MIB Viewer

SOCOMECUPS7-MIB

255 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.4555Nodesocomec
1.3.6.1.4.1.4555.1Nodesoftware
1.3.6.1.4.1.4555.1.1Nodenetwork
1.3.6.1.4.1.4555.1.1.7Nodenetvision7
1.3.6.1.4.1.4555.1.1.7.1NodeupsObjects
1.3.6.1.4.1.4555.1.1.7.1.1NodeupsIdent
1.3.6.1.4.1.4555.1.1.7.1.1.1ScalarupsIdentModelread-onlymandatoryThe UPS Model designation.
1.3.6.1.4.1.4555.1.1.7.1.1.2ScalarupsIdentSerialNumberread-onlymandatoryThe UPS Serial number.
1.3.6.1.4.1.4555.1.1.7.1.1.3ScalarupsIdentUserRefread-onlymandatoryThe UPS Reference.
1.3.6.1.4.1.4555.1.1.7.1.1.4ScalarupsIdentUserLocationread-onlymandatoryThe UPS Location.
1.3.6.1.4.1.4555.1.1.7.1.1.5ScalarupsIdentAgentSoftwareVersionread-onlymandatoryThe UPS Net Vision software version.
1.3.6.1.4.1.4555.1.1.7.1.1.6ScalarupsSystemNameread-onlymandatoryThe UPS Net Vision system name.
1.3.6.1.4.1.4555.1.1.7.1.1.7ScalarupsSystemContactread-onlymandatoryThe UPS Net Vision system contact.
1.3.6.1.4.1.4555.1.1.7.1.1.8ScalarupsSystemLocationread-onlymandatoryThe UPS Net Vision system location.
1.3.6.1.4.1.4555.1.1.7.1.2NodeupsBattery
1.3.6.1.4.1.4555.1.1.7.1.2.1ScalarupsBatteryStatusread-onlymandatoryThe present battery status
1.3.6.1.4.1.4555.1.1.7.1.2.2ScalarupsSecondsOnBatteryread-onlymandatoryIf the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last res…
1.3.6.1.4.1.4555.1.1.7.1.2.3ScalarupsEstimatedMinutesRemainingread-onlymandatoryAn estimate of the time to battery charge depletion under the present load conditions. Compute when UPS is on battery power
1.3.6.1.4.1.4555.1.1.7.1.2.4ScalarupsEstimatedChargeRemainingread-onlymandatoryAn estimate of the battery charge remaining expressed as a percent of full charge.
1.3.6.1.4.1.4555.1.1.7.1.2.5ScalarupsBatteryVoltageread-onlymandatoryThe magnitude of the present battery voltage in 0.1 Volt DC.
1.3.6.1.4.1.4555.1.1.7.1.2.6ScalarupsBatteryTemperatureread-onlymandatoryThe ambient temperature at or near the UPS Battery casing in 0.1 degree
1.3.6.1.4.1.4555.1.1.7.1.2.7ScalarupsAmbientTemperatureread-onlymandatoryThe ambient temperature inside the UPS in 0.1 degree
1.3.6.1.4.1.4555.1.1.7.1.2.8ScalarupsBatteryCurrentread-onlymandatoryThe battry current in 0.1 Amp
1.3.6.1.4.1.4555.1.1.7.1.2.9ScalarupsBatterySOCread-onlymandatoryThe battry SOC
1.3.6.1.4.1.4555.1.1.7.1.3NodeupsInput
1.3.6.1.4.1.4555.1.1.7.1.3.1ScalarupsInputNumLinesread-onlymandatoryThe number of input lines utilized in this device. This variable indicates the number of rows in the input table.
1.3.6.1.4.1.4555.1.1.7.1.3.2ScalarupsInputFrequencyread-onlymandatoryThe current input frequency to the UPS system in 0.1 HZ.
1.3.6.1.4.1.4555.1.1.7.1.3.3TableupsInputTablenot-accessiblemandatoryA list of input table entries. The number of entries is given by the value of upsInputNumLines.
1.3.6.1.4.1.4555.1.1.7.1.3.3.1RowupsInputEntrynot-accessiblemandatoryAn entry containing information applicable to a particular input line.
1.3.6.1.4.1.4555.1.1.7.1.3.3.1.1ColumnupsInputLineIndexread-onlymandatory
1.3.6.1.4.1.4555.1.1.7.1.3.3.1.2ColumnupsInputVoltageread-onlymandatoryThe input utility line voltage in 0.1 volts.
1.3.6.1.4.1.4555.1.1.7.1.3.3.1.3ColumnupsInputCurrentread-onlymandatoryThe magnitude of the present input current in 0.1 A.
1.3.6.1.4.1.4555.1.1.7.1.3.3.1.4ColumnupsInputVoltageMaxread-onlymandatoryThe maximum utility line voltage in 0.1 VAC for last 1 minute.
1.3.6.1.4.1.4555.1.1.7.1.3.3.1.5ColumnupsInputVoltageMinread-onlymandatoryThe minimum utility line voltage in 0.1 VAC for last 1 minute.
1.3.6.1.4.1.4555.1.1.7.1.4NodeupsOutput
1.3.6.1.4.1.4555.1.1.7.1.4.1ScalarupsOutputSourceread-onlymandatoryThe present source of output power.
1.3.6.1.4.1.4555.1.1.7.1.4.2ScalarupsOutputFrequencyread-onlymandatoryThe current output frequency of the UPS system in 0.1 of HZ.
1.3.6.1.4.1.4555.1.1.7.1.4.3ScalarupsOutputNumLinesread-onlymandatoryThe number of output lines utilized in this device. This variable indicates the number of rows in the output table.
1.3.6.1.4.1.4555.1.1.7.1.4.4TableupsOutputTablenot-accessiblemandatoryA list of output table entries. The number of entries is given by the value of upsOutputNumLines.
1.3.6.1.4.1.4555.1.1.7.1.4.4.1RowupsOutputEntrynot-accessiblemandatoryAn entry containing information applicable to a particular output line.
1.3.6.1.4.1.4555.1.1.7.1.4.4.1.1ColumnupsOutputLineIndexread-onlymandatoryThe output line identifier.
1.3.6.1.4.1.4555.1.1.7.1.4.4.1.2ColumnupsOutputVoltageread-onlymandatoryThe output voltage of the UPS system in 0.1 volts.
1.3.6.1.4.1.4555.1.1.7.1.4.4.1.3ColumnupsOutputCurrentread-onlymandatoryThe output current of the UPS system in 0.1 Amps.
1.3.6.1.4.1.4555.1.1.7.1.4.4.1.4ColumnupsOutputPercentLoadread-onlymandatoryThe percentage of the UPS power capacity presently being used on this output line
1.3.6.1.4.1.4555.1.1.7.1.4.4.1.5ColumnupsOutputKvaread-onlymandatoryOutput apparent power of the UPS in 0.1 kVA.
1.3.6.1.4.1.4555.1.1.7.1.4.4.1.6ColumnupsOutputKwread-onlymandatoryOutput apparent power of the UPS in 0.1 kW.
1.3.6.1.4.1.4555.1.1.7.1.4.5ScalarupsOutputGlobalkVAread-onlymandatoryOutput global apparent power of the UPS in 0.1 kVA.
1.3.6.1.4.1.4555.1.1.7.1.4.6ScalarupsOutputGlobalkWread-onlymandatoryOutput global apparent power of the UPS in 0.1 kW.
1.3.6.1.4.1.4555.1.1.7.1.4.7ScalarupsOutputLoadRateread-onlymandatoryOutput global Load Rate.
1.3.6.1.4.1.4555.1.1.7.1.5NodeupsBypass
1.3.6.1.4.1.4555.1.1.7.1.5.1ScalarupsBypassFrequencyread-onlymandatoryThe present bypass frequency in 0.1 Hz.
1.3.6.1.4.1.4555.1.1.7.1.5.2ScalarupsBypassNumLinesread-onlymandatoryThe number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table.
1.3.6.1.4.1.4555.1.1.7.1.5.3TableupsBypassTablenot-accessiblemandatoryA list of bypass table entries. The number of entries is given by the value of upsBypassNumLines.
1.3.6.1.4.1.4555.1.1.7.1.5.3.1RowupsBypassEntrynot-accessiblemandatoryAn entry containing information applicable to a particular bypass input.
1.3.6.1.4.1.4555.1.1.7.1.5.3.1.1ColumnupsBypassLineIndexread-onlymandatoryThe bypass line identifier.
1.3.6.1.4.1.4555.1.1.7.1.5.3.1.2ColumnupsBypassVoltageread-onlymandatoryThe present bypass voltage of the UPS system in 0.1 volts.
1.3.6.1.4.1.4555.1.1.7.1.5.3.1.3ColumnupsBypassCurrentread-onlymandatoryThe present bypass current of the UPS system in 0.1 Amps.
1.3.6.1.4.1.4555.1.1.7.1.6NodeupsAlarm
1.3.6.1.4.1.4555.1.1.7.1.6.1ScalarupsAlarmsPresentread-onlymandatoryThe present number of active alarm conditions.
1.3.6.1.4.1.4555.1.1.7.1.6.2TableupsAlarmTablenot-accessiblemandatoryA list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is …
1.3.6.1.4.1.4555.1.1.7.1.6.2.1RowupsAlarmEntrynot-accessiblemandatoryAn entry containing information applicable to a particular alarm.
1.3.6.1.4.1.4555.1.1.7.1.6.2.1.1ColumnupsAlarmIdread-onlymandatoryA unique identifier for an alarm condition. This value must remain constant.
1.3.6.1.4.1.4555.1.1.7.1.6.2.1.2ColumnupsAlarmDescrread-onlymandatoryA reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm con…
1.3.6.1.4.1.4555.1.1.7.1.6.2.1.3ColumnupsAlarmTimeread-onlymandatoryThe value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before ag…
1.3.6.1.4.1.4555.1.1.7.1.6.2.1.4ColumnupsAlarmExtDesread-onlymandatoryExtra description.
1.3.6.1.4.1.4555.1.1.7.1.6.3NodeupsWellKnownAlarms
1.3.6.1.4.1.4555.1.1.7.1.6.3.1ScalarupsAlarmImminentStopread-onlymandatoryUPS in imminent stop. Load will switch off. (A000)
1.3.6.1.4.1.4555.1.1.7.1.6.3.2ScalarupsAlarmOverloadread-onlymandatoryThe output load exceeds the UPS output capacity. (A001)
1.3.6.1.4.1.4555.1.1.7.1.6.3.3ScalarupsAlarmTemperatureread-onlymandatoryUPS temperature is out of tolerance. (A002)
1.3.6.1.4.1.4555.1.1.7.1.6.3.4ScalarupsAlarmTransferLockread-onlymandatoryAutomatic and manual transfer are locked. (A003)
1.3.6.1.4.1.4555.1.1.7.1.6.3.5ScalarupsAlarmAutoTransferImpossibleread-onlymandatoryAutomatic transfer is disabled. Inverter and bypass sources are not synchronized (A004)
1.3.6.1.4.1.4555.1.1.7.1.6.3.6ScalarupsAlarmInsufficientResourcesread-onlymandatoryInsufficient resources alarm. The load cannot by supplied by alternate source (A005)
1.3.6.1.4.1.4555.1.1.7.1.6.3.7ScalarupsAlarmRedundancyLostread-onlymandatoryRedundancy lost alarm. (A006)
1.3.6.1.4.1.4555.1.1.7.1.6.3.8ScalarupsAlarmOutputShortCircuitread-onlymandatoryAn output short-circuit has been detected by UPS. (A007)
1.3.6.1.4.1.4555.1.1.7.1.6.3.9ScalarupsAlarmMaintenanceread-onlymandatoryThe UPS requests a maintenance service check. (A012)
1.3.6.1.4.1.4555.1.1.7.1.6.3.10ScalarupsAlarmRemoteServiceread-onlymandatoryThe UPS requests a remote service action. (A013)
1.3.6.1.4.1.4555.1.1.7.1.6.3.11ScalarupsAlarmGeneralFaultread-onlymandatoryA general fault in the UPS has been detected. One of UPS alarm is present. (A015)
1.3.6.1.4.1.4555.1.1.7.1.6.3.12ScalarupsAlarmBatteryCircuitOpenread-onlymandatoryBattery circuit open. Battery breaker or fuse open. (A016)
1.3.6.1.4.1.4555.1.1.7.1.6.3.13ScalarupsAlarmBatteryDischargedread-onlymandatoryThe UPS will be unable to sustain the present load when and if the utility power is lost. The Battery is discharched. (A017)
1.3.6.1.4.1.4555.1.1.7.1.6.3.14ScalarupsAlarmLowBatteryread-onlymandatoryThe remaining battery run-time is less than or equal to battery low threshold. (A018)
1.3.6.1.4.1.4555.1.1.7.1.6.3.15ScalarupsAlarmOnBatteryread-onlymandatoryThe UPS is drawing power from the batteries. (A019)
1.3.6.1.4.1.4555.1.1.7.1.6.3.16ScalarupsAlarmBatteryTemperatureread-onlymandatoryBattery Temperature Alarm. (A020)
1.3.6.1.4.1.4555.1.1.7.1.6.3.17ScalarupsAlarmBatteryRoomread-onlymandatoryAn external alarm has been detected in the Battery room. This alarm depends on external sensor: gaz, temperature, humidity or dry-contact. (A021)
1.3.6.1.4.1.4555.1.1.7.1.6.3.18ScalarupsAlarmBatteryTestread-onlymandatoryThe battery has been detected as weak during the test. (A022)
1.3.6.1.4.1.4555.1.1.7.1.6.3.19ScalarupsAlarmBatteryFaultread-onlymandatoryOne or more batteries have been determined to require replacement. (A027)
1.3.6.1.4.1.4555.1.1.7.1.6.3.20ScalarupsAlarmRectifierFaultread-onlymandatoryRectifier Critical alarm. (A032)
1.3.6.1.4.1.4555.1.1.7.1.6.3.21ScalarupsAlarmRectifierAlarmread-onlymandatoryRectifier Preventive alarm. (A033)
1.3.6.1.4.1.4555.1.1.7.1.6.3.22ScalarupsAlarmRecInputBadread-onlymandatoryrectifier Input power supply is out of tolerance or absent. (A035)
1.3.6.1.4.1.4555.1.1.7.1.6.3.23ScalarupsAlarmGenSetGeneralread-onlymandatoryGen-set general alarm. coming from external dry-contact. (A036)
1.3.6.1.4.1.4555.1.1.7.1.6.3.24ScalarupsAlarmBatteryChargerFaultread-onlymandatoryBattery charger Critical Alarm. (A037)
1.3.6.1.4.1.4555.1.1.7.1.6.3.25ScalarupsAlarmBatteryChargerAlarmread-onlymandatoryBattery charger Preventive Alarm. (A038)
1.3.6.1.4.1.4555.1.1.7.1.6.3.26ScalarupsAlarmInverterFaultread-onlymandatoryInverter Critical alarm. (A040)
1.3.6.1.4.1.4555.1.1.7.1.6.3.27ScalarupsAlarmInverterAlarmread-onlymandatoryInverter preventive alarm. (A041)
1.3.6.1.4.1.4555.1.1.7.1.6.3.28ScalarupsAlarmBypassFaultread-onlymandatoryInverter Critical alarm. (A048)
1.3.6.1.4.1.4555.1.1.7.1.6.3.29ScalarupsAlarmBypassAlarmread-onlymandatoryInverter preventive alarm. (A049)
1.3.6.1.4.1.4555.1.1.7.1.6.3.30ScalarupsAlarmBypInputBadread-onlymandatoryBypass Input power supply is out of tolerance or absent. (A050)
1.3.6.1.4.1.4555.1.1.7.1.6.3.31ScalarupsAlarmPhaseRotationFaultread-onlymandatoryPhase rotation fault. (A051)
1.3.6.1.4.1.4555.1.1.7.1.6.3.32ScalarupsAlarmFansFailureread-onlymandatoryFans failure. (A054)
1.3.6.1.4.1.4555.1.1.7.1.6.3.33ScalarupsAlarmMaintenanceBypassread-onlymandatoryMaintenance bypass alarm. Output breaker and manual bypass breaker closed together. (A056)
1.3.6.1.4.1.4555.1.1.7.1.6.3.34ScalarupsAlarmUPSPowerOffActiveread-onlymandatoryUPS power off has been activated by external device. (A059)
1.3.6.1.4.1.4555.1.1.7.1.6.3.35ScalarupsAlarmWrongConfigurationread-onlymandatoryConfiguration data map corrupted, or wrong configuration. (A060)
1.3.6.1.4.1.4555.1.1.7.1.6.3.36ScalarupsAlarmInternalFailureread-onlymandatoryInternal failure, or internal communication failure. (A061)
1.3.6.1.4.1.4555.1.1.7.1.6.3.37ScalarupsAlarmOptionalBoardsread-onlymandatoryOptional boards alarm. Board not present or wrong configuration (A062)
1.3.6.1.4.1.4555.1.1.7.1.6.3.38ScalarupsAlarmExternalAlarm1read-onlymandatoryExternal Alarm 1. Coming from ADC Card: Input set as alarm (A064)
1.3.6.1.4.1.4555.1.1.7.1.6.3.39ScalarupsAlarmExternalAlarm2read-onlymandatoryExternal Alarm 2. Coming from ADC Card: Input set as alarm (A065)
1.3.6.1.4.1.4555.1.1.7.1.6.3.40ScalarupsAlarmExternalAlarm3read-onlymandatoryExternal Alarm 3. Coming from ADC Card: Input set as alarm (A066)
1.3.6.1.4.1.4555.1.1.7.1.6.3.41ScalarupsAlarmExternalAlarm4read-onlymandatoryExternal Alarm 4. Coming from ADC Card: Input set as alarm (A067)
1.3.6.1.4.1.4555.1.1.7.1.6.3.42ScalarupsAlarmModule1Alarmread-onlymandatoryUnit or Module 1 in parallel general alarm.
1.3.6.1.4.1.4555.1.1.7.1.6.3.43ScalarupsAlarmModule2Alarmread-onlymandatoryUnit or Module 2 in parallel general alarm.
1.3.6.1.4.1.4555.1.1.7.1.6.3.44ScalarupsAlarmModule3Alarmread-onlymandatoryUnit or Module 3 in parallel general alarm.
1.3.6.1.4.1.4555.1.1.7.1.6.3.45ScalarupsAlarmModule4Alarmread-onlymandatoryUnit or Module 4 in parallel general alarm.
1.3.6.1.4.1.4555.1.1.7.1.6.3.46ScalarupsAlarmModule5Alarmread-onlymandatoryUnit or Module 5 in parallel general alarm.
1.3.6.1.4.1.4555.1.1.7.1.6.3.47ScalarupsAlarmModule6Alarmread-onlymandatoryUnit or Module 6 in parallel general alarm.
1.3.6.1.4.1.4555.1.1.7.1.6.3.48ScalarupsAlarmModule7Alarmread-onlymandatoryUnit or Module 7 in parallel general alarm.
1.3.6.1.4.1.4555.1.1.7.1.6.3.49ScalarupsAlarmModule8Alarmread-onlymandatoryUnit or Module 8 in parallel general alarm.
1.3.6.1.4.1.4555.1.1.7.1.6.3.50ScalarupsAlarmModule9Alarmread-onlymandatoryUnit or Module 9 in parallel general alarm.
1.3.6.1.4.1.4555.1.1.7.1.6.3.51ScalarupsAlarmModule10Alarmread-onlymandatoryUnit or Module 10 in parallel general alarm.
1.3.6.1.4.1.4555.1.1.7.1.6.3.52ScalarupsAlarmModule11Alarmread-onlymandatoryUnit or Module 11 in parallel general alarm.
1.3.6.1.4.1.4555.1.1.7.1.6.3.53ScalarupsAlarmModule12Alarmread-onlymandatoryUnit or Module 12 in parallel general alarm.
1.3.6.1.4.1.4555.1.1.7.1.6.3.54ScalarupsAlarmAutoTestRunningread-onlymandatoryThe UPS has launched the auto-test. (S030)
1.3.6.1.4.1.4555.1.1.7.1.6.3.55ScalarupsAlarmOnBypassread-onlymandatoryLoad supplied by automatic bypass. Load not protected.
1.3.6.1.4.1.4555.1.1.7.1.6.3.56ScalarupsAlarmUpsOutputOffread-onlymandatoryThe output of the UPS is in the off state. Load OFF or UPS on standby mode.
1.3.6.1.4.1.4555.1.1.7.1.6.3.57ScalarupsAlarmUpsSystemOffread-onlymandatoryThe UPS system is in the off state. Rectifier and Inverter are off.
1.3.6.1.4.1.4555.1.1.7.1.6.3.58ScalarupsAlarmCommunicationLostread-onlymandatoryThe communication with UPS has been lost.
1.3.6.1.4.1.4555.1.1.7.1.6.3.59ScalarupsAlarmShutdownPendingread-onlymandatoryThe condition to shutdown servers has been detected. The shutdown delay in underway.
1.3.6.1.4.1.4555.1.1.7.1.6.3.60ScalarupsAlarmShutdownRequesttread-onlymandatoryThe shutdown command has been sent to servers agent.
1.3.6.1.4.1.4555.1.1.7.1.6.3.61ScalarupsAlarmShutdownImminentread-onlymandatoryThe UPS will turn OFF, according the standby schedule settings.
1.3.6.1.4.1.4555.1.1.7.1.6.3.62ScalarupsAlarmAwaitingPowerread-onlymandatoryThe UPS output is in standby, and the UPS is awaiting the return of input power.
1.3.6.1.4.1.4555.1.1.7.1.7NodeupsControl
1.3.6.1.4.1.4555.1.1.7.1.7.1ScalarupsControlStatusControlread-writemandatoryThis object Control UPS status
1.3.6.1.4.1.4555.1.1.7.1.7.2ScalarupsShutdownDelayread-writemandatoryThis object set the delay time (in seconds) to turn UPS off after Net Vision broadcast shutdown request to connected clients
1.3.6.1.4.1.4555.1.1.7.1.7.3ScalarupsTurnOffAfterShutdownread-writemandatoryThis object enable/disable UPS turn off function after shutdown process complete
1.3.6.1.4.1.4555.1.1.7.1.7.4TableupsControlShutdownParamTablenot-accessiblemandatoryTable which describes the parameters for shutdown process when shutdown event occurs
1.3.6.1.4.1.4555.1.1.7.1.7.4.1RowshutdownParamEntrynot-accessiblemandatory
1.3.6.1.4.1.4555.1.1.7.1.7.4.1.1ColumnupsControlEventIndexread-onlymandatoryThe shutdown event identification
1.3.6.1.4.1.4555.1.1.7.1.7.4.1.2ColumnupsControlEventStatusread-writemandatoryStatus of the corresponding shutdown Event. When set to disable(), shutdown process will not start when corresponding event occurred.
1.3.6.1.4.1.4555.1.1.7.1.7.4.1.3ColumnupsControlDelayread-writemandatoryThe Delay after the occurrence of the corresponding shutdown event that Net Vision should issue shutdown request to connected clients. For WeeklyScheduledShutd…
1.3.6.1.4.1.4555.1.1.7.1.7.4.1.4ColumnupsControlFirstWarningread-writemandatoryThe delay after the occurrence of the corresponding shutdown event that the Net Vision will start sending the warning message to the connected clients. The val…
1.3.6.1.4.1.4555.1.1.7.1.7.4.1.5ColumnupsControlWarningIntervalread-writemandatoryThe frequency of sending warning messages to the connected clients when the corresponding shutdown event occurs. The value is in units of seconds.
1.3.6.1.4.1.4555.1.1.7.1.7.5TableupsControlWeeklyScheduleTablenot-accessiblemandatoryThe table to schedule shutting down the ups by weekly.
1.3.6.1.4.1.4555.1.1.7.1.7.5.1RowupsControlWeeklyScheduleEntrynot-accessiblemandatoryThe entries for each day.
1.3.6.1.4.1.4555.1.1.7.1.7.5.1.1ColumnupsControlWeeklyIndexread-onlymandatoryThe index of scheduled events.
1.3.6.1.4.1.4555.1.1.7.1.7.5.1.2ColumnupsControlWeeklyShutdownDayread-writemandatoryThe weekday on which the UPS should shut down.
1.3.6.1.4.1.4555.1.1.7.1.7.5.1.3ColumnupsControlWeeklyShutdownTimeread-writemandatoryThe time that the process of shutting down the UPS will be initiated in hh:mm format.
1.3.6.1.4.1.4555.1.1.7.1.7.5.1.4ColumnupsControlWeeklyRestartDayread-writemandatoryThe weekday on which the UPS should restart
1.3.6.1.4.1.4555.1.1.7.1.7.5.1.5ColumnupsControlWeeklyRestartTimeread-writemandatoryThe time the UPS will restart in hh:mm format.
1.3.6.1.4.1.4555.1.1.7.1.7.6TableupsControlSpecialScheduleTablenot-accessiblemandatoryThe table to schedule shutting down the ups.
1.3.6.1.4.1.4555.1.1.7.1.7.6.1RowupsControlSpecialScheduleEntrynot-accessiblemandatoryThe entries for each day.
1.3.6.1.4.1.4555.1.1.7.1.7.6.1.1ColumnupsControlSpecialIndexread-onlymandatoryThe index of scheduled events.
1.3.6.1.4.1.4555.1.1.7.1.7.6.1.2ColumnupsControlSpecialShutdownDayread-writemandatoryThe date on which the UPS should shut down in dd/mm/yyyy format.
1.3.6.1.4.1.4555.1.1.7.1.7.6.1.3ColumnupsControlSpecialShutdownTimeread-writemandatoryThe time that the process of shutting down the UPS will be initiated in hh:mm format
1.3.6.1.4.1.4555.1.1.7.1.7.6.1.4ColumnupsControlSpecialRestartDayread-writemandatoryThe date on which the UPS should restart in dd/mm/yyyy format
1.3.6.1.4.1.4555.1.1.7.1.7.6.1.5ColumnupsControlSpecialRestartTimeread-writemandatoryThe time the UPS will restart in hh:mm format.
1.3.6.1.4.1.4555.1.1.7.1.7.7TableupsControlEcoModeScheduleTablenot-accessiblemandatoryThe table to schedule enable/disable ups eco/mode by weekly.
1.3.6.1.4.1.4555.1.1.7.1.7.7.1RowupsControlEcoModeScheduleEntrynot-accessiblemandatoryThe entries for each day.
1.3.6.1.4.1.4555.1.1.7.1.7.7.1.1ColumnupsControlEcoModeIndexread-onlymandatoryThe index of scheduled events.
1.3.6.1.4.1.4555.1.1.7.1.7.7.1.2ColumnupsControlEcoModeStartDayread-writemandatoryThe weekday on which the UPS Eco/Mode should enable.
1.3.6.1.4.1.4555.1.1.7.1.7.7.1.3ColumnupsControlEcoModeStartTimeread-writemandatoryThe time that the UPS Eco/Mode will be enabled, in hh:mm format.
1.3.6.1.4.1.4555.1.1.7.1.7.7.1.4ColumnupsControlEcoModeEndDayread-writemandatoryThe weekday on which the UPS Eco/Mode should disable
1.3.6.1.4.1.4555.1.1.7.1.7.7.1.5ColumnupsControlEcoModeEndTimeread-writemandatoryThe time the UPS Eco/Mode will disabled, in hh:mm format.
1.3.6.1.4.1.4555.1.1.7.1.8NodeupsConfig
1.3.6.1.4.1.4555.1.1.7.1.8.1ScalarupsConfigNomKvaread-onlymandatoryUPS Nominal in 0.1 kVA
1.3.6.1.4.1.4555.1.1.7.1.8.2ScalarupsConfigNbrUnitread-onlymandatoryNumber of Units installed in the system
1.3.6.1.4.1.4555.1.1.7.1.8.3ScalarupsConfigUnitKvaread-onlymandatoryUNIT Nominal kVA
1.3.6.1.4.1.4555.1.1.7.1.8.4ScalarupsConfigRemoteCtrlread-onlymandatorySet to 1 if remote controls are enabled by UPS
1.3.6.1.4.1.4555.1.1.7.1.8.5TableupsDevicesTablenot-accessiblemandatoryThe devices powered by UPS and registered to NET VISION
1.3.6.1.4.1.4555.1.1.7.1.8.5.1RowupsDevicesEntrynot-accessiblemandatoryThe devices protected by NET VISION
1.3.6.1.4.1.4555.1.1.7.1.8.5.1.1ColumnindexOfDeviceread-onlymandatoryThe index of the device that is powered from UPS.
1.3.6.1.4.1.4555.1.1.7.1.8.5.1.2ColumnaddrOfDeviceread-onlymandatoryThe ip address of the device.
1.3.6.1.4.1.4555.1.1.7.1.8.5.1.3ColumnnameOfDeviceread-onlymandatoryThe name/description of the device powered from UPS.
1.3.6.1.4.1.4555.1.1.7.1.8.5.1.4ColumntimeOfConnectionread-onlymandatoryThe device registered to NET VISION
1.3.6.1.4.1.4555.1.1.7.1.8.5.1.5ColumnstatusOfConnectionread-onlymandatoryThe device status connection
1.3.6.1.4.1.4555.1.1.7.1.8.5.1.6ColumnseverityOfConnectionread-onlymandatoryThe device severity
1.3.6.1.4.1.4555.1.1.7.1.9NodeupsAgent
1.3.6.1.4.1.4555.1.1.7.1.9.1ScalarupsAgentIpaddressread-writemandatoryThe ip address that NMS can identify the managed device
1.3.6.1.4.1.4555.1.1.7.1.9.2ScalarupsAgentGatewayread-writemandatoryThe default gateway that allow device managed through routers
1.3.6.1.4.1.4555.1.1.7.1.9.3ScalarupsAgentSubnetMaskread-writemandatoryInternet address subnet mask
1.3.6.1.4.1.4555.1.1.7.1.9.4ScalarupsAgentDateread-writemandatoryThe date in agent, format is (dd/mm/yyyy)
1.3.6.1.4.1.4555.1.1.7.1.9.5ScalarupsAgentTimeread-writemandatoryThe time in agent, format is (hh:mm:ss)
1.3.6.1.4.1.4555.1.1.7.1.9.6ScalarupsAgentNtpTimeServerread-writemandatory
1.3.6.1.4.1.4555.1.1.7.1.9.7ScalarupsAgentNtpTimeZoneread-writemandatory
1.3.6.1.4.1.4555.1.1.7.1.9.8ScalarupsAgentHistoryLogFrequencyread-writemandatoryThe frequency of the updation of the history log. The value is in seconds
1.3.6.1.4.1.4555.1.1.7.1.9.9ScalarupsAgentExtHistoryLogFrequencyread-writemandatoryThe ups parameters are sampled at the rate governed by the mconfigHistroyLogFrequency. These sampled values are further conslidated over period of time which i…
1.3.6.1.4.1.4555.1.1.7.1.9.10ScalarupsAgentPollRateread-writemandatoryThe frequency that proxy agent polls the connected UPS in JBUS protocol. (unit : second)
1.3.6.1.4.1.4555.1.1.7.1.9.11ScalarupsAgentBaudRateread-onlymandatoryThe serial port communication speed. 2400,9600,19200,57600 allowed
1.3.6.1.4.1.4555.1.1.7.1.9.12ScalarupsAgentDhcpStatueread-writemandatoryEnable or disable DHCP/BootP capability
1.3.6.1.4.1.4555.1.1.7.1.9.13ScalarupsAgentTelnetStatusread-writemandatoryEnable or disable telnet access
1.3.6.1.4.1.4555.1.1.7.1.9.14ScalarupsAgentTftpStatusread-writemandatoryEnable or disable network upgrade capability
1.3.6.1.4.1.4555.1.1.7.1.9.15ScalarupsAgentResetToDefaultread-writemandatoryReset all parameters of Net Vision to default value
1.3.6.1.4.1.4555.1.1.7.1.9.16ScalarupsAgentRestartread-writemandatoryRestart Net Vision
1.3.6.1.4.1.4555.1.1.7.1.9.17ScalarupsAgentClearAgentLogread-writemandatoryClear agent log data
1.3.6.1.4.1.4555.1.1.7.1.9.18ScalarupsAgentClearEventLogread-writemandatoryClear event log data
1.3.6.1.4.1.4555.1.1.7.1.9.19ScalarupsAgentClearExtHistoryLogread-writemandatoryClear extented history log data
1.3.6.1.4.1.4555.1.1.7.1.9.20ScalarupsAgentClearHistoryLogread-writemandatoryClear history log data
1.3.6.1.4.1.4555.1.1.7.1.9.21TableupsAgentTrapsReceiversTablenot-accessiblemandatoryA list of managers to send traps to. The number of entries is given by the value of upsAgentNumTrapReceivers
1.3.6.1.4.1.4555.1.1.7.1.9.21.1RowupsAgentTrapsReceiversEntrynot-accessiblemandatoryThe managers to send traps to.
1.3.6.1.4.1.4555.1.1.7.1.9.21.1.1ColumntrapsIndexread-onlymandatoryThe index to a trap receiver entry.
1.3.6.1.4.1.4555.1.1.7.1.9.21.1.2ColumntrapsReceiverAddrread-writemandatoryThe IP address of the manager to send a trap to.
1.3.6.1.4.1.4555.1.1.7.1.9.21.1.3ColumnreceiverCommunityStringread-writemandatoryThe community name to use in the trap when sent to the manager.
1.3.6.1.4.1.4555.1.1.7.1.9.21.1.4ColumnreceiverNmstyperead-writemandatoryThe trap group that NMS desired.
1.3.6.1.4.1.4555.1.1.7.1.9.22TableupsAgentFirewallControlTablenot-accessiblemandatoryA list of managers which can access Net Vision with private community string.
1.3.6.1.4.1.4555.1.1.7.1.9.22.1RowupsAgentFirewallControlEntrynot-accessiblemandatoryThe managers.
1.3.6.1.4.1.4555.1.1.7.1.9.22.1.1ColumnfirewallIndexread-onlymandatoryThe index to a firewall entry.
1.3.6.1.4.1.4555.1.1.7.1.9.22.1.2ColumnfirewallControlAddrread-writemandatoryThe IP address of the firewall
1.3.6.1.4.1.4555.1.1.7.1.9.22.1.3ColumnfirewallPrefixLengthread-writemandatoryThe firewall prefix length.
1.3.6.1.4.1.4555.1.1.7.1.9.22.1.4ColumnfirewallActionModeread-writemandatoryThe firewall action mode
1.3.6.1.4.1.4555.1.1.7.1.9.23ScalarupsAgentMibVersionread-onlymandatoryThe version of MIB spec.
1.3.6.1.4.1.4555.1.1.7.1.10NodeemdStatus
1.3.6.1.4.1.4555.1.1.7.1.10.1ScalaremdSatatusTemperatureread-onlymandatoryThe measurement of EMD temperature, in 0.1 degree
1.3.6.1.4.1.4555.1.1.7.1.10.2ScalaremdSatatusHumidityread-onlymandatoryThe measurement of EMD humidity, in 0.1 degree
1.3.6.1.4.1.4555.1.1.7.1.10.3ScalaremdStatusIn1Activeread-onlymandatoryThe input 1 has been detected as Active
1.3.6.1.4.1.4555.1.1.7.1.10.4ScalaremdStatusIn2Activeread-onlymandatoryThe input 2 has been detected as Active
1.3.6.1.4.1.4555.1.1.7.2NodeupsTraps
1.3.6.1.4.1.4555.1.1.7.2.1NodeupsTrapOnBatteryWARNING:The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer run…
1.3.6.1.4.1.4555.1.1.7.2.2NodeupsTrapTestCompletedINFORMATION:This trap is sent upon completion of a UPS diagnostic test.
1.3.6.1.4.1.4555.1.1.7.2.3NodeupsTrapAlarmEntryAddedWARNING:This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for upsAlarmOnBattery and up…
1.3.6.1.4.1.4555.1.1.7.2.4NodeupsTrapAlarmEntryRemovedINFORMATION:This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for upsAlarmTestInProgress.
1.3.6.1.4.1.4555.1.1.7.2.5NodeupsTrapImminentStopCRITICAL: The UPS is near to switch off the output power.
1.3.6.1.4.1.4555.1.1.7.2.6NodeupsTrapOverloadWARNING: The UPS output is in overload. Output load rate more than 100%
1.3.6.1.4.1.4555.1.1.7.2.7NodeupsTrapRedundancyLostWARNING: Redundancy is lost.
1.3.6.1.4.1.4555.1.1.7.2.8NodeupsTrapBatteryCircuitOpenCRITICAL: The battery has been disconnected from UPS
1.3.6.1.4.1.4555.1.1.7.2.9NodeupsTrapBatteryDischargedCRITICAL: The battery has been detected as discharged.
1.3.6.1.4.1.4555.1.1.7.2.10NodeupsTrapBatteryLowCRITICAL: The battery is near of the end of backup time.
1.3.6.1.4.1.4555.1.1.7.2.11NodeupsTrapBatteryAlarmWARNING: The battery is in alarm.
1.3.6.1.4.1.4555.1.1.7.2.12NodeupsTrapUpsCriticalAlarmCRITICAL: A critical alarm has been detected on the UPS.
1.3.6.1.4.1.4555.1.1.7.2.13NodeupsTrapLoadOFFCRITICAL: The load has been disconnected from the UPS. LOAD OFF.
1.3.6.1.4.1.4555.1.1.7.2.14NodeupsTrapCommunicationLostCRITICAL: UPS is no more communicating with the agent.
1.3.6.1.4.1.4555.1.1.7.2.15NodeupsTrapOnBatteryPowerWARNING: The UPS has switched to battery backup power.
1.3.6.1.4.1.4555.1.1.7.2.16NodeupsTrapBatteryTestfailedWARNING: The Battery test has detected a weak battery.
1.3.6.1.4.1.4555.1.1.7.2.17NodeupsTrapTemperatureAlarmWARNING: The UPS internal temperature has reached the threshold.
1.3.6.1.4.1.4555.1.1.7.2.18NodeupsTrapOnBypassWARNING: Load supplied by automatic Bypass.
1.3.6.1.4.1.4555.1.1.7.2.19NodeupsTrapUpsPreventiveAlarmWARNING: A preventive alarm has been detected by the UPS.
1.3.6.1.4.1.4555.1.1.7.2.20NodeupsTrapShutdownWarningWARNING: A warning message has be sent to shutdown agent.
1.3.6.1.4.1.4555.1.1.7.2.21NodeupsTrapShutdownrequestWARNING: A shutdown command has been sent to agent.
1.3.6.1.4.1.4555.1.1.7.2.22NodeupsTrapUpsNormalINFORMATION: The UPS status is normal. Load protected by UPS
1.3.6.1.4.1.4555.1.1.7.2.23NodeupsTrapPowerRestoredINFORMATION: The Input supply has been restored
1.3.6.1.4.1.4555.1.1.7.2.24NodeupsTrapAlarmCancelledINFORMATION: Alarm cancelled. All alarms are disabled
1.3.6.1.4.1.4555.1.1.7.2.25NodeupsTrapComEstablishedINFORMATION: The communication between UPS and the agent has been restored
1.3.6.1.4.1.4555.1.1.7.2.26NodeupsTrapShutdwonCancelledINFORMATION: The UPS has cancelled the shutdown procedure to agent
1.3.6.1.4.1.4555.1.1.7.2.27NodeupsTrapAgentRestartingINFORMATION: NET VISION is restarting
1.3.6.1.4.1.4555.1.1.7.2.28NodeupsTrapEmdTempLowCRITICAL: EMD Sensor detected low temperature.
1.3.6.1.4.1.4555.1.1.7.2.29NodeupsTrapEmdTempNotLowINFORMATION: EMD Sensor Not under low temperature.
1.3.6.1.4.1.4555.1.1.7.2.30NodeupsTrapEmdTempHighCRITICAL: EMD Sensor detected high temperature.
1.3.6.1.4.1.4555.1.1.7.2.31NodeupsTrapEmdTempNotHighINFORMATION: EMD Sensor Not over high temperature.
1.3.6.1.4.1.4555.1.1.7.2.32NodeupsTrapEmdHumidityLowCRITICAL: EMD Sensor detected low humidity.
1.3.6.1.4.1.4555.1.1.7.2.33NodeupsTrapEmdHumidityNotLowINFORMATION: EMD Sensor Not under low humidity.
1.3.6.1.4.1.4555.1.1.7.2.34NodeupsTrapEmdHumidityHighCRITICAL: EMD Sensor detected high humidity.
1.3.6.1.4.1.4555.1.1.7.2.35NodeupsTrapEmdHumidityNotHighINFORMATION: EMD Sensor Not over high humidity.
1.3.6.1.4.1.4555.1.1.7.2.36NodeupsTrapEmdFirstInputActiveCRITICAL: The <customized string_1> input is active.
1.3.6.1.4.1.4555.1.1.7.2.37NodeupsTrapEmdFirstInputRestoredINFORMATION: The <customized string_1> input is restored.
1.3.6.1.4.1.4555.1.1.7.2.38NodeupsTrapEmdSecondInputActiveCRITICAL: The <customized string_2> input is active.
1.3.6.1.4.1.4555.1.1.7.2.39NodeupsTrapEmdSecondInputRestoredINFORMATION: The <customized string_2> input is restored.
1.3.6.1.4.1.4555.1.1.7.2.40NodeupsTrapSessionLoginINFORMATION: New Admin or User session opened.
1.3.6.1.4.1.4555.1.1.7.2.41NodeupsTrapLoginUnsuccesfulTentativeWARNING: Admin or User account locked.
1.3.6.1.4.1.4555.1.1.7.2.42NodeupsTrapTestINFORMATION: Send test trap.