MIB Viewer

SIAE-PTP-MIB

139 objects
SIAE's Precision Time Protocol MIB. For details see: [1] IEEE Std 1588(TM)-2008, Standard for a Precision Clock Synchronization Protocol for Networked Measurement and Control Systems, 2008. [2] Recommendation ITU-T G.8275.1/Y1369.1, Precision time protocol telecom profile for phase/time synchronization with full timing support from the network, draft 4 Apr 2014 .
OIDNameAccessStatusDescription
1.3.6.1.4.1.3373.1103.100IdentityptpSIAE's Precision Time Protocol MIB. For details see: [1] IEEE Std 1588(TM)-2008, Standard for a Precision Clock Synchronization Protocol for Networked Measurem…
1.3.6.1.4.1.3373.1103.100.1ScalarptpMibVersionread-onlycurrentNumerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.0…
1.3.6.1.4.1.3373.1103.100.2NodeptpProfileDataSet
1.3.6.1.4.1.3373.1103.100.2.1ScalarptpSystemProfileread-onlycurrentThis object specifies the PTP Profile implemented on the system.
1.3.6.1.4.1.3373.1103.100.2.2ScalarptpProfileNameread-onlycurrentThis object describes the PTP Profile implemented on the system.
1.3.6.1.4.1.3373.1103.100.2.3ScalarptpProfilePrimaryVersionread-onlycurrentThe version of the profile consist of two fields: a primaryVersion and a revisionNumber. The profileVersion shall be printed as primaryVersion.revisionNumber
1.3.6.1.4.1.3373.1103.100.2.4ScalarptpProfileRevisionNumberread-onlycurrentThe version of the profile consist of two fields: a primaryVersion and a revisionNumber. The profileVersion shall be printed as primaryVersion.revisionNumber
1.3.6.1.4.1.3373.1103.100.2.5ScalarptpProfileIdentifierread-onlycurrentThis object show the PTP Profile version on the system.
1.3.6.1.4.1.3373.1103.100.3NodeptpSpecificDataSet
1.3.6.1.4.1.3373.1103.100.3.1TableptpSpecificDataSetTablenot-accessiblecurrentTable of vendor specific information about the PTP clock for all domains.
1.3.6.1.4.1.3373.1103.100.3.1.1RowptpSpecificDataSetEntrynot-accessiblecurrentContains vendor specific information for a particular PTP clock. Where not otherwise specified, every object of this entry can be modified with the conceptual …
1.3.6.1.4.1.3373.1103.100.3.1.1.1ColumnptpAdminStatusread-writecurrentThis object states if PTP is enabled or disabled for this PTP Clock in order to switch on/off the PTP protocol.
1.3.6.1.4.1.3373.1103.100.3.1.1.2ColumnptpStaticPortRoleread-writecurrentThis object states that in the PTP Clock the A-BMCA is disabled and it is working in Static PTP Port Role mode.
1.3.6.1.4.1.3373.1103.100.3.1.1.3ColumnptpClockStateread-onlycurrentThis object shows the current state of the PTP Clock State Machine
1.3.6.1.4.1.3373.1103.100.3.1.1.4ColumnptpComplianceread-writecurrentThis object states if the clock is strictly profile compliant. The meaning of looseCompatibility is application dependent.
1.3.6.1.4.1.3373.1103.100.3.2TableptpSpecificAlarmTablenot-accessiblecurrentTable of vendor specific information about the PTP clock for all domains.
1.3.6.1.4.1.3373.1103.100.3.2.1RowptpSpecificAlarmEntrynot-accessiblecurrentContains vendor specific alarm information for a particular PTP clock.
1.3.6.1.4.1.3373.1103.100.3.2.1.1ColumnptpFreeRunningAlarmread-onlycurrentThis alarm is raised when ptpClockState is set to freerun(1).
1.3.6.1.4.1.3373.1103.100.3.2.1.2ColumnptpHoldoverInSpecAlarmread-onlycurrentThis alarm is raised when ptpClockState is set to holdoverInSpec(4).
1.3.6.1.4.1.3373.1103.100.3.2.1.3ColumnptpHoldoverOutOfSpecAlarmread-onlycurrentThis alarm is raised when ptpClockState is set to holdoverOutOfSpec(5).
1.3.6.1.4.1.3373.1103.100.3.3ScalarptpFreeRunningAlarmSeverityCoderead-writecurrentThis object defines the severity associated to ptpFreeRunningAlarm and enables or disables the sending of the SNMP Trap on the alarm status transition.
1.3.6.1.4.1.3373.1103.100.3.4ScalarptpHoldoverInSpecAlarmSeverityCoderead-writecurrentThis object defines the severity associated to ptpHoldoverInSpecAlarm and enables or disables the sending of the SNMP Trap on the alarm status transition.
1.3.6.1.4.1.3373.1103.100.3.5ScalarptpHoldoverOutOfSpecAlarmSeverityCoderead-writecurrentThis object defines the severity associated to ptpHoldoverOutOfSpecAlarm and enables or disables the sending of the SNMP Trap on the alarm status transition.
1.3.6.1.4.1.3373.1103.100.4NodeptpDefaultDataSet
1.3.6.1.4.1.3373.1103.100.4.1TableptpClockDataSetTablenot-accessiblecurrentTable of information about the PTP clock Default Datasets for all domains.
1.3.6.1.4.1.3373.1103.100.4.1.1RowptpClockDataSetEntrynot-accessiblecurrentContains the information of the clock on a particular doamin. This table will be initialised with default values if the clock is operating as a boundary or ord…
1.3.6.1.4.1.3373.1103.100.4.1.1.1ColumnptpClockDomainIndexread-onlycurrentThis object specifies the domain number used to create logical group of PTP devices. The Clock Domain is a logical group of clocks and devices that synchronize…
1.3.6.1.4.1.3373.1103.100.4.1.1.2ColumnptpClockTypeIndexread-onlycurrentThis object specifies the clock type as defined in the Textual convention description.
1.3.6.1.4.1.3373.1103.100.4.1.1.3ColumnptpClockInstanceIndexread-onlycurrentThis object specifies the instance of the Clock for this clock type for the given domain.
1.3.6.1.4.1.3373.1103.100.4.1.1.4ColumnptpClockIdentityread-onlycurrentThis is the unique identity of the local clock or management node. This should be the smptpDomainClockIdentity of the domain indicated by the ptpDomainNumber. …
1.3.6.1.4.1.3373.1103.100.4.1.1.5ColumnptpClockTwoStepFlagread-onlycurrentThis value is TRUE if the clock is two step clock, otherwise it is FALSE. If this value is configured as TRUE, then PTP will transmit the originTimeStamp only …
1.3.6.1.4.1.3373.1103.100.4.1.1.6ColumnptpClockNumberPortsread-onlycurrentThis indicates the number of PTP ports on the device. For an ordinary clock this value should be 1.
1.3.6.1.4.1.3373.1103.100.4.1.1.7ColumnptpClockClassread-onlycurrentThis object specifies the default dataset Quality Class.
1.3.6.1.4.1.3373.1103.100.4.1.1.8ColumnptpClockAccuracyread-onlycurrentThis object specifies the default dataset Quality Accurarcy.
1.3.6.1.4.1.3373.1103.100.4.1.1.9ColumnptpClockOffsetScaledLogVarianceread-onlycurrentThis value is an estimate of the variations of the local clock from a linear timescale when it is not synchronized to another clock using the protocol. The ini…
1.3.6.1.4.1.3373.1103.100.4.1.1.10ColumnptpClockPriority1read-createcurrentThis value is used by BMC algorithm to select the best master clock. Lower values take precedence.
1.3.6.1.4.1.3373.1103.100.4.1.1.11ColumnptpClockPriority2read-createcurrentThis value is used by BMC algorithm to select the best master clock. This is used as a tiebreaker when the BMC failes to order the clock using ptpClockPriority…
1.3.6.1.4.1.3373.1103.100.4.1.1.12ColumnptpClockSlaveOnlyread-createcurrentConfiguring this value as true will make the clock to behave as slave clock. A boundary clock can not be a slave only clock.
1.3.6.1.4.1.3373.1103.100.4.1.1.13ColumnptpClockLocalPriorityread-createcurrentThis attribute is used in the alternate BMCA as a tie-breaker in the dataset comparison algorithm, in the event that all other previous attributes of the datas…
1.3.6.1.4.1.3373.1103.100.4.1.1.14ColumnptpClockRowStatusread-createcurrentRowStatus for creating the entries into this table. This object support only destroy and createAndGo values.
1.3.6.1.4.1.3373.1103.100.5NodeptpCurrentDataSet
1.3.6.1.4.1.3373.1103.100.5.1TableptpCurrentDataSetTablenot-accessiblecurrentTable of information about the PTP clock Current Datasets for all domains.
1.3.6.1.4.1.3373.1103.100.5.1.1RowptpCurrentDataSetEntrynot-accessiblecurrentContains synchronization information on a particular domain.
1.3.6.1.4.1.3373.1103.100.5.1.1.1ColumnptpCurrentStepsRemovedread-onlycurrentThis object specifies the distance measured by the number of Boundary clocks between the local clock and the Foreign master as indicated in the stepsRemoved fi…
1.3.6.1.4.1.3373.1103.100.5.1.1.2ColumnptpCurrentOffsetFromMasterread-onlycurrentThis object specifies the current clock dataset ClockOffset value. The value of the computation of the offset in time between a slave and a master clock.
1.3.6.1.4.1.3373.1103.100.5.1.1.3ColumnptpCurrentMeanPathDelayread-onlycurrentThis object specifies the current clock dataset MeanPathDelay value. The mean path delay between a pair of ports as measure by the delay request-response mecha…
1.3.6.1.4.1.3373.1103.100.6NodeptpParentDataSet
1.3.6.1.4.1.3373.1103.100.6.1TableptpParentDataSetTablenot-accessiblecurrentTable of information about the PTP clock Parent Datasets for all domains.
1.3.6.1.4.1.3373.1103.100.6.1.1RowptpParentDataSetEntrynot-accessiblecurrentContains parent clock information on a particular domain.
1.3.6.1.4.1.3373.1103.100.6.1.1.1ColumnptpParentClockIdentityread-onlycurrentThis is the clock identity of the port on the master that issues sync messages used in synchronizing this clock. The initial value of this field is the value o…
1.3.6.1.4.1.3373.1103.100.6.1.1.2ColumnptpParentPortNumberread-onlycurrentThis is the port number identity of the port on the master that issues sync message used in synchronizing this clock. Combination of ptpParentClockIdentity and…
1.3.6.1.4.1.3373.1103.100.6.1.1.3ColumnptpParentGMClockIdentityread-onlycurrentThis is the clock identity attribute of the grand master clock. The initial value is ptpClockIdentity.
1.3.6.1.4.1.3373.1103.100.6.1.1.4ColumnptpParentGMClockClassread-onlycurrentThis is the clock class of the grandmaster. The initialization value of this variable is ptpClockClass.
1.3.6.1.4.1.3373.1103.100.6.1.1.5ColumnptpParentGMClockAccuracyread-onlycurrentThis is the clock accuracy of the grandmaster. The initialization value of this variable is ptpClockAccuracy
1.3.6.1.4.1.3373.1103.100.6.1.1.6ColumnptpParentGMClockOffsetScaledLogVarianceread-onlycurrentThis is the offset scaled log variance of the grandmaster. The initialization value of this variable is ptpClockOffsetScaledLogVariance
1.3.6.1.4.1.3373.1103.100.6.1.1.7ColumnptpParentGMPriority1read-onlycurrentThis is the priority1 of the grandmaster clock. The initialization value of this variable is ptpClockPriority1
1.3.6.1.4.1.3373.1103.100.6.1.1.8ColumnptpParentGMPriority2read-onlycurrentThis is the priority2 of the grandmaster clock. The initialization value of this variable is ptpClockPriority2
1.3.6.1.4.1.3373.1103.100.7NodeptpTimePropertiesDataSet
1.3.6.1.4.1.3373.1103.100.7.1TableptpTimeDataSetTablenot-accessiblecurrentTable of information about the PTP clock Timeproperties Datasets for all domains.
1.3.6.1.4.1.3373.1103.100.7.1.1RowptpTimeDataSetEntrynot-accessiblecurrentContains parent Time properties information of the clock on a particular domain.
1.3.6.1.4.1.3373.1103.100.7.1.1.1ColumnptpTimeCurrentUTCOffsetread-onlycurrentIf systems epoch is the PTP epoch then this value indicates the offset in seconds between TAI and UTC.
1.3.6.1.4.1.3373.1103.100.7.1.1.2ColumnptpTimeCurrentUTCOffsetValidread-onlycurrentValue of this variable is TRUE if the ptpTimeCurrentUTCOffset is known to be correct.
1.3.6.1.4.1.3373.1103.100.7.1.1.3ColumnptpTimeLeap59read-onlycurrentIf the systems epoch is PTP epoch then TRUE value of this variable indicates that the last minute of the current UTC day contains 59 seconds.
1.3.6.1.4.1.3373.1103.100.7.1.1.4ColumnptpTimeLeap61read-onlycurrentIf the systems epoch is PTP epoch then TRUE value of this variable indicates that the last minute of the current UTC day contains 61 seconds.
1.3.6.1.4.1.3373.1103.100.7.1.1.5ColumnptpTimeTimeTraceableread-onlycurrentThis variable is TRUE if the timescale and value of ptpTimeCurrentUTCOffset are traceable to a primary reference otherwise, the value shall be FALSE.
1.3.6.1.4.1.3373.1103.100.7.1.1.6ColumnptpTimeFrequencyTraceableread-onlycurrentThis variable is TRUE if the frequecy determining the timescale is traceable to a primary reference otherwise, the value shall be FALSE.
1.3.6.1.4.1.3373.1103.100.7.1.1.7ColumnptpTimescaleread-onlycurrentThis variable is TRUE if the clock timescale of the grandmaster clock is PTP otherwise, the value shall be FALSE.
1.3.6.1.4.1.3373.1103.100.7.1.1.8ColumnptpTimeTimeSourceread-onlycurrentThis is the source of time used by the grandmaster clock. If the time source is known at the time of initialization then the value will be set to that otherwis…
1.3.6.1.4.1.3373.1103.100.8NodeptpPortDataSet
1.3.6.1.4.1.3373.1103.100.8.1TableptpPortDataSetTablenot-accessiblecurrentTable Contains PTP configuration information for a particular port of boundary or an ordinary clock
1.3.6.1.4.1.3373.1103.100.8.1.1RowptpPortDataSetEntrynot-accessiblecurrentContains PTP configuration information for a particular port. Valid ptpPortIfIndex need to be given to make this entry active. Where not otherwise specified, e…
1.3.6.1.4.1.3373.1103.100.8.1.1.1ColumnptpPortIndexread-onlycurrentThe index value used to identify the port component on the device. The value of this object is used as a port index to the ptpPortConfigDataSetTable.
1.3.6.1.4.1.3373.1103.100.8.1.1.2ColumnptpPortClockIdentityread-onlycurrentThis is the clock Identity of the port
1.3.6.1.4.1.3373.1103.100.8.1.1.3ColumnptpPortIfIndexread-createcurrentThis is the index in ifTable of this port. This object can't be modified.
1.3.6.1.4.1.3373.1103.100.8.1.1.4ColumnptpPortStaticRoleread-createcurrentRole of this port. This object forces the role of the port if ptpStaticPortRole is true.
1.3.6.1.4.1.3373.1103.100.8.1.1.5ColumnptpPortAdminStatusread-createcurrentAdministrive status of the port. The value down turns off the PTP protocol on the ethernet port.
1.3.6.1.4.1.3373.1103.100.8.1.1.6ColumnptpPortStateread-onlycurrentThis denotes the PTP State of the PTP port as computed by the PTP State event machine. initializing: While a port is in the INITIALIZING state, the port initia…
1.3.6.1.4.1.3373.1103.100.8.1.1.7ColumnptpPortMinDelayReqIntervalread-createcurrentThis is the log to the base 2 of the delay request interval in seconds. This speifies the time to the members devices to send delay request messages when the p…
1.3.6.1.4.1.3373.1103.100.8.1.1.8ColumnptpPortLogAnnounceIntervalread-createcurrentThis is the log to the base 2 of the mean Announce message interval in seconds.
1.3.6.1.4.1.3373.1103.100.8.1.1.9ColumnptpPortAnnounceReceiptTimeoutread-createcurrentThis is the Announce receipt time out value. This should be an integral multiple of announce interval in seconds
1.3.6.1.4.1.3373.1103.100.8.1.1.10ColumnptpPortSyncIntervalread-createcurrentThis is the logarithm to the base 2 of the sync message interval in seconds
1.3.6.1.4.1.3373.1103.100.8.1.1.11ColumnptpPortDelayMechanismread-onlycurrentThis indicates the propagation delay measuring option used by the port in computing meanpathDelay.
1.3.6.1.4.1.3373.1103.100.8.1.1.12ColumnptpPortVersionNumberread-onlycurrentThis indicates the PTP version in use on the port.
1.3.6.1.4.1.3373.1103.100.8.1.1.13ColumnptpPortNotSlaveread-createcurrentThis attribute is used in the alternate BMCA to prevent that a port can be placed in the SLAVE state.
1.3.6.1.4.1.3373.1103.100.8.1.1.14ColumnptpPortLocalPriorityread-createcurrentThis attribute is used in the alternate BMCA as a tie-breaker in the dataset comparison algorithm, in the event that all other previous attributes of the datas…
1.3.6.1.4.1.3373.1103.100.8.1.1.15ColumnptpPortDestMacAddressread-createcurrentThis attribute is used in to select the destination MAC address inserted in the outgoing packets: forwardable: 01-1B-19-00-00-00 nonForwardable: 01-80-C2-00-00…
1.3.6.1.4.1.3373.1103.100.8.1.1.16ColumnptpPortTxAsymmetryCompensationread-createcurrentThis attribute is used to compensate in nanoseconds the asymmetric delay. It works in TX direction.
1.3.6.1.4.1.3373.1103.100.8.1.1.17ColumnptpPortRxAsymmetryCompensationread-createcurrentThis attribute is used to compensate in nanoseconds the asymmetric delay. It works in RX direction.
1.3.6.1.4.1.3373.1103.100.8.1.1.18ColumnptpPortRowStatusread-createcurrentRowStatus for creating the entries into this table. This object can't be modified.
1.3.6.1.4.1.3373.1103.100.8.2TableptpPortAlarmTablenot-accessiblecurrentTable Contains PTP alarm information for a particular port of boundary or an ordinary clock.
1.3.6.1.4.1.3373.1103.100.8.2.1RowptpPortAlarmEntrynot-accessiblecurrentContains PTP alarm information for a particular port.
1.3.6.1.4.1.3373.1103.100.8.2.1.1ColumnptpPortFaultyAlarmread-onlycurrentThis alarm is raised when ptpPortState is set to faulty(2).
1.3.6.1.4.1.3373.1103.100.8.2.1.2ColumnptpPortInitializingAlarmread-onlycurrentThis alarm is raised when ptpPortState is set to initializing(1).
1.3.6.1.4.1.3373.1103.100.8.2.1.3ColumnptpPortUncalibratedAlarmread-onlycurrentThis alarm is raised when ptpPortState is set to uncalibrated(8).
1.3.6.1.4.1.3373.1103.100.8.2.1.4ColumnptpPortListeningAlarmread-onlycurrentThis alarm is raised when ptpPortState is set to listening(4).
1.3.6.1.4.1.3373.1103.100.8.2.1.5ColumnptpPortActiveStatusread-onlycurrentThis alarm is raised when ptpPortState is set to slave(9).
1.3.6.1.4.1.3373.1103.100.8.3TableptpPortRadioAlarmTablenot-accessiblecurrentTable Contains PTP alarm information for a radio port of boundary or an ordinary clock.
1.3.6.1.4.1.3373.1103.100.8.3.1RowptpPortRadioAlarmEntrynot-accessiblecurrentContains PTP alarm information for a radio port.
1.3.6.1.4.1.3373.1103.100.8.3.1.1ColumnptpPortRadioCapacityAlarmread-onlycurrentThis alarm is raised when the capacity of a radio link is not big enough to transport PTP packets.
1.3.6.1.4.1.3373.1103.100.8.4ScalarptpPortFaultyAlarmSeverityCoderead-writecurrentThis object defines the severity associated to ptpPortFaultyAlarm and enables or disables the sending of the SNMP Trap on the alarm status transition.
1.3.6.1.4.1.3373.1103.100.8.5ScalarptpPortInitializingAlarmSeverityCoderead-writecurrentThis object defines the severity associated to ptpPortInitializingAlarm and enables or disables the sending of the SNMP Trap on the alarm status transition.
1.3.6.1.4.1.3373.1103.100.8.6ScalarptpPortUncalibratedAlarmSeverityCoderead-writecurrentThis object defines the severity associated to ptpPortUncalibratedAlarm and enables or disables the sending of the SNMP Trap on the alarm status transition.
1.3.6.1.4.1.3373.1103.100.8.7ScalarptpPortListeningAlarmSeverityCoderead-writecurrentThis object defines the severity associated to ptpPortListeningAlarm and enables or disables the sending of the SNMP Trap on the alarm status transition.
1.3.6.1.4.1.3373.1103.100.8.8ScalarptpPortActiveStatusSeverityCoderead-writecurrentThis object enables or disables the sending of the SNMP Trap on ptpPortActiveStatus transition.
1.3.6.1.4.1.3373.1103.100.8.9ScalarptpPortRadioCapacityAlarmSeverityCoderead-writecurrentThis object enables or disables the sending of the SNMP Trap on ptpPortRadioCapacityAlarm transition.
1.3.6.1.4.1.3373.1103.100.9NodeptpClockPPSDataSet
1.3.6.1.4.1.3373.1103.100.9.1TableptpClockPPSDataSetTablenot-accessiblecurrentTable of information about the PTP clock PPS and ToD properties.
1.3.6.1.4.1.3373.1103.100.9.1.1RowptpClockPPSDataSetEntrynot-accessiblecurrentContains PPS and ToD properties information of the specific domain and clock on a specific PPS socket.
1.3.6.1.4.1.3373.1103.100.9.1.1.1ColumnptpClockPPSInstanceIndexread-writecurrentThis object specifies the id of PPS interface socket. It represents the id of ToD interface socket too.
1.3.6.1.4.1.3373.1103.100.9.1.1.2ColumnptpClockPPSInstanceCapabilityread-onlycurrentThis object is a bitmap and each bit represents a specific capability of the PPS or ToD interface. Bit 0 : 1 = the interface can be used either in input or in …
1.3.6.1.4.1.3373.1103.100.9.1.1.3ColumnptpClockPPSDirectionread-writecurrentThis object specifies the direction (input or output) of PPS signal and ToD data
1.3.6.1.4.1.3373.1103.100.9.1.1.4ColumnptpClockPPSLabelread-onlycurrentThis object specifies the label as appears near the PPS signal socket
1.3.6.1.4.1.3373.1103.100.9.1.1.5ColumnptpClockPPSAdminStatusread-writecurrentThis object is the administrive status of PPS interface and specifies whether the node is enabled for PTP input/output clocking using the PPS interface.
1.3.6.1.4.1.3373.1103.100.9.1.1.6ColumnptpClockPPSOffsetEnabledread-writecurrentThis object specifies whether an offset is configured in order to compensate for a known phase error such as network asymmetry.
1.3.6.1.4.1.3373.1103.100.9.1.1.7ColumnptpClockPPSOffsetValueread-writecurrentThis object specifies the fixed offset signed value in nanoseconds configured to be added for the PPS output or input.
1.3.6.1.4.1.3373.1103.100.9.1.1.8ColumnptpClockToDLabelread-onlycurrentThis object specifies the label as appears near the ToD socket
1.3.6.1.4.1.3373.1103.100.9.1.1.9ColumnptpClockToDAdminStatusread-writecurrentThis object is the administrive status of PPS interface and specifies whether the ToD interface is enabled.
1.3.6.1.4.1.3373.1103.100.9.1.1.10ColumnptpClockToDDelayread-writecurrentThis object specifies microseconds of delay between PPS edge and ToD data emitted, used only in output direction.
1.3.6.1.4.1.3373.1103.100.9.1.1.11ColumnptpClockToDBaudrateread-writecurrentThis object specifies the Baudrate of ToD signal in input or output direction.
1.3.6.1.4.1.3373.1103.100.9.1.1.12ColumnptpClockToDFormatread-writecurrentThis object specifies the format of ToD signal in input or output direction.
1.3.6.1.4.1.3373.1103.100.10NodeptpRadioAsymmetryDataSet
1.3.6.1.4.1.3373.1103.100.10.1TableptpRadioAsymmetryDataSetTablenot-accessiblecurrentTable contains delay offset for asymmetries compensation for the Radio unit.
1.3.6.1.4.1.3373.1103.100.10.1.1RowptpRadioAsymmetryDataSetEntrynot-accessiblecurrentEach ntry contains delay offset for asymmetries compensation for a specific Radio unit.
1.3.6.1.4.1.3373.1103.100.10.1.1.1ColumnptpRadioBrIndexread-onlycurrentThis is the index in radioTable of this unit. This object can't be modified.
1.3.6.1.4.1.3373.1103.100.10.1.1.2ColumnptpRadioOffsetread-writecurrentThis object is an offset in nanoseconds for asymmetry compensation and can have both positive and negative values.
Type Definitions
NameSyntaxStatusDescription
ClockDomainTypeUnsigned32 (24..43)currentThe Domain is identified by an integer, the domainNumber, in the range of 0 to 255. An integer value that is used to assign each PTP device to a particular domain. The following values define the valid domains. [1] Sect…
ClockInstanceTypeUnsigned32 (0..255)currentThe instance of the Clock of a given clock type in a given domain.
ClockMechanismTypeINTEGER { e2e(1) }currentThe clock type based on whether End to End or peer to peer mechanisms are used. The mechanism used to calculate the Mean Path Delay as indicated in Table 9 of IEEE 1588-2008. Delay mechanism Value(hex) Specification E2E…
ClockPortNumberUnsigned32 (0..65535)currentAn index identifying a specific Precision Time Protocol (PTP) port on a PTP node.
ClockPortStateINTEGER { initializing(1), faulty(2), disabled(3), listening(4), preMaster(5), master(6), passive(7), uncalibrated(8), slave(9) }currentThis is the value of the current state of the protocol engine associated with this port. Port state Value Description initializing 1 In this state a port initializes its data sets, hardware, and communication facilities…
ClockPPSInstanceTypeUnsigned32 (0..255)currentThe instance of the PPS (and ToD) socket.
ClockProfileTypeINTEGER { default(1), telecom(2), vendorspecific(3) }currentClock Profile used. A profile is the set of allowed Precision Time Protocol (PTP) features applicable to a device.
ClockQualityAccuracyTypeINTEGER { reserved00(1), nanoSecond25(32), nanoSecond100(33), nanoSecond250(34), microSec1(35), microSec2dot5(36), microSec10(37), microSec25(38), microSec100(39), microSec250(40), milliSec1(41), milliSec2dot5(42), milliSec10(43), milliSec25(44), milliSec100(45), milliSec250(46), second1(47), second10(48), secondGreater10(49), unknown(254), reserved255(255) }currentThe ClockQuality as specified in section 5.3.7, 7.6.2.5 and Table 6 of [1]. The following values are not represented in the enumerated values. 0x01-0x1F Reserved 0x32-0x7F Reserved It is important to note that section 7…
ClockQualityClassTypeINTEGER (0..255)currentThe ClockQuality as specified in section 5.3.7, 7.6.2.4 and Table 5 of [1]. Value Description 0 Reserved to enable compatibility with future versions. 1-5 Reserved 6 Shall designate a clock that is synchronized to a pri…
ClockStateTypeINTEGER { freerun(1), acquiring(2), locked(3), holdoverInSpec(4), holdoverOutOfSpec(5) }currentThe clock state returned by PTP engine. Clock State Value Description Freerun state 1 The PTP clock has never been synchronized to a time source and is not in the process of synchronizing to a time source. As it relates…
ClockTimeIntervalOCTET STRING (SIZE (1..255))currentThis textual convention corresponds to the TimeInterval structure indicated in section 5.3.2 of [1]. It will be presented in the form of a character array. The TimeInterval type represents time intervals. struct TimeInt…
ClockTimeSourceTypeINTEGER { atomicClock(16), gps(32), terrestrialRadio(48), ptp(64), ntp(80), handSet(96), other(144), internalOscillator(160), reserved(255) }currentThe ClockQuality as specified in section 5.3.7, 7.6.2.6 and Table 7 of [1]. The following values are not represented in the enumerated values. 0xF0-0xFE For use by alternate PTP profiles 0xFF Reserved It is important to…
ClockTypeINTEGER { boundaryClock(2) }currentThe clock types as defined in the MIB module description.
PtpClockToDFormatTypeINTEGER { telecomTimeEvent(1), telecomTimeAnnounce(2), telecomGNSSstatus(3), nmeazda(4), iso8601(5), ntp(6), ublox(7), chinaMobile(8), chinaTelecom(9), bcm(10), bcmts(11) }current