SIAE-SFP-MIB

56 objects
This MIB contains objects & alarms for a SFP (Small Form-Factor Pluggable) module. Reference documentation: 1) Small Form-factor Pluggable (SFP) Transceiver MultiSource Agreement (MSA) 2) Finisar's Application Note AN-2030, Rev. D. 3) SFF 8472 - Diagnostic Monitoring Interface for Optical Transceivers Rev 12.2 November 21, 2014 4) SFF 8024 - SFF Cross Reference to Industry Products Rev 4.0 June 27, 2016
Imported Objects
SIAE-ALARM-MIBAlarmSeverityCode AlarmStatus
SIAE-TREE-MIBsiaeMib
SNMPv2-SMIInteger32 MODULE-IDENTITY OBJECT-TYPE
SNMPv2-TCDisplayString TEXTUAL-CONVENTION TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.3373.1103.74IdentitysfpThis MIB contains objects & alarms for a SFP (Small Form-Factor Pluggable) module. Reference documentation: 1) Small Form-factor Pluggable (SFP) Transceiver Mu…
1.3.6.1.4.1.3373.1103.74.1ScalarsfpMibVersionread-onlycurrentNumerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.0…
1.3.6.1.4.1.3373.1103.74.2TablesfpSerialIdTablenot-accessiblecurrentEach SFP contains a 95+32 byte block of ID data fields. This table contains the items found in this data block. Fields in this data block is filled in by the S…
1.3.6.1.4.1.3373.1103.74.2.1RowsfpSerialIdEntrynot-accessiblecurrentSFP module record.
1.3.6.1.4.1.3373.1103.74.2.1.1ColumnsfpModuleIdread-onlycurrentThis index identifies a unique SFP module in the system
1.3.6.1.4.1.3373.1103.74.2.1.2ColumnsfpSerialIdValidread-onlycurrentWhen false the SFP data in this table is not valid. This will be set to False if the SFP module is not installed or if the EEPROM check code is wrong. The data…
1.3.6.1.4.1.3373.1103.74.2.1.3ColumnsfpVendorNameread-onlycurrentThe SFP vendor name. Located at I2C address 0xa0, bytes: 20 - 35
1.3.6.1.4.1.3373.1103.74.2.1.4ColumnsfpVendorPartNumberread-onlycurrentThe SFP vendor part number. Located at I2C address 0xa0, bytes: 40 - 55
1.3.6.1.4.1.3373.1103.74.2.1.5ColumnsfpVendorRevread-onlycurrentThe SFP vendor's product revision number. Located at I2C address 0xa0, bytes: 56 - 59
1.3.6.1.4.1.3373.1103.74.2.1.6ColumnsfpVendorSNread-onlycurrentThe SFP vendor serial number. Located at I2C address 0xa0, bytes: 68 - 83
1.3.6.1.4.1.3373.1103.74.2.1.7ColumnsfpVendorDateCoderead-onlycurrentThe SFP vendor date code. Format: YYMMDDLL - YY: year, 00 = 2000 - MM: month, 01 = January - DD_ day, 01 to 31 - LL: vendor lot code, or blank. Located at I2C …
1.3.6.1.4.1.3373.1103.74.2.1.8ColumnsfpDiagMonitorCoderead-onlycurrentThis indicates which type of diagnostic monitoring is implemented (if any) in the SFP. -bit 7: = 0 legacy diagnostic implementations (should be 0) -bit 6: = 1 …
1.3.6.1.4.1.3373.1103.74.2.1.9ColumnsfpEnhancedOptionsCoderead-onlycurrentThis indicates which optional enhanced features are implemented (if any) in the SFP. Located at I2C address 0xa0, byte: 93
1.3.6.1.4.1.3373.1103.74.2.1.10ColumnsfpOptionsread-onlycurrentImplemented transceiver options: -bit 5: = 1 RATE_SELECT implemented. -bit 4: = 1 TX_DISABLE implemented -bit 3: = 1 TX_FAULT implemented -bit 2: = 1 LOS Imple…
1.3.6.1.4.1.3373.1103.74.2.1.11ColumnsfpFibreChannelMediaread-onlycurrentFiber Channel transmission media. Located at I2C address 0xa0, byte: 9
1.3.6.1.4.1.3373.1103.74.2.1.12ColumnsfpComplianceread-onlycurrentElectronic or optical interfaces that are supported by the transceiver. Located at I2C address 0xa0, bytes: 4,5 & 6
1.3.6.1.4.1.3373.1103.74.2.1.13ColumnsfpWavelengthread-onlycurrentNominal transmiter output wavelength at room temperature. Units are in nm (nanometers). Located at I2C address 0xa0, bytes: 60 & 61 (endianess: big)
1.3.6.1.4.1.3373.1103.74.2.1.14ColumnsfpNominalBitRateread-onlycurrentNominal bit rate (in megabit per second) supported from this SFP module rouded to the nearest 100 megabits per second. Located at I2C address 0xa0, byte: 12
1.3.6.1.4.1.3373.1103.74.2.1.15ColumnsfpLinkLength9uread-onlycurrentLink length (in meters) supported from this SFP module while operating in compliance with the applicable standards using single mode fiber. A value of zero mea…
1.3.6.1.4.1.3373.1103.74.2.1.16ColumnsfpLinkLength50uread-onlycurrentLink length (in meters) supported from this SFP module while operating in compliance with the applicable standards using 50 micron multi-mode fiber. A value of…
1.3.6.1.4.1.3373.1103.74.2.1.17ColumnsfpLinkLength62u5read-onlycurrentLink length (in meters) supported from this SFP module while operating in compliance with the applicable standards using 62.5 micron multi-mode fiber. A value …
1.3.6.1.4.1.3373.1103.74.2.1.18ColumnsfpLinkLengthCopperread-onlycurrentLink length (in meters) supported from this SFP module while operating in compliance with the applicable standards using copper cable. A value of zero means th…
1.3.6.1.4.1.3373.1103.74.2.1.19ColumnsfpLabelread-onlycurrentThis is an ASCII string that identifies this SFP in the system.
1.3.6.1.4.1.3373.1103.74.2.1.20ColumnsfpFailAlarmread-onlycurrentSFP Module fail (module missing included)
1.3.6.1.4.1.3373.1103.74.6ScalarsfpFailAlarmSeverityCoderead-writecurrentDefines the severity associated to the sfpFailAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.74.7TablesfpDiagnosticTablenot-accessiblecurrentEach SFP may contain a 256 byte block of diagnostic data fields. This table contains the items found in this data block. The data block is located at I2C addre…
1.3.6.1.4.1.3373.1103.74.7.1RowsfpDiagnosticEntrynot-accessiblecurrentThis describes a row in the diagnostic table.
1.3.6.1.4.1.3373.1103.74.7.1.1ColumnsfpDiagnosticValidread-onlycurrentif False, then the SFP data in this table is not valid. This will be set to False if the SFP module is not installed, or if the I/O card that contains the SFP …
1.3.6.1.4.1.3373.1103.74.7.1.2ColumnsfpLOSPinOutread-onlycurrentThis contains the T/F state of the SFP LOS (output) pin. It is True if the SFP has detected Loss-Of-Signal. located at I2c address 0xa2, address: 110, mask 0x02
1.3.6.1.4.1.3373.1103.74.7.1.3ColumnsfpTxFaultPinOutread-onlycurrentThis contains the T/F state of the SFP Tx Fault (output) pin. It is True if the SFP has detected a Tx fault condition. located at I2C address 0xa2, Byte 110, m…
1.3.6.1.4.1.3373.1103.74.7.1.4ColumnsfpRateSelectPinInread-onlycurrentThis contains the T/F state of the SFP RX Rate Select (input) pin. This function is not implemented on Finisar SFPs. located at I2C address 0xa2, Byte 110, mas…
1.3.6.1.4.1.3373.1103.74.7.1.5ColumnsfpTxDisablePinInread-onlycurrentThis contains the T/F state of the SFP TX Disable (input) pin. located at I2C address 0xa2, Byte 110, mask 0x80
1.3.6.1.4.1.3373.1103.74.7.1.6ColumnsfpTemperatureread-onlycurrentThis contains the internal temperature of the SFP in tehnth of Celsius degrees. Range is from -128.0C to +128.0C, but is only valid from -40.0C to +125.0C with…
1.3.6.1.4.1.3373.1103.74.7.1.7ColumnsfpVoltageread-onlycurrentThis contains the internally measured SFP supply voltage (Vcc). Units are in milliVolts (3210 = 3.21V). Range is 0 to 6.554V. Located at I2C address 0xa2, Byte…
1.3.6.1.4.1.3373.1103.74.7.1.8ColumnsfpTxBiasread-onlycurrentThis contains the internally measured SFP TX laser bias current. Units are in microAmps, and range from 0 to 131000uA (131mA). Located at I2C address 0xa2, Byt…
1.3.6.1.4.1.3373.1103.74.7.1.9ColumnsfpTxPowerread-onlycurrentThis contains the internally measured TX output power. Units are in uW (micro Watts), and range from 0 to 6554uW (6.535mW). This value is not valid if the tran…
1.3.6.1.4.1.3373.1103.74.7.1.10ColumnsfpRxPowerread-onlycurrentThis contains the internally measured RX optical power. Units are in uW (micro Watts), and range from 0 to 6554uW (6.535mW). Located at I2C address 0xa2, Bytes…
1.3.6.1.4.1.3373.1103.74.7.1.11ColumnsfpInternalAlarmsread-onlycurrentThis contains the state of the SFP internal alarm register. A bit is set for each alarm that is active. located at I2C address 0xa2, Byte 112 & 113 (MSB, LSB) …
1.3.6.1.4.1.3373.1103.74.7.1.12ColumnsfpInternalWarningsread-onlycurrentThis contains the state of the SFP internal warning register. A bit is set for each warning that is active. located at I2C address 0xa2, Byte 116 & 117 (MSB, L…
1.3.6.1.4.1.3373.1103.74.10TablesfpAlarmTablenot-accessiblecurrentThis table contains the SFP alarm and warning threshold values.
1.3.6.1.4.1.3373.1103.74.10.1RowsfpAlarmEntrynot-accessiblecurrentAn entry into the Threshold table.
1.3.6.1.4.1.3373.1103.74.10.1.1ColumnsfpPhysicalQuantityread-onlycurrentMeasured physical quantity. Units of temperature are tenth of Celsius degrres, units of Power supply voltage (Vcc) are microVolts, units of Tx laser bias curre…
1.3.6.1.4.1.3373.1103.74.10.1.2ColumnsfpThresholdHighAlarmread-onlycurrentA reading at or above this temperature will trigger a high measured physical quantity alarm.
1.3.6.1.4.1.3373.1103.74.10.1.3ColumnsfpThresholdHighWarningread-onlycurrentA reading at or above this temperature will trigger a high measured physical quantity warning.
1.3.6.1.4.1.3373.1103.74.10.1.4ColumnsfpThresholdLowAlarmread-onlycurrentA reading at or above this temperature will trigger a low measured physical quantity alarm.
1.3.6.1.4.1.3373.1103.74.10.1.5ColumnsfpThresholdLowWarningread-onlycurrentA reading at or above this temperature will trigger a low measured physical quantity warning.
1.3.6.1.4.1.3373.1103.74.10.1.6ColumnsfpHighAlarmread-onlycurrentMeasured physical quantity has crossed sfpThresholdHighAlarm.
1.3.6.1.4.1.3373.1103.74.10.1.7ColumnsfpHighWarningAlarmread-onlycurrentMeasured physical quantity has crossed sfpThresholdHighWarning.
1.3.6.1.4.1.3373.1103.74.10.1.8ColumnsfpLowAlarmread-onlycurrentMeasured physical quantity has crossed sfpThresholdLowAlarm.
1.3.6.1.4.1.3373.1103.74.10.1.9ColumnsfpLowWarningAlarmread-onlycurrentMeasured physical quantity has crossed sfpThresholdLowWarning.
1.3.6.1.4.1.3373.1103.74.11ScalarsfpHighAlarmSeverityCoderead-writecurrentDefines the severity associated to the sfpHighAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.74.12ScalarsfpHighWarningAlarmSeverityCoderead-writecurrentDefines the severity associated to the sfpHighWarningAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.74.13ScalarsfpLowAlarmSeverityCoderead-writecurrentDefines the severity associated to the sfpLowAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.74.14ScalarsfpLowWarningAlarmSeverityCoderead-writecurrentDefines the severity associated to the sfpLowWarningAlarm and enables/disables the trap generation on status change event.
Type Definitions
NameSyntaxStatusDescription
PhysicalQuantityINTEGER { phyQtTemperature (1), phyQtVoltage (2), phyQtTxBias (3), phyQtTxPower (4), phyQtRxPower (5) }currentMeasured physical quantity
TemperatureInteger32 (-2000..2000)currentTemperature in tenth of degrees C