SL-XPDR-MIB

31 objects
This MIB module describes the optical connections.
OIDNameAccessStatusDescription
1.3.6.1.4.1.4515.1.8IdentityslXpdrThis MIB module describes the optical connections.
1.3.6.1.4.1.4515.1.8.1NodeslXpdrConn
1.3.6.1.4.1.4515.1.8.1.1TablexpdrConnConfigTablenot-accessiblecurrentThe connection table contains for each transponding connection a single bi-directional entry. The index to the table is the ifIndex of both XPDR interfaces. Th…
1.3.6.1.4.1.4515.1.8.1.1.1RowxpdrConnConfigEntrynot-accessiblecurrentAn entry in the transponding connection table.
1.3.6.1.4.1.4515.1.8.1.1.1.1ColumnxpdrConnConfigIf1read-onlycurrentThe first XPDR interface.
1.3.6.1.4.1.4515.1.8.1.1.1.2ColumnxpdrConnConfigIf2read-onlycurrentThe second XPDR interface.
1.3.6.1.4.1.4515.1.8.1.1.1.3ColumnxpdrConnConfigRateControlAdminread-writecurrentThis variable ask the rate of the traffic used by this interface. Frequency is in Kbp/s. The value 0-30 is used for rate control Bypass.
1.3.6.1.4.1.4515.1.8.1.1.1.4ColumnxpdrConnConfigRateControlOperread-onlycurrentThis variable tells the rate of the traffic used by this interface. Frequency is in Kbp/s. The value 0 returned for rate control Bypass.
1.3.6.1.4.1.4515.1.8.1.1.1.5ColumnxpdrConnConfigLosPropagationread-writecurrentThis object is used to detrmine if the LOS propagation should be active.
1.3.6.1.4.1.4515.1.8.1.1.1.6ColumnxpdrServiceTyperead-writecurrentThe service type of the transponder.
1.3.6.1.4.1.4515.1.8.1.1.1.7ColumnxpdrConnAddMaskread-writecurrentThis object is a bit mask relevant only for Muxponder entry. It contains a bit for each Muxponder service. To add a service the management should set the corre…
1.3.6.1.4.1.4515.1.8.1.1.1.8ColumnxpdrMuxInbandAdminread-writecurrentThis object is relevant only for muxponder. up value means that the muxponder inband management is enabled.
1.3.6.1.4.1.4515.1.8.1.1.1.9ColumnxpdrMuxInbandOperread-onlycurrentThe operational state of the inband interface.
1.3.6.1.4.1.4515.1.8.1.1.1.10ColumnxpdrDirectionread-writecurrentThis object is used for unidirectional services. The upper port is the uplink as with the aps configuration. The transponder on one side should be configured a…
1.3.6.1.4.1.4515.1.8.1.1.1.11ColumnxpdrConnConfigCpriRateControlread-writecurrentThis object is used to detrmine if the CPRI rate control should be active.
1.3.6.1.4.1.4515.1.8.1.1.1.12ColumnxpdrFaultPropagationDelayread-writecurrentThis object is used to determine the fault propagation delay. The value 0 mean no delay, the value 1 means 100ms delay, the value 2 means 200ms delay etc. 0 is…
1.3.6.1.4.1.4515.1.8.1.1.1.13ColumnxpdrFecModeread-writecurrentThis object is used to determine the IEEE FEC mode for 10G and 16G services: 0 - No FEC (default) 1 - FEC Monitoring 2 - FEC Generation 3 - FEC Regeneration
1.3.6.1.4.1.4515.1.8.1.2TableoduXcConnConfigTablenot-accessiblecurrentDescription: 1. The port numbers are: 0 unassigned 1..10 ODUs of Uplink 1 11..20 ODUs of Uplink 2 (not available without 20G or 1+1 license) 2. All connections…
1.3.6.1.4.1.4515.1.8.1.2.1RowoduXcConnConfigEntrynot-accessiblecurrentAn entry in the ODU connection table. An entry describes uni-directional connection of traffic from P1 (Source port) to port P2 (Sync port).
1.3.6.1.4.1.4515.1.8.1.2.1.1ColumnoduXcConnConfigP1read-createcurrentThe Source port.
1.3.6.1.4.1.4515.1.8.1.2.1.2ColumnoduXcConnConfigP2read-createcurrentThe Sync port.
1.3.6.1.4.1.4515.1.8.1.2.1.3ColumnoduXcConnConfigProtectedread-createcurrentIndication for entry with Protection Mates
1.3.6.1.4.1.4515.1.8.1.2.1.4ColumnoduXcConnConfigRowStatusread-createcurrentThe Status of this connection entry.
1.3.6.1.4.1.4515.1.8.1.3ScalarxpdrOduMappingStatusread-onlycurrentA bit mask that specifies how the ODUs are configured. The first nible describes Uplink 1 and the second nibble describes Uplink 2. Examples: If bit 1 equals 1…
1.3.6.1.4.1.4515.1.8.1.4ScalarxpdrOduMappingMaskedAdminread-writecurrentThe first byte is the new mapping to set. The second byte is the mask for the setting. For example to split the second ODU1 of Uplink 1 into two ODU0 First byt…
1.3.6.1.4.1.4515.1.8.6NodeslXpdrLastChange
1.3.6.1.4.1.4515.1.8.7NodeslXpdrTraps
1.3.6.1.4.1.4515.1.8.7.0NodeslXpdrTraps0
1.3.6.1.4.1.4515.1.8.7.0.1NotificationxpdrConnConfigTableChange0currentA xpdrConnConfigTableChange trap is sent when the content of the xpdrConnConfigTable is changed. It is defined to support browsers that don't recognize RFC 257…
1.3.6.1.4.1.4515.1.8.7.1NotificationxpdrConnConfigTableChangecurrentA xpdrConnConfigTableChange trap is sent when the content of the xpdrConnConfigTable is changed.
Type Definitions
NameSyntaxStatusDescription
XpdrServiceTypeINTEGER { ds3Sts1(1), fe(2), escon(3), dvbVideo(4), fc1gFicon(5), gbE(6), fc2g(7), oc3Stm1(8), oc12Stm4(9), oc48Stm16(10), other(11), fc4g(12), infiniband25G(13), otn27g(14), oc24gpon(15), smpteSdi(16), copperFe(17), copperGbe(18), mux2GbE(19), mux4GbE(20), xpdr5G(21), ficon1g(22), ficon2g(23), stm1(24), stm4(25), stm16(26), gpon248(27), ficon4g(28), eth10m(29), xfp10oc192(30), xfp10stm64(31), xfp10GbEWan(32), xfp10GbELan(33), xfp10otu2(34), xfp10GFC(35), xfp10GbEWanStm64(36), mux1GbE(37), mux1GbERegen(38), mux2GbERegen(39), mux4GbERegen(40), fc8g(41), ficon8g(42), mux10GbE(43), syncEgbE(44), otu1e(50), otu2e(51), otu1f(52), otu2f(53), oc192ToOtu2(54), stm64ToOtu2(55), gbe10WanToOtu2(56), gbe10LanToOtu2A(57), gbe10LanToOtu1e(58), gbe10LanToOtu2e(59), gbe10LanToOtu2B(60), fc10LanToOtu1f(61), fc10LanToOtu2f(62), fc8LanToOtu2(63), otu3(64), oc768(65), stm256(66), otu4(67), gbe40lan(68), gbe100lan(69), fc16g(70), smpteHdSdi(71), smpteSdSdi(72), smpte3gSdi(73), smpte3dSdi(74), smpteHdSdiNtsc(75), smpte3gSdiNtsc(76), fc16gNoIsl(77), cpri1(81), cpri2(82), cpri3(83), cpri4(84), cpri5(85), cpri6(86), cpri7(87), enc10GbELan(91), enc1GbELan(92), encfc1g(93), encfc2g(94), encfc4g(95), encfc8g(96), encfc16g(97), encfc10g(98), copper10m(170), copper10mAn(171), copperFeAn(1701) }currentThe service type of the tarsponder.