SNMPSERVER-MIB
1525 objects
No module-level DESCRIPTION found.
Imported Objects
| SNMPv2-SMI | Counter32 Counter64 dod mib-2 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE TimeTicks Unsigned32 |
| SNMPv2-TC | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1 | Nodeinternet | |||
| 1.3.6.1.2 | Nodemgmt | |||
| 1.3.6.1.2.1 | Nodemib-2 | |||
| 1.3.6.1.2.1.1 | Nodesystem | |||
| 1.3.6.1.2.1.1.1 | ScalarsysDescr | read-only | current | |
| 1.3.6.1.2.1.1.2 | ScalarsysObjectID | read-only | current | |
| 1.3.6.1.2.1.1.3 | ScalarsysUpTime | read-only | current | |
| 1.3.6.1.2.1.1.4 | ScalarsysContact | read-write | current | |
| 1.3.6.1.2.1.1.5 | ScalarsysName | read-write | current | |
| 1.3.6.1.2.1.1.6 | ScalarsysLocation | read-write | current | |
| 1.3.6.1.4 | Nodeprivate | |||
| 1.3.6.1.4.1 | Nodeenterprises | |||
| 1.3.6.1.4.1.53332 | Nodetecnairlv | |||
| 1.3.6.1.4.1.53332.1 | Nodenode1 | |||
| 1.3.6.1.4.1.53332.1.0 | Nodetraps1 | |||
| 1.3.6.1.4.1.53332.1.0.1 | NotificationgeneralAlTrap_1 | current | General alarams | |
| 1.3.6.1.4.1.53332.1.0.2 | NotificationnotCriticalAlTrap_1 | current | Not critical alarms | |
| 1.3.6.1.4.1.53332.1.0.3 | NotificationcriticalAlTrap_1 | current | Critical alarms | |
| 1.3.6.1.4.1.53332.1.0.4 | NotificationfansAlTrap_1 | current | Fans alarms | |
| 1.3.6.1.4.1.53332.1.0.5 | NotificationcompAlTrap_1 | current | Compressors alarms | |
| 1.3.6.1.4.1.53332.1.0.6 | NotificationtemperatureAlTrap_1 | current | Temperature alarms | |
| 1.3.6.1.4.1.53332.1.0.7 | NotificationhumidityAlTrap_1 | current | Humidity alarms | |
| 1.3.6.1.4.1.53332.1.0.8 | NotificationdamperAlTrap_1 | current | Damper status alarm | |
| 1.3.6.1.4.1.53332.1.0.9 | NotificationfireSmokeAlTrap_1 | current | Fire/Smoke alarm | |
| 1.3.6.1.4.1.53332.1.0.10 | NotificationgenSeriousAlTrap_1 | current | Critical generic alarm | |
| 1.3.6.1.4.1.53332.1.0.11 | NotificationfansGenAlTrap_1 | current | General supply fans alarm | |
| 1.3.6.1.4.1.53332.1.0.12 | Notificationf1GeneralAlTrap_1 | current | Fan general alarm 1 | |
| 1.3.6.1.4.1.53332.1.0.13 | Notificationf1PowerAlTrap_1 | current | Phase failure/undervolt.1 | |
| 1.3.6.1.4.1.53332.1.0.14 | Notificationf1CommAlTrap_1 | current | Communication 1 | |
| 1.3.6.1.4.1.53332.1.0.15 | Notificationf1HighTempAlTrap_1 | current | Power mod overheated 1 | |
| 1.3.6.1.4.1.53332.1.0.16 | Notificationf1NetComAlTrap_1 | current | Master/Slave com. 1 | |
| 1.3.6.1.4.1.53332.1.0.17 | Notificationf1InvRegAlTrap_1 | current | Regulation module 1 | |
| 1.3.6.1.4.1.53332.1.0.18 | Notificationf1HighMotTempAlTrap_1 | current | Motor overheated 1 | |
| 1.3.6.1.4.1.53332.1.0.19 | Notificationf1HallSensAlTrap_1 | current | Hall sensor error 1 | |
| 1.3.6.1.4.1.53332.1.0.20 | Notificationf1OverloadAlTrap_1 | current | Locked motor 1 | |
| 1.3.6.1.4.1.53332.1.0.21 | Notificationf1LowDCAlTrap_1 | current | Low DC 1 | |
| 1.3.6.1.4.1.53332.1.0.22 | Notificationf2GeneralAlTrap_1 | current | Fan general alarm 2 | |
| 1.3.6.1.4.1.53332.1.0.23 | Notificationf2PowerAlTrap_1 | current | Phase failure/undervolt.2 | |
| 1.3.6.1.4.1.53332.1.0.24 | Notificationf2CommAlTrap_1 | current | Communication 2 | |
| 1.3.6.1.4.1.53332.1.0.25 | Notificationf2HighTempAlTrap_1 | current | Power mod overheated 2 | |
| 1.3.6.1.4.1.53332.1.0.26 | Notificationf2NetComAlTrap_1 | current | Master/Slave com. 2 | |
| 1.3.6.1.4.1.53332.1.0.27 | Notificationf2InvRegAlTrap_1 | current | Regulation module 2 | |
| 1.3.6.1.4.1.53332.1.0.28 | Notificationf2HighMotTempAlTrap_1 | current | Motor overheated 2 | |
| 1.3.6.1.4.1.53332.1.0.29 | Notificationf2HallSensAlTrap_1 | current | Hall sensor error 2 | |
| 1.3.6.1.4.1.53332.1.0.30 | Notificationf2OverloadAlTrap_1 | current | Locked motor 2 | |
| 1.3.6.1.4.1.53332.1.0.31 | Notificationf2LowDCAlTrap_1 | current | Low DC 2 | |
| 1.3.6.1.4.1.53332.1.0.32 | Notificationf3GeneralAlTrap_1 | current | Fan general alarm 3 | |
| 1.3.6.1.4.1.53332.1.0.33 | Notificationf3PowerAlTrap_1 | current | Phase failure/undervolt.3 | |
| 1.3.6.1.4.1.53332.1.0.34 | Notificationf3CommAlTrap_1 | current | Communication 3 | |
| 1.3.6.1.4.1.53332.1.0.35 | Notificationf3HighTempAlTrap_1 | current | Power mod overheated 3 | |
| 1.3.6.1.4.1.53332.1.0.36 | Notificationf3NetComAlTrap_1 | current | Master/Slave com. 3 | |
| 1.3.6.1.4.1.53332.1.0.37 | Notificationf3InvRegAlTrap_1 | current | Regulation module 3 | |
| 1.3.6.1.4.1.53332.1.0.38 | Notificationf3HighMotTempAlTrap_1 | current | Motor overheated 3 | |
| 1.3.6.1.4.1.53332.1.0.39 | Notificationf3HallSensAlTrap_1 | current | Hall sensor error 3 | |
| 1.3.6.1.4.1.53332.1.0.40 | Notificationf3OverloadAlTrap_1 | current | Locked motor 3 | |
| 1.3.6.1.4.1.53332.1.0.41 | Notificationf3LowDCAlTrap_1 | current | Low DC 3 | |
| 1.3.6.1.4.1.53332.1.0.42 | Notificationf4GeneralAlTrap_1 | current | Fan general alarm 4 | |
| 1.3.6.1.4.1.53332.1.0.43 | Notificationf4PowerAlTrap_1 | current | Phase failure/undervolt.4 | |
| 1.3.6.1.4.1.53332.1.0.44 | Notificationf4CommAlTrap_1 | current | Communication 4 | |
| 1.3.6.1.4.1.53332.1.0.45 | Notificationf4HighTempAlTrap_1 | current | Power mod overheated 4 | |
| 1.3.6.1.4.1.53332.1.0.46 | Notificationf4NetComAlTrap_1 | current | Master/Slave com. 4 | |
| 1.3.6.1.4.1.53332.1.0.47 | Notificationf4InvRegAlTrap_1 | current | Regulation module 4 | |
| 1.3.6.1.4.1.53332.1.0.48 | Notificationf4HighMotTempAlTrap_1 | current | Motor overheated 4 | |
| 1.3.6.1.4.1.53332.1.0.49 | Notificationf4HallSensAlTrap_1 | current | Hall sensor error 4 | |
| 1.3.6.1.4.1.53332.1.0.50 | Notificationf4OverloadAlTrap_1 | current | Locked motor 4 | |
| 1.3.6.1.4.1.53332.1.0.51 | Notificationf4LowDCAlTrap_1 | current | Low DC 4 | |
| 1.3.6.1.4.1.53332.1.0.52 | Notificationf5GeneralAlTrap_1 | current | Fan general alarm 5 | |
| 1.3.6.1.4.1.53332.1.0.53 | Notificationf5PowerAlTrap_1 | current | Phase failure/undervolt.5 | |
| 1.3.6.1.4.1.53332.1.0.54 | Notificationf5CommAlTrap_1 | current | Communication 5 | |
| 1.3.6.1.4.1.53332.1.0.55 | Notificationf5HighTempAlTrap_1 | current | Power mod overheated 5 | |
| 1.3.6.1.4.1.53332.1.0.56 | Notificationf5NetComAlTrap_1 | current | Master/Slave com. 5 | |
| 1.3.6.1.4.1.53332.1.0.57 | Notificationf5InvRegAlTrap_1 | current | Regulation module 5 | |
| 1.3.6.1.4.1.53332.1.0.58 | Notificationf5HighMotTempAlTrap_1 | current | Motor overheated 5 | |
| 1.3.6.1.4.1.53332.1.0.59 | Notificationf5HallSensAlTrap_1 | current | Hall sensor error 5 | |
| 1.3.6.1.4.1.53332.1.0.60 | Notificationf5OverloadAlTrap_1 | current | Locked motor 5 | |
| 1.3.6.1.4.1.53332.1.0.61 | Notificationf5LowDCAlTrap_1 | current | Low DC 5 | |
| 1.3.6.1.4.1.53332.1.0.62 | Notificationf6GeneralAlTrap_1 | current | Fan general alarm 6 | |
| 1.3.6.1.4.1.53332.1.0.63 | Notificationf6PowerAlTrap_1 | current | Phase failure/undervolt.6 | |
| 1.3.6.1.4.1.53332.1.0.64 | Notificationf6CommAlTrap_1 | current | Communication 6 | |
| 1.3.6.1.4.1.53332.1.0.65 | Notificationf6HighTempAlTrap_1 | current | Power mod overheated 6 | |
| 1.3.6.1.4.1.53332.1.0.66 | Notificationf6NetComAlTrap_1 | current | Master/Slave com. 6 | |
| 1.3.6.1.4.1.53332.1.0.67 | Notificationf6InvRegAlTrap_1 | current | Regulation module 6 | |
| 1.3.6.1.4.1.53332.1.0.68 | Notificationf6HighMotTempAlTrap_1 | current | Motor overheated 6 | |
| 1.3.6.1.4.1.53332.1.0.69 | Notificationf6HallSensAlTrap_1 | current | Hall sensor error 6 | |
| 1.3.6.1.4.1.53332.1.0.70 | Notificationf6OverloadAlTrap_1 | current | Locked motor 6 | |
| 1.3.6.1.4.1.53332.1.0.71 | Notificationf6LowDCAlTrap_1 | current | Low DC 6 | |
| 1.3.6.1.4.1.53332.1.0.72 | Notificationf7GeneralAlTrap_1 | current | Fan general alarm 7 | |
| 1.3.6.1.4.1.53332.1.0.73 | Notificationf7PowerAlTrap_1 | current | Phase failure/undervolt.7 | |
| 1.3.6.1.4.1.53332.1.0.74 | Notificationf7CommAlTrap_1 | current | Communication 7 | |
| 1.3.6.1.4.1.53332.1.0.75 | Notificationf7HighTempAlTrap_1 | current | Power mod overheated 7 | |
| 1.3.6.1.4.1.53332.1.0.76 | Notificationf7NetComAlTrap_1 | current | Master/Slave com. 7 | |
| 1.3.6.1.4.1.53332.1.0.77 | Notificationf7InvRegAlTrap_1 | current | Regulation module 7 | |
| 1.3.6.1.4.1.53332.1.0.78 | Notificationf7HighMotTempAlTrap_1 | current | Motor overheated 7 | |
| 1.3.6.1.4.1.53332.1.0.79 | Notificationf7HallSensAlTrap_1 | current | Hall sensor error 7 | |
| 1.3.6.1.4.1.53332.1.0.80 | Notificationf7OverloadAlTrap_1 | current | Locked motor 7 | |
| 1.3.6.1.4.1.53332.1.0.81 | Notificationf7LowDCAlTrap_1 | current | Low DC 7 | |
| 1.3.6.1.4.1.53332.1.0.82 | Notificationf8GeneralAlTrap_1 | current | Fan general alarm 8 | |
| 1.3.6.1.4.1.53332.1.0.83 | Notificationf8PowerAlTrap_1 | current | Phase failure/undervolt.8 | |
| 1.3.6.1.4.1.53332.1.0.84 | Notificationf8CommAlTrap_1 | current | Communication 8 | |
| 1.3.6.1.4.1.53332.1.0.85 | Notificationf8HighTempAlTrap_1 | current | Power mod overheated 8 | |
| 1.3.6.1.4.1.53332.1.0.86 | Notificationf8NetComAlTrap_1 | current | Master/Slave com. 8 | |
| 1.3.6.1.4.1.53332.1.0.87 | Notificationf8InvRegAlTrap_1 | current | Regulation module 8 | |
| 1.3.6.1.4.1.53332.1.0.88 | Notificationf8HighMotTempAlTrap_1 | current | Motor overheated 8 | |
| 1.3.6.1.4.1.53332.1.0.89 | Notificationf8HallSensAlTrap_1 | current | Hall sensor error 8 | |
| 1.3.6.1.4.1.53332.1.0.90 | Notificationf8OverloadAlTrap_1 | current | Locked motor 8 | |
| 1.3.6.1.4.1.53332.1.0.91 | Notificationf8LowDCAlTrap_1 | current | Low DC 8 | |
| 1.3.6.1.4.1.53332.1.0.92 | Notificationf9InverterAlTrap_1 | current | Fan general alarm 9 | |
| 1.3.6.1.4.1.53332.1.0.93 | Notificationf9PowerAlTrap_1 | current | Phase failure/undervolt.9 | |
| 1.3.6.1.4.1.53332.1.0.94 | Notificationf9CommAlTrap_1 | current | Communication 9 | |
| 1.3.6.1.4.1.53332.1.0.95 | Notificationf9HighTempAlTrap_1 | current | Power mod overheated 9 | |
| 1.3.6.1.4.1.53332.1.0.96 | Notificationf9NetComAlTrap_1 | current | Master/Slave com. 9 | |
| 1.3.6.1.4.1.53332.1.0.97 | Notificationf9InvRegAlTrap_1 | current | Regulation module 9 | |
| 1.3.6.1.4.1.53332.1.0.98 | Notificationf9HighMotTempAlTrap_1 | current | Motor overheated 9 | |
| 1.3.6.1.4.1.53332.1.0.99 | Notificationf9HallSensAlTrap_1 | current | Hall sensor error 9 | |
| 1.3.6.1.4.1.53332.1.0.100 | Notificationf9OverloadAlTrap_1 | current | Locked motor 9 | |
| 1.3.6.1.4.1.53332.1.0.101 | Notificationf9LowDCAlTrap_1 | current | Low DC 9 | |
| 1.3.6.1.4.1.53332.1.0.102 | Notificationf10GeneralAlTrap_1 | current | Fan general alarm 10 | |
| 1.3.6.1.4.1.53332.1.0.103 | Notificationf10PowerAlTrap_1 | current | Phase failure/undervolt.10 | |
| 1.3.6.1.4.1.53332.1.0.104 | Notificationf10CommAlTrap_1 | current | Communication 10 | |
| 1.3.6.1.4.1.53332.1.0.105 | Notificationf10HighTempAlTrap_1 | current | Power mod overheated 10 | |
| 1.3.6.1.4.1.53332.1.0.106 | Notificationf10NetComAlTrap_1 | current | Master/Slave com. 10 | |
| 1.3.6.1.4.1.53332.1.0.107 | Notificationf10InvRegAlTrap_1 | current | Regulation module 10 | |
| 1.3.6.1.4.1.53332.1.0.108 | Notificationf10HighMotTAlTrap_1 | current | Motor overheated 10 | |
| 1.3.6.1.4.1.53332.1.0.109 | Notificationf10HallSensAlTrap_1 | current | Hall sensor error 10 | |
| 1.3.6.1.4.1.53332.1.0.110 | Notificationf10OverloadAlTrap_1 | current | Locked motor 10 | |
| 1.3.6.1.4.1.53332.1.0.111 | Notificationf10LowDCAlTrap_1 | current | Low DC 10 | |
| 1.3.6.1.4.1.53332.1.0.112 | NotificationretTempProbAlTrap_1 | current | Return temperature probe | |
| 1.3.6.1.4.1.53332.1.0.113 | NotificationsupTempProbAlTrap_1 | current | Supply temperature probe | |
| 1.3.6.1.4.1.53332.1.0.114 | NotificationretHumProbAlTrap_1 | current | Return humidity probe | |
| 1.3.6.1.4.1.53332.1.0.115 | NotificationsupHumProbAlTrap_1 | current | Supply humidity probe | |
| 1.3.6.1.4.1.53332.1.0.116 | NotificationairPrSensorAlTrap_1 | current | Air diff.pressure probe | |
| 1.3.6.1.4.1.53332.1.0.117 | NotificationwatIN1ProbAlTrap_1 | current | Water temp. IN1 probe | |
| 1.3.6.1.4.1.53332.1.0.118 | NotificationwatOUT1ProbAlTrap_1 | current | Water temp. OUT1 probe | |
| 1.3.6.1.4.1.53332.1.0.119 | NotificationwatIN2ProbAlTrap_1 | current | Water temp. IN2 probe | |
| 1.3.6.1.4.1.53332.1.0.120 | NotificationwatOUT2ProbAlTrap_1 | current | Water temp. OUT2 probe | |
| 1.3.6.1.4.1.53332.1.0.121 | NotificationwatFlw1ProbAlTrap_1 | current | Water flow1/T.liquid1 pr. | |
| 1.3.6.1.4.1.53332.1.0.122 | NotificationwatFlw2ProbAlTrap_1 | current | Water flow2/T.liquid2 pr. | |
| 1.3.6.1.4.1.53332.1.0.123 | NotificationdFPSGenAlTrap_1 | current | Filter diff.press. probe | |
| 1.3.6.1.4.1.53332.1.0.124 | NotificationdFPSBrokenAlTrap_1 | current | Breakdown alarm | |
| 1.3.6.1.4.1.53332.1.0.125 | NotificationdFPSCablingAlTrap_1 | current | Wiring alarm | |
| 1.3.6.1.4.1.53332.1.0.126 | NotificationdFPSRangeAlTrap_1 | current | Pressure range alarm | |
| 1.3.6.1.4.1.53332.1.0.127 | NotificationdFPSADCAlTrap_1 | current | ADC overload alarm | |
| 1.3.6.1.4.1.53332.1.0.128 | NotificationdFPSSettingAlTrap_1 | current | Calibration alarm | |
| 1.3.6.1.4.1.53332.1.0.129 | NotificationdFPSDCOAlTrap_1 | current | DCO alarm | |
| 1.3.6.1.4.1.53332.1.0.130 | NotificationdFPSWatchdogAlTrap_1 | current | Watchdog alarm | |
| 1.3.6.1.4.1.53332.1.0.131 | NotificationdFPSCommAlTrap_1 | current | Communication alarm | |
| 1.3.6.1.4.1.53332.1.0.132 | NotificationinvCompGenAlTrap_1 | current | DC inverter general alarm | |
| 1.3.6.1.4.1.53332.1.0.133 | NotificationinvCompCommAlTrap_1 | current | Inverter communication | |
| 1.3.6.1.4.1.53332.1.0.134 | NotificationinvCompAlCode1Trap_1 | current | DC Inverter alarm code 1 | |
| 1.3.6.1.4.1.53332.1.0.135 | NotificationinvCompAlCode2Trap_1 | current | DC Inverter alarm code 2 | |
| 1.3.6.1.4.1.53332.1.0.136 | NotificationinvCompAlCode3Trap_1 | current | DC Inverter alarm code 3 | |
| 1.3.6.1.4.1.53332.1.0.137 | NotificationinvCompAlCode4Trap_1 | current | DC Inverter alarm code 4 | |
| 1.3.6.1.4.1.53332.1.0.138 | NotificationinvCompAlCode5Trap_1 | current | DC Inverter alarm code 5 | |
| 1.3.6.1.4.1.53332.1.0.139 | Notificationc1ThermAlTrap_1 | current | C1 Thermal alarm | |
| 1.3.6.1.4.1.53332.1.0.140 | Notificationc1HighPresAlTrap_1 | current | C1 High pressure alarm | |
| 1.3.6.1.4.1.53332.1.0.141 | Notificationc1LowPresAlTrap_1 | current | C1 Low pressure alarm | |
| 1.3.6.1.4.1.53332.1.0.142 | Notificationc1HighDischAlTrap_1 | current | C1 High discharge alarm | |
| 1.3.6.1.4.1.53332.1.0.143 | Notificationc1LCompRatAlTrap_1 | current | C1 low compresion alarm | |
| 1.3.6.1.4.1.53332.1.0.144 | Notificationcondenser1AlTrap_1 | current | Condenser 1 general alarm | |
| 1.3.6.1.4.1.53332.1.0.145 | Notificationc1WatFlowAlTrap_1 | current | Condenser 1 flow alarm | |
| 1.3.6.1.4.1.53332.1.0.146 | NotificationeEV1GenAlTrap_1 | current | EEV1 general alarm | |
| 1.3.6.1.4.1.53332.1.0.147 | NotificationeEV1CommAlTrap_1 | current | EEV1 communication alarm | |
| 1.3.6.1.4.1.53332.1.0.148 | NotificationeEV1SuctProbAlTrap_1 | current | EEV1 suction temp. probe | |
| 1.3.6.1.4.1.53332.1.0.149 | NotificationeEV1EvapProbAlTrap_1 | current | EEV1 evap. temp. probe | |
| 1.3.6.1.4.1.53332.1.0.150 | NotificationeEV1CondProbAlTrap_1 | current | EEV1 condens. temp. probe | |
| 1.3.6.1.4.1.53332.1.0.151 | NotificationeEV1DischProbAlTrap_1 | current | EEV1 disch. temp. probe | |
| 1.3.6.1.4.1.53332.1.0.152 | Notificationc2ThermAlTrap_1 | current | C2 Thermal alarm | |
| 1.3.6.1.4.1.53332.1.0.153 | Notificationc2HighPresAlTrap_1 | current | C2 High pressure alarm | |
| 1.3.6.1.4.1.53332.1.0.154 | Notificationc2LowPresAlTrap_1 | current | C2 Low pressure alarm | |
| 1.3.6.1.4.1.53332.1.0.155 | Notificationc2HighDischAlTrap_1 | current | C2 High discharge alarm | |
| 1.3.6.1.4.1.53332.1.0.156 | Notificationc2LCompRatAlTrap_1 | current | C2 low compresion alarm | |
| 1.3.6.1.4.1.53332.1.0.157 | Notificationcondenser2AlTrap_1 | current | Condenser 2 general alarm | |
| 1.3.6.1.4.1.53332.1.0.158 | Notificationc2WatFlowAlTrap_1 | current | Condenser 2 flow alarm | |
| 1.3.6.1.4.1.53332.1.0.159 | NotificationeEV2GenAlTrap_1 | current | EEV2 general alarm | |
| 1.3.6.1.4.1.53332.1.0.160 | NotificationeEV2CommAlTrap_1 | current | EEV2 communication alarm | |
| 1.3.6.1.4.1.53332.1.0.161 | NotificationeEV2SuctProbAlTrap_1 | current | EEV2 suction temp. probe | |
| 1.3.6.1.4.1.53332.1.0.162 | NotificationeEV2EvapProbAlTrap_1 | current | EEV2 evap. temp. probe | |
| 1.3.6.1.4.1.53332.1.0.163 | NotificationeEV2CondProbAlTrap_1 | current | EEV2 condens. temp. probe | |
| 1.3.6.1.4.1.53332.1.0.164 | NotificationeEV2DischProbAlTrap_1 | current | EEV2 disch. temp. probe | |
| 1.3.6.1.4.1.53332.1.0.165 | NotificationintHumidGenAlTrap_1 | current | Internal humidifier alarm | |
| 1.3.6.1.4.1.53332.1.0.166 | NotificationcPYCommAlTrap_1 | current | Communication alarm | |
| 1.3.6.1.4.1.53332.1.0.167 | NotificationcPYMemoryAlTrap_1 | current | Memory error alarm | |
| 1.3.6.1.4.1.53332.1.0.168 | NotificationcPYParameterAlTrap_1 | current | Parameters error alarm | |
| 1.3.6.1.4.1.53332.1.0.169 | NotificationcPYHighCurrAlTrap_1 | current | Electrodes high current | |
| 1.3.6.1.4.1.53332.1.0.170 | NotificationcPYLowSteamAlTrap_1 | current | Low steam product. alarm | |
| 1.3.6.1.4.1.53332.1.0.171 | NotificationcPYDrainAlTrap_1 | current | Drain loss alarm | |
| 1.3.6.1.4.1.53332.1.0.172 | NotificationcPYMaintAlTrap_1 | current | Maintenance hours alarm | |
| 1.3.6.1.4.1.53332.1.0.173 | NotificationcPYNoWaterAlTrap_1 | current | Water loss alarm | |
| 1.3.6.1.4.1.53332.1.0.174 | NotificationcPYCylMaintAlTrap_1 | current | Cylinder mainten. alarm | |
| 1.3.6.1.4.1.53332.1.0.175 | NotificationcPYDirtyCylAlTrap_1 | current | Exaust cylinder alarm | |
| 1.3.6.1.4.1.53332.1.0.176 | NotificationcPYFoamAlTrap_1 | current | Foam presence alarm | |
| 1.3.6.1.4.1.53332.1.0.177 | NotificationcPYLifeTimeAlTrap_1 | current | Life time expired alarm | |
| 1.3.6.1.4.1.53332.1.0.178 | NotificationcPYHighWatLevAlTrap_1 | current | High water level alarm | |
| 1.3.6.1.4.1.53332.1.0.179 | NotificationcPYHWatCondAlTrap_1 | current | High conductivity alarm | |
| 1.3.6.1.4.1.53332.1.0.180 | NotificationcPYConnectionAlTrap_1 | current | Connection error alarm | |
| 1.3.6.1.4.1.53332.1.0.181 | NotificationwatPresAlTrap_1 | current | Water presence alarm | |
| 1.3.6.1.4.1.53332.1.0.182 | NotificationdrainPumpAlTrap_1 | current | Drain pump alarm | |
| 1.3.6.1.4.1.53332.1.0.183 | NotificationelHeatAlTrap_1 | current | Electric heater alarm | |
| 1.3.6.1.4.1.53332.1.0.184 | NotificationfilterAlTrap_1 | current | Dirty filter alarm | |
| 1.3.6.1.4.1.53332.1.0.185 | NotificationdryCoolerAlTrap_1 | current | Dry cooler alarm | |
| 1.3.6.1.4.1.53332.1.0.186 | NotificationextHumidAlTrap_1 | current | External humidifier alarm | |
| 1.3.6.1.4.1.53332.1.0.187 | NotificationwaterPumpAlTrap_1 | current | Water pump alarm | |
| 1.3.6.1.4.1.53332.1.0.188 | NotificationcondUnitGenAlTrap_1 | current | Motocondenser alarm | |
| 1.3.6.1.4.1.53332.1.0.189 | NotificationgasLeakAlTrap_1 | current | Refrigerant leak alarm | |
| 1.3.6.1.4.1.53332.1.0.190 | NotificationpowerSupplyAlTrap_1 | current | Power fault alarm | |
| 1.3.6.1.4.1.53332.1.0.191 | NotificationgenericSoftAlTrap_1 | current | Not critical generic al. | |
| 1.3.6.1.4.1.53332.1.0.192 | NotificationlocalNetworkAlTrap_1 | current | Local network alarm | |
| 1.3.6.1.4.1.53332.1.0.193 | NotificationregHighTempAlTrap_1 | current | High regulation T.alarm | |
| 1.3.6.1.4.1.53332.1.0.194 | NotificationregLowTempAlTrap_1 | current | Low regulation T.alarm | |
| 1.3.6.1.4.1.53332.1.0.195 | NotificationhighLimTempAlTrap_1 | current | High limit temp. alarm | |
| 1.3.6.1.4.1.53332.1.0.196 | NotificationlowLimTempAlTrap_1 | current | Low limit temp. alarm | |
| 1.3.6.1.4.1.53332.1.0.197 | NotificationretHighHumiAlTrap_1 | current | High room humidity alarm | |
| 1.3.6.1.4.1.53332.1.0.198 | NotificationretLowHumiAlTrap_1 | current | Low room humidity alarm | |
| 1.3.6.1.4.1.53332.1.0.199 | NotificationsupHighHumiAlTrap_1 | current | High supp.humidity alarm | |
| 1.3.6.1.4.1.53332.1.0.200 | NotificationsupLowHumiAlTrap_1 | current | Low supp.humidity alarm | |
| 1.3.6.1.4.1.53332.1.0.201 | NotificationprobeMod1COMTrap_1 | current | Module 1 communication | |
| 1.3.6.1.4.1.53332.1.0.202 | NotificationprobeMod1err1Trap_1 | current | Module 1 probe 1 alarm | |
| 1.3.6.1.4.1.53332.1.0.203 | NotificationprobeMod1err2Trap_1 | current | Module 1 probe 2 alarm | |
| 1.3.6.1.4.1.53332.1.0.204 | NotificationprobeMod1err3Trap_1 | current | Module 1 probe 3 alarm | |
| 1.3.6.1.4.1.53332.1.0.205 | NotificationprobeMod1err4Trap_1 | current | Module 1 probe 4 alarm | |
| 1.3.6.1.4.1.53332.1.0.206 | NotificationprobeMod1err5Trap_1 | current | Module 1 probe 5 alarm | |
| 1.3.6.1.4.1.53332.1.0.207 | NotificationprobeMod1err6Trap_1 | current | Module 1 probe 6 alarm | |
| 1.3.6.1.4.1.53332.1.0.208 | NotificationprobeMod2COMTrap_1 | current | Module 2 communication | |
| 1.3.6.1.4.1.53332.1.0.209 | NotificationprobeMod2err1Trap_1 | current | Module 2 probe 1 alarm | |
| 1.3.6.1.4.1.53332.1.0.210 | NotificationprobeMod2err2Trap_1 | current | Module 2 probe 2 alarm | |
| 1.3.6.1.4.1.53332.1.0.211 | NotificationprobeMod2err3Trap_1 | current | Module 2 probe 3 alarm | |
| 1.3.6.1.4.1.53332.1.0.212 | NotificationprobeMod2err4Trap_1 | current | Module 2 probe 4 alarm | |
| 1.3.6.1.4.1.53332.1.0.213 | NotificationprobeMod2err5Trap_1 | current | Module 2 probe 5 alarm | |
| 1.3.6.1.4.1.53332.1.0.214 | NotificationprobeMod2err6Trap_1 | current | Module 2 probe 6 alarm | |
| 1.3.6.1.4.1.53332.1.0.215 | NotificationprobeMod3COMTrap_1 | current | Module 3 communication | |
| 1.3.6.1.4.1.53332.1.0.216 | NotificationprobeMod3err1Trap_1 | current | Module 3 probe 1 alarm | |
| 1.3.6.1.4.1.53332.1.0.217 | NotificationprobeMod3err2Trap_1 | current | Module 3 probe 2 alarm | |
| 1.3.6.1.4.1.53332.1.0.218 | NotificationprobeMod3err3Trap_1 | current | Module 3 probe 3 alarm | |
| 1.3.6.1.4.1.53332.1.0.219 | NotificationprobeMod3err4Trap_1 | current | Module 3 probe 4 alarm | |
| 1.3.6.1.4.1.53332.1.0.220 | NotificationprobeMod3err5Trap_1 | current | Module 3 probe 5 alarm | |
| 1.3.6.1.4.1.53332.1.0.221 | NotificationprobeMod3err6Trap_1 | current | Module 3 probe 6 alarm | |
| 1.3.6.1.4.1.53332.1.1 | NodebinaryObjects1 | |||
| 1.3.6.1.4.1.53332.1.1.1 | ScalardamperStatusDI_1 | read-only | current | Motorised damper status |
| 1.3.6.1.4.1.53332.1.1.2 | ScalardirtyFilterDI_1 | read-only | current | Dirty filter alarm |
| 1.3.6.1.4.1.53332.1.1.3 | ScalarremoteOffDI_1 | read-only | current | Remote OFF status |
| 1.3.6.1.4.1.53332.1.1.4 | ScalarelHeaterAlarmDI_1 | read-only | current | Heater thermostat alarm |
| 1.3.6.1.4.1.53332.1.1.5 | ScalarcondPumpAlarmDI_1 | read-only | current | Condensate pump alarm |
| 1.3.6.1.4.1.53332.1.1.6 | ScalarconfigurableDI1_1 | read-only | current | Configurable DI 1 |
| 1.3.6.1.4.1.53332.1.1.7 | ScalarconfigurableDI2_1 | read-only | current | Configurable DI 2 |
| 1.3.6.1.4.1.53332.1.1.8 | ScalarconfigurableDI3_1 | read-only | current | Configurable DI 3 |
| 1.3.6.1.4.1.53332.1.1.9 | ScalarconfigurableDI4_1 | read-only | current | Configurable DI 4 |
| 1.3.6.1.4.1.53332.1.1.10 | ScalarconfigurableDI5_1 | read-only | current | Configurable DI 5 |
| 1.3.6.1.4.1.53332.1.1.11 | Scalarc1ThermAlarmDI_1 | read-only | current | Comp1 thermal alarm |
| 1.3.6.1.4.1.53332.1.1.12 | Scalarc1HPAlarmDI_1 | read-only | current | Comp1 high pressure alarm |
| 1.3.6.1.4.1.53332.1.1.13 | Scalarc1LPAlarmDI_1 | read-only | current | Comp1 low pressure alarm |
| 1.3.6.1.4.1.53332.1.1.14 | Scalarc2ThermAlarmDI_1 | read-only | current | Comp2 thermal alarm |
| 1.3.6.1.4.1.53332.1.1.15 | Scalarc2HPAlarmDI_1 | read-only | current | Comp2 high pressure alarm |
| 1.3.6.1.4.1.53332.1.1.16 | Scalarc2LPAlarmDI_1 | read-only | current | Comp2 low pressure alarm |
| 1.3.6.1.4.1.53332.1.1.17 | ScalarfansDO_1 | read-only | current | Fan control |
| 1.3.6.1.4.1.53332.1.1.18 | ScalardamperDO_1 | read-only | current | Motorised dampers control |
| 1.3.6.1.4.1.53332.1.1.19 | ScalarconfigurableDO1_1 | read-only | current | Configurable DO 1 |
| 1.3.6.1.4.1.53332.1.1.20 | ScalarconfigurableDO2_1 | read-only | current | Configurable DO 2 |
| 1.3.6.1.4.1.53332.1.1.21 | ScalarconfigurableDO3_1 | read-only | current | Configurable DO 3 |
| 1.3.6.1.4.1.53332.1.1.22 | ScalarconfigurableDO4_1 | read-only | current | Configurable DO 4 |
| 1.3.6.1.4.1.53332.1.1.23 | ScalarconfigurableDO5_1 | read-only | current | Configurable DO 5 |
| 1.3.6.1.4.1.53332.1.1.24 | ScalareHeaterStage1DO_1 | read-only | current | Electric heat stage 1 |
| 1.3.6.1.4.1.53332.1.1.25 | ScalareHeaterStage2DO_1 | read-only | current | Electric heat stage 2 |
| 1.3.6.1.4.1.53332.1.1.26 | Scalarcompressor1DO_1 | read-only | current | Compressor 1 control |
| 1.3.6.1.4.1.53332.1.1.27 | Scalarcompressor2DO_1 | read-only | current | Compressor 2 control |
| 1.3.6.1.4.1.53332.1.1.28 | ScalarhumPowerDO_1 | read-only | current | Humidifier control |
| 1.3.6.1.4.1.53332.1.1.29 | ScalarhumDrainValveDO_1 | read-only | current | Humidifier Discharge |
| 1.3.6.1.4.1.53332.1.1.30 | ScalarhumFillValveDO_1 | read-only | current | Humidifier Charging |
| 1.3.6.1.4.1.53332.1.1.31 | ScalarhumWaterLevel_1 | read-only | current | Humidifier high water |
| 1.3.6.1.4.1.53332.1.1.32 | ScalarsupervOFF_1 | read-write | current | ON/OFF from supervisor |
| 1.3.6.1.4.1.53332.1.1.33 | ScalarenableHumid_1 | read-write | current | Humidification enabling |
| 1.3.6.1.4.1.53332.1.1.34 | ScalarhumManualDrain_1 | read-write | current | Manual draining |
| 1.3.6.1.4.1.53332.1.1.35 | ScalarhumCylWashing_1 | read-write | current | Cylinder washing |
| 1.3.6.1.4.1.53332.1.1.36 | ScalartSManExchange_1 | read-write | current | TS manual exchange |
| 1.3.6.1.4.1.53332.1.1.37 | ScalartSTempExchEnab_1 | read-write | current | Enable TS room temp. exc. |
| 1.3.6.1.4.1.53332.1.1.38 | ScalardamperAlRes_1 | read-write | current | Reset damper status AL |
| 1.3.6.1.4.1.53332.1.1.39 | ScalarfireSmokeAlRes_1 | read-write | current | Reset smoke/fire AL |
| 1.3.6.1.4.1.53332.1.1.40 | ScalargenSerAlRes_1 | read-write | current | Reset generic serious AL |
| 1.3.6.1.4.1.53332.1.1.41 | ScalarfansGenAlRes_1 | read-write | current | Reset supply fan AL |
| 1.3.6.1.4.1.53332.1.1.42 | Scalarf1InvAlRes_1 | read-write | current | Reset fan 1 alarm |
| 1.3.6.1.4.1.53332.1.1.43 | Scalarf2InvAlRes_1 | read-write | current | Reset fan 2 alarm |
| 1.3.6.1.4.1.53332.1.1.44 | Scalarf3InvAlRes_1 | read-write | current | Reset fan 3 alarm |
| 1.3.6.1.4.1.53332.1.1.45 | Scalarf4InvAlRes_1 | read-write | current | Reset fan 4 alarm |
| 1.3.6.1.4.1.53332.1.1.46 | Scalarf5InvAlRes_1 | read-write | current | Reset fan 5 alarm |
| 1.3.6.1.4.1.53332.1.1.47 | Scalarf6InvAlRes_1 | read-write | current | Reset fan 6 alarm |
| 1.3.6.1.4.1.53332.1.1.48 | Scalarf7InvAlRes_1 | read-write | current | Reset fan 7 alarm |
| 1.3.6.1.4.1.53332.1.1.49 | Scalarf8InvAlRes_1 | read-write | current | Reset fan 8 alarm |
| 1.3.6.1.4.1.53332.1.1.50 | Scalarf9InvAlRes_1 | read-write | current | Reset fan 9 alarm |
| 1.3.6.1.4.1.53332.1.1.51 | Scalarf10InvAlRes_1 | read-write | current | Reset fan 10 alarm |
| 1.3.6.1.4.1.53332.1.1.52 | ScalarinvCompAlRes_1 | read-write | current | Reset inverter alarm |
| 1.3.6.1.4.1.53332.1.1.53 | Scalarc1ThermAlRes_1 | read-write | current | Reset C1 thermal AL |
| 1.3.6.1.4.1.53332.1.1.54 | Scalarc1HighPresAlRes_1 | read-write | current | Reset C1 high pressure AL |
| 1.3.6.1.4.1.53332.1.1.55 | Scalarc1LowPresAlRes_1 | read-write | current | Reset C1 low pressure AL |
| 1.3.6.1.4.1.53332.1.1.56 | Scalarc1HighDisTAlRes_1 | read-write | current | Reset C1 high disch. AL |
| 1.3.6.1.4.1.53332.1.1.57 | Scalarc1LCompRatAlRes_1 | read-write | current | Reset C1 low compres. AL |
| 1.3.6.1.4.1.53332.1.1.58 | Scalarcondenser1AlRes_1 | read-write | current | Reset condenser 1 AL |
| 1.3.6.1.4.1.53332.1.1.59 | ScalareEV1AlRes_1 | read-write | current | Reset EEV1 alarm |
| 1.3.6.1.4.1.53332.1.1.60 | Scalarc2ThermAlRes_1 | read-write | current | Reset C2 thermal AL |
| 1.3.6.1.4.1.53332.1.1.61 | Scalarc2HighPresAlRes_1 | read-write | current | Reset C2 high pressure AL |
| 1.3.6.1.4.1.53332.1.1.62 | Scalarc2LowPresAlRes_1 | read-write | current | Reset C2 low pressure AL |
| 1.3.6.1.4.1.53332.1.1.63 | Scalarc2HighDisTAlRes_1 | read-write | current | Reset C2 high disch. AL |
| 1.3.6.1.4.1.53332.1.1.64 | Scalarc2LComRatAlRes_1 | read-write | current | Reset C2 low compres. AL |
| 1.3.6.1.4.1.53332.1.1.65 | Scalarcondenser2AlRes_1 | read-write | current | Reset condenser 2 AL |
| 1.3.6.1.4.1.53332.1.1.66 | ScalareEV2AlRes_1 | read-write | current | Reset EEV2 alarm |
| 1.3.6.1.4.1.53332.1.1.67 | ScalarintHumidifAlRes_1 | read-write | current | Reset int. humidifier AL |
| 1.3.6.1.4.1.53332.1.1.68 | ScalarwatPresAlRes_1 | read-write | current | Reset water presence AL |
| 1.3.6.1.4.1.53332.1.1.69 | ScalardrainPumpAlRes_1 | read-write | current | Reset drain pump AL |
| 1.3.6.1.4.1.53332.1.1.70 | ScalarelHeatAlRes_1 | read-write | current | Reset electric heater AL |
| 1.3.6.1.4.1.53332.1.1.71 | ScalarfilterAlRes_1 | read-write | current | Reset dirty filter AL |
| 1.3.6.1.4.1.53332.1.1.72 | ScalardryCoolerAlRes_1 | read-write | current | Reset dry cooler AL |
| 1.3.6.1.4.1.53332.1.1.73 | ScalarextHumidifAlRes_1 | read-write | current | Reset ext. humidifier AL |
| 1.3.6.1.4.1.53332.1.1.74 | ScalarwaterPumpAlRes_1 | read-write | current | Reset water pump AL |
| 1.3.6.1.4.1.53332.1.1.75 | ScalarcondUnitGAlRes_1 | read-write | current | Reset motocondenser AL |
| 1.3.6.1.4.1.53332.1.1.76 | ScalargasLeakAlRes_1 | read-write | current | Reset gas leak AL |
| 1.3.6.1.4.1.53332.1.1.77 | ScalarpowerSupAlRes_1 | read-write | current | Reset power fault AL |
| 1.3.6.1.4.1.53332.1.1.78 | ScalargenSoftAlRes_1 | read-write | current | Reset generic soft AL |
| 1.3.6.1.4.1.53332.1.2 | NodescalarsObjects1 | |||
| 1.3.6.1.4.1.53332.1.2.1 | ScalarconfDI1Combo_1 | read-only | current | Configurable DI1 meaning |
| 1.3.6.1.4.1.53332.1.2.2 | ScalarconfDI2Combo_1 | read-only | current | Configurable DI2 meaning |
| 1.3.6.1.4.1.53332.1.2.3 | ScalarconfDI3Combo_1 | read-only | current | Configurable DI3 meaning |
| 1.3.6.1.4.1.53332.1.2.4 | ScalarconfDI4Combo_1 | read-only | current | Configurable DI4 meaning |
| 1.3.6.1.4.1.53332.1.2.5 | ScalarconfDI5Combo_1 | read-only | current | Configurable DI5 meaning |
| 1.3.6.1.4.1.53332.1.2.6 | ScalarconfDO1Combo_1 | read-only | current | Configurable DO1 meaning |
| 1.3.6.1.4.1.53332.1.2.7 | ScalarconfDO2Combo_1 | read-only | current | Configurable DO2 meaning |
| 1.3.6.1.4.1.53332.1.2.8 | ScalarconfDO3Combo_1 | read-only | current | Configurable DO3 meaning |
| 1.3.6.1.4.1.53332.1.2.9 | ScalarconfDO4Combo_1 | read-only | current | Configurable DO4 meaning |
| 1.3.6.1.4.1.53332.1.2.10 | ScalarconfDO5Combo_1 | read-only | current | Configurable DO5 meaning |
| 1.3.6.1.4.1.53332.1.2.11 | ScalarreturnTemp_1 | read-only | current | Return temperature |
| 1.3.6.1.4.1.53332.1.2.12 | ScalarreturnTAvg_1 | read-only | current | Return temperature (AVG) |
| 1.3.6.1.4.1.53332.1.2.13 | ScalarsupplyTemp_1 | read-only | current | Supply temperature |
| 1.3.6.1.4.1.53332.1.2.14 | ScalarsupplyTAvg_1 | read-only | current | Supply temperature (AVG) |
| 1.3.6.1.4.1.53332.1.2.15 | ScalartempDelta_1 | read-only | current | Temperature delta |
| 1.3.6.1.4.1.53332.1.2.16 | ScalarreturnHumidity_1 | read-only | current | Return humidity |
| 1.3.6.1.4.1.53332.1.2.17 | ScalarreturnHumAvg_1 | read-only | current | Return humidity (AVG) |
| 1.3.6.1.4.1.53332.1.2.18 | ScalarsupplyHumidity_1 | read-only | current | Supply humidity |
| 1.3.6.1.4.1.53332.1.2.19 | ScalarsupplyHumAvg_1 | read-only | current | Supply humidity (AVG) |
| 1.3.6.1.4.1.53332.1.2.20 | ScalarairFlow_1 | read-only | current | Air flow |
| 1.3.6.1.4.1.53332.1.2.22 | ScalarairPressure_1 | read-only | current | Air pressure |
| 1.3.6.1.4.1.53332.1.2.23 | ScalarairPressureAvg_1 | read-only | current | Air pressure (Average) |
| 1.3.6.1.4.1.53332.1.2.24 | ScalarnetMod1Combo1_1 | read-only | current | Module 1 - Probe 1 status |
| 1.3.6.1.4.1.53332.1.2.25 | ScalarnetMod1Probe1_1 | read-only | current | Module 1 - Probe 1 value |
| 1.3.6.1.4.1.53332.1.2.26 | ScalarnetMod1Combo2_1 | read-only | current | Module 1 - Probe 2 status |
| 1.3.6.1.4.1.53332.1.2.27 | ScalarnetMod1Probe2_1 | read-only | current | Module 1 - Probe 2 value |
| 1.3.6.1.4.1.53332.1.2.28 | ScalarnetMod1Combo3_1 | read-only | current | Module 1 - Probe 3 status |
| 1.3.6.1.4.1.53332.1.2.29 | ScalarnetMod1Probe3_1 | read-only | current | Module 1 - Probe 3 value |
| 1.3.6.1.4.1.53332.1.2.30 | ScalarnetMod1Combo4_1 | read-only | current | Module 1 - Probe 4 status |
| 1.3.6.1.4.1.53332.1.2.31 | ScalarnetMod1Probe4_1 | read-only | current | Module 1 - Probe 4 value |
| 1.3.6.1.4.1.53332.1.2.32 | ScalarnetMod1Combo5_1 | read-only | current | Module 1 - Probe 5 status |
| 1.3.6.1.4.1.53332.1.2.33 | ScalarnetMod1Probe5_1 | read-only | current | Module 1 - Probe 5 value |
| 1.3.6.1.4.1.53332.1.2.34 | ScalarnetMod1Combo6_1 | read-only | current | Module 1 - Probe 6 status |
| 1.3.6.1.4.1.53332.1.2.35 | ScalarnetMod1Probe6_1 | read-only | current | Module 1 - Probe 6 value |
| 1.3.6.1.4.1.53332.1.2.36 | ScalarnetMod2Combo1_1 | read-only | current | Module 2 - Probe 1 status |
| 1.3.6.1.4.1.53332.1.2.37 | ScalarnetMod2Probe1_1 | read-only | current | Module 2 - Probe 1 value |
| 1.3.6.1.4.1.53332.1.2.38 | ScalarnetMod2Combo2_1 | read-only | current | Module 2 - Probe 2 status |
| 1.3.6.1.4.1.53332.1.2.39 | ScalarnetMod2Probe2_1 | read-only | current | Module 2 - Probe 2 value |
| 1.3.6.1.4.1.53332.1.2.40 | ScalarnetMod2Combo3_1 | read-only | current | Module 2 - Probe 3 status |
| 1.3.6.1.4.1.53332.1.2.41 | ScalarnetMod2Probe3_1 | read-only | current | Module 2 - Probe 3 value |
| 1.3.6.1.4.1.53332.1.2.42 | ScalarnetMod2Combo4_1 | read-only | current | Module 2 - Probe 4 status |
| 1.3.6.1.4.1.53332.1.2.43 | ScalarnetMod2Probe4_1 | read-only | current | Module 2 - Probe 4 value |
| 1.3.6.1.4.1.53332.1.2.44 | ScalarnetMod2Combo5_1 | read-only | current | Module 2 - Probe 5 status |
| 1.3.6.1.4.1.53332.1.2.45 | ScalarnetMod2Probe5_1 | read-only | current | Module 2 - Probe 5 value |
| 1.3.6.1.4.1.53332.1.2.46 | ScalarnetMod2Combo6_1 | read-only | current | Module 2 - Probe 6 status |
| 1.3.6.1.4.1.53332.1.2.47 | ScalarnetMod2Probe6_1 | read-only | current | Module 2 - Probe 6 value |
| 1.3.6.1.4.1.53332.1.2.48 | ScalarnetMod3Combo1_1 | read-only | current | Module 3 - Probe 1 status |
| 1.3.6.1.4.1.53332.1.2.49 | ScalarnetMod3Probe1_1 | read-only | current | Module 3 - Probe 1 value |
| 1.3.6.1.4.1.53332.1.2.50 | ScalarnetMod3Combo2_1 | read-only | current | Module 3 - Probe 2 status |
| 1.3.6.1.4.1.53332.1.2.51 | ScalarnetMod3Probe2_1 | read-only | current | Module 3 - Probe 2 value |
| 1.3.6.1.4.1.53332.1.2.52 | ScalarnetMod3Combo3_1 | read-only | current | Module 3 - Probe 3 status |
| 1.3.6.1.4.1.53332.1.2.53 | ScalarnetMod3Probe3_1 | read-only | current | Module 3 - Probe 3 value |
| 1.3.6.1.4.1.53332.1.2.54 | ScalarnetMod3Combo4_1 | read-only | current | Module 3 - Probe 4 status |
| 1.3.6.1.4.1.53332.1.2.55 | ScalarnetMod3Probe4_1 | read-only | current | Module 3 - Probe 4 value |
| 1.3.6.1.4.1.53332.1.2.56 | ScalarnetMod3Combo5_1 | read-only | current | Module 3 - Probe 5 status |
| 1.3.6.1.4.1.53332.1.2.57 | ScalarnetMod3Probe5_1 | read-only | current | Module 3 - Probe 5 value |
| 1.3.6.1.4.1.53332.1.2.58 | ScalarnetMod3Combo6_1 | read-only | current | Module 3 - Probe 6 status |
| 1.3.6.1.4.1.53332.1.2.59 | ScalarnetMod3Probe6_1 | read-only | current | Module 3 - Probe 6 value |
| 1.3.6.1.4.1.53332.1.2.60 | ScalaravgModTemp_1 | read-only | current | Modules temperatures AVG |
| 1.3.6.1.4.1.53332.1.2.61 | ScalaravgModHumi_1 | read-only | current | Modules humidity AVG |
| 1.3.6.1.4.1.53332.1.2.62 | ScalaravgModPress_1 | read-only | current | Modules pressure AVG |
| 1.3.6.1.4.1.53332.1.2.63 | ScalardryCoolerAO_1 | read-only | current | Supply Fan/Dry cooler |
| 1.3.6.1.4.1.53332.1.2.64 | ScalarcoolingAO_1 | read-only | current | Cooling valve/FC/Inverter |
| 1.3.6.1.4.1.53332.1.2.65 | ScalarheatingAO_1 | read-only | current | Heating valve/Heater |
| 1.3.6.1.4.1.53332.1.2.66 | ScalartwoSources2AO_1 | read-only | current | TS cooling valve 2 |
| 1.3.6.1.4.1.53332.1.2.67 | Scalarcondenser1AO_1 | read-only | current | Condenser 1 |
| 1.3.6.1.4.1.53332.1.2.68 | Scalarcond2HumidifAO_1 | read-only | current | Condenser 2/Humidifier |
| 1.3.6.1.4.1.53332.1.2.69 | ScalarunitStatus_1 | read-only | current | Unit status |
| 1.3.6.1.4.1.53332.1.2.70 | ScalarfanSpeed_1 | read-only | current | Fan speed |
| 1.3.6.1.4.1.53332.1.2.71 | Scalarfan1Actspeed_1 | read-only | current | Fan 1 speed |
| 1.3.6.1.4.1.53332.1.2.72 | Scalarfan1ActRPM_1 | read-only | current | Fan 1 speed RPM |
| 1.3.6.1.4.1.53332.1.2.73 | Scalarfan1Cur_1 | read-only | current | Fan 1 current |
| 1.3.6.1.4.1.53332.1.2.74 | Scalarfan1Power_1 | read-only | current | Fan 1 power |
| 1.3.6.1.4.1.53332.1.2.75 | Scalarfan2Actspeed_1 | read-only | current | Fan 2 speed |
| 1.3.6.1.4.1.53332.1.2.76 | Scalarfan2ActRPM_1 | read-only | current | Fan 2 speed RPM |
| 1.3.6.1.4.1.53332.1.2.77 | Scalarfan2Cur_1 | read-only | current | Fan 2 current |
| 1.3.6.1.4.1.53332.1.2.78 | Scalarfan2Power_1 | read-only | current | Fan 2 power |
| 1.3.6.1.4.1.53332.1.2.79 | Scalarfan3Actspeed_1 | read-only | current | Fan 3 speed |
| 1.3.6.1.4.1.53332.1.2.80 | Scalarfan3ActRPM_1 | read-only | current | Fan 3 speed RPM |
| 1.3.6.1.4.1.53332.1.2.81 | Scalarfan3Cur_1 | read-only | current | Fan 3 current |
| 1.3.6.1.4.1.53332.1.2.82 | Scalarfan3Power_1 | read-only | current | Fan 3 power |
| 1.3.6.1.4.1.53332.1.2.83 | Scalarfan4Actspeed_1 | read-only | current | Fan 4 speed |
| 1.3.6.1.4.1.53332.1.2.84 | Scalarfan4ActRPM_1 | read-only | current | Fan 4 speed RPM |
| 1.3.6.1.4.1.53332.1.2.85 | Scalarfan4Cur_1 | read-only | current | Fan 4 current |
| 1.3.6.1.4.1.53332.1.2.86 | Scalarfan4Power_1 | read-only | current | Fan 4 power |
| 1.3.6.1.4.1.53332.1.2.87 | Scalarfan5Actspeed_1 | read-only | current | Fan 5 speed |
| 1.3.6.1.4.1.53332.1.2.88 | Scalarfan5ActRPM_1 | read-only | current | Fan 5 speed RPM |
| 1.3.6.1.4.1.53332.1.2.89 | Scalarfan5Cur_1 | read-only | current | Fan 5 current |
| 1.3.6.1.4.1.53332.1.2.90 | Scalarfan5Power_1 | read-only | current | Fan 5 power |
| 1.3.6.1.4.1.53332.1.2.91 | Scalarfan6Actspeed_1 | read-only | current | Fan 6 speed |
| 1.3.6.1.4.1.53332.1.2.92 | Scalarfan6ActRPM_1 | read-only | current | Fan 6 speed RPM |
| 1.3.6.1.4.1.53332.1.2.93 | Scalarfan6Cur_1 | read-only | current | Fan 6 current |
| 1.3.6.1.4.1.53332.1.2.94 | Scalarfan6Power_1 | read-only | current | Fan 6 power |
| 1.3.6.1.4.1.53332.1.2.95 | Scalarfan7Actspeed_1 | read-only | current | Fan 7 speed |
| 1.3.6.1.4.1.53332.1.2.96 | Scalarfan7ActRPM_1 | read-only | current | Fan 7 speed RPM |
| 1.3.6.1.4.1.53332.1.2.97 | Scalarfan7Cur_1 | read-only | current | Fan 7 current |
| 1.3.6.1.4.1.53332.1.2.98 | Scalarfan7Power_1 | read-only | current | Fan 7 power |
| 1.3.6.1.4.1.53332.1.2.99 | Scalarfan8Actspeed_1 | read-only | current | Fan 8 speed |
| 1.3.6.1.4.1.53332.1.2.100 | Scalarfan8ActRPM_1 | read-only | current | Fan 8 speed RPM |
| 1.3.6.1.4.1.53332.1.2.101 | Scalarfan8Cur_1 | read-only | current | Fan 8 current |
| 1.3.6.1.4.1.53332.1.2.102 | Scalarfan8Power_1 | read-only | current | Fan 8 power |
| 1.3.6.1.4.1.53332.1.2.103 | Scalarfan9Actspeed_1 | read-only | current | Fan 9 speed |
| 1.3.6.1.4.1.53332.1.2.104 | Scalarfan9ActRPM_1 | read-only | current | Fan 9 speed RPM |
| 1.3.6.1.4.1.53332.1.2.105 | Scalarfan9Cur_1 | read-only | current | Fan 9 current |
| 1.3.6.1.4.1.53332.1.2.106 | Scalarfan9Power_1 | read-only | current | Fan 9 power |
| 1.3.6.1.4.1.53332.1.2.107 | Scalarfan10Actspeed_1 | read-only | current | Fan 10 speed |
| 1.3.6.1.4.1.53332.1.2.108 | Scalarfan10ActRPM_1 | read-only | current | Fan 10 speed RPM |
| 1.3.6.1.4.1.53332.1.2.109 | Scalarfan10Cur_1 | read-only | current | Fan 10 current |
| 1.3.6.1.4.1.53332.1.2.110 | Scalarfan10Power_1 | read-only | current | Fan 10 power |
| 1.3.6.1.4.1.53332.1.2.111 | ScalardiffFilterPres_1 | read-only | current | Dirty filter pressure |
| 1.3.6.1.4.1.53332.1.2.112 | ScalarcoolingRequest_1 | read-only | current | Cooling request |
| 1.3.6.1.4.1.53332.1.2.113 | ScalarheatingRequest_1 | read-only | current | Heating request |
| 1.3.6.1.4.1.53332.1.2.114 | ScalardehumidRequest_1 | read-only | current | Dehumidification request |
| 1.3.6.1.4.1.53332.1.2.115 | ScalarhumidifRequest_1 | read-only | current | Humidification request |
| 1.3.6.1.4.1.53332.1.2.116 | ScalartempFcTs_1 | read-only | current | FC/TS temperature |
| 1.3.6.1.4.1.53332.1.2.117 | ScalarfCTSStatus_1 | read-only | current | FC/TS status |
| 1.3.6.1.4.1.53332.1.2.118 | ScalarfCRequest_1 | read-only | current | Free cooling request |
| 1.3.6.1.4.1.53332.1.2.119 | ScalaractiveComp_1 | read-only | current | Active compressor |
| 1.3.6.1.4.1.53332.1.2.120 | Scalarcomp1Sts_1 | read-only | current | Compressor 1 Status |
| 1.3.6.1.4.1.53332.1.2.121 | Scalarcomp2Sts_1 | read-only | current | Compressor 2 Status |
| 1.3.6.1.4.1.53332.1.2.122 | ScalarinvComprReq_1 | read-only | current | Inverter compressor request |
| 1.3.6.1.4.1.53332.1.2.123 | ScalarinvCompHz_1 | read-only | current | Inverter frequency |
| 1.3.6.1.4.1.53332.1.2.124 | ScalarinvCompPower_1 | read-only | current | Inverter power input |
| 1.3.6.1.4.1.53332.1.2.125 | ScalarinvCompCurrent_1 | read-only | current | Inverter absorbed current |
| 1.3.6.1.4.1.53332.1.2.126 | Scalarc1EvapPres_1 | read-only | current | C1 evaporation pressure |
| 1.3.6.1.4.1.53332.1.2.127 | Scalarc1EvapTemp_1 | read-only | current | C1 evaporation temperature |
| 1.3.6.1.4.1.53332.1.2.128 | Scalarc1SuctionTemp_1 | read-only | current | C1 suction temperature |
| 1.3.6.1.4.1.53332.1.2.129 | Scalarc1Superheat_1 | read-only | current | C1 super-heating |
| 1.3.6.1.4.1.53332.1.2.130 | Scalarc1CompRatio_1 | read-only | current | C1 compression ratio |
| 1.3.6.1.4.1.53332.1.2.131 | Scalarc1DischTemp_1 | read-only | current | C1 discharge temperature |
| 1.3.6.1.4.1.53332.1.2.132 | Scalarc1CondPress_1 | read-only | current | C1 condensation pressure |
| 1.3.6.1.4.1.53332.1.2.133 | Scalarc1CondTemp_1 | read-only | current | C1 condensation temperature |
| 1.3.6.1.4.1.53332.1.2.134 | Scalarc1Desuperheat_1 | read-only | current | C1 de-superheating |
| 1.3.6.1.4.1.53332.1.2.135 | Scalarc1LiquidTemp_1 | read-only | current | C1 liquid temperature |
| 1.3.6.1.4.1.53332.1.2.136 | Scalarc1Subcooling_1 | read-only | current | C1 sub-cooling |
| 1.3.6.1.4.1.53332.1.2.137 | ScalareEV1SHSet_1 | read-only | current | EEV1 super-heating set-point |
| 1.3.6.1.4.1.53332.1.2.138 | ScalareEV1Position_1 | read-only | current | EEV1 position |
| 1.3.6.1.4.1.53332.1.2.139 | ScalareEV1Status_1 | read-only | current | EEV1 working status |
| 1.3.6.1.4.1.53332.1.2.140 | Scalarcond1ActualSet_1 | read-only | current | Condenser 1 current set |
| 1.3.6.1.4.1.53332.1.2.141 | Scalarcond1Req_1 | read-only | current | Condenser 1 request |
| 1.3.6.1.4.1.53332.1.2.142 | Scalarc2EvapPres_1 | read-only | current | C2 evaporation pressure |
| 1.3.6.1.4.1.53332.1.2.143 | Scalarc2EvapTemp_1 | read-only | current | C2 evaporation temperature |
| 1.3.6.1.4.1.53332.1.2.144 | Scalarc2SuctionTemp_1 | read-only | current | C2 suction temperature |
| 1.3.6.1.4.1.53332.1.2.145 | Scalarc2Superheat_1 | read-only | current | C2 super-heating |
| 1.3.6.1.4.1.53332.1.2.146 | Scalarc2CompRatio_1 | read-only | current | C2 compression ratio |
| 1.3.6.1.4.1.53332.1.2.147 | Scalarc2DischTemp_1 | read-only | current | C2 discharge temperature |
| 1.3.6.1.4.1.53332.1.2.148 | Scalarc2CondPress_1 | read-only | current | C2 condensation pressure |
| 1.3.6.1.4.1.53332.1.2.149 | Scalarc2CondTemp_1 | read-only | current | C2 condensation temperature |
| 1.3.6.1.4.1.53332.1.2.150 | Scalarc2Desuperheat_1 | read-only | current | C2 de-superheating |
| 1.3.6.1.4.1.53332.1.2.151 | Scalarc2LiquidTemp_1 | read-only | current | C2 liquid temperature |
| 1.3.6.1.4.1.53332.1.2.152 | Scalarc2Subcooling_1 | read-only | current | C2 sub-cooling |
| 1.3.6.1.4.1.53332.1.2.153 | ScalareEV2SHSet_1 | read-only | current | EEV2 superheat set-point |
| 1.3.6.1.4.1.53332.1.2.154 | ScalareEV2Position_1 | read-only | current | EEV2 position |
| 1.3.6.1.4.1.53332.1.2.155 | ScalareEV2Status_1 | read-only | current | EEV2 working status |
| 1.3.6.1.4.1.53332.1.2.156 | Scalarcond2ActualSet_1 | read-only | current | Condenser 2 current set |
| 1.3.6.1.4.1.53332.1.2.157 | Scalarcond2Req_1 | read-only | current | Condenser 2 request |
| 1.3.6.1.4.1.53332.1.2.158 | ScalarwaterINTemp1_1 | read-only | current | Water IN temperature 1 |
| 1.3.6.1.4.1.53332.1.2.159 | ScalarwaterOUTTemp1_1 | read-only | current | Water OUT temperature 1 |
| 1.3.6.1.4.1.53332.1.2.160 | ScalarwaterDT1_1 | read-only | current | Water temperature delta 1 |
| 1.3.6.1.4.1.53332.1.2.161 | ScalarwaterFlow1_1 | read-only | current | Water flow rate 1 |
| 1.3.6.1.4.1.53332.1.2.162 | ScalaractWatFlowSet1_1 | read-only | current | Actual water flow set 1 |
| 1.3.6.1.4.1.53332.1.2.163 | ScalarwaterCoolCap1_1 | read-only | current | Water cooling capacity 1 |
| 1.3.6.1.4.1.53332.1.2.164 | ScalareER1_1 | read-only | current | EER 1 |
| 1.3.6.1.4.1.53332.1.2.165 | Scalarvalve1Position_1 | read-only | current | Water valve 1 position |
| 1.3.6.1.4.1.53332.1.2.166 | ScalarwaterINTemp2_1 | read-only | current | Water IN temperature 2 |
| 1.3.6.1.4.1.53332.1.2.167 | ScalarwaterOUTTemp2_1 | read-only | current | Water OUT temperature 2 |
| 1.3.6.1.4.1.53332.1.2.168 | ScalarwaterDT2_1 | read-only | current | Water temperature delta 2 |
| 1.3.6.1.4.1.53332.1.2.169 | ScalarwaterFlow2_1 | read-only | current | Water flow rate 2 |
| 1.3.6.1.4.1.53332.1.2.170 | ScalaractWatFlowSet2_1 | read-only | current | Actual water flow set 2 |
| 1.3.6.1.4.1.53332.1.2.171 | ScalarwaterCoolCap2_1 | read-only | current | Water cooling capacity 2 |
| 1.3.6.1.4.1.53332.1.2.172 | ScalareER2_1 | read-only | current | EER 2 |
| 1.3.6.1.4.1.53332.1.2.173 | Scalarvalve2Position_1 | read-only | current | Water valve 2 position |
| 1.3.6.1.4.1.53332.1.2.174 | ScalarhumSteamProd_1 | read-only | current | Current steam production |
| 1.3.6.1.4.1.53332.1.2.175 | ScalarhumWaterConduct_1 | read-only | current | Humidifier conductivity |
| 1.3.6.1.4.1.53332.1.2.176 | ScalarhumCurrent_1 | read-only | current | Humidifier abs. Current |
| 1.3.6.1.4.1.53332.1.2.177 | ScalarhumWorkingMode_1 | read-only | current | Humidifier operating mode |
| 1.3.6.1.4.1.53332.1.2.178 | ScalarhumWorkStatus_1 | read-only | current | Humidifier operating status |
| 1.3.6.1.4.1.53332.1.2.179 | ScalarheaterReq_1 | read-only | current | Electric heater request |
| 1.3.6.1.4.1.53332.1.2.180 | ScalarheaterActiveStg_1 | read-only | current | Number of active stages |
| 1.3.6.1.4.1.53332.1.2.181 | ScalarelHeaterPower_1 | read-only | current | Electric heater power |
| 1.3.6.1.4.1.53332.1.2.182 | ScalarheatValveReq_1 | read-only | current | Hot water valve request |
| 1.3.6.1.4.1.53332.1.2.183 | ScalardryCoolerActSet_1 | read-only | current | Current dry cooler set |
| 1.3.6.1.4.1.53332.1.2.184 | ScalardryCoolerReq_1 | read-only | current | Dry cooler request |
| 1.3.6.1.4.1.53332.1.2.185 | ScalarunitWH_1 | read-only | current | Unit working hours |
| 1.3.6.1.4.1.53332.1.2.186 | Scalarc1WH_1 | read-only | current | Compressor1 working hours |
| 1.3.6.1.4.1.53332.1.2.187 | Scalarc1Startup_1 | read-only | current | Compressor 1 startups |
| 1.3.6.1.4.1.53332.1.2.188 | Scalarc2WH_1 | read-only | current | Compressor2 working hours |
| 1.3.6.1.4.1.53332.1.2.189 | Scalarc2Startup_1 | read-only | current | Compressor 2 startups |
| 1.3.6.1.4.1.53332.1.2.190 | ScalarcoolValveWH_1 | read-only | current | Cooling working hours |
| 1.3.6.1.4.1.53332.1.2.191 | ScalarheatingWH_1 | read-only | current | Heating working hours |
| 1.3.6.1.4.1.53332.1.2.192 | ScalarhumidifWH_1 | read-only | current | Humidifier working hours |
| 1.3.6.1.4.1.53332.1.2.193 | ScalarfreeCoolWH_1 | read-only | current | FC working hours |
| 1.3.6.1.4.1.53332.1.2.194 | ScalardryCoolerWH_1 | read-only | current | Dry cooler working hours |
| 1.3.6.1.4.1.53332.1.2.195 | Scalarcond1WH_1 | read-only | current | Condenser1 working hours |
| 1.3.6.1.4.1.53332.1.2.196 | Scalarcond2WH_1 | read-only | current | Condenser2 working hours |
| 1.3.6.1.4.1.53332.1.2.197 | ScalartempSetpoint_1 | read-write | current | Temperature set-point |
| 1.3.6.1.4.1.53332.1.2.198 | ScalarhumSetpoint_1 | read-write | current | Humidity set-point |
| 1.3.6.1.4.1.53332.1.2.199 | ScalarairFlowSetpoint_1 | read-write | current | Air flow set-point |
| 1.3.6.1.4.1.53332.1.2.200 | ScalarairPresSetpoint_1 | read-write | current | Air pressure set-point |
| 1.3.6.1.4.1.53332.1.2.201 | ScalarairDTSetpoint_1 | read-write | current | Air temperature delta set |
| 1.3.6.1.4.1.53332.1.2.202 | ScalartempControlSel_1 | read-write | current | Regulation sensor |
| 1.3.6.1.4.1.53332.1.2.203 | ScalartempControlType_1 | read-write | current | Regulation type |
| 1.3.6.1.4.1.53332.1.2.204 | ScalartPropBand_1 | read-write | current | Proportional Band |
| 1.3.6.1.4.1.53332.1.2.205 | ScalartIntegralTime_1 | read-write | current | Integration time |
| 1.3.6.1.4.1.53332.1.2.206 | ScalartDerivativeTime_1 | read-write | current | Derivative time |
| 1.3.6.1.4.1.53332.1.2.207 | ScalarhighTAlOffset_1 | read-write | current | High temperature offset |
| 1.3.6.1.4.1.53332.1.2.208 | ScalarlowTAlOffset_1 | read-write | current | Low temperature offset |
| 1.3.6.1.4.1.53332.1.2.209 | ScalarhighLimitTThr_1 | read-write | current | High limit temp. thresh. |
| 1.3.6.1.4.1.53332.1.2.210 | ScalarhighLimitTMng_1 | read-write | current | High limit temp. managem. |
| 1.3.6.1.4.1.53332.1.2.211 | ScalarlowLimitTThr_1 | read-write | current | Low limit temp.thresh. |
| 1.3.6.1.4.1.53332.1.2.212 | ScalarlowLimitTMng_1 | read-write | current | Low limit temp. managem. |
| 1.3.6.1.4.1.53332.1.2.213 | ScalardehumPropBand_1 | read-write | current | Dehumid. proportion. band |
| 1.3.6.1.4.1.53332.1.2.214 | ScalarhumPropBand_1 | read-write | current | Humid. proportion. band |
| 1.3.6.1.4.1.53332.1.2.215 | ScalarhRetHAlOffset_1 | read-write | current | High humidity offset |
| 1.3.6.1.4.1.53332.1.2.216 | ScalarlRetHAlOffset_1 | read-write | current | Low humidity offset |
| 1.3.6.1.4.1.53332.1.2.217 | ScalarhighSupHumThr_1 | read-write | current | High supp. humidity thr. |
| 1.3.6.1.4.1.53332.1.2.218 | ScalarlowSupHumThr_1 | read-write | current | Low supp. humidity thr. |
| 1.3.6.1.4.1.53332.1.2.219 | ScalarfCDelta_1 | read-write | current | Free cooling delta |
| 1.3.6.1.4.1.53332.1.2.220 | ScalartSWaterSet_1 | read-write | current | Two sources set-point |
| 1.3.6.1.4.1.53332.1.2.221 | ScalartSWaterPropBand_1 | read-write | current | Two sources band |
| 1.3.6.1.4.1.53332.1.2.222 | ScalartSAirTempSet_1 | read-write | current | TS room temp. Exch. set |
| 1.3.6.1.4.1.53332.1.2.223 | ScalarcondSetpoint_1 | read-write | current | Condensation set-point |
| 1.3.6.1.4.1.53332.1.2.224 | ScalarcondPropoBand_1 | read-write | current | Condensation band |
| 1.3.6.1.4.1.53332.1.2.225 | ScalarcondSetIncrease_1 | read-write | current | Condensation set increase |
| 1.3.6.1.4.1.53332.1.2.226 | ScalarmaxCondSetpoint_1 | read-write | current | Maximum condensation set |
| 1.3.6.1.4.1.53332.1.2.227 | ScalardryCoolerSet_1 | read-write | current | Dry cooler set-point |
| 1.3.6.1.4.1.53332.1.2.228 | ScalardryCoolPropBand_1 | read-write | current | Dry cooler band |
| 1.3.6.1.4.1.53332.1.2.229 | ScalardryCoolSetIncr_1 | read-write | current | Dry Cooler set increase |
| 1.3.6.1.4.1.53332.1.2.230 | ScalarmaxDryCoolerSet_1 | read-write | current | Maximum dry Cooler set |
| 1.3.6.1.4.1.53332.1.2.231 | ScalardirtyFiltSet_1 | read-write | current | Dirty filter set-point |
| 1.3.6.1.4.1.53332.1.2.232 | ScalardirtyFiltDiff_1 | read-write | current | Dirty filter differential |
| 1.3.6.1.4.1.53332.1.2.233 | ScalarinvCompAlCode1_1 | read-only | current | DC Inverter alarm code 1 |
| 1.3.6.1.4.1.53332.1.2.234 | ScalarinvCompAlCode2_1 | read-only | current | DC Inverter alarm code 2 |
| 1.3.6.1.4.1.53332.1.2.235 | ScalarinvCompAlCode3_1 | read-only | current | DC Inverter alarm code 3 |
| 1.3.6.1.4.1.53332.1.2.236 | ScalarinvCompAlCode4_1 | read-only | current | DC Inverter alarm code 4 |
| 1.3.6.1.4.1.53332.1.2.237 | ScalarinvCompAlCode5_1 | read-only | current | DC Inverter alarm code 5 |
| 1.3.6.1.4.1.53332.1.3 | Nodealarms1 | |||
| 1.3.6.1.4.1.53332.1.3.1 | ScalargeneralAl_1 | read-only | current | General alarams |
| 1.3.6.1.4.1.53332.1.3.2 | ScalarnotCriticAl_1 | read-only | current | Not critical alarms |
| 1.3.6.1.4.1.53332.1.3.3 | ScalarcriticalAl_1 | read-only | current | Critical alarms |
| 1.3.6.1.4.1.53332.1.3.4 | ScalarfansAl_1 | read-only | current | Fans alarms |
| 1.3.6.1.4.1.53332.1.3.5 | ScalarcompAl_1 | read-only | current | Compressors alarms |
| 1.3.6.1.4.1.53332.1.3.6 | ScalartempAl_1 | read-only | current | Temperature alarms |
| 1.3.6.1.4.1.53332.1.3.7 | ScalarhumidityAl_1 | read-only | current | Humidity alarms |
| 1.3.6.1.4.1.53332.1.3.8 | ScalardamperAl_1 | read-only | current | Damper status alarm |
| 1.3.6.1.4.1.53332.1.3.9 | ScalarfireSmokeAl_1 | read-only | current | Fire/Smoke alarm |
| 1.3.6.1.4.1.53332.1.3.10 | ScalargSeriousAl_1 | read-only | current | Critical generic alarm |
| 1.3.6.1.4.1.53332.1.3.11 | ScalarfansGenAl_1 | read-only | current | General supply fans alarm |
| 1.3.6.1.4.1.53332.1.3.12 | Scalarf1GeneralAl_1 | read-only | current | Fan general alarm 1 |
| 1.3.6.1.4.1.53332.1.3.13 | Scalarf1PowerAl_1 | read-only | current | Phase failure/undervolt.1 |
| 1.3.6.1.4.1.53332.1.3.14 | Scalarf1CommAl_1 | read-only | current | Communication 1 |
| 1.3.6.1.4.1.53332.1.3.15 | Scalarf1HiTempAl_1 | read-only | current | Power mod overheated 1 |
| 1.3.6.1.4.1.53332.1.3.16 | Scalarf1NetComAl_1 | read-only | current | Master/Slave com. 1 |
| 1.3.6.1.4.1.53332.1.3.17 | Scalarf1InvRegAl_1 | read-only | current | Regulation module 1 |
| 1.3.6.1.4.1.53332.1.3.18 | Scalarf1HiMotTAl_1 | read-only | current | Motor overheated 1 |
| 1.3.6.1.4.1.53332.1.3.19 | Scalarf1HallSenAl_1 | read-only | current | Hall sensor error 1 |
| 1.3.6.1.4.1.53332.1.3.20 | Scalarf1OverlAl_1 | read-only | current | Locked motor 1 |
| 1.3.6.1.4.1.53332.1.3.21 | Scalarf1LowDCAl_1 | read-only | current | Low DC 1 |
| 1.3.6.1.4.1.53332.1.3.22 | Scalarf2GeneralAl_1 | read-only | current | Fan general alarm 2 |
| 1.3.6.1.4.1.53332.1.3.23 | Scalarf2PowerAl_1 | read-only | current | Phase failure/undervolt.2 |
| 1.3.6.1.4.1.53332.1.3.24 | Scalarf2CommAl_1 | read-only | current | Communication 2 |
| 1.3.6.1.4.1.53332.1.3.25 | Scalarf2HiTempAl_1 | read-only | current | Power mod overheated 2 |
| 1.3.6.1.4.1.53332.1.3.26 | Scalarf2NetComAl_1 | read-only | current | Master/Slave com. 2 |
| 1.3.6.1.4.1.53332.1.3.27 | Scalarf2InvRegAl_1 | read-only | current | Regulation module 2 |
| 1.3.6.1.4.1.53332.1.3.28 | Scalarf2HiMotTAl_1 | read-only | current | Motor overheated 2 |
| 1.3.6.1.4.1.53332.1.3.29 | Scalarf2HallSenAl_1 | read-only | current | Hall sensor error 2 |
| 1.3.6.1.4.1.53332.1.3.30 | Scalarf2OverlAl_1 | read-only | current | Locked motor 2 |
| 1.3.6.1.4.1.53332.1.3.31 | Scalarf2LowDCAl_1 | read-only | current | Low DC 2 |
| 1.3.6.1.4.1.53332.1.3.32 | Scalarf3GeneralAl_1 | read-only | current | Fan general alarm 3 |
| 1.3.6.1.4.1.53332.1.3.33 | Scalarf3PowerAl_1 | read-only | current | Phase failure/undervolt.3 |
| 1.3.6.1.4.1.53332.1.3.34 | Scalarf3CommAl_1 | read-only | current | Communication 3 |
| 1.3.6.1.4.1.53332.1.3.35 | Scalarf3HiTempAl_1 | read-only | current | Power mod overheated 3 |
| 1.3.6.1.4.1.53332.1.3.36 | Scalarf3NetComAl_1 | read-only | current | Master/Slave com. 3 |
| 1.3.6.1.4.1.53332.1.3.37 | Scalarf3InvRegAl_1 | read-only | current | Regulation module 3 |
| 1.3.6.1.4.1.53332.1.3.38 | Scalarf3HiMotTAl_1 | read-only | current | Motor overheated 3 |
| 1.3.6.1.4.1.53332.1.3.39 | Scalarf3HallSenAl_1 | read-only | current | Hall sensor error 3 |
| 1.3.6.1.4.1.53332.1.3.40 | Scalarf3OverlAl_1 | read-only | current | Locked motor 3 |
| 1.3.6.1.4.1.53332.1.3.41 | Scalarf3LowDCAl_1 | read-only | current | Low DC 3 |
| 1.3.6.1.4.1.53332.1.3.42 | Scalarf4GeneralAl_1 | read-only | current | Fan general alarm 4 |
| 1.3.6.1.4.1.53332.1.3.43 | Scalarf4PowerAl_1 | read-only | current | Phase failure/undervolt.4 |
| 1.3.6.1.4.1.53332.1.3.44 | Scalarf4CommAl_1 | read-only | current | Communication 4 |
| 1.3.6.1.4.1.53332.1.3.45 | Scalarf4HiTempAl_1 | read-only | current | Power mod overheated 4 |
| 1.3.6.1.4.1.53332.1.3.46 | Scalarf4NetComAl_1 | read-only | current | Master/Slave com. 4 |
| 1.3.6.1.4.1.53332.1.3.47 | Scalarf4InvRegAl_1 | read-only | current | Regulation module 4 |
| 1.3.6.1.4.1.53332.1.3.48 | Scalarf4HiMotTAl_1 | read-only | current | Motor overheated 4 |
| 1.3.6.1.4.1.53332.1.3.49 | Scalarf4HallSenAl_1 | read-only | current | Hall sensor error 4 |
| 1.3.6.1.4.1.53332.1.3.50 | Scalarf4OverlAl_1 | read-only | current | Locked motor 4 |
| 1.3.6.1.4.1.53332.1.3.51 | Scalarf4LowDCAl_1 | read-only | current | Low DC 4 |
| 1.3.6.1.4.1.53332.1.3.52 | Scalarf5GeneralAl_1 | read-only | current | Fan general alarm 5 |
| 1.3.6.1.4.1.53332.1.3.53 | Scalarf5PowerAl_1 | read-only | current | Phase failure/undervolt.5 |
| 1.3.6.1.4.1.53332.1.3.54 | Scalarf5CommAl_1 | read-only | current | Communication 5 |
| 1.3.6.1.4.1.53332.1.3.55 | Scalarf5HiTempAl_1 | read-only | current | Power mod overheated 5 |
| 1.3.6.1.4.1.53332.1.3.56 | Scalarf5NetComAl_1 | read-only | current | Master/Slave com. 5 |
| 1.3.6.1.4.1.53332.1.3.57 | Scalarf5InvRegAl_1 | read-only | current | Regulation module 5 |
| 1.3.6.1.4.1.53332.1.3.58 | Scalarf5HiMotTAl_1 | read-only | current | Motor overheated 5 |
| 1.3.6.1.4.1.53332.1.3.59 | Scalarf5HallSenAl_1 | read-only | current | Hall sensor error 5 |
| 1.3.6.1.4.1.53332.1.3.60 | Scalarf5OverlAl_1 | read-only | current | Locked motor 5 |
| 1.3.6.1.4.1.53332.1.3.61 | Scalarf5LowDCAl_1 | read-only | current | Low DC 5 |
| 1.3.6.1.4.1.53332.1.3.62 | Scalarf6GeneralAl_1 | read-only | current | Fan general alarm 6 |
| 1.3.6.1.4.1.53332.1.3.63 | Scalarf6PowerAl_1 | read-only | current | Phase failure/undervolt.6 |
| 1.3.6.1.4.1.53332.1.3.64 | Scalarf6CommAl_1 | read-only | current | Communication 6 |
| 1.3.6.1.4.1.53332.1.3.65 | Scalarf6HiTempAl_1 | read-only | current | Power mod overheated 6 |
| 1.3.6.1.4.1.53332.1.3.66 | Scalarf6NetComAl_1 | read-only | current | Master/Slave com. 6 |
| 1.3.6.1.4.1.53332.1.3.67 | Scalarf6InvRegAl_1 | read-only | current | Regulation module 6 |
| 1.3.6.1.4.1.53332.1.3.68 | Scalarf6HiMotTAl_1 | read-only | current | Motor overheated 6 |
| 1.3.6.1.4.1.53332.1.3.69 | Scalarf6HallSenAl_1 | read-only | current | Hall sensor error 6 |
| 1.3.6.1.4.1.53332.1.3.70 | Scalarf6OverlAl_1 | read-only | current | Locked motor 6 |
| 1.3.6.1.4.1.53332.1.3.71 | Scalarf6LowDCAl_1 | read-only | current | Low DC 6 |
| 1.3.6.1.4.1.53332.1.3.72 | Scalarf7GeneralAl_1 | read-only | current | Fan general alarm 7 |
| 1.3.6.1.4.1.53332.1.3.73 | Scalarf7PowerAl_1 | read-only | current | Phase failure/undervolt.7 |
| 1.3.6.1.4.1.53332.1.3.74 | Scalarf7CommAl_1 | read-only | current | Communication 7 |
| 1.3.6.1.4.1.53332.1.3.75 | Scalarf7HiTempAl_1 | read-only | current | Power mod overheated 7 |
| 1.3.6.1.4.1.53332.1.3.76 | Scalarf7NetComAl_1 | read-only | current | Master/Slave com. 7 |
| 1.3.6.1.4.1.53332.1.3.77 | Scalarf7InvRegAl_1 | read-only | current | Regulation module 7 |
| 1.3.6.1.4.1.53332.1.3.78 | Scalarf7HiMotTAl_1 | read-only | current | Motor overheated 7 |
| 1.3.6.1.4.1.53332.1.3.79 | Scalarf7HallSenAl_1 | read-only | current | Hall sensor error 7 |
| 1.3.6.1.4.1.53332.1.3.80 | Scalarf7OverlAl_1 | read-only | current | Locked motor 7 |
| 1.3.6.1.4.1.53332.1.3.81 | Scalarf7LowDCAl_1 | read-only | current | Low DC 7 |
| 1.3.6.1.4.1.53332.1.3.82 | Scalarf8GeneralAl_1 | read-only | current | Fan general alarm 8 |
| 1.3.6.1.4.1.53332.1.3.83 | Scalarf8PowerAl_1 | read-only | current | Phase failure/undervolt.8 |
| 1.3.6.1.4.1.53332.1.3.84 | Scalarf8CommAl_1 | read-only | current | Communication 8 |
| 1.3.6.1.4.1.53332.1.3.85 | Scalarf8HiTempAl_1 | read-only | current | Power mod overheated 8 |
| 1.3.6.1.4.1.53332.1.3.86 | Scalarf8NetComAl_1 | read-only | current | Master/Slave com. 8 |
| 1.3.6.1.4.1.53332.1.3.87 | Scalarf8InvRegAl_1 | read-only | current | Regulation module 8 |
| 1.3.6.1.4.1.53332.1.3.88 | Scalarf8HiMotTAl_1 | read-only | current | Motor overheated 8 |
| 1.3.6.1.4.1.53332.1.3.89 | Scalarf8HallSenAl_1 | read-only | current | Hall sensor error 8 |
| 1.3.6.1.4.1.53332.1.3.90 | Scalarf8OverlAl_1 | read-only | current | Locked motor 8 |
| 1.3.6.1.4.1.53332.1.3.91 | Scalarf8LowDCAl_1 | read-only | current | Low DC 8 |
| 1.3.6.1.4.1.53332.1.3.92 | Scalarf9GeneralAl_1 | read-only | current | Fan general alarm 9 |
| 1.3.6.1.4.1.53332.1.3.93 | Scalarf9PowerAl_1 | read-only | current | Phase failure/undervolt.9 |
| 1.3.6.1.4.1.53332.1.3.94 | Scalarf9CommAl_1 | read-only | current | Communication 9 |
| 1.3.6.1.4.1.53332.1.3.95 | Scalarf9HiTempAl_1 | read-only | current | Power mod overheated 9 |
| 1.3.6.1.4.1.53332.1.3.96 | Scalarf9NetComAl_1 | read-only | current | Master/Slave com. 9 |
| 1.3.6.1.4.1.53332.1.3.97 | Scalarf9InvRegAl_1 | read-only | current | Regulation module 9 |
| 1.3.6.1.4.1.53332.1.3.98 | Scalarf9HiMotTAl_1 | read-only | current | Motor overheated 9 |
| 1.3.6.1.4.1.53332.1.3.99 | Scalarf9HallSenAl_1 | read-only | current | Hall sensor error 9 |
| 1.3.6.1.4.1.53332.1.3.100 | Scalarf9OverlAl_1 | read-only | current | Locked motor 9 |
| 1.3.6.1.4.1.53332.1.3.101 | Scalarf9LowDCAl_1 | read-only | current | Low DC 9 |
| 1.3.6.1.4.1.53332.1.3.102 | Scalarf10GenlAl_1 | read-only | current | Fan general alarm 10 |
| 1.3.6.1.4.1.53332.1.3.103 | Scalarf10PowerAl_1 | read-only | current | Phase failure/undervolt.10 |
| 1.3.6.1.4.1.53332.1.3.104 | Scalarf10CommAl_1 | read-only | current | Communication 10 |
| 1.3.6.1.4.1.53332.1.3.105 | Scalarf10HiTempAl_1 | read-only | current | Power mod overheated 10 |
| 1.3.6.1.4.1.53332.1.3.106 | Scalarf10NetComAl_1 | read-only | current | Master/Slave com. 10 |
| 1.3.6.1.4.1.53332.1.3.107 | Scalarf10InvRegAl_1 | read-only | current | Regulation module 10 |
| 1.3.6.1.4.1.53332.1.3.108 | Scalarf10HiMotTAl_1 | read-only | current | Motor overheated 10 |
| 1.3.6.1.4.1.53332.1.3.109 | Scalarf10HallSAl_1 | read-only | current | Hall sensor error 10 |
| 1.3.6.1.4.1.53332.1.3.110 | Scalarf10OverlAl_1 | read-only | current | Locked motor 10 |
| 1.3.6.1.4.1.53332.1.3.111 | Scalarf10LowDCAl_1 | read-only | current | Low DC 10 |
| 1.3.6.1.4.1.53332.1.3.112 | ScalarretTempPbAl_1 | read-only | current | Return temperature probe |
| 1.3.6.1.4.1.53332.1.3.113 | ScalarsupTempPrAl_1 | read-only | current | Supply temperature probe |
| 1.3.6.1.4.1.53332.1.3.114 | ScalarretHumPrAl_1 | read-only | current | Return humidity probe |
| 1.3.6.1.4.1.53332.1.3.115 | ScalarsupHumPrAl_1 | read-only | current | Supply humidity probe |
| 1.3.6.1.4.1.53332.1.3.116 | ScalarairPrSensAl_1 | read-only | current | Air diff.pressure probe |
| 1.3.6.1.4.1.53332.1.3.117 | ScalarwatIN1PrAl_1 | read-only | current | Water temp. IN1 probe |
| 1.3.6.1.4.1.53332.1.3.118 | ScalarwatOUT1PrAl_1 | read-only | current | Water temp. OUT1 probe |
| 1.3.6.1.4.1.53332.1.3.119 | ScalarwatIN2PrAl_1 | read-only | current | Water temp. IN2 probe |
| 1.3.6.1.4.1.53332.1.3.120 | ScalarwatOUT2PrAl_1 | read-only | current | Water temp. OUT2 probe |
| 1.3.6.1.4.1.53332.1.3.121 | ScalarwatFlw1PrAl_1 | read-only | current | Water flow1/T.liquid1 pr. |
| 1.3.6.1.4.1.53332.1.3.122 | ScalarwatFlw2PrAl_1 | read-only | current | Water flow2/T.liquid2 pr. |
| 1.3.6.1.4.1.53332.1.3.123 | ScalardFPSGenAl_1 | read-only | current | Filter diff.press. probe |
| 1.3.6.1.4.1.53332.1.3.124 | ScalardFPSBrokAl_1 | read-only | current | Breakdown alarm |
| 1.3.6.1.4.1.53332.1.3.125 | ScalardFPSCablAl_1 | read-only | current | Wiring alarm |
| 1.3.6.1.4.1.53332.1.3.126 | ScalardFPSRangeAl_1 | read-only | current | Pressure range alarm |
| 1.3.6.1.4.1.53332.1.3.127 | ScalardFPSADCAl_1 | read-only | current | ADC overload alarm |
| 1.3.6.1.4.1.53332.1.3.128 | ScalardFPSSetAl_1 | read-only | current | Calibration alarm |
| 1.3.6.1.4.1.53332.1.3.129 | ScalardFPSDCOAl_1 | read-only | current | DCO alarm |
| 1.3.6.1.4.1.53332.1.3.130 | ScalardFPSWatdAl_1 | read-only | current | Watchdog alarm |
| 1.3.6.1.4.1.53332.1.3.131 | ScalardFPSCommAl_1 | read-only | current | Communication alarm |
| 1.3.6.1.4.1.53332.1.3.132 | ScalarinvC1GenAl_1 | read-only | current | DC inverter general alarm |
| 1.3.6.1.4.1.53332.1.3.133 | ScalarinvC1CommAl_1 | read-only | current | Inverter communication |
| 1.3.6.1.4.1.53332.1.3.134 | Scalarc1ThermAl_1 | read-only | current | C1 Thermal alarm |
| 1.3.6.1.4.1.53332.1.3.135 | Scalarc1HighPresAl_1 | read-only | current | C1 High pressure alarm |
| 1.3.6.1.4.1.53332.1.3.136 | Scalarc1LowPresAl_1 | read-only | current | C1 Low pressure alarm |
| 1.3.6.1.4.1.53332.1.3.137 | Scalarc1HighDiscAl_1 | read-only | current | C1 High discharge alarm |
| 1.3.6.1.4.1.53332.1.3.138 | Scalarc1LCompRatAl_1 | read-only | current | C1 low compresion alarm |
| 1.3.6.1.4.1.53332.1.3.139 | Scalarcondenser1Al_1 | read-only | current | Condenser 1 general alarm |
| 1.3.6.1.4.1.53332.1.3.140 | Scalarc1WatFlowAl_1 | read-only | current | Condenser 1 flow alarm |
| 1.3.6.1.4.1.53332.1.3.141 | ScalareEV1GenAl_1 | read-only | current | EEV1 general alarm |
| 1.3.6.1.4.1.53332.1.3.142 | ScalareEV1CommAl_1 | read-only | current | EEV1 communication alarm |
| 1.3.6.1.4.1.53332.1.3.143 | ScalareEV1SuctPrAl_1 | read-only | current | EEV1 suction temp. probe |
| 1.3.6.1.4.1.53332.1.3.144 | ScalareEV1EvapPrAl_1 | read-only | current | EEV1 evap. temp. probe |
| 1.3.6.1.4.1.53332.1.3.145 | ScalareEV1CondPrAl_1 | read-only | current | EEV1 condens. temp. probe |
| 1.3.6.1.4.1.53332.1.3.146 | ScalareEV1DiscPrAl_1 | read-only | current | EEV1 disch. temp. probe |
| 1.3.6.1.4.1.53332.1.3.147 | Scalarc2ThermAl_1 | read-only | current | C2 Thermal alarm |
| 1.3.6.1.4.1.53332.1.3.148 | Scalarc2HighPresAl_1 | read-only | current | C2 High pressure alarm |
| 1.3.6.1.4.1.53332.1.3.149 | Scalarc2LowPresAl_1 | read-only | current | C2 Low pressure alarm |
| 1.3.6.1.4.1.53332.1.3.150 | Scalarc2HighDiscAl_1 | read-only | current | C2 High discharge alarm |
| 1.3.6.1.4.1.53332.1.3.151 | Scalarc2LCompRatAl_1 | read-only | current | C2 low compresion alarm |
| 1.3.6.1.4.1.53332.1.3.152 | Scalarcondenser2Al_1 | read-only | current | Condenser 2 general alarm |
| 1.3.6.1.4.1.53332.1.3.153 | Scalarc2WatFlowAl_1 | read-only | current | Condenser 2 flow alarm |
| 1.3.6.1.4.1.53332.1.3.154 | ScalareEV2GenAl_1 | read-only | current | EEV2 general alarm |
| 1.3.6.1.4.1.53332.1.3.155 | ScalareEV2CommAl_1 | read-only | current | EEV2 communication alarm |
| 1.3.6.1.4.1.53332.1.3.156 | ScalareEV2SuctPrAl_1 | read-only | current | EEV2 suction temp. probe |
| 1.3.6.1.4.1.53332.1.3.157 | ScalareEV2EvapPrAl_1 | read-only | current | EEV2 evap. temp. probe |
| 1.3.6.1.4.1.53332.1.3.158 | ScalareEV2CondPrAl_1 | read-only | current | EEV2 condens. temp. probe |
| 1.3.6.1.4.1.53332.1.3.159 | ScalareEV2DiscPrAl_1 | read-only | current | EEV2 disch. temp. probe |
| 1.3.6.1.4.1.53332.1.3.160 | ScalarintHumGenAl_1 | read-only | current | Internal humidifier alarm |
| 1.3.6.1.4.1.53332.1.3.161 | ScalarcPYCommAl_1 | read-only | current | Communication alarm |
| 1.3.6.1.4.1.53332.1.3.162 | ScalarcPYMemoryAl_1 | read-only | current | Memory error alarm |
| 1.3.6.1.4.1.53332.1.3.163 | ScalarcPYParamAl_1 | read-only | current | Parameters error alarm |
| 1.3.6.1.4.1.53332.1.3.164 | ScalarcPYHighCurAl_1 | read-only | current | Electrodes high current |
| 1.3.6.1.4.1.53332.1.3.165 | ScalarcPYLoSteamAl_1 | read-only | current | Low steam product. alarm |
| 1.3.6.1.4.1.53332.1.3.166 | ScalarcPYDrainAl_1 | read-only | current | Drain loss alarm |
| 1.3.6.1.4.1.53332.1.3.167 | ScalarcPYMaintAl_1 | read-only | current | Maintenance hours alarm |
| 1.3.6.1.4.1.53332.1.3.168 | ScalarcPYNoWaterAl_1 | read-only | current | Water loss alarm |
| 1.3.6.1.4.1.53332.1.3.169 | ScalarcPYCylMainAl_1 | read-only | current | Cylinder mainten. alarm |
| 1.3.6.1.4.1.53332.1.3.170 | ScalarcPYDirtCylAl_1 | read-only | current | Exaust cylinder alarm |
| 1.3.6.1.4.1.53332.1.3.171 | ScalarcPYFoamAl_1 | read-only | current | Foam presence alarm |
| 1.3.6.1.4.1.53332.1.3.172 | ScalarcPYLifeTimAl_1 | read-only | current | Life time expired alarm |
| 1.3.6.1.4.1.53332.1.3.173 | ScalarcPYHiWLevAl_1 | read-only | current | High water level alarm |
| 1.3.6.1.4.1.53332.1.3.174 | ScalarcPYHWatConAl_1 | read-only | current | High conductivity alarm |
| 1.3.6.1.4.1.53332.1.3.175 | ScalarcPYConnAl_1 | read-only | current | Connection error alarm |
| 1.3.6.1.4.1.53332.1.3.176 | ScalarwatPresAl_1 | read-only | current | Water presence alarm |
| 1.3.6.1.4.1.53332.1.3.177 | ScalardrainPumpAl_1 | read-only | current | Drain pump alarm |
| 1.3.6.1.4.1.53332.1.3.178 | ScalarelHeatAl_1 | read-only | current | Electric heater alarm |
| 1.3.6.1.4.1.53332.1.3.179 | ScalarfilterAl_1 | read-only | current | Dirty filter alarm |
| 1.3.6.1.4.1.53332.1.3.180 | ScalardryCoolerAl_1 | read-only | current | Dry cooler alarm |
| 1.3.6.1.4.1.53332.1.3.181 | ScalarextHumidAl_1 | read-only | current | External humidifier alarm |
| 1.3.6.1.4.1.53332.1.3.182 | ScalarwaterPumpAl_1 | read-only | current | Water pump alarm |
| 1.3.6.1.4.1.53332.1.3.183 | ScalarcondUnitGAl_1 | read-only | current | Motocondenser alarm |
| 1.3.6.1.4.1.53332.1.3.184 | ScalargasLeakAl_1 | read-only | current | Refrigerant leak alarm |
| 1.3.6.1.4.1.53332.1.3.185 | ScalarpowerSuppAl_1 | read-only | current | Power fault alarm |
| 1.3.6.1.4.1.53332.1.3.186 | ScalargenSoftAl_1 | read-only | current | Not critical generic al. |
| 1.3.6.1.4.1.53332.1.3.187 | ScalarlocalNetAl_1 | read-only | current | Local network alarm |
| 1.3.6.1.4.1.53332.1.3.188 | ScalarregHiTempAl_1 | read-only | current | High regulation T.alarm |
| 1.3.6.1.4.1.53332.1.3.189 | ScalarregLowTempAl_1 | read-only | current | Low regulation T.alarm |
| 1.3.6.1.4.1.53332.1.3.190 | ScalarhiLimTempAl_1 | read-only | current | High limit temp. alarm |
| 1.3.6.1.4.1.53332.1.3.191 | ScalarlowLimTempAl_1 | read-only | current | Low limit temp. alarm |
| 1.3.6.1.4.1.53332.1.3.192 | ScalarretHiHumiAl_1 | read-only | current | High room humidity alarm |
| 1.3.6.1.4.1.53332.1.3.193 | ScalarretLowHumiAl_1 | read-only | current | Low room humidity alarm |
| 1.3.6.1.4.1.53332.1.3.194 | ScalarsupHiHumiAl_1 | read-only | current | High supp.humidity alarm |
| 1.3.6.1.4.1.53332.1.3.195 | ScalarsupLowHumiAl_1 | read-only | current | Low supp.humidity alarm |
| 1.3.6.1.4.1.53332.1.3.196 | ScalarprobeMod1COM_1 | read-only | current | Module 1 communication |
| 1.3.6.1.4.1.53332.1.3.197 | ScalarprMod1err1_1 | read-only | current | Module 1 probe 1 alarm |
| 1.3.6.1.4.1.53332.1.3.198 | ScalarprMod1err2_1 | read-only | current | Module 1 probe 2 alarm |
| 1.3.6.1.4.1.53332.1.3.199 | ScalarprMod1err3_1 | read-only | current | Module 1 probe 3 alarm |
| 1.3.6.1.4.1.53332.1.3.200 | ScalarprMod1err4_1 | read-only | current | Module 1 probe 4 alarm |
| 1.3.6.1.4.1.53332.1.3.201 | ScalarprMod1err5_1 | read-only | current | Module 1 probe 5 alarm |
| 1.3.6.1.4.1.53332.1.3.202 | ScalarprMod1err6_1 | read-only | current | Module 1 probe 6 alarm |
| 1.3.6.1.4.1.53332.1.3.203 | ScalarprobeMod2COM_1 | read-only | current | Module 2 communication |
| 1.3.6.1.4.1.53332.1.3.204 | ScalarprMod2err1_1 | read-only | current | Module 2 probe 1 alarm |
| 1.3.6.1.4.1.53332.1.3.205 | ScalarprMod2err2_1 | read-only | current | Module 2 probe 2 alarm |
| 1.3.6.1.4.1.53332.1.3.206 | ScalarprMod2err3_1 | read-only | current | Module 2 probe 3 alarm |
| 1.3.6.1.4.1.53332.1.3.207 | ScalarprMod2err4_1 | read-only | current | Module 2 probe 4 alarm |
| 1.3.6.1.4.1.53332.1.3.208 | ScalarprMod2err5_1 | read-only | current | Module 2 probe 5 alarm |
| 1.3.6.1.4.1.53332.1.3.209 | ScalarprMod2err6_1 | read-only | current | Module 2 probe 6 alarm |
| 1.3.6.1.4.1.53332.1.3.210 | ScalarprobeMod3COM_1 | read-only | current | Module 3 communication |
| 1.3.6.1.4.1.53332.1.3.211 | ScalarprMod3err1_1 | read-only | current | Module 3 probe 1 alarm |
| 1.3.6.1.4.1.53332.1.3.212 | ScalarprMod3err2_1 | read-only | current | Module 3 probe 2 alarm |
| 1.3.6.1.4.1.53332.1.3.213 | ScalarprMod3err3_1 | read-only | current | Module 3 probe 3 alarm |
| 1.3.6.1.4.1.53332.1.3.214 | ScalarprMod3err4_1 | read-only | current | Module 3 probe 4 alarm |
| 1.3.6.1.4.1.53332.1.3.215 | ScalarprMod3err5_1 | read-only | current | Module 3 probe 5 alarm |
| 1.3.6.1.4.1.53332.1.3.216 | ScalarprMod3err6_1 | read-only | current | Module 3 probe 6 alarm |
| 1.3.6.1.4.1.53332.2 | Nodenode2 | |||
| 1.3.6.1.4.1.53332.2.0 | Nodetraps2 | |||
| 1.3.6.1.4.1.53332.2.0.1 | NotificationgeneralAlTrap_2 | current | General alarams | |
| 1.3.6.1.4.1.53332.2.0.2 | NotificationnotCriticalAlTrap_2 | current | Not critical alarms | |
| 1.3.6.1.4.1.53332.2.0.3 | NotificationcriticalAlTrap_2 | current | Critical alarms | |
| 1.3.6.1.4.1.53332.2.0.4 | NotificationfansAlTrap_2 | current | Fans alarms | |
| 1.3.6.1.4.1.53332.2.0.5 | NotificationcompAlTrap_2 | current | Compressors alarms | |
| 1.3.6.1.4.1.53332.2.0.6 | NotificationtemperatureAlTrap_2 | current | Temperature alarms | |
| 1.3.6.1.4.1.53332.2.0.7 | NotificationhumidityAlTrap_2 | current | Humidity alarms | |
| 1.3.6.1.4.1.53332.2.0.8 | NotificationdamperAlTrap_2 | current | Damper status alarm | |
| 1.3.6.1.4.1.53332.2.0.9 | NotificationfireSmokeAlTrap_2 | current | Fire/Smoke alarm | |
| 1.3.6.1.4.1.53332.2.0.10 | NotificationgenSeriousAlTrap_2 | current | Critical generic alarm | |
| 1.3.6.1.4.1.53332.2.0.11 | NotificationfansGenAlTrap_2 | current | General supply fans alarm | |
| 1.3.6.1.4.1.53332.2.0.12 | Notificationf1GeneralAlTrap_2 | current | Fan general alarm 1 | |
| 1.3.6.1.4.1.53332.2.0.13 | Notificationf1PowerAlTrap_2 | current | Phase failure/undervolt.1 | |
| 1.3.6.1.4.1.53332.2.0.14 | Notificationf1CommAlTrap_2 | current | Communication 1 | |
| 1.3.6.1.4.1.53332.2.0.15 | Notificationf1HighTempAlTrap_2 | current | Power mod overheated 1 | |
| 1.3.6.1.4.1.53332.2.0.16 | Notificationf1NetComAlTrap_2 | current | Master/Slave com. 1 | |
| 1.3.6.1.4.1.53332.2.0.17 | Notificationf1InvRegAlTrap_2 | current | Regulation module 1 | |
| 1.3.6.1.4.1.53332.2.0.18 | Notificationf1HighMotTempAlTrap_2 | current | Motor overheated 1 | |
| 1.3.6.1.4.1.53332.2.0.19 | Notificationf1HallSensAlTrap_2 | current | Hall sensor error 1 | |
| 1.3.6.1.4.1.53332.2.0.20 | Notificationf1OverloadAlTrap_2 | current | Locked motor 1 | |
| 1.3.6.1.4.1.53332.2.0.21 | Notificationf1LowDCAlTrap_2 | current | Low DC 1 | |
| 1.3.6.1.4.1.53332.2.0.22 | Notificationf2GeneralAlTrap_2 | current | Fan general alarm 2 | |
| 1.3.6.1.4.1.53332.2.0.23 | Notificationf2PowerAlTrap_2 | current | Phase failure/undervolt.2 | |
| 1.3.6.1.4.1.53332.2.0.24 | Notificationf2CommAlTrap_2 | current | Communication 2 | |
| 1.3.6.1.4.1.53332.2.0.25 | Notificationf2HighTempAlTrap_2 | current | Power mod overheated 2 | |
| 1.3.6.1.4.1.53332.2.0.26 | Notificationf2NetComAlTrap_2 | current | Master/Slave com. 2 | |
| 1.3.6.1.4.1.53332.2.0.27 | Notificationf2InvRegAlTrap_2 | current | Regulation module 2 | |
| 1.3.6.1.4.1.53332.2.0.28 | Notificationf2HighMotTempAlTrap_2 | current | Motor overheated 2 | |
| 1.3.6.1.4.1.53332.2.0.29 | Notificationf2HallSensAlTrap_2 | current | Hall sensor error 2 | |
| 1.3.6.1.4.1.53332.2.0.30 | Notificationf2OverloadAlTrap_2 | current | Locked motor 2 | |
| 1.3.6.1.4.1.53332.2.0.31 | Notificationf2LowDCAlTrap_2 | current | Low DC 2 | |
| 1.3.6.1.4.1.53332.2.0.32 | Notificationf3GeneralAlTrap_2 | current | Fan general alarm 3 | |
| 1.3.6.1.4.1.53332.2.0.33 | Notificationf3PowerAlTrap_2 | current | Phase failure/undervolt.3 | |
| 1.3.6.1.4.1.53332.2.0.34 | Notificationf3CommAlTrap_2 | current | Communication 3 | |
| 1.3.6.1.4.1.53332.2.0.35 | Notificationf3HighTempAlTrap_2 | current | Power mod overheated 3 | |
| 1.3.6.1.4.1.53332.2.0.36 | Notificationf3NetComAlTrap_2 | current | Master/Slave com. 3 | |
| 1.3.6.1.4.1.53332.2.0.37 | Notificationf3InvRegAlTrap_2 | current | Regulation module 3 | |
| 1.3.6.1.4.1.53332.2.0.38 | Notificationf3HighMotTempAlTrap_2 | current | Motor overheated 3 | |
| 1.3.6.1.4.1.53332.2.0.39 | Notificationf3HallSensAlTrap_2 | current | Hall sensor error 3 | |
| 1.3.6.1.4.1.53332.2.0.40 | Notificationf3OverloadAlTrap_2 | current | Locked motor 3 | |
| 1.3.6.1.4.1.53332.2.0.41 | Notificationf3LowDCAlTrap_2 | current | Low DC 3 | |
| 1.3.6.1.4.1.53332.2.0.42 | Notificationf4GeneralAlTrap_2 | current | Fan general alarm 4 | |
| 1.3.6.1.4.1.53332.2.0.43 | Notificationf4PowerAlTrap_2 | current | Phase failure/undervolt.4 | |
| 1.3.6.1.4.1.53332.2.0.44 | Notificationf4CommAlTrap_2 | current | Communication 4 | |
| 1.3.6.1.4.1.53332.2.0.45 | Notificationf4HighTempAlTrap_2 | current | Power mod overheated 4 | |
| 1.3.6.1.4.1.53332.2.0.46 | Notificationf4NetComAlTrap_2 | current | Master/Slave com. 4 | |
| 1.3.6.1.4.1.53332.2.0.47 | Notificationf4InvRegAlTrap_2 | current | Regulation module 4 | |
| 1.3.6.1.4.1.53332.2.0.48 | Notificationf4HighMotTempAlTrap_2 | current | Motor overheated 4 | |
| 1.3.6.1.4.1.53332.2.0.49 | Notificationf4HallSensAlTrap_2 | current | Hall sensor error 4 | |
| 1.3.6.1.4.1.53332.2.0.50 | Notificationf4OverloadAlTrap_2 | current | Locked motor 4 | |
| 1.3.6.1.4.1.53332.2.0.51 | Notificationf4LowDCAlTrap_2 | current | Low DC 4 | |
| 1.3.6.1.4.1.53332.2.0.52 | Notificationf5GeneralAlTrap_2 | current | Fan general alarm 5 | |
| 1.3.6.1.4.1.53332.2.0.53 | Notificationf5PowerAlTrap_2 | current | Phase failure/undervolt.5 | |
| 1.3.6.1.4.1.53332.2.0.54 | Notificationf5CommAlTrap_2 | current | Communication 5 | |
| 1.3.6.1.4.1.53332.2.0.55 | Notificationf5HighTempAlTrap_2 | current | Power mod overheated 5 | |
| 1.3.6.1.4.1.53332.2.0.56 | Notificationf5NetComAlTrap_2 | current | Master/Slave com. 5 | |
| 1.3.6.1.4.1.53332.2.0.57 | Notificationf5InvRegAlTrap_2 | current | Regulation module 5 | |
| 1.3.6.1.4.1.53332.2.0.58 | Notificationf5HighMotTempAlTrap_2 | current | Motor overheated 5 | |
| 1.3.6.1.4.1.53332.2.0.59 | Notificationf5HallSensAlTrap_2 | current | Hall sensor error 5 | |
| 1.3.6.1.4.1.53332.2.0.60 | Notificationf5OverloadAlTrap_2 | current | Locked motor 5 | |
| 1.3.6.1.4.1.53332.2.0.61 | Notificationf5LowDCAlTrap_2 | current | Low DC 5 | |
| 1.3.6.1.4.1.53332.2.0.62 | Notificationf6GeneralAlTrap_2 | current | Fan general alarm 6 | |
| 1.3.6.1.4.1.53332.2.0.63 | Notificationf6PowerAlTrap_2 | current | Phase failure/undervolt.6 | |
| 1.3.6.1.4.1.53332.2.0.64 | Notificationf6CommAlTrap_2 | current | Communication 6 | |
| 1.3.6.1.4.1.53332.2.0.65 | Notificationf6HighTempAlTrap_2 | current | Power mod overheated 6 | |
| 1.3.6.1.4.1.53332.2.0.66 | Notificationf6NetComAlTrap_2 | current | Master/Slave com. 6 | |
| 1.3.6.1.4.1.53332.2.0.67 | Notificationf6InvRegAlTrap_2 | current | Regulation module 6 | |
| 1.3.6.1.4.1.53332.2.0.68 | Notificationf6HighMotTempAlTrap_2 | current | Motor overheated 6 | |
| 1.3.6.1.4.1.53332.2.0.69 | Notificationf6HallSensAlTrap_2 | current | Hall sensor error 6 | |
| 1.3.6.1.4.1.53332.2.0.70 | Notificationf6OverloadAlTrap_2 | current | Locked motor 6 | |
| 1.3.6.1.4.1.53332.2.0.71 | Notificationf6LowDCAlTrap_2 | current | Low DC 6 | |
| 1.3.6.1.4.1.53332.2.0.72 | Notificationf7GeneralAlTrap_2 | current | Fan general alarm 7 | |
| 1.3.6.1.4.1.53332.2.0.73 | Notificationf7PowerAlTrap_2 | current | Phase failure/undervolt.7 | |
| 1.3.6.1.4.1.53332.2.0.74 | Notificationf7CommAlTrap_2 | current | Communication 7 | |
| 1.3.6.1.4.1.53332.2.0.75 | Notificationf7HighTempAlTrap_2 | current | Power mod overheated 7 | |
| 1.3.6.1.4.1.53332.2.0.76 | Notificationf7NetComAlTrap_2 | current | Master/Slave com. 7 | |
| 1.3.6.1.4.1.53332.2.0.77 | Notificationf7InvRegAlTrap_2 | current | Regulation module 7 | |
| 1.3.6.1.4.1.53332.2.0.78 | Notificationf7HighMotTempAlTrap_2 | current | Motor overheated 7 | |
| 1.3.6.1.4.1.53332.2.0.79 | Notificationf7HallSensAlTrap_2 | current | Hall sensor error 7 | |
| 1.3.6.1.4.1.53332.2.0.80 | Notificationf7OverloadAlTrap_2 | current | Locked motor 7 | |
| 1.3.6.1.4.1.53332.2.0.81 | Notificationf7LowDCAlTrap_2 | current | Low DC 7 | |
| 1.3.6.1.4.1.53332.2.0.82 | Notificationf8GeneralAlTrap_2 | current | Fan general alarm 8 | |
| 1.3.6.1.4.1.53332.2.0.83 | Notificationf8PowerAlTrap_2 | current | Phase failure/undervolt.8 | |
| 1.3.6.1.4.1.53332.2.0.84 | Notificationf8CommAlTrap_2 | current | Communication 8 | |
| 1.3.6.1.4.1.53332.2.0.85 | Notificationf8HighTempAlTrap_2 | current | Power mod overheated 8 | |
| 1.3.6.1.4.1.53332.2.0.86 | Notificationf8NetComAlTrap_2 | current | Master/Slave com. 8 | |
| 1.3.6.1.4.1.53332.2.0.87 | Notificationf8InvRegAlTrap_2 | current | Regulation module 8 | |
| 1.3.6.1.4.1.53332.2.0.88 | Notificationf8HighMotTempAlTrap_2 | current | Motor overheated 8 | |
| 1.3.6.1.4.1.53332.2.0.89 | Notificationf8HallSensAlTrap_2 | current | Hall sensor error 8 | |
| 1.3.6.1.4.1.53332.2.0.90 | Notificationf8OverloadAlTrap_2 | current | Locked motor 8 | |
| 1.3.6.1.4.1.53332.2.0.91 | Notificationf8LowDCAlTrap_2 | current | Low DC 8 | |
| 1.3.6.1.4.1.53332.2.0.92 | Notificationf9InverterAlTrap_2 | current | Fan general alarm 9 | |
| 1.3.6.1.4.1.53332.2.0.93 | Notificationf9PowerAlTrap_2 | current | Phase failure/undervolt.9 | |
| 1.3.6.1.4.1.53332.2.0.94 | Notificationf9CommAlTrap_2 | current | Communication 9 | |
| 1.3.6.1.4.1.53332.2.0.95 | Notificationf9HighTempAlTrap_2 | current | Power mod overheated 9 | |
| 1.3.6.1.4.1.53332.2.0.96 | Notificationf9NetComAlTrap_2 | current | Master/Slave com. 9 | |
| 1.3.6.1.4.1.53332.2.0.97 | Notificationf9InvRegAlTrap_2 | current | Regulation module 9 | |
| 1.3.6.1.4.1.53332.2.0.98 | Notificationf9HighMotTempAlTrap_2 | current | Motor overheated 9 | |
| 1.3.6.1.4.1.53332.2.0.99 | Notificationf9HallSensAlTrap_2 | current | Hall sensor error 9 | |
| 1.3.6.1.4.1.53332.2.0.100 | Notificationf9OverloadAlTrap_2 | current | Locked motor 9 | |
| 1.3.6.1.4.1.53332.2.0.101 | Notificationf9LowDCAlTrap_2 | current | Low DC 9 | |
| 1.3.6.1.4.1.53332.2.0.102 | Notificationf10GeneralAlTrap_2 | current | Fan general alarm 10 | |
| 1.3.6.1.4.1.53332.2.0.103 | Notificationf10PowerAlTrap_2 | current | Phase failure/undervolt.10 | |
| 1.3.6.1.4.1.53332.2.0.104 | Notificationf10CommAlTrap_2 | current | Communication 10 | |
| 1.3.6.1.4.1.53332.2.0.105 | Notificationf10HighTempAlTrap_2 | current | Power mod overheated 10 | |
| 1.3.6.1.4.1.53332.2.0.106 | Notificationf10NetComAlTrap_2 | current | Master/Slave com. 10 | |
| 1.3.6.1.4.1.53332.2.0.107 | Notificationf10InvRegAlTrap_2 | current | Regulation module 10 | |
| 1.3.6.1.4.1.53332.2.0.108 | Notificationf10HighMotTAlTrap_2 | current | Motor overheated 10 | |
| 1.3.6.1.4.1.53332.2.0.109 | Notificationf10HallSensAlTrap_2 | current | Hall sensor error 10 | |
| 1.3.6.1.4.1.53332.2.0.110 | Notificationf10OverloadAlTrap_2 | current | Locked motor 10 | |
| 1.3.6.1.4.1.53332.2.0.111 | Notificationf10LowDCAlTrap_2 | current | Low DC 10 | |
| 1.3.6.1.4.1.53332.2.0.112 | NotificationretTempProbAlTrap_2 | current | Return temperature probe | |
| 1.3.6.1.4.1.53332.2.0.113 | NotificationsupTempProbAlTrap_2 | current | Supply temperature probe | |
| 1.3.6.1.4.1.53332.2.0.114 | NotificationretHumProbAlTrap_2 | current | Return humidity probe | |
| 1.3.6.1.4.1.53332.2.0.115 | NotificationsupHumProbAlTrap_2 | current | Supply humidity probe | |
| 1.3.6.1.4.1.53332.2.0.116 | NotificationairPrSensorAlTrap_2 | current | Air diff.pressure probe | |
| 1.3.6.1.4.1.53332.2.0.117 | NotificationwatIN1ProbAlTrap_2 | current | Water temp. IN1 probe | |
| 1.3.6.1.4.1.53332.2.0.118 | NotificationwatOUT1ProbAlTrap_2 | current | Water temp. OUT1 probe | |
| 1.3.6.1.4.1.53332.2.0.119 | NotificationwatIN2ProbAlTrap_2 | current | Water temp. IN2 probe | |
| 1.3.6.1.4.1.53332.2.0.120 | NotificationwatOUT2ProbAlTrap_2 | current | Water temp. OUT2 probe | |
| 1.3.6.1.4.1.53332.2.0.121 | NotificationwatFlw1ProbAlTrap_2 | current | Water flow1/T.liquid1 pr. | |
| 1.3.6.1.4.1.53332.2.0.122 | NotificationwatFlw2ProbAlTrap_2 | current | Water flow2/T.liquid2 pr. | |
| 1.3.6.1.4.1.53332.2.0.123 | NotificationdFPSGenAlTrap_2 | current | Filter diff.press. probe | |
| 1.3.6.1.4.1.53332.2.0.124 | NotificationdFPSBrokenAlTrap_2 | current | Breakdown alarm | |
| 1.3.6.1.4.1.53332.2.0.125 | NotificationdFPSCablingAlTrap_2 | current | Wiring alarm | |
| 1.3.6.1.4.1.53332.2.0.126 | NotificationdFPSRangeAlTrap_2 | current | Pressure range alarm | |
| 1.3.6.1.4.1.53332.2.0.127 | NotificationdFPSADCAlTrap_2 | current | ADC overload alarm | |
| 1.3.6.1.4.1.53332.2.0.128 | NotificationdFPSSettingAlTrap_2 | current | Calibration alarm | |
| 1.3.6.1.4.1.53332.2.0.129 | NotificationdFPSDCOAlTrap_2 | current | DCO alarm | |
| 1.3.6.1.4.1.53332.2.0.130 | NotificationdFPSWatchdogAlTrap_2 | current | Watchdog alarm | |
| 1.3.6.1.4.1.53332.2.0.131 | NotificationdFPSCommAlTrap_2 | current | Communication alarm | |
| 1.3.6.1.4.1.53332.2.0.132 | NotificationinvCompGenAlTrap_2 | current | DC inverter general alarm | |
| 1.3.6.1.4.1.53332.2.0.133 | NotificationinvCompCommAlTrap_2 | current | Inverter communication | |
| 1.3.6.1.4.1.53332.2.0.134 | NotificationinvCompAlCode1Trap_2 | current | DC Inverter alarm code 1 | |
| 1.3.6.1.4.1.53332.2.0.135 | NotificationinvCompAlCode2Trap_2 | current | DC Inverter alarm code 2 | |
| 1.3.6.1.4.1.53332.2.0.136 | NotificationinvCompAlCode3Trap_2 | current | DC Inverter alarm code 3 | |
| 1.3.6.1.4.1.53332.2.0.137 | NotificationinvCompAlCode4Trap_2 | current | DC Inverter alarm code 4 | |
| 1.3.6.1.4.1.53332.2.0.138 | NotificationinvCompAlCode5Trap_2 | current | DC Inverter alarm code 5 | |
| 1.3.6.1.4.1.53332.2.0.139 | Notificationc1ThermAlTrap_2 | current | C1 Thermal alarm | |
| 1.3.6.1.4.1.53332.2.0.140 | Notificationc1HighPresAlTrap_2 | current | C1 High pressure alarm | |
| 1.3.6.1.4.1.53332.2.0.141 | Notificationc1LowPresAlTrap_2 | current | C1 Low pressure alarm | |
| 1.3.6.1.4.1.53332.2.0.142 | Notificationc1HighDischAlTrap_2 | current | C1 High discharge alarm | |
| 1.3.6.1.4.1.53332.2.0.143 | Notificationc1LCompRatAlTrap_2 | current | C1 low compresion alarm | |
| 1.3.6.1.4.1.53332.2.0.144 | Notificationcondenser1AlTrap_2 | current | Condenser 1 general alarm | |
| 1.3.6.1.4.1.53332.2.0.145 | Notificationc1WatFlowAlTrap_2 | current | Condenser 1 flow alarm | |
| 1.3.6.1.4.1.53332.2.0.146 | NotificationeEV1GenAlTrap_2 | current | EEV1 general alarm | |
| 1.3.6.1.4.1.53332.2.0.147 | NotificationeEV1CommAlTrap_2 | current | EEV1 communication alarm | |
| 1.3.6.1.4.1.53332.2.0.148 | NotificationeEV1SuctProbAlTrap_2 | current | EEV1 suction temp. probe | |
| 1.3.6.1.4.1.53332.2.0.149 | NotificationeEV1EvapProbAlTrap_2 | current | EEV1 evap. temp. probe | |
| 1.3.6.1.4.1.53332.2.0.150 | NotificationeEV1CondProbAlTrap_2 | current | EEV1 condens. temp. probe | |
| 1.3.6.1.4.1.53332.2.0.151 | NotificationeEV1DischProbAlTrap_2 | current | EEV1 disch. temp. probe | |
| 1.3.6.1.4.1.53332.2.0.152 | Notificationc2ThermAlTrap_2 | current | C2 Thermal alarm | |
| 1.3.6.1.4.1.53332.2.0.153 | Notificationc2HighPresAlTrap_2 | current | C2 High pressure alarm | |
| 1.3.6.1.4.1.53332.2.0.154 | Notificationc2LowPresAlTrap_2 | current | C2 Low pressure alarm | |
| 1.3.6.1.4.1.53332.2.0.155 | Notificationc2HighDischAlTrap_2 | current | C2 High discharge alarm | |
| 1.3.6.1.4.1.53332.2.0.156 | Notificationc2LCompRatAlTrap_2 | current | C2 low compresion alarm | |
| 1.3.6.1.4.1.53332.2.0.157 | Notificationcondenser2AlTrap_2 | current | Condenser 2 general alarm | |
| 1.3.6.1.4.1.53332.2.0.158 | Notificationc2WatFlowAlTrap_2 | current | Condenser 2 flow alarm | |
| 1.3.6.1.4.1.53332.2.0.159 | NotificationeEV2GenAlTrap_2 | current | EEV2 general alarm | |
| 1.3.6.1.4.1.53332.2.0.160 | NotificationeEV2CommAlTrap_2 | current | EEV2 communication alarm | |
| 1.3.6.1.4.1.53332.2.0.161 | NotificationeEV2SuctProbAlTrap_2 | current | EEV2 suction temp. probe | |
| 1.3.6.1.4.1.53332.2.0.162 | NotificationeEV2EvapProbAlTrap_2 | current | EEV2 evap. temp. probe | |
| 1.3.6.1.4.1.53332.2.0.163 | NotificationeEV2CondProbAlTrap_2 | current | EEV2 condens. temp. probe | |
| 1.3.6.1.4.1.53332.2.0.164 | NotificationeEV2DischProbAlTrap_2 | current | EEV2 disch. temp. probe | |
| 1.3.6.1.4.1.53332.2.0.165 | NotificationintHumidGenAlTrap_2 | current | Internal humidifier alarm | |
| 1.3.6.1.4.1.53332.2.0.166 | NotificationcPYCommAlTrap_2 | current | Communication alarm | |
| 1.3.6.1.4.1.53332.2.0.167 | NotificationcPYMemoryAlTrap_2 | current | Memory error alarm | |
| 1.3.6.1.4.1.53332.2.0.168 | NotificationcPYParameterAlTrap_2 | current | Parameters error alarm | |
| 1.3.6.1.4.1.53332.2.0.169 | NotificationcPYHighCurrAlTrap_2 | current | Electrodes high current | |
| 1.3.6.1.4.1.53332.2.0.170 | NotificationcPYLowSteamAlTrap_2 | current | Low steam product. alarm | |
| 1.3.6.1.4.1.53332.2.0.171 | NotificationcPYDrainAlTrap_2 | current | Drain loss alarm | |
| 1.3.6.1.4.1.53332.2.0.172 | NotificationcPYMaintAlTrap_2 | current | Maintenance hours alarm | |
| 1.3.6.1.4.1.53332.2.0.173 | NotificationcPYNoWaterAlTrap_2 | current | Water loss alarm | |
| 1.3.6.1.4.1.53332.2.0.174 | NotificationcPYCylMaintAlTrap_2 | current | Cylinder mainten. alarm | |
| 1.3.6.1.4.1.53332.2.0.175 | NotificationcPYDirtyCylAlTrap_2 | current | Exaust cylinder alarm | |
| 1.3.6.1.4.1.53332.2.0.176 | NotificationcPYFoamAlTrap_2 | current | Foam presence alarm | |
| 1.3.6.1.4.1.53332.2.0.177 | NotificationcPYLifeTimeAlTrap_2 | current | Life time expired alarm | |
| 1.3.6.1.4.1.53332.2.0.178 | NotificationcPYHighWatLevAlTrap_2 | current | High water level alarm | |
| 1.3.6.1.4.1.53332.2.0.179 | NotificationcPYHWatCondAlTrap_2 | current | High conductivity alarm | |
| 1.3.6.1.4.1.53332.2.0.180 | NotificationcPYConnectionAlTrap_2 | current | Connection error alarm | |
| 1.3.6.1.4.1.53332.2.0.181 | NotificationwatPresAlTrap_2 | current | Water presence alarm | |
| 1.3.6.1.4.1.53332.2.0.182 | NotificationdrainPumpAlTrap_2 | current | Drain pump alarm | |
| 1.3.6.1.4.1.53332.2.0.183 | NotificationelHeatAlTrap_2 | current | Electric heater alarm | |
| 1.3.6.1.4.1.53332.2.0.184 | NotificationfilterAlTrap_2 | current | Dirty filter alarm | |
| 1.3.6.1.4.1.53332.2.0.185 | NotificationdryCoolerAlTrap_2 | current | Dry cooler alarm | |
| 1.3.6.1.4.1.53332.2.0.186 | NotificationextHumidAlTrap_2 | current | External humidifier alarm | |
| 1.3.6.1.4.1.53332.2.0.187 | NotificationwaterPumpAlTrap_2 | current | Water pump alarm | |
| 1.3.6.1.4.1.53332.2.0.188 | NotificationcondUnitGenAlTrap_2 | current | Motocondenser alarm | |
| 1.3.6.1.4.1.53332.2.0.189 | NotificationgasLeakAlTrap_2 | current | Refrigerant leak alarm | |
| 1.3.6.1.4.1.53332.2.0.190 | NotificationpowerSupplyAlTrap_2 | current | Power fault alarm | |
| 1.3.6.1.4.1.53332.2.0.191 | NotificationgenericSoftAlTrap_2 | current | Not critical generic al. | |
| 1.3.6.1.4.1.53332.2.0.192 | NotificationlocalNetworkAlTrap_2 | current | Local network alarm | |
| 1.3.6.1.4.1.53332.2.0.193 | NotificationregHighTempAlTrap_2 | current | High regulation T.alarm | |
| 1.3.6.1.4.1.53332.2.0.194 | NotificationregLowTempAlTrap_2 | current | Low regulation T.alarm | |
| 1.3.6.1.4.1.53332.2.0.195 | NotificationhighLimTempAlTrap_2 | current | High limit temp. alarm | |
| 1.3.6.1.4.1.53332.2.0.196 | NotificationlowLimTempAlTrap_2 | current | Low limit temp. alarm | |
| 1.3.6.1.4.1.53332.2.0.197 | NotificationretHighHumiAlTrap_2 | current | High room humidity alarm | |
| 1.3.6.1.4.1.53332.2.0.198 | NotificationretLowHumiAlTrap_2 | current | Low room humidity alarm | |
| 1.3.6.1.4.1.53332.2.0.199 | NotificationsupHighHumiAlTrap_2 | current | High supp.humidity alarm | |
| 1.3.6.1.4.1.53332.2.0.200 | NotificationsupLowHumiAlTrap_2 | current | Low supp.humidity alarm | |
| 1.3.6.1.4.1.53332.2.0.201 | NotificationprobeMod1COMTrap_2 | current | Module 1 communication | |
| 1.3.6.1.4.1.53332.2.0.202 | NotificationprobeMod1err1Trap_2 | current | Module 1 probe 1 alarm | |
| 1.3.6.1.4.1.53332.2.0.203 | NotificationprobeMod1err2Trap_2 | current | Module 1 probe 2 alarm | |
| 1.3.6.1.4.1.53332.2.0.204 | NotificationprobeMod1err3Trap_2 | current | Module 1 probe 3 alarm | |
| 1.3.6.1.4.1.53332.2.0.205 | NotificationprobeMod1err4Trap_2 | current | Module 1 probe 4 alarm | |
| 1.3.6.1.4.1.53332.2.0.206 | NotificationprobeMod1err5Trap_2 | current | Module 1 probe 5 alarm | |
| 1.3.6.1.4.1.53332.2.0.207 | NotificationprobeMod1err6Trap_2 | current | Module 1 probe 6 alarm | |
| 1.3.6.1.4.1.53332.2.0.208 | NotificationprobeMod2COMTrap_2 | current | Module 2 communication | |
| 1.3.6.1.4.1.53332.2.0.209 | NotificationprobeMod2err1Trap_2 | current | Module 2 probe 1 alarm | |
| 1.3.6.1.4.1.53332.2.0.210 | NotificationprobeMod2err2Trap_2 | current | Module 2 probe 2 alarm | |
| 1.3.6.1.4.1.53332.2.0.211 | NotificationprobeMod2err3Trap_2 | current | Module 2 probe 3 alarm | |
| 1.3.6.1.4.1.53332.2.0.212 | NotificationprobeMod2err4Trap_2 | current | Module 2 probe 4 alarm | |
| 1.3.6.1.4.1.53332.2.0.213 | NotificationprobeMod2err5Trap_2 | current | Module 2 probe 5 alarm | |
| 1.3.6.1.4.1.53332.2.0.214 | NotificationprobeMod2err6Trap_2 | current | Module 2 probe 6 alarm | |
| 1.3.6.1.4.1.53332.2.0.215 | NotificationprobeMod3COMTrap_2 | current | Module 3 communication | |
| 1.3.6.1.4.1.53332.2.0.216 | NotificationprobeMod3err1Trap_2 | current | Module 3 probe 1 alarm | |
| 1.3.6.1.4.1.53332.2.0.217 | NotificationprobeMod3err2Trap_2 | current | Module 3 probe 2 alarm | |
| 1.3.6.1.4.1.53332.2.0.218 | NotificationprobeMod3err3Trap_2 | current | Module 3 probe 3 alarm | |
| 1.3.6.1.4.1.53332.2.0.219 | NotificationprobeMod3err4Trap_2 | current | Module 3 probe 4 alarm | |
| 1.3.6.1.4.1.53332.2.0.220 | NotificationprobeMod3err5Trap_2 | current | Module 3 probe 5 alarm | |
| 1.3.6.1.4.1.53332.2.0.221 | NotificationprobeMod3err6Trap_2 | current | Module 3 probe 6 alarm | |
| 1.3.6.1.4.1.53332.2.1 | NodebinaryObjects2 | |||
| 1.3.6.1.4.1.53332.2.1.1 | ScalardamperStatusDI_2 | read-only | current | Motorised damper status |
| 1.3.6.1.4.1.53332.2.1.2 | ScalardirtyFilterDI_2 | read-only | current | Dirty filter alarm |
| 1.3.6.1.4.1.53332.2.1.3 | ScalarremoteOffDI_2 | read-only | current | Remote OFF status |
| 1.3.6.1.4.1.53332.2.1.4 | ScalarelHeaterAlarmDI_2 | read-only | current | Heater thermostat alarm |
| 1.3.6.1.4.1.53332.2.1.5 | ScalarcondPumpAlarmDI_2 | read-only | current | Condensate pump alarm |
| 1.3.6.1.4.1.53332.2.1.6 | ScalarconfigurableDI1_2 | read-only | current | Configurable DI 1 |
| 1.3.6.1.4.1.53332.2.1.7 | ScalarconfigurableDI2_2 | read-only | current | Configurable DI 2 |
| 1.3.6.1.4.1.53332.2.1.8 | ScalarconfigurableDI3_2 | read-only | current | Configurable DI 3 |
| 1.3.6.1.4.1.53332.2.1.9 | ScalarconfigurableDI4_2 | read-only | current | Configurable DI 4 |
| 1.3.6.1.4.1.53332.2.1.10 | ScalarconfigurableDI5_2 | read-only | current | Configurable DI 5 |
| 1.3.6.1.4.1.53332.2.1.11 | Scalarc1ThermAlarmDI_2 | read-only | current | Comp1 thermal alarm |
| 1.3.6.1.4.1.53332.2.1.12 | Scalarc1HPAlarmDI_2 | read-only | current | Comp1 high pressure alarm |
| 1.3.6.1.4.1.53332.2.1.13 | Scalarc1LPAlarmDI_2 | read-only | current | Comp1 low pressure alarm |
| 1.3.6.1.4.1.53332.2.1.14 | Scalarc2ThermAlarmDI_2 | read-only | current | Comp2 thermal alarm |
| 1.3.6.1.4.1.53332.2.1.15 | Scalarc2HPAlarmDI_2 | read-only | current | Comp2 high pressure alarm |
| 1.3.6.1.4.1.53332.2.1.16 | Scalarc2LPAlarmDI_2 | read-only | current | Comp2 low pressure alarm |
| 1.3.6.1.4.1.53332.2.1.17 | ScalarfansDO_2 | read-only | current | Fan control |
| 1.3.6.1.4.1.53332.2.1.18 | ScalardamperDO_2 | read-only | current | Motorised dampers control |
| 1.3.6.1.4.1.53332.2.1.19 | ScalarconfigurableDO1_2 | read-only | current | Configurable DO 1 |
| 1.3.6.1.4.1.53332.2.1.20 | ScalarconfigurableDO2_2 | read-only | current | Configurable DO 2 |
| 1.3.6.1.4.1.53332.2.1.21 | ScalarconfigurableDO3_2 | read-only | current | Configurable DO 3 |
| 1.3.6.1.4.1.53332.2.1.22 | ScalarconfigurableDO4_2 | read-only | current | Configurable DO 4 |
| 1.3.6.1.4.1.53332.2.1.23 | ScalarconfigurableDO5_2 | read-only | current | Configurable DO 5 |
| 1.3.6.1.4.1.53332.2.1.24 | ScalareHeaterStage1DO_2 | read-only | current | Electric heat stage 1 |
| 1.3.6.1.4.1.53332.2.1.25 | ScalareHeaterStage2DO_2 | read-only | current | Electric heat stage 2 |
| 1.3.6.1.4.1.53332.2.1.26 | Scalarcompressor1DO_2 | read-only | current | Compressor 1 control |
| 1.3.6.1.4.1.53332.2.1.27 | Scalarcompressor2DO_2 | read-only | current | Compressor 2 control |
| 1.3.6.1.4.1.53332.2.1.28 | ScalarhumPowerDO_2 | read-only | current | Humidifier control |
| 1.3.6.1.4.1.53332.2.1.29 | ScalarhumDrainValveDO_2 | read-only | current | Humidifier Discharge |
| 1.3.6.1.4.1.53332.2.1.30 | ScalarhumFillValveDO_2 | read-only | current | Humidifier Charging |
| 1.3.6.1.4.1.53332.2.1.31 | ScalarhumWaterLevel_2 | read-only | current | Humidifier high water |
| 1.3.6.1.4.1.53332.2.1.32 | ScalarsupervOFF_2 | read-write | current | ON/OFF from supervisor |
| 1.3.6.1.4.1.53332.2.1.33 | ScalarenableHumid_2 | read-write | current | Humidification enabling |
| 1.3.6.1.4.1.53332.2.1.34 | ScalarhumManualDrain_2 | read-write | current | Manual draining |
| 1.3.6.1.4.1.53332.2.1.35 | ScalarhumCylWashing_2 | read-write | current | Cylinder washing |
| 1.3.6.1.4.1.53332.2.1.36 | ScalartSManExchange_2 | read-write | current | TS manual exchange |
| 1.3.6.1.4.1.53332.2.1.37 | ScalartSTempExchEnab_2 | read-write | current | Enable TS room temp. exc. |
| 1.3.6.1.4.1.53332.2.1.38 | ScalardamperAlRes_2 | read-write | current | Reset damper status AL |
| 1.3.6.1.4.1.53332.2.1.39 | ScalarfireSmokeAlRes_2 | read-write | current | Reset smoke/fire AL |
| 1.3.6.1.4.1.53332.2.1.40 | ScalargenSerAlRes_2 | read-write | current | Reset generic serious AL |
| 1.3.6.1.4.1.53332.2.1.41 | ScalarfansGenAlRes_2 | read-write | current | Reset supply fan AL |
| 1.3.6.1.4.1.53332.2.1.42 | Scalarf1InvAlRes_2 | read-write | current | Reset fan 1 alarm |
| 1.3.6.1.4.1.53332.2.1.43 | Scalarf2InvAlRes_2 | read-write | current | Reset fan 2 alarm |
| 1.3.6.1.4.1.53332.2.1.44 | Scalarf3InvAlRes_2 | read-write | current | Reset fan 3 alarm |
| 1.3.6.1.4.1.53332.2.1.45 | Scalarf4InvAlRes_2 | read-write | current | Reset fan 4 alarm |
| 1.3.6.1.4.1.53332.2.1.46 | Scalarf5InvAlRes_2 | read-write | current | Reset fan 5 alarm |
| 1.3.6.1.4.1.53332.2.1.47 | Scalarf6InvAlRes_2 | read-write | current | Reset fan 6 alarm |
| 1.3.6.1.4.1.53332.2.1.48 | Scalarf7InvAlRes_2 | read-write | current | Reset fan 7 alarm |
| 1.3.6.1.4.1.53332.2.1.49 | Scalarf8InvAlRes_2 | read-write | current | Reset fan 8 alarm |
| 1.3.6.1.4.1.53332.2.1.50 | Scalarf9InvAlRes_2 | read-write | current | Reset fan 9 alarm |
| 1.3.6.1.4.1.53332.2.1.51 | Scalarf10InvAlRes_2 | read-write | current | Reset fan 10 alarm |
| 1.3.6.1.4.1.53332.2.1.52 | ScalarinvCompAlRes_2 | read-write | current | Reset inverter alarm |
| 1.3.6.1.4.1.53332.2.1.53 | Scalarc1ThermAlRes_2 | read-write | current | Reset C1 thermal AL |
| 1.3.6.1.4.1.53332.2.1.54 | Scalarc1HighPresAlRes_2 | read-write | current | Reset C1 high pressure AL |
| 1.3.6.1.4.1.53332.2.1.55 | Scalarc1LowPresAlRes_2 | read-write | current | Reset C1 low pressure AL |
| 1.3.6.1.4.1.53332.2.1.56 | Scalarc1HighDisTAlRes_2 | read-write | current | Reset C1 high disch. AL |
| 1.3.6.1.4.1.53332.2.1.57 | Scalarc1LCompRatAlRes_2 | read-write | current | Reset C1 low compres. AL |
| 1.3.6.1.4.1.53332.2.1.58 | Scalarcondenser1AlRes_2 | read-write | current | Reset condenser 1 AL |
| 1.3.6.1.4.1.53332.2.1.59 | ScalareEV1AlRes_2 | read-write | current | Reset EEV1 alarm |
| 1.3.6.1.4.1.53332.2.1.60 | Scalarc2ThermAlRes_2 | read-write | current | Reset C2 thermal AL |
| 1.3.6.1.4.1.53332.2.1.61 | Scalarc2HighPresAlRes_2 | read-write | current | Reset C2 high pressure AL |
| 1.3.6.1.4.1.53332.2.1.62 | Scalarc2LowPresAlRes_2 | read-write | current | Reset C2 low pressure AL |
| 1.3.6.1.4.1.53332.2.1.63 | Scalarc2HighDisTAlRes_2 | read-write | current | Reset C2 high disch. AL |
| 1.3.6.1.4.1.53332.2.1.64 | Scalarc2LComRatAlRes_2 | read-write | current | Reset C2 low compres. AL |
| 1.3.6.1.4.1.53332.2.1.65 | Scalarcondenser2AlRes_2 | read-write | current | Reset condenser 2 AL |
| 1.3.6.1.4.1.53332.2.1.66 | ScalareEV2AlRes_2 | read-write | current | Reset EEV2 alarm |
| 1.3.6.1.4.1.53332.2.1.67 | ScalarintHumidifAlRes_2 | read-write | current | Reset int. humidifier AL |
| 1.3.6.1.4.1.53332.2.1.68 | ScalarwatPresAlRes_2 | read-write | current | Reset water presence AL |
| 1.3.6.1.4.1.53332.2.1.69 | ScalardrainPumpAlRes_2 | read-write | current | Reset drain pump AL |
| 1.3.6.1.4.1.53332.2.1.70 | ScalarelHeatAlRes_2 | read-write | current | Reset electric heater AL |
| 1.3.6.1.4.1.53332.2.1.71 | ScalarfilterAlRes_2 | read-write | current | Reset dirty filter AL |
| 1.3.6.1.4.1.53332.2.1.72 | ScalardryCoolerAlRes_2 | read-write | current | Reset dry cooler AL |
| 1.3.6.1.4.1.53332.2.1.73 | ScalarextHumidifAlRes_2 | read-write | current | Reset ext. humidifier AL |
| 1.3.6.1.4.1.53332.2.1.74 | ScalarwaterPumpAlRes_2 | read-write | current | Reset water pump AL |
| 1.3.6.1.4.1.53332.2.1.75 | ScalarcondUnitGAlRes_2 | read-write | current | Reset motocondenser AL |
| 1.3.6.1.4.1.53332.2.1.76 | ScalargasLeakAlRes_2 | read-write | current | Reset gas leak AL |
| 1.3.6.1.4.1.53332.2.1.77 | ScalarpowerSupAlRes_2 | read-write | current | Reset power fault AL |
| 1.3.6.1.4.1.53332.2.1.78 | ScalargenSoftAlRes_2 | read-write | current | Reset generic soft AL |
| 1.3.6.1.4.1.53332.2.2 | NodescalarsObjects2 | |||
| 1.3.6.1.4.1.53332.2.2.1 | ScalarconfDI1Combo_2 | read-only | current | Configurable DI1 meaning |
| 1.3.6.1.4.1.53332.2.2.2 | ScalarconfDI2Combo_2 | read-only | current | Configurable DI2 meaning |
| 1.3.6.1.4.1.53332.2.2.3 | ScalarconfDI3Combo_2 | read-only | current | Configurable DI3 meaning |
| 1.3.6.1.4.1.53332.2.2.4 | ScalarconfDI4Combo_2 | read-only | current | Configurable DI4 meaning |
| 1.3.6.1.4.1.53332.2.2.5 | ScalarconfDI5Combo_2 | read-only | current | Configurable DI5 meaning |
| 1.3.6.1.4.1.53332.2.2.6 | ScalarconfDO1Combo_2 | read-only | current | Configurable DO1 meaning |
| 1.3.6.1.4.1.53332.2.2.7 | ScalarconfDO2Combo_2 | read-only | current | Configurable DO2 meaning |
| 1.3.6.1.4.1.53332.2.2.8 | ScalarconfDO3Combo_2 | read-only | current | Configurable DO3 meaning |
| 1.3.6.1.4.1.53332.2.2.9 | ScalarconfDO4Combo_2 | read-only | current | Configurable DO4 meaning |
| 1.3.6.1.4.1.53332.2.2.10 | ScalarconfDO5Combo_2 | read-only | current | Configurable DO5 meaning |
| 1.3.6.1.4.1.53332.2.2.11 | ScalarreturnTemp_2 | read-only | current | Return temperature |
| 1.3.6.1.4.1.53332.2.2.12 | ScalarreturnTAvg_2 | read-only | current | Return temperature (AVG) |
| 1.3.6.1.4.1.53332.2.2.13 | ScalarsupplyTemp_2 | read-only | current | Supply temperature |
| 1.3.6.1.4.1.53332.2.2.14 | ScalarsupplyTAvg_2 | read-only | current | Supply temperature (AVG) |
| 1.3.6.1.4.1.53332.2.2.15 | ScalartempDelta_2 | read-only | current | Temperature delta |
| 1.3.6.1.4.1.53332.2.2.16 | ScalarreturnHumidity_2 | read-only | current | Return humidity |
| 1.3.6.1.4.1.53332.2.2.17 | ScalarreturnHumAvg_2 | read-only | current | Return humidity (AVG) |
| 1.3.6.1.4.1.53332.2.2.18 | ScalarsupplyHumidity_2 | read-only | current | Supply humidity |
| 1.3.6.1.4.1.53332.2.2.19 | ScalarsupplyHumAvg_2 | read-only | current | Supply humidity (AVG) |
| 1.3.6.1.4.1.53332.2.2.20 | ScalarairFlow_2 | read-only | current | Air flow |
| 1.3.6.1.4.1.53332.2.2.22 | ScalarairPressure_2 | read-only | current | Air pressure |
| 1.3.6.1.4.1.53332.2.2.23 | ScalarairPressureAvg_2 | read-only | current | Air pressure (Average) |
| 1.3.6.1.4.1.53332.2.2.24 | ScalarnetMod1Combo1_2 | read-only | current | Module 1 - Probe 1 status |
| 1.3.6.1.4.1.53332.2.2.25 | ScalarnetMod1Probe1_2 | read-only | current | Module 1 - Probe 1 value |
| 1.3.6.1.4.1.53332.2.2.26 | ScalarnetMod1Combo2_2 | read-only | current | Module 1 - Probe 2 status |
| 1.3.6.1.4.1.53332.2.2.27 | ScalarnetMod1Probe2_2 | read-only | current | Module 1 - Probe 2 value |
| 1.3.6.1.4.1.53332.2.2.28 | ScalarnetMod1Combo3_2 | read-only | current | Module 1 - Probe 3 status |
| 1.3.6.1.4.1.53332.2.2.29 | ScalarnetMod1Probe3_2 | read-only | current | Module 1 - Probe 3 value |
| 1.3.6.1.4.1.53332.2.2.30 | ScalarnetMod1Combo4_2 | read-only | current | Module 1 - Probe 4 status |
| 1.3.6.1.4.1.53332.2.2.31 | ScalarnetMod1Probe4_2 | read-only | current | Module 1 - Probe 4 value |
| 1.3.6.1.4.1.53332.2.2.32 | ScalarnetMod1Combo5_2 | read-only | current | Module 1 - Probe 5 status |
| 1.3.6.1.4.1.53332.2.2.33 | ScalarnetMod1Probe5_2 | read-only | current | Module 1 - Probe 5 value |
| 1.3.6.1.4.1.53332.2.2.34 | ScalarnetMod1Combo6_2 | read-only | current | Module 1 - Probe 6 status |
| 1.3.6.1.4.1.53332.2.2.35 | ScalarnetMod1Probe6_2 | read-only | current | Module 1 - Probe 6 value |
| 1.3.6.1.4.1.53332.2.2.36 | ScalarnetMod2Combo1_2 | read-only | current | Module 2 - Probe 1 status |
| 1.3.6.1.4.1.53332.2.2.37 | ScalarnetMod2Probe1_2 | read-only | current | Module 2 - Probe 1 value |
| 1.3.6.1.4.1.53332.2.2.38 | ScalarnetMod2Combo2_2 | read-only | current | Module 2 - Probe 2 status |
| 1.3.6.1.4.1.53332.2.2.39 | ScalarnetMod2Probe2_2 | read-only | current | Module 2 - Probe 2 value |
| 1.3.6.1.4.1.53332.2.2.40 | ScalarnetMod2Combo3_2 | read-only | current | Module 2 - Probe 3 status |
| 1.3.6.1.4.1.53332.2.2.41 | ScalarnetMod2Probe3_2 | read-only | current | Module 2 - Probe 3 value |
| 1.3.6.1.4.1.53332.2.2.42 | ScalarnetMod2Combo4_2 | read-only | current | Module 2 - Probe 4 status |
| 1.3.6.1.4.1.53332.2.2.43 | ScalarnetMod2Probe4_2 | read-only | current | Module 2 - Probe 4 value |
| 1.3.6.1.4.1.53332.2.2.44 | ScalarnetMod2Combo5_2 | read-only | current | Module 2 - Probe 5 status |
| 1.3.6.1.4.1.53332.2.2.45 | ScalarnetMod2Probe5_2 | read-only | current | Module 2 - Probe 5 value |
| 1.3.6.1.4.1.53332.2.2.46 | ScalarnetMod2Combo6_2 | read-only | current | Module 2 - Probe 6 status |
| 1.3.6.1.4.1.53332.2.2.47 | ScalarnetMod2Probe6_2 | read-only | current | Module 2 - Probe 6 value |
| 1.3.6.1.4.1.53332.2.2.48 | ScalarnetMod3Combo1_2 | read-only | current | Module 3 - Probe 1 status |
| 1.3.6.1.4.1.53332.2.2.49 | ScalarnetMod3Probe1_2 | read-only | current | Module 3 - Probe 1 value |
| 1.3.6.1.4.1.53332.2.2.50 | ScalarnetMod3Combo2_2 | read-only | current | Module 3 - Probe 2 status |
| 1.3.6.1.4.1.53332.2.2.51 | ScalarnetMod3Probe2_2 | read-only | current | Module 3 - Probe 2 value |
| 1.3.6.1.4.1.53332.2.2.52 | ScalarnetMod3Combo3_2 | read-only | current | Module 3 - Probe 3 status |
| 1.3.6.1.4.1.53332.2.2.53 | ScalarnetMod3Probe3_2 | read-only | current | Module 3 - Probe 3 value |
| 1.3.6.1.4.1.53332.2.2.54 | ScalarnetMod3Combo4_2 | read-only | current | Module 3 - Probe 4 status |
| 1.3.6.1.4.1.53332.2.2.55 | ScalarnetMod3Probe4_2 | read-only | current | Module 3 - Probe 4 value |
| 1.3.6.1.4.1.53332.2.2.56 | ScalarnetMod3Combo5_2 | read-only | current | Module 3 - Probe 5 status |
| 1.3.6.1.4.1.53332.2.2.57 | ScalarnetMod3Probe5_2 | read-only | current | Module 3 - Probe 5 value |
| 1.3.6.1.4.1.53332.2.2.58 | ScalarnetMod3Combo6_2 | read-only | current | Module 3 - Probe 6 status |
| 1.3.6.1.4.1.53332.2.2.59 | ScalarnetMod3Probe6_2 | read-only | current | Module 3 - Probe 6 value |
| 1.3.6.1.4.1.53332.2.2.60 | ScalaravgModTemp_2 | read-only | current | Modules temperatures AVG |
| 1.3.6.1.4.1.53332.2.2.61 | ScalaravgModHumi_2 | read-only | current | Modules humidity AVG |
| 1.3.6.1.4.1.53332.2.2.62 | ScalaravgModPress_2 | read-only | current | Modules pressure AVG |
| 1.3.6.1.4.1.53332.2.2.63 | ScalardryCoolerAO_2 | read-only | current | Supply Fan/Dry cooler |
| 1.3.6.1.4.1.53332.2.2.64 | ScalarcoolingAO_2 | read-only | current | Cooling valve/FC/Inverter |
| 1.3.6.1.4.1.53332.2.2.65 | ScalarheatingAO_2 | read-only | current | Heating valve/Heater |
| 1.3.6.1.4.1.53332.2.2.66 | ScalartwoSources2AO_2 | read-only | current | TS cooling valve 2 |
| 1.3.6.1.4.1.53332.2.2.67 | Scalarcondenser1AO_2 | read-only | current | Condenser 1 |
| 1.3.6.1.4.1.53332.2.2.68 | Scalarcond2HumidifAO_2 | read-only | current | Condenser 2/Humidifier |
| 1.3.6.1.4.1.53332.2.2.69 | ScalarunitStatus_2 | read-only | current | Unit status |
| 1.3.6.1.4.1.53332.2.2.70 | ScalarfanSpeed_2 | read-only | current | Fan speed |
| 1.3.6.1.4.1.53332.2.2.71 | Scalarfan1Actspeed_2 | read-only | current | Fan 1 speed |
| 1.3.6.1.4.1.53332.2.2.72 | Scalarfan1ActRPM_2 | read-only | current | Fan 1 speed RPM |
| 1.3.6.1.4.1.53332.2.2.73 | Scalarfan1Cur_2 | read-only | current | Fan 1 current |
| 1.3.6.1.4.1.53332.2.2.74 | Scalarfan1Power_2 | read-only | current | Fan 1 power |
| 1.3.6.1.4.1.53332.2.2.75 | Scalarfan2Actspeed_2 | read-only | current | Fan 2 speed |
| 1.3.6.1.4.1.53332.2.2.76 | Scalarfan2ActRPM_2 | read-only | current | Fan 2 speed RPM |
| 1.3.6.1.4.1.53332.2.2.77 | Scalarfan2Cur_2 | read-only | current | Fan 2 current |
| 1.3.6.1.4.1.53332.2.2.78 | Scalarfan2Power_2 | read-only | current | Fan 2 power |
| 1.3.6.1.4.1.53332.2.2.79 | Scalarfan3Actspeed_2 | read-only | current | Fan 3 speed |
| 1.3.6.1.4.1.53332.2.2.80 | Scalarfan3ActRPM_2 | read-only | current | Fan 3 speed RPM |
| 1.3.6.1.4.1.53332.2.2.81 | Scalarfan3Cur_2 | read-only | current | Fan 3 current |
| 1.3.6.1.4.1.53332.2.2.82 | Scalarfan3Power_2 | read-only | current | Fan 3 power |
| 1.3.6.1.4.1.53332.2.2.83 | Scalarfan4Actspeed_2 | read-only | current | Fan 4 speed |
| 1.3.6.1.4.1.53332.2.2.84 | Scalarfan4ActRPM_2 | read-only | current | Fan 4 speed RPM |
| 1.3.6.1.4.1.53332.2.2.85 | Scalarfan4Cur_2 | read-only | current | Fan 4 current |
| 1.3.6.1.4.1.53332.2.2.86 | Scalarfan4Power_2 | read-only | current | Fan 4 power |
| 1.3.6.1.4.1.53332.2.2.87 | Scalarfan5Actspeed_2 | read-only | current | Fan 5 speed |
| 1.3.6.1.4.1.53332.2.2.88 | Scalarfan5ActRPM_2 | read-only | current | Fan 5 speed RPM |
| 1.3.6.1.4.1.53332.2.2.89 | Scalarfan5Cur_2 | read-only | current | Fan 5 current |
| 1.3.6.1.4.1.53332.2.2.90 | Scalarfan5Power_2 | read-only | current | Fan 5 power |
| 1.3.6.1.4.1.53332.2.2.91 | Scalarfan6Actspeed_2 | read-only | current | Fan 6 speed |
| 1.3.6.1.4.1.53332.2.2.92 | Scalarfan6ActRPM_2 | read-only | current | Fan 6 speed RPM |
| 1.3.6.1.4.1.53332.2.2.93 | Scalarfan6Cur_2 | read-only | current | Fan 6 current |
| 1.3.6.1.4.1.53332.2.2.94 | Scalarfan6Power_2 | read-only | current | Fan 6 power |
| 1.3.6.1.4.1.53332.2.2.95 | Scalarfan7Actspeed_2 | read-only | current | Fan 7 speed |
| 1.3.6.1.4.1.53332.2.2.96 | Scalarfan7ActRPM_2 | read-only | current | Fan 7 speed RPM |
| 1.3.6.1.4.1.53332.2.2.97 | Scalarfan7Cur_2 | read-only | current | Fan 7 current |
| 1.3.6.1.4.1.53332.2.2.98 | Scalarfan7Power_2 | read-only | current | Fan 7 power |
| 1.3.6.1.4.1.53332.2.2.99 | Scalarfan8Actspeed_2 | read-only | current | Fan 8 speed |
| 1.3.6.1.4.1.53332.2.2.100 | Scalarfan8ActRPM_2 | read-only | current | Fan 8 speed RPM |
| 1.3.6.1.4.1.53332.2.2.101 | Scalarfan8Cur_2 | read-only | current | Fan 8 current |
| 1.3.6.1.4.1.53332.2.2.102 | Scalarfan8Power_2 | read-only | current | Fan 8 power |
| 1.3.6.1.4.1.53332.2.2.103 | Scalarfan9Actspeed_2 | read-only | current | Fan 9 speed |
| 1.3.6.1.4.1.53332.2.2.104 | Scalarfan9ActRPM_2 | read-only | current | Fan 9 speed RPM |
| 1.3.6.1.4.1.53332.2.2.105 | Scalarfan9Cur_2 | read-only | current | Fan 9 current |
| 1.3.6.1.4.1.53332.2.2.106 | Scalarfan9Power_2 | read-only | current | Fan 9 power |
| 1.3.6.1.4.1.53332.2.2.107 | Scalarfan10Actspeed_2 | read-only | current | Fan 10 speed |
| 1.3.6.1.4.1.53332.2.2.108 | Scalarfan10ActRPM_2 | read-only | current | Fan 10 speed RPM |
| 1.3.6.1.4.1.53332.2.2.109 | Scalarfan10Cur_2 | read-only | current | Fan 10 current |
| 1.3.6.1.4.1.53332.2.2.110 | Scalarfan10Power_2 | read-only | current | Fan 10 power |
| 1.3.6.1.4.1.53332.2.2.111 | ScalardiffFilterPres_2 | read-only | current | Dirty filter pressure |
| 1.3.6.1.4.1.53332.2.2.112 | ScalarcoolingRequest_2 | read-only | current | Cooling request |
| 1.3.6.1.4.1.53332.2.2.113 | ScalarheatingRequest_2 | read-only | current | Heating request |
| 1.3.6.1.4.1.53332.2.2.114 | ScalardehumidRequest_2 | read-only | current | Dehumidification request |
| 1.3.6.1.4.1.53332.2.2.115 | ScalarhumidifRequest_2 | read-only | current | Humidification request |
| 1.3.6.1.4.1.53332.2.2.116 | ScalartempFcTs_2 | read-only | current | FC/TS temperature |
| 1.3.6.1.4.1.53332.2.2.117 | ScalarfCTSStatus_2 | read-only | current | FC/TS status |
| 1.3.6.1.4.1.53332.2.2.118 | ScalarfCRequest_2 | read-only | current | Free cooling request |
| 1.3.6.1.4.1.53332.2.2.119 | ScalaractiveComp_2 | read-only | current | Active compressor |
| 1.3.6.1.4.1.53332.2.2.120 | Scalarcomp1Sts_2 | read-only | current | Compressor 1 Status |
| 1.3.6.1.4.1.53332.2.2.121 | Scalarcomp2Sts_2 | read-only | current | Compressor 2 Status |
| 1.3.6.1.4.1.53332.2.2.122 | ScalarinvComprReq_2 | read-only | current | Inverter compressor request |
| 1.3.6.1.4.1.53332.2.2.123 | ScalarinvCompHz_2 | read-only | current | Inverter frequency |
| 1.3.6.1.4.1.53332.2.2.124 | ScalarinvCompPower_2 | read-only | current | Inverter power input |
| 1.3.6.1.4.1.53332.2.2.125 | ScalarinvCompCurrent_2 | read-only | current | Inverter absorbed current |
| 1.3.6.1.4.1.53332.2.2.126 | Scalarc1EvapPres_2 | read-only | current | C1 evaporation pressure |
| 1.3.6.1.4.1.53332.2.2.127 | Scalarc1EvapTemp_2 | read-only | current | C1 evaporation temperature |
| 1.3.6.1.4.1.53332.2.2.128 | Scalarc1SuctionTemp_2 | read-only | current | C1 suction temperature |
| 1.3.6.1.4.1.53332.2.2.129 | Scalarc1Superheat_2 | read-only | current | C1 super-heating |
| 1.3.6.1.4.1.53332.2.2.130 | Scalarc1CompRatio_2 | read-only | current | C1 compression ratio |
| 1.3.6.1.4.1.53332.2.2.131 | Scalarc1DischTemp_2 | read-only | current | C1 discharge temperature |
| 1.3.6.1.4.1.53332.2.2.132 | Scalarc1CondPress_2 | read-only | current | C1 condensation pressure |
| 1.3.6.1.4.1.53332.2.2.133 | Scalarc1CondTemp_2 | read-only | current | C1 condensation temperature |
| 1.3.6.1.4.1.53332.2.2.134 | Scalarc1Desuperheat_2 | read-only | current | C1 de-superheating |
| 1.3.6.1.4.1.53332.2.2.135 | Scalarc1LiquidTemp_2 | read-only | current | C1 liquid temperature |
| 1.3.6.1.4.1.53332.2.2.136 | Scalarc1Subcooling_2 | read-only | current | C1 sub-cooling |
| 1.3.6.1.4.1.53332.2.2.137 | ScalareEV1SHSet_2 | read-only | current | EEV1 super-heating set-point |
| 1.3.6.1.4.1.53332.2.2.138 | ScalareEV1Position_2 | read-only | current | EEV1 position |
| 1.3.6.1.4.1.53332.2.2.139 | ScalareEV1Status_2 | read-only | current | EEV1 working status |
| 1.3.6.1.4.1.53332.2.2.140 | Scalarcond1ActualSet_2 | read-only | current | Condenser 1 current set |
| 1.3.6.1.4.1.53332.2.2.141 | Scalarcond1Req_2 | read-only | current | Condenser 1 request |
| 1.3.6.1.4.1.53332.2.2.142 | Scalarc2EvapPres_2 | read-only | current | C2 evaporation pressure |
| 1.3.6.1.4.1.53332.2.2.143 | Scalarc2EvapTemp_2 | read-only | current | C2 evaporation temperature |
| 1.3.6.1.4.1.53332.2.2.144 | Scalarc2SuctionTemp_2 | read-only | current | C2 suction temperature |
| 1.3.6.1.4.1.53332.2.2.145 | Scalarc2Superheat_2 | read-only | current | C2 super-heating |
| 1.3.6.1.4.1.53332.2.2.146 | Scalarc2CompRatio_2 | read-only | current | C2 compression ratio |
| 1.3.6.1.4.1.53332.2.2.147 | Scalarc2DischTemp_2 | read-only | current | C2 discharge temperature |
| 1.3.6.1.4.1.53332.2.2.148 | Scalarc2CondPress_2 | read-only | current | C2 condensation pressure |
| 1.3.6.1.4.1.53332.2.2.149 | Scalarc2CondTemp_2 | read-only | current | C2 condensation temperature |
| 1.3.6.1.4.1.53332.2.2.150 | Scalarc2Desuperheat_2 | read-only | current | C2 de-superheating |
| 1.3.6.1.4.1.53332.2.2.151 | Scalarc2LiquidTemp_2 | read-only | current | C2 liquid temperature |
| 1.3.6.1.4.1.53332.2.2.152 | Scalarc2Subcooling_2 | read-only | current | C2 sub-cooling |
| 1.3.6.1.4.1.53332.2.2.153 | ScalareEV2SHSet_2 | read-only | current | EEV2 superheat set-point |
| 1.3.6.1.4.1.53332.2.2.154 | ScalareEV2Position_2 | read-only | current | EEV2 position |
| 1.3.6.1.4.1.53332.2.2.155 | ScalareEV2Status_2 | read-only | current | EEV2 working status |
| 1.3.6.1.4.1.53332.2.2.156 | Scalarcond2ActualSet_2 | read-only | current | Condenser 2 current set |
| 1.3.6.1.4.1.53332.2.2.157 | Scalarcond2Req_2 | read-only | current | Condenser 2 request |
| 1.3.6.1.4.1.53332.2.2.158 | ScalarwaterINTemp1_2 | read-only | current | Water IN temperature 1 |
| 1.3.6.1.4.1.53332.2.2.159 | ScalarwaterOUTTemp1_2 | read-only | current | Water OUT temperature 1 |
| 1.3.6.1.4.1.53332.2.2.160 | ScalarwaterDT1_2 | read-only | current | Water temperature delta 1 |
| 1.3.6.1.4.1.53332.2.2.161 | ScalarwaterFlow1_2 | read-only | current | Water flow rate 1 |
| 1.3.6.1.4.1.53332.2.2.162 | ScalaractWatFlowSet1_2 | read-only | current | Actual water flow set 1 |
| 1.3.6.1.4.1.53332.2.2.163 | ScalarwaterCoolCap1_2 | read-only | current | Water cooling capacity 1 |
| 1.3.6.1.4.1.53332.2.2.164 | ScalareER1_2 | read-only | current | EER 1 |
| 1.3.6.1.4.1.53332.2.2.165 | Scalarvalve1Position_2 | read-only | current | Water valve 1 position |
| 1.3.6.1.4.1.53332.2.2.166 | ScalarwaterINTemp2_2 | read-only | current | Water IN temperature 2 |
| 1.3.6.1.4.1.53332.2.2.167 | ScalarwaterOUTTemp2_2 | read-only | current | Water OUT temperature 2 |
| 1.3.6.1.4.1.53332.2.2.168 | ScalarwaterDT2_2 | read-only | current | Water temperature delta 2 |
| 1.3.6.1.4.1.53332.2.2.169 | ScalarwaterFlow2_2 | read-only | current | Water flow rate 2 |
| 1.3.6.1.4.1.53332.2.2.170 | ScalaractWatFlowSet2_2 | read-only | current | Actual water flow set 2 |
| 1.3.6.1.4.1.53332.2.2.171 | ScalarwaterCoolCap2_2 | read-only | current | Water cooling capacity 2 |
| 1.3.6.1.4.1.53332.2.2.172 | ScalareER2_2 | read-only | current | EER 2 |
| 1.3.6.1.4.1.53332.2.2.173 | Scalarvalve2Position_2 | read-only | current | Water valve 2 position |
| 1.3.6.1.4.1.53332.2.2.174 | ScalarhumSteamProd_2 | read-only | current | Current steam production |
| 1.3.6.1.4.1.53332.2.2.175 | ScalarhumWaterConduct_2 | read-only | current | Humidifier conductivity |
| 1.3.6.1.4.1.53332.2.2.176 | ScalarhumCurrent_2 | read-only | current | Humidifier abs. Current |
| 1.3.6.1.4.1.53332.2.2.177 | ScalarhumWorkingMode_2 | read-only | current | Humidifier operating mode |
| 1.3.6.1.4.1.53332.2.2.178 | ScalarhumWorkStatus_2 | read-only | current | Humidifier operating status |
| 1.3.6.1.4.1.53332.2.2.179 | ScalarheaterReq_2 | read-only | current | Electric heater request |
| 1.3.6.1.4.1.53332.2.2.180 | ScalarheaterActiveStg_2 | read-only | current | Number of active stages |
| 1.3.6.1.4.1.53332.2.2.181 | ScalarelHeaterPower_2 | read-only | current | Electric heater power |
| 1.3.6.1.4.1.53332.2.2.182 | ScalarheatValveReq_2 | read-only | current | Hot water valve request |
| 1.3.6.1.4.1.53332.2.2.183 | ScalardryCoolerActSet_2 | read-only | current | Current dry cooler set |
| 1.3.6.1.4.1.53332.2.2.184 | ScalardryCoolerReq_2 | read-only | current | Dry cooler request |
| 1.3.6.1.4.1.53332.2.2.185 | ScalarunitWH_2 | read-only | current | Unit working hours |
| 1.3.6.1.4.1.53332.2.2.186 | Scalarc1WH_2 | read-only | current | Compressor1 working hours |
| 1.3.6.1.4.1.53332.2.2.187 | Scalarc1Startup_2 | read-only | current | Compressor 1 startups |
| 1.3.6.1.4.1.53332.2.2.188 | Scalarc2WH_2 | read-only | current | Compressor2 working hours |
| 1.3.6.1.4.1.53332.2.2.189 | Scalarc2Startup_2 | read-only | current | Compressor 2 startups |
| 1.3.6.1.4.1.53332.2.2.190 | ScalarcoolValveWH_2 | read-only | current | Cooling working hours |
| 1.3.6.1.4.1.53332.2.2.191 | ScalarheatingWH_2 | read-only | current | Heating working hours |
| 1.3.6.1.4.1.53332.2.2.192 | ScalarhumidifWH_2 | read-only | current | Humidifier working hours |
| 1.3.6.1.4.1.53332.2.2.193 | ScalarfreeCoolWH_2 | read-only | current | FC working hours |
| 1.3.6.1.4.1.53332.2.2.194 | ScalardryCoolerWH_2 | read-only | current | Dry cooler working hours |
| 1.3.6.1.4.1.53332.2.2.195 | Scalarcond1WH_2 | read-only | current | Condenser1 working hours |
| 1.3.6.1.4.1.53332.2.2.196 | Scalarcond2WH_2 | read-only | current | Condenser2 working hours |
| 1.3.6.1.4.1.53332.2.2.197 | ScalartempSetpoint_2 | read-write | current | Temperature set-point |
| 1.3.6.1.4.1.53332.2.2.198 | ScalarhumSetpoint_2 | read-write | current | Humidity set-point |
| 1.3.6.1.4.1.53332.2.2.199 | ScalarairFlowSetpoint_2 | read-write | current | Air flow set-point |
| 1.3.6.1.4.1.53332.2.2.200 | ScalarairPresSetpoint_2 | read-write | current | Air pressure set-point |
| 1.3.6.1.4.1.53332.2.2.201 | ScalarairDTSetpoint_2 | read-write | current | Air temperature delta set |
| 1.3.6.1.4.1.53332.2.2.202 | ScalartempControlSel_2 | read-write | current | Regulation sensor |
| 1.3.6.1.4.1.53332.2.2.203 | ScalartempControlType_2 | read-write | current | Regulation type |
| 1.3.6.1.4.1.53332.2.2.204 | ScalartPropBand_2 | read-write | current | Proportional Band |
| 1.3.6.1.4.1.53332.2.2.205 | ScalartIntegralTime_2 | read-write | current | Integration time |
| 1.3.6.1.4.1.53332.2.2.206 | ScalartDerivativeTime_2 | read-write | current | Derivative time |
| 1.3.6.1.4.1.53332.2.2.207 | ScalarhighTAlOffset_2 | read-write | current | High temperature offset |
| 1.3.6.1.4.1.53332.2.2.208 | ScalarlowTAlOffset_2 | read-write | current | Low temperature offset |
| 1.3.6.1.4.1.53332.2.2.209 | ScalarhighLimitTThr_2 | read-write | current | High limit temp. thresh. |
| 1.3.6.1.4.1.53332.2.2.210 | ScalarhighLimitTMng_2 | read-write | current | High limit temp. managem. |
| 1.3.6.1.4.1.53332.2.2.211 | ScalarlowLimitTThr_2 | read-write | current | Low limit temp.thresh. |
| 1.3.6.1.4.1.53332.2.2.212 | ScalarlowLimitTMng_2 | read-write | current | Low limit temp. managem. |
| 1.3.6.1.4.1.53332.2.2.213 | ScalardehumPropBand_2 | read-write | current | Dehumid. proportion. band |
| 1.3.6.1.4.1.53332.2.2.214 | ScalarhumPropBand_2 | read-write | current | Humid. proportion. band |
| 1.3.6.1.4.1.53332.2.2.215 | ScalarhRetHAlOffset_2 | read-write | current | High humidity offset |
| 1.3.6.1.4.1.53332.2.2.216 | ScalarlRetHAlOffset_2 | read-write | current | Low humidity offset |
| 1.3.6.1.4.1.53332.2.2.217 | ScalarhighSupHumThr_2 | read-write | current | High supp. humidity thr. |
| 1.3.6.1.4.1.53332.2.2.218 | ScalarlowSupHumThr_2 | read-write | current | Low supp. humidity thr. |
| 1.3.6.1.4.1.53332.2.2.219 | ScalarfCDelta_2 | read-write | current | Free cooling delta |
| 1.3.6.1.4.1.53332.2.2.220 | ScalartSWaterSet_2 | read-write | current | Two sources set-point |
| 1.3.6.1.4.1.53332.2.2.221 | ScalartSWaterPropBand_2 | read-write | current | Two sources band |
| 1.3.6.1.4.1.53332.2.2.222 | ScalartSAirTempSet_2 | read-write | current | TS room temp. Exch. set |
| 1.3.6.1.4.1.53332.2.2.223 | ScalarcondSetpoint_2 | read-write | current | Condensation set-point |
| 1.3.6.1.4.1.53332.2.2.224 | ScalarcondPropoBand_2 | read-write | current | Condensation band |
| 1.3.6.1.4.1.53332.2.2.225 | ScalarcondSetIncrease_2 | read-write | current | Condensation set increase |
| 1.3.6.1.4.1.53332.2.2.226 | ScalarmaxCondSetpoint_2 | read-write | current | Maximum condensation set |
| 1.3.6.1.4.1.53332.2.2.227 | ScalardryCoolerSet_2 | read-write | current | Dry cooler set-point |
| 1.3.6.1.4.1.53332.2.2.228 | ScalardryCoolPropBand_2 | read-write | current | Dry cooler band |
| 1.3.6.1.4.1.53332.2.2.229 | ScalardryCoolSetIncr_2 | read-write | current | Dry Cooler set increase |
| 1.3.6.1.4.1.53332.2.2.230 | ScalarmaxDryCoolerSet_2 | read-write | current | Maximum dry Cooler set |
| 1.3.6.1.4.1.53332.2.2.231 | ScalardirtyFiltSet_2 | read-write | current | Dirty filter set-point |
| 1.3.6.1.4.1.53332.2.2.232 | ScalardirtyFiltDiff_2 | read-write | current | Dirty filter differential |
| 1.3.6.1.4.1.53332.2.2.233 | ScalarinvCompAlCode1_2 | read-only | current | DC Inverter alarm code 1 |
| 1.3.6.1.4.1.53332.2.2.234 | ScalarinvCompAlCode2_2 | read-only | current | DC Inverter alarm code 2 |
| 1.3.6.1.4.1.53332.2.2.235 | ScalarinvCompAlCode3_2 | read-only | current | DC Inverter alarm code 3 |
| 1.3.6.1.4.1.53332.2.2.236 | ScalarinvCompAlCode4_2 | read-only | current | DC Inverter alarm code 4 |
| 1.3.6.1.4.1.53332.2.2.237 | ScalarinvCompAlCode5_2 | read-only | current | DC Inverter alarm code 5 |
| 1.3.6.1.4.1.53332.2.3 | Nodealarms2 | |||
| 1.3.6.1.4.1.53332.2.3.1 | ScalargeneralAl_2 | read-only | current | General alarams |
| 1.3.6.1.4.1.53332.2.3.2 | ScalarnotCriticAl_2 | read-only | current | Not critical alarms |
| 1.3.6.1.4.1.53332.2.3.3 | ScalarcriticalAl_2 | read-only | current | Critical alarms |
| 1.3.6.1.4.1.53332.2.3.4 | ScalarfansAl_2 | read-only | current | Fans alarms |
| 1.3.6.1.4.1.53332.2.3.5 | ScalarcompAl_2 | read-only | current | Compressors alarms |
| 1.3.6.1.4.1.53332.2.3.6 | ScalartempAl_2 | read-only | current | Temperature alarms |
| 1.3.6.1.4.1.53332.2.3.7 | ScalarhumidityAl_2 | read-only | current | Humidity alarms |
| 1.3.6.1.4.1.53332.2.3.8 | ScalardamperAl_2 | read-only | current | Damper status alarm |
| 1.3.6.1.4.1.53332.2.3.9 | ScalarfireSmokeAl_2 | read-only | current | Fire/Smoke alarm |
| 1.3.6.1.4.1.53332.2.3.10 | ScalargSeriousAl_2 | read-only | current | Critical generic alarm |
| 1.3.6.1.4.1.53332.2.3.11 | ScalarfansGenAl_2 | read-only | current | General supply fans alarm |
| 1.3.6.1.4.1.53332.2.3.12 | Scalarf1GeneralAl_2 | read-only | current | Fan general alarm 1 |
| 1.3.6.1.4.1.53332.2.3.13 | Scalarf1PowerAl_2 | read-only | current | Phase failure/undervolt.1 |
| 1.3.6.1.4.1.53332.2.3.14 | Scalarf1CommAl_2 | read-only | current | Communication 1 |
| 1.3.6.1.4.1.53332.2.3.15 | Scalarf1HiTempAl_2 | read-only | current | Power mod overheated 1 |
| 1.3.6.1.4.1.53332.2.3.16 | Scalarf1NetComAl_2 | read-only | current | Master/Slave com. 1 |
| 1.3.6.1.4.1.53332.2.3.17 | Scalarf1InvRegAl_2 | read-only | current | Regulation module 1 |
| 1.3.6.1.4.1.53332.2.3.18 | Scalarf1HiMotTAl_2 | read-only | current | Motor overheated 1 |
| 1.3.6.1.4.1.53332.2.3.19 | Scalarf1HallSenAl_2 | read-only | current | Hall sensor error 1 |
| 1.3.6.1.4.1.53332.2.3.20 | Scalarf1OverlAl_2 | read-only | current | Locked motor 1 |
| 1.3.6.1.4.1.53332.2.3.21 | Scalarf1LowDCAl_2 | read-only | current | Low DC 1 |
| 1.3.6.1.4.1.53332.2.3.22 | Scalarf2GeneralAl_2 | read-only | current | Fan general alarm 2 |
| 1.3.6.1.4.1.53332.2.3.23 | Scalarf2PowerAl_2 | read-only | current | Phase failure/undervolt.2 |
| 1.3.6.1.4.1.53332.2.3.24 | Scalarf2CommAl_2 | read-only | current | Communication 2 |
| 1.3.6.1.4.1.53332.2.3.25 | Scalarf2HiTempAl_2 | read-only | current | Power mod overheated 2 |
| 1.3.6.1.4.1.53332.2.3.26 | Scalarf2NetComAl_2 | read-only | current | Master/Slave com. 2 |
| 1.3.6.1.4.1.53332.2.3.27 | Scalarf2InvRegAl_2 | read-only | current | Regulation module 2 |
| 1.3.6.1.4.1.53332.2.3.28 | Scalarf2HiMotTAl_2 | read-only | current | Motor overheated 2 |
| 1.3.6.1.4.1.53332.2.3.29 | Scalarf2HallSenAl_2 | read-only | current | Hall sensor error 2 |
| 1.3.6.1.4.1.53332.2.3.30 | Scalarf2OverlAl_2 | read-only | current | Locked motor 2 |
| 1.3.6.1.4.1.53332.2.3.31 | Scalarf2LowDCAl_2 | read-only | current | Low DC 2 |
| 1.3.6.1.4.1.53332.2.3.32 | Scalarf3GeneralAl_2 | read-only | current | Fan general alarm 3 |
| 1.3.6.1.4.1.53332.2.3.33 | Scalarf3PowerAl_2 | read-only | current | Phase failure/undervolt.3 |
| 1.3.6.1.4.1.53332.2.3.34 | Scalarf3CommAl_2 | read-only | current | Communication 3 |
| 1.3.6.1.4.1.53332.2.3.35 | Scalarf3HiTempAl_2 | read-only | current | Power mod overheated 3 |
| 1.3.6.1.4.1.53332.2.3.36 | Scalarf3NetComAl_2 | read-only | current | Master/Slave com. 3 |
| 1.3.6.1.4.1.53332.2.3.37 | Scalarf3InvRegAl_2 | read-only | current | Regulation module 3 |
| 1.3.6.1.4.1.53332.2.3.38 | Scalarf3HiMotTAl_2 | read-only | current | Motor overheated 3 |
| 1.3.6.1.4.1.53332.2.3.39 | Scalarf3HallSenAl_2 | read-only | current | Hall sensor error 3 |
| 1.3.6.1.4.1.53332.2.3.40 | Scalarf3OverlAl_2 | read-only | current | Locked motor 3 |
| 1.3.6.1.4.1.53332.2.3.41 | Scalarf3LowDCAl_2 | read-only | current | Low DC 3 |
| 1.3.6.1.4.1.53332.2.3.42 | Scalarf4GeneralAl_2 | read-only | current | Fan general alarm 4 |
| 1.3.6.1.4.1.53332.2.3.43 | Scalarf4PowerAl_2 | read-only | current | Phase failure/undervolt.4 |
| 1.3.6.1.4.1.53332.2.3.44 | Scalarf4CommAl_2 | read-only | current | Communication 4 |
| 1.3.6.1.4.1.53332.2.3.45 | Scalarf4HiTempAl_2 | read-only | current | Power mod overheated 4 |
| 1.3.6.1.4.1.53332.2.3.46 | Scalarf4NetComAl_2 | read-only | current | Master/Slave com. 4 |
| 1.3.6.1.4.1.53332.2.3.47 | Scalarf4InvRegAl_2 | read-only | current | Regulation module 4 |
| 1.3.6.1.4.1.53332.2.3.48 | Scalarf4HiMotTAl_2 | read-only | current | Motor overheated 4 |
| 1.3.6.1.4.1.53332.2.3.49 | Scalarf4HallSenAl_2 | read-only | current | Hall sensor error 4 |
| 1.3.6.1.4.1.53332.2.3.50 | Scalarf4OverlAl_2 | read-only | current | Locked motor 4 |
| 1.3.6.1.4.1.53332.2.3.51 | Scalarf4LowDCAl_2 | read-only | current | Low DC 4 |
| 1.3.6.1.4.1.53332.2.3.52 | Scalarf5GeneralAl_2 | read-only | current | Fan general alarm 5 |
| 1.3.6.1.4.1.53332.2.3.53 | Scalarf5PowerAl_2 | read-only | current | Phase failure/undervolt.5 |
| 1.3.6.1.4.1.53332.2.3.54 | Scalarf5CommAl_2 | read-only | current | Communication 5 |
| 1.3.6.1.4.1.53332.2.3.55 | Scalarf5HiTempAl_2 | read-only | current | Power mod overheated 5 |
| 1.3.6.1.4.1.53332.2.3.56 | Scalarf5NetComAl_2 | read-only | current | Master/Slave com. 5 |
| 1.3.6.1.4.1.53332.2.3.57 | Scalarf5InvRegAl_2 | read-only | current | Regulation module 5 |
| 1.3.6.1.4.1.53332.2.3.58 | Scalarf5HiMotTAl_2 | read-only | current | Motor overheated 5 |
| 1.3.6.1.4.1.53332.2.3.59 | Scalarf5HallSenAl_2 | read-only | current | Hall sensor error 5 |
| 1.3.6.1.4.1.53332.2.3.60 | Scalarf5OverlAl_2 | read-only | current | Locked motor 5 |
| 1.3.6.1.4.1.53332.2.3.61 | Scalarf5LowDCAl_2 | read-only | current | Low DC 5 |
| 1.3.6.1.4.1.53332.2.3.62 | Scalarf6GeneralAl_2 | read-only | current | Fan general alarm 6 |
| 1.3.6.1.4.1.53332.2.3.63 | Scalarf6PowerAl_2 | read-only | current | Phase failure/undervolt.6 |
| 1.3.6.1.4.1.53332.2.3.64 | Scalarf6CommAl_2 | read-only | current | Communication 6 |
| 1.3.6.1.4.1.53332.2.3.65 | Scalarf6HiTempAl_2 | read-only | current | Power mod overheated 6 |
| 1.3.6.1.4.1.53332.2.3.66 | Scalarf6NetComAl_2 | read-only | current | Master/Slave com. 6 |
| 1.3.6.1.4.1.53332.2.3.67 | Scalarf6InvRegAl_2 | read-only | current | Regulation module 6 |
| 1.3.6.1.4.1.53332.2.3.68 | Scalarf6HiMotTAl_2 | read-only | current | Motor overheated 6 |
| 1.3.6.1.4.1.53332.2.3.69 | Scalarf6HallSenAl_2 | read-only | current | Hall sensor error 6 |
| 1.3.6.1.4.1.53332.2.3.70 | Scalarf6OverlAl_2 | read-only | current | Locked motor 6 |
| 1.3.6.1.4.1.53332.2.3.71 | Scalarf6LowDCAl_2 | read-only | current | Low DC 6 |
| 1.3.6.1.4.1.53332.2.3.72 | Scalarf7GeneralAl_2 | read-only | current | Fan general alarm 7 |
| 1.3.6.1.4.1.53332.2.3.73 | Scalarf7PowerAl_2 | read-only | current | Phase failure/undervolt.7 |
| 1.3.6.1.4.1.53332.2.3.74 | Scalarf7CommAl_2 | read-only | current | Communication 7 |
| 1.3.6.1.4.1.53332.2.3.75 | Scalarf7HiTempAl_2 | read-only | current | Power mod overheated 7 |
| 1.3.6.1.4.1.53332.2.3.76 | Scalarf7NetComAl_2 | read-only | current | Master/Slave com. 7 |
| 1.3.6.1.4.1.53332.2.3.77 | Scalarf7InvRegAl_2 | read-only | current | Regulation module 7 |
| 1.3.6.1.4.1.53332.2.3.78 | Scalarf7HiMotTAl_2 | read-only | current | Motor overheated 7 |
| 1.3.6.1.4.1.53332.2.3.79 | Scalarf7HallSenAl_2 | read-only | current | Hall sensor error 7 |
| 1.3.6.1.4.1.53332.2.3.80 | Scalarf7OverlAl_2 | read-only | current | Locked motor 7 |
| 1.3.6.1.4.1.53332.2.3.81 | Scalarf7LowDCAl_2 | read-only | current | Low DC 7 |
| 1.3.6.1.4.1.53332.2.3.82 | Scalarf8GeneralAl_2 | read-only | current | Fan general alarm 8 |
| 1.3.6.1.4.1.53332.2.3.83 | Scalarf8PowerAl_2 | read-only | current | Phase failure/undervolt.8 |
| 1.3.6.1.4.1.53332.2.3.84 | Scalarf8CommAl_2 | read-only | current | Communication 8 |
| 1.3.6.1.4.1.53332.2.3.85 | Scalarf8HiTempAl_2 | read-only | current | Power mod overheated 8 |
| 1.3.6.1.4.1.53332.2.3.86 | Scalarf8NetComAl_2 | read-only | current | Master/Slave com. 8 |
| 1.3.6.1.4.1.53332.2.3.87 | Scalarf8InvRegAl_2 | read-only | current | Regulation module 8 |
| 1.3.6.1.4.1.53332.2.3.88 | Scalarf8HiMotTAl_2 | read-only | current | Motor overheated 8 |
| 1.3.6.1.4.1.53332.2.3.89 | Scalarf8HallSenAl_2 | read-only | current | Hall sensor error 8 |
| 1.3.6.1.4.1.53332.2.3.90 | Scalarf8OverlAl_2 | read-only | current | Locked motor 8 |
| 1.3.6.1.4.1.53332.2.3.91 | Scalarf8LowDCAl_2 | read-only | current | Low DC 8 |
| 1.3.6.1.4.1.53332.2.3.92 | Scalarf9GeneralAl_2 | read-only | current | Fan general alarm 9 |
| 1.3.6.1.4.1.53332.2.3.93 | Scalarf9PowerAl_2 | read-only | current | Phase failure/undervolt.9 |
| 1.3.6.1.4.1.53332.2.3.94 | Scalarf9CommAl_2 | read-only | current | Communication 9 |
| 1.3.6.1.4.1.53332.2.3.95 | Scalarf9HiTempAl_2 | read-only | current | Power mod overheated 9 |
| 1.3.6.1.4.1.53332.2.3.96 | Scalarf9NetComAl_2 | read-only | current | Master/Slave com. 9 |
| 1.3.6.1.4.1.53332.2.3.97 | Scalarf9InvRegAl_2 | read-only | current | Regulation module 9 |
| 1.3.6.1.4.1.53332.2.3.98 | Scalarf9HiMotTAl_2 | read-only | current | Motor overheated 9 |
| 1.3.6.1.4.1.53332.2.3.99 | Scalarf9HallSenAl_2 | read-only | current | Hall sensor error 9 |
| 1.3.6.1.4.1.53332.2.3.100 | Scalarf9OverlAl_2 | read-only | current | Locked motor 9 |
| 1.3.6.1.4.1.53332.2.3.101 | Scalarf9LowDCAl_2 | read-only | current | Low DC 9 |
| 1.3.6.1.4.1.53332.2.3.102 | Scalarf10GenlAl_2 | read-only | current | Fan general alarm 10 |
| 1.3.6.1.4.1.53332.2.3.103 | Scalarf10PowerAl_2 | read-only | current | Phase failure/undervolt.10 |
| 1.3.6.1.4.1.53332.2.3.104 | Scalarf10CommAl_2 | read-only | current | Communication 10 |
| 1.3.6.1.4.1.53332.2.3.105 | Scalarf10HiTempAl_2 | read-only | current | Power mod overheated 10 |
| 1.3.6.1.4.1.53332.2.3.106 | Scalarf10NetComAl_2 | read-only | current | Master/Slave com. 10 |
| 1.3.6.1.4.1.53332.2.3.107 | Scalarf10InvRegAl_2 | read-only | current | Regulation module 10 |
| 1.3.6.1.4.1.53332.2.3.108 | Scalarf10HiMotTAl_2 | read-only | current | Motor overheated 10 |
| 1.3.6.1.4.1.53332.2.3.109 | Scalarf10HallSAl_2 | read-only | current | Hall sensor error 10 |
| 1.3.6.1.4.1.53332.2.3.110 | Scalarf10OverlAl_2 | read-only | current | Locked motor 10 |
| 1.3.6.1.4.1.53332.2.3.111 | Scalarf10LowDCAl_2 | read-only | current | Low DC 10 |
| 1.3.6.1.4.1.53332.2.3.112 | ScalarretTempPbAl_2 | read-only | current | Return temperature probe |
| 1.3.6.1.4.1.53332.2.3.113 | ScalarsupTempPrAl_2 | read-only | current | Supply temperature probe |
| 1.3.6.1.4.1.53332.2.3.114 | ScalarretHumPrAl_2 | read-only | current | Return humidity probe |
| 1.3.6.1.4.1.53332.2.3.115 | ScalarsupHumPrAl_2 | read-only | current | Supply humidity probe |
| 1.3.6.1.4.1.53332.2.3.116 | ScalarairPrSensAl_2 | read-only | current | Air diff.pressure probe |
| 1.3.6.1.4.1.53332.2.3.117 | ScalarwatIN1PrAl_2 | read-only | current | Water temp. IN1 probe |
| 1.3.6.1.4.1.53332.2.3.118 | ScalarwatOUT1PrAl_2 | read-only | current | Water temp. OUT1 probe |
| 1.3.6.1.4.1.53332.2.3.119 | ScalarwatIN2PrAl_2 | read-only | current | Water temp. IN2 probe |
| 1.3.6.1.4.1.53332.2.3.120 | ScalarwatOUT2PrAl_2 | read-only | current | Water temp. OUT2 probe |
| 1.3.6.1.4.1.53332.2.3.121 | ScalarwatFlw1PrAl_2 | read-only | current | Water flow1/T.liquid1 pr. |
| 1.3.6.1.4.1.53332.2.3.122 | ScalarwatFlw2PrAl_2 | read-only | current | Water flow2/T.liquid2 pr. |
| 1.3.6.1.4.1.53332.2.3.123 | ScalardFPSGenAl_2 | read-only | current | Filter diff.press. probe |
| 1.3.6.1.4.1.53332.2.3.124 | ScalardFPSBrokAl_2 | read-only | current | Breakdown alarm |
| 1.3.6.1.4.1.53332.2.3.125 | ScalardFPSCablAl_2 | read-only | current | Wiring alarm |
| 1.3.6.1.4.1.53332.2.3.126 | ScalardFPSRangeAl_2 | read-only | current | Pressure range alarm |
| 1.3.6.1.4.1.53332.2.3.127 | ScalardFPSADCAl_2 | read-only | current | ADC overload alarm |
| 1.3.6.1.4.1.53332.2.3.128 | ScalardFPSSetAl_2 | read-only | current | Calibration alarm |
| 1.3.6.1.4.1.53332.2.3.129 | ScalardFPSDCOAl_2 | read-only | current | DCO alarm |
| 1.3.6.1.4.1.53332.2.3.130 | ScalardFPSWatdAl_2 | read-only | current | Watchdog alarm |
| 1.3.6.1.4.1.53332.2.3.131 | ScalardFPSCommAl_2 | read-only | current | Communication alarm |
| 1.3.6.1.4.1.53332.2.3.132 | ScalarinvC1GenAl_2 | read-only | current | DC inverter general alarm |
| 1.3.6.1.4.1.53332.2.3.133 | ScalarinvC1CommAl_2 | read-only | current | Inverter communication |
| 1.3.6.1.4.1.53332.2.3.134 | Scalarc1ThermAl_2 | read-only | current | C1 Thermal alarm |
| 1.3.6.1.4.1.53332.2.3.135 | Scalarc1HighPresAl_2 | read-only | current | C1 High pressure alarm |
| 1.3.6.1.4.1.53332.2.3.136 | Scalarc1LowPresAl_2 | read-only | current | C1 Low pressure alarm |
| 1.3.6.1.4.1.53332.2.3.137 | Scalarc1HighDiscAl_2 | read-only | current | C1 High discharge alarm |
| 1.3.6.1.4.1.53332.2.3.138 | Scalarc1LCompRatAl_2 | read-only | current | C1 low compresion alarm |
| 1.3.6.1.4.1.53332.2.3.139 | Scalarcondenser1Al_2 | read-only | current | Condenser 1 general alarm |
| 1.3.6.1.4.1.53332.2.3.140 | Scalarc1WatFlowAl_2 | read-only | current | Condenser 1 flow alarm |
| 1.3.6.1.4.1.53332.2.3.141 | ScalareEV1GenAl_2 | read-only | current | EEV1 general alarm |
| 1.3.6.1.4.1.53332.2.3.142 | ScalareEV1CommAl_2 | read-only | current | EEV1 communication alarm |
| 1.3.6.1.4.1.53332.2.3.143 | ScalareEV1SuctPrAl_2 | read-only | current | EEV1 suction temp. probe |
| 1.3.6.1.4.1.53332.2.3.144 | ScalareEV1EvapPrAl_2 | read-only | current | EEV1 evap. temp. probe |
| 1.3.6.1.4.1.53332.2.3.145 | ScalareEV1CondPrAl_2 | read-only | current | EEV1 condens. temp. probe |
| 1.3.6.1.4.1.53332.2.3.146 | ScalareEV1DiscPrAl_2 | read-only | current | EEV1 disch. temp. probe |
| 1.3.6.1.4.1.53332.2.3.147 | Scalarc2ThermAl_2 | read-only | current | C2 Thermal alarm |
| 1.3.6.1.4.1.53332.2.3.148 | Scalarc2HighPresAl_2 | read-only | current | C2 High pressure alarm |
| 1.3.6.1.4.1.53332.2.3.149 | Scalarc2LowPresAl_2 | read-only | current | C2 Low pressure alarm |
| 1.3.6.1.4.1.53332.2.3.150 | Scalarc2HighDiscAl_2 | read-only | current | C2 High discharge alarm |
| 1.3.6.1.4.1.53332.2.3.151 | Scalarc2LCompRatAl_2 | read-only | current | C2 low compresion alarm |
| 1.3.6.1.4.1.53332.2.3.152 | Scalarcondenser2Al_2 | read-only | current | Condenser 2 general alarm |
| 1.3.6.1.4.1.53332.2.3.153 | Scalarc2WatFlowAl_2 | read-only | current | Condenser 2 flow alarm |
| 1.3.6.1.4.1.53332.2.3.154 | ScalareEV2GenAl_2 | read-only | current | EEV2 general alarm |
| 1.3.6.1.4.1.53332.2.3.155 | ScalareEV2CommAl_2 | read-only | current | EEV2 communication alarm |
| 1.3.6.1.4.1.53332.2.3.156 | ScalareEV2SuctPrAl_2 | read-only | current | EEV2 suction temp. probe |
| 1.3.6.1.4.1.53332.2.3.157 | ScalareEV2EvapPrAl_2 | read-only | current | EEV2 evap. temp. probe |
| 1.3.6.1.4.1.53332.2.3.158 | ScalareEV2CondPrAl_2 | read-only | current | EEV2 condens. temp. probe |
| 1.3.6.1.4.1.53332.2.3.159 | ScalareEV2DiscPrAl_2 | read-only | current | EEV2 disch. temp. probe |
| 1.3.6.1.4.1.53332.2.3.160 | ScalarintHumGenAl_2 | read-only | current | Internal humidifier alarm |
| 1.3.6.1.4.1.53332.2.3.161 | ScalarcPYCommAl_2 | read-only | current | Communication alarm |
| 1.3.6.1.4.1.53332.2.3.162 | ScalarcPYMemoryAl_2 | read-only | current | Memory error alarm |
| 1.3.6.1.4.1.53332.2.3.163 | ScalarcPYParamAl_2 | read-only | current | Parameters error alarm |
| 1.3.6.1.4.1.53332.2.3.164 | ScalarcPYHighCurAl_2 | read-only | current | Electrodes high current |
| 1.3.6.1.4.1.53332.2.3.165 | ScalarcPYLoSteamAl_2 | read-only | current | Low steam product. alarm |
| 1.3.6.1.4.1.53332.2.3.166 | ScalarcPYDrainAl_2 | read-only | current | Drain loss alarm |
| 1.3.6.1.4.1.53332.2.3.167 | ScalarcPYMaintAl_2 | read-only | current | Maintenance hours alarm |
| 1.3.6.1.4.1.53332.2.3.168 | ScalarcPYNoWaterAl_2 | read-only | current | Water loss alarm |
| 1.3.6.1.4.1.53332.2.3.169 | ScalarcPYCylMainAl_2 | read-only | current | Cylinder mainten. alarm |
| 1.3.6.1.4.1.53332.2.3.170 | ScalarcPYDirtCylAl_2 | read-only | current | Exaust cylinder alarm |
| 1.3.6.1.4.1.53332.2.3.171 | ScalarcPYFoamAl_2 | read-only | current | Foam presence alarm |
| 1.3.6.1.4.1.53332.2.3.172 | ScalarcPYLifeTimAl_2 | read-only | current | Life time expired alarm |
| 1.3.6.1.4.1.53332.2.3.173 | ScalarcPYHiWLevAl_2 | read-only | current | High water level alarm |
| 1.3.6.1.4.1.53332.2.3.174 | ScalarcPYHWatConAl_2 | read-only | current | High conductivity alarm |
| 1.3.6.1.4.1.53332.2.3.175 | ScalarcPYConnAl_2 | read-only | current | Connection error alarm |
| 1.3.6.1.4.1.53332.2.3.176 | ScalarwatPresAl_2 | read-only | current | Water presence alarm |
| 1.3.6.1.4.1.53332.2.3.177 | ScalardrainPumpAl_2 | read-only | current | Drain pump alarm |
| 1.3.6.1.4.1.53332.2.3.178 | ScalarelHeatAl_2 | read-only | current | Electric heater alarm |
| 1.3.6.1.4.1.53332.2.3.179 | ScalarfilterAl_2 | read-only | current | Dirty filter alarm |
| 1.3.6.1.4.1.53332.2.3.180 | ScalardryCoolerAl_2 | read-only | current | Dry cooler alarm |
| 1.3.6.1.4.1.53332.2.3.181 | ScalarextHumidAl_2 | read-only | current | External humidifier alarm |
| 1.3.6.1.4.1.53332.2.3.182 | ScalarwaterPumpAl_2 | read-only | current | Water pump alarm |
| 1.3.6.1.4.1.53332.2.3.183 | ScalarcondUnitGAl_2 | read-only | current | Motocondenser alarm |
| 1.3.6.1.4.1.53332.2.3.184 | ScalargasLeakAl_2 | read-only | current | Refrigerant leak alarm |
| 1.3.6.1.4.1.53332.2.3.185 | ScalarpowerSuppAl_2 | read-only | current | Power fault alarm |
| 1.3.6.1.4.1.53332.2.3.186 | ScalargenSoftAl_2 | read-only | current | Not critical generic al. |
| 1.3.6.1.4.1.53332.2.3.187 | ScalarlocalNetAl_2 | read-only | current | Local network alarm |
| 1.3.6.1.4.1.53332.2.3.188 | ScalarregHiTempAl_2 | read-only | current | High regulation T.alarm |
| 1.3.6.1.4.1.53332.2.3.189 | ScalarregLowTempAl_2 | read-only | current | Low regulation T.alarm |
| 1.3.6.1.4.1.53332.2.3.190 | ScalarhiLimTempAl_2 | read-only | current | High limit temp. alarm |
| 1.3.6.1.4.1.53332.2.3.191 | ScalarlowLimTempAl_2 | read-only | current | Low limit temp. alarm |
| 1.3.6.1.4.1.53332.2.3.192 | ScalarretHiHumiAl_2 | read-only | current | High room humidity alarm |
| 1.3.6.1.4.1.53332.2.3.193 | ScalarretLowHumiAl_2 | read-only | current | Low room humidity alarm |
| 1.3.6.1.4.1.53332.2.3.194 | ScalarsupHiHumiAl_2 | read-only | current | High supp.humidity alarm |
| 1.3.6.1.4.1.53332.2.3.195 | ScalarsupLowHumiAl_2 | read-only | current | Low supp.humidity alarm |
| 1.3.6.1.4.1.53332.2.3.196 | ScalarprobeMod1COM_2 | read-only | current | Module 1 communication |
| 1.3.6.1.4.1.53332.2.3.197 | ScalarprMod1err1_2 | read-only | current | Module 1 probe 1 alarm |
| 1.3.6.1.4.1.53332.2.3.198 | ScalarprMod1err2_2 | read-only | current | Module 1 probe 2 alarm |
| 1.3.6.1.4.1.53332.2.3.199 | ScalarprMod1err3_2 | read-only | current | Module 1 probe 3 alarm |
| 1.3.6.1.4.1.53332.2.3.200 | ScalarprMod1err4_2 | read-only | current | Module 1 probe 4 alarm |
| 1.3.6.1.4.1.53332.2.3.201 | ScalarprMod1err5_2 | read-only | current | Module 1 probe 5 alarm |
| 1.3.6.1.4.1.53332.2.3.202 | ScalarprMod1err6_2 | read-only | current | Module 1 probe 6 alarm |
| 1.3.6.1.4.1.53332.2.3.203 | ScalarprobeMod2COM_2 | read-only | current | Module 2 communication |
| 1.3.6.1.4.1.53332.2.3.204 | ScalarprMod2err1_2 | read-only | current | Module 2 probe 1 alarm |
| 1.3.6.1.4.1.53332.2.3.205 | ScalarprMod2err2_2 | read-only | current | Module 2 probe 2 alarm |
| 1.3.6.1.4.1.53332.2.3.206 | ScalarprMod2err3_2 | read-only | current | Module 2 probe 3 alarm |
| 1.3.6.1.4.1.53332.2.3.207 | ScalarprMod2err4_2 | read-only | current | Module 2 probe 4 alarm |
| 1.3.6.1.4.1.53332.2.3.208 | ScalarprMod2err5_2 | read-only | current | Module 2 probe 5 alarm |
| 1.3.6.1.4.1.53332.2.3.209 | ScalarprMod2err6_2 | read-only | current | Module 2 probe 6 alarm |
| 1.3.6.1.4.1.53332.2.3.210 | ScalarprobeMod3COM_2 | read-only | current | Module 3 communication |
| 1.3.6.1.4.1.53332.2.3.211 | ScalarprMod3err1_2 | read-only | current | Module 3 probe 1 alarm |
| 1.3.6.1.4.1.53332.2.3.212 | ScalarprMod3err2_2 | read-only | current | Module 3 probe 2 alarm |
| 1.3.6.1.4.1.53332.2.3.213 | ScalarprMod3err3_2 | read-only | current | Module 3 probe 3 alarm |
| 1.3.6.1.4.1.53332.2.3.214 | ScalarprMod3err4_2 | read-only | current | Module 3 probe 4 alarm |
| 1.3.6.1.4.1.53332.2.3.215 | ScalarprMod3err5_2 | read-only | current | Module 3 probe 5 alarm |
| 1.3.6.1.4.1.53332.2.3.216 | ScalarprMod3err6_2 | read-only | current | Module 3 probe 6 alarm |