SINGLE-IP-MIB
65 objects
The Single IP management MIB.
Imported Objects
| DLINK-ID-REC-MIB | dlink-common-mgmt |
| RFC1155-SMI | IpAddress |
| RFC1213-MIB | ifIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE OBJECT-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY OBJECT-TYPE |
| SNMPv2-TC | DisplayString MacAddress RowStatus |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.171.12.8 | IdentityswSingleIPMIB | The Single IP management MIB. | ||
| 1.3.6.1.4.1.171.12.8.1 | NodeswSingleIPMgmt | |||
| 1.3.6.1.4.1.171.12.8.1.1 | NodeswSingleIPInfo | |||
| 1.3.6.1.4.1.171.12.8.1.1.1 | ScalarswSingleIPVersion | read-only | current | This object indicates the version of single IP management supported in the system. |
| 1.3.6.1.4.1.171.12.8.1.1.2 | ScalarswSingleIPCapability | read-only | current | This object indicates the capability of the switch system. |
| 1.3.6.1.4.1.171.12.8.1.1.3 | ScalarswSingleIPPlatform | read-only | current | This object indicates the platform of the switch system. |
| 1.3.6.1.4.1.171.12.8.1.2 | NodeswSingleIPCtrl | |||
| 1.3.6.1.4.1.171.12.8.1.2.1 | ScalarswSingleIPAdmin | read-write | current | This object indicates Single IP management is enabled or disabled on the system. |
| 1.3.6.1.4.1.171.12.8.1.2.2 | ScalarswSingleIPRoleState | read-write | current | This object indicates the role state of the switch system. |
| 1.3.6.1.4.1.171.12.8.1.2.3 | ScalarswSingleIPHoldtime | read-write | current | This object indicate the holdtime of the switch in second . default value is 180 , maximum value is 255 , minimum value is 100. |
| 1.3.6.1.4.1.171.12.8.1.2.4 | ScalarswSingleIPTimeInterval | read-write | current | This object indicate the time interval of the switch in second to periodical send out Single IP protocol control packet. default value is 60 , maximum value is… |
| 1.3.6.1.4.1.171.12.8.1.3 | TableswSingleIPMSTable | not-accessible | current | This table contain information of member switchs which belong to the single IP management group . A member will be joined into the group by row creation . Befo… |
| 1.3.6.1.4.1.171.12.8.1.3.1 | RowswSingleIPMSEntry | not-accessible | current | A list of information about member switchs belongs to the single IP management group. |
| 1.3.6.1.4.1.171.12.8.1.3.1.1 | ColumnswSingleIPMSID | read-only | current | The ID of the member switch . |
| 1.3.6.1.4.1.171.12.8.1.3.1.2 | ColumnswSingleIPMSDeviceName | read-only | current | Specifies that the name of switch . |
| 1.3.6.1.4.1.171.12.8.1.3.1.3 | ColumnswSingleIPMSMacAddr | read-only | current | This object Specifies the MAC address of the member switch. |
| 1.3.6.1.4.1.171.12.8.1.3.1.4 | ColumnswSingleIPMSFirmwareVer | read-only | current | Specifies the firmware version of the switch . |
| 1.3.6.1.4.1.171.12.8.1.3.1.5 | ColumnswSingleIPMSCapability | read-only | current | Specifies the Capability of the switch . |
| 1.3.6.1.4.1.171.12.8.1.3.1.6 | ColumnswSingleIPMSPlatform | read-only | current | Specifies the platform of the switch . |
| 1.3.6.1.4.1.171.12.8.1.3.1.7 | ColumnswSingleIPMSHoldtime | read-only | current | Specifies the holdtime of Single IP management ptotocol send by this member switch . |
| 1.3.6.1.4.1.171.12.8.1.3.1.8 | ColumnswSingleIPMSCasSource | read-create | current | Specifies the CaS id when create MS entry. The object is used only when create swSingleIPMSEntry. The value always shows 0. |
| 1.3.6.1.4.1.171.12.8.1.3.1.9 | ColumnswSingleIPMSPassword | read-create | current | Specifies the Cas password when create MS entry. The object is used only when create swSingleIPMSEntry. The value always shows zero length string. |
| 1.3.6.1.4.1.171.12.8.1.3.1.10 | ColumnswSingleIPMSRowStatus | read-create | current | This object indicates the status of this entry. Create means set CaS to MS, and DESTROY means set MS to CaS |
| 1.3.6.1.4.1.171.12.8.1.4 | TableswSingleIPCaSTable | not-accessible | current | This table contain information of candidate switchs. This table is a read only table list ,all information about candidate switchs will maintain automatically … |
| 1.3.6.1.4.1.171.12.8.1.4.1 | RowswSingleIPCaSEntry | not-accessible | current | A list of information about candidate switchs belongs to the single IP management group. |
| 1.3.6.1.4.1.171.12.8.1.4.1.1 | ColumnswSingleIPCaSID | read-only | current | The ID of the candidate switchs in the LAN learned by the command switch . |
| 1.3.6.1.4.1.171.12.8.1.4.1.2 | ColumnswSingleIPCaSDeviceName | read-only | current | Specifies that the name of switch . |
| 1.3.6.1.4.1.171.12.8.1.4.1.3 | ColumnswSingleIPCaSMacAddr | read-only | current | This object Specifies the MAC address of the candidate switch. |
| 1.3.6.1.4.1.171.12.8.1.4.1.4 | ColumnswSingleIPCaSFirmwareVer | read-only | current | Specifies the firmware version of the switch . |
| 1.3.6.1.4.1.171.12.8.1.4.1.5 | ColumnswSingleIPCaSCapability | read-only | current | Specifies the Capability of the switch . |
| 1.3.6.1.4.1.171.12.8.1.4.1.6 | ColumnswSingleIPCaSPlatform | read-only | current | Specifies the platform of the switch . |
| 1.3.6.1.4.1.171.12.8.1.4.1.7 | ColumnswSingleIPCaSHoldtime | read-only | current | Specifies the holdtime of Single IP management ptotocol send by this candidate switch . |
| 1.3.6.1.4.1.171.12.8.1.5 | TableswSingleIPGroupTable | not-accessible | current | This table contain information of Single IP manaement groups learned by the Command switch . This table is a read only table list ,all information about Single… |
| 1.3.6.1.4.1.171.12.8.1.5.1 | RowswSingleIPGroupEntry | not-accessible | current | A list of information about single IP management groups. |
| 1.3.6.1.4.1.171.12.8.1.5.1.1 | ColumnswSingleIPGroupMacAddr | read-only | current | This object Specifies the MAC address of the command switch. |
| 1.3.6.1.4.1.171.12.8.1.5.1.2 | ColumnswSingleIPGroupName | read-only | current | Specifies that the name of the Single IP management group . |
| 1.3.6.1.4.1.171.12.8.1.5.1.3 | ColumnswSingleIPGroupDeviceName | read-only | current | Specifies that the name of command switch of the group . |
| 1.3.6.1.4.1.171.12.8.1.5.1.4 | ColumnswSingleIPGroupMSNumber | read-only | current | Specifies the member switch number of the group . |
| 1.3.6.1.4.1.171.12.8.1.5.1.5 | ColumnswSingleIPGroupFirmwareVer | read-only | current | Specifies the firmware version of the switch . |
| 1.3.6.1.4.1.171.12.8.1.5.1.6 | ColumnswSingleIPGroupCapability | read-only | current | Specifies the Capability of the switch . |
| 1.3.6.1.4.1.171.12.8.1.5.1.7 | ColumnswSingleIPGroupPlatform | read-only | current | Specifies the platform of the switch . |
| 1.3.6.1.4.1.171.12.8.1.5.1.8 | ColumnswSingleIPGroupHoldtime | read-only | current | Specifies the holdtime of Single IP management ptotocol send by this command switch . |
| 1.3.6.1.4.1.171.12.8.1.6 | TableswSingleIPNeighborTable | not-accessible | current | This table contain information of Single IP manaement Neighbors learned by the switch . This table is a read only table list ,all information about Single IP N… |
| 1.3.6.1.4.1.171.12.8.1.6.1 | RowswSingleIPNeighborEntry | not-accessible | current | A list of information about single IP management Neighbors. |
| 1.3.6.1.4.1.171.12.8.1.6.1.1 | ColumnswSingleIPNBReceivedPort | read-only | current | Specifies the received port of the Neighbor switch. |
| 1.3.6.1.4.1.171.12.8.1.6.1.2 | ColumnswSingleIPNBMacAddr | read-only | current | This object Specifies the MAC address of the Neighbor switch. |
| 1.3.6.1.4.1.171.12.8.1.6.1.3 | ColumnswSingleIPNBRoleState | read-only | current | This object Specifies the role state of the Neighbor switch. |
| 1.3.6.1.4.1.171.12.8.6 | NodesingleIPMSNotify | |||
| 1.3.6.1.4.1.171.12.8.6.0 | NodesingleIPMSNotifyPrefix | |||
| 1.3.6.1.4.1.171.12.8.6.0.11 | NotificationswSingleIPMSColdStart | current | Commander switch will send swSingleIPMSColdStart notification to indicated host when its Member generate cold start notification. | |
| 1.3.6.1.4.1.171.12.8.6.0.12 | NotificationswSingleIPMSWarmStart | current | Commander switch will send swSingleIPMSWarmStart notification to indicated host when its Member generate warm start notification. | |
| 1.3.6.1.4.1.171.12.8.6.0.13 | NotificationswSingleIPMSLinkDown | current | Commander switch will send swSingleIPMSLinkDown notification to indicated host when its Member generate link down notification. | |
| 1.3.6.1.4.1.171.12.8.6.0.14 | NotificationswSingleIPMSLinkUp | current | If Commander switch will send swSingleIPMSLinkUp notification to indicated host when its Member generate link up notification. | |
| 1.3.6.1.4.1.171.12.8.6.0.15 | NotificationswSingleIPMSAuthFail | current | Commander switch will send swSingleIPMSAuthFail notification to indicated host when it Member generate authentation failure notification. | |
| 1.3.6.1.4.1.171.12.8.6.0.16 | NotificationswSingleIPMSnewRoot | current | Commander switch will send swSingleIPMSnewRoot notification to indicated host when it Member generate new root notification. | |
| 1.3.6.1.4.1.171.12.8.6.0.17 | NotificationswSingleIPMSTopologyChange | current | Commander switch will send swSingleIPMSTopologyChange notification to indicated host when it Member generate topology chnage notification. | |
| 1.3.6.1.4.1.171.12.8.6.0.18 | NotificationswSingleIPMSrisingAlarm | current | Commander switch will send swSingleIPMSrisingAlarm notification to indicated host when it Member generate rising Alarm notification. | |
| 1.3.6.1.4.1.171.12.8.6.0.19 | NotificationswSingleIPMSfallingAlarm | current | Commander switch will send swSingleIPMSfallingAlarm notification to indicated host when it Member generate falling Alarm notification. | |
| 1.3.6.1.4.1.171.12.8.6.0.20 | NotificationswSingleIPMSmacNotification | current | Commander switch will send swSingleIPMSmacNotification notification to indicated host when it Member generate mac addresses variation notification. | |
| 1.3.6.1.4.1.171.12.8.6.0.21 | NotificationswSingleIPMSPortTypeChange | current | Commander switch will send swSingleIPMSPortTypeChange notification to indicated host when it Member generate port type change notification. | |
| 1.3.6.1.4.1.171.12.8.6.0.22 | NotificationswSingleIPMSPowerStatusChg | current | Commander switch will send swSingleIPMSPowerStatusChg notification to indicated host when it Member generate Power Status change notification. | |
| 1.3.6.1.4.1.171.12.8.6.0.23 | NotificationswSingleIPMSPowerFailure | current | Commander switch will send swSingleIPMSPowerFailure notification to indicated host when it Member generate Power Failure notification. | |
| 1.3.6.1.4.1.171.12.8.6.0.24 | NotificationswSingleIPMSPowerRecover | current | Commander switch will send swSingleIPMSPowerRecover notification to indicated host when it Member generate Power Recover notification. | |
| 1.3.6.1.4.1.171.12.8.6.1 | NodesingleIPNotifyBidings | |||
| 1.3.6.1.4.1.171.12.8.6.1.1 | ScalarswSingleIPMSTrapMessage | read-only | current | The string that member switch sent. |