoring threshold cross alarms.
1.3.6.1.4.1.3373.1103.11.5ScalarpmG828NSesSetUASread-writecurrentNumber of SES (according G.828) to set UAS.
1.3.6.1.4.1.3373.1103.11.6ScalarpmG828NSesResetUASread-writecurrentNumber of seconds whitout errors (according G.828) to reset UAS.
1.3.6.1.4.1.3373.1103.11.7ScalarpmG828TpClass15MEsAlarmSeverityCoderead-writecurrentDefines the severity associated to the pmG828TpClass15MEsAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.11.8ScalarpmG828TpClass15MSesAlarmSeverityCoderead-writecurrentDefine the severity associated to the pmG828TpClass15MSesAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.11.9ScalarpmG828TpClass24HEsAlarmSeverityCoderead-writecurrentDefine the severity associated to the pmG828TpClass15MEsAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.11.10ScalarpmG828TpClass24HSesAlarmSeverityCoderead-writecurrentDefine the severity associated to the pmG828TpClass15MSesAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.11.11ScalarpmG828TpClassUASAlarmSeverityCoderead-writecurrentDefine the severity associated to the pmG828TpClassUASAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.11.12ScalarpmG828TpClass15MSepAlarmSeverityCoderead-writecurrentDefine the severity associated to the pmG828TpClass15MSepAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.11.13ScalarpmG828TpClass24HSepAlarmSeverityCoderead-writecurrentDefine the severity associated to the pmG828TpClass24HSepAlarm and enables/disables the trap generation on status change event.