MIB Viewer

SLE-MPLS-TP-TUNNEL-MIB

68 objects
Copyright (C) The Internet Society (2004). The initial version of this MIB module was published in RFC 3812. For full legal notices see the RFC itself or see: http://www.ietf.org/copyrights/ianamib.html This MIB module contains managed object definitions for MPLS Traffic Engineering (TE) as defined in: 1. Extensions to RSVP for LSP Tunnels, Awduche et al, RFC 3209, December 2001 2. Constraint-Based LSP Setup using LDP, Jamoussi (Editor), RFC 3212, January 2002 3. Requirements for Traffic Engineering Over MPLS, Awduche, D., Malcolm, J., Agogbua, J., O'Dell, M., and J. McManus, [RFC2702], September 1999
OIDNameAccessStatusDescription
1.3.6.1.4.1.6296.101.16IdentitysleMplscurrentSLE MPLS.
1.3.6.1.4.1.6296.101.16.14IdentitysleMplsTpTunnelCopyright (C) The Internet Society (2004). The initial version of this MIB module was published in RFC 3812. For full legal notices see the RFC itself or see: …
1.3.6.1.4.1.6296.101.16.14.1NodesleMplsTpTunnelCfg
1.3.6.1.4.1.6296.101.16.14.1.1TablesleMplsTpTunnelCfgInfoTablenot-accessiblecurrentThe mplsTunnelTable allows new MPLS tunnels to be created between an LSR and a remote endpoint, and existing tunnels to be reconfigured or removed. Note that o…
1.3.6.1.4.1.6296.101.16.14.1.1.1RowsleMplsTpTunnelCfgInfoEntrynot-accessiblecurrentAn entry in this table represents an MPLS tunnel. An entry can be created by a network administrator or by an SNMP agent as instructed by an MPLS signalling pr…
1.3.6.1.4.1.6296.101.16.14.1.1.1.1ColumnsleMplsTpTunnelCfgInfoIndexnot-accessiblecurrentA unique value which identify an entry in this table.
1.3.6.1.4.1.6296.101.16.14.1.1.1.2ColumnsleMplsTpTunnelCfgInfoNameread-onlycurrentThe canonical name assigned to the tunnel. This name can be used to refer to the tunnel on the LSR's console port. If mplsTunnelIsIf is set to true then the if…
1.3.6.1.4.1.6296.101.16.14.1.1.1.3ColumnsleMplsTpTunnelCfgInfoIdread-onlycurrentUniquely identifies a set of tunnel instances between a pair of ingress and egress LSRs. Managers should obtain new values for row creation in this table by re…
1.3.6.1.4.1.6296.101.16.14.1.1.1.4ColumnsleMplsTpTunnelCfgInfoSrcIdTyperead-onlycurrentThis object is used to set the ietf or itut type.
1.3.6.1.4.1.6296.101.16.14.1.1.1.5ColumnsleMplsTpTunnelCfgInfoSrcGIdread-onlycurrentThis Object is used to display the GlobalID of IETF
1.3.6.1.4.1.6296.101.16.14.1.1.1.6ColumnsleMplsTpTunnelCfgInfoSrcCcread-onlycurrentThis Object is used to display the Source CC-ID of ITUT
1.3.6.1.4.1.6296.101.16.14.1.1.1.7ColumnsleMplsTpTunnelCfgInfoSrcIccread-onlycurrentThis Object is used to set the Source ICC-ID of ITUT
1.3.6.1.4.1.6296.101.16.14.1.1.1.8ColumnsleMplsTpTunnelCfgInfoSrcNodeIdread-onlycurrentThis Object is used to display the Source Node ID of IETF and ITUT
1.3.6.1.4.1.6296.101.16.14.1.1.1.9ColumnsleMplsTpTunnelCfgInfoDestIdTyperead-onlycurrentThis object is used to set the ietf or itut type.
1.3.6.1.4.1.6296.101.16.14.1.1.1.10ColumnsleMplsTpTunnelCfgInfoDestGIdread-onlycurrentThis Object is used to set the Destination GlobalID of IETF
1.3.6.1.4.1.6296.101.16.14.1.1.1.11ColumnsleMplsTpTunnelCfgInfoDestCcread-onlycurrentThis Object is used to display the Destination CC-ID of ITUT
1.3.6.1.4.1.6296.101.16.14.1.1.1.12ColumnsleMplsTpTunnelCfgInfoDestIccread-onlycurrentThis Object is used to set the Destination ICC-ID of ITUT
1.3.6.1.4.1.6296.101.16.14.1.1.1.13ColumnsleMplsTpTunnelCfgInfoDestNodeIdread-onlycurrentThis Object is used to display the Destination Node ID of IETF and ITUT
1.3.6.1.4.1.6296.101.16.14.1.1.1.14ColumnsleMplsTpTunnelCfgInfoModeread-onlycurrentThis object is used to set the Tunnel Mode
1.3.6.1.4.1.6296.101.16.14.1.1.1.15ColumnsleMplsTpTunnelCfgInfoFwdInLabelread-onlycurrentThis object is used to display the Forward In Label. The lable range is 0 to 1048575. Here 0 to 15 are reserved labels. User allowed range is 16 to 1048575.. T…
1.3.6.1.4.1.6296.101.16.14.1.1.1.16ColumnsleMplsTpTunnelCfgInfoFwdInIfIndexread-onlycurrentThis object is used to set the Forward IN Interface index
1.3.6.1.4.1.6296.101.16.14.1.1.1.17ColumnsleMplsTpTunnelCfgInfoFwdOperationread-onlycurrentThis object is used to set the Forward Ilm OPeration .
1.3.6.1.4.1.6296.101.16.14.1.1.1.18ColumnsleMplsTpTunnelCfgInfoFwdOutLabelread-onlycurrentThis object is used to display the Forward In Label. The lable range is 0 to 1048575. Here 0 to 15 are reserved labels. User allowed range is 16 to 1048575. Th…
1.3.6.1.4.1.6296.101.16.14.1.1.1.19ColumnsleMplsTpTunnelCfgInfoFwdOutIfIndexread-onlycurrentThis object is used to set the Forward OUT Interface index
1.3.6.1.4.1.6296.101.16.14.1.1.1.20ColumnsleMplsTpTunnelCfgInfoFwdOutMacread-onlycurrentThis object is used to display the Forward OUT MAC ADDRESS
1.3.6.1.4.1.6296.101.16.14.1.1.1.21ColumnsleMplsTpTunnelCfgInfoRevInLabelread-onlycurrentThis object is used to display the Forward In Label. The lable range is 0 to 1048575. Here 0 to 15 are reserved labels. User allowed range is 16 to 1048575. Th…
1.3.6.1.4.1.6296.101.16.14.1.1.1.22ColumnsleMplsTpTunnelCfgInfoRevInIfIndexread-onlycurrentThis object is used to set the Reverse IN Interface index
1.3.6.1.4.1.6296.101.16.14.1.1.1.23ColumnsleMplsTpTunnelCfgInfoRevOperationread-onlycurrentThis object is used to set the Reverse Ilm OPeration .
1.3.6.1.4.1.6296.101.16.14.1.1.1.24ColumnsleMplsTpTunnelCfgInfoRevOutLabelread-onlycurrentThis object is used to display the Forward In Label. The lable range is 0 to 1048575. Here 0 to 15 are reserved labels. User allowed range is 16 to 1048575. Th…
1.3.6.1.4.1.6296.101.16.14.1.1.1.25ColumnsleMplsTpTunnelCfgInfoRevOutIfIndexread-onlycurrentThis object is used to set the Reverse OUT Interface index
1.3.6.1.4.1.6296.101.16.14.1.1.1.26ColumnsleMplsTpTunnelCfgInfoRevOutMacread-onlycurrentThis object is used to display the Forward OUT MAC ADDRESS .
1.3.6.1.4.1.6296.101.16.14.1.1.1.27ColumnsleMplsTpTunnelCfgInfoStateread-onlycurrentThis object is to display status of the tunnel.
1.3.6.1.4.1.6296.101.16.14.1.1.1.28ColumnsleMplsTpTunnelCfgInfoRoleread-onlycurrentThis object is to display Role of the tunnel.
1.3.6.1.4.1.6296.101.16.14.1.1.1.29ColumnsleMplsTpTunnelCfgInfoAssociateTnlNameread-onlycurrentThis object to display associate of reverse tunnel.
1.3.6.1.4.1.6296.101.16.14.1.1.1.30ColumnsleMplsTpTunnelCfgInfoDescriptionread-onlycurrentDescription.
1.3.6.1.4.1.6296.101.16.14.1.1.1.31ColumnsleMplsTpTunnelCfgInfoHlspRoleread-onlycurrentThis object is used to set the Hlsp Tunnel. whether the tunnel is Server or client. server (1) :- To set the Server Tunnel client(2) :- To set the Client Tunne…
1.3.6.1.4.1.6296.101.16.14.1.1.1.32ColumnsleMplsTpTunnelCfgInfoHlspServerTunnelNameread-onlycurrentThis object is used to set the server TunnelName, when sleMplsTpTunnelCfgControlHlspOption as a client .
1.3.6.1.4.1.6296.101.16.14.1.1.1.33ColumnsleMplsTpTunnelCfgInfoQosPolicyNameread-onlycurrentThis object is used to set the Qos Policy name.
1.3.6.1.4.1.6296.101.16.14.1.2NodesleMplsTpTunnelCfgControl
1.3.6.1.4.1.6296.101.16.14.1.2.1ScalarsleMplsTpTunnelCfgControlRequestread-writecurrentThis object holds the possible read-write columns that can be modified in the Tunnel table. For each read-write column of Tunnel table, a Set Operation control…
1.3.6.1.4.1.6296.101.16.14.1.2.2ScalarsleMplsTpTunnelCfgControlStatusread-onlycurrentThis object displays the status of the configuration done.
1.3.6.1.4.1.6296.101.16.14.1.2.3ScalarsleMplsTpTunnelCfgControlTimerread-writecurrentThis object is based on the SLE style where a timer is configured for every control table.
1.3.6.1.4.1.6296.101.16.14.1.2.4ScalarsleMplsTpTunnelCfgControlTimeStampread-onlycurrentThis object specifies the time at which the configuration is done.
1.3.6.1.4.1.6296.101.16.14.1.2.5ScalarsleMplsTpTunnelCfgControlReqResultread-onlycurrentThe standard result of the SET operation is stored here.
1.3.6.1.4.1.6296.101.16.14.1.2.6ScalarsleMplsTpTunnelCfgControlNameread-writecurrentThe canonical name assigned to the tunnel. This name can be used to refer to the tunnel on the LSR's console port. If mplsTunnelIsIf is set to true then the if…
1.3.6.1.4.1.6296.101.16.14.1.2.7ScalarsleMplsTpTunnelCfgControlIdread-writecurrentThis object is used to set the tunnel Id .
1.3.6.1.4.1.6296.101.16.14.1.2.8ScalarsleMplsTpTunnelCfgControlSrcIdTyperead-writecurrentThis object is used to set the ietf or itut type.
1.3.6.1.4.1.6296.101.16.14.1.2.9ScalarsleMplsTpTunnelCfgControlSrcGIdread-writecurrentThis object is used to set the source Global-Id for IETF .
1.3.6.1.4.1.6296.101.16.14.1.2.10ScalarsleMplsTpTunnelCfgControlSrcCcread-writecurrentThis object is used to set the source CC-ID for ITUT.
1.3.6.1.4.1.6296.101.16.14.1.2.11ScalarsleMplsTpTunnelCfgControlSrcIccread-writecurrentThis object is used to set the Source ICC-ID for ITUT.
1.3.6.1.4.1.6296.101.16.14.1.2.12ScalarsleMplsTpTunnelCfgControlSrcNodeIdread-writecurrentThis object is used to set the Source Node-Id for IETF and ITUT
1.3.6.1.4.1.6296.101.16.14.1.2.13ScalarsleMplsTpTunnelCfgControlDestIdTyperead-writecurrentThis object is used to set the ietf or itut type.
1.3.6.1.4.1.6296.101.16.14.1.2.14ScalarsleMplsTpTunnelCfgControlDestGIdread-writecurrentThis object is used to set the Destination Global-Id for IETF .
1.3.6.1.4.1.6296.101.16.14.1.2.15ScalarsleMplsTpTunnelCfgControlDestCcread-writecurrentThis object is used to set the Destination CC-ID for ITUT.
1.3.6.1.4.1.6296.101.16.14.1.2.16ScalarsleMplsTpTunnelCfgControlDestIccread-writecurrentThis object is used to set the Destination ICC-ID for ITUT.
1.3.6.1.4.1.6296.101.16.14.1.2.17ScalarsleMplsTpTunnelCfgControlDestNodeIdread-writecurrentThis object is used to set the Destination NodeID for IETF and ITUT.
1.3.6.1.4.1.6296.101.16.14.1.2.18ScalarsleMplsTpTunnelCfgControlModeread-writecurrentThis object is used to set the Tunnel mode .
1.3.6.1.4.1.6296.101.16.14.1.2.19ScalarsleMplsTpTunnelCfgControlPathread-writecurrentThis object is used to Set the forward path and reverse path tunnel.
1.3.6.1.4.1.6296.101.16.14.1.2.20ScalarsleMplsTpTunnelCfgControlInLabelread-writecurrentThis object is used to set the Inlabel.
1.3.6.1.4.1.6296.101.16.14.1.2.21ScalarsleMplsTpTunnelCfgControlInInterfaceread-writecurrentThis object is used to set the Ininterface index.
1.3.6.1.4.1.6296.101.16.14.1.2.22ScalarsleMplsTpTunnelCfgControlOperationread-writecurrentThis object is used to set the operation of Tuunel
1.3.6.1.4.1.6296.101.16.14.1.2.23ScalarsleMplsTpTunnelCfgControlOutLabelread-writecurrentThis object is used to set the outlabel.
1.3.6.1.4.1.6296.101.16.14.1.2.24ScalarsleMplsTpTunnelCfgControlOutInterfaceread-writecurrentThis object is used to set the outerinterface index.
1.3.6.1.4.1.6296.101.16.14.1.2.25ScalarsleMplsTpTunnelCfgControlOutMacAddressread-writecurrentThis object is used to Set the Out MacAddress .
1.3.6.1.4.1.6296.101.16.14.1.2.26ScalarsleMplsTpTunnelCfgControlAssociateTnlNameread-writecurrentThis object is used to Associated Forward tunnel and reverse tunnel with reverse tunnel name .
1.3.6.1.4.1.6296.101.16.14.1.2.27ScalarsleMplsTpTunnelCfgControlDescriptionread-writecurrentDescription.
1.3.6.1.4.1.6296.101.16.14.1.2.28ScalarsleMplsTpTunnelCfgControlHlspSeverTunnelNameread-writecurrentThis object is used to set the server Tunnel name for associating server and client.
1.3.6.1.4.1.6296.101.16.14.1.2.29ScalarsleMplsTpTunnelCfgControlQosPolicyNameread-writecurrentThis object is used to set the Qos Policy name.