SIAE-SENSOR-TEMP-MIB
25 objects
Management information for equipment heat.
Imported Objects
| SIAE-ALARM-MIB | AlarmSeverityCode AlarmStatus |
| SIAE-TREE-MIB | siaeMib |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY OBJECT-TYPE |
| SNMPv2-TC | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3373.1103.77 | IdentitysensorTemp | Management information for equipment heat. | ||
| 1.3.6.1.4.1.3373.1103.77.1 | ScalarsensorTempMibVersion | read-only | current | Numerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.0… |
| 1.3.6.1.4.1.3373.1103.77.2 | TablesensorTempTable | not-accessible | current | Table with sensorTemp device entries |
| 1.3.6.1.4.1.3373.1103.77.2.1 | RowsensorTempEntry | not-accessible | current | Temperature Sensor entry |
| 1.3.6.1.4.1.3373.1103.77.2.1.1 | ColumnsensorTempIndex | read-only | current | Temperature Sensor index. |
| 1.3.6.1.4.1.3373.1103.77.2.1.2 | ColumnsensorTempValue | read-only | current | Value of the temperature (in Celsius). |
| 1.3.6.1.4.1.3373.1103.77.2.1.3 | ColumnsensorTempThreshold1 | read-only | current | This object can not be modified. It reports the temperature threshold 1. When sensorTempValue exceeds this value sensorTempStatus1 becomes Active. When thresho… |
| 1.3.6.1.4.1.3373.1103.77.2.1.4 | ColumnsensorTempThreshold2 | read-only | current | This object can not be modified. It reports the temperature threshold 2. When sensorTempValue exceeds this value sensorTempStatus2 becomes Active. When thresho… |
| 1.3.6.1.4.1.3373.1103.77.2.1.5 | ColumnsensorTempHysteresis1 | read-only | current | This object can not be modified. It reports the temperature hysteresis 1. When sensorTempStatus1 is Active it represents the value under which returns cleared. |
| 1.3.6.1.4.1.3373.1103.77.2.1.6 | ColumnsensorTempHysteresis2 | read-only | current | This object can not be modified. It reports the temperature hysteresis 2. When sensorTempStatus1 is Active it represents the value under which returns cleared. |
| 1.3.6.1.4.1.3373.1103.77.2.1.7 | ColumnsensorTempStatus1 | read-only | current | This object is used to manage temperature related to sensorTempThreshold1. Values mean: cleared: sensorTempValue is lower than threshold1 active: sensorTempVal… |
| 1.3.6.1.4.1.3373.1103.77.2.1.8 | ColumnsensorTempStatus2 | read-only | current | This object is used to manage temperature related to sensorTempThreshold2. Values mean: cleared: sensorTempValue is lower than threshold2 active: sensorTempVal… |
| 1.3.6.1.4.1.3373.1103.77.2.1.9 | ColumnsensorTempLabel | read-only | current | A textual string containing information on sensorTemp sensor. |
| 1.3.6.1.4.1.3373.1103.77.3 | ScalarsensorTempAlarmThreshold1 | read-only | current | This object is used to notiy alarm if at least one entry in the sensorTemp table has got sensorTempStatus1 alarmed. |
| 1.3.6.1.4.1.3373.1103.77.4 | ScalarsensorTempAlarmThreshold2 | read-only | current | This object is used to notiy alarm if at least one entry in the sensorTemp table has got sensorTempStatus2 alarmed. |
| 1.3.6.1.4.1.3373.1103.77.5 | ScalarsensorTempAlarmThreshold1Severity | read-write | current | This object is used to change severity of sensorTempAlarmThreshold1. |
| 1.3.6.1.4.1.3373.1103.77.6 | ScalarsensorTempAlarmThreshold2Severity | read-write | current | This object is used to change severity of sensorTempAlarmThreshold2. |
| 1.3.6.1.4.1.3373.1103.77.7 | TablesensorTempMonitorTable | not-accessible | current | Table with sensorTempMonitor entries |
| 1.3.6.1.4.1.3373.1103.77.7.1 | RowsensorTempMonitorEntry | not-accessible | current | Temperature Sensor Monitor entry |
| 1.3.6.1.4.1.3373.1103.77.7.1.1 | ColumnsensorTempMonitorAdminStatus | read-write | current | The desired state of the temperatuure monitor. When a managed system initializes, all the temperature monitors start with sensorTempMonitorAdminStatus in the d… |
| 1.3.6.1.4.1.3373.1103.77.7.1.2 | ColumnsensorTempMonitorOperStatus | read-only | current | The current state of the temperatuure monitor. Usually this object report the same value of sensorTempMonitorAdminStatus. When there is some problem related to… |
| 1.3.6.1.4.1.3373.1103.77.7.1.3 | ColumnsensorTempMonitorMinTemp | read-only | current | The minimum value of the temperature measured in the last actual 900 seconds. The value is expressed in degrees Celsius. |
| 1.3.6.1.4.1.3373.1103.77.7.1.4 | ColumnsensorTempMonitorMaxTemp | read-only | current | The maximum value of the temperature measured in the last actual 900 seconds. The value is expressed in degrees Celsius. |
| 1.3.6.1.4.1.3373.1103.77.7.1.5 | ColumnsensorTempMonitorAverageTemp | read-only | current | The average value of the temperature measured in the last actual 900 seconds. The value is expressed in tenth of degrees Celsius. |
| 1.3.6.1.4.1.3373.1103.77.8 | ScalarsensorTempMonitorSystemControl | read-write | current | The administrative system control status requested by management for the TEMP-MONITOR feature. The value 'start'(1) indicates that TEMP-MONITOR should be suppo… |