SPS2v1-MIB
1641 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | enterprises |
| RFC1213-MIB | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.42610 | Nodepowertek | |||
| 1.3.6.1.4.1.42610.1 | Nodeproduct | |||
| 1.3.6.1.4.1.42610.1.4 | Nodepdu | |||
| 1.3.6.1.4.1.42610.1.4.1 | Nodepwt2 | |||
| 1.3.6.1.4.1.42610.1.4.1.1 | NodepduObjects | |||
| 1.3.6.1.4.1.42610.1.4.1.1.1 | NodepduIdent | |||
| 1.3.6.1.4.1.42610.1.4.1.1.1.1 | ScalarpduIdentAgentSoftwareVersion | read-only | mandatory | The firmware version of the device. |
| 1.3.6.1.4.1.42610.1.4.1.1.1.2 | ScalarpduIdentSerialNumber | read-only | mandatory | A Model of this device. |
| 1.3.6.1.4.1.42610.1.4.1.1.2 | NodepduDevMon | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.1 | NodepduDevMonInlet | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1 | TablepduDevMonInletTable | not-accessible | mandatory | A list to display information of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1 | RowpduDevMonInletEntry | not-accessible | mandatory | A list to display information of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.1 | ColumnpduDevMonInletIndex | read-only | mandatory | The index to a inlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.2 | ColumnpduDevMonInletName | read-only | mandatory | The name of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.3 | ColumnpduDevMonInletBid | read-only | mandatory | The board id of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.4 | ColumnpduDevMonInletFwType | read-only | mandatory | The firmware type of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.5 | ColumnpduDevMonInletVoltPh1 | read-only | mandatory | The phase1 voltage of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.6 | ColumnpduDevMonInletVoltPh2 | read-only | mandatory | The phase2 voltage of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.7 | ColumnpduDevMonInletVoltPh3 | read-only | mandatory | The phase3 voltage of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.8 | ColumnpduDevMonInletPfPh1B1 | read-only | mandatory | The phase1b1 pf of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.9 | ColumnpduDevMonInletPfPh2B1 | read-only | mandatory | The phase2b1 pf of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.10 | ColumnpduDevMonInletPfPh3B1 | read-only | mandatory | The phase3b1 pf of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.11 | ColumnpduDevMonInletPfPh1B2 | read-only | mandatory | The phase1b2 pf of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.12 | ColumnpduDevMonInletPfPh2B2 | read-only | mandatory | The phase2b2 pf of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.13 | ColumnpduDevMonInletPfPh3B2 | read-only | mandatory | The phase3b2 pf of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.14 | ColumnpduDevMonInletCurrentPh1B1 | read-only | mandatory | The phase1b1 current of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.15 | ColumnpduDevMonInletCurrentPh2B1 | read-only | mandatory | The phase2b1 current of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.16 | ColumnpduDevMonInletCurrentPh3B1 | read-only | mandatory | The phase3b1 current of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.17 | ColumnpduDevMonInletCurrentPh1B2 | read-only | mandatory | The phase1b2 current of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.18 | ColumnpduDevMonInletCurrentPh2B2 | read-only | mandatory | The phase2b2 current of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.19 | ColumnpduDevMonInletCurrentPh3B2 | read-only | mandatory | The phase3b2 voltage of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.20 | ColumnpduDevMonInletActPowerPh1 | read-only | mandatory | The phase1 act power of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.21 | ColumnpduDevMonInletActPowerPh2 | read-only | mandatory | The phase2 act power of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.22 | ColumnpduDevMonInletActPowerPh3 | read-only | mandatory | The phase3 act power of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.23 | ColumnpduDevMonInletAppPowerPh1 | read-only | mandatory | The phase1 app power of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.24 | ColumnpduDevMonInletAppPowerPh2 | read-only | mandatory | The phase2 app power of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.25 | ColumnpduDevMonInletAppPowerPh3 | read-only | mandatory | The phase3 app power of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.26 | ColumnpduDevMonInletEnergyPh1 | read-only | mandatory | The phase1 energy of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.27 | ColumnpduDevMonInletEnergyPh2 | read-only | mandatory | The phase2 energy of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.28 | ColumnpduDevMonInletEnergyPh3 | read-only | mandatory | The phase3 energy of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.29 | ColumnpduDevMonInletEnergyTimePh1 | read-only | mandatory | The phase1 energy time of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.30 | ColumnpduDevMonInletEnergyTimePh2 | read-only | mandatory | The phase2 energy time of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.31 | ColumnpduDevMonInletEnergyTimePh3 | read-only | mandatory | The phase3 energy time of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.32 | ColumnpduDevMonInletLoadBalance | read-only | mandatory | The load balance of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.33 | ColumnpduDevMonInletEvtOverLoad | read-only | mandatory | The over load of status inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.34 | ColumnpduDevMonInletEvtStatusPh1 | read-only | mandatory | The phase1 status of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.35 | ColumnpduDevMonInletEvtStatusPh2 | read-only | mandatory | The phase2 status of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.36 | ColumnpduDevMonInletEvtStatusPh3 | read-only | mandatory | The phase3 status of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.37 | ColumnpduDevMonInletEvtLoadBalance | read-only | mandatory | The load balance of status inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.38 | ColumnpduDevMonInletRcmValid | read-only | mandatory | The current leak is valid. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.39 | ColumnpduDevMonInletRcmCurrent | read-only | mandatory | Current value of leakage current. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.40 | ColumnpduDevMonInletRcmAlarm | read-only | mandatory | Current leak alarm status. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.1.1.1.41 | ColumnpduDevMonInletPowerShare | read-only | mandatory | Power share status. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2 | NodepduDevMonOutlet | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.1 | NodepduDevMonOutletMaster | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.1.1 | ScalarpduDevMonOutletMasterPortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.1.2 | TablepduDevMonOutletMasterPortTable | not-accessible | mandatory | Display the port information list of MasterPort. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.1.2.1 | RowpduDevMonOutletMasterPortEntry | not-accessible | mandatory | Display the port information list of MasterPort.. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.1.2.1.1 | ColumnpduDevMonOutletMasterPortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.1.2.1.2 | ColumnpduDevMonOutletMasterPortName | read-only | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.1.2.1.3 | ColumnpduDevMonOutletMasterPortBid | read-only | mandatory | The board id of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.1.2.1.4 | ColumnpduDevMonOutletMasterPortFwType | read-only | mandatory | The firmware type of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.1.2.1.5 | ColumnpduDevMonOutletMasterPortRlyState | read-only | mandatory | The relay state of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.1.2.1.6 | ColumnpduDevMonOutletMasterPortEvtStatus | read-only | mandatory | The event status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.1.2.1.7 | ColumnpduDevMonOutletMasterPortVolt | read-only | mandatory | The voltage of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.1.2.1.8 | ColumnpduDevMonOutletMasterPortCurrent | read-only | mandatory | The current of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.1.2.1.9 | ColumnpduDevMonOutletMasterPortPf | read-only | mandatory | The pf of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.1.2.1.10 | ColumnpduDevMonOutletMasterPortActPower | read-only | mandatory | The act power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.1.2.1.11 | ColumnpduDevMonOutletMasterPortAppPower | read-only | mandatory | The app power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.1.2.1.12 | ColumnpduDevMonOutletMasterPortEnergy | read-only | mandatory | The energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.1.2.1.13 | ColumnpduDevMonOutletMasterPortEnergyTime | read-only | mandatory | The energy time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.2 | NodepduDevMonOutletSlave01 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.2.1 | ScalarpduDevMonOutletSlave01PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.2.2 | TablepduDevMonOutletSlave01PortTable | not-accessible | mandatory | Display the port information list of Slave01Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.2.2.1 | RowpduDevMonOutletSlave01PortEntry | not-accessible | mandatory | Display the port information list of Slave01Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.2.2.1.1 | ColumnpduDevMonOutletSlave01PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.2.2.1.2 | ColumnpduDevMonOutletSlave01PortName | read-only | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.2.2.1.3 | ColumnpduDevMonOutletSlave01PortBid | read-only | mandatory | The board id of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.2.2.1.4 | ColumnpduDevMonOutletSlave01PortFwType | read-only | mandatory | The firmware type of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.2.2.1.5 | ColumnpduDevMonOutletSlave01PortRlyState | read-only | mandatory | The relay state of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.2.2.1.6 | ColumnpduDevMonOutletSlave01PortEvtStatus | read-only | mandatory | The event status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.2.2.1.7 | ColumnpduDevMonOutletSlave01PortVolt | read-only | mandatory | The voltage of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.2.2.1.8 | ColumnpduDevMonOutletSlave01PortCurrent | read-only | mandatory | The current of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.2.2.1.9 | ColumnpduDevMonOutletSlave01PortPf | read-only | mandatory | The pf of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.2.2.1.10 | ColumnpduDevMonOutletSlave01PortActPower | read-only | mandatory | The act power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.2.2.1.11 | ColumnpduDevMonOutletSlave01PortAppPower | read-only | mandatory | The app power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.2.2.1.12 | ColumnpduDevMonOutletSlave01PortEnergy | read-only | mandatory | The energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.2.2.1.13 | ColumnpduDevMonOutletSlave01PortEnergyTime | read-only | mandatory | The energy time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.3 | NodepduDevMonOutletSlave02 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.3.1 | ScalarpduDevMonOutletSlave02PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.3.2 | TablepduDevMonOutletSlave02PortTable | not-accessible | mandatory | Display the port information list of Slave02Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.3.2.1 | RowpduDevMonOutletSlave02PortEntry | not-accessible | mandatory | Display the port information list of Slave02Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.3.2.1.1 | ColumnpduDevMonOutletSlave02PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.3.2.1.2 | ColumnpduDevMonOutletSlave02PortName | read-only | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.3.2.1.3 | ColumnpduDevMonOutletSlave02PortBid | read-only | mandatory | The board id of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.3.2.1.4 | ColumnpduDevMonOutletSlave02PortFwType | read-only | mandatory | The firmware type of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.3.2.1.5 | ColumnpduDevMonOutletSlave02PortRlyState | read-only | mandatory | The relay state of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.3.2.1.6 | ColumnpduDevMonOutletSlave02PortEvtStatus | read-only | mandatory | The event status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.3.2.1.7 | ColumnpduDevMonOutletSlave02PortVolt | read-only | mandatory | The voltage of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.3.2.1.8 | ColumnpduDevMonOutletSlave02PortCurrent | read-only | mandatory | The current of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.3.2.1.9 | ColumnpduDevMonOutletSlave02PortPf | read-only | mandatory | The pf of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.3.2.1.10 | ColumnpduDevMonOutletSlave02PortActPower | read-only | mandatory | The act power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.3.2.1.11 | ColumnpduDevMonOutletSlave02PortAppPower | read-only | mandatory | The app power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.3.2.1.12 | ColumnpduDevMonOutletSlave02PortEnergy | read-only | mandatory | The energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.3.2.1.13 | ColumnpduDevMonOutletSlave02PortEnergyTime | read-only | mandatory | The energy time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.4 | NodepduDevMonOutletSlave03 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.4.1 | ScalarpduDevMonOutletSlave03PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.4.2 | TablepduDevMonOutletSlave03PortTable | not-accessible | mandatory | Display the port information list of Slave03Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.4.2.1 | RowpduDevMonOutletSlave03PortEntry | not-accessible | mandatory | Display the port information list of Slave03Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.4.2.1.1 | ColumnpduDevMonOutletSlave03PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.4.2.1.2 | ColumnpduDevMonOutletSlave03PortName | read-only | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.4.2.1.3 | ColumnpduDevMonOutletSlave03PortBid | read-only | mandatory | The board id of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.4.2.1.4 | ColumnpduDevMonOutletSlave03PortFwType | read-only | mandatory | The firmware type of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.4.2.1.5 | ColumnpduDevMonOutletSlave03PortRlyState | read-only | mandatory | The relay state of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.4.2.1.6 | ColumnpduDevMonOutletSlave03PortEvtStatus | read-only | mandatory | The event status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.4.2.1.7 | ColumnpduDevMonOutletSlave03PortVolt | read-only | mandatory | The voltage of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.4.2.1.8 | ColumnpduDevMonOutletSlave03PortCurrent | read-only | mandatory | The current of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.4.2.1.9 | ColumnpduDevMonOutletSlave03PortPf | read-only | mandatory | The pf of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.4.2.1.10 | ColumnpduDevMonOutletSlave03PortActPower | read-only | mandatory | The act power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.4.2.1.11 | ColumnpduDevMonOutletSlave03PortAppPower | read-only | mandatory | The app power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.4.2.1.12 | ColumnpduDevMonOutletSlave03PortEnergy | read-only | mandatory | The energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.4.2.1.13 | ColumnpduDevMonOutletSlave03PortEnergyTime | read-only | mandatory | The energy time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.5 | NodepduDevMonOutletSlave04 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.5.1 | ScalarpduDevMonOutletSlave04PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.5.2 | TablepduDevMonOutletSlave04PortTable | not-accessible | mandatory | Display the port information list of Slave04Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.5.2.1 | RowpduDevMonOutletSlave04PortEntry | not-accessible | mandatory | Display the port information list of Slave04Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.5.2.1.1 | ColumnpduDevMonOutletSlave04PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.5.2.1.2 | ColumnpduDevMonOutletSlave04PortName | read-only | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.5.2.1.3 | ColumnpduDevMonOutletSlave04PortBid | read-only | mandatory | The board id of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.5.2.1.4 | ColumnpduDevMonOutletSlave04PortFwType | read-only | mandatory | The firmware type of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.5.2.1.5 | ColumnpduDevMonOutletSlave04PortRlyState | read-only | mandatory | The relay state of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.5.2.1.6 | ColumnpduDevMonOutletSlave04PortEvtStatus | read-only | mandatory | The event status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.5.2.1.7 | ColumnpduDevMonOutletSlave04PortVolt | read-only | mandatory | The voltage of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.5.2.1.8 | ColumnpduDevMonOutletSlave04PortCurrent | read-only | mandatory | The current of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.5.2.1.9 | ColumnpduDevMonOutletSlave04PortPf | read-only | mandatory | The pf of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.5.2.1.10 | ColumnpduDevMonOutletSlave04PortActPower | read-only | mandatory | The act power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.5.2.1.11 | ColumnpduDevMonOutletSlave04PortAppPower | read-only | mandatory | The app power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.5.2.1.12 | ColumnpduDevMonOutletSlave04PortEnergy | read-only | mandatory | The energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.5.2.1.13 | ColumnpduDevMonOutletSlave04PortEnergyTime | read-only | mandatory | The energy time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.6 | NodepduDevMonOutletSlave05 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.6.1 | ScalarpduDevMonOutletSlave05PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.6.2 | TablepduDevMonOutletSlave05PortTable | not-accessible | mandatory | Display the port information list of Slave05Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.6.2.1 | RowpduDevMonOutletSlave05PortEntry | not-accessible | mandatory | Display the port information list of Slave05Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.6.2.1.1 | ColumnpduDevMonOutletSlave05PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.6.2.1.2 | ColumnpduDevMonOutletSlave05PortName | read-only | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.6.2.1.3 | ColumnpduDevMonOutletSlave05PortBid | read-only | mandatory | The board id of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.6.2.1.4 | ColumnpduDevMonOutletSlave05PortFwType | read-only | mandatory | The firmware type of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.6.2.1.5 | ColumnpduDevMonOutletSlave05PortRlyState | read-only | mandatory | The relay state of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.6.2.1.6 | ColumnpduDevMonOutletSlave05PortEvtStatus | read-only | mandatory | The event status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.6.2.1.7 | ColumnpduDevMonOutletSlave05PortVolt | read-only | mandatory | The voltage of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.6.2.1.8 | ColumnpduDevMonOutletSlave05PortCurrent | read-only | mandatory | The current of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.6.2.1.9 | ColumnpduDevMonOutletSlave05PortPf | read-only | mandatory | The pf of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.6.2.1.10 | ColumnpduDevMonOutletSlave05PortActPower | read-only | mandatory | The act power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.6.2.1.11 | ColumnpduDevMonOutletSlave05PortAppPower | read-only | mandatory | The app power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.6.2.1.12 | ColumnpduDevMonOutletSlave05PortEnergy | read-only | mandatory | The energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.6.2.1.13 | ColumnpduDevMonOutletSlave05PortEnergyTime | read-only | mandatory | The energy time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.7 | NodepduDevMonOutletSlave06 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.7.1 | ScalarpduDevMonOutletSlave06PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.7.2 | TablepduDevMonOutletSlave06PortTable | not-accessible | mandatory | Display the port information list of Slave06Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.7.2.1 | RowpduDevMonOutletSlave06PortEntry | not-accessible | mandatory | Display the port information list of Slave06Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.7.2.1.1 | ColumnpduDevMonOutletSlave06PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.7.2.1.2 | ColumnpduDevMonOutletSlave06PortName | read-only | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.7.2.1.3 | ColumnpduDevMonOutletSlave06PortBid | read-only | mandatory | The board id of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.7.2.1.4 | ColumnpduDevMonOutletSlave06PortFwType | read-only | mandatory | The firmware type of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.7.2.1.5 | ColumnpduDevMonOutletSlave06PortRlyState | read-only | mandatory | The relay state of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.7.2.1.6 | ColumnpduDevMonOutletSlave06PortEvtStatus | read-only | mandatory | The event status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.7.2.1.7 | ColumnpduDevMonOutletSlave06PortVolt | read-only | mandatory | The voltage of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.7.2.1.8 | ColumnpduDevMonOutletSlave06PortCurrent | read-only | mandatory | The current of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.7.2.1.9 | ColumnpduDevMonOutletSlave06PortPf | read-only | mandatory | The pf of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.7.2.1.10 | ColumnpduDevMonOutletSlave06PortActPower | read-only | mandatory | The act power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.7.2.1.11 | ColumnpduDevMonOutletSlave06PortAppPower | read-only | mandatory | The app power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.7.2.1.12 | ColumnpduDevMonOutletSlave06PortEnergy | read-only | mandatory | The energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.7.2.1.13 | ColumnpduDevMonOutletSlave06PortEnergyTime | read-only | mandatory | The energy time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.8 | NodepduDevMonOutletSlave07 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.8.1 | ScalarpduDevMonOutletSlave07PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.8.2 | TablepduDevMonOutletSlave07PortTable | not-accessible | mandatory | Display the port information list of Slave07Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.8.2.1 | RowpduDevMonOutletSlave07PortEntry | not-accessible | mandatory | Display the port information list of Slave07Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.8.2.1.1 | ColumnpduDevMonOutletSlave07PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.8.2.1.2 | ColumnpduDevMonOutletSlave07PortName | read-only | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.8.2.1.3 | ColumnpduDevMonOutletSlave07PortBid | read-only | mandatory | The board id of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.8.2.1.4 | ColumnpduDevMonOutletSlave07PortFwType | read-only | mandatory | The firmware type of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.8.2.1.5 | ColumnpduDevMonOutletSlave07PortRlyState | read-only | mandatory | The relay state of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.8.2.1.6 | ColumnpduDevMonOutletSlave07PortEvtStatus | read-only | mandatory | The event status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.8.2.1.7 | ColumnpduDevMonOutletSlave07PortVolt | read-only | mandatory | The voltage of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.8.2.1.8 | ColumnpduDevMonOutletSlave07PortCurrent | read-only | mandatory | The current of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.8.2.1.9 | ColumnpduDevMonOutletSlave07PortPf | read-only | mandatory | The pf of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.8.2.1.10 | ColumnpduDevMonOutletSlave07PortActPower | read-only | mandatory | The act power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.8.2.1.11 | ColumnpduDevMonOutletSlave07PortAppPower | read-only | mandatory | The app power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.8.2.1.12 | ColumnpduDevMonOutletSlave07PortEnergy | read-only | mandatory | The energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.8.2.1.13 | ColumnpduDevMonOutletSlave07PortEnergyTime | read-only | mandatory | The energy time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.9 | NodepduDevMonOutletSlave08 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.9.1 | ScalarpduDevMonOutletSlave08PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.9.2 | TablepduDevMonOutletSlave08PortTable | not-accessible | mandatory | Display the port information list of Slave08Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.9.2.1 | RowpduDevMonOutletSlave08PortEntry | not-accessible | mandatory | Display the port information list of Slave08Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.9.2.1.1 | ColumnpduDevMonOutletSlave08PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.9.2.1.2 | ColumnpduDevMonOutletSlave08PortName | read-only | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.9.2.1.3 | ColumnpduDevMonOutletSlave08PortBid | read-only | mandatory | The board id of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.9.2.1.4 | ColumnpduDevMonOutletSlave08PortFwType | read-only | mandatory | The firmware type of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.9.2.1.5 | ColumnpduDevMonOutletSlave08PortRlyState | read-only | mandatory | The relay state of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.9.2.1.6 | ColumnpduDevMonOutletSlave08PortEvtStatus | read-only | mandatory | The event status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.9.2.1.7 | ColumnpduDevMonOutletSlave08PortVolt | read-only | mandatory | The voltage of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.9.2.1.8 | ColumnpduDevMonOutletSlave08PortCurrent | read-only | mandatory | The current of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.9.2.1.9 | ColumnpduDevMonOutletSlave08PortPf | read-only | mandatory | The pf of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.9.2.1.10 | ColumnpduDevMonOutletSlave08PortActPower | read-only | mandatory | The act power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.9.2.1.11 | ColumnpduDevMonOutletSlave08PortAppPower | read-only | mandatory | The app power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.9.2.1.12 | ColumnpduDevMonOutletSlave08PortEnergy | read-only | mandatory | The energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.9.2.1.13 | ColumnpduDevMonOutletSlave08PortEnergyTime | read-only | mandatory | The energy time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.10 | NodepduDevMonOutletSlave09 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.10.1 | ScalarpduDevMonOutletSlave09PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.10.2 | TablepduDevMonOutletSlave09PortTable | not-accessible | mandatory | Display the port information list of Slave09Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.10.2.1 | RowpduDevMonOutletSlave09PortEntry | not-accessible | mandatory | Display the port information list of Slave09Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.10.2.1.1 | ColumnpduDevMonOutletSlave09PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.10.2.1.2 | ColumnpduDevMonOutletSlave09PortName | read-only | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.10.2.1.3 | ColumnpduDevMonOutletSlave09PortBid | read-only | mandatory | The board id of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.10.2.1.4 | ColumnpduDevMonOutletSlave09PortFwType | read-only | mandatory | The firmware type of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.10.2.1.5 | ColumnpduDevMonOutletSlave09PortRlyState | read-only | mandatory | The relay state of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.10.2.1.6 | ColumnpduDevMonOutletSlave09PortEvtStatus | read-only | mandatory | The event status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.10.2.1.7 | ColumnpduDevMonOutletSlave09PortVolt | read-only | mandatory | The voltage of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.10.2.1.8 | ColumnpduDevMonOutletSlave09PortCurrent | read-only | mandatory | The current of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.10.2.1.9 | ColumnpduDevMonOutletSlave09PortPf | read-only | mandatory | The pf of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.10.2.1.10 | ColumnpduDevMonOutletSlave09PortActPower | read-only | mandatory | The act power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.10.2.1.11 | ColumnpduDevMonOutletSlave09PortAppPower | read-only | mandatory | The app power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.10.2.1.12 | ColumnpduDevMonOutletSlave09PortEnergy | read-only | mandatory | The energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.10.2.1.13 | ColumnpduDevMonOutletSlave09PortEnergyTime | read-only | mandatory | The energy time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.11 | NodepduDevMonOutletSlave10 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.11.1 | ScalarpduDevMonOutletSlave10PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.11.2 | TablepduDevMonOutletSlave10PortTable | not-accessible | mandatory | Display the port information list of Slave10Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.11.2.1 | RowpduDevMonOutletSlave10PortEntry | not-accessible | mandatory | Display the port information list of Slave10Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.11.2.1.1 | ColumnpduDevMonOutletSlave10PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.11.2.1.2 | ColumnpduDevMonOutletSlave10PortName | read-only | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.11.2.1.3 | ColumnpduDevMonOutletSlave10PortBid | read-only | mandatory | The board id of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.11.2.1.4 | ColumnpduDevMonOutletSlave10PortFwType | read-only | mandatory | The firmware type of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.11.2.1.5 | ColumnpduDevMonOutletSlave10PortRlyState | read-only | mandatory | The relay state of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.11.2.1.6 | ColumnpduDevMonOutletSlave10PortEvtStatus | read-only | mandatory | The event status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.11.2.1.7 | ColumnpduDevMonOutletSlave10PortVolt | read-only | mandatory | The voltage of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.11.2.1.8 | ColumnpduDevMonOutletSlave10PortCurrent | read-only | mandatory | The current of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.11.2.1.9 | ColumnpduDevMonOutletSlave10PortPf | read-only | mandatory | The pf of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.11.2.1.10 | ColumnpduDevMonOutletSlave10PortActPower | read-only | mandatory | The act power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.11.2.1.11 | ColumnpduDevMonOutletSlave10PortAppPower | read-only | mandatory | The app power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.11.2.1.12 | ColumnpduDevMonOutletSlave10PortEnergy | read-only | mandatory | The energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.11.2.1.13 | ColumnpduDevMonOutletSlave10PortEnergyTime | read-only | mandatory | The energy time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.12 | NodepduDevMonOutletSlave11 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.12.1 | ScalarpduDevMonOutletSlave11PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.12.2 | TablepduDevMonOutletSlave11PortTable | not-accessible | mandatory | Display the port information list of Slave11Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.12.2.1 | RowpduDevMonOutletSlave11PortEntry | not-accessible | mandatory | Display the port information list of Slave11Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.12.2.1.1 | ColumnpduDevMonOutletSlave11PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.12.2.1.2 | ColumnpduDevMonOutletSlave11PortName | read-only | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.12.2.1.3 | ColumnpduDevMonOutletSlave11PortBid | read-only | mandatory | The board id of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.12.2.1.4 | ColumnpduDevMonOutletSlave11PortFwType | read-only | mandatory | The firmware type of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.12.2.1.5 | ColumnpduDevMonOutletSlave11PortRlyState | read-only | mandatory | The relay state of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.12.2.1.6 | ColumnpduDevMonOutletSlave11PortEvtStatus | read-only | mandatory | The event status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.12.2.1.7 | ColumnpduDevMonOutletSlave11PortVolt | read-only | mandatory | The voltage of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.12.2.1.8 | ColumnpduDevMonOutletSlave11PortCurrent | read-only | mandatory | The current of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.12.2.1.9 | ColumnpduDevMonOutletSlave11PortPf | read-only | mandatory | The pf of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.12.2.1.10 | ColumnpduDevMonOutletSlave11PortActPower | read-only | mandatory | The act power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.12.2.1.11 | ColumnpduDevMonOutletSlave11PortAppPower | read-only | mandatory | The app power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.12.2.1.12 | ColumnpduDevMonOutletSlave11PortEnergy | read-only | mandatory | The energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.12.2.1.13 | ColumnpduDevMonOutletSlave11PortEnergyTime | read-only | mandatory | The energy time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.13 | NodepduDevMonOutletSlave12 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.13.1 | ScalarpduDevMonOutletSlave12PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.13.2 | TablepduDevMonOutletSlave12PortTable | not-accessible | mandatory | Display the port information list of Slave12Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.13.2.1 | RowpduDevMonOutletSlave12PortEntry | not-accessible | mandatory | Display the port information list of Slave12Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.13.2.1.1 | ColumnpduDevMonOutletSlave12PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.13.2.1.2 | ColumnpduDevMonOutletSlave12PortName | read-only | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.13.2.1.3 | ColumnpduDevMonOutletSlave12PortBid | read-only | mandatory | The board id of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.13.2.1.4 | ColumnpduDevMonOutletSlave12PortFwType | read-only | mandatory | The firmware type of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.13.2.1.5 | ColumnpduDevMonOutletSlave12PortRlyState | read-only | mandatory | The relay state of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.13.2.1.6 | ColumnpduDevMonOutletSlave12PortEvtStatus | read-only | mandatory | The event status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.13.2.1.7 | ColumnpduDevMonOutletSlave12PortVolt | read-only | mandatory | The voltage of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.13.2.1.8 | ColumnpduDevMonOutletSlave12PortCurrent | read-only | mandatory | The current of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.13.2.1.9 | ColumnpduDevMonOutletSlave12PortPf | read-only | mandatory | The pf of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.13.2.1.10 | ColumnpduDevMonOutletSlave12PortActPower | read-only | mandatory | The act power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.13.2.1.11 | ColumnpduDevMonOutletSlave12PortAppPower | read-only | mandatory | The app power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.13.2.1.12 | ColumnpduDevMonOutletSlave12PortEnergy | read-only | mandatory | The energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.13.2.1.13 | ColumnpduDevMonOutletSlave12PortEnergyTime | read-only | mandatory | The energy time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.14 | NodepduDevMonOutletSlave13 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.14.1 | ScalarpduDevMonOutletSlave13PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.14.2 | TablepduDevMonOutletSlave13PortTable | not-accessible | mandatory | Display the port information list of Slave13Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.14.2.1 | RowpduDevMonOutletSlave13PortEntry | not-accessible | mandatory | Display the port information list of Slave13Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.14.2.1.1 | ColumnpduDevMonOutletSlave13PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.14.2.1.2 | ColumnpduDevMonOutletSlave13PortName | read-only | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.14.2.1.3 | ColumnpduDevMonOutletSlave13PortBid | read-only | mandatory | The board id of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.14.2.1.4 | ColumnpduDevMonOutletSlave13PortFwType | read-only | mandatory | The firmware type of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.14.2.1.5 | ColumnpduDevMonOutletSlave13PortRlyState | read-only | mandatory | The relay state of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.14.2.1.6 | ColumnpduDevMonOutletSlave13PortEvtStatus | read-only | mandatory | The event status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.14.2.1.7 | ColumnpduDevMonOutletSlave13PortVolt | read-only | mandatory | The voltage of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.14.2.1.8 | ColumnpduDevMonOutletSlave13PortCurrent | read-only | mandatory | The current of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.14.2.1.9 | ColumnpduDevMonOutletSlave13PortPf | read-only | mandatory | The pf of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.14.2.1.10 | ColumnpduDevMonOutletSlave13PortActPower | read-only | mandatory | The act power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.14.2.1.11 | ColumnpduDevMonOutletSlave13PortAppPower | read-only | mandatory | The app power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.14.2.1.12 | ColumnpduDevMonOutletSlave13PortEnergy | read-only | mandatory | The energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.14.2.1.13 | ColumnpduDevMonOutletSlave13PortEnergyTime | read-only | mandatory | The energy time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.15 | NodepduDevMonOutletSlave14 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.15.1 | ScalarpduDevMonOutletSlave14PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.15.2 | TablepduDevMonOutletSlave14PortTable | not-accessible | mandatory | Display the port information list of Slave14Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.15.2.1 | RowpduDevMonOutletSlave14PortEntry | not-accessible | mandatory | Display the port information list of Slave14Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.15.2.1.1 | ColumnpduDevMonOutletSlave14PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.15.2.1.2 | ColumnpduDevMonOutletSlave14PortName | read-only | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.15.2.1.3 | ColumnpduDevMonOutletSlave14PortBid | read-only | mandatory | The board id of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.15.2.1.4 | ColumnpduDevMonOutletSlave14PortFwType | read-only | mandatory | The firmware type of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.15.2.1.5 | ColumnpduDevMonOutletSlave14PortRlyState | read-only | mandatory | The relay state of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.15.2.1.6 | ColumnpduDevMonOutletSlave14PortEvtStatus | read-only | mandatory | The event status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.15.2.1.7 | ColumnpduDevMonOutletSlave14PortVolt | read-only | mandatory | The voltage of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.15.2.1.8 | ColumnpduDevMonOutletSlave14PortCurrent | read-only | mandatory | The current of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.15.2.1.9 | ColumnpduDevMonOutletSlave14PortPf | read-only | mandatory | The pf of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.15.2.1.10 | ColumnpduDevMonOutletSlave14PortActPower | read-only | mandatory | The act power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.15.2.1.11 | ColumnpduDevMonOutletSlave14PortAppPower | read-only | mandatory | The app power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.15.2.1.12 | ColumnpduDevMonOutletSlave14PortEnergy | read-only | mandatory | The energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.15.2.1.13 | ColumnpduDevMonOutletSlave14PortEnergyTime | read-only | mandatory | The energy time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.16 | NodepduDevMonOutletSlave15 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.16.1 | ScalarpduDevMonOutletSlave15PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.16.2 | TablepduDevMonOutletSlave15PortTable | not-accessible | mandatory | Display the port information list of Slave15Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.16.2.1 | RowpduDevMonOutletSlave15PortEntry | not-accessible | mandatory | Display the port information list of Slave15Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.16.2.1.1 | ColumnpduDevMonOutletSlave15PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.16.2.1.2 | ColumnpduDevMonOutletSlave15PortName | read-only | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.16.2.1.3 | ColumnpduDevMonOutletSlave15PortBid | read-only | mandatory | The board id of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.16.2.1.4 | ColumnpduDevMonOutletSlave15PortFwType | read-only | mandatory | The firmware type of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.16.2.1.5 | ColumnpduDevMonOutletSlave15PortRlyState | read-only | mandatory | The relay state of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.16.2.1.6 | ColumnpduDevMonOutletSlave15PortEvtStatus | read-only | mandatory | The event status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.16.2.1.7 | ColumnpduDevMonOutletSlave15PortVolt | read-only | mandatory | The voltage of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.16.2.1.8 | ColumnpduDevMonOutletSlave15PortCurrent | read-only | mandatory | The current of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.16.2.1.9 | ColumnpduDevMonOutletSlave15PortPf | read-only | mandatory | The pf of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.16.2.1.10 | ColumnpduDevMonOutletSlave15PortActPower | read-only | mandatory | The act power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.16.2.1.11 | ColumnpduDevMonOutletSlave15PortAppPower | read-only | mandatory | The app power of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.16.2.1.12 | ColumnpduDevMonOutletSlave15PortEnergy | read-only | mandatory | The energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.2.16.2.1.13 | ColumnpduDevMonOutletSlave15PortEnergyTime | read-only | mandatory | The energy time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3 | NodepduDevMonEmd | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.1 | NodepduDevMonEmdMaster | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.1.1 | TablepduDevMonEmdMasterTable | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.1.1.1 | RowpduDevMonEmdMasterEntry | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.1.1.1.1 | ColumnpduDevMonEmdMasterIndex | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.1.1.1.2 | ColumnpduDevMonEmdMasterValid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.1.1.1.3 | ColumnpduDevMonEmdMasterType | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.1.1.1.4 | ColumnpduDevMonEmdMasterName | read-only | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.1.1.1.5 | ColumnpduDevMonEmdMasterTempName | read-only | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.1.1.1.6 | ColumnpduDevMonEmdMasterHumiName | read-only | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.1.1.1.7 | ColumnpduDevMonEmdMasterAlarm1Name | read-only | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.1.1.1.8 | ColumnpduDevMonEmdMasterAlarm2Name | read-only | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.1.1.1.9 | ColumnpduDevMonEmdMasterTemp | read-only | mandatory | The temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.1.1.1.10 | ColumnpduDevMonEmdMasterHumi | read-only | mandatory | The humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.1.1.1.11 | ColumnpduDevMonEmdMasterTempSt | read-only | mandatory | The temp status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.1.1.1.12 | ColumnpduDevMonEmdMasterHumiSt | read-only | mandatory | The humi status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.1.1.1.13 | ColumnpduDevMonEmdMasterAlarm1 | read-only | mandatory | The alarm-1 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.1.1.1.14 | ColumnpduDevMonEmdMasterAlarm2 | read-only | mandatory | The alarm-2 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.2 | NodepduDevMonEmdSlave01 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.2.1 | TablepduDevMonEmdSlave01Table | not-accessible | mandatory | Display a list of the emd information of Slave01. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.2.1.1 | RowpduDevMonEmdSlave01Entry | not-accessible | mandatory | Display a list of the emd information of Slave01. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.2.1.1.1 | ColumnpduDevMonEmdSlave01Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.2.1.1.2 | ColumnpduDevMonEmdSlave01Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.2.1.1.3 | ColumnpduDevMonEmdSlave01Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.2.1.1.4 | ColumnpduDevMonEmdSlave01Name | read-only | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.2.1.1.5 | ColumnpduDevMonEmdSlave01TempName | read-only | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.2.1.1.6 | ColumnpduDevMonEmdSlave01HumiName | read-only | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.2.1.1.7 | ColumnpduDevMonEmdSlave01Alarm1Name | read-only | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.2.1.1.8 | ColumnpduDevMonEmdSlave01Alarm2Name | read-only | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.2.1.1.9 | ColumnpduDevMonEmdSlave01Temp | read-only | mandatory | The temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.2.1.1.10 | ColumnpduDevMonEmdSlave01Humi | read-only | mandatory | The humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.2.1.1.11 | ColumnpduDevMonEmdSlave01TempSt | read-only | mandatory | The temp status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.2.1.1.12 | ColumnpduDevMonEmdSlave01HumiSt | read-only | mandatory | The humi status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.2.1.1.13 | ColumnpduDevMonEmdSlave01Alarm1 | read-only | mandatory | The alarm-1 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.2.1.1.14 | ColumnpduDevMonEmdSlave01Alarm2 | read-only | mandatory | The alarm-2 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.3 | NodepduDevMonEmdSlave02 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.3.1 | TablepduDevMonEmdSlave02Table | not-accessible | mandatory | Display a list of the emd information of Slave02. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.3.1.1 | RowpduDevMonEmdSlave02Entry | not-accessible | mandatory | Display a list of the emd information of Slave02. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.3.1.1.1 | ColumnpduDevMonEmdSlave02Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.3.1.1.2 | ColumnpduDevMonEmdSlave02Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.3.1.1.3 | ColumnpduDevMonEmdSlave02Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.3.1.1.4 | ColumnpduDevMonEmdSlave02Name | read-only | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.3.1.1.5 | ColumnpduDevMonEmdSlave02TempName | read-only | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.3.1.1.6 | ColumnpduDevMonEmdSlave02HumiName | read-only | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.3.1.1.7 | ColumnpduDevMonEmdSlave02Alarm1Name | read-only | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.3.1.1.8 | ColumnpduDevMonEmdSlave02Alarm2Name | read-only | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.3.1.1.9 | ColumnpduDevMonEmdSlave02Temp | read-only | mandatory | The temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.3.1.1.10 | ColumnpduDevMonEmdSlave02Humi | read-only | mandatory | The humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.3.1.1.11 | ColumnpduDevMonEmdSlave02TempSt | read-only | mandatory | The temp status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.3.1.1.12 | ColumnpduDevMonEmdSlave02HumiSt | read-only | mandatory | The humi status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.3.1.1.13 | ColumnpduDevMonEmdSlave02Alarm1 | read-only | mandatory | The alarm-1 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.3.1.1.14 | ColumnpduDevMonEmdSlave02Alarm2 | read-only | mandatory | The alarm-2 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.4 | NodepduDevMonEmdSlave03 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.4.1 | TablepduDevMonEmdSlave03Table | not-accessible | mandatory | Display a list of the emd information of Slave03. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.4.1.1 | RowpduDevMonEmdSlave03Entry | not-accessible | mandatory | Display a list of the emd information of Slave03. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.4.1.1.1 | ColumnpduDevMonEmdSlave03Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.4.1.1.2 | ColumnpduDevMonEmdSlave03Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.4.1.1.3 | ColumnpduDevMonEmdSlave03Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.4.1.1.4 | ColumnpduDevMonEmdSlave03Name | read-only | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.4.1.1.5 | ColumnpduDevMonEmdSlave03TempName | read-only | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.4.1.1.6 | ColumnpduDevMonEmdSlave03HumiName | read-only | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.4.1.1.7 | ColumnpduDevMonEmdSlave03Alarm1Name | read-only | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.4.1.1.8 | ColumnpduDevMonEmdSlave03Alarm2Name | read-only | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.4.1.1.9 | ColumnpduDevMonEmdSlave03Temp | read-only | mandatory | The temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.4.1.1.10 | ColumnpduDevMonEmdSlave03Humi | read-only | mandatory | The humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.4.1.1.11 | ColumnpduDevMonEmdSlave03TempSt | read-only | mandatory | The temp status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.4.1.1.12 | ColumnpduDevMonEmdSlave03HumiSt | read-only | mandatory | The humi status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.4.1.1.13 | ColumnpduDevMonEmdSlave03Alarm1 | read-only | mandatory | The alarm-1 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.4.1.1.14 | ColumnpduDevMonEmdSlave03Alarm2 | read-only | mandatory | The alarm-2 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.5 | NodepduDevMonEmdSlave04 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.5.1 | TablepduDevMonEmdSlave04Table | not-accessible | mandatory | Display a list of the emd information of Slave04. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.5.1.1 | RowpduDevMonEmdSlave04Entry | not-accessible | mandatory | Display a list of the emd information of Slave04. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.5.1.1.1 | ColumnpduDevMonEmdSlave04Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.5.1.1.2 | ColumnpduDevMonEmdSlave04Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.5.1.1.3 | ColumnpduDevMonEmdSlave04Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.5.1.1.4 | ColumnpduDevMonEmdSlave04Name | read-only | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.5.1.1.5 | ColumnpduDevMonEmdSlave04TempName | read-only | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.5.1.1.6 | ColumnpduDevMonEmdSlave04HumiName | read-only | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.5.1.1.7 | ColumnpduDevMonEmdSlave04Alarm1Name | read-only | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.5.1.1.8 | ColumnpduDevMonEmdSlave04Alarm2Name | read-only | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.5.1.1.9 | ColumnpduDevMonEmdSlave04Temp | read-only | mandatory | The temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.5.1.1.10 | ColumnpduDevMonEmdSlave04Humi | read-only | mandatory | The humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.5.1.1.11 | ColumnpduDevMonEmdSlave04TempSt | read-only | mandatory | The temp status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.5.1.1.12 | ColumnpduDevMonEmdSlave04HumiSt | read-only | mandatory | The humi status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.5.1.1.13 | ColumnpduDevMonEmdSlave04Alarm1 | read-only | mandatory | The alarm-1 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.5.1.1.14 | ColumnpduDevMonEmdSlave04Alarm2 | read-only | mandatory | The alarm-2 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.6 | NodepduDevMonEmdSlave05 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.6.1 | TablepduDevMonEmdSlave05Table | not-accessible | mandatory | Display a list of the emd information of Slave05. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.6.1.1 | RowpduDevMonEmdSlave05Entry | not-accessible | mandatory | Display a list of the emd information of Slave05. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.6.1.1.1 | ColumnpduDevMonEmdSlave05Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.6.1.1.2 | ColumnpduDevMonEmdSlave05Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.6.1.1.3 | ColumnpduDevMonEmdSlave05Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.6.1.1.4 | ColumnpduDevMonEmdSlave05Name | read-only | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.6.1.1.5 | ColumnpduDevMonEmdSlave05TempName | read-only | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.6.1.1.6 | ColumnpduDevMonEmdSlave05HumiName | read-only | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.6.1.1.7 | ColumnpduDevMonEmdSlave05Alarm1Name | read-only | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.6.1.1.8 | ColumnpduDevMonEmdSlave05Alarm2Name | read-only | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.6.1.1.9 | ColumnpduDevMonEmdSlave05Temp | read-only | mandatory | The temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.6.1.1.10 | ColumnpduDevMonEmdSlave05Humi | read-only | mandatory | The humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.6.1.1.11 | ColumnpduDevMonEmdSlave05TempSt | read-only | mandatory | The temp status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.6.1.1.12 | ColumnpduDevMonEmdSlave05HumiSt | read-only | mandatory | The humi status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.6.1.1.13 | ColumnpduDevMonEmdSlave05Alarm1 | read-only | mandatory | The alarm-1 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.6.1.1.14 | ColumnpduDevMonEmdSlave05Alarm2 | read-only | mandatory | The alarm-2 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.7 | NodepduDevMonEmdSlave06 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.7.1 | TablepduDevMonEmdSlave06Table | not-accessible | mandatory | Display a list of the emd information of Slave06. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.7.1.1 | RowpduDevMonEmdSlave06Entry | not-accessible | mandatory | Display a list of the emd information of Slave06. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.7.1.1.1 | ColumnpduDevMonEmdSlave06Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.7.1.1.2 | ColumnpduDevMonEmdSlave06Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.7.1.1.3 | ColumnpduDevMonEmdSlave06Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.7.1.1.4 | ColumnpduDevMonEmdSlave06Name | read-only | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.7.1.1.5 | ColumnpduDevMonEmdSlave06TempName | read-only | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.7.1.1.6 | ColumnpduDevMonEmdSlave06HumiName | read-only | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.7.1.1.7 | ColumnpduDevMonEmdSlave06Alarm1Name | read-only | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.7.1.1.8 | ColumnpduDevMonEmdSlave06Alarm2Name | read-only | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.7.1.1.9 | ColumnpduDevMonEmdSlave06Temp | read-only | mandatory | The temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.7.1.1.10 | ColumnpduDevMonEmdSlave06Humi | read-only | mandatory | The humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.7.1.1.11 | ColumnpduDevMonEmdSlave06TempSt | read-only | mandatory | The temp status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.7.1.1.12 | ColumnpduDevMonEmdSlave06HumiSt | read-only | mandatory | The humi status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.7.1.1.13 | ColumnpduDevMonEmdSlave06Alarm1 | read-only | mandatory | The alarm-1 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.7.1.1.14 | ColumnpduDevMonEmdSlave06Alarm2 | read-only | mandatory | The alarm-2 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.8 | NodepduDevMonEmdSlave07 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.8.1 | TablepduDevMonEmdSlave07Table | not-accessible | mandatory | Display a list of the emd information of Slave07. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.8.1.1 | RowpduDevMonEmdSlave07Entry | not-accessible | mandatory | Display a list of the emd information of Slave07. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.8.1.1.1 | ColumnpduDevMonEmdSlave07Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.8.1.1.2 | ColumnpduDevMonEmdSlave07Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.8.1.1.3 | ColumnpduDevMonEmdSlave07Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.8.1.1.4 | ColumnpduDevMonEmdSlave07Name | read-only | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.8.1.1.5 | ColumnpduDevMonEmdSlave07TempName | read-only | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.8.1.1.6 | ColumnpduDevMonEmdSlave07HumiName | read-only | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.8.1.1.7 | ColumnpduDevMonEmdSlave07Alarm1Name | read-only | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.8.1.1.8 | ColumnpduDevMonEmdSlave07Alarm2Name | read-only | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.8.1.1.9 | ColumnpduDevMonEmdSlave07Temp | read-only | mandatory | The temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.8.1.1.10 | ColumnpduDevMonEmdSlave07Humi | read-only | mandatory | The humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.8.1.1.11 | ColumnpduDevMonEmdSlave07TempSt | read-only | mandatory | The temp status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.8.1.1.12 | ColumnpduDevMonEmdSlave07HumiSt | read-only | mandatory | The humi status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.8.1.1.13 | ColumnpduDevMonEmdSlave07Alarm1 | read-only | mandatory | The alarm-1 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.8.1.1.14 | ColumnpduDevMonEmdSlave07Alarm2 | read-only | mandatory | The alarm-2 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.9 | NodepduDevMonEmdSlave08 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.9.1 | TablepduDevMonEmdSlave08Table | not-accessible | mandatory | Display a list of the emd information of Slave08. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.9.1.1 | RowpduDevMonEmdSlave08Entry | not-accessible | mandatory | Display a list of the emd information of Slave08. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.9.1.1.1 | ColumnpduDevMonEmdSlave08Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.9.1.1.2 | ColumnpduDevMonEmdSlave08Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.9.1.1.3 | ColumnpduDevMonEmdSlave08Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.9.1.1.4 | ColumnpduDevMonEmdSlave08Name | read-only | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.9.1.1.5 | ColumnpduDevMonEmdSlave08TempName | read-only | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.9.1.1.6 | ColumnpduDevMonEmdSlave08HumiName | read-only | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.9.1.1.7 | ColumnpduDevMonEmdSlave08Alarm1Name | read-only | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.9.1.1.8 | ColumnpduDevMonEmdSlave08Alarm2Name | read-only | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.9.1.1.9 | ColumnpduDevMonEmdSlave08Temp | read-only | mandatory | The temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.9.1.1.10 | ColumnpduDevMonEmdSlave08Humi | read-only | mandatory | The humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.9.1.1.11 | ColumnpduDevMonEmdSlave08TempSt | read-only | mandatory | The temp status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.9.1.1.12 | ColumnpduDevMonEmdSlave08HumiSt | read-only | mandatory | The humi status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.9.1.1.13 | ColumnpduDevMonEmdSlave08Alarm1 | read-only | mandatory | The alarm-1 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.9.1.1.14 | ColumnpduDevMonEmdSlave08Alarm2 | read-only | mandatory | The alarm-2 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.10 | NodepduDevMonEmdSlave09 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.10.1 | TablepduDevMonEmdSlave09Table | not-accessible | mandatory | Display a list of the emd information of Slave09. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.10.1.1 | RowpduDevMonEmdSlave09Entry | not-accessible | mandatory | Display a list of the emd information of Slave09. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.10.1.1.1 | ColumnpduDevMonEmdSlave09Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.10.1.1.2 | ColumnpduDevMonEmdSlave09Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.10.1.1.3 | ColumnpduDevMonEmdSlave09Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.10.1.1.4 | ColumnpduDevMonEmdSlave09Name | read-only | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.10.1.1.5 | ColumnpduDevMonEmdSlave09TempName | read-only | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.10.1.1.6 | ColumnpduDevMonEmdSlave09HumiName | read-only | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.10.1.1.7 | ColumnpduDevMonEmdSlave09Alarm1Name | read-only | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.10.1.1.8 | ColumnpduDevMonEmdSlave09Alarm2Name | read-only | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.10.1.1.9 | ColumnpduDevMonEmdSlave09Temp | read-only | mandatory | The temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.10.1.1.10 | ColumnpduDevMonEmdSlave09Humi | read-only | mandatory | The humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.10.1.1.11 | ColumnpduDevMonEmdSlave09TempSt | read-only | mandatory | The temp status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.10.1.1.12 | ColumnpduDevMonEmdSlave09HumiSt | read-only | mandatory | The humi status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.10.1.1.13 | ColumnpduDevMonEmdSlave09Alarm1 | read-only | mandatory | The alarm-1 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.10.1.1.14 | ColumnpduDevMonEmdSlave09Alarm2 | read-only | mandatory | The alarm-2 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.11 | NodepduDevMonEmdSlave10 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.11.1 | TablepduDevMonEmdSlave10Table | not-accessible | mandatory | Display a list of the emd information of Slave10. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.11.1.1 | RowpduDevMonEmdSlave10Entry | not-accessible | mandatory | Display a list of the emd information of Slave10. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.11.1.1.1 | ColumnpduDevMonEmdSlave10Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.11.1.1.2 | ColumnpduDevMonEmdSlave10Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.11.1.1.3 | ColumnpduDevMonEmdSlave10Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.11.1.1.4 | ColumnpduDevMonEmdSlave10Name | read-only | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.11.1.1.5 | ColumnpduDevMonEmdSlave10TempName | read-only | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.11.1.1.6 | ColumnpduDevMonEmdSlave10HumiName | read-only | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.11.1.1.7 | ColumnpduDevMonEmdSlave10Alarm1Name | read-only | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.11.1.1.8 | ColumnpduDevMonEmdSlave10Alarm2Name | read-only | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.11.1.1.9 | ColumnpduDevMonEmdSlave10Temp | read-only | mandatory | The temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.11.1.1.10 | ColumnpduDevMonEmdSlave10Humi | read-only | mandatory | The humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.11.1.1.11 | ColumnpduDevMonEmdSlave10TempSt | read-only | mandatory | The temp status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.11.1.1.12 | ColumnpduDevMonEmdSlave10HumiSt | read-only | mandatory | The humi status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.11.1.1.13 | ColumnpduDevMonEmdSlave10Alarm1 | read-only | mandatory | The alarm-1 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.11.1.1.14 | ColumnpduDevMonEmdSlave10Alarm2 | read-only | mandatory | The alarm-2 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.12 | NodepduDevMonEmdSlave11 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.12.1 | TablepduDevMonEmdSlave11Table | not-accessible | mandatory | Display a list of the emd information of Slave11. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.12.1.1 | RowpduDevMonEmdSlave11Entry | not-accessible | mandatory | Display a list of the emd information of Slave11. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.12.1.1.1 | ColumnpduDevMonEmdSlave11Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.12.1.1.2 | ColumnpduDevMonEmdSlave11Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.12.1.1.3 | ColumnpduDevMonEmdSlave11Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.12.1.1.4 | ColumnpduDevMonEmdSlave11Name | read-only | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.12.1.1.5 | ColumnpduDevMonEmdSlave11TempName | read-only | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.12.1.1.6 | ColumnpduDevMonEmdSlave11HumiName | read-only | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.12.1.1.7 | ColumnpduDevMonEmdSlave11Alarm1Name | read-only | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.12.1.1.8 | ColumnpduDevMonEmdSlave11Alarm2Name | read-only | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.12.1.1.9 | ColumnpduDevMonEmdSlave11Temp | read-only | mandatory | The temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.12.1.1.10 | ColumnpduDevMonEmdSlave11Humi | read-only | mandatory | The humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.12.1.1.11 | ColumnpduDevMonEmdSlave11TempSt | read-only | mandatory | The temp status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.12.1.1.12 | ColumnpduDevMonEmdSlave11HumiSt | read-only | mandatory | The humi status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.12.1.1.13 | ColumnpduDevMonEmdSlave11Alarm1 | read-only | mandatory | The alarm-1 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.12.1.1.14 | ColumnpduDevMonEmdSlave11Alarm2 | read-only | mandatory | The alarm-2 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.13 | NodepduDevMonEmdSlave12 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.13.1 | TablepduDevMonEmdSlave12Table | not-accessible | mandatory | Display a list of the emd information of Slave12. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.13.1.1 | RowpduDevMonEmdSlave12Entry | not-accessible | mandatory | Display a list of the emd information of Slave12. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.13.1.1.1 | ColumnpduDevMonEmdSlave12Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.13.1.1.2 | ColumnpduDevMonEmdSlave12Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.13.1.1.3 | ColumnpduDevMonEmdSlave12Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.13.1.1.4 | ColumnpduDevMonEmdSlave12Name | read-only | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.13.1.1.5 | ColumnpduDevMonEmdSlave12TempName | read-only | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.13.1.1.6 | ColumnpduDevMonEmdSlave12HumiName | read-only | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.13.1.1.7 | ColumnpduDevMonEmdSlave12Alarm1Name | read-only | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.13.1.1.8 | ColumnpduDevMonEmdSlave12Alarm2Name | read-only | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.13.1.1.9 | ColumnpduDevMonEmdSlave12Temp | read-only | mandatory | The temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.13.1.1.10 | ColumnpduDevMonEmdSlave12Humi | read-only | mandatory | The humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.13.1.1.11 | ColumnpduDevMonEmdSlave12TempSt | read-only | mandatory | The temp status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.13.1.1.12 | ColumnpduDevMonEmdSlave12HumiSt | read-only | mandatory | The humi status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.13.1.1.13 | ColumnpduDevMonEmdSlave12Alarm1 | read-only | mandatory | The alarm-1 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.13.1.1.14 | ColumnpduDevMonEmdSlave12Alarm2 | read-only | mandatory | The alarm-2 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.14 | NodepduDevMonEmdSlave13 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.14.1 | TablepduDevMonEmdSlave13Table | not-accessible | mandatory | Display a list of the emd information of Slave13. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.14.1.1 | RowpduDevMonEmdSlave13Entry | not-accessible | mandatory | Display a list of the emd information of Slave13. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.14.1.1.1 | ColumnpduDevMonEmdSlave13Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.14.1.1.2 | ColumnpduDevMonEmdSlave13Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.14.1.1.3 | ColumnpduDevMonEmdSlave13Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.14.1.1.4 | ColumnpduDevMonEmdSlave13Name | read-only | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.14.1.1.5 | ColumnpduDevMonEmdSlave13TempName | read-only | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.14.1.1.6 | ColumnpduDevMonEmdSlave13HumiName | read-only | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.14.1.1.7 | ColumnpduDevMonEmdSlave13Alarm1Name | read-only | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.14.1.1.8 | ColumnpduDevMonEmdSlave13Alarm2Name | read-only | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.14.1.1.9 | ColumnpduDevMonEmdSlave13Temp | read-only | mandatory | The temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.14.1.1.10 | ColumnpduDevMonEmdSlave13Humi | read-only | mandatory | The humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.14.1.1.11 | ColumnpduDevMonEmdSlave13TempSt | read-only | mandatory | The temp status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.14.1.1.12 | ColumnpduDevMonEmdSlave13HumiSt | read-only | mandatory | The humi status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.14.1.1.13 | ColumnpduDevMonEmdSlave13Alarm1 | read-only | mandatory | The alarm-1 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.14.1.1.14 | ColumnpduDevMonEmdSlave13Alarm2 | read-only | mandatory | The alarm-2 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.15 | NodepduDevMonEmdSlave14 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.15.1 | TablepduDevMonEmdSlave14Table | not-accessible | mandatory | Display a list of the emd information of Slave14. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.15.1.1 | RowpduDevMonEmdSlave14Entry | not-accessible | mandatory | Display a list of the emd information of Slave14. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.15.1.1.1 | ColumnpduDevMonEmdSlave14Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.15.1.1.2 | ColumnpduDevMonEmdSlave14Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.15.1.1.3 | ColumnpduDevMonEmdSlave14Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.15.1.1.4 | ColumnpduDevMonEmdSlave14Name | read-only | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.15.1.1.5 | ColumnpduDevMonEmdSlave14TempName | read-only | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.15.1.1.6 | ColumnpduDevMonEmdSlave14HumiName | read-only | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.15.1.1.7 | ColumnpduDevMonEmdSlave14Alarm1Name | read-only | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.15.1.1.8 | ColumnpduDevMonEmdSlave14Alarm2Name | read-only | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.15.1.1.9 | ColumnpduDevMonEmdSlave14Temp | read-only | mandatory | The temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.15.1.1.10 | ColumnpduDevMonEmdSlave14Humi | read-only | mandatory | The humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.15.1.1.11 | ColumnpduDevMonEmdSlave14TempSt | read-only | mandatory | The temp status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.15.1.1.12 | ColumnpduDevMonEmdSlave14HumiSt | read-only | mandatory | The humi status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.15.1.1.13 | ColumnpduDevMonEmdSlave14Alarm1 | read-only | mandatory | The alarm-1 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.15.1.1.14 | ColumnpduDevMonEmdSlave14Alarm2 | read-only | mandatory | The alarm-2 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.16 | NodepduDevMonEmdSlave15 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.16.1 | TablepduDevMonEmdSlave15Table | not-accessible | mandatory | Display a list of the emd information of Slave15. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.16.1.1 | RowpduDevMonEmdSlave15Entry | not-accessible | mandatory | Display a list of the emd information of Slave15. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.16.1.1.1 | ColumnpduDevMonEmdSlave15Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.16.1.1.2 | ColumnpduDevMonEmdSlave15Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.16.1.1.3 | ColumnpduDevMonEmdSlave15Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.16.1.1.4 | ColumnpduDevMonEmdSlave15Name | read-only | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.16.1.1.5 | ColumnpduDevMonEmdSlave15TempName | read-only | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.16.1.1.6 | ColumnpduDevMonEmdSlave15HumiName | read-only | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.16.1.1.7 | ColumnpduDevMonEmdSlave15Alarm1Name | read-only | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.16.1.1.8 | ColumnpduDevMonEmdSlave15Alarm2Name | read-only | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.16.1.1.9 | ColumnpduDevMonEmdSlave15Temp | read-only | mandatory | The temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.16.1.1.10 | ColumnpduDevMonEmdSlave15Humi | read-only | mandatory | The humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.16.1.1.11 | ColumnpduDevMonEmdSlave15TempSt | read-only | mandatory | The temp status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.16.1.1.12 | ColumnpduDevMonEmdSlave15HumiSt | read-only | mandatory | The humi status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.16.1.1.13 | ColumnpduDevMonEmdSlave15Alarm1 | read-only | mandatory | The alarm-1 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.2.3.16.1.1.14 | ColumnpduDevMonEmdSlave15Alarm2 | read-only | mandatory | The alarm-2 of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3 | NodepduDevMgmt | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.1 | NodepduDevMgmtInlet | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1 | TablepduDevMgmtInletTable | not-accessible | mandatory | A list to display setting of inlet of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1 | RowpduDevMgmtInletEntry | not-accessible | mandatory | A list to display setting of inlet of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.1 | ColumnpduDevMgmtInletIndex | read-only | mandatory | The index to a inlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.2 | ColumnpduDevMgmtInletName | read-write | mandatory | The name of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.3 | ColumnpduDevMgmtInletEnergyClr | read-write | mandatory | Clear energy of inlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.4 | ColumnpduDevMgmtInletOverLoadWarn | read-write | mandatory | The warning threshold of inlet load. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.5 | ColumnpduDevMgmtInletOverLoadCrit | read-write | mandatory | The critical threshold of inlet load. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.6 | ColumnpduDevMgmtInletLoadBalanceWarn | read-write | mandatory | The warning threshold of inlet load balance. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.7 | ColumnpduDevMgmtInletLoadBalanceCrit | read-write | mandatory | The critical threshold of inlet load balance. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.8 | ColumnpduDevMgmtInletOverVoltWarnPh1 | read-write | mandatory | The warning threshold of pahse1 of inlet voltage. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.9 | ColumnpduDevMgmtInletOverVoltWarnPh2 | read-write | mandatory | The warning threshold of pahse2 of inlet voltage. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.10 | ColumnpduDevMgmtInletOverVoltWarnPh3 | read-write | mandatory | The warning threshold of pahse3 of inlet voltage. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.11 | ColumnpduDevMgmtInletOverVoltCritPh1 | read-write | mandatory | The critical threshold of pahse1 of inlet voltage. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.12 | ColumnpduDevMgmtInletOverVoltCritPh2 | read-write | mandatory | The critical threshold of pahse2 of inlet voltage. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.13 | ColumnpduDevMgmtInletOverVoltCritPh3 | read-write | mandatory | The critical threshold of pahse3 of inlet voltage. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.14 | ColumnpduDevMgmtInletOverCurrTotalWarnPh1 | read-write | mandatory | The warning threshold of pahse1 of inlet total current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.15 | ColumnpduDevMgmtInletOverCurrTotalWarnPh2 | read-write | mandatory | The warning threshold of pahse2 of inlet total current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.16 | ColumnpduDevMgmtInletOverCurrTotalWarnPh3 | read-write | mandatory | The warning threshold of pahse3 of inlet total current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.17 | ColumnpduDevMgmtInletOverCurrTotalCritPh1 | read-write | mandatory | The critical threshold of pahse1 of inlet total current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.18 | ColumnpduDevMgmtInletOverCurrTotalCritPh2 | read-write | mandatory | The critical threshold of pahse2 of inlet total current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.19 | ColumnpduDevMgmtInletOverCurrTotalCritPh3 | read-write | mandatory | The critical threshold of pahse3 of inlet total current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.20 | ColumnpduDevMgmtInletOverCurrB1WarnPh1 | read-write | mandatory | The warning threshold of pahse1b1 of inlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.21 | ColumnpduDevMgmtInletOverCurrB1WarnPh2 | read-write | mandatory | The warning threshold of pahse2b1 of inlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.22 | ColumnpduDevMgmtInletOverCurrB1WarnPh3 | read-write | mandatory | The warning threshold of pahse2b1 of inlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.23 | ColumnpduDevMgmtInletOverCurrB1CritPh1 | read-write | mandatory | The critical threshold of pahse1b1 of inlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.24 | ColumnpduDevMgmtInletOverCurrB1CritPh2 | read-write | mandatory | The critical threshold of pahse2b1 of inlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.25 | ColumnpduDevMgmtInletOverCurrB1CritPh3 | read-write | mandatory | The critical threshold of pahse3b1 of inlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.26 | ColumnpduDevMgmtInletOverCurrB2WarnPh1 | read-write | mandatory | The warning threshold of pahse1b2 of inlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.27 | ColumnpduDevMgmtInletOverCurrB2WarnPh2 | read-write | mandatory | The warning threshold of pahse2b2 of inlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.28 | ColumnpduDevMgmtInletOverCurrB2WarnPh3 | read-write | mandatory | The warning threshold of pahse3b2 of inlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.29 | ColumnpduDevMgmtInletOverCurrB2CritPh1 | read-write | mandatory | The critical threshold of pahse1b2 of inlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.30 | ColumnpduDevMgmtInletOverCurrB2CritPh2 | read-write | mandatory | The critical threshold of pahse2b2 of inlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.31 | ColumnpduDevMgmtInletOverCurrB2CritPh3 | read-write | mandatory | The critical threshold of pahse3b2 of inlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.32 | ColumnpduDevMgmtInletRcmThld | read-write | mandatory | Leakage current alarm threshold. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.33 | ColumnpduDevMgmtInletOverPfB1WarnPh1 | read-write | mandatory | The warning threshold of pahse1b1 of inlet pf. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.34 | ColumnpduDevMgmtInletOverPfB1WarnPh2 | read-write | mandatory | The warning threshold of pahse2b1 of inlet pf. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.35 | ColumnpduDevMgmtInletOverPfB1WarnPh3 | read-write | mandatory | The warning threshold of pahse2b1 of inlet pf. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.36 | ColumnpduDevMgmtInletOverPfB1CritPh1 | read-write | mandatory | The critical threshold of pahse1b1 of inlet pf. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.37 | ColumnpduDevMgmtInletOverPfB1CritPh2 | read-write | mandatory | The critical threshold of pahse2b1 of inlet pf. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.38 | ColumnpduDevMgmtInletOverPfB1CritPh3 | read-write | mandatory | The critical threshold of pahse3b1 of inlet pf. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.39 | ColumnpduDevMgmtInletOverPfB2WarnPh1 | read-write | mandatory | The warning threshold of pahse1b2 of inlet pf. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.40 | ColumnpduDevMgmtInletOverPfB2WarnPh2 | read-write | mandatory | The warning threshold of pahse2b2 of inlet pf. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.41 | ColumnpduDevMgmtInletOverPfB2WarnPh3 | read-write | mandatory | The warning threshold of pahse3b2 of inlet pf. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.42 | ColumnpduDevMgmtInletOverPfB2CritPh1 | read-write | mandatory | The critical threshold of pahse1b2 of inlet pf. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.43 | ColumnpduDevMgmtInletOverPfB2CritPh2 | read-write | mandatory | The critical threshold of pahse2b2 of inlet pf. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.1.1.1.44 | ColumnpduDevMgmtInletOverPfB2CritPh3 | read-write | mandatory | The critical threshold of pahse3b2 of inlet pf. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2 | NodepduDevMgmtOutlet | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.1 | NodepduDevMgmtOutletMaster | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.1.1 | ScalarpduDevMgmtOutletMasterPortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.1.2 | TablepduDevMgmtOutletMasterPortTable | not-accessible | mandatory | Display the port information list of MasterPort. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.1.2.1 | RowpduDevMgmtOutletMasterPortEntry | not-accessible | mandatory | Display the port information list of MasterPort.. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.1.2.1.1 | ColumnpduDevMgmtOutletMasterPortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.1.2.1.2 | ColumnpduDevMgmtOutletMasterPortValid | read-only | mandatory | The online status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.1.2.1.3 | ColumnpduDevMgmtOutletMasterPortEnergyClr | read-write | mandatory | Clear energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.1.2.1.4 | ColumnpduDevMgmtOutletMasterPortName | read-write | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.1.2.1.5 | ColumnpduDevMgmtOutletMasterPortOnDelayTime | read-write | mandatory | The on delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.1.2.1.6 | ColumnpduDevMgmtOutletMasterPortOnDelayStatus | read-write | mandatory | The delay on status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.1.2.1.7 | ColumnpduDevMgmtOutletMasterPortOffDelayTime | read-write | mandatory | The off delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.1.2.1.8 | ColumnpduDevMgmtOutletMasterPortOffDelayStatus | read-write | mandatory | The delay off status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.1.2.1.9 | ColumnpduDevMgmtOutletMasterPortRebootTime | read-write | mandatory | The reboot time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.1.2.1.10 | ColumnpduDevMgmtOutletMasterPortOverCurrWarn | read-write | mandatory | The warning threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.1.2.1.11 | ColumnpduDevMgmtOutletMasterPortOverCurrCrit | read-write | mandatory | The critical threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.1.2.1.12 | ColumnpduDevMgmtOutletMasterPortOverPowerWarn | read-write | mandatory | The warning threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.1.2.1.13 | ColumnpduDevMgmtOutletMasterPortOverPowerCrit | read-write | mandatory | The critical threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.1.2.1.14 | ColumnpduDevMgmtOutletMasterPortRly | read-write | mandatory | Relay action of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.2 | NodepduDevMgmtOutletSlave01 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.2.1 | ScalarpduDevMgmtOutletSlave01PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.2.2 | TablepduDevMgmtOutletSlave01PortTable | not-accessible | mandatory | Display the port information list of Slave01Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.2.2.1 | RowpduDevMgmtOutletSlave01PortEntry | not-accessible | mandatory | Display the port information list of Slave01Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.2.2.1.1 | ColumnpduDevMgmtOutletSlave01PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.2.2.1.2 | ColumnpduDevMgmtOutletSlave01PortValid | read-only | mandatory | The online status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.2.2.1.3 | ColumnpduDevMgmtOutletSlave01PortEnergyClr | read-write | mandatory | Clear energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.2.2.1.4 | ColumnpduDevMgmtOutletSlave01PortName | read-write | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.2.2.1.5 | ColumnpduDevMgmtOutletSlave01PortOnDelayTime | read-write | mandatory | The on delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.2.2.1.6 | ColumnpduDevMgmtOutletSlave01PortOnDelayStatus | read-write | mandatory | The delay on status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.2.2.1.7 | ColumnpduDevMgmtOutletSlave01PortOffDelayTime | read-write | mandatory | The off delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.2.2.1.8 | ColumnpduDevMgmtOutletSlave01PortOffDelayStatus | read-write | mandatory | The delay off status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.2.2.1.9 | ColumnpduDevMgmtOutletSlave01PortRebootTime | read-write | mandatory | The reboot time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.2.2.1.10 | ColumnpduDevMgmtOutletSlave01PortOverCurrWarn | read-write | mandatory | The warning threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.2.2.1.11 | ColumnpduDevMgmtOutletSlave01PortOverCurrCrit | read-write | mandatory | The critical threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.2.2.1.12 | ColumnpduDevMgmtOutletSlave01PortOverPowerWarn | read-write | mandatory | The warning threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.2.2.1.13 | ColumnpduDevMgmtOutletSlave01PortOverPowerCrit | read-write | mandatory | The critical threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.2.2.1.14 | ColumnpduDevMgmtOutletSlave01PortRly | read-write | mandatory | Relay action of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.3 | NodepduDevMgmtOutletSlave02 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.3.1 | ScalarpduDevMgmtOutletSlave02PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.3.2 | TablepduDevMgmtOutletSlave02PortTable | not-accessible | mandatory | Display the port information list of Slave02Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.3.2.1 | RowpduDevMgmtOutletSlave02PortEntry | not-accessible | mandatory | Display the port information list of Slave02Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.3.2.1.1 | ColumnpduDevMgmtOutletSlave02PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.3.2.1.2 | ColumnpduDevMgmtOutletSlave02PortValid | read-only | mandatory | The online status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.3.2.1.3 | ColumnpduDevMgmtOutletSlave02PortEnergyClr | read-write | mandatory | Clear energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.3.2.1.4 | ColumnpduDevMgmtOutletSlave02PortName | read-write | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.3.2.1.5 | ColumnpduDevMgmtOutletSlave02PortOnDelayTime | read-write | mandatory | The on delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.3.2.1.6 | ColumnpduDevMgmtOutletSlave02PortOnDelayStatus | read-write | mandatory | The delay on status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.3.2.1.7 | ColumnpduDevMgmtOutletSlave02PortOffDelayTime | read-write | mandatory | The off delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.3.2.1.8 | ColumnpduDevMgmtOutletSlave02PortOffDelayStatus | read-write | mandatory | The delay off status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.3.2.1.9 | ColumnpduDevMgmtOutletSlave02PortRebootTime | read-write | mandatory | The reboot time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.3.2.1.10 | ColumnpduDevMgmtOutletSlave02PortOverCurrWarn | read-write | mandatory | The warning threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.3.2.1.11 | ColumnpduDevMgmtOutletSlave02PortOverCurrCrit | read-write | mandatory | The critical threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.3.2.1.12 | ColumnpduDevMgmtOutletSlave02PortOverPowerWarn | read-write | mandatory | The warning threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.3.2.1.13 | ColumnpduDevMgmtOutletSlave02PortOverPowerCrit | read-write | mandatory | The critical threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.3.2.1.14 | ColumnpduDevMgmtOutletSlave02PortRly | read-write | mandatory | Relay action of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.4 | NodepduDevMgmtOutletSlave03 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.4.1 | ScalarpduDevMgmtOutletSlave03PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.4.2 | TablepduDevMgmtOutletSlave03PortTable | not-accessible | mandatory | Display the port information list of Slave03Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.4.2.1 | RowpduDevMgmtOutletSlave03PortEntry | not-accessible | mandatory | Display the port information list of Slave03Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.4.2.1.1 | ColumnpduDevMgmtOutletSlave03PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.4.2.1.2 | ColumnpduDevMgmtOutletSlave03PortValid | read-only | mandatory | The online status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.4.2.1.3 | ColumnpduDevMgmtOutletSlave03PortEnergyClr | read-write | mandatory | Clear energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.4.2.1.4 | ColumnpduDevMgmtOutletSlave03PortName | read-write | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.4.2.1.5 | ColumnpduDevMgmtOutletSlave03PortOnDelayTime | read-write | mandatory | The on delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.4.2.1.6 | ColumnpduDevMgmtOutletSlave03PortOnDelayStatus | read-write | mandatory | The delay on status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.4.2.1.7 | ColumnpduDevMgmtOutletSlave03PortOffDelayTime | read-write | mandatory | The off delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.4.2.1.8 | ColumnpduDevMgmtOutletSlave03PortOffDelayStatus | read-write | mandatory | The delay off status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.4.2.1.9 | ColumnpduDevMgmtOutletSlave03PortRebootTime | read-write | mandatory | The reboot time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.4.2.1.10 | ColumnpduDevMgmtOutletSlave03PortOverCurrWarn | read-write | mandatory | The warning threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.4.2.1.11 | ColumnpduDevMgmtOutletSlave03PortOverCurrCrit | read-write | mandatory | The critical threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.4.2.1.12 | ColumnpduDevMgmtOutletSlave03PortOverPowerWarn | read-write | mandatory | The warning threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.4.2.1.13 | ColumnpduDevMgmtOutletSlave03PortOverPowerCrit | read-write | mandatory | The critical threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.4.2.1.14 | ColumnpduDevMgmtOutletSlave03PortRly | read-write | mandatory | Relay action of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.5 | NodepduDevMgmtOutletSlave04 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.5.1 | ScalarpduDevMgmtOutletSlave04PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.5.2 | TablepduDevMgmtOutletSlave04PortTable | not-accessible | mandatory | Display the port information list of Slave04Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.5.2.1 | RowpduDevMgmtOutletSlave04PortEntry | not-accessible | mandatory | Display the port information list of Slave04Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.5.2.1.1 | ColumnpduDevMgmtOutletSlave04PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.5.2.1.2 | ColumnpduDevMgmtOutletSlave04PortValid | read-only | mandatory | The online status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.5.2.1.3 | ColumnpduDevMgmtOutletSlave04PortEnergyClr | read-write | mandatory | Clear energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.5.2.1.4 | ColumnpduDevMgmtOutletSlave04PortName | read-write | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.5.2.1.5 | ColumnpduDevMgmtOutletSlave04PortOnDelayTime | read-write | mandatory | The on delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.5.2.1.6 | ColumnpduDevMgmtOutletSlave04PortOnDelayStatus | read-write | mandatory | The delay on status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.5.2.1.7 | ColumnpduDevMgmtOutletSlave04PortOffDelayTime | read-write | mandatory | The off delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.5.2.1.8 | ColumnpduDevMgmtOutletSlave04PortOffDelayStatus | read-write | mandatory | The delay off status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.5.2.1.9 | ColumnpduDevMgmtOutletSlave04PortRebootTime | read-write | mandatory | The reboot time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.5.2.1.10 | ColumnpduDevMgmtOutletSlave04PortOverCurrWarn | read-write | mandatory | The warning threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.5.2.1.11 | ColumnpduDevMgmtOutletSlave04PortOverCurrCrit | read-write | mandatory | The critical threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.5.2.1.12 | ColumnpduDevMgmtOutletSlave04PortOverPowerWarn | read-write | mandatory | The warning threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.5.2.1.13 | ColumnpduDevMgmtOutletSlave04PortOverPowerCrit | read-write | mandatory | The critical threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.5.2.1.14 | ColumnpduDevMgmtOutletSlave04PortRly | read-write | mandatory | Relay action of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.6 | NodepduDevMgmtOutletSlave05 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.6.1 | ScalarpduDevMgmtOutletSlave05PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.6.2 | TablepduDevMgmtOutletSlave05PortTable | not-accessible | mandatory | Display the port information list of Slave05Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.6.2.1 | RowpduDevMgmtOutletSlave05PortEntry | not-accessible | mandatory | Display the port information list of Slave05Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.6.2.1.1 | ColumnpduDevMgmtOutletSlave05PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.6.2.1.2 | ColumnpduDevMgmtOutletSlave05PortValid | read-only | mandatory | The online status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.6.2.1.3 | ColumnpduDevMgmtOutletSlave05PortEnergyClr | read-write | mandatory | Clear energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.6.2.1.4 | ColumnpduDevMgmtOutletSlave05PortName | read-write | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.6.2.1.5 | ColumnpduDevMgmtOutletSlave05PortOnDelayTime | read-write | mandatory | The on delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.6.2.1.6 | ColumnpduDevMgmtOutletSlave05PortOnDelayStatus | read-write | mandatory | The delay on status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.6.2.1.7 | ColumnpduDevMgmtOutletSlave05PortOffDelayTime | read-write | mandatory | The off delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.6.2.1.8 | ColumnpduDevMgmtOutletSlave05PortOffDelayStatus | read-write | mandatory | The delay off status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.6.2.1.9 | ColumnpduDevMgmtOutletSlave05PortRebootTime | read-write | mandatory | The reboot time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.6.2.1.10 | ColumnpduDevMgmtOutletSlave05PortOverCurrWarn | read-write | mandatory | The warning threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.6.2.1.11 | ColumnpduDevMgmtOutletSlave05PortOverCurrCrit | read-write | mandatory | The critical threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.6.2.1.12 | ColumnpduDevMgmtOutletSlave05PortOverPowerWarn | read-write | mandatory | The warning threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.6.2.1.13 | ColumnpduDevMgmtOutletSlave05PortOverPowerCrit | read-write | mandatory | The critical threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.6.2.1.14 | ColumnpduDevMgmtOutletSlave05PortRly | read-write | mandatory | Relay action of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.7 | NodepduDevMgmtOutletSlave06 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.7.1 | ScalarpduDevMgmtOutletSlave06PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.7.2 | TablepduDevMgmtOutletSlave06PortTable | not-accessible | mandatory | Display the port information list of Slave06Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.7.2.1 | RowpduDevMgmtOutletSlave06PortEntry | not-accessible | mandatory | Display the port information list of Slave06Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.7.2.1.1 | ColumnpduDevMgmtOutletSlave06PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.7.2.1.2 | ColumnpduDevMgmtOutletSlave06PortValid | read-only | mandatory | The online status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.7.2.1.3 | ColumnpduDevMgmtOutletSlave06PortEnergyClr | read-write | mandatory | Clear energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.7.2.1.4 | ColumnpduDevMgmtOutletSlave06PortName | read-write | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.7.2.1.5 | ColumnpduDevMgmtOutletSlave06PortOnDelayTime | read-write | mandatory | The on delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.7.2.1.6 | ColumnpduDevMgmtOutletSlave06PortOnDelayStatus | read-write | mandatory | The delay on status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.7.2.1.7 | ColumnpduDevMgmtOutletSlave06PortOffDelayTime | read-write | mandatory | The off delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.7.2.1.8 | ColumnpduDevMgmtOutletSlave06PortOffDelayStatus | read-write | mandatory | The delay off status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.7.2.1.9 | ColumnpduDevMgmtOutletSlave06PortRebootTime | read-write | mandatory | The reboot time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.7.2.1.10 | ColumnpduDevMgmtOutletSlave06PortOverCurrWarn | read-write | mandatory | The warning threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.7.2.1.11 | ColumnpduDevMgmtOutletSlave06PortOverCurrCrit | read-write | mandatory | The critical threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.7.2.1.12 | ColumnpduDevMgmtOutletSlave06PortOverPowerWarn | read-write | mandatory | The warning threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.7.2.1.13 | ColumnpduDevMgmtOutletSlave06PortOverPowerCrit | read-write | mandatory | The critical threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.7.2.1.14 | ColumnpduDevMgmtOutletSlave06PortRly | read-write | mandatory | Relay action of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.8 | NodepduDevMgmtOutletSlave07 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.8.1 | ScalarpduDevMgmtOutletSlave07PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.8.2 | TablepduDevMgmtOutletSlave07PortTable | not-accessible | mandatory | Display the port information list of Slave07Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.8.2.1 | RowpduDevMgmtOutletSlave07PortEntry | not-accessible | mandatory | Display the port information list of Slave07Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.8.2.1.1 | ColumnpduDevMgmtOutletSlave07PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.8.2.1.2 | ColumnpduDevMgmtOutletSlave07PortValid | read-only | mandatory | The online status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.8.2.1.3 | ColumnpduDevMgmtOutletSlave07PortEnergyClr | read-write | mandatory | Clear energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.8.2.1.4 | ColumnpduDevMgmtOutletSlave07PortName | read-write | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.8.2.1.5 | ColumnpduDevMgmtOutletSlave07PortOnDelayTime | read-write | mandatory | The on delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.8.2.1.6 | ColumnpduDevMgmtOutletSlave07PortOnDelayStatus | read-write | mandatory | The delay on status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.8.2.1.7 | ColumnpduDevMgmtOutletSlave07PortOffDelayTime | read-write | mandatory | The off delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.8.2.1.8 | ColumnpduDevMgmtOutletSlave07PortOffDelayStatus | read-write | mandatory | The delay off status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.8.2.1.9 | ColumnpduDevMgmtOutletSlave07PortRebootTime | read-write | mandatory | The reboot time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.8.2.1.10 | ColumnpduDevMgmtOutletSlave07PortOverCurrWarn | read-write | mandatory | The warning threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.8.2.1.11 | ColumnpduDevMgmtOutletSlave07PortOverCurrCrit | read-write | mandatory | The critical threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.8.2.1.12 | ColumnpduDevMgmtOutletSlave07PortOverPowerWarn | read-write | mandatory | The warning threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.8.2.1.13 | ColumnpduDevMgmtOutletSlave07PortOverPowerCrit | read-write | mandatory | The critical threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.8.2.1.14 | ColumnpduDevMgmtOutletSlave07PortRly | read-write | mandatory | Relay action of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.9 | NodepduDevMgmtOutletSlave08 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.9.1 | ScalarpduDevMgmtOutletSlave08PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.9.2 | TablepduDevMgmtOutletSlave08PortTable | not-accessible | mandatory | Display the port information list of Slave08Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.9.2.1 | RowpduDevMgmtOutletSlave08PortEntry | not-accessible | mandatory | Display the port information list of Slave08Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.9.2.1.1 | ColumnpduDevMgmtOutletSlave08PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.9.2.1.2 | ColumnpduDevMgmtOutletSlave08PortValid | read-only | mandatory | The online status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.9.2.1.3 | ColumnpduDevMgmtOutletSlave08PortEnergyClr | read-write | mandatory | Clear energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.9.2.1.4 | ColumnpduDevMgmtOutletSlave08PortName | read-write | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.9.2.1.5 | ColumnpduDevMgmtOutletSlave08PortOnDelayTime | read-write | mandatory | The on delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.9.2.1.6 | ColumnpduDevMgmtOutletSlave08PortOnDelayStatus | read-write | mandatory | The delay on status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.9.2.1.7 | ColumnpduDevMgmtOutletSlave08PortOffDelayTime | read-write | mandatory | The off delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.9.2.1.8 | ColumnpduDevMgmtOutletSlave08PortOffDelayStatus | read-write | mandatory | The delay off status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.9.2.1.9 | ColumnpduDevMgmtOutletSlave08PortRebootTime | read-write | mandatory | The reboot time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.9.2.1.10 | ColumnpduDevMgmtOutletSlave08PortOverCurrWarn | read-write | mandatory | The warning threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.9.2.1.11 | ColumnpduDevMgmtOutletSlave08PortOverCurrCrit | read-write | mandatory | The critical threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.9.2.1.12 | ColumnpduDevMgmtOutletSlave08PortOverPowerWarn | read-write | mandatory | The warning threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.9.2.1.13 | ColumnpduDevMgmtOutletSlave08PortOverPowerCrit | read-write | mandatory | The critical threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.9.2.1.14 | ColumnpduDevMgmtOutletSlave08PortRly | read-write | mandatory | Relay action of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.10 | NodepduDevMgmtOutletSlave09 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.10.1 | ScalarpduDevMgmtOutletSlave09PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.10.2 | TablepduDevMgmtOutletSlave09PortTable | not-accessible | mandatory | Display the port information list of Slave09Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.10.2.1 | RowpduDevMgmtOutletSlave09PortEntry | not-accessible | mandatory | Display the port information list of Slave09Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.10.2.1.1 | ColumnpduDevMgmtOutletSlave09PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.10.2.1.2 | ColumnpduDevMgmtOutletSlave09PortValid | read-only | mandatory | The online status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.10.2.1.3 | ColumnpduDevMgmtOutletSlave09PortEnergyClr | read-write | mandatory | Clear energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.10.2.1.4 | ColumnpduDevMgmtOutletSlave09PortName | read-write | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.10.2.1.5 | ColumnpduDevMgmtOutletSlave09PortOnDelayTime | read-write | mandatory | The on delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.10.2.1.6 | ColumnpduDevMgmtOutletSlave09PortOnDelayStatus | read-write | mandatory | The delay on status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.10.2.1.7 | ColumnpduDevMgmtOutletSlave09PortOffDelayTime | read-write | mandatory | The off delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.10.2.1.8 | ColumnpduDevMgmtOutletSlave09PortOffDelayStatus | read-write | mandatory | The delay off status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.10.2.1.9 | ColumnpduDevMgmtOutletSlave09PortRebootTime | read-write | mandatory | The reboot time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.10.2.1.10 | ColumnpduDevMgmtOutletSlave09PortOverCurrWarn | read-write | mandatory | The warning threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.10.2.1.11 | ColumnpduDevMgmtOutletSlave09PortOverCurrCrit | read-write | mandatory | The critical threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.10.2.1.12 | ColumnpduDevMgmtOutletSlave09PortOverPowerWarn | read-write | mandatory | The warning threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.10.2.1.13 | ColumnpduDevMgmtOutletSlave09PortOverPowerCrit | read-write | mandatory | The critical threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.10.2.1.14 | ColumnpduDevMgmtOutletSlave09PortRly | read-write | mandatory | Relay action of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.11 | NodepduDevMgmtOutletSlave10 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.11.1 | ScalarpduDevMgmtOutletSlave10PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.11.2 | TablepduDevMgmtOutletSlave10PortTable | not-accessible | mandatory | Display the port information list of Slave10Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.11.2.1 | RowpduDevMgmtOutletSlave10PortEntry | not-accessible | mandatory | Display the port information list of Slave10Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.11.2.1.1 | ColumnpduDevMgmtOutletSlave10PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.11.2.1.2 | ColumnpduDevMgmtOutletSlave10PortValid | read-only | mandatory | The online status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.11.2.1.3 | ColumnpduDevMgmtOutletSlave10PortEnergyClr | read-write | mandatory | Clear energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.11.2.1.4 | ColumnpduDevMgmtOutletSlave10PortName | read-write | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.11.2.1.5 | ColumnpduDevMgmtOutletSlave10PortOnDelayTime | read-write | mandatory | The on delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.11.2.1.6 | ColumnpduDevMgmtOutletSlave10PortOnDelayStatus | read-write | mandatory | The delay on status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.11.2.1.7 | ColumnpduDevMgmtOutletSlave10PortOffDelayTime | read-write | mandatory | The off delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.11.2.1.8 | ColumnpduDevMgmtOutletSlave10PortOffDelayStatus | read-write | mandatory | The delay off status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.11.2.1.9 | ColumnpduDevMgmtOutletSlave10PortRebootTime | read-write | mandatory | The reboot time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.11.2.1.10 | ColumnpduDevMgmtOutletSlave10PortOverCurrWarn | read-write | mandatory | The warning threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.11.2.1.11 | ColumnpduDevMgmtOutletSlave10PortOverCurrCrit | read-write | mandatory | The critical threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.11.2.1.12 | ColumnpduDevMgmtOutletSlave10PortOverPowerWarn | read-write | mandatory | The warning threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.11.2.1.13 | ColumnpduDevMgmtOutletSlave10PortOverPowerCrit | read-write | mandatory | The critical threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.11.2.1.14 | ColumnpduDevMgmtOutletSlave10PortRly | read-write | mandatory | Relay action of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.12 | NodepduDevMgmtOutletSlave11 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.12.1 | ScalarpduDevMgmtOutletSlave11PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.12.2 | TablepduDevMgmtOutletSlave11PortTable | not-accessible | mandatory | Display the port information list of Slave11Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.12.2.1 | RowpduDevMgmtOutletSlave11PortEntry | not-accessible | mandatory | Display the port information list of Slave11Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.12.2.1.1 | ColumnpduDevMgmtOutletSlave11PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.12.2.1.2 | ColumnpduDevMgmtOutletSlave11PortValid | read-only | mandatory | The online status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.12.2.1.3 | ColumnpduDevMgmtOutletSlave11PortEnergyClr | read-write | mandatory | Clear energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.12.2.1.4 | ColumnpduDevMgmtOutletSlave11PortName | read-write | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.12.2.1.5 | ColumnpduDevMgmtOutletSlave11PortOnDelayTime | read-write | mandatory | The on delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.12.2.1.6 | ColumnpduDevMgmtOutletSlave11PortOnDelayStatus | read-write | mandatory | The delay on status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.12.2.1.7 | ColumnpduDevMgmtOutletSlave11PortOffDelayTime | read-write | mandatory | The off delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.12.2.1.8 | ColumnpduDevMgmtOutletSlave11PortOffDelayStatus | read-write | mandatory | The delay off status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.12.2.1.9 | ColumnpduDevMgmtOutletSlave11PortRebootTime | read-write | mandatory | The reboot time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.12.2.1.10 | ColumnpduDevMgmtOutletSlave11PortOverCurrWarn | read-write | mandatory | The warning threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.12.2.1.11 | ColumnpduDevMgmtOutletSlave11PortOverCurrCrit | read-write | mandatory | The critical threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.12.2.1.12 | ColumnpduDevMgmtOutletSlave11PortOverPowerWarn | read-write | mandatory | The warning threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.12.2.1.13 | ColumnpduDevMgmtOutletSlave11PortOverPowerCrit | read-write | mandatory | The critical threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.12.2.1.14 | ColumnpduDevMgmtOutletSlave11PortRly | read-write | mandatory | Relay action of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.13 | NodepduDevMgmtOutletSlave12 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.13.1 | ScalarpduDevMgmtOutletSlave12PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.13.2 | TablepduDevMgmtOutletSlave12PortTable | not-accessible | mandatory | Display the port information list of Slave12Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.13.2.1 | RowpduDevMgmtOutletSlave12PortEntry | not-accessible | mandatory | Display the port information list of Slave12Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.13.2.1.1 | ColumnpduDevMgmtOutletSlave12PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.13.2.1.2 | ColumnpduDevMgmtOutletSlave12PortValid | read-only | mandatory | The online status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.13.2.1.3 | ColumnpduDevMgmtOutletSlave12PortEnergyClr | read-write | mandatory | Clear energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.13.2.1.4 | ColumnpduDevMgmtOutletSlave12PortName | read-write | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.13.2.1.5 | ColumnpduDevMgmtOutletSlave12PortOnDelayTime | read-write | mandatory | The on delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.13.2.1.6 | ColumnpduDevMgmtOutletSlave12PortOnDelayStatus | read-write | mandatory | The delay on status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.13.2.1.7 | ColumnpduDevMgmtOutletSlave12PortOffDelayTime | read-write | mandatory | The off delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.13.2.1.8 | ColumnpduDevMgmtOutletSlave12PortOffDelayStatus | read-write | mandatory | The delay off status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.13.2.1.9 | ColumnpduDevMgmtOutletSlave12PortRebootTime | read-write | mandatory | The reboot time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.13.2.1.10 | ColumnpduDevMgmtOutletSlave12PortOverCurrWarn | read-write | mandatory | The warning threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.13.2.1.11 | ColumnpduDevMgmtOutletSlave12PortOverCurrCrit | read-write | mandatory | The critical threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.13.2.1.12 | ColumnpduDevMgmtOutletSlave12PortOverPowerWarn | read-write | mandatory | The warning threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.13.2.1.13 | ColumnpduDevMgmtOutletSlave12PortOverPowerCrit | read-write | mandatory | The critical threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.13.2.1.14 | ColumnpduDevMgmtOutletSlave12PortRly | read-write | mandatory | Relay action of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.14 | NodepduDevMgmtOutletSlave13 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.14.1 | ScalarpduDevMgmtOutletSlave13PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.14.2 | TablepduDevMgmtOutletSlave13PortTable | not-accessible | mandatory | Display the port information list of Slave13Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.14.2.1 | RowpduDevMgmtOutletSlave13PortEntry | not-accessible | mandatory | Display the port information list of Slave13Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.14.2.1.1 | ColumnpduDevMgmtOutletSlave13PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.14.2.1.2 | ColumnpduDevMgmtOutletSlave13PortValid | read-only | mandatory | The online status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.14.2.1.3 | ColumnpduDevMgmtOutletSlave13PortEnergyClr | read-write | mandatory | Clear energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.14.2.1.4 | ColumnpduDevMgmtOutletSlave13PortName | read-write | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.14.2.1.5 | ColumnpduDevMgmtOutletSlave13PortOnDelayTime | read-write | mandatory | The on delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.14.2.1.6 | ColumnpduDevMgmtOutletSlave13PortOnDelayStatus | read-write | mandatory | The delay on status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.14.2.1.7 | ColumnpduDevMgmtOutletSlave13PortOffDelayTime | read-write | mandatory | The off delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.14.2.1.8 | ColumnpduDevMgmtOutletSlave13PortOffDelayStatus | read-write | mandatory | The delay off status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.14.2.1.9 | ColumnpduDevMgmtOutletSlave13PortRebootTime | read-write | mandatory | The reboot time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.14.2.1.10 | ColumnpduDevMgmtOutletSlave13PortOverCurrWarn | read-write | mandatory | The warning threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.14.2.1.11 | ColumnpduDevMgmtOutletSlave13PortOverCurrCrit | read-write | mandatory | The critical threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.14.2.1.12 | ColumnpduDevMgmtOutletSlave13PortOverPowerWarn | read-write | mandatory | The warning threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.14.2.1.13 | ColumnpduDevMgmtOutletSlave13PortOverPowerCrit | read-write | mandatory | The critical threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.14.2.1.14 | ColumnpduDevMgmtOutletSlave13PortRly | read-write | mandatory | Relay action of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.15 | NodepduDevMgmtOutletSlave14 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.15.1 | ScalarpduDevMgmtOutletSlave14PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.15.2 | TablepduDevMgmtOutletSlave14PortTable | not-accessible | mandatory | Display the port information list of Slave14Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.15.2.1 | RowpduDevMgmtOutletSlave14PortEntry | not-accessible | mandatory | Display the port information list of Slave14Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.15.2.1.1 | ColumnpduDevMgmtOutletSlave14PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.15.2.1.2 | ColumnpduDevMgmtOutletSlave14PortValid | read-only | mandatory | The online status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.15.2.1.3 | ColumnpduDevMgmtOutletSlave14PortEnergyClr | read-write | mandatory | Clear energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.15.2.1.4 | ColumnpduDevMgmtOutletSlave14PortName | read-write | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.15.2.1.5 | ColumnpduDevMgmtOutletSlave14PortOnDelayTime | read-write | mandatory | The on delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.15.2.1.6 | ColumnpduDevMgmtOutletSlave14PortOnDelayStatus | read-write | mandatory | The delay on status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.15.2.1.7 | ColumnpduDevMgmtOutletSlave14PortOffDelayTime | read-write | mandatory | The off delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.15.2.1.8 | ColumnpduDevMgmtOutletSlave14PortOffDelayStatus | read-write | mandatory | The delay off status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.15.2.1.9 | ColumnpduDevMgmtOutletSlave14PortRebootTime | read-write | mandatory | The reboot time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.15.2.1.10 | ColumnpduDevMgmtOutletSlave14PortOverCurrWarn | read-write | mandatory | The warning threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.15.2.1.11 | ColumnpduDevMgmtOutletSlave14PortOverCurrCrit | read-write | mandatory | The critical threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.15.2.1.12 | ColumnpduDevMgmtOutletSlave14PortOverPowerWarn | read-write | mandatory | The warning threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.15.2.1.13 | ColumnpduDevMgmtOutletSlave14PortOverPowerCrit | read-write | mandatory | The critical threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.15.2.1.14 | ColumnpduDevMgmtOutletSlave14PortRly | read-write | mandatory | Relay action of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.16 | NodepduDevMgmtOutletSlave15 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.16.1 | ScalarpduDevMgmtOutletSlave15PortSize | read-only | mandatory | The port size of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.16.2 | TablepduDevMgmtOutletSlave15PortTable | not-accessible | mandatory | Display the port information list of Slave15Port. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.16.2.1 | RowpduDevMgmtOutletSlave15PortEntry | not-accessible | mandatory | Display the port information list of Slave15Port.. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.16.2.1.1 | ColumnpduDevMgmtOutletSlave15PortIndex | read-only | mandatory | The index to a outlet entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.16.2.1.2 | ColumnpduDevMgmtOutletSlave15PortValid | read-only | mandatory | The online status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.16.2.1.3 | ColumnpduDevMgmtOutletSlave15PortEnergyClr | read-write | mandatory | Clear energy of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.16.2.1.4 | ColumnpduDevMgmtOutletSlave15PortName | read-write | mandatory | The name of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.16.2.1.5 | ColumnpduDevMgmtOutletSlave15PortOnDelayTime | read-write | mandatory | The on delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.16.2.1.6 | ColumnpduDevMgmtOutletSlave15PortOnDelayStatus | read-write | mandatory | The delay on status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.16.2.1.7 | ColumnpduDevMgmtOutletSlave15PortOffDelayTime | read-write | mandatory | The off delay of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.16.2.1.8 | ColumnpduDevMgmtOutletSlave15PortOffDelayStatus | read-write | mandatory | The delay off status of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.16.2.1.9 | ColumnpduDevMgmtOutletSlave15PortRebootTime | read-write | mandatory | The reboot time of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.16.2.1.10 | ColumnpduDevMgmtOutletSlave15PortOverCurrWarn | read-write | mandatory | The warning threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.16.2.1.11 | ColumnpduDevMgmtOutletSlave15PortOverCurrCrit | read-write | mandatory | The critical threshold of outlet current. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.16.2.1.12 | ColumnpduDevMgmtOutletSlave15PortOverPowerWarn | read-write | mandatory | The warning threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.16.2.1.13 | ColumnpduDevMgmtOutletSlave15PortOverPowerCrit | read-write | mandatory | The critical threshold of outlet power. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.2.16.2.1.14 | ColumnpduDevMgmtOutletSlave15PortRly | read-write | mandatory | Relay action of outlet. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3 | NodepduDevMgmtEmd | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.1 | NodepduDevMgmtEmdMaster | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.1.1 | TablepduDevMgmtEmdMasterTable | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.1.1.1 | RowpduDevMgmtEmdMasterEntry | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.1.1.1.1 | ColumnpduDevMgmtEmdMasterIndex | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.1.1.1.2 | ColumnpduDevMgmtEmdMasterValid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.1.1.1.3 | ColumnpduDevMgmtEmdMasterType | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.1.1.1.4 | ColumnpduDevMgmtEmdMasterName | read-write | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.1.1.1.5 | ColumnpduDevMgmtEmdMasterTempName | read-write | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.1.1.1.6 | ColumnpduDevMgmtEmdMasterHumiName | read-write | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.1.1.1.7 | ColumnpduDevMgmtEmdMasterAlarm1Name | read-write | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.1.1.1.8 | ColumnpduDevMgmtEmdMasterAlarm2Name | read-write | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.1.1.1.9 | ColumnpduDevMgmtEmdMasterTempLowWarn | read-write | mandatory | The low warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.1.1.1.10 | ColumnpduDevMgmtEmdMasterTempLowCrit | read-write | mandatory | The low critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.1.1.1.11 | ColumnpduDevMgmtEmdMasterTempHighWarn | read-write | mandatory | The high warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.1.1.1.12 | ColumnpduDevMgmtEmdMasterTempHighCrit | read-write | mandatory | The high critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.1.1.1.13 | ColumnpduDevMgmtEmdMasterTempCali | read-write | mandatory | The ofset of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.1.1.1.15 | ColumnpduDevMgmtEmdMasterHumiLowWarn | read-write | mandatory | The low warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.1.1.1.16 | ColumnpduDevMgmtEmdMasterHumiLowCrit | read-write | mandatory | The low critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.1.1.1.17 | ColumnpduDevMgmtEmdMasterHumiHighWarn | read-write | mandatory | The high warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.1.1.1.18 | ColumnpduDevMgmtEmdMasterHumiHighCrit | read-write | mandatory | The high critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.1.1.1.19 | ColumnpduDevMgmtEmdMasterHumiCali | read-write | mandatory | The ofset of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.1.1.1.21 | ColumnpduDevMgmtEmdMasterAlarm1Setup | read-write | mandatory | The alarm-1 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.1.1.1.22 | ColumnpduDevMgmtEmdMasterAlarm2Setup | read-write | mandatory | The alarm-2 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.2 | NodepduDevMgmtEmdSlave01 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.2.1 | TablepduDevMgmtEmdSlave01Table | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.2.1.1 | RowpduDevMgmtEmdSlave01Entry | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.2.1.1.1 | ColumnpduDevMgmtEmdSlave01Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.2.1.1.2 | ColumnpduDevMgmtEmdSlave01Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.2.1.1.3 | ColumnpduDevMgmtEmdSlave01Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.2.1.1.4 | ColumnpduDevMgmtEmdSlave01Name | read-write | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.2.1.1.5 | ColumnpduDevMgmtEmdSlave01TempName | read-write | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.2.1.1.6 | ColumnpduDevMgmtEmdSlave01HumiName | read-write | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.2.1.1.7 | ColumnpduDevMgmtEmdSlave01Alarm1Name | read-write | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.2.1.1.8 | ColumnpduDevMgmtEmdSlave01Alarm2Name | read-write | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.2.1.1.9 | ColumnpduDevMgmtEmdSlave01TempLowWarn | read-write | mandatory | The low warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.2.1.1.10 | ColumnpduDevMgmtEmdSlave01TempLowCrit | read-write | mandatory | The low critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.2.1.1.11 | ColumnpduDevMgmtEmdSlave01TempHighWarn | read-write | mandatory | The high warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.2.1.1.12 | ColumnpduDevMgmtEmdSlave01TempHighCrit | read-write | mandatory | The high critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.2.1.1.13 | ColumnpduDevMgmtEmdSlave01TempCali | read-write | mandatory | The ofset of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.2.1.1.15 | ColumnpduDevMgmtEmdSlave01HumiLowWarn | read-write | mandatory | The low warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.2.1.1.16 | ColumnpduDevMgmtEmdSlave01HumiLowCrit | read-write | mandatory | The low critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.2.1.1.17 | ColumnpduDevMgmtEmdSlave01HumiHighWarn | read-write | mandatory | The high warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.2.1.1.18 | ColumnpduDevMgmtEmdSlave01HumiHighCrit | read-write | mandatory | The high critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.2.1.1.19 | ColumnpduDevMgmtEmdSlave01HumiCali | read-write | mandatory | The ofset of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.2.1.1.21 | ColumnpduDevMgmtEmdSlave01Alarm1Setup | read-write | mandatory | The alarm-1 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.2.1.1.22 | ColumnpduDevMgmtEmdSlave01Alarm2Setup | read-write | mandatory | The alarm-2 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.3 | NodepduDevMgmtEmdSlave02 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.3.1 | TablepduDevMgmtEmdSlave02Table | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.3.1.1 | RowpduDevMgmtEmdSlave02Entry | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.3.1.1.1 | ColumnpduDevMgmtEmdSlave02Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.3.1.1.2 | ColumnpduDevMgmtEmdSlave02Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.3.1.1.3 | ColumnpduDevMgmtEmdSlave02Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.3.1.1.4 | ColumnpduDevMgmtEmdSlave02Name | read-write | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.3.1.1.5 | ColumnpduDevMgmtEmdSlave02TempName | read-write | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.3.1.1.6 | ColumnpduDevMgmtEmdSlave02HumiName | read-write | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.3.1.1.7 | ColumnpduDevMgmtEmdSlave02Alarm1Name | read-write | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.3.1.1.8 | ColumnpduDevMgmtEmdSlave02Alarm2Name | read-write | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.3.1.1.9 | ColumnpduDevMgmtEmdSlave02TempLowWarn | read-write | mandatory | The low warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.3.1.1.10 | ColumnpduDevMgmtEmdSlave02TempLowCrit | read-write | mandatory | The low critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.3.1.1.11 | ColumnpduDevMgmtEmdSlave02TempHighWarn | read-write | mandatory | The high warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.3.1.1.12 | ColumnpduDevMgmtEmdSlave02TempHighCrit | read-write | mandatory | The high critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.3.1.1.13 | ColumnpduDevMgmtEmdSlave02TempCali | read-write | mandatory | The ofset of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.3.1.1.15 | ColumnpduDevMgmtEmdSlave02HumiLowWarn | read-write | mandatory | The low warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.3.1.1.16 | ColumnpduDevMgmtEmdSlave02HumiLowCrit | read-write | mandatory | The low critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.3.1.1.17 | ColumnpduDevMgmtEmdSlave02HumiHighWarn | read-write | mandatory | The high warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.3.1.1.18 | ColumnpduDevMgmtEmdSlave02HumiHighCrit | read-write | mandatory | The high critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.3.1.1.19 | ColumnpduDevMgmtEmdSlave02HumiCali | read-write | mandatory | The ofset of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.3.1.1.21 | ColumnpduDevMgmtEmdSlave02Alarm1Setup | read-write | mandatory | The alarm-1 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.3.1.1.22 | ColumnpduDevMgmtEmdSlave02Alarm2Setup | read-write | mandatory | The alarm-2 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.4 | NodepduDevMgmtEmdSlave03 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.4.1 | TablepduDevMgmtEmdSlave03Table | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.4.1.1 | RowpduDevMgmtEmdSlave03Entry | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.4.1.1.1 | ColumnpduDevMgmtEmdSlave03Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.4.1.1.2 | ColumnpduDevMgmtEmdSlave03Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.4.1.1.3 | ColumnpduDevMgmtEmdSlave03Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.4.1.1.4 | ColumnpduDevMgmtEmdSlave03Name | read-write | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.4.1.1.5 | ColumnpduDevMgmtEmdSlave03TempName | read-write | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.4.1.1.6 | ColumnpduDevMgmtEmdSlave03HumiName | read-write | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.4.1.1.7 | ColumnpduDevMgmtEmdSlave03Alarm1Name | read-write | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.4.1.1.8 | ColumnpduDevMgmtEmdSlave03Alarm2Name | read-write | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.4.1.1.9 | ColumnpduDevMgmtEmdSlave03TempLowWarn | read-write | mandatory | The low warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.4.1.1.10 | ColumnpduDevMgmtEmdSlave03TempLowCrit | read-write | mandatory | The low critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.4.1.1.11 | ColumnpduDevMgmtEmdSlave03TempHighWarn | read-write | mandatory | The high warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.4.1.1.12 | ColumnpduDevMgmtEmdSlave03TempHighCrit | read-write | mandatory | The high critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.4.1.1.13 | ColumnpduDevMgmtEmdSlave03TempCali | read-write | mandatory | The ofset of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.4.1.1.15 | ColumnpduDevMgmtEmdSlave03HumiLowWarn | read-write | mandatory | The low warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.4.1.1.16 | ColumnpduDevMgmtEmdSlave03HumiLowCrit | read-write | mandatory | The low critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.4.1.1.17 | ColumnpduDevMgmtEmdSlave03HumiHighWarn | read-write | mandatory | The high warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.4.1.1.18 | ColumnpduDevMgmtEmdSlave03HumiHighCrit | read-write | mandatory | The high critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.4.1.1.19 | ColumnpduDevMgmtEmdSlave03HumiCali | read-write | mandatory | The ofset of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.4.1.1.21 | ColumnpduDevMgmtEmdSlave03Alarm1Setup | read-write | mandatory | The alarm-1 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.4.1.1.22 | ColumnpduDevMgmtEmdSlave03Alarm2Setup | read-write | mandatory | The alarm-2 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.5 | NodepduDevMgmtEmdSlave04 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.5.1 | TablepduDevMgmtEmdSlave04Table | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.5.1.1 | RowpduDevMgmtEmdSlave04Entry | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.5.1.1.1 | ColumnpduDevMgmtEmdSlave04Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.5.1.1.2 | ColumnpduDevMgmtEmdSlave04Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.5.1.1.3 | ColumnpduDevMgmtEmdSlave04Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.5.1.1.4 | ColumnpduDevMgmtEmdSlave04Name | read-write | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.5.1.1.5 | ColumnpduDevMgmtEmdSlave04TempName | read-write | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.5.1.1.6 | ColumnpduDevMgmtEmdSlave04HumiName | read-write | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.5.1.1.7 | ColumnpduDevMgmtEmdSlave04Alarm1Name | read-write | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.5.1.1.8 | ColumnpduDevMgmtEmdSlave04Alarm2Name | read-write | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.5.1.1.9 | ColumnpduDevMgmtEmdSlave04TempLowWarn | read-write | mandatory | The low warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.5.1.1.10 | ColumnpduDevMgmtEmdSlave04TempLowCrit | read-write | mandatory | The low critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.5.1.1.11 | ColumnpduDevMgmtEmdSlave04TempHighWarn | read-write | mandatory | The high warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.5.1.1.12 | ColumnpduDevMgmtEmdSlave04TempHighCrit | read-write | mandatory | The high critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.5.1.1.13 | ColumnpduDevMgmtEmdSlave04TempCali | read-write | mandatory | The ofset of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.5.1.1.15 | ColumnpduDevMgmtEmdSlave04HumiLowWarn | read-write | mandatory | The low warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.5.1.1.16 | ColumnpduDevMgmtEmdSlave04HumiLowCrit | read-write | mandatory | The low critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.5.1.1.17 | ColumnpduDevMgmtEmdSlave04HumiHighWarn | read-write | mandatory | The high warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.5.1.1.18 | ColumnpduDevMgmtEmdSlave04HumiHighCrit | read-write | mandatory | The high critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.5.1.1.19 | ColumnpduDevMgmtEmdSlave04HumiCali | read-write | mandatory | The ofset of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.5.1.1.21 | ColumnpduDevMgmtEmdSlave04Alarm1Setup | read-write | mandatory | The alarm-1 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.5.1.1.22 | ColumnpduDevMgmtEmdSlave04Alarm2Setup | read-write | mandatory | The alarm-2 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.6 | NodepduDevMgmtEmdSlave05 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.6.1 | TablepduDevMgmtEmdSlave05Table | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.6.1.1 | RowpduDevMgmtEmdSlave05Entry | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.6.1.1.1 | ColumnpduDevMgmtEmdSlave05Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.6.1.1.2 | ColumnpduDevMgmtEmdSlave05Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.6.1.1.3 | ColumnpduDevMgmtEmdSlave05Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.6.1.1.4 | ColumnpduDevMgmtEmdSlave05Name | read-write | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.6.1.1.5 | ColumnpduDevMgmtEmdSlave05TempName | read-write | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.6.1.1.6 | ColumnpduDevMgmtEmdSlave05HumiName | read-write | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.6.1.1.7 | ColumnpduDevMgmtEmdSlave05Alarm1Name | read-write | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.6.1.1.8 | ColumnpduDevMgmtEmdSlave05Alarm2Name | read-write | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.6.1.1.9 | ColumnpduDevMgmtEmdSlave05TempLowWarn | read-write | mandatory | The low warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.6.1.1.10 | ColumnpduDevMgmtEmdSlave05TempLowCrit | read-write | mandatory | The low critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.6.1.1.11 | ColumnpduDevMgmtEmdSlave05TempHighWarn | read-write | mandatory | The high warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.6.1.1.12 | ColumnpduDevMgmtEmdSlave05TempHighCrit | read-write | mandatory | The high critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.6.1.1.13 | ColumnpduDevMgmtEmdSlave05TempCali | read-write | mandatory | The ofset of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.6.1.1.15 | ColumnpduDevMgmtEmdSlave05HumiLowWarn | read-write | mandatory | The low warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.6.1.1.16 | ColumnpduDevMgmtEmdSlave05HumiLowCrit | read-write | mandatory | The low critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.6.1.1.17 | ColumnpduDevMgmtEmdSlave05HumiHighWarn | read-write | mandatory | The high warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.6.1.1.18 | ColumnpduDevMgmtEmdSlave05HumiHighCrit | read-write | mandatory | The high critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.6.1.1.19 | ColumnpduDevMgmtEmdSlave05HumiCali | read-write | mandatory | The ofset of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.6.1.1.21 | ColumnpduDevMgmtEmdSlave05Alarm1Setup | read-write | mandatory | The alarm-1 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.6.1.1.22 | ColumnpduDevMgmtEmdSlave05Alarm2Setup | read-write | mandatory | The alarm-2 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.7 | NodepduDevMgmtEmdSlave06 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.7.1 | TablepduDevMgmtEmdSlave06Table | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.7.1.1 | RowpduDevMgmtEmdSlave06Entry | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.7.1.1.1 | ColumnpduDevMgmtEmdSlave06Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.7.1.1.2 | ColumnpduDevMgmtEmdSlave06Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.7.1.1.3 | ColumnpduDevMgmtEmdSlave06Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.7.1.1.4 | ColumnpduDevMgmtEmdSlave06Name | read-write | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.7.1.1.5 | ColumnpduDevMgmtEmdSlave06TempName | read-write | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.7.1.1.6 | ColumnpduDevMgmtEmdSlave06HumiName | read-write | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.7.1.1.7 | ColumnpduDevMgmtEmdSlave06Alarm1Name | read-write | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.7.1.1.8 | ColumnpduDevMgmtEmdSlave06Alarm2Name | read-write | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.7.1.1.9 | ColumnpduDevMgmtEmdSlave06TempLowWarn | read-write | mandatory | The low warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.7.1.1.10 | ColumnpduDevMgmtEmdSlave06TempLowCrit | read-write | mandatory | The low critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.7.1.1.11 | ColumnpduDevMgmtEmdSlave06TempHighWarn | read-write | mandatory | The high warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.7.1.1.12 | ColumnpduDevMgmtEmdSlave06TempHighCrit | read-write | mandatory | The high critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.7.1.1.13 | ColumnpduDevMgmtEmdSlave06TempCali | read-write | mandatory | The ofset of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.7.1.1.15 | ColumnpduDevMgmtEmdSlave06HumiLowWarn | read-write | mandatory | The low warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.7.1.1.16 | ColumnpduDevMgmtEmdSlave06HumiLowCrit | read-write | mandatory | The low critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.7.1.1.17 | ColumnpduDevMgmtEmdSlave06HumiHighWarn | read-write | mandatory | The high warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.7.1.1.18 | ColumnpduDevMgmtEmdSlave06HumiHighCrit | read-write | mandatory | The high critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.7.1.1.19 | ColumnpduDevMgmtEmdSlave06HumiCali | read-write | mandatory | The ofset of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.7.1.1.21 | ColumnpduDevMgmtEmdSlave06Alarm1Setup | read-write | mandatory | The alarm-1 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.7.1.1.22 | ColumnpduDevMgmtEmdSlave06Alarm2Setup | read-write | mandatory | The alarm-2 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.8 | NodepduDevMgmtEmdSlave07 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.8.1 | TablepduDevMgmtEmdSlave07Table | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.8.1.1 | RowpduDevMgmtEmdSlave07Entry | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.8.1.1.1 | ColumnpduDevMgmtEmdSlave07Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.8.1.1.2 | ColumnpduDevMgmtEmdSlave07Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.8.1.1.3 | ColumnpduDevMgmtEmdSlave07Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.8.1.1.4 | ColumnpduDevMgmtEmdSlave07Name | read-write | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.8.1.1.5 | ColumnpduDevMgmtEmdSlave07TempName | read-write | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.8.1.1.6 | ColumnpduDevMgmtEmdSlave07HumiName | read-write | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.8.1.1.7 | ColumnpduDevMgmtEmdSlave07Alarm1Name | read-write | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.8.1.1.8 | ColumnpduDevMgmtEmdSlave07Alarm2Name | read-write | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.8.1.1.9 | ColumnpduDevMgmtEmdSlave07TempLowWarn | read-write | mandatory | The low warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.8.1.1.10 | ColumnpduDevMgmtEmdSlave07TempLowCrit | read-write | mandatory | The low critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.8.1.1.11 | ColumnpduDevMgmtEmdSlave07TempHighWarn | read-write | mandatory | The high warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.8.1.1.12 | ColumnpduDevMgmtEmdSlave07TempHighCrit | read-write | mandatory | The high critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.8.1.1.13 | ColumnpduDevMgmtEmdSlave07TempCali | read-write | mandatory | The ofset of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.8.1.1.15 | ColumnpduDevMgmtEmdSlave07HumiLowWarn | read-write | mandatory | The low warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.8.1.1.16 | ColumnpduDevMgmtEmdSlave07HumiLowCrit | read-write | mandatory | The low critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.8.1.1.17 | ColumnpduDevMgmtEmdSlave07HumiHighWarn | read-write | mandatory | The high warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.8.1.1.18 | ColumnpduDevMgmtEmdSlave07HumiHighCrit | read-write | mandatory | The high critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.8.1.1.19 | ColumnpduDevMgmtEmdSlave07HumiCali | read-write | mandatory | The ofset of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.8.1.1.21 | ColumnpduDevMgmtEmdSlave07Alarm1Setup | read-write | mandatory | The alarm-1 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.8.1.1.22 | ColumnpduDevMgmtEmdSlave07Alarm2Setup | read-write | mandatory | The alarm-2 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.9 | NodepduDevMgmtEmdSlave08 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.9.1 | TablepduDevMgmtEmdSlave08Table | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.9.1.1 | RowpduDevMgmtEmdSlave08Entry | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.9.1.1.1 | ColumnpduDevMgmtEmdSlave08Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.9.1.1.2 | ColumnpduDevMgmtEmdSlave08Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.9.1.1.3 | ColumnpduDevMgmtEmdSlave08Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.9.1.1.4 | ColumnpduDevMgmtEmdSlave08Name | read-write | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.9.1.1.5 | ColumnpduDevMgmtEmdSlave08TempName | read-write | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.9.1.1.6 | ColumnpduDevMgmtEmdSlave08HumiName | read-write | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.9.1.1.7 | ColumnpduDevMgmtEmdSlave08Alarm1Name | read-write | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.9.1.1.8 | ColumnpduDevMgmtEmdSlave08Alarm2Name | read-write | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.9.1.1.9 | ColumnpduDevMgmtEmdSlave08TempLowWarn | read-write | mandatory | The low warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.9.1.1.10 | ColumnpduDevMgmtEmdSlave08TempLowCrit | read-write | mandatory | The low critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.9.1.1.11 | ColumnpduDevMgmtEmdSlave08TempHighWarn | read-write | mandatory | The high warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.9.1.1.12 | ColumnpduDevMgmtEmdSlave08TempHighCrit | read-write | mandatory | The high critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.9.1.1.13 | ColumnpduDevMgmtEmdSlave08TempCali | read-write | mandatory | The ofset of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.9.1.1.15 | ColumnpduDevMgmtEmdSlave08HumiLowWarn | read-write | mandatory | The low warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.9.1.1.16 | ColumnpduDevMgmtEmdSlave08HumiLowCrit | read-write | mandatory | The low critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.9.1.1.17 | ColumnpduDevMgmtEmdSlave08HumiHighWarn | read-write | mandatory | The high warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.9.1.1.18 | ColumnpduDevMgmtEmdSlave08HumiHighCrit | read-write | mandatory | The high critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.9.1.1.19 | ColumnpduDevMgmtEmdSlave08HumiCali | read-write | mandatory | The ofset of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.9.1.1.21 | ColumnpduDevMgmtEmdSlave08Alarm1Setup | read-write | mandatory | The alarm-1 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.9.1.1.22 | ColumnpduDevMgmtEmdSlave08Alarm2Setup | read-write | mandatory | The alarm-2 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.10 | NodepduDevMgmtEmdSlave09 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.10.1 | TablepduDevMgmtEmdSlave09Table | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.10.1.1 | RowpduDevMgmtEmdSlave09Entry | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.10.1.1.1 | ColumnpduDevMgmtEmdSlave09Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.10.1.1.2 | ColumnpduDevMgmtEmdSlave09Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.10.1.1.3 | ColumnpduDevMgmtEmdSlave09Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.10.1.1.4 | ColumnpduDevMgmtEmdSlave09Name | read-write | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.10.1.1.5 | ColumnpduDevMgmtEmdSlave09TempName | read-write | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.10.1.1.6 | ColumnpduDevMgmtEmdSlave09HumiName | read-write | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.10.1.1.7 | ColumnpduDevMgmtEmdSlave09Alarm1Name | read-write | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.10.1.1.8 | ColumnpduDevMgmtEmdSlave09Alarm2Name | read-write | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.10.1.1.9 | ColumnpduDevMgmtEmdSlave09TempLowWarn | read-write | mandatory | The low warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.10.1.1.10 | ColumnpduDevMgmtEmdSlave09TempLowCrit | read-write | mandatory | The low critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.10.1.1.11 | ColumnpduDevMgmtEmdSlave09TempHighWarn | read-write | mandatory | The high warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.10.1.1.12 | ColumnpduDevMgmtEmdSlave09TempHighCrit | read-write | mandatory | The high critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.10.1.1.13 | ColumnpduDevMgmtEmdSlave09TempCali | read-write | mandatory | The ofset of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.10.1.1.15 | ColumnpduDevMgmtEmdSlave09HumiLowWarn | read-write | mandatory | The low warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.10.1.1.16 | ColumnpduDevMgmtEmdSlave09HumiLowCrit | read-write | mandatory | The low critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.10.1.1.17 | ColumnpduDevMgmtEmdSlave09HumiHighWarn | read-write | mandatory | The high warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.10.1.1.18 | ColumnpduDevMgmtEmdSlave09HumiHighCrit | read-write | mandatory | The high critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.10.1.1.19 | ColumnpduDevMgmtEmdSlave09HumiCali | read-write | mandatory | The ofset of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.10.1.1.21 | ColumnpduDevMgmtEmdSlave09Alarm1Setup | read-write | mandatory | The alarm-1 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.10.1.1.22 | ColumnpduDevMgmtEmdSlave09Alarm2Setup | read-write | mandatory | The alarm-2 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.11 | NodepduDevMgmtEmdSlave10 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.11.1 | TablepduDevMgmtEmdSlave10Table | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.11.1.1 | RowpduDevMgmtEmdSlave10Entry | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.11.1.1.1 | ColumnpduDevMgmtEmdSlave10Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.11.1.1.2 | ColumnpduDevMgmtEmdSlave10Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.11.1.1.3 | ColumnpduDevMgmtEmdSlave10Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.11.1.1.4 | ColumnpduDevMgmtEmdSlave10Name | read-write | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.11.1.1.5 | ColumnpduDevMgmtEmdSlave10TempName | read-write | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.11.1.1.6 | ColumnpduDevMgmtEmdSlave10HumiName | read-write | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.11.1.1.7 | ColumnpduDevMgmtEmdSlave10Alarm1Name | read-write | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.11.1.1.8 | ColumnpduDevMgmtEmdSlave10Alarm2Name | read-write | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.11.1.1.9 | ColumnpduDevMgmtEmdSlave10TempLowWarn | read-write | mandatory | The low warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.11.1.1.10 | ColumnpduDevMgmtEmdSlave10TempLowCrit | read-write | mandatory | The low critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.11.1.1.11 | ColumnpduDevMgmtEmdSlave10TempHighWarn | read-write | mandatory | The high warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.11.1.1.12 | ColumnpduDevMgmtEmdSlave10TempHighCrit | read-write | mandatory | The high critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.11.1.1.13 | ColumnpduDevMgmtEmdSlave10TempCali | read-write | mandatory | The ofset of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.11.1.1.15 | ColumnpduDevMgmtEmdSlave10HumiLowWarn | read-write | mandatory | The low warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.11.1.1.16 | ColumnpduDevMgmtEmdSlave10HumiLowCrit | read-write | mandatory | The low critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.11.1.1.17 | ColumnpduDevMgmtEmdSlave10HumiHighWarn | read-write | mandatory | The high warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.11.1.1.18 | ColumnpduDevMgmtEmdSlave10HumiHighCrit | read-write | mandatory | The high critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.11.1.1.19 | ColumnpduDevMgmtEmdSlave10HumiCali | read-write | mandatory | The ofset of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.11.1.1.21 | ColumnpduDevMgmtEmdSlave10Alarm1Setup | read-write | mandatory | The alarm-1 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.11.1.1.22 | ColumnpduDevMgmtEmdSlave10Alarm2Setup | read-write | mandatory | The alarm-2 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.12 | NodepduDevMgmtEmdSlave11 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.12.1 | TablepduDevMgmtEmdSlave11Table | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.12.1.1 | RowpduDevMgmtEmdSlave11Entry | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.12.1.1.1 | ColumnpduDevMgmtEmdSlave11Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.12.1.1.2 | ColumnpduDevMgmtEmdSlave11Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.12.1.1.3 | ColumnpduDevMgmtEmdSlave11Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.12.1.1.4 | ColumnpduDevMgmtEmdSlave11Name | read-write | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.12.1.1.5 | ColumnpduDevMgmtEmdSlave11TempName | read-write | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.12.1.1.6 | ColumnpduDevMgmtEmdSlave11HumiName | read-write | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.12.1.1.7 | ColumnpduDevMgmtEmdSlave11Alarm1Name | read-write | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.12.1.1.8 | ColumnpduDevMgmtEmdSlave11Alarm2Name | read-write | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.12.1.1.9 | ColumnpduDevMgmtEmdSlave11TempLowWarn | read-write | mandatory | The low warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.12.1.1.10 | ColumnpduDevMgmtEmdSlave11TempLowCrit | read-write | mandatory | The low critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.12.1.1.11 | ColumnpduDevMgmtEmdSlave11TempHighWarn | read-write | mandatory | The high warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.12.1.1.12 | ColumnpduDevMgmtEmdSlave11TempHighCrit | read-write | mandatory | The high critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.12.1.1.13 | ColumnpduDevMgmtEmdSlave11TempCali | read-write | mandatory | The ofset of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.12.1.1.15 | ColumnpduDevMgmtEmdSlave11HumiLowWarn | read-write | mandatory | The low warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.12.1.1.16 | ColumnpduDevMgmtEmdSlave11HumiLowCrit | read-write | mandatory | The low critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.12.1.1.17 | ColumnpduDevMgmtEmdSlave11HumiHighWarn | read-write | mandatory | The high warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.12.1.1.18 | ColumnpduDevMgmtEmdSlave11HumiHighCrit | read-write | mandatory | The high critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.12.1.1.19 | ColumnpduDevMgmtEmdSlave11HumiCali | read-write | mandatory | The ofset of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.12.1.1.21 | ColumnpduDevMgmtEmdSlave11Alarm1Setup | read-write | mandatory | The alarm-1 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.12.1.1.22 | ColumnpduDevMgmtEmdSlave11Alarm2Setup | read-write | mandatory | The alarm-2 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.13 | NodepduDevMgmtEmdSlave12 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.13.1 | TablepduDevMgmtEmdSlave12Table | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.13.1.1 | RowpduDevMgmtEmdSlave12Entry | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.13.1.1.1 | ColumnpduDevMgmtEmdSlave12Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.13.1.1.2 | ColumnpduDevMgmtEmdSlave12Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.13.1.1.3 | ColumnpduDevMgmtEmdSlave12Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.13.1.1.4 | ColumnpduDevMgmtEmdSlave12Name | read-write | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.13.1.1.5 | ColumnpduDevMgmtEmdSlave12TempName | read-write | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.13.1.1.6 | ColumnpduDevMgmtEmdSlave12HumiName | read-write | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.13.1.1.7 | ColumnpduDevMgmtEmdSlave12Alarm1Name | read-write | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.13.1.1.8 | ColumnpduDevMgmtEmdSlave12Alarm2Name | read-write | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.13.1.1.9 | ColumnpduDevMgmtEmdSlave12TempLowWarn | read-write | mandatory | The low warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.13.1.1.10 | ColumnpduDevMgmtEmdSlave12TempLowCrit | read-write | mandatory | The low critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.13.1.1.11 | ColumnpduDevMgmtEmdSlave12TempHighWarn | read-write | mandatory | The high warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.13.1.1.12 | ColumnpduDevMgmtEmdSlave12TempHighCrit | read-write | mandatory | The high critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.13.1.1.13 | ColumnpduDevMgmtEmdSlave12TempCali | read-write | mandatory | The ofset of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.13.1.1.15 | ColumnpduDevMgmtEmdSlave12HumiLowWarn | read-write | mandatory | The low warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.13.1.1.16 | ColumnpduDevMgmtEmdSlave12HumiLowCrit | read-write | mandatory | The low critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.13.1.1.17 | ColumnpduDevMgmtEmdSlave12HumiHighWarn | read-write | mandatory | The high warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.13.1.1.18 | ColumnpduDevMgmtEmdSlave12HumiHighCrit | read-write | mandatory | The high critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.13.1.1.19 | ColumnpduDevMgmtEmdSlave12HumiCali | read-write | mandatory | The ofset of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.13.1.1.21 | ColumnpduDevMgmtEmdSlave12Alarm1Setup | read-write | mandatory | The alarm-1 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.13.1.1.22 | ColumnpduDevMgmtEmdSlave12Alarm2Setup | read-write | mandatory | The alarm-2 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.14 | NodepduDevMgmtEmdSlave13 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.14.1 | TablepduDevMgmtEmdSlave13Table | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.14.1.1 | RowpduDevMgmtEmdSlave13Entry | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.14.1.1.1 | ColumnpduDevMgmtEmdSlave13Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.14.1.1.2 | ColumnpduDevMgmtEmdSlave13Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.14.1.1.3 | ColumnpduDevMgmtEmdSlave13Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.14.1.1.4 | ColumnpduDevMgmtEmdSlave13Name | read-write | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.14.1.1.5 | ColumnpduDevMgmtEmdSlave13TempName | read-write | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.14.1.1.6 | ColumnpduDevMgmtEmdSlave13HumiName | read-write | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.14.1.1.7 | ColumnpduDevMgmtEmdSlave13Alarm1Name | read-write | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.14.1.1.8 | ColumnpduDevMgmtEmdSlave13Alarm2Name | read-write | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.14.1.1.9 | ColumnpduDevMgmtEmdSlave13TempLowWarn | read-write | mandatory | The low warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.14.1.1.10 | ColumnpduDevMgmtEmdSlave13TempLowCrit | read-write | mandatory | The low critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.14.1.1.11 | ColumnpduDevMgmtEmdSlave13TempHighWarn | read-write | mandatory | The high warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.14.1.1.12 | ColumnpduDevMgmtEmdSlave13TempHighCrit | read-write | mandatory | The high critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.14.1.1.13 | ColumnpduDevMgmtEmdSlave13TempCali | read-write | mandatory | The ofset of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.14.1.1.15 | ColumnpduDevMgmtEmdSlave13HumiLowWarn | read-write | mandatory | The low warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.14.1.1.16 | ColumnpduDevMgmtEmdSlave13HumiLowCrit | read-write | mandatory | The low critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.14.1.1.17 | ColumnpduDevMgmtEmdSlave13HumiHighWarn | read-write | mandatory | The high warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.14.1.1.18 | ColumnpduDevMgmtEmdSlave13HumiHighCrit | read-write | mandatory | The high critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.14.1.1.19 | ColumnpduDevMgmtEmdSlave13HumiCali | read-write | mandatory | The ofset of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.14.1.1.21 | ColumnpduDevMgmtEmdSlave13Alarm1Setup | read-write | mandatory | The alarm-1 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.14.1.1.22 | ColumnpduDevMgmtEmdSlave13Alarm2Setup | read-write | mandatory | The alarm-2 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.15 | NodepduDevMgmtEmdSlave14 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.15.1 | TablepduDevMgmtEmdSlave14Table | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.15.1.1 | RowpduDevMgmtEmdSlave14Entry | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.15.1.1.1 | ColumnpduDevMgmtEmdSlave14Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.15.1.1.2 | ColumnpduDevMgmtEmdSlave14Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.15.1.1.3 | ColumnpduDevMgmtEmdSlave14Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.15.1.1.4 | ColumnpduDevMgmtEmdSlave14Name | read-write | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.15.1.1.5 | ColumnpduDevMgmtEmdSlave14TempName | read-write | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.15.1.1.6 | ColumnpduDevMgmtEmdSlave14HumiName | read-write | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.15.1.1.7 | ColumnpduDevMgmtEmdSlave14Alarm1Name | read-write | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.15.1.1.8 | ColumnpduDevMgmtEmdSlave14Alarm2Name | read-write | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.15.1.1.9 | ColumnpduDevMgmtEmdSlave14TempLowWarn | read-write | mandatory | The low warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.15.1.1.10 | ColumnpduDevMgmtEmdSlave14TempLowCrit | read-write | mandatory | The low critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.15.1.1.11 | ColumnpduDevMgmtEmdSlave14TempHighWarn | read-write | mandatory | The high warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.15.1.1.12 | ColumnpduDevMgmtEmdSlave14TempHighCrit | read-write | mandatory | The high critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.15.1.1.13 | ColumnpduDevMgmtEmdSlave14TempCali | read-write | mandatory | The ofset of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.15.1.1.15 | ColumnpduDevMgmtEmdSlave14HumiLowWarn | read-write | mandatory | The low warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.15.1.1.16 | ColumnpduDevMgmtEmdSlave14HumiLowCrit | read-write | mandatory | The low critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.15.1.1.17 | ColumnpduDevMgmtEmdSlave14HumiHighWarn | read-write | mandatory | The high warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.15.1.1.18 | ColumnpduDevMgmtEmdSlave14HumiHighCrit | read-write | mandatory | The high critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.15.1.1.19 | ColumnpduDevMgmtEmdSlave14HumiCali | read-write | mandatory | The ofset of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.15.1.1.21 | ColumnpduDevMgmtEmdSlave14Alarm1Setup | read-write | mandatory | The alarm-1 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.15.1.1.22 | ColumnpduDevMgmtEmdSlave14Alarm2Setup | read-write | mandatory | The alarm-2 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.16 | NodepduDevMgmtEmdSlave15 | |||
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.16.1 | TablepduDevMgmtEmdSlave15Table | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.16.1.1 | RowpduDevMgmtEmdSlave15Entry | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.16.1.1.1 | ColumnpduDevMgmtEmdSlave15Index | read-only | mandatory | The index to a emd entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.16.1.1.2 | ColumnpduDevMgmtEmdSlave15Valid | read-only | mandatory | The online status of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.16.1.1.3 | ColumnpduDevMgmtEmdSlave15Type | read-only | mandatory | The type of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.16.1.1.4 | ColumnpduDevMgmtEmdSlave15Name | read-write | mandatory | The name of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.16.1.1.5 | ColumnpduDevMgmtEmdSlave15TempName | read-write | mandatory | The name of emd temperature. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.16.1.1.6 | ColumnpduDevMgmtEmdSlave15HumiName | read-write | mandatory | The name of emd humidity. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.16.1.1.7 | ColumnpduDevMgmtEmdSlave15Alarm1Name | read-write | mandatory | The name of emd alarm-1. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.16.1.1.8 | ColumnpduDevMgmtEmdSlave15Alarm2Name | read-write | mandatory | The name of emd alarm-2. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.16.1.1.9 | ColumnpduDevMgmtEmdSlave15TempLowWarn | read-write | mandatory | The low warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.16.1.1.10 | ColumnpduDevMgmtEmdSlave15TempLowCrit | read-write | mandatory | The low critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.16.1.1.11 | ColumnpduDevMgmtEmdSlave15TempHighWarn | read-write | mandatory | The high warning threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.16.1.1.12 | ColumnpduDevMgmtEmdSlave15TempHighCrit | read-write | mandatory | The high critical threshold of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.16.1.1.13 | ColumnpduDevMgmtEmdSlave15TempCali | read-write | mandatory | The ofset of temperature of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.16.1.1.15 | ColumnpduDevMgmtEmdSlave15HumiLowWarn | read-write | mandatory | The low warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.16.1.1.16 | ColumnpduDevMgmtEmdSlave15HumiLowCrit | read-write | mandatory | The low critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.16.1.1.17 | ColumnpduDevMgmtEmdSlave15HumiHighWarn | read-write | mandatory | The high warning threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.16.1.1.18 | ColumnpduDevMgmtEmdSlave15HumiHighCrit | read-write | mandatory | The high critical threshold of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.16.1.1.19 | ColumnpduDevMgmtEmdSlave15HumiCali | read-write | mandatory | The ofset of humidity of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.16.1.1.21 | ColumnpduDevMgmtEmdSlave15Alarm1Setup | read-write | mandatory | The alarm-1 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.3.3.16.1.1.22 | ColumnpduDevMgmtEmdSlave15Alarm2Setup | read-write | mandatory | The alarm-2 setup of emd. |
| 1.3.6.1.4.1.42610.1.4.1.1.4 | NodepduNetwork | |||
| 1.3.6.1.4.1.42610.1.4.1.1.4.1 | NodepduNetworkTcp | |||
| 1.3.6.1.4.1.42610.1.4.1.1.4.1.1 | ScalarpduNetworkTcpIpv4DhcpEn | read-write | mandatory | Enable/disable DHCP protocol. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.1.2 | ScalarpduNetworkTcpIpv4Address | read-write | mandatory | The ip address that NMS can identify the managed device. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.1.3 | ScalarpduNetworkTcpIpv4Gateway | read-write | mandatory | The default gateway that allow device managed through routers. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.1.4 | ScalarpduNetworkTcpIpv4Mask | read-write | mandatory | Internet address subnet mask. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.1.5 | ScalarpduNetworkTcpIpv4Dns1 | read-write | mandatory | Internet address of Primary DNS Server. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.1.6 | ScalarpduNetworkTcpIpv4Dns2 | read-write | mandatory | Internet address of Secondary DNS. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.1.7 | ScalarpduNetworkTcpIpv6En | read-write | mandatory | Enable/disable IPv6 protocol. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.1.8 | ScalarpduNetworkTcpIpv6AutoConfig | read-write | mandatory | IPv6 Auto-config or Maual setting. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.1.9 | ScalarpduNetworkTcpIpv6Address | read-write | mandatory | The ipv6 address that NMS can identify the managed device. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.1.10 | ScalarpduNetworkTcpIpv6Prefix | read-write | mandatory | The prefix length for ipv6 address. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.1.11 | ScalarpduNetworkTcpIpv6Router | read-write | mandatory | The default gateway that allow device managed through routers. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.1.12 | ScalarpduNetworkTcpIpv6PrimaryDNS | read-write | mandatory | Internet address of Primary DNS Server |
| 1.3.6.1.4.1.42610.1.4.1.1.4.1.13 | ScalarpduNetworkTcpIpv6SecondaryDNS | read-write | mandatory | Internet address of Secondary DNS |
| 1.3.6.1.4.1.42610.1.4.1.1.4.2 | NodepduNetworkDualEth | |||
| 1.3.6.1.4.1.42610.1.4.1.1.4.2.1 | ScalarpduNetworkDualEthMode | read-write | mandatory | Dual ethernet mode. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.2.2 | ScalarpduNetworkDualEthDownDelay | read-write | mandatory | The down delay of ethernet mode. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.2.3 | ScalarpduNetworkDualEthUpDelay | read-write | mandatory | The down delay of ethernet mode. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.2.4 | ScalarpduNetworkDualEthMiimon | read-write | mandatory | The MII monitoring of ethernet mode. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.2.5 | ScalarpduNetworkDualEthPrimary | read-write | mandatory | The primary ethernet port, Only valid active-backup. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.3 | NodepduNetworkAccessIp | |||
| 1.3.6.1.4.1.42610.1.4.1.1.4.3.1 | ScalarpduNetworkAccessIpEn | read-write | mandatory | Enable/disable access ip table. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.3.2 | TablepduNetworkAccessIpTable | not-accessible | mandatory | Display a list of access ip table of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.3.2.1 | RowpduNetworkAccessIpTblEntry | not-accessible | mandatory | Display a list of access ip tablen of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.3.2.1.1 | ColumnpduNetworkAccessIpTblIndex | read-only | mandatory | The index to a access ip entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.3.2.1.2 | ColumnpduNetworkAccessIpTblAddr | read-write | mandatory | The ip address of access ip. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.3.2.1.3 | ColumnpduNetworkAccessIpTblPrefix | read-write | mandatory | The prefix length of access ip. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.3.2.1.4 | ColumnpduNetworkAccessIpTblAction | read-write | mandatory | The action of access ip. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.4 | NodepduNetworkSecurity | |||
| 1.3.6.1.4.1.42610.1.4.1.1.4.4.1 | ScalarpduNetworkSecurityAccessProtectEn | read-write | mandatory | Enable/disable access protect function. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.4.2 | ScalarpduNetworkSecuritySshEn | read-write | mandatory | Enable/disable protect SSH function. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.4.3 | ScalarpduNetworkSecuritySshInterval | read-write | mandatory | The interval of protect SSH. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.4.4 | ScalarpduNetworkSecuritySshTime | read-write | mandatory | The time of protect SSH. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.4.5 | ScalarpduNetworkSecuritySshBlock | read-write | mandatory | The block time of protect SSH. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.4.6 | ScalarpduNetworkSecuritySnmpEn | read-write | mandatory | Enable/disable protect SNMP function. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.4.7 | ScalarpduNetworkSecuritySnmpInterval | read-write | mandatory | The interval of protect SNMP. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.4.8 | ScalarpduNetworkSecuritySnmpTime | read-write | mandatory | The time of protect SNMP. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.4.9 | ScalarpduNetworkSecuritySnmpBlock | read-write | mandatory | The block time of protect SNMP. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.4.10 | ScalarpduNetworkSecurityHttpEn | read-write | mandatory | Enable/disable protect HTTP(s) function. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.4.11 | ScalarpduNetworkSecurityHttpInterval | read-write | mandatory | The interval of protect HTTP(s). |
| 1.3.6.1.4.1.42610.1.4.1.1.4.4.12 | ScalarpduNetworkSecurityHttpTime | read-write | mandatory | The time of protect HTTP(s). |
| 1.3.6.1.4.1.42610.1.4.1.1.4.4.13 | ScalarpduNetworkSecurityHttpBlock | read-write | mandatory | The block time of protect HTTP(s). |
| 1.3.6.1.4.1.42610.1.4.1.1.4.5 | NodepduNetworkService | |||
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.1 | NodepduNetworkServiceSsh | |||
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.1.1 | ScalarpduNetworkServiceSshEn | read-write | mandatory | Enable/disable SSH Server Service. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.1.2 | ScalarpduNetworkServiceSshPort | read-write | mandatory | The Port Number of SSH Server Service. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.2 | NodepduNetworkServiceHttps | |||
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.2.1 | ScalarpduNetworkServiceHttpsEn | read-write | mandatory | Enable/disable HTTPs Server Service. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.2.2 | ScalarpduNetworkServiceHttpsPort | read-write | mandatory | The Port Number of HTTPs Server Service. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.2.3 | ScalarpduNetworkServiceHttpsForce | read-write | mandatory | Force use HTTPs Server Service only. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.3 | NodepduNetworkServicePing | |||
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.3.1 | ScalarpduNetworkServicePingEn | read-write | mandatory | Enable/disable to response to PING request. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.4 | NodepduNetworkServiceModbus | |||
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.4.1 | ScalarpduNetworkServiceModbusEn | read-write | mandatory | Enable/disable Modbus Server Service. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.4.2 | ScalarpduNetworkServiceModbusPort | read-write | mandatory | The Port Number of Modbus Server Service. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.5 | NodepduNetworkServiceRadius | |||
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.5.1 | ScalarpduNetworkServiceRadiusEn | read-write | mandatory | Enable/disable RADIUS Client Service. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.5.2 | ScalarpduNetworkServiceRadiusIp | read-write | mandatory | The IP Address of RADIUS Client Service. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.5.3 | ScalarpduNetworkServiceRadiusPort | read-write | mandatory | The Port Number of RADIUS Client Service. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.5.4 | ScalarpduNetworkServiceRadiusSecKey | read-write | mandatory | The Secret Key of RADIUS Client Service. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.5.5 | ScalarpduNetworkServiceRadiusTimeout | read-write | mandatory | The Timeout Interval of RADIUS Client Service in seconds. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.5.6 | ScalarpduNetworkServiceRadiusRetry | read-write | mandatory | The Retry Times of RADIUS Client Service. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.6 | NodepduNetworkServiceLdap | |||
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.6.1 | ScalarpduNetworkServiceLdapEn | read-write | mandatory | Enable/disable LDAP Client Service. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.6.2 | ScalarpduNetworkServiceLdapIp | read-write | mandatory | The IP Address of LDAP Client Service. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.6.3 | ScalarpduNetworkServiceLdapPort | read-write | mandatory | The Port Number of LDAP Client Service. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.6.4 | ScalarpduNetworkServiceLdapTls | read-write | mandatory | Enable/disable LDAP TLS connection. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.6.5 | ScalarpduNetworkServiceLdapBaseDn | read-write | mandatory | The Base DN of LDAP Client Service. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.7 | NodepduNetworkServiceTacacs | |||
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.7.1 | ScalarpduNetworkServiceTacacsEn | read-write | mandatory | Enable/disable TACACS+ Client Service. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.7.2 | ScalarpduNetworkServiceTacacsIp | read-write | mandatory | The IP Address of TACACS+ Client Service. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.7.3 | ScalarpduNetworkServiceTacacsPort | read-write | mandatory | The Port Number of TACACS+ Client Service. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.7.4 | ScalarpduNetworkServiceTacacsSecKey | read-write | mandatory | The Secret Key of TACACS+ Client Service. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.7.5 | ScalarpduNetworkServiceTacacsTimeout | read-write | mandatory | The Timeout Interval of TACACS+ Client Service in seconds. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.7.6 | ScalarpduNetworkServiceTacacsRetry | read-write | mandatory | The Retry Times of TACACS+ Client Service. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.5.7.7 | ScalarpduNetworkServiceTacacsAuthMode | read-write | mandatory | The Authentication Mode of TACACS+ Client Service. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.6 | NodepduNetworkSnmpSetting | |||
| 1.3.6.1.4.1.42610.1.4.1.1.4.6.1 | ScalarpduNetworkSnmpSettingEn | read-write | mandatory | Enable/disable SNMP Server Service. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.6.2 | ScalarpduNetworkSnmpSettingPort | read-write | mandatory | The Port Number of SNMP Server Service. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.7 | NodepduNetworkSnmpTrap | |||
| 1.3.6.1.4.1.42610.1.4.1.1.4.7.1 | TablepduNetworkSnmpTrapTable | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.7.1.1 | RowpduNetworkSnmpTrapEntry | not-accessible | mandatory | Display a list of the emd information of master. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.7.1.1.1 | ColumnpduNetworkSnmpTrapIndex | read-only | mandatory | The index to a trap receiver entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.7.1.1.2 | ColumnpduNetworkSnmpTrapIp | read-write | mandatory | The IP address of the manager to send a trap to. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.7.1.1.3 | ColumnpduNetworkSnmpTrapEvtLev | read-write | mandatory | The severity level of traps to be received by this manager. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.7.1.1.4 | ColumnpduNetworkSnmpTrapVer | read-write | mandatory | The SNMP Trap version of trap receivers. |
| 1.3.6.1.4.1.42610.1.4.1.1.4.7.1.1.5 | ColumnpduNetworkSnmpTrapDesc | read-write | mandatory | Description of trap receivers. |
| 1.3.6.1.4.1.42610.1.4.1.1.5 | NodepduSetting | |||
| 1.3.6.1.4.1.42610.1.4.1.1.5.1 | NodepduSettingSys | |||
| 1.3.6.1.4.1.42610.1.4.1.1.5.1.1 | ScalarpduSettingSysName | read-write | mandatory | The name of system. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.1.2 | ScalarpduSettingSysContact | read-write | mandatory | The contact of system. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.1.3 | ScalarpduSettingSysLocation | read-write | mandatory | The location of system. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.1.4 | ScalarpduSettingLogInterval | read-write | mandatory | The Log Interval of system. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.1.5 | ScalarpduSettingWebRefresh | read-write | mandatory | The Web Refresh Interval of system. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.2 | NodepduSettingTime | |||
| 1.3.6.1.4.1.42610.1.4.1.1.5.2.1 | ScalarpduSettingNowTime | read-only | mandatory | The date/time in agent |
| 1.3.6.1.4.1.42610.1.4.1.1.5.2.2 | ScalarpduSettingTimeZone | read-write | mandatory | Time Zone to use when synchronize with NTP server. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.2.3 | ScalarpduSettingTimeFormat | read-write | mandatory | Date Format |
| 1.3.6.1.4.1.42610.1.4.1.1.5.2.5 | ScalarpduSettingTimeManualDate | read-write | mandatory | The date in agent, format is (dd/mm/yyyy) |
| 1.3.6.1.4.1.42610.1.4.1.1.5.2.6 | ScalarpduSettingTimeManualTime | read-write | mandatory | The time in agent, format is (hh:mm:ss) |
| 1.3.6.1.4.1.42610.1.4.1.1.5.2.7 | ScalarpduSettingTimeDayLightSaving | read-write | mandatory | Enable/disable the Day Light Saving when synchronize with NTP server. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.3 | NodepduSettingNtp | |||
| 1.3.6.1.4.1.42610.1.4.1.1.5.3.1 | ScalarpduSettingNtpEn | read-write | mandatory | Enable or disable the agent to synchronize date/time with NTP server. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.3.2 | ScalarpduSettingNtpServer | read-write | mandatory | The ip address of NTP server. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.3.3 | ScalarpduSettingNtpSyncInterval | read-write | mandatory | The Sync Interval with NTP server. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.3.4 | ScalarpduSettingNtpSyncUnit | read-write | mandatory | The Unit of Sync Interval |
| 1.3.6.1.4.1.42610.1.4.1.1.5.4 | NodepduSettingAuth | |||
| 1.3.6.1.4.1.42610.1.4.1.1.5.4.1 | ScalarpduSettingAuthAdminName | read-write | mandatory | The admin name of system. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.4.2 | ScalarpduSettingAuthAdminPasswd | read-write | mandatory | The admin password of system. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.5 | NodepduSettingiEC | |||
| 1.3.6.1.4.1.42610.1.4.1.1.5.5.1 | ScalarpduSettingiECEn | read-write | mandatory | Enable/disable iEC function. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.5.2 | ScalarpduSettingiECServer | read-write | mandatory | The ip address of iEC server. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.5.3 | ScalarpduSettingiECPort | read-write | mandatory | The port number of iEC server. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.5.4 | ScalarpduSettingiECPasswd | read-write | mandatory | The password of iEC server. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.6 | NodepduSettingMaint | |||
| 1.3.6.1.4.1.42610.1.4.1.1.5.6.1 | ScalarpduSettingMaintResetToDefault | read-write | mandatory | Reset the parameter of PDU to default. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.7 | NodepduSettingSmtp | |||
| 1.3.6.1.4.1.42610.1.4.1.1.5.7.1 | ScalarpduSettingSmtpIp | read-write | mandatory | The address of Email server. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.7.2 | ScalarpduSettingSmtpPort | read-write | mandatory | The UDP port for Email Server. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.7.3 | ScalarpduSettingSmtpSender | read-write | mandatory | The sender's Email address. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.7.4 | ScalarpduSettingSmtpSubject | read-write | mandatory | The prefix string of mail subject |
| 1.3.6.1.4.1.42610.1.4.1.1.5.7.5 | ScalarpduSettingSmtpAuthEn | read-write | mandatory | Enable/disable SMTP Authentication. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.7.6 | ScalarpduSettingSmtpAuthUser | read-write | mandatory | The user name of SMTP Authentication. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.7.7 | ScalarpduSettingSmtpAuthPasswd | read-write | mandatory | The password of SMTP Authentication. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.8 | NodepduSettingMailNotify | |||
| 1.3.6.1.4.1.42610.1.4.1.1.5.8.1 | TablepduSettingMailNotifyTable | not-accessible | mandatory | A list of managers to send email notification to. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.8.1.1 | RowpduSettingMailNotifyEntry | not-accessible | mandatory | The managers to send email notification to. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.8.1.1.1 | ColumnpduSettingMailNotifyIndex | read-only | mandatory | The index to a email notification receiver entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.8.1.1.2 | ColumnpduSettingMailNotifyRecvAddr | read-write | mandatory | The Email address of the manager to send a email notification to. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.8.1.1.3 | ColumnpduSettingMailNotifyType | read-write | mandatory | The Email Type of email notification receivers. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.8.1.1.4 | ColumnpduSettingMailNotifyEvtLev | read-write | mandatory | The severity level of email notification to be received by this manager. |
| 1.3.6.1.4.1.42610.1.4.1.1.5.8.1.1.5 | ColumnpduSettingMailNotifyDesc | read-write | mandatory | Description of email notification receivers. |
| 1.3.6.1.4.1.42610.1.4.1.1.6 | NodepduLog | |||
| 1.3.6.1.4.1.42610.1.4.1.1.6.1 | ScalarpduLogSyslogEvtEn | read-write | mandatory | Enable/disable the transmission event log of the syslog server. |
| 1.3.6.1.4.1.42610.1.4.1.1.6.2 | ScalarpduLogSyslogEvtIp | read-write | mandatory | The address of event log of syslog server. |
| 1.3.6.1.4.1.42610.1.4.1.1.6.3 | ScalarpduLogSyslogEvtPort | read-write | mandatory | The port number of event log of syslog Server. |
| 1.3.6.1.4.1.42610.1.4.1.1.6.4 | ScalarpduLogSyslogHisEn | read-write | mandatory | Enable/disable the transmission history log of the syslog server. |
| 1.3.6.1.4.1.42610.1.4.1.1.6.5 | ScalarpduLogSyslogHisIp | read-write | mandatory | The address of history log of syslog server. |
| 1.3.6.1.4.1.42610.1.4.1.1.6.6 | ScalarpduLogSyslogHisPort | read-write | mandatory | The port number of history log of syslog Server. |
| 1.3.6.1.4.1.42610.1.4.1.1.7 | NodepduAdvanced | |||
| 1.3.6.1.4.1.42610.1.4.1.1.7.1 | NodepduAdvWifi | |||
| 1.3.6.1.4.1.42610.1.4.1.1.7.1.1 | ScalarpduAdvWifiCtrl | read-write | mandatory | Enable/disable the Wifi function. |
| 1.3.6.1.4.1.42610.1.4.1.1.7.1.2 | ScalarpduAdvWifiSsid | read-write | mandatory | The ssid name of wifi, using base64(aes-cbc-256) encryption. |
| 1.3.6.1.4.1.42610.1.4.1.1.7.1.3 | ScalarpduAdvWifiPasswd | read-write | mandatory | The password of wifi. |
| 1.3.6.1.4.1.42610.1.4.1.1.7.1.4 | ScalarpduAdvWifiEncryption | read-write | mandatory | The encryption of wifi. |
| 1.3.6.1.4.1.42610.1.4.1.1.7.1.5 | ScalarpduAdvWifiSecurity | read-write | mandatory | The security of wifi. |
| 1.3.6.1.4.1.42610.1.4.1.1.7.1.6 | ScalarpduAdvWifiSet | read-write | mandatory | Set the config to Wifi. |
| 1.3.6.1.4.1.42610.1.4.1.1.7.1.7 | ScalarpduAdvWifiConnSt | read-only | mandatory | The connect status of wifi. |
| 1.3.6.1.4.1.42610.1.4.1.1.7.1.8 | ScalarpduAdvWifiIpAddr | read-only | mandatory | The ip address of wifi. |
| 1.3.6.1.4.1.42610.1.4.1.1.7.1.9 | ScalarpduAdvWifiNetMask | read-only | mandatory | The network mask of wifi. |
| 1.3.6.1.4.1.42610.1.4.1.1.7.1.10 | ScalarpduAdvWifiGwAddr | read-only | mandatory | The ssid name of wifi. |
| 1.3.6.1.4.1.42610.1.4.1.1.7.1.11 | ScalarpduAdvWifiMacAddr | read-only | mandatory | The mac address of wifi. |
| 1.3.6.1.4.1.42610.1.4.1.1.7.1.12 | ScalarpduAdvWifiReconnect | read-write | mandatory | Reconnect wifi. |
| 1.3.6.1.4.1.42610.1.4.1.1.7.2 | NodepduAdvWiSms | |||
| 1.3.6.1.4.1.42610.1.4.1.1.7.2.1 | ScalarpduAdvSmsCtrl | read-write | mandatory | Enable/disable the SMS function. |
| 1.3.6.1.4.1.42610.1.4.1.1.7.2.2 | ScalarpduAdvSmsAuth | read-write | mandatory | Enable/disable the Authentication of SMS. |
| 1.3.6.1.4.1.42610.1.4.1.1.7.2.3 | ScalarpduAdvSmsPinCode | read-write | mandatory | The pin code of SMS, using base64(aes-cbc-256) encryption. |
| 1.3.6.1.4.1.42610.1.4.1.1.7.2.4 | TablepduAdvSmsTable | not-accessible | mandatory | A list of managers to send sms notification to. |
| 1.3.6.1.4.1.42610.1.4.1.1.7.2.4.1 | RowpduAdvSmsTblEntry | not-accessible | mandatory | The managers to send sms notification to. |
| 1.3.6.1.4.1.42610.1.4.1.1.7.2.4.1.1 | ColumnpduAdvSmsTblIndex | read-only | mandatory | The index to a sms notification receiver entry. |
| 1.3.6.1.4.1.42610.1.4.1.1.7.2.4.1.2 | ColumnpduAdvSmsTblPhone | read-write | mandatory | The phone number of SMS list. |
| 1.3.6.1.4.1.42610.1.4.1.1.7.2.4.1.3 | ColumnpduAdvSmsTblSeverity | read-write | mandatory | The severity level of SMS list. |
| 1.3.6.1.4.1.42610.1.4.1.1.7.2.4.1.4 | ColumnpduAdvSmsTblBody | read-write | mandatory | The prefix body of SMS list. |
| 1.3.6.1.4.1.42610.1.4.1.2 | NodepduTraps | |||
| 1.3.6.1.4.1.42610.1.4.1.2.1 | NodepduSystemColdBoot | Informational: Cold boot. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.2 | NodepduSystemWarmBoot | Informational: Warm boot. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.3 | NodepduSystemRestart | Informational: System restart. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.4 | NodepduResetToDefault | Informational: Parameters reset to default. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.6 | NodepduSystemLogClear | Informational: System log cleared. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.7 | NodepduEventlogClear | Informational: Event log cleared. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.8 | NodepduInletHistoryClear | Informational: Inlet history log cleared. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.9 | NodepduOutletHistoryClear | Informational: Outlet history log cleared. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.10 | NodepduEmdHistoryLogClear | Informational: EMD history log cleared. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.11 | NodepduSystemTimeChangeUser | Informational: Time changed by user. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.12 | NodepduSystemTimeChangeNtp | Informational: Time synced with NTP server. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.13 | NodepduSystemTimeChangeRtc | Informational: Time changed by RTC. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.14 | NodepduMailTestPass | Informational: Test mail pass. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.15 | NodepduMailTestFail | Informational: Test mail failed. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.16 | NodepduMailSentPass | Informational: Mail sent successfully. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.17 | NodepduMailSentFail | Informational: Mail sent failed. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.19 | NodepduSystemParamImport | Informational: Import XML configuration. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.20 | NodepduAccountResetDefault | Informational: The default accounts had been reset to default value. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.21 | NodepduGroupOutletChanged | Informational: The Administrator has changed the authority of Outlet Manager, the Grouping setting will be cleared synchronously. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.22 | NodepduScheduleOutletChanged | Informational: The Administrator has changed the authority of Outlet Manager, the Schedule setting will be cleared synchronously. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.23 | NodepduGroupChanged | Informational: The Outlet Manger has changed the setting of Outlet Grouping, the Schedule will be cleared synchronously. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.24 | NodepduSetUser | Informational: Assign outlet to user. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.25 | NodepduDeletUser | Informational: Delete user. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.26 | NodepduInletCommLost | Informational: PDU communication lost. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.27 | NodepduInletCommRestore | Informational: PDU communication restore. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.28 | NodepduUpgradeDevSuccess | Informational: Device upgrade successfully. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.29 | NodepduUpgradeDevFail | Informational: Device upgrade fail. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.30 | NodepduEmdComSuccess | Informational: EMD communication succeeded. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.31 | NodepduEmdComLost | Informational: EMD communication lost. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.32 | NodepduEmdUpdateSuccess | Informational: EMD Firmware update success. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.33 | NodepduEmdUpdateFail | Informational: EMD Firmware update fail. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.34 | NodepduSendTestTrap | Informational: Send test trap. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.54 | NodepduDaisyCommLost | Warning:Daisy chain communication lost. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.55 | NodepduDaisyCommRestore | Informational:Daisy chain communication restore. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.130 | NodepduInletLoadCritToWarn | Informational: Inlet load had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.131 | NodepduInletLoadCritical | Critical: Inlet load was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.132 | NodepduInletLoadWarnToNormal | Informational: Inlet load had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.133 | NodepduInletLoadWarn | Warning: Inlet load was higher than warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.134 | NodepduInletCurrPhase1CritToWarn | Informational: Inlet phase1 current had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.135 | NodepduInletCurrPhase1Critical | Critical: Inlet phase1 current was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.136 | NodepduInletCurrPhase1WarnToNormal | Informational: Inlet phase1 current had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.137 | NodepduInletCurrPhase1Warn | Warning: Inlet phase1 current was higher than warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.138 | NodepduInletCurrPhase2CritToWarn | Informational: Inlet phase2 current had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.139 | NodepduInletCurrPhase2Critical | Critical: Inlet phase2 current was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.140 | NodepduInletCurrPhase2WarnToNormal | Informational: Inlet phase2 current had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.141 | NodepduInletCurrPhase2Warn | Warning: Inlet phase2 current was higher than warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.142 | NodepduInletCurrPhase3CritToWarn | Informational: Inlet phase3 current had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.143 | NodepduInletCurrPhase3Critical | Critical: Inlet phase3 current was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.144 | NodepduInletCurrPhase3WarnToNprmal | Informational: Inlet phase3 current had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.145 | NodepduInletCurrPhase3Warn | Warning: Inlet phase3 current had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.146 | NodepduInletCurrPhase1CritToWarnB1 | Informational: Inlet phase1 current branch1 had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.147 | NodepduInletCurrPhase1CriticalB1 | Critical: Inlet phase1 current branch1 was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.148 | NodepduInletCurrPhase1WarnToNormalB1 | Informational: Inlet phase1 current branch1 had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.149 | NodepduInletCurrPhase1WarnB1 | Warning: Inlet phase1 current branch1 was higher than warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.150 | NodepduInletCurrPhase2CritToWarnB1 | Informational: Inlet phase2 current branch1 had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.151 | NodepduInletCurrPhase2CriticalB1 | Critical: Inlet phase2 current branch1 was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.152 | NodepduInletCurrPhase2WarnToNormalB1 | Informational: Inlet phase2 current branch1 had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.153 | NodepduInletCurrPhase2WarnB1 | Warning: Inlet phase2 current branch1 was higher than warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.154 | NodepduInletCurrPhase3CritToWarnB1 | Informational: Inlet phase3 current branch1 had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.155 | NodepduInletCurrPhase3CriticalB1 | Critical: Inlet phase3 current branch1 was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.156 | NodepduInletCurrPhase3WarnToNprmalB1 | Informational: Inlet phase3 current branch1 had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.157 | NodepduInletCurrPhase3WarnB1 | Warning: Inlet phase3 current branch1 had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.158 | NodepduInletCurrPhase1CritToWarnB2 | Informational: Inlet phase1 current branch2 had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.159 | NodepduInletCurrPhase1CriticalB2 | Critical: Inlet phase1 current branch2 was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.160 | NodepduInletCurrPhase1WarnToNormalB2 | Informational: Inlet phase1 current branch2 had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.161 | NodepduInletCurrPhase1WarnB2 | Warning: Inlet phase1 current branch2 was higher than warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.162 | NodepduInletCurrPhase2CritToWarnB2 | Informational: Inlet phase2 current branch2 had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.163 | NodepduInletCurrPhase2CriticalB2 | Critical: Inlet phase2 current branch2 was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.164 | NodepduInletCurrPhase2WarnToNormalB2 | Informational: Inlet phase2 current branch2 had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.165 | NodepduInletCurrPhase2WarnB2 | Warning: Inlet phase2 current branch2 was higher than warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.166 | NodepduInletCurrPhase3CritToWarnB2 | Informational: Inlet phase3 current branch2 had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.167 | NodepduInletCurrPhase3CriticalB2 | Critical: Inlet phase3 current branch2 was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.168 | NodepduInletCurrPhase3WarnToNprmalB2 | Informational: Inlet phase3 current branch2 had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.169 | NodepduInletCurrPhase3WarnB2 | Warning: Inlet phase3 current branch2 had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.170 | NodepduInletCurrPhase1CritToWarnTotal | Informational: Inlet phase1 current total had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.171 | NodepduInletCurrPhase1CriticalTotal | Critical: Inlet phase1 current total was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.172 | NodepduInletCurrPhase1WarnToNormalTotal | Informational: Inlet phase1 current total had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.173 | NodepduInletCurrPhase1WarnTotal | Warning: Inlet phase1 current total was higher than warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.174 | NodepduInletCurrPhase2CritToWarnTotal | Informational: Inlet phase2 current total had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.175 | NodepduInletCurrPhase2CriticalTotal | Critical: Inlet phase2 current total was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.176 | NodepduInletCurrPhase2WarnToNormalTotal | Informational: Inlet phase2 current total had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.177 | NodepduInletCurrPhase2WarnTotal | Warning: Inlet phase2 current total was higher than warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.178 | NodepduInletCurrPhase3CritToWarnTotal | Informational: Inlet phase3 current total had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.179 | NodepduInletCurrPhase3CriticalTotal | Critical: Inlet phase3 current total was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.180 | NodepduInletCurrPhase3WarnToNprmalTotal | Informational: Inlet phase3 current total had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.181 | NodepduInletCurrPhase3WarnTotal | Warning: Inlet phase3 current total had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.182 | NodepduInletVoltPhase1CritToWarn | Informational: Inlet phase1 voltage had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.183 | NodepduInletVoltPhase1Critical | Critical: Inlet phase1 voltage was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.184 | NodepduInletVoltPhase1WarnToNormal | Informational: Inlet phase1 voltage had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.185 | NodepduInletVoltPhase1Warn | Warning: Inlet phase1 voltage was higher than warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.186 | NodepduInletVoltPhase2CritToWarn | Informational: Inlet phase2 voltage had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.187 | NodepduInletVoltPhase2Critical | Critical: Inlet phase2 voltage was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.188 | NodepduInletVoltPhase2WarnToNormal | Informational: Inlet phase2 voltage had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.189 | NodepduInletVoltPhase2Warn | Warning: Inlet phase2 voltage was higher than warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.190 | NodepduInletVoltPhase3CritToWarn | Informational: Inlet phase3 voltage had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.191 | NodepduInletVoltPhase3Critical | Critical: Inlet phase3 voltage was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.192 | NodepduInletVoltPhase3WarnToNormal | Informational: Inlet phase3 voltage had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.193 | NodepduInletVoltPhase3Warn | Warning: Inlet phase3 voltage was higher than warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.194 | NodepduInletLoadBalanceCritToWarn | Informational: Inlet load balance had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.195 | NodepduInletLoadBalanceCritical | Critical: Inlet load balance was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.196 | NodepduInletLoadBalanceWarnToNormal | Informational: Inlet load balance had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.197 | NodepduInletLoadBalanceWarn | Warning: Inlet load balance was higher than warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.198 | NodepduOutletCurrCritToWarn | Informational: Outlet current had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.199 | NodepduOutletCurrCritical | Critical: Outlet current was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.200 | NodepduOutletCurrWarnToNormal | Informational: Outlet current had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.201 | NodepduOutletCurrWarn | Warning: Outlet current was higher than warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.202 | NodepduOutletPwrCritTOWarn | Informational: Outlet power had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.203 | NodepduOutletPwrCritical | Critical: Outlet power was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.204 | NodepduOutletPwrWarnToNormal | Informational: Outlet power had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.205 | NodepduOutletPwrWarn | Warning: Outlet power was higher than warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.206 | NodepduOutletOnUser | Informational: Outlet turned on by user. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.207 | NodepduOutletOnSchedule | Informational: Outlet turned on by schedule. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.208 | NodepduOutletOffUser | Informational: Outlet turned off by user. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.209 | NodepduOutletOffSchedule | Informational: Outlet turned off by schedule. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.210 | NodepduOutletRebootUser | Informational: Outlet reboot by user. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.211 | NodepduOutletRebootSchedule | Informational: Outlet reboot by schedule. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.212 | NodepduEmdTempHighWarnToNormal | Informational: Temperature had returned from high warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.213 | NodepduEmdTempHighWarn | Warning: Temperature was higher than high warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.214 | NodepduEmdTempLowWarnToNormal | Informational: Temperature had returned from low warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.215 | NodepduEmdTempLowWarn | Warning: Temperature was lower than low warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.216 | NodepduEmdTempHighCritToWarn | Informational: Temperature had returned from high critical to high warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.217 | NodepduEmdTempHighCritical | Critical: Temperature was higher than high critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.218 | NodepduEmdTempLowCritToWarn | Informational: Temperature had returned from low critical to low warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.219 | NodepduEmdTempLowCritical | Critical: Temperature was lower than low critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.220 | NodepduEmdHumiHighWarnToNormal | Informational: Humidity had returned from high warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.221 | NodepduEmdHumiHighWarn | Warning: Humidity was higher than high warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.222 | NodepduEmdHumiLowWarnToNormal | Informational: Humidity had returned from low warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.223 | NodepduEmdHumiLowWarn | Warning: Humidity was lower than low warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.224 | NodepduEmdHumiHighCritToWarn | Informational: Humidity had returned from high critical to high warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.225 | NodepduEmdHumiHighCritical | Critical: Humidity was higher than high critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.226 | NodepduEmdHumiLowCritToWarn | Informational: Humidity had returned from low critical to low warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.227 | NodepduEmdHumiLowCritical | Critical: Humidity was lower than low critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.228 | NodepduEmdAlarm1NotActive | Informational: Alarm-1 became inactive. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.229 | NodepduEmdAlarm1Active | Warning: Alarm-1 became active. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.230 | NodepduEmdAlarm2NotActive | Informational: Alarm-2 became inactive. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.231 | NodepduEmdAlarm2Active | Warning: Alarm-2 became active. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.232 | NodepduInletEnergyReset | Informational: Inlet energy reset. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.233 | NodepduInletEnergyResetPhase1 | Informational: Inlet phase1 energy reset. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.234 | NodepduInletEnergyResetPhase2 | Informational: Inlet phase2 energy reset. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.235 | NodepduInletEnergyResetPhase3 | Informational: Inlet phase3 energy reset. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.236 | NodepduOutletEnergyReset | Informational: Outlet energy reset. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.237 | NodepduIntetResidualCurrect1Occured | Critical: Inlet Residual current occurred. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.238 | NodepduIntetResidualCurrect1Remove | Informational: Inlet Residual current removed. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.239 | NodepduInletPfPhase1CritToWarnB1 | Informational: Inlet phase1 pf branch1 had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.240 | NodepduInletPfPhase1CriticalB1 | Critical: Inlet phase1 pf branch1 was lower than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.241 | NodepduInletPfPhase1WarnToNormalB1 | Informational: Inlet phase1 pf branch1 had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.242 | NodepduInletPfPhase1WarnB1 | Warning: Inlet phase1 pf branch1 was lower than warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.243 | NodepduInletPfPhase2CritToWarnB1 | Informational: Inlet phase2 pf branch1 had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.244 | NodepduInletPfPhase2CriticalB1 | Critical: Inlet phase2 pf branch1 was lower than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.245 | NodepduInletPfPhase2WarnToNormalB1 | Informational: Inlet phase2 pf branch1 had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.246 | NodepduInletPfPhase2WarnB1 | Warning: Inlet phase2 pf branch1 was lower than warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.247 | NodepduInletPfPhase3CritToWarnB1 | Informational: Inlet phase3 pf branch1 had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.248 | NodepduInletPfPhase3CriticalB1 | Critical: Inlet phase3 pf branch1 was lower than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.249 | NodepduInletPfPhase3WarnToNprmalB1 | Informational: Inlet phase3 pf branch1 had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.250 | NodepduInletPfPhase3WarnB1 | Warning: Inlet phase3 pf branch1 had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.251 | NodepduInletPfPhase1CritToWarnB2 | Informational: Inlet phase1 pf branch2 had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.252 | NodepduInletPfPhase1CriticalB2 | Critical: Inlet phase1 pf branch2 was lower than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.253 | NodepduInletPfPhase1WarnToNormalB2 | Informational: Inlet phase1 pf branch2 had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.254 | NodepduInletPfPhase1WarnB2 | Warning: Inlet phase1 pf branch2 was lower than warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.255 | NodepduInletPfPhase2CritToWarnB2 | Informational: Inlet phase2 pf branch2 had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.256 | NodepduInletPfPhase2CriticalB2 | Critical: Inlet phase2 pf branch2 was lower than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.257 | NodepduInletPfPhase2WarnToNormalB2 | Informational: Inlet phase2 pf branch2 had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.258 | NodepduInletPfPhase2WarnB2 | Warning: Inlet phase2 pf branch2 was lower than warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.259 | NodepduInletPfPhase3CritToWarnB2 | Informational: Inlet phase3 pf branch2 had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.260 | NodepduInletPfPhase3CriticalB2 | Critical: Inlet phase3 pf branch2 was lower than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.261 | NodepduInletPfPhase3WarnToNprmalB2 | Informational: Inlet phase3 pf branch2 had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.262 | NodepduInletPfPhase3WarnB2 | Warning: Inlet phase3 pf branch2 had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.263 | NodepduInletPowerShareMainLose | Warning: Active/Main Power change to Active/Backup Power. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.264 | NodepduInletPowerShareMainResotre | Informational: Active/Backup Power change to Active/Main Power. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.265 | NodepduInletPowerShareBackupLose | Warning: Active/Main Power change to Inactive. | ||
| 1.3.6.1.4.1.42610.1.4.1.2.266 | NodepduInletPowerShareBackupResotre | Informational: Inactive change to Active/Main Power Alarmstring. |