MIB Viewer

SMC-MIB

265 objects
Top-level infrastructure of SMC MIB tree.
Imported Objects
SNMPv2-CONFOBJECT-GROUP
SNMPv2-SMIenterprises Integer32 IpAddress MODULE-IDENTITY OBJECT-TYPE Unsigned32
SNMPv2-TCPhysAddress
OIDNameAccessStatusDescription
1.3.6.1.4.1.10876IdentitysupermicroTop-level infrastructure of SMC MIB tree.
1.3.6.1.4.1.10876.1Nodecmm
1.3.6.1.4.1.10876.1.1Nodenetwork
1.3.6.1.4.1.10876.1.1.1GroupnetGrpBasicSettingscurrentThe group for network basic settings.
1.3.6.1.4.1.10876.1.1.2ScalarnetMACAddrread-onlycurrentCMM MAC address.
1.3.6.1.4.1.10876.1.1.3ScalarnetIPAutoConfread-writecurrentCMM IP auto configuration options. Available options are None, DHCP, BOOTP.
1.3.6.1.4.1.10876.1.1.4ScalarnetHostNameread-writecurrentCMM host name in DHCP mode. User customizable.
1.3.6.1.4.1.10876.1.1.5ScalarnetIPAddrread-writecurrentCMM IPv4 address.
1.3.6.1.4.1.10876.1.1.6ScalarnetNetmaskread-writecurrentCMM IPv4 subnet mask.
1.3.6.1.4.1.10876.1.1.7ScalarnetGatewayread-writecurrentCMM IPv4 gateway IP address.
1.3.6.1.4.1.10876.1.1.8ScalarnetDNS1read-writecurrentCMM primary DNS server IPv4 address.
1.3.6.1.4.1.10876.1.1.9ScalarnetDNS2read-writecurrentCMM secondary DNS server IPv4 address.
1.3.6.1.4.1.10876.1.1.10GroupnetGrpMiscSettingscurrentThe group for network miscellaneous settings.
1.3.6.1.4.1.10876.1.1.11ScalarnetPortHTTPSread-writecurrentPort for Remote Console & HTTPS.
1.3.6.1.4.1.10876.1.1.12ScalarnetPortHTTPread-writecurrentPort for HTTP.
1.3.6.1.4.1.10876.1.1.13ScalarnetPortSSHread-writecurrentPort for SSH.
1.3.6.1.4.1.10876.1.1.14ScalarnetBandWidthLimitread-writecurrentNetwork Bandwidth limit setting. The MAX limitation is 10000 kbit/s
1.3.6.1.4.1.10876.1.1.15ScalarnetSSHAccessread-writecurrentSSH access enable/disable status.
1.3.6.1.4.1.10876.1.1.16ScalarnetSetupProtocolread-writecurrentSetup protocol enable/diable status.
1.3.6.1.4.1.10876.1.1.17GroupnetGrpLANSettingscurrentThe group for LAN interface settings.
1.3.6.1.4.1.10876.1.1.18ScalarnetLANSpeedread-writecurrentLAN interface speed. Available options are AutoDetect, 10Mbps, 100Mbps.
1.3.6.1.4.1.10876.1.1.19ScalarnetLANDuplexModeread-writecurrentLAN interface duplex mode. Available options are AutoDetect, Half Duplex, Full Duplex.
1.3.6.1.4.1.10876.1.1.20GroupnetGrpDDNSSettingscurrentThe group for dynamic DNS settings.
1.3.6.1.4.1.10876.1.1.21ScalarnetDDNSStatusread-writecurrentDDNS enable/disable status.
1.3.6.1.4.1.10876.1.1.22ScalarnetDDNSServerread-onlycurrentDDNS server.
1.3.6.1.4.1.10876.1.1.23ScalarnetDDNSSystemModeread-writecurrentDDNS system mode. Available options are Dynamic, Custom.
1.3.6.1.4.1.10876.1.1.24ScalarnetDDNSHostNameread-writecurrentCMM host name in DDNS mode.
1.3.6.1.4.1.10876.1.1.25ScalarnetDDNSUserNameread-writecurrentCMM user name in DDNS mode.
1.3.6.1.4.1.10876.1.1.26ScalarnetDDNSPasswordread-writecurrentCMM password in DDNS mode.
1.3.6.1.4.1.10876.1.1.27ScalarnetDDNSCheckTimeread-writecurrentDDNS check time.
1.3.6.1.4.1.10876.1.1.28ScalarnetDDNSCheckIntervalread-writecurrentDDNS check interval. Available options are 24h, 12h, 6h, 3h, 2h, 10min, 1min.
1.3.6.1.4.1.10876.1.3Nodeusers
1.3.6.1.4.1.10876.1.3.1TableuserMgmtTablenot-accessiblecurrentThis is the table for CMM user account management.
1.3.6.1.4.1.10876.1.3.1.1RowuserMgmtEntrynot-accessiblecurrentThe table entry for a CMM user.
1.3.6.1.4.1.10876.1.3.1.1.1ColumnuserIndexnot-accessiblecurrentThe index for user management table.
1.3.6.1.4.1.10876.1.3.1.1.2ColumnuserPresenceread-onlycurrentThe indication for user presence.
1.3.6.1.4.1.10876.1.3.1.1.3ColumnuserNameread-writecurrentThe indication for user name.
1.3.6.1.4.1.10876.1.3.1.1.4ColumnuserFullNameread-writecurrentThe indication for user full name.
1.3.6.1.4.1.10876.1.3.1.1.5ColumnuserPasswordread-writecurrentThe indication for user password.
1.3.6.1.4.1.10876.1.3.1.1.6ColumnuserEmailread-writecurrentThe indication for user email address.
1.3.6.1.4.1.10876.1.3.1.1.7ColumnuserMobileread-writecurrentThe indication for user mobile number.
1.3.6.1.4.1.10876.1.3.1.1.8ColumnuserPrivread-writecurrentThe indication for user IPMI privilege.
1.3.6.1.4.1.10876.1.4Nodeblades
1.3.6.1.4.1.10876.1.4.1TablebladeTablenot-accessiblecurrentThe table for blade summary from the CMM management perspective.
1.3.6.1.4.1.10876.1.4.1.1RowbladeEntrynot-accessiblecurrentThe table entry for blade summary information.
1.3.6.1.4.1.10876.1.4.1.1.1ColumnbladeIndexnot-accessiblecurrentThe index for blade table.
1.3.6.1.4.1.10876.1.4.1.1.2ColumnbladeSlotIDread-onlycurrentThe indication for blade slot ID.
1.3.6.1.4.1.10876.1.4.1.1.3ColumnbladePresenceread-onlycurrentThe indication for blade presence.
1.3.6.1.4.1.10876.1.4.1.1.4ColumnbladeNameread-onlycurrentThe indication for blade name.
1.3.6.1.4.1.10876.1.4.1.1.5ColumnbladeModelread-onlycurrentThe indication for blade model.
1.3.6.1.4.1.10876.1.4.1.1.6ColumnbladePowerStatusread-writecurrentThe indication for blade power status and control.
1.3.6.1.4.1.10876.1.4.1.1.7ColumnbladePowerWattread-onlycurrentThe indication for blade current power consumption.
1.3.6.1.4.1.10876.1.4.1.1.8ColumnbladePowerControlread-writecurrentThe indication for blade power control.
1.3.6.1.4.1.10876.1.4.1.1.9ColumnbladeACLostPolicyread-writecurrentThe indication for blade AC power lost policy.
1.3.6.1.4.1.10876.1.4.1.1.10ColumnbladeKVMStatusread-writecurrentThe indication for blade KVM status.
1.3.6.1.4.1.10876.1.4.1.1.11ColumnbladeUIDread-writecurrentThe indication for blade UID status and control.
1.3.6.1.4.1.10876.1.4.1.1.12ColumnbladeErrorread-onlycurrentThe indication for blade error status.
1.3.6.1.4.1.10876.1.4.1.1.13ColumnbladeMgmtIPAddrread-onlycurrentThe indication for blade BMC IPv4 address.
1.3.6.1.4.1.10876.1.4.1.1.14ColumnbladeSNread-onlycurrentThe indication for blade serial number.
1.3.6.1.4.1.10876.1.4.1.1.15ColumnbladeBMCVersionread-onlycurrentThe indication for blade BMC version.
1.3.6.1.4.1.10876.1.4.1.1.16ColumnbladeBIOSVersionread-onlycurrentThe indication for blade BIOS version.
1.3.6.1.4.1.10876.1.5Nodeswitches
1.3.6.1.4.1.10876.1.5.1TableswitchGBTablenot-accessiblecurrentThe table for gigabit switch summary from the CMM management perspective.
1.3.6.1.4.1.10876.1.5.1.1RowswitchGBEntrynot-accessiblecurrentThe table entry for gigabit switch summary information management.
1.3.6.1.4.1.10876.1.5.1.1.1ColumnswitchGBIndexnot-accessiblecurrentThe index for gigabit switch table.
1.3.6.1.4.1.10876.1.5.1.1.2ColumnswitchGBSlotIDread-onlycurrentThe indication of switch slot.
1.3.6.1.4.1.10876.1.5.1.1.3ColumnswitchGBPresenceread-onlycurrentThe indication for switch presence.
1.3.6.1.4.1.10876.1.5.1.1.4ColumnswitchGBNameread-onlycurrentThe indication for switch name.
1.3.6.1.4.1.10876.1.5.1.1.5ColumnswitchGBModelread-onlycurrentThe indication for switch model.
1.3.6.1.4.1.10876.1.5.1.1.6ColumnswitchGBPowerStatusread-writecurrentThe indication for switch power status.
1.3.6.1.4.1.10876.1.5.1.1.7ColumnswitchGBTemperatureread-onlycurrentThe indication for switch temperature.
1.3.6.1.4.1.10876.1.5.1.1.8ColumnswitchGBErrorread-onlycurrentThe indication for switch error status.
1.3.6.1.4.1.10876.1.5.1.1.9ColumnswitchGBInitializedread-onlycurrentThe indication for switch initialization status.
1.3.6.1.4.1.10876.1.5.1.1.10ColumnswitchGB2V5read-onlycurrentThe indication for switch 2.5V voltage.
1.3.6.1.4.1.10876.1.5.1.1.11ColumnswitchGB1V25read-onlycurrentThe indication for switch 1.25V voltage.
1.3.6.1.4.1.10876.1.5.2Tableswitch10GBTablenot-accessiblecurrentThe table for 10 gigabit switch summary from the CMM management perspective.
1.3.6.1.4.1.10876.1.5.2.1Rowswitch10GBEntrynot-accessiblecurrentThe table entry for 10 gigabit switch summary information management.
1.3.6.1.4.1.10876.1.5.2.1.1Columnswitch10GBIndexnot-accessiblecurrentThe index for 10 gigabit switch table.
1.3.6.1.4.1.10876.1.5.2.1.2Columnswitch10GBSlotIDread-onlycurrentThe indication of switch slot.
1.3.6.1.4.1.10876.1.5.2.1.3Columnswitch10GBPresenceread-onlycurrentThe indication for switch presence.
1.3.6.1.4.1.10876.1.5.2.1.4Columnswitch10GBNameread-onlycurrentThe indication for switch name.
1.3.6.1.4.1.10876.1.5.2.1.5Columnswitch10GBModelread-onlycurrentThe indication for switch model.
1.3.6.1.4.1.10876.1.5.2.1.6Columnswitch10GBPowerStatusread-writecurrentThe indication for switch power status.
1.3.6.1.4.1.10876.1.5.2.1.7Columnswitch10GBTemperatureread-onlycurrentThe indication for switch temperature.
1.3.6.1.4.1.10876.1.5.2.1.8Columnswitch10GBErrorread-onlycurrentThe indication for switch error status.
1.3.6.1.4.1.10876.1.5.2.1.9Columnswitch10GBInitializedread-onlycurrentThe indication for switch initialization status.
1.3.6.1.4.1.10876.1.5.2.1.10Columnswitch10GB3V3read-onlycurrentThe indication for switch 3.3V voltage.
1.3.6.1.4.1.10876.1.5.2.1.11Columnswitch10GB1V25read-onlycurrentThe indication for switch 1.25V voltage.
1.3.6.1.4.1.10876.1.5.3Tablepassthru10GBTablenot-accessiblecurrentThe table for 10 gigabit passthrough summary from the CMM management perspective.
1.3.6.1.4.1.10876.1.5.3.1Rowpassthru10GBEntrynot-accessiblecurrentThe table entry for 10 gigabit passthrough summary information management .
1.3.6.1.4.1.10876.1.5.3.1.1Columnpassthru10GBIndexnot-accessiblecurrentThe index for 10 gigabit passthrough table.
1.3.6.1.4.1.10876.1.5.3.1.2Columnpassthru10GBSlotIDread-onlycurrentThe indication of passthrough slot.
1.3.6.1.4.1.10876.1.5.3.1.3Columnpassthru10GBPresenceread-onlycurrentThe indication for passthrough presence.
1.3.6.1.4.1.10876.1.5.3.1.4Columnpassthru10GBNameread-onlycurrentThe indication for passthrough name.
1.3.6.1.4.1.10876.1.5.3.1.5Columnpassthru10GBModelread-onlycurrentThe indication for passthrough model.
1.3.6.1.4.1.10876.1.5.3.1.6Columnpassthru10GBPowerStatusread-writecurrentThe indication for passthrough power status.
1.3.6.1.4.1.10876.1.5.3.1.7Columnpassthru10GBTemperatureread-onlycurrentThe indication for passthrough temperature.
1.3.6.1.4.1.10876.1.5.3.1.8Columnpassthru10GBErrorread-onlycurrentThe indication for passthrough error status.
1.3.6.1.4.1.10876.1.5.3.1.9Columnpassthru10GBInitializedread-onlycurrentThe indication for passthrough initialization status.
1.3.6.1.4.1.10876.1.5.3.1.10Columnpassthru10GB3V3read-onlycurrentThe indication for passthrough 3.3V voltage.
1.3.6.1.4.1.10876.1.5.3.1.11Columnpassthru10GB1V25read-onlycurrentThe indication for passthrough 1.25V voltage.
1.3.6.1.4.1.10876.1.5.4TableswitchIBTablenot-accessiblecurrentThe table for IB switch summary from the CMM management perspective.
1.3.6.1.4.1.10876.1.5.4.1RowswitchIBEntrynot-accessiblecurrentThe table entry for IB switch summary information management.
1.3.6.1.4.1.10876.1.5.4.1.1ColumnswitchIBIndexnot-accessiblecurrentThe index for IB switch table.
1.3.6.1.4.1.10876.1.5.4.1.2ColumnswitchIBSlotIDread-onlycurrentThe indication of switch slot.
1.3.6.1.4.1.10876.1.5.4.1.3ColumnswitchIBPresenceread-onlycurrentThe indication for switch presence.
1.3.6.1.4.1.10876.1.5.4.1.4ColumnswitchIBNameread-onlycurrentThe indication for switch name.
1.3.6.1.4.1.10876.1.5.4.1.5ColumnswitchIBModelread-onlycurrentThe indication for switch model.
1.3.6.1.4.1.10876.1.5.4.1.6ColumnswitchIBPowerStatusread-writecurrentThe indication for switch power status.
1.3.6.1.4.1.10876.1.5.4.1.7ColumnswitchIBTemperatureread-onlycurrentThe indication for switch temperature.
1.3.6.1.4.1.10876.1.5.4.1.8ColumnswitchIBInitializedread-onlycurrentThe indication for switch initialization status.
1.3.6.1.4.1.10876.1.5.4.1.9ColumnswitchIB3V3Auxread-onlycurrentThe indication for switch 3.3V AUX voltage.
1.3.6.1.4.1.10876.1.5.4.1.10ColumnswitchIB3V3read-onlycurrentThe indication for switch 3.3V voltage.
1.3.6.1.4.1.10876.1.5.4.1.11ColumnswitchIB1V8read-onlycurrentThe indication for switch 1.8V voltage.
1.3.6.1.4.1.10876.1.5.4.1.12ColumnswitchIB1V2read-onlycurrentThe indication for switch 1.2V voltage.
1.3.6.1.4.1.10876.1.5.4.1.13ColumnswitchIBVVddread-onlycurrentThe indication for switch VVDD voltage.
1.3.6.1.4.1.10876.1.5.5TableswitchIBQDRTablenot-accessiblecurrentThe table for IB QDR switch summary from the CMM management perspective.
1.3.6.1.4.1.10876.1.5.5.1RowswitchIBQDREntrynot-accessiblecurrentThe table entry for IB QDR switch summary information management.
1.3.6.1.4.1.10876.1.5.5.1.1ColumnswitchIBQDRIndexnot-accessiblecurrentThe index for IB QDR switch table.
1.3.6.1.4.1.10876.1.5.5.1.2ColumnswitchIBQDRSlotIDread-onlycurrentThe indication of switch slot.
1.3.6.1.4.1.10876.1.5.5.1.3ColumnswitchIBQDRPresenceread-onlycurrentThe indication for switch presence.
1.3.6.1.4.1.10876.1.5.5.1.4ColumnswitchIBQDRNameread-onlycurrentThe indication for switch name.
1.3.6.1.4.1.10876.1.5.5.1.5ColumnswitchIBQDRModelread-onlycurrentThe indication for switch model.
1.3.6.1.4.1.10876.1.5.5.1.6ColumnswitchIBQDRPowerStatusread-writecurrentThe indication for switch power status.
1.3.6.1.4.1.10876.1.5.5.1.7ColumnswitchIBQDRTemperatureread-onlycurrentThe indication for switch temperature.
1.3.6.1.4.1.10876.1.5.5.1.8ColumnswitchIBQDRInitializedread-onlycurrentThe indication for switch initialization status.
1.3.6.1.4.1.10876.1.5.5.1.9ColumnswitchIBQDRErrorread-onlycurrentThe indication for switch error status.
1.3.6.1.4.1.10876.1.5.5.1.10ColumnswitchIBQDR3V3read-onlycurrentThe indication for switch 3.3V voltage.
1.3.6.1.4.1.10876.1.5.5.1.11ColumnswitchIBQDR1V25read-onlycurrentThe indication for switch 1.25V voltage.
1.3.6.1.4.1.10876.1.5.6TableswitchIBFDRTablenot-accessiblecurrentThe table for IB FDR switch summary from the CMM management perspective.
1.3.6.1.4.1.10876.1.5.6.1RowswitchIBFDREntrynot-accessiblecurrentThe table entry for IB FDR switch summary information management.
1.3.6.1.4.1.10876.1.5.6.1.1ColumnswitchIBFDRIndexnot-accessiblecurrentThe index for IB FDR switch table.
1.3.6.1.4.1.10876.1.5.6.1.2ColumnswitchIBFDRSlotIDread-onlycurrentThe indication of switch slot.
1.3.6.1.4.1.10876.1.5.6.1.3ColumnswitchIBFDRPresenceread-onlycurrentThe indication for switch presence.
1.3.6.1.4.1.10876.1.5.6.1.4ColumnswitchIBFDRNameread-onlycurrentThe indication for switch name.
1.3.6.1.4.1.10876.1.5.6.1.5ColumnswitchIBFDRModelread-onlycurrentThe indication for switch model.
1.3.6.1.4.1.10876.1.5.6.1.6ColumnswitchIBFDRPowerStatusread-writecurrentThe indication for switch power status.
1.3.6.1.4.1.10876.1.5.6.1.7ColumnswitchIBFDRTemp1read-onlycurrentThe indication for switch temperature 1.
1.3.6.1.4.1.10876.1.5.6.1.8ColumnswitchIBFDRTemp2read-onlycurrentThe indication for switch temperature 2.
1.3.6.1.4.1.10876.1.5.6.1.9ColumnswitchIBFDRInitializedread-onlycurrentThe indication for switch initialization status.
1.3.6.1.4.1.10876.1.5.6.1.10ColumnswitchIBFDRErrorread-onlycurrentThe indication for switch error status.
1.3.6.1.4.1.10876.1.5.6.1.11ColumnswitchIBFDR3V3read-onlycurrentThe indication for switch 3.3V voltage.
1.3.6.1.4.1.10876.1.5.6.1.12ColumnswitchIBFDR1V2read-onlycurrentThe indication for switch 1.2V voltage.
1.3.6.1.4.1.10876.1.5.6.1.13ColumnswitchIBFDR0V9read-onlycurrentThe indication for switch 0.9V voltage.
1.3.6.1.4.1.10876.1.6NodepowerSupplies
1.3.6.1.4.1.10876.1.6.1TablepsuTablenot-accessiblecurrentThe table for power supply management from CMM perspective.
1.3.6.1.4.1.10876.1.6.1.1RowpsuEntrynot-accessiblecurrentThe table entry for power supply management.
1.3.6.1.4.1.10876.1.6.1.1.1ColumnpsuIndexnot-accessiblecurrentThe index for power supply table.
1.3.6.1.4.1.10876.1.6.1.1.2ColumnpsuSlotIDread-onlycurrentThe indication for power supply slot index.
1.3.6.1.4.1.10876.1.6.1.1.3ColumnpsuPresenceread-onlycurrentThe indication for power supply presence.
1.3.6.1.4.1.10876.1.6.1.1.4ColumnpsuNameread-onlycurrentThe indication for power supply name.
1.3.6.1.4.1.10876.1.6.1.1.5ColumnpsuModelread-onlycurrentThe indication for power supply model name.
1.3.6.1.4.1.10876.1.6.1.1.6ColumnpsuPowerStatusread-writecurrentThe indication for power supply power status.
1.3.6.1.4.1.10876.1.6.1.1.7ColumnpsuTemperatureread-onlycurrentThe indication for power supply temperature.
1.3.6.1.4.1.10876.1.6.1.1.8ColumnpsuFAN1Speedread-onlycurrentThe indication for power supply FAN1 speed (RPM).
1.3.6.1.4.1.10876.1.6.1.1.9ColumnpsuFAN2Speedread-onlycurrentThe indication for power supply FAN2 speed (RPM).
1.3.6.1.4.1.10876.1.6.1.1.10ColumnpsuFAN3Speedread-onlycurrentThe indication for power supply FAN3(if exists) speed (RPM).
1.3.6.1.4.1.10876.1.6.1.1.11ColumnpsuFAN4Speedread-onlycurrentThe indication for power supply FAN4(if exists) speed (RPM).
1.3.6.1.4.1.10876.1.6.1.1.12ColumnpsuACInVoltageread-onlycurrentThe indication for power supply AC Input Voltage.
1.3.6.1.4.1.10876.1.6.1.1.13ColumnpsuMaxWattread-onlycurrentThe indication for power supply MAX Watts.
1.3.6.1.4.1.10876.1.6.1.1.14ColumnpsuACInCurrentread-onlycurrentThe indication for power supply AC Input Current.
1.3.6.1.4.1.10876.1.6.1.1.15ColumnpsuDCOutCurrentread-onlycurrentThe indication for power supply DC Out Current.
1.3.6.1.4.1.10876.1.6.1.1.16ColumnpsuCurrentPwrUsageread-onlycurrentThe indication for power supply Current Power Usage.
1.3.6.1.4.1.10876.1.6.1.1.17ColumnpsuFWVersionread-onlycurrentThe indication for power supply F/W version.
1.3.6.1.4.1.10876.1.6.1.1.18ColumnpsuFRUVersionread-onlycurrentThe indication for power supply FRU version.
1.3.6.1.4.1.10876.1.6.2GrouppwrGrpConsumptioncurrentThe group for power consumption.
1.3.6.1.4.1.10876.1.6.3ScalarpwrTotalPowerread-onlycurrentThe indication for total power of all available power supplies.
1.3.6.1.4.1.10876.1.6.4ScalarpwrBladeReservedread-onlycurrentThe indication for blade reserved power.
1.3.6.1.4.1.10876.1.6.5ScalarpwrPeripheralReservedread-onlycurrentThe indication for peripheral reserved power.
1.3.6.1.4.1.10876.1.6.6ScalarpwrAvailablePowerread-onlycurrentThe indication for available power.
1.3.6.1.4.1.10876.1.6.7ScalarpwrCurrentMaxTempread-onlycurrentThe indication for current MAX temperature within all available modules.
1.3.6.1.4.1.10876.1.6.8ScalarpwrCurrentMaxTempModuleread-onlycurrentThe indication for the module with current MAX temperature.
1.3.6.1.4.1.10876.1.6.9GrouppwrGrpPSURedundancycurrentThe group for power supply redundancy.
1.3.6.1.4.1.10876.1.6.10ScalarpwrRedundancyread-writecurrentThe indication for power redundancy policy. Enabled - PSU Redundancy (7+1).
1.3.6.1.4.1.10876.1.6.11GrouppwrGrpPSUFanCtrlcurrentThe group for power supply FAN control.
1.3.6.1.4.1.10876.1.6.12ScalarpwrPSUFanCtrlread-writecurrentThe indication for power supply FAN control policy.
1.3.6.1.4.1.10876.1.6.13ScalarpwrPSUFanSpdCtrlread-writecurrentThe indication for power supply FAN speed control when pwrPSUFanCtrl is in userCtrl mode.
1.3.6.1.4.1.10876.1.7Nodecmms
1.3.6.1.4.1.10876.1.7.1TablecmmTablenot-accessiblecurrentThe table for CMM management.
1.3.6.1.4.1.10876.1.7.1.1RowcmmEntrynot-accessiblecurrentThe table entry for CMM management.
1.3.6.1.4.1.10876.1.7.1.1.1ColumncmmIndexnot-accessiblecurrentThe index for CMM table.
1.3.6.1.4.1.10876.1.7.1.1.2ColumncmmSlotread-onlycurrentThe indication for CMM slot index.
1.3.6.1.4.1.10876.1.7.1.1.3ColumncmmPresenceread-onlycurrentThe indication for CMM presence.
1.3.6.1.4.1.10876.1.7.1.1.4ColumncmmNameread-writecurrentThe indication for CMM name (user defined).
1.3.6.1.4.1.10876.1.7.1.1.5ColumncmmRoleread-onlycurrentThe indication for CMM role (master/slave).
1.3.6.1.4.1.10876.1.7.1.1.6ColumncmmIPAddrread-onlycurrentThe indication for CMM IP address.
1.3.6.1.4.1.10876.1.7.1.1.7ColumncmmStatusread-onlycurrentThe indication for CMM available status.
1.3.6.1.4.1.10876.1.7.1.1.8ColumncmmFWVersionread-onlycurrentThe indication for CMM firmware version.
1.3.6.1.4.1.10876.1.7.1.1.9ColumncmmFWTagread-onlycurrentThe indication for CMM firmware tag.
1.3.6.1.4.1.10876.1.7.2ScalarcmmOperationModeread-writecurrentThe indication for CMM operation mode (enterprise/office).
1.3.6.1.4.1.10876.1.7.3ScalarcmmDateTimeread-writecurrentThe indication for CMM date and time. The format must be MM/dd/yyyy HH:mm:ss.
1.3.6.1.4.1.10876.1.7.4ScalarcmmNTPStatusread-writecurrentThe indication for CMM date and time synchronization mode (user specified /NTP server auto sync).
1.3.6.1.4.1.10876.1.7.5ScalarcmmNTPServer1read-writecurrentThe indication for the primary NTP server for CMM.
1.3.6.1.4.1.10876.1.7.6ScalarcmmNTPServer2read-writecurrentThe indication for the secondary NTP server for CMM.
1.3.6.1.4.1.10876.1.7.7ScalarcmmUTCOffsetread-writecurrentThe indication for CMM UTC offset.
1.3.6.1.4.1.10876.1.8Nodefru
1.3.6.1.4.1.10876.1.8.1TablefruTablenot-accessibleobsoleteThe table for FRU of all devices managed by CMM.
1.3.6.1.4.1.10876.1.8.1.1RowfruEntrynot-accessibleobsoleteThe table entry for FRU of all devices managed by CMM.
1.3.6.1.4.1.10876.1.8.1.1.1ColumnfruTableIndexnot-accessibleobsoleteThe index for the table for FRU of all devices managed by CMM.
1.3.6.1.4.1.10876.1.8.1.1.2ColumnfruDeviceTyperead-onlyobsoleteThe indication for the FRU device type.
1.3.6.1.4.1.10876.1.8.1.1.3ColumnfruDeviceSlotread-onlyobsoleteThe indication for the FRU device slot.
1.3.6.1.4.1.10876.1.8.1.1.4ColumnfruDevIDread-onlyobsoleteThe indication for the FRU block device ID.
1.3.6.1.4.1.10876.1.8.1.1.5ColumnfruChassisTyperead-onlyobsoleteThe indication for the chassis type defined in FRU specification.
1.3.6.1.4.1.10876.1.8.1.1.6ColumnfruChassisTypeCoderead-onlyobsoleteThe indication for the chassis type code.
1.3.6.1.4.1.10876.1.8.1.1.7ColumnfruChassisPNread-onlyobsoleteThe indication for the chassis part number.
1.3.6.1.4.1.10876.1.8.1.1.8ColumnfruChassisSNread-onlyobsoleteThe indication for the chassis serial number.
1.3.6.1.4.1.10876.1.8.1.1.9ColumnfruBoardLangread-onlyobsoleteThe indication for the board language.
1.3.6.1.4.1.10876.1.8.1.1.10ColumnfruBoardLangCoderead-onlyobsoleteThe indication for the board language code.
1.3.6.1.4.1.10876.1.8.1.1.11ColumnfruBoardMfgDatetimeread-onlyobsoleteThe indication for the board manufactory datetime.
1.3.6.1.4.1.10876.1.8.1.1.12ColumnfruBoardMfgNameread-onlyobsoleteThe indication for the board manufactory name.
1.3.6.1.4.1.10876.1.8.1.1.13ColumnfruBoardProdNameread-onlyobsoleteThe indication for the baord product name.
1.3.6.1.4.1.10876.1.8.1.1.14ColumnfruBoardSNread-onlyobsoleteThe indication for the board serial number.
1.3.6.1.4.1.10876.1.8.1.1.15ColumnfruBoardPNread-onlyobsoleteThe indication for the board part number.
1.3.6.1.4.1.10876.1.8.1.1.16ColumnfruProdLangread-onlyobsoleteThe indication for the product language.
1.3.6.1.4.1.10876.1.8.1.1.17ColumnfruProdLangCoderead-onlyobsoleteThe indication for the product language code.
1.3.6.1.4.1.10876.1.8.1.1.18ColumnfruProdMfgNameread-onlyobsoleteThe indication for the product manufactory name.
1.3.6.1.4.1.10876.1.8.1.1.19ColumnfruProdProdNameread-onlyobsoleteThe indication for the product name.
1.3.6.1.4.1.10876.1.8.1.1.20ColumnfruProdPNread-onlyobsoleteThe indication for the product part/model number.
1.3.6.1.4.1.10876.1.8.1.1.21ColumnfruProdVersionread-onlyobsoleteThe indication for the product version.
1.3.6.1.4.1.10876.1.8.1.1.22ColumnfruProdSNread-onlyobsoleteThe indication for the product serial number.
1.3.6.1.4.1.10876.1.8.1.1.23ColumnfruProdAssetTagread-onlyobsoleteThe indication for the product asset tag.
1.3.6.1.4.1.10876.1.9NodevirtualMedias
1.3.6.1.4.1.10876.1.9.1ScalarfloppyActiveImage1read-onlyobsoleteFloppy Drive 1 active image information.
1.3.6.1.4.1.10876.1.9.2ScalarfloppyActiveImage2read-onlyobsoleteFloppy Drive 2 active image information.
1.3.6.1.4.1.10876.1.9.3ScalarcdromActiveImage1read-onlyobsoleteCDROM Drive 1 active image information.
1.3.6.1.4.1.10876.1.9.4ScalarcdromActiveImage2read-onlyobsoleteCDROM Drive 2 active image information.
1.3.6.1.4.1.10876.1.9.5ScalardrvRedirActiveImage1read-onlyobsoleteDrive Redirection Drive 1 active image information.
1.3.6.1.4.1.10876.1.9.6ScalardrvRedirActiveImage2read-onlyobsoleteDrive Redirection Drive 2 active image information.
1.3.6.1.4.1.10876.1.9.7ScalardrvRedirStatusread-writecurrentDrive Redirection enable/disable status.
1.3.6.1.4.1.10876.1.9.8ScalardrvRedirAccessTyperead-writecurrentDrive Redirection connections access options (readonly/readwrite).
1.3.6.1.4.1.10876.1.9.9ScalarusbEnableWithoutImageread-writecurrentOptions to enable/disable USB Mass Storage if no image is loaded.
1.3.6.1.4.1.10876.1.10NodekvmSettings
1.3.6.1.4.1.10876.1.10.1ScalarkeyboardModelread-writecurrentKeyboard Model options.
1.3.6.1.4.1.10876.1.10.2ScalarkeyReleaseTimeoutStatusread-writecurrentKey release timeout enable/disable.
1.3.6.1.4.1.10876.1.10.3ScalarkeyReleaseTimeoutIntervalread-writecurrentKey release timeout interval. Available options are 25, 50, 100, 200 msec.
1.3.6.1.4.1.10876.1.10.4ScalarmouseTyperead-writecurrentUSB mouse type options. Option absolute for Windows (2000 or above) and Mac OS X. Option relative for the other OS.
1.3.6.1.4.1.10876.1.10.5ScalarmouseSpeedread-writecurrentMouse speed, only available when mouseType is set to otherOS. Available options are Auto, or Fixed Scaling (1:0.25, 1:0.50, 1:1.00, 1:2. 00, 1:4.00).
1.3.6.1.4.1.10876.1.11NodeeventLogging
1.3.6.1.4.1.10876.1.11.1GroupevtGrpLogTargetSettingscurrentThe group for event log target settings.
1.3.6.1.4.1.10876.1.11.2ScalarevtListLogStatusread-writecurrentShow the event log list enable/diable status.
1.3.6.1.4.1.10876.1.11.3ScalarevtListEntryPerPageread-writecurrentEntries number per page. Default is 20.
1.3.6.1.4.1.10876.1.11.4ScalarevtListClearLogread-writecurrentA write only action for clear CMM internal log.
1.3.6.1.4.1.10876.1.11.5ScalarevtNFSLogStatusread-writecurrentEvent log for NFS logging enable/diable status.
1.3.6.1.4.1.10876.1.11.6ScalarevtNFSServerread-writecurrentThe NFS server for logging.
1.3.6.1.4.1.10876.1.11.7ScalarevtNFSShareread-writecurrentThe NFS share for logging.
1.3.6.1.4.1.10876.1.11.8ScalarevtNFSLogFileread-writecurrentThe NFS log file for logging.
1.3.6.1.4.1.10876.1.11.9ScalarevtSMTPLogStatusread-writecurrentEvent log for SMTP logging enable/diable status.
1.3.6.1.4.1.10876.1.11.10ScalarevtSMTPServerread-writecurrentThe SMTP server for logging.
1.3.6.1.4.1.10876.1.11.11ScalarevtSMTPRecvEmailread-writecurrentThe receiver email address for SMTP logging.
1.3.6.1.4.1.10876.1.11.12ScalarevtSMTPSendEmailread-writecurrentThe sender email address for SMTP logging.
1.3.6.1.4.1.10876.1.11.13ScalarevtSNMPLogStatusread-writecurrentEvent log for SNMP logging enable/diable status.
1.3.6.1.4.1.10876.1.11.14ScalarevtSNMPDestIPread-writecurrentThe destination IP address for SNMP logging.
1.3.6.1.4.1.10876.1.11.15ScalarevtSNMPCommunityread-writecurrentThe community name for SNMP logging.
1.3.6.1.5Nodesecurity
1.3.6.1.5.1GroupsecGrpEncryptionSettingscurrentThe group for encryption settings.
1.3.6.1.5.2ScalarsecForceWebHTTPSread-writecurrentForce HTTPS for web access.
1.3.6.1.5.3ScalarsecKVMEncryptionread-writecurrentKVM encryption setting. Available options are Off, Try, Force.
1.3.6.1.5.4GroupsecGrpIPAccessControlcurrentThe group for IP access control settings.
1.3.6.1.5.5ScalarsecIPFWStatusread-writecurrentIP Access Control enable/disable status.
1.3.6.1.5.6ScalarsecIPFWDefaultPolicyread-writecurrentDefault policy for IP access control.
1.3.6.1.5.7GroupsecGrpLoginFailBlockingcurrentThe group for login failure blocking settings.
1.3.6.1.5.8ScalarsecLoginRetryCountread-writecurrentMax number of failed login attempts [0..1024]. -1 for Infinite.
1.3.6.1.5.9ScalarsecLoginBlockTimeread-writecurrentBlock time for the login failure retry limit reached [0..10080]min. -1 for infinite.
1.3.6.1.5.10GroupsecIPMISettingscurrentThe group for IPMI security control settings
1.3.6.1.5.11ScalarsecSMCRAKPread-writecurrentSMC RAKP feature enable/disable. It's disabled by default. IPMI LAN channel will be disabled while this inidication is enabled.