Sentry4-MIB

419 objects
This is the MIB module for the fourth generation of the Sentry product family. This includes the PRO1 and PRO2 series of Smart and Switched Power Distribution Unit (PDU), Cabinet Distribution Unit (CDU), Universal Power Distribution Unit (UPDU), and Inline Meter products.
Imported Objects
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIenterprises Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
SNMPv2-TCDisplayString TEXTUAL-CONVENTION
OIDNameAccessStatusDescription
1.3.6.1.4.1.1718NodeserverTech
1.3.6.1.4.1.1718.4Identitysentry4This is the MIB module for the fourth generation of the Sentry product family. This includes the PRO1 and PRO2 series of Smart and Switched Power Distribution …
1.3.6.1.4.1.1718.4.1Nodest4Objects
1.3.6.1.4.1.1718.4.1.1Nodest4System
1.3.6.1.4.1.1718.4.1.1.1Nodest4SystemConfig
1.3.6.1.4.1.1718.4.1.1.1.1Scalarst4SystemProductNameread-onlycurrentThe product name.
1.3.6.1.4.1.1718.4.1.1.1.2Scalarst4SystemLocationread-writecurrentThe location of the system.
1.3.6.1.4.1.1718.4.1.1.1.3Scalarst4SystemFirmwareVersionread-onlycurrentThe firmware version.
1.3.6.1.4.1.1718.4.1.1.1.4Scalarst4SystemFirmwareBuildInforead-onlycurrentThe firmware build information.
1.3.6.1.4.1.1718.4.1.1.1.5Scalarst4SystemNICSerialNumberread-onlycurrentThe serial number of the network interface card.
1.3.6.1.4.1.1718.4.1.1.1.6Scalarst4SystemNICHardwareInforead-onlycurrentHardware information about the network interface card.
1.3.6.1.4.1.1718.4.1.1.1.7Scalarst4SystemProductSeriesread-onlycurrentThe product series.
1.3.6.1.4.1.1718.4.1.1.1.8Scalarst4SystemUptimeread-onlycurrentThe time in days, hours, minutes, and seconds since the network management portion of the system was last re-initialized.
1.3.6.1.4.1.1718.4.1.1.1.10Scalarst4SystemFeaturesread-onlycurrentThe key-activated features enabled in the system.
1.3.6.1.4.1.1718.4.1.1.1.11Scalarst4SystemFeatureKeyread-writecurrentA valid feature key written to this object will enable a feature in the system. A valid feature key is in the form xxxx-xxxx-xxxx-xxxx. A read of this object r…
1.3.6.1.4.1.1718.4.1.1.1.20Scalarst4SystemConfigModifiedCountread-onlycurrentThe total number of times the system configuration has changed.
1.3.6.1.4.1.1718.4.1.1.1.21Scalarst4SystemUnitCountread-onlycurrentThe number of units in the system.
1.3.6.1.4.1.1718.4.1.2Nodest4Units
1.3.6.1.4.1.1718.4.1.2.1Nodest4UnitCommonConfig
1.3.6.1.4.1.1718.4.1.2.2Tablest4UnitConfigTablenot-accessiblecurrentUnit configuration table.
1.3.6.1.4.1.1718.4.1.2.2.1Rowst4UnitConfigEntrynot-accessiblecurrentConfiguration objects for a particular unit.
1.3.6.1.4.1.1718.4.1.2.2.1.1Columnst4UnitIndexnot-accessiblecurrentUnit index. A=1, B=2, C=3, D=4, E=5, F=6.
1.3.6.1.4.1.1718.4.1.2.2.1.2Columnst4UnitIDread-onlycurrentThe internal ID of the unit. Format=A.
1.3.6.1.4.1.1718.4.1.2.2.1.3Columnst4UnitNameread-writecurrentThe name of the unit.
1.3.6.1.4.1.1718.4.1.2.2.1.4Columnst4UnitProductSNread-onlycurrentThe product serial number of the unit.
1.3.6.1.4.1.1718.4.1.2.2.1.5Columnst4UnitModelread-onlycurrentThe model of the unit.
1.3.6.1.4.1.1718.4.1.2.2.1.6Columnst4UnitAssetTagread-writecurrentThe asset tag of the unit.
1.3.6.1.4.1.1718.4.1.2.2.1.7Columnst4UnitTyperead-onlycurrentThe type of the unit.
1.3.6.1.4.1.1718.4.1.2.2.1.8Columnst4UnitCapabilitiesread-onlycurrentThe capabilities of the unit.
1.3.6.1.4.1.1718.4.1.2.2.1.9Columnst4UnitProductMfrDateread-onlycurrentThe product manufacture date in YYYY-MM-DD (ISO 8601 format) of the unit.
1.3.6.1.4.1.1718.4.1.2.2.1.20Columnst4UnitDisplayOrientationread-writecurrentThe orientation of all displays in the unit.
1.3.6.1.4.1.1718.4.1.2.2.1.21Columnst4UnitOutletSequenceOrderread-writecurrentThe sequencing order of all outlets in the unit.
1.3.6.1.4.1.1718.4.1.2.2.1.22Columnst4UnitOutletDisplayOrderread-writecurrentThe display order in the user interfaces of all outlets in the unit.
1.3.6.1.4.1.1718.4.1.2.2.1.30Columnst4UnitInputCordCountread-onlycurrentThe number of power input cords into the unit.
1.3.6.1.4.1.1718.4.1.2.2.1.31Columnst4UnitTempSensorCountread-onlycurrentThe number of external temperature sensors supported by the unit.
1.3.6.1.4.1.1718.4.1.2.2.1.32Columnst4UnitHumidSensorCountread-onlycurrentThe number of external humidity sensors supported by the unit.
1.3.6.1.4.1.1718.4.1.2.2.1.33Columnst4UnitWaterSensorCountread-onlycurrentThe number of external water sensors supported by the unit.
1.3.6.1.4.1.1718.4.1.2.2.1.34Columnst4UnitCcSensorCountread-onlycurrentThe number of external contact closure sensors supported by the unit.
1.3.6.1.4.1.1718.4.1.2.2.1.35Columnst4UnitAdcSensorCountread-onlycurrentThe number of analog-to-digital converter sensors supported by the unit.
1.3.6.1.4.1.1718.4.1.2.2.1.36Columnst4UnitFanSensorCountread-onlycurrentThe number of fan sensors supported by the unit.
1.3.6.1.4.1.1718.4.1.2.3Tablest4UnitMonitorTablenot-accessiblecurrentUnit monitor table.
1.3.6.1.4.1.1718.4.1.2.3.1Rowst4UnitMonitorEntrynot-accessiblecurrentObjects to monitor for a particular unit.
1.3.6.1.4.1.1718.4.1.2.3.1.1Columnst4UnitStatusread-onlycurrentThe status of the unit.
1.3.6.1.4.1.1718.4.1.2.4Tablest4UnitEventConfigTablenot-accessiblecurrentUnit event configuration table.
1.3.6.1.4.1.1718.4.1.2.4.1Rowst4UnitEventConfigEntrynot-accessiblecurrentEvent configuration objects for a particular unit.
1.3.6.1.4.1.1718.4.1.2.4.1.1Columnst4UnitNotificationsread-writecurrentThe notification methods enabled for unit events.
1.3.6.1.4.1.1718.4.1.3Nodest4InputCords
1.3.6.1.4.1.1718.4.1.3.1Nodest4InputCordCommonConfig
1.3.6.1.4.1.1718.4.1.3.1.1Scalarst4InputCordActivePowerHysteresisread-writecurrentThe active power hysteresis of the input cord in Watts.
1.3.6.1.4.1.1718.4.1.3.1.2Scalarst4InputCordApparentPowerHysteresisread-writecurrentThe apparent power hysteresis of the input cord in Volt-Amps.
1.3.6.1.4.1.1718.4.1.3.1.3Scalarst4InputCordPowerFactorHysteresisread-writecurrentThe power factor hysteresis of the input cord in hundredths.
1.3.6.1.4.1.1718.4.1.3.1.4Scalarst4InputCordOutOfBalanceHysteresisread-writecurrentThe 3 phase out-of-balance hysteresis of the input cord in percent.
1.3.6.1.4.1.1718.4.1.3.2Tablest4InputCordConfigTablenot-accessiblecurrentInput cord configuration table.
1.3.6.1.4.1.1718.4.1.3.2.1Rowst4InputCordConfigEntrynot-accessiblecurrentConfiguration objects for a particular input cord.
1.3.6.1.4.1.1718.4.1.3.2.1.1Columnst4InputCordIndexnot-accessiblecurrentInput cord index. A=1, B=2, C=3, D=4.
1.3.6.1.4.1.1718.4.1.3.2.1.2Columnst4InputCordIDread-onlycurrentThe internal ID of the input cord. Format=AA.
1.3.6.1.4.1.1718.4.1.3.2.1.3Columnst4InputCordNameread-writecurrentThe name of the input cord.
1.3.6.1.4.1.1718.4.1.3.2.1.6Columnst4InputCordInletTyperead-onlycurrentThe type of plug on the input cord, or socket for the input cord.
1.3.6.1.4.1.1718.4.1.3.2.1.7Columnst4InputCordNominalVoltageread-writecurrentThe user-configured nominal voltage of the input cord in tenth Volts.
1.3.6.1.4.1.1718.4.1.3.2.1.8Columnst4InputCordNominalVoltageMinread-onlycurrentThe factory-set minimum allowed for the user-configured nominal voltage of the input cord in Volts.
1.3.6.1.4.1.1718.4.1.3.2.1.9Columnst4InputCordNominalVoltageMaxread-onlycurrentThe factory-set maximum allowed for the user-configured nominal voltage of the input cord in Volts.
1.3.6.1.4.1.1718.4.1.3.2.1.10Columnst4InputCordCurrentCapacityread-writecurrentThe user-configured current capacity of the input cord in Amps.
1.3.6.1.4.1.1718.4.1.3.2.1.11Columnst4InputCordCurrentCapacityMaxread-onlycurrentThe factory-set maximum allowed for the user-configured current capacity of the input cord in Amps.
1.3.6.1.4.1.1718.4.1.3.2.1.12Columnst4InputCordPowerCapacityread-onlycurrentThe power capacity of the input cord in Volt-Amps. For DC products, this is identical to power capacity in Watts.
1.3.6.1.4.1.1718.4.1.3.2.1.13Columnst4InputCordNominalPowerFactorread-writecurrentThe user-configured estimated nominal power factor of the input cord in hundredths.
1.3.6.1.4.1.1718.4.1.3.2.1.20Columnst4InputCordLineCountread-onlycurrentThe number of current-carrying lines in the input cord.
1.3.6.1.4.1.1718.4.1.3.2.1.21Columnst4InputCordPhaseCountread-onlycurrentThe number of active phases from the lines in the input cord.
1.3.6.1.4.1.1718.4.1.3.2.1.22Columnst4InputCordOcpCountread-onlycurrentThe number of over-current protectors downstream from the input cord.
1.3.6.1.4.1.1718.4.1.3.2.1.23Columnst4InputCordBranchCountread-onlycurrentThe number of branches downstream from the input cord.
1.3.6.1.4.1.1718.4.1.3.2.1.24Columnst4InputCordOutletCountread-onlycurrentThe number of outlets powered from the input cord.
1.3.6.1.4.1.1718.4.1.3.3Tablest4InputCordMonitorTablenot-accessiblecurrentInput cord monitor table.
1.3.6.1.4.1.1718.4.1.3.3.1Rowst4InputCordMonitorEntrynot-accessiblecurrentObjects to monitor for a particular input cord.
1.3.6.1.4.1.1718.4.1.3.3.1.1Columnst4InputCordStateread-onlycurrentThe on/off state of the input cord.
1.3.6.1.4.1.1718.4.1.3.3.1.2Columnst4InputCordStatusread-onlycurrentThe status of the input cord.
1.3.6.1.4.1.1718.4.1.3.3.1.3Columnst4InputCordActivePowerread-onlycurrentThe measured active power of the input cord in Watts.
1.3.6.1.4.1.1718.4.1.3.3.1.4Columnst4InputCordActivePowerStatusread-onlycurrentThe status of the measured active power of the input cord.
1.3.6.1.4.1.1718.4.1.3.3.1.5Columnst4InputCordApparentPowerread-onlycurrentThe measured apparent power of the input cord in Volt-Amps.
1.3.6.1.4.1.1718.4.1.3.3.1.6Columnst4InputCordApparentPowerStatusread-onlycurrentThe status of the measured apparent power of the input cord.
1.3.6.1.4.1.1718.4.1.3.3.1.7Columnst4InputCordPowerUtilizedread-onlycurrentThe amount of the input cord power capacity used in tenth percent. For AC products, this is the ratio of the apparent power to the power capacity. For DC produ…
1.3.6.1.4.1.1718.4.1.3.3.1.8Columnst4InputCordPowerFactorread-onlycurrentThe measured power factor of the input cord in hundredths.
1.3.6.1.4.1.1718.4.1.3.3.1.9Columnst4InputCordPowerFactorStatusread-onlycurrentThe status of the measured power factor of the input cord.
1.3.6.1.4.1.1718.4.1.3.3.1.10Columnst4InputCordEnergyread-onlycurrentThe total energy consumption of loads through the input cord in tenth Kilowatt-Hours.
1.3.6.1.4.1.1718.4.1.3.3.1.11Columnst4InputCordFrequencyread-onlycurrentThe frequency of the input cord voltage in tenth Hertz.
1.3.6.1.4.1.1718.4.1.3.3.1.12Columnst4InputCordOutOfBalanceread-onlycurrentThe current imbalance on the lines of the input cord in tenth percent.
1.3.6.1.4.1.1718.4.1.3.3.1.13Columnst4InputCordOutOfBalanceStatusread-onlycurrentThe status of the current imbalance on the lines of the input cord.
1.3.6.1.4.1.1718.4.1.3.4Tablest4InputCordEventConfigTablenot-accessiblecurrentInput cord event configuration table.
1.3.6.1.4.1.1718.4.1.3.4.1Rowst4InputCordEventConfigEntrynot-accessiblecurrentEvent configuration objects for a particular input cord.
1.3.6.1.4.1.1718.4.1.3.4.1.1Columnst4InputCordNotificationsread-writecurrentThe notification methods enabled for input cord events.
1.3.6.1.4.1.1718.4.1.3.4.1.2Columnst4InputCordActivePowerLowAlarmread-writecurrentThe active power low alarm threshold of the input cord in Watts.
1.3.6.1.4.1.1718.4.1.3.4.1.3Columnst4InputCordActivePowerLowWarningread-writecurrentThe active power low warning threshold of the input cord in Watts.
1.3.6.1.4.1.1718.4.1.3.4.1.4Columnst4InputCordActivePowerHighWarningread-writecurrentThe active power high warning threshold of the input cord in Watts.
1.3.6.1.4.1.1718.4.1.3.4.1.5Columnst4InputCordActivePowerHighAlarmread-writecurrentThe active power high alarm threshold of the input cord in Watts.
1.3.6.1.4.1.1718.4.1.3.4.1.6Columnst4InputCordApparentPowerLowAlarmread-writecurrentThe apparent power low alarm threshold of the input cord in Volt-Amps.
1.3.6.1.4.1.1718.4.1.3.4.1.7Columnst4InputCordApparentPowerLowWarningread-writecurrentThe apparent power low warning threshold of the input cord in Volt-Amps.
1.3.6.1.4.1.1718.4.1.3.4.1.8Columnst4InputCordApparentPowerHighWarningread-writecurrentThe apparent power high warning threshold of the input cord in Volt-Amps.
1.3.6.1.4.1.1718.4.1.3.4.1.9Columnst4InputCordApparentPowerHighAlarmread-writecurrentThe apparent power high alarm threshold of the input cord in Volt-Amps.
1.3.6.1.4.1.1718.4.1.3.4.1.10Columnst4InputCordPowerFactorLowAlarmread-writecurrentThe power factor low alarm threshold of the input cord in hundredths.
1.3.6.1.4.1.1718.4.1.3.4.1.11Columnst4InputCordPowerFactorLowWarningread-writecurrentThe power factor low warning threshold of the input cord in hundredths.
1.3.6.1.4.1.1718.4.1.3.4.1.12Columnst4InputCordOutOfBalanceHighWarningread-writecurrentThe 3 phase out-of-balance high warning threshold of the input cord in percent.
1.3.6.1.4.1.1718.4.1.3.4.1.13Columnst4InputCordOutOfBalanceHighAlarmread-writecurrentThe 3 phase out-of-balance high alarm threshold of the input cord in percent.
1.3.6.1.4.1.1718.4.1.4Nodest4Lines
1.3.6.1.4.1.1718.4.1.4.1Nodest4LineCommonConfig
1.3.6.1.4.1.1718.4.1.4.1.1Scalarst4LineCurrentHysteresisread-writecurrentThe current hysteresis of the line in tenth Amps.
1.3.6.1.4.1.1718.4.1.4.2Tablest4LineConfigTablenot-accessiblecurrentLine configuration table.
1.3.6.1.4.1.1718.4.1.4.2.1Rowst4LineConfigEntrynot-accessiblecurrentConfiguration objects for a particular line.
1.3.6.1.4.1.1718.4.1.4.2.1.1Columnst4LineIndexnot-accessiblecurrentLine index. L1=1, L2=2, L3=3, N=4.
1.3.6.1.4.1.1718.4.1.4.2.1.2Columnst4LineIDread-onlycurrentThe internal ID of the line. Format=AAN.
1.3.6.1.4.1.1718.4.1.4.2.1.4Columnst4LineLabelread-onlycurrentThe system label assigned to the line for identification.
1.3.6.1.4.1.1718.4.1.4.2.1.6Columnst4LineCurrentCapacityread-onlycurrentThe current capacity of the line in Amps.
1.3.6.1.4.1.1718.4.1.4.3Tablest4LineMonitorTablenot-accessiblecurrentLine monitor table.
1.3.6.1.4.1.1718.4.1.4.3.1Rowst4LineMonitorEntrynot-accessiblecurrentObjects to monitor for a particular line.
1.3.6.1.4.1.1718.4.1.4.3.1.1Columnst4LineStateread-onlycurrentThe on/off state of the line.
1.3.6.1.4.1.1718.4.1.4.3.1.2Columnst4LineStatusread-onlycurrentThe status of the line.
1.3.6.1.4.1.1718.4.1.4.3.1.3Columnst4LineCurrentread-onlycurrentThe measured current on the line in hundredth Amps.
1.3.6.1.4.1.1718.4.1.4.3.1.4Columnst4LineCurrentStatusread-onlycurrentThe status of the measured current on the line.
1.3.6.1.4.1.1718.4.1.4.3.1.5Columnst4LineCurrentUtilizedread-onlycurrentThe amount of the line current capacity used in tenth percent.
1.3.6.1.4.1.1718.4.1.4.4Tablest4LineEventConfigTablenot-accessiblecurrentLine event configuration table.
1.3.6.1.4.1.1718.4.1.4.4.1Rowst4LineEventConfigEntrynot-accessiblecurrentEvent configuration objects for a particular line.
1.3.6.1.4.1.1718.4.1.4.4.1.1Columnst4LineNotificationsread-writecurrentThe notification methods enabled for line events.
1.3.6.1.4.1.1718.4.1.4.4.1.2Columnst4LineCurrentLowAlarmread-writecurrentThe current low alarm threshold of the line in tenth Amps.
1.3.6.1.4.1.1718.4.1.4.4.1.3Columnst4LineCurrentLowWarningread-writecurrentThe current low warning threshold of the line in tenth Amps.
1.3.6.1.4.1.1718.4.1.4.4.1.4Columnst4LineCurrentHighWarningread-writecurrentThe current high warning threshold of the line in tenth Amps.
1.3.6.1.4.1.1718.4.1.4.4.1.5Columnst4LineCurrentHighAlarmread-writecurrentThe current high alarm threshold of the line in tenth Amps.
1.3.6.1.4.1.1718.4.1.5Nodest4Phases
1.3.6.1.4.1.1718.4.1.5.1Nodest4PhaseCommonConfig
1.3.6.1.4.1.1718.4.1.5.1.1Scalarst4PhaseVoltageHysteresisread-writecurrentThe voltage hysteresis of the phase in tenth Volts.
1.3.6.1.4.1.1718.4.1.5.1.2Scalarst4PhasePowerFactorHysteresisread-writecurrentThe power factor hysteresis of the phase in hundredths.
1.3.6.1.4.1.1718.4.1.5.2Tablest4PhaseConfigTablenot-accessiblecurrentPhase configuration table.
1.3.6.1.4.1.1718.4.1.5.2.1Rowst4PhaseConfigEntrynot-accessiblecurrentConfiguration objects for a particular phase.
1.3.6.1.4.1.1718.4.1.5.2.1.1Columnst4PhaseIndexnot-accessiblecurrentPhase index. Three-phase AC Wye: L1-N=1, L2-N=2, L3-N=3; Three-phase AC Delta: L1-L2=1, L2-L3=2, L3-L1=3; Single Phase: L1-R=1; DC: L1-R=1; Three-phase AC Wye …
1.3.6.1.4.1.1718.4.1.5.2.1.2Columnst4PhaseIDread-onlycurrentThe internal ID of the phase. Format=AAN.
1.3.6.1.4.1.1718.4.1.5.2.1.4Columnst4PhaseLabelread-onlycurrentThe system label assigned to the phase for identification.
1.3.6.1.4.1.1718.4.1.5.2.1.6Columnst4PhaseNominalVoltageread-onlycurrentThe nominal voltage of the phase in tenth Volts.
1.3.6.1.4.1.1718.4.1.5.2.1.20Columnst4PhaseBranchCountread-onlycurrentThe number of branches downstream from the phase.
1.3.6.1.4.1.1718.4.1.5.2.1.21Columnst4PhaseOutletCountread-onlycurrentThe number of outlets powered from the phase.
1.3.6.1.4.1.1718.4.1.5.3Tablest4PhaseMonitorTablenot-accessiblecurrentPhase monitor table.
1.3.6.1.4.1.1718.4.1.5.3.1Rowst4PhaseMonitorEntrynot-accessiblecurrentObjects to monitor for a particular phase.
1.3.6.1.4.1.1718.4.1.5.3.1.1Columnst4PhaseStateread-onlycurrentThe on/off state of the phase.
1.3.6.1.4.1.1718.4.1.5.3.1.2Columnst4PhaseStatusread-onlycurrentThe status of the phase.
1.3.6.1.4.1.1718.4.1.5.3.1.3Columnst4PhaseVoltageread-onlycurrentThe measured voltage on the phase in tenth Volts.
1.3.6.1.4.1.1718.4.1.5.3.1.4Columnst4PhaseVoltageStatusread-onlycurrentThe status of the measured voltage on the phase.
1.3.6.1.4.1.1718.4.1.5.3.1.5Columnst4PhaseVoltageDeviationread-onlycurrentThe deviation from the nominal voltage on the phase in tenth percent.
1.3.6.1.4.1.1718.4.1.5.3.1.6Columnst4PhaseCurrentread-onlycurrentThe measured current on the phase in hundredth Amps.
1.3.6.1.4.1.1718.4.1.5.3.1.7Columnst4PhaseCurrentCrestFactorread-onlycurrentThe measured crest factor of the current waveform on the phase in tenths.
1.3.6.1.4.1.1718.4.1.5.3.1.8Columnst4PhaseActivePowerread-onlycurrentThe measured active power on the phase in Watts.
1.3.6.1.4.1.1718.4.1.5.3.1.9Columnst4PhaseApparentPowerread-onlycurrentThe measured apparent power on the phase in Volt-Amps.
1.3.6.1.4.1.1718.4.1.5.3.1.10Columnst4PhasePowerFactorread-onlycurrentThe measured power factor on the phase in hundredths.
1.3.6.1.4.1.1718.4.1.5.3.1.11Columnst4PhasePowerFactorStatusread-onlycurrentThe status of the measured power factor on the phase.
1.3.6.1.4.1.1718.4.1.5.3.1.12Columnst4PhaseReactanceread-onlycurrentThe status of the measured reactance of the phase.
1.3.6.1.4.1.1718.4.1.5.3.1.13Columnst4PhaseEnergyread-onlycurrentThe total energy consumption of loads through the phase in tenth Kilowatt-Hours.
1.3.6.1.4.1.1718.4.1.5.4Tablest4PhaseEventConfigTablenot-accessiblecurrentPhase event configuration table.
1.3.6.1.4.1.1718.4.1.5.4.1Rowst4PhaseEventConfigEntrynot-accessiblecurrentEvent configuration objects for a particular phase.
1.3.6.1.4.1.1718.4.1.5.4.1.1Columnst4PhaseNotificationsread-writecurrentThe notification methods enabled for phase events.
1.3.6.1.4.1.1718.4.1.5.4.1.2Columnst4PhaseVoltageLowAlarmread-writecurrentThe current low alarm threshold of the phase in tenth Volts.
1.3.6.1.4.1.1718.4.1.5.4.1.3Columnst4PhaseVoltageLowWarningread-writecurrentThe current low warning threshold of the phase in tenth Volts.
1.3.6.1.4.1.1718.4.1.5.4.1.4Columnst4PhaseVoltageHighWarningread-writecurrentThe current high warning threshold of the phase in tenth Volts.
1.3.6.1.4.1.1718.4.1.5.4.1.5Columnst4PhaseVoltageHighAlarmread-writecurrentThe current high alarm threshold of the phase in tenth Volts.
1.3.6.1.4.1.1718.4.1.5.4.1.6Columnst4PhasePowerFactorLowAlarmread-writecurrentThe low power factor alarm threshold of the phase in hundredths.
1.3.6.1.4.1.1718.4.1.5.4.1.7Columnst4PhasePowerFactorLowWarningread-writecurrentThe low power factor warning threshold of the phase in hundredths.
1.3.6.1.4.1.1718.4.1.6Nodest4OverCurrentProtectors
1.3.6.1.4.1.1718.4.1.6.1Nodest4OcpCommonConfig
1.3.6.1.4.1.1718.4.1.6.2Tablest4OcpConfigTablenot-accessiblecurrentOver-current protector configuration table.
1.3.6.1.4.1.1718.4.1.6.2.1Rowst4OcpConfigEntrynot-accessiblecurrentConfiguration objects for a particular over-current protector.
1.3.6.1.4.1.1718.4.1.6.2.1.1Columnst4OcpIndexnot-accessiblecurrentOver-current protector index.
1.3.6.1.4.1.1718.4.1.6.2.1.2Columnst4OcpIDread-onlycurrentThe internal ID of the over-current protector. Format=AAN[N].
1.3.6.1.4.1.1718.4.1.6.2.1.4Columnst4OcpLabelread-onlycurrentThe system label assigned to the over-current protector for identification.
1.3.6.1.4.1.1718.4.1.6.2.1.6Columnst4OcpTyperead-onlycurrentThe type of over-current protector.
1.3.6.1.4.1.1718.4.1.6.2.1.7Columnst4OcpCurrentCapacityread-writecurrentThe user-configured current capacity of the over-current protector in Amps.
1.3.6.1.4.1.1718.4.1.6.2.1.8Columnst4OcpCurrentCapacityMaxread-onlycurrentThe factory-set maximum allowed for the user-configured current capacity of the over-current protector in Amps.
1.3.6.1.4.1.1718.4.1.6.2.1.20Columnst4OcpBranchCountread-onlycurrentThe number of branches downstream from the over-current protector.
1.3.6.1.4.1.1718.4.1.6.2.1.21Columnst4OcpOutletCountread-onlycurrentThe number of outlets powered from the over-current protector.
1.3.6.1.4.1.1718.4.1.6.3Tablest4OcpMonitorTablenot-accessiblecurrentOver-current protector monitor table.
1.3.6.1.4.1.1718.4.1.6.3.1Rowst4OcpMonitorEntrynot-accessiblecurrentObjects to monitor for a particular over-current protector.
1.3.6.1.4.1.1718.4.1.6.3.1.1Columnst4OcpStatusread-onlycurrentThe status of the over-current protector.
1.3.6.1.4.1.1718.4.1.6.4Tablest4OcpEventConfigTablenot-accessiblecurrentOver-current protector event configuration table.
1.3.6.1.4.1.1718.4.1.6.4.1Rowst4OcpEventConfigEntrynot-accessiblecurrentEvent configuration objects for a particular over-current protector.
1.3.6.1.4.1.1718.4.1.6.4.1.1Columnst4OcpNotificationsread-writecurrentThe notification methods enabled for over-current protector events.
1.3.6.1.4.1.1718.4.1.7Nodest4Branches
1.3.6.1.4.1.1718.4.1.7.1Nodest4BranchCommonConfig
1.3.6.1.4.1.1718.4.1.7.1.1Scalarst4BranchCurrentHysteresisread-writecurrentThe current hysteresis of the branch in tenth Amps.
1.3.6.1.4.1.1718.4.1.7.2Tablest4BranchConfigTablenot-accessiblecurrentBranch configuration table.
1.3.6.1.4.1.1718.4.1.7.2.1Rowst4BranchConfigEntrynot-accessiblecurrentConfiguration objects for a particular branch.
1.3.6.1.4.1.1718.4.1.7.2.1.1Columnst4BranchIndexnot-accessiblecurrentBranch index.
1.3.6.1.4.1.1718.4.1.7.2.1.2Columnst4BranchIDread-onlycurrentThe internal ID of the branch. Format=AAN[N].
1.3.6.1.4.1.1718.4.1.7.2.1.4Columnst4BranchLabelread-onlycurrentThe system label assigned to the branch for identification.
1.3.6.1.4.1.1718.4.1.7.2.1.6Columnst4BranchCurrentCapacityread-onlycurrentThe current capacity of the branch in Amps.
1.3.6.1.4.1.1718.4.1.7.2.1.20Columnst4BranchPhaseIDread-onlycurrentThe internal ID of the phase powering this branch. Format=AAN.
1.3.6.1.4.1.1718.4.1.7.2.1.21Columnst4BranchOcpIDread-onlycurrentThe internal ID of the over-current protector powering this outlet. Format=AAN[N].
1.3.6.1.4.1.1718.4.1.7.2.1.30Columnst4BranchOutletCountread-onlycurrentThe number of outlets powered from the branch.
1.3.6.1.4.1.1718.4.1.7.3Tablest4BranchMonitorTablenot-accessiblecurrentBranch monitor table.
1.3.6.1.4.1.1718.4.1.7.3.1Rowst4BranchMonitorEntrynot-accessiblecurrentObjects to monitor for a particular branch.
1.3.6.1.4.1.1718.4.1.7.3.1.1Columnst4BranchStateread-onlycurrentThe on/off state of the branch.
1.3.6.1.4.1.1718.4.1.7.3.1.2Columnst4BranchStatusread-onlycurrentThe status of the branch.
1.3.6.1.4.1.1718.4.1.7.3.1.3Columnst4BranchCurrentread-onlycurrentThe measured current on the branch in hundredth Amps.
1.3.6.1.4.1.1718.4.1.7.3.1.4Columnst4BranchCurrentStatusread-onlycurrentThe status of the measured current on the branch.
1.3.6.1.4.1.1718.4.1.7.3.1.5Columnst4BranchCurrentUtilizedread-onlycurrentThe amount of the branch current capacity used in tenth percent.
1.3.6.1.4.1.1718.4.1.7.4Tablest4BranchEventConfigTablenot-accessiblecurrentBranch event configuration table.
1.3.6.1.4.1.1718.4.1.7.4.1Rowst4BranchEventConfigEntrynot-accessiblecurrentEvent configuration objects for a particular branch.
1.3.6.1.4.1.1718.4.1.7.4.1.1Columnst4BranchNotificationsread-writecurrentThe notification methods enabled for branch events.
1.3.6.1.4.1.1718.4.1.7.4.1.2Columnst4BranchCurrentLowAlarmread-writecurrentThe current low alarm threshold of the branch in tenth Amps.
1.3.6.1.4.1.1718.4.1.7.4.1.3Columnst4BranchCurrentLowWarningread-writecurrentThe current low warning threshold of the branch in tenth Amps.
1.3.6.1.4.1.1718.4.1.7.4.1.4Columnst4BranchCurrentHighWarningread-writecurrentThe current high warning threshold of the branch in tenth Amps.
1.3.6.1.4.1.1718.4.1.7.4.1.5Columnst4BranchCurrentHighAlarmread-writecurrentThe current high alarm threshold of the branch in tenth Amps.
1.3.6.1.4.1.1718.4.1.8Nodest4Outlets
1.3.6.1.4.1.1718.4.1.8.1Nodest4OutletCommonConfig
1.3.6.1.4.1.1718.4.1.8.1.1Scalarst4OutletCurrentHysteresisread-writecurrentThe current hysteresis of the outlet in tenth Amps.
1.3.6.1.4.1.1718.4.1.8.1.2Scalarst4OutletActivePowerHysteresisread-writecurrentThe power hysteresis of the outlet in Watts.
1.3.6.1.4.1.1718.4.1.8.1.3Scalarst4OutletPowerFactorHysteresisread-writecurrentThe power factor hysteresis of the outlet in hundredths.
1.3.6.1.4.1.1718.4.1.8.1.10Scalarst4OutletSequenceIntervalread-writecurrentThe power-on sequencing interval for all outlets in seconds.
1.3.6.1.4.1.1718.4.1.8.1.11Scalarst4OutletRebootDelayread-writecurrentThe reboot delay for all outlets in seconds.
1.3.6.1.4.1.1718.4.1.8.1.12Scalarst4OutletStateChangeLoggingread-writecurrentEnables or disables informational Outlet State Change event logging.
1.3.6.1.4.1.1718.4.1.8.2Tablest4OutletConfigTablenot-accessiblecurrentOutlet configuration table.
1.3.6.1.4.1.1718.4.1.8.2.1Rowst4OutletConfigEntrynot-accessiblecurrentConfiguration objects for a particular outlet.
1.3.6.1.4.1.1718.4.1.8.2.1.1Columnst4OutletIndexnot-accessiblecurrentOutlet index.
1.3.6.1.4.1.1718.4.1.8.2.1.2Columnst4OutletIDread-onlycurrentThe internal ID of the outlet. Format=AAN[N[N]].
1.3.6.1.4.1.1718.4.1.8.2.1.3Columnst4OutletNameread-writecurrentThe name of the outlet.
1.3.6.1.4.1.1718.4.1.8.2.1.5Columnst4OutletCapabilitiesread-onlycurrentThe capabilities of the outlet.
1.3.6.1.4.1.1718.4.1.8.2.1.6Columnst4OutletSocketTyperead-onlycurrentThe socket type of the outlet.
1.3.6.1.4.1.1718.4.1.8.2.1.7Columnst4OutletCurrentCapacityread-onlycurrentThe current capacity of the outlet in Amps.
1.3.6.1.4.1.1718.4.1.8.2.1.8Columnst4OutletPowerCapacityread-onlycurrentThe power capacity of the outlet in Volt-Amps. For DC products, this is identical to power capacity in Watts.
1.3.6.1.4.1.1718.4.1.8.2.1.9Columnst4OutletSocketAdapterread-writecurrentThe manually-selected or automatically-detected socket adapter of the outlet.
1.3.6.1.4.1.1718.4.1.8.2.1.20Columnst4OutletWakeupStateread-writecurrentThe wakeup state of the outlet.
1.3.6.1.4.1.1718.4.1.8.2.1.21Columnst4OutletPostOnDelayread-writecurrentThe post-on delay of the outlet in seconds.
1.3.6.1.4.1.1718.4.1.8.2.1.30Columnst4OutletPhaseIDread-onlycurrentThe internal ID of the phase powering this outlet. Format=AAN.
1.3.6.1.4.1.1718.4.1.8.2.1.31Columnst4OutletOcpIDread-onlycurrentThe internal ID of the over-current protector powering this outlet. Format=AAN[N].
1.3.6.1.4.1.1718.4.1.8.2.1.32Columnst4OutletBranchIDread-onlycurrentThe internal ID of the branch powering this outlet. Format=AAN[N].
1.3.6.1.4.1.1718.4.1.8.3Tablest4OutletMonitorTablenot-accessiblecurrentOutlet monitor table.
1.3.6.1.4.1.1718.4.1.8.3.1Rowst4OutletMonitorEntrynot-accessiblecurrentObjects to monitor for a particular outlet.
1.3.6.1.4.1.1718.4.1.8.3.1.1Columnst4OutletStateread-onlycurrentThe on/off state of the outlet.
1.3.6.1.4.1.1718.4.1.8.3.1.2Columnst4OutletStatusread-onlycurrentThe status of the outlet.
1.3.6.1.4.1.1718.4.1.8.3.1.3Columnst4OutletCurrentread-onlycurrentThe measured current on the outlet in hundredth Amps.
1.3.6.1.4.1.1718.4.1.8.3.1.4Columnst4OutletCurrentStatusread-onlycurrentThe status of the measured current on the outlet.
1.3.6.1.4.1.1718.4.1.8.3.1.5Columnst4OutletCurrentUtilizedread-onlycurrentThe amount of the outlet current capacity used in tenth percent.
1.3.6.1.4.1.1718.4.1.8.3.1.6Columnst4OutletVoltageread-onlycurrentThe measured voltage of the outlet in tenth Volts.
1.3.6.1.4.1.1718.4.1.8.3.1.7Columnst4OutletActivePowerread-onlycurrentThe measured active power of the outlet in Watts.
1.3.6.1.4.1.1718.4.1.8.3.1.8Columnst4OutletActivePowerStatusread-onlycurrentThe status of the measured active power of the outlet.
1.3.6.1.4.1.1718.4.1.8.3.1.9Columnst4OutletApparentPowerread-onlycurrentThe measured apparent power of the outlet in Volt-Amps.
1.3.6.1.4.1.1718.4.1.8.3.1.10Columnst4OutletPowerFactorread-onlycurrentThe measured power factor of the outlet in hundredths.
1.3.6.1.4.1.1718.4.1.8.3.1.11Columnst4OutletPowerFactorStatusread-onlycurrentThe status of the measured power factor of the outlet.
1.3.6.1.4.1.1718.4.1.8.3.1.12Columnst4OutletCurrentCrestFactorread-onlycurrentThe measured crest factor of the outlet in tenths.
1.3.6.1.4.1.1718.4.1.8.3.1.13Columnst4OutletReactanceread-onlycurrentThe status of the measured reactance of the outlet.
1.3.6.1.4.1.1718.4.1.8.3.1.14Columnst4OutletEnergyread-onlycurrentThe total energy consumption of the device plugged into the outlet in Watt-Hours.
1.3.6.1.4.1.1718.4.1.8.4Tablest4OutletEventConfigTablenot-accessiblecurrentOutlet event configuration table.
1.3.6.1.4.1.1718.4.1.8.4.1Rowst4OutletEventConfigEntrynot-accessiblecurrentEvent configuration objects for a particular outlet.
1.3.6.1.4.1.1718.4.1.8.4.1.1Columnst4OutletNotificationsread-writecurrentThe notification methods enabled for outlet events.
1.3.6.1.4.1.1718.4.1.8.4.1.2Columnst4OutletCurrentLowAlarmread-writecurrentThe current low alarm threshold of the outlet in tenth Amps.
1.3.6.1.4.1.1718.4.1.8.4.1.3Columnst4OutletCurrentLowWarningread-writecurrentThe current low warning threshold of the outlet in tenth Amps.
1.3.6.1.4.1.1718.4.1.8.4.1.4Columnst4OutletCurrentHighWarningread-writecurrentThe current high warning threshold of the outlet in tenth Amps.
1.3.6.1.4.1.1718.4.1.8.4.1.5Columnst4OutletCurrentHighAlarmread-writecurrentThe current high alarm threshold of the outlet in tenth Amps.
1.3.6.1.4.1.1718.4.1.8.4.1.6Columnst4OutletActivePowerLowAlarmread-writecurrentThe active power low alarm threshold of the outlet in Watts.
1.3.6.1.4.1.1718.4.1.8.4.1.7Columnst4OutletActivePowerLowWarningread-writecurrentThe active power low warning threshold of the outlet in Watts.
1.3.6.1.4.1.1718.4.1.8.4.1.8Columnst4OutletActivePowerHighWarningread-writecurrentThe active power high warning threshold of the outlet in Watts.
1.3.6.1.4.1.1718.4.1.8.4.1.9Columnst4OutletActivePowerHighAlarmread-writecurrentThe active power high alarm threshold of the outlet in Watts.
1.3.6.1.4.1.1718.4.1.8.4.1.10Columnst4OutletPowerFactorLowAlarmread-writecurrentThe low power factor alarm threshold of the outlet in hundredths.
1.3.6.1.4.1.1718.4.1.8.4.1.11Columnst4OutletPowerFactorLowWarningread-writecurrentThe low power factor warning threshold of the outlet in hundredths.
1.3.6.1.4.1.1718.4.1.8.5Tablest4OutletControlTablenot-accessiblecurrentOutlet control table.
1.3.6.1.4.1.1718.4.1.8.5.1Rowst4OutletControlEntrynot-accessiblecurrentObjects for control of a particular outlet.
1.3.6.1.4.1.1718.4.1.8.5.1.1Columnst4OutletControlStateread-onlycurrentThe control state of the outlet.
1.3.6.1.4.1.1718.4.1.8.5.1.2Columnst4OutletControlActionread-writecurrentAn action to change the control state of the outlet, or to queue an action.
1.3.6.1.4.1.1718.4.1.8.6Nodest4OutletCommonControl
1.3.6.1.4.1.1718.4.1.8.6.1Scalarst4OutletQueueControlread-writecurrentAn action to clear or commit queued outlet control actions. A read of this object returns clear(0) if queue is empty, and commit(1) if the queue is not empty.
1.3.6.1.4.1.1718.4.1.9Nodest4TemperatureSensors
1.3.6.1.4.1.1718.4.1.9.1Nodest4TempSensorCommonConfig
1.3.6.1.4.1.1718.4.1.9.1.1Scalarst4TempSensorHysteresisread-writecurrentThe temperature hysteresis of the sensor in degrees, using the scale selected by st4TempSensorScale.
1.3.6.1.4.1.1718.4.1.9.1.10Scalarst4TempSensorScaleread-writecurrentThe current scale used for all temperature values.
1.3.6.1.4.1.1718.4.1.9.2Tablest4TempSensorConfigTablenot-accessiblecurrentTemperature sensor configuration table.
1.3.6.1.4.1.1718.4.1.9.2.1Rowst4TempSensorConfigEntrynot-accessiblecurrentConfiguration objects for a particular temperature sensor.
1.3.6.1.4.1.1718.4.1.9.2.1.1Columnst4TempSensorIndexnot-accessiblecurrentTemperature sensor index.
1.3.6.1.4.1.1718.4.1.9.2.1.2Columnst4TempSensorIDread-onlycurrentThe internal ID of the temperature sensor. Format=AN.
1.3.6.1.4.1.1718.4.1.9.2.1.3Columnst4TempSensorNameread-writecurrentThe name of the temperature sensor.
1.3.6.1.4.1.1718.4.1.9.2.1.4Columnst4TempSensorValueMinread-onlycurrentThe minimum temperature limit of the sensor in degrees, using the scale selected by st4TempSensorScale.
1.3.6.1.4.1.1718.4.1.9.2.1.5Columnst4TempSensorValueMaxread-onlycurrentThe maximum temperature limit of the sensor in degrees, using the scale selected by st4TempSensorScale.
1.3.6.1.4.1.1718.4.1.9.3Tablest4TempSensorMonitorTablenot-accessiblecurrentTemperature sensor monitor table.
1.3.6.1.4.1.1718.4.1.9.3.1Rowst4TempSensorMonitorEntrynot-accessiblecurrentObjects to monitor for a particular temperature sensor.
1.3.6.1.4.1.1718.4.1.9.3.1.1Columnst4TempSensorValueread-onlycurrentThe measured temperature on the sensor in tenth degrees using the scale selected by st4TempSensorScale. -410 means the temperature reading is invalid.
1.3.6.1.4.1.1718.4.1.9.3.1.2Columnst4TempSensorStatusread-onlycurrentThe status of the temperature sensor.
1.3.6.1.4.1.1718.4.1.9.4Tablest4TempSensorEventConfigTablenot-accessiblecurrentTemperature sensor event configuration table.
1.3.6.1.4.1.1718.4.1.9.4.1Rowst4TempSensorEventConfigEntrynot-accessiblecurrentEvent configuration objects for a particular temperature sensor.
1.3.6.1.4.1.1718.4.1.9.4.1.1Columnst4TempSensorNotificationsread-writecurrentThe notification methods enabled for temperature sensor events.
1.3.6.1.4.1.1718.4.1.9.4.1.2Columnst4TempSensorLowAlarmread-writecurrentThe low alarm threshold of the temperature sensor in degrees.
1.3.6.1.4.1.1718.4.1.9.4.1.3Columnst4TempSensorLowWarningread-writecurrentThe low warning threshold of the temperature sensor in degrees.
1.3.6.1.4.1.1718.4.1.9.4.1.4Columnst4TempSensorHighWarningread-writecurrentThe high warning threshold of the temperature sensor in degrees.
1.3.6.1.4.1.1718.4.1.9.4.1.5Columnst4TempSensorHighAlarmread-writecurrentThe high alarm threshold of the temperature sensor in degrees.
1.3.6.1.4.1.1718.4.1.10Nodest4HumiditySensors
1.3.6.1.4.1.1718.4.1.10.1Nodest4HumidSensorCommonConfig
1.3.6.1.4.1.1718.4.1.10.1.1Scalarst4HumidSensorHysteresisread-writecurrentThe humidity hysteresis of the sensor in percent relative humidity.
1.3.6.1.4.1.1718.4.1.10.2Tablest4HumidSensorConfigTablenot-accessiblecurrentHumidity sensor configuration table.
1.3.6.1.4.1.1718.4.1.10.2.1Rowst4HumidSensorConfigEntrynot-accessiblecurrentConfiguration objects for a particular humidity sensor.
1.3.6.1.4.1.1718.4.1.10.2.1.1Columnst4HumidSensorIndexnot-accessiblecurrentHumidity sensor index.
1.3.6.1.4.1.1718.4.1.10.2.1.2Columnst4HumidSensorIDread-onlycurrentThe internal ID of the humidity sensor. Format=AN.
1.3.6.1.4.1.1718.4.1.10.2.1.3Columnst4HumidSensorNameread-writecurrentThe name of the humidity sensor.
1.3.6.1.4.1.1718.4.1.10.3Tablest4HumidSensorMonitorTablenot-accessiblecurrentHumidity sensor monitor table.
1.3.6.1.4.1.1718.4.1.10.3.1Rowst4HumidSensorMonitorEntrynot-accessiblecurrentObjects to monitor for a particular humidity sensor.
1.3.6.1.4.1.1718.4.1.10.3.1.1Columnst4HumidSensorValueread-onlycurrentThe measured humidity on the sensor in percentage relative humidity.
1.3.6.1.4.1.1718.4.1.10.3.1.2Columnst4HumidSensorStatusread-onlycurrentThe status of the humidity sensor.
1.3.6.1.4.1.1718.4.1.10.4Tablest4HumidSensorEventConfigTablenot-accessiblecurrentHumidity sensor event configuration table.
1.3.6.1.4.1.1718.4.1.10.4.1Rowst4HumidSensorEventConfigEntrynot-accessiblecurrentEvent configuration objects for a particular humidity sensor.
1.3.6.1.4.1.1718.4.1.10.4.1.1Columnst4HumidSensorNotificationsread-writecurrentThe notification methods enabled for humidity sensor events.
1.3.6.1.4.1.1718.4.1.10.4.1.2Columnst4HumidSensorLowAlarmread-writecurrentThe low alarm threshold of the humidity sensor in percentage relative humidity.
1.3.6.1.4.1.1718.4.1.10.4.1.3Columnst4HumidSensorLowWarningread-writecurrentThe low warning threshold of the humidity sensor in percentage relative humidity.
1.3.6.1.4.1.1718.4.1.10.4.1.4Columnst4HumidSensorHighWarningread-writecurrentThe high warning threshold of the humidity sensor in percentage relative humidity.
1.3.6.1.4.1.1718.4.1.10.4.1.5Columnst4HumidSensorHighAlarmread-writecurrentThe high alarm threshold of the humidity sensor in percentage relative humidity.
1.3.6.1.4.1.1718.4.1.11Nodest4WaterSensors
1.3.6.1.4.1.1718.4.1.11.1Nodest4WaterSensorCommonConfig
1.3.6.1.4.1.1718.4.1.11.2Tablest4WaterSensorConfigTablenot-accessiblecurrentWater sensor configuration table.
1.3.6.1.4.1.1718.4.1.11.2.1Rowst4WaterSensorConfigEntrynot-accessiblecurrentConfiguration objects for a particular water sensor.
1.3.6.1.4.1.1718.4.1.11.2.1.1Columnst4WaterSensorIndexnot-accessiblecurrentWater sensor index.
1.3.6.1.4.1.1718.4.1.11.2.1.2Columnst4WaterSensorIDread-onlycurrentThe internal ID of the water sensor. Format=AN.
1.3.6.1.4.1.1718.4.1.11.2.1.3Columnst4WaterSensorNameread-writecurrentThe name of the water sensor.
1.3.6.1.4.1.1718.4.1.11.3Tablest4WaterSensorMonitorTablenot-accessiblecurrentWater sensor monitor table.
1.3.6.1.4.1.1718.4.1.11.3.1Rowst4WaterSensorMonitorEntrynot-accessiblecurrentObjects to monitor for a particular water sensor.
1.3.6.1.4.1.1718.4.1.11.3.1.1Columnst4WaterSensorStatusread-onlycurrentThe status of the water sensor.
1.3.6.1.4.1.1718.4.1.11.4Tablest4WaterSensorEventConfigTablenot-accessiblecurrentWater sensor event configuration table.
1.3.6.1.4.1.1718.4.1.11.4.1Rowst4WaterSensorEventConfigEntrynot-accessiblecurrentEvent configuration objects for a particular water sensor.
1.3.6.1.4.1.1718.4.1.11.4.1.1Columnst4WaterSensorNotificationsread-writecurrentThe notification methods enabled for water sensor events.
1.3.6.1.4.1.1718.4.1.12Nodest4ContactClosureSensors
1.3.6.1.4.1.1718.4.1.12.1Nodest4CcSensorCommonConfig
1.3.6.1.4.1.1718.4.1.12.2Tablest4CcSensorConfigTablenot-accessiblecurrentContact closure sensor configuration table.
1.3.6.1.4.1.1718.4.1.12.2.1Rowst4CcSensorConfigEntrynot-accessiblecurrentConfiguration objects for a particular contact closure sensor.
1.3.6.1.4.1.1718.4.1.12.2.1.1Columnst4CcSensorIndexnot-accessiblecurrentContact closure sensor index.
1.3.6.1.4.1.1718.4.1.12.2.1.2Columnst4CcSensorIDread-onlycurrentThe internal ID of the contact closure sensor. Format=AN.
1.3.6.1.4.1.1718.4.1.12.2.1.3Columnst4CcSensorNameread-writecurrentThe name of the contact closure sensor.
1.3.6.1.4.1.1718.4.1.12.3Tablest4CcSensorMonitorTablenot-accessiblecurrentContact closure sensor monitor table.
1.3.6.1.4.1.1718.4.1.12.3.1Rowst4CcSensorMonitorEntrynot-accessiblecurrentObjects to monitor for a particular contact closure sensor.
1.3.6.1.4.1.1718.4.1.12.3.1.1Columnst4CcSensorStatusread-onlycurrentThe status of the contact closure.
1.3.6.1.4.1.1718.4.1.12.4Tablest4CcSensorEventConfigTablenot-accessiblecurrentContact closure sensor event configuration table.
1.3.6.1.4.1.1718.4.1.12.4.1Rowst4CcSensorEventConfigEntrynot-accessiblecurrentEvent configuration objects for a particular contact closure sensor.
1.3.6.1.4.1.1718.4.1.12.4.1.1Columnst4CcSensorNotificationsread-writecurrentThe notification methods enabled for contact closure sensor events.
1.3.6.1.4.1.1718.4.1.13Nodest4AnalogToDigitalConvSensors
1.3.6.1.4.1.1718.4.1.13.1Nodest4AdcSensorCommonConfig
1.3.6.1.4.1.1718.4.1.13.1.1Scalarst4AdcSensorHysteresisread-writecurrentThe 8-bit count hysteresis of the analog-to-digital converter sensor.
1.3.6.1.4.1.1718.4.1.13.2Tablest4AdcSensorConfigTablenot-accessiblecurrentAnalog-to-digital converter sensor configuration table.
1.3.6.1.4.1.1718.4.1.13.2.1Rowst4AdcSensorConfigEntrynot-accessiblecurrentConfiguration objects for a particular analog-to-digital converter sensor.
1.3.6.1.4.1.1718.4.1.13.2.1.1Columnst4AdcSensorIndexnot-accessiblecurrentAnalog-to-digital converter sensor index.
1.3.6.1.4.1.1718.4.1.13.2.1.2Columnst4AdcSensorIDread-onlycurrentThe internal ID of the analog-to-digital converter sensor. Format=AN.
1.3.6.1.4.1.1718.4.1.13.2.1.3Columnst4AdcSensorNameread-writecurrentThe name of the analog-to-digital converter sensor.
1.3.6.1.4.1.1718.4.1.13.3Tablest4AdcSensorMonitorTablenot-accessiblecurrentAnalog-to-digital converter sensor monitor table.
1.3.6.1.4.1.1718.4.1.13.3.1Rowst4AdcSensorMonitorEntrynot-accessiblecurrentObjects to monitor for a particular analog-to-digital converter sensor.
1.3.6.1.4.1.1718.4.1.13.3.1.1Columnst4AdcSensorValueread-onlycurrentThe 8-bit value from the analog-to-digital converter sensor.
1.3.6.1.4.1.1718.4.1.13.3.1.2Columnst4AdcSensorStatusread-onlycurrentThe status of the analog-to-digital converter sensor.
1.3.6.1.4.1.1718.4.1.13.4Tablest4AdcSensorEventConfigTablenot-accessiblecurrentAnalog-to-digital converter sensor event configuration table.
1.3.6.1.4.1.1718.4.1.13.4.1Rowst4AdcSensorEventConfigEntrynot-accessiblecurrentEvent configuration objects for a particular analog-to-digital converter sensor.
1.3.6.1.4.1.1718.4.1.13.4.1.1Columnst4AdcSensorNotificationsread-writecurrentThe notification methods enabled for analog-to-digital converter sensor events.
1.3.6.1.4.1.1718.4.1.13.4.1.2Columnst4AdcSensorLowAlarmread-writecurrentThe 8-bit value for the low alarm threshold of the analog-to-digital converter sensor.
1.3.6.1.4.1.1718.4.1.13.4.1.3Columnst4AdcSensorLowWarningread-writecurrentThe 8-bit value for the low warning threshold of the analog-to-digital converter sensor.
1.3.6.1.4.1.1718.4.1.13.4.1.4Columnst4AdcSensorHighWarningread-writecurrentThe 8-bit value for the high warning threshold of the analog-to-digital converter sensor.
1.3.6.1.4.1.1718.4.1.13.4.1.5Columnst4AdcSensorHighAlarmread-writecurrentThe 8-bit value for the high alarm threshold of the analog-to-digital converter sensor.
1.3.6.1.4.1.1718.4.1.14Nodest4FanSensors
1.3.6.1.4.1.1718.4.1.14.1Nodest4FanSensorCommonConfig
1.3.6.1.4.1.1718.4.1.14.1.1Scalarst4FanSensorHysteresisread-writecurrentThe fan speed hysteresis of the sensor in rotations per minute.
1.3.6.1.4.1.1718.4.1.14.2Tablest4FanSensorConfigTablenot-accessiblecurrentFan sensor configuration table.
1.3.6.1.4.1.1718.4.1.14.2.1Rowst4FanSensorConfigEntrynot-accessiblecurrentConfiguration objects for a particular fan sensor.
1.3.6.1.4.1.1718.4.1.14.2.1.1Columnst4FanSensorIndexnot-accessiblecurrentFan sensor index.
1.3.6.1.4.1.1718.4.1.14.2.1.2Columnst4FanSensorIDread-onlycurrentThe internal ID of the fan sensor. Format=AN.
1.3.6.1.4.1.1718.4.1.14.2.1.3Columnst4FanSensorNameread-writecurrentThe name of the fan sensor.
1.3.6.1.4.1.1718.4.1.14.3Tablest4FanSensorMonitorTablenot-accessiblecurrentFan sensor monitor table.
1.3.6.1.4.1.1718.4.1.14.3.1Rowst4FanSensorMonitorEntrynot-accessiblecurrentObjects to monitor for a particular fan sensor.
1.3.6.1.4.1.1718.4.1.14.3.1.1Columnst4FanSensorValueread-onlycurrentThe measured fan speed of the sensor in rotations per minute.
1.3.6.1.4.1.1718.4.1.14.3.1.2Columnst4FanSensorStatusread-onlycurrentThe status of the fan sensor.
1.3.6.1.4.1.1718.4.1.14.4Tablest4FanSensorEventConfigTablenot-accessiblecurrentFan sensor event configuration table.
1.3.6.1.4.1.1718.4.1.14.4.1Rowst4FanSensorEventConfigEntrynot-accessiblecurrentEvent configuration objects for a particular fan sensor.
1.3.6.1.4.1.1718.4.1.14.4.1.1Columnst4FanSensorNotificationsread-writecurrentThe notification methods enabled for fan sensor events.
1.3.6.1.4.1.1718.4.1.14.4.1.2Columnst4FanSensorLowAlarmread-writecurrentThe low alarm threshold of the fan sensor in rotations per minute.
1.3.6.1.4.1.1718.4.1.14.4.1.3Columnst4FanSensorLowWarningread-writecurrentThe low warning threshold of the fan sensor in rotations per minute.
1.3.6.1.4.1.1718.4.1.14.4.1.4Columnst4FanSensorHighWarningread-writecurrentThe high warning threshold of the fan sensor in rotations per minute.
1.3.6.1.4.1.1718.4.1.14.4.1.5Columnst4FanSensorHighAlarmread-writecurrentThe high alarm threshold of the fan sensor in rotations per minute.
1.3.6.1.4.1.1718.4.1.99Nodest4EventInformation
1.3.6.1.4.1.1718.4.1.99.1Scalarst4EventStatusTextread-onlycurrentThe text representation of the enumerated integer value of the most-relevant status or state object included in a trap. The value of this object is set only wh…
1.3.6.1.4.1.1718.4.1.99.2Scalarst4EventStatusConditionread-onlycurrentThe condition of the enumerated integer value of the status object included in a trap. The value of this object is set only when sent with a trap. A read of th…
1.3.6.1.4.1.1718.4.100Nodest4Notifications
1.3.6.1.4.1.1718.4.100.0Nodest4Events
1.3.6.1.4.1.1718.4.100.0.1Notificationst4UnitStatusEventcurrentUnit status event.
1.3.6.1.4.1.1718.4.100.0.2Notificationst4InputCordStatusEventcurrentInput cord status event.
1.3.6.1.4.1.1718.4.100.0.3Notificationst4InputCordActivePowerEventcurrentInput cord active power event.
1.3.6.1.4.1.1718.4.100.0.4Notificationst4InputCordApparentPowerEventcurrentInput cord apparent power event.
1.3.6.1.4.1.1718.4.100.0.5Notificationst4InputCordPowerFactorEventcurrentInput cord power factor event.
1.3.6.1.4.1.1718.4.100.0.6Notificationst4InputCordOutOfBalanceEventcurrentInput cord out-of-balance event.
1.3.6.1.4.1.1718.4.100.0.7Notificationst4LineStatusEventcurrentLine status event.
1.3.6.1.4.1.1718.4.100.0.8Notificationst4LineCurrentEventcurrentLine current event.
1.3.6.1.4.1.1718.4.100.0.9Notificationst4PhaseStatusEventcurrentPhase status event.
1.3.6.1.4.1.1718.4.100.0.10Notificationst4PhaseVoltageEventcurrentPhase voltage event.
1.3.6.1.4.1.1718.4.100.0.11Notificationst4PhasePowerFactorEventcurrentPhase voltage event.
1.3.6.1.4.1.1718.4.100.0.12Notificationst4OcpStatusEventcurrentOver-current protector status event.
1.3.6.1.4.1.1718.4.100.0.13Notificationst4BranchStatusEventcurrentBranch status event.
1.3.6.1.4.1.1718.4.100.0.14Notificationst4BranchCurrentEventcurrentBranch current event.
1.3.6.1.4.1.1718.4.100.0.15Notificationst4OutletStatusEventcurrentOutlet status event.
1.3.6.1.4.1.1718.4.100.0.16Notificationst4OutletStateChangeEventcurrentOutlet state change event.
1.3.6.1.4.1.1718.4.100.0.17Notificationst4OutletCurrentEventcurrentOutlet current event.
1.3.6.1.4.1.1718.4.100.0.18Notificationst4OutletActivePowerEventcurrentOutlet active power event.
1.3.6.1.4.1.1718.4.100.0.19Notificationst4OutletPowerFactorEventcurrentOutlet power factor event.
1.3.6.1.4.1.1718.4.100.0.20Notificationst4TempSensorEventcurrentTemperature sensor event.
1.3.6.1.4.1.1718.4.100.0.21Notificationst4HumidSensorEventcurrentHumidity sensor event.
1.3.6.1.4.1.1718.4.100.0.22Notificationst4WaterSensorStatusEventcurrentWater sensor status event.
1.3.6.1.4.1.1718.4.100.0.23Notificationst4CcSensorStatusEventcurrentContact closure sensor status event.
1.3.6.1.4.1.1718.4.100.0.24Notificationst4AdcSensorEventcurrentAnalog-to-digital converter sensor event.
1.3.6.1.4.1.1718.4.100.0.25Notificationst4FanSensorEventcurrentFan sensor event.
1.3.6.1.4.1.1718.4.200Nodest4Conformance
1.3.6.1.4.1.1718.4.200.1Nodest4Groups
1.3.6.1.4.1.1718.4.200.1.1Groupst4SystemObjectsGroupcurrentSystem objects group.
1.3.6.1.4.1.1718.4.200.1.2Groupst4UnitObjectsGroupcurrentUnit objects group.
1.3.6.1.4.1.1718.4.200.1.3Groupst4InputCordObjectsGroupcurrentInput cord objects group.
1.3.6.1.4.1.1718.4.200.1.4Groupst4LineObjectsGroupcurrentLine objects group.
1.3.6.1.4.1.1718.4.200.1.5Groupst4PhaseObjectsGroupcurrentPhase objects group.
1.3.6.1.4.1.1718.4.200.1.6Groupst4OcpObjectsGroupcurrentOver-current protector objects group.
1.3.6.1.4.1.1718.4.200.1.7Groupst4BranchObjectsGroupcurrentBranch objects group.
1.3.6.1.4.1.1718.4.200.1.8Groupst4OutletObjectsGroupcurrentOutlet objects group.
1.3.6.1.4.1.1718.4.200.1.9Groupst4TempSensorObjectsGroupcurrentTemperature sensor objects group.
1.3.6.1.4.1.1718.4.200.1.10Groupst4HumidSensorObjectsGroupcurrentHumidity sensor objects group.
1.3.6.1.4.1.1718.4.200.1.11Groupst4WaterSensorObjectsGroupcurrentWater sensor objects group.
1.3.6.1.4.1.1718.4.200.1.12Groupst4CcSensorObjectsGroupcurrentContact closure sensor objects group.
1.3.6.1.4.1.1718.4.200.1.13Groupst4AdcSensorObjectsGroupcurrentAnalog-to-digital converter sensor objects group.
1.3.6.1.4.1.1718.4.200.1.14Groupst4FanSensorObjectsGroupcurrentFan sensor objects group.
1.3.6.1.4.1.1718.4.200.1.99Groupst4EventInfoObjectsGroupcurrentEvent information objects group.
1.3.6.1.4.1.1718.4.200.1.100Groupst4EventNotificationsGroupcurrentEvent notifications group.
1.3.6.1.4.1.1718.4.200.2Nodest4Compliances
1.3.6.1.4.1.1718.4.200.2.1Compliancest4ModuleCompliancescurrentThe requirements for conformance to the Sentry4-MIB.
Type Definitions
NameSyntaxStatusDescription
DeviceStateINTEGER { unknown(0), on(1), off(2) }currentOn or off state of devices.
DeviceStatusINTEGER { normal(0), disabled(1), purged(2), reading(5), settle(6), notFound(7), lost(8), readError(9), noComm(10), pwrError(11), breakerTripped(12), fuseBlown(13), lowAlarm(14), lowWarning(15), highWarning(16), highAlarm(17), alarm(18), underLimit(19), overLimit(20), nvmFail(21), profileError(22), conflict(23) }currentStatus returned by devices.
EventNotificationMethodsBITS { snmpTrap(0), email(1) }currentBits to enable event notification methods.