This MIB module describes the SiteLight ALS feature.
OIDNameAccessStatusDescription
1.3.6.1.4.1.4515.1.12IdentityslAlsMibThis MIB module describes the SiteLight ALS feature.
1.3.6.1.4.1.4515.1.12.1NodeslAlsConfig
1.3.6.1.4.1.4515.1.12.1.1TableslAlsConfigTablenot-accessiblecurrentThe ALS configuration Table.
1.3.6.1.4.1.4515.1.12.1.1.1RowslAlsConfigEntrynot-accessiblecurrentThe entries exist for active optical inetfaces ifType = 196. The objects in this table are used to configure the ALS algorithm.
1.3.6.1.4.1.4515.1.12.1.1.1.1ColumnslAlsModeread-writecurrentEnable/Disable the ALS algorithm. When the Laser Admin Status is 'down' the ALS not operational.
1.3.6.1.4.1.4515.1.12.1.1.1.2ColumnslAlsLosDeclareTimeread-writecurrentTime to declare optical LOS present or clear
1.3.6.1.4.1.4515.1.12.1.1.1.3ColumnslAlsTestPulseTimeread-writecurrentManual restart for test Pulse time (in manual restart) - 90+-10 sec.
1.3.6.1.4.1.4515.1.12.1.1.1.4ColumnslAlsManualPulseTimeread-writecurrent
1.3.6.1.4.1.4515.1.12.1.1.1.5ColumnslAlsAutomaticPulseTimeread-writecurrent
1.3.6.1.4.1.4515.1.12.1.1.1.6ColumnslAlsAutomaticDelayTimeread-writecurrentIn Automatic mode. The delay between two laser re-activations.
1.3.6.1.4.1.4515.1.12.1.1.1.7ColumnslAlsLaserTestActivateread-writecurrentActivate the laser for test operation.
1.3.6.1.4.1.4515.1.12.1.1.1.8ColumnslAlsLaserManualActivateread-writecurrentActivate the laser manual operation.
1.3.6.1.4.1.4515.1.12.1.1.1.9ColumnslAlsOperStatusread-onlycurrentThe operational status of the ALS algorithm. When the Laser Admin Status is 'down' the ALS not operational.
1.3.6.1.4.1.4515.1.12.1.1.1.10ColumnslAlsResetParamsread-writecurrentSetting this variable to 1 will reset the ALS parameters to the factory defaults.
1.3.6.1.4.1.4515.1.12.2NodeslAlsTraps
1.3.6.1.4.1.4515.1.12.2.1NotificationslAlsStatusChangeTrapcurrentA slAlsStatusChangeTrap is sent when the TX laser status is changed.
Type Definitions
NameSyntaxStatusDescription
AlsAutomaticPulseTimeTypeINTEGER { ms1750(1), ms2000(2), ms2250(3) }currentAutomatic restart Pulse time (in automatic mode) - 2+-0.25 sec.
AlsManualPulseTimeTypeINTEGER { ms1750(1), ms2000(2), ms2250(3) }currentManual restart Pulse time (in manual mode) - 2+-0.25 sec.