MIB Viewer

SUPERMICRO-RM-TE-LINK-MIB

46 objects
All rights reserved
Imported Objects
IF-MIBifIndex InterfaceIndexOrZero
SNMPv2-SMIenterprises IpAddress MODULE-IDENTITY OBJECT-TYPE Unsigned32
SNMPv2-TCRowStatus TEXTUAL-CONVENTION
OIDNameAccessStatusDescription
1.3.6.1.4.1.10876.101.1.10IdentityfutRMTeAll rights reserved
1.3.6.1.4.1.10876.101.1.10.0NodefutRMTeLinkNotifications
1.3.6.1.4.1.10876.101.1.10.1NodefutRMTeLinkObjects
1.3.6.1.4.1.10876.101.1.10.1.1NodefutRmTeLinkGeneralGroup
1.3.6.1.4.1.10876.101.1.10.1.1.1ScalarfutRmTeLinkRegDeregistrationread-writecurrentThis specific scalar object is for RM(Resource Manager) module to register/deregister itself with the OSPF-TE module to provide link/interface information.
1.3.6.1.4.1.10876.101.1.10.1.2TablefutRMTeLinkTablenot-accessiblecurrentThis table specifies the grouping of characteristics/attributes of TE links.
1.3.6.1.4.1.10876.101.1.10.1.2.1RowfutRMTeLinkEntrynot-accessiblecurrentAn entry in this table exists for each ifEntry with an ifType of futRMTeLink(200), i.e. for every TE link. An ifEntry in the ifTable must exist before a futRMT…
1.3.6.1.4.1.10876.101.1.10.1.2.1.1ColumnfutRMTeLinkLocalIpAddrread-createcurrentThe local Internet address for numbered links. For an unnumbered link, the local address is of type unknown and this object is set to the zero length string an…
1.3.6.1.4.1.10876.101.1.10.1.2.1.2ColumnfutRMTeLinkRemoteIpAddrread-createcurrentThe remote Internet address for numbered links. The remote IP address associated with the TE link (IPv4). For an unnumbered link, the remote address is of type…
1.3.6.1.4.1.10876.101.1.10.1.2.1.3ColumnfutRMTeLinkRemoteRtrIdread-createcurrentThis object identifies the routerId of the router/device at the other end of the link. This is useful in the case of FA-TE links where it is not possible to ge…
1.3.6.1.4.1.10876.101.1.10.1.2.1.4ColumnfutRMTeLinkMetricread-createcurrentThe traffic engineering metric for the TE link.
1.3.6.1.4.1.10876.101.1.10.1.2.1.5ColumnfutRMTeLinkProtectionTyperead-createcurrentThis attribute specifies link protection type of the TE link. Description of the different protection types can be found in the 'Routing Extensions in Support …
1.3.6.1.4.1.10876.101.1.10.1.2.1.6ColumnfutRMTeLinkResourceClassread-createcurrentThis attribute specifies the TE link resource class. The resource class is a 32 bit bitfield. Encoding of the resource class is described in the 'Traffic Engin…
1.3.6.1.4.1.10876.101.1.10.1.2.1.7ColumnfutRMTeLinkIncomingIfIdread-createcurrentFor unnumbered links, the incoming interface is set to the outgoing interface identifier chosen by the neighboring LSR for the reverse link corresponding to th…
1.3.6.1.4.1.10876.101.1.10.1.2.1.8ColumnfutRMTeLinkOutgoingIfIdread-createcurrentIf the link is unnumbered, the outgoing interface identifier is set to the outgoing interface identifier chosen for the TE link by the advertising LSR. For num…
1.3.6.1.4.1.10876.101.1.10.1.2.1.9ColumnfutRMTeLinkMaxBwread-createcurrentMaximum Bandwidth of the TE Link
1.3.6.1.4.1.10876.101.1.10.1.2.1.10ColumnfutRMTeLinkMaxResBwread-createcurrentMaximum Reservable Bandwidth of the TE Link
1.3.6.1.4.1.10876.101.1.10.1.2.1.11ColumnfutRMTeLinkAreaIdread-createcurrentAreaId of the area to which this TE link belongs to. For forwarding adjacency link this variable must be set to indicate the area id of the TE link.
1.3.6.1.4.1.10876.101.1.10.1.2.1.12ColumnfutRMTeLinkInfoTyperead-createcurrentThis is to indicate the link information type. This information is very crucial for proper generation of Traffic Engineering LSAs. areaIdInfo Resource Manager …
1.3.6.1.4.1.10876.101.1.10.1.2.1.13ColumnfutRMTeLinkRowStatusread-createcurrentThis variable is used to create, modify, and/or delete a row in this table.
1.3.6.1.4.1.10876.101.1.10.1.3TablefutRMTeLinkSwDescriptorTablenot-accessiblecurrentThis table specifies the link descriptors associated with the TE links.
1.3.6.1.4.1.10876.101.1.10.1.3.1RowfutRMTeLinkSwDescriptorEntrynot-accessiblecurrentAn entry in this table is created for every TE link descriptor. An ifEntry in the ifTable must exist before a futRMTeLinkDescriptorEntry using the same ifIndex…
1.3.6.1.4.1.10876.101.1.10.1.3.1.1ColumnfutRMTeLinkSwDescriptorIdnot-accessiblecurrentThis object specifies the link descriptor identifier.
1.3.6.1.4.1.10876.101.1.10.1.3.1.2ColumnfutRMTeLinkSwDescrSwitchingCapread-createcurrentThis attribute specifies the TE link switching capability information.
1.3.6.1.4.1.10876.101.1.10.1.3.1.3ColumnfutRMTeLinkSwDescrEncodingTyperead-createcurrentThis attribute specifies the TE link encoding type.
1.3.6.1.4.1.10876.101.1.10.1.3.1.4ColumnfutRMTeLinkSwDescrMinLSPBandwidthread-createcurrentThis attribute specifies the minimum reservable bandwidth on the TE link.
1.3.6.1.4.1.10876.101.1.10.1.3.1.5ColumnfutRMTeLinkSwDescrMTUread-createcurrentThis attribute specifies the maximum MTU size to use on this link for forwarding data packets.
1.3.6.1.4.1.10876.101.1.10.1.3.1.6ColumnfutRMTeLinkSwDescrIndicationread-createcurrentThis attribute indicates whether the interface supports standard or arbitrary SONET/SDH is encoded in 1 octet field. This is 0 if the interface supports standa…
1.3.6.1.4.1.10876.101.1.10.1.3.1.7ColumnfutRMTeLinkSwDescrRowStatusread-createcurrentThis variable is used to create, modify, and/or delete a row in this table. No read-create object can be changed if futRMTeLinkDescrRowStatus is in active(1) s…
1.3.6.1.4.1.10876.101.1.10.1.4TablefutRMTeLinkSwDescrMaxBwTablenot-accessiblecurrentThis table specifies the link Maxbandwidths associated with the TE links.
1.3.6.1.4.1.10876.101.1.10.1.4.1RowfutRMTeLinkSwDescrMaxBwEntrynot-accessiblecurrentAn entry in this table is created for each TE link interface. An ifEntry in the ifTable must exist before a futRMTeLinkSwDescrMaxBwEntry using the same ifIndex…
1.3.6.1.4.1.10876.101.1.10.1.4.1.1ColumnfutRMTeLinkSwDescrMaxBwPrioritynot-accessiblecurrentThis object specifies priority at which this MaxLSPBandwidth is available.
1.3.6.1.4.1.10876.101.1.10.1.4.1.2ColumnfutRMTeLinkSwDescrMaxLSPBandwidthread-createcurrentThis attribute specifies the Maximum Link Bandwidth of the TE link. Maximum LSP bandwidth is carried per priority, and may vary as LSPs are set up and torn dow…
1.3.6.1.4.1.10876.101.1.10.1.4.1.3ColumnfutRMTeLinkSwDescrMaxBwRowStatusread-createcurrentThis variable is used to create, modify, and/or delete a row in this table. No read-create object can be changed if futRMTeLinkSwDescrMaxBwRowStatus is in acti…
1.3.6.1.4.1.10876.101.1.10.1.5TablefutRMTeLinkSrlgTablenot-accessiblecurrentThis table specifies the SRLGs associated with TE links.
1.3.6.1.4.1.10876.101.1.10.1.5.1RowfutRMTeLinkSrlgEntrynot-accessiblecurrentAn entry in this table contains information about a SRLG associated with a TE link. An ifEntry in the ifTable must exist before a futRMTeLinkSrlgEntry using th…
1.3.6.1.4.1.10876.101.1.10.1.5.1.1ColumnfutRMTeLinkSrlgnot-accessiblecurrentThis identifies a SRLG supported by the TE link. An SRLG is identified with a 32 bit number that is unique within an IGP domain. Zero is a valid SRLG number.
1.3.6.1.4.1.10876.101.1.10.1.5.1.2ColumnfutRMTeLinkSrlgRowStatusread-createcurrentThis variable is used to create, modify, and/or delete a row in this table. No read-create object can be modified if futRMTeLinkSrlgRowStatus is active(1).
1.3.6.1.4.1.10876.101.1.10.1.6TablefutRMTeLinkBandwidthTablenot-accessiblecurrentThis table specifies the priority-based bandwidth table for TE links.
1.3.6.1.4.1.10876.101.1.10.1.6.1RowfutRMTeLinkBandwidthEntrynot-accessiblecurrentAn entry in this table contains information about the priority-based bandwidth of TE links. An ifEntry in the ifTable must exist before a futRMTeLinkBandwidthE…
1.3.6.1.4.1.10876.101.1.10.1.6.1.1ColumnfutRMTeLinkBandwidthPrioritynot-accessiblecurrentThis attribute specifies the priority. A value of 0 is valid as specified in the 'Traffic Engineering Extensions to OSPF Version 2' document.
1.3.6.1.4.1.10876.101.1.10.1.6.1.2ColumnfutRMTeLinkUnreservedBandwidthread-createcurrentThis attribute specifies the TE link unreserved bandwidth at priority p.
1.3.6.1.4.1.10876.101.1.10.1.6.1.3ColumnfutRMTeLinkBandwidthRowStatusread-createcurrentThis variable is used to create, modify, and/or delete a row in this table. No read-create object can be modified when futRMTeLinkBandwidthRowStatus is active(…
1.3.6.1.4.1.10876.101.1.10.2NodefutRMTeLinkConformance
Type Definitions
NameSyntaxStatusDescription
TeLinkEncodingTypeINTEGER { packet(1), ethernet(2), ansiEtsiPdh(3), sdhItuSonetAnsi(5), digitalWrapper(7), lambda(8), fiber(9), fiberChannel(11) }currentLink encoding type as specified in 'GMPLS Signaling Functional Description' document. The values specified in this document are not contiguous.
TeLinkPriorityUnsigned32 (0..7)currentThis type is used to represent a priority. Each connection is assigned a priority. This priority is used when accounting for bandwidth on TE links or component links, for resource allocation and for rerouting purposes. …