SYNLINK-MIB

173 objects
MIB File for SynLink PDUs SNMP functionality
Imported Objects
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIenterprises Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
SNMPv2-TCDisplayString TEXTUAL-CONVENTION TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.21728Nodesynaccess
1.3.6.1.4.1.21728.4IdentitysynlinkMIB File for SynLink PDUs SNMP functionality
1.3.6.1.4.1.21728.4.1Nodedevice
1.3.6.1.4.1.21728.4.1.1ScalarsynLinkModelread-onlycurrentThe model number of SynLink PDU
1.3.6.1.4.1.21728.4.1.2ScalarenclosureSerialNumberread-onlycurrentSerial number of SynLink PDU Controller and Enclosure
1.3.6.1.4.1.21728.4.1.3ScalarcontrollerSerialNumberread-onlycurrentSerial number of SynLink PDU Controller and Enclosure
1.3.6.1.4.1.21728.4.1.4ScalarinletConfigurationread-onlycurrentEither 'standard', 'dualcircuit', or 'ats'
1.3.6.1.4.1.21728.4.1.5ScalarnumOutletsread-onlycurrentNumber of outlets on PDU
1.3.6.1.4.1.21728.4.1.6ScalarnumBanksread-onlycurrentNumber of banks currently connected
1.3.6.1.4.1.21728.4.1.7Scalarphaseread-onlycurrent1 for single phase. 2 for 3 phase delta. 3 for 3 phase wye.
1.3.6.1.4.1.21728.4.1.8ScalarnumInletsread-onlycurrentNumber of Inlets. Either 1 or 2. ATS Dual inlets count as a single inlet.
1.3.6.1.4.1.21728.4.1.9ScalaroutletPwrMeasurementsSupportedread-onlycurrentDescribes if individual outlet current measurements is supported
1.3.6.1.4.1.21728.4.1.10ScalaroutletSwitchingSupportedread-onlycurrentDescribes if individual outlet switching is supported
1.3.6.1.4.1.21728.4.1.11ScalardeviceNameread-writecurrentUser defined name for device
1.3.6.1.4.1.21728.4.1.12ScalardeviceIpAddressread-onlycurrentIP Address for device.
1.3.6.1.4.1.21728.4.2Nodeinlets
1.3.6.1.4.1.21728.4.2.1TableinletTablenot-accessiblecurrentTable of all inlets entries. Inlet Entry includes information about plug type, power capacity number of poles and more.
1.3.6.1.4.1.21728.4.2.1.1RowinletEntrynot-accessiblecurrentInlet Object for an individual inlet instance.
1.3.6.1.4.1.21728.4.2.1.1.1ColumninletIndexnot-accessiblecurrentWhich number inlet it is.
1.3.6.1.4.1.21728.4.2.1.1.2ColumninletTyperead-onlycurrentDescribes which type of setup the inlet is part of. Single for one input plug. Double for two simultaneously used input plugs. ATS (Auto Transfer Switch) for 2…
1.3.6.1.4.1.21728.4.2.1.1.3ColumninletPlugread-onlycurrentThe type of Inlet Plug Connector.
1.3.6.1.4.1.21728.4.2.1.1.4ColumninletNameread-writecurrentUser defined name for Inlet
1.3.6.1.4.1.21728.4.2.1.1.5ColumninletEnergyAccumulationread-onlycurrentkWH value to show energy consumption for inlet plug
1.3.6.1.4.1.21728.4.2.1.1.6ColumninletPowerFactorread-onlycurrentPower factor value for inlet plug
1.3.6.1.4.1.21728.4.2.1.1.7ColumninletPhaseread-onlycurrentPossibilities are: Single Phase, 3 Phase Delta, or 3 Phase Wye
1.3.6.1.4.1.21728.4.2.1.1.8ColumninletUuidread-onlycurrentUnique identifier for Inlet
1.3.6.1.4.1.21728.4.2.1.1.9Columninlet3PhaseBalanceread-onlycurrentPercentage of imbalance in 3 phase inlet. Calculated with largest difference of any 2 lines, divided by average current. All times 100.
1.3.6.1.4.1.21728.4.2.1.1.10ColumninletLine1CurrentRmsread-onlycurrentLine 1 of 3 phase inlet Current RMS in Amperes
1.3.6.1.4.1.21728.4.2.1.1.11ColumninletLine2CurrentRmsread-onlycurrentLine 2 of 3 phase inlet Current RMS in Amperes
1.3.6.1.4.1.21728.4.2.1.1.12ColumninletLine3CurrentRmsread-onlycurrentLine 3 of 3 phase inlet Current RMS in Amperes
1.3.6.1.4.1.21728.4.2.1.1.13ColumninletLineConfigurationread-onlycurrentApplies only to single phase. Options are L-L, L-N, or L-L\N
1.3.6.1.4.1.21728.4.2.1.1.14ColumninletActivePowerread-onlycurrentInlet Active Power in watts
1.3.6.1.4.1.21728.4.2.1.1.15ColumninletApparentPowerread-onlycurrentInlet Apparent Power in Volt-amperes (VA)
1.3.6.1.4.1.21728.4.2.1.1.16ColumninletReactivePowerread-onlycurrentInlet Reactive Power in Volt-Amps-Reactive (VAR)
1.3.6.1.4.1.21728.4.2.1.1.17ColumninletCurrentRmsread-onlycurrentInlet current draw in amps
1.3.6.1.4.1.21728.4.2.1.1.18ColumninletLineFrequencyread-onlycurrentInlet line frequency in hertz
1.3.6.1.4.1.21728.4.2.1.1.19ColumninletVoltageRmsread-onlycurrentInlet voltage RMS in volts
1.3.6.1.4.1.21728.4.2.1.1.20ColumnatsActiveInletread-onlycurrentIf inputType is 'ats' then this value will be true if it is the currently used inlet. False if the inlet is not in use.
1.3.6.1.4.1.21728.4.2.1.1.21ColumnatsInletIdread-onlycurrentShould be A (primary) or B (secondary) for two ATS inputs
1.3.6.1.4.1.21728.4.2.1.1.22ColumnatsInletReadyread-onlycurrentWhether the Inlet is ready to be used as a power source
1.3.6.1.4.1.21728.4.4Nodebanks
1.3.6.1.4.1.21728.4.4.1TablebankTablenot-accessiblecurrentTable of bank instances.
1.3.6.1.4.1.21728.4.4.1.1RowbankEntrynot-accessiblecurrentBank object for a particular outlet bank.
1.3.6.1.4.1.21728.4.4.1.1.1ColumnbankIndexnot-accessiblecurrentWhich number bank it is.
1.3.6.1.4.1.21728.4.4.1.1.2ColumnbankUuidread-onlycurrentUnique Identifier for Bank
1.3.6.1.4.1.21728.4.4.1.1.3ColumnbankOutletSwitchingSupportedread-onlycurrentDescribes if bank outlets have relays for switching
1.3.6.1.4.1.21728.4.4.1.1.4ColumnbankOutletMeteringSupportedread-onlycurrentDescribes if bank outlets can measure individual outlet current in amps
1.3.6.1.4.1.21728.4.4.1.1.5ColumnbankCurrentRmsread-onlycurrentCurrent RMS of all outlets on bank in Amperes.
1.3.6.1.4.1.21728.4.4.1.1.6ColumnbankVoltageread-onlycurrentVoltage of bank.
1.3.6.1.4.1.21728.4.4.1.1.7ColumnbankLineFrequencyread-onlycurrentLine Frequency of bank.
1.3.6.1.4.1.21728.4.4.1.1.8ColumnbankPowerFactorread-onlycurrentBank Power factor
1.3.6.1.4.1.21728.4.4.1.1.9ColumnbankLinesread-onlycurrentSpecific Lines or line configuration which this bank is utilizing
1.3.6.1.4.1.21728.4.4.1.1.10ColumnbankActivePowerread-onlycurrentActive Power of bank.
1.3.6.1.4.1.21728.4.4.1.1.11ColumnbankReactivePowerread-onlycurrentReactive Power of bank.
1.3.6.1.4.1.21728.4.4.1.1.12ColumnbankApparentPowerread-onlycurrentApparent Power of bank.
1.3.6.1.4.1.21728.4.4.1.1.13ColumnbankNameread-writecurrentUser defined bank name.
1.3.6.1.4.1.21728.4.4.1.1.14ColumnbankBreakerSupportedread-onlycurrentTrue if bank has an associated over current protector.
1.3.6.1.4.1.21728.4.4.1.1.15ColumnbankBreakerStateread-onlycurrentTrue if breaker is working and not considered 'tripped'
1.3.6.1.4.1.21728.4.5Nodeoutlets
1.3.6.1.4.1.21728.4.5.1TableoutletTablenot-accessiblecurrentTable of outlet instances.
1.3.6.1.4.1.21728.4.5.1.1RowoutletEntrynot-accessiblecurrentOutlet object for a particular input line.
1.3.6.1.4.1.21728.4.5.1.1.1ColumnoutletIndexnot-accessiblecurrentWhich number outlet it is.
1.3.6.1.4.1.21728.4.5.1.1.2ColumnoutletUuidread-onlycurrentUnique identifier for outlet
1.3.6.1.4.1.21728.4.5.1.1.3ColumnoutletNameread-writecurrentUser defined name for outlet.
1.3.6.1.4.1.21728.4.5.1.1.6ColumnoutletCurrentRmsread-onlycurrentCurrent RMS in Amperes for individual outlet if supported.
1.3.6.1.4.1.21728.4.5.1.1.7ColumnoutletStateread-writecurrentState of relay. '0' means outlet is off (relay is open). '1' means outlet is on (relay is closed). Set '2' to power cycle outlet.
1.3.6.1.4.1.21728.4.5.1.1.8ColumnoutletConnectorread-onlycurrentType of Outlet Receptacle.
1.3.6.1.4.1.21728.4.6Nodegroups
1.3.6.1.4.1.21728.4.6.1TablegroupTablenot-accessiblecurrentTable of all outlet groups entries.
1.3.6.1.4.1.21728.4.6.1.1RowgroupEntrynot-accessiblecurrentGroup Object for a group of outlets.
1.3.6.1.4.1.21728.4.6.1.1.1ColumngroupIndexnot-accessiblecurrentWhich number group it is.
1.3.6.1.4.1.21728.4.6.1.1.2ColumngroupNameread-writecurrentUser defined name for group
1.3.6.1.4.1.21728.4.6.1.1.3ColumngroupUuidread-onlycurrentUnique identifier for group
1.3.6.1.4.1.21728.4.6.1.1.4ColumngroupSetStateread-writecurrentSet all outlets within state to given state. On for on, off for off.
1.3.6.1.4.1.21728.4.6.1.1.5ColumngroupRebootread-writecurrentReboot all outlets within a group
1.3.6.1.4.1.21728.4.6.1.1.6ColumngroupCurrentRmsread-onlycurrentCurrent RMS sum of all outlet current measurements. Available only of outlet metering supported.
1.3.6.1.4.1.21728.4.7Nodesensors
1.3.6.1.4.1.21728.4.7.1TablesensorTablenot-accessiblecurrentTable of Sensor entries.
1.3.6.1.4.1.21728.4.7.1.1RowsensorEntrynot-accessiblecurrentSensor instance.
1.3.6.1.4.1.21728.4.7.1.1.1ColumnsensorIndexnot-accessiblecurrentNumber of sensor
1.3.6.1.4.1.21728.4.7.1.1.2ColumnsensorTyperead-onlycurrentType of sensor. hum_temp for humidity & temp sensor
1.3.6.1.4.1.21728.4.7.1.1.3ColumnsensorTempread-onlycurrentTemperature if supported in celsius. sensorTempOffset is added to raw value to generate output of this OID.
1.3.6.1.4.1.21728.4.7.1.1.4ColumnsensorHumidityread-onlycurrentHumidity if supported in percentage humidity. sensorHumidityOffset is added to raw value to generate output of this OID.
1.3.6.1.4.1.21728.4.7.1.1.5ColumnsensorTempOffsetread-writecurrentOffset for temperature. Signed value.
1.3.6.1.4.1.21728.4.7.1.1.6ColumnsensorHumidityOffsetread-writecurrentOffset for humidity. Signed Value
1.3.6.1.4.1.21728.4.7.1.1.7ColumnsensorNameread-writecurrentUser defined name for sensor
1.3.6.1.4.1.21728.4.8Nodelogs
1.3.6.1.4.1.21728.4.8.1TablepowerLogTablenot-accessiblecurrentTable of all logging metric related to power
1.3.6.1.4.1.21728.4.8.1.1RowpowerLogEntrynot-accessiblecurrentInstance of logging metric
1.3.6.1.4.1.21728.4.8.1.1.1ColumnpwrLogIndexnot-accessiblecurrentID for log entry
1.3.6.1.4.1.21728.4.8.1.1.2ColumnpwrLogTyperead-onlycurrentType of logging metric. Can be
1.3.6.1.4.1.21728.4.8.1.1.3ColumnpwrLogValueread-onlycurrentVarious types. Current values.
1.3.6.1.4.1.21728.4.8.2TableenvironmentLogTablenot-accessiblecurrentTable of all logging metric related to temperature and humidity
1.3.6.1.4.1.21728.4.8.2.1RowenvironmentLogEntrynot-accessiblecurrentInstance of logging metric
1.3.6.1.4.1.21728.4.8.2.1.1ColumnenvLogIndexnot-accessiblecurrentID for log entry
1.3.6.1.4.1.21728.4.8.2.1.2ColumnenvLogTyperead-onlycurrentType of logging metric. Can be temp or humidity
1.3.6.1.4.1.21728.4.8.2.1.3ColumnenvLogValueread-onlycurrentEither temp in celsius or humidity in percentage
1.3.6.1.4.1.21728.4.9Nodeevents
1.3.6.1.4.1.21728.4.9.0NodeeventTraps
1.3.6.1.4.1.21728.4.9.0.1NotificationautopingTimeoutcurrentevent description
1.3.6.1.4.1.21728.4.9.0.2Notificationline1CurrentMaxThresholdcurrentLine 1 Max current trigger
1.3.6.1.4.1.21728.4.9.0.3Notificationline2CurrentMaxThresholdcurrentLine 2 Max current trigger
1.3.6.1.4.1.21728.4.9.0.4Notificationline3CurrentMaxThresholdcurrentLine 3 Max current trigger
1.3.6.1.4.1.21728.4.9.0.5Notificationline1CurrentMinThresholdcurrentLine 1 Max current trigger
1.3.6.1.4.1.21728.4.9.0.6Notificationline2CurrentMinThresholdcurrentLine 1 Max current trigger
1.3.6.1.4.1.21728.4.9.0.7Notificationline3CurrentMinThresholdcurrentLine 1 Max current trigger
1.3.6.1.4.1.21728.4.9.0.8NotificationinletCurrentMaxThresholdcurrentInlet Max Current Threshold Trigger. Applies to single phase PDUs Only
1.3.6.1.4.1.21728.4.9.0.9NotificationinletCurrentMinThresholdcurrentInlet Max Current Threshold Trigger. Applies to single phase PDUs Only
1.3.6.1.4.1.21728.4.9.0.10NotificationinletVoltageMaxThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.11NotificationinletVoltageMinThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.12NotificationinletLineFrequencyMaxThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.13NotificationinletLineFrequencyMinThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.14NotificationinletPowerFactorMinThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.15NotificationinletActiveEnergyMaxThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.16NotificationinletActivePowerMaxThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.17NotificationinletActivePowerMinThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.18NotificationinletApparentPowerMaxThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.19NotificationinletApparentPowerMinThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.20NotificationinletReactivePowerMaxThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.21NotificationinletReactivePowerMinThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.22Notificationinlet3phaseImbalancecurrentevent description
1.3.6.1.4.1.21728.4.9.0.23NotificationbankBreakerTripcurrentevent description
1.3.6.1.4.1.21728.4.9.0.24NotificationbankCurrentMaxThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.25NotificationbankCurrentMinThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.26NotificationbankVoltageMaxThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.27NotificationbankVoltageMinThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.28NotificationbankLineFrequencyMaxThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.29NotificationbankLineFrequencyMinThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.30NotificationbankPowerfactorMinThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.32NotificationbankActivePowerMaxThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.33NotificationbankActivePowerMinThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.34NotificationbankApparentPowerMaxThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.35NotificationbankApparentPowerMinThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.36NotificationbankReactivePowerMaxThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.37NotificationbankReactivePowerMinThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.38NotificationoutletCurrentMaxThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.39NotificationoutletCurrentMinThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.42NotificationtemperatureMaxThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.43NotificationtemperatureMinThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.44NotificationhumidityMaxThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.45NotificationhumidityMinThresholdcurrentevent description
1.3.6.1.4.1.21728.4.9.0.46NotificationscheduledTimecurrentevent description
1.3.6.1.4.1.21728.4.9.0.47NotificationscheduledIntervalcurrentevent description
1.3.6.1.4.1.21728.4.9.0.48NotificationatsInletSwitchedToSecondarycurrentevent description
1.3.6.1.4.1.21728.4.9.0.49NotificationatsInletSwitchedToPrimarycurrentevent description
1.3.6.1.4.1.21728.4.9.0.50NotificationatsInletSecondaryPowerLosscurrentevent description
1.3.6.1.4.1.21728.4.9.0.51NotificationatsInletSecondaryPowerRestoredcurrentevent description
1.3.6.1.4.1.21728.4.9.2NodeeventTriggers
1.3.6.1.4.1.21728.4.9.2.1TableeventTriggerTablenot-accessiblecurrentTable of all Event Triggers
1.3.6.1.4.1.21728.4.9.2.1.1RoweventTriggerEntrynot-accessiblecurrentInstance of Event Trigger
1.3.6.1.4.1.21728.4.9.2.1.1.1ColumneventTriggerIndexnot-accessiblecurrentID for event trigger entry
1.3.6.1.4.1.21728.4.9.2.1.1.2ColumneventTyperead-onlycurrentType of event. Can be any of traps. (Show Table)
1.3.6.1.4.1.21728.4.9.2.1.1.3ColumneventCoderead-onlycurrentUnique code for event
1.3.6.1.4.1.21728.4.9.2.1.1.4ColumneventNameread-onlycurrentUsed defined name for event trigger.
1.3.6.1.4.1.21728.4.9.2.1.1.5ColumneventTriggerAttr1read-onlycurrentFirst Attribute. See Event Table for details on specified Attr.
1.3.6.1.4.1.21728.4.9.2.1.1.6ColumneventTriggerAttr2read-onlycurrentSecond Attribute. See Event Table for details on specified Attr.
1.3.6.1.4.1.21728.4.9.2.1.1.7ColumneventTriggerAttr3read-onlycurrentThird Attribute. See Event Table for details on specified Attr.
1.3.6.1.4.1.21728.4.9.2.1.1.8ColumneventIsTriggeredread-onlycurrentDescribes whether or not the trigger has met it's threshold
1.3.6.1.4.1.21728.4.9.2.1.1.9ColumneventTriggeredTimeread-onlycurrentTime in seconds that this event has been triggered
1.3.6.1.4.1.21728.4.10Nodeconformance
1.3.6.1.4.1.21728.4.10.1NodesynLinkGroups
1.3.6.1.4.1.21728.4.10.1.1GroupsynLinkDeviceGroupcurrentDevice Objects Group
1.3.6.1.4.1.21728.4.10.1.2GroupsynLinkInletGroupcurrentInlet Objects Group
1.3.6.1.4.1.21728.4.10.1.4GroupsynLinkBankGroupcurrentBank Objects Group
1.3.6.1.4.1.21728.4.10.1.5GroupsynLinkOutletGroupcurrentOutlet Objects Group
1.3.6.1.4.1.21728.4.10.1.6GroupsynLinkGroupGroupcurrentOutlet Group Objects Group
1.3.6.1.4.1.21728.4.10.1.7GroupsynLinkSensorGroupcurrentSensor Objects Group
1.3.6.1.4.1.21728.4.10.1.8GroupsynLinkLogGroupcurrentLog Objects Group
1.3.6.1.4.1.21728.4.10.1.9GroupsynLinkEventGroupcurrentEvent Triggers Objects Group
1.3.6.1.4.1.21728.4.10.1.10GroupsynLinkTrapGroupcurrentEvent Trap Objects Groups
1.3.6.1.4.1.21728.4.10.2NodesynLinkCompliances
1.3.6.1.4.1.21728.4.10.2.1CompliancesynLinkCompliancecurrentRequirements for SYNLINK-MIB
Type Definitions
NameSyntaxStatusDescription
RelayEnumerationINTEGER { open(0), closed(1) }currentRelay States