MIB Viewer

SIAE-SENSOR-TEMP-MIB

25 objects
Management information for equipment heat.
OIDNameAccessStatusDescription
1.3.6.1.4.1.3373.1103.77IdentitysensorTempManagement information for equipment heat.
1.3.6.1.4.1.3373.1103.77.1ScalarsensorTempMibVersionread-onlycurrentNumerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.0…
1.3.6.1.4.1.3373.1103.77.2TablesensorTempTablenot-accessiblecurrentTable with sensorTemp device entries
1.3.6.1.4.1.3373.1103.77.2.1RowsensorTempEntrynot-accessiblecurrentTemperature Sensor entry
1.3.6.1.4.1.3373.1103.77.2.1.1ColumnsensorTempIndexread-onlycurrentTemperature Sensor index.
1.3.6.1.4.1.3373.1103.77.2.1.2ColumnsensorTempValueread-onlycurrentValue of the temperature (in Celsius).
1.3.6.1.4.1.3373.1103.77.2.1.3ColumnsensorTempThreshold1read-onlycurrentThis object can not be modified. It reports the temperature threshold 1. When sensorTempValue exceeds this value sensorTempStatus1 becomes Active. When thresho…
1.3.6.1.4.1.3373.1103.77.2.1.4ColumnsensorTempThreshold2read-onlycurrentThis object can not be modified. It reports the temperature threshold 2. When sensorTempValue exceeds this value sensorTempStatus2 becomes Active. When thresho…
1.3.6.1.4.1.3373.1103.77.2.1.5ColumnsensorTempHysteresis1read-onlycurrentThis object can not be modified. It reports the temperature hysteresis 1. When sensorTempStatus1 is Active it represents the value under which returns cleared.
1.3.6.1.4.1.3373.1103.77.2.1.6ColumnsensorTempHysteresis2read-onlycurrentThis object can not be modified. It reports the temperature hysteresis 2. When sensorTempStatus1 is Active it represents the value under which returns cleared.
1.3.6.1.4.1.3373.1103.77.2.1.7ColumnsensorTempStatus1read-onlycurrentThis object is used to manage temperature related to sensorTempThreshold1. Values mean: cleared: sensorTempValue is lower than threshold1 active: sensorTempVal…
1.3.6.1.4.1.3373.1103.77.2.1.8ColumnsensorTempStatus2read-onlycurrentThis object is used to manage temperature related to sensorTempThreshold2. Values mean: cleared: sensorTempValue is lower than threshold2 active: sensorTempVal…
1.3.6.1.4.1.3373.1103.77.2.1.9ColumnsensorTempLabelread-onlycurrentA textual string containing information on sensorTemp sensor.
1.3.6.1.4.1.3373.1103.77.3ScalarsensorTempAlarmThreshold1read-onlycurrentThis object is used to notiy alarm if at least one entry in the sensorTemp table has got sensorTempStatus1 alarmed.
1.3.6.1.4.1.3373.1103.77.4ScalarsensorTempAlarmThreshold2read-onlycurrentThis object is used to notiy alarm if at least one entry in the sensorTemp table has got sensorTempStatus2 alarmed.
1.3.6.1.4.1.3373.1103.77.5ScalarsensorTempAlarmThreshold1Severityread-writecurrentThis object is used to change severity of sensorTempAlarmThreshold1.
1.3.6.1.4.1.3373.1103.77.6ScalarsensorTempAlarmThreshold2Severityread-writecurrentThis object is used to change severity of sensorTempAlarmThreshold2.
1.3.6.1.4.1.3373.1103.77.7TablesensorTempMonitorTablenot-accessiblecurrentTable with sensorTempMonitor entries
1.3.6.1.4.1.3373.1103.77.7.1RowsensorTempMonitorEntrynot-accessiblecurrentTemperature Sensor Monitor entry
1.3.6.1.4.1.3373.1103.77.7.1.1ColumnsensorTempMonitorAdminStatusread-writecurrentThe desired state of the temperatuure monitor. When a managed system initializes, all the temperature monitors start with sensorTempMonitorAdminStatus in the d…
1.3.6.1.4.1.3373.1103.77.7.1.2ColumnsensorTempMonitorOperStatusread-onlycurrentThe current state of the temperatuure monitor. Usually this object report the same value of sensorTempMonitorAdminStatus. When there is some problem related to…
1.3.6.1.4.1.3373.1103.77.7.1.3ColumnsensorTempMonitorMinTempread-onlycurrentThe minimum value of the temperature measured in the last actual 900 seconds. The value is expressed in degrees Celsius.
1.3.6.1.4.1.3373.1103.77.7.1.4ColumnsensorTempMonitorMaxTempread-onlycurrentThe maximum value of the temperature measured in the last actual 900 seconds. The value is expressed in degrees Celsius.
1.3.6.1.4.1.3373.1103.77.7.1.5ColumnsensorTempMonitorAverageTempread-onlycurrentThe average value of the temperature measured in the last actual 900 seconds. The value is expressed in tenth of degrees Celsius.
1.3.6.1.4.1.3373.1103.77.8ScalarsensorTempMonitorSystemControlread-writecurrentThe administrative system control status requested by management for the TEMP-MONITOR feature. The value 'start'(1) indicates that TEMP-MONITOR should be suppo…