MIB Viewer

SUN-HW-CTRL-MIB

49 objects
SUN-HW-CTRL-MIB.mib Version 1.1 Copyright 2010, by Sun Microsystems, Inc. All rights reserved. Use is subject to license terms. This MIB allows controls for all Sun platform devices using Integrated Lights Out Management.
Imported Objects
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMPv2-CONFOBJECT-GROUP
SNMPv2-SMIenterprises Integer32 MODULE-IDENTITY OBJECT-TYPE
SNMPv2-TCDateAndTime TEXTUAL-CONVENTION TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.42Nodesun
1.3.6.1.4.1.42.2Nodeproducts
1.3.6.1.4.1.42.2.175Nodeilom
1.3.6.1.4.1.42.2.175.104IdentitysunHwCtrlMIBSUN-HW-CTRL-MIB.mib Version 1.1 Copyright 2010, by Sun Microsystems, Inc. All rights reserved. Use is subject to license terms. This MIB allows controls for al…
1.3.6.1.4.1.42.2.175.104.1NodesunHwCtrlMIBObjects
1.3.6.1.4.1.42.2.175.104.1.6NodesunHwCtrlPowerMgmt
1.3.6.1.4.1.42.2.175.104.1.6.1ScalarsunHwCtrlReservedPSUread-writecurrentThe number of Reserved PSU's.
1.3.6.1.4.1.42.2.175.104.1.6.2ScalarsunHwCtrlTotalPSUread-onlycurrentThe total number of PSU's.
1.3.6.1.4.1.42.2.175.104.1.6.3TablesunHwCtrlPowerMgmtTablenot-accessiblecurrentA table listing additional power management properties.
1.3.6.1.4.1.42.2.175.104.1.6.3.1RowsunHwCtrlPowerMgmtEntrynot-accessiblecurrentAn entry for a power management property.
1.3.6.1.4.1.42.2.175.104.1.6.3.1.1ColumnsunHwCtrlPowerMgmtIDnot-accessiblecurrentThis is an index for the sunHwCtrlPowerMgmtTable.
1.3.6.1.4.1.42.2.175.104.1.6.3.1.2ColumnsunHwCtrlPowerMgmtNameread-onlycurrentThis is the name of the power management property.
1.3.6.1.4.1.42.2.175.104.1.6.3.1.3ColumnsunHwCtrlPowerMgmtUnitsread-onlycurrentThis is the units for the value of the power management property.
1.3.6.1.4.1.42.2.175.104.1.6.3.1.4ColumnsunHwCtrlPowerMgmtValueread-onlycurrentThis is the value of the power management property.
1.3.6.1.4.1.42.2.175.104.1.6.4ScalarsunHwCtrlPowerMgmtActualPowerread-onlycurrentTotal input power consumed in watts. On a rackmount server, total power consumption is the input power consumed by the server. On a blade, this is the input po…
1.3.6.1.4.1.42.2.175.104.1.6.5ScalarsunHwCtrlPowerMgmtPermittedPowerread-onlycurrentMaximum input power consumption in watts. On a rackmount server, the maximum power consumption is the maximum input power the server guarantees it will consume…
1.3.6.1.4.1.42.2.175.104.1.6.6ScalarsunHwCtrlPowerMgmtAvailablePowerread-onlycurrentMaximum input power capacity in watts. Power capacity is the maximum input power the power supplies are capable of consuming. On a blade, this is the amount of…
1.3.6.1.4.1.42.2.175.104.1.6.7ScalarsunHwCtrlPowerMgmtPolicyread-writecurrentIndicates the desired power managment policy.
1.3.6.1.4.1.42.2.175.104.1.6.9NodesunHwCtrlPowerMgmtBudgetSettings
1.3.6.1.4.1.42.2.175.104.1.6.9.1ScalarsunHwCtrlPowerMgmtBudgetread-writecurrentWhen reading, the current state of the following budget settings: sunHwCtrlPowerMgmtBudgetMinPowerlimit sunHwCtrlPowerMgmtBudgetPowerlimit sunHwCtrlPowerMgmtBu…
1.3.6.1.4.1.42.2.175.104.1.6.9.2ScalarsunHwCtrlPowerMgmtBudgetMinPowerlimitread-onlycurrentMinimum value sunHwCtrlPowerMgmtBudgetPowerlimit can be set to. The power capper can control power consumption to fit within as little as this amount of power …
1.3.6.1.4.1.42.2.175.104.1.6.9.3ScalarsunHwCtrlPowerMgmtBudgetPowerlimitread-onlycurrentMaximum power consumption in watts.
1.3.6.1.4.1.42.2.175.104.1.6.9.5ScalarsunHwCtrlPowerMgmtBudgetTimelimitread-onlycurrentGrace period for exceeding the powerlimit once the powerlimit has been achieved, in milliseconds.
1.3.6.1.4.1.42.2.175.104.1.6.9.6ScalarsunHwCtrlPowerMgmtBudgetTimelimitActionsread-onlycurrentList of actions that will occur if the power limit is exceeded and cannot be controlled within the timelimit. hardpoweroff(1) causes a hard power off if the ti…
1.3.6.1.4.1.42.2.175.104.1.6.9.7ScalarsunHwCtrlPowerMgmtBudgetOKread-onlycurrent'true' if sunHwCtrlPowerMgmtBudget is 'disabled(2)'. If sunHwCtrlPowerMgmtBudget is 'enabled(3)', sunHwCtrlPowerMgmtBudgetOK will be 'false' if the power consu…
1.3.6.1.4.1.42.2.175.104.1.6.9.100ScalarsunHwCtrlPowerMgmtBudgetCommitPendingread-writecurrentCommits the following pending values: sunHwCtrlPowerMgmtBudgetPendingPowerlimit sunHwCtrlPowerMgmtBudgetPendingTimelimit sunHwCtrlPowerMgmtBudgetPendingTimelim…
1.3.6.1.4.1.42.2.175.104.1.6.9.103ScalarsunHwCtrlPowerMgmtBudgetPendingPowerlimitread-writecurrentWhen committed, the value is applied to sunHwCtrlPowerMgmtBudgetPowerlimit.
1.3.6.1.4.1.42.2.175.104.1.6.9.105ScalarsunHwCtrlPowerMgmtBudgetPendingTimelimitread-writecurrentWhen committed, the value is applied to sunHwCtrlPowerMgmtBudgetTimelimit. A value of -1 instructs the system to use its' default value.
1.3.6.1.4.1.42.2.175.104.1.6.9.106ScalarsunHwCtrlPowerMgmtBudgetPendingTimelimitActionsread-writecurrentWhen committed, the value is applied to sunHwCtrlPowerMgmtBudgetTimelimitActions.
1.3.6.1.4.1.42.2.175.104.1.6.10NodesunHwCtrlPowerMgmtConsumptionThresholds
1.3.6.1.4.1.42.2.175.104.1.6.10.1ScalarsunHwCtrlPowerMgmtConsumptionThreshold1read-writecurrentA threshold that determines if ILOM threshold events get generated based on the value of the system power consumption sensor (typically /SYS/VPS). Valid values…
1.3.6.1.4.1.42.2.175.104.1.6.10.2ScalarsunHwCtrlPowerMgmtConsumptionThreshold2read-writecurrentA threshold that determines if ILOM threshold events get generated based on the value of the system power consumption sensor (typically /SYS/VPS). Valid values…
1.3.6.1.4.1.42.2.175.104.1.6.11NodesunHwCtrlPowerMgmtSampling
1.3.6.1.4.1.42.2.175.104.1.6.11.1ScalarsunHwCtrlPowerMgmtSamplingPeriodread-writecurrentSampling period over which sunHwCtrlPowerMgmtSamplingMinimumPower, sunHwCtrlPowerMgmtSamplingMaximumPower and sunHwCtrlPowerMgmtSamplingAveragePower are calcul…
1.3.6.1.4.1.42.2.175.104.1.6.11.2ScalarsunHwCtrlPowerMgmtSamplingTimestampread-onlycurrentDate and time at which the power consumption values were calculated.
1.3.6.1.4.1.42.2.175.104.1.6.11.3ScalarsunHwCtrlPowerMgmtSamplingMinimumPowerread-onlycurrentMinimum measured power consumption during most recent sampling period, in watts
1.3.6.1.4.1.42.2.175.104.1.6.11.4ScalarsunHwCtrlPowerMgmtSamplingMaximumPowerread-onlycurrentMaximum measured power consumption during most recent sampling period, in watts
1.3.6.1.4.1.42.2.175.104.1.6.11.5ScalarsunHwCtrlPowerMgmtSamplingAveragePowerread-onlycurrentAverage measured power consumption during most recent sampling period, in watts
1.3.6.1.4.1.42.2.175.104.1.7NodesunHwCtrlTPM
1.3.6.1.4.1.42.2.175.104.1.7.1ScalarsunHwCtrlTpmEnableread-writecurrentsunHwCtrlTpmEnable is the principal control for any action being taken to change the access mode(s) of the TPM device. Any attempt to change sunHwCtrlTpmEnable…
1.3.6.1.4.1.42.2.175.104.1.7.2ScalarsunHwCtrlTpmActivateread-writecurrentIf sunHwCtrlTpmActivate and sunHwCtrlTpmEnable are both currently true(1) during a host power on event, the TPM device will be enabled and activated. If sunHwC…
1.3.6.1.4.1.42.2.175.104.1.7.3ScalarsunHwCtrlTpmForceClearread-writecurrentIf sunHwCtrlTpmForceClear and sunHwCtrlTpmEnable are both currently true(1) during a host power on event, the TPM device state will be purged and the state of …
1.3.6.1.4.1.42.2.175.104.2NodesunHwCtrlMIBConformances
1.3.6.1.4.1.42.2.175.104.2.1NodesunHwCtrlCompliances
1.3.6.1.4.1.42.2.175.104.2.2NodesunHwCtrlGroups
1.3.6.1.4.1.42.2.175.104.2.2.1GroupsunHwCtrlObjectsGroupcurrentThe group of current objects.
Type Definitions
NameSyntaxStatusDescription
SunHwCtrlPowerMgmtBudgetTimelimitActionsBITS { none(0), hardPowerOff(1) }currentThe list of actions that will occur if the power limit is exceeded and cannot be controlled within the time limits SunHwCtrlPowerMgmtBudgetTimelimit
SunHwCtrlPowerMgmtIDInteger32 (1..2147483647)currentAn arbitrary value which uniquely identifies the power management table index. The value should be a small positive integer; index values for different policy entities are not necessarily contiguous.
SunHwCtrlPowerMgmtPolicyINTEGER { notsupported(1), unknown(2), performance(3), elastic(4) }currentAn enumerated value which describes the defined power management policies available. A value of notsupported(1) indicates that the control is not available on the managed platform. A value of unknown(2) indicates that t…