MIB Viewer

SUPERMICRO-SD5-MIB

223 objects
MIB module for sd5 information
Imported Objects
SNMPv2-SMIInteger32 MODULE-IDENTITY OBJECT-TYPE
SNMPv2-TCDisplayString
SUPERMICRO-SMIsmSSMInfo
OIDNameAccessStatusDescription
1.3.6.1.4.1.10876.100.1IdentitysmSuperDoctor5MIBMIB module for sd5 information
1.3.6.1.4.1.10876.100.1.1Tablesd5Tablenot-accessiblecurrentA table of sd5 entries.
1.3.6.1.4.1.10876.100.1.1.1Rowsd5Entrynot-accessiblecurrentAn entry in the sd5 table. Entries cannot be created or deleted via SNMP operations.
1.3.6.1.4.1.10876.100.1.1.1.1Columnsd5Idxread-onlycurrentThe unique value identifies this sd5.
1.3.6.1.4.1.10876.100.1.1.1.2Columnsd5Versionread-onlycurrentThe version of the sd5.
1.3.6.1.4.1.10876.100.1.1.1.3Columnsd5MIBVersionread-onlycurrentThe MIB version of the sd5.
1.3.6.1.4.1.10876.100.1.2TablecpuTablenot-accessiblecurrentA table of processor entries.
1.3.6.1.4.1.10876.100.1.2.1RowcpuEntrynot-accessiblecurrentAn entry in the processor table. Entries cannot be created or deleted via SNMP operations.
1.3.6.1.4.1.10876.100.1.2.1.1ColumncpuIndexread-onlycurrentThe unique value which identifies this processor.
1.3.6.1.4.1.10876.100.1.2.1.2ColumncpuNameread-onlycurrentThe name of the processor.
1.3.6.1.4.1.10876.100.1.2.1.3ColumncpuDescriptionread-onlycurrentThe description of the processor.
1.3.6.1.4.1.10876.100.1.2.1.4ColumncpuManufacturerread-onlycurrentThe manufacturer of the processor.
1.3.6.1.4.1.10876.100.1.2.1.5ColumncpuDeviceStatusread-onlycurrentThe status of the processor. The status depends on the cpu failure check via BIOS. 0: OK 2: Critical
1.3.6.1.4.1.10876.100.1.2.1.6ColumncpuMaxSpeedread-onlycurrentThe maximum speed (MHz) of the processor.
1.3.6.1.4.1.10876.100.1.2.1.7ColumncpuCurrentSpeedread-onlycurrentThe current speed (MHz) of the processor.
1.3.6.1.4.1.10876.100.1.2.1.9ColumncpuLoadingPercentageread-onlycurrentThe loading percentage of the processor.
1.3.6.1.4.1.10876.100.1.2.1.10ColumncpuCoreEnabledread-onlycurrentThe core enabled count of the processor.
1.3.6.1.4.1.10876.100.1.2.1.11ColumncpuCoreCountread-onlycurrentThe core count of the processor.
1.3.6.1.4.1.10876.100.1.2.1.12ColumncpuThreadCountread-onlycurrentThe thread count of the processor.
1.3.6.1.4.1.10876.100.1.2.1.14ColumncpuSocketDesignationread-onlycurrentThe socket designation of the processor.
1.3.6.1.4.1.10876.100.1.2.1.18ColumncpuDeviceVersionread-onlycurrentThe device version of the processor.
1.3.6.1.4.1.10876.100.1.2.1.20ColumncpuDeviceIDread-onlycurrentThe device ID of the processor.
1.3.6.1.4.1.10876.100.1.2.1.21ColumncpuIDread-onlycurrentThe ID of the processor.
1.3.6.1.4.1.10876.100.1.3TablememTablenot-accessiblecurrentA table of physical memory entries.
1.3.6.1.4.1.10876.100.1.3.1RowmemEntrynot-accessiblecurrentAn entry in the physical memory table. Entries cannot be created or deleted via SNMP operations.
1.3.6.1.4.1.10876.100.1.3.1.1ColumnmemTagread-onlycurrentThe tag of the physical memory. The unique value identifies this physical memory.
1.3.6.1.4.1.10876.100.1.3.1.2ColumnmemDescriptionread-onlycurrentThe description of the physical memory.
1.3.6.1.4.1.10876.100.1.3.1.3ColumnmemDeviceStatusread-onlycurrentIndicates the status of the physical memory. The status depends on the ECC check result on the physical memory. 0: OK 2: Critical
1.3.6.1.4.1.10876.100.1.3.1.4ColumnmemLabeledBankread-onlycurrentThe labeled bank of the physical memory.
1.3.6.1.4.1.10876.100.1.3.1.5ColumnmemDeviceLocatorread-onlycurrentThe device locator of the physical memory.
1.3.6.1.4.1.10876.100.1.3.1.7ColumnmemModelread-onlycurrentThe model name of the physical memory.
1.3.6.1.4.1.10876.100.1.3.1.8ColumnmemManufacturerread-onlycurrentThe manufacturer's name of the physical memory.
1.3.6.1.4.1.10876.100.1.3.1.9ColumnmemPartNumberread-onlycurrentThe part number of the physical memory.
1.3.6.1.4.1.10876.100.1.3.1.10ColumnmemSerialNumberread-onlycurrentThe serial number of the physical memory.
1.3.6.1.4.1.10876.100.1.3.1.11ColumnmemCapacityread-onlycurrentThe capacity of the physical memory. (Unit: MB)
1.3.6.1.4.1.10876.100.1.3.1.12ColumnmemDataWidthread-onlycurrentThe data width of the physical memory. (Unit: bit)
1.3.6.1.4.1.10876.100.1.3.1.13ColumnmemTotalWidthread-onlycurrentThe total width of the physical memory. (Unit: bit)
1.3.6.1.4.1.10876.100.1.3.1.15ColumnmemErrorCountread-onlycurrentThe error count of the physical memory. It's the summary of the ECC error count and UECC error count.
1.3.6.1.4.1.10876.100.1.3.1.16ColumnmemECCErrorCountread-onlycurrentThe ECC error count of the physical memory.
1.3.6.1.4.1.10876.100.1.3.1.17ColumnmemUECCErrorCountread-onlycurrentThe UECC error count of the physical memory.
1.3.6.1.4.1.10876.100.1.4TablediskTablenot-accessiblecurrentA table of physical disk entries.
1.3.6.1.4.1.10876.100.1.4.1RowdiskEntrynot-accessiblecurrentAn entry in the physical disk table. Entries cannot be created or deleted via SNMP operations.
1.3.6.1.4.1.10876.100.1.4.1.1ColumndiskSerialNumberread-onlycurrentThe serial number of the disk.
1.3.6.1.4.1.10876.100.1.4.1.2ColumndiskNameread-onlycurrentThe name of the disk. The unique value identifies this disk.
1.3.6.1.4.1.10876.100.1.4.1.3ColumndiskVendorread-onlycurrentThe vendor name of the disk.
1.3.6.1.4.1.10876.100.1.4.1.4ColumndiskSmartStatusread-onlycurrentIndicates the status of the disk. The status depends on the SMART check result on the disk. 0: OK 2: Critical
1.3.6.1.4.1.10876.100.1.4.1.5ColumndiskModelread-onlycurrentThe model of the disk.
1.3.6.1.4.1.10876.100.1.4.1.6ColumndiskSizeread-onlycurrentThe size of the disk. (Unit: MB)
1.3.6.1.4.1.10876.100.1.4.1.8ColumndiskMediaTyperead-onlycurrentThe media type of the disk includes External hard disk media Removable media other than floppy Fixed hard disk media and Unknown format
1.3.6.1.4.1.10876.100.1.4.1.9ColumndiskInterfaceTyperead-onlycurrentThe disk interface types includes IDE, HDC, USB, and SCSI.
1.3.6.1.4.1.10876.100.1.4.1.10ColumndiskControllerread-onlycurrentThe controller name of the disk.
1.3.6.1.4.1.10876.100.1.4.1.11ColumndiskSlotIDread-onlycurrentThe Slot ID of the disk.
1.3.6.1.4.1.10876.100.1.5TablesysBIOSTablenot-accessiblecurrentA table of System BIOS entries.
1.3.6.1.4.1.10876.100.1.5.1RowsysBIOSEntrynot-accessiblecurrentAn entry in the System BIOS table. Entries cannot be created or deleted via SNMP operations.
1.3.6.1.4.1.10876.100.1.5.1.1ColumnsysBIOSIndexread-onlycurrentThe unique value identifies this BIOS.
1.3.6.1.4.1.10876.100.1.5.1.7ColumnsysBIOSReleaseDateread-onlycurrentThe release date of BIOS.
1.3.6.1.4.1.10876.100.1.5.1.8ColumnsysBIOSVersionread-onlycurrentThe version of BIOS.
1.3.6.1.4.1.10876.100.1.5.1.11ColumnsysBIOSManufacturerread-onlycurrentThe manufacturer's name of BIOS.
1.3.6.1.4.1.10876.100.1.6TablembTablenot-accessiblecurrentA table of baseboard entries.
1.3.6.1.4.1.10876.100.1.6.1RowmbEntrynot-accessiblecurrentAn entry in the baseboard table. Entries cannot be created or deleted via SNMP operations.
1.3.6.1.4.1.10876.100.1.6.1.1ColumnmbIndexread-onlycurrentThe unique value identifies this baseboard.
1.3.6.1.4.1.10876.100.1.6.1.10ColumnmbManufacturerread-onlycurrentThe manufacturer's name of the baseboard.
1.3.6.1.4.1.10876.100.1.6.1.11ColumnmbProductNameread-onlycurrentThe product name of the baseboard.
1.3.6.1.4.1.10876.100.1.6.1.12ColumnmbVersionNameread-onlycurrentThe version of the baseboard.
1.3.6.1.4.1.10876.100.1.6.1.15ColumnmbAssetTagread-onlycurrentThe asset tag of the baseboard.
1.3.6.1.4.1.10876.100.1.6.1.16ColumnmbSerialNumberread-onlycurrentThe serial number of the baseboard.
1.3.6.1.4.1.10876.100.1.7TableosTablenot-accessiblecurrentA table of operation system entries.
1.3.6.1.4.1.10876.100.1.7.1RowosEntrynot-accessiblecurrentAn entry in the operation system table. Entries cannot be created or deleted via SNMP operations.
1.3.6.1.4.1.10876.100.1.7.1.1ColumnosIndexread-onlycurrentThe unique value identifies this Operation System.
1.3.6.1.4.1.10876.100.1.7.1.6ColumnosNameread-onlycurrentThe name of the Operation System.
1.3.6.1.4.1.10876.100.1.7.1.7ColumnosVersionread-onlycurrentThe version of the operation system.
1.3.6.1.4.1.10876.100.1.7.1.8ColumnosManufacturerread-onlycurrentThe manufacturer's name of the Operation System.
1.3.6.1.4.1.10876.100.1.7.1.9ColumnosSerialNumberread-onlycurrentThe serial number of the operation system.
1.3.6.1.4.1.10876.100.1.7.1.10ColumnosCSDVersionread-onlycurrentThe CSD version of the operation system.
1.3.6.1.4.1.10876.100.1.8NodedmiLogTable
1.3.6.1.4.1.10876.100.1.8.1TablececcLogTablenot-accessiblecurrentA table of operation system entries.
1.3.6.1.4.1.10876.100.1.8.1.1RowceccLogEntrynot-accessiblecurrentAn entry in the operation system table. Entries cannot be created or deleted via SNMP operations.
1.3.6.1.4.1.10876.100.1.8.1.1.1ColumnceccLogDatetimeread-onlycurrentThe CSD version of the operation system.
1.3.6.1.4.1.10876.100.1.8.1.1.2ColumnceccLogInforead-onlycurrentThe CSD version of the operation system.
1.3.6.1.4.1.10876.100.1.8.1.1.10ColumnceccLogIndexread-onlycurrentThe CSD version of the operation system.
1.3.6.1.4.1.10876.100.1.8.2TableueccLogTablenot-accessiblecurrentA table of operation system entries.
1.3.6.1.4.1.10876.100.1.8.2.1RowueccLogEntrynot-accessiblecurrentAn entry in the operation system table. Entries cannot be created or deleted via SNMP operations.
1.3.6.1.4.1.10876.100.1.8.2.1.1ColumnueccLogDatetimeread-onlycurrentThe CSD version of the operation system.
1.3.6.1.4.1.10876.100.1.8.2.1.2ColumnueccLogInforead-onlycurrentThe CSD version of the operation system.
1.3.6.1.4.1.10876.100.1.8.2.1.10ColumnueccLogIndexread-onlycurrentThe CSD version of the operation system.
1.3.6.1.4.1.10876.100.1.8.8TablepostLogTablenot-accessiblecurrentA table of operation system entries.
1.3.6.1.4.1.10876.100.1.8.8.1RowpostLogEntrynot-accessiblecurrentAn entry in the operation system table. Entries cannot be created or deleted via SNMP operations.
1.3.6.1.4.1.10876.100.1.8.8.1.1ColumnpostLogDatetimeread-onlycurrentThe CSD version of the operation system.
1.3.6.1.4.1.10876.100.1.8.8.1.2ColumnpostLogInforead-onlycurrentThe CSD version of the operation system.
1.3.6.1.4.1.10876.100.1.8.8.1.10ColumnpostLogIndexread-onlycurrentThe CSD version of the operation system.
1.3.6.1.4.1.10876.100.1.8.11TablecpuLogTablenot-accessiblecurrentA table of operation system entries.
1.3.6.1.4.1.10876.100.1.8.11.1RowcpuLogEntrynot-accessiblecurrentAn entry in the operation system table. Entries cannot be created or deleted via SNMP operations.
1.3.6.1.4.1.10876.100.1.8.11.1.1ColumncpuLogDatetimeread-onlycurrentThe CSD version of the operation system.
1.3.6.1.4.1.10876.100.1.8.11.1.2ColumncpuLogInforead-onlycurrentThe CSD version of the operation system.
1.3.6.1.4.1.10876.100.1.8.11.1.10ColumncpuLogIndexread-onlycurrentThe CSD version of the operation system.
1.3.6.1.4.1.10876.100.1.9TableraidAdapterTablenot-accessiblecurrentA table of raid controller entries.
1.3.6.1.4.1.10876.100.1.9.1RowraidAdapterEntrynot-accessiblecurrentAn entry in the raid controller table. Entries cannot be created or deleted via SNMP operations.
1.3.6.1.4.1.10876.100.1.9.1.1ColumnraidAdapterIndexread-onlycurrentRaid controller index. The unique value which identifies this raid controller.
1.3.6.1.4.1.10876.100.1.9.1.2ColumnraidAdapterGroupread-onlycurrentThe group of the raid controller. Values: LSI-MegaRAID LSI-Fusion-MPT
1.3.6.1.4.1.10876.100.1.9.1.3ColumnraidAdapterIdread-onlycurrentThe id of the raid controller. The id is unique in one adapter group.
1.3.6.1.4.1.10876.100.1.9.1.4ColumnraidAdapterProductNameread-onlycurrentThe product name of the raid controller.
1.3.6.1.4.1.10876.100.1.9.1.5ColumnraidAdapterSerialNumberread-onlycurrentThe serial number of the raid controller.
1.3.6.1.4.1.10876.100.1.9.1.6ColumnraidAdapterFWPackageBuildread-onlycurrentThe build number of the firmware package of the raid controller.
1.3.6.1.4.1.10876.100.1.9.1.7ColumnraidAdapterFWVersionread-onlycurrentThe firmware version of the raid controller.
1.3.6.1.4.1.10876.100.1.9.1.8ColumnraidAdapterBIOSVersionread-onlycurrentThe bios version of the raid controller.
1.3.6.1.4.1.10876.100.1.9.1.9ColumnraidAdapterVendorIdread-onlycurrentThe PCI vendor id of the raid controller.
1.3.6.1.4.1.10876.100.1.9.1.10ColumnraidAdapterDeviceIdread-onlycurrentThe PCI device id of the raid controller.
1.3.6.1.4.1.10876.100.1.9.1.11ColumnraidAdapterSubVendorIdread-onlycurrentThe PCI sub-vendor id of the raid controller.
1.3.6.1.4.1.10876.100.1.9.1.12ColumnraidAdapterSubDeviceIdread-onlycurrentThe PCI sub-device id of the raid controller.
1.3.6.1.4.1.10876.100.1.9.1.13ColumnraidIsBBUAbsentread-onlycurrentIs the BBU absent or present? Values: Absent, Present.
1.3.6.1.4.1.10876.100.1.9.1.14ColumnraidIsBBUAbsentIgnoredread-onlycurrentDoes the raid controller ignore the absent BBU? Values: YES, NO. If the value is No then the absent BBU will affect the all-in-one status of the raid controlle…
1.3.6.1.4.1.10876.100.1.9.1.15ColumnraidAdapterAllinoneStatusread-onlycurrentIndicates the status of the raid controller. Values: 0: OK 1: Warning 2: Critical
1.3.6.1.4.1.10876.100.1.9.1.16ColumnraidAdapterAllinoneMsgread-onlycurrentThe status message of the raid controller.
1.3.6.1.4.1.10876.100.1.10TableraidBBUTablenot-accessiblecurrentA table of raid BBU entries.
1.3.6.1.4.1.10876.100.1.10.1RowraidBBUEntrynot-accessiblecurrentAn entry in the raid BBU table. Entries cannot be created or deleted via SNMP operations.
1.3.6.1.4.1.10876.100.1.10.1.1ColumnraidBBUIndexread-onlycurrentRaid BBU index. The unique value which identifies this raid BBU.
1.3.6.1.4.1.10876.100.1.10.1.2ColumnraidAdapterGroup-BBUread-onlycurrentThe group of the raid controller. Values: LSI-MegaRAID LSI-Fusion-MPT
1.3.6.1.4.1.10876.100.1.10.1.3ColumnraidAdapterId-BBUread-onlycurrentThe id of the raid controller. The id is unique in one adapter group.
1.3.6.1.4.1.10876.100.1.10.1.8ColumnraidBBUStatusread-onlycurrentIndicates the status of the properties of the BBU. Values: Passed, Failed.
1.3.6.1.4.1.10876.100.1.10.1.9ColumnraidBBUAllinoneStatusread-onlycurrentIndicates the status of the BBU. Values: 0: OK 1: Warning 2: Critical
1.3.6.1.4.1.10876.100.1.10.1.10ColumnraidBBUAllinoneMsgread-onlycurrentThe status message of the BBU.
1.3.6.1.4.1.10876.100.1.11TableraidVDTablenot-accessiblecurrentA table of virtual drive entries.
1.3.6.1.4.1.10876.100.1.11.1RowraidVDEntrynot-accessiblecurrentAn entry in the virtual drive table. Entries cannot be created or deleted via SNMP operations.
1.3.6.1.4.1.10876.100.1.11.1.1ColumnraidVDIndexread-onlycurrentRaid virtual drive index. The unique value which identifies this raid virtual drive.
1.3.6.1.4.1.10876.100.1.11.1.2ColumnraidAdapterGroup-VDread-onlycurrentThe group of the raid controller. Values: LSI-MegaRAID LSI-Fusion-MPT
1.3.6.1.4.1.10876.100.1.11.1.3ColumnraidAdapterId-VDread-onlycurrentThe id of the raid controller. The id is unique in one adapter group.
1.3.6.1.4.1.10876.100.1.11.1.4ColumnraidDiskGroupIdread-onlycurrentThe disk group id of the virtual drive.
1.3.6.1.4.1.10876.100.1.11.1.5ColumnraidVDIdread-onlycurrentThe id of the virtual drive.
1.3.6.1.4.1.10876.100.1.11.1.6ColumnraidVDTargetIdread-onlycurrentThe target id of the virtual drive.
1.3.6.1.4.1.10876.100.1.11.1.7ColumnraidVDNameread-onlycurrentThe name of the virtual drive.
1.3.6.1.4.1.10876.100.1.11.1.8ColumnraidVDRaidLevelread-onlycurrentThe raid level of the virtual drive.
1.3.6.1.4.1.10876.100.1.11.1.9ColumnraidVDSizeread-onlycurrentThe size of the virtual drive.
1.3.6.1.4.1.10876.100.1.11.1.10ColumnraidVDMirrorDataSizeread-onlycurrentThe mirror data size of the virtual drive.
1.3.6.1.4.1.10876.100.1.11.1.11ColumnraidVDStripSizeread-onlycurrentThe stripe size of the virtual drive.
1.3.6.1.4.1.10876.100.1.11.1.12ColumnraidVDNumDrivesread-onlycurrentThe number of physical drives of the virtual drive.
1.3.6.1.4.1.10876.100.1.11.1.13ColumnraidVDSpanDepthread-onlycurrentThe span depth of the virtual drive.
1.3.6.1.4.1.10876.100.1.11.1.14ColumnraidVDDefaultCachePolicyread-onlycurrentThe default cache policy of the virtual drive.
1.3.6.1.4.1.10876.100.1.11.1.15ColumnraidVDCurrentCachePolicyread-onlycurrentThe current cache policy of the virtual drive.
1.3.6.1.4.1.10876.100.1.11.1.16ColumnraidVDDefaultAccessPolicyread-onlycurrentThe default access policy of the virtual drive.
1.3.6.1.4.1.10876.100.1.11.1.17ColumnraidVDCurrentAccessPolicyread-onlycurrentThe current access policy of the virtual drive.
1.3.6.1.4.1.10876.100.1.11.1.18ColumnraidVDDiskCachePolicyread-onlycurrentThe disk cache policy of the virtual drive.
1.3.6.1.4.1.10876.100.1.11.1.19ColumnraidVDEncryptionTyperead-onlycurrentThe encryption type of the virtual drive.
1.3.6.1.4.1.10876.100.1.11.1.20ColumnraidVDDefaultPSPolicyread-onlycurrentThe default power savings policy of the virtual drive.
1.3.6.1.4.1.10876.100.1.11.1.21ColumnraidVDCurrentPSPolicyread-onlycurrentThe default current savings policy of the virtual drive.
1.3.6.1.4.1.10876.100.1.11.1.22ColumnraidVDCanSpinUpIn1Minread-onlycurrentCan the physical drive spin up in 1 minute?
1.3.6.1.4.1.10876.100.1.11.1.23ColumnraidVDSupportT10Powerread-onlycurrentDoes the VD have drives that support T10 power conditions?
1.3.6.1.4.1.10876.100.1.11.1.24ColumnraidVDSupportsMaxPSread-onlycurrentDoes the VD's IO profile supports MAX power savings with cached writes?
1.3.6.1.4.1.10876.100.1.11.1.25ColumnraidVDBadBlocksExistread-onlycurrentDoes the virtual drive have bad blocks?
1.3.6.1.4.1.10876.100.1.11.1.26ColumnraidVDCachedread-onlycurrentIs the virtual drive cached?
1.3.6.1.4.1.10876.100.1.11.1.27ColumnraidVDStateread-onlycurrentThe state of the virtual drive. Values: Offline, Partially-degraded, Degraded, Optimal.
1.3.6.1.4.1.10876.100.1.11.1.28ColumnraidVDAllinoneStatusread-onlycurrentIndicates the status of the virtual drive. Values: 0: OK 1: Warning 2: Critical
1.3.6.1.4.1.10876.100.1.11.1.29ColumnraidVDAllinoneMsgread-onlycurrentThe status message of the virtual drive.
1.3.6.1.4.1.10876.100.1.12TableraidPDTablenot-accessiblecurrentA table of physical drive entries.
1.3.6.1.4.1.10876.100.1.12.1RowraidPDEntrynot-accessiblecurrentAn entry in the physical drive table. Entries cannot be created or deleted via SNMP operations.
1.3.6.1.4.1.10876.100.1.12.1.1ColumnraidPDIndexread-onlycurrentRaid physical drive index. The unique value which identifies this raid physical drive.
1.3.6.1.4.1.10876.100.1.12.1.2ColumnraidAdapterGroup-PDread-onlycurrentThe group of the raid controller. Values: LSI-MegaRAID LSI-Fusion-MPT
1.3.6.1.4.1.10876.100.1.12.1.3ColumnraidAdapterId-PDread-onlycurrentThe id of the raid controller. The id is unique in one adapter group.
1.3.6.1.4.1.10876.100.1.12.1.4ColumnraidDiskGroupId-PDread-onlycurrentThe disk group id of the virtual drive.
1.3.6.1.4.1.10876.100.1.12.1.5ColumnraidPDSlotNumberread-onlycurrentThe slot number of the physical drive.
1.3.6.1.4.1.10876.100.1.12.1.6ColumnraidPDFirmwareStateread-onlycurrentThe firmware state of the physical drive. Values: unconfigured-good, unconfigured-bad, hot-spare, offline, failed, rebuild, online, and copyback
1.3.6.1.4.1.10876.100.1.12.1.7ColumnraidPDMediaErrorCountread-onlycurrentThe media error count of the physical drive.
1.3.6.1.4.1.10876.100.1.12.1.8ColumnraidPDOtherErrorCountread-onlycurrentThe other error count of the physical drive.
1.3.6.1.4.1.10876.100.1.12.1.9ColumnraidPDPredFailCountread-onlycurrentThe predictive failure count of the physical drive.
1.3.6.1.4.1.10876.100.1.12.1.10ColumnraidPDLastPredFailEventSeqNoread-onlycurrentThe last predictive failure event sequence number of the physical drive.
1.3.6.1.4.1.10876.100.1.12.1.11ColumnraidPDRawSizeread-onlycurrentThe raw size of the physical drive.
1.3.6.1.4.1.10876.100.1.12.1.12ColumnraidPDDeviceFwLevelread-onlycurrentThe device firmware level of the physical drive.
1.3.6.1.4.1.10876.100.1.12.1.13ColumnraidPDInquiryDataread-onlycurrentThe inquiry data of the physical drive.
1.3.6.1.4.1.10876.100.1.12.1.14ColumnraidPDDeviceSpeedread-onlycurrentThe device speed of the physical drive.
1.3.6.1.4.1.10876.100.1.12.1.15ColumnraidPDLinkSpeedread-onlycurrentThe link speed of the physical drive.
1.3.6.1.4.1.10876.100.1.12.1.16ColumnraidPDMediaTyperead-onlycurrentThe media type of the physical drive.
1.3.6.1.4.1.10876.100.1.12.1.17ColumnraidPDWriteCacheread-onlycurrentThe write cache of the physical drive.
1.3.6.1.4.1.10876.100.1.12.1.18ColumnraidPDNCQSettingread-onlycurrentThe NCQ setting of the physical drive.
1.3.6.1.4.1.10876.100.1.12.1.19ColumnraidPDPort0Linkspeedread-onlycurrentThe link speed of port 0 of the physical drive.
1.3.6.1.4.1.10876.100.1.12.1.20ColumnraidPDPort0Statusread-onlycurrentThe status of port 0 of the physical drive.
1.3.6.1.4.1.10876.100.1.12.1.21ColumnraidPDPort1Linkspeedread-onlycurrentThe link speed of port 1 of the physical drive.
1.3.6.1.4.1.10876.100.1.12.1.22ColumnraidPDPort1Statusread-onlycurrentThe status of port 1 of the physical drive.
1.3.6.1.4.1.10876.100.1.12.1.23ColumnraidPDEnclosureDeviceIDread-onlycurrentThe enclosure id of the physical drive.
1.3.6.1.4.1.10876.100.1.12.1.24ColumnraidPDOpProgressread-onlycurrentThe operation progress of the physical drive.
1.3.6.1.4.1.10876.100.1.12.1.25ColumnraidPDSpanread-onlycurrentThe span of the physical drive.
1.3.6.1.4.1.10876.100.1.12.1.26ColumnraidPDAllinoneStatusread-onlycurrentIndicates the status of the physical drive. Values: 0: OK 1: Warning 2: Critical
1.3.6.1.4.1.10876.100.1.12.1.27ColumnraidPDAllinoneMsgread-onlycurrentThe status message of the physical drive.
1.3.6.1.4.1.10876.100.1.12.1.28ColumnraidPDModelread-onlycurrentThe model of the physical drive.
1.3.6.1.4.1.10876.100.1.12.1.29ColumnraidPDSerialNumberread-onlycurrentThe serial number of the physical drive.
1.3.6.1.4.1.10876.100.1.12.1.30ColumnraidPDFirmwareRevisionread-onlycurrentThe firmware revision of the physical drive.
1.3.6.1.4.1.10876.100.3NodesmSD5TrapMIB
1.3.6.1.4.1.10876.100.3.101NodetrapFanNormalFan Speed has returned to Normal
1.3.6.1.4.1.10876.100.3.102NodetrapFanWarningFan Speed is Warning
1.3.6.1.4.1.10876.100.3.103NodetrapFanCriticalFan Speed is Critical
1.3.6.1.4.1.10876.100.3.201NodetrapVoltageNormalVoltage has returned to Normal
1.3.6.1.4.1.10876.100.3.202NodetrapVoltageWarningVoltage is Warning
1.3.6.1.4.1.10876.100.3.203NodetrapVoltageCriticalVoltage is Critical
1.3.6.1.4.1.10876.100.3.301NodetrapTemperatureNormalTemperature has returned to Normal
1.3.6.1.4.1.10876.100.3.302NodetrapTemperatureWarningTemperature is Warning
1.3.6.1.4.1.10876.100.3.303NodetrapTemperatureCriticalTemperature is Critical
1.3.6.1.4.1.10876.100.3.401NodetrapChassisIntrusionClearedChassis Intrusion has cleared
1.3.6.1.4.1.10876.100.3.403NodetrapChassisIntrusionChassis Intrusion has triggered
1.3.6.1.4.1.10876.100.3.601NodetrapStorageSMARTCheckNormalStorage SMART Check has returned to Normal
1.3.6.1.4.1.10876.100.3.602NodetrapStorageSMARTCheckWarningStorage SMART Check is Warning
1.3.6.1.4.1.10876.100.3.603NodetrapStorageSMARTCheckCriticalStorage SMART Check is Critical
1.3.6.1.4.1.10876.100.3.701NodetrapPowerSupplyNormalPower Supply has returned to Normal
1.3.6.1.4.1.10876.100.3.702NodetrapPowerSupplyWarningPower Supply is Warning
1.3.6.1.4.1.10876.100.3.703NodetrapPowerSupplyCriticalPower Supply is Critical
1.3.6.1.4.1.10876.100.3.801NodetrapMemoryCeccNormalMemory CECC has returned to Normal
1.3.6.1.4.1.10876.100.3.802NodetrapMemoryCeccWarningMemory CECC is Warning
1.3.6.1.4.1.10876.100.3.803NodetrapMemoryCeccCriticalMemory CECC is Critical
1.3.6.1.4.1.10876.100.3.901NodetrapMemoryUeccNormalMemory UECC has returned to Normal
1.3.6.1.4.1.10876.100.3.902NodetrapMemoryUeccWarningMemory UECC is Warning
1.3.6.1.4.1.10876.100.3.903NodetrapMemoryUeccCriticalMemory UECC Critical
1.3.6.1.4.1.10876.100.3.1001NodetrapGenericNormalMonitored item has returned to Normal
1.3.6.1.4.1.10876.100.3.1002NodetrapGenericWarningMonitored item is Warning
1.3.6.1.4.1.10876.100.3.1003NodetrapGenericCriticalMonitored item Critical
1.3.6.1.4.1.10876.100.3.1101NodetrapBbpStatusNormalBBP has returned to Normal
1.3.6.1.4.1.10876.100.3.1102NodetrapBbpStatusWarningBBP is Warning
1.3.6.1.4.1.10876.100.3.1103NodetrapBbpStatusCriticalBBP is Critical
1.3.6.1.4.1.10876.100.3.1201NodetrapCpuFaultNormalProcessor Fault has returned to Normal
1.3.6.1.4.1.10876.100.3.1202NodetrapCpuFaultWarningProcessor Fault is Warning
1.3.6.1.4.1.10876.100.3.1203NodetrapCpuFaultCriticalProcessor Fault is Critical
1.3.6.1.4.1.10876.100.3.1301NodetrapStorageAdapterStatusNormalStorage Adapter has returned to Normal
1.3.6.1.4.1.10876.100.3.1302NodetrapStorageAdapterStatusWarningStorage Adapter is Warning
1.3.6.1.4.1.10876.100.3.1303NodetrapStorageAdapterStatusCriticalStorage Adapter is Critical
1.3.6.1.4.1.10876.100.3.1401NodetrapBatteryStatusNormalBattery has returned to Normal
1.3.6.1.4.1.10876.100.3.1402NodetrapBatteryStatusWarningBattery is Warning
1.3.6.1.4.1.10876.100.3.1403NodetrapBatteryStatusCriticalBattery is Critical