SITEBOSS-350-STD-MIB

1653 objects
MIB module for managing Asentria SiteBoss 350
Imported Objects
ASENTRIA-ROOT-MIBasentria
SNMPv2-SMIInteger32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE TimeTicks
SNMPv2-TCDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.3052.18Identitys350MIB module for managing Asentria SiteBoss 350
1.3.6.1.4.1.3052.18.0Nodes350Notifications
1.3.6.1.4.1.3052.18.0.110Notifications350StockContactClosureTrapcurrentA stock contact closure trap is issued when a contact closure event happens.
1.3.6.1.4.1.3052.18.0.120Notifications350StockTempTrapcurrentA stock temperature trap is issued when a temperature event happens.
1.3.6.1.4.1.3052.18.0.130Notifications350StockHumidityTrapcurrentA stock humidity trap is issued when a humidity event happens.
1.3.6.1.4.1.3052.18.0.140Notifications350StockAnalogTrapcurrentA stock analog trap is issued when an analog sensor event happens.
1.3.6.1.4.1.3052.18.0.150Notifications350StockOutputTrapcurrentA stock output trap is issued when an output event happens. That is, depending on the configuration, when an output changes state for any reason, this trap wil…
1.3.6.1.4.1.3052.18.0.180Notifications350StockPDCurrentTrapcurrentA stock analog trap is issued when a power distribution current event happens.
1.3.6.1.4.1.3052.18.0.190Notifications350StockPDVoltageTrapcurrentA stock analog trap is issued when a power distribution voltage event happens.
1.3.6.1.4.1.3052.18.0.210Notifications350StockPDFuseTrapcurrentA stock analog trap is issued when a power distribution fuse event happens.
1.3.6.1.4.1.3052.18.0.506Notifications350StockSchedTrapcurrentThe stock scheduled alarm trap is issued when the current time reaches the scheduled alarm time.
1.3.6.1.4.1.3052.18.0.507Notifications350StockImmediateTrapcurrentThe stock immediate alarm trap is issued when the user enters the DOTRAP command.
1.3.6.1.4.1.3052.18.0.510Notifications350StockCTSTrapcurrentA stock CTS trap is issued when an RS-232 CTS event happens.
1.3.6.1.4.1.3052.18.0.511Notifications350CPEDownTrapcurrentA stock CPE Down trap is issued when a CPE Down event happens.
1.3.6.1.4.1.3052.18.0.515Notifications350FuelSensorDisconnectTrapcurrentA stock Fuel Sensor Disconnect trap is issued when a Fuel Sensor Disconnect or Connect (Return to Normal) event happens.
1.3.6.1.4.1.3052.18.0.519Notifications350FuelSensorVolumeTrapcurrentA stock Fuel Sensor Volume trap is issued when a Fuel Sensor Volume event happens
1.3.6.1.4.1.3052.18.0.520Notifications350ACPowerMonitorAvgVoltageTrapcurrentA stock AC power monitor average voltage trap is issued when an AC power monitor average voltage event happens.
1.3.6.1.4.1.3052.18.0.521Notifications350ACPowerMonitorAvgCurrentTrapcurrentA stock AC power monitor average current trap is issued when an AC power monitor average current event happens.
1.3.6.1.4.1.3052.18.0.522Notifications350ACPowerMonitorFrequencyTrapcurrentA stock AC power monitor frequency trap is issued when an AC power monitor frequency event happens.
1.3.6.1.4.1.3052.18.0.523Notifications350ACPowerMonitorTRPTrapcurrentA stock AC power monitor TRP (total real power) trap is issued when an AC power monitor TRP event happens.
1.3.6.1.4.1.3052.18.0.524Notifications350ACPowerMonitorDisconnectTrapcurrentA stock AC power monitor disconnect trap is issued when an AC power monitor disconnect event happens.
1.3.6.1.4.1.3052.18.0.526Notifications350StockScriptTrapcurrentA stock script trap is issued when a script triggers an event via a_lib.PostEvent() called with no trap number (or this trap number) specified.
1.3.6.1.4.1.3052.18.0.527Notifications350FuelSensorVolumeSuddenChangeTrapcurrentA stock Fuel Sensor Volume Sudden Change trap is issued when a Fuel Sensor Volume Sudden Change event happens
1.3.6.1.4.1.3052.18.0.528Notifications350FuelSensorVolumeSlowChangeTrapcurrentA stock Fuel Sensor Volume Slow Change trap is issued when a Fuel Sensor Volume Slow Change event happens
1.3.6.1.4.1.3052.18.0.530Notifications350BattMonStringTemperatureTrapcurrentA stock Battery Monitor String Temperature trap is issued when a Battery Monitor String Temperature event happens.
1.3.6.1.4.1.3052.18.0.531Notifications350BattMonStringDiffTemperatureTrapcurrentA stock Battery Monitor String Differential Temperature trap is issued when a Battery Monitor String Differential Temperature event happens.
1.3.6.1.4.1.3052.18.0.532Notifications350BattMonStringVoltageTrapcurrentA stock Battery Monitor String Voltage trap is issued when a Battery Monitor String Voltage event happens.
1.3.6.1.4.1.3052.18.0.533Notifications350BattMonStringChargeLevelTrapcurrentA stock Battery Monitor String Charge Level trap is issued when a Battery Monitor String Charge Level event happens.
1.3.6.1.4.1.3052.18.0.534Notifications350BattMonStringChargingCurrentTrapcurrentA stock Battery Monitor String Charging Current trap is issued when a Battery Monitor String Charging Current event happens.
1.3.6.1.4.1.3052.18.0.535Notifications350BattMonStringDischargingCurrentTrapcurrentA stock Battery Monitor String Discharging Current trap is issued when a Battery Monitor String Discharging Current event happens.
1.3.6.1.4.1.3052.18.0.536Notifications350GeneratorNonStartTrapcurrentA stock Generator Non-start trap is issued when the unit commands the generator to start as part of the generator exercising feature, and the generator fails t…
1.3.6.1.4.1.3052.18.0.537Notifications350BattMonStringDifferentialVoltageTrapcurrentA stock Battery Monitor String Differential Voltage trap is issued when a Battery Monitor String Differential Voltage event happens.
1.3.6.1.4.1.3052.18.0.538Notifications350BattMonStringJarHealthTrapcurrentA stock Battery Monitor String Jar Health trap is issued when a Battery Monitor String Jar Health event happens.
1.3.6.1.4.1.3052.18.0.539Notifications350CameraTrapcurrentA stock camera trap is issued when a camera event happens.
1.3.6.1.4.1.3052.18.0.540Notifications350ACTotalPowerFactorTrapcurrentA stock AC power monitor total power factor trap is issued when an AC power monitor total power factor event happens.
1.3.6.1.4.1.3052.18.0.541Notifications350LocationTrapcurrentA stock location trap is issued when a location event happens.
1.3.6.1.4.1.3052.18.0.542Notifications350SleepTrapcurrentA stock sleep trap is issued when a sleep event happens.
1.3.6.1.4.1.3052.18.0.543Notifications350ResetTrapcurrentA stock reset trap is issued when a reset event happens.
1.3.6.1.4.1.3052.18.0.544Notifications350FuelSensorLevelsAutoAdjustTrapcurrentA stock fuel sensor levels auto-adjust trap is issued when a fuel sensor levels auto-adjust event happens.
1.3.6.1.4.1.3052.18.0.547Notifications350AccessControlTrapcurrentA stock access control trap is issued when an access control device management event happens.
1.3.6.1.4.1.3052.18.0.1000Notifications350UserTrap1000currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1000.
1.3.6.1.4.1.3052.18.0.1001Notifications350UserTrap1001currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1001.
1.3.6.1.4.1.3052.18.0.1002Notifications350UserTrap1002currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1002.
1.3.6.1.4.1.3052.18.0.1003Notifications350UserTrap1003currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1003.
1.3.6.1.4.1.3052.18.0.1004Notifications350UserTrap1004currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1004.
1.3.6.1.4.1.3052.18.0.1005Notifications350UserTrap1005currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1005.
1.3.6.1.4.1.3052.18.0.1006Notifications350UserTrap1006currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1006.
1.3.6.1.4.1.3052.18.0.1007Notifications350UserTrap1007currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1007.
1.3.6.1.4.1.3052.18.0.1008Notifications350UserTrap1008currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1008.
1.3.6.1.4.1.3052.18.0.1009Notifications350UserTrap1009currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1009.
1.3.6.1.4.1.3052.18.0.1010Notifications350UserTrap1010currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1010.
1.3.6.1.4.1.3052.18.0.1011Notifications350UserTrap1011currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1011.
1.3.6.1.4.1.3052.18.0.1012Notifications350UserTrap1012currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1012.
1.3.6.1.4.1.3052.18.0.1013Notifications350UserTrap1013currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1013.
1.3.6.1.4.1.3052.18.0.1014Notifications350UserTrap1014currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1014.
1.3.6.1.4.1.3052.18.0.1015Notifications350UserTrap1015currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1015.
1.3.6.1.4.1.3052.18.0.1016Notifications350UserTrap1016currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1016.
1.3.6.1.4.1.3052.18.0.1017Notifications350UserTrap1017currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1017.
1.3.6.1.4.1.3052.18.0.1018Notifications350UserTrap1018currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1018.
1.3.6.1.4.1.3052.18.0.1019Notifications350UserTrap1019currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1019.
1.3.6.1.4.1.3052.18.0.1020Notifications350UserTrap1020currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1020.
1.3.6.1.4.1.3052.18.0.1021Notifications350UserTrap1021currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1021.
1.3.6.1.4.1.3052.18.0.1022Notifications350UserTrap1022currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1022.
1.3.6.1.4.1.3052.18.0.1023Notifications350UserTrap1023currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1023.
1.3.6.1.4.1.3052.18.0.1024Notifications350UserTrap1024currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1024.
1.3.6.1.4.1.3052.18.0.1025Notifications350UserTrap1025currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1025.
1.3.6.1.4.1.3052.18.0.1026Notifications350UserTrap1026currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1026.
1.3.6.1.4.1.3052.18.0.1027Notifications350UserTrap1027currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1027.
1.3.6.1.4.1.3052.18.0.1028Notifications350UserTrap1028currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1028.
1.3.6.1.4.1.3052.18.0.1029Notifications350UserTrap1029currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1029.
1.3.6.1.4.1.3052.18.0.1030Notifications350UserTrap1030currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1030.
1.3.6.1.4.1.3052.18.0.1031Notifications350UserTrap1031currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1031.
1.3.6.1.4.1.3052.18.0.1032Notifications350UserTrap1032currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1032.
1.3.6.1.4.1.3052.18.0.1033Notifications350UserTrap1033currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1033.
1.3.6.1.4.1.3052.18.0.1034Notifications350UserTrap1034currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1034.
1.3.6.1.4.1.3052.18.0.1035Notifications350UserTrap1035currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1035.
1.3.6.1.4.1.3052.18.0.1036Notifications350UserTrap1036currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1036.
1.3.6.1.4.1.3052.18.0.1037Notifications350UserTrap1037currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1037.
1.3.6.1.4.1.3052.18.0.1038Notifications350UserTrap1038currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1038.
1.3.6.1.4.1.3052.18.0.1039Notifications350UserTrap1039currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1039.
1.3.6.1.4.1.3052.18.0.1040Notifications350UserTrap1040currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1040.
1.3.6.1.4.1.3052.18.0.1041Notifications350UserTrap1041currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1041.
1.3.6.1.4.1.3052.18.0.1042Notifications350UserTrap1042currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1042.
1.3.6.1.4.1.3052.18.0.1043Notifications350UserTrap1043currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1043.
1.3.6.1.4.1.3052.18.0.1044Notifications350UserTrap1044currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1044.
1.3.6.1.4.1.3052.18.0.1045Notifications350UserTrap1045currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1045.
1.3.6.1.4.1.3052.18.0.1046Notifications350UserTrap1046currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1046.
1.3.6.1.4.1.3052.18.0.1047Notifications350UserTrap1047currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1047.
1.3.6.1.4.1.3052.18.0.1048Notifications350UserTrap1048currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1048.
1.3.6.1.4.1.3052.18.0.1049Notifications350UserTrap1049currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1049.
1.3.6.1.4.1.3052.18.0.1050Notifications350UserTrap1050currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1050.
1.3.6.1.4.1.3052.18.0.1051Notifications350UserTrap1051currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1051.
1.3.6.1.4.1.3052.18.0.1052Notifications350UserTrap1052currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1052.
1.3.6.1.4.1.3052.18.0.1053Notifications350UserTrap1053currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1053.
1.3.6.1.4.1.3052.18.0.1054Notifications350UserTrap1054currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1054.
1.3.6.1.4.1.3052.18.0.1055Notifications350UserTrap1055currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1055.
1.3.6.1.4.1.3052.18.0.1056Notifications350UserTrap1056currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1056.
1.3.6.1.4.1.3052.18.0.1057Notifications350UserTrap1057currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1057.
1.3.6.1.4.1.3052.18.0.1058Notifications350UserTrap1058currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1058.
1.3.6.1.4.1.3052.18.0.1059Notifications350UserTrap1059currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1059.
1.3.6.1.4.1.3052.18.0.1060Notifications350UserTrap1060currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1060.
1.3.6.1.4.1.3052.18.0.1061Notifications350UserTrap1061currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1061.
1.3.6.1.4.1.3052.18.0.1062Notifications350UserTrap1062currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1062.
1.3.6.1.4.1.3052.18.0.1063Notifications350UserTrap1063currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1063.
1.3.6.1.4.1.3052.18.0.1064Notifications350UserTrap1064currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1064.
1.3.6.1.4.1.3052.18.0.1065Notifications350UserTrap1065currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1065.
1.3.6.1.4.1.3052.18.0.1066Notifications350UserTrap1066currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1066.
1.3.6.1.4.1.3052.18.0.1067Notifications350UserTrap1067currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1067.
1.3.6.1.4.1.3052.18.0.1068Notifications350UserTrap1068currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1068.
1.3.6.1.4.1.3052.18.0.1069Notifications350UserTrap1069currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1069.
1.3.6.1.4.1.3052.18.0.1070Notifications350UserTrap1070currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1070.
1.3.6.1.4.1.3052.18.0.1071Notifications350UserTrap1071currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1071.
1.3.6.1.4.1.3052.18.0.1072Notifications350UserTrap1072currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1072.
1.3.6.1.4.1.3052.18.0.1073Notifications350UserTrap1073currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1073.
1.3.6.1.4.1.3052.18.0.1074Notifications350UserTrap1074currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1074.
1.3.6.1.4.1.3052.18.0.1075Notifications350UserTrap1075currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1075.
1.3.6.1.4.1.3052.18.0.1076Notifications350UserTrap1076currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1076.
1.3.6.1.4.1.3052.18.0.1077Notifications350UserTrap1077currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1077.
1.3.6.1.4.1.3052.18.0.1078Notifications350UserTrap1078currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1078.
1.3.6.1.4.1.3052.18.0.1079Notifications350UserTrap1079currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1079.
1.3.6.1.4.1.3052.18.0.1080Notifications350UserTrap1080currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1080.
1.3.6.1.4.1.3052.18.0.1081Notifications350UserTrap1081currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1081.
1.3.6.1.4.1.3052.18.0.1082Notifications350UserTrap1082currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1082.
1.3.6.1.4.1.3052.18.0.1083Notifications350UserTrap1083currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1083.
1.3.6.1.4.1.3052.18.0.1084Notifications350UserTrap1084currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1084.
1.3.6.1.4.1.3052.18.0.1085Notifications350UserTrap1085currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1085.
1.3.6.1.4.1.3052.18.0.1086Notifications350UserTrap1086currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1086.
1.3.6.1.4.1.3052.18.0.1087Notifications350UserTrap1087currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1087.
1.3.6.1.4.1.3052.18.0.1088Notifications350UserTrap1088currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1088.
1.3.6.1.4.1.3052.18.0.1089Notifications350UserTrap1089currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1089.
1.3.6.1.4.1.3052.18.0.1090Notifications350UserTrap1090currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1090.
1.3.6.1.4.1.3052.18.0.1091Notifications350UserTrap1091currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1091.
1.3.6.1.4.1.3052.18.0.1092Notifications350UserTrap1092currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1092.
1.3.6.1.4.1.3052.18.0.1093Notifications350UserTrap1093currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1093.
1.3.6.1.4.1.3052.18.0.1094Notifications350UserTrap1094currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1094.
1.3.6.1.4.1.3052.18.0.1095Notifications350UserTrap1095currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1095.
1.3.6.1.4.1.3052.18.0.1096Notifications350UserTrap1096currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1096.
1.3.6.1.4.1.3052.18.0.1097Notifications350UserTrap1097currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1097.
1.3.6.1.4.1.3052.18.0.1098Notifications350UserTrap1098currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1098.
1.3.6.1.4.1.3052.18.0.1099Notifications350UserTrap1099currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1099.
1.3.6.1.4.1.3052.18.0.1100Notifications350UserTrap1100currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1100.
1.3.6.1.4.1.3052.18.0.1101Notifications350UserTrap1101currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1101.
1.3.6.1.4.1.3052.18.0.1102Notifications350UserTrap1102currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1102.
1.3.6.1.4.1.3052.18.0.1103Notifications350UserTrap1103currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1103.
1.3.6.1.4.1.3052.18.0.1104Notifications350UserTrap1104currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1104.
1.3.6.1.4.1.3052.18.0.1105Notifications350UserTrap1105currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1105.
1.3.6.1.4.1.3052.18.0.1106Notifications350UserTrap1106currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1106.
1.3.6.1.4.1.3052.18.0.1107Notifications350UserTrap1107currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1107.
1.3.6.1.4.1.3052.18.0.1108Notifications350UserTrap1108currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1108.
1.3.6.1.4.1.3052.18.0.1109Notifications350UserTrap1109currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1109.
1.3.6.1.4.1.3052.18.0.1110Notifications350UserTrap1110currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1110.
1.3.6.1.4.1.3052.18.0.1111Notifications350UserTrap1111currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1111.
1.3.6.1.4.1.3052.18.0.1112Notifications350UserTrap1112currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1112.
1.3.6.1.4.1.3052.18.0.1113Notifications350UserTrap1113currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1113.
1.3.6.1.4.1.3052.18.0.1114Notifications350UserTrap1114currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1114.
1.3.6.1.4.1.3052.18.0.1115Notifications350UserTrap1115currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1115.
1.3.6.1.4.1.3052.18.0.1116Notifications350UserTrap1116currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1116.
1.3.6.1.4.1.3052.18.0.1117Notifications350UserTrap1117currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1117.
1.3.6.1.4.1.3052.18.0.1118Notifications350UserTrap1118currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1118.
1.3.6.1.4.1.3052.18.0.1119Notifications350UserTrap1119currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1119.
1.3.6.1.4.1.3052.18.0.1120Notifications350UserTrap1120currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1120.
1.3.6.1.4.1.3052.18.0.1121Notifications350UserTrap1121currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1121.
1.3.6.1.4.1.3052.18.0.1122Notifications350UserTrap1122currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1122.
1.3.6.1.4.1.3052.18.0.1123Notifications350UserTrap1123currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1123.
1.3.6.1.4.1.3052.18.0.1124Notifications350UserTrap1124currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1124.
1.3.6.1.4.1.3052.18.0.1125Notifications350UserTrap1125currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1125.
1.3.6.1.4.1.3052.18.0.1126Notifications350UserTrap1126currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1126.
1.3.6.1.4.1.3052.18.0.1127Notifications350UserTrap1127currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1127.
1.3.6.1.4.1.3052.18.0.1128Notifications350UserTrap1128currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1128.
1.3.6.1.4.1.3052.18.0.1129Notifications350UserTrap1129currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1129.
1.3.6.1.4.1.3052.18.0.1130Notifications350UserTrap1130currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1130.
1.3.6.1.4.1.3052.18.0.1131Notifications350UserTrap1131currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1131.
1.3.6.1.4.1.3052.18.0.1132Notifications350UserTrap1132currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1132.
1.3.6.1.4.1.3052.18.0.1133Notifications350UserTrap1133currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1133.
1.3.6.1.4.1.3052.18.0.1134Notifications350UserTrap1134currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1134.
1.3.6.1.4.1.3052.18.0.1135Notifications350UserTrap1135currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1135.
1.3.6.1.4.1.3052.18.0.1136Notifications350UserTrap1136currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1136.
1.3.6.1.4.1.3052.18.0.1137Notifications350UserTrap1137currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1137.
1.3.6.1.4.1.3052.18.0.1138Notifications350UserTrap1138currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1138.
1.3.6.1.4.1.3052.18.0.1139Notifications350UserTrap1139currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1139.
1.3.6.1.4.1.3052.18.0.1140Notifications350UserTrap1140currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1140.
1.3.6.1.4.1.3052.18.0.1141Notifications350UserTrap1141currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1141.
1.3.6.1.4.1.3052.18.0.1142Notifications350UserTrap1142currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1142.
1.3.6.1.4.1.3052.18.0.1143Notifications350UserTrap1143currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1143.
1.3.6.1.4.1.3052.18.0.1144Notifications350UserTrap1144currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1144.
1.3.6.1.4.1.3052.18.0.1145Notifications350UserTrap1145currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1145.
1.3.6.1.4.1.3052.18.0.1146Notifications350UserTrap1146currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1146.
1.3.6.1.4.1.3052.18.0.1147Notifications350UserTrap1147currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1147.
1.3.6.1.4.1.3052.18.0.1148Notifications350UserTrap1148currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1148.
1.3.6.1.4.1.3052.18.0.1149Notifications350UserTrap1149currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1149.
1.3.6.1.4.1.3052.18.0.1150Notifications350UserTrap1150currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1150.
1.3.6.1.4.1.3052.18.0.1151Notifications350UserTrap1151currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1151.
1.3.6.1.4.1.3052.18.0.1152Notifications350UserTrap1152currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1152.
1.3.6.1.4.1.3052.18.0.1153Notifications350UserTrap1153currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1153.
1.3.6.1.4.1.3052.18.0.1154Notifications350UserTrap1154currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1154.
1.3.6.1.4.1.3052.18.0.1155Notifications350UserTrap1155currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1155.
1.3.6.1.4.1.3052.18.0.1156Notifications350UserTrap1156currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1156.
1.3.6.1.4.1.3052.18.0.1157Notifications350UserTrap1157currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1157.
1.3.6.1.4.1.3052.18.0.1158Notifications350UserTrap1158currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1158.
1.3.6.1.4.1.3052.18.0.1159Notifications350UserTrap1159currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1159.
1.3.6.1.4.1.3052.18.0.1160Notifications350UserTrap1160currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1160.
1.3.6.1.4.1.3052.18.0.1161Notifications350UserTrap1161currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1161.
1.3.6.1.4.1.3052.18.0.1162Notifications350UserTrap1162currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1162.
1.3.6.1.4.1.3052.18.0.1163Notifications350UserTrap1163currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1163.
1.3.6.1.4.1.3052.18.0.1164Notifications350UserTrap1164currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1164.
1.3.6.1.4.1.3052.18.0.1165Notifications350UserTrap1165currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1165.
1.3.6.1.4.1.3052.18.0.1166Notifications350UserTrap1166currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1166.
1.3.6.1.4.1.3052.18.0.1167Notifications350UserTrap1167currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1167.
1.3.6.1.4.1.3052.18.0.1168Notifications350UserTrap1168currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1168.
1.3.6.1.4.1.3052.18.0.1169Notifications350UserTrap1169currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1169.
1.3.6.1.4.1.3052.18.0.1170Notifications350UserTrap1170currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1170.
1.3.6.1.4.1.3052.18.0.1171Notifications350UserTrap1171currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1171.
1.3.6.1.4.1.3052.18.0.1172Notifications350UserTrap1172currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1172.
1.3.6.1.4.1.3052.18.0.1173Notifications350UserTrap1173currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1173.
1.3.6.1.4.1.3052.18.0.1174Notifications350UserTrap1174currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1174.
1.3.6.1.4.1.3052.18.0.1175Notifications350UserTrap1175currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1175.
1.3.6.1.4.1.3052.18.0.1176Notifications350UserTrap1176currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1176.
1.3.6.1.4.1.3052.18.0.1177Notifications350UserTrap1177currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1177.
1.3.6.1.4.1.3052.18.0.1178Notifications350UserTrap1178currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1178.
1.3.6.1.4.1.3052.18.0.1179Notifications350UserTrap1179currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1179.
1.3.6.1.4.1.3052.18.0.1180Notifications350UserTrap1180currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1180.
1.3.6.1.4.1.3052.18.0.1181Notifications350UserTrap1181currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1181.
1.3.6.1.4.1.3052.18.0.1182Notifications350UserTrap1182currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1182.
1.3.6.1.4.1.3052.18.0.1183Notifications350UserTrap1183currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1183.
1.3.6.1.4.1.3052.18.0.1184Notifications350UserTrap1184currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1184.
1.3.6.1.4.1.3052.18.0.1185Notifications350UserTrap1185currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1185.
1.3.6.1.4.1.3052.18.0.1186Notifications350UserTrap1186currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1186.
1.3.6.1.4.1.3052.18.0.1187Notifications350UserTrap1187currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1187.
1.3.6.1.4.1.3052.18.0.1188Notifications350UserTrap1188currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1188.
1.3.6.1.4.1.3052.18.0.1189Notifications350UserTrap1189currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1189.
1.3.6.1.4.1.3052.18.0.1190Notifications350UserTrap1190currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1190.
1.3.6.1.4.1.3052.18.0.1191Notifications350UserTrap1191currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1191.
1.3.6.1.4.1.3052.18.0.1192Notifications350UserTrap1192currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1192.
1.3.6.1.4.1.3052.18.0.1193Notifications350UserTrap1193currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1193.
1.3.6.1.4.1.3052.18.0.1194Notifications350UserTrap1194currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1194.
1.3.6.1.4.1.3052.18.0.1195Notifications350UserTrap1195currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1195.
1.3.6.1.4.1.3052.18.0.1196Notifications350UserTrap1196currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1196.
1.3.6.1.4.1.3052.18.0.1197Notifications350UserTrap1197currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1197.
1.3.6.1.4.1.3052.18.0.1198Notifications350UserTrap1198currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1198.
1.3.6.1.4.1.3052.18.0.1199Notifications350UserTrap1199currentThis user-defined trap is issued when an event happens that causes a trap with specific trap type 1199.
1.3.6.1.4.1.3052.18.1Nodestatus
1.3.6.1.4.1.3052.18.1.1NodeeventSensorStatus
1.3.6.1.4.1.3052.18.1.1.1TableesPointTablenot-accessiblecurrentThis table organizes 4 basic attributes of points. A point is a particular sensor on an EventSensor (e.g., temperature, humidity, contact closure 2, output 5, …
1.3.6.1.4.1.3052.18.1.1.1.1RowesPointEntrynot-accessiblecurrentEntry for EventSensor point table
1.3.6.1.4.1.3052.18.1.1.1.1.1ColumnesIndexESread-onlycurrentThe part of the point index that refers to an EventSensor. The point index is a string of 3 numbers separated by periods. It contains all the information neces…
1.3.6.1.4.1.3052.18.1.1.1.1.2ColumnesIndexPCread-onlycurrentThe part of the point index that refers to point class. The point index is a string of 3 numbers separated by periods. It contains all the information necessar…
1.3.6.1.4.1.3052.18.1.1.1.1.3ColumnesIndexPointread-onlycurrentThe part of the point index that delineates which sensor on the EventSensor. So this combined with esIndexPC (Point Class or type) and esIndexES (which EventSe…
1.3.6.1.4.1.3052.18.1.1.1.1.4ColumnesPointNameread-writecurrentThe name of the point on an EventSensor. For example, 'AC temp' (in the case of the temperature sensor on an EventSensor). There can be multiple points of the …
1.3.6.1.4.1.3052.18.1.1.1.1.5ColumnesPointInEventStateread-writecurrentA number referring to the event state of a point on an EventSensor. This number can have different meanings depending on the point class. If the point class is…
1.3.6.1.4.1.3052.18.1.1.1.1.6ColumnesPointValueIntread-writecurrentA read-only number referring to the value of a point on an EventSensor. If the point class is temperature, then this object is the temperature in its configure…
1.3.6.1.4.1.3052.18.1.1.1.1.7ColumnesPointValueStrread-onlycurrentA string referring to the value of a point on an EventSensor. For contact closures this object is either 'Open' or 'Closed'. For outputs this object is a conca…
1.3.6.1.4.1.3052.18.1.1.1.1.8ColumnesPointTimeLastChangeread-onlycurrentThe time of the last time an event was triggerred for a point on an EventSensor in MM/DD/YY HH:MM:SS format. For contact closures, the possible events are Acti…
1.3.6.1.4.1.3052.18.1.1.1.1.9ColumnesPointTimetickLastChangeread-onlycurrentThe time of the last time an event was triggerred for a point on an EventSensor in 100ths of seconds since reset. For contact closures, the possible events are…
1.3.6.1.4.1.3052.18.1.1.1.1.10ColumnesPointAliasValueStrread-onlycurrentFor CC inputs, this is the CC active/inactive alias setting setting value that currently corresponds to the event state. So if the CC input is in the event sta…
1.3.6.1.4.1.3052.18.1.2NodedataEventStatus
1.3.6.1.4.1.3052.18.1.2.1TabledeStatusTablenot-accessiblecurrentData Event Status Table
1.3.6.1.4.1.3052.18.1.2.1.1RowdeStatusEntrynot-accessiblecurrentEventSensor status entry
1.3.6.1.4.1.3052.18.1.2.1.1.1ColumndeStatusIndexread-onlycurrentIndex for Data Events
1.3.6.1.4.1.3052.18.1.2.1.1.2ColumndeStatusNameread-onlycurrentData Event name
1.3.6.1.4.1.3052.18.1.2.1.1.3ColumndeStatusCounterread-onlycurrentNumber of times a data record has matched this event's equation. Range: 1-999999999
1.3.6.1.4.1.3052.18.1.2.1.1.4ColumndeStatusThresholdread-onlycurrentNumber of times the equation is matched before an event is triggered. Range: 1-999999999
1.3.6.1.4.1.3052.18.1.5NodepowerDistributionStatus
1.3.6.1.4.1.3052.18.1.5.1ScalarpdConfigread-onlycurrentPower Distribution output configuration
1.3.6.1.4.1.3052.18.1.5.4NodepdNextGen
1.3.6.1.4.1.3052.18.1.5.4.1TablepdnTablenot-accessiblecurrentTable of power distribution objects arranged according to next-generation methodology (i.e., using multiple PowerBoss power distributors in addition to the on-…
1.3.6.1.4.1.3052.18.1.5.4.1.1RowpdnEntrynot-accessiblecurrentEntry for table of power distribution objects arranged according to next-generation methodology (i.e., using multiple PowerBoss power distributors in addition …
1.3.6.1.4.1.3052.18.1.5.4.1.1.1ColumnpdnIndexPDread-onlycurrentIndex for table of power distribution objects, specifically the index that refers to which power distributor. A value of 200 means the internal power distribut…
1.3.6.1.4.1.3052.18.1.5.4.1.1.2ColumnpdnIndexOutputread-onlycurrentIndex for table of power distribution objects, specifically the index that refers to which output on the power distributor specified by pdnIndexPD. For objects…
1.3.6.1.4.1.3052.18.1.5.4.1.1.3ColumnpdnConfigread-onlycurrentThe number of outputs on the power distributor specified by pdnIndexPD. pdnIndexOutput should be 1 for this object.
1.3.6.1.4.1.3052.18.1.5.4.1.1.4ColumnpdnMainCurrentInEventStateread-onlycurrentThe event state of the current (i.e. Amps) event of the power distributor specified by pdnIndexPD. pdnIndexOutput should be 1 for this object. Possible values …
1.3.6.1.4.1.3052.18.1.5.4.1.1.5ColumnpdnMainCurrentValueread-onlycurrentThe current drawn, in mA, for the power distributor specified by pdnIndexPD. If pdnIndexPD is 1-16 then this is an external power distributor (PowerBoss) and r…
1.3.6.1.4.1.3052.18.1.5.4.1.1.6ColumnpdnMainCurrentValueStrread-onlycurrentEssentially pdnMainCurrentValue formatted as a string in units of Amps, with 3 decimal places. pdnIndexOutput should be 1 for this object.
1.3.6.1.4.1.3052.18.1.5.4.1.1.7ColumnpdnMainCurrentDeadbandread-onlycurrentThe deadband, in mA, for the main current sensor for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this object.
1.3.6.1.4.1.3052.18.1.5.4.1.1.8ColumnpdnMainCurrentVHighCurrentread-onlycurrentThe current, in mA, for the main current sensor's Very High event threshold, for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for t…
1.3.6.1.4.1.3052.18.1.5.4.1.1.9ColumnpdnMainCurrentHighCurrentread-onlycurrentThe current, in mA, for the main current sensor's High event threshold, for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this o…
1.3.6.1.4.1.3052.18.1.5.4.1.1.10ColumnpdnMainCurrentLowCurrentread-onlycurrentThe current, in mA, for the main current sensor's Low event threshold, for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this ob…
1.3.6.1.4.1.3052.18.1.5.4.1.1.11ColumnpdnMainCurrentVLowCurrentread-onlycurrentThe current, in mA, for the main current sensor's Very Low event threshold, for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for th…
1.3.6.1.4.1.3052.18.1.5.4.1.1.12ColumnpdnMainVoltageInEventStateread-onlycurrentThe event state of the voltage event of the power distributor specified by pdnIndexPD. pdnIndexOutput should be 1 for this object. Possible values for this obj…
1.3.6.1.4.1.3052.18.1.5.4.1.1.13ColumnpdnMainVoltageValueread-onlycurrentThe voltage, in mV, at the power distributor specified by pdnIndexPD. If pdnIndexPD is 1-16 then this is an external power distributor (PowerBoss) and refers t…
1.3.6.1.4.1.3052.18.1.5.4.1.1.14ColumnpdnMainVoltageValueStrread-onlycurrentEssentially pdnMainVoltageValue formatted as a string in units of Volts, with 3 decimal places. pdnIndexOutput should be 1 for this object.
1.3.6.1.4.1.3052.18.1.5.4.1.1.15ColumnpdnMainVoltageDeadbandread-onlycurrentThe deadband, in mV, for the main voltage sensor for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this object.
1.3.6.1.4.1.3052.18.1.5.4.1.1.16ColumnpdnMainVoltageVHighVoltageread-onlycurrentThe voltage, in mA, for the main voltage sensor's Very High event threshold, for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for t…
1.3.6.1.4.1.3052.18.1.5.4.1.1.17ColumnpdnMainVoltageHighVoltageread-onlycurrentThe voltage, in mV, for the main voltage sensor's High event threshold, for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this o…
1.3.6.1.4.1.3052.18.1.5.4.1.1.18ColumnpdnMainVoltageLowVoltageread-onlycurrentThe voltage, in mV, for the main voltage sensor's Low event threshold, for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this ob…
1.3.6.1.4.1.3052.18.1.5.4.1.1.19ColumnpdnMainVoltageVLowVoltageread-onlycurrentThe voltage, in mV, for the main voltage sensor's Very Low event threshold, for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for th…
1.3.6.1.4.1.3052.18.1.5.4.1.1.20ColumnpdnMainPowerValueread-onlycurrentThe power, in Watts, for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this object.
1.3.6.1.4.1.3052.18.1.5.4.1.1.21ColumnpdnMainPowerValueStrread-onlycurrentThe power, in Watts, for the power distributor specified by pdIndexPD, formatted as a string with the unit name 'Watts'. pdnIndexOutput should be 1 for this ob…
1.3.6.1.4.1.3052.18.1.5.4.1.1.22ColumnpdnOutputCurrentInEventStateread-onlycurrentThe event state of the current (i.e. Amps) event of the power distributor output specified by pdnIndexPD and pdnIndexOutput. E.g., for pdnIndexPD=200 and pdnIn…
1.3.6.1.4.1.3052.18.1.5.4.1.1.23ColumnpdnOutputCurrentValueread-onlycurrentThe current drawn, in mA, for the power distributor output specified by pdnIndexPD and pdIndexOutput. E.g., if pdIndexPD is 3 then this is an external power di…
1.3.6.1.4.1.3052.18.1.5.4.1.1.24ColumnpdnOutputCurrentValueStrread-onlycurrentEssentially pdnOutputCurrentValue formatted as a string in units of Amps, with 3 decimal places.
1.3.6.1.4.1.3052.18.1.5.4.1.1.25ColumnpdnOutputCurrentDeadbandread-onlycurrentThe deadband, in mA, for the main current sensor for the power distributor specified by pdIndexPD. The power output is specified by pdnIndexOutput.
1.3.6.1.4.1.3052.18.1.5.4.1.1.26ColumnpdnOutputCurrentVHighCurrentread-onlycurrentThe current, in mA, for a specific power output's current sensor Very High event threshold, for the power distributor specified by pdIndexPD. The power output …
1.3.6.1.4.1.3052.18.1.5.4.1.1.27ColumnpdnOutputCurrentHighCurrentread-onlycurrentThe current, in mA, for a specific power output's current sensor High event threshold, for the power distributor specified by pdIndexPD. The power output is sp…
1.3.6.1.4.1.3052.18.1.5.4.1.1.28ColumnpdnOutputCurrentLowCurrentread-onlycurrentThe current, in mA, for a specific power output's current sensor Low event threshold, for the power distributor specified by pdIndexPD. The power output is spe…
1.3.6.1.4.1.3052.18.1.5.4.1.1.29ColumnpdnOutputCurrentVLowCurrentread-onlycurrentThe current, in mA, for a specific power output's current sensor Very Low event threshold, for the power distributor specified by pdIndexPD. The power output i…
1.3.6.1.4.1.3052.18.1.5.4.1.1.30ColumnpdnOutputFuseInEventStateread-onlycurrentThe event state of the fuse event of the power distributor output specified by pdnIndexPD and pdnIndexOutput. E.g., for pdnIndexPD=14 and pdnIndexOutput=2, thi…
1.3.6.1.4.1.3052.18.1.5.4.1.1.31ColumnpdnOutputFuseValueStrread-onlycurrentThe state of the fuse of the power distributor output specified by pdnIndexPD and pdnIndexOutput. Possible values for this object are: 'BLOWN' and 'OK'. This o…
1.3.6.1.4.1.3052.18.1.5.4.1.1.32ColumnpdnMainCombinedStatusread-onlycurrentCombined status string intended to be parsed by NMS: format: voltageColorCode`voltageEventState`voltageValue`mainCurrentColorCode`mainCurrentEventState`mainCur…
1.3.6.1.4.1.3052.18.1.5.4.1.1.33ColumnpdnOutputCombinedStatusBlock1read-onlycurrentCombined status string intended to be parsed by NMS: format: numInBlock~outputCurrentColorCode1`outputCurrentEventState1`outputCurrentValue1`fuseColorCode1`fus…
1.3.6.1.4.1.3052.18.1.5.4.1.1.34ColumnpdnOutputCombinedStatusBlock2read-onlycurrentCombined status string intended to be parsed by NMS: format: numInBlock~outputCurrentColorCode1`outputCurrentEventState1`outputCurrentValue1`fuseColorCode1`fus…
1.3.6.1.4.1.3052.18.1.5.4.1.1.35ColumnpdnDeviceCurrentValueread-onlycurrentCurrent drawn by device in mA. For the internal power distributor device, this is the current drawn by the SiteBoss 571. For an external power distributor devi…
1.3.6.1.4.1.3052.18.1.5.4.1.1.36ColumnpdnDeviceCurrentValueStrread-onlycurrentCurrent drawn by device as a string with units (Amps). For the internal power distributor device, this is the current drawn by the SiteBoss 571. For an externa…
1.3.6.1.4.1.3052.18.1.5.5NodepdSystem
1.3.6.1.4.1.3052.18.1.5.5.1ScalarpdSystemCurrentread-onlycurrentTotal current drawn by all power distributors in system; that is, the sum of all pdnMainCurrentValue objects for all connected power distributors: internal and…
1.3.6.1.4.1.3052.18.1.5.5.2ScalarpdSystemPowerread-onlycurrentTotal power used by all power distributors in system; that is, the sum of all pdnMainPowerValue objects for all connected power distributors: internal and exte…
1.3.6.1.4.1.3052.18.1.6NodefuelSensorStatus
1.3.6.1.4.1.3052.18.1.6.1TablefsStatusTablenot-accessiblecurrentFuel sensor status table
1.3.6.1.4.1.3052.18.1.6.1.1RowfsStatusEntrynot-accessiblecurrentFuel sensor status table entry
1.3.6.1.4.1.3052.18.1.6.1.1.1ColumnfsStatusIndexread-onlycurrentIndex for fuel sensors
1.3.6.1.4.1.3052.18.1.6.1.1.2ColumnfsStatusNameread-onlycurrentFuel sensor name
1.3.6.1.4.1.3052.18.1.6.1.1.3ColumnfsStatusDeviceStateread-onlycurrentFuel sensor device state
1.3.6.1.4.1.3052.18.1.6.1.1.4ColumnfsStatusVolumeValueStringread-onlycurrentFuel volume. Range is -2,147,483,648 to 2,147,483,647. This value reads -999 when the fuel sensor is disconnected
1.3.6.1.4.1.3052.18.1.6.1.1.7ColumnfsStatusVolumePercentLevelread-onlycurrentHeight of the fluid in the tank expressed as a percentage of the tank height, in hundredths of a percent.
1.3.6.1.4.1.3052.18.1.6.1.1.8ColumnfsStatusVolumeInEventStateread-onlycurrentCurrent event status of the fuel sensor.
1.3.6.1.4.1.3052.18.1.6.1.1.9ColumnfsStatusCombinedread-onlycurrentCombined status string intended to be parsed by NMS: deviceState`deviceStateColorCode`percentRounded`valueAsFloat`volumeEventState`volumeEventStateColorCode`ca…
1.3.6.1.4.1.3052.18.1.7NodewirelessModemStatus
1.3.6.1.4.1.3052.18.1.7.1ScalarwmsStatusread-onlycurrentWireless modem status
1.3.6.1.4.1.3052.18.1.7.2ScalarwmsSignalread-onlycurrentWireless modem Signal strength
1.3.6.1.4.1.3052.18.1.7.3ScalarwmsRSSIread-onlycurrentWireless modem Signal strength (RSSI)
1.3.6.1.4.1.3052.18.1.7.4ScalarwmsBERread-onlycurrentWireless modem Bit Error Rate
1.3.6.1.4.1.3052.18.1.7.5ScalarwmsUpdatedread-onlycurrentWireless modem info last update time
1.3.6.1.4.1.3052.18.1.7.6ScalarwmsRegistrationread-onlycurrentWireless modem registration status
1.3.6.1.4.1.3052.18.1.7.7ScalarwmsLACread-onlycurrentWireless modem Location Area Code
1.3.6.1.4.1.3052.18.1.7.8ScalarwmsCellIDread-onlycurrentWireless modem Cell ID
1.3.6.1.4.1.3052.18.1.7.9ScalarwmsIMSIread-onlycurrentWireless modem Internation Mobile Subscriber Identity number
1.3.6.1.4.1.3052.18.1.7.10ScalarwmsPhnumread-onlycurrentWireless modem phone number
1.3.6.1.4.1.3052.18.1.7.11ScalarwmsLocalIPread-onlycurrentLocal IP address of modem on wireless network
1.3.6.1.4.1.3052.18.1.7.12ScalarwmsMgfIDread-onlycurrentWireless modem manufacturer ID
1.3.6.1.4.1.3052.18.1.7.13ScalarwmsModelIDread-onlycurrentWireless modem model ID
1.3.6.1.4.1.3052.18.1.7.14ScalarwmsIMEIread-onlycurrentWireless modem International Mobile Equipment Identity number
1.3.6.1.4.1.3052.18.1.7.15ScalarwmsRevIDread-onlycurrentWireless modem revision ID
1.3.6.1.4.1.3052.18.1.7.16ScalarwmsNetNameread-onlycurrentWireless modem network name
1.3.6.1.4.1.3052.18.1.7.17ScalarwmsGPRSStatusread-onlycurrentWireless modem (E)GPRS status
1.3.6.1.4.1.3052.18.1.7.18ScalarwmsBandread-onlycurrentWireless modem band
1.3.6.1.4.1.3052.18.1.7.19ScalarwmsChannelread-onlycurrentWireless modem channel
1.3.6.1.4.1.3052.18.1.7.20ScalarwmsCountryCoderead-onlycurrentWireless modem country code
1.3.6.1.4.1.3052.18.1.7.21ScalarwmsNetCoderead-onlycurrentWireless modem network code
1.3.6.1.4.1.3052.18.1.7.22ScalarwmsPLMNColorread-onlycurrentWireless modem PLMN color
1.3.6.1.4.1.3052.18.1.7.23ScalarwmsBScolorread-onlycurrentWireless modem BS color
1.3.6.1.4.1.3052.18.1.7.24ScalarwmsMpRACHread-onlycurrentWireless modem max power RACH
1.3.6.1.4.1.3052.18.1.7.25ScalarwmsMinRxLevelread-onlycurrentWireless modem minimum receive level
1.3.6.1.4.1.3052.18.1.7.26ScalarwmsBaseCoeffread-onlycurrentWireless modem base coefficient
1.3.6.1.4.1.3052.18.1.7.27ScalarwmsSIMStatusread-onlycurrentWWireless modem SIM status
1.3.6.1.4.1.3052.18.1.7.28ScalarwmsICCIDread-onlycurrentWireless modem SIM ICCID
1.3.6.1.4.1.3052.18.1.7.29ScalarwmsModemTyperead-onlycurrentWireless modem type
1.3.6.1.4.1.3052.18.1.8NodeacPowerMonitorStatus
1.3.6.1.4.1.3052.18.1.8.1TableacpmStatusTablenot-accessiblecurrentAC power monitor status table
1.3.6.1.4.1.3052.18.1.8.1.1RowacpmStatusEntrynot-accessiblecurrentAC power monitor status table entry
1.3.6.1.4.1.3052.18.1.8.1.1.1ColumnacpmsIndexread-onlycurrentIndex for AC power monitors
1.3.6.1.4.1.3052.18.1.8.1.1.2ColumnacpmsNameread-onlycurrentName for the AC power monitor device.
1.3.6.1.4.1.3052.18.1.8.1.1.3ColumnacpmsAvgVoltageValueStrread-onlycurrentAverage voltage, in volts. This is calculated using the formula (register * PT ratio * 0.1). This could be either the average of the phase voltages, or the sum…
1.3.6.1.4.1.3052.18.1.8.1.1.4ColumnacpmsAvgVoltageMinStrread-onlycurrentMinimum average voltage value since last reset, in volts.
1.3.6.1.4.1.3052.18.1.8.1.1.5ColumnacpmsAvgVoltageMaxStrread-onlycurrentMaximum average voltage value since last reset, in volts.
1.3.6.1.4.1.3052.18.1.8.1.1.6ColumnacpmsAvgVoltageAvgStrread-onlycurrentAverage average voltage value since last reset, in volts. This is the unit's average of its measurements of the average voltage reported by the AC power monito…
1.3.6.1.4.1.3052.18.1.8.1.1.7ColumnacpmsAvgVoltageInEventStateread-onlycurrentEvent state of this AC power monitor voltage (Low, Normal, High, etc.).
1.3.6.1.4.1.3052.18.1.8.1.1.8ColumnacpmsVoltagePhaseAValueStrread-onlycurrentPhase A voltage, in volts. This is calculated using the formula (register * PT ratio * 0.1).
1.3.6.1.4.1.3052.18.1.8.1.1.9ColumnacpmsVoltagePhaseBValueStrread-onlycurrentPhase B voltage, in volts. This is calculated using the formula (register * PT ratio * 0.1).
1.3.6.1.4.1.3052.18.1.8.1.1.10ColumnacpmsVoltagePhaseCValueStrread-onlycurrentPhase C voltage, in volts. This is calculated using the formula (register * PT ratio * 0.1).
1.3.6.1.4.1.3052.18.1.8.1.1.11ColumnacpmsAvgCurrentValueStrread-onlycurrentAverage current, in amps. This is calculated using the formula (register * CT ratio * 0.001). This could be either the average of the phase currents, or the su…
1.3.6.1.4.1.3052.18.1.8.1.1.12ColumnacpmsAvgCurrentMinStrread-onlycurrentMinimum average current value since last reset, in amps.
1.3.6.1.4.1.3052.18.1.8.1.1.13ColumnacpmsAvgCurrentMaxStrread-onlycurrentMaximum average current value since last reset, in amps.
1.3.6.1.4.1.3052.18.1.8.1.1.14ColumnacpmsAvgCurrentAvgStrread-onlycurrentAverage average current value since last reset, in amps. This is the unit's average of its measurements of the average current reported by the AC power monitor…
1.3.6.1.4.1.3052.18.1.8.1.1.15ColumnacpmsAvgCurrentInEventStateread-onlycurrentEvent state of this AC power monitor current (Low, Normal, High, etc.).
1.3.6.1.4.1.3052.18.1.8.1.1.16ColumnacpmsCurrentPhaseAValueStrread-onlycurrentPhase A current, in amps. This is calculated using the formula (register * CT ratio * 0.001).
1.3.6.1.4.1.3052.18.1.8.1.1.17ColumnacpmsCurrentPhaseBValueStrread-onlycurrentPhase B current, in amps. This is calculated using the formula (register * CT ratio * 0.001).
1.3.6.1.4.1.3052.18.1.8.1.1.18ColumnacpmsCurrentPhaseCValueStrread-onlycurrentPhase C current, in amps. This is calculated using the formula (register * CT ratio * 0.001).
1.3.6.1.4.1.3052.18.1.8.1.1.19ColumnacpmsAvgFreqValueStrread-onlycurrentFrequency, in hertz. On the YD2010, this is calculated using the formula (register * 0.00106813). On the WattsOn, this is calculated using the formula (registe…
1.3.6.1.4.1.3052.18.1.8.1.1.20ColumnacpmsAvgFreqMinStrread-onlycurrentMinimum frequency value since last reset, in hertz.
1.3.6.1.4.1.3052.18.1.8.1.1.21ColumnacpmsAvgFreqMaxStrread-onlycurrentMaximum frequency value since last reset, in hertz.
1.3.6.1.4.1.3052.18.1.8.1.1.22ColumnacpmsAvgFreqAvgStrread-onlycurrentAverage frequency value since last reset, in hertz. This is the unit's average of its measurements of the average frequency reported by the AC power monitor de…
1.3.6.1.4.1.3052.18.1.8.1.1.23ColumnacpmsAvgFreqInEventStateread-onlycurrentEvent state of this AC power monitor frequency (Low, Normal, High, etc.).
1.3.6.1.4.1.3052.18.1.8.1.1.24ColumnacpmsTRPValueStrread-onlycurrentTotal real power, in watts. On the YD2010, this is calculated using the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is the voltage range ta…
1.3.6.1.4.1.3052.18.1.8.1.1.25ColumnacpmsTRPMinStrread-onlycurrentMinimum total real power value since last reset, in watts.
1.3.6.1.4.1.3052.18.1.8.1.1.26ColumnacpmsTRPMaxStrread-onlycurrentMaximum total real power value since last reset, in watts.
1.3.6.1.4.1.3052.18.1.8.1.1.27ColumnacpmsTRPAvgStrread-onlycurrentAverage total real power value since last reset, in watts. This is the unit's average of its measurements of the average total real power reported by the AC po…
1.3.6.1.4.1.3052.18.1.8.1.1.28ColumnacpmsTRPInEventStateread-onlycurrentEvent state of this AC power monitor total real power (Low, Normal, High, etc.).
1.3.6.1.4.1.3052.18.1.8.1.1.29ColumnacpmsRPPhaseAValueStrread-onlycurrentPhase A real power, in watts. On the YD2010, this is calculated using the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is the voltage range …
1.3.6.1.4.1.3052.18.1.8.1.1.30ColumnacpmsRPPhaseBValueStrread-onlycurrentPhase B real power, in watts. On the YD2010, this is calculated using the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is the voltage range …
1.3.6.1.4.1.3052.18.1.8.1.1.31ColumnacpmsRPPhaseCValueStrread-onlycurrentPhase C real power, in watts. On the YD2010, this is calculated using the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is the voltage range …
1.3.6.1.4.1.3052.18.1.8.1.1.32ColumnacpmsCombinedread-onlycurrentCombined status string intended to be parsed by NMS: name`deviceState`deviceStateColorCode`voltage`current`frequency`power~voltageEventState`voltageColorCode`c…
1.3.6.1.4.1.3052.18.1.8.1.1.33ColumnacpmsTPFValueStrread-onlycurrentTotal power factor.
1.3.6.1.4.1.3052.18.1.8.1.1.34ColumnacpmsTPFMinStrread-onlycurrentTotal power factor minimum value since last reset.
1.3.6.1.4.1.3052.18.1.8.1.1.35ColumnacpmsTPFMaxStrread-onlycurrentTotal power factor maximum value since last reset.
1.3.6.1.4.1.3052.18.1.8.1.1.36ColumnacpmsTPFAvgStrread-onlycurrentTotal power factor average value since last reset.
1.3.6.1.4.1.3052.18.1.8.1.1.37ColumnacpmsTPFInEventStateread-onlycurrentTotal power factor event state.
1.3.6.1.4.1.3052.18.1.8.1.1.38ColumnacpmsPFPhaseAValueStrread-onlycurrentPhase A power factor.
1.3.6.1.4.1.3052.18.1.8.1.1.39ColumnacpmsPFPhaseBValueStrread-onlycurrentPhase B power factor.
1.3.6.1.4.1.3052.18.1.8.1.1.40ColumnacpmsPFPhaseCValueStrread-onlycurrentPhase C power factor.
1.3.6.1.4.1.3052.18.1.8.1.1.41ColumnacpmsTRcPValueStrread-onlycurrentTotal reactive power, in VAR.
1.3.6.1.4.1.3052.18.1.8.1.1.42ColumnacpmsTRcPMinStrread-onlycurrentTotal reactive power minimum value since last reset, in VAR.
1.3.6.1.4.1.3052.18.1.8.1.1.43ColumnacpmsTRcPMaxStrread-onlycurrentTotal reactive power maximum value since last reset, in VAR.
1.3.6.1.4.1.3052.18.1.8.1.1.44ColumnacpmsTRcPAvgStrread-onlycurrentTotal reactive power average value since last reset, in VAR.
1.3.6.1.4.1.3052.18.1.8.1.1.45ColumnacpmsRcPPhaseAValueStrread-onlycurrentPhase A reactive power, in VAR.
1.3.6.1.4.1.3052.18.1.8.1.1.46ColumnacpmsRcPPhaseBValueStrread-onlycurrentPhase B reactive power, in VAR.
1.3.6.1.4.1.3052.18.1.8.1.1.47ColumnacpmsRcPPhaseCValueStrread-onlycurrentPhase C reactive power, in VAR.
1.3.6.1.4.1.3052.18.1.8.1.1.48ColumnacpmsTAPValueStrread-onlycurrentTotal apparent power, in VA.
1.3.6.1.4.1.3052.18.1.8.1.1.49ColumnacpmsTAPMinStrread-onlycurrentTotal apparent power minimum value since last reset, in VA.
1.3.6.1.4.1.3052.18.1.8.1.1.50ColumnacpmsTAPMaxStrread-onlycurrentTotal apparent power maximum value since last reset, in VA.
1.3.6.1.4.1.3052.18.1.8.1.1.51ColumnacpmsTAPAvgStrread-onlycurrentTotal apparent power average value since last reset, in VA.
1.3.6.1.4.1.3052.18.1.8.1.1.52ColumnacpmsAPPhaseAValueStrread-onlycurrentPhase A apparent power, in VA.
1.3.6.1.4.1.3052.18.1.8.1.1.53ColumnacpmsAPPhaseBValueStrread-onlycurrentPhase B apparent power, in VA.
1.3.6.1.4.1.3052.18.1.8.1.1.54ColumnacpmsAPPhaseCValueStrread-onlycurrentPhase C apparent power, in VA.
1.3.6.1.4.1.3052.18.1.8.1.1.55ColumnacpmsTotalEnergyWhread-onlycurrentTotal energy, in Wh.
1.3.6.1.4.1.3052.18.1.8.1.1.56ColumnacpmsTotalEnergyVARread-onlycurrentTotal reactive energy, in VAR.
1.3.6.1.4.1.3052.18.1.8.1.1.57ColumnacpmsTotalEnergyVAread-onlycurrentTotal apparent energy, in VA.
1.3.6.1.4.1.3052.18.1.10NodebatteryMonitorStatus
1.3.6.1.4.1.3052.18.1.10.1TablebmStatusTablenot-accessiblecurrentBattery monitor status table.
1.3.6.1.4.1.3052.18.1.10.1.1RowbmStatusEntrynot-accessiblecurrentBattery monitor status table entry.
1.3.6.1.4.1.3052.18.1.10.1.1.1ColumnbmsIndexread-onlycurrentIndex for battery monitors.
1.3.6.1.4.1.3052.18.1.10.1.1.2ColumnbmsEnableread-onlycurrentON/OFF enable for this battery monitor.
1.3.6.1.4.1.3052.18.1.10.1.1.3ColumnbmsNameread-onlycurrentName for this battery monitor.
1.3.6.1.4.1.3052.18.1.10.1.1.4ColumnbmsStateread-onlycurrentThe connected state of the battery monitor. If you unplug the carrier then all three of its battery monitor states will reflect the same state change.
1.3.6.1.4.1.3052.18.1.10.1.1.5ColumnbmsStringStateread-onlycurrentState of the string monitored by its battery monitor.
1.3.6.1.4.1.3052.18.1.10.1.1.6ColumnbmsTempValueread-onlycurrentAverage jar temperature value in C or F, depending on scale setting. Displayed as a floating point value. -999.0 means this is unknown.
1.3.6.1.4.1.3052.18.1.10.1.1.7ColumnbmsTempValueStrread-onlycurrentAverage jar temperature with appropriate scale appended. Displayed as a floating point value. -999.0 means this is unknown.
1.3.6.1.4.1.3052.18.1.10.1.1.8ColumnbmsTempEventread-onlycurrentEvent state of this battery monitor average jar temperature (Low, Normal, High).
1.3.6.1.4.1.3052.18.1.10.1.1.9ColumnbmsDiffTempValueread-onlycurrentDifferential temperature in C or F, depending on scale setting. -999 means this is unknown.
1.3.6.1.4.1.3052.18.1.10.1.1.10ColumnbmsDiffTempValueStrread-onlycurrentDifferential temperature with appropriate scale (C or F) appended. -999 means this is unknown.
1.3.6.1.4.1.3052.18.1.10.1.1.11ColumnbmsDiffTempEventread-onlycurrentEvent state of this battery monitor differential temperature (Very High, High, Normal).
1.3.6.1.4.1.3052.18.1.10.1.1.12ColumnbmsVoltageValueread-onlycurrentTotal battery voltage on the string, in volts. Displayed as a floating point value in format X.X. -999.0 means this is unknown.
1.3.6.1.4.1.3052.18.1.10.1.1.13ColumnbmsVoltageEventread-onlycurrentEvent state of this battery monitor string voltage (Low, Normal, High, etc.).
1.3.6.1.4.1.3052.18.1.10.1.1.14ColumnbmsDiffVoltValueread-onlycurrentDifferential voltage in volts. Displayed as a floating point value in format X.X. -999.0 means this is unknown.
1.3.6.1.4.1.3052.18.1.10.1.1.15ColumnbmsDiffVoltEventread-onlycurrentEvent state of this battery monitor differential voltage (Very High, High, Normal.)
1.3.6.1.4.1.3052.18.1.10.1.1.16ColumnbmsCurrentValueread-onlycurrentCurrent flow on the string, in amperes. Displayed as a floating point value in format X.X. A positive value means the battery string is charging, and a negativ…
1.3.6.1.4.1.3052.18.1.10.1.1.17ColumnbmsChargingCurrentEventread-onlycurrentEvent state of this battery monitor charging current (Low, Normal, High, etc.).
1.3.6.1.4.1.3052.18.1.10.1.1.18ColumnbmsDischargingCurrentEventread-onlycurrentEvent state of this battery monitor discharging current (Low, Normal, High, etc.).
1.3.6.1.4.1.3052.18.1.10.1.1.19ColumnbmsChargeLevelValueread-onlycurrentCharge level of the battery string.
1.3.6.1.4.1.3052.18.1.10.1.1.20ColumnbmsChargeLevelEventread-onlycurrentEvent state of this battery monitor charge level (Very Low, Low, Normal).
1.3.6.1.4.1.3052.18.1.10.1.1.21ColumnbmsJarHealthValueread-onlycurrentJar health of the battery string.
1.3.6.1.4.1.3052.18.1.10.1.1.22ColumnbmsJarHealthEventread-onlycurrentEvent state of this battery monitor jar health (Very Low, Low, Normal).
1.3.6.1.4.1.3052.18.1.10.1.1.23ColumnbmsCombinedread-onlycurrentCombined status string intended to be parsed by NMS: name`deviceState`deviceStateColorCode`stringState`charge`voltage`temp`health~chargeEventState`chargeColorC…
1.3.6.1.4.1.3052.18.1.10.2TablebmsJarStatusTablenot-accessiblecurrentThis table organizes per-jar attributes of a battery monitor: 1. voltage 2. temperature.
1.3.6.1.4.1.3052.18.1.10.2.1RowbmJarStatusEntrynot-accessiblecurrentEntry for battery monitor jar status table. Note this table uses 2 SNMP indexes: the first for which battery monitor and the second for which jar.
1.3.6.1.4.1.3052.18.1.10.2.1.1ColumnbmjsIndexBMread-onlycurrentThe part of the index that refers to which battery monitor.
1.3.6.1.4.1.3052.18.1.10.2.1.2ColumnbmjsIndexJarread-onlycurrentThe part of the index that refers to which jar.
1.3.6.1.4.1.3052.18.1.10.2.1.3ColumnbmjsVoltageValueread-onlycurrentVoltage of individual battery cell. This is a floating point value in format X.X. -999.0 means this is unknown.
1.3.6.1.4.1.3052.18.1.10.2.1.4ColumnbmjsTempValueread-onlycurrentTemperature of individual battery jar. This is a floating point value. -999.0 means unknown.
1.3.6.1.4.1.3052.18.1.10.2.1.5ColumnbmjsAdmittanceValueread-onlycurrentCell admittance of individual jar. This is an integer value. -999 means unknown.
1.3.6.1.4.1.3052.18.1.10.2.1.6ColumnbmjsAdmittanceChangeValueread-onlycurrentPercent change of cell admittance of individual jar. This is an integer value.
1.3.6.1.4.1.3052.18.2Nodeconfig
1.3.6.1.4.1.3052.18.2.1NodeeventSensorBasics
1.3.6.1.4.1.3052.18.2.1.1ScalaresNumberEventSensorsread-onlycurrentThe number of EventSensors recognized by the unit, including the internal EventSensor. Range: 1-17
1.3.6.1.4.1.3052.18.2.1.2TableesTablenot-accessiblecurrentThe table of what EventSensors are attached to the unit, including the internal EventSensor
1.3.6.1.4.1.3052.18.2.1.2.1RowesEntrynot-accessiblecurrentTable entry for EventSensor table
1.3.6.1.4.1.3052.18.2.1.2.1.1ColumnesIndexread-onlycurrentThis number refers to an EventSensor; it has the same meaning as the esIndexES object (see above), except that this object is used only within the esTable bran…
1.3.6.1.4.1.3052.18.2.1.2.1.2ColumnesNameread-onlycurrentThe name of the EventSensor
1.3.6.1.4.1.3052.18.2.1.2.1.3ColumnesIDread-onlycurrentThe factory-assigned ID of the EventSensor
1.3.6.1.4.1.3052.18.2.1.2.1.4ColumnesNumberTempSensorsread-onlycurrentThe number of temperature sensors on the EventSensor
1.3.6.1.4.1.3052.18.2.1.2.1.5ColumnesTempReportingModeread-onlycurrentDescription of how temperature values should be interpreted.
1.3.6.1.4.1.3052.18.2.1.2.1.6ColumnesNumberCCsread-onlycurrentThe number of contact closures on the EventSensor.
1.3.6.1.4.1.3052.18.2.1.2.1.7ColumnesCCReportingModeread-onlycurrentDescription of how CC values should be interpreted.
1.3.6.1.4.1.3052.18.2.1.2.1.8ColumnesNumberHumidSensorsread-onlycurrentThe number of humidity sensors on the EventSensor.
1.3.6.1.4.1.3052.18.2.1.2.1.9ColumnesHumidReportingModeread-onlycurrentDescription of how humidity sensor values should be interpreted.
1.3.6.1.4.1.3052.18.2.1.2.1.10ColumnesNumberNoiseSensorsread-onlycurrentThe number of noise sensors on the EventSensor.
1.3.6.1.4.1.3052.18.2.1.2.1.11ColumnesNoiseReportingModeread-onlycurrentDescription of how noise sensor values should be interpreted.
1.3.6.1.4.1.3052.18.2.1.2.1.12ColumnesNumberAirflowSensorsread-onlycurrentThe number of airflow sensors on the EventSensor.
1.3.6.1.4.1.3052.18.2.1.2.1.13ColumnesAirflowReportingModeread-onlycurrentDescription of how airflow sensor values should be interpreted.
1.3.6.1.4.1.3052.18.2.1.2.1.14ColumnesNumberAnalogread-onlycurrentThe number of analog inputs on the EventSensor.
1.3.6.1.4.1.3052.18.2.1.2.1.15ColumnesAnalogReportingModeread-onlycurrentDescription of how analog input values should be interpreted.
1.3.6.1.4.1.3052.18.2.1.2.1.16ColumnesNumberOutputsread-onlycurrentThe number of outputs (relay or power) on the EventSensor
1.3.6.1.4.1.3052.18.2.1.2.1.17ColumnesOutputReportingModeread-onlycurrentDescription of how output values should be interpreted.
1.3.6.1.4.1.3052.18.2.1.2.1.18ColumnesTempCombinedStatusread-onlycurrentCombined status string intended to be parsed by NMS: name`value`scale`eventState`eventColorCode
1.3.6.1.4.1.3052.18.2.1.2.1.19ColumnesCCCombinedStatusBlock1read-onlycurrentCombined status string intended to be parsed by NMS: numInBlock~name1`value1`eventColorCode1`alias1~name2`value2`eventColorCode2`alias2~...name8`value8`eventCo…
1.3.6.1.4.1.3052.18.2.1.2.1.20ColumnesCCCombinedStatusBlock2read-onlycurrentCombined status string intended to be parsed by NMS: numInBlock~name9`value9`eventColorCode9`alias9~name10`value10`eventColorCode10`alias10~...name16`value16`e…
1.3.6.1.4.1.3052.18.2.1.2.1.21ColumnesCCCombinedStatusBlock3read-onlycurrentCombined status string intended to be parsed by NMS: numInBlock~name17`value17`eventColorCode17`alias17~name18`value18`eventColorCode18`alias18~...name24`value…
1.3.6.1.4.1.3052.18.2.1.2.1.22ColumnesCCCombinedStatusBlock4read-onlycurrentCombined status string intended to be parsed by NMS: numInBlock~name25`value25`eventColorCode25`alias25~name26`value26`eventColorCode26`alias26~...name32`value…
1.3.6.1.4.1.3052.18.2.1.2.1.23ColumnesCCCombinedStatusBlock5read-onlycurrentCombined status string intended to be parsed by NMS: numInBlock~name33`value33`eventColorCode33`alias33~name34`value34`eventColorCode34`alias35~...name40`value…
1.3.6.1.4.1.3052.18.2.1.2.1.24ColumnesCCCombinedStatusBlock6read-onlycurrentCombined status string intended to be parsed by NMS: numInBlock~name41`value41`eventColorCode41`alias41~name42`value42`eventColorCode42`alias43~...name48`value…
1.3.6.1.4.1.3052.18.2.1.2.1.25ColumnesCCCombinedStatusBlock7read-onlycurrentCombined status string intended to be parsed by NMS: numInBlock~name49`value49`eventColorCode49`alias49~name50`value50`eventColorCode50`alias50~...name56`value…
1.3.6.1.4.1.3052.18.2.1.2.1.26ColumnesCCCombinedStatusBlock8read-onlycurrentCombined status string intended to be parsed by NMS: numInBlock~name57`value57`eventColorCode57`alias57~name57`value57`eventColorCode564`alias57~...name64`valu…
1.3.6.1.4.1.3052.18.2.1.2.1.27ColumnesHumidCombinedStatusread-onlycurrentCombined status string intended to be parsed by NMS: name`value`eventState`eventColorCode
1.3.6.1.4.1.3052.18.2.1.2.1.28ColumnesAnalogCombinedStatusBlock1read-onlycurrentCombined status string intended to be parsed by NMS: numInBlock~name1`value1`units1`eventState`eventColorCode1~name2`value2`units2`eventState`eventColorCode2~.…
1.3.6.1.4.1.3052.18.2.1.2.1.29ColumnesAnalogCombinedStatusBlock2read-onlycurrentCombined status string intended to be parsed by NMS: numInBlock~name9`value9`units9`eventState9`eventColorCode9~...
1.3.6.1.4.1.3052.18.2.1.2.1.30ColumnesAnalogCombinedStatusBlock3read-onlycurrentCombined status string intended to be parsed by NMS: numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~...
1.3.6.1.4.1.3052.18.2.1.2.1.31ColumnesAnalogCombinedStatusBlock4read-onlycurrentCombined status string intended to be parsed by NMS: numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~...
1.3.6.1.4.1.3052.18.2.1.2.1.32ColumnesAnalogCombinedStatusBlock5read-onlycurrentCombined status string intended to be parsed by NMS: numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~...
1.3.6.1.4.1.3052.18.2.1.2.1.33ColumnesAnalogCombinedStatusBlock6read-onlycurrentCombined status string intended to be parsed by NMS: numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~...
1.3.6.1.4.1.3052.18.2.1.2.1.34ColumnesOutputCombinedStatusBlock1read-onlycurrentCombined status string intended to be parsed by NMS: numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~...
1.3.6.1.4.1.3052.18.2.1.2.1.35ColumnesOutputCombinedStatusBlock2read-onlycurrentCombined status string intended to be parsed by NMS: numInBlock`namex`valuex`aliasx~namey`valuey`aliasy~...namez`valuez`aliasz
1.3.6.1.4.1.3052.18.2.1.3ScalaresNewSensorsread-onlycurrentString representing the number of new (attached but unconfigured) EventSensors
1.3.6.1.4.1.3052.18.2.2NodeeventSensorPointConfig
1.3.6.1.4.1.3052.18.2.2.1TableesPointConfigTempTablenot-accessiblecurrentThis table organizes 3 basic attributes of temperature sensor points. A point is a particular sensor on an EventSensor. The 3 point attributes organizes in thi…
1.3.6.1.4.1.3052.18.2.2.1.1RowesPointConfigTempEntrynot-accessiblecurrentEntry for EventSensor point config temperature table
1.3.6.1.4.1.3052.18.2.2.1.1.1ColumnespcTempIndexESread-onlycurrentThe part of the point index that refers to an EventSensor. The point config index is a string of 2 numbers separated by a period. It contains all the informati…
1.3.6.1.4.1.3052.18.2.2.1.1.2ColumnespcTempIndexPointread-onlycurrentThe part of the point index that delineates which sensor on the EventSensor. So this combined with espcTempIndexES (which EventSensor) uniquely defines each po…
1.3.6.1.4.1.3052.18.2.2.1.1.3ColumnespcTempEnableread-writecurrentON/OFF enable this temperature sensor
1.3.6.1.4.1.3052.18.2.2.1.1.4ColumnespcTempScaleread-writecurrentScale (C/F) for this temperature sensor
1.3.6.1.4.1.3052.18.2.2.1.1.5ColumnespcTempDeadbandread-writecurrentDeadband for this temperature sensor (in floating-point format)
1.3.6.1.4.1.3052.18.2.2.1.1.6ColumnespcTempVHighTempread-writecurrentVery high temperature event threshold for this temperature sensor (in floating-point format)
1.3.6.1.4.1.3052.18.2.2.1.1.7ColumnespcTempVHighActionsread-writecurrentVery high temperature event actions for this temperature sensor
1.3.6.1.4.1.3052.18.2.2.1.1.8ColumnespcTempVHighTrapnumread-writecurrentVery high temperature event trap number for this temperature sensor
1.3.6.1.4.1.3052.18.2.2.1.1.9ColumnespcTempVHighClassread-writecurrentVery high temperature event class for this temperature sensor
1.3.6.1.4.1.3052.18.2.2.1.1.10ColumnespcTempHighTempread-writecurrentHigh temperature event threshold for this temperature sensor (in floating-point format)
1.3.6.1.4.1.3052.18.2.2.1.1.11ColumnespcTempHighActionsread-writecurrentHigh temperature event actions for this temperature sensor
1.3.6.1.4.1.3052.18.2.2.1.1.12ColumnespcTempHighTrapnumread-writecurrentHigh temperature event trap number for this temperature sensor
1.3.6.1.4.1.3052.18.2.2.1.1.13ColumnespcTempHighClassread-writecurrentHigh temperature event class for this temperature sensor
1.3.6.1.4.1.3052.18.2.2.1.1.14ColumnespcTempNormalActionsread-writecurrentReturn-to-normal event actions for this temperature sensor
1.3.6.1.4.1.3052.18.2.2.1.1.15ColumnespcTempNormalTrapnumread-writecurrentReturn-to-normal event trap number for this temperature sensor
1.3.6.1.4.1.3052.18.2.2.1.1.16ColumnespcTempNormalClassread-writecurrentReturn-to-normal event class for this temperature sensor
1.3.6.1.4.1.3052.18.2.2.1.1.17ColumnespcTempLowTempread-writecurrentLow temperature event threshold for this temperature sensor (in floating-point format)
1.3.6.1.4.1.3052.18.2.2.1.1.18ColumnespcTempLowActionsread-writecurrentLow temperature event actions for this temperature sensor
1.3.6.1.4.1.3052.18.2.2.1.1.19ColumnespcTempLowTrapnumread-writecurrentLow temperature event trap number for this temperature sensor
1.3.6.1.4.1.3052.18.2.2.1.1.20ColumnespcTempLowClassread-writecurrentLow temperature event class for this temperature sensor
1.3.6.1.4.1.3052.18.2.2.1.1.21ColumnespcTempVLowTempread-writecurrentVery Low temperature event threshold for this temperature sensor (in floating-point format)
1.3.6.1.4.1.3052.18.2.2.1.1.22ColumnespcTempVLowActionsread-writecurrentVery Low temperature event actions for this temperature sensor
1.3.6.1.4.1.3052.18.2.2.1.1.23ColumnespcTempVLowTrapnumread-writecurrentVery Low temperature event trap number for this temperature sensor
1.3.6.1.4.1.3052.18.2.2.1.1.24ColumnespcTempVLowClassread-writecurrentVery Low temperature event class for this temperature sensor
1.3.6.1.4.1.3052.18.2.2.2TableesPointConfigCCTablenot-accessiblecurrentThis table organizes 3 basic attributes of contact closure points. A point is a particular sensor on an EventSensor. The 3 point attributes organizes in this t…
1.3.6.1.4.1.3052.18.2.2.2.1RowesPointConfigCCEntrynot-accessiblecurrentEntry for EventSensor point config contact closure table
1.3.6.1.4.1.3052.18.2.2.2.1.1ColumnespcCCIndexESread-onlycurrentThe part of the point index that refers to an EventSensor. The point config index is a string of 2 numbers separated by a period. It contains all the informati…
1.3.6.1.4.1.3052.18.2.2.2.1.2ColumnespcCCIndexPointread-onlycurrentThe part of the point index that delineates which sensor on the EventSensor. So this combined with espcCCIndexES (which EventSensor) uniquely defines each poin…
1.3.6.1.4.1.3052.18.2.2.2.1.3ColumnespcCCEnableread-writecurrentON/OFF enable for this contact closure
1.3.6.1.4.1.3052.18.2.2.2.1.4ColumnespcCCNameread-writecurrentName for this contact closure
1.3.6.1.4.1.3052.18.2.2.2.1.5ColumnespcCCEventStateread-writecurrentEvent state for this contact closure
1.3.6.1.4.1.3052.18.2.2.2.1.6ColumnespcCCThresholdread-writecurrentEvent threshold (seconds) for this contact closure
1.3.6.1.4.1.3052.18.2.2.2.1.7ColumnespcCCEventActionsread-writecurrentEvent actions for this contact closure
1.3.6.1.4.1.3052.18.2.2.2.1.8ColumnespcCCEventTrapnumread-writecurrentEvent trap number for this contact closure
1.3.6.1.4.1.3052.18.2.2.2.1.9ColumnespcCCEventClassread-writecurrentEvent class for this contact closure
1.3.6.1.4.1.3052.18.2.2.2.1.10ColumnespcCCNormalActionsread-writecurrentReturn-to-normal actions for this contact closure
1.3.6.1.4.1.3052.18.2.2.2.1.11ColumnespcCCNormalTrapnumread-writecurrentReturn-to-normal trap number for this contact closure
1.3.6.1.4.1.3052.18.2.2.2.1.12ColumnespcCCNormalClassread-writecurrentReturn-to-normal class for this contact closure
1.3.6.1.4.1.3052.18.2.2.2.1.13ColumnespcCCAlarmAliasread-writecurrentEvent alias for this contact closure
1.3.6.1.4.1.3052.18.2.2.2.1.14ColumnespcCCNormalAliasread-writecurrentReturn-to-normal alias for this contact closure
1.3.6.1.4.1.3052.18.2.2.2.1.15ColumnespcCCNormalThresholdread-writecurrentEvent threshold (seconds) for this contact closure to return to normal
1.3.6.1.4.1.3052.18.2.2.2.1.16ColumnespcCCOverrideGlobalReminderread-writecurrentOverride global reminder interval (evReminderInterval) for this CC.
1.3.6.1.4.1.3052.18.2.2.2.1.17ColumnespcCCReminderIntervalread-writecurrentIndividual reminder interval for this CC, applicable when the global reminder is overriden.
1.3.6.1.4.1.3052.18.2.2.3TableesPointConfigHumidTablenot-accessiblecurrentThis table organizes 3 basic attributes of humidity points. A point is a particular sensor on an EventSensor. The 3 point attributes organizes in this table ar…
1.3.6.1.4.1.3052.18.2.2.3.1RowesPointConfigHumidEntrynot-accessiblecurrentEntry for EventSensor point config humidity table
1.3.6.1.4.1.3052.18.2.2.3.1.1ColumnespcHumidIndexESread-onlycurrentThe part of the point index that refers to an EventSensor. The point config index is a string of 2 numbers separated by a period. It contains all the informati…
1.3.6.1.4.1.3052.18.2.2.3.1.2ColumnespcHumidIndexPointread-onlycurrentThe part of the point index that delineates which sensor on the EventSensor. So this combined with espcHumidIndexES (which EventSensor) uniquely defines each p…
1.3.6.1.4.1.3052.18.2.2.3.1.3ColumnespcHumidEnableread-writecurrentON/OFF enable for this humidity sensor
1.3.6.1.4.1.3052.18.2.2.3.1.4ColumnespcHumidDeadbandread-writecurrentDeadband for this humidity sensor
1.3.6.1.4.1.3052.18.2.2.3.1.5ColumnespcHumidVHighHumidread-writecurrentVery high event threshold for this humidity sensor
1.3.6.1.4.1.3052.18.2.2.3.1.6ColumnespcHumidVHighActionsread-writecurrentVery high event actions for this humidity sensor
1.3.6.1.4.1.3052.18.2.2.3.1.7ColumnespcHumidVHighTrapnumread-writecurrentVery high event trap number for this humidity sensor
1.3.6.1.4.1.3052.18.2.2.3.1.8ColumnespcHumidVHighClassread-writecurrentVery high event class for this humidity sensor
1.3.6.1.4.1.3052.18.2.2.3.1.9ColumnespcHumidHighHumidread-writecurrentHigh event threshold for this humidity sensor
1.3.6.1.4.1.3052.18.2.2.3.1.10ColumnespcHumidHighActionsread-writecurrentHigh event actions for this humidity sensor
1.3.6.1.4.1.3052.18.2.2.3.1.11ColumnespcHumidHighTrapnumread-writecurrentHigh event trap number for this humidity sensor
1.3.6.1.4.1.3052.18.2.2.3.1.12ColumnespcHumidHighClassread-writecurrentHigh event class for this humidity sensor
1.3.6.1.4.1.3052.18.2.2.3.1.13ColumnespcHumidNormalActionsread-writecurrentReturn-to-normal actions for this humidity sensor
1.3.6.1.4.1.3052.18.2.2.3.1.14ColumnespcHumidNormalTrapnumread-writecurrentReturn-to-normal trap number for this humidity sensor
1.3.6.1.4.1.3052.18.2.2.3.1.15ColumnespcHumidNormalClassread-writecurrentReturn-to-normal class for this humidity sensor
1.3.6.1.4.1.3052.18.2.2.3.1.16ColumnespcHumidLowHumidread-writecurrentLow event threshold for this humidity sensor
1.3.6.1.4.1.3052.18.2.2.3.1.17ColumnespcHumidLowActionsread-writecurrentLow event actions for this humidity sensor
1.3.6.1.4.1.3052.18.2.2.3.1.18ColumnespcHumidLowTrapnumread-writecurrentLow event trap number for this humidity sensor
1.3.6.1.4.1.3052.18.2.2.3.1.19ColumnespcHumidLowClassread-writecurrentLow event class for this humidity sensor
1.3.6.1.4.1.3052.18.2.2.3.1.20ColumnespcHumidVLowHumidread-writecurrentVery low event threshold for this humidity sensor
1.3.6.1.4.1.3052.18.2.2.3.1.21ColumnespcHumidVLowActionsread-writecurrentVery low event actions for this humidity sensor
1.3.6.1.4.1.3052.18.2.2.3.1.22ColumnespcHumidVLowTrapnumread-writecurrentVery low event trap number for this humidity sensor
1.3.6.1.4.1.3052.18.2.2.3.1.23ColumnespcHumidVLowClassread-writecurrentVery low event class for this humidity sensor
1.3.6.1.4.1.3052.18.2.2.5TableesPointConfigAITablenot-accessiblecurrentThis table organizes 3 basic attributes of analog input points. A point is a particular sensor on an EventSensor. The 3 point attributes organizes in this tabl…
1.3.6.1.4.1.3052.18.2.2.5.1RowesPointConfigAIEntrynot-accessiblecurrentEntry for EventSensor point config analog input table
1.3.6.1.4.1.3052.18.2.2.5.1.1ColumnespcAIIndexESread-onlycurrentThe part of the point index that refers to an EventSensor. The point config index is a string of 2 numbers separated by a period. It contains all the informati…
1.3.6.1.4.1.3052.18.2.2.5.1.2ColumnespcAIIndexPointread-onlycurrentThe part of the point index that delineates which sensor on the EventSensor. So this combined with espcAIIndexES (which EventSensor) uniquely defines each poin…
1.3.6.1.4.1.3052.18.2.2.5.1.3ColumnespcAIEnableread-writecurrentON/OFF for this analog input sensor
1.3.6.1.4.1.3052.18.2.2.5.1.5ColumnespcAIDeadbandread-writecurrentDeadband for this analog input sensor
1.3.6.1.4.1.3052.18.2.2.5.1.6ColumnespcAIVhighValueread-writecurrentVery high event threshold (decivolts or tenths of milliamps) for this analog input sensor
1.3.6.1.4.1.3052.18.2.2.5.1.7ColumnespcAIVhighActionsread-writecurrentVery high event actions for this analog input sensor
1.3.6.1.4.1.3052.18.2.2.5.1.8ColumnespcAIVhighTrapnumread-writecurrentVery high event trap number for this analog input sensor
1.3.6.1.4.1.3052.18.2.2.5.1.9ColumnespcAIVhighClassread-writecurrentVery high event class for this analog input sensor
1.3.6.1.4.1.3052.18.2.2.5.1.10ColumnespcAIHighValueread-writecurrentHigh event threshold (decivolts or tenths of milliamps) for this analog input sensor
1.3.6.1.4.1.3052.18.2.2.5.1.11ColumnespcAIHighActionsread-writecurrentHigh event actions for this analog input sensor
1.3.6.1.4.1.3052.18.2.2.5.1.12ColumnespcAIHighTrapnumread-writecurrentHigh event trap number for this analog input sensor
1.3.6.1.4.1.3052.18.2.2.5.1.13ColumnespcAIHighClassread-writecurrentHigh event class for this analog input sensor
1.3.6.1.4.1.3052.18.2.2.5.1.14ColumnespcAINormalActionsread-writecurrentReturn-to-normal actions for this analog input sensor
1.3.6.1.4.1.3052.18.2.2.5.1.15ColumnespcAINormalTrapnumread-writecurrentReturn-to-normal trap number for this analog input sensor
1.3.6.1.4.1.3052.18.2.2.5.1.16ColumnespcAINormalClassread-writecurrentReturn-to-normal class for this analog input sensor
1.3.6.1.4.1.3052.18.2.2.5.1.17ColumnespcAILowValueread-writecurrentLow event threshold (decivolts or tenths of milliamps) for this analog input sensor
1.3.6.1.4.1.3052.18.2.2.5.1.18ColumnespcAILowActionsread-writecurrentLow event actions for this analog input sensor
1.3.6.1.4.1.3052.18.2.2.5.1.19ColumnespcAILowTrapnumread-writecurrentLow event trap number for this analog input sensor
1.3.6.1.4.1.3052.18.2.2.5.1.20ColumnespcAILowClassread-writecurrentLow event class for this analog input sensor
1.3.6.1.4.1.3052.18.2.2.5.1.21ColumnespcAIVlowValueread-writecurrentVery low event threshold (decivolts or tenths of milliamps) for this analog input sensor
1.3.6.1.4.1.3052.18.2.2.5.1.22ColumnespcAIVlowActionsread-writecurrentVery low event actions for this analog input sensor
1.3.6.1.4.1.3052.18.2.2.5.1.23ColumnespcAIVlowTrapnumread-writecurrentVery low event actions for this analog input sensor
1.3.6.1.4.1.3052.18.2.2.5.1.24ColumnespcAIVlowClassread-writecurrentVery low event class for this analog input sensor
1.3.6.1.4.1.3052.18.2.2.5.1.25ColumnespcAIConvUnitNameread-writecurrentConverstion unit name for this analog input sensor
1.3.6.1.4.1.3052.18.2.2.5.1.26ColumnespcAIConvHighValueread-writecurrentConversion high value for this analog input sensor
1.3.6.1.4.1.3052.18.2.2.5.1.27ColumnespcAIConvHighUnitread-writecurrentConversion high unit value for this analog input sensor
1.3.6.1.4.1.3052.18.2.2.5.1.29ColumnespcAIConvLowValueread-writecurrentConversion low value for this analog input sensor
1.3.6.1.4.1.3052.18.2.2.5.1.30ColumnespcAIConvLowUnitread-writecurrentConversion unit low unit value for this analog input sensor
1.3.6.1.4.1.3052.18.2.2.5.1.32ColumnespcAIDisplayFormatread-writecurrentAnalog input display format
1.3.6.1.4.1.3052.18.2.2.6TableesPointConfigOutputTablenot-accessiblecurrentThis table organizes configuration items for output points. A point is a particular sensor on an EventSensor. The 3 point attributes organized in this table ar…
1.3.6.1.4.1.3052.18.2.2.6.1RowesPointConfigOutputEntrynot-accessiblecurrentEntry for EventSensor point config output table
1.3.6.1.4.1.3052.18.2.2.6.1.1ColumnespcOutputIndexESread-onlycurrentThe part of the point index that refers to an EventSensor. The point config index is a string of 2 numbers separated by a period. It contains all the informati…
1.3.6.1.4.1.3052.18.2.2.6.1.2ColumnespcOutputIndexPointread-onlycurrentThe part of the point index that delineates which sensor on the EventSensor. So this combined with espcOutputIndexES (which EventSensor) uniquely defines each …
1.3.6.1.4.1.3052.18.2.2.6.1.3ColumnespcOutputEnableread-writecurrentEnables the output event for this output. This has no effect on whether the relay changes state, only on whether a state change triggers an event.
1.3.6.1.4.1.3052.18.2.2.6.1.4ColumnespcOutputActiveStateread-writecurrentWhich state is considered the active state: energized/de-energized.
1.3.6.1.4.1.3052.18.2.2.6.1.5ColumnespcOutputTyperead-onlycurrentOutput type: RELAY, POWER, SSR, TTL.
1.3.6.1.4.1.3052.18.2.2.6.1.6ColumnespcOutputAliasValueread-onlycurrentOutput alias corresponding to its event state.
1.3.6.1.4.1.3052.18.2.2.6.1.7ColumnespcOutputAliasColorread-onlycurrentOutput color corresponding to its event state.
1.3.6.1.4.1.3052.18.2.2.6.1.10ColumnespcOutputActiveAliasread-writecurrentAlias for the output active state.
1.3.6.1.4.1.3052.18.2.2.6.1.11ColumnespcOutputActiveColorread-writecurrentOutput color (as rendered in the web UI, in RGB hex format) corresponding to the output active state.
1.3.6.1.4.1.3052.18.2.2.6.1.12ColumnespcOutputActiveActionsread-writecurrentActions for the output active event.
1.3.6.1.4.1.3052.18.2.2.6.1.13ColumnespcOutputActiveTrapnumread-writecurrentActions for the output active event.
1.3.6.1.4.1.3052.18.2.2.6.1.14ColumnespcOutputActiveClassread-writecurrentClass (severity) for the output active event.
1.3.6.1.4.1.3052.18.2.2.6.1.20ColumnespcOutputInactiveAliasread-writecurrentAlias for the output inactive state.
1.3.6.1.4.1.3052.18.2.2.6.1.21ColumnespcOutputInactiveColorread-writecurrentOutput color (as rendered in the web UI, in RGB hex format) corresponding to the output inactive state.
1.3.6.1.4.1.3052.18.2.2.6.1.22ColumnespcOutputInactiveActionsread-writecurrentActions for the output inactive event.
1.3.6.1.4.1.3052.18.2.2.6.1.23ColumnespcOutputInactiveTrapnumread-writecurrentActions for the output inactive event.
1.3.6.1.4.1.3052.18.2.2.6.1.24ColumnespcOutputInactiveClassread-writecurrentClass (severity) for the output inactive event.
1.3.6.1.4.1.3052.18.2.3NodeserialPorts
1.3.6.1.4.1.3052.18.2.3.1ScalarnumberPortsread-onlycurrentNumber of RS-232 ports found. Range: 2 or 4
1.3.6.1.4.1.3052.18.2.3.2TableportConfigTablenot-accessiblecurrentPort config table
1.3.6.1.4.1.3052.18.2.3.2.1RowportConfigEntrynot-accessiblecurrentPort config entry
1.3.6.1.4.1.3052.18.2.3.2.1.1ColumnportConfigIndexread-onlycurrentIndex for ports
1.3.6.1.4.1.3052.18.2.3.2.1.2ColumnportConfigBaudread-writecurrentBaud rate, 19200, 9600, etc.
1.3.6.1.4.1.3052.18.2.3.2.1.3ColumnportConfigDataFormatread-writecurrentValue representing word length, parity, and stop bits: 0=8N1, 1=7E1, 2=7O1, 3=7N1, 4=8O2
1.3.6.1.4.1.3052.18.2.3.2.1.4ColumnportConfigStripPtOutputLfsread-writecurrentStrip passthrough LFs sent to device on this port: 1=yes, 0=no.
1.3.6.1.4.1.3052.18.2.3.2.1.5ColumnportConfigStripPtInputLfsread-writecurrentStrip passthrough LFs received from device on this port: 1=yes, 0=no.
1.3.6.1.4.1.3052.18.2.3.2.1.27ColumnportConfigIdread-writecurrentThe text identifer for the port
1.3.6.1.4.1.3052.18.2.3.2.1.28ColumnportConfigModeread-writecurrentMode of the serial port.
1.3.6.1.4.1.3052.18.2.3.2.1.29ColumnportConfigHskread-writecurrentHandshaking mode of the serial port.
1.3.6.1.4.1.3052.18.2.4Nodenetwork
1.3.6.1.4.1.3052.18.2.4.1Nodeinterface
1.3.6.1.4.1.3052.18.2.4.1.1Nodeethernet
1.3.6.1.4.1.3052.18.2.4.1.1.1Nodeethernet1
1.3.6.1.4.1.3052.18.2.4.1.1.1.1Scalareth1Moderead-onlycurrentMode of the Ethernet1 interface: STATIC,DHCP,VLAN
1.3.6.1.4.1.3052.18.2.4.1.1.1.2Scalareth1Addressread-writecurrentEthernet1 IP address
1.3.6.1.4.1.3052.18.2.4.1.1.1.3Scalareth1SubnetMaskread-writecurrentEthernet1 subnet mask
1.3.6.1.4.1.3052.18.2.4.1.1.1.4Scalareth1Routerread-writecurrentEthernet1 router
1.3.6.1.4.1.3052.18.2.4.1.1.1.5Nodeeth1VLAN
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.1Nodeeth1VLAN1
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.1.1Scalareth1VLAN1IDread-writecurrentEthernet1 VLAN1 ID
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.1.2Scalareth1VLAN1Priorityread-writecurrentEthernet1 VLAN1 priority
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.1.3Scalareth1VLAN1Addressread-writecurrentEthernet1 VLAN1 IP address
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.1.4Scalareth1VLAN1SubnetMaskread-writecurrentEthernet1 VLAN1 subnet mask
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.1.5Scalareth1VLAN1Routerread-writecurrentEthernet1 VLAN1 router
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.2Nodeeth1VLAN2
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.2.1Scalareth1VLAN2IDread-writecurrentEthernet1 VLAN2 ID
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.2.2Scalareth1VLAN2Priorityread-writecurrentEthernet1 VLAN2 priority
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.2.3Scalareth1VLAN2Addressread-writecurrentEthernet1 VLAN2 IP address
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.2.4Scalareth1VLAN2SubnetMaskread-writecurrentEthernet1 VLAN2 subnet mask
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.2.5Scalareth1VLAN2Routerread-writecurrentEthernet1 VLAN2 router
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.3Nodeeth1VLAN3
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.3.1Scalareth1VLAN3IDread-writecurrentEthernet1 VLAN3 ID
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.3.2Scalareth1VLAN3Priorityread-writecurrentEthernet1 VLAN3 priority
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.3.3Scalareth1VLAN3Addressread-writecurrentEthernet1 VLAN3 IP address
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.3.4Scalareth1VLAN3SubnetMaskread-writecurrentEthernet1 VLAN3 subnet mask
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.3.5Scalareth1VLAN3Routerread-writecurrentEthernet1 VLAN3 router
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.4Nodeeth1VLAN4
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.4.1Scalareth1VLAN4IDread-writecurrentEthernet1 VLAN4 ID
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.4.2Scalareth1VLAN4Priorityread-writecurrentEthernet1 VLAN4 priority
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.4.3Scalareth1VLAN4Addressread-writecurrentEthernet1 VLAN4 IP address
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.4.4Scalareth1VLAN4SubnetMaskread-writecurrentEthernet1 VLAN4 subnet mask
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.4.5Scalareth1VLAN4Routerread-writecurrentEthernet1 VLAN4 router
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.5Nodeeth1VLAN5
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.5.1Scalareth1VLAN5IDread-writecurrentEthernet1 VLAN5 ID
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.5.2Scalareth1VLAN5Priorityread-writecurrentEthernet1 VLAN5 priority
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.5.3Scalareth1VLAN5Addressread-writecurrentEthernet1 VLAN5 IP address
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.5.4Scalareth1VLAN5SubnetMaskread-writecurrentEthernet1 VLAN5 subnet mask
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.5.5Scalareth1VLAN5Routerread-writecurrentEthernet1 VLAN5 router
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.6Nodeeth1VLAN6
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.6.1Scalareth1VLAN6IDread-writecurrentEthernet1 VLAN6 ID
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.6.2Scalareth1VLAN6Priorityread-writecurrentEthernet1 VLAN6 priority
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.6.3Scalareth1VLAN6Addressread-writecurrentEthernet1 VLAN6 IP address
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.6.4Scalareth1VLAN6SubnetMaskread-writecurrentEthernet1 VLAN6 subnet mask
1.3.6.1.4.1.3052.18.2.4.1.1.1.5.6.5Scalareth1VLAN6Routerread-writecurrentEthernet1 VLAN6 router
1.3.6.1.4.1.3052.18.2.4.1.1.1.6Scalareth1MACread-onlycurrentEthernet1 MAC
1.3.6.1.4.1.3052.18.2.4.1.1.1.7Nodeeth1IPv6
1.3.6.1.4.1.3052.18.2.4.1.1.1.7.1Scalareth1IPv6Moderead-writecurrentControls IPv6 operation for this Ethernet interface.
1.3.6.1.4.1.3052.18.2.4.1.1.1.7.2Nodeeth1IPv6Static
1.3.6.1.4.1.3052.18.2.4.1.1.1.7.2.1Scalareth1IPv6StaticAddressread-writecurrenthe static IPv6 address to use for this interface when in operating in STATIC mode.
1.3.6.1.4.1.3052.18.2.4.1.1.1.7.2.2Scalareth1IPv6StaticRouterread-writecurrentThe IPv6 router to engage as the default router when this interface operates in STATIC mode.
1.3.6.1.4.1.3052.18.2.4.1.1.1.7.3Nodeeth1IPv6Auto
1.3.6.1.4.1.3052.18.2.4.1.1.1.7.3.1Scalareth1IPv6AutoAddress1read-onlycurrentOne of the automatically-acquired IPv6 addresses.
1.3.6.1.4.1.3052.18.2.4.1.1.1.7.3.2Scalareth1IPv6AutoAddress2read-onlycurrentOne of the automatically-acquired IPv6 addresses.
1.3.6.1.4.1.3052.18.2.4.1.1.1.7.3.3Scalareth1IPv6AutoAddress3read-onlycurrentOne of the automatically-acquired IPv6 addresses.
1.3.6.1.4.1.3052.18.2.4.1.1.1.7.3.4Scalareth1IPv6AutoAddress4read-onlycurrentOne of the automatically-acquired IPv6 addresses.
1.3.6.1.4.1.3052.18.2.4.1.1.1.7.4Scalareth1IPv6LinkLocalAddressread-onlycurrentThe link local IPv6 address for this interface. This is present when the IPv6 mode is not OFF.
1.3.6.1.4.1.3052.18.2.4.1.1.2Nodeethernet2
1.3.6.1.4.1.3052.18.2.4.1.1.2.1Scalareth2Moderead-onlycurrentMode of the Ethernet2 interface: STATIC,DHCP,VLAN
1.3.6.1.4.1.3052.18.2.4.1.1.2.2Scalareth2Addressread-writecurrentEthernet2 IP address
1.3.6.1.4.1.3052.18.2.4.1.1.2.3Scalareth2SubnetMaskread-writecurrentEthernet2 subnet mask
1.3.6.1.4.1.3052.18.2.4.1.1.2.4Scalareth2Routerread-writecurrentEthernet2 router
1.3.6.1.4.1.3052.18.2.4.1.1.2.5Nodeeth2VLAN
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.1Nodeeth2VLAN1
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.1.1Scalareth2VLAN1IDread-writecurrentEthernet2 VLAN1 ID
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.1.2Scalareth2VLAN1Priorityread-writecurrentEthernet2 VLAN1 priority
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.1.3Scalareth2VLAN1Addressread-writecurrentEthernet2 VLAN1 IP address
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.1.4Scalareth2VLAN1SubnetMaskread-writecurrentEthernet2 VLAN1 subnet mask
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.1.5Scalareth2VLAN1Routerread-writecurrentEthernet2 VLAN1 router
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.2Nodeeth2VLAN2
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.2.1Scalareth2VLAN2IDread-writecurrentEthernet2 VLAN2 ID
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.2.2Scalareth2VLAN2Priorityread-writecurrentEthernet2 VLAN2 priority
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.2.3Scalareth2VLAN2Addressread-writecurrentEthernet2 VLAN2 IP address
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.2.4Scalareth2VLAN2SubnetMaskread-writecurrentEthernet2 VLAN2 subnet mask
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.2.5Scalareth2VLAN2Routerread-writecurrentEthernet2 VLAN2 router
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.3Nodeeth2VLAN3
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.3.1Scalareth2VLAN3IDread-writecurrentEthernet2 VLAN3 ID
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.3.2Scalareth2VLAN3Priorityread-writecurrentEthernet2 VLAN3 priority
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.3.3Scalareth2VLAN3Addressread-writecurrentEthernet2 VLAN3 IP address
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.3.4Scalareth2VLAN3SubnetMaskread-writecurrentEthernet2 VLAN3 subnet mask
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.3.5Scalareth2VLAN3Routerread-writecurrentEthernet2 VLAN3 router
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.4Nodeeth2VLAN4
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.4.1Scalareth2VLAN4IDread-writecurrentEthernet2 VLAN4 ID
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.4.2Scalareth2VLAN4Priorityread-writecurrentEthernet2 VLAN4 priority
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.4.3Scalareth2VLAN4Addressread-writecurrentEthernet2 VLAN4 IP address
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.4.4Scalareth2VLAN4SubnetMaskread-writecurrentEthernet2 VLAN4 subnet mask
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.4.5Scalareth2VLAN4Routerread-writecurrentEthernet2 VLAN4 router
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.5Nodeeth2VLAN5
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.5.1Scalareth2VLAN5IDread-writecurrentEthernet2 VLAN5 ID
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.5.2Scalareth2VLAN5Priorityread-writecurrentEthernet2 VLAN5 priority
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.5.3Scalareth2VLAN5Addressread-writecurrentEthernet2 VLAN5 IP address
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.5.4Scalareth2VLAN5SubnetMaskread-writecurrentEthernet2 VLAN5 subnet mask
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.5.5Scalareth2VLAN5Routerread-writecurrentEthernet2 VLAN5 router
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.6Nodeeth2VLAN6
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.6.1Scalareth2VLAN6IDread-writecurrentEthernet2 VLAN6 ID
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.6.2Scalareth2VLAN6Priorityread-writecurrentEthernet2 VLAN6 priority
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.6.3Scalareth2VLAN6Addressread-writecurrentEthernet2 VLAN6 IP address
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.6.4Scalareth2VLAN6SubnetMaskread-writecurrentEthernet2 VLAN6 subnet mask
1.3.6.1.4.1.3052.18.2.4.1.1.2.5.6.5Scalareth2VLAN6Routerread-writecurrentEthernet2 VLAN6 router
1.3.6.1.4.1.3052.18.2.4.1.1.2.6Scalareth2MACread-onlycurrentEthernet2 MAC
1.3.6.1.4.1.3052.18.2.4.1.1.2.7Nodeeth2IPv6
1.3.6.1.4.1.3052.18.2.4.1.1.2.7.1Scalareth2IPv6Moderead-writecurrentControls IPv6 operation for this Ethernet interface.
1.3.6.1.4.1.3052.18.2.4.1.1.2.7.2Nodeeth2IPv6Static
1.3.6.1.4.1.3052.18.2.4.1.1.2.7.2.1Scalareth2IPv6StaticAddressread-writecurrenthe static IPv6 address to use for this interface when in operating in STATIC mode.
1.3.6.1.4.1.3052.18.2.4.1.1.2.7.2.2Scalareth2IPv6StaticRouterread-writecurrentThe IPv6 router to engage as the default router when this interface operates in STATIC mode.
1.3.6.1.4.1.3052.18.2.4.1.1.2.7.3Nodeeth2IPv6Auto
1.3.6.1.4.1.3052.18.2.4.1.1.2.7.3.1Scalareth2IPv6AutoAddress1read-onlycurrentOne of the automatically-acquired IPv6 addresses.
1.3.6.1.4.1.3052.18.2.4.1.1.2.7.3.2Scalareth2IPv6AutoAddress2read-onlycurrentOne of the automatically-acquired IPv6 addresses.
1.3.6.1.4.1.3052.18.2.4.1.1.2.7.3.3Scalareth2IPv6AutoAddress3read-onlycurrentOne of the automatically-acquired IPv6 addresses.
1.3.6.1.4.1.3052.18.2.4.1.1.2.7.3.4Scalareth2IPv6AutoAddress4read-onlycurrentOne of the automatically-acquired IPv6 addresses.
1.3.6.1.4.1.3052.18.2.4.1.1.2.7.4Scalareth2IPv6LinkLocalAddressread-onlycurrentThe link local IPv6 address for this interface. This is present when the IPv6 mode is not OFF.
1.3.6.1.4.1.3052.18.2.4.2ScalardefaultRouterread-writecurrentThe default router/gateway
1.3.6.1.4.1.3052.18.2.4.3TablednsTablenot-accessiblecurrentDNS server address table
1.3.6.1.4.1.3052.18.2.4.3.1RowdnsEntrynot-accessiblecurrentDNS server address entry
1.3.6.1.4.1.3052.18.2.4.3.1.1ColumndnsIndexread-onlycurrentIndex for DNS server address
1.3.6.1.4.1.3052.18.2.4.3.1.2ColumndnsAddressread-writecurrentDNS server address
1.3.6.1.4.1.3052.18.2.4.4Scalarhostnameread-writecurrentThe hostname of the unit
1.3.6.1.4.1.3052.18.2.4.5TablehostTablenot-accessiblecurrentStatic host table
1.3.6.1.4.1.3052.18.2.4.5.1RowhostEntrynot-accessiblecurrentStatic host entry
1.3.6.1.4.1.3052.18.2.4.5.1.1ColumnhostIndexread-onlycurrentIndex for static host
1.3.6.1.4.1.3052.18.2.4.5.1.2ColumnhostDeclarationread-writecurrentStatic host declaration string (i.e. 'address hostname')
1.3.6.1.4.1.3052.18.2.4.6ScalarncpDuplexread-writecurrentFor network command processor: 1=Input characters are echoed; 0=no echo.
1.3.6.1.4.1.3052.18.2.4.7ScalarncpTimeoutread-writecurrentNetwork command processor inactivity timeout
1.3.6.1.4.1.3052.18.2.4.8Nodesnmp
1.3.6.1.4.1.3052.18.2.4.8.1ScalarsnmpAgentEnableread-writecurrentON/OFF for snmp agent
1.3.6.1.4.1.3052.18.2.4.8.7NodesnmpNotificationTx
1.3.6.1.4.1.3052.18.2.4.8.7.1ScalarsnmpNtfnAttemptsread-writecurrentMaximum of times the unit attempts to send a notification (trap/inform) in 1 cycle
1.3.6.1.4.1.3052.18.2.4.8.7.2ScalarsnmpNtfnTimeoutread-writecurrentNumber of seconds between retries of sending a notification
1.3.6.1.4.1.3052.18.2.4.8.7.3ScalarsnmpNtfnCyclesread-writecurrentNumber of times the unit attempts a group of attempts to send a notification (a cycle)
1.3.6.1.4.1.3052.18.2.4.8.7.4ScalarsnmpNtfnSnoozeread-writecurrentMinutes between cycles
1.3.6.1.4.1.3052.18.2.4.8.8NodesnmpProxy
1.3.6.1.4.1.3052.18.2.4.8.8.1TablesnmpProxyTablenot-accessiblecurrentTable of SNMP proxy entries
1.3.6.1.4.1.3052.18.2.4.8.8.1.1RowsnmpProxyEntrynot-accessiblecurrentEntry for SNMP proxy table
1.3.6.1.4.1.3052.18.2.4.8.8.1.1.1ColumnsnmpProxyIndexread-onlycurrentIndex for SNMP proxy table
1.3.6.1.4.1.3052.18.2.4.8.8.1.1.2ColumnsnmpProxyEgressOIDBranchread-writecurrentThe OID branch to trigger the proxy function. This should cover the device to proxy. If blank then this proxy entry is disabled.
1.3.6.1.4.1.3052.18.2.4.8.8.1.1.3ColumnsnmpProxyIPread-writecurrentThe IP address of the device to proxy.
1.3.6.1.4.1.3052.18.2.4.8.8.1.1.4ColumnsnmpProxyPortread-writecurrentThe UDP port on which the device to proxy listens.
1.3.6.1.4.1.3052.18.2.4.8.8.1.1.5ColumnsnmpProxyIngressOIDBranchread-writecurrentThe OID branch to be remapped to egress OID branch to trigger the proxy function. If blank then the egress OID branch is proxied without remapping.
1.3.6.1.4.1.3052.18.2.4.8.8.1.1.6ColumnsnmpProxyNameread-writecurrentName of this proxy entry.
1.3.6.1.4.1.3052.18.2.4.8.9NodesnmpPoll
1.3.6.1.4.1.3052.18.2.4.8.9.1ScalarsnmpPModeread-writecurrentMode of poll operation: OFF or POLL ONLY (just make the results available to view).
1.3.6.1.4.1.3052.18.2.4.8.9.4TablesnmpPRequestTablenot-accessiblecurrentTable of SNMP Poll requests.
1.3.6.1.4.1.3052.18.2.4.8.9.4.1RowsnmpPRequestEntrynot-accessiblecurrentEntry for table pf SNMP Poll requests.
1.3.6.1.4.1.3052.18.2.4.8.9.4.1.1ColumnsnmpPRequestIndexread-onlycurrentIndex for table of SNMP Poll requests.
1.3.6.1.4.1.3052.18.2.4.8.9.4.1.2ColumnsnmpPRequestDescriptionread-writecurrentA description for this single telemetry request; no functional effect.
1.3.6.1.4.1.3052.18.2.4.8.9.4.1.3ColumnsnmpPRequestAgentread-writecurrentSNMP Agent IP address or hostname for this single telemetry request.
1.3.6.1.4.1.3052.18.2.4.8.9.4.1.4ColumnsnmpPRequestReadcomread-writecurrentSNMP read community for this single telemetry request.
1.3.6.1.4.1.3052.18.2.4.8.9.4.1.5ColumnsnmpPRequestOIDread-writecurrentSNMP object identifier for this single telemetry request.
1.3.6.1.4.1.3052.18.2.4.8.9.4.1.6ColumnsnmpPRequestPeriodread-writecurrentHow many seconds between periodic SNMP polls of this single telemetry request.
1.3.6.1.4.1.3052.18.2.4.8.9.4.1.10ColumnsnmpPRequestResultStatusread-onlycurrentStatus of the last attempt for this telemetry request.
1.3.6.1.4.1.3052.18.2.4.8.9.4.1.11ColumnsnmpPRequestResultValueread-onlycurrentThe telemetry value if the last request was successful.
1.3.6.1.4.1.3052.18.2.4.8.9.4.1.12ColumnsnmpPRequestResultTimeread-onlycurrentThe timestamp of the last telemetry request.
1.3.6.1.4.1.3052.18.2.4.8.9.4.1.13ColumnsnmpPRequestResultTyperead-onlycurrentThe type of the telemetry as reported by the agent.
1.3.6.1.4.1.3052.18.2.4.9NodeftpPush
1.3.6.1.4.1.3052.18.2.4.9.1ScalarftpPushEnableread-writecurrentEnable FTP push for REGULAR (protocol: FTP) or SECURE (protocol: SFTP) operation, or disable it (OFF)
1.3.6.1.4.1.3052.18.2.4.9.2ScalarftpPushServerread-writecurrentFTP server to which data should be pushed
1.3.6.1.4.1.3052.18.2.4.9.5ScalarftpPushAccountread-writecurrentFTP push account
1.3.6.1.4.1.3052.18.2.4.9.6ScalarftpPushDirectoryread-writecurrentFTP push directory
1.3.6.1.4.1.3052.18.2.4.9.7ScalarftpPushperiodread-writecurrentMinutes between pushes
1.3.6.1.4.1.3052.18.2.4.9.8TableftpPushPushFileTablenot-accessiblecurrentTable of files to push
1.3.6.1.4.1.3052.18.2.4.9.8.1RowftpPushPushFileEntrynot-accessiblecurrentEntry for table of files to push
1.3.6.1.4.1.3052.18.2.4.9.8.1.1ColumnftpPushPushFileIndexread-onlycurrentIndex for table of files to push
1.3.6.1.4.1.3052.18.2.4.9.8.1.2ColumnftpPushPushFileread-writecurrentON/OFF push this local FILEx
1.3.6.1.4.1.3052.18.2.4.9.9ScalarftpPushPushAuditread-writecurrentON/OFF push the audit log
1.3.6.1.4.1.3052.18.2.4.9.10ScalarftpPushPushAlarmsread-writecurrentON/OFF push the alarms/events file
1.3.6.1.4.1.3052.18.2.4.9.11TableftpPushRemoteFileTablenot-accessiblecurrentTable of remote names of files to push
1.3.6.1.4.1.3052.18.2.4.9.11.1RowftpPushRemoteFileEntrynot-accessiblecurrentEntry for table of remote names of files to push
1.3.6.1.4.1.3052.18.2.4.9.11.1.1ColumnftpPushRemoteFileIndexread-onlycurrentIndex for table of remote names of files to push
1.3.6.1.4.1.3052.18.2.4.9.11.1.2ColumnftpPushRemoteFileNameread-writecurrentremote name of pushed FILEx (name on server)
1.3.6.1.4.1.3052.18.2.4.9.12ScalarftpPushRemoteAlarmNameread-writecurrentFilename on server for alarms
1.3.6.1.4.1.3052.18.2.4.9.13ScalarftpPushPassiveread-writecurrentON/OFF use ftp passive mode
1.3.6.1.4.1.3052.18.2.4.9.14ScalarftpPushIncludeDateread-writecurrentON/OFF include the date in the name of the pushed file
1.3.6.1.4.1.3052.18.2.4.9.15ScalarftpPushIncludeTimeread-writecurrentON/OFF include the time in the name of the pushed file
1.3.6.1.4.1.3052.18.2.4.9.16ScalarftpPushIncludeSeqread-writecurrentON/OFF include a sequence number in the name of the pushed file
1.3.6.1.4.1.3052.18.2.4.9.17ScalarftpPushPermissionsread-writecurrentUnix permissions to apply to pushed files (octal notation).
1.3.6.1.4.1.3052.18.2.4.11Noderouting
1.3.6.1.4.1.3052.18.2.4.11.2ScalarethRoutingEnableread-writecurrentON/OFF unit routes IP traffic from Ethernet to PPP/Wireless
1.3.6.1.4.1.3052.18.2.4.11.3ScalarethRoutingNATEnableread-writecurrentON/OFF unit applies NAT on routed IP frames egressing the unit on its PPP interface
1.3.6.1.4.1.3052.18.2.4.12NodenetSecurity
1.3.6.1.4.1.3052.18.2.4.12.1NodeipRestriction
1.3.6.1.4.1.3052.18.2.4.12.1.1TableipRestrictionTablenot-accessiblecurrentTable of IP restrictions
1.3.6.1.4.1.3052.18.2.4.12.1.1.1RowipRestrictionEntrynot-accessiblecurrentEntry for table of IP restrictions
1.3.6.1.4.1.3052.18.2.4.12.1.1.1.1ColumnipRestrictionIndexread-onlycurrentIndex for table of IP restrictions
1.3.6.1.4.1.3052.18.2.4.12.1.1.1.2ColumnipRestrictionEnableread-writecurrentON/OFF enable this IP restriction
1.3.6.1.4.1.3052.18.2.4.12.1.1.1.3ColumnipRestrictionMaskread-writecurrentIP restriction mask
1.3.6.1.4.1.3052.18.2.4.14Nodetrap
1.3.6.1.4.1.3052.18.2.4.14.1NodetrapInclude
1.3.6.1.4.1.3052.18.2.4.14.1.1ScalartrapIncludeDateTimeread-writecurrentON/OFF include date and time in stock trap message
1.3.6.1.4.1.3052.18.2.4.14.1.2ScalartrapIncludeSiteNameread-writecurrentON/OFF include site name in stock trap message
1.3.6.1.4.1.3052.18.2.4.14.1.3ScalartrapIncludeSensorIDread-writecurrentON/OFF include sensor ID in stock trap message
1.3.6.1.4.1.3052.18.2.4.14.1.4ScalartrapIncludeUDNameread-writecurrentON/OFF include user defined name in stock trap message
1.3.6.1.4.1.3052.18.2.4.14.1.5ScalartrapIncludeUDStateread-writecurrentON/OFF include user defined state in stock trap message
1.3.6.1.4.1.3052.18.2.4.14.1.6ScalartrapIncludeSourceAddressread-writecurrentON/OFF include source IP address in stock trap message
1.3.6.1.4.1.3052.18.2.4.14.2ScalartrapAuthFailEnableread-writecurrentON/OFF enable trap sent upon SNMP authentication failure
1.3.6.1.4.1.3052.18.2.4.16Nodewireless
1.3.6.1.4.1.3052.18.2.4.16.1ScalarwirelessModeread-writecurrentWireless mode (OFF,PERMANENT-EDGE)
1.3.6.1.4.1.3052.18.2.4.16.2ScalarwirelessAPNread-writecurrentWireless access point name
1.3.6.1.4.1.3052.18.2.4.16.3ScalarwirelessIdleTimeoutread-writecurrentWireless idle timeout
1.3.6.1.4.1.3052.18.2.4.16.5ScalarwirelessPINread-writecurrentWireless modem SIM PIN
1.3.6.1.4.1.3052.18.2.4.16.9ScalarwirelessDREread-writecurrentDefault route enable for wireless network interface. When this is ON, the wireless link, if up, becomes the default route, overriding the default route setting…
1.3.6.1.4.1.3052.18.2.4.16.10ScalarwirelessPPPUsernameread-writecurrentUsername for PPP-based wireless modem connections.
1.3.6.1.4.1.3052.18.2.4.16.11ScalarwirelessFirewallread-writecurrentEnable wireless modem firewall.
1.3.6.1.4.1.3052.18.2.4.16.12ScalarwirelessKeepaliveThresholdread-writecurrentMinutes of no RX activity before sending keep-alive.
1.3.6.1.4.1.3052.18.2.4.16.13ScalarwirelessPPPDebugread-writecurrentEnable wireless modem PPP debug.
1.3.6.1.4.1.3052.18.2.4.16.20NodewirelessConnectivity
1.3.6.1.4.1.3052.18.2.4.16.20.1ScalarwirelessConnEnableread-writecurrentEnable wireless modem connectivity check.
1.3.6.1.4.1.3052.18.2.4.16.20.2ScalarwirelessConnCheckIntervalread-writecurrentWireless connectivity check interval in minutes.
1.3.6.1.4.1.3052.18.2.4.16.20.3ScalarwirelessConnFailThresholdread-writecurrentWireless connectivity fail threshold.
1.3.6.1.4.1.3052.18.2.4.16.20.10ScalarwirelessConnIP1read-writecurrentWireless connectivity check IP address 1.
1.3.6.1.4.1.3052.18.2.4.16.20.11ScalarwirelessConnIP2read-writecurrentWireless connectivity check IP address 2.
1.3.6.1.4.1.3052.18.2.4.17Nodeemail
1.3.6.1.4.1.3052.18.2.4.17.1ScalaremailServerread-writecurrentSMTP server to which the unit sends email
1.3.6.1.4.1.3052.18.2.4.17.2ScalaremailDomainread-writecurrentDomain to use in recipient address
1.3.6.1.4.1.3052.18.2.4.17.3ScalaremailAuthEnableread-writecurrentON/OFF enable SMTP authentication
1.3.6.1.4.1.3052.18.2.4.18NodenetAdvanced
1.3.6.1.4.1.3052.18.2.4.18.1ScalararpFilterread-writecurrentARP filter code
1.3.6.1.4.1.3052.18.2.4.19Nodeweb
1.3.6.1.4.1.3052.18.2.4.19.1ScalarwebEnableread-writecurrentON/OFF for the web interface
1.3.6.1.4.1.3052.18.2.4.19.2ScalarwebPortread-writecurrentTCP port on which web interface listens
1.3.6.1.4.1.3052.18.2.4.19.3ScalarwebTimeoutread-writecurrentWeb interface session timeout (seconds)
1.3.6.1.4.1.3052.18.2.4.21Nodeipv6
1.3.6.1.4.1.3052.18.2.4.21.1Scalaripv6DefaultRouterread-writecurrentThe IPv6 default router in use.
1.3.6.1.4.1.3052.18.2.4.22Nodecpe
1.3.6.1.4.1.3052.18.2.4.22.1TablecpeTablenot-accessiblecurrentTable of CPEs
1.3.6.1.4.1.3052.18.2.4.22.1.1RowcpeEntrynot-accessiblecurrentEntry for table of CPEs
1.3.6.1.4.1.3052.18.2.4.22.1.1.1ColumncpeIndexread-onlycurrentIndex for table of CPEs
1.3.6.1.4.1.3052.18.2.4.22.1.1.2ColumncpeHostread-writecurrentCPE host (IP address or DNS name)
1.3.6.1.4.1.3052.18.2.4.22.1.1.3ColumncpeNameread-writecurrentCPE name, informational only
1.3.6.1.4.1.3052.18.2.4.22.1.1.4ColumncpeDescriptionread-writecurrentCPE description, informational only
1.3.6.1.4.1.3052.18.2.4.22.1.1.5ColumncpeKeepaliveread-writecurrentNumber of seconds between each successful ping request.
1.3.6.1.4.1.3052.18.2.4.22.1.1.6ColumncpeThresholdread-writecurrentNumber of unsuccessful pings that triggers the CPE event.
1.3.6.1.4.1.3052.18.2.4.22.1.1.7ColumncpeEventReminderIntervalread-writecurrentCPE event reminder interval (minutes).
1.3.6.1.4.1.3052.18.2.4.22.1.1.20ColumncpeKeepaliveTicksread-writecurrentCPE ping period in 16ths of a second (nonzero overrides keepalive).
1.3.6.1.4.1.3052.18.2.4.22.1.1.21ColumncpePingSizeread-writecurrentNumber of bytes in CPE ping payload
1.3.6.1.4.1.3052.18.2.4.22.1.1.30ColumncpeInfoResetread-writecurrentSet any number to reset CPE ping stats.
1.3.6.1.4.1.3052.18.2.4.22.1.1.31ColumncpeInfoNumReqread-onlycurrentTotal number of requests transmitted.
1.3.6.1.4.1.3052.18.2.4.22.1.1.32ColumncpeInfoNumGoodRespread-onlycurrentTotal number of non-corrupt responses.
1.3.6.1.4.1.3052.18.2.4.22.1.1.33ColumncpeInfoNumBadRespread-onlycurrentTotal number of corrupt responses.
1.3.6.1.4.1.3052.18.2.4.22.1.1.34ColumncpeInfoNumLostRespread-onlycurrentTotal number of requests with no response.
1.3.6.1.4.1.3052.18.2.4.22.1.1.35ColumncpeInfoPercentLossread-onlycurrentPercent loss (missing responses / total requests).
1.3.6.1.4.1.3052.18.2.4.22.1.1.36ColumncpeInfoPercentBadread-onlycurrentPercent corrupt (corrupt responses / total requests).
1.3.6.1.4.1.3052.18.2.8Nodetime
1.3.6.1.4.1.3052.18.2.8.1Scalarclockread-writecurrentText string for date and time; e.g. 'SUN 01/02/98 12:34:27'. When setting this object, only the date and time are required; the unit will ignore a specified da…
1.3.6.1.4.1.3052.18.2.10Nodeconsole
1.3.6.1.4.1.3052.18.2.10.1ScalarconsoleDuplexread-writecurrentON/OFF characters echoed on telnet command session
1.3.6.1.4.1.3052.18.2.10.2ScalarconsoleTimeoutread-writecurrentMinutes of inactivity after which telnet command session is terminated
1.3.6.1.4.1.3052.18.2.10.7ScalarconsoleConfirmread-writecurrentON/OFF Prompt to confirm certain actions
1.3.6.1.4.1.3052.18.2.11NodeunitSecurity
1.3.6.1.4.1.3052.18.2.11.1NodesecCore
1.3.6.1.4.1.3052.18.2.11.1.1ScalarscShowPasswordPromptread-writecurrentON/OFF show password prompt upon login
1.3.6.1.4.1.3052.18.2.11.1.2ScalarscConsoleLoginRequiredread-writecurrentON/OFF login required upon connecting via console
1.3.6.1.4.1.3052.18.2.11.1.7ScalarscAuthModeread-writecurrentAuthentication mode (USERNAME/PW,PW/USERNAME,PASSWORD ONLY)
1.3.6.1.4.1.3052.18.2.11.1.8ScalarscRightsGroupread-writecurrentThe set of aliases used for the 8 available rights levels
1.3.6.1.4.1.3052.18.2.11.1.9ScalarscSecretread-writecurrentShared secret for challenges
1.3.6.1.4.1.3052.18.2.11.2TablesecUserTablenot-accessiblecurrentTable of users
1.3.6.1.4.1.3052.18.2.11.2.1RowsecUserEntrynot-accessiblecurrentEntry for table of users
1.3.6.1.4.1.3052.18.2.11.2.1.1ColumnsecUserIndexread-onlycurrentIndex for table of users
1.3.6.1.4.1.3052.18.2.11.2.1.2ColumnsecUserEnableread-writecurrentON/OFF enable user
1.3.6.1.4.1.3052.18.2.11.2.1.5ColumnsecUserConnectViaread-writecurrentMethods by which user is allowed to connect: L=local (console) T=Telnet F=FTP Ss=SSH W=Web
1.3.6.1.4.1.3052.18.2.11.2.1.6ColumnsecUserLoginToread-writecurrentThe function presented to the user upon login (COMMAND, PASSTHROUGH,MENU)
1.3.6.1.4.1.3052.18.2.11.2.1.7ColumnsecUserAccessFileread-writecurrentThe default access file associated with the user
1.3.6.1.4.1.3052.18.2.11.2.1.9ColumnsecUserPTEscapeToread-writecurrentThe function presented to the user upon escaping pass- through: currently only MENU
1.3.6.1.4.1.3052.18.2.11.2.1.11ColumnsecUserRightsread-writecurrentThe rights level granted to this user
1.3.6.1.4.1.3052.18.2.11.2.1.13ColumnsecUserEventsReadAccessread-writecurrentDENY/ALLOW user to read the events/alarms file
1.3.6.1.4.1.3052.18.2.11.2.1.14ColumnsecUserAuditReadAccessread-writecurrentDENY/ALLOW user to read the audit log
1.3.6.1.4.1.3052.18.2.11.2.1.16ColumnsecUserEventsWriteAccessread-writecurrentDENY/ALLOW user to delete the events file
1.3.6.1.4.1.3052.18.2.11.2.1.17ColumnsecUserAuditWriteAccessread-writecurrentDENY/ALLOW user to write to the audit log
1.3.6.1.4.1.3052.18.2.11.2.1.18ColumnsecUserExpirationread-writecurrentExpiration date/time of this user
1.3.6.1.4.1.3052.18.2.11.2.1.24ColumnsecUserChallengeConsoleModeread-writecurrentConsole challenge mode: when user logs in via console, unit allows access (OFF), or presents a challenge (CHALLENGE)
1.3.6.1.4.1.3052.18.2.11.2.1.27ColumnsecUserChallengeExpirationread-writecurrentTime (in minutes) after which a one-time-password is sent that it can be used to log in
1.3.6.1.4.1.3052.18.2.11.3NodesecFactory
1.3.6.1.4.1.3052.18.2.11.3.1ScalarsfEnableread-writecurrentON/OFF enable factory access
1.3.6.1.4.1.3052.18.2.11.3.2ScalarsfSecretread-writecurrentSecret used for factory access
1.3.6.1.4.1.3052.18.2.12Nodeevent
1.3.6.1.4.1.3052.18.2.12.1NodeevCore
1.3.6.1.4.1.3052.18.2.12.1.1TableevClassNameTablenot-accessiblecurrentTable of classes
1.3.6.1.4.1.3052.18.2.12.1.1.1RowevClassNameEntrynot-accessiblecurrentEntry for table of classes
1.3.6.1.4.1.3052.18.2.12.1.1.1.1ColumnevClassNameIndexread-onlycurrentIndex for table of classes
1.3.6.1.4.1.3052.18.2.12.1.1.1.2ColumnevClassNameread-writecurrentClass name for this slot
1.3.6.1.4.1.3052.18.2.12.1.2ScalarevReminderIntervalread-writecurrentInterval (minutes) between EventSensor reminder events
1.3.6.1.4.1.3052.18.2.12.1.3NodeevLog
1.3.6.1.4.1.3052.18.2.12.1.3.1ScalarevLogEnableread-writecurrentON/OFF enable event log
1.3.6.1.4.1.3052.18.2.12.1.3.2ScalarevLogStoreAlarmread-writecurrentON/OFF store data alarms in event log
1.3.6.1.4.1.3052.18.2.12.1.3.3ScalarevLogMaxSizeread-writecurrentmax size (in KB) of event log
1.3.6.1.4.1.3052.18.2.12.1.3.4ScalarevLogStoreSensorread-writecurrentON/OFF store EventSensor events in event log
1.3.6.1.4.1.3052.18.2.12.1.3.5ScalarevLogTimeStampAlarmsread-writecurrentON/OFF put timestamps on event log entries
1.3.6.1.4.1.3052.18.2.12.1.3.6ScalarevLogPrependNameread-writecurrentON/OFF prepend data event name to data alarm records in event log
1.3.6.1.4.1.3052.18.2.12.1.4NodeevMgmt
1.3.6.1.4.1.3052.18.2.12.1.4.3ScalarevMgmtReprocessread-writecurrentNumber of sensors that have generated events since reset. Write this to reprocess each sensor's last generated event since reset. The value to write determines…
1.3.6.1.4.1.3052.18.2.12.5NodeevSched1
1.3.6.1.4.1.3052.18.2.12.5.1ScalarevSched1Enableread-writecurrentON/OFF enable this scheduled event
1.3.6.1.4.1.3052.18.2.12.5.2ScalarevSched1Actionsread-writecurrentActions for this scheduled event
1.3.6.1.4.1.3052.18.2.12.5.3ScalarevSched1Messageread-writecurrentMessage for this scheduled event
1.3.6.1.4.1.3052.18.2.12.5.4ScalarevSched1TrapNumread-writecurrentTrap number for this scheduled event
1.3.6.1.4.1.3052.18.2.12.5.5ScalarevSched1Classread-writecurrentClass for this scheduled event
1.3.6.1.4.1.3052.18.2.12.5.6ScalarevSched1Sundayread-writecurrentTime on Sunday (HH:MM) when this scheduled event triggers
1.3.6.1.4.1.3052.18.2.12.5.7ScalarevSched1Mondayread-writecurrentTime on Monday (HH:MM) when this scheduled event triggers
1.3.6.1.4.1.3052.18.2.12.5.8ScalarevSched1Tuesdayread-writecurrentTime on Tuesday (HH:MM) when this scheduled event triggers
1.3.6.1.4.1.3052.18.2.12.5.9ScalarevSched1Wednesdayread-writecurrentTime on Wednesday (HH:MM) when this scheduled event triggers
1.3.6.1.4.1.3052.18.2.12.5.10ScalarevSched1Thursdayread-writecurrentTime on Thursday (HH:MM) when this scheduled event triggers
1.3.6.1.4.1.3052.18.2.12.5.11ScalarevSched1Fridayread-writecurrentTime on Friday (HH:MM) when this scheduled event triggers
1.3.6.1.4.1.3052.18.2.12.5.12ScalarevSched1Saturdayread-writecurrentTime on Saturday (HH:MM) when this scheduled event triggers
1.3.6.1.4.1.3052.18.2.12.5.13ScalarevSched1Exclusionsread-writecurrentExclusions (space-separated MM/DD-formatted dates) for this scheduled event
1.3.6.1.4.1.3052.18.2.12.6NodeevSched2
1.3.6.1.4.1.3052.18.2.12.6.1ScalarevSched2Enableread-writecurrentON/OFF enable this scheduled event
1.3.6.1.4.1.3052.18.2.12.6.2ScalarevSched2Actionsread-writecurrentActions for this scheduled event
1.3.6.1.4.1.3052.18.2.12.6.3ScalarevSched2Messageread-writecurrentMessage for this scheduled event
1.3.6.1.4.1.3052.18.2.12.6.4ScalarevSched2TrapNumread-writecurrentTrap number for this scheduled event
1.3.6.1.4.1.3052.18.2.12.6.5ScalarevSched2Classread-writecurrentClass for this scheduled event
1.3.6.1.4.1.3052.18.2.12.6.6ScalarevSched2Sundayread-writecurrentTime on Sunday (HH:MM) when this scheduled event triggers
1.3.6.1.4.1.3052.18.2.12.6.7ScalarevSched2Mondayread-writecurrentTime on Monday (HH:MM) when this scheduled event triggers
1.3.6.1.4.1.3052.18.2.12.6.8ScalarevSched2Tuesdayread-writecurrentTime on Tuesday (HH:MM) when this scheduled event triggers
1.3.6.1.4.1.3052.18.2.12.6.9ScalarevSched2Wednesdayread-writecurrentTime on Wednesday (HH:MM) when this scheduled event triggers
1.3.6.1.4.1.3052.18.2.12.6.10ScalarevSched2Thursdayread-writecurrentTime on Thursday (HH:MM) when this scheduled event triggers
1.3.6.1.4.1.3052.18.2.12.6.11ScalarevSched2Fridayread-writecurrentTime on Friday (HH:MM) when this scheduled event triggers
1.3.6.1.4.1.3052.18.2.12.6.12ScalarevSched2Saturdayread-writecurrentTime on Saturday (HH:MM) when this scheduled event triggers
1.3.6.1.4.1.3052.18.2.12.6.13ScalarevSched2Exclusionsread-writecurrentExclusions (space-separated MM/DD-formatted dates) for this scheduled event
1.3.6.1.4.1.3052.18.2.12.7TableevShskLowTablenot-accessiblecurrentTable of serial handshaking low events
1.3.6.1.4.1.3052.18.2.12.7.1RowevShskLowEntrynot-accessiblecurrentEntry for table of serial handshaking low events
1.3.6.1.4.1.3052.18.2.12.7.1.1ColumnevShskLowIndexread-onlycurrentIndex for table of serial handshaking low events
1.3.6.1.4.1.3052.18.2.12.7.1.2ColumnevShskLowEnableread-writecurrentON/OFF: enable the serial handshaking low event for this port
1.3.6.1.4.1.3052.18.2.12.7.1.3ColumnevShskLowActionsread-writecurrentActions for the serial handshaking low event for this port
1.3.6.1.4.1.3052.18.2.12.7.1.4ColumnevShskLowMessageread-writecurrentMessage for the serial handshaking low event for this port
1.3.6.1.4.1.3052.18.2.12.7.1.5ColumnevShskLowClassread-writecurrentClass for the serial handshaking low event for this port
1.3.6.1.4.1.3052.18.2.12.7.1.6ColumnevShskLowTrapNumread-writecurrentTrap number for the serial handshaking low event for this port
1.3.6.1.4.1.3052.18.2.12.8TableevShskHighTablenot-accessiblecurrentTable of serial handshaking high events
1.3.6.1.4.1.3052.18.2.12.8.1RowevShskHighEntrynot-accessiblecurrentEntry for table of serial handshaking high events
1.3.6.1.4.1.3052.18.2.12.8.1.1ColumnevShskHighIndexread-onlycurrentIndex for table of serial handshaking high events
1.3.6.1.4.1.3052.18.2.12.8.1.2ColumnevShskHighEnableread-writecurrentON/OFF: enable the serial handshaking high event for this port
1.3.6.1.4.1.3052.18.2.12.8.1.3ColumnevShskHighActionsread-writecurrentActions for the serial handshaking high event for this port
1.3.6.1.4.1.3052.18.2.12.8.1.4ColumnevShskHighMessageread-writecurrentMessage for the serial handshaking high event for this port
1.3.6.1.4.1.3052.18.2.12.8.1.5ColumnevShskHighClassread-writecurrentClass for the serial handshaking high event for this port
1.3.6.1.4.1.3052.18.2.12.8.1.6ColumnevShskHighTrapNumread-writecurrentTrap number for the serial handshaking high event for this port
1.3.6.1.4.1.3052.18.2.12.9NodeevNoSensor
1.3.6.1.4.1.3052.18.2.12.9.1ScalarevNoSensorTimeoutread-writecurrentTimeout (seconds) after which an EventSensor becomes unresponsive that this event is triggered
1.3.6.1.4.1.3052.18.2.12.9.2ScalarevNoSensorActionsread-writecurrentActions for no sensor event
1.3.6.1.4.1.3052.18.2.12.9.3ScalarevNoSensorTrapNumread-writecurrentTrap number for no sensor event
1.3.6.1.4.1.3052.18.2.12.9.4ScalarevNoSensorClassread-writecurrentClass for no sensor event
1.3.6.1.4.1.3052.18.2.12.11NodefuelSensor
1.3.6.1.4.1.3052.18.2.12.11.1TablefuelSensorGeneralTablenot-accessiblecurrentThis table organizes general fuel sensor attributes.
1.3.6.1.4.1.3052.18.2.12.11.1.1RowfsGenEntrynot-accessiblecurrentEntry for fuel sensor general config table.
1.3.6.1.4.1.3052.18.2.12.11.1.1.1ColumnfsGenIndexread-onlycurrentWhich fuel sensor in the fuel sensor general config table.
1.3.6.1.4.1.3052.18.2.12.11.1.1.2ColumnfsGenNameread-writecurrentFuel sensor name.
1.3.6.1.4.1.3052.18.2.12.11.1.1.3ColumnfsGenSensorTyperead-writecurrentType of fuel sensor in use; NONE disables the fuel sensor.
1.3.6.1.4.1.3052.18.2.12.11.1.1.4ColumnfsGenDistanceUnitread-writecurrentDistance units in use when setting and indicating tank dimensions.
1.3.6.1.4.1.3052.18.2.12.11.1.1.5ColumnfsGenRawValueTopread-writecurrentAnalog input reading corresponding to the SENSOR FULL point.
1.3.6.1.4.1.3052.18.2.12.11.1.1.6ColumnfsGenTopOffsetread-writecurrentDistance, in the specified distance unit, between the SENSOR FULL point and the TANK FULL point. The value is positive if the SENSOR FULL point is above the TA…
1.3.6.1.4.1.3052.18.2.12.11.1.1.7ColumnfsGenRawValueBottomread-writecurrentAnalog input reading corresponding to the minimum fluid height measurable by the fuel sensor.
1.3.6.1.4.1.3052.18.2.12.11.1.1.8ColumnfsGenBottomOffsetread-writecurrentDistance, in the specified distance unit, between the SENSOR EMPTY point and the TANK EMPTY point. The value is positive if the SENSOR EMPTY point is above the…
1.3.6.1.4.1.3052.18.2.12.11.1.1.9ColumnfsGenInputESread-writecurrentWhich eventsensor contains the analog input associated with this fuel sensor. Allowed values are 200 (for internal ES), or 1-16.
1.3.6.1.4.1.3052.18.2.12.11.1.1.10ColumnfsGenInputPointread-writecurrentWhich analog input point, on the specified eventsensor, that is associated with the fuel sensor.
1.3.6.1.4.1.3052.18.2.12.11.1.1.11ColumnfsGenFilterAveragingread-writecurrentFuel sensor filter averaging factor.
1.3.6.1.4.1.3052.18.2.12.11.1.1.12ColumnfsGenSysrepEnableread-writecurrentFuel sensor System Reporting enable.
1.3.6.1.4.1.3052.18.2.12.11.1.1.13ColumnfsGenSysrepThresholdread-writecurrentFuel sensor System Reporting threshold (floating point value).
1.3.6.1.4.1.3052.18.2.12.11.1.1.14ColumnfsGenSysrepLimitread-writecurrentFuel sensor System Reporting limit.
1.3.6.1.4.1.3052.18.2.12.11.1.1.15ColumnfsGenSysrepPackageread-writecurrentFuel sensor System Reporting package number.
1.3.6.1.4.1.3052.18.2.12.11.1.1.16ColumnfsGenSysrepTyperead-writecurrentFuel sensor ASM profile type.
1.3.6.1.4.1.3052.18.2.12.11.1.1.17ColumnfsGenEnableread-writecurrentFuel sensor enable.
1.3.6.1.4.1.3052.18.2.12.11.2TablefuelSensorTankTablenot-accessiblecurrentThis table organizes tank-specific fuel sensor attributes.
1.3.6.1.4.1.3052.18.2.12.11.2.1RowfsTankEntrynot-accessiblecurrentEntry for fuel sensor tank config table.
1.3.6.1.4.1.3052.18.2.12.11.2.1.1ColumnfsTankIndexread-onlycurrentWhich fuel sensor in the fuel sensor tank config table.
1.3.6.1.4.1.3052.18.2.12.11.2.1.2ColumnfsTankHeightread-writecurrentHeight of the tank, from the TANK EMPTY point to the TANK FULL point, in the specified distance unit (i.e. TANK HEIGHT). This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.11.2.1.3ColumnfsTankDimAread-writecurrentTank dimension measurement A for certain tank profiles. For HORIZ OVAL, this is the length of the straight section. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.11.2.1.4ColumnfsTankDimBread-writecurrentTank dimension measurement B for certain tank profiles. For HORIZ OVAL, this is the radius of the curved section. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.11.2.1.5ColumnfsTankVolumeread-writecurrentHow many volume units the tank contains, when full. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.11.2.1.6ColumnfsTankVolumeUnitread-writecurrentName of the unit representing fluid volume in the tank. This is only used for display purposes; it does not affect the volume calculation.
1.3.6.1.4.1.3052.18.2.12.11.2.1.7ColumnfsTankShaperead-writecurrentThe shape of the fuel tank. A value of LINEAR produces a fluid volume reading that is directly proportional to fluid height. The HORIZ CYL and HORIZ OVAL setti…
1.3.6.1.4.1.3052.18.2.12.11.3TablefuelSensorCustomTankTablenot-accessiblecurrentThis table organizes the custom tank strapping table. Each fuel sensor has a table of height/volume pairs in service only when the tank shape (fsTankShape) in …
1.3.6.1.4.1.3052.18.2.12.11.3.1RowfsCustomTankEntrynot-accessiblecurrentEntry for fuel sensor custom tank config table.
1.3.6.1.4.1.3052.18.2.12.11.3.1.1ColumnfsCustomTankIndexFSread-onlycurrentWhich fuel sensor in the fuel sensor tank config table. This is the first of two indexes for this SNMP table.
1.3.6.1.4.1.3052.18.2.12.11.3.1.2ColumnfsCustomTankIndexDatumread-onlycurrentWhich hight/volume pair: there are 32 pairs per fuel sensor. This is the second of two indexes for this SNMP table.
1.3.6.1.4.1.3052.18.2.12.11.3.1.3ColumnfsCustomTankHeightread-writecurrentHeight of custom tank height/volume pair. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.11.3.1.4ColumnfsCustomTankVolumeread-writecurrentVolume of custom tank height/volume pair. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.11.4TablefuelSensorVolumeTablenot-accessiblecurrentThis table organizes volume-event-specific fuel sensor attributes.
1.3.6.1.4.1.3052.18.2.12.11.4.1RowfsVolumeEntrynot-accessiblecurrentEntry for fuel sensor volume event config table.
1.3.6.1.4.1.3052.18.2.12.11.4.1.1ColumnfsVolumeIndexread-onlycurrentWhich fuel sensor in the fuel sensor volume event config table.
1.3.6.1.4.1.3052.18.2.12.11.4.1.2ColumnfsVolumeEnableread-writecurrentEnable fuel sensor volume events.
1.3.6.1.4.1.3052.18.2.12.11.4.1.3ColumnfsVolumeDeadbandread-writecurrentFuel sensor deadband (hysteresis). This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.11.4.1.4ColumnfsVolumeVHighValueread-writecurrentFuel sensor volume very high event threshold value. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.11.4.1.5ColumnfsVolumeVHighActionsread-writecurrentFuel sensor volume very high event threshold actions.
1.3.6.1.4.1.3052.18.2.12.11.4.1.6ColumnfsVolumeVHighTrapNumread-writecurrentFuel sensor volume very high event threshold trap number.
1.3.6.1.4.1.3052.18.2.12.11.4.1.7ColumnfsVolumeVHighClassread-writecurrentFuel sensor volume very high event threshold class (severity).
1.3.6.1.4.1.3052.18.2.12.11.4.1.8ColumnfsVolumeHighValueread-writecurrentFuel sensor volume high event threshold value. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.11.4.1.9ColumnfsVolumeHighActionsread-writecurrentFuel sensor volume high event threshold actions.
1.3.6.1.4.1.3052.18.2.12.11.4.1.10ColumnfsVolumeHighTrapNumread-writecurrentFuel sensor volume high event threshold trap number.
1.3.6.1.4.1.3052.18.2.12.11.4.1.11ColumnfsVolumeHighClassread-writecurrentFuel sensor volume high event threshold class (severity).
1.3.6.1.4.1.3052.18.2.12.11.4.1.12ColumnfsVolumeNormalActionsread-writecurrentFuel sensor volume return to normal actions.
1.3.6.1.4.1.3052.18.2.12.11.4.1.13ColumnfsVolumeNormalTrapNumread-writecurrentFuel sensor volume return to normal trap number.
1.3.6.1.4.1.3052.18.2.12.11.4.1.14ColumnfsVolumeNormalClassread-writecurrentFuel sensor volume return to normal class (severity).
1.3.6.1.4.1.3052.18.2.12.11.4.1.15ColumnfsVolumeLowValueread-writecurrentFuel sensor volume low event threshold value. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.11.4.1.16ColumnfsVolumeLowActionsread-writecurrentFuel sensor volume low event threshold actions.
1.3.6.1.4.1.3052.18.2.12.11.4.1.17ColumnfsVolumeLowTrapNumread-writecurrentFuel sensor volume low event threshold trap number.
1.3.6.1.4.1.3052.18.2.12.11.4.1.18ColumnfsVolumeLowClassread-writecurrentFuel sensor volume low event threshold class (severity).
1.3.6.1.4.1.3052.18.2.12.11.4.1.19ColumnfsVolumeVLowValueread-writecurrentFuel sensor volume very low event threshold value. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.11.4.1.20ColumnfsVolumeVLowActionsread-writecurrentFuel sensor volume very low event threshold actions.
1.3.6.1.4.1.3052.18.2.12.11.4.1.21ColumnfsVolumeVLowTrapNumread-writecurrentFuel sensor volume very low event threshold trap number.
1.3.6.1.4.1.3052.18.2.12.11.4.1.22ColumnfsVolumeVLowClassread-writecurrentFuel sensor volume very low event threshold class (severity).
1.3.6.1.4.1.3052.18.2.12.11.5TablefuelSensorDisconnectTablenot-accessiblecurrentThis table organizes disconnect-event-specific fuel sensor attributes.
1.3.6.1.4.1.3052.18.2.12.11.5.1RowfsDiscEntrynot-accessiblecurrentEntry for fuel sensor disconnect event config table.
1.3.6.1.4.1.3052.18.2.12.11.5.1.1ColumnfsDiscIndexread-onlycurrentWhich fuel sensor in the fuel sensor disconnect event config table.
1.3.6.1.4.1.3052.18.2.12.11.5.1.2ColumnfsDiscEnableread-writecurrentFuel sensor disconnect event enable.
1.3.6.1.4.1.3052.18.2.12.11.5.1.3ColumnfsDiscHighValueread-writecurrentHigh end of input value range when fuel sensor is disconnected. This is in the units of the analog input value.
1.3.6.1.4.1.3052.18.2.12.11.5.1.4ColumnfsDiscLowValueread-writecurrentLow end of input value range when fuel sensor is disconnected. This is in the units of the analog input value.
1.3.6.1.4.1.3052.18.2.12.11.5.1.5ColumnfsDiscActionsread-writecurrentFuel sensor disconnect event actions.
1.3.6.1.4.1.3052.18.2.12.11.5.1.6ColumnfsDiscTrapNumread-writecurrentFuel sensor disconnect event trap number.
1.3.6.1.4.1.3052.18.2.12.11.5.1.7ColumnfsDiscClassread-writecurrentFuel sensor disconnect event class (severity).
1.3.6.1.4.1.3052.18.2.12.11.5.1.8ColumnfsDiscNormalActionsread-writecurrentFuel sensor disconnect return to normal actions.
1.3.6.1.4.1.3052.18.2.12.11.5.1.9ColumnfsDiscNormalTrapNumread-writecurrentFuel sensor disconnect return to normal trap number.
1.3.6.1.4.1.3052.18.2.12.11.5.1.10ColumnfsDiscNormalClassread-writecurrentFuel sensor disconnect return to normal class (severity).
1.3.6.1.4.1.3052.18.2.12.11.6TablefuelSensorSuddenChangeTablenot-accessiblecurrentThis table organizes sudden-change-event-specific fuel sensor attributes.
1.3.6.1.4.1.3052.18.2.12.11.6.1RowfsSuddenChangeEntrynot-accessiblecurrentEntry for fuel sensor sudden change event config table.
1.3.6.1.4.1.3052.18.2.12.11.6.1.1ColumnfsSuddenChangeIndexread-onlycurrentWhich fuel sensor in the fuel sensor sudden change event config table.
1.3.6.1.4.1.3052.18.2.12.11.6.1.2ColumnfsSuddenChangeEnableread-writecurrentFuel volume sudden change event enable.
1.3.6.1.4.1.3052.18.2.12.11.6.1.3ColumnfsSuddenChangeTimeread-writecurrentFuel volume sudden change event time (minutes): what duration defines 'sudden'.
1.3.6.1.4.1.3052.18.2.12.11.6.1.4ColumnfsSuddenChangeAmplituderead-writecurrentFuel volume sudden change event amplitude: what amount (in fuel volume units) over the duration (fsSuddenChangeTime) defines enough change.
1.3.6.1.4.1.3052.18.2.12.11.6.1.5ColumnfsSuddenChangeActionsread-writecurrentFuel volume sudden change event actions.
1.3.6.1.4.1.3052.18.2.12.11.6.1.6ColumnfsSuddenChangeTrapNumread-writecurrentFuel volume sudden change event trap number.
1.3.6.1.4.1.3052.18.2.12.11.6.1.7ColumnfsSuddenChangeClassread-writecurrentFuel volume sudden change event class (severity).
1.3.6.1.4.1.3052.18.2.12.11.7TablefuelSensorSlowChangeTablenot-accessiblecurrentThis table organizes slow-change-event-specific fuel sensor attributes.
1.3.6.1.4.1.3052.18.2.12.11.7.1RowfsSlowChangeEntrynot-accessiblecurrentEntry for fuel sensor slow change event config table.
1.3.6.1.4.1.3052.18.2.12.11.7.1.1ColumnfsSlowChangeIndexread-onlycurrentWhich fuel sensor in the fuel sensor slow change event config table.
1.3.6.1.4.1.3052.18.2.12.11.7.1.2ColumnfsSlowChangeEnableread-writecurrentFuel volume slow change event enable.
1.3.6.1.4.1.3052.18.2.12.11.7.1.3ColumnfsSlowChangeTimeread-writecurrentFuel volume slow change event time (minutes): what duration defines 'slow'.
1.3.6.1.4.1.3052.18.2.12.11.7.1.4ColumnfsSlowChangeAmplituderead-writecurrentFuel volume slow change event amplitude: what amount (in fuel volume units) over the duration (fsSlowChangeTime) defines enough change.
1.3.6.1.4.1.3052.18.2.12.11.7.1.5ColumnfsSlowChangeActionsread-writecurrentFuel volume slow change event actions.
1.3.6.1.4.1.3052.18.2.12.11.7.1.6ColumnfsSlowChangeTrapNumread-writecurrentFuel volume slow change event trap number.
1.3.6.1.4.1.3052.18.2.12.11.7.1.7ColumnfsSlowChangeClassread-writecurrentFuel volume slow change event class (severity).
1.3.6.1.4.1.3052.18.2.12.11.8TablefuelSensorLevelsAutoAdjustTablenot-accessiblecurrentThis table organizes fuel sensor attributes for levels auto-adjustment.
1.3.6.1.4.1.3052.18.2.12.11.8.1RowfsLAAEntrynot-accessiblecurrentEntry for fuel sensor levels auto-adjust config table.
1.3.6.1.4.1.3052.18.2.12.11.8.1.1ColumnfsLAAIndexread-onlycurrentWhich fuel sensor in the fuel sensor levels auto-adjust config table.
1.3.6.1.4.1.3052.18.2.12.11.8.1.2ColumnfsLAAEnableread-writecurrentEnable fuel sensor levels auto-adjustment.
1.3.6.1.4.1.3052.18.2.12.11.8.1.3ColumnfsLAAEventEnableread-writecurrentEnable fuel sensor levels auto-adjust event.
1.3.6.1.4.1.3052.18.2.12.11.8.1.4ColumnfsLAAEventThresholdread-writecurrentSets level auto-adjust event threshold as percentage of raw value top value. In other words, the event is triggered if the cumulative auto-adjustment, as a per…
1.3.6.1.4.1.3052.18.2.12.11.8.1.5ColumnfsLAAEventActionsread-writecurrentActions for fuel sensor levels auto-adjust event.
1.3.6.1.4.1.3052.18.2.12.11.8.1.6ColumnfsLAAEventClassread-writecurrentClass for fuel sensor levels auto-adjust event.
1.3.6.1.4.1.3052.18.2.12.11.8.1.7ColumnfsLAAEventTrapNumread-writecurrentTrap number for fuel sensor levels auto-adjust event.
1.3.6.1.4.1.3052.18.2.12.12NodeacPowerMonitor
1.3.6.1.4.1.3052.18.2.12.12.1TableacpmGeneralTablenot-accessiblecurrentThis table organizes general AC power monitor attributes.
1.3.6.1.4.1.3052.18.2.12.12.1.1RowacpmGenEntrynot-accessiblecurrentEntry for AC power monitor general config table.
1.3.6.1.4.1.3052.18.2.12.12.1.1.1ColumnacpmGenIndexread-onlycurrentWhich AC power monitor in the AC power monitor general config table.
1.3.6.1.4.1.3052.18.2.12.12.1.1.2ColumnacpmGenDeviceread-writecurrentModel of the AC power monitor device. The unit needs this setting to know which registers to poll for the various data items, among other things.
1.3.6.1.4.1.3052.18.2.12.12.1.1.3ColumnacpmGenNameread-writecurrentName for the AC power monitor device.
1.3.6.1.4.1.3052.18.2.12.12.1.1.4ColumnacpmGenAddressread-writecurrentModbus address of the AC power monitor device.
1.3.6.1.4.1.3052.18.2.12.12.1.1.5ColumnacpmGenPtRatioread-writecurrentRatio of secondary turns to primary turns on potential transformers (PT).
1.3.6.1.4.1.3052.18.2.12.12.1.1.6ColumnacpmGenCtRatioread-writecurrentRatio of secondary turns to primary turns on current transformers (CT).
1.3.6.1.4.1.3052.18.2.12.12.1.1.7ColumnacpmGenPowerTyperead-writecurrentType of power being monitored.
1.3.6.1.4.1.3052.18.2.12.12.1.1.8ColumnacpmGenSysrepPackageread-writecurrentSystem reporting package number.
1.3.6.1.4.1.3052.18.2.12.12.1.1.9ColumnacpmGenSysrepTyperead-writecurrentASM profile type.
1.3.6.1.4.1.3052.18.2.12.12.1.1.10ColumnacpmGenEnableread-writecurrentAC power monitor enable.
1.3.6.1.4.1.3052.18.2.12.12.2TableacpmAvgVoltageTablenot-accessiblecurrentThis table organizes AC power monitor average voltage attributes.
1.3.6.1.4.1.3052.18.2.12.12.2.1RowacpmAvgVoltageEntrynot-accessiblecurrentEntry for AC power monitor average voltage config table.
1.3.6.1.4.1.3052.18.2.12.12.2.1.1ColumnacpmAvgVoltageIndexread-onlycurrentWhich AC power monitor in the AC power monitor average voltage config table.
1.3.6.1.4.1.3052.18.2.12.12.2.1.2ColumnacpmAvgVoltageEnableread-writecurrentEnable AC power monitor average voltage events.
1.3.6.1.4.1.3052.18.2.12.12.2.1.3ColumnacpmAvgVoltageDeadbandread-writecurrentDeadband (hysteresis) for average voltage event. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.12.2.1.4ColumnacpmAvgVoltageVHighValueread-writecurrentVery high event threshold. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.12.2.1.5ColumnacpmAvgVoltageVHighActionsread-writecurrentVery high event actions.
1.3.6.1.4.1.3052.18.2.12.12.2.1.6ColumnacpmAvgVoltageVHighTrapNumread-writecurrentVery high event trap number.
1.3.6.1.4.1.3052.18.2.12.12.2.1.7ColumnacpmAvgVoltageVHighClassread-writecurrentVery high event class.
1.3.6.1.4.1.3052.18.2.12.12.2.1.8ColumnacpmAvgVoltageHighValueread-writecurrentHigh event threshold. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.12.2.1.9ColumnacpmAvgVoltageHighActionsread-writecurrentHigh event actions.
1.3.6.1.4.1.3052.18.2.12.12.2.1.10ColumnacpmAvgVoltageHighTrapNumread-writecurrentHigh event trap number.
1.3.6.1.4.1.3052.18.2.12.12.2.1.11ColumnacpmAvgVoltageHighClassread-writecurrentHigh event class.
1.3.6.1.4.1.3052.18.2.12.12.2.1.12ColumnacpmAvgVoltageNormalActionsread-writecurrentReturn to normal actions.
1.3.6.1.4.1.3052.18.2.12.12.2.1.13ColumnacpmAvgVoltageNormalTrapNumread-writecurrentReturn to normal trap number.
1.3.6.1.4.1.3052.18.2.12.12.2.1.14ColumnacpmAvgVoltageNormalClassread-writecurrentReturn to normal class.
1.3.6.1.4.1.3052.18.2.12.12.2.1.15ColumnacpmAvgVoltageLowValueread-writecurrentLow event threshold. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.12.2.1.16ColumnacpmAvgVoltageLowActionsread-writecurrentLow event actions.
1.3.6.1.4.1.3052.18.2.12.12.2.1.17ColumnacpmAvgVoltageLowTrapNumread-writecurrentLow event trap number.
1.3.6.1.4.1.3052.18.2.12.12.2.1.18ColumnacpmAvgVoltageLowClassread-writecurrentLow event class.
1.3.6.1.4.1.3052.18.2.12.12.2.1.19ColumnacpmAvgVoltageVLowValueread-writecurrentVery low event threshold. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.12.2.1.20ColumnacpmAvgVoltageVLowActionsread-writecurrentVery low event actions.
1.3.6.1.4.1.3052.18.2.12.12.2.1.21ColumnacpmAvgVoltageVLowTrapNumread-writecurrentVery low event trap number.
1.3.6.1.4.1.3052.18.2.12.12.2.1.22ColumnacpmAvgVoltageVLowClassread-writecurrentVery low event class.
1.3.6.1.4.1.3052.18.2.12.12.2.1.23ColumnacpmAvgVoltageSysrepEnableread-writecurrentSystem reporting enable for average voltage telemetry.
1.3.6.1.4.1.3052.18.2.12.12.2.1.24ColumnacpmAvgVoltageSysrepThresholdread-writecurrentSystem reporting threshold for average voltage telemetry. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.12.2.1.25ColumnacpmAvgVoltageSysrepLimitread-writecurrentSystem reporting limit for average voltage telemetry.
1.3.6.1.4.1.3052.18.2.12.12.3TableacpmAvgCurrentTablenot-accessiblecurrentThis table organizes AC power monitor average current attributes.
1.3.6.1.4.1.3052.18.2.12.12.3.1RowacpmAvgCurrentEntrynot-accessiblecurrentEntry for AC power monitor average current config table.
1.3.6.1.4.1.3052.18.2.12.12.3.1.1ColumnacpmAvgCurrentIndexread-onlycurrentWhich AC power monitor in the AC power monitor average current config table.
1.3.6.1.4.1.3052.18.2.12.12.3.1.2ColumnacpmAvgCurrentEnableread-writecurrentEnable AC power monitor average current events.
1.3.6.1.4.1.3052.18.2.12.12.3.1.3ColumnacpmAvgCurrentDeadbandread-writecurrentDeadband (hysteresis) for average current event. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.12.3.1.4ColumnacpmAvgCurrentVHighValueread-writecurrentVery high event threshold. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.12.3.1.5ColumnacpmAvgCurrentVHighActionsread-writecurrentVery high event actions.
1.3.6.1.4.1.3052.18.2.12.12.3.1.6ColumnacpmAvgCurrentVHighTrapNumread-writecurrentVery high event trap number.
1.3.6.1.4.1.3052.18.2.12.12.3.1.7ColumnacpmAvgCurrentVHighClassread-writecurrentVery high event class.
1.3.6.1.4.1.3052.18.2.12.12.3.1.8ColumnacpmAvgCurrentHighValueread-writecurrentHigh event threshold. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.12.3.1.9ColumnacpmAvgCurrentHighActionsread-writecurrentHigh event actions.
1.3.6.1.4.1.3052.18.2.12.12.3.1.10ColumnacpmAvgCurrentHighTrapNumread-writecurrentHigh event trap number.
1.3.6.1.4.1.3052.18.2.12.12.3.1.11ColumnacpmAvgCurrentHighClassread-writecurrentHigh event class.
1.3.6.1.4.1.3052.18.2.12.12.3.1.12ColumnacpmAvgCurrentNormalActionsread-writecurrentReturn to normal actions.
1.3.6.1.4.1.3052.18.2.12.12.3.1.13ColumnacpmAvgCurrentNormalTrapNumread-writecurrentReturn to normal trap number.
1.3.6.1.4.1.3052.18.2.12.12.3.1.14ColumnacpmAvgCurrentNormalClassread-writecurrentReturn to normal class.
1.3.6.1.4.1.3052.18.2.12.12.3.1.15ColumnacpmAvgCurrentLowValueread-writecurrentLow event threshold. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.12.3.1.16ColumnacpmAvgCurrentLowActionsread-writecurrentLow event actions.
1.3.6.1.4.1.3052.18.2.12.12.3.1.17ColumnacpmAvgCurrentLowTrapNumread-writecurrentLow event trap number.
1.3.6.1.4.1.3052.18.2.12.12.3.1.18ColumnacpmAvgCurrentLowClassread-writecurrentLow event class.
1.3.6.1.4.1.3052.18.2.12.12.3.1.19ColumnacpmAvgCurrentVLowValueread-writecurrentVery low event threshold. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.12.3.1.20ColumnacpmAvgCurrentVLowActionsread-writecurrentVery low event actions.
1.3.6.1.4.1.3052.18.2.12.12.3.1.21ColumnacpmAvgCurrentVLowTrapNumread-writecurrentVery low event trap number.
1.3.6.1.4.1.3052.18.2.12.12.3.1.22ColumnacpmAvgCurrentVLowClassread-writecurrentVery low event class.
1.3.6.1.4.1.3052.18.2.12.12.3.1.23ColumnacpmAvgCurrentSysrepEnableread-writecurrentSystem reporting enable for average current telemetry.
1.3.6.1.4.1.3052.18.2.12.12.3.1.24ColumnacpmAvgCurrentSysrepThresholdread-writecurrentSystem reporting threshold for average current telemetry. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.12.3.1.25ColumnacpmAvgCurrentSysrepLimitread-writecurrentSystem reporting limit for average current telemetry.
1.3.6.1.4.1.3052.18.2.12.12.4TableacpmFreqTablenot-accessiblecurrentThis table organizes AC power monitor frequency attributes.
1.3.6.1.4.1.3052.18.2.12.12.4.1RowacpmFreqEntrynot-accessiblecurrentEntry for AC power monitor frequency config table.
1.3.6.1.4.1.3052.18.2.12.12.4.1.1ColumnacpmFreqIndexread-onlycurrentWhich AC power monitor in the AC power monitor frequency config table.
1.3.6.1.4.1.3052.18.2.12.12.4.1.2ColumnacpmFreqEnableread-writecurrentEnable AC power monitor frequency events.
1.3.6.1.4.1.3052.18.2.12.12.4.1.3ColumnacpmFreqDeadbandread-writecurrentDeadband (hysteresis) for frequency event. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.12.4.1.4ColumnacpmFreqVHighValueread-writecurrentVery high event threshold. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.12.4.1.5ColumnacpmFreqVHighActionsread-writecurrentVery high event actions.
1.3.6.1.4.1.3052.18.2.12.12.4.1.6ColumnacpmFreqVHighTrapNumread-writecurrentVery high event trap number.
1.3.6.1.4.1.3052.18.2.12.12.4.1.7ColumnacpmFreqVHighClassread-writecurrentVery high event class.
1.3.6.1.4.1.3052.18.2.12.12.4.1.8ColumnacpmFreqHighValueread-writecurrentHigh event threshold. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.12.4.1.9ColumnacpmFreqHighActionsread-writecurrentHigh event actions.
1.3.6.1.4.1.3052.18.2.12.12.4.1.10ColumnacpmFreqHighTrapNumread-writecurrentHigh event trap number.
1.3.6.1.4.1.3052.18.2.12.12.4.1.11ColumnacpmFreqHighClassread-writecurrentHigh event class.
1.3.6.1.4.1.3052.18.2.12.12.4.1.12ColumnacpmFreqNormalActionsread-writecurrentReturn to normal actions.
1.3.6.1.4.1.3052.18.2.12.12.4.1.13ColumnacpmFreqNormalTrapNumread-writecurrentReturn to normal trap number.
1.3.6.1.4.1.3052.18.2.12.12.4.1.14ColumnacpmFreqNormalClassread-writecurrentReturn to normal class.
1.3.6.1.4.1.3052.18.2.12.12.4.1.15ColumnacpmFreqLowValueread-writecurrentLow event threshold. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.12.4.1.16ColumnacpmFreqLowActionsread-writecurrentLow event actions.
1.3.6.1.4.1.3052.18.2.12.12.4.1.17ColumnacpmFreqLowTrapNumread-writecurrentLow event trap number.
1.3.6.1.4.1.3052.18.2.12.12.4.1.18ColumnacpmFreqLowClassread-writecurrentLow event class.
1.3.6.1.4.1.3052.18.2.12.12.4.1.19ColumnacpmFreqVLowValueread-writecurrentVery low event threshold. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.12.4.1.20ColumnacpmFreqVLowActionsread-writecurrentVery low event actions.
1.3.6.1.4.1.3052.18.2.12.12.4.1.21ColumnacpmFreqVLowTrapNumread-writecurrentVery low event trap number.
1.3.6.1.4.1.3052.18.2.12.12.4.1.22ColumnacpmFreqVLowClassread-writecurrentVery low event class.
1.3.6.1.4.1.3052.18.2.12.12.4.1.23ColumnacpmFreqSysrepEnableread-writecurrentSystem reporting enable for frequency telemetry.
1.3.6.1.4.1.3052.18.2.12.12.4.1.24ColumnacpmFreqSysrepThresholdread-writecurrentSystem reporting threshold for frequency telemetry. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.12.4.1.25ColumnacpmFreqSysrepLimitread-writecurrentSystem reporting limit for frequency telemetry.
1.3.6.1.4.1.3052.18.2.12.12.5TableacpmTotalRealPowerTablenot-accessiblecurrentThis table organizes AC power monitor total real power attributes.
1.3.6.1.4.1.3052.18.2.12.12.5.1RowacpmTRPEntrynot-accessiblecurrentEntry for AC power monitor total real power config table.
1.3.6.1.4.1.3052.18.2.12.12.5.1.1ColumnacpmTRPIndexread-onlycurrentWhich AC power monitor in the AC power monitor total real power config table.
1.3.6.1.4.1.3052.18.2.12.12.5.1.2ColumnacpmTRPEnableread-writecurrentEnable AC power monitor total real power events.
1.3.6.1.4.1.3052.18.2.12.12.5.1.3ColumnacpmTRPDeadbandread-writecurrentDeadband (hysteresis) for total real power event. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.12.5.1.4ColumnacpmTRPVHighValueread-writecurrentVery high event threshold. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.12.5.1.5ColumnacpmTRPVHighActionsread-writecurrentVery high event actions.
1.3.6.1.4.1.3052.18.2.12.12.5.1.6ColumnacpmTRPVHighTrapNumread-writecurrentVery high event trap number.
1.3.6.1.4.1.3052.18.2.12.12.5.1.7ColumnacpmTRPVHighClassread-writecurrentVery high event class.
1.3.6.1.4.1.3052.18.2.12.12.5.1.8ColumnacpmTRPHighValueread-writecurrentHigh event threshold. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.12.5.1.9ColumnacpmTRPHighActionsread-writecurrentHigh event actions.
1.3.6.1.4.1.3052.18.2.12.12.5.1.10ColumnacpmTRPHighTrapNumread-writecurrentHigh event trap number.
1.3.6.1.4.1.3052.18.2.12.12.5.1.11ColumnacpmTRPHighClassread-writecurrentHigh event class.
1.3.6.1.4.1.3052.18.2.12.12.5.1.12ColumnacpmTRPNormalActionsread-writecurrentReturn to normal actions.
1.3.6.1.4.1.3052.18.2.12.12.5.1.13ColumnacpmTRPNormalTrapNumread-writecurrentReturn to normal trap number.
1.3.6.1.4.1.3052.18.2.12.12.5.1.14ColumnacpmTRPNormalClassread-writecurrentReturn to normal class.
1.3.6.1.4.1.3052.18.2.12.12.5.1.15ColumnacpmTRPLowValueread-writecurrentLow event threshold. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.12.5.1.16ColumnacpmTRPLowActionsread-writecurrentLow event actions.
1.3.6.1.4.1.3052.18.2.12.12.5.1.17ColumnacpmTRPLowTrapNumread-writecurrentLow event trap number.
1.3.6.1.4.1.3052.18.2.12.12.5.1.18ColumnacpmTRPLowClassread-writecurrentLow event class.
1.3.6.1.4.1.3052.18.2.12.12.5.1.19ColumnacpmTRPVLowValueread-writecurrentVery low event threshold. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.12.5.1.20ColumnacpmTRPVLowActionsread-writecurrentVery low event actions.
1.3.6.1.4.1.3052.18.2.12.12.5.1.21ColumnacpmTRPVLowTrapNumread-writecurrentVery low event trap number.
1.3.6.1.4.1.3052.18.2.12.12.5.1.22ColumnacpmTRPVLowClassread-writecurrentVery low event class.
1.3.6.1.4.1.3052.18.2.12.12.5.1.23ColumnacpmTRPSysrepEnableread-writecurrentSystem reporting enable for total real power telemetry.
1.3.6.1.4.1.3052.18.2.12.12.5.1.24ColumnacpmTRPSysrepThresholdread-writecurrentSystem reporting threshold for total real power telemetry. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.12.5.1.25ColumnacpmTRPSysrepLimitread-writecurrentSystem reporting limit for total real power telemetry.
1.3.6.1.4.1.3052.18.2.12.12.6TableacpmDisconnectTablenot-accessiblecurrentThis table organizes AC power monitor device disconnect event attributes.
1.3.6.1.4.1.3052.18.2.12.12.6.1RowacpmDisconnectEntrynot-accessiblecurrentEntry for AC power monitor device disconnect event config table.
1.3.6.1.4.1.3052.18.2.12.12.6.1.1ColumnacpmDisconnectIndexread-onlycurrentWhich AC power monitor in the AC power monitor device disconnect event config table.
1.3.6.1.4.1.3052.18.2.12.12.6.1.2ColumnacpmDisconnectEnableread-writecurrentEnable AC power monitor device disconnect event.
1.3.6.1.4.1.3052.18.2.12.12.6.1.3ColumnacpmDisconnectActionsread-writecurrentActions for disconnect event.
1.3.6.1.4.1.3052.18.2.12.12.6.1.4ColumnacpmDisconnectTrapNumread-writecurrentTrap number for disconnect event.
1.3.6.1.4.1.3052.18.2.12.12.6.1.5ColumnacpmDisconnectClassread-writecurrentClass for disconnect event.
1.3.6.1.4.1.3052.18.2.12.12.6.1.6ColumnacpmDisconnectNormalActionsread-writecurrentActions for disconnect return to normal event.
1.3.6.1.4.1.3052.18.2.12.12.6.1.7ColumnacpmDisconnectNormalTrapNumread-writecurrentTrap number for disconnect return to normal event.
1.3.6.1.4.1.3052.18.2.12.12.6.1.8ColumnacpmDisconnectNormalClassread-writecurrentClass for disconnect return to normal event.
1.3.6.1.4.1.3052.18.2.12.12.7TableacpmTotalPowerFactorTablenot-accessiblecurrentThis table organizes AC power monitor device total power factor event attributes.
1.3.6.1.4.1.3052.18.2.12.12.7.1RowacpmTPFEntrynot-accessiblecurrentEntry for AC power monitor device total power factor event config table.
1.3.6.1.4.1.3052.18.2.12.12.7.1.1ColumnacpmTPFIndexread-onlycurrentWhich AC power monitor in the AC power monitor device disconnect event config table.
1.3.6.1.4.1.3052.18.2.12.12.7.1.2ColumnacpmTPFEnableread-writecurrentEnable AC power monitor device disconnect event.
1.3.6.1.4.1.3052.18.2.12.12.7.1.3ColumnacpmTPFDeadbandread-writecurrentDeadband (hysteresis).
1.3.6.1.4.1.3052.18.2.12.12.7.1.4ColumnacpmTPFNormalActionsread-writecurrentNormal actions.
1.3.6.1.4.1.3052.18.2.12.12.7.1.5ColumnacpmTPFNormalTrapNumread-writecurrentNormal trap number.
1.3.6.1.4.1.3052.18.2.12.12.7.1.6ColumnacpmTPFNormalClassread-writecurrentNormal class.
1.3.6.1.4.1.3052.18.2.12.12.7.1.7ColumnacpmTPFLowValueread-writecurrentLow threshold.
1.3.6.1.4.1.3052.18.2.12.12.7.1.8ColumnacpmTPFLowActionsread-writecurrentLow actions.
1.3.6.1.4.1.3052.18.2.12.12.7.1.9ColumnacpmTPFLowTrapNumread-writecurrentLow trap number.
1.3.6.1.4.1.3052.18.2.12.12.7.1.10ColumnacpmTPFLowClassread-writecurrentLow class.
1.3.6.1.4.1.3052.18.2.12.12.7.1.11ColumnacpmTPFVLowValueread-writecurrentVery Low threshold.
1.3.6.1.4.1.3052.18.2.12.12.7.1.12ColumnacpmTPFVLowActionsread-writecurrentVery Low actions.
1.3.6.1.4.1.3052.18.2.12.12.7.1.13ColumnacpmTPFVLowTrapNumread-writecurrentVery Low trap number.
1.3.6.1.4.1.3052.18.2.12.12.7.1.14ColumnacpmTPFVLowClassread-writecurrentVery Low class.
1.3.6.1.4.1.3052.18.2.12.12.7.1.15ColumnacpmTPFSysrepEnableread-writecurrentSystem reporting enable.
1.3.6.1.4.1.3052.18.2.12.12.7.1.16ColumnacpmTPFSysrepThresholdread-writecurrentSystem reporting threshold.
1.3.6.1.4.1.3052.18.2.12.12.7.1.17ColumnacpmTPFSysrepLimitread-writecurrentSystem reporting limit.
1.3.6.1.4.1.3052.18.2.12.14NodebatteryMonitor
1.3.6.1.4.1.3052.18.2.12.14.1TablebatteryMonitorGeneralTablenot-accessiblecurrentThis table organizes general battery monitor attributes.
1.3.6.1.4.1.3052.18.2.12.14.1.1RowbmGenEntrynot-accessiblecurrentEntry for battery monitor general config table.
1.3.6.1.4.1.3052.18.2.12.14.1.1.1ColumnbmGenIndexread-onlycurrentWhich battery monitor in the battery monitor general config table.
1.3.6.1.4.1.3052.18.2.12.14.1.1.2ColumnbmGenEnableread-writecurrentWhich battery monitor in the battery monitor general config table.
1.3.6.1.4.1.3052.18.2.12.14.1.1.3ColumnbmGenNameread-writecurrentName for this battery monitor.
1.3.6.1.4.1.3052.18.2.12.14.1.1.4ColumnbmGenBatteryQuantityread-writecurrentNumber of batteries in the string.
1.3.6.1.4.1.3052.18.2.12.14.1.1.5ColumnbmGenBatteryCapacityread-writecurrentCapacity of the individual batteries in the string, in amp-hours. A single value applies to all batteries; that is, they are assumed to be all of the same capa…
1.3.6.1.4.1.3052.18.2.12.14.1.1.6ColumnbmGenBatteryNominalVoltageread-writecurrentNominal voltage of the individual batteries in the string, in volts. A single value applies to all batteres; that is, they are assumed to be all of the same vo…
1.3.6.1.4.1.3052.18.2.12.14.1.1.7ColumnbmGenSysrepPackageread-writecurrentSystem reporting package number.
1.3.6.1.4.1.3052.18.2.12.14.1.1.8ColumnbmGenSysrepTyperead-writecurrentSystem reporting ASM profile type.
1.3.6.1.4.1.3052.18.2.12.14.2TablebatteryMonitorDeviceTablenot-accessiblecurrentThis table organizes temperature battery monitor attributes.
1.3.6.1.4.1.3052.18.2.12.14.2.1RowbmDeviceEntrynot-accessiblecurrentEntry for battery monitor temperature config table.
1.3.6.1.4.1.3052.18.2.12.14.2.1.1ColumnbmDeviceIndexread-onlycurrentWhich battery monitor in the battery monitor device config table.
1.3.6.1.4.1.3052.18.2.12.14.2.1.2ColumnbmDeviceTyperead-writecurrentThe type of hardware battery monitor unit associated with this battery monitor.
1.3.6.1.4.1.3052.18.2.12.14.2.1.3ColumnbmDeviceESread-writecurrentThe ES index of the hardware battery monitor unit associated with this battery monitor. This setting only pertains to the ES-BMU.
1.3.6.1.4.1.3052.18.2.12.14.2.1.4ColumnbmDeviceIPread-writecurrentThe IP address of the hardware battery monitor unit associated with this battery monitor.
1.3.6.1.4.1.3052.18.2.12.14.2.1.5ColumnbmDeviceReadcomread-writecurrentThe SNMP read community of the hardware battery monitor unit associated with this battery monitor.
1.3.6.1.4.1.3052.18.2.12.14.2.1.6ColumnbmDeviceInputStringread-writecurrentWhich string on the hardware battery monitor unit is associated with this battery monitor.
1.3.6.1.4.1.3052.18.2.12.14.2.1.7ColumnbmDeviceCTSizeread-writecurrentThe rating of the DC current sensor, in amperes. If this value is set to 0, then string current will not be measured. This setting only pertains to the ES-BMU.
1.3.6.1.4.1.3052.18.2.12.14.3TablebatteryMonitorTempTablenot-accessiblecurrentThis table organizes temperature battery monitor attributes.
1.3.6.1.4.1.3052.18.2.12.14.3.1RowbmTempEntrynot-accessiblecurrentEntry for battery monitor temperature config table.
1.3.6.1.4.1.3052.18.2.12.14.3.1.1ColumnbmTempIndexread-onlycurrentWhich battery monitor in the battery monitor temperature config table.
1.3.6.1.4.1.3052.18.2.12.14.3.1.2ColumnbmTempEnableread-writecurrentEnable/disable temperature event. This event is based on the average temperature of the jars in the string.
1.3.6.1.4.1.3052.18.2.12.14.3.1.3ColumnbmTempDeadbandread-writecurrentDeadband in degrees F or C, depending on scale setting of sensor referenced by bmGenDeviceES. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.14.3.1.4ColumnbmTempScaleread-writecurrentTemperature scale; this affects how temperature values are represented, and also how the temperature alarm thresholds and deadbands are interpreted.
1.3.6.1.4.1.3052.18.2.12.14.3.1.5ColumnbmTempHighValueread-writecurrentVery high event threshold in degrees F or C, depending on scale setting referenced by bmGenDeviceES. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.14.3.1.6ColumnbmTempHighActionsread-writecurrentActions for very high temperature event.
1.3.6.1.4.1.3052.18.2.12.14.3.1.7ColumnbmTempHighTrapNumread-writecurrentTrap number for high temperature event.
1.3.6.1.4.1.3052.18.2.12.14.3.1.8ColumnbmTempHighClassread-writecurrentClass for high temperature event.
1.3.6.1.4.1.3052.18.2.12.14.3.1.9ColumnbmTempNormalActionsread-writecurrentActions for return to normal temperature event.
1.3.6.1.4.1.3052.18.2.12.14.3.1.10ColumnbmTempNormalTrapNumread-writecurrentTrap number for return to normal temperature event.
1.3.6.1.4.1.3052.18.2.12.14.3.1.11ColumnbmTempNormalClassread-writecurrentClass for return to normal temperature event.
1.3.6.1.4.1.3052.18.2.12.14.3.1.12ColumnbmTempLowValueread-writecurrentLow event threshold in degrees F or C, depending on scale setting. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.14.3.1.13ColumnbmTempLowActionsread-writecurrentActions for low temperature event.
1.3.6.1.4.1.3052.18.2.12.14.3.1.14ColumnbmTempLowTrapNumread-writecurrentTrap number for low temperature event.
1.3.6.1.4.1.3052.18.2.12.14.3.1.15ColumnbmTempLowClassread-writecurrentTrap number for low temperature event.
1.3.6.1.4.1.3052.18.2.12.14.3.1.16ColumnbmTempSysrepEnableread-writecurrentSystem reporting enable for temperature telemetry.
1.3.6.1.4.1.3052.18.2.12.14.3.1.17ColumnbmTempSysrepThresholdread-writecurrentSystem reporting threshold for temperature telemetry. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.14.3.1.18ColumnbmTempSysrepLimitread-writecurrentSystem reporting limit for temperature telemetry.
1.3.6.1.4.1.3052.18.2.12.14.4TablebatteryMonitorDiffTempTablenot-accessiblecurrentThis table organizes differential temperature battery monitor attributes.
1.3.6.1.4.1.3052.18.2.12.14.4.1RowbmDiffTempEntrynot-accessiblecurrentEntry for battery monitor differential temperature config table.
1.3.6.1.4.1.3052.18.2.12.14.4.1.1ColumnbmDiffTempIndexread-onlycurrentWhich battery monitor in the battery monitor differential temperature config table.
1.3.6.1.4.1.3052.18.2.12.14.4.1.2ColumnbmDiffTempEnableread-writecurrentEnable/disable differential temperature event. This event is based on the differential between the average temperature of the batteries in the string, and ambi…
1.3.6.1.4.1.3052.18.2.12.14.4.1.3ColumnbmDiffTempDeadbandread-writecurrentDeadband in degrees F or C, depending on scale setting.
1.3.6.1.4.1.3052.18.2.12.14.4.1.4ColumnbmDiffTempVHighValueread-writecurrentVery high event threshold in degrees F or C, depending on scale setting.
1.3.6.1.4.1.3052.18.2.12.14.4.1.5ColumnbmDiffTempVHighActionsread-writecurrentActions for very high differential temperature event.
1.3.6.1.4.1.3052.18.2.12.14.4.1.6ColumnbmDiffTempVHighTrapNumread-writecurrentTrap number for very high differential temperature event.
1.3.6.1.4.1.3052.18.2.12.14.4.1.7ColumnbmDiffTempVHighClassread-writecurrentClass for very high differential temperature event.
1.3.6.1.4.1.3052.18.2.12.14.4.1.8ColumnbmDiffTempHighValueread-writecurrentHigh event threshold in degrees F or C, depending on scale setting.
1.3.6.1.4.1.3052.18.2.12.14.4.1.9ColumnbmDiffTempHighActionsread-writecurrentActions for high differential temperature event.
1.3.6.1.4.1.3052.18.2.12.14.4.1.10ColumnbmDiffTempHighTrapNumread-writecurrentTrap number for high differential temperature event.
1.3.6.1.4.1.3052.18.2.12.14.4.1.11ColumnbmDiffTempHighClassread-writecurrentClass for high differential temperature event.
1.3.6.1.4.1.3052.18.2.12.14.4.1.12ColumnbmDiffTempNormalActionsread-writecurrentActions for return to normal differential temperature event.
1.3.6.1.4.1.3052.18.2.12.14.4.1.13ColumnbmDiffTempNormalTrapNumread-writecurrentTrap number for return to normal differential temperature event.
1.3.6.1.4.1.3052.18.2.12.14.4.1.14ColumnbmDiffTempNormalClassread-writecurrentClass for return to normal differential temperature event.
1.3.6.1.4.1.3052.18.2.12.14.4.1.15ColumnbmDiffTempSysrepEnableread-writecurrentSystem reporting enable for differential temperature telemetry.
1.3.6.1.4.1.3052.18.2.12.14.4.1.16ColumnbmDiffTempSysrepThresholdread-writecurrentSystem reporting threshold for differential temperature telemetry.
1.3.6.1.4.1.3052.18.2.12.14.4.1.17ColumnbmDiffTempSysrepLimitread-writecurrentSystem reporting limit for differential temperature telemetry.
1.3.6.1.4.1.3052.18.2.12.14.5TablebatteryMonitorVoltageTablenot-accessiblecurrentThis table organizes battery monitor voltage attributes.
1.3.6.1.4.1.3052.18.2.12.14.5.1RowbmVoltageEntrynot-accessiblecurrentEntry for battery monitor voltage config table.
1.3.6.1.4.1.3052.18.2.12.14.5.1.1ColumnbmVoltageIndexread-onlycurrentWhich battery monitor in the battery monitor voltage config table.
1.3.6.1.4.1.3052.18.2.12.14.5.1.2ColumnbmVoltageEnableread-writecurrentEnable/disable voltage event. This event is based on the total voltage output of the batteries in the string.
1.3.6.1.4.1.3052.18.2.12.14.5.1.3ColumnbmVoltageDeadbandread-writecurrentDeadband in volts. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.14.5.1.4ColumnbmVoltageVHighValueread-writecurrentVery high event threshold, in volts. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.14.5.1.5ColumnbmVoltageVHighActionsread-writecurrentActions for very high voltage event.
1.3.6.1.4.1.3052.18.2.12.14.5.1.6ColumnbmVoltageVHighTrapNumread-writecurrentTrap number for very high voltage event.
1.3.6.1.4.1.3052.18.2.12.14.5.1.7ColumnbmVoltageVHighClassread-writecurrentClass for very high voltage event.
1.3.6.1.4.1.3052.18.2.12.14.5.1.8ColumnbmVoltageHighValueread-writecurrentHigh event threshold, in volts. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.14.5.1.9ColumnbmVoltageHighActionsread-writecurrentActions for high voltage event.
1.3.6.1.4.1.3052.18.2.12.14.5.1.10ColumnbmVoltageHighTrapNumread-writecurrentTrap number for high voltage event.
1.3.6.1.4.1.3052.18.2.12.14.5.1.11ColumnbmVoltageHighClassread-writecurrentClass for high voltage event.
1.3.6.1.4.1.3052.18.2.12.14.5.1.12ColumnbmVoltageNormalActionsread-writecurrentActions for return to normal voltage event.
1.3.6.1.4.1.3052.18.2.12.14.5.1.13ColumnbmVoltageNormalTrapNumread-writecurrentTrap number for return to normal voltage event.
1.3.6.1.4.1.3052.18.2.12.14.5.1.14ColumnbmVoltageNormalClassread-writecurrentClass for return to normal voltage event.
1.3.6.1.4.1.3052.18.2.12.14.5.1.15ColumnbmVoltageLowValueread-writecurrentLow event threshold, in volts. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.14.5.1.16ColumnbmVoltageLowActionsread-writecurrentActions for low voltage event.
1.3.6.1.4.1.3052.18.2.12.14.5.1.17ColumnbmVoltageLowTrapNumread-writecurrentTrap number for low voltage event.
1.3.6.1.4.1.3052.18.2.12.14.5.1.18ColumnbmVoltageLowClassread-writecurrentClass for low voltage event.
1.3.6.1.4.1.3052.18.2.12.14.5.1.19ColumnbmVoltageVLowValueread-writecurrentVery Low event threshold, in volts. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.14.5.1.20ColumnbmVoltageVLowActionsread-writecurrentActions for very low voltage event.
1.3.6.1.4.1.3052.18.2.12.14.5.1.21ColumnbmVoltageVLowTrapNumread-writecurrentTrap number for very low voltage event.
1.3.6.1.4.1.3052.18.2.12.14.5.1.22ColumnbmVoltageVLowClassread-writecurrentClass for very low voltage event.
1.3.6.1.4.1.3052.18.2.12.14.5.1.23ColumnbmVoltageSysrepEnableread-writecurrentSystem reporting enable for voltage telemetry.
1.3.6.1.4.1.3052.18.2.12.14.5.1.24ColumnbmVoltageSysrepThresholdread-writecurrentSystem reporting threshold for voltage telemetry. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.14.5.1.25ColumnbmVoltageSysrepLimitread-writecurrentSystem reporting limit for voltage telemetry.
1.3.6.1.4.1.3052.18.2.12.14.6TablebatteryMonitorDiffVoltTablenot-accessiblecurrentThis table organizes differential voltage battery monitor attributes.
1.3.6.1.4.1.3052.18.2.12.14.6.1RowbmDiffVoltEntrynot-accessiblecurrentEntry for battery monitor differential voltage config table.
1.3.6.1.4.1.3052.18.2.12.14.6.1.1ColumnbmDiffVoltIndexread-onlycurrentWhich battery monitor in the battery monitor differential voltage config table.
1.3.6.1.4.1.3052.18.2.12.14.6.1.2ColumnbmDiffVoltEnableread-writecurrentEnable/disable differential voltage event. This event is based on the differential between the highest and lowest jar voltages within the string.
1.3.6.1.4.1.3052.18.2.12.14.6.1.3ColumnbmDiffVoltDeadbandread-writecurrentDeadband in volts.
1.3.6.1.4.1.3052.18.2.12.14.6.1.4ColumnbmDiffVoltVHighValueread-writecurrentVery high event threshold in volts. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.14.6.1.5ColumnbmDiffVoltVHighActionsread-writecurrentActions for very high differential voltage event.
1.3.6.1.4.1.3052.18.2.12.14.6.1.6ColumnbmDiffVoltVHighTrapNumread-writecurrentTrap number for very high differential voltage event.
1.3.6.1.4.1.3052.18.2.12.14.6.1.7ColumnbmDiffVoltVHighClassread-writecurrentClass for very high differential voltage event.
1.3.6.1.4.1.3052.18.2.12.14.6.1.8ColumnbmDiffVoltHighValueread-writecurrentHigh event threshold in volts. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.14.6.1.9ColumnbmDiffVoltHighActionsread-writecurrentActions for high differential voltage event.
1.3.6.1.4.1.3052.18.2.12.14.6.1.10ColumnbmDiffVoltHighTrapNumread-writecurrentTrap number for high differential voltage event.
1.3.6.1.4.1.3052.18.2.12.14.6.1.11ColumnbmDiffVoltHighClassread-writecurrentClass for high differential voltage event.
1.3.6.1.4.1.3052.18.2.12.14.6.1.12ColumnbmDiffVoltNormalActionsread-writecurrentActions for return to normal differential voltage event.
1.3.6.1.4.1.3052.18.2.12.14.6.1.13ColumnbmDiffVoltNormalTrapNumread-writecurrentTrap number for return to normal differential voltage event.
1.3.6.1.4.1.3052.18.2.12.14.6.1.14ColumnbmDiffVoltNormalClassread-writecurrentClass for return to normal differential voltage event.
1.3.6.1.4.1.3052.18.2.12.14.6.1.15ColumnbmDiffVoltSysrepEnableread-writecurrentSystem reporting enable for differential voltage telemetry.
1.3.6.1.4.1.3052.18.2.12.14.6.1.16ColumnbmDiffVoltSysrepThresholdread-writecurrentSystem reporting threshold for differential voltage telemetry.
1.3.6.1.4.1.3052.18.2.12.14.6.1.17ColumnbmDiffVoltSysrepLimitread-writecurrentSystem reporting limit for differential voltage telemetry.
1.3.6.1.4.1.3052.18.2.12.14.7TablebatteryMonitorChargingCurrentTablenot-accessiblecurrentThis table organizes battery monitor charging current attributes.
1.3.6.1.4.1.3052.18.2.12.14.7.1RowbmChargingCurrentEntrynot-accessiblecurrentEntry for battery monitor differential charging current config table.
1.3.6.1.4.1.3052.18.2.12.14.7.1.1ColumnbmChargingCurrentIndexread-onlycurrentWhich battery monitor in the battery monitor charging current config table.
1.3.6.1.4.1.3052.18.2.12.14.7.1.2ColumnbmChargingCurrentEnableread-writecurrentEnable/disable charging current event. This event is based on positive current flow (i.e. current flowing into the battery string).
1.3.6.1.4.1.3052.18.2.12.14.7.1.3ColumnbmChargingCurrentDeadbandread-writecurrentDeadband in amperes. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.14.7.1.4ColumnbmChargingCurrentVHighValueread-writecurrentVery high event threshold, in volts. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.14.7.1.5ColumnbmChargingCurrentVHighActionsread-writecurrentActions for very high charging current event.
1.3.6.1.4.1.3052.18.2.12.14.7.1.6ColumnbmChargingCurrentVHighTrapNumread-writecurrentTrap number for very high charging current event.
1.3.6.1.4.1.3052.18.2.12.14.7.1.7ColumnbmChargingCurrentVHighClassread-writecurrentClass for very high charging current event.
1.3.6.1.4.1.3052.18.2.12.14.7.1.8ColumnbmChargingCurrentHighValueread-writecurrentHigh event threshold, in volts. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.14.7.1.9ColumnbmChargingCurrentHighActionsread-writecurrentActions for high charging current event.
1.3.6.1.4.1.3052.18.2.12.14.7.1.10ColumnbmChargingCurrentHighTrapNumread-writecurrentTrap number for high charging current event.
1.3.6.1.4.1.3052.18.2.12.14.7.1.11ColumnbmChargingCurrentHighClassread-writecurrentClass for high charging current event.
1.3.6.1.4.1.3052.18.2.12.14.7.1.12ColumnbmChargingCurrentNormalActionsread-writecurrentActions for return to normal charging current event.
1.3.6.1.4.1.3052.18.2.12.14.7.1.13ColumnbmChargingCurrentNormalTrapNumread-writecurrentTrap number for return to normal charging current event.
1.3.6.1.4.1.3052.18.2.12.14.7.1.14ColumnbmChargingCurrentNormalClassread-writecurrentClass for return to normal charging current event.
1.3.6.1.4.1.3052.18.2.12.14.7.1.15ColumnbmChargingCurrentSysrepEnableread-writecurrentSystem reporting enable for charging current telemetry.
1.3.6.1.4.1.3052.18.2.12.14.7.1.16ColumnbmChargingCurrentSysrepThresholdread-writecurrentSystem reporting threshold for charging current telemetry. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.14.7.1.17ColumnbmChargingCurrentSysrepLimitread-writecurrentSystem reporting limit for charging current telemetry.
1.3.6.1.4.1.3052.18.2.12.14.8TablebatteryMonitorDischargingCurrentTablenot-accessiblecurrentThis table organizes battery monitor discharging current attributes.
1.3.6.1.4.1.3052.18.2.12.14.8.1RowbmDischargingCurrentEntrynot-accessiblecurrentEntry for battery monitor differential discharging current config table.
1.3.6.1.4.1.3052.18.2.12.14.8.1.1ColumnbmDischargingCurrentIndexread-onlycurrentWhich battery monitor in the battery monitor discharging current config table.
1.3.6.1.4.1.3052.18.2.12.14.8.1.2ColumnbmDischargingCurrentEnableread-writecurrentEnable/disable discharging current event. This event is based on positive current flow (i.e. current flowing into the battery string).
1.3.6.1.4.1.3052.18.2.12.14.8.1.3ColumnbmDischargingCurrentDeadbandread-writecurrentDeadband in amperes. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.14.8.1.4ColumnbmDischargingCurrentVHighValueread-writecurrentVery high event threshold, in volts. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.14.8.1.5ColumnbmDischargingCurrentVHighActionsread-writecurrentActions for very high discharging current event.
1.3.6.1.4.1.3052.18.2.12.14.8.1.6ColumnbmDischargingCurrentVHighTrapNumread-writecurrentTrap number for very high discharging current event.
1.3.6.1.4.1.3052.18.2.12.14.8.1.7ColumnbmDischargingCurrentVHighClassread-writecurrentClass for very high discharging current event.
1.3.6.1.4.1.3052.18.2.12.14.8.1.8ColumnbmDischargingCurrentHighValueread-writecurrentHigh event threshold, in volts. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.14.8.1.9ColumnbmDischargingCurrentHighActionsread-writecurrentActions for high discharging current event.
1.3.6.1.4.1.3052.18.2.12.14.8.1.10ColumnbmDischargingCurrentHighTrapNumread-writecurrentTrap number for high discharging current event.
1.3.6.1.4.1.3052.18.2.12.14.8.1.11ColumnbmDischargingCurrentHighClassread-writecurrentClass for high discharging current event.
1.3.6.1.4.1.3052.18.2.12.14.8.1.12ColumnbmDischargingCurrentNormalActionsread-writecurrentActions for return to normal discharging current event.
1.3.6.1.4.1.3052.18.2.12.14.8.1.13ColumnbmDischargingCurrentNormalTrapNumread-writecurrentTrap number for return to normal discharging current event.
1.3.6.1.4.1.3052.18.2.12.14.8.1.14ColumnbmDischargingCurrentNormalClassread-writecurrentClass for return to normal discharging current event.
1.3.6.1.4.1.3052.18.2.12.14.8.1.15ColumnbmDischargingCurrentSysrepEnableread-writecurrentSystem reporting enable for discharging current telemetry.
1.3.6.1.4.1.3052.18.2.12.14.8.1.16ColumnbmDischargingCurrentSysrepThresholdread-writecurrentSystem reporting threshold for discharging current telemetry. This is a floating point value.
1.3.6.1.4.1.3052.18.2.12.14.8.1.17ColumnbmDischargingCurrentSysrepLimitread-writecurrentSystem reporting limit for discharging current telemetry.
1.3.6.1.4.1.3052.18.2.12.14.9TablebatteryMonitorChargeLevelTablenot-accessiblecurrentThis table organizes battery monitor charge level attributes.
1.3.6.1.4.1.3052.18.2.12.14.9.1RowbmChargeLevelEntrynot-accessiblecurrentEntry for battery monitor charge level config table.
1.3.6.1.4.1.3052.18.2.12.14.9.1.1ColumnbmChargeLevelIndexread-onlycurrentWhich battery monitor in the battery monitor charge level config table.
1.3.6.1.4.1.3052.18.2.12.14.9.1.2ColumnbmChargeLevelEnableread-writecurrentEnable/disable charge level event.
1.3.6.1.4.1.3052.18.2.12.14.9.1.3ColumnbmChargeLevelNormalActionsread-writecurrentActions for return to normal charge level event.
1.3.6.1.4.1.3052.18.2.12.14.9.1.4ColumnbmChargeLevelNormalTrapNumread-writecurrentTrap number for return to normal charge level event.
1.3.6.1.4.1.3052.18.2.12.14.9.1.5ColumnbmChargeLevelNormalClassread-writecurrentClass for return to normal charge level event.
1.3.6.1.4.1.3052.18.2.12.14.9.1.6ColumnbmChargeLevelLowActionsread-writecurrentActions for low charge level event.
1.3.6.1.4.1.3052.18.2.12.14.9.1.7ColumnbmChargeLevelLowTrapNumread-writecurrentTrap number for low charge level event.
1.3.6.1.4.1.3052.18.2.12.14.9.1.8ColumnbmChargeLevelLowClassread-writecurrentClass for low charge level event.
1.3.6.1.4.1.3052.18.2.12.14.9.1.9ColumnbmChargeLevelVLowActionsread-writecurrentActions for very low charge level event.
1.3.6.1.4.1.3052.18.2.12.14.9.1.10ColumnbmChargeLevelVLowTrapNumread-writecurrentTrap number for very low charge level event.
1.3.6.1.4.1.3052.18.2.12.14.9.1.11ColumnbmChargeLevelVLowClassread-writecurrentClass for very low charge level event.
1.3.6.1.4.1.3052.18.2.12.14.9.1.12ColumnbmChargeLevelSysrepEnableread-writecurrentSystem reporting enable for charge level telemetry.
1.3.6.1.4.1.3052.18.2.12.14.10TablebatteryMonitorJarHealthTablenot-accessiblecurrentThis table organizes battery monitor jar health attributes.
1.3.6.1.4.1.3052.18.2.12.14.10.1RowbmJarHealthEntrynot-accessiblecurrentEntry for battery monitor jar health config table.
1.3.6.1.4.1.3052.18.2.12.14.10.1.1ColumnbmJarHealthIndexread-onlycurrentWhich battery monitor in the battery monitor jar health config table.
1.3.6.1.4.1.3052.18.2.12.14.10.1.2ColumnbmJarHealthEnableread-writecurrentEnable/disable jar health event.
1.3.6.1.4.1.3052.18.2.12.14.10.1.3ColumnbmJarHealthNormalActionsread-writecurrentActions for return to normal jar health event.
1.3.6.1.4.1.3052.18.2.12.14.10.1.4ColumnbmJarHealthNormalTrapNumread-writecurrentTrap number for return to normal jar health event.
1.3.6.1.4.1.3052.18.2.12.14.10.1.5ColumnbmJarHealthNormalClassread-writecurrentClass for return to normal jar health event.
1.3.6.1.4.1.3052.18.2.12.14.10.1.6ColumnbmJarHealthLowActionsread-writecurrentActions for low jar health event.
1.3.6.1.4.1.3052.18.2.12.14.10.1.7ColumnbmJarHealthLowTrapNumread-writecurrentTrap number for low jar health event.
1.3.6.1.4.1.3052.18.2.12.14.10.1.8ColumnbmJarHealthLowClassread-writecurrentClass for low jar health event.
1.3.6.1.4.1.3052.18.2.12.14.10.1.9ColumnbmJarHealthVLowActionsread-writecurrentActions for very low jar health event.
1.3.6.1.4.1.3052.18.2.12.14.10.1.10ColumnbmJarHealthVLowTrapNumread-writecurrentTrap number for very low jar health event.
1.3.6.1.4.1.3052.18.2.12.14.10.1.11ColumnbmJarHealthVLowClassread-writecurrentClass for very low jar health event.
1.3.6.1.4.1.3052.18.2.12.14.10.1.12ColumnbmJarHealthSysrepEnableread-writecurrentSystem reporting enable for jar health telemetry.
1.3.6.1.4.1.3052.18.2.12.15NodeevLocation
1.3.6.1.4.1.3052.18.2.12.15.1ScalarevLocationEnableread-writecurrentEnable/disable location event. This event is triggered after the unit boots and gets a valid location fix from the GPS, or a timeout expires.
1.3.6.1.4.1.3052.18.2.12.15.2ScalarevLocationTimeoutread-writecurrentHow long the unit waits for valid location fix before giving up and generating location event anyhow.
1.3.6.1.4.1.3052.18.2.12.15.3ScalarevLocationActionsread-writecurrentActions for location event.
1.3.6.1.4.1.3052.18.2.12.15.4ScalarevLocationMsgSuccessread-writecurrentEvent message string that is used when location is successfully detected.
1.3.6.1.4.1.3052.18.2.12.15.5ScalarevLocationMsgFailread-writecurrentEvent message string that is used when location is cannot be detected.
1.3.6.1.4.1.3052.18.2.12.15.6ScalarevLocationIncludeLocationread-writecurrentEnable/disable appending the location information to the event message.
1.3.6.1.4.1.3052.18.2.12.15.7ScalarevLocationTrapnumread-writecurrentTrap number for the location event.
1.3.6.1.4.1.3052.18.2.12.15.8ScalarevLocationClassread-writecurrentClass for the location event.
1.3.6.1.4.1.3052.18.2.12.16NodeevReset
1.3.6.1.4.1.3052.18.2.12.16.1ScalarevResetEnableread-writecurrentEnable/disable reset event. This event is triggered when the unit finishes booting.
1.3.6.1.4.1.3052.18.2.12.16.2ScalarevResetDelayread-writecurrentNumber of seconds to wait after unit finishes booting before triggering the reset event.
1.3.6.1.4.1.3052.18.2.12.16.3ScalarevResetActionsread-writecurrentActions for reset event.
1.3.6.1.4.1.3052.18.2.12.16.4ScalarevResetMessageread-writecurrentMessage for reset event.
1.3.6.1.4.1.3052.18.2.12.16.5ScalarevResetTrapnumread-writecurrentTrap number for reset event.
1.3.6.1.4.1.3052.18.2.12.16.6ScalarevResetClassread-writecurrentClass (severity) for reset event.
1.3.6.1.4.1.3052.18.2.12.17NodeevSleep
1.3.6.1.4.1.3052.18.2.12.17.1ScalarevSleepEnableread-writecurrentEnable/disable sleep event. This event is triggered when the unit is imminently going to sleep.
1.3.6.1.4.1.3052.18.2.12.17.3ScalarevSleepActionsread-writecurrentActions for sleep event.
1.3.6.1.4.1.3052.18.2.12.17.4ScalarevSleepMessageread-writecurrentMessage for sleep event.
1.3.6.1.4.1.3052.18.2.12.17.5ScalarevSleepTrapnumread-writecurrentTrap number for sleep event.
1.3.6.1.4.1.3052.18.2.12.17.6ScalarevSleepClassread-writecurrentClass (severity) for sleep event.
1.3.6.1.4.1.3052.18.2.12.18NodeevGlobal
1.3.6.1.4.1.3052.18.2.12.18.2ScalarevGlobalActionsread-writecurrentGlobal event actions.
1.3.6.1.4.1.3052.18.2.12.18.3ScalarevGlobalTrapnumread-writecurrentGlobal trap number.
1.3.6.1.4.1.3052.18.2.12.21NodeaccessControl
1.3.6.1.4.1.3052.18.2.12.21.2ScalaracActionsread-writecurrentActions for the access control event.
1.3.6.1.4.1.3052.18.2.12.21.3ScalaracTrapnumread-writecurrentTrap number for the access control event.
1.3.6.1.4.1.3052.18.2.12.21.4ScalaracClassread-writecurrentClass (severity) for the access control event.
1.3.6.1.4.1.3052.18.2.12.21.10TableaccessControlDeviceTablenot-accessiblecurrentTable of access control devices for Access Control Device Management.
1.3.6.1.4.1.3052.18.2.12.21.10.1RowaccessControlDeviceEntrynot-accessiblecurrentEntry for table of access control devices for Access Control Device Management.
1.3.6.1.4.1.3052.18.2.12.21.10.1.1ColumnacdIndexread-onlycurrentIndex for table of access control devices for Access Control Device Management.
1.3.6.1.4.1.3052.18.2.12.21.10.1.2ColumnacdEnableread-writecurrentEnable management for this access control device.
1.3.6.1.4.1.3052.18.2.12.21.10.1.3ColumnacdNameread-writecurrentThe name of the access control device for informational purpose only.
1.3.6.1.4.1.3052.18.2.12.21.10.1.4ColumnacdReaderread-writecurrentThe kind of access control device.
1.3.6.1.4.1.3052.18.2.12.21.10.1.6ColumnacdWiegandESread-writecurrentIndex of the Wiegand interface hardware instance allocated as the access control device.
1.3.6.1.4.1.3052.18.2.12.21.10.1.7ColumnacdRelayTyperead-writecurrentType of relay which activates the door strike.
1.3.6.1.4.1.3052.18.2.12.21.10.1.8ColumnacdRelayESread-writecurrentWhich relay EventSensor is connected to the door strike.
1.3.6.1.4.1.3052.18.2.12.21.10.1.9ColumnacdRelayPointread-writecurrentWhich relay on the relay EventSensor is connected to the door strike.
1.3.6.1.4.1.3052.18.2.12.21.10.1.10ColumnacdOpenTimeread-writecurrent
1.3.6.1.4.1.3052.18.2.12.21.10.1.11ColumnacdUserGroupread-writecurrentUser group to which this access control device applies.
1.3.6.1.4.1.3052.18.2.12.21.11TableaccessControlUserTablenot-accessiblecurrentTable of access control users for Access Control Device Management.
1.3.6.1.4.1.3052.18.2.12.21.11.1RowaccessControlUserEntrynot-accessiblecurrentEntry for table of access control users for Access Control Device Management.
1.3.6.1.4.1.3052.18.2.12.21.11.1.1ColumnacuIndexUserGroupread-onlycurrentIndex for table of access control devices for Access Control Device Management which corresponds to the user group containing the user.
1.3.6.1.4.1.3052.18.2.12.21.11.1.2ColumnacuIndexUserread-onlycurrentIndex for table of access control devices for Access Control Device Management which corresponds to the user within the user group.
1.3.6.1.4.1.3052.18.2.12.21.11.1.3ColumnacuEnableread-writecurrentEnable this access control user.
1.3.6.1.4.1.3052.18.2.12.21.11.1.4ColumnacuNameread-writecurrentName for this access control user.
1.3.6.1.4.1.3052.18.2.12.21.11.1.5ColumnacuSnread-writecurrentSerial number of the card associated with the user.
1.3.6.1.4.1.3052.18.2.12.21.11.1.6ColumnacuSunBeginread-writecurrentTime of day (HH:MM) on Sundays when this user should be granted access.
1.3.6.1.4.1.3052.18.2.12.21.11.1.7ColumnacuSunEndread-writecurrentTime of day (HH:MM) on Sundays when this user should be forbidden access.
1.3.6.1.4.1.3052.18.2.12.21.11.1.8ColumnacuMonBeginread-writecurrentTime of day (HH:MM) on Mondays when this user should be granted access.
1.3.6.1.4.1.3052.18.2.12.21.11.1.9ColumnacuMonEndread-writecurrentTime of day (HH:MM) on Mondays when this user should be forbidden access.
1.3.6.1.4.1.3052.18.2.12.21.11.1.10ColumnacuTueBeginread-writecurrentTime of day (HH:MM) on Tuesdays when this user should be granted access.
1.3.6.1.4.1.3052.18.2.12.21.11.1.11ColumnacuTueEndread-writecurrentTime of day (HH:MM) on Tuesdays when this user should be forbidden access.
1.3.6.1.4.1.3052.18.2.12.21.11.1.12ColumnacuWedBeginread-writecurrentTime of day (HH:MM) on Wednesdays when this user should be granted access.
1.3.6.1.4.1.3052.18.2.12.21.11.1.13ColumnacuWedEndread-writecurrentTime of day (HH:MM) on Wednesdays when this user should be forbidden access.
1.3.6.1.4.1.3052.18.2.12.21.11.1.14ColumnacuThuBeginread-writecurrentTime of day (HH:MM) on Thursdays when this user should be granted access.
1.3.6.1.4.1.3052.18.2.12.21.11.1.15ColumnacuThuEndread-writecurrentTime of day (HH:MM) on Thursdays when this user should be forbidden access.
1.3.6.1.4.1.3052.18.2.12.21.11.1.16ColumnacuFriBeginread-writecurrentTime of day (HH:MM) on Fridays when this user should be granted access.
1.3.6.1.4.1.3052.18.2.12.21.11.1.17ColumnacuFriEndread-writecurrentTime of day (HH:MM) on Fridays when this user should be forbidden access.
1.3.6.1.4.1.3052.18.2.12.21.11.1.18ColumnacuSatBeginread-writecurrentTime of day (HH:MM) on Saturdays when this user should be granted access.
1.3.6.1.4.1.3052.18.2.12.21.11.1.19ColumnacuSatEndread-writecurrentTime of day (HH:MM) on Saturdays when this user should be forbidden access.
1.3.6.1.4.1.3052.18.2.14Nodeaction
1.3.6.1.4.1.3052.18.2.14.3NodeactionSched
1.3.6.1.4.1.3052.18.2.14.3.1ScalaractionSchedEnableread-writecurrentON/OFF enable action schedule
1.3.6.1.4.1.3052.18.2.14.3.2ScalaractionSchedBeginread-writecurrentaction schedule begin time (HH:MM)
1.3.6.1.4.1.3052.18.2.14.3.3ScalaractionSchedEndread-writecurrentaction schedule end time (HH:MM)
1.3.6.1.4.1.3052.18.2.14.3.4ScalaractionSchedWeekdaysOnlyread-writecurrentON/OFF whether the action schedule applies to weekdays only (ON) or all days (OFF)
1.3.6.1.4.1.3052.18.2.14.4NodeactionAsentria
1.3.6.1.4.1.3052.18.2.14.4.1ScalaractionAsentriaRequireAckread-writecurrentON/OFF Asentria action requires an ack from the receiver
1.3.6.1.4.1.3052.18.2.14.4.2ScalaractionAsentriaVersionread-writecurrentversion 1.0 or 1.1
1.3.6.1.4.1.3052.18.2.14.4.3ScalaractionAsentriaTCPPortread-writecurrentTCP port used for TCP-based Asentria alarms
1.3.6.1.4.1.3052.18.2.14.6TableactionHostTablenot-accessiblecurrentTable of network hosts to use for network-based actions
1.3.6.1.4.1.3052.18.2.14.6.1RowactionHostEntrynot-accessiblecurrentEntry for table of network hosts to use for network-based actions
1.3.6.1.4.1.3052.18.2.14.6.1.1ColumnactionHostIndexread-onlycurrentIndex for table of network hosts to use for network-based actions
1.3.6.1.4.1.3052.18.2.14.6.1.2ColumnactionHostread-writecurrentHostname/IP address used as destination for network-based action (e.g., trap)
1.3.6.1.4.1.3052.18.2.14.7TableactionEmailTablenot-accessiblecurrentTable of email addresses to use for email actions
1.3.6.1.4.1.3052.18.2.14.7.1RowactionEmailEntrynot-accessiblecurrentEntry for table of email addresses to use for email actions
1.3.6.1.4.1.3052.18.2.14.7.1.1ColumnactionEmailIndexread-onlycurrentIndex for table of email addresses to use for email actions
1.3.6.1.4.1.3052.18.2.14.7.1.2ColumnactionEmailread-writecurrentemail address
1.3.6.1.4.1.3052.18.2.14.8ScalaractionParseErrorread-onlycurrentWhen a user attempts to configure an invalid action setting/ object, this object says why it was invalid.
1.3.6.1.4.1.3052.18.2.16Nodesys
1.3.6.1.4.1.3052.18.2.16.1NodesysTime
1.3.6.1.4.1.3052.18.2.16.1.1ScalarsysTimeAutoDSTread-writecurrentON/OFF automatically adjust for Daylight Savings Time
1.3.6.1.4.1.3052.18.2.16.1.2ScalarsysTimeGMTOffsetread-writecurrentAbsolute value of offset (hours) from GMT of the timezone
1.3.6.1.4.1.3052.18.2.16.1.3ScalarsysTimeGMTDirectionread-writecurrentDirection (AHEAD/BEHIND) of timezone relative to GMT
1.3.6.1.4.1.3052.18.2.16.1.4NodesysTimeNet
1.3.6.1.4.1.3052.18.2.16.1.4.1ScalarsysTimeNetEnableread-writecurrentNetwork time mode
1.3.6.1.4.1.3052.18.2.16.1.4.2TablesysTimeNetHostTablenot-accessiblecurrentTable of hosts to use for network time services
1.3.6.1.4.1.3052.18.2.16.1.4.2.1RowsysTimeNetHostEntrynot-accessiblecurrentEntry for table of hosts to use for network time services
1.3.6.1.4.1.3052.18.2.16.1.4.2.1.1ColumnsysTimeNetHostIndexread-onlycurrentIndex for table of hosts to use for network time services
1.3.6.1.4.1.3052.18.2.16.1.4.2.1.2ColumnsysTimeNetHostread-writecurrenthost to use for network time services
1.3.6.1.4.1.3052.18.2.16.2NodesysPT
1.3.6.1.4.1.3052.18.2.16.2.1ScalarsysPTTimeoutread-writecurrentTimeout (minutes) of inactivity after which a pass-through session is terminated (0 means it never terminates)
1.3.6.1.4.1.3052.18.2.16.2.2ScalarsysPTEndPauseread-writecurrentnumber of 16ths of a second between escape characters received on pass-through origin IO handle that are reuired for the escape characters to register as pass-…
1.3.6.1.4.1.3052.18.2.16.2.3ScalarsysPTJoinableread-writecurrentEnable joinable pass-through sessions.
1.3.6.1.4.1.3052.18.2.16.3ScalarsysMTUread-writecurrentMaximum transfer unit for ethernet interfaces
1.3.6.1.4.1.3052.18.2.16.4ScalarsysAnswerStringread-writecurrentString displayed upon login
1.3.6.1.4.1.3052.18.2.16.6ScalarsysEventFileIDread-writecurrentID string for events file
1.3.6.1.4.1.3052.18.2.16.7ScalarsysEscapeCharacterread-writecurrentDecimal ASCII code of the system escape character
1.3.6.1.4.1.3052.18.2.16.8NodesysTimeStamp
1.3.6.1.4.1.3052.18.2.16.8.1ScalarsysTimeStampTimeFormatread-writecurrentFormat of time stamp: HH:MM,HH:MM:SS,BLANK
1.3.6.1.4.1.3052.18.2.16.8.2ScalarsysTimeStampDateFormatread-writecurrentFormat of date stamp: MM/DD,MM/DD/YY,MM/DD/YYYY,BLANK
1.3.6.1.4.1.3052.18.2.16.8.3ScalarsysTimeStampSpaceAfterread-writecurrentON/OFF Inlude a space after timestamp
1.3.6.1.4.1.3052.18.2.16.9NodesysLog
1.3.6.1.4.1.3052.18.2.16.9.1ScalarsysLogModeread-writecurrentSyslog mode: disabled, emit UDP (REMOTE), save in a rotating file set (FILE), or emit on a listening socket (SERVER)
1.3.6.1.4.1.3052.18.2.16.9.2ScalarsysLoghostread-writecurrentSyslog host: destination machine when syslog mode is REMOTE
1.3.6.1.4.1.3052.18.2.16.9.3ScalarsysLogFilterread-writecurrentString describing what functions place data in the syslog
1.3.6.1.4.1.3052.18.2.16.9.4ScalarsysLogFileSizeread-writecurrentSize (in KB) of syslog files (when syslog mode is SERVER or FILE)
1.3.6.1.4.1.3052.18.2.16.9.5ScalarsysLogFileCountread-writecurrentNumber of files in syslog file set (when syslog mode is SERVER or FILE)
1.3.6.1.4.1.3052.18.2.16.9.6ScalarsysLogListenPortread-writecurrentTCP port on which the unit listens for a connection on which syslog data is dumped (when syslog mode is SERVER)
1.3.6.1.4.1.3052.18.2.16.10NodesysCRDB
1.3.6.1.4.1.3052.18.2.16.10.1ScalarsysCRDBCapacityread-onlycurrentCapacity of Call Record Database (in KB)
1.3.6.1.4.1.3052.18.2.16.10.2ScalarsysCRDBPercentFullread-onlycurrentPercent of the CRDB used
1.3.6.1.4.1.3052.18.2.16.10.3TablesysCRDBFileIDTablenot-accessiblecurrentTable of CRDB file IDs
1.3.6.1.4.1.3052.18.2.16.10.3.1RowsysCRDBFileIDEntrynot-accessiblecurrentEntry for table of CRDB file IDs
1.3.6.1.4.1.3052.18.2.16.10.3.1.1ColumnsysCRDBFileIDIndexread-onlycurrentIndex for table of CRDB file IDs
1.3.6.1.4.1.3052.18.2.16.10.3.1.2ColumnsysCRDBFileIDread-writecurrentID of CRDB file for this port-associated file x
1.3.6.1.4.1.3052.18.2.16.10.4TablesysCRDBFileEnforceMinTablenot-accessiblecurrentTable of CRDB file minimum size enforcement settings
1.3.6.1.4.1.3052.18.2.16.10.4.1RowsysCRDBFileEnforceMinEntrynot-accessiblecurrentEntry for table of CRDB file minimum size enforcement settings
1.3.6.1.4.1.3052.18.2.16.10.4.1.1ColumnsysCRDBFileEnforceMinIndexread-onlycurrentIndex for table of CRDB file minimum size enforcement settings
1.3.6.1.4.1.3052.18.2.16.10.4.1.2ColumnsysCRDBFileEnforceMinread-writecurrentON/OFF: enforce minimum size for this CRDB file x
1.3.6.1.4.1.3052.18.2.16.11ScalarsysCharMaskread-writecurrentCharacter mask used for ignoring certain characters on serial ports when assembling data records (when port mode is ASCII)
1.3.6.1.4.1.3052.18.2.16.12ScalarsysPromptread-writecurrentPrompt to use in a commnand session
1.3.6.1.4.1.3052.18.2.16.13ScalarsysBootStatusread-onlycurrentString describing the boot status of the unit (Booted OK/ still booting
1.3.6.1.4.1.3052.18.2.16.14NodesysLoc
1.3.6.1.4.1.3052.18.2.16.14.1ScalarsysLocLatituderead-writecurrentLatitude portion of geographic coordinates as string
1.3.6.1.4.1.3052.18.2.16.14.2ScalarsysLocLongituderead-writecurrentLongitude portion of geographic coordinates as string
1.3.6.1.4.1.3052.18.2.16.14.3ScalarsysLocXOffsetread-writecurrentX-offset portion of geographic coordinates as string
1.3.6.1.4.1.3052.18.2.16.14.4ScalarsysLocYOffsetread-writecurrentY offset portion of geographic coordinates as string
1.3.6.1.4.1.3052.18.2.16.14.5ScalarsysLocAngleread-writecurrentAngle portion of geographic coordinates as string
1.3.6.1.4.1.3052.18.2.16.14.6ScalarsysLocAltituderead-writecurrentAltitude as string
1.3.6.1.4.1.3052.18.2.16.16NodesysSleep
1.3.6.1.4.1.3052.18.2.16.16.1ScalarsysSleepEnableread-writecurrentEnables/disables sleep mode. The unit will go into sleep mode only if this is set to ON.
1.3.6.1.4.1.3052.18.2.16.16.2NodesysSleepSleep
1.3.6.1.4.1.3052.18.2.16.16.2.1ScalarsysSleepForceSleepread-writecurrentWrite any value to this object to put the unit into sleep mode immediately (provided sleep mode is enabled)
1.3.6.1.4.1.3052.18.2.16.16.2.2ScalarsysSleepSleepTimerread-writecurrentHow long, in minutes, before the unit will go into sleep mode, measured from the time it is fully started up, or from the time generator/shore power is lost. A…
1.3.6.1.4.1.3052.18.2.16.16.3NodesysSleepWake
1.3.6.1.4.1.3052.18.2.16.16.3.1ScalarsysSleepWakeTimerNormalread-writecurrentHow long, in minutes, the unit will sleep once it goes into sleep mode, unless something else, such as generator/shore power restoration or movement, causes wa…
1.3.6.1.4.1.3052.18.2.16.16.3.2ScalarsysSleepWakeTimerMotionread-writecurrentHow long, in minutes, the unit will sleep once it goes into sleep mode, unless something else, such as generator/shore power restoration, causes wake-up. This …
1.3.6.1.4.1.3052.18.2.16.16.3.3ScalarsysSleepWakeMotionEnableread-writecurrentEnables/disables waking on detected motion.
1.3.6.1.4.1.3052.18.2.16.16.3.4ScalarsysSleepWakeScheduledEnableread-writecurrentEnabled/disables waking at a specified time of day.
1.3.6.1.4.1.3052.18.2.16.16.3.5ScalarsysSleepWakeScheduledTimeOfDayread-writecurrentSpecifies what time of day to wake up. Value is in HH:MM format.
1.3.6.1.4.1.3052.18.2.16.16.4NodesysSleepPowerDetectCC
1.3.6.1.4.1.3052.18.2.16.16.4.1ScalarsysSleepPowerDetectCCEnableread-writecurrentEnables/disables detection of generator/shore power via contact closure 1.
1.3.6.1.4.1.3052.18.2.16.16.4.2ScalarsysSleepPowerDetectCCPowerOnStateread-writecurrentSets the state (open or closed) that represents generator/shore power being present.
1.3.6.1.4.1.3052.18.2.16.16.4.3ScalarsysSleepPowerDetectCCThresholdread-writecurrentSets the time period, in seconds, for how long the CC must be in a given state for generator/shore power to be considered present or not.
1.3.6.1.4.1.3052.18.2.16.17NodesysFileTransfer
1.3.6.1.4.1.3052.18.2.16.17.1ScalarsysFileTransferStatusread-writecurrentStart/cancel file transfer, or check transfer status. To start, set this object to 'start'. To cancel, set this object to 'cancel'. To check status, get the ob…
1.3.6.1.4.1.3052.18.2.16.17.2ScalarsysFileTransferURLread-writecurrentURL (describing protocol, host, directory, and file) on which file transfer function operates.
1.3.6.1.4.1.3052.18.2.16.17.3ScalarsysFileTransferUsernameread-writecurrentUsername for user account at the resource specified by sysFileTransferURL.
1.3.6.1.4.1.3052.18.2.16.17.4ScalarsysFileTransferPasswordread-writecurrentPassword for user account at the resource specified by sysFileTransferURL.
1.3.6.1.4.1.3052.18.2.16.18NodesysUpdate
1.3.6.1.4.1.3052.18.2.16.18.1ScalarsysUpdateStatusread-onlycurrentCheck time/result of last update attempt.
1.3.6.1.4.1.3052.18.2.17NodeauditLog
1.3.6.1.4.1.3052.18.2.17.1ScalarauditLogEnableread-writecurrentON/OFF enable audit log
1.3.6.1.4.1.3052.18.2.17.2ScalarauditLogStoreResetsread-writecurrentON/OFF audit log stores when the unit resets
1.3.6.1.4.1.3052.18.2.17.3ScalarauditLogStoreCommandsread-writecurrentON/OFF audit log stores commands entered in a command session
1.3.6.1.4.1.3052.18.2.17.4ScalarauditLogStoreOutputsread-writecurrentON/OFF audit log stores output (relay output and power output) activity
1.3.6.1.4.1.3052.18.2.17.5ScalarauditLogStoreAlarmActionsread-writecurrentON/OFF audit log stores action delivery activity
1.3.6.1.4.1.3052.18.2.17.6ScalarauditLogStorePwdFailuresread-writecurrentON/OFF audit log stores when user was denied login
1.3.6.1.4.1.3052.18.2.17.7ScalarauditLogStoreLoginsread-writecurrentON/OFF audit log stores when a user was allowed login
1.3.6.1.4.1.3052.18.2.17.8ScalarauditLogStoreSHSKread-writecurrentON/OFF audit log stores serial handshaking status (regardless of serial handshaking event)
1.3.6.1.4.1.3052.18.2.17.9ScalarauditLogStorePassthroughread-writecurrentON/OFF audit log stores pass-through activity
1.3.6.1.4.1.3052.18.2.17.10ScalarauditLogStoreInactivityread-writecurrentON/OFF audit log stores when sessions expire due to inactivity
1.3.6.1.4.1.3052.18.2.17.11ScalarauditLogStorePollingread-writecurrentON/OFF audit log stores CRDB polling activity
1.3.6.1.4.1.3052.18.2.17.12ScalarauditLogMaxSizeread-writecurrentMaximum size (in KB) of audit log
1.3.6.1.4.1.3052.18.2.17.13ScalarauditLogSoreSleepActivityread-writecurrentON/OFF audit log stores sleep activity
1.3.6.1.4.1.3052.18.2.18Nodescripting
1.3.6.1.4.1.3052.18.2.18.1ScalarscrGlobalEnableread-writecurrentON/OFF enable scripting
1.3.6.1.4.1.3052.18.2.18.2TablescrDTRCtrlPortEnableTablenot-accessiblecurrentTable of DTR control port enables
1.3.6.1.4.1.3052.18.2.18.2.1RowscrDTRCtrlPortEnableEntrynot-accessiblecurrentEntry for table of DTR control port enables
1.3.6.1.4.1.3052.18.2.18.2.1.1ColumnscrDTRCtrlPortEnableIndexread-onlycurrentIndex for table of DTR control port enables
1.3.6.1.4.1.3052.18.2.18.2.1.2ColumnscrDTRCtrlPortEnableread-writecurrentON/OFF enable DTR control of scripting for this port
1.3.6.1.4.1.3052.18.2.18.3TablescrTablenot-accessiblecurrentTable of scripts
1.3.6.1.4.1.3052.18.2.18.3.1RowscrEntrynot-accessiblecurrentEntry for table of scripts
1.3.6.1.4.1.3052.18.2.18.3.1.1ColumnscrIndexread-onlycurrentIndex for table of scripts
1.3.6.1.4.1.3052.18.2.18.3.1.2ColumnscrEnableread-writecurrentON/OFF enable this script
1.3.6.1.4.1.3052.18.2.18.3.1.3ColumnscrNameread-writecurrentName of this script
1.3.6.1.4.1.3052.18.2.18.3.1.4ColumnscrFilenameread-writecurrentFilename for this script
1.3.6.1.4.1.3052.18.2.18.3.1.5ColumnscrRunAlwaysread-writecurrentON/OFF: this script always runs
1.3.6.1.4.1.3052.18.2.18.3.1.6ColumnscrRunAtStartupread-writecurrentON/OFF: this script runs at startup
1.3.6.1.4.1.3052.18.2.18.3.1.7ColumnscrRunScheduledread-writecurrentON/OFF: this script runs at a certain time of day
1.3.6.1.4.1.3052.18.2.18.3.1.8ColumnscrScheduleTimeread-writecurrentTime of day (HH:MM) this script is scheduled to run
1.3.6.1.4.1.3052.18.2.18.3.1.9ColumnscrArgumentsread-writecurrentArguments for this script
1.3.6.1.4.1.3052.18.2.18.3.1.10ColumnscrRepeatIntervalread-writecurrentHow often this script runs (minutes)
1.3.6.1.4.1.3052.18.2.18.4TablescrVolatileStringTablenot-accessiblecurrentTable of volatile string settings for use in scripts.
1.3.6.1.4.1.3052.18.2.18.4.1RowscrVolatileStringEntrynot-accessiblecurrentEntry for table of volatile script string settings
1.3.6.1.4.1.3052.18.2.18.4.1.1ColumnscrVolatileStringIndexread-onlycurrentIndex for table of volatile script string settings
1.3.6.1.4.1.3052.18.2.18.4.1.2ColumnscrVolatileStringread-writecurrentVolatile string for use in scripts. Use this object to cache frequently-changing string values or string values that do not need to persist through reset. This…
1.3.6.1.4.1.3052.18.2.18.5TablescrVolatileIntTablenot-accessiblecurrentTable of volatile integer settings for use in scripts.
1.3.6.1.4.1.3052.18.2.18.5.1RowscrVolatileIntEntrynot-accessiblecurrentEntry for table of volatile script integer settings
1.3.6.1.4.1.3052.18.2.18.5.1.1ColumnscrVolatileIntIndexread-onlycurrentIndex for table of volatile script integer settings
1.3.6.1.4.1.3052.18.2.18.5.1.2ColumnscrVolatileIntread-writecurrentVolatile integer for use in scripts. Use this object to cache frequently-changing integer values or integer values that do not need to persist through reset. T…
1.3.6.1.4.1.3052.18.2.18.6TablescrNonVolatileStringTablenot-accessiblecurrentTable of non-volatile string settings for use in scripts.
1.3.6.1.4.1.3052.18.2.18.6.1RowscrNonVolatileStringEntrynot-accessiblecurrentEntry for table of non-volatile script string settings
1.3.6.1.4.1.3052.18.2.18.6.1.1ColumnscrNonVolatileStringIndexread-onlycurrentIndex for table of non-volatile script string settings
1.3.6.1.4.1.3052.18.2.18.6.1.2ColumnscrNonVolatileStringread-writecurrentNon-volatile string for use in scripts. Use this object to store values that need to persist through reset. This object corresponds to the scripting.nvstring[]…
1.3.6.1.4.1.3052.18.2.18.7TablescrNonVolatileIntTablenot-accessiblecurrentTable of non-volatile integer settings for use in scripts.
1.3.6.1.4.1.3052.18.2.18.7.1RowscrNonVolatileIntEntrynot-accessiblecurrentEntry for table of non-volatile script integer settings
1.3.6.1.4.1.3052.18.2.18.7.1.1ColumnscrNonVolatileIntIndexread-onlycurrentIndex for table of non-volatile script integer settings
1.3.6.1.4.1.3052.18.2.18.7.1.2ColumnscrNonVolatileIntread-writecurrentNon-volatile integer for use in scripts. Use this object to store integer values that need to persist through reset. This object corresponds to the scripting.n…
1.3.6.1.4.1.3052.18.2.19Nodegenerator
1.3.6.1.4.1.3052.18.2.19.1NodegenSet
1.3.6.1.4.1.3052.18.2.19.1.1ScalargenSetEnableread-writecurrentEnable genset functionality; that is, a generator is in use.
1.3.6.1.4.1.3052.18.2.19.1.2NodegenSetRelay
1.3.6.1.4.1.3052.18.2.19.1.2.1ScalargenSetRelayEsread-writecurrentWhich EventSensor has the relay which starts the generator, for genset relay configuration 1 only. This object maps to the same setting as genSetRelayTableEs.1.
1.3.6.1.4.1.3052.18.2.19.1.2.2ScalargenSetRelayPointread-writecurrentWhich relay starts the generator, for genset relay configuration 1 only. This object maps to the same setting as genSetRelayTablePoint.1.
1.3.6.1.4.1.3052.18.2.19.1.2.3ScalargenSetRelayRunningstateread-writecurrentWhich relay state corresponds with the generator starting/running. This object maps to the same setting as genSetRelayTableRunningstate.1.
1.3.6.1.4.1.3052.18.2.19.1.2.5TablegenSetRelayTablenot-accessiblecurrentTable of relays for genset ignition.
1.3.6.1.4.1.3052.18.2.19.1.2.5.1RowgenSetRelayTableEntrynot-accessiblecurrentEntry for table of relays for genset ignition.
1.3.6.1.4.1.3052.18.2.19.1.2.5.1.1ColumngenSetRelayTableIndexread-onlycurrentIndex for table of relays for genset ignition.
1.3.6.1.4.1.3052.18.2.19.1.2.5.1.2ColumngenSetRelayTableEnableread-writecurrentEnable this relay for starting the generator.
1.3.6.1.4.1.3052.18.2.19.1.2.5.1.3ColumngenSetRelayTableEsread-writecurrentWhich EventSensor has the relay which starts the generator, for this genset relay configuration specified by the table index.
1.3.6.1.4.1.3052.18.2.19.1.2.5.1.4ColumngenSetRelayTablePointread-writecurrentWhich relay point on the EventSensor used for starting the generator, for this genset relay configuration specified by the table index.
1.3.6.1.4.1.3052.18.2.19.1.2.5.1.5ColumngenSetRelayTableRunningstateread-writecurrentWhich relay state corresponds with the generator starting/running, for this genset relay configuration specified by the table index.
1.3.6.1.4.1.3052.18.2.19.1.3NodegenSetCC
1.3.6.1.4.1.3052.18.2.19.1.3.1ScalargenSetCCEnableread-writecurrentEnable generator running detection functionality; that is, the associated CC is valid for determining if generator is running.
1.3.6.1.4.1.3052.18.2.19.1.3.2ScalargenSetCCEsread-writecurrentWhich CC EventSensor has the CC which is connected to the genertor running detection monitor.
1.3.6.1.4.1.3052.18.2.19.1.3.3ScalargenSetCCPointread-writecurrentWhich CC is connected to the genertor running detection monitor.
1.3.6.1.4.1.3052.18.2.19.1.3.4ScalargenSetCCRunningStateread-writecurrentWhich CC physical state corresponds with the generator running.
1.3.6.1.4.1.3052.18.2.19.1.3.5ScalargenSetCCDelayread-writecurrentHow long (in seconds) to wait for the generator to indicate itself as running after engaging the generator-starting mechanism.
1.3.6.1.4.1.3052.18.2.19.2NodegenRun
1.3.6.1.4.1.3052.18.2.19.2.1ScalargenRunModeread-writecurrentGenerator Exercising function main operating mode; set to INHIBIT to inhibit exercising the generator.
1.3.6.1.4.1.3052.18.2.19.2.2ScalargenRunSchedread-writecurrentSchedule number(s) which govern(s) when Generator Exercising function runs.
1.3.6.1.4.1.3052.18.2.19.2.3ScalargenRunDurationread-writecurrentNumber of seconds that generator should run, started when the generator needs to start by SCHEDULE or by being forced to start.
1.3.6.1.4.1.3052.18.2.19.2.4ScalargenRunForceread-writecurrentWrite 1 to this to force the generator exercising to start. Always reads as 0.
1.3.6.1.4.1.3052.18.2.19.2.5ScalargenRunReqasmread-writecurrentRequire ASM connectivity before starting the generator from a schedule.
1.3.6.1.4.1.3052.18.2.19.2.6ScalargenRunStatusread-onlycurrentStatus of Generator Exercising function.
1.3.6.1.4.1.3052.18.2.19.2.7NodegenRunNonstartEvent
1.3.6.1.4.1.3052.18.2.19.2.7.1ScalargenRunNonstartEventEnableread-writecurrentEnable generator non-start event.
1.3.6.1.4.1.3052.18.2.19.2.7.2ScalargenRunNonstartEventActionsread-writecurrentActions for generator non-start event.
1.3.6.1.4.1.3052.18.2.19.2.7.3ScalargenRunNonstartEventTrapread-writecurrentTrap number for generator non-start event.
1.3.6.1.4.1.3052.18.2.19.2.7.4ScalargenRunNonstartEventClassread-writecurrentClass (severity) for generator non-start event.
1.3.6.1.4.1.3052.18.2.20Nodecalendar
1.3.6.1.4.1.3052.18.2.20.1TableschedTablenot-accessiblecurrentTable of schedules
1.3.6.1.4.1.3052.18.2.20.1.1RowschedEntrynot-accessiblecurrentEntry for table of schedules.
1.3.6.1.4.1.3052.18.2.20.1.1.1ColumnschedIndexread-onlycurrentIndex for table of schedules.
1.3.6.1.4.1.3052.18.2.20.1.1.2ColumnschedEnableread-writecurrentEnable this schedule.
1.3.6.1.4.1.3052.18.2.20.1.1.3ColumnschedStartread-writecurrentThis is of the form 'mm/dd/yy hh:mm:ss'. This controls on which date/time the schedule starts.
1.3.6.1.4.1.3052.18.2.20.1.1.4ColumnschedRepeatModeread-writecurrentControls in which way the schedule should repeat.
1.3.6.1.4.1.3052.18.2.20.1.1.5ColumnschedRepeatFreqread-writecurrentControls how often the schedule should repeat: every nth day, week, month, or year.
1.3.6.1.4.1.3052.18.2.20.1.1.6ColumnschedRepeatEndModeread-writecurrentControls how the repeating schedule should end.
1.3.6.1.4.1.3052.18.2.20.1.1.7ColumnschedRepeatEndAfterread-writecurrentNumber of times this schedule should be repeated; relevant when the repeat end mode is AFTER.
1.3.6.1.4.1.3052.18.2.20.1.1.8ColumnschedRepeatEndOnread-writecurrentDate/time (in the form 'mm/yy/dd hh:mm:ss' or blank string) after which repeating should end, relevant when repeat end mode is ON DATE.
1.3.6.1.4.1.3052.18.2.20.1.1.9ColumnschedRepeatWeeklySunread-writecurrentRun this schedule on Sunday(s); relevant when repeat mode is weekly.
1.3.6.1.4.1.3052.18.2.20.1.1.10ColumnschedRepeatWeeklyMonread-writecurrentRun this schedule on Monday(s); relevant when repeat mode is weekly.
1.3.6.1.4.1.3052.18.2.20.1.1.11ColumnschedRepeatWeeklyTueread-writecurrentRun this schedule on Tuesday(s); relevant when repeat mode is weekly.
1.3.6.1.4.1.3052.18.2.20.1.1.12ColumnschedRepeatWeeklyWedread-writecurrentRun this schedule on Wednesday(s); relevant when repeat mode is weekly.
1.3.6.1.4.1.3052.18.2.20.1.1.13ColumnschedRepeatWeeklyThuread-writecurrentRun this schedule on Thursday(s); relevant when repeat mode is weekly.
1.3.6.1.4.1.3052.18.2.20.1.1.14ColumnschedRepeatWeeklyFriread-writecurrentRun this schedule on Friday(s); relevant when repeat mode is weekly.
1.3.6.1.4.1.3052.18.2.20.1.1.15ColumnschedRepeatWeeklySatread-writecurrentRun this schedule on Saturday(s); relevant when repeat mode is weekly.
1.3.6.1.4.1.3052.18.2.20.1.1.16ColumnschedRepeatMonthlyModeread-writecurrentEACH means the schedule runs on specific dates of the month. ON THE means the schedule runs on calculated dates of the month according to which day that month …
1.3.6.1.4.1.3052.18.2.20.1.1.17ColumnschedRepeatMonthlyDatesread-writecurrentComma-separated list of dates of a month on which this schedule should run, relevant when repeat monthly mode is EACH.
1.3.6.1.4.1.3052.18.2.20.1.1.18ColumnschedRepeatMonthlyOnTheread-writecurrentControls on which day of the month this schedule should run, relevant when repeat monthly mode is ON THE.
1.3.6.1.4.1.3052.18.2.20.1.1.19ColumnschedRepeatMonthlyOnDayread-writecurrentControls the day of week on which this schedule is run, relevant when repeat monthly mode is ON THE
1.3.6.1.4.1.3052.18.2.20.1.1.20ColumnschedRepeatYearlyJanread-writecurrentRun this schedule in January, relevant when repeat mode is YEARLY.
1.3.6.1.4.1.3052.18.2.20.1.1.21ColumnschedRepeatYearlyFebread-writecurrentRun this schedule in February, relevant when repeat mode is YEARLY.
1.3.6.1.4.1.3052.18.2.20.1.1.22ColumnschedRepeatYearlyMarread-writecurrentRun this schedule in March, relevant when repeat mode is YEARLY.
1.3.6.1.4.1.3052.18.2.20.1.1.23ColumnschedRepeatYearlyAprread-writecurrentRun this schedule in April, relevant when repeat mode is YEARLY.
1.3.6.1.4.1.3052.18.2.20.1.1.24ColumnschedRepeatYearlyMayread-writecurrentRun this schedule in May, relevant when repeat mode is YEARLY.
1.3.6.1.4.1.3052.18.2.20.1.1.25ColumnschedRepeatYearlyJunread-writecurrentRun this schedule in June, relevant when repeat mode is YEARLY.
1.3.6.1.4.1.3052.18.2.20.1.1.26ColumnschedRepeatYearlyJulread-writecurrentRun this schedule in July, relevant when repeat mode is YEARLY.
1.3.6.1.4.1.3052.18.2.20.1.1.27ColumnschedRepeatYearlyAugread-writecurrentRun this schedule in August, relevant when repeat mode is YEARLY.
1.3.6.1.4.1.3052.18.2.20.1.1.28ColumnschedRepeatYearlySepread-writecurrentRun this schedule in September, relevant when repeat mode is YEARLY.
1.3.6.1.4.1.3052.18.2.20.1.1.29ColumnschedRepeatYearlyOctread-writecurrentRun this schedule in October, relevant when repeat mode is YEARLY.
1.3.6.1.4.1.3052.18.2.20.1.1.30ColumnschedRepeatYearlyNovread-writecurrentRun this schedule in November, relevant when repeat mode is YEARLY.
1.3.6.1.4.1.3052.18.2.20.1.1.31ColumnschedRepeatYearlyDecread-writecurrentRun this schedule in December, relevant when repeat mode is YEARLY.
1.3.6.1.4.1.3052.18.2.20.1.1.32ColumnschedRepeatYearlyOnTheread-writecurrentControls on which day of the month this schedule should run, relevant when repeat mode is YEARLY.
1.3.6.1.4.1.3052.18.2.20.1.1.33ColumnschedRepeatYearlyOnDayread-writecurrentControls the day of week on which this schedule is run, relevant when repeat mode is YEARLY.
1.3.6.1.4.1.3052.18.2.20.1.1.34ColumnschedNextTriggerread-onlycurrentWhen this schedule will next trigger.
1.3.6.1.4.1.3052.18.3NodeproductIds
1.3.6.1.4.1.3052.18.3.1ScalarsiteNameread-onlycurrentSite Name string; Max 40 characters.
1.3.6.1.4.1.3052.18.3.2ScalarthisProductread-onlycurrentThis is a factory configured string for the product name.
1.3.6.1.4.1.3052.18.3.3ScalarstockTrapStringread-onlycurrentThe message defined for the event that triggers a trap.
1.3.6.1.4.1.3052.18.3.4ScalartrapEventTypeNumberread-onlycurrentThe user-defined trap variable for the type of event that happened. Definitions: 4 Scheduled 7 Serial Handshaking Low 8 Serial Handshaking High 10 Contact Clos…
1.3.6.1.4.1.3052.18.3.5ScalartrapEventTypeNameread-onlycurrentThe user-defined trap variable for the string corresponding to the event type.
1.3.6.1.4.1.3052.18.3.6ScalartrapIncludedValueread-onlycurrentThe user-defined trap variable for the generic included value.
1.3.6.1.4.1.3052.18.3.7ScalartrapIncludedStringread-onlycurrentThe user-defined trap variable for the generic included string.
1.3.6.1.4.1.3052.18.3.8ScalartrapTypeStringread-onlycurrentThe cause of the trap, added for DL880 compatibility.
1.3.6.1.4.1.3052.18.3.9ScalartrapEventClassNumberread-onlycurrentThe user-defined trap variable for the configurable class number associated with the triggering event.
1.3.6.1.4.1.3052.18.3.10ScalartrapEventClassNameread-onlycurrentThe user-defined trap variable for the configurable class name associated with the class number.
1.3.6.1.4.1.3052.18.4ScalarkeyInterfaceread-writecurrentThis object represents a setting key interface. When setting this object, the value to set is the 'sk' command you would enter on the command line (without the…