MIB Viewer

TELESTE-COMMON-MIB

121 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212OBJECT-TYPE
RFC1155-SMICounter IpAddress
RFC1213-MIBDisplayString
TELESTE-ROOT-MIBcommon DateAndTime TPhysAddress Uint16
OIDNameAccessStatusDescription
1.3.6.1.4.1.3715.99.1Nodeelement
1.3.6.1.4.1.3715.99.1.1NodeelementInformation
1.3.6.1.4.1.3715.99.1.1.1ScalarelementNameread-writemandatoryThis is the logical name of the controlling module of the network element. The name may or may not be the same as the module's name in the moduleTable.
1.3.6.1.4.1.3715.99.1.1.2ScalarelementStructureread-onlymandatoryThis object tells whether the device is a single compact device or a modular device.
1.3.6.1.4.1.3715.99.1.1.3ScalarelementConfigChangeCoderead-onlyoptionalThis object is an indicator about changes in the network element configuration. How the value is formed is device dependent. It can be a counter, a checksum of…
1.3.6.1.4.1.3715.99.1.1.4ScalarelementResetCountread-onlyoptionalTotal number of software resets during the device's life time.
1.3.6.1.4.1.3715.99.1.1.5ScalarelementTotalUpTimeread-onlymandatoryThe total uptime the device (software) has been running. Unit 1 day.
1.3.6.1.4.1.3715.99.1.1.6ScalarelementLatituderead-writeoptionalDevice latitude coordinate. Unit 0.00001 degrees.
1.3.6.1.4.1.3715.99.1.1.7ScalarelementLongituderead-writeoptionalDevice longitude coordinate. Unit 0.00001 degrees.
1.3.6.1.4.1.3715.99.1.1.8ScalarelementAltituderead-writeoptionalDevice altitude coordinate. Unit 1 metre.
1.3.6.1.4.1.3715.99.1.2NodeelementStatus
1.3.6.1.4.1.3715.99.1.2.1ScalarstatusGeneralread-onlymandatoryA number stating the general status of the element. Values: 1 = Normal 2 = At least one Notification is active 3 = At least one Warning is active 4 = At least …
1.3.6.1.4.1.3715.99.1.2.2ScalarstatusBusMasterread-onlyoptionalA number stating the Bus Master status of the NE. Values: 1 = The NE is a slave-only device 2 = The NE is configured as slave 3 = The NE is configured as maste…
1.3.6.1.4.1.3715.99.1.2.3ScalarstatusLmtread-onlyoptionalA number telling if the Local Management Terminal (LMT) is connected to the element. Values: 1 = The element does not have an LMT interface 2 = The element can…
1.3.6.1.4.1.3715.99.1.2.4ScalarstatusLidread-onlyoptionalElement lid status: 1 = no lid (no lid sensor is available) 2 = lid is closed 3 = lid is open
1.3.6.1.4.1.3715.99.1.2.5ScalarstatusTemperatureread-onlyoptionalElement temperature status: 1 = normal 2 = HIHI 3 = Hi 4 = Lo 5 = LOLO
1.3.6.1.4.1.3715.99.1.2.6ScalarstatusFanread-onlymandatoryA common status object for all fans in the device. fanNormal(1) = all fans operate normally fanFailure(2) = at least one fan has a failure
1.3.6.1.4.1.3715.99.1.2.7ScalarstatusHardwareread-onlymandatoryDevice hardware status: hwNormal(1) = the hardware operates normally hwFailure(2) = a hardware failure is detected
1.3.6.1.4.1.3715.99.1.2.8ScalarstatusSoftwareread-onlymandatoryDevice software status: swNormal(1) = the software operates normally swFailure(2) = a software failure is detected swMissing(3) = the software or firmware is m…
1.3.6.1.4.1.3715.99.1.2.9ScalarstatusSettingsread-onlymandatoryStatus of device settings: settingsStable(1) = settings are stable settingsChanged(2) = settings have been (recently) changed settingsNotAvailable(3) = setting…
1.3.6.1.4.1.3715.99.1.3NodeelementControl
1.3.6.1.4.1.3715.99.1.3.1ScalarcontrolResetElementread-writemandatoryOn write requests this object commands the module to reset itself. If softReset(3) or hardReset(2) can not be performed, then BAD VALUE error is returned. On r…
1.3.6.1.4.1.3715.99.1.3.2ScalarcontrolBusMasterAdminStateread-writeoptionalThis object tells whether the element is configured as a bus master or not. Only relevant for bus master type of elements. Others return no(2).
1.3.6.1.4.1.3715.99.1.3.3ScalarcontrolAlarmDetectionread-writemandatoryThis variable is used to disable or enable the element alarm checking. When disabled(1), the element will not check any alarms (or send traps). Default value i…
1.3.6.1.4.1.3715.99.1.3.4ScalarcontrolMaxNumberTrapReceiversread-onlymandatoryNumber of entries in the elementTrapReceiverTable. At least one trap entry must be supported.
1.3.6.1.4.1.3715.99.1.3.5TablecontrolTrapReceiverTablenot-accessibleoptionalA table of manager trap receiver addresses, ports and communities. Total number of entries can not exceed elementNumberTrapReceivers. An entry is deleted from …
1.3.6.1.4.1.3715.99.1.3.5.1RowcontrolTrapReceiverEntrynot-accessibleoptional
1.3.6.1.4.1.3715.99.1.3.5.1.1ColumnreceiverEntryIdread-onlymandatoryUnique table index. Makes possible to have several ip-address of 0.0.0.0 entries so that no mechanism for row manipulation of table is needed.
1.3.6.1.4.1.3715.99.1.3.5.1.2ColumnreceiverAddressread-writemandatoryIp address of the manager receiving Traps.
1.3.6.1.4.1.3715.99.1.3.5.1.3ColumnreceiverPortread-writemandatoryTrap UDP port number. Default port is the standard trap port 162.
1.3.6.1.4.1.3715.99.1.3.5.1.4ColumnreceiverCommunityread-writemandatoryCommunity string for the trap receiver. The agent is allowed to limit the length of the string. Minimum length of eight characters must be supported. Note: one…
1.3.6.1.4.1.3715.99.1.3.6ScalarcontrolTrapSendingread-writeoptionalEnables/disables trap sending. 1 = traps enabled 2 = traps disabled
1.3.6.1.4.1.3715.99.1.3.7ScalarcontrolTrapIntervalread-writeoptionalThe minimum interval between traps. - Unit 10 milliseconds - Minimum value 0 (send as fast as possible) - Maximum value 1000 (10 seconds) - Default value is 10…
1.3.6.1.4.1.3715.99.1.3.8ScalarcontrolTrapLifeTimeread-writeoptionalThe maximum time a trap stays in the trap queue waiting for sending. - Unit 1 second. - Minimum value 10 - Maximum value 300 - Default value 60
1.3.6.1.4.1.3715.99.1.3.9ScalarcontrolAlarmOnDelayread-writeoptionalThe minimum time an object's alarm/warning condition must exist before it is recorded as an alarm/warning. Common to all alarms/warnings - Unit 10 ms - Minimum…
1.3.6.1.4.1.3715.99.1.3.10ScalarcontrolAlarmOffDelayread-writeoptionalThe minimum time an alarm/warning entry stays active after the object has reached it's normal condition. Common to all alarms/warnings. - Unit 10 ms - Minimum …
1.3.6.1.4.1.3715.99.1.3.11ScalarcontrolTrapDelayread-writeoptionalThe time before a trap is sent after an alarm is detected. - Unit 10 ms - Minimum value 10 (100 ms) - Maximum value 6000 (60 seconds) - Default value 500 (5 se…
1.3.6.1.4.1.3715.99.1.4NodeelementProductKey
1.3.6.1.4.1.3715.99.1.4.4ScalarproductKeyNumberOfKeysread-onlyoptionalNumber of product keys supported by the device.
1.3.6.1.4.1.3715.99.1.4.5TableproductKeyTablenot-accessiblemandatory
1.3.6.1.4.1.3715.99.1.4.5.1RowproductKeyEntrynot-accessiblemandatory
1.3.6.1.4.1.3715.99.1.4.5.1.1ColumnproductKeyIndexread-onlymandatoryProduct key index.
1.3.6.1.4.1.3715.99.1.4.5.1.2ColumnproductKeyValueread-writemandatoryProduct key value.
1.3.6.1.4.1.3715.99.1.4.5.1.3ColumnproductKeyMaskread-onlymandatoryProduct key mask.
1.3.6.1.4.1.3715.99.1.4.5.1.4ColumnproductKeyStatusread-onlymandatoryProduct key status: 1(keyInvalid) = the key is invalid or missing 2(keyValid) = the key is valid
1.3.6.1.4.1.3715.99.1.4.5.1.5ColumnproductKeyCipherread-onlymandatoryCipher method supported by this key: 1(cipherOther) = other ciphering is used 2(cipherBlowFish) = BlowFish ciphering is used 3(cipherXXTEA) = XXTEA ciphering i…
1.3.6.1.4.1.3715.99.1.4.5.1.6ColumnproductKeyNumberOfFeaturesread-onlymandatoryNumber of features available with this key.
1.3.6.1.4.1.3715.99.1.4.6TableproductKeyFeatureTablenot-accessiblemandatory
1.3.6.1.4.1.3715.99.1.4.6.1RowproductKeyFeatureEntrynot-accessiblemandatory
1.3.6.1.4.1.3715.99.1.4.6.1.1ColumnproductKeyFeatureIndexread-onlymandatoryFeature index (second index).
1.3.6.1.4.1.3715.99.1.4.6.1.2ColumnproductKeyFeatureNameread-onlymandatoryA human-readable description of the feature.
1.3.6.1.4.1.3715.99.1.4.6.1.3ColumnproductKeyFeatureEnableread-onlymandatoryStatus of the feature: 1(featureDisable) = the feature si disabled in this device 2(featureEnable) = the feature is enabled in this devices
1.3.6.1.4.1.3715.99.1.4.6.1.4ColumnproductKeyFeatureExpirationTimeread-onlymandatoryNumber of days left before the feature expires. A zero value means infinite validity time. This object has a meaning only if the feature is enabled (productKey…
1.3.6.1.4.1.3715.99.2Nodemodule
1.3.6.1.4.1.3715.99.2.1NodemoduleInformation
1.3.6.1.4.1.3715.99.2.1.1TablemoduleTablenot-accessiblemandatoryThis table lists basic module identification and configuration data of modules installed inside the managed element. The first row in the table list informatio…
1.3.6.1.4.1.3715.99.2.1.1.1RowmoduleEntrynot-accessiblemandatory
1.3.6.1.4.1.3715.99.2.1.1.1.1ColumnmoduleIdread-onlymandatoryAn unique module index identifying the (physical) modules inside the network element. The exact conjunction between the index and the physical modules depends …
1.3.6.1.4.1.3715.99.2.1.1.1.2ColumnmoduleNameread-writeoptionalThe identification name ('aliasname') of the module.
1.3.6.1.4.1.3715.99.2.1.1.1.3ColumnmoduleHwTyperead-onlymandatoryThe hardware type name of the module.
1.3.6.1.4.1.3715.99.2.1.1.1.4ColumnmoduleRackNoread-writeoptionalRack number of the module. This can be used to identify the physical position of the module in the case where the agent manages modules that are in several rac…
1.3.6.1.4.1.3715.99.2.1.1.1.5ColumnmoduleSlotNoread-writeoptionalSlot number of the module (within rack).
1.3.6.1.4.1.3715.99.2.1.2TablemoduleDetailTablenot-accessiblemandatoryThis table lists detailed module data of modules installed inside the element. The first row in the table list information about the element itself. If the ele…
1.3.6.1.4.1.3715.99.2.1.2.1RowmoduleDetailEntrynot-accessiblemandatory
1.3.6.1.4.1.3715.99.2.1.2.1.1ColumnmoduleMacAddressread-onlyoptionalModule MAC address. If the MAC address is unknown '00.00.00.00.00.00' is returned.
1.3.6.1.4.1.3715.99.2.1.2.1.2ColumnmoduleBusAddressread-onlyoptionalModule bus address.
1.3.6.1.4.1.3715.99.2.1.2.1.3ColumnmoduleAppDateread-onlymandatoryModule application software date.
1.3.6.1.4.1.3715.99.2.1.2.1.4ColumnmoduleAppVersionread-onlymandatoryModule application software version. If software version is undefined, then zero length string is returned.
1.3.6.1.4.1.3715.99.2.1.2.1.5ColumnmoduleBiosDateread-onlymandatoryModule BIOS date.
1.3.6.1.4.1.3715.99.2.1.2.1.6ColumnmoduleBiosVersionread-onlymandatoryModule BIOS version. If bios version is undefined, a zero length string is returned.
1.3.6.1.4.1.3715.99.2.1.2.1.7ColumnmoduleHwSerialNumberread-onlymandatoryModule serial number.
1.3.6.1.4.1.3715.99.2.1.2.1.8ColumnmoduleHwVersionread-onlymandatoryModule hardware version.
1.3.6.1.4.1.3715.99.2.2NodemoduleStatus
1.3.6.1.4.1.3715.99.2.2.1TablemoduleStatusTablenot-accessiblemandatoryThis table contains status objects for modules inside the network element.The first row in the table lists information about the host module. If the element is…
1.3.6.1.4.1.3715.99.2.2.1.1RowmoduleStatusEntrynot-accessiblemandatoryRow in moduleStatusTable. The index is moduleId from the moduleTable. Row in this table exist only if there is a row with the same moduleId in the moduleTable.
1.3.6.1.4.1.3715.99.2.2.1.1.1ColumnstatusResetCauseread-onlymandatoryReason for the last reset. If the reason is unknown, the value is reasonUnknown(1). If the device makes self reset and it can detect it, then value is reasonSe…
1.3.6.1.4.1.3715.99.2.2.1.1.2ColumnstatusRunningSwImageread-onlymandatoryCurrently running software image number. Bios is 0, applications are numbered from 1..n, where n is the maximum image number.
1.3.6.1.4.1.3715.99.2.2.1.1.3ColumnstatusInternalTemperatureread-onlymandatoryDevice temperature, unit 0.1 deg C. Value is zero (0), if temperature is not available.
1.3.6.1.4.1.3715.99.2.2.1.1.4ColumnstatusLidStatusread-onlyoptionalCurrent lid status detected by the device. May or may not be the same variable as the elementLidStatus.
1.3.6.1.4.1.3715.99.2.2.1.1.5ColumnstatusRestartCounterread-onlyoptionalThis objects counts the number of restarts of the module. A start can be a cold start or a warm start.
1.3.6.1.4.1.3715.99.2.3NodemoduleControl
1.3.6.1.4.1.3715.99.2.3.1TablemoduleControlTablenot-accessibleoptionalThis table contains common control commands for all the modules inside the element.
1.3.6.1.4.1.3715.99.2.3.1.1RowmoduleControlEntrynot-accessibleoptional
1.3.6.1.4.1.3715.99.2.3.1.1.1ColumncontrolLedUsageread-writeoptionalA variable to instruct how device LED's behave when the lid is closed.
1.3.6.1.4.1.3715.99.2.3.1.1.2ColumncontrolMarkStateread-writeoptionalA variable to instruct the device to start and stop showing mark (blinking module LED). On read requests returns the current mark state.
1.3.6.1.4.1.3715.99.2.3.1.1.3ColumncontrolResetread-writeoptionalOn write requests this object commands the module to reset itself. If softReset(3) or hardReset(2) can not be performed, then BAD VALUE error is returned. On r…
1.3.6.1.4.1.3715.99.2.3.1.1.4ColumncontrolTempLimitHiHiread-writeoptionalModule temperature HiHi (high alarm) limit in 0.1 degC.
1.3.6.1.4.1.3715.99.2.3.1.1.5ColumncontrolTempLimitHiread-writeoptionalModule temperature Hi (high warning) limit in 0.1 degC.
1.3.6.1.4.1.3715.99.2.3.1.1.7ColumncontrolTempLimitLoread-writeoptionalModule temperature Lo (low warning) limit in 0.1 degC.
1.3.6.1.4.1.3715.99.2.3.1.1.8ColumncontrolTempLimitLoLoread-writeoptionalModule temperature LoLo (low alarm) limit in 0.1 degC.
1.3.6.1.4.1.3715.99.2.3.1.1.9ColumncontrolTempDeadBandread-writeoptionalModule temperature alarm/warning deadband in 0.1 degC. Common to all limit values (LoLo, Lo, Hi, HiHi). The deadband defines the difference between the 'ON' li…
1.3.6.1.4.1.3715.99.2.3.1.1.10ColumncontrolInternalAppAccessread-writeoptionalThis object defines whether the internal controller application is able to access the module parameters. This corresponds to the BXX module setting 'Allow Func…
1.3.6.1.4.1.3715.99.2.3.1.1.11ColumncontrolLocalAccessread-writeoptionalThis object defines whether the local user interface (buttons, knobs etc.) is enabled or disabled. Values: 1 = disabled, local UI is locked 2 = enabled, local …
1.3.6.1.4.1.3715.99.2.3.2TablemoduleSWUpdateTablenot-accessibleoptionalA table of software update control objects.
1.3.6.1.4.1.3715.99.2.3.2.1RowmoduleSWUpdateEntrynot-accessibleoptional
1.3.6.1.4.1.3715.99.2.3.2.1.1ColumnsWUpdateControlread-writeoptionalWriting value updateStart(4) commands the module to run a software update. The software image location and file name are specified in sWUpdateURL and sWUpdateF…
1.3.6.1.4.1.3715.99.2.3.2.1.2ColumnswUpdateURLread-writeoptionalThe URL where the software image can be downloaded. Format e.g. TFTP:\\downloads\swupdate\.
1.3.6.1.4.1.3715.99.2.3.2.1.3ColumnsWUpdateFileNameread-writeoptionalFile name of the software image file to be downloaded.
1.3.6.1.4.1.3715.99.2.3.2.1.4ColumnsWUpdateStatusread-onlyoptionalDescription of the software update result. After successful update this object should return a string 'Software updated successfully on <date and time>'. If th…
1.3.6.1.4.1.3715.99.2.4NodemoduleRegistry
1.3.6.1.4.1.3715.99.2.4.1TablemoduleSizeOfTablenot-accessibleoptionalThis table defines maximum number of entries in the registry tables. All the registry tables have fixed size defined in this table.
1.3.6.1.4.1.3715.99.2.4.1.1RowmoduleSizeOfEntrynot-accessibleoptional
1.3.6.1.4.1.3715.99.2.4.1.1.1ColumnsizeOfRegistryread-onlymandatoryMax number of entries in the registryTable. The entries in the registryTable are numbered from 1..sizeofRegistry.
1.3.6.1.4.1.3715.99.2.4.1.1.2ColumnsizeOfRepairlogread-onlyoptionalMax number of entries in the repairlogTable. First entry (oldest entry) is deleted, when a new entry is added and the table is full.
1.3.6.1.4.1.3715.99.2.4.1.1.3ColumnsizeOfNotebookread-onlyoptionalMax number of entries in the notebookTable. The lines in the notebookTable are numbered from 1..sizeofNotebook.
1.3.6.1.4.1.3715.99.2.4.2TablemoduleRegistryTablenot-accessibleoptionalThis table lists user data for all modules installed inside the element. Table is indexed by the moduleId and regIndex. regIndex can have values 1..sizeofRegis…
1.3.6.1.4.1.3715.99.2.4.2.1RowmoduleRegistryEntrynot-accessibleoptional
1.3.6.1.4.1.3715.99.2.4.2.1.1ColumnregIndexread-onlyoptionalA second index to registryTable. Can have values 1..sizeofRegistryTable.
1.3.6.1.4.1.3715.99.2.4.2.1.2ColumnregNameread-writeoptionalDescriptive name for the parameter. The agent is allowed to limit the length of the name. Minimum length of eight characters must be supported. Writing empty s…
1.3.6.1.4.1.3715.99.2.4.2.1.3ColumnregValueread-writeoptionalTextual information describing the parameter information. The agent is allowed to limit the length of the name. Minimum length of eight characters must be supp…
1.3.6.1.4.1.3715.99.2.4.3TablemoduleRepairLogTablenot-accessibleoptionalThis table contains repair history entries for modules in the element. The table is indexed with moduleId and repairLogDate. The table can have sizeofRepairlog…
1.3.6.1.4.1.3715.99.2.4.3.1RowmoduleRepairLogEntrynot-accessibleoptionalRow entry in RepairLogTable. Note that it uses double index: moduleId repairIndex. that uniquely identify each log entry. Rows for particular module exist only…
1.3.6.1.4.1.3715.99.2.4.3.1.1ColumnrepairIndexread-onlyoptionalRow number of the Repairlog entry. Can have values between 1..sizeOfRepairlog. This field is a second index to moduleRepairLogTable.
1.3.6.1.4.1.3715.99.2.4.3.1.2ColumnrepairDateread-writeoptionalDate of this repair entry formatted as CCYY-MM-DD.
1.3.6.1.4.1.3715.99.2.4.3.1.3ColumnrepairReasonCoderead-writeoptionalRepair code for this entry.
1.3.6.1.4.1.3715.99.2.4.3.1.4ColumnrepairNameCoderead-writeoptionalRepairer name code (initials) for this entry.
1.3.6.1.4.1.3715.99.2.4.3.1.5ColumnrepairCommentread-writeoptionalComment of the repair event. The agent is allowed to truncate the length of the comment, if it is too long to internal storage.
1.3.6.1.4.1.3715.99.2.4.4TablemoduleNotebookTablenot-accessibleoptionalNotebook is a free text area for manager or serviceman notes. It is divided into 50 character long character blocks or lines. Each line is an entry in the note…
1.3.6.1.4.1.3715.99.2.4.4.1RowmoduleNotebookEntrynot-accessibleoptional
1.3.6.1.4.1.3715.99.2.4.4.1.1ColumnnotebookLineNumberread-onlyoptionalThe line number of the notebookTextLine. The number must be in between 1..sizeofNotebook. inclusive. Numbers should be used consecutively.
1.3.6.1.4.1.3715.99.2.4.4.1.2ColumnnotebookLineTextread-writeoptionalText field for storing notes about the module.