SUPERMICRO-SD5-MIB
223 objects
MIB module for sd5 information
Imported Objects
| SNMPv2-SMI | Integer32 MODULE-IDENTITY OBJECT-TYPE |
| SNMPv2-TC | DisplayString |
| SUPERMICRO-SMI | smSSMInfo |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.10876.100.1 | IdentitysmSuperDoctor5MIB | MIB module for sd5 information | ||
| 1.3.6.1.4.1.10876.100.1.1 | Tablesd5Table | not-accessible | current | A table of sd5 entries. |
| 1.3.6.1.4.1.10876.100.1.1.1 | Rowsd5Entry | not-accessible | current | An entry in the sd5 table. Entries cannot be created or deleted via SNMP operations. |
| 1.3.6.1.4.1.10876.100.1.1.1.1 | Columnsd5Idx | read-only | current | The unique value identifies this sd5. |
| 1.3.6.1.4.1.10876.100.1.1.1.2 | Columnsd5Version | read-only | current | The version of the sd5. |
| 1.3.6.1.4.1.10876.100.1.1.1.3 | Columnsd5MIBVersion | read-only | current | The MIB version of the sd5. |
| 1.3.6.1.4.1.10876.100.1.2 | TablecpuTable | not-accessible | current | A table of processor entries. |
| 1.3.6.1.4.1.10876.100.1.2.1 | RowcpuEntry | not-accessible | current | An entry in the processor table. Entries cannot be created or deleted via SNMP operations. |
| 1.3.6.1.4.1.10876.100.1.2.1.1 | ColumncpuIndex | read-only | current | The unique value which identifies this processor. |
| 1.3.6.1.4.1.10876.100.1.2.1.2 | ColumncpuName | read-only | current | The name of the processor. |
| 1.3.6.1.4.1.10876.100.1.2.1.3 | ColumncpuDescription | read-only | current | The description of the processor. |
| 1.3.6.1.4.1.10876.100.1.2.1.4 | ColumncpuManufacturer | read-only | current | The manufacturer of the processor. |
| 1.3.6.1.4.1.10876.100.1.2.1.5 | ColumncpuDeviceStatus | read-only | current | The status of the processor. The status depends on the cpu failure check via BIOS. 0: OK 2: Critical |
| 1.3.6.1.4.1.10876.100.1.2.1.6 | ColumncpuMaxSpeed | read-only | current | The maximum speed (MHz) of the processor. |
| 1.3.6.1.4.1.10876.100.1.2.1.7 | ColumncpuCurrentSpeed | read-only | current | The current speed (MHz) of the processor. |
| 1.3.6.1.4.1.10876.100.1.2.1.9 | ColumncpuLoadingPercentage | read-only | current | The loading percentage of the processor. |
| 1.3.6.1.4.1.10876.100.1.2.1.10 | ColumncpuCoreEnabled | read-only | current | The core enabled count of the processor. |
| 1.3.6.1.4.1.10876.100.1.2.1.11 | ColumncpuCoreCount | read-only | current | The core count of the processor. |
| 1.3.6.1.4.1.10876.100.1.2.1.12 | ColumncpuThreadCount | read-only | current | The thread count of the processor. |
| 1.3.6.1.4.1.10876.100.1.2.1.14 | ColumncpuSocketDesignation | read-only | current | The socket designation of the processor. |
| 1.3.6.1.4.1.10876.100.1.2.1.18 | ColumncpuDeviceVersion | read-only | current | The device version of the processor. |
| 1.3.6.1.4.1.10876.100.1.2.1.20 | ColumncpuDeviceID | read-only | current | The device ID of the processor. |
| 1.3.6.1.4.1.10876.100.1.2.1.21 | ColumncpuID | read-only | current | The ID of the processor. |
| 1.3.6.1.4.1.10876.100.1.3 | TablememTable | not-accessible | current | A table of physical memory entries. |
| 1.3.6.1.4.1.10876.100.1.3.1 | RowmemEntry | not-accessible | current | An entry in the physical memory table. Entries cannot be created or deleted via SNMP operations. |
| 1.3.6.1.4.1.10876.100.1.3.1.1 | ColumnmemTag | read-only | current | The tag of the physical memory. The unique value identifies this physical memory. |
| 1.3.6.1.4.1.10876.100.1.3.1.2 | ColumnmemDescription | read-only | current | The description of the physical memory. |
| 1.3.6.1.4.1.10876.100.1.3.1.3 | ColumnmemDeviceStatus | read-only | current | Indicates the status of the physical memory. The status depends on the ECC check result on the physical memory. 0: OK 2: Critical |
| 1.3.6.1.4.1.10876.100.1.3.1.4 | ColumnmemLabeledBank | read-only | current | The labeled bank of the physical memory. |
| 1.3.6.1.4.1.10876.100.1.3.1.5 | ColumnmemDeviceLocator | read-only | current | The device locator of the physical memory. |
| 1.3.6.1.4.1.10876.100.1.3.1.7 | ColumnmemModel | read-only | current | The model name of the physical memory. |
| 1.3.6.1.4.1.10876.100.1.3.1.8 | ColumnmemManufacturer | read-only | current | The manufacturer's name of the physical memory. |
| 1.3.6.1.4.1.10876.100.1.3.1.9 | ColumnmemPartNumber | read-only | current | The part number of the physical memory. |
| 1.3.6.1.4.1.10876.100.1.3.1.10 | ColumnmemSerialNumber | read-only | current | The serial number of the physical memory. |
| 1.3.6.1.4.1.10876.100.1.3.1.11 | ColumnmemCapacity | read-only | current | The capacity of the physical memory. (Unit: MB) |
| 1.3.6.1.4.1.10876.100.1.3.1.12 | ColumnmemDataWidth | read-only | current | The data width of the physical memory. (Unit: bit) |
| 1.3.6.1.4.1.10876.100.1.3.1.13 | ColumnmemTotalWidth | read-only | current | The total width of the physical memory. (Unit: bit) |
| 1.3.6.1.4.1.10876.100.1.3.1.15 | ColumnmemErrorCount | read-only | current | The error count of the physical memory. It's the summary of the ECC error count and UECC error count. |
| 1.3.6.1.4.1.10876.100.1.3.1.16 | ColumnmemECCErrorCount | read-only | current | The ECC error count of the physical memory. |
| 1.3.6.1.4.1.10876.100.1.3.1.17 | ColumnmemUECCErrorCount | read-only | current | The UECC error count of the physical memory. |
| 1.3.6.1.4.1.10876.100.1.4 | TablediskTable | not-accessible | current | A table of physical disk entries. |
| 1.3.6.1.4.1.10876.100.1.4.1 | RowdiskEntry | not-accessible | current | An entry in the physical disk table. Entries cannot be created or deleted via SNMP operations. |
| 1.3.6.1.4.1.10876.100.1.4.1.1 | ColumndiskSerialNumber | read-only | current | The serial number of the disk. |
| 1.3.6.1.4.1.10876.100.1.4.1.2 | ColumndiskName | read-only | current | The name of the disk. The unique value identifies this disk. |
| 1.3.6.1.4.1.10876.100.1.4.1.3 | ColumndiskVendor | read-only | current | The vendor name of the disk. |
| 1.3.6.1.4.1.10876.100.1.4.1.4 | ColumndiskSmartStatus | read-only | current | Indicates the status of the disk. The status depends on the SMART check result on the disk. 0: OK 2: Critical |
| 1.3.6.1.4.1.10876.100.1.4.1.5 | ColumndiskModel | read-only | current | The model of the disk. |
| 1.3.6.1.4.1.10876.100.1.4.1.6 | ColumndiskSize | read-only | current | The size of the disk. (Unit: MB) |
| 1.3.6.1.4.1.10876.100.1.4.1.8 | ColumndiskMediaType | read-only | current | The media type of the disk includes External hard disk media Removable media other than floppy Fixed hard disk media and Unknown format |
| 1.3.6.1.4.1.10876.100.1.4.1.9 | ColumndiskInterfaceType | read-only | current | The disk interface types includes IDE, HDC, USB, and SCSI. |
| 1.3.6.1.4.1.10876.100.1.4.1.10 | ColumndiskController | read-only | current | The controller name of the disk. |
| 1.3.6.1.4.1.10876.100.1.4.1.11 | ColumndiskSlotID | read-only | current | The Slot ID of the disk. |
| 1.3.6.1.4.1.10876.100.1.5 | TablesysBIOSTable | not-accessible | current | A table of System BIOS entries. |
| 1.3.6.1.4.1.10876.100.1.5.1 | RowsysBIOSEntry | not-accessible | current | An entry in the System BIOS table. Entries cannot be created or deleted via SNMP operations. |
| 1.3.6.1.4.1.10876.100.1.5.1.1 | ColumnsysBIOSIndex | read-only | current | The unique value identifies this BIOS. |
| 1.3.6.1.4.1.10876.100.1.5.1.7 | ColumnsysBIOSReleaseDate | read-only | current | The release date of BIOS. |
| 1.3.6.1.4.1.10876.100.1.5.1.8 | ColumnsysBIOSVersion | read-only | current | The version of BIOS. |
| 1.3.6.1.4.1.10876.100.1.5.1.11 | ColumnsysBIOSManufacturer | read-only | current | The manufacturer's name of BIOS. |
| 1.3.6.1.4.1.10876.100.1.6 | TablembTable | not-accessible | current | A table of baseboard entries. |
| 1.3.6.1.4.1.10876.100.1.6.1 | RowmbEntry | not-accessible | current | An entry in the baseboard table. Entries cannot be created or deleted via SNMP operations. |
| 1.3.6.1.4.1.10876.100.1.6.1.1 | ColumnmbIndex | read-only | current | The unique value identifies this baseboard. |
| 1.3.6.1.4.1.10876.100.1.6.1.10 | ColumnmbManufacturer | read-only | current | The manufacturer's name of the baseboard. |
| 1.3.6.1.4.1.10876.100.1.6.1.11 | ColumnmbProductName | read-only | current | The product name of the baseboard. |
| 1.3.6.1.4.1.10876.100.1.6.1.12 | ColumnmbVersionName | read-only | current | The version of the baseboard. |
| 1.3.6.1.4.1.10876.100.1.6.1.15 | ColumnmbAssetTag | read-only | current | The asset tag of the baseboard. |
| 1.3.6.1.4.1.10876.100.1.6.1.16 | ColumnmbSerialNumber | read-only | current | The serial number of the baseboard. |
| 1.3.6.1.4.1.10876.100.1.7 | TableosTable | not-accessible | current | A table of operation system entries. |
| 1.3.6.1.4.1.10876.100.1.7.1 | RowosEntry | not-accessible | current | An entry in the operation system table. Entries cannot be created or deleted via SNMP operations. |
| 1.3.6.1.4.1.10876.100.1.7.1.1 | ColumnosIndex | read-only | current | The unique value identifies this Operation System. |
| 1.3.6.1.4.1.10876.100.1.7.1.6 | ColumnosName | read-only | current | The name of the Operation System. |
| 1.3.6.1.4.1.10876.100.1.7.1.7 | ColumnosVersion | read-only | current | The version of the operation system. |
| 1.3.6.1.4.1.10876.100.1.7.1.8 | ColumnosManufacturer | read-only | current | The manufacturer's name of the Operation System. |
| 1.3.6.1.4.1.10876.100.1.7.1.9 | ColumnosSerialNumber | read-only | current | The serial number of the operation system. |
| 1.3.6.1.4.1.10876.100.1.7.1.10 | ColumnosCSDVersion | read-only | current | The CSD version of the operation system. |
| 1.3.6.1.4.1.10876.100.1.8 | NodedmiLogTable | |||
| 1.3.6.1.4.1.10876.100.1.8.1 | TablececcLogTable | not-accessible | current | A table of operation system entries. |
| 1.3.6.1.4.1.10876.100.1.8.1.1 | RowceccLogEntry | not-accessible | current | An entry in the operation system table. Entries cannot be created or deleted via SNMP operations. |
| 1.3.6.1.4.1.10876.100.1.8.1.1.1 | ColumnceccLogDatetime | read-only | current | The CSD version of the operation system. |
| 1.3.6.1.4.1.10876.100.1.8.1.1.2 | ColumnceccLogInfo | read-only | current | The CSD version of the operation system. |
| 1.3.6.1.4.1.10876.100.1.8.1.1.10 | ColumnceccLogIndex | read-only | current | The CSD version of the operation system. |
| 1.3.6.1.4.1.10876.100.1.8.2 | TableueccLogTable | not-accessible | current | A table of operation system entries. |
| 1.3.6.1.4.1.10876.100.1.8.2.1 | RowueccLogEntry | not-accessible | current | An entry in the operation system table. Entries cannot be created or deleted via SNMP operations. |
| 1.3.6.1.4.1.10876.100.1.8.2.1.1 | ColumnueccLogDatetime | read-only | current | The CSD version of the operation system. |
| 1.3.6.1.4.1.10876.100.1.8.2.1.2 | ColumnueccLogInfo | read-only | current | The CSD version of the operation system. |
| 1.3.6.1.4.1.10876.100.1.8.2.1.10 | ColumnueccLogIndex | read-only | current | The CSD version of the operation system. |
| 1.3.6.1.4.1.10876.100.1.8.8 | TablepostLogTable | not-accessible | current | A table of operation system entries. |
| 1.3.6.1.4.1.10876.100.1.8.8.1 | RowpostLogEntry | not-accessible | current | An entry in the operation system table. Entries cannot be created or deleted via SNMP operations. |
| 1.3.6.1.4.1.10876.100.1.8.8.1.1 | ColumnpostLogDatetime | read-only | current | The CSD version of the operation system. |
| 1.3.6.1.4.1.10876.100.1.8.8.1.2 | ColumnpostLogInfo | read-only | current | The CSD version of the operation system. |
| 1.3.6.1.4.1.10876.100.1.8.8.1.10 | ColumnpostLogIndex | read-only | current | The CSD version of the operation system. |
| 1.3.6.1.4.1.10876.100.1.8.11 | TablecpuLogTable | not-accessible | current | A table of operation system entries. |
| 1.3.6.1.4.1.10876.100.1.8.11.1 | RowcpuLogEntry | not-accessible | current | An entry in the operation system table. Entries cannot be created or deleted via SNMP operations. |
| 1.3.6.1.4.1.10876.100.1.8.11.1.1 | ColumncpuLogDatetime | read-only | current | The CSD version of the operation system. |
| 1.3.6.1.4.1.10876.100.1.8.11.1.2 | ColumncpuLogInfo | read-only | current | The CSD version of the operation system. |
| 1.3.6.1.4.1.10876.100.1.8.11.1.10 | ColumncpuLogIndex | read-only | current | The CSD version of the operation system. |
| 1.3.6.1.4.1.10876.100.1.9 | TableraidAdapterTable | not-accessible | current | A table of raid controller entries. |
| 1.3.6.1.4.1.10876.100.1.9.1 | RowraidAdapterEntry | not-accessible | current | An entry in the raid controller table. Entries cannot be created or deleted via SNMP operations. |
| 1.3.6.1.4.1.10876.100.1.9.1.1 | ColumnraidAdapterIndex | read-only | current | Raid controller index. The unique value which identifies this raid controller. |
| 1.3.6.1.4.1.10876.100.1.9.1.2 | ColumnraidAdapterGroup | read-only | current | The group of the raid controller. Values: LSI-MegaRAID LSI-Fusion-MPT |
| 1.3.6.1.4.1.10876.100.1.9.1.3 | ColumnraidAdapterId | read-only | current | The id of the raid controller. The id is unique in one adapter group. |
| 1.3.6.1.4.1.10876.100.1.9.1.4 | ColumnraidAdapterProductName | read-only | current | The product name of the raid controller. |
| 1.3.6.1.4.1.10876.100.1.9.1.5 | ColumnraidAdapterSerialNumber | read-only | current | The serial number of the raid controller. |
| 1.3.6.1.4.1.10876.100.1.9.1.6 | ColumnraidAdapterFWPackageBuild | read-only | current | The build number of the firmware package of the raid controller. |
| 1.3.6.1.4.1.10876.100.1.9.1.7 | ColumnraidAdapterFWVersion | read-only | current | The firmware version of the raid controller. |
| 1.3.6.1.4.1.10876.100.1.9.1.8 | ColumnraidAdapterBIOSVersion | read-only | current | The bios version of the raid controller. |
| 1.3.6.1.4.1.10876.100.1.9.1.9 | ColumnraidAdapterVendorId | read-only | current | The PCI vendor id of the raid controller. |
| 1.3.6.1.4.1.10876.100.1.9.1.10 | ColumnraidAdapterDeviceId | read-only | current | The PCI device id of the raid controller. |
| 1.3.6.1.4.1.10876.100.1.9.1.11 | ColumnraidAdapterSubVendorId | read-only | current | The PCI sub-vendor id of the raid controller. |
| 1.3.6.1.4.1.10876.100.1.9.1.12 | ColumnraidAdapterSubDeviceId | read-only | current | The PCI sub-device id of the raid controller. |
| 1.3.6.1.4.1.10876.100.1.9.1.13 | ColumnraidIsBBUAbsent | read-only | current | Is the BBU absent or present? Values: Absent, Present. |
| 1.3.6.1.4.1.10876.100.1.9.1.14 | ColumnraidIsBBUAbsentIgnored | read-only | current | Does the raid controller ignore the absent BBU? Values: YES, NO. If the value is No then the absent BBU will affect the all-in-one status of the raid controlle… |
| 1.3.6.1.4.1.10876.100.1.9.1.15 | ColumnraidAdapterAllinoneStatus | read-only | current | Indicates the status of the raid controller. Values: 0: OK 1: Warning 2: Critical |
| 1.3.6.1.4.1.10876.100.1.9.1.16 | ColumnraidAdapterAllinoneMsg | read-only | current | The status message of the raid controller. |
| 1.3.6.1.4.1.10876.100.1.10 | TableraidBBUTable | not-accessible | current | A table of raid BBU entries. |
| 1.3.6.1.4.1.10876.100.1.10.1 | RowraidBBUEntry | not-accessible | current | An entry in the raid BBU table. Entries cannot be created or deleted via SNMP operations. |
| 1.3.6.1.4.1.10876.100.1.10.1.1 | ColumnraidBBUIndex | read-only | current | Raid BBU index. The unique value which identifies this raid BBU. |
| 1.3.6.1.4.1.10876.100.1.10.1.2 | ColumnraidAdapterGroup-BBU | read-only | current | The group of the raid controller. Values: LSI-MegaRAID LSI-Fusion-MPT |
| 1.3.6.1.4.1.10876.100.1.10.1.3 | ColumnraidAdapterId-BBU | read-only | current | The id of the raid controller. The id is unique in one adapter group. |
| 1.3.6.1.4.1.10876.100.1.10.1.8 | ColumnraidBBUStatus | read-only | current | Indicates the status of the properties of the BBU. Values: Passed, Failed. |
| 1.3.6.1.4.1.10876.100.1.10.1.9 | ColumnraidBBUAllinoneStatus | read-only | current | Indicates the status of the BBU. Values: 0: OK 1: Warning 2: Critical |
| 1.3.6.1.4.1.10876.100.1.10.1.10 | ColumnraidBBUAllinoneMsg | read-only | current | The status message of the BBU. |
| 1.3.6.1.4.1.10876.100.1.11 | TableraidVDTable | not-accessible | current | A table of virtual drive entries. |
| 1.3.6.1.4.1.10876.100.1.11.1 | RowraidVDEntry | not-accessible | current | An entry in the virtual drive table. Entries cannot be created or deleted via SNMP operations. |
| 1.3.6.1.4.1.10876.100.1.11.1.1 | ColumnraidVDIndex | read-only | current | Raid virtual drive index. The unique value which identifies this raid virtual drive. |
| 1.3.6.1.4.1.10876.100.1.11.1.2 | ColumnraidAdapterGroup-VD | read-only | current | The group of the raid controller. Values: LSI-MegaRAID LSI-Fusion-MPT |
| 1.3.6.1.4.1.10876.100.1.11.1.3 | ColumnraidAdapterId-VD | read-only | current | The id of the raid controller. The id is unique in one adapter group. |
| 1.3.6.1.4.1.10876.100.1.11.1.4 | ColumnraidDiskGroupId | read-only | current | The disk group id of the virtual drive. |
| 1.3.6.1.4.1.10876.100.1.11.1.5 | ColumnraidVDId | read-only | current | The id of the virtual drive. |
| 1.3.6.1.4.1.10876.100.1.11.1.6 | ColumnraidVDTargetId | read-only | current | The target id of the virtual drive. |
| 1.3.6.1.4.1.10876.100.1.11.1.7 | ColumnraidVDName | read-only | current | The name of the virtual drive. |
| 1.3.6.1.4.1.10876.100.1.11.1.8 | ColumnraidVDRaidLevel | read-only | current | The raid level of the virtual drive. |
| 1.3.6.1.4.1.10876.100.1.11.1.9 | ColumnraidVDSize | read-only | current | The size of the virtual drive. |
| 1.3.6.1.4.1.10876.100.1.11.1.10 | ColumnraidVDMirrorDataSize | read-only | current | The mirror data size of the virtual drive. |
| 1.3.6.1.4.1.10876.100.1.11.1.11 | ColumnraidVDStripSize | read-only | current | The stripe size of the virtual drive. |
| 1.3.6.1.4.1.10876.100.1.11.1.12 | ColumnraidVDNumDrives | read-only | current | The number of physical drives of the virtual drive. |
| 1.3.6.1.4.1.10876.100.1.11.1.13 | ColumnraidVDSpanDepth | read-only | current | The span depth of the virtual drive. |
| 1.3.6.1.4.1.10876.100.1.11.1.14 | ColumnraidVDDefaultCachePolicy | read-only | current | The default cache policy of the virtual drive. |
| 1.3.6.1.4.1.10876.100.1.11.1.15 | ColumnraidVDCurrentCachePolicy | read-only | current | The current cache policy of the virtual drive. |
| 1.3.6.1.4.1.10876.100.1.11.1.16 | ColumnraidVDDefaultAccessPolicy | read-only | current | The default access policy of the virtual drive. |
| 1.3.6.1.4.1.10876.100.1.11.1.17 | ColumnraidVDCurrentAccessPolicy | read-only | current | The current access policy of the virtual drive. |
| 1.3.6.1.4.1.10876.100.1.11.1.18 | ColumnraidVDDiskCachePolicy | read-only | current | The disk cache policy of the virtual drive. |
| 1.3.6.1.4.1.10876.100.1.11.1.19 | ColumnraidVDEncryptionType | read-only | current | The encryption type of the virtual drive. |
| 1.3.6.1.4.1.10876.100.1.11.1.20 | ColumnraidVDDefaultPSPolicy | read-only | current | The default power savings policy of the virtual drive. |
| 1.3.6.1.4.1.10876.100.1.11.1.21 | ColumnraidVDCurrentPSPolicy | read-only | current | The default current savings policy of the virtual drive. |
| 1.3.6.1.4.1.10876.100.1.11.1.22 | ColumnraidVDCanSpinUpIn1Min | read-only | current | Can the physical drive spin up in 1 minute? |
| 1.3.6.1.4.1.10876.100.1.11.1.23 | ColumnraidVDSupportT10Power | read-only | current | Does the VD have drives that support T10 power conditions? |
| 1.3.6.1.4.1.10876.100.1.11.1.24 | ColumnraidVDSupportsMaxPS | read-only | current | Does the VD's IO profile supports MAX power savings with cached writes? |
| 1.3.6.1.4.1.10876.100.1.11.1.25 | ColumnraidVDBadBlocksExist | read-only | current | Does the virtual drive have bad blocks? |
| 1.3.6.1.4.1.10876.100.1.11.1.26 | ColumnraidVDCached | read-only | current | Is the virtual drive cached? |
| 1.3.6.1.4.1.10876.100.1.11.1.27 | ColumnraidVDState | read-only | current | The state of the virtual drive. Values: Offline, Partially-degraded, Degraded, Optimal. |
| 1.3.6.1.4.1.10876.100.1.11.1.28 | ColumnraidVDAllinoneStatus | read-only | current | Indicates the status of the virtual drive. Values: 0: OK 1: Warning 2: Critical |
| 1.3.6.1.4.1.10876.100.1.11.1.29 | ColumnraidVDAllinoneMsg | read-only | current | The status message of the virtual drive. |
| 1.3.6.1.4.1.10876.100.1.12 | TableraidPDTable | not-accessible | current | A table of physical drive entries. |
| 1.3.6.1.4.1.10876.100.1.12.1 | RowraidPDEntry | not-accessible | current | An entry in the physical drive table. Entries cannot be created or deleted via SNMP operations. |
| 1.3.6.1.4.1.10876.100.1.12.1.1 | ColumnraidPDIndex | read-only | current | Raid physical drive index. The unique value which identifies this raid physical drive. |
| 1.3.6.1.4.1.10876.100.1.12.1.2 | ColumnraidAdapterGroup-PD | read-only | current | The group of the raid controller. Values: LSI-MegaRAID LSI-Fusion-MPT |
| 1.3.6.1.4.1.10876.100.1.12.1.3 | ColumnraidAdapterId-PD | read-only | current | The id of the raid controller. The id is unique in one adapter group. |
| 1.3.6.1.4.1.10876.100.1.12.1.4 | ColumnraidDiskGroupId-PD | read-only | current | The disk group id of the virtual drive. |
| 1.3.6.1.4.1.10876.100.1.12.1.5 | ColumnraidPDSlotNumber | read-only | current | The slot number of the physical drive. |
| 1.3.6.1.4.1.10876.100.1.12.1.6 | ColumnraidPDFirmwareState | read-only | current | The firmware state of the physical drive. Values: unconfigured-good, unconfigured-bad, hot-spare, offline, failed, rebuild, online, and copyback |
| 1.3.6.1.4.1.10876.100.1.12.1.7 | ColumnraidPDMediaErrorCount | read-only | current | The media error count of the physical drive. |
| 1.3.6.1.4.1.10876.100.1.12.1.8 | ColumnraidPDOtherErrorCount | read-only | current | The other error count of the physical drive. |
| 1.3.6.1.4.1.10876.100.1.12.1.9 | ColumnraidPDPredFailCount | read-only | current | The predictive failure count of the physical drive. |
| 1.3.6.1.4.1.10876.100.1.12.1.10 | ColumnraidPDLastPredFailEventSeqNo | read-only | current | The last predictive failure event sequence number of the physical drive. |
| 1.3.6.1.4.1.10876.100.1.12.1.11 | ColumnraidPDRawSize | read-only | current | The raw size of the physical drive. |
| 1.3.6.1.4.1.10876.100.1.12.1.12 | ColumnraidPDDeviceFwLevel | read-only | current | The device firmware level of the physical drive. |
| 1.3.6.1.4.1.10876.100.1.12.1.13 | ColumnraidPDInquiryData | read-only | current | The inquiry data of the physical drive. |
| 1.3.6.1.4.1.10876.100.1.12.1.14 | ColumnraidPDDeviceSpeed | read-only | current | The device speed of the physical drive. |
| 1.3.6.1.4.1.10876.100.1.12.1.15 | ColumnraidPDLinkSpeed | read-only | current | The link speed of the physical drive. |
| 1.3.6.1.4.1.10876.100.1.12.1.16 | ColumnraidPDMediaType | read-only | current | The media type of the physical drive. |
| 1.3.6.1.4.1.10876.100.1.12.1.17 | ColumnraidPDWriteCache | read-only | current | The write cache of the physical drive. |
| 1.3.6.1.4.1.10876.100.1.12.1.18 | ColumnraidPDNCQSetting | read-only | current | The NCQ setting of the physical drive. |
| 1.3.6.1.4.1.10876.100.1.12.1.19 | ColumnraidPDPort0Linkspeed | read-only | current | The link speed of port 0 of the physical drive. |
| 1.3.6.1.4.1.10876.100.1.12.1.20 | ColumnraidPDPort0Status | read-only | current | The status of port 0 of the physical drive. |
| 1.3.6.1.4.1.10876.100.1.12.1.21 | ColumnraidPDPort1Linkspeed | read-only | current | The link speed of port 1 of the physical drive. |
| 1.3.6.1.4.1.10876.100.1.12.1.22 | ColumnraidPDPort1Status | read-only | current | The status of port 1 of the physical drive. |
| 1.3.6.1.4.1.10876.100.1.12.1.23 | ColumnraidPDEnclosureDeviceID | read-only | current | The enclosure id of the physical drive. |
| 1.3.6.1.4.1.10876.100.1.12.1.24 | ColumnraidPDOpProgress | read-only | current | The operation progress of the physical drive. |
| 1.3.6.1.4.1.10876.100.1.12.1.25 | ColumnraidPDSpan | read-only | current | The span of the physical drive. |
| 1.3.6.1.4.1.10876.100.1.12.1.26 | ColumnraidPDAllinoneStatus | read-only | current | Indicates the status of the physical drive. Values: 0: OK 1: Warning 2: Critical |
| 1.3.6.1.4.1.10876.100.1.12.1.27 | ColumnraidPDAllinoneMsg | read-only | current | The status message of the physical drive. |
| 1.3.6.1.4.1.10876.100.1.12.1.28 | ColumnraidPDModel | read-only | current | The model of the physical drive. |
| 1.3.6.1.4.1.10876.100.1.12.1.29 | ColumnraidPDSerialNumber | read-only | current | The serial number of the physical drive. |
| 1.3.6.1.4.1.10876.100.1.12.1.30 | ColumnraidPDFirmwareRevision | read-only | current | The firmware revision of the physical drive. |
| 1.3.6.1.4.1.10876.100.3 | NodesmSD5TrapMIB | |||
| 1.3.6.1.4.1.10876.100.3.101 | NodetrapFanNormal | Fan Speed has returned to Normal | ||
| 1.3.6.1.4.1.10876.100.3.102 | NodetrapFanWarning | Fan Speed is Warning | ||
| 1.3.6.1.4.1.10876.100.3.103 | NodetrapFanCritical | Fan Speed is Critical | ||
| 1.3.6.1.4.1.10876.100.3.201 | NodetrapVoltageNormal | Voltage has returned to Normal | ||
| 1.3.6.1.4.1.10876.100.3.202 | NodetrapVoltageWarning | Voltage is Warning | ||
| 1.3.6.1.4.1.10876.100.3.203 | NodetrapVoltageCritical | Voltage is Critical | ||
| 1.3.6.1.4.1.10876.100.3.301 | NodetrapTemperatureNormal | Temperature has returned to Normal | ||
| 1.3.6.1.4.1.10876.100.3.302 | NodetrapTemperatureWarning | Temperature is Warning | ||
| 1.3.6.1.4.1.10876.100.3.303 | NodetrapTemperatureCritical | Temperature is Critical | ||
| 1.3.6.1.4.1.10876.100.3.401 | NodetrapChassisIntrusionCleared | Chassis Intrusion has cleared | ||
| 1.3.6.1.4.1.10876.100.3.403 | NodetrapChassisIntrusion | Chassis Intrusion has triggered | ||
| 1.3.6.1.4.1.10876.100.3.601 | NodetrapStorageSMARTCheckNormal | Storage SMART Check has returned to Normal | ||
| 1.3.6.1.4.1.10876.100.3.602 | NodetrapStorageSMARTCheckWarning | Storage SMART Check is Warning | ||
| 1.3.6.1.4.1.10876.100.3.603 | NodetrapStorageSMARTCheckCritical | Storage SMART Check is Critical | ||
| 1.3.6.1.4.1.10876.100.3.701 | NodetrapPowerSupplyNormal | Power Supply has returned to Normal | ||
| 1.3.6.1.4.1.10876.100.3.702 | NodetrapPowerSupplyWarning | Power Supply is Warning | ||
| 1.3.6.1.4.1.10876.100.3.703 | NodetrapPowerSupplyCritical | Power Supply is Critical | ||
| 1.3.6.1.4.1.10876.100.3.801 | NodetrapMemoryCeccNormal | Memory CECC has returned to Normal | ||
| 1.3.6.1.4.1.10876.100.3.802 | NodetrapMemoryCeccWarning | Memory CECC is Warning | ||
| 1.3.6.1.4.1.10876.100.3.803 | NodetrapMemoryCeccCritical | Memory CECC is Critical | ||
| 1.3.6.1.4.1.10876.100.3.901 | NodetrapMemoryUeccNormal | Memory UECC has returned to Normal | ||
| 1.3.6.1.4.1.10876.100.3.902 | NodetrapMemoryUeccWarning | Memory UECC is Warning | ||
| 1.3.6.1.4.1.10876.100.3.903 | NodetrapMemoryUeccCritical | Memory UECC Critical | ||
| 1.3.6.1.4.1.10876.100.3.1001 | NodetrapGenericNormal | Monitored item has returned to Normal | ||
| 1.3.6.1.4.1.10876.100.3.1002 | NodetrapGenericWarning | Monitored item is Warning | ||
| 1.3.6.1.4.1.10876.100.3.1003 | NodetrapGenericCritical | Monitored item Critical | ||
| 1.3.6.1.4.1.10876.100.3.1101 | NodetrapBbpStatusNormal | BBP has returned to Normal | ||
| 1.3.6.1.4.1.10876.100.3.1102 | NodetrapBbpStatusWarning | BBP is Warning | ||
| 1.3.6.1.4.1.10876.100.3.1103 | NodetrapBbpStatusCritical | BBP is Critical | ||
| 1.3.6.1.4.1.10876.100.3.1201 | NodetrapCpuFaultNormal | Processor Fault has returned to Normal | ||
| 1.3.6.1.4.1.10876.100.3.1202 | NodetrapCpuFaultWarning | Processor Fault is Warning | ||
| 1.3.6.1.4.1.10876.100.3.1203 | NodetrapCpuFaultCritical | Processor Fault is Critical | ||
| 1.3.6.1.4.1.10876.100.3.1301 | NodetrapStorageAdapterStatusNormal | Storage Adapter has returned to Normal | ||
| 1.3.6.1.4.1.10876.100.3.1302 | NodetrapStorageAdapterStatusWarning | Storage Adapter is Warning | ||
| 1.3.6.1.4.1.10876.100.3.1303 | NodetrapStorageAdapterStatusCritical | Storage Adapter is Critical | ||
| 1.3.6.1.4.1.10876.100.3.1401 | NodetrapBatteryStatusNormal | Battery has returned to Normal | ||
| 1.3.6.1.4.1.10876.100.3.1402 | NodetrapBatteryStatusWarning | Battery is Warning | ||
| 1.3.6.1.4.1.10876.100.3.1403 | NodetrapBatteryStatusCritical | Battery is Critical |