SL-EDFA-MIB
48 objects
This MIB module describes the EDFA Cards
Imported Objects
| IF-MIB | InterfaceIndex |
| PerfHist-TC-MIB | PerfCurrentCount PerfIntervalCount PerfTotalCount |
| SL-NE-MIB | sitelight |
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE TimeTicks |
| SNMPv2-TC | DisplayString TimeStamp TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4515.1.9 | IdentityslEdfa | This MIB module describes the EDFA Cards | ||
| 1.3.6.1.4.1.4515.1.9.1 | NodeedfaConfig | |||
| 1.3.6.1.4.1.4515.1.9.1.1 | TableedfaConfigTable | not-accessible | current | The EDFA configuration table. |
| 1.3.6.1.4.1.4515.1.9.1.1.1 | RowedfaConfigEntry | not-accessible | current | An entry in the EDFA interface configuration table. The index to this table is the same as the an ifIndex. |
| 1.3.6.1.4.1.4515.1.9.1.1.1.1 | ColumnedfaIfIndex | read-only | current | The amplifier interface index. |
| 1.3.6.1.4.1.4515.1.9.1.1.1.2 | ColumnedfaPumpTemp | read-only | current | The pump temperture (in Kelvin). |
| 1.3.6.1.4.1.4515.1.9.1.1.1.3 | ColumnedfaRxPower | read-only | current | The measured Rx Power. The value is specified in ten'th of Dbm units increments, starting from -30.0 dbm (e.g. value 0 means -30.0 dbm). |
| 1.3.6.1.4.1.4515.1.9.1.1.1.4 | ColumnedfaPumpAdminStatus | read-write | current | The desired state of the laser. The restart(3) state indicates that the edfa pump should be restarted. The restart(3) is not a state, thus it is not kept in th… |
| 1.3.6.1.4.1.4515.1.9.1.1.1.5 | ColumnedfaPumpOperStatus | read-only | current | The current operational state of the laser. If edfaPumpAdminStatus is down(2) then edfaPumpOperStatus should be down(2). If edfaPumpAdminStatus is changed to u… |
| 1.3.6.1.4.1.4515.1.9.1.1.1.6 | ColumnedfaStatus | read-only | current | This variable indicates the Line Status of the Edfa module. The edfaStatus is a bit map represented as a sum, therefore, it can represent multiple failures (al… |
| 1.3.6.1.4.1.4515.1.9.1.1.1.7 | ColumnedfaVoa | read-only | current | The computed VOA output attenuation specified in 0.1 dB units. From 0.0 to +15.0 dB. |
| 1.3.6.1.4.1.4515.1.9.1.1.1.8 | ColumnedfaAutomaticMode | read-write | current | Defines the Edfa automatic mode. If equals TRUE, the Edfa control mode should selected automaticaly. Otherwise it should be selected manualy. |
| 1.3.6.1.4.1.4515.1.9.1.1.1.9 | ColumnedfaAdminControlMode | read-write | current | Configure the Edfa control mode. This object may be set only when edfaAtomaticMode is FALSE. |
| 1.3.6.1.4.1.4515.1.9.1.1.1.10 | ColumnedfaOperControlMode | read-only | current | The current Edfa control mode. Initialy the Edfa starts in APC mode. The AGC mode is used only when selected manualy or after transient input power change. |
| 1.3.6.1.4.1.4515.1.9.1.1.1.11 | ColumnedfaAdminGain | read-write | current | The required Edfa Gain value given in 0.1 dB units. This value may be configured only when the edfa automatic mode is FALSE and the edfa control mode is Agc. |
| 1.3.6.1.4.1.4515.1.9.1.1.1.12 | ColumnedfaOperGain | read-only | current | The actual Edfa Gain value given in 0.1 dB units. Value range starts with 0.0 dbm |
| 1.3.6.1.4.1.4515.1.9.1.1.1.13 | ColumnedfaAdminOutputPower | read-write | current | The required Edfa output power value given in 0.1 dBm units. The range starts with -30.0 dBm. This value may be configured only when the edfa control mode is A… |
| 1.3.6.1.4.1.4515.1.9.1.1.1.14 | ColumnedfaOperOutputPower | read-only | current | The actual Edfa total output power value specified in 0.1 dBm units. Valid valuse are in the range of 0.0 dBm upto +15.0 dBm. The units in the case of RAMAN AM… |
| 1.3.6.1.4.1.4515.1.9.1.1.1.15 | ColumnedfaChannelsNumber | read-only | current | The number of optical channels on this signal. |
| 1.3.6.1.4.1.4515.1.9.1.1.1.16 | ColumnedfaTotalChannelsNumber | read-only | current | The total number of optical channels on this fiber. |
| 1.3.6.1.4.1.4515.1.9.1.1.1.17 | ColumnedfaEyeSafetyMode | read-write | current | When in Eye-Safety mode the edfa reduces the laser power budget down to safe level upon detection of an output fiber cut. |
| 1.3.6.1.4.1.4515.1.9.1.1.1.18 | ColumnedfaShutDownLipEnable | read-write | current | EDFA shout-down on LIP (Loss of signal) - enable/disable. |
| 1.3.6.1.4.1.4515.1.9.1.1.1.19 | ColumnedfaAutoPowerUpLipEnable | read-write | current | EDFA automatic power up (after signal returns) - enable/disable. |
| 1.3.6.1.4.1.4515.1.9.1.1.1.20 | ColumnedfaMaxGain | read-only | current | The EDFA max gain is determined by the result of the VER command. Legal values: gainUnknown(1) gain14dbm(2) - Booster/Inline, (-2)-14dBm output power, gain (-5… |
| 1.3.6.1.4.1.4515.1.9.1.1.1.21 | ColumnedfaGainInFrom | read-only | current | Lower input gain range of the edfa in units of 0.1 db. |
| 1.3.6.1.4.1.4515.1.9.1.1.1.22 | ColumnedfaGainInTo | read-only | current | Upper input gain range of the edfa in units of 0.1 db. |
| 1.3.6.1.4.1.4515.1.9.1.1.1.23 | ColumnedfaGainOutFrom | read-only | current | Lower output gain range of the edfa in units of 0.1 db. |
| 1.3.6.1.4.1.4515.1.9.1.1.1.24 | ColumnedfaGainOutTo | read-only | current | Upper output gain range of the edfa in units of 0.1 db. |
| 1.3.6.1.4.1.4515.1.9.1.1.1.25 | ColumnedfaPowerInFrom | read-only | current | Lower input power range of the edfa in units of 0.1 dbm. |
| 1.3.6.1.4.1.4515.1.9.1.1.1.26 | ColumnedfaPowerInTo | read-only | current | Upper input power range of the edfa in units of 0.1 dbm. |
| 1.3.6.1.4.1.4515.1.9.1.1.1.27 | ColumnedfaPowerOutFrom | read-only | current | Lower output power range of the edfa in units of 0.1 dbm. In the case of RAMAN AMP the units are mW. |
| 1.3.6.1.4.1.4515.1.9.1.1.1.28 | ColumnedfaPowerOutTo | read-only | current | Upper output power range of the edfa in units of 0.1 dbm. In the case of RAMAN AMP the units are mW. |
| 1.3.6.1.4.1.4515.1.9.1.1.1.29 | ColumnedfaFromChannel | read-only | current | The first channel number supported by the edfa; 0 to ignore. |
| 1.3.6.1.4.1.4515.1.9.1.1.1.30 | ColumnedfaToChannel | read-only | current | The last channel number supported by the edfa; 0 to ignore. |
| 1.3.6.1.4.1.4515.1.9.1.1.1.31 | ColumnedfaOscChannel | read-only | current | The wavelenght of the optical supervisory channel e.g. 1510, 1490. |
| 1.3.6.1.4.1.4515.1.9.1.1.1.32 | ColumnedfaRedBlueType | read-only | current | The type of the edaf. |
| 1.3.6.1.4.1.4515.1.9.1.1.1.33 | ColumnedfaRole | read-only | current | The role of the edaf. |
| 1.3.6.1.4.1.4515.1.9.1.1.1.34 | ColumnedfaFreeDescription | read-only | current | A free text with additional edfa information. |
| 1.3.6.1.4.1.4515.1.9.1.1.1.35 | ColumnedfaConfigSafetyThreshold | read-write | current | The Eye Safety threshold level specified in dBm units. The value given in 0.1 dBm units. The range starts with -50.0 dBm. |
| 1.3.6.1.4.1.4515.1.9.1.1.1.36 | ColumnedfaSigOutputPower | read-only | current | The measured Signal output Power. The value is specified in ten'th of Dbm units increments, starting from -30.0 dbm (e.g. value 0 means -30.0 dbm). |
| 1.3.6.1.4.1.4515.1.9.1.1.1.37 | ColumnedfaLossPropagation | read-write | current | Applicable for pre-amp. Controls the pump behaviour in case of a LOS. disabled - the pump is not shut-down to fasten the return-from-loss time. enabled - the p… |
| 1.3.6.1.4.1.4515.1.9.1.2 | ScalaredfaConfigAmpMngPort | read-write | current | The management port connected to the amplifier. May be used for RAMAN amplifier for enehanced eye-safety mechanism. If enabled, it is used to shut-down the AMP… |
| 1.3.6.1.4.1.4515.1.9.2 | NodeedfaTraps | |||
| 1.3.6.1.4.1.4515.1.9.2.0 | NodeedfaTraps0 | |||
| 1.3.6.1.4.1.4515.1.9.2.0.1 | NotificationedfaStatusChange0 | current | A edfaStatusChange trap is sent when the value of an instance edfaStatus changes. It can be utilized by an NMS to trigger polls. It is defined to support brows… | |
| 1.3.6.1.4.1.4515.1.9.2.0.2 | NotificationedfaControlModeChange0 | current | A edfaControlModeChange trap is sent when the value of an instance edfaOperControlMode when going from APC to AGC (both directions) in automatic mode. It is de… | |
| 1.3.6.1.4.1.4515.1.9.2.1 | NotificationedfaStatusChange | current | A edfaStatusChange trap is sent when the value of an instance edfaStatus changes. It can be utilized by an NMS to trigger polls. | |
| 1.3.6.1.4.1.4515.1.9.2.2 | NotificationedfaControlModeChange | current | A edfaControlModeChange trap is sent when the value of an instance edfaOperControlMode when going from APC to AGC (both directions) in automatic mode. |