1.3.6.1.4.1.26854Nodeatsa
1.3.6.1.4.1.26854.1NodeatsaCorporate
1.3.6.1.4.1.26854.1.1IdentitysiteMonitoringMIBAlpha Innovations SNMP corporate naming convention Organises the SNMP OIDs according to the design centres that generate the different MIBs
1.3.6.1.4.1.26854.2NodeatsaUs
1.3.6.1.4.1.26854.3NodeatsaEu
1.3.6.1.4.1.26854.3.1NodeatsaEuDevices
1.3.6.1.4.1.26854.3.2NodesiteMonitoring
1.3.6.1.4.1.26854.3.2.1NodesiteV1
1.3.6.1.4.1.26854.3.2.1.1ScalarsiteV1GlobalStatusread-onlycurrentA textual string (alarms, normal or unknown) containing the status of the Site
1.3.6.1.4.1.26854.3.2.1.2ScalarsiteV1GlobalAlarmSeverityTyperead-onlycurrentThe alarm severity type (critical, major, minor, warning, none, disabled) of the Site
1.3.6.1.4.1.26854.3.2.1.3ScalarsiteV1GlobalAlarmSeverityLevelread-onlycurrentThe alarm severity level (0-9) of the Site
1.3.6.1.4.1.26854.3.2.1.4ScalarsiteV1GlobalAlarmSeverityTypeIntread-onlycurrentThe alarm severity type as integer (critical=4, major=3, minor=2, warning=1, none=0) of the Site
1.3.6.1.4.1.26854.3.2.1.10NodesiteV1Description
1.3.6.1.4.1.26854.3.2.1.10.1ScalarsiteV1DescriptionNumberread-onlycurrentThe number of entries in the Site Description table
1.3.6.1.4.1.26854.3.2.1.10.2TablesiteV1DescriptionTablenot-accessiblecurrentThe Description table of the Site
1.3.6.1.4.1.26854.3.2.1.10.2.1RowsiteV1DescriptionEntrynot-accessiblecurrentA Description entry
1.3.6.1.4.1.26854.3.2.1.10.2.1.1ColumnsiteV1DescriptionIndexnot-accessiblecurrentDescription Index
1.3.6.1.4.1.26854.3.2.1.10.2.1.2ColumnsiteV1DescriptionNameread-onlycurrentDescription Name
1.3.6.1.4.1.26854.3.2.1.10.2.1.3ColumnsiteV1DescriptionValueread-createcurrentDescription Value
1.3.6.1.4.1.26854.3.2.1.10.2.1.4ColumnsiteV1DescriptionEntryStatusread-createcurrentThe status of this table entry
1.3.6.1.4.1.26854.3.2.1.10.3NodesiteV1DescriptionList
1.3.6.1.4.1.26854.3.2.1.10.3.1ScalarsiteV1DescDescriptionSiteNumberread-writecurrentThe identification number of the site
1.3.6.1.4.1.26854.3.2.1.10.3.2ScalarsiteV1DescDescriptionSiteNameread-writecurrentThe name of the site
1.3.6.1.4.1.26854.3.2.1.10.3.3ScalarsiteV1DescDescriptionShortDescriptionread-writecurrentA short description of the site
1.3.6.1.4.1.26854.3.2.1.10.3.4ScalarsiteV1DescDescriptionInforead-writecurrentSome more information about the site
1.3.6.1.4.1.26854.3.2.1.10.3.5ScalarsiteV1DescDescriptionDescriptionread-writecurrentA free text zone to write a system description
1.3.6.1.4.1.26854.3.2.1.10.3.6ScalarsiteV1DescDescriptionReferenceread-writecurrentA free text zone to write the customer reference of the system
1.3.6.1.4.1.26854.3.2.1.10.3.7ScalarsiteV1DescDescriptionContactNameread-writecurrentContact Name
1.3.6.1.4.1.26854.3.2.1.10.3.8ScalarsiteV1DescDescriptionPhoneNumberread-writecurrentPhone Number
1.3.6.1.4.1.26854.3.2.1.10.3.11ScalarsiteV1DescDescriptionStreetread-writecurrentStreet part of the site address
1.3.6.1.4.1.26854.3.2.1.10.3.12ScalarsiteV1DescDescriptionCityread-writecurrentCity part of the site address
1.3.6.1.4.1.26854.3.2.1.10.3.13ScalarsiteV1DescDescriptionProvinceread-writecurrentProvince part of the site address
1.3.6.1.4.1.26854.3.2.1.10.3.14ScalarsiteV1DescDescriptionPostalCoderead-writecurrentPostal Code part of the site address
1.3.6.1.4.1.26854.3.2.1.10.3.15ScalarsiteV1DescDescriptionRegionread-writecurrentRegion part of the site address
1.3.6.1.4.1.26854.3.2.1.10.3.16ScalarsiteV1DescDescriptionCountryread-writecurrentCountry part of the site address
1.3.6.1.4.1.26854.3.2.1.10.3.21ScalarsiteV1DescDescriptionGroup1read-writecurrentGroup Level 1 (For Armada Clustering)
1.3.6.1.4.1.26854.3.2.1.10.3.22ScalarsiteV1DescDescriptionGroup2read-writecurrentGroup Level 2 (For Armada Clustering)
1.3.6.1.4.1.26854.3.2.1.10.3.23ScalarsiteV1DescDescriptionGroup3read-writecurrentGroup Level 3 (For Armada Clustering)
1.3.6.1.4.1.26854.3.2.1.10.3.24ScalarsiteV1DescDescriptionGroup4read-writecurrentGroup Level 4 (For Armada Clustering)
1.3.6.1.4.1.26854.3.2.1.10.3.25ScalarsiteV1DescDescriptionGroup5read-writecurrentGroup Level 5 (For Armada Clustering)
1.3.6.1.4.1.26854.3.2.1.10.3.31ScalarsiteV1DescDescriptionLatituderead-writecurrentThe latitude of the site
1.3.6.1.4.1.26854.3.2.1.10.3.32ScalarsiteV1DescDescriptionLongituderead-writecurrentThe longitude of the site
1.3.6.1.4.1.26854.3.2.1.10.3.33ScalarsiteV1DescDescriptionAltituderead-writecurrentThe altitude of the site
1.3.6.1.4.1.26854.3.2.1.10.3.91ScalarsiteV1DescControllerSoftwareRevisionread-onlycurrentThe software revision of Comp@s (read only)
1.3.6.1.4.1.26854.3.2.1.10.3.92ScalarsiteV1DescControllerOperatingSystemRevisionread-onlycurrentThe operating system of Comp@s (read only)
1.3.6.1.4.1.26854.3.2.1.10.3.93ScalarsiteV1DescControllerCPUread-onlycurrentInformation about the CPU
1.3.6.1.4.1.26854.3.2.1.10.3.94ScalarsiteV1DescControllerCardread-onlycurrentInformation about the hardware system containing Compas
1.3.6.1.4.1.26854.3.2.1.10.3.100ScalarsiteV1DescControllerStarterVersionread-onlycurrentInformation about the starter component of Compas
1.3.6.1.4.1.26854.3.2.1.10.3.105ScalarsiteV1DescControllerFactoryCompasVersionread-onlycurrentInformation about the revision of Compas in Factory folder
1.3.6.1.4.1.26854.3.2.1.10.3.106ScalarsiteV1DescControllerUserCompasVersionread-onlycurrentInformation about the revision of Compas in user folder
1.3.6.1.4.1.26854.3.2.1.10.3.110ScalarsiteV1DescControllerFactoryFTPServerVersionread-onlycurrentInformation about the revision of Ftp Server in Factory folder
1.3.6.1.4.1.26854.3.2.1.10.3.111ScalarsiteV1DescControllerUserFTPServerVersionread-onlycurrentInformation about the revision of Ftp Server in Factory folder
1.3.6.1.4.1.26854.3.2.1.11NodesiteV1Alarm
1.3.6.1.4.1.26854.3.2.1.11.1ScalarsiteV1AlarmNumberread-onlycurrentThe number of entries in the Site Alarm table
1.3.6.1.4.1.26854.3.2.1.11.2TablesiteV1AlarmTablenot-accessiblecurrentThe table of Alarm entries
1.3.6.1.4.1.26854.3.2.1.11.2.1RowsiteV1AlarmEntrynot-accessiblecurrentAn alarm entry
1.3.6.1.4.1.26854.3.2.1.11.2.1.1ColumnsiteV1AlarmIndexnot-accessiblecurrentAlarm Index
1.3.6.1.4.1.26854.3.2.1.11.2.1.2ColumnsiteV1AlarmNameread-onlycurrentAlarm Name
1.3.6.1.4.1.26854.3.2.1.11.2.1.3ColumnsiteV1AlarmActiveread-onlycurrentIs the Alarm active ? 'true' for active, 'false' for not-active
1.3.6.1.4.1.26854.3.2.1.11.2.1.4ColumnsiteV1AlarmSeverityTyperead-writecurrentThe alarm severity type (major, minor, warning, none, disabled) of this alarm entry
1.3.6.1.4.1.26854.3.2.1.11.2.1.5ColumnsiteV1AlarmSeverityLevelread-writecurrentThe alarm severity level (0-9) of this alarm entry
1.3.6.1.4.1.26854.3.2.1.11.2.1.6ColumnsiteV1AlarmStartTimeread-onlycurrentThe last start time of this alarm entry (null if never active)
1.3.6.1.4.1.26854.3.2.1.11.2.1.7ColumnsiteV1AlarmStopTimeread-onlycurrentThe last stop time of this alarm entry (null if alarm active)
1.3.6.1.4.1.26854.3.2.1.11.2.1.8ColumnsiteV1AlarmEntryStatusread-createcurrentThe status of this table entry - not used, only for MIB compliance
1.3.6.1.4.1.26854.3.2.1.11.3ScalarsiteV1AlarmSummaryread-onlycurrentSummary bit vector with all the alarms state of the Site. A '1' means alarm active, '0' means not active. Unimplemented alarms are always '0'.
1.3.6.1.4.1.26854.3.2.1.12NodesiteV1Event
1.3.6.1.4.1.26854.3.2.1.12.1ScalarsiteV1EventNumberread-onlycurrentThe number of entries in the Event Table related to the Site
1.3.6.1.4.1.26854.3.2.1.12.2TablesiteV1EventTablenot-accessiblecurrentThe Event table related to the Site
1.3.6.1.4.1.26854.3.2.1.12.2.1RowsiteV1EventEntrynot-accessiblecurrent.
1.3.6.1.4.1.26854.3.2.1.12.2.1.1ColumnsiteV1EventIndexnot-accessiblecurrentEvent Index
1.3.6.1.4.1.26854.3.2.1.12.2.1.2ColumnsiteV1EventIdread-onlycurrentEvent Index
1.3.6.1.4.1.26854.3.2.1.12.2.1.3ColumnsiteV1EventNameread-onlycurrentEvent Name
1.3.6.1.4.1.26854.3.2.1.12.2.1.4ColumnsiteV1EventDateTimeread-onlycurrentThe date and time of the event
1.3.6.1.4.1.26854.3.2.1.12.2.1.5ColumnsiteV1EventSeverityTyperead-onlycurrentThe event severity type ('major', 'minor', 'warning' or 'none')
1.3.6.1.4.1.26854.3.2.1.12.2.1.6ColumnsiteV1EventSeverityLevelread-onlycurrentThe event severity level (0-9)
1.3.6.1.4.1.26854.3.2.1.12.2.1.7ColumnsiteV1EventEntryStatusread-createcurrentThe status of this table entry
1.3.6.1.4.1.26854.3.2.1.13NodesiteV1Data
1.3.6.1.4.1.26854.3.2.1.13.1ScalarsiteV1DataNumberread-onlycurrentThe number of entries in the Data Table related to the Site
1.3.6.1.4.1.26854.3.2.1.13.2TablesiteV1DataTablenot-accessiblecurrentThe table of Data entries
1.3.6.1.4.1.26854.3.2.1.13.2.1RowsiteV1DataEntrynot-accessiblecurrentA data entry
1.3.6.1.4.1.26854.3.2.1.13.2.1.1ColumnsiteV1DataIndexnot-accessiblecurrentThe data index
1.3.6.1.4.1.26854.3.2.1.13.2.1.2ColumnsiteV1DataNameread-onlycurrentThe data name
1.3.6.1.4.1.26854.3.2.1.13.2.1.3ColumnsiteV1DataValueread-onlycurrentThe data value
1.3.6.1.4.1.26854.3.2.1.13.2.1.4ColumnsiteV1DataEntryStatusread-createcurrentThe status of this table entry - not used, only present for compliance
1.3.6.1.4.1.26854.3.2.1.13.3NodesiteV1DataList
1.3.6.1.4.1.26854.3.2.1.13.3.1ScalarsiteV1DataNetworkCurrentIPAddressread-onlycurrentThis is the actual IP address of the Comp@s platform. If the Ethernet cable is not correctly connected, the address will be 0.0.0.0.
1.3.6.1.4.1.26854.3.2.1.13.3.2ScalarsiteV1DataNetworkCurrentIPMaskread-onlycurrentThis is the actual IP address of the Comp@s platform. If the Ethernet cable is not correctly connected, the address will be 0.0.0.0.
1.3.6.1.4.1.26854.3.2.1.13.3.3ScalarsiteV1DataNetworkCurrentMACAddressread-onlycurrentThis is the MAC address of IP interface.
1.3.6.1.4.1.26854.3.2.1.13.3.11ScalarsiteV1DataControllerLicensedOptionsread-onlycurrentThis is the options of the actual license.
1.3.6.1.4.1.26854.3.2.1.13.3.21ScalarsiteV1DataTimeDateAndTimeLocalread-onlycurrentThis is the local time of the monitoring.
1.3.6.1.4.1.26854.3.2.1.13.3.22ScalarsiteV1DataTimeDateAndTimeUTCread-onlycurrentThis is the UTC time of the monitoring.
1.3.6.1.4.1.26854.3.2.1.13.3.31ScalarsiteV1DataControllerMonitoringMemoryUsedread-onlycurrentThis is actual amount of RAM memory used by the application.
1.3.6.1.4.1.26854.3.2.1.13.3.32ScalarsiteV1DataControllerCPUPercentageUsageread-onlycurrentThis is actual percentage of CPU used
1.3.6.1.4.1.26854.3.2.1.13.3.33ScalarsiteV1DataControllerFreeFlashMemorySpaceread-onlycurrentThis is free flash memory available on the Comp@s card, in Megabytes
1.3.6.1.4.1.26854.3.2.1.13.3.35ScalarsiteV1DataControllerFTPServerStatusread-onlycurrentStatus of the FTP Server. Compatible only with version >= 2.26.X.X. The configuration is available at controller -> FTP Server page.
1.3.6.1.4.1.26854.3.2.1.13.3.41ScalarsiteV1DataDataRecordsTotalFifoSizeOfSecondRecordsread-onlycurrentNA
1.3.6.1.4.1.26854.3.2.1.13.3.42ScalarsiteV1DataDataRecordsTotalFifoSizeOfMinuteRecordsread-onlycurrentNA
1.3.6.1.4.1.26854.3.2.1.13.3.43ScalarsiteV1DataDataRecordsTotalFifoSizeOfHourRecordsread-onlycurrentNA
1.3.6.1.4.1.26854.3.2.1.13.3.44ScalarsiteV1DataDataRecordsTotalFifoSizeOfDayRecordsread-onlycurrentNA
1.3.6.1.4.1.26854.3.2.1.13.3.51ScalarsiteV1DataInventoryCANBusNodeIDsread-onlycurrentThe coma separated list of the node ids present on the CAN bus.
1.3.6.1.4.1.26854.3.2.1.13.3.166ScalarsiteV1DataCloudLinkCloudLinkStateread-onlycurrentCloud Link State
1.3.6.1.4.1.26854.3.2.1.15NodesiteV1Config
1.3.6.1.4.1.26854.3.2.1.15.1ScalarsiteV1ConfigNumberread-onlycurrentThe number of entries in the Config table related to the Site
1.3.6.1.4.1.26854.3.2.1.15.2TablesiteV1ConfigTablenot-accessiblecurrentThe table of Config entries related to the Site
1.3.6.1.4.1.26854.3.2.1.15.2.1RowsiteV1ConfigEntrynot-accessiblecurrentA Config entry
1.3.6.1.4.1.26854.3.2.1.15.2.1.1ColumnsiteV1ConfigIndexnot-accessiblecurrentThe Config entry Index
1.3.6.1.4.1.26854.3.2.1.15.2.1.2ColumnsiteV1ConfigNameread-onlycurrentThe Config entry name
1.3.6.1.4.1.26854.3.2.1.15.2.1.3ColumnsiteV1ConfigValueread-writecurrentThe Config entry value
1.3.6.1.4.1.26854.3.2.1.15.2.1.4ColumnsiteV1ConfigEntryStatusread-createcurrentThe status of this table entry - not used, only for compliance
1.3.6.1.4.1.26854.3.2.1.15.3NodesiteV1ConfigList
1.3.6.1.4.1.26854.3.2.1.15.3.1ScalarsiteV1CfgNetworkDHCPEnabledread-writecurrentThe monitoring will try to get an IP with the DHCP protocol if this parameter is set to True. By default, this parameter is set to False.
1.3.6.1.4.1.26854.3.2.1.15.3.2ScalarsiteV1CfgNetworkIPAddressIfStaticread-writecurrentThe static IP address of the monitoring. This configuration parameter is not used if the DHCP is enabled. The default IP is 192.168.45.2.
1.3.6.1.4.1.26854.3.2.1.15.3.3ScalarsiteV1CfgNetworkSubnetMaskIfStaticread-writecurrentThe static Subnet Mask of the monitoring. This configuration parameter is not used if the DHCP is enabled. The default mask is 255.255.255.0.
1.3.6.1.4.1.26854.3.2.1.15.3.4ScalarsiteV1CfgNetworkDefaultGatewayIfStaticread-writecurrentThe static Default Gateway of the monitoring. This configuration parameter is not used if DHCP is enabled. This is only useful if the monitoring have to use a …
1.3.6.1.4.1.26854.3.2.1.15.3.5ScalarsiteV1CfgNetworkDNSIfStaticread-writecurrentThe static DNS of the monitoring. This configuration parameter is used to resolve URI and server name. This is not necessary if you are only IP address as targ…
1.3.6.1.4.1.26854.3.2.1.15.3.8ScalarsiteV1CfgNetworkMaxTransmissionUnitread-writecurrentSpecifies the TCP/IP MTU for the network interface
1.3.6.1.4.1.26854.3.2.1.15.3.11ScalarsiteV1CfgTimeSNTPTimeServerread-writecurrentThe address of the server acting as SNTP timer server. If this server is not valid, the monitoring cannot update automatically his time. You can use several ti…
1.3.6.1.4.1.26854.3.2.1.15.3.14ScalarsiteV1CfgTimeTimeZoneNameread-writecurrentThe Time Zone of the site
1.3.6.1.4.1.26854.3.2.1.15.3.15ScalarsiteV1CfgTimeSNTPTimeRefreshread-writecurrentSet the time between synchronisation with the SNTP server (max 1000 hours, by default 178)
1.3.6.1.4.1.26854.3.2.1.15.3.16ScalarsiteV1CfgTimeSNTPTimeRecoveryRefreshread-writecurrentSet the time to wait before retry if a synchronisation fail (max 1000 hours, by default 24)
1.3.6.1.4.1.26854.3.2.1.15.3.22ScalarsiteV1CfgWebServerWebServerSecurityEnabledread-writecurrentThis is a True/False parameter used to activate or deactivate the access control to the web server.
1.3.6.1.4.1.26854.3.2.1.15.3.23ScalarsiteV1CfgWebServerWebServerPortread-writecurrentThis is an unsigned integer parameter used to configure the port at which the web server is accessible. By default, the port is 80. If you change this port, yo…
1.3.6.1.4.1.26854.3.2.1.15.3.24ScalarsiteV1CfgWebServerWebAuthenticationMethodread-writecurrentThe web access security can be managed with 3 authentication methods: Basic Access, Digest Access or Basic with Radius.
1.3.6.1.4.1.26854.3.2.1.15.3.26ScalarsiteV1CfgWebServerHttpsWebServerPortread-writecurrentThis is a port number to activate or deactivate the https web server - 0 or 443 by default
1.3.6.1.4.1.26854.3.2.1.15.3.31ScalarsiteV1CfgWebServerDefaultPageread-writecurrentThe default page displayed on logon (dashboard, site, summary, alarm_event, ...)
1.3.6.1.4.1.26854.3.2.1.15.3.41ScalarsiteV1CfgXMLXMLEventPostingActivatedread-writecurrentThis is a True/False parameter used to activate or deactivate the XML event posting.
1.3.6.1.4.1.26854.3.2.1.15.3.42ScalarsiteV1CfgXMLXMLEventPostingRefreshTimeread-writecurrentThe minimal time in second between to calculation of the XML events to send. By default, this is done every two seconds.
1.3.6.1.4.1.26854.3.2.1.15.3.43ScalarsiteV1CfgXMLXMLEventPostingTimeoutread-writecurrentThe timeout in millisecond when trying to post XML data to a Web Server.
1.3.6.1.4.1.26854.3.2.1.15.3.45ScalarsiteV1CfgXMLXMLEventPostingToSecOnlyIfPrimFailread-writecurrentIf this parameter is set to true, the events will be sent to secondary only if primary server is not available. If this parameter is set to false, all the even…
1.3.6.1.4.1.26854.3.2.1.15.3.46ScalarsiteV1CfgXMLXMLTablesToPostOnXMLEventread-writecurrentThe list of the tables to send when an event is generated. (description,alarm,data,config,control). This allows to have armada database updated on event.
1.3.6.1.4.1.26854.3.2.1.15.3.51ScalarsiteV1CfgXMLXMLHeartbeatTimeread-writecurrentThis is the time between 2 XML Post of heartbeat. If set to 0, no heartbeat.
1.3.6.1.4.1.26854.3.2.1.15.3.61ScalarsiteV1CfgSNMPSNMPActivatedread-writecurrentThis is a True/False parameter used to activate or deactivate the SNMP agent.
1.3.6.1.4.1.26854.3.2.1.15.3.63ScalarsiteV1CfgSNMPSNMPTrapVersionread-writecurrentTraps/Notification can be sent with SNMP V1, V2c or V3 format.
1.3.6.1.4.1.26854.3.2.1.15.3.64ScalarsiteV1CfgSNMPSNMPGETMinSecurityLevelread-writecurrent4 choices are available: No Authentication, V1 Community, V2c Community or V3.
1.3.6.1.4.1.26854.3.2.1.15.3.65ScalarsiteV1CfgSNMPSNMPSETMinSecurityLevelread-writecurrent4 choices are available: No Authentication, V1 Community, V2c Community or V3.
1.3.6.1.4.1.26854.3.2.1.15.3.66ScalarsiteV1CfgSNMPSNMPV3AuthAlgorithmread-writecurrent3 choices are available: MD5, SHA, Any
1.3.6.1.4.1.26854.3.2.1.15.3.67ScalarsiteV1CfgSNMPSNMPV3PrivacyAlgorithmread-writecurrent3 choices are available: DES, AES, 3DES
1.3.6.1.4.1.26854.3.2.1.15.3.68ScalarsiteV1CfgSNMPSNMPV3PrivacyPasswordread-writecurrentThe global SNMP V3 Encryption Password. This one is common for all the users to avoid complexity
1.3.6.1.4.1.26854.3.2.1.15.3.69ScalarsiteV1CfgSNMPSNMPV3EngineIDread-writecurrentThe SNMP V3 Local Engine ID string
1.3.6.1.4.1.26854.3.2.1.15.3.72ScalarsiteV1CfgSNMPSNMPV3TrapAuthAlgorithmread-writecurrent2 choices are available: MD5, SHA
1.3.6.1.4.1.26854.3.2.1.15.3.73ScalarsiteV1CfgSNMPSNMPV3TrapPrivacyAlgorithmread-writecurrent3 choices are available: DES, AES, 3DES
1.3.6.1.4.1.26854.3.2.1.15.3.74ScalarsiteV1CfgSNMPSNMPV3TrapUsernameread-writecurrentThe SNMP V3 Trap UserName used for all the SNMP V3 traps
1.3.6.1.4.1.26854.3.2.1.15.3.75ScalarsiteV1CfgSNMPSNMPV3TrapAuthPasswordread-writecurrentThe SNMP V3 Trap Authentication Password
1.3.6.1.4.1.26854.3.2.1.15.3.76ScalarsiteV1CfgSNMPSNMPV3TrapPrivacyPasswordread-writecurrentThe SNMP V3 Trap Privacy Password
1.3.6.1.4.1.26854.3.2.1.15.3.77ScalarsiteV1CfgSNMPSiteDescriptionIdsIncludedInTrapsread-writecurrentList of site Description Elements to send on traps. (to have the site reference and the city in each trap for example). The list is separated with ';'
1.3.6.1.4.1.26854.3.2.1.15.3.81ScalarsiteV1CfgGenericGenerateEventOnConfChangesread-writecurrentThis is a True/False parameter used to activate or deactivate the tracking of configuration changes
1.3.6.1.4.1.26854.3.2.1.15.3.82ScalarsiteV1CfgDataRecordsAutoArchivePeriodDataRecordread-writecurrentPeriod in hour to auto save records (when detailled and long duration records are needed). 0 means disabled.
1.3.6.1.4.1.26854.3.2.1.15.3.83ScalarsiteV1CfgGenericGenerateEventOnControlExecutionread-writecurrentThis is a True/False parameter used to activate or deactivate the tracking of control execution
1.3.6.1.4.1.26854.3.2.1.15.3.84ScalarsiteV1CfgGenericGenerateEventOnAlarmAcknowledgeread-writecurrentThis is a True/False parameter used to activate or deactivate the tracking of alarm acknowledgment
1.3.6.1.4.1.26854.3.2.1.15.3.91ScalarsiteV1CfgInventoryRequiredCANBusNodeIDsread-writecurrentThis is a coma separated list with the required CAN bus node ids
1.3.6.1.4.1.26854.3.2.1.15.3.92ScalarsiteV1CfgInventoryLSSCANidrangeread-writecurrentBy default 50-80, means up to 50 Can Nodes like rectifiers with CAN Id 50 to 80. To support up to 100 rectifiers, change it to 1-100.
1.3.6.1.4.1.26854.3.2.1.15.3.93ScalarsiteV1CfgInventorySystemNodesDefinitionread-writecurrentdc3(30-100)
1.3.6.1.4.1.26854.3.2.1.15.3.95ScalarsiteV1CfgInventoryLSSCANOpenSavedConfread-writecurrentNA
1.3.6.1.4.1.26854.3.2.1.15.3.101ScalarsiteV1CfgUsersAdministratorLoginPasswordread-writecurrentThis is the login and the password of the administrator. It is saved with a special syntax. First the login in clear, followed of 2 points, followed of the MD5…
1.3.6.1.4.1.26854.3.2.1.15.3.102ScalarsiteV1CfgUsersUser1LoginPasswordread-writecurrentThis is the login and the password of the user number 1.
1.3.6.1.4.1.26854.3.2.1.15.3.103ScalarsiteV1CfgUsersUser2LoginPasswordread-writecurrentThis is the login and the password of the user number 2.
1.3.6.1.4.1.26854.3.2.1.15.3.104ScalarsiteV1CfgUsersUser3LoginPasswordread-writecurrentThis is the login and the password of the user number 3.
1.3.6.1.4.1.26854.3.2.1.15.3.105ScalarsiteV1CfgUsersUser4LoginPasswordread-writecurrentThis is the login and the password of the user number 4.
1.3.6.1.4.1.26854.3.2.1.15.3.106ScalarsiteV1CfgUsersUser5LoginPasswordread-writecurrentThis is the login and the password of the user number 5.
1.3.6.1.4.1.26854.3.2.1.15.3.111ScalarsiteV1CfgRadiusAuthenticationRadiusServerread-writecurrentRadius Server address. If you have a secondary server, you could use a coma to separate it.
1.3.6.1.4.1.26854.3.2.1.15.3.112ScalarsiteV1CfgRadiusAuthenticationRadiusPortread-writecurrentRadius Port. If you have a secondary server, you could use a coma to separate it.
1.3.6.1.4.1.26854.3.2.1.15.3.113ScalarsiteV1CfgRadiusAuthenticationRadiusSecretread-writecurrentRadius PassPhrase
1.3.6.1.4.1.26854.3.2.1.15.3.120ScalarsiteV1CfgEmailEnableEmailFeatureread-writecurrentEnable/Disable the email feature
1.3.6.1.4.1.26854.3.2.1.15.3.121ScalarsiteV1CfgEmailSmtpServerread-writecurrentSmtp Server. If you are using a domain name, make sure you configured the network Dns (CF5)
1.3.6.1.4.1.26854.3.2.1.15.3.122ScalarsiteV1CfgEmailSmtpDomainread-writecurrentSmtp Domain. (Required by some servers.)
1.3.6.1.4.1.26854.3.2.1.15.3.123ScalarsiteV1CfgEmailSmtpUserLoginPasswordread-writecurrentSmtp Login and Password. The password is encrypted. To enter a new login and password, enter login:password and validate, the password will be encrypted.
1.3.6.1.4.1.26854.3.2.1.15.3.130ScalarsiteV1CfgEmailMailSenderread-writecurrentMail Sender (The 'From' of the emails you will receive)
1.3.6.1.4.1.26854.3.2.1.15.3.131ScalarsiteV1CfgEmailMailRecipientsread-writecurrentMail Recipients, separated with semicolon ';'
1.3.6.1.4.1.26854.3.2.1.15.3.135ScalarsiteV1CfgEmailMinimalSeverityTypeToSendMailread-writecurrentThis is the minimal severity of the event to send a Summary Mail
1.3.6.1.4.1.26854.3.2.1.15.3.150ScalarsiteV1CfgControllerAutomaticRebootread-writecurrentCron rules used in order to restart automatically the controller. Before rebooting configuration, events and data records are saved.
1.3.6.1.4.1.26854.3.2.1.15.3.161ScalarsiteV1CfgCloudLinkCloudEnabledread-writecurrentEnable Cloud Connection
1.3.6.1.4.1.26854.3.2.1.15.3.162ScalarsiteV1CfgCloudLinkCloudServerread-writecurrentCloud Server
1.3.6.1.4.1.26854.3.2.1.15.3.163ScalarsiteV1CfgCloudLinkCloudPortread-writecurrentCloud Port
1.3.6.1.4.1.26854.3.2.1.15.3.164ScalarsiteV1CfgCloudLinkCloudCredentialread-writecurrentEnter Credential of your AlphaCloud account in order to connect. You have to enter username:password in order to save your credential.
1.3.6.1.4.1.26854.3.2.1.15.3.165ScalarsiteV1CfgCloudLinkCloudClusterread-writecurrentCloud Cluster
1.3.6.1.4.1.26854.3.2.1.15.3.210ScalarsiteV1CfgInventoryRS485ExtensionsConfread-writecurrentThe configuration string for RS485 Extensions
1.3.6.1.4.1.26854.3.2.1.15.3.220ScalarsiteV1CfgInventoryEthernetExtensionsConfread-writecurrentThe configuration string for Ethernet Extensions
1.3.6.1.4.1.26854.3.2.1.15.3.250ScalarsiteV1CfgScriptingEnabledscriptsread-writecurrentThis parameter enable all CompasLua Scripting capabilities. You can control scripts in Files -> Files manager > scripting tab.
1.3.6.1.4.1.26854.3.2.1.15.3.251ScalarsiteV1CfgScriptingNumberofErrorsbeforetriggeringalarmread-writecurrentNumber of errors before triggering the scripting error alarm. When number of error is higher than this parameter, the alarm is triggered. If 0 is set, the alar…
1.3.6.1.4.1.26854.3.2.1.15.3.521ScalarsiteV1CfgGenericReadAccessUserNumbersread-writecurrentThe list of the user numbers which have read access to this equipment. The user numbers are coma separated. The accepted user id are 1,2,3,4 and 5. Ex: 1,3,4
1.3.6.1.4.1.26854.3.2.1.15.3.522ScalarsiteV1CfgGenericWriteAccessUserNumbersread-writecurrentThe list of the user numbers which have write access to this equipment. This means that these users can modify the configuration element, the alarm settings an…
1.3.6.1.4.1.26854.3.2.1.15.3.601ScalarsiteV1CfgGenericEventTableLengthread-writecurrentThe maximum length of the table. The value must be comprised between 10 and 4000
1.3.6.1.4.1.26854.3.2.1.15.3.611ScalarsiteV1CfgSNMPSNMPTrapTargetsIPread-writecurrentOne or multiple target IP to send traps, coma separated. Ex: 130.145.23.1, 130.23.12.45
1.3.6.1.4.1.26854.3.2.1.15.3.612ScalarsiteV1CfgSNMPMinimalEventSeverityForTrapsread-writecurrentThis is the minimal severity of the event to send a SNMP trap
1.3.6.1.4.1.26854.3.2.1.15.3.651ScalarsiteV1CfgXMLXMLEventsPrimPostURLread-writecurrentThis is the first URL at which the events related to this equipment must be posted. The XML ETSI standard is used in the posted data content.
1.3.6.1.4.1.26854.3.2.1.15.3.652ScalarsiteV1CfgXMLXMLEventsPrimPostLoginread-writecurrentThe login which must be used when posting events to the primary server
1.3.6.1.4.1.26854.3.2.1.15.3.653ScalarsiteV1CfgXMLXMLEventsPrimPostPasswordread-writecurrentThe password which must be used when posting events to the primary server
1.3.6.1.4.1.26854.3.2.1.15.3.661ScalarsiteV1CfgXMLXMLEventsSecPostURLread-writecurrentThis is the second URL at which the events related to this equipment must be posted. The XML ETSI standard is used in the posted data content. This allows havi…
1.3.6.1.4.1.26854.3.2.1.15.3.662ScalarsiteV1CfgXMLXMLEventsSecPostLoginread-writecurrentThe login which must be used when posting events to the secondary server
1.3.6.1.4.1.26854.3.2.1.15.3.663ScalarsiteV1CfgXMLXMLEventsSecPostPasswordread-writecurrentThe password which must be used when posting events to the secondary server
1.3.6.1.4.1.26854.3.2.1.15.3.901ScalarsiteV1CfgPLCNumberOfPLCDataread-writecurrentThe number of PLC data. Every equipment can manage up to 30 user programmable data. Data elements are automatically added in the data table. Configuration para…
1.3.6.1.4.1.26854.3.2.1.15.3.902ScalarsiteV1CfgPLCNumberOfPLCAlarmread-writecurrentThe number of PLC alarm. Every equipment can manage up to 30 user programmable alarms. Alarm elements are automatically added in the alarm table. The alarm par…
1.3.6.1.4.1.26854.3.2.1.16NodesiteV1Control
1.3.6.1.4.1.26854.3.2.1.16.1ScalarsiteV1ControlNumberread-onlycurrentThe number of entries in the Control table related to the Site
1.3.6.1.4.1.26854.3.2.1.16.2TablesiteV1ControlTablenot-accessiblecurrentThe table of Control entries related to the Site
1.3.6.1.4.1.26854.3.2.1.16.2.1RowsiteV1ControlEntrynot-accessiblecurrentA Control entry
1.3.6.1.4.1.26854.3.2.1.16.2.1.1ColumnsiteV1ControlIndexnot-accessiblecurrentThe Control entry Index
1.3.6.1.4.1.26854.3.2.1.16.2.1.2ColumnsiteV1ControlNameread-onlycurrentThe Control entry name
1.3.6.1.4.1.26854.3.2.1.16.2.1.3ColumnsiteV1ControlValueread-writecurrentThe Control entry value
1.3.6.1.4.1.26854.3.2.1.16.2.1.4ColumnsiteV1ControlEntryStatusread-createcurrentThe status of this table entry - not used, only for compliance
1.3.6.1.4.1.26854.3.2.1.16.3NodesiteV1ControlList
1.3.6.1.4.1.26854.3.2.1.16.3.1ScalarsiteV1CtrlControllerRebootControllerread-writecurrentWriting a '1' to this control element will reboot the monitoring. Events and Records will be saved.
1.3.6.1.4.1.26854.3.2.1.16.3.2ScalarsiteV1CtrlControllerSaveConfAndRebootControllerread-writecurrentWriting a '1' to this control element will first save the actual configuration and will reboot the monitoring after.
1.3.6.1.4.1.26854.3.2.1.16.3.3ScalarsiteV1CtrlControllerRebootControllerWithoutSavingRecordsread-writecurrentWriting a '1' to this control element will reboot the monitoring without saving records
1.3.6.1.4.1.26854.3.2.1.16.3.6ScalarsiteV1CtrlNetworkApplyNetworkConfread-writecurrentWriting a '1' to this control element will reconfigure the ethernet according to the Network Configuration. If you change the IP address in the config table wi…
1.3.6.1.4.1.26854.3.2.1.16.3.11ScalarsiteV1CtrlTimeForceSNTPTimeRefreshread-writecurrentWriting a '1' to this control element will force the monitoring to try to refresh his time with the configured SNTP Time Server.
1.3.6.1.4.1.26854.3.2.1.16.3.12ScalarsiteV1CtrlTimeSetLocalTimeread-writecurrentWriting a date and time to this control element allows to manually change the local time of the monitoring. The syntax of the date and the time is: 2007-11-19T…
1.3.6.1.4.1.26854.3.2.1.16.3.13ScalarsiteV1CtrlTimeSetUTCTimeread-writecurrentWriting a date and time to this control element allows to manually change the UTC time of the monitoring. The syntax of the date and the time is: 2007-11-19T13…
1.3.6.1.4.1.26854.3.2.1.16.3.14ScalarsiteV1CtrlTimeResetUptimeread-writecurrentWriting a '1' to this control element will reset the uptime of the monitoring.
1.3.6.1.4.1.26854.3.2.1.16.3.20ScalarsiteV1CtrlControllerCleanandSaveXMLUserConfread-writecurrentWriting a '1' to this control element will remove the configuration sections related to missing equipments, than save all the configuration of all the connecte…
1.3.6.1.4.1.26854.3.2.1.16.3.21ScalarsiteV1CtrlControllerSaveXMLUserConfread-writecurrentWriting a '1' to this control element will save all the configuration of all the connected (or previously connected) equipment in a XML format. This file is re…
1.3.6.1.4.1.26854.3.2.1.16.3.22ScalarsiteV1CtrlControllerSaveInventoryread-writecurrentWriting a '1' to this control element will save save the inventory in a XML format. This file is read when the monitoring is starting in order to configure the…
1.3.6.1.4.1.26854.3.2.1.16.3.33ScalarsiteV1CtrlDataRecordsSaveDataRecordsread-writecurrentWriting a '1' to this control element will force the monitoring to save all the data records. This is useful if you want to unpower the Comp@s monitoring. This…
1.3.6.1.4.1.26854.3.2.1.16.3.34ScalarsiteV1CtrlDataRecordsExportDataRecordsinCSVread-writecurrentWriting a '1' to this control element will force the monitoring to save all the CVS records files. The CSV files are stored in the records folder.
1.3.6.1.4.1.26854.3.2.1.16.3.35ScalarsiteV1CtrlDataRecordsArchiveDataRecordsread-writecurrentWriting a '1' to this control element will force the monitoring to save all the data records. This is useful if you want to unpower the Comp@s monitoring. This…
1.3.6.1.4.1.26854.3.2.1.16.3.36ScalarsiteV1CtrlDataRecordsDeleteAllDataRecordsread-writecurrentWriting a '1' to this control element will force the monitoring to save all the data records. This is useful if you want to unpower the Comp@s monitoring. This…
1.3.6.1.4.1.26854.3.2.1.16.3.40ScalarsiteV1CtrlControllerEmulateRecordsread-writecurrentNA
1.3.6.1.4.1.26854.3.2.1.16.3.41ScalarsiteV1CtrlControllerReloadTranslationsread-writecurrentWriting a '1' to this control element will reload all the csv translation files
1.3.6.1.4.1.26854.3.2.1.16.3.51ScalarsiteV1CtrlControllerReloadLicenseread-writecurrentWriting a '1' to this control element will reload the license file
1.3.6.1.4.1.26854.3.2.1.16.3.55ScalarsiteV1CtrlControllerManageFTPServerread-writecurrentThis Control is used to manage the FTP Server
1.3.6.1.4.1.26854.3.2.1.16.3.61ScalarsiteV1CtrlInventoryRemoveAbsentEquipmentsread-writecurrentNA
1.3.6.1.4.1.26854.3.2.1.16.3.81ScalarsiteV1CtrlInventoryResetCANBusNoderead-writecurrentWriting a valid CAN bus node id to this control element will reset the correspondent device.
1.3.6.1.4.1.26854.3.2.1.16.3.82ScalarsiteV1CtrlInventorySaveCANOpenLSSConfread-writecurrentNA
1.3.6.1.4.1.26854.3.2.1.16.3.83ScalarsiteV1CtrlInventoryStartNewInventoryread-writecurrentNA
1.3.6.1.4.1.26854.3.2.1.16.3.91ScalarsiteV1CtrlInventoryUpgradeNodeFirmwareread-writecurrentThis control element is used to start the firmware upgrade of a CAN bus Node. You need to upload first the firmware trough ftp in the /user/firmware path. Then…
1.3.6.1.4.1.26854.3.2.1.16.3.92ScalarsiteV1CtrlInventoryCancelFirmwareUpgraderead-writecurrentThis control element is used to cancel the running firmware upgrade of a CAN bus Node.
1.3.6.1.4.1.26854.3.2.1.16.3.103ScalarsiteV1CtrlFilesFlashBinaryread-writecurrentThis control element is used to start a binary flash update. You need to upload first the firmware trough ftp in the /user/firmware path.
1.3.6.1.4.1.26854.3.2.1.16.3.110ScalarsiteV1CtrlFilesDownloadFileFromUrlread-writecurrentThis control element is used to download a file wiht HTTP get, the argument is an url. The file is saved in the upload folder
1.3.6.1.4.1.26854.3.2.1.16.3.111ScalarsiteV1CtrlFilesDeleteUserUploadedFileread-writecurrentThis control element is used to delete a file in the user-upload folder. This is riskless as these files are not used, they are temporary files.
1.3.6.1.4.1.26854.3.2.1.16.3.112ScalarsiteV1CtrlFilesMoveUserUploadedFileread-writecurrentThis control element is used to copy a file from the user-upload folder to another one. Be aware of what your are doing !
1.3.6.1.4.1.26854.3.2.1.16.3.113ScalarsiteV1CtrlFilesExtractZipFileinuseruploadread-writecurrentThis control element is used to delete a file in the user-upload folder. This is riskless as these files are not used, they are temporary files.
1.3.6.1.4.1.26854.3.2.1.16.3.120ScalarsiteV1CtrlEmailSendSummaryEmailread-writecurrentThis control element is used to force the sending of a summary to the configured mail address
1.3.6.1.4.1.26854.3.2.1.16.3.250ScalarsiteV1CtrlScriptingControlLuaScriptread-writecurrentThis control element is used to control the lua scripting system. Available command are: enable[Enable Lua Capabilities], disable[Disable Lua Capabilities], re…
1.3.6.1.4.1.26854.3.2.1.16.3.300ScalarsiteV1CtrlControllerAdvancedFunctionGenericCommandExecutionread-writecurrentThis control is used to perform advanced operation.
1.3.6.1.4.1.26854.3.2.1.16.3.501ScalarsiteV1CtrlGenericClearMyEventsread-writecurrentBy writing '1' to this control element, all the events of this equipment will be cleared.
1.3.6.1.4.1.26854.3.2.1.16.3.502ScalarsiteV1CtrlGenericClearAllEventsread-writecurrentBy writing '1' to this control element, all the events of this equipment and all the events of all the sub-equipments will be cleared.
1.3.6.1.4.1.26854.3.2.1.16.3.511ScalarsiteV1CtrlGenericAddEventread-writecurrentThis control element adds an event of severity none. The event name is the text written to this control element
1.3.6.1.4.1.26854.3.2.1.16.3.512ScalarsiteV1CtrlGenericAddMajorEventread-writecurrentThis control element adds an event of severity major. The event name is the text written to this control element
1.3.6.1.4.1.26854.3.2.1.16.3.521ScalarsiteV1CtrlGenericResetDefaultNamesAndGroupsread-writecurrentThis control element resets all the element Names, Groups and Subgroups to default values for this equipment
1.3.6.1.4.1.26854.3.2.1.16.3.522ScalarsiteV1CtrlGenericResetDefaultNamesAndGroupsRecursiveread-writecurrentThis control element resets all the element Names, Groups and Subgroups to default values for this equipment and all sub equipments
1.3.6.1.4.1.26854.3.2.1.18NodesiteV1Notifications
1.3.6.1.4.1.26854.3.2.1.18.0NodesiteV1NotificationPrefix
1.3.6.1.4.1.26854.3.2.1.18.0.1NotificationsiteV1NotificationOfEventcurrentNotification generated when a new event appears
1.3.6.1.4.1.26854.3.2.1.19NodesiteV1Compliance
1.3.6.1.4.1.26854.3.2.1.19.1NodesiteV1ComplianceGroups
1.3.6.1.4.1.26854.3.2.1.19.1.1GroupsiteV1GlobalGroupcurrenttext
1.3.6.1.4.1.26854.3.2.1.19.1.2GroupsiteV1NotificationGroupcurrenttext
1.3.6.1.4.1.26854.3.2.1.19.2CompliancesiteV1FullCompliancecurrentThe compliance statement for SNMPV2 entities which implement the SNMPV2 MIB.
1.3.6.1.4.1.26854.3.2.1.20NodeenergySystems
1.3.6.1.4.1.26854.3.2.1.20.1Nodees1
1.3.6.1.4.1.26854.3.2.1.20.1.1Scalares1GlobalStatusread-onlycurrentA textual string (alarms, normal or unknown) containing the status of the Energy System
1.3.6.1.4.1.26854.3.2.1.20.1.2Scalares1GlobalAlarmSeverityTyperead-onlycurrentThe alarm severity type (critical, major, minor, warning, none, disabled) of the Energy System
1.3.6.1.4.1.26854.3.2.1.20.1.3Scalares1GlobalAlarmSeverityLevelread-onlycurrentThe alarm severity level (0-9) of the Energy System
1.3.6.1.4.1.26854.3.2.1.20.1.4Scalares1GlobalAlarmSeverityTypeIntread-onlycurrentThe alarm severity type as integer (critical=4, major=3, minor=2, warning=1, none=0) of the Energy System
1.3.6.1.4.1.26854.3.2.1.20.1.10Nodees1Description
1.3.6.1.4.1.26854.3.2.1.20.1.10.1Scalares1DescriptionNumberread-onlycurrentThe number of entries in the Energy System Description table
1.3.6.1.4.1.26854.3.2.1.20.1.10.2Tablees1DescriptionTablenot-accessiblecurrentThe Description table of the Energy System
1.3.6.1.4.1.26854.3.2.1.20.1.10.2.1Rowes1DescriptionEntrynot-accessiblecurrentA Description entry
1.3.6.1.4.1.26854.3.2.1.20.1.10.2.1.1Columnes1DescriptionIndexnot-accessiblecurrentDescription Index
1.3.6.1.4.1.26854.3.2.1.20.1.10.2.1.2Columnes1DescriptionNameread-onlycurrentDescription Name
1.3.6.1.4.1.26854.3.2.1.20.1.10.2.1.3Columnes1DescriptionValueread-createcurrentDescription Value
1.3.6.1.4.1.26854.3.2.1.20.1.10.2.1.4Columnes1DescriptionEntryStatusread-createcurrentThe status of this table entry
1.3.6.1.4.1.26854.3.2.1.20.1.10.3Nodees1DescriptionList
1.3.6.1.4.1.26854.3.2.1.20.1.10.3.1Scalares1DescDescriptionDescriptionread-writecurrentA free text zone to write a system description
1.3.6.1.4.1.26854.3.2.1.20.1.10.3.2Scalares1DescDescriptionReferenceread-writecurrentA free text zone to write the customer reference of the system
1.3.6.1.4.1.26854.3.2.1.20.1.11Nodees1Alarm
1.3.6.1.4.1.26854.3.2.1.20.1.11.1Scalares1AlarmNumberread-onlycurrentThe number of entries in the Energy System Alarm table
1.3.6.1.4.1.26854.3.2.1.20.1.11.2Tablees1AlarmTablenot-accessiblecurrentThe table of Alarm entries
1.3.6.1.4.1.26854.3.2.1.20.1.11.2.1Rowes1AlarmEntrynot-accessiblecurrentAn alarm entry
1.3.6.1.4.1.26854.3.2.1.20.1.11.2.1.1Columnes1AlarmIndexnot-accessiblecurrentAlarm Index
1.3.6.1.4.1.26854.3.2.1.20.1.11.2.1.2Columnes1AlarmNameread-onlycurrentAlarm Name
1.3.6.1.4.1.26854.3.2.1.20.1.11.2.1.3Columnes1AlarmActiveread-onlycurrentIs the Alarm active ? 'true' for active, 'false' for not-active
1.3.6.1.4.1.26854.3.2.1.20.1.11.2.1.4Columnes1AlarmSeverityTyperead-writecurrentThe alarm severity type (major, minor, warning, none, disabled) of this alarm entry
1.3.6.1.4.1.26854.3.2.1.20.1.11.2.1.5Columnes1AlarmSeverityLevelread-writecurrentThe alarm severity level (0-9) of this alarm entry
1.3.6.1.4.1.26854.3.2.1.20.1.11.2.1.6Columnes1AlarmStartTimeread-onlycurrentThe last start time of this alarm entry (null if never active)
1.3.6.1.4.1.26854.3.2.1.20.1.11.2.1.7Columnes1AlarmStopTimeread-onlycurrentThe last stop time of this alarm entry (null if alarm active)
1.3.6.1.4.1.26854.3.2.1.20.1.11.2.1.8Columnes1AlarmEntryStatusread-createcurrentThe status of this table entry - not used, only for MIB compliance
1.3.6.1.4.1.26854.3.2.1.20.1.11.3Scalares1AlarmSummaryread-onlycurrentSummary bit vector with all the alarms state of the Energy System. A '1' means alarm active, '0' means not active. Unimplemented alarms are always '0'.
1.3.6.1.4.1.26854.3.2.1.20.1.12Nodees1Event
1.3.6.1.4.1.26854.3.2.1.20.1.12.1Scalares1EventNumberread-onlycurrentThe number of entries in the Event Table related to the Energy System
1.3.6.1.4.1.26854.3.2.1.20.1.12.2Tablees1EventTablenot-accessiblecurrentThe Event table related to the Energy System
1.3.6.1.4.1.26854.3.2.1.20.1.12.2.1Rowes1EventEntrynot-accessiblecurrent.
1.3.6.1.4.1.26854.3.2.1.20.1.12.2.1.1Columnes1EventIndexnot-accessiblecurrentEvent Index
1.3.6.1.4.1.26854.3.2.1.20.1.12.2.1.2Columnes1EventIdread-onlycurrentEvent Index
1.3.6.1.4.1.26854.3.2.1.20.1.12.2.1.3Columnes1EventNameread-onlycurrentEvent Name
1.3.6.1.4.1.26854.3.2.1.20.1.12.2.1.4Columnes1EventDateTimeread-onlycurrentThe date and time of the event
1.3.6.1.4.1.26854.3.2.1.20.1.12.2.1.5Columnes1EventSeverityTyperead-onlycurrentThe event severity type ('major', 'minor', 'warning' or 'none')
1.3.6.1.4.1.26854.3.2.1.20.1.12.2.1.6Columnes1EventSeverityLevelread-onlycurrentThe event severity level (0-9)
1.3.6.1.4.1.26854.3.2.1.20.1.12.2.1.7Columnes1EventEntryStatusread-createcurrentThe status of this table entry
1.3.6.1.4.1.26854.3.2.1.20.1.13Nodees1Data
1.3.6.1.4.1.26854.3.2.1.20.1.13.1Scalares1DataNumberread-onlycurrentThe number of entries in the Data Table related to the Energy System
1.3.6.1.4.1.26854.3.2.1.20.1.15Nodees1Config
1.3.6.1.4.1.26854.3.2.1.20.1.15.1Scalares1ConfigNumberread-onlycurrentThe number of entries in the Config table related to the Energy System
1.3.6.1.4.1.26854.3.2.1.20.1.15.2Tablees1ConfigTablenot-accessiblecurrentThe table of Config entries related to the Energy System
1.3.6.1.4.1.26854.3.2.1.20.1.15.2.1Rowes1ConfigEntrynot-accessiblecurrentA Config entry
1.3.6.1.4.1.26854.3.2.1.20.1.15.2.1.1Columnes1ConfigIndexnot-accessiblecurrentThe Config entry Index
1.3.6.1.4.1.26854.3.2.1.20.1.15.2.1.2Columnes1ConfigNameread-onlycurrentThe Config entry name
1.3.6.1.4.1.26854.3.2.1.20.1.15.2.1.3Columnes1ConfigValueread-writecurrentThe Config entry value
1.3.6.1.4.1.26854.3.2.1.20.1.15.2.1.4Columnes1ConfigEntryStatusread-createcurrentThe status of this table entry - not used, only for compliance
1.3.6.1.4.1.26854.3.2.1.20.1.15.3Nodees1ConfigList
1.3.6.1.4.1.26854.3.2.1.20.1.15.3.100Scalares1CfgEnergyMeterNumberOfGenericPulseEnergyCounterread-writecurrentNA
1.3.6.1.4.1.26854.3.2.1.20.1.16Nodees1Control
1.3.6.1.4.1.26854.3.2.1.20.1.16.1Scalares1ControlNumberread-onlycurrentThe number of entries in the Control table related to the Energy System
1.3.6.1.4.1.26854.3.2.1.20.1.16.2Tablees1ControlTablenot-accessiblecurrentThe table of Control entries related to the Energy System
1.3.6.1.4.1.26854.3.2.1.20.1.16.2.1Rowes1ControlEntrynot-accessiblecurrentA Control entry
1.3.6.1.4.1.26854.3.2.1.20.1.16.2.1.1Columnes1ControlIndexnot-accessiblecurrentThe Control entry Index
1.3.6.1.4.1.26854.3.2.1.20.1.16.2.1.2Columnes1ControlNameread-onlycurrentThe Control entry name
1.3.6.1.4.1.26854.3.2.1.20.1.16.2.1.3Columnes1ControlValueread-writecurrentThe Control entry value
1.3.6.1.4.1.26854.3.2.1.20.1.16.2.1.4Columnes1ControlEntryStatusread-createcurrentThe status of this table entry - not used, only for compliance
1.3.6.1.4.1.26854.3.2.1.20.1.16.3Nodees1ControlList
1.3.6.1.4.1.26854.3.2.1.20.1.16.3.501Scalares1CtrlGenericClearMyEventsread-writecurrentBy writing '1' to this control element, all the events of this equipment will be cleared.
1.3.6.1.4.1.26854.3.2.1.20.1.16.3.502Scalares1CtrlGenericClearAllEventsread-writecurrentBy writing '1' to this control element, all the events of this equipment and all the events of all the sub-equipments will be cleared.
1.3.6.1.4.1.26854.3.2.1.20.1.16.3.511Scalares1CtrlGenericAddEventread-writecurrentThis control element adds an event of severity none. The event name is the text written to this control element
1.3.6.1.4.1.26854.3.2.1.20.1.16.3.512Scalares1CtrlGenericAddMajorEventread-writecurrentThis control element adds an event of severity major. The event name is the text written to this control element
1.3.6.1.4.1.26854.3.2.1.20.1.16.3.521Scalares1CtrlGenericResetDefaultNamesAndGroupsread-writecurrentThis control element resets all the element Names, Groups and Subgroups to default values for this equipment
1.3.6.1.4.1.26854.3.2.1.20.1.16.3.522Scalares1CtrlGenericResetDefaultNamesAndGroupsRecursiveread-writecurrentThis control element resets all the element Names, Groups and Subgroups to default values for this equipment and all sub equipments
1.3.6.1.4.1.26854.3.2.1.20.1.18Nodees1Notifications
1.3.6.1.4.1.26854.3.2.1.20.1.18.0Nodees1NotificationPrefix
1.3.6.1.4.1.26854.3.2.1.20.1.18.0.1Notificationes1NotificationOfEventcurrentNotification generated when a new event appears
1.3.6.1.4.1.26854.3.2.1.20.1.19Nodees1Compliance
1.3.6.1.4.1.26854.3.2.1.20.1.19.1Nodees1ComplianceGroups
1.3.6.1.4.1.26854.3.2.1.20.1.19.1.1Groupes1GlobalGroupcurrenttext
1.3.6.1.4.1.26854.3.2.1.20.1.19.1.2Groupes1NotificationGroupcurrenttext
1.3.6.1.4.1.26854.3.2.1.20.1.19.2Compliancees1FullCompliancecurrentThe compliance statement for SNMPV2 entities which implement the SNMPV2 MIB.
1.3.6.1.4.1.26854.3.2.1.20.1.20Nodees1DCSystems
1.3.6.1.4.1.26854.3.2.1.20.1.20.1Nodees1dc1
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.1Scalares1dc1GlobalStatusread-onlycurrentA textual string (alarms, normal or unknown) containing the status of the DC System
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.2Scalares1dc1GlobalAlarmSeverityTyperead-onlycurrentThe alarm severity type (critical, major, minor, warning, none, disabled) of the DC System
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.3Scalares1dc1GlobalAlarmSeverityLevelread-onlycurrentThe alarm severity level (0-9) of the DC System
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.4Scalares1dc1GlobalAlarmSeverityTypeIntread-onlycurrentThe alarm severity type as integer (critical=4, major=3, minor=2, warning=1, none=0) of the DC System
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10Nodees1dc1Description
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.1Scalares1dc1DescriptionNumberread-onlycurrentThe number of entries in the DC System Description table
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.2Tablees1dc1DescriptionTablenot-accessiblecurrentThe Description table of the DC System
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.2.1Rowes1dc1DescriptionEntrynot-accessiblecurrentA Description entry
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.2.1.1Columnes1dc1DescriptionIndexnot-accessiblecurrentDescription Index
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.2.1.2Columnes1dc1DescriptionNameread-onlycurrentDescription Name
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.2.1.3Columnes1dc1DescriptionValueread-createcurrentDescription Value
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.2.1.4Columnes1dc1DescriptionEntryStatusread-createcurrentThe status of this table entry
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3Nodees1dc1DescriptionList
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.1Scalares1dc1DescDescriptionDescriptionread-writecurrentA free text zone to write a system description
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.2Scalares1dc1DescDescriptionReferenceread-writecurrentA free text zone to write the customer reference of the system
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.11Scalares1dc1DescDescriptionProductNameread-onlycurrentThe product name of the DC system monitoring
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.12Scalares1dc1DescDescriptionHardwareReferenceread-onlycurrentThe hardware reference of the DC system monitoring
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.14Scalares1dc1DescDescriptionSoftwareReferenceread-onlycurrentThe software reference of the DC system monitoring
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.16Scalares1dc1DescDescriptionSerialNumberread-onlycurrentThe serial number of the DC system monitoring
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.18Scalares1dc1DescDescriptionManufacturingDateread-onlycurrentThe production date of the DC system monitoring
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.31Scalares1dc1DescDescriptionDistributionModuleProductNameread-onlycurrentThe product name of the Electronic Distribution/LVD Module
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.32Scalares1dc1DescDescriptionDistributionModuleHardwareReferenceread-onlycurrentThe hardware reference of the Electronic Distribution/LVD Module
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.34Scalares1dc1DescDescriptionDistributionModuleSoftwareReferenceread-onlycurrentThe software reference of the Electronic Distribution/LVD Module
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.36Scalares1dc1DescDescriptionDistributionModuleSerialNumberread-onlycurrentThe serial number of the Electronic Distribution/LVD Module
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.38Scalares1dc1DescDescriptionDistributionModuleManufacturingDateread-onlycurrentThe manufacturing date of the Electronic Distribution/LVD Module
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11Nodees1dc1Alarm
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.1Scalares1dc1AlarmNumberread-onlycurrentThe number of entries in the DC System Alarm table
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2Tablees1dc1AlarmTablenot-accessiblecurrentThe table of Alarm entries
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2.1Rowes1dc1AlarmEntrynot-accessiblecurrentAn alarm entry
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2.1.1Columnes1dc1AlarmIndexnot-accessiblecurrentAlarm Index
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2.1.2Columnes1dc1AlarmNameread-onlycurrentAlarm Name
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2.1.3Columnes1dc1AlarmActiveread-onlycurrentIs the Alarm active ? 'true' for active, 'false' for not-active
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2.1.4Columnes1dc1AlarmSeverityTyperead-writecurrentThe alarm severity type (major, minor, warning, none, disabled) of this alarm entry
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2.1.5Columnes1dc1AlarmSeverityLevelread-writecurrentThe alarm severity level (0-9) of this alarm entry
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2.1.6Columnes1dc1AlarmStartTimeread-onlycurrentThe last start time of this alarm entry (null if never active)
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2.1.7Columnes1dc1AlarmStopTimeread-onlycurrentThe last stop time of this alarm entry (null if alarm active)
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2.1.8Columnes1dc1AlarmEntryStatusread-createcurrentThe status of this table entry - not used, only for MIB compliance
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.3Scalares1dc1AlarmSummaryread-onlycurrentSummary bit vector with all the alarms state of the DC System. A '1' means alarm active, '0' means not active. Unimplemented alarms are always '0'.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12Nodees1dc1Event
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.1Scalares1dc1EventNumberread-onlycurrentThe number of entries in the Event Table related to the DC System
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.2Tablees1dc1EventTablenot-accessiblecurrentThe Event table related to the DC System
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.2.1Rowes1dc1EventEntrynot-accessiblecurrent.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.2.1.1Columnes1dc1EventIndexnot-accessiblecurrentEvent Index
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.2.1.2Columnes1dc1EventIdread-onlycurrentEvent Index
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.2.1.3Columnes1dc1EventNameread-onlycurrentEvent Name
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.2.1.4Columnes1dc1EventDateTimeread-onlycurrentThe date and time of the event
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.2.1.5Columnes1dc1EventSeverityTyperead-onlycurrentThe event severity type ('major', 'minor', 'warning' or 'none')
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.2.1.6Columnes1dc1EventSeverityLevelread-onlycurrentThe event severity level (0-9)
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.2.1.7Columnes1dc1EventEntryStatusread-createcurrentThe status of this table entry
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13Nodees1dc1Data
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.1Scalares1dc1DataNumberread-onlycurrentThe number of entries in the Data Table related to the DC System
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.2Tablees1dc1DataTablenot-accessiblecurrentThe table of Data entries
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.2.1Rowes1dc1DataEntrynot-accessiblecurrentA data entry
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.2.1.1Columnes1dc1DataIndexnot-accessiblecurrentThe data index
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.2.1.2Columnes1dc1DataNameread-onlycurrentThe data name
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.2.1.3Columnes1dc1DataValueread-onlycurrentThe data value
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.2.1.4Columnes1dc1DataEntryStatusread-createcurrentThe status of this table entry - not used, only present for compliance
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3Nodees1dc1DataList
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.1Scalares1dc1DataSystemDCModeread-onlycurrentThe DC system can have 5 values: 'Float'(0), 'Equalize'(1), 'Battery Test'(2), 'Ac Failure'(3) or 'Safe'(5)
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.2Scalares1dc1DataSystemPreviousDCModeread-onlycurrentThe previous value of the DC Mode : 'Float'(0), 'Equalize'(1), 'Battery Test'(2), 'Ac Failure'(3) or 'Safe'(5)
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.5Scalares1dc1DataSystemNiMHChargeModeread-onlycurrentNA
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.11Scalares1dc1DataDCBusBusVoltageread-onlycurrentThe DC bus voltage in volt.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.12Scalares1dc1DataSystemRatioDeliveredOnAvailablePowerread-onlycurrentThis is the ratio of the delivered power divided by the installed power, in %.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.13Scalares1dc1DataACBusMinutesSinceLastACFailBeginread-onlycurrentThe number of minute since the last AC Failure begin
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.14Scalares1dc1DataACBusMinutesSinceLastACFailEndread-onlycurrentThe number of minute since the last AC Failure end
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.21Scalares1dc1DataRectifiersRectifiersOutPowerread-onlycurrentThe sum of the delivered rectifier power
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.22Scalares1dc1DataRectifiersRectifiersOutCurrentread-onlycurrentThe sum of the delivered rectifier current
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.23Scalares1dc1DataRectifiersRectifiersOutPowerMaxread-onlycurrentThe sum of the deliverable rectifier power
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.24Scalares1dc1DataRectifiersRectifiersOutCurrentMaxread-onlycurrentThe sum of the deliverable rectifier current
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.31Scalares1dc1DataRectifiersNumberOfRectifierMaxread-onlycurrentThe maximum possible number of rectifier in this dc system
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.32Scalares1dc1DataRectifiersNumberOfPresentRectifierread-onlycurrentThe actual number of present rectifier in this dc system
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.33Scalares1dc1DataRectifiersNumberOfAbsentRectifierread-onlycurrentThe actual number of absent rectifier in this dc system
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.34Scalares1dc1DataRectifiersNumberOfActiveRectifierread-onlycurrentThe actual number of active rectifier in this dc system. An active rectifier is a rectifier which is present, DC OK, AC OK and not in remote off.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.35Scalares1dc1DataRectifiersNumberOfACFailRectifierread-onlycurrentThe actual number or rectifier in AC Failure.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.36Scalares1dc1DataRectifiersNumberOfDCFailRectifierread-onlycurrentThe actual number or rectifier with DC Failure.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.37Scalares1dc1DataRectifiersNumberOfRemoteOffRectifierread-onlycurrentThe actual number or rectifier in remote off.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.38Scalares1dc1DataRectifiersNumberOfOverTempRectifierread-onlycurrentThe actual number or rectifier in Over Temperature.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.51Scalares1dc1DataLoadLoadPowerread-onlycurrentEstimation of the load power consumption
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.52Scalares1dc1DataLoadLoadCurrentread-onlycurrentEstimation of the load current consumption
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.61Scalares1dc1DataBatBatInputCurrentread-onlycurrentMeasurement of the battery input current. A negative value means that the battery is discharging
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.62Scalares1dc1DataBatBatInputPowerread-onlycurrentMeasurement of the battery input power. A negative value means that the battery is discharging
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.71Scalares1dc1DataBatBatTempread-onlycurrentThe battery temperature
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.72Scalares1dc1DataBatBatTestStateread-onlycurrentThis is about the result of the last battery test. 10 values are possible : 'Never Tested'(0), 'Success'(1), 'On Going'(2), 'Failed: Timeout'(3), 'Failed: Vbus…
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.73Scalares1dc1DataBatLastBatTestDischargedCapacityRatioread-onlycurrentThis is the battery capacity, in percent, discharged during the last battery test. This value is updated at the end of the battery test.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.74Scalares1dc1DataBatLastBatTestDischargedCapacityread-onlycurrentThis is the battery capacity, in ampere hour, discharged during the last battery test. This value is updated at the end of the battery test.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.75Scalares1dc1DataBatLastBatTestFinalVoltageread-onlycurrentThis is the bus voltage at the end of the last battery test. This value is updated at the end of the battery test.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.76Scalares1dc1DataBatBatTestDurationread-onlycurrentThe duration of the last battery test. This value is updated at the end of the battery test. This value can't be higher than 1440 minutes (24 hours).
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.77Scalares1dc1DataBatPreviousBatTestDischargedCapacityRatioread-onlycurrentThis is the battery capacity, in percent, discharged during the previous battery test. This value is shifted at the end of the battery test.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.78Scalares1dc1DataBatPreviousBatTestDischargedCapacityread-onlycurrentThis is the battery capacity, in ampere hour, discharged during the previous battery test. This value is shifted at the end of the battery test.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.79Scalares1dc1DataBatPreviousBatTestFinalVoltageread-onlycurrentThis is the bus voltage at the end of the previous battery test. This value is shifted at the end of the battery test.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.80Scalares1dc1DataBatPreviousBatTestDurationread-onlycurrentThe duration of the previous battery test. This value is shifted at the end of the battery test. This value can't be higher than 1440 minutes (24 hours).
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.81Scalares1dc1DataBatPreviousBatTestStateread-onlycurrentThe result of the previous battery test - 10 values are possible: 'Never Tested'(0), 'Success'(1), 'On Going'(2), 'Failed: Timeout'(3), 'Failed: Vbus Too Low'(…
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.82Scalares1dc1DataBatMinutesSinceLastTestBatread-onlycurrentThe number of minute since the end of last battery test
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.84Scalares1dc1DataBatNextScheduledBatTestread-onlycurrentThe date and time of the next time the scheduled battery test will run
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.91Scalares1dc1DataBatBatChargeCapacityread-onlycurrentThe battery charge capacity, calculated by integration of the current.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.92Scalares1dc1DataBatCalculatedAutonomyread-onlycurrentCalculation of the remaining autonomy. This value can change following the load of your system and the maximal depth of dicharge configuration (CF39).
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.94Scalares1dc1DataBatBatCurrentIntegrationread-onlycurrentActual value of the integration of the current, in Ampere * hour
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.101Scalares1dc1DataLVDLVDStateread-onlycurrentActual state of the LVD
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.111Scalares1dc1DataRelsRel1Stateread-onlycurrentActual state of the Relay 1
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.112Scalares1dc1DataRelsRel2Stateread-onlycurrentActual state of the Relay 2
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.113Scalares1dc1DataRelsRel3Stateread-onlycurrentActual state of the Relay 3
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.114Scalares1dc1DataRelsRel4Stateread-onlycurrentActual state of the Relay 3
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.121Scalares1dc1DataSmartEnergyEfficiencyOptimizedNumberOfRectifierread-onlycurrentThe optimal number of ON rectifier for Efficiency Optimization
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.122Scalares1dc1DataSmartEnergySystemLossWithoutOptimisationread-onlycurrentEstimation of the losses without optimisation
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.123Scalares1dc1DataSmartEnergySystemLossWithOptimisationread-onlycurrentEstimation of the losses with optimisation
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.124Scalares1dc1DataSmartEnergyRectifierModelUsedForCalculationread-onlycurrentThe rectifier model used
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.125Scalares1dc1DataSmartEnergySmartEnergySavingsread-onlycurrentEstimation of the losses with optimisation
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.151Scalares1dc1DataSensorsAmbientTempread-onlycurrentThe ambiant temperature (second temperature sense)
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.204Scalares1dc1DataSensorsPulseCounter4read-onlycurrentThe counter value of the digital input 4.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15Nodees1dc1Config
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.1Scalares1dc1ConfigNumberread-onlycurrentThe number of entries in the Config table related to the DC System
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.2Tablees1dc1ConfigTablenot-accessiblecurrentThe table of Config entries related to the DC System
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.2.1Rowes1dc1ConfigEntrynot-accessiblecurrentA Config entry
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.2.1.1Columnes1dc1ConfigIndexnot-accessiblecurrentThe Config entry Index
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.2.1.2Columnes1dc1ConfigNameread-onlycurrentThe Config entry name
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.2.1.3Columnes1dc1ConfigValueread-writecurrentThe Config entry value
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.2.1.4Columnes1dc1ConfigEntryStatusread-createcurrentThe status of this table entry - not used, only for compliance
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3Nodees1dc1ConfigList
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.1Scalares1dc1CfgDCBusDCBusFloatVoltageat25degCread-writecurrentThe floating dc bus voltage of the system at 25 Celsius degree
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.2Scalares1dc1CfgDCBusDCBusVoltageExtraLowread-writecurrentThe bus voltage under which the alarm 'DC Bus Voltage Extra Low' is set.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.3Scalares1dc1CfgDCBusDCBusVoltageExtraLowHysteresisread-writecurrentThe voltage hysteresis on the alarm 'DC Bus Voltage Extra Low'.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.4Scalares1dc1CfgDCBusDCBusVoltageLowread-writecurrentThe bus voltage under which the alarm 'DC Bus Voltage Low' is set.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.5Scalares1dc1CfgDCBusDCBusVoltageLowHysteresisread-writecurrentThe voltage hysteresis on the alarm 'DC Bus Voltage Low
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.6Scalares1dc1CfgDCBusDCBusVoltageHighread-writecurrentThe bus voltage over which the alarm 'DC Bus Voltage High' is set.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.7Scalares1dc1CfgDCBusDCBusVoltageHighHysteresisread-writecurrentThe voltage hysteresis on the alarm 'DC Bus Voltage High
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.8Scalares1dc1CfgDCBusDCBusVoltageExtraHighread-writecurrentThe bus voltage over which the alarm 'DC Bus Voltage Extra High' is set.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.9Scalares1dc1CfgDCBusDCBusVoltageExtraHighHysteresisread-writecurrentThe voltage hysteresis on the alarm 'DC Bus Voltage Extra High
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.10Scalares1dc1CfgLVDLVDDisconnectVoltageread-writecurrentThe dc bus voltage under which the battery must be disconnected of the bus. This allows preserving the battery life. The load will be unpowered. This value has…
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.11Scalares1dc1CfgLVDLVDDisconnectDelayread-writecurrentThe delay in second before disconnecting the battery if the dc bus voltage is under the configured disconnected voltage. This avoids disconnection during a low…
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.21Scalares1dc1CfgBatTempCompensationSloperead-writecurrentThe slope of the battery temperature compensation in mv/degree. For a 48V system, -72mV/degree is often used.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.22Scalares1dc1CfgBatMaxPosTempCompensationread-writecurrentThe maximal allowed positive compensation.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.23Scalares1dc1CfgBatMaxNegTempCompensationread-writecurrentThe maximal allowed negative compensation.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.25Scalares1dc1CfgRectifiersMinimalNumberOfPresentRectifiersread-writecurrentThe minimal number of rectifier which must be present. If there is less present rectifiers, the alarm 'Missing Rectifiers' is set.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.26Scalares1dc1CfgRectifiersRectifierModelread-writecurrentThe rectifier model
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.27Scalares1dc1CfgRectifiersForcedRemoteOffRectifersread-writecurrentA list of rectifier which are forced in remote off. The id of the rectifier must be coma separated. Ex: 1,3 will maintain rectifier 1 and 3 off.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.31Scalares1dc1CfgBatBatChargeCurrentLimitread-writecurrentThe maximal battery current when the battery is charging. The monitoring regulates the bus voltage in order to satisfy this condition. This parameter is often …
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.32Scalares1dc1CfgBatBatStringCapacityread-writecurrentThe battery capacity in Ah.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.33Scalares1dc1CfgBatBatTempLowread-writecurrentThe temperature under which the alarm 'Battery Temperature Too Low' must be set.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.34Scalares1dc1CfgBatBatTempHighread-writecurrentThe temperature over which the alarm 'Battery Temperature Too High' must be set.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.35Scalares1dc1CfgBatBatTempHysteresisread-writecurrentThe hysteresis on the 'Battery Temperature Too High' and 'Battery Temperature Too Low' alarms.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.36Scalares1dc1CfgBatMinimalCurrentForDischargingAlarmread-writecurrentThe minimal discharging current to set the 'Battery On Discharge' alarm.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.37Scalares1dc1CfgBatCurrentHysteresisForDischargingAlarmread-writecurrentThe hysteresis on the 'Battery On Discharge' alarm.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.38Scalares1dc1CfgBatPeukertNumberread-writecurrentThe Peukert number relates to the internal resistance of a battery and provides an indication of the excpected capacity. The ideal number is 1. This value can …
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.39Scalares1dc1CfgBatMaxDepthOfDischargeforAutonomyEstimationread-writecurrentIt is generally recommended to discharge maximum 60% of the battery capacity to enhance battery lifetime. By default, 100% is used for autonomy calculation. Th…
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.51Scalares1dc1CfgBatBoostAutomaticread-writecurrentThe boost mode must be automatically after the fact that during a mains failure, the bus voltage went under the configured 'Boost Activation Low Voltage'. This…
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.52Scalares1dc1CfgBatBoostActivationLowVoltageread-writecurrentThe voltage under which the boost mode can be activated.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.53Scalares1dc1CfgBatBoostTerminationVoltageread-writecurrentThe voltage over which the system must go back to floating mode.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.54Scalares1dc1CfgBatBoostTerminationCurrentread-writecurrentThe battery charging current under which the system must go back to floating mode.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.55Scalares1dc1CfgBatBoostTerminationTimeread-writecurrentThe time in minute after which the system must go back in floating mode.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.69Scalares1dc1CfgBatBatTestTyperead-writecurrentType of the battery test: <br> Capacity based: The battery must give the requested capacity before falling lower than a value <br>Time Based: The battery must …
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.70Scalares1dc1CfgBatBatTestEndVoltageread-writecurrentThe voltage at which any battery test must be stopped. This value has to be higher than the LVD Disconnect voltage (CF10)
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.71Scalares1dc1CfgBatBatTestDischargeRatioread-writecurrentThe ratio of the battery capacity to discharge. If 30 is set, 30% of the battery will be discharged during the test
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.72Scalares1dc1CfgBatBatTestIntervalread-writecurrentThe number of days between two automatically started battery test. If this parameter is set to 0, the battery test is not started automatically. The user can r…
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.73Scalares1dc1CfgBatBatTestDischargeCurrentread-writecurrentThe current at which the battery must be discharged during a battery test. The monitoring regulates the bus voltage in order to satisfy this condition. The loa…
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.74Scalares1dc1CfgBatBatTestMinimalDischargeCurrentread-writecurrentThe battery current under which the battery test must be stopped because the load is too low.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.75Scalares1dc1CfgBatBatTestDurationread-writecurrentThe timeout in minute after which the battery test must be stopped.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.76Scalares1dc1CfgBatBatTestRequMinutesWithoutMainsFailread-writecurrentThe minimal time in minute without mains failure in order to allow a battery start. This parameter is not taken into account when the battery test is forced.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.77Scalares1dc1CfgBatBatTestSchedulerCronRuleread-writecurrentNA
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.83Scalares1dc1CfgSmartEnergySmartEnergyBooleanCondread-writecurrentThis is the boolean condition which allows or not to automatically optimize the number of rectifier in remote off.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.86Scalares1dc1CfgLVDBatLVDNodeIdread-writecurrentThis is a list of the node id of the Smart Electronic LVDs, coma separated
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.91Scalares1dc1CfgDigInputsDigInput1Nameread-writecurrentThe name of the digital input 1
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.92Scalares1dc1CfgDigInputsDigInput1NormallyClosedread-writecurrentTrue/False value defining if the digital input 1 is normally closed. If this digital input is not in this default state, the related alarm is set.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.93Scalares1dc1CfgDigInputsDigInput2Nameread-writecurrentThe name of the digital input 2
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.94Scalares1dc1CfgDigInputsDigInput2NormallyClosedread-writecurrentTrue/False value defining if the digital input 2 is normally closed. If this digital input is not in this default state, the related alarm is set.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.95Scalares1dc1CfgDigInputsDigInput3Nameread-writecurrentThe name of the digital input 3
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.96Scalares1dc1CfgDigInputsDigInput3NormallyClosedread-writecurrentTrue/False value defining if the digital input 3 is normally closed. If this digital input is not in this default state, the related alarm is set.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.97Scalares1dc1CfgDigInputsDigInput4Nameread-writecurrentThe name of the digital input 4
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.98Scalares1dc1CfgDigInputsDigInput4NormallyClosedread-writecurrentTrue/False value defining if the digital input 4 is normally closed. If this digital input is not in this default state, the related alarm is set.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.99Scalares1dc1CfgDigInputsDigInput5Nameread-writecurrentThe name of the digital input 5
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.100Scalares1dc1CfgDigInputsDigInput5NormallyClosedread-writecurrentTrue/False value defining if the digital input 5 is normally closed. If this digital input is not in this default state, the related alarm is set.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.101Scalares1dc1CfgDigInputsDigInput6Nameread-writecurrentThe name of the digital input 6
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.102Scalares1dc1CfgDigInputsDigInput6NormallyClosedread-writecurrentTrue/False value defining if the digital input 6 is normally closed. If this digital input is not in this default state, the related alarm is set.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.111Scalares1dc1CfgRelsDryAlarm1AlternativeBooleanCondread-writecurrentAnother Boolean condition to activate the dry alarm relay 1. The way to define boolean condition is detailed in the PLC chapter.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.112Scalares1dc1CfgRelsDryAlarm2AlternativeBooleanCondread-writecurrentAnother Boolean condition to activate the dry alarm relay 2. The way to define boolean condition is detailed in the PLC chapter.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.113Scalares1dc1CfgRelsDryAlarm3AlternativeBooleanCondread-writecurrentAnother Boolean condition to activate the dry alarm relay 3. The way to define boolean condition is detailed in the PLC chapter.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.114Scalares1dc1CfgRelsDryAlarm4AlternativeBooleanCondread-writecurrentAnother Boolean condition to activate the dry alarm relay 4. The way to define boolean condition is detailed in the PLC chapter.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.131Scalares1dc1CfgSensorsAmbientTempLowread-writecurrentThe temperature under which the alarm 'Ambiant Temperature Too Low' must be set.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.132Scalares1dc1CfgSensorsAmbientTempHighread-writecurrentThe temperature under which the alarm 'Ambiant Temperature Too Low' must be set.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.133Scalares1dc1CfgSensorsAmbientTempHysteresisread-writecurrentThe hysteresis on the 'Battery Temperature Too High' and 'Battery Temperature Too Low' alarms.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.521Scalares1dc1CfgGenericReadAccessUserNumbersread-writecurrentThe list of the user numbers which have read access to this equipment. The user numbers are coma separated. The accepted user id are 1,2,3,4 and 5. Ex: 1,3,4
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.522Scalares1dc1CfgGenericWriteAccessUserNumbersread-writecurrentThe list of the user numbers which have write access to this equipment. This means that these users can modify the configuration element, the alarm settings an…
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.601Scalares1dc1CfgGenericEventTableLengthread-writecurrentThe maximum length of the table. The value must be comprised between 10 and 4000
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.602Scalares1dc1CfgGenericEventTableLengthByRectifierread-writecurrentThe maximum length of the table. The value must be comprised between 10 and 4000
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.901Scalares1dc1CfgPLCNumberOfPLCDataread-writecurrentThe number of PLC data. Every equipment can manage up to 30 user programmable data. Data elements are automatically added in the data table. Configuration para…
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.902Scalares1dc1CfgPLCNumberOfPLCAlarmread-writecurrentThe number of PLC alarm. Every equipment can manage up to 30 user programmable alarms. Alarm elements are automatically added in the alarm table. The alarm par…
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16Nodees1dc1Control
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.1Scalares1dc1ControlNumberread-onlycurrentThe number of entries in the Control table related to the DC System
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.2Tablees1dc1ControlTablenot-accessiblecurrentThe table of Control entries related to the DC System
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.2.1Rowes1dc1ControlEntrynot-accessiblecurrentA Control entry
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.2.1.1Columnes1dc1ControlIndexnot-accessiblecurrentThe Control entry Index
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.2.1.2Columnes1dc1ControlNameread-onlycurrentThe Control entry name
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.2.1.3Columnes1dc1ControlValueread-writecurrentThe Control entry value
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.2.1.4Columnes1dc1ControlEntryStatusread-createcurrentThe status of this table entry - not used, only for compliance
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3Nodees1dc1ControlList
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.1Scalares1dc1CtrlSystemBackToFloatread-writecurrentThe dc system must go back in floating mode.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.2Scalares1dc1CtrlSystemStartBatTestread-writecurrentThe dc system must start a battery test.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.3Scalares1dc1CtrlSystemForceBatTestread-writecurrentThe dc system must force a battery test.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.4Scalares1dc1CtrlSystemStartBoostModeread-writecurrentThe dc system must go in boost mode.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.11Scalares1dc1CtrlLVDOpenTheLVDread-writecurrentTry to open the LVD. It could not work if the LVD is electronic, and the request will be canceled after 15 sec.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.12Scalares1dc1CtrlLVDCloseTheLVDread-writecurrentThe LVD must be closed
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.21Scalares1dc1CtrlBatCorrectBatCurrentOffsetread-writecurrentNA
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.41Scalares1dc1CtrlBatResetLastBatTestStateread-writecurrentReset the state of the last battery test. If an alarm 'Battery Last Test Failed' is set, the alarm will be cleared.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.51Scalares1dc1CtrlSaveSaveConfInMCUread-writecurrentSave configuration parameters in the MCU microcontroller. If comp@s is not present, the system will be correctly managed.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.55Scalares1dc1CtrlAdvancedSetMCUSpecificConfIdread-writecurrentThis control allows to reconfigure the MCU to support specific hardware configuration, with embedded distribution for example
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.61Scalares1dc1CtrlDigInputsSetDigInput4CounterValueread-writecurrentSet Counter Value
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.111Scalares1dc1CtrlRelsInvertRel1StateForXSecondsread-writecurrentGenerate Pulse on relay 1
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.112Scalares1dc1CtrlRelsInvertRel2StateForXSecondsread-writecurrentGenerate Pulse on relay 2
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.113Scalares1dc1CtrlRelsInvertRel3StateForXSecondsread-writecurrentGenerate Pulse on relay 3
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.114Scalares1dc1CtrlRelsInvertRel4StateForXSecondsread-writecurrentGenerate Pulse on relay 4
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.501Scalares1dc1CtrlGenericClearMyEventsread-writecurrentBy writing '1' to this control element, all the events of this equipment will be cleared.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.502Scalares1dc1CtrlGenericClearAllEventsread-writecurrentBy writing '1' to this control element, all the events of this equipment and all the events of all the sub-equipments will be cleared.
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.511Scalares1dc1CtrlGenericAddEventread-writecurrentThis control element adds an event of severity none. The event name is the text written to this control element
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.512Scalares1dc1CtrlGenericAddMajorEventread-writecurrentThis control element adds an event of severity major. The event name is the text written to this control element
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.521Scalares1dc1CtrlGenericResetDefaultNamesAndGroupsread-writecurrentThis control element resets all the element Names, Groups and Subgroups to default values for this equipment
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.522Scalares1dc1CtrlGenericResetDefaultNamesAndGroupsRecursiveread-writecurrentThis control element resets all the element Names, Groups and Subgroups to default values for this equipment and all sub equipments
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.18Nodees1dc1Notifications
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.18.0Nodees1dc1NotificationPrefix
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.18.0.1Notificationes1dc1NotificationOfEventcurrentNotification generated when a new event appears
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.19Nodees1dc1Compliance
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.19.1Nodees1dc1ComplianceGroups
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.19.1.1Groupes1dc1GlobalGroupcurrenttext
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.19.1.2Groupes1dc1NotificationGroupcurrenttext
1.3.6.1.4.1.26854.3.2.1.20.1.20.1.19.2Compliancees1dc1FullCompliancecurrentThe compliance statement for SNMPV2 entities which implement the SNMPV2 MIB.
1.3.6.1.4.1.26854.3.2.1.20.1.25Nodees1InverterSystems
1.3.6.1.4.1.26854.3.2.1.20.1.28Nodees1RemotePowerFeedingSystems
1.3.6.1.4.1.26854.3.2.1.21Nodeextensions