SMC-MIB
265 objects
Top-level infrastructure of SMC MIB tree.
Imported Objects
| SNMPv2-CONF | OBJECT-GROUP |
| SNMPv2-SMI | enterprises Integer32 IpAddress MODULE-IDENTITY OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | PhysAddress |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.10876 | Identitysupermicro | Top-level infrastructure of SMC MIB tree. | ||
| 1.3.6.1.4.1.10876.1 | Nodecmm | |||
| 1.3.6.1.4.1.10876.1.1 | Nodenetwork | |||
| 1.3.6.1.4.1.10876.1.1.1 | GroupnetGrpBasicSettings | current | The group for network basic settings. | |
| 1.3.6.1.4.1.10876.1.1.2 | ScalarnetMACAddr | read-only | current | CMM MAC address. |
| 1.3.6.1.4.1.10876.1.1.3 | ScalarnetIPAutoConf | read-write | current | CMM IP auto configuration options. Available options are None, DHCP, BOOTP. |
| 1.3.6.1.4.1.10876.1.1.4 | ScalarnetHostName | read-write | current | CMM host name in DHCP mode. User customizable. |
| 1.3.6.1.4.1.10876.1.1.5 | ScalarnetIPAddr | read-write | current | CMM IPv4 address. |
| 1.3.6.1.4.1.10876.1.1.6 | ScalarnetNetmask | read-write | current | CMM IPv4 subnet mask. |
| 1.3.6.1.4.1.10876.1.1.7 | ScalarnetGateway | read-write | current | CMM IPv4 gateway IP address. |
| 1.3.6.1.4.1.10876.1.1.8 | ScalarnetDNS1 | read-write | current | CMM primary DNS server IPv4 address. |
| 1.3.6.1.4.1.10876.1.1.9 | ScalarnetDNS2 | read-write | current | CMM secondary DNS server IPv4 address. |
| 1.3.6.1.4.1.10876.1.1.10 | GroupnetGrpMiscSettings | current | The group for network miscellaneous settings. | |
| 1.3.6.1.4.1.10876.1.1.11 | ScalarnetPortHTTPS | read-write | current | Port for Remote Console & HTTPS. |
| 1.3.6.1.4.1.10876.1.1.12 | ScalarnetPortHTTP | read-write | current | Port for HTTP. |
| 1.3.6.1.4.1.10876.1.1.13 | ScalarnetPortSSH | read-write | current | Port for SSH. |
| 1.3.6.1.4.1.10876.1.1.14 | ScalarnetBandWidthLimit | read-write | current | Network Bandwidth limit setting. The MAX limitation is 10000 kbit/s |
| 1.3.6.1.4.1.10876.1.1.15 | ScalarnetSSHAccess | read-write | current | SSH access enable/disable status. |
| 1.3.6.1.4.1.10876.1.1.16 | ScalarnetSetupProtocol | read-write | current | Setup protocol enable/diable status. |
| 1.3.6.1.4.1.10876.1.1.17 | GroupnetGrpLANSettings | current | The group for LAN interface settings. | |
| 1.3.6.1.4.1.10876.1.1.18 | ScalarnetLANSpeed | read-write | current | LAN interface speed. Available options are AutoDetect, 10Mbps, 100Mbps. |
| 1.3.6.1.4.1.10876.1.1.19 | ScalarnetLANDuplexMode | read-write | current | LAN interface duplex mode. Available options are AutoDetect, Half Duplex, Full Duplex. |
| 1.3.6.1.4.1.10876.1.1.20 | GroupnetGrpDDNSSettings | current | The group for dynamic DNS settings. | |
| 1.3.6.1.4.1.10876.1.1.21 | ScalarnetDDNSStatus | read-write | current | DDNS enable/disable status. |
| 1.3.6.1.4.1.10876.1.1.22 | ScalarnetDDNSServer | read-only | current | DDNS server. |
| 1.3.6.1.4.1.10876.1.1.23 | ScalarnetDDNSSystemMode | read-write | current | DDNS system mode. Available options are Dynamic, Custom. |
| 1.3.6.1.4.1.10876.1.1.24 | ScalarnetDDNSHostName | read-write | current | CMM host name in DDNS mode. |
| 1.3.6.1.4.1.10876.1.1.25 | ScalarnetDDNSUserName | read-write | current | CMM user name in DDNS mode. |
| 1.3.6.1.4.1.10876.1.1.26 | ScalarnetDDNSPassword | read-write | current | CMM password in DDNS mode. |
| 1.3.6.1.4.1.10876.1.1.27 | ScalarnetDDNSCheckTime | read-write | current | DDNS check time. |
| 1.3.6.1.4.1.10876.1.1.28 | ScalarnetDDNSCheckInterval | read-write | current | DDNS check interval. Available options are 24h, 12h, 6h, 3h, 2h, 10min, 1min. |
| 1.3.6.1.4.1.10876.1.3 | Nodeusers | |||
| 1.3.6.1.4.1.10876.1.3.1 | TableuserMgmtTable | not-accessible | current | This is the table for CMM user account management. |
| 1.3.6.1.4.1.10876.1.3.1.1 | RowuserMgmtEntry | not-accessible | current | The table entry for a CMM user. |
| 1.3.6.1.4.1.10876.1.3.1.1.1 | ColumnuserIndex | not-accessible | current | The index for user management table. |
| 1.3.6.1.4.1.10876.1.3.1.1.2 | ColumnuserPresence | read-only | current | The indication for user presence. |
| 1.3.6.1.4.1.10876.1.3.1.1.3 | ColumnuserName | read-write | current | The indication for user name. |
| 1.3.6.1.4.1.10876.1.3.1.1.4 | ColumnuserFullName | read-write | current | The indication for user full name. |
| 1.3.6.1.4.1.10876.1.3.1.1.5 | ColumnuserPassword | read-write | current | The indication for user password. |
| 1.3.6.1.4.1.10876.1.3.1.1.6 | ColumnuserEmail | read-write | current | The indication for user email address. |
| 1.3.6.1.4.1.10876.1.3.1.1.7 | ColumnuserMobile | read-write | current | The indication for user mobile number. |
| 1.3.6.1.4.1.10876.1.3.1.1.8 | ColumnuserPriv | read-write | current | The indication for user IPMI privilege. |
| 1.3.6.1.4.1.10876.1.4 | Nodeblades | |||
| 1.3.6.1.4.1.10876.1.4.1 | TablebladeTable | not-accessible | current | The table for blade summary from the CMM management perspective. |
| 1.3.6.1.4.1.10876.1.4.1.1 | RowbladeEntry | not-accessible | current | The table entry for blade summary information. |
| 1.3.6.1.4.1.10876.1.4.1.1.1 | ColumnbladeIndex | not-accessible | current | The index for blade table. |
| 1.3.6.1.4.1.10876.1.4.1.1.2 | ColumnbladeSlotID | read-only | current | The indication for blade slot ID. |
| 1.3.6.1.4.1.10876.1.4.1.1.3 | ColumnbladePresence | read-only | current | The indication for blade presence. |
| 1.3.6.1.4.1.10876.1.4.1.1.4 | ColumnbladeName | read-only | current | The indication for blade name. |
| 1.3.6.1.4.1.10876.1.4.1.1.5 | ColumnbladeModel | read-only | current | The indication for blade model. |
| 1.3.6.1.4.1.10876.1.4.1.1.6 | ColumnbladePowerStatus | read-write | current | The indication for blade power status and control. |
| 1.3.6.1.4.1.10876.1.4.1.1.7 | ColumnbladePowerWatt | read-only | current | The indication for blade current power consumption. |
| 1.3.6.1.4.1.10876.1.4.1.1.8 | ColumnbladePowerControl | read-write | current | The indication for blade power control. |
| 1.3.6.1.4.1.10876.1.4.1.1.9 | ColumnbladeACLostPolicy | read-write | current | The indication for blade AC power lost policy. |
| 1.3.6.1.4.1.10876.1.4.1.1.10 | ColumnbladeKVMStatus | read-write | current | The indication for blade KVM status. |
| 1.3.6.1.4.1.10876.1.4.1.1.11 | ColumnbladeUID | read-write | current | The indication for blade UID status and control. |
| 1.3.6.1.4.1.10876.1.4.1.1.12 | ColumnbladeError | read-only | current | The indication for blade error status. |
| 1.3.6.1.4.1.10876.1.4.1.1.13 | ColumnbladeMgmtIPAddr | read-only | current | The indication for blade BMC IPv4 address. |
| 1.3.6.1.4.1.10876.1.4.1.1.14 | ColumnbladeSN | read-only | current | The indication for blade serial number. |
| 1.3.6.1.4.1.10876.1.4.1.1.15 | ColumnbladeBMCVersion | read-only | current | The indication for blade BMC version. |
| 1.3.6.1.4.1.10876.1.4.1.1.16 | ColumnbladeBIOSVersion | read-only | current | The indication for blade BIOS version. |
| 1.3.6.1.4.1.10876.1.5 | Nodeswitches | |||
| 1.3.6.1.4.1.10876.1.5.1 | TableswitchGBTable | not-accessible | current | The table for gigabit switch summary from the CMM management perspective. |
| 1.3.6.1.4.1.10876.1.5.1.1 | RowswitchGBEntry | not-accessible | current | The table entry for gigabit switch summary information management. |
| 1.3.6.1.4.1.10876.1.5.1.1.1 | ColumnswitchGBIndex | not-accessible | current | The index for gigabit switch table. |
| 1.3.6.1.4.1.10876.1.5.1.1.2 | ColumnswitchGBSlotID | read-only | current | The indication of switch slot. |
| 1.3.6.1.4.1.10876.1.5.1.1.3 | ColumnswitchGBPresence | read-only | current | The indication for switch presence. |
| 1.3.6.1.4.1.10876.1.5.1.1.4 | ColumnswitchGBName | read-only | current | The indication for switch name. |
| 1.3.6.1.4.1.10876.1.5.1.1.5 | ColumnswitchGBModel | read-only | current | The indication for switch model. |
| 1.3.6.1.4.1.10876.1.5.1.1.6 | ColumnswitchGBPowerStatus | read-write | current | The indication for switch power status. |
| 1.3.6.1.4.1.10876.1.5.1.1.7 | ColumnswitchGBTemperature | read-only | current | The indication for switch temperature. |
| 1.3.6.1.4.1.10876.1.5.1.1.8 | ColumnswitchGBError | read-only | current | The indication for switch error status. |
| 1.3.6.1.4.1.10876.1.5.1.1.9 | ColumnswitchGBInitialized | read-only | current | The indication for switch initialization status. |
| 1.3.6.1.4.1.10876.1.5.1.1.10 | ColumnswitchGB2V5 | read-only | current | The indication for switch 2.5V voltage. |
| 1.3.6.1.4.1.10876.1.5.1.1.11 | ColumnswitchGB1V25 | read-only | current | The indication for switch 1.25V voltage. |
| 1.3.6.1.4.1.10876.1.5.2 | Tableswitch10GBTable | not-accessible | current | The table for 10 gigabit switch summary from the CMM management perspective. |
| 1.3.6.1.4.1.10876.1.5.2.1 | Rowswitch10GBEntry | not-accessible | current | The table entry for 10 gigabit switch summary information management. |
| 1.3.6.1.4.1.10876.1.5.2.1.1 | Columnswitch10GBIndex | not-accessible | current | The index for 10 gigabit switch table. |
| 1.3.6.1.4.1.10876.1.5.2.1.2 | Columnswitch10GBSlotID | read-only | current | The indication of switch slot. |
| 1.3.6.1.4.1.10876.1.5.2.1.3 | Columnswitch10GBPresence | read-only | current | The indication for switch presence. |
| 1.3.6.1.4.1.10876.1.5.2.1.4 | Columnswitch10GBName | read-only | current | The indication for switch name. |
| 1.3.6.1.4.1.10876.1.5.2.1.5 | Columnswitch10GBModel | read-only | current | The indication for switch model. |
| 1.3.6.1.4.1.10876.1.5.2.1.6 | Columnswitch10GBPowerStatus | read-write | current | The indication for switch power status. |
| 1.3.6.1.4.1.10876.1.5.2.1.7 | Columnswitch10GBTemperature | read-only | current | The indication for switch temperature. |
| 1.3.6.1.4.1.10876.1.5.2.1.8 | Columnswitch10GBError | read-only | current | The indication for switch error status. |
| 1.3.6.1.4.1.10876.1.5.2.1.9 | Columnswitch10GBInitialized | read-only | current | The indication for switch initialization status. |
| 1.3.6.1.4.1.10876.1.5.2.1.10 | Columnswitch10GB3V3 | read-only | current | The indication for switch 3.3V voltage. |
| 1.3.6.1.4.1.10876.1.5.2.1.11 | Columnswitch10GB1V25 | read-only | current | The indication for switch 1.25V voltage. |
| 1.3.6.1.4.1.10876.1.5.3 | Tablepassthru10GBTable | not-accessible | current | The table for 10 gigabit passthrough summary from the CMM management perspective. |
| 1.3.6.1.4.1.10876.1.5.3.1 | Rowpassthru10GBEntry | not-accessible | current | The table entry for 10 gigabit passthrough summary information management . |
| 1.3.6.1.4.1.10876.1.5.3.1.1 | Columnpassthru10GBIndex | not-accessible | current | The index for 10 gigabit passthrough table. |
| 1.3.6.1.4.1.10876.1.5.3.1.2 | Columnpassthru10GBSlotID | read-only | current | The indication of passthrough slot. |
| 1.3.6.1.4.1.10876.1.5.3.1.3 | Columnpassthru10GBPresence | read-only | current | The indication for passthrough presence. |
| 1.3.6.1.4.1.10876.1.5.3.1.4 | Columnpassthru10GBName | read-only | current | The indication for passthrough name. |
| 1.3.6.1.4.1.10876.1.5.3.1.5 | Columnpassthru10GBModel | read-only | current | The indication for passthrough model. |
| 1.3.6.1.4.1.10876.1.5.3.1.6 | Columnpassthru10GBPowerStatus | read-write | current | The indication for passthrough power status. |
| 1.3.6.1.4.1.10876.1.5.3.1.7 | Columnpassthru10GBTemperature | read-only | current | The indication for passthrough temperature. |
| 1.3.6.1.4.1.10876.1.5.3.1.8 | Columnpassthru10GBError | read-only | current | The indication for passthrough error status. |
| 1.3.6.1.4.1.10876.1.5.3.1.9 | Columnpassthru10GBInitialized | read-only | current | The indication for passthrough initialization status. |
| 1.3.6.1.4.1.10876.1.5.3.1.10 | Columnpassthru10GB3V3 | read-only | current | The indication for passthrough 3.3V voltage. |
| 1.3.6.1.4.1.10876.1.5.3.1.11 | Columnpassthru10GB1V25 | read-only | current | The indication for passthrough 1.25V voltage. |
| 1.3.6.1.4.1.10876.1.5.4 | TableswitchIBTable | not-accessible | current | The table for IB switch summary from the CMM management perspective. |
| 1.3.6.1.4.1.10876.1.5.4.1 | RowswitchIBEntry | not-accessible | current | The table entry for IB switch summary information management. |
| 1.3.6.1.4.1.10876.1.5.4.1.1 | ColumnswitchIBIndex | not-accessible | current | The index for IB switch table. |
| 1.3.6.1.4.1.10876.1.5.4.1.2 | ColumnswitchIBSlotID | read-only | current | The indication of switch slot. |
| 1.3.6.1.4.1.10876.1.5.4.1.3 | ColumnswitchIBPresence | read-only | current | The indication for switch presence. |
| 1.3.6.1.4.1.10876.1.5.4.1.4 | ColumnswitchIBName | read-only | current | The indication for switch name. |
| 1.3.6.1.4.1.10876.1.5.4.1.5 | ColumnswitchIBModel | read-only | current | The indication for switch model. |
| 1.3.6.1.4.1.10876.1.5.4.1.6 | ColumnswitchIBPowerStatus | read-write | current | The indication for switch power status. |
| 1.3.6.1.4.1.10876.1.5.4.1.7 | ColumnswitchIBTemperature | read-only | current | The indication for switch temperature. |
| 1.3.6.1.4.1.10876.1.5.4.1.8 | ColumnswitchIBInitialized | read-only | current | The indication for switch initialization status. |
| 1.3.6.1.4.1.10876.1.5.4.1.9 | ColumnswitchIB3V3Aux | read-only | current | The indication for switch 3.3V AUX voltage. |
| 1.3.6.1.4.1.10876.1.5.4.1.10 | ColumnswitchIB3V3 | read-only | current | The indication for switch 3.3V voltage. |
| 1.3.6.1.4.1.10876.1.5.4.1.11 | ColumnswitchIB1V8 | read-only | current | The indication for switch 1.8V voltage. |
| 1.3.6.1.4.1.10876.1.5.4.1.12 | ColumnswitchIB1V2 | read-only | current | The indication for switch 1.2V voltage. |
| 1.3.6.1.4.1.10876.1.5.4.1.13 | ColumnswitchIBVVdd | read-only | current | The indication for switch VVDD voltage. |
| 1.3.6.1.4.1.10876.1.5.5 | TableswitchIBQDRTable | not-accessible | current | The table for IB QDR switch summary from the CMM management perspective. |
| 1.3.6.1.4.1.10876.1.5.5.1 | RowswitchIBQDREntry | not-accessible | current | The table entry for IB QDR switch summary information management. |
| 1.3.6.1.4.1.10876.1.5.5.1.1 | ColumnswitchIBQDRIndex | not-accessible | current | The index for IB QDR switch table. |
| 1.3.6.1.4.1.10876.1.5.5.1.2 | ColumnswitchIBQDRSlotID | read-only | current | The indication of switch slot. |
| 1.3.6.1.4.1.10876.1.5.5.1.3 | ColumnswitchIBQDRPresence | read-only | current | The indication for switch presence. |
| 1.3.6.1.4.1.10876.1.5.5.1.4 | ColumnswitchIBQDRName | read-only | current | The indication for switch name. |
| 1.3.6.1.4.1.10876.1.5.5.1.5 | ColumnswitchIBQDRModel | read-only | current | The indication for switch model. |
| 1.3.6.1.4.1.10876.1.5.5.1.6 | ColumnswitchIBQDRPowerStatus | read-write | current | The indication for switch power status. |
| 1.3.6.1.4.1.10876.1.5.5.1.7 | ColumnswitchIBQDRTemperature | read-only | current | The indication for switch temperature. |
| 1.3.6.1.4.1.10876.1.5.5.1.8 | ColumnswitchIBQDRInitialized | read-only | current | The indication for switch initialization status. |
| 1.3.6.1.4.1.10876.1.5.5.1.9 | ColumnswitchIBQDRError | read-only | current | The indication for switch error status. |
| 1.3.6.1.4.1.10876.1.5.5.1.10 | ColumnswitchIBQDR3V3 | read-only | current | The indication for switch 3.3V voltage. |
| 1.3.6.1.4.1.10876.1.5.5.1.11 | ColumnswitchIBQDR1V25 | read-only | current | The indication for switch 1.25V voltage. |
| 1.3.6.1.4.1.10876.1.5.6 | TableswitchIBFDRTable | not-accessible | current | The table for IB FDR switch summary from the CMM management perspective. |
| 1.3.6.1.4.1.10876.1.5.6.1 | RowswitchIBFDREntry | not-accessible | current | The table entry for IB FDR switch summary information management. |
| 1.3.6.1.4.1.10876.1.5.6.1.1 | ColumnswitchIBFDRIndex | not-accessible | current | The index for IB FDR switch table. |
| 1.3.6.1.4.1.10876.1.5.6.1.2 | ColumnswitchIBFDRSlotID | read-only | current | The indication of switch slot. |
| 1.3.6.1.4.1.10876.1.5.6.1.3 | ColumnswitchIBFDRPresence | read-only | current | The indication for switch presence. |
| 1.3.6.1.4.1.10876.1.5.6.1.4 | ColumnswitchIBFDRName | read-only | current | The indication for switch name. |
| 1.3.6.1.4.1.10876.1.5.6.1.5 | ColumnswitchIBFDRModel | read-only | current | The indication for switch model. |
| 1.3.6.1.4.1.10876.1.5.6.1.6 | ColumnswitchIBFDRPowerStatus | read-write | current | The indication for switch power status. |
| 1.3.6.1.4.1.10876.1.5.6.1.7 | ColumnswitchIBFDRTemp1 | read-only | current | The indication for switch temperature 1. |
| 1.3.6.1.4.1.10876.1.5.6.1.8 | ColumnswitchIBFDRTemp2 | read-only | current | The indication for switch temperature 2. |
| 1.3.6.1.4.1.10876.1.5.6.1.9 | ColumnswitchIBFDRInitialized | read-only | current | The indication for switch initialization status. |
| 1.3.6.1.4.1.10876.1.5.6.1.10 | ColumnswitchIBFDRError | read-only | current | The indication for switch error status. |
| 1.3.6.1.4.1.10876.1.5.6.1.11 | ColumnswitchIBFDR3V3 | read-only | current | The indication for switch 3.3V voltage. |
| 1.3.6.1.4.1.10876.1.5.6.1.12 | ColumnswitchIBFDR1V2 | read-only | current | The indication for switch 1.2V voltage. |
| 1.3.6.1.4.1.10876.1.5.6.1.13 | ColumnswitchIBFDR0V9 | read-only | current | The indication for switch 0.9V voltage. |
| 1.3.6.1.4.1.10876.1.6 | NodepowerSupplies | |||
| 1.3.6.1.4.1.10876.1.6.1 | TablepsuTable | not-accessible | current | The table for power supply management from CMM perspective. |
| 1.3.6.1.4.1.10876.1.6.1.1 | RowpsuEntry | not-accessible | current | The table entry for power supply management. |
| 1.3.6.1.4.1.10876.1.6.1.1.1 | ColumnpsuIndex | not-accessible | current | The index for power supply table. |
| 1.3.6.1.4.1.10876.1.6.1.1.2 | ColumnpsuSlotID | read-only | current | The indication for power supply slot index. |
| 1.3.6.1.4.1.10876.1.6.1.1.3 | ColumnpsuPresence | read-only | current | The indication for power supply presence. |
| 1.3.6.1.4.1.10876.1.6.1.1.4 | ColumnpsuName | read-only | current | The indication for power supply name. |
| 1.3.6.1.4.1.10876.1.6.1.1.5 | ColumnpsuModel | read-only | current | The indication for power supply model name. |
| 1.3.6.1.4.1.10876.1.6.1.1.6 | ColumnpsuPowerStatus | read-write | current | The indication for power supply power status. |
| 1.3.6.1.4.1.10876.1.6.1.1.7 | ColumnpsuTemperature | read-only | current | The indication for power supply temperature. |
| 1.3.6.1.4.1.10876.1.6.1.1.8 | ColumnpsuFAN1Speed | read-only | current | The indication for power supply FAN1 speed (RPM). |
| 1.3.6.1.4.1.10876.1.6.1.1.9 | ColumnpsuFAN2Speed | read-only | current | The indication for power supply FAN2 speed (RPM). |
| 1.3.6.1.4.1.10876.1.6.1.1.10 | ColumnpsuFAN3Speed | read-only | current | The indication for power supply FAN3(if exists) speed (RPM). |
| 1.3.6.1.4.1.10876.1.6.1.1.11 | ColumnpsuFAN4Speed | read-only | current | The indication for power supply FAN4(if exists) speed (RPM). |
| 1.3.6.1.4.1.10876.1.6.1.1.12 | ColumnpsuACInVoltage | read-only | current | The indication for power supply AC Input Voltage. |
| 1.3.6.1.4.1.10876.1.6.1.1.13 | ColumnpsuMaxWatt | read-only | current | The indication for power supply MAX Watts. |
| 1.3.6.1.4.1.10876.1.6.1.1.14 | ColumnpsuACInCurrent | read-only | current | The indication for power supply AC Input Current. |
| 1.3.6.1.4.1.10876.1.6.1.1.15 | ColumnpsuDCOutCurrent | read-only | current | The indication for power supply DC Out Current. |
| 1.3.6.1.4.1.10876.1.6.1.1.16 | ColumnpsuCurrentPwrUsage | read-only | current | The indication for power supply Current Power Usage. |
| 1.3.6.1.4.1.10876.1.6.1.1.17 | ColumnpsuFWVersion | read-only | current | The indication for power supply F/W version. |
| 1.3.6.1.4.1.10876.1.6.1.1.18 | ColumnpsuFRUVersion | read-only | current | The indication for power supply FRU version. |
| 1.3.6.1.4.1.10876.1.6.2 | GrouppwrGrpConsumption | current | The group for power consumption. | |
| 1.3.6.1.4.1.10876.1.6.3 | ScalarpwrTotalPower | read-only | current | The indication for total power of all available power supplies. |
| 1.3.6.1.4.1.10876.1.6.4 | ScalarpwrBladeReserved | read-only | current | The indication for blade reserved power. |
| 1.3.6.1.4.1.10876.1.6.5 | ScalarpwrPeripheralReserved | read-only | current | The indication for peripheral reserved power. |
| 1.3.6.1.4.1.10876.1.6.6 | ScalarpwrAvailablePower | read-only | current | The indication for available power. |
| 1.3.6.1.4.1.10876.1.6.7 | ScalarpwrCurrentMaxTemp | read-only | current | The indication for current MAX temperature within all available modules. |
| 1.3.6.1.4.1.10876.1.6.8 | ScalarpwrCurrentMaxTempModule | read-only | current | The indication for the module with current MAX temperature. |
| 1.3.6.1.4.1.10876.1.6.9 | GrouppwrGrpPSURedundancy | current | The group for power supply redundancy. | |
| 1.3.6.1.4.1.10876.1.6.10 | ScalarpwrRedundancy | read-write | current | The indication for power redundancy policy. Enabled - PSU Redundancy (7+1). |
| 1.3.6.1.4.1.10876.1.6.11 | GrouppwrGrpPSUFanCtrl | current | The group for power supply FAN control. | |
| 1.3.6.1.4.1.10876.1.6.12 | ScalarpwrPSUFanCtrl | read-write | current | The indication for power supply FAN control policy. |
| 1.3.6.1.4.1.10876.1.6.13 | ScalarpwrPSUFanSpdCtrl | read-write | current | The indication for power supply FAN speed control when pwrPSUFanCtrl is in userCtrl mode. |
| 1.3.6.1.4.1.10876.1.7 | Nodecmms | |||
| 1.3.6.1.4.1.10876.1.7.1 | TablecmmTable | not-accessible | current | The table for CMM management. |
| 1.3.6.1.4.1.10876.1.7.1.1 | RowcmmEntry | not-accessible | current | The table entry for CMM management. |
| 1.3.6.1.4.1.10876.1.7.1.1.1 | ColumncmmIndex | not-accessible | current | The index for CMM table. |
| 1.3.6.1.4.1.10876.1.7.1.1.2 | ColumncmmSlot | read-only | current | The indication for CMM slot index. |
| 1.3.6.1.4.1.10876.1.7.1.1.3 | ColumncmmPresence | read-only | current | The indication for CMM presence. |
| 1.3.6.1.4.1.10876.1.7.1.1.4 | ColumncmmName | read-write | current | The indication for CMM name (user defined). |
| 1.3.6.1.4.1.10876.1.7.1.1.5 | ColumncmmRole | read-only | current | The indication for CMM role (master/slave). |
| 1.3.6.1.4.1.10876.1.7.1.1.6 | ColumncmmIPAddr | read-only | current | The indication for CMM IP address. |
| 1.3.6.1.4.1.10876.1.7.1.1.7 | ColumncmmStatus | read-only | current | The indication for CMM available status. |
| 1.3.6.1.4.1.10876.1.7.1.1.8 | ColumncmmFWVersion | read-only | current | The indication for CMM firmware version. |
| 1.3.6.1.4.1.10876.1.7.1.1.9 | ColumncmmFWTag | read-only | current | The indication for CMM firmware tag. |
| 1.3.6.1.4.1.10876.1.7.2 | ScalarcmmOperationMode | read-write | current | The indication for CMM operation mode (enterprise/office). |
| 1.3.6.1.4.1.10876.1.7.3 | ScalarcmmDateTime | read-write | current | The indication for CMM date and time. The format must be MM/dd/yyyy HH:mm:ss. |
| 1.3.6.1.4.1.10876.1.7.4 | ScalarcmmNTPStatus | read-write | current | The indication for CMM date and time synchronization mode (user specified /NTP server auto sync). |
| 1.3.6.1.4.1.10876.1.7.5 | ScalarcmmNTPServer1 | read-write | current | The indication for the primary NTP server for CMM. |
| 1.3.6.1.4.1.10876.1.7.6 | ScalarcmmNTPServer2 | read-write | current | The indication for the secondary NTP server for CMM. |
| 1.3.6.1.4.1.10876.1.7.7 | ScalarcmmUTCOffset | read-write | current | The indication for CMM UTC offset. |
| 1.3.6.1.4.1.10876.1.8 | Nodefru | |||
| 1.3.6.1.4.1.10876.1.8.1 | TablefruTable | not-accessible | obsolete | The table for FRU of all devices managed by CMM. |
| 1.3.6.1.4.1.10876.1.8.1.1 | RowfruEntry | not-accessible | obsolete | The table entry for FRU of all devices managed by CMM. |
| 1.3.6.1.4.1.10876.1.8.1.1.1 | ColumnfruTableIndex | not-accessible | obsolete | The index for the table for FRU of all devices managed by CMM. |
| 1.3.6.1.4.1.10876.1.8.1.1.2 | ColumnfruDeviceType | read-only | obsolete | The indication for the FRU device type. |
| 1.3.6.1.4.1.10876.1.8.1.1.3 | ColumnfruDeviceSlot | read-only | obsolete | The indication for the FRU device slot. |
| 1.3.6.1.4.1.10876.1.8.1.1.4 | ColumnfruDevID | read-only | obsolete | The indication for the FRU block device ID. |
| 1.3.6.1.4.1.10876.1.8.1.1.5 | ColumnfruChassisType | read-only | obsolete | The indication for the chassis type defined in FRU specification. |
| 1.3.6.1.4.1.10876.1.8.1.1.6 | ColumnfruChassisTypeCode | read-only | obsolete | The indication for the chassis type code. |
| 1.3.6.1.4.1.10876.1.8.1.1.7 | ColumnfruChassisPN | read-only | obsolete | The indication for the chassis part number. |
| 1.3.6.1.4.1.10876.1.8.1.1.8 | ColumnfruChassisSN | read-only | obsolete | The indication for the chassis serial number. |
| 1.3.6.1.4.1.10876.1.8.1.1.9 | ColumnfruBoardLang | read-only | obsolete | The indication for the board language. |
| 1.3.6.1.4.1.10876.1.8.1.1.10 | ColumnfruBoardLangCode | read-only | obsolete | The indication for the board language code. |
| 1.3.6.1.4.1.10876.1.8.1.1.11 | ColumnfruBoardMfgDatetime | read-only | obsolete | The indication for the board manufactory datetime. |
| 1.3.6.1.4.1.10876.1.8.1.1.12 | ColumnfruBoardMfgName | read-only | obsolete | The indication for the board manufactory name. |
| 1.3.6.1.4.1.10876.1.8.1.1.13 | ColumnfruBoardProdName | read-only | obsolete | The indication for the baord product name. |
| 1.3.6.1.4.1.10876.1.8.1.1.14 | ColumnfruBoardSN | read-only | obsolete | The indication for the board serial number. |
| 1.3.6.1.4.1.10876.1.8.1.1.15 | ColumnfruBoardPN | read-only | obsolete | The indication for the board part number. |
| 1.3.6.1.4.1.10876.1.8.1.1.16 | ColumnfruProdLang | read-only | obsolete | The indication for the product language. |
| 1.3.6.1.4.1.10876.1.8.1.1.17 | ColumnfruProdLangCode | read-only | obsolete | The indication for the product language code. |
| 1.3.6.1.4.1.10876.1.8.1.1.18 | ColumnfruProdMfgName | read-only | obsolete | The indication for the product manufactory name. |
| 1.3.6.1.4.1.10876.1.8.1.1.19 | ColumnfruProdProdName | read-only | obsolete | The indication for the product name. |
| 1.3.6.1.4.1.10876.1.8.1.1.20 | ColumnfruProdPN | read-only | obsolete | The indication for the product part/model number. |
| 1.3.6.1.4.1.10876.1.8.1.1.21 | ColumnfruProdVersion | read-only | obsolete | The indication for the product version. |
| 1.3.6.1.4.1.10876.1.8.1.1.22 | ColumnfruProdSN | read-only | obsolete | The indication for the product serial number. |
| 1.3.6.1.4.1.10876.1.8.1.1.23 | ColumnfruProdAssetTag | read-only | obsolete | The indication for the product asset tag. |
| 1.3.6.1.4.1.10876.1.9 | NodevirtualMedias | |||
| 1.3.6.1.4.1.10876.1.9.1 | ScalarfloppyActiveImage1 | read-only | obsolete | Floppy Drive 1 active image information. |
| 1.3.6.1.4.1.10876.1.9.2 | ScalarfloppyActiveImage2 | read-only | obsolete | Floppy Drive 2 active image information. |
| 1.3.6.1.4.1.10876.1.9.3 | ScalarcdromActiveImage1 | read-only | obsolete | CDROM Drive 1 active image information. |
| 1.3.6.1.4.1.10876.1.9.4 | ScalarcdromActiveImage2 | read-only | obsolete | CDROM Drive 2 active image information. |
| 1.3.6.1.4.1.10876.1.9.5 | ScalardrvRedirActiveImage1 | read-only | obsolete | Drive Redirection Drive 1 active image information. |
| 1.3.6.1.4.1.10876.1.9.6 | ScalardrvRedirActiveImage2 | read-only | obsolete | Drive Redirection Drive 2 active image information. |
| 1.3.6.1.4.1.10876.1.9.7 | ScalardrvRedirStatus | read-write | current | Drive Redirection enable/disable status. |
| 1.3.6.1.4.1.10876.1.9.8 | ScalardrvRedirAccessType | read-write | current | Drive Redirection connections access options (readonly/readwrite). |
| 1.3.6.1.4.1.10876.1.9.9 | ScalarusbEnableWithoutImage | read-write | current | Options to enable/disable USB Mass Storage if no image is loaded. |
| 1.3.6.1.4.1.10876.1.10 | NodekvmSettings | |||
| 1.3.6.1.4.1.10876.1.10.1 | ScalarkeyboardModel | read-write | current | Keyboard Model options. |
| 1.3.6.1.4.1.10876.1.10.2 | ScalarkeyReleaseTimeoutStatus | read-write | current | Key release timeout enable/disable. |
| 1.3.6.1.4.1.10876.1.10.3 | ScalarkeyReleaseTimeoutInterval | read-write | current | Key release timeout interval. Available options are 25, 50, 100, 200 msec. |
| 1.3.6.1.4.1.10876.1.10.4 | ScalarmouseType | read-write | current | USB mouse type options. Option absolute for Windows (2000 or above) and Mac OS X. Option relative for the other OS. |
| 1.3.6.1.4.1.10876.1.10.5 | ScalarmouseSpeed | read-write | current | Mouse speed, only available when mouseType is set to otherOS. Available options are Auto, or Fixed Scaling (1:0.25, 1:0.50, 1:1.00, 1:2. 00, 1:4.00). |
| 1.3.6.1.4.1.10876.1.11 | NodeeventLogging | |||
| 1.3.6.1.4.1.10876.1.11.1 | GroupevtGrpLogTargetSettings | current | The group for event log target settings. | |
| 1.3.6.1.4.1.10876.1.11.2 | ScalarevtListLogStatus | read-write | current | Show the event log list enable/diable status. |
| 1.3.6.1.4.1.10876.1.11.3 | ScalarevtListEntryPerPage | read-write | current | Entries number per page. Default is 20. |
| 1.3.6.1.4.1.10876.1.11.4 | ScalarevtListClearLog | read-write | current | A write only action for clear CMM internal log. |
| 1.3.6.1.4.1.10876.1.11.5 | ScalarevtNFSLogStatus | read-write | current | Event log for NFS logging enable/diable status. |
| 1.3.6.1.4.1.10876.1.11.6 | ScalarevtNFSServer | read-write | current | The NFS server for logging. |
| 1.3.6.1.4.1.10876.1.11.7 | ScalarevtNFSShare | read-write | current | The NFS share for logging. |
| 1.3.6.1.4.1.10876.1.11.8 | ScalarevtNFSLogFile | read-write | current | The NFS log file for logging. |
| 1.3.6.1.4.1.10876.1.11.9 | ScalarevtSMTPLogStatus | read-write | current | Event log for SMTP logging enable/diable status. |
| 1.3.6.1.4.1.10876.1.11.10 | ScalarevtSMTPServer | read-write | current | The SMTP server for logging. |
| 1.3.6.1.4.1.10876.1.11.11 | ScalarevtSMTPRecvEmail | read-write | current | The receiver email address for SMTP logging. |
| 1.3.6.1.4.1.10876.1.11.12 | ScalarevtSMTPSendEmail | read-write | current | The sender email address for SMTP logging. |
| 1.3.6.1.4.1.10876.1.11.13 | ScalarevtSNMPLogStatus | read-write | current | Event log for SNMP logging enable/diable status. |
| 1.3.6.1.4.1.10876.1.11.14 | ScalarevtSNMPDestIP | read-write | current | The destination IP address for SNMP logging. |
| 1.3.6.1.4.1.10876.1.11.15 | ScalarevtSNMPCommunity | read-write | current | The community name for SNMP logging. |
| 1.3.6.1.5 | Nodesecurity | |||
| 1.3.6.1.5.1 | GroupsecGrpEncryptionSettings | current | The group for encryption settings. | |
| 1.3.6.1.5.2 | ScalarsecForceWebHTTPS | read-write | current | Force HTTPS for web access. |
| 1.3.6.1.5.3 | ScalarsecKVMEncryption | read-write | current | KVM encryption setting. Available options are Off, Try, Force. |
| 1.3.6.1.5.4 | GroupsecGrpIPAccessControl | current | The group for IP access control settings. | |
| 1.3.6.1.5.5 | ScalarsecIPFWStatus | read-write | current | IP Access Control enable/disable status. |
| 1.3.6.1.5.6 | ScalarsecIPFWDefaultPolicy | read-write | current | Default policy for IP access control. |
| 1.3.6.1.5.7 | GroupsecGrpLoginFailBlocking | current | The group for login failure blocking settings. | |
| 1.3.6.1.5.8 | ScalarsecLoginRetryCount | read-write | current | Max number of failed login attempts [0..1024]. -1 for Infinite. |
| 1.3.6.1.5.9 | ScalarsecLoginBlockTime | read-write | current | Block time for the login failure retry limit reached [0..10080]min. -1 for infinite. |
| 1.3.6.1.5.10 | GroupsecIPMISettings | current | The group for IPMI security control settings | |
| 1.3.6.1.5.11 | ScalarsecSMCRAKP | read-write | current | SMC RAKP feature enable/disable. It's disabled by default. IPMI LAN channel will be disabled while this inidication is enabled. |