MIB Viewer

STONESOFT-NETNODE-MIB

44 objects
MIB for generic network nodes
Imported Objects
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIInteger32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCDateAndTime DisplayString TimeStamp
STONESOFT-SMI-MIBstonesoftModules stonesoftNetworkNode
OIDNameAccessStatusDescription
1.3.6.1.4.1.1369.3.4IdentitystonesoftNetworkNodeMibModuleMIB for generic network nodes
1.3.6.1.4.1.1369.6.1.1NodenetNodeObjects
1.3.6.1.4.1.1369.6.1.1.1ScalarnodeClusterIdread-onlycurrentThe identification number of the cluster this node belongs to
1.3.6.1.4.1.1369.6.1.1.2ScalarnodeMemberIdread-onlycurrentNode's member identification within the cluster
1.3.6.1.4.1.1369.6.1.1.3ScalarnodeOperStateread-onlycurrentThe operative (clustering) state of the node
1.3.6.1.4.1.1369.6.1.1.4ScalarnodeCPULoadread-onlycurrentThe CPU load percentage on the node
1.3.6.1.4.1.1369.6.1.1.5ScalarnodeLastLoginread-onlycurrentThe most recent login event on the node
1.3.6.1.4.1.1369.6.1.1.6ScalarnodeLastLoginTimeread-onlycurrentTimestamp of the most recent login event on the node
1.3.6.1.4.1.1369.6.1.1.7TablenodeTestTablenot-accessiblecurrentThis table contains an entry for each test instance that was configured to send a trap on test failure
1.3.6.1.4.1.1369.6.1.1.7.1RownodeTestEntrynot-accessiblecurrentRow for a test instance
1.3.6.1.4.1.1369.6.1.1.7.1.1ColumnnodeTestIndexnot-accessiblecurrentUnique positive integer index of the nodeTest instance
1.3.6.1.4.1.1369.6.1.1.7.1.2ColumnnodeTestIdentityread-onlycurrentIdentification string of a nodeTest
1.3.6.1.4.1.1369.6.1.1.7.1.3ColumnnodeTestResultread-onlycurrentThe most recent result of the nodeTest
1.3.6.1.4.1.1369.6.1.1.7.1.4ColumnnodeTestResultTimeread-onlycurrentThe timestamp of the most recent result of the nodeTest
1.3.6.1.4.1.1369.6.1.1.8ScalarnodeHwmonEventread-onlycurrentReason for the hardware monitoring event
1.3.6.1.4.1.1369.6.1.1.9ScalarnodeApplianceModelread-onlycurrentAppliance model name
1.3.6.1.4.1.1369.6.1.1.10ScalarnodeSerialNumberread-onlycurrentAppliance serial number
1.3.6.1.4.1.1369.6.1.1.11ScalarnodePosCoderead-onlycurrentAppliance POS code
1.3.6.1.4.1.1369.6.1.1.12ScalarnodeLoginTimeread-onlycurrentThe most recent login event on the node
1.3.6.1.4.1.1369.6.1.1.13ScalarnodePolicyApplyTimeread-onlycurrentThe time when the security policy was installed to the node
1.3.6.1.4.1.1369.6.1.2NodenetNodeEvents
1.3.6.1.4.1.1369.6.1.2.0NodenetNodeEventsV2
1.3.6.1.4.1.1369.6.1.2.0.1NotificationnodeOnlinecurrentA node has gone to an online state
1.3.6.1.4.1.1369.6.1.2.0.2NotificationnodeOfflinecurrentA node has gone to an offline or standby state
1.3.6.1.4.1.1369.6.1.2.0.3NotificationnodeBootcurrentA node has booted up
1.3.6.1.4.1.1369.6.1.2.0.4NotificationnodeShutdowncurrentA node is shutting down
1.3.6.1.4.1.1369.6.1.2.0.5NotificationnodeUserLogincurrentA user has started a login session
1.3.6.1.4.1.1369.6.1.2.0.6NotificationnodeTestFailurecurrentNodeTest has failed
1.3.6.1.4.1.1369.6.1.2.0.7NotificationnodeHwmoncurrentHardware monitoring system has detected problems
1.3.6.1.4.1.1369.6.1.2.0.8NotificationnodeFailedUserLogincurrentFailed user login
1.3.6.1.4.1.1369.6.1.2.0.9NotificationnodeUserLogoutcurrentA user has finished session
1.3.6.1.4.1.1369.6.1.3NodenetNodeConformance
1.3.6.1.4.1.1369.6.1.3.1NodenetNodeGroups
1.3.6.1.4.1.1369.6.1.3.1.1GroupnodeIdentificationGroupcurrentA collection of objects identifying the node in a cluster
1.3.6.1.4.1.1369.6.1.3.1.2GroupnodeStatusGroupcurrentA collection of objects giving information about the status of the node
1.3.6.1.4.1.1369.6.1.3.1.3GroupnodeLoginGroupcurrentA collection of objects giving information about logins into the node
1.3.6.1.4.1.1369.6.1.3.1.4GroupnodeTesterGroupcurrentA collection of objects giving information about the tests in the test subsystem of the node
1.3.6.1.4.1.1369.6.1.3.1.5GroupnodeStatusNotificationsGroupcurrentA collection of notifications informing about changes in a node's status
1.3.6.1.4.1.1369.6.1.3.1.6GroupnodeLoginNotificationsGroupcurrentA collection of notifications informing about user logins
1.3.6.1.4.1.1369.6.1.3.1.7GroupnodeTesterNotificationsGroupcurrentA collection of notifications informing about test failures
1.3.6.1.4.1.1369.6.1.3.1.8GroupnodeHwmonGroupcurrentA collection of objects giving information about hardware monitoring events in the node
1.3.6.1.4.1.1369.6.1.3.1.9GroupnodeHwmonNotificationsGroupcurrentA collection of notifications informing about hardware monitoring issues
1.3.6.1.4.1.1369.6.1.3.2NodenetNodeCompliances
1.3.6.1.4.1.1369.6.1.3.2.1CompliancenodeCompliance1currentThe compliance statement for network nodes