SMART-PDUATS-MIB

173 objects
MIB file for the PDU (Power Distribution Unit) equipments.
Imported Objects
SNMPv2-SMIenterprises Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
SNMPv2-TCDisplayString TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.55508Identitysmart-PDUMIB file for the PDU (Power Distribution Unit) equipments.
1.3.6.1.4.1.55508.1NodepduAts
1.3.6.1.4.1.55508.1.1Nodesystem
1.3.6.1.4.1.55508.1.1.1NodeeventInfo
1.3.6.1.4.1.55508.1.1.1.1ScalarsourceIDread-onlycurrentThe ID (address code) of sources(PDU/ATS/SENSOR). The OID is bound in a trap message.
1.3.6.1.4.1.55508.1.1.1.2ScalarpowerDescrread-onlycurrentThe description to source PDU/ATS. The OID is bound in a trap message.
1.3.6.1.4.1.55508.1.1.1.3ScalareventSourceread-onlycurrentThe event sources: PDU(fuse/load), ATS(switching/voltage), SENSOR(temp./humid./wind/environment). The OID is bound in a trap message.
1.3.6.1.4.1.55508.1.1.1.4ScalarsensorDescrread-onlycurrentThe description to source SENSOR. The OID is bound in a trap message.
1.3.6.1.4.1.55508.1.1.1.5ScalareventTyperead-onlycurrentThe type of the event (trap). The value would be 'recovery' or 'alarm' or 'notify'. 'recovery': An alarm is recovery. 'alarm': An alarm is issued or repeated. …
1.3.6.1.4.1.55508.1.1.1.6ScalareventDateTimeread-onlycurrentAlert time. The OID is bound in a trap message.
1.3.6.1.4.1.55508.1.1.1.7ScalarloadValueread-onlycurrentThe load value of OUTLET/TOTAL. A non-negative value indicates the measured load in tenth of amperes. A negative value indicates that a load value was not avai…
1.3.6.1.4.1.55508.1.1.1.8ScalarloadLowValueread-onlycurrentThe setting of low limit of load of OUTLET/TOTAL. A non-negative value indicates the measured load in tenth of amperes. A negative value indicates that a load …
1.3.6.1.4.1.55508.1.1.1.9ScalarloadHighValueread-onlycurrentThe setting of high limit of load of OUTLET/TOTAL. A non-negative value indicates the measured load in tenth of amperes. A negative value indicates that a load…
1.3.6.1.4.1.55508.1.1.1.10ScalarvoltageValueread-onlycurrentThe voltage value of input. A non-negative value indicates the measured value in volts. A negative value indicates that a value was not available. The OID is b…
1.3.6.1.4.1.55508.1.1.1.11ScalarvoltageLowValueread-onlycurrentThe setting of low limit of voltage of input. A non-negative value indicates the measured value in volts. A negative value indicates that a value was not avail…
1.3.6.1.4.1.55508.1.1.1.12ScalarvoltageHighValueread-onlycurrentThe setting of high limit of voltage of input. A non-negative value indicates the measured value in volts. A negative value indicates that a value was not avai…
1.3.6.1.4.1.55508.1.1.2NodesysNetwork
1.3.6.1.4.1.55508.1.1.2.1ScalaripAddressread-writecurrentThe IP address of this management node where this SNMP agent is running(Default value: 192.168.0.254). NOTATION: When ipAddress is changed, the IP address of t…
1.3.6.1.4.1.55508.1.1.2.2ScalarmaskIpAddressread-writecurrentThe mask IP address,default value: 255.255.255.0 NOTATION: When changed, this equipment should be reboot to take effect.
1.3.6.1.4.1.55508.1.1.2.3ScalargatewayIpAddressread-writecurrentThe gateway IP address,default value: 0.0.0.0 NOTATION: When changed, this equipment should be reboot to take effect.
1.3.6.1.4.1.55508.1.1.2.4ScalardnsIpAddress1read-writecurrentThe DNS#1 IP address,default value: 0.0.0.0 NOTATION: When changed, this equipment should be reboot to take effect.
1.3.6.1.4.1.55508.1.1.2.5ScalardnsIpAddress2read-writecurrentThe DNS#2 IP address,default value: 0.0.0.0 NOTATION: When changed, this equipment should be reboot to take effect.
1.3.6.1.4.1.55508.1.1.2.6ScalarrebootSystemread-writecurrentSet value 1 to the OID to reboot the system. set value 0 would not be allowed. WARNING: TAKE CARE BEFORE SET!
1.3.6.1.4.1.55508.1.1.2.7ScalartrapDestIP1read-writecurrentThe trap destination IP address #1,default value: 0.0.0.0
1.3.6.1.4.1.55508.1.1.2.8ScalartrapDestIP2read-writecurrentThe trap destination IP address #2,default value: 0.0.0.0
1.3.6.1.4.1.55508.1.1.2.9ScalartrapDestIP3read-writecurrentThe trap destination IP address #3,default value: 0.0.0.0
1.3.6.1.4.1.55508.1.1.2.10ScalartrapDestIP4read-writecurrentThe trap destination IP address #2,default value: 0.0.0.0
1.3.6.1.4.1.55508.1.2NodepowerTables
1.3.6.1.4.1.55508.1.2.1Tablepower1OutletTablenot-accessiblecurrentA table list the status of all outlets.
1.3.6.1.4.1.55508.1.2.1.1Rowpower1OutletEntrynot-accessiblecurrentRow definition for the status list.
1.3.6.1.4.1.55508.1.2.1.1.1Columnp1OutletSeqread-onlycurrentSequence of table.
1.3.6.1.4.1.55508.1.2.1.1.2Columnp1OutletNoread-onlycurrentOutlet's No.
1.3.6.1.4.1.55508.1.2.1.1.3Columnp1OutletDescread-writecurrentOutlet's description.
1.3.6.1.4.1.55508.1.2.1.1.4Columnp1OutletSocketread-onlycurrentOutlet's socket standard description.
1.3.6.1.4.1.55508.1.2.1.1.5Columnp1OutletFuseread-onlycurrentOutlet's fuse status. Normal or Alarm.
1.3.6.1.4.1.55508.1.2.1.1.6Columnp1OutletOnOffread-writecurrentOutlet's ON/OFF status.
1.3.6.1.4.1.55508.1.2.1.1.7Columnp1OutletLoadread-onlycurrentOutlet's load amperes. A non-negative value indicates the measured load in tenth of amperes. A negative value indicates that a load value was not available.
1.3.6.1.4.1.55508.1.2.1.1.8Columnp1OutletLoadLowLimitread-writecurrentOutlet's load low-limit in amperes. A non-negative value indicates the measured load in tenth of amperes. A negative value indicates that a load value was not …
1.3.6.1.4.1.55508.1.2.1.1.9Columnp1OutletLoadHighLimitread-writecurrentOutlet's load high-limit in amperes. A non-negative value indicates the measured load in tenth of amperes. A negative value indicates that a load value was not…
1.3.6.1.4.1.55508.1.2.1.1.10Columnp1OutletEnergyread-onlycurrentOutlet's energy (unit in 0.01kWh). A non-negative value indicates the measured energy hundredth of kWh. A negative value indicates that the energy value was no…
1.3.6.1.4.1.55508.1.2.1.1.11Columnp1Powerread-onlycurrentOutlet's active power (unit in 0.01W). A non-negative value indicates the measured active power hundredth of W. A negative value indicates that the active powe…
1.3.6.1.4.1.55508.1.2.1.1.12Columnp1PowerFactorread-onlycurrentOutlet's power factor (unit in 0.01). A non-negative value indicates the measured power factor hundredth. A negative value indicates that the power factor valu…
1.3.6.1.4.1.55508.1.2.2Tablepower2OutletTablenot-accessiblecurrentA table list the status of all outlets.
1.3.6.1.4.1.55508.1.2.2.1Rowpower2OutletEntrynot-accessiblecurrentRow definition for the status list.
1.3.6.1.4.1.55508.1.2.2.1.1Columnp2OutletSeqread-onlycurrentSequence of table.
1.3.6.1.4.1.55508.1.2.2.1.2Columnp2OutletNoread-onlycurrentOutlet's No.
1.3.6.1.4.1.55508.1.2.2.1.3Columnp2OutletDescread-writecurrentOutlet's description.
1.3.6.1.4.1.55508.1.2.2.1.4Columnp2OutletSocketread-onlycurrentOutlet's socket standard description.
1.3.6.1.4.1.55508.1.2.2.1.5Columnp2OutletFuseread-onlycurrentOutlet's fuse status. Normal or Alarm.
1.3.6.1.4.1.55508.1.2.2.1.6Columnp2OutletOnOffread-writecurrentOutlet's ON/OFF status.
1.3.6.1.4.1.55508.1.2.2.1.7Columnp2OutletLoadread-onlycurrentOutlet's load amperes. A non-negative value indicates the measured load in tenth of amperes. A negative value indicates that a load value was not available.
1.3.6.1.4.1.55508.1.2.2.1.8Columnp2OutletLoadLowLimitread-writecurrentOutlet's load low-limit in amperes. A non-negative value indicates the measured load in tenth of amperes. A negative value indicates that a load value was not …
1.3.6.1.4.1.55508.1.2.2.1.9Columnp2OutletLoadHighLimitread-writecurrentOutlet's load high-limit in amperes. A non-negative value indicates the measured load in tenth of amperes. A negative value indicates that a load value was not…
1.3.6.1.4.1.55508.1.2.2.1.10Columnp2OutletEnergyread-onlycurrentOutlet's energy (unit in 0.01kWh). A non-negative value indicates the measured energy hundredth of kWh. A negative value indicates that the energy value was no…
1.3.6.1.4.1.55508.1.2.2.1.11Columnp2Powerread-onlycurrentOutlet's active power (unit in 0.01W). A non-negative value indicates the measured active power hundredth of W. A negative value indicates that the active powe…
1.3.6.1.4.1.55508.1.2.2.1.12Columnp2PowerFactorread-onlycurrentOutlet's power factor (unit in 0.01). A non-negative value indicates the measured power factor hundredth. A negative value indicates that the power factor valu…
1.3.6.1.4.1.55508.1.2.3Tablepower3OutletTablenot-accessiblecurrentA table list the status of all outlets.
1.3.6.1.4.1.55508.1.2.3.1Rowpower3OutletEntrynot-accessiblecurrentRow definition for the status list.
1.3.6.1.4.1.55508.1.2.3.1.1Columnp3OutletSeqread-onlycurrentSequence of table.
1.3.6.1.4.1.55508.1.2.3.1.2Columnp3OutletNoread-onlycurrentOutlet's No.
1.3.6.1.4.1.55508.1.2.3.1.3Columnp3OutletDescread-writecurrentOutlet's description.
1.3.6.1.4.1.55508.1.2.3.1.4Columnp3OutletSocketread-onlycurrentOutlet's socket standard description.
1.3.6.1.4.1.55508.1.2.3.1.5Columnp3OutletFuseread-onlycurrentOutlet's fuse status. Normal or Alarm.
1.3.6.1.4.1.55508.1.2.3.1.6Columnp3OutletOnOffread-writecurrentOutlet's ON/OFF status.
1.3.6.1.4.1.55508.1.2.3.1.7Columnp3OutletLoadread-onlycurrentOutlet's load amperes. A non-negative value indicates the measured load in tenth of amperes. A negative value indicates that a load value was not available.
1.3.6.1.4.1.55508.1.2.3.1.8Columnp3OutletLoadLowLimitread-writecurrentOutlet's load low-limit in amperes. A non-negative value indicates the measured load in tenth of amperes. A negative value indicates that a load value was not …
1.3.6.1.4.1.55508.1.2.3.1.9Columnp3OutletLoadHighLimitread-writecurrentOutlet's load high-limit in amperes. A non-negative value indicates the measured load in tenth of amperes. A negative value indicates that a load value was not…
1.3.6.1.4.1.55508.1.2.3.1.10Columnp3OutletEnergyread-onlycurrentOutlet's energy (unit in 0.01kWh). A non-negative value indicates the measured energy hundredth of kWh. A negative value indicates that the energy value was no…
1.3.6.1.4.1.55508.1.2.3.1.11Columnp3Powerread-onlycurrentOutlet's active power (unit in 0.01W). A non-negative value indicates the measured active power hundredth of W. A negative value indicates that the active powe…
1.3.6.1.4.1.55508.1.2.3.1.12Columnp3PowerFactorread-onlycurrentOutlet's power factor (unit in 0.01). A non-negative value indicates the measured power factor hundredth. A negative value indicates that the power factor valu…
1.3.6.1.4.1.55508.1.2.4TablepowerBranchTablenot-accessiblecurrentA table list the status of all branchs.
1.3.6.1.4.1.55508.1.2.4.1RowpowerBranchEntrynot-accessiblecurrentRow definition for the status list.
1.3.6.1.4.1.55508.1.2.4.1.1ColumnbranchSeqread-onlycurrentSequence of table.
1.3.6.1.4.1.55508.1.2.4.1.2ColumnbranchRateread-onlycurrentBranch rated current (unit in 0.01A). A non-negative value indicates the measured load in hundredth of amperes. A negative value indicates that a load value wa…
1.3.6.1.4.1.55508.1.2.4.1.3ColumnbranchVoltageread-onlycurrentThe voltage of branch (unit in 0.1V). A non-negative value indicates the measured voltage in tenth of volts. A negative value indicates that a voltage value wa…
1.3.6.1.4.1.55508.1.2.4.1.4ColumnbranchEnergyread-onlycurrentThe energy of branch (unit in 0.1kWh). A non-negative value indicates the measured energy tenth of kWh. A negative value indicates that the energy value was no…
1.3.6.1.4.1.55508.1.2.4.1.5ColumnbranchPowerread-onlycurrentThe active power of branch (unit in W). A non-negative value indicates the measured active power. A negative value indicates that the active power value was no…
1.3.6.1.4.1.55508.1.2.4.1.6ColumnbranchPowerFactorread-onlycurrentThe power factor of branch (unit in 0.01). A non-negative value indicates the measured power factor hundredth. A negative value indicates that the power factor…
1.3.6.1.4.1.55508.1.2.4.1.7ColumnbranchLoadread-onlycurrentThe load of branch (unit in 0.01A). A non-negative value indicates the measured load in hundredth of amperes. A negative value indicates that a load value was …
1.3.6.1.4.1.55508.1.2.4.1.8ColumnbranchLoadHighLimitread-writecurrentBranch's load high-limit in amperes. A non-negative value indicates the measured load in hundredth of amperes. A negative value indicates that a load value was…
1.3.6.1.4.1.55508.1.2.4.1.9ColumnbranchNoread-onlycurrentBranch's No.
1.3.6.1.4.1.55508.1.2.4.1.10ColumnbranchBreakerread-onlycurrentBreaker's status.
1.3.6.1.4.1.55508.1.2.5TablepowerSummaryTablenot-accessiblecurrentA table list the summary status information for PDU.
1.3.6.1.4.1.55508.1.2.5.1RowpowerSummaryEntrynot-accessiblecurrentRow definition for the status list.
1.3.6.1.4.1.55508.1.2.5.1.1ColumnpowerSeqread-onlycurrentSequence of table.
1.3.6.1.4.1.55508.1.2.5.1.2ColumnpowerIDread-onlycurrentOutlet's No.
1.3.6.1.4.1.55508.1.2.5.1.3ColumnpowerNameread-writecurrentThe PDU description.
1.3.6.1.4.1.55508.1.2.5.1.4ColumnpowerTyperead-onlycurrentThe PDU type.
1.3.6.1.4.1.55508.1.2.5.1.5ColumnpowerModelread-onlycurrentThe PDU type.
1.3.6.1.4.1.55508.1.2.5.1.6ColumnpowerOnGapread-writecurrentThe interval of outlets' of the PDU when power on.
1.3.6.1.4.1.55508.1.2.5.1.7ColumntotalLoadAread-onlycurrentThe A total load of the PDU when it is Three-phase input, or the total load of the PDU when it is Single-phase input. A non-negative value indicates the measur…
1.3.6.1.4.1.55508.1.2.5.1.8ColumntotalLoadALowLimitread-writecurrentThe A total load low limit of the PDU when it is Three-phase input, or the total load of the PDU when it is Single-phase input. A non-negative value indicates …
1.3.6.1.4.1.55508.1.2.5.1.9ColumntotalLoadAHighLimitread-writecurrentThe A total load high limit of the PDU when it is Three-phase input, or the total load of the PDU when it is Single-phase input. A non-negative value indicates…
1.3.6.1.4.1.55508.1.2.5.1.10ColumntotalLoadBread-onlycurrentThe B total load of the PDU when it is Three-phase input. A non-negative value indicates the measured load in tenth of amperes. A negative value indicates that…
1.3.6.1.4.1.55508.1.2.5.1.11ColumntotalLoadBLowLimitread-writecurrentThe B total load low limit of the PDU when it is Three-phase input, A non-negative value indicates the measured load in tenth of amperes. A negative value indi…
1.3.6.1.4.1.55508.1.2.5.1.12ColumntotalLoadBHighLimitread-writecurrentThe B total load high limit of the PDU when it is Three-phase input, A non-negative value indicates the measured load in tenth of amperes. A negative value ind…
1.3.6.1.4.1.55508.1.2.5.1.13ColumntotalLoadCread-onlycurrentThe C total load of the PDU when it is Three-phase input, A non-negative value indicates the measured load in tenth of amperes. A negative value indicates that…
1.3.6.1.4.1.55508.1.2.5.1.14ColumntotalLoadCLowLimitread-writecurrentThe C total load low limit of the PDU when it is Three-phase input, A non-negative value indicates the measured load in tenth of amperes. A negative value indi…
1.3.6.1.4.1.55508.1.2.5.1.15ColumntotalLoadCHighLimitread-writecurrentThe C total load high limit of the PDU when it is Three-phase input, A non-negative value indicates the measured load in tenth of amperes. A negative value ind…
1.3.6.1.4.1.55508.1.2.5.1.16ColumnvoltageAread-onlycurrentThe A voltage of the PDU when it is Three-phase input, or the voltage of the PDU when it is Single-phase input, A non-negative value indicates the measured val…
1.3.6.1.4.1.55508.1.2.5.1.17ColumnvoltageBread-onlycurrentThe B voltage of the PDU when it is Three-phase input, A non-negative value indicates the measured value in volts. A negative value indicates that a value was …
1.3.6.1.4.1.55508.1.2.5.1.18ColumnvoltageCread-onlycurrentThe C voltage of the PDU when it is Three-phase input, A non-negative value indicates the measured value in volts. A negative value indicates that a value was …
1.3.6.1.4.1.55508.1.2.5.1.19ColumnpowerEnergyread-onlycurrentThe ACC. energy of the PDU, A non-negative value indicates the measured value in tenth of kWh. A negative value indicates that a value was not available.
1.3.6.1.4.1.55508.1.2.5.1.20ColumnactivePowerAread-onlycurrentThe active power of the input power A. A non-negative value indicates the measured value in tenth of watts. A negative value indicates that a value was not ava…
1.3.6.1.4.1.55508.1.2.5.1.21ColumnratedPowerAread-onlycurrentThe rated power of the input power B. A non-negative value indicates the measured value in tenth of watts. A negative value indicates that a value was not avai…
1.3.6.1.4.1.55508.1.2.5.1.22ColumnremainPowerAread-onlycurrentThe remain power of the input power A. A non-negative value indicates the measured value in tenth of watts. A negative value indicates that a value was not ava…
1.3.6.1.4.1.55508.1.2.5.1.23ColumnapparentPowerAread-onlycurrentThe apparent power of the input power A. A non-negative value indicates the measured value in tenth of W. A negative value indicates that a value was not avail…
1.3.6.1.4.1.55508.1.2.5.1.24ColumnpowerFactorAread-onlycurrentThe power factor of the input power A. A non-negative value indicates the power factor in hundredth. A negative value indicates that the power factor was not a…
1.3.6.1.4.1.55508.1.2.5.1.25ColumnactivePowerBread-onlycurrentThe active power of the input power B. A non-negative value indicates the measured value in tenth of watts. A negative value indicates that a value was not ava…
1.3.6.1.4.1.55508.1.2.5.1.26ColumnratedPowerBread-onlycurrentThe rated power of the input power B. A non-negative value indicates the measured value in tenth of watts. A negative value indicates that a value was not avai…
1.3.6.1.4.1.55508.1.2.5.1.27ColumnremainPowerBread-onlycurrentThe remain power of the input power B. A non-negative value indicates the measured value in tenth of watts. A negative value indicates that a value was not ava…
1.3.6.1.4.1.55508.1.2.5.1.28ColumnapparentPowerBread-onlycurrentThe apparent power of the input power B. A non-negative value indicates the measured value in tenth of W. A negative value indicates that a value was not avail…
1.3.6.1.4.1.55508.1.2.5.1.29ColumnpowerFactorBread-onlycurrentThe power factor of the input power B. A non-negative value indicates the power factor in hundredth. A negative value indicates that the power factor was not a…
1.3.6.1.4.1.55508.1.2.5.1.30ColumnactivePowerCread-onlycurrentThe active power of the input power C. A non-negative value indicates the measured value in tenth of watts. A negative value indicates that a value was not ava…
1.3.6.1.4.1.55508.1.2.5.1.31ColumnratedPowerCread-onlycurrentThe rated power of the input power C. A non-negative value indicates the measured value in tenth of watts. A negative value indicates that a value was not avai…
1.3.6.1.4.1.55508.1.2.5.1.32ColumnremainPowerCread-onlycurrentThe remain power of the input powerC. A non-negative value indicates the measured value in tenth of watts. A negative value indicates that a value was not avai…
1.3.6.1.4.1.55508.1.2.5.1.33ColumnapparentPowerCread-onlycurrentThe apparent power of the input power C. A non-negative value indicates the measured value in tenth of W. A negative value indicates that a value was not avail…
1.3.6.1.4.1.55508.1.2.5.1.34ColumnpowerFactorCread-onlycurrentThe power factor of the input power C. A non-negative value indicates the power factor in hundredth. A negative value indicates that the power factor was not a…
1.3.6.1.4.1.55508.1.2.5.1.35ColumnatsInputread-onlycurrentThe power input of ATS, which would be A or B.
1.3.6.1.4.1.55508.1.2.5.1.36ColumnatsPriorityread-writecurrentThe priority input of ATS.
1.3.6.1.4.1.55508.1.2.5.1.37ColumnatsAVoltageread-onlycurrentThe A voltage of ATS, A non-negative value indicates the measured value in volts. A negative value indicates that a value was not available.
1.3.6.1.4.1.55508.1.2.5.1.38ColumnatsBVoltageread-onlycurrentThe B voltage of ATS, A non-negative value indicates the measured value in volts. A negative value indicates that a value was not available.
1.3.6.1.4.1.55508.1.2.5.1.39ColumnatsAEnergyread-onlycurrentThe A energy of ATS, A non-negative value indicates the measured value in tenth of kWh. A negative value indicates that a value was not available.
1.3.6.1.4.1.55508.1.2.5.1.40ColumnatsBEnergyread-onlycurrentThe B energy of ATS, A non-negative value indicates the measured value in tenth of kWh. A negative value indicates that a value was not available.
1.3.6.1.4.1.55508.1.2.5.1.41ColumnatsSwitchLowread-writecurrentThe switch voltage low-limit of ATS, A non-negative value indicates the measured value in volts. A negative value indicates that a value was not available.
1.3.6.1.4.1.55508.1.2.5.1.42ColumnatsSwitchHighread-writecurrentThe switch voltage high-limit of ATS, A non-negative value indicates the measured value in volts. A negative value indicates that a value was not available.
1.3.6.1.4.1.55508.1.2.5.1.43ColumnatsSwitchTimeread-writecurrentThe switch time of ATS. A non-negative value indicates the measured load in minutes. A negative value indicates that a time value was not available.
1.3.6.1.4.1.55508.1.2.5.1.44ColumnatsSwitchLockread-writecurrentThe switch lock status of ATS.
1.3.6.1.4.1.55508.1.2.5.1.45ColumnatsMonitorread-writecurrentThe stability monitor status of ATS.
1.3.6.1.4.1.55508.1.2.5.1.46ColumnallOutletsSwitchread-writecurrentTo set the switches of all outlets belong to this Power(PDU). A negative value none(-1) would be returned for GET command. Nothing to do when SET with the valu…
1.3.6.1.4.1.55508.1.2.5.1.47Columnfrequencyread-onlycurrentThe frequency value of the input. A non-negative value indicates the measured value in hertz.
1.3.6.1.4.1.55508.1.2.5.1.48ColumnvoltageALowLimitread-writecurrentThe A voltage low limit of the PDU when it is Three-phase input, or the voltage low limit of the PDU when it is Single-phase input. A non-negative value indica…
1.3.6.1.4.1.55508.1.2.5.1.49ColumnvoltageAHighLimitread-writecurrentThe A voltage high limit of the PDU when it is Three-phase input, or the voltage high limit of the PDU when it is Single-phase input. A non-negative value indi…
1.3.6.1.4.1.55508.1.2.5.1.50ColumnvoltageBLowLimitread-writecurrentThe B voltage low limit of the PDU when it is Three-phase input. A non-negative value indicates the measured value in volts. A negative value indicates that a …
1.3.6.1.4.1.55508.1.2.5.1.51ColumnvoltageBHighLimitread-writecurrentThe B voltage high limit of the PDU when it is Three-phase input. A non-negative value indicates the measured value in volts. A negative value indicates that a…
1.3.6.1.4.1.55508.1.2.5.1.52ColumnvoltageCLowLimitread-writecurrentThe C voltage low limit of the PDU when it is Three-phase input. A non-negative value indicates the measured value in volts. A negative value indicates that a …
1.3.6.1.4.1.55508.1.2.5.1.53ColumnvoltageCHighLimitread-writecurrentThe C voltage high limit of the PDU when it is Three-phase input. A non-negative value indicates the measured value in volts. A negative value indicates that a…
1.3.6.1.4.1.55508.1.3NodeenvironmentTable
1.3.6.1.4.1.55508.1.3.1TablesensorTablenot-accessiblecurrentA table list the status of all external sensors.
1.3.6.1.4.1.55508.1.3.1.1RowsensorEntrynot-accessiblecurrentRow definition for the status list.
1.3.6.1.4.1.55508.1.3.1.1.1ColumnsensorSeqread-onlycurrentSequence of table.
1.3.6.1.4.1.55508.1.3.1.1.2ColumnsensorNoread-onlycurrentSensor's No.
1.3.6.1.4.1.55508.1.3.1.1.3ColumnsensorTyperead-onlycurrentSensor's Type.
1.3.6.1.4.1.55508.1.3.1.1.4ColumnsensorIDread-onlycurrentSensor's ID.
1.3.6.1.4.1.55508.1.3.1.1.5ColumnsensorLocationread-writecurrentSensor's location.
1.3.6.1.4.1.55508.1.3.1.1.6ColumnsensorValueread-onlycurrentSensor's value of smog/door/water.
1.3.6.1.4.1.55508.1.3.1.1.8ColumntemperatureLowLimitread-writecurrentTemperature low limit. NOTE: the UNIT is Deg.C or Deg.F which is select from the setting WEB page.
1.3.6.1.4.1.55508.1.3.1.1.10ColumnhumidityValueread-onlycurrentThe humidity measured by the sensor. A non-negative value indicates the measured humidity in percentage relative humidity. A negative value indicates that a hu…
1.3.6.1.4.1.55508.1.3.1.1.11ColumnhumidityLowLimitread-writecurrentHumidity low limit.
1.3.6.1.4.1.55508.1.3.1.1.12ColumnhumidityHighLimitread-writecurrentHumidity high limit.
1.3.6.1.4.1.55508.1.3.1.1.13ColumnwindValueread-onlycurrentThe wind speed is measured by the sensor. A non-negative value indicates the measured wind speed. A negative value indicates that a wind speed value was not av…
1.3.6.1.4.1.55508.1.3.1.1.14ColumnwindLowLimitread-writecurrentWind speed low limit. see windValue for more detail.
1.3.6.1.4.1.55508.1.3.1.1.15ColumnwindHighLimitread-writecurrentWind speed high limit. see windValue for more detail.
1.3.6.1.4.1.55508.1.3.2TableinternalSensorTablenot-accessiblecurrentA table list the status of internal sensors.
1.3.6.1.4.1.55508.1.3.2.1RowinternalSensorEntrynot-accessiblecurrentRow definition for the status list.
1.3.6.1.4.1.55508.1.3.2.1.1ColumninternalSensorSeqread-onlycurrentSequence of table.
1.3.6.1.4.1.55508.1.3.2.1.2ColumnfanStatusread-onlycurrentFan's status. Normal or Alarm.
1.3.6.1.4.1.55508.1.3.2.1.3ColumntemperatureValueread-onlycurrentInternal temperature Value. The UNIT is Deg.C.
1.3.6.1.4.1.55508.1.3.2.1.4ColumntemperatureHighLimitread-writecurrentInternal temperature high limit. The UNIT is Deg.C.
1.3.6.1.4.1.55508.1.3.2.1.5ColumntemperatureStatusread-onlycurrentTemperature's status. Normal or Alarm.
1.3.6.1.4.1.55508.1.100NodenetPowerTraps
1.3.6.1.4.1.55508.1.100.1NodenetPowerPduAtsEvents
1.3.6.1.4.1.55508.1.100.1.1NotificationfuseEventcurrentFuse event for the PDU outlets. The event would occurred when the fuse is burned/repaired. NMS can check the bound OID 'eventType' for handling the trap.
1.3.6.1.4.1.55508.1.100.1.2NotificationloadEventcurrentLoad event for the PDU outlets and total power. The event would occurred when load is lower/higher than the limit setting or recovery to normal. NMS can check …
1.3.6.1.4.1.55508.1.100.1.3NotificationtemperatureSensorEventcurrentTemperature sensor event. The event would occurred when temperature value is lower/higher than the limit setting or recovery to normal. NMS can check the bound…
1.3.6.1.4.1.55508.1.100.1.4NotificationhumiditySensorEventcurrentHumidity sensor event.The event would occurred when humidity value is lower/higher than the limit setting or recovery to normal. NMS can check the bound OID 'e…
1.3.6.1.4.1.55508.1.100.1.5NotificationwindSensorEventcurrentWind sensor event.The event would occurred when wind speed value is lower/higher than the limit setting or recovery to normal. NMS can check the bound OID 'eve…
1.3.6.1.4.1.55508.1.100.1.6NotificationenvironmentSensorEventcurrentEnvironment sensor event, including smog, water, door and so on. The event would occurred when the sensor detects an alarm or recovery. NMS can check the bound…
1.3.6.1.4.1.55508.1.100.1.7NotificationatsSwitchingEventcurrentATS switch event. The event would occurred when ATS switched the input power A to B, or B to A. NMS can check the bound OID 'eventType' for handling the trap.
1.3.6.1.4.1.55508.1.100.1.8NotificationatsVoltageEventcurrentATS voltage event. The event would occurred when voltage is lower/higher than the limit setting or recovery to normal. NMS can check the bound OID 'eventType' …
1.3.6.1.4.1.55508.1.100.1.9NotificationsnmpQueryTimeoutEventcurrentSnmp Query Timeout event for the PDU snmp connection. The event would occurred when no any query until timeout is come. NMS can check the bound OID 'eventType'…
1.3.6.1.4.1.55508.1.100.1.10NotificationvoltageEventcurrentVoltage event for the PDU input. The event would occurred when voltage is lower/higher than the limit setting or recovery to normal. NMS can check the bound OI…
1.3.6.1.4.1.55508.1.100.1.11NotificationconnectEventcurrentConnect event for the PDU failure. The event would occurred when the power module or outlets module is disconnect/repaired. NMS can check the bound OID 'eventT…