MIB Viewer

SUPERMICRO-HEALTH-MIB

21 objects
MIB module for monitoring health information
Imported Objects
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMIGauge32 Integer32 MODULE-IDENTITY OBJECT-TYPE
SNMPv2-TCDisplayString TEXTUAL-CONVENTION TruthValue
SUPERMICRO-SMIsmHealth
OIDNameAccessStatusDescription
1.3.6.1.4.1.10876.2.1IdentitysmHealthMIBMIB module for monitoring health information
1.3.6.1.4.1.10876.2.1.1NodesmHealthObjects
1.3.6.1.4.1.10876.2.1.1.1TablesmHealthMonitorTablenot-accessiblecurrentA table of health monitoring entries.
1.3.6.1.4.1.10876.2.1.1.1.1RowsmHealthMonitorEntrynot-accessiblecurrentAn entry in the health monitoring table. Entries cannot be created or deleted via SNMP operations.
1.3.6.1.4.1.10876.2.1.1.1.1.1ColumnsmHealthMonitorIndexnot-accessiblecurrentThe unique value which identifies this Monitor device.
1.3.6.1.4.1.10876.2.1.1.1.1.2ColumnsmHealthMonitorNameread-onlycurrentA textual full name assigned to the Monitor device. This object is suitable for output to a human operator.
1.3.6.1.4.1.10876.2.1.1.1.1.3ColumnsmHealthMonitorTyperead-onlycurrentIdentifies this Monitor device type.
1.3.6.1.4.1.10876.2.1.1.1.1.4ColumnsmHealthMonitorReadingread-onlycurrentIndicates the value from the Monitor device that are currently in use on the managed device. FAN reading is in unit of RPM, Voltage reading is in unit of mV, T…
1.3.6.1.4.1.10876.2.1.1.1.1.5ColumnsmHealthMonitorHighLimitread-writecurrentIndicates the value for the High limitation for the Monitor device that are currently in use on the managed device. Apply to Temperature and Voltage deivces on…
1.3.6.1.4.1.10876.2.1.1.1.1.6ColumnsmHealthMonitorLowLimitread-writecurrentIndicates the value for the Low limitation for the Monitor device that are currently in use on the managed device. FAN limit is in unit of RPM, Voltage limit i…
1.3.6.1.4.1.10876.2.1.1.1.1.7ColumnsmHealthMonitorMaxReadingread-onlycurrentIndicates the value for the possible Maximum reading value for the Monitor device that are currently in use on the managed device. FAN reading is in unit of RP…
1.3.6.1.4.1.10876.2.1.1.1.1.8ColumnsmHealthMonitorMinReadingread-onlycurrentIndicates the value for the possible Minimum reading value for the Monitor device that are currently in use on the managed device. FAN reading is in unit of RP…
1.3.6.1.4.1.10876.2.1.1.1.1.9ColumnsmHealthMonitorDivisorread-writecurrentIndicates the value for the Divisor for the Fan device that are currently in use on the managed device. Apply to Fan devices only.
1.3.6.1.4.1.10876.2.1.1.1.1.10ColumnsmHealthMonitorMonitorread-writecurrentIndicates the monitoring status for the Fan device that are currently in use on the managed device. 1 = monitor, 2=do not monitor
1.3.6.1.4.1.10876.2.1.2NodesmHealthNotifications
1.3.6.1.4.1.10876.2.1.3NodesmHealthConformance
1.3.6.1.4.1.10876.2.1.3.1NodesmHealthCompliances
1.3.6.1.4.1.10876.2.1.3.1.1CompliancesmHealthCompliancecurrentThe compliance statement for entities which implement the Supermicro Health Monitoring MIB
1.3.6.1.4.1.10876.2.1.3.2NodesmHealthGroups
1.3.6.1.4.1.10876.2.1.3.2.1GroupsmHealthMonitorGroupcurrentA collection of objects providing Monitor devices.
Type Definitions
NameSyntaxStatusDescription
SMHealthInfoTypesInteger32 (0..64)currentRepresents the different types of health information that may be present in a managed device. The following health information types are currently predefined: 0: fan speed 1: voltage 2: temperature